Loading...
HomeMy WebLinkAbout10-E2-40UP UPUP PANEL H43 X1 METER CENTER MC42 METER CENTER MC41 PANEL H42 PANEL H411 X1 GFCI GFCI 1 TYPICAL BOLLARD TYPICAL BOLLARD DATA RACK MDF-4.3 4'W X 8'H VERIZON BACKBOARD 4'W X 8'H TIME WARNER BACKBOARD X1 DATA RACK MDF-4.1 4'W X 8'H VERIZON BACKBOARD 4'W X 8'H TIME WARNER BACKBOARD GFCI WP 1 GFCI WP 1 GFCI WP 1 GFCI WP 9 GFCI WP 1 GFCI WP 9 GFCI WP 1 GFCI WP 1 TYPICAL BOLLARD DATA RACK MDF-4.2 4'W X 8'H TELEPHONE BACKBOARD 4' W X 8'H TIME WARNER BACKBOARD X1X1 GFCI 1 GFCI 1 TYPICAL TYPICALTYPICAL TYPICALTYPICAL TYPICAL METER CENTER MC43 GFCI 1 GFCI 11 GFCI GFCI 1 PANEL H412 PANEL H421 PANEL H422 PANEL H431 PANEL H432 GFCI 1 26 H411 26 H42126 H431 2 2 2 33 11 35 11 2 35 11 2 33 11 33 11 33 11 33 11 33 11 33 11 33 11 33 11 33 11 33 11 2 2 2 2 2 2 2 2 2 35 11 2 18 12 12 18 12 20 12 20 2 2 2 2 2 20 12 2 20 12 2 2 20 12 2 18 12 20 12 2 18 12 20 12 18 12 2 2 20 12 33 13 13 33 13 35 13 35 2 2 2 2 2 35 13 2 35 13 2 2 35 13 2 33 13 35 13 2 33 13 35 13 33 13 2 35 13 33 13 1 GFCI PANEL H421 PANEL H422 18 12 TS14 2 TS14 2 TS14 2 TS14 2 TS14 2 TS14 2 2 1/8"=1'0" BUILDING 4.0 - LEVEL A1 DRAWING NO.: DRAWN BY: DATE: SHEET TITLE: PROJECT TITLE: COLLEGETOWN TERRACE APARTMENTS ITHACA, NY NOVARR MACKESEY DEVELOPMENTPROFESSIONAL LICENSE NUMBER: NEW YORK STATE SEAL: a r c h i t e c t s ikon.5 PROJECT NO.:P58.00 VERSIONS NO. DATE DESCRIPTION CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL ENGINEER: LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER: 12923 NORTH PROJECTJULY 1, 2011 1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS KEY PLAN 2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS ADDENDUM - 1 1 KEYED NOTES: REFER TO ARCHITECTURAL DOCUMENTS FOR RECEPTACLE ELEVATIONS. APPROXIMATE LOCATION OF TENANT PANELBOARD FEEDERS ABOVE (LEVELS B, C, AND D). CORE DRILL HOLLOW CORE PRECAST FLOOR SLABS AND ROUTE TENANT PANELBOARD FEEDERS WITHIN STUD WALLS TO ASSOCIATED PANELBOARDS. MAINTAIN PROPER SPACING BETWEEN FEEDER CABLES PER NEC. NOT USED. TIME WARNER CABLE EQUIPMENT CABINET(S) PROVIDED BY TIME WARNER. PROVIDE POWER CONNECTION TO MECHANICAL TEMPERATURE CONTROL PANEL USING 2#12, #12G, 1/2"C FROM 20A-1P CIRCUIT BREAKER. PROVIDE CONCRETE PAD UNDER METER CENTER. PROVIDE PANELBOARD FEEDERS IN CONDUIT FROM METER CENTER TO ABOVE CEILING. PROVIDE 2#10, #10G, 1/2"C FROM 30A-1P CIRCUIT BREAKER IN PANEL H411 TO FIRE PROTECTION HEAT TRACE CONTROL PANEL. PROVIDE SUPERVISORY FIRE ALARM CONNECTION TO CONTROL PANEL. PROVIDE 2#10, #10G, 1/2"C FROM 30A-1P CIRCUIT BREAKER IN PANEL H421 TO FIRE PROTECTION HEAT TRACE CONTROL