Loading...
HomeMy WebLinkAbout10-E5-03DRAWING NO.: DRAWN BY: DATE: SHEET TITLE: PROJECT TITLE: COLLEGETOWN TERRACE APARTMENTS ITHACA, NY NOVARR MACKESEY DEVELOPMENTPROFESSIONAL LICENSE NUMBER: NEW YORK STATE SEAL: a r c h i t e c t s ikon.5 PROJECT NO.:P58.00 VERSIONS NO. DATE DESCRIPTION CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL ENGINEER: LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER: 12923 KEY PLAN 2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS ADDENDUM - 1 August 10, 2011 ELECTRICAL DETAILS KSO E5.03 TRENCH WIDTH COMPACT BACKFILL TO MATCH SURROUNDING CONDITIONS NO ROCKS, DEBRIS IN BACKFILL UNLESS OTHERWISE NOTED RESTORE SURFACE TO MATCH SITE CONDITIONS PROVIDE MIN. 3" CONCRETE ON ALL SIDES OF CONDUIT CONDUIT: SIZE, MATERIAL AND IDENTIFICATION, AS SPECIFIED MIN. 3" BETWEEN CONDUITS #4 REBARS, 6" O. C. TIED TO CONDUIT SUPPORTS TYPICAL CONDUIT SPACER MAXIMUM 10'-0" O.C. PROVIDE PRECAST BASE AT CONDUIT SPACER BASE, WHERE BOTTOM OF TRENCH IS NOT LEVEL AND UNIFORM #4 REBARS SPIKES FOR HOLD DOWN BAR. MINIMUM 24" GROUND PENETRATION, DRIVEN AT AN APPROXIMATE 25° ANGLE TO CONDUIT RUN HOLD DOWN BAR. PROVIDE QUANTITY TO PREVENT FLOUT-OUT, MAXIMUM 15'-0" O.C. MIN. 3" BETWEEN CONDUITS CONTINUOUS MARKER TAPE GENERAL NOTES: A. REFER TO DUCTBANK SECTION AND/OR ONE-LINE DIAGRAM FOR ACTUAL QUANTITY AND SIZE OF CONDUITS REQUIRED. B. LEAVE PULL ROPE IN ALL SPARES. C. EXCAVATED MATERIAL MEETING SPECIFICATIONS MAY BE USED FOR BACKFILL IN TRENCHES. IN THE EVENT EXCAVATED MATERIAL DOES NOT MEET SPECIFICATIONS, PROVIDE GRANULAR BACKFILL AS SPECIFIED FOR BACKFILL. REMOVE UNSUITABLE MATERIAL FROM SITE. D. UNLESS OTHERWISE NOTED, TOP OF CONDUIT SHALL BE 30" BELOW FINISHED GRADE. FINISH GRADE GENERAL NOTES: A. REINFORCE WITH GRADE 60, #4 BARS @ 6" O. C. E. W. B. 3/4" CHAMFER STRIP, ALL TOP EDGES INCLUDING OPENING. C. TOP AND BOTTOM TO BE SMOOTH FINISH. D. 4000 PSI CONCRETE AT 28 DAYS. E. VERIFY ACTUAL REQUIRED ANCHOR BOLTS, CABLE OPENING AND OVERALL DIMENSIONS AND CONFIGURE ACCORDINGLY. COORDINATE WITH NYSEG. F. PROVIDE PAD AND INSTALLATION PER NYSEG REQUIREMENTS. SUBMIT TO NYSEG FOR APPROVAL PRIOR TO ORDERING. DIMENSIONS IN INCHES 10 DIMENSIONS OF POURED OR PRECAST CONCRETE PADS 75-500 kVA 15 KV 3 PH 78 A 4872 18 CB D E MIN. 1/2" COVER FOR REINFORCING BARS X-FORMER RATING F FRONT