HomeMy WebLinkAbout10-E2-41ADN
UP
UP
OPEN
TO
ABOVE
PANEL
T41B3
PANEL
T41B2
PANEL
T41B1
PANEL
T41B4
FACP
7,9
E1
E2
REFER TO TYPICAL
APARTMENT 41.4
REFER TO TYPICAL
APARTMENT 41.1
REFER TO TYPICAL
APARTMENT 41.2
REFER TO TYPICAL
APARTMENT 41.3
TYPE D2
TYPE D2
TYPE D2
TYPE J
GFCI
WP
1
D
5
3
3
2
2
2
2
2
2 2
2
2
2
2
2
4
4
4
2
2
2
TYPICAL
APARTMENT 41.4
TYPICAL
APARTMENT 41.1
TYPICAL
APARTMENT 41.2
TYPICAL
APARTMENT 41.3
UP
UP
OPEN TO
BELOW
DOWN
DOWN
PANEL
T41C3
PANEL
T41C2
PANEL
T41C1
PANEL
T41C4
RANGE
DISPOSAL
DISHWASHER
RANGE
DISPOSAL
DISHWASHER
RANGE
DISPOSAL
DISHWASHER
RANGE
DISPOSAL
DISHWASHER
TYPE J
TYPE D2
TYPE D2
TYPE D2
E1
A A
AA
AAC
C
A
A A
C
C
A
A
A
A A
AA
CA A
A
C
A A C A
C
AA
A A
WASHER/DRYER
WASHER/DRYER
WASHER/DRYER
WASHER/DRYER
2
2
2
1
1
1 1
D
10
3
10
3
10
3
10
3
3
3
3
5
5
5
5
5
5
5
5
5
5
5 5 5
5
5
5
5
5
5
5 5
55
5
1
1
9
9
7
7
7
7
1
3
9
9
11
11
1
11
11
9
9
1
3
9
9
11
11
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
E1
4
4
4
2
2
2
2
2
2
2
2
2
2
7 2
1/4"=1'0"
BUILDING 4.1 - LEVEL C2 1/4"=1'0"
BUILDING 4.1 - LEVEL B1
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
COLLEGETOWN
TERRACE APARTMENTS
ITHACA, NY
NOVARR MACKESEY
DEVELOPMENTPROFESSIONAL LICENSE
NUMBER:
NEW YORK STATE SEAL:
a r c h i t e c t s
ikon.5 PROJECT NO.:P58.00
VERSIONS
NO. DATE DESCRIPTION
CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL
ENGINEER:
LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:
12923
NORTH
PROJECTJULY 1, 2011
1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS
KEY PLAN
2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS
ADDENDUM - 1
GENERAL NOTES:
A. CIRCUIT EXIT SIGNS TOGETHER WITH #10 AWG CONDUCTORS
FROM A 20A-1P CIRCUIT BREAKER IN PANEL H41. PROVIDE
CIRCUIT BREAKER HANDLE LOCK.
B. CIRCUIT DESIGNATION ON THIS PLAN REFER TO PANEL H41,
UNLESS NOTED OTHERWISE.
C. CIRCUIT EXTERIOR LIGHTING FIXTURES THROUGH TIME
SWITCH AND ROOF MOUNTED PHOTOCELL FOR PHOTOCELL
'ON' AND TIME SWITCH 'OFF'. COORDINATE TIME SWITCH
SCHEDULE WITH OWNER.
BUILDING 4.1 FLOOR PLAN - LEVEL B, LEVEL C
KSO
E2.41A
1
KEYED NOTES:
REFER TO FLOOR PLANS FOR EACH APARTMENT PTAC
DESIGNATION.
PROVIDE CONNECTION TO ELECTRIC SPACE HEATER. CIRCUIT
THROUGH LINE VOLTAGE THERMOSTAT. INSTALL
THERMOSTAT FURNISHED BY MECHANICAL CONTRACTOR.
REFER TO MECHANICAL PLANS FOR THERMOSTAT LOCATION.
PROVIDE CONNECTION TO KITCHEN EXHAUST HOOD.
THE CORRIDOR IS CONSIDERED PART OF THE STAIRWAY
ENCLOSURE. ONLY DEVICES AND ASSOCIATED CONDUIT AND
CABLING SERVING THE STAIRWAY ENCLOSURE ARE
PERMITTED TO BE IN THE STAIRWAY. NON-STAIRWAY
CONDUITS AND CABLING SHALL CROSS THE STAIRWAY
CORRIDOR IN RATED ENCLOSURES INDICATED ON THE
ARCHITECTURAL DOCUMENTS.
2
3
2
4
2