Loading...
HomeMy WebLinkAbout10-E0-01DRAWING NO.: DRAWN BY: DATE: SHEET TITLE: PROJECT TITLE: COLLEGETOWN TERRACE APARTMENTS ITHACA, NY NOVARR MACKESEY DEVELOPMENTPROFESSIONAL LICENSE NUMBER: NEW YORK STATE SEAL: a r c h i t e c t s ikon.5 PROJECT NO.:P58.00 VERSIONS NO. DATE DESCRIPTION CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL ENGINEER: LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER: 12923 JULY 1, 2011 1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS KEY PLAN 2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS ADDENDUM - 1 ELECTRICAL SYMBOL LIST AND STANDARD NOTES KSO E0.01 ELECTRICAL SYMBOL LIST EXISTING EQUIPMENT/WORK. NEW EQUIPMENT/WORK. 3 REFERENCE TO DRAWING NOTE EWC ELECTRIC WATER COOLER AC ABOVE COUNTER AFF ABOVE FINISHED FLOOR GFI GFCI GROUND FAULT CIRCUIT INTERRUPTER TYPE RECEPTACLE WG WIRE GUARD WP WATERPROOF (OR) WEATHERPROOF C CONDUIT BRANCH CIRCUIT TO PANELBOARD, WHEN SHOWN, LETTERING INDICATES PANELBOARD DESIGNATIONS. QUANTITY OF ARROWHEADS INDICATE QUANTITY OF BRANCH CIRCUITS. PROTECT EACH BRANCH CIRCUIT WITH A 20 AMPERE, 1-POLE OVERCURRENT DEVICE UNLESS OTHER SIZE INDICATED. TYPICAL DESIGNATION, (2#12,1#12G-1/2"C,20A-1P.) 3 LLPB 5 ON BRANCH CIRCUITRY WHERE ONLY THE CIRCUIT NUMBER IS SHOWN, CIRCUIT RECEPTACLES WITH THE SAME NUMBER TO THE CIRCUIT INDICATED WITH A HOMERUN TO EACH NUMBERED GROUP. CONNECT TO A 20A-1P CIRCUIT BREAKER, OR AS NOTED FOR SPECIAL PURPOSE RECEPTACLES. 32 B 811 4 ON BRANCH CIRCUITRY WHERE ONLY THE CIRCUIT NUMBER IS SHOWN, CIRCUIT LUMINAIRES WITH THE SAME NUMBER TO THE CIRCUIT INDICATED WITH A HOMERUN TO EACH NUMBERED GROUP. CONNECT TO A 20A-1P CIRCUIT BREAKER, OR AS NOTED. 114 22 DIAGRAM CIRCUIT DESIGNATION. REFER TO SCHEDULE ON DIAGRAM.2 BRANCH CIRCUIT PANELBOARD. REFER TO PANEL BOARD SCHEDULE. J JUNCTION BOX 3 LIGHTING CONTROL SWITCH. LIGHTING WALL SWITCHES, 1 POLE IF NO NOTATION. 3=3 WAY, 4=4 WAY, K=KEY TYPE LOWER CASE LETTER INDICATES CONTROL DESIGNATION. OS OCCUPANCY SENSOR, CEILING MOUNTED. OS OCCUPANCY SENSOR, WALL MOUNTED. DUPLEX RECEPTACLE QUAD RECEPTACLE SPECIAL PURPOSE RECEPTACLE. 3 INDICATION OF GANGED DEVICES LIGHTING FIXTURE LIGHTING FIXTURE, WALL xxEM LIGHTING FIXTURE WITH DESIGNATION ENDING "EM " CONTAINS INTEGRAL FLUORESCENT EMERGENCY POWER UNIT LIGHTING FIXTURE, FLUORESCENT STRIP EMERGENCY LIGHTING FIXTURE, INTEGRAL BATTERY EXIT LIGHT FIXTURE EXIT LIGHT FIXTURE, WALL MOUNTED M F1 EQUIPMENT CONNECTION, WITH DESIGNATION FROM ELECTRIC EQUIPMENT AND CONTROL SCHEDULE F1 LOCATION OF ONE OR MORE EQUIPMENT CONTROL DEVICES AS SCHEDULED ON ELECTRIC EQUIPMENT AND CONTROL SCHEDULE. DESIGNATION