Loading...
HomeMy WebLinkAbout10-E5-01DRAWING NO.: DRAWN BY: DATE: SHEET TITLE: PROJECT TITLE: COLLEGETOWN TERRACE APARTMENTS ITHACA, NY NOVARR MACKESEY DEVELOPMENTPROFESSIONAL LICENSE NUMBER: NEW YORK STATE SEAL: a r c h i t e c t s ikon.5 PROJECT NO.:P58.00 VERSIONS NO. DATE DESCRIPTION CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL ENGINEER: LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER: 12923 JULY 1, 2011 1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS KEY PLAN 2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS ADDENDUM - 1 NO SACLE ELEVATOR SHUTDOWN DETAIL1 ELECTRICAL DETAILS KSO E5.01 GENERAL NOTES: A. SHUNT TRIP WITH COIL CLEARING CONTACT RATED 24V DC. B. PROVIDE SEPARATE 20A FUSED CIRCUIT FROM FIRE ALARM PANEL FOR EACH SHUNT TRIP. C. BREAKER SIZE PER DRAWINGS - PROVIDE ACCORDING TO QUANTITY AND SIZE OR ELEVATOR CIRCUITS. HOUSE PANEL TO ELEVATOR HOISTWAY EQUIPMENT. REFER TO ELEVATOR DETAIL. TYPICAL FOR HEAT DETECTORS LOCATED IN THE ELEVATOR PIT AND HOISTWAY, EACH ELEVATOR. WIRE CONTACTS IN PARALLEL.TO MAIN FIRE ALARM PANEL (INITIATING) TO MAIN FIRE ALARM PANEL (24VDC) 2#12, 1/2"C OUTLET/SUPPORT BRACKET - ERICO/CADDY FASTENER STANDARD 1 GANG, RAISED OUTLET BOX COVERS - FOR DUPLEX RECEPTACLE. GENERAL NOTES: A. FOR BACK-TO-BACK OUTLET LOCATIONS IN ADJOINING ROOMS, STAGGER BOXES LOCATION TO ADJACENT CAVITIES IN WALL TO MINIMIZE SOUND TRANSMISSION. B. FROM EACH VOICE, DATA, AND TV OUTLET LOCATION, PROVIDE 3/4" MIN. SIZE EMT RACEWAY, LARGER IF REQUIRED FOR CABLE/CONNECTOR, CONCEALED IN WALL CONSTRUCTION, TO NEAREST ACCESSIBLE CEILING SPACE. C. PROVIDE ALL PROVISIONS AS REQUIRED FOR A COMPLETE SYSTEM. STANDARD 1 GANG, RAISED OUTLET BOX COVERS - FOR VOICE/DATA/TV OUTLETS. BEHIND BRACKET. STANDARD 4''SQ. x 1-1\2"D. ELECTRICAL BOX. TYPICAL FOR VOICE, DATA, TV AND DUPLEX RECEPTACLES. METAL STUDS- TYPICALLY 16'' o.c. LC NOMINAL 8 FOOT CEILING PLANE FA SYSTEM A/V DEVICE ILLUMINATED EXIT SIGN TOP OF PANELBOARD BACKBOX FA SYSTEM PULL STATION DOOR OPENING WALL MOUNTED INTERCOM LIGHTING CONTROL WITHIN 6" FINISHED FLOOR ELEVATION STANDARDCOUNTERPOWER, DATA, TV OR VOICE 72"EQUAL EQUAL COUNTER TOP 80" TO BOTTOM48"STRIKE SIDE45" FORPOWER, DATA OR VOICE 60"DISCONNECT SWITCH OR STARTER 1FO 9 11 AT TOP OF HOISTWAY H 3 54 8 TO PANEL SIMPLEX RECEPTACLE FOR SUMP PUMP GFCI 1 KEYED NOTES: