HomeMy WebLinkAbout10-E2-43AUP
UP
DN
OPEN
TO
ABOVE
E2
PANEL
T43B3
PANEL
T43B2
PANEL
T43B1
PANEL
T43B4
FACP
13,15
E1
REFER TO TYPICAL
APARTMENT 43.3
REFER TO TYPICAL
APARTMENT 43.4
REFER TO TYPICAL
APARTMENT 43.1
REFER TO TYPICAL
APARTMENT 43.2
TYPE D2
TYPE D2
TYPE D2
TYPE J
D
3
3
11
15
15
2
2
2
2
2
2
2
2
2
2
2
2
4
4
4
2
2
2
2
2
2
TYPICAL
APARTMENT 43.3
TYPICAL
APARTMENT 43.4
TYPICAL
APARTMENT 43.1
TYPICAL
APARTMENT 43.2
UP
UP
OPEN TO
BELOW
DOWN
DOWN
PANEL
T43C2
PANEL
T43C1
RANGE
DISPOSAL
DISHWASHER
RANGE
DISPOSAL
DISHWASHER
RANGE
RANGE DISHWASHER
DISPOSAL
DISHWASHER
DISPOSAL
PANEL
T43C3
PANEL
T43C4
A A
A A
A C A A
C
C A AA
c
A A
A A
A A
A A
C
CA
A
A
AA
A C
A
C
WASHER/DRYER
WASHER/DRYER
WASHER/DRYER
WASHER/DRYER
2
2
2
1
1 1
1
D
A
E1
E1
10
3
10
3
10
3
3
3
1
1
9
9
77
7
7
55
5 5 5
5
5
5
1
3
9
9
11
11
11
11
9
9
3
1
5
5
5
5
5
55
5
5
5 5
5
5
5
5
5
1
3
9
9
11
11
E1
E1
TYPE J
TYPE D2
TYPE D2
TYPE D2
2
2
2
2
2
2
2
2
2
2
2
2
2
4
4
4
2
2
2
2
2
2
2
2
10
3
7
2
1/4"=1'0"
BUILDING 4.3 - LEVEL C2 1/4"=1'0"
BUILDING 4.3 - LEVEL B1
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
COLLEGETOWN
TERRACE APARTMENTS
ITHACA, NY
NOVARR MACKESEY
DEVELOPMENTPROFESSIONAL LICENSE
NUMBER:
NEW YORK STATE SEAL:
a r c h i t e c t s
ikon.5 PROJECT NO.:P58.00
VERSIONS
NO. DATE DESCRIPTION
CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL
ENGINEER:
LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:
12923
NORTH
PROJECTJULY 1, 2011
1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS
KEY PLAN
2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS
ADDENDUM - 1
GENERAL NOTES:
A. CIRCUIT EXIT SIGNS TOGETHER WITH #10 AWG CONDUCTORS
FROM A 20A-1P CIRCUIT BREAKER IN PANEL H43. PROVIDE
CIRCUIT BREAKER HANDLE LOCK.
B. CIRCUIT DESIGNATION ON THIS PLAN REFER TO PANEL H43,
UNLESS NOTED OTHERWISE.
C. CIRCUIT EXTERIOR LIGHTING FIXTURES THROUGH TIME SWITCH
AND ROOF MOUNTED PHOTOCELL FOR PHOTOCELL 'ON' AND TIME
SWITCH 'OFF'. COORDINATE TIME SWITCH SCHEDULE WITH
OWNER.
BUILDING 4.3 FLOOR PLAN - LEVEL B, LEVEL C
KSO
E2.43A
1
KEYED NOTES:
REFER TO FLOOR PLANS FOR EACH APARTMENT PTAC
DESIGNATION.
PROVIDE CONNECTION TO ELECTRIC SPACE HEATER. CIRCUIT
THROUGH LINE VOLTAGE THERMOSTAT. INSTALL THERMOSTAT
FURNISHED BY MECHANICAL CONTRACTOR. REFER TO
MECHANICAL PLANS FOR THERMOSTAT LOCATION.
PROVIDE CONNECTION TO KITCHEN EXHAUST HOOD.
THE CORRIDOR IS CONSIDERED PART OF THE STAIRWAY
ENCLOSURE. ONLY DEVICES AND ASSOCIATED CONDUIT AND
CABLING SERVING THE STAIRWAY ENCLOSURE ARE PERMITTED
TO BE IN THE STAIRWAY. NON-STAIRWAY CONDUITS AND CABLING
SHALL CROSS THE STAIRWAY CORRIDOR IN RATED ENCLOSURES
INDICATED ON THE ARCHITECTURAL DOCUMENTS.
2
3
4
2
2