A C G E LIFTING LOOP, TYP. D B 6" 6" 3" 2700 WEIGHTS(lbs)F 17 13 G 4 BARS @ 18" TOP ONLY(TYP) TYP TYP 3" NO SCALE PRECAST CONCRETE FLAT PAD4 NO SACLE CONCRETE ENCASED DUCTBANK DETAIL TYPICAL REINFORCED 7NO SACLE TYPICAL SAND BED DUCTBANK DETAIL9 6" DIAMETER SCHEDULE 40 GALVANIZED PIPE. FILL WITH CONCRETE 6" 5'-0" 5'-0" TREAT AND PRIME, THEN THREE COATS OF PAINT, BRIGHT YELLOW OR COLOR AS DIRECTED ROUND OFF FOOTING AT GRADE / PAVEMENT CONCRETE FOOTING 1'-4" DIAMETER ROUND OFF CONCRETE TOP AND PAINT KEYED NOTES: AT TRANSFORMER LOCATIONS, BOND BOLLARD TO 4/0 COPPER CABLE AND BOND CABLE TO GROUND FIELD. THEN PROVIDE CONCRETE. FINISHED GRADE OR PAVING 1 TRENCH WIDTH COMPACT BACKFILL TO MATCH SURROUNDING CONDITIONS NO ROCKS, DEBRIS IN BACKFILL UNLESS OTHERWISE NOTED RESTORE SURFACE TO MATCH SITE CONDITIONS PROVIDE MIN. 3" CONCRETE ON ALL SIDES OF CONDUIT CONDUIT: SIZE, MATERIAL AND IDENTIFICATION, AS SPECIFIED MIN. 3" BETWEEN CONDUITS TYPICAL CONDUIT SPACER MAXIMUM 10'-0" O.C. PROVIDE PRECAST BASE AT CONDUIT SPACER BASE, WHERE BOTTOM OF TRENCH IS NOT LEVEL AND UNIFORM #4 REBARS SPIKES FOR HOLD DOWN BAR. MINIMUM 24" GROUND PENETRATION, DRIVEN AT AN APPROXIMATE 25° ANGLE TO CONDUIT RUN HOLD DOWN BAR. PROVIDE QUANTITY TO PREVENT FLOUT-OUT, MAXIMUM 15'-0" O.C. MIN. 3" BETWEEN CONDUITS CONTINUOUS MARKER TAPE GENERAL NOTES: A. REFER TO DUCTBANK SECTION AND/OR ONE-LINE DIAGRAM FOR ACTUAL QUANTITY AND SIZE OF CONDUITS REQUIRED. B. LEAVE PULL ROPE IN ALL SPARES. C. EXCAVATED MATERIAL MEETING SPECIFICATIONS MAY BE USED FOR BACKFILL IN TRENCHES. IN THE EVENT EXCAVATED MATERIAL DOES NOT MEET SPECIFICATIONS, PROVIDE GRANULAR BACKFILL AS SPECIFIED FOR BACKFILL. REMOVE UNSUITABLE MATERIAL FROM SITE. D. UNLESS OTHERWISE NOTED, TOP OF CONDUIT SHALL BE 30" BELOW FINISHED GRADE. FINISH GRADE NO SACLE CONCRETE ENCASED DUCTBANK DETAIL TYPICAL 5 NO SACLE BOLLARD DETAIL1 KEYED NOTES: MINIMUM 5' SPACING FROM EDGE OF EQUIPMENT ENCLOSURE TO BOLLARD. PROVIDE BOLLARDS MAXIMUM 48" ON CENTER. REFER TO BOLLARD DETAIL FOR CONSTRUCTION.3 2 1 B EDGE OF PAD OR SWITCHGEAR BASE OUTSIDE EDGE OF CONCRETE CURB (TRANSFORMERS ONLY) ELECTRIC EQUIPMENT TYPICAL 3 B B B B 1 B B 2 TYPICAL TYPICAL NO SACLE OUTDOOR PAD MOUNTED EQUIPMENT TYPICAL BOLLARD INSTALLATION AT 2 GENERAL NOTES: A. ALLOW SUFFICIENT SLACK CABLE SO SPLICES CAN BE MADE