Loading...
HomeMy WebLinkAbout10-E7-01DRAWING NO.: DRAWN BY: DATE: SHEET TITLE: PROJECT TITLE: COLLEGETOWN TERRACE APARTMENTS ITHACA, NY NOVARR MACKESEY DEVELOPMENTPROFESSIONAL LICENSE NUMBER: NEW YORK STATE SEAL: a r c h i t e c t s ikon.5 PROJECT NO.:P58.00 VERSIONS NO. DATE DESCRIPTION CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL ENGINEER: LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER: 12923 JULY 1, 2011 1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS KEY PLAN 2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS ADDENDUM - 1 NO SCALE BUILDING 2.4 - POWER ONE-LINE DIAGRAM2 ELECTRICAL ONE-LINE DIAGRAM KSO E7.01 PAD-MOUNT TRANSFORMER BY UTILITY COMPANY. TRANSFORMER PAD BY ELECTRICAL CONTRACTOR. REFER TO PAD-MOUNT TRANSFORMER DETAILS. REFER TO CIVIL DRAWINGS FOR PRIMARY SERVICE REQUIREMENTS. BUILDING STEEL INCOMING WATER MAIN GROUND BUS CONCRETE ENCASED ELECTRODE #4/0 COPPER PER NEC TABLE 250.66 TO ELECTRODE GROUND GRID. SEE ELECTRODE GROUND GRID DETAIL. NO SCALE BUILDING 1 - POWER ONE-LINE DIAGRAM1 PAD-MOUNT TRANSFORMER BY UTILITY COMPANY. TRANSFORMER PAD BY ELECTRICAL CONTRACTOR. REFER TO PAD-MOUNT TRANSFORMER DETAILS. REFER TO CIVIL DRAWINGS FOR PRIMARY SERVICE REQUIREMENTS. BUILDING STEEL INCOMING WATER MAIN GROUND BUS CONCRETE ENCASED ELECTRODE #4/0 COPPER PER NEC TABLE 250.66 TO ELECTRODE GROUND GRID. SEE ELECTRODE GROUND GRID DETAIL. FEEDER SCHEDULE CIRCUIT CONDUCTOR AND CONDUIT NOTES DESIGNATION SIZE AND QUANTITY 1 4#2, #8G, 1-1/4"C 2 3#1/0, #4G, MC AL 3 3#2/0, #4G, MC AL 4 3#3/0, #4G, MC AL 5 3#4/0, #2G, MC AL 6 4#8, #10G, 3/4"C 7 2 SETS (4#500, 4"C) 8 4#1/0, #6G, 2"C 9 4 SETS (4#350, 3"C) 10 2 SETS (4"C WITH PULL ROPE) 11 4#500, #2G, 4"C 12 4 #3/0, #6G, 2"C 13 14 15 16 17 18 19 20 50A 3P 50A 3P 50A 3P MC10 - 800A, 208/120V, 3 PHASE, 4 WIRE, 18K AIC MC24 - 600A, 208/120V, 3 PHASE, 4 WIRE, 25K AIC GENERAL NOTES: A. PHASE BALANCE TENANT BREAKERS SO PHASES AB, BC, AND CA ARE EQUALLY LOADED. B. VERIFY EXACT METER SOCKET TYPE WITH UTILITY BEFORE PROCURING EQUIPMENT. C. FEEDERS ARE COPPER CONDUCTORS UNLESS NOTED OTHERWISE. REFER TO SPECIFICATIONS FOR PERMITTED SUBSTITUTIONS WITH ALUMINUM CONDUCTORS. D. FEEDER NOTED WITH "AL" INDICATE ALUMINUM CONDUCTORS. 2 100A 2P 100A 2P 100A 2P 125A 2P 125A 2P 125A 2P 125A 2P 100A 2P 100A 2P 100A 2P 125A 2P 125A 2P 125A 2P 125A 2P 125A 2P 100A 2P 100A 2P 100A 2P 150A 2P 3P 3P 3P 3P 125A 2P 125A 2P 125A 2P 125A 2P 125A 2P 125A 2P 125A 2P 125A 2P 125A 2P 125A 2P 125A 2P 125A 2P 125A 2P 125A 2P 2 2 2 2 150A 2P