Loading...
HomeMy WebLinkAbout10-E2-20TYPICAL APARTMENT 24.2 L ENT 24.1 B A 65 74321 UPUPUP DN 1.5 1.3 3.7 4.1 6.7 7.11.1 STAIRS STAIRS STAIRS X2 X1 X2 X2 X1 X1 WP WP WPWP METER CENTER MC22 TYPICAL BOLLARD DATA RACK MDF-21 4' X 4' VERIZON BACKBOARD 4' X 4' TIME WARNER BACKBOARD GFCI WP H23, 7 GFCI WP H22,9 1 PANEL H22 TYPICAL BOLLARDPANEL H23 TYPICAL BOLLARD H21,1TYPICAL 1 TYPICAL 1 TYPICAL 6 57 GFCI WP,9 GFCI WP H23, 7 GFCI WP H23, 7 GFCI WP H21, 5 GFCI WP H21, 5 H21, 5 H21, 5 H21 5 4 3 H21 11 WPWPWPWP WPWPWPWP H21,9 H21,3 8 9 EM EM 10 H21 15 PANEL H21 PANEL H21M1TYPICAL BOLLARD 2 2 2 2 11 2 11 11 11 H21,22 11 H22,17 11 H21,22 11 H21,22 11 H21,22 11 11 H21,22 H21,22 H21,22 H21,22 H22,17 11 H22,17 11 H22,17 11 H22,15 11 H22,15 11 H22,15 11 H22,15 11 H23,22 11 H23,20 11 H22,17 H22,17 H22,15 11 H23,20 11 H23,20 11 H23,20 11 H23,20 11 H23,20 11 H23,20 11 H23,2211 H23,22 11 H23,22 11 H23,22 11 H23,22 11 H23,22 11 H23,22 2 2 2 2 2 2 22 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 TS12 2 TS12 2 DRAWING NO.: DRAWN BY: DATE: SHEET TITLE: PROJECT TITLE: COLLEGETOWN TERRACE APARTMENTS ITHACA, NY NOVARR MACKESEY DEVELOPMENTPROFESSIONAL LICENSE NUMBER: NEW YORK STATE SEAL: a r c h i t e c t s ikon.5 PROJECT NO.:P58.00 VERSIONS NO. DATE DESCRIPTION CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL ENGINEER: LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER: 12923 NORTH PROJECTJULY 1, 2011 1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS KEY PLAN 2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS ADDENDUM - 1 1/8"=1'0" BUILDING 2.0 - LEVEL B1 BUILDING 2 FLOOR PLAN - LEVEL B KSO E2.20 1 2 KEYED NOTES: APPROXIMATE LOCATION OF TENANT PANELBOARD FEEDERS ABOVE (LEVELS C, D, AND E). CORE DRILL HOLLOW CORE PRECAST FLOOR SLABS AND ROUTE TENANT PANELBOARD FEEDERS WITHIN STUD WALLS TO ASSOCIATED PANELBOARDS. MAINTAIN PROPER SPACING BETWEEN FEEDER CABLES PER NEC. NOT USED TIME WARNER CABLE EQUIPMENT CABINET(S) PROVIDED BY TIME WARNER. PROVIDE POWER CONNECTION TO MECHANICAL TEMPERATURE CONTROL PANEL USING 2#12, #12G, 1/2"C FROM 20A-1P CIRCUIT BREAKER. PROVIDE MULTIPOLE LIGHTING CONTACTORS AND TIME SWITCHES TO CONTROL SITE AND GARAGE LEVEL LIGHTING FIXTURES. PROVIDE SEPARATE SCHEDULES FOR GARAGE AND SITE LIGHTING. PROVIDE CONCRETE PAD UNDER METER CENTER. PROVIDE PANELBOARD FEEDERS IN CONDUIT FROM METER CENTER TO ABOVE CEILING. CIRCUIT GARAGE LIGHTING THROUGH LIGHT SWITCHES IN MECHANICAL ROOM. INSTALL BUILDING 2.1 ROOF FAN CONTROLLERS FURNISHED BY MECHANICAL CONTRACTOR IN MECHANICAL ROOM. PROVIDE 2#10, #10G, 1/2"C FROM 30A-1P CIRCUIT BREAKER IN PANEL H21 TO FIRE PROTECTION HEAT TRACE CONTROL PANEL. PROVIDE SUPERVISORY FIRE ALARM CONNECTION TO CONTROL PANEL. PROVIDE 2 #10,#10G,1/2C FROM 20A-1P GFCI CIRCUIT BREAKER IN PANEL INDICATED, TO JUNCTION BOX FOR HEAT TAPE. MOUNT JUNCTION BOX ABOVE ACCESSIBLE CEILING. PROVIDE DISCONNECT SWITCH AT JUNCTION BOX. VERIFY EXACT LOCATION WITH PLUMBING CONTRACT. PROVIDE FIRE ALARM SYSTEM SUPERVISORY CONNECTION TO TEMPERATURE SENSOR LOCATED IN GARAGE LEVEL CEILING SPACE. SENSOR PROVIDED BY MECHANICAL CONTRACTOR. COORDINATE LOCATION WITH MECHANICAL CONTRACTOR. GENERAL NOTES: A. FEEDER ROUTING IS DIAGRAMMATIC. COORDINATE ROUTING WITH OTHER TRADES AND ACTUAL FIELD CONDITIONS. B. CIRCUIT EXIT SIGNS TOGETHER WITH #10 AWG CONDUCTORS FROM A 20A-1P CIRCUIT BREAKER IN PANEL H21. PROVIDE CIRCUIT BREAKER HANDLE LOCK. C. CIRCUIT DESIGNATION ON THIS PLAN REFER TO PANEL H21, UNLESS NOTED OTHERWISE. D. IN GENERAL, STRUCTURAL BEAM SIZES IN THE GARAGE LEVEL PROHIBIT PASSING CONDUITS, CONDUCTORS, PIPING, ETC., BETWEEN THE BOTTOM OF BEAM AND CEILING/CEILING INSULATION SYSTEM. DO NOT RUN CONDUITS, CONDUCTORS, PIPING, ETC. WITHIN THE INSULATION SYSTEM. THERE ARE SPACES WHERE BEAMS HAVE OPENINGS TO PASS UTILITES THROUGH THE BEAM; REFER TO STRUCTURAL DOCUMENTS. COORDINATE ALL UTILITY PENETRATIONS THROUGH BEAMS WITH OTHER TRADES PRIOR TO COMMENCEMENT OF ANY WORK. E. BOLLARDS LOCATED IN GARAGE LEVEL ARE SHOWN FOR REFERENCE ONLY AND ARE PROVIDED BY THE GENERAL CONTRACTOR. F. CIRCUIT GARAGE LIGHTING AN EXTERIOR LIGHTING THROUGH MULTIPOLE LIGHTING CONTACTORS AND TIME SWITCH. PROVIDE SEPARATE SCHEDULES FOR GARAGE LIGHTING AND EXTERIOR LIGHTING. PROVIDE PHOTOCELL CONNECTION TO ROOF MOUNTED PHOTOCELL. 3 4 5 6 7 8 9 10 2 112 12