Loading...
HomeMy WebLinkAbout10-E2-41ADN UP UP OPEN TO ABOVE PANEL T41B3 PANEL T41B2 PANEL T41B1 PANEL T41B4 FACP 7,9 E1 E2 REFER TO TYPICAL APARTMENT 41.4 REFER TO TYPICAL APARTMENT 41.1 REFER TO TYPICAL APARTMENT 41.2 REFER TO TYPICAL APARTMENT 41.3 TYPE D2 TYPE D2 TYPE D2 TYPE J GFCI WP 1 D 5 3 3 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 2 2 2 TYPICAL APARTMENT 41.4 TYPICAL APARTMENT 41.1 TYPICAL APARTMENT 41.2 TYPICAL APARTMENT 41.3 UP UP OPEN TO BELOW DOWN DOWN PANEL T41C3 PANEL T41C2 PANEL T41C1 PANEL T41C4 RANGE DISPOSAL DISHWASHER RANGE DISPOSAL DISHWASHER RANGE DISPOSAL DISHWASHER RANGE DISPOSAL DISHWASHER TYPE J TYPE D2 TYPE D2 TYPE D2 E1 A A AA AAC C A A A C C A A A A A AA CA A A C A A C A C AA A A WASHER/DRYER WASHER/DRYER WASHER/DRYER WASHER/DRYER 2 2 2 1 1 1 1 D 10 3 10 3 10 3 10 3 3 3 3 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 55 5 1 1 9 9 7 7 7 7 1 3 9 9 11 11 1 11 11 9 9 1 3 9 9 11 11 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 E1 4 4 4 2 2 2 2 2 2 2 2 2 2 7 2 1/4"=1'0" BUILDING 4.1 - LEVEL C2 1/4"=1'0" BUILDING 4.1 - LEVEL B1 DRAWING NO.: DRAWN BY: DATE: SHEET TITLE: PROJECT TITLE: COLLEGETOWN TERRACE APARTMENTS ITHACA, NY NOVARR MACKESEY DEVELOPMENTPROFESSIONAL LICENSE NUMBER: NEW YORK STATE SEAL: a r c h i t e c t s ikon.5 PROJECT NO.:P58.00 VERSIONS NO. DATE DESCRIPTION CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL ENGINEER: LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER: 12923 NORTH PROJECTJULY 1, 2011 1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS KEY PLAN 2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS ADDENDUM - 1 GENERAL NOTES: A. CIRCUIT EXIT SIGNS TOGETHER WITH #10 AWG CONDUCTORS FROM A 20A-1P CIRCUIT BREAKER IN PANEL H41. PROVIDE CIRCUIT BREAKER HANDLE LOCK. B. CIRCUIT DESIGNATION ON THIS PLAN REFER TO PANEL H41, UNLESS NOTED OTHERWISE. C. CIRCUIT EXTERIOR LIGHTING FIXTURES THROUGH TIME SWITCH AND ROOF MOUNTED PHOTOCELL FOR PHOTOCELL 'ON' AND TIME SWITCH 'OFF'. COORDINATE TIME SWITCH SCHEDULE WITH OWNER. BUILDING 4.1 FLOOR PLAN - LEVEL B, LEVEL C KSO E2.41A 1 KEYED NOTES: REFER TO FLOOR PLANS FOR EACH APARTMENT PTAC DESIGNATION. PROVIDE CONNECTION TO ELECTRIC SPACE HEATER. CIRCUIT THROUGH LINE VOLTAGE THERMOSTAT. INSTALL THERMOSTAT FURNISHED BY MECHANICAL CONTRACTOR. REFER TO MECHANICAL PLANS FOR THERMOSTAT LOCATION. PROVIDE CONNECTION TO KITCHEN EXHAUST HOOD. THE CORRIDOR IS CONSIDERED PART OF THE STAIRWAY ENCLOSURE. ONLY DEVICES AND ASSOCIATED CONDUIT AND CABLING SERVING THE STAIRWAY ENCLOSURE ARE PERMITTED TO BE IN THE STAIRWAY. NON-STAIRWAY CONDUITS AND CABLING SHALL CROSS THE STAIRWAY CORRIDOR IN RATED ENCLOSURES INDICATED ON THE ARCHITECTURAL DOCUMENTS. 2 3 2 4 2