COMPACT FLUORESCENT FIXTURE WITH LAMP SHIELD. DO NOT WIRE ON LOADSIDE OF RECEPTACLE. CIRCUITRY PROVIDED BY ELEVATOR CONTRACTOR HEAVY-DUTY, FUSED DISCONNECT SWITCH, COORDINATE VOLTAGE, PHASE, AND FUSE SIZE WITH ELEVATOR SUPPLIER. WIRE COMPLETE TO ELEVATOR CONTROLLER. DISCONNECT SWITCH SHALL BE SHUNT TRIP TYPE. UPON ACTIVATION OF HEAT DETECTOR IN HOISTWAY, SHUNT TRIP DISCONNECT SHALL OPERATE/OPEN IN ORDER TO SHUT DOWN ELEVATOR BEFORE SPRINKLERS ACTIVATE. 24V SHUNT TRIP COIL. HEAVY-DUTY, FUSED DISCONNECT SWITCH, 240 VOLT, 30 AMP (WITH 20 AMP FUSE, VERIFY WITH ELEVATOR SUPPLIER), SINGLE PHASE WITH SOLID NEUTRAL FOR ELEVATOR CAR LIGHTS AND VENTILATION FAN. WIRE COMPLETE TO ELEVATOR CONTROLLER. HEAVY DUTY, FUSED DISCONNECT SWITCH, 240 VOLTS, 30 AMPS (WITH 20 AMP FUSE, VERIFY WITH ELEVATOR SUPPLIER), SINGLE PHASE WITH SOLID NEUTRAL FOR CAR HEATING AND AIR CONDITIONING. WIRE COMPLETE TO ELEVATOR CONTROLLER. PROVIDE A 3/4" CONDUIT WITH CAT5E CABLE FROM THE MAIN TELEPHONE TERMINAL BOARD TO ELEVATOR CONTROLLER. ELEVATOR FEEDER. REFER TO ELECTRIC EQUIPMENT AND CONTROL SCHEDULE. SMOKE DETECTOR LOCATED IN ELEVATOR LOBBY, ON EACH FLOOR. CONNECT TO FIRE ALARM SYSTEM AND ELEVATOR RECALL SYSTEM. SMOKE DETECTOR LOCATED AT TOP OF ELEVATOR HOISTWAY. CONNECT TO SMOKE HATCH (IF PRESENT), FIRE ALARM SYSTEM AND ELEVATOR RECALL SYSTEM. NOT USED FIXED TEMPERATURE HEAT DETECTOR, 135°F, AT TOP OF ELEVATOR HOISTWAY. LOCATE WITHIN TWO FEET OF SPRINKLER HEAD. CONNECT TO FIRE ALARM SYSTEM AND ELEVATOR SHUTDOWN. PROVIDE CONTROL MODULES FOR SHUTDOWN. PROVIDE CONTROL MODULE, PROGRAMMING AND CONNECTION TO ELEVATOR TO FACILITATE ILLUMINATION OF ELEVATOR CAB HIGH HAT ALARM WHEN ANY FIRE DETECTION DEVICE IN MACHINE ROOM OR HOISTWAY GOES INTO ALARM. PROVIDE MONITOR MODULE TO MONITOR PRESENCE OF SHUNT TRIP CONTROL POWER. CONNECT TO FIRE ALARM SYSTEM. PROVIDE NEMA 1 CABINET WITH RELAYS FOR DESIGNATED LEVEL RECALL, ALTERNATE LEVEL RECALL, VISUAL WARNING (HIGH HAT ALARM) AND ELEVATOR SHUTDOWN. LOCATE WITHIN 3 FEET OF ELEVATOR CONTROLLER. PROVIDE WIRING COMPLETE TO ELEVATOR CONTROLLER. 