HomeMy WebLinkAbout10-E2-23ATYPICAL
APARTMENT 23.2
TYPICAL
APARTMENT 23.3
TYPICAL
APARTMENT 23.1
TYPICAL
APARTMENT 23.4
OPEN TO
BELOW
UPDN
DN UP
PANEL
T23D4
PANEL
T23D2
PANEL
T23D3
PANEL
T23D1
E1
E1
E1
RANGE
DISPOSAL
DISHWASHER
RANGE
DISPOSAL
DISHWASHER
DISPOSAL
DISHWASHER
RANGE
DISHWASHER
DISPOSAL
1
1
RANGE
TYPE A
TYPE A
TYPE D1TYPE D1
A A
A
A
A
CA
A
C
A
A
C
C
A
AA
AA
AAC
C
A
A
A
C
A
A
WASHER/
DRYER 17:19WASHER/
DRYER 17:19
WASHER/
DRYER 17:19
WASHER/
DRYER 17:19
2
22
2
7
7
1
9
9
7
7
7
1
1
9
9
3
1
5
5
55
5 5
5
5
11
11
9
9
11
11
9
9
5
5
5 5
5
5 5
3
1
7
6
5
3
3
3
3
5
7
7
7 7
2
2
2
2
2
2
2
22
2
88
2
2
2
8
8
2
2
2
9
9
9
2
2
2
DN UP
UP
OPEN TO
ABOVE
PANEL
T23C4
PANEL
T23C2
PANEL
T23C3
PANEL
T23C1
RA
E1
REFER TO TYPICAL
APARTMENT 23.2
REFER TO TYPICAL
APARTMENT 23.4
REFER TO TYPICAL
APARTMENT 23.3
REFER TO TYPICAL
APARTMENT 23.1
TYPE A
TYPE A
TYPE D1TYPE D1
GFCI
WP
1
MS11
22
2
2
2
2
9
9
9
1/8"=1'0"
BUILDING 2.3 - LEVEL D2 1/4"=1'0"
BUILDING 2.3 - LEVEL C1
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
COLLEGETOWN
TERRACE APARTMENTS
ITHACA, NY
NOVARR MACKESEY
DEVELOPMENTPROFESSIONAL LICENSE
NUMBER:
NEW YORK STATE SEAL:
a r c h i t e c t s
ikon.5 PROJECT NO.:P58.00
VERSIONS
NO. DATE DESCRIPTION
CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL
ENGINEER:
LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:
12923
NORTH
PROJECTJULY 1, 2011
1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS
KEY PLAN
2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS
ADDENDUM - 1
1
KEYED NOTES:
PROVIDE STANDARD 15CD HORN STROBE. IF REQUIRED IN THE FUTURE, THE OWNER SHALL
REPLACE THIS DEVICE WITH A 177CD DEVICE TO MEET ADA OCCUPANCY REQUIREMENTS.
REFER TO FLOOR PLANS FOR EACH APARTMENT PTAC DESIGNATION.
PROVIDE CONNECTION TO KITCHEN EXHAUST HOOD.
TIME WARNER EQUIPMENT CABINETS PROVIDED BY TIME WARNER. PROVIDE PLYWOOD
BACKBOARD COVERING THE SOUTH WALL.
CLOSET RESERVED FOR FUTURE VERIZON SERVICE EQUIPMENT. PROVIDE PLYWOOD BACKBOARD
COVERING THE SOUTH WALL.
CORE DRILL FLOOR AND PROVIDE TWO 4" SLEEVES FOR TIME WARNER CABLING.
GENERAL NOTES:
A. CIRCUIT EXIT SIGNS ON LEVELS C, D, AND E TOGETHER WITH #10
AWG CONDUCTORS FROM A 20A-1P CIRCUIT BREAKER IN PANEL
H23. PROVIDE CIRCUIT BREAKER HANDLE LOCK.
B. CIRCUIT DESIGNATION ON THIS PLAN REFER TO PANEL H23,
UNLESS NOTED OTHERWISE.
C. CIRCUIT EXTERIOR LIGHTING FIXTURES THROUGH TIME SWITCH
AND ROOF MOUNTED PHOTOCELL FOR PHOTOCELL 'ON' AND TIME
SWITCH 'OFF'. COORDINATE TIME SWITCH SCHEDULE WITH
OWNER.
BUILDING 2.3 FLOOR PLAN - LEVEL C, LEVEL D
KSO
E2.23A
2
3
4
5
2
KEYED NOTES:
CORE DRILL FLOOR AND PROVIDE TWO 4" SLEEVES FOR
FUTURE VERIZON SERVICES.
PROVIDE DUPLEX RECEPTACLE TO SERVE CONDENSATE
PUMP ON C-LEVEL. RECEPTACLE SHALL BE ACCESSIBLE.
COORDINATE LOCATION WITH PLUMPING CONTRACTOR. D
AND E LEVELS DO NOT REQUIRE CONDENSATE PUMP
RECEPTACLES.
THE CORRIDOR IS CONSIDERED PART OF THE STAIRWAY
ENCLOSURE. ONLY DEVICES AND ASSOCIATED CONDUIT AND
CABLING SERVING THE STAIRWAY ENCLOSURE ARE
PERMITTED TO BE IN THE STAIRWAY. NON-STAIRWAY
CONDUITS AND CABLING SHALL CROSS THE STAIRWAY
CORRIDOR IN RATED ENCLOSURES INDICATED ON THE
ARCHITECTURAL DOCUMENTS.
7
8
2
9
6