Loading...
HomeMy WebLinkAbout10-E5-02DRAWING NO.: DRAWN BY: DATE: SHEET TITLE: PROJECT TITLE: COLLEGETOWN TERRACE APARTMENTS ITHACA, NY NOVARR MACKESEY DEVELOPMENTPROFESSIONAL LICENSE NUMBER: NEW YORK STATE SEAL: a r c h i t e c t s ikon.5 PROJECT NO.:P58.00 VERSIONS NO. DATE DESCRIPTION CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL ENGINEER: LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER: 12923 JULY 1, 2011 1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS KEY PLAN 2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS ADDENDUM - 1 ELECTRICAL DETAILS KSO E5.02 GENERAL NOTES: A. REPAIR ALL SETTLEMENT. B. MINIMUM TOP SOIL - 6". C. PROVIDE DIRECT BURIED INSTALLATION FOR COMMUNICATION DUCTBANKS AND POWER BRANCH CIRCUITS. D. WHERE ADDITIONAL CABLES ARE CALLED FOR, INCREASE TRENCH WIDTH AND INSTALL CABLES WITH 3" MINIMUM SPACING. E. EXCAVATED MATERIAL MEETING SPECIFICATIONS MAY BE USED FOR BACKFILL IN TRENCHES. IN THE EVENT EXCAVATED MATERIAL DOES NOT MEET SPECIFICATIONS, PROVIDE GRANULAR BACKFILL AS SPECIFIED FOR BACKFILL. REMOVE UNSUITABLE MATERIAL FROM SITE. 30" MINIMUM 3" MINIMUM SPACING FINISH GRADE 3" SAND BED AROUND CONDUIT COMPACT BACKFILL TO MATCH SURROUNDING CONDITIONS NO ROCKS, DEBRIS IN BACKFILL SCHEDULE 80 PVC CONDUIT UNLESS OTHERWISE SHOWN SKID RESISTANT SURFACE HANDHOLE TYPE 12" CRUSHED STONE BELOW HANDHOLE. EXTEND 6" (MIN.) AROUND OUTSIDE EDGE ON HANDHOLE HHL SLOPE FINISH GRADE AWAY FROM COVER. E 18" D DIMENSION CB 12"10"20" A 12" DIMENSION SCHEDULE B C A E D STAINLESS STEEL HEX HEAD BOLT WITH WASHER AND GROMMET PULL SLOT CUSTOM COVER DESIGNATION: POWER, COMMUNICATIONS, CATV, ETC. GENERAL NOTE: A. DO NOT LOCATE IN VEHICULAR TRAFFIC OR SIDEWALK AREAS. CAST POLYMER CONCRETE COVER CAST POLYMER CONCRETE BOX CAST POLYMER CONCRETE HANDHOLE SERVICE ENTRANCE EQUIPMENT STRUCTURAL STEEL #4/0 CU SERVICE ENTRANCE GROUND BUS #4/0 CU CONCRETE ENCASED ELECTRODE IN FLOOR SLAB TYPICAL 3/4"x10' COPPERCLAD GROUND ROD GROUND GRID TYPICAL - EACH BUILDING WATER SERVICE EXOTHERMIC WELD LISTED PIPE CLAMP (WITHIN 5' OF POINT OF ENTRANCE INTO BUILDING) LISTED CLAMP TYPICAL - TWO HOLE COMPRESSION FITTING BOLTED TO BUS TYPICAL - EXOTHERMIC WELD GENERAL NOTES: A. TYPICAL FOR ALL SERVICE ENTRANCE EQUIPMENT. B. PROVIDE SCHEDULE 80 PVC SLEEVES FOR GROUND CONDUCTORS. GROUND CLAMP HUB AND CABLE CLAMP. GROUNDING METER JUMPER AROUND WATER METER AND INSULATING JOINTS. #2 CU #4/0 CU NO SCALE HANDHOLE