ABOVE GRADE, OUTSIDE OF HANDHOLE. COIL SPLICE AND SLACK CABLE NEATLY INTO HANDHOLE. B. DO NOT LOCATE HANDHOLES IN VEHICULAR TRAFFIC AREAS. C. INSIDE DIMENSIONS: HT. 48 IN., WIDTH 48 IN., LENGTH 48 IN. 12" OF #2 CRUSHED STONE; EXTEND MINIMUM OF 6" BEYOND OUTSIDE EDGE. MIN. TWO (2) COURSES BRICK. PLACE ADDITIONAL BRICK AS REQUIRED TO BRING FRAME UP TO FINISHED GRADE GROUT FRAME 4" X 10" KNOCKOUTS, TWO (2) ON EACH SIDE SLOPE FINISHED GRADE AWAY FROM COVER FRAME AND COVER UNDISTURBED EARTH GRAVEL REPAIR PAVING OR PLANTING TO MATCH SURROUNDING CONDITIONS HANDHOLE FRAME POWER MANHOLE/ PULLBOX TYPE A TYPE CBBASEA 33-1/2"ROUND 43" 32" FE G 6-1/2"32" COVER X E F D C COVER DESIGNATION G B D 30" NO SCALE PULLBOX FRAME AND COVER6 NO SCALE PULL BOX DETAIL8 TRENCH WIDTH COMPACT BACKFILL TO MATCH SURROUNDING CONDITIONS NO ROCKS, DEBRIS IN BACKFILL CONDUIT: SIZE, MATERIAL AND IDENTIFICATION, AS SPECIFIED MIN. 3" BETWEEN CONDUITS TYPICAL CONDUIT SPACER MAXIMUM 10'-0" O.C. PROVIDE PRECAST BASE AT CONDUIT SPACER BASE, WHERE BOTTOM OF TRENCH IS NOT LEVEL AND UNIFORM MIN. 3" BETWEEN CONDUITS CONTINUOUS MARKER TAPE GENERAL NOTES: A. REFER TO DUCTBANK SECTION AND/OR ONE-LINE DIAGRAM FOR ACTUAL QUANTITY AND SIZE OF CONDUITS REQUIRED. B. LEAVE PULL ROPE IN ALL SPARES. C. EXCAVATED MATERIAL MEETING SPECIFICATIONS MAY BE USED FOR BACKFILL IN TRENCHES. IN THE EVENT EXCAVATED MATERIAL DOES NOT MEET SPECIFICATIONS, PROVIDE GRANULAR BACKFILL AS SPECIFIED FOR BACKFILL. REMOVE UNSUITABLE MATERIAL FROM SITE. D. UNLESS OTHERWISE NOTED, TOP OF CONDUIT SHALL BE 30" BELOW FINISHED GRADE. E. SPACERS AND PRECAST BASE MAY BE DELETED FOR SINGLE TIER DUCTBANK SECTIONS. FINISH GRADE PROVIDE MIN. 3" SAND BED ON ALL SIDES OF CONDUIT UNLESS OTHERWISE NOTED RESTORE SURFACE TO MATCH SITE CONDITIONS TO TELCO. GROUND (IF AVAILABLE) DETAIL A GROUND GRID 2/0 Cu BARE SOFT DRAWN - 19 STRAND CONCRETE FOUNDATION PRIMARY SECONDARY 36" 18" 18"18" 2/0 Cu BARE SOFT DRAWN - 19 STRAND 'C' TYPE COMPRESSION CONNECTOR GROUND CLAMP 8' GROUND ROD 2/0 Cu BARE SOFT DRAWN - 19 STRAND GRADE 12" GROUND CLAMP 8' GROUND ROD PLAN VIEW SECTION VIEW DETAIL A DETAIL B NO SACLE THREE PHASE PADMOUNTED TRANSFORMER NYSEG - GROUNDING PLAN 10 DETAIL B GROUND ROD DETAIL B DETAIL B DETAIL B18" GROUND ROD GROUND ROD GROUND ROD 18" A X 1-1/2" 14750-250015 3 89 5075 17 310021 18