Loading...
HomeMy WebLinkAbout10-E2-42AUP UP DN OPEN TO ABOVE PANEL T42B3 PANEL T42B2 PANEL T42B1 PANEL T42B4 FACP 15,17 E1 E2 REFER TO TYPICAL APARTMENT 42.1 REFER TO TYPICAL APARTMENT 42.4 REFER TO TYPICAL APARTMENT 42.3 REFER TO TYPICAL APARTMENT 42.2 TYPE D2 TYPE D2 TYPE D2 TYPE J GFCI WP 1 D 15 15 2 2 2 2 2 2 2 2 2 2 4 4 4 2 2 2 2 2 2 2 2 TYPICAL APARTMENT 42.1 TYPICAL APARTMENT 42.4 TYPICAL APARTMENT 42.3 TYPICAL APARTMENT 42.2 UP UP OPEN TO BELOW DOWN DOWN PANEL T42C3 PANEL T42C2 PANEL T42C1 PANEL T42C4 RANGE DISPOSAL DISHWASHER RANGE DISPOSAL DISHWASHER RANGE RANGE DISHWASHER DISPOSAL DISHWASHER DISPOSAL TYPE J TYPE D2 TYPE D2 TYPE D2 A A A A A C A A C C A AA c A A A A A A A A C CA A A AA A C A C A WASHER/DRYER WASHER/DRYER WASHER/DRYER WASHER/DRYER 2 1 1 1 1 2 2 D 10 3 10 3 10 3 10 3 11 11 1 1 9 9 77 7 7 55 5 5 5 5 5 5 1 3 9 9 11 11 11 11 9 9 3 1 5 5 5 5 5 55 5 5 5 5 5 5 5 5 5 1 3 9 9 11 11 15 15 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 2 2 2 2 2 2 2 2 2 7 2 1/4"=1'0" BUILDING 4.2 - LEVEL C2 1/4"=1'0" BUILDING 4.2 - LEVEL B1 DRAWING NO.: DRAWN BY: DATE: SHEET TITLE: PROJECT TITLE: COLLEGETOWN TERRACE APARTMENTS ITHACA, NY NOVARR MACKESEY DEVELOPMENTPROFESSIONAL LICENSE NUMBER: NEW YORK STATE SEAL: a r c h i t e c t s ikon.5 PROJECT NO.:P58.00 VERSIONS NO. DATE DESCRIPTION CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL ENGINEER: LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER: 12923 NORTH PROJECTJULY 1, 2011 1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS KEY PLAN 2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS ADDENDUM - 1 GENERAL NOTES: A. CIRCUIT EXIT SIGNS TOGETHER WITH #10 AWG CONDUCTORS FROM A 20A-1P CIRCUIT BREAKER IN PANEL H42. PROVIDE CIRCUIT BREAKER HANDLE LOCK. B. CIRCUIT DESIGNATION ON THIS PLAN REFER TO PANEL H42, UNLESS NOTED OTHERWISE. C. CIRCUIT EXTERIOR LIGHTING FIXTURES THROUGH TIME SWITCH AND ROOF MOUNTED PHOTOCELL FOR PHOTOCELL 'ON' AND TIME SWITCH 'OFF'. COORDINATE TIME SWITCH SCHEDULE WITH OWNER. BUILDING 4.2 FLOOR PLAN - LEVEL B, LEVEL C KSO E2.42A 1 KEYED NOTES: REFER TO FLOOR PLANS FOR EACH APARTMENT PTAC DESIGNATION. PROVIDE CONNECTION TO ELECTRIC SPACE HEATER. CIRCUIT THROUGH LINE VOLTAGE THERMOSTAT. INSTALL THERMOSTAT FURNISHED BY MECHANICAL CONTRACTOR. REFER TO MECHANICAL PLANS FOR THERMOSTAT LOCATION. PROVIDE CONNECTION TO KITCHEN EXHAUST HOOD. THE CORRIDOR IS CONSIDERED PART OF THE STAIRWAY ENCLOSURE. ONLY DEVICES AND ASSOCIATED CONDUIT AND CABLING SERVING THE STAIRWAY ENCLOSURE ARE PERMITTED TO BE IN THE STAIRWAY. NON-STAIRWAY CONDUITS AND CABLING SHALL CROSS THE STAIRWAY CORRIDOR IN RATED ENCLOSURES INDICATED ON THE ARCHITECTURAL DOCUMENTS. 2 3 4 2 2