DETAIL1 NO SCALE ELECTRODE SYSTEM DETAIL SERVICE ENTRANCE GROUNDING 3 NO SACLE MULTIPLE CONDUIT DETAIL TYPICAL DIRECT BURIED IN SANDBED 2 PAVING OR TOPSOIL TO MATCH SITE CONDITIONS MARKING TAPE INSULATED MOUNTING BRACKET 1/4" COPPER GROUND BAR NO SCALE GROUND BAR DETAIL GENERAL NOTES: A. PROVIDE #4 GREEN INSULATED GROUND WIRE TO MAIN SERVICE GROUND. B. PROVIDE GROUND BAR IN EACH COMMUNICATION ROOM/CLOSET. REFER TO FLOOR PLANS FOR LOCATIONS AND QUANTITIES. C. PROVIDE LONG BARREL, INDENT TYPE LUGS FOR GROUND CONNECTION. 4 #4 CU COMM ROOM GROUND BAR 2 HH 34"26"23"38"40" NOTE 1 NOTES: 1. LIGHTING HANDHOLES HHL ARE NOT SHOWN ON SITE PLANS. 2 FIRE ALARM RISER GENERAL NOTES: A. THE FIRE ALARM RISER DIAGRAM IS DIAGRAMMATIC ONLY AND IS NOT INTENDED TO SHOW EACH DEVICE OR EXACT CONNECTIONS. OBTAIN WIRING DIAGRAM FROM SYSTEM VENDOR FOR ALL DEVICES AND COMPONENTS REQUIRED TO MEET SPECIFICATIONS. THE ACTUAL FIELD INSTALLATION WILL REQUIRE PULL BOXES, OFFSETS, OUTLET BOXES & OTHER RELATED ELECTRIC WORK TO PROVIDE THE PROPER INSTALLATION. B. ALL CONDUCTOR WIRING SHALL BE PERMANENTLY IDENTIFIED AND LABELED IN ACCORDANCE WITH THE SPECIFICATIONS. C. SLC CIRCUITS: #18 TP (SHIELDED) FPL CABLE STROBE CIRCUITS (NAC): 2-#12 FPL CABLE 24VDC AUX. POWER: 2-#12 FPL CABLE D. NOT ALL FIRE ALARM DEVICES ARE SHOWN OR INDICATED. DEVICES ARE REPRESENTATIVE ONLY. REFER TO APPLICABLE FLOOR PLANS FOR DEVICE LOCATIONS, TYPES AND QUANTITIES. E. MAIN FIRE ALARM CIRCUIT WILL RUN IN HALLWAY AND IS PERMISSIBLE TO T-TAP BRANCH CIRCUITS TO EACH APARTMENT FROM MAIN CIRCUIT. F. PROVIDE NAC PANELS AND TERMINAL EQUIPMENT CABINETS AS REQUIRED. M. PROVIDE FIRE ALARM SYSTEM CONNECTION TO ELEVATOR SHUNT TRIP DISCONNECT SWITCHES. FACP 120V 20A-1P 1 FPHP TS 2 KEYED NOTES: PROVIDE TWO 4-PR CAT5E TELEPHONE LINES FROM BUILDING TELEPHONE SYSTEM BACKBOARD TO FIRE ALARM CONTROL PANEL. PROVIDE SUPERVISORY CONNECTION TO FIRE PROTECTION HEAT TRACE CONTROL PANEL. TERMINAL EQUIPMENT CABINET. ADDRESSABLE MONITOR MODULE. 1 2 24VDC AUX POWER 24VDC AUX POWER 24VDC AUX POWER TEC 120V 20A-1P FPHP TS 2 24VDC AUX POWER 24VDC AUX POWER 24VDC AUX POWER TEC 120V 20A-1P FPHP TS 2 24VDC AUX POWER 24VDC AUX POWER 24VDC AUX POWER FACP 120V 20A-1P 1 FPHP TS 2 24VDC AUX POWER 24VDC AUX POWER 24VDC AUX POWER NO SCALE BUILDINGS 1, 2.4, 4.1, 4.2 & 4.3 FIRE ALARM SYSTEM RISER DIAGRAM 6 NO SCALE BUILDING 2.0, 2.1, 2.2 & 2.3 FIRE ALARM SYSTEM RISER DIAGRAM 5 3 4 33 4 TYPICAL 4 TYPICAL 4 TYPICAL