10 2 3 4 5 6 7 8 9 GENERAL NOTES: A. LAYOUT IS GENERAL AND IS INTENDED TO SHOW ITEMS OF WORK AND NOT LOCATIONS OR SPACE CONFIGURATION. ACTUAL LOCATION OF ITEMS TO BE COORDINATED WITH ACTUAL LAYOUT OF ELEVATOR EQUIPMENT, SPACES, AND WITH CODE ENFORCEMENT AUTHORITY HAVING JURISDICTION. B. ELEVATOR MACHINE IS LOCATED IN HOISTWAY. THERE IS NO ELEVATOR MACHINE ROOM. 11 12 12 TO PANEL 13 6 13 14 ELEVATOR CONTROLLER 14 NO SCALE RECEPTACLE & VOICE/DATA/TV OUTLETS INSTALLATION @ SIDE-BY-SIDE 2 NO SACLE ELEVATOR DETAIL (WITH BUILDING SPRINKLER SYSTEM)6 NO SCALE PIT PLANC NO SCALE LOBBY PLANB NO SCALE SHAFT PLANA NO SACLE TYPICAL ROUGHING HEIGHTS FOR ELECTRIC WORK5 CONDUITS TO STUB UP WITHIN LUMINAIRE BASE D 12" PEA GRAVEL WELL COMPACTED. ADJUST TO ALLOW PROPER BASE ELEVATION DIMENSION SCHEDULE LUMINAIRE TYPE DESIGNATION UNDISTURBED EARTH A B C D PER MANUFACTURER HOT DIPPED GALVANIZED RIGID STEEL CONDUIT WITH THREADED COUPLING. SIZE AS SHOWN ON PLANS TIE REBARS TOGETHER PROVIDE VERTICAL 4-#4 REBARS AND #3 HORIZONTAL REBARS 6" ON CENTERS BA 1" X 45° CHAMFER ALL AROUND COORDINATE LUMINAIRE PLATE SIZE. PROVIDE LARGER BASE IF REQUIRED WEEP SLOT REBARS C 3/4" PVC GROUND CONDUCTOR SLEEVE GROUNDING BUSHING FINISH GRADE ANCHOR BOLT CIRCLE, ORIENTATION AND PROJECTION INSTALLED ACCORDING TO MANUFACTURER'S TEMPLATE COMPACT BACKFILL 3/4" X 10'-0" GROUND ROD COMPACT BACKFILL 18" COMPACT BACKFILL #2 BARE COPPER GROUND WIRE NO SCALE ROUND BASE FOUNDATION DETAIL - SITE LUMINAIRES 51"30" 3"18" 45"30" 3"16" HA HB HOISTWAY BUILDING TA JH LDU TOP OF HOISTWAY SAFETY COMPONENTS TAS JH1 VFD FUSE BOX TSU ABBREVIATION LIST: JH = MAIN ELEVATOR SERVICE DISCONNECT SWITCH WITH SHUNT TRIP PROVIDED BY ELECTRICAL CONTRACTOR. JH1 = HOISTWAY AUXILIARY DISCONNECT SWITCH PROVIDED BY ELEVATOR CONTRACTOR. JHS = INSPECTION AND TEST PANEL SWITCH PROVIDED BY ELEVATOR CONTRACTOR. LDU = INSPECTION AND TEST PANEL PROVIDED BY ELEVATOR CONTRACTOR. TA = 3-PHASE AUTOTRANSFORMER (208V:480V) PROVIDED BY ELEVATOR CONTRACTOR. TSU = MOTOR CONTROLLER PROVIDED BY ELEVATOR CONTRACTOR. TAS = TEST AND INSPECTION PANEL AUTOTRANSFORMER PROVIDED BY ELEVATOR CONTRACTOR. VFD = VARIABLE FREQUENCY DRIVE PROVIDED BY ELEVATOR CONTRACTOR. PDB = POWER DISTRIBUTION BLOCK PROVIDED BY ELEVATOR CONTRACTOR. M = MOTOR PROVIDED BY ELEVATOR CONTRACTOR. FUSE BOX PROVIDED BY ELEVATOR CONTRACTOR. M TO ELECTRICAL PANEL 3 2 2 27 7 7 7 JH JH1 7TO TRANSFORMER TA ELEVATOR FEEDER MAIN SHUNT TRIP CAR FAN CAR LIGHTS SUMP PUMP RECEPT ELEV1 H1A1; 3,5,7 H1A1, 45 H1A1, 43 H1A1 ELEVATOR FEEDER SOURCE SCHEDULE 70A 3P TA JH WALL MOUNTED SMOKE/CO DETECTOR 10" 2 2