Loading...
HomeMy WebLinkAbout10-E7-08DRAWING NO.: DRAWN BY: DATE: SHEET TITLE: PROJECT TITLE: COLLEGETOWN TERRACE APARTMENTS ITHACA, NY NOVARR MACKESEY DEVELOPMENTPROFESSIONAL LICENSE NUMBER: NEW YORK STATE SEAL: a r c h i t e c t s ikon.5 PROJECT NO.:P58.00 VERSIONS NO. DATE DESCRIPTION CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL ENGINEER: LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER: 12923 JULY 1, 2011 1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS KEY PLAN 2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS ADDENDUM - 1 ELECTRICAL DIAGRAMS KSO E7.08 GENERAL NOTES: A. REFER TO DATA RACK DIAGRAMS FOR RACK REQUIREMENTS. NO SCALE TYPICAL DATA RACK DIAGRAMS1 TYPICAL DATA RACK LAYOUT BLANK FILLER FIBER PATCH PANELS BLANK FILLER 48-PORT PATCH PANEL 24-PORT PATCH PANEL COMMUNICATIONS ROOM GENERAL NOTES: A. PROVIDE 10% SPARE RACK CAPACITY BASED ON THE AMOUNT OF RACK CAPACITY UTILIZED BY THE PATCH PANELS PROVIDED. B. PROVIDE A MINIMUM SPARE CAPACITY OF 10 PERCENT IN THE INSTALLED PATCH PANELS. C. PROVIDE QUANTITY OF PATCH PANELS TO ACCOMMODATE ALL BUILDING OUTLETS. D. PROVIDE CABLE MANAGEMENT AND GROUNDING. E. COORDINATE WORK WITH OWNERS DATA SYSTEM SERVICE PROVIDER (LIGHTLINK DATA SYSTEMS) PRIOR TO COMMENCEMENT OF WORK. TO GROUNDING ELECTRODE SYSTEM GROUND BAR 20' SERVICE LOOP FIBER OPTIC CABLE MULTIPLE CAT 5E CABLES TO DATA OUTLETS REFER TO FLOOR PLANS FOR QUANTITY/LOCATIONS OF DATA OUTLETS MINIMUM #6 CU GROUND WALL MOUNTED DATA RACK 120V TVSS DUPLEX RECEPTACLE ON DEDICATED CIRCUIT, TYPICAL WALL MOUNTED, 48" HIGH AND 19" WIDE EQUIPMENT RACK FIBER OPTIC AND CAT5E PATCH PANELS, TYPICAL 1 KEYED NOTES: CAT5E TO RJ-45 OUTLET, TYPICAL. PROVIDE ONE 4-PR CAT5E TO EACH DATA SYSTEM OUTLET. REFER TO PLANS FOR QUANTITY AND LOCATIONS. REFER TO DATA SYSTEM DIAGRAMS FOR GENERAL LAYOUT REQUIREMENTS. DUCTBANK AND HAND HOLES SHOWN FOR REFERENCE AND NOT USED FOR ACTIVE DATA SERVICE. 2 3 NO SCALE DATA SYSTEM CABLING DIAGRAM2 CPB-5 HH-1 HH-6 1 1 1 111 CPB-1 HH-5 HH-7HH-6 CPB-2CPB-3 CPB-4 HH-2 222 2 2 2 BUILDING 2.0 MDF-21 BUILDING 1 MDF-1 BUILDING 4.2 MDF-42 BUILDING 4.1 MDF-41 BUILDING 2.4 MDF-24 BUILDING 4.3 MDF-43 CASA ROMA MAIN IT ROOM HH-3 BLANK FILLER KEYED NOTES: RACK LAYOUT IS GENERIC AND INTENDED TO SHOW GENERAL POSITIONING OF RACK MOUNTED EQUIPMENT. PROVIDE QUANTITY AND CAPACITY OF FIBER OPTIC AND CAT5E PATCH PANELS REQUIRED FOR EACH BUILDINGS NEEDS FOR A COMPLETE SYSTEM. 1 RACK UNIT EMPTY SPACE FOR OWNERS SWITCHING EQUIPMENT. TO FLOOR ABOVE, IF PRESENT NO SCALE TYPICAL TIME WARNER SERVICE DISTRIBUTION DIAGRAM CATV SERVICE ENTRANCE CABLE BY SERVICE PROVIDER TV TIME WARNER BACKBOARD CATV SERVICE ENTRANCE EQUIPMENT BY TIME WARNER TELECOMMUNICATIONS BACKBOARD RG6 COAX GENERAL NOTES: A. PROVIDE GROUNDING PER SPECIFICATIONS AND DETAILS. B. COORDINATE ENTIRE INSTALLATION WITH TIME WARNER. C. PROVIDE ALL CABLING FROM END USER OUTLET TO TIME WARNER SERVICE EQUIPMENT. PROVIDE ALL TERMINATIONS AT END USER OUTLET. REFER TO FLOOR PLANS FOR QUANTITY/LOCATIONS 3 2 2 2 RACK UNIT WIRE MANAGEMENT EMPTY SPACE 48-PORT PATCH PANEL BLANK FILLER 2 RACK UNIT WIRE MANAGEMENT EMPTY SPACE 2 RACK UNIT WIRE MANAGEMENT EMPTY SPACE 2 2 2 QUARRY ARMS MAIN IT ROOM DATA CABLE SCHEDULE NOTES: 1. 4 SETS (12 ST MM CABLE) TO SERVE BUILDING 4 GROUP. PROVIDE EACH BUILDING WITH 1 SET. 2. 6 SETS (12 ST MM CABLE) TO SERVE BUILDINGS AS FOLLOWS: * 4 SETS TO BUILDING 4 GROUP PER CABLE SCHEDULE NOTE 1. * 1 SET TO SERVE CASA ROMA. * 1 SET TO SERVE QUARRY ARMS. 3. 2 SETS (12 ST MM CABLE) TO SERVE BUILDINGS AS FOLLOWS: * 1 SET TO SERVE CASA ROMA. * 1 SET TO SERVE QUARRY ARMS. 4. ROUTE 1 SET (12 ST MM CABLE) FROM CASA ROMA TO QUARRY ARMS VIA AN EXISTING DUCT BETWEEN BUILDING COMMUNICATION ROOMS. DATA CABLE SCHEDULE CIRCUIT DESIGNATION CABLE TYPE NOTES CAT5E 4-PR UTP 12 ST MM FIBER OPTIC CABLE 4 SETS (12 ST MM FIRBER OPTIC CABLE) 1 6 SETS (12 ST MM FIRBER OPTIC CABLE) 2 2 SETS (12 ST MM FIRBER OPTIC CABLE) 3 12 ST MM FIBER OPTIC CABLE 4 2 2 2 2 2 2 2 2 2