REFERS TO EQUIPMENT CONTROLLED DISCONNECT SWITCH, VOLTAGE AND AMPERE RATING TO MATCH EQUIPMENT SERVED. REFER TO ELECTRIC EQUIPMENT AND CONTROL SCHEDULE FOR FUSING REQUIREMENTS. D DOOR BUZZER F FIRE ALARM SYSTEM, MANUAL PULL STATION FIRE ALARM SYSTEM, NOTIFICATION APPLIANCE, HORN STROBE. V=VISUAL ONLY. NUMBER = CANDELLA RATINGV, 75F FIRE ALARM SYSTEM, THERMODETECTOR, COMBINATION FIXED TEMPERATURE/RATE-OF-RISE, FIXED TEMPERATURE RATING 135°F, UNLESS INDICATED OTHERWISE. H FIRE ALARM SYSTEM SMOKE DETECTOR. "DT" INDICATES DUCT MOUNTED TYPE WITH REMOTE TEST STATION. DT S ELECTRICAL SYMBOL LIST F F FIRE ALARM SYSTEM, MAGNETIC DOOR HOLDER, INDIVIDUAL,WALL MOUNTED. SUBSCRIPT "F" INDICATES FLOOR MOUNTED. SH FIRE ALARM SYSTEM, CONNECTION TO SMOKE HATCH FS FIRE ALARM SYSTEM, CONNECTION TO SPRINKLER FLOW SWITCH. NUMBER INDICATES QUANTITY TS1- FIRE ALARM SYSTEM, CONNECTION TO SPRINKLER SYSTEM TAMPER SWITCH. NUMBER INDICATES QUANTITY PIV FIRE ALARM SYSTEM, CONNECTION TO SPRINKLER/ STANDPIPE SYSTEM PIV VALVE TAMPER SWITCH WALL MOUNTED TELEPHONE OUTLET WORKSTATION OUTLET LAYOUT. LETTER INDICATES TYPE, NUMBER INDICATES BRANCH CIRCUIT NUMBER. REFER TO DETAIL.a1 TELEVISION OUTLET W/RECEPTACLE. LETTER INDICATES TYPE, NUMBER INDICATES BRANCH CIRCUIT NUMBER REFER TO DETAIL. 1 aTV FUSED DISCONNECT SWITCH, RATINGS AS INDICATED STANDARD THERMAL MAGNETIC MOLDED CASE CIRCUIT BREAKER, RATINGS AS INDICATED CT CURRENT TRANSFORMER, RATING AS INDICATED LIGHTNING ARRESTOR, RATINGS AS INDICATED GENERAL NOTES - ALL DRAWINGS: A. BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, BEDROOMS, CLOSETS, AND HALLWAYS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE CIRCUIT BREAKERS DESIGNED TO PROTECT THE BRANCH CIRCUIT PER NEC ARTICLE 210.12 . B. RECEPTACLES SHALL BE GFCI TYPE WHERE INSTALLED IN BATHROOMS, KITCHENS WHERE THE RECEPTACLE SERVES COUNTERTOP SURFACES, OUTDOORS, ROOFTOPS, AND WHERE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF THE OUTSIDE EDGE OF A SINK. C. UNLESS NOTED OTHERWISE, PROVIDE 15 AND 20 AMP SINGLE PHASE 120 VOLT CIRCUIT CONDUCTORS AS FOLLOWS: #12 AWG FOR CIRCUITS UP TO 100 FEET LONG, #10 AWG FOR CIRCUITS 101 TO 150 FEET LONG, #8 AWG FOR CIRCUITS 151 TO 250 FEET LONG. D. PROVIDE BRANCH CIRCUITS AS FOLLOWS: * BRANCH CIRCUITS IN DWELLING UNITS OF BUILDINGS 1.1, 2.1, 2.2, 2.3, 2.4, 4.1, 4.2, AND 4.3 SHALL BE NM CABLE. * BRANCH CIRCUITS FOR INTERIOR HOUSE LOADS OUTSIDE OF MECHANICAL ROOMS SHALL BE MC CABLE. * BRANCH CIRCUITS IN MECHANICAL ROOMS SHALL BE IN CONDUIT. E. CIRCUIT EXIT SIGNS TOGETHER FROM 20A-1P CIRCUIT BREAKER IN PANELBOARD THAT SERVES AREA LIGHTING. PROVIDE CIRCUIT BREAKER