PANEL. PROVIDE SUPERVISORY FIRE ALARM CONNECTION TO CONTROL PANEL. PROVIDE 2#10, #10G, 1/2"C FROM 30A-1P CIRCUIT BREAKER IN PANEL H431 TO FIRE PROTECTION HEAT TRACE CONTROL PANEL. PROVIDE SUPERVISORY FIRE ALARM CONNECTION TO CONTROL PANEL. PROVIDE 2 #10,#10G,1/2C FROM 20A-1P GFCI CIRCUIT BREAKER IN PANEL H411 TO JUNCTION BOX FOR HEAT TAPE. MOUNT JUNCTION BOX ABOVE ACCESSIBLE CEILING. PROVIDE DISCONNECT SWITCH AT JUNCTION BOX. VERIFY EXACT LOCATION WITH PLUMBING CONTRACT. PROVIDE 2 #10,#10G,1/2C FROM 20A-1P GFCI CIRCUIT BREAKER IN PANEL H421 TO JUNCTION BOX FOR HEAT TAPE. MOUNT JUNCTION BOX ABOVE ACCESSIBLE CEILING. PROVIDE DISCONNECT SWITCH AT JUNCTION BOX. VERIFY EXACT LOCATION WITH PLUMBING CONTRACT. PROVIDE 2 #10,#10G,1/2C FROM 20A-1P GFCI CIRCUIT BREAKER IN PANEL H431 TO JUNCTION BOX FOR HEAT TAPE. MOUNT JUNCTION BOX ABOVE ACCESSIBLE CEILING. PROVIDE DISCONNECT SWITCH AT JUNCTION BOX. VERIFY EXACT LOCATION WITH PLUMBING CONTRACT. PROVIDE FIRE ALARM SYSTEM SUPERVISORY CONNECTION TO TEMPERATURE SENSOR LOCATED IN GARAGE LEVEL CEILING SPACE. SENSOR PROVIDED BY MECHANICAL CONTRACTOR. COORDINATE LOCATION WITH MECHANICAL CONTRACTOR. GENERAL NOTES: A. FEEDER ROUTING IS DIAGRAMMATIC. COORDINATE ROUTING WITH OTHER TRADES AND ACTUAL FIELD CONDITIONS. B. CIRCUIT EXIT SIGNS TOGETHER IN EACH BUILDING WITH #10 AWG CONDUCTORS FROM A 20A-1P CIRCUIT BREAKER IN PANEL THE BUILDING HOUSE PANEL (PANEL H412 FOR BUILDING 4.1, PANEL H422 FOR BUILDING 4.2, PANEL H432 FOR BUILDING 4.3). PROVIDE CIRCUIT BREAKER HANDLE LOCKS. C. UNLESS NOTED OTHERWISE, CIRCUIT DESIGNATION ON THIS PLAN REFER TO THE BUILDING HOUSE PANEL (PANEL H412 FOR BUILDING 4.1, PANEL H422 FOR BUILDING 4.2, PANEL H422 FOR BUILDING 4.3). D. IN GENERAL, STRUCTURAL BEAM SIZES IN THE GARAGE LEVEL PROHIBIT PASSING CONDUITS, CONDUCTORS, PIPING, ETC., BETWEEN THE BOTTOM OF BEAM AND CEILING/CEILING INSULATION SYSTEM. DO NOT RUN CONDUITS, CONDUCTORS, PIPING, ETC. WITHIN THE INSULATION SYSTEM. THERE ARE SPACES WHERE BEAMS HAVE OPENINGS TO PASS UTILITIES THROUGH THE BEAM; REFER TO STRUCTURAL DOCUMENTS. COORDINATE ALL UTILITY PENETRATIONS THROUGH BEAMS WITH OTHER TRADES PRIOR TO COMMENCEMENT OF ANY WORK. E. BOLLARDS LOCATED IN GARAGE LEVEL ARE SHOWN FOR REFERENCE ONLY AND ARE PROVIDED BY THE GENERAL CONTRACTOR. F. CIRCUIT GARAGE LIGHTING AN EXTERIOR LIGHTING THROUGH MULTIPOLE LIGHTING CONTACTORS AND TIME SWITCH. PROVIDE SEPARATE SCHEDULES FOR GARAGE LIGHTING AND EXTERIOR LIGHTING. PROVIDE PHOTOCELL CONNECTION TO ROOF MOUNTED PHOTOCELL. BUILDING 4.0 FLOOR PLAN - LEVEL A KSO E2.40 2 3 4 5 6 7 8 9 10 2 11 2 12 13 14