HomeMy WebLinkAbout10-E2-21AUP UPDN OPEN TO ABOVE PANEL T21C1 PANEL T21C2 PANEL T21C3 E1 REFER TO TYPICAL APARTMENT 21.1 REFER TO TYPICAL APARTMENT 21.2REFER TO TYPICAL APARTMENT 21.3 REFER TO TYPICAL APARTMENT 21.4 TYPE D TYPE B TYPE B PANEL T21C4 TYPE B1 GFCI WP 5 E1 7 7 MS K FACP 2,4 2 2 5 5 5 2 2 2 2 2 TYPICAL APARTMENT 21.2 TYPICAL APARTMENT 21.3 TYPICAL APARTMENT 21.1 TYPICAL APARTMENT 21.4 OPEN TO BELOW UP UPDN DN PANEL T21D1 PANEL T21D2 PANEL T21D3 PANEL T21D4 E1 E1 RANGE DISPOSAL DISWASHER RANGE DISPOSAL DISWASHER RANGE DISPOSAL DISWASHER RANGE DISPOSAL DISWASHER TYPE B TYPE B TYPE D TYPE B1 A A A A AACA C AA A A C A C A A A A A C C A A A CA A C WASHER/ DRYER 17;19 WASHER/ DRYER 17;19 WASHER/ DRYER 17;19 WASHER/ DRYER 17;19 2 2 2 2 1 1 1 7 7 3 3 3 3 1 9 9 7 77 7 7 7 7 7 7 1 9 9 9 9 1 7 77 5 5 5 5 5 9 9 5 5 7 7 K 16,18 16,18 16,18 16,18 4 4 4 4 6 6 6 1/4"=1'0" BUILDING 2.1 - LEVEL D2 1/4"=1'0" BUILDING 2.1 - LEVEL C1 DRAWING NO.: DRAWN BY: DATE: SHEET TITLE: PROJECT TITLE: COLLEGETOWN TERRACE APARTMENTS ITHACA, NY NOVARR MACKESEY DEVELOPMENTPROFESSIONAL LICENSE NUMBER: NEW YORK STATE SEAL: a r c h i t e c t s ikon.5 PROJECT NO.:P58.00 VERSIONS NO. DATE DESCRIPTION CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL ENGINEER: LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER: 12923 NORTH PROJECTJULY 1, 2011 1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS KEY PLAN 2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS ADDENDUM - 1 GENERAL NOTES: A. CIRCUIT EXIT SIGNS ON LEVELS C, D, AND E TOGETHER WITH #10 AWG CONDUCTORS FROM A 20A-1P CIRCUIT BREAKER IN PANEL H21. PROVIDE CIRCUIT BREAKER HANDLE LOCK. B. CIRCUIT DESIGNATION ON THIS PLAN REFER TO PANEL H21, UNLESS NOTED OTHERWISE. C. CIRCUIT EXTERIOR LIGHTING FIXTURES THROUGH TIME SWITCH AND ROOF MOUNTED PHOTOCELL FOR PHOTOCELL 'ON' AND TIME SWITCH 'OFF'. COORDINATE TIME SWITCH SCHEDULE WITH OWNER. BUILDING 2.1 FLOOR PLAN - LEVEL C, LEVEL D KSO E2.21A 1 KEYED NOTES: REFER TO FLOOR PLANS FOR EACH APARTMENT PTAC DESIGNATION. PROVIDE CONNECTION TO ELECTRIC WALL HEATER. CIRCUIT THROUGH LINE VOLTAGE THERMOSTAT. INSTALL THERMOSTAT FURNISHED BY MECHANICAL CONTRACTOR. REFER TO MECHANICAL PLANS FOR THERMOSTAT LOCATION. PROVIDE CONNECTION TO KITCHEN EXHAUST HOOD. PROVIDE DUPLEX RECEPTACLE TO SERVE CONDENSATE PUMP ON C-LEVEL. RECEPTACLE SHALL BE ACCESSIBLE. COORDINATE LOCATION WITH PLUMPING CONTRACTOR. D AND E LEVELS DO NOT REQUIRE CONDENSATE PUMP RECEPTACLES. 2 3 4 2 22 2 2 2 2 2 2 2 2 2 5 KEYED NOTES (CONTINUATION): THE CORRIDOR IS CONSIDERED PART OF THE STAIRWAY ENCLOSURE. ONLY DEVICES AND ASSOCIATED CONDUIT AND CABLING SERVING THE STAIRWAY ENCLOSURE ARE PERMITTED TO BE IN THE STAIRWAY. NON-STAIRWAY CONDUITS AND CABLING SHALL CROSS THE STAIRWAY CORRIDOR IN RATED ENCLOSURES INDICATED ON THE ARCHITECTURAL DOCUMENTS. 2 2 2 2 2 2 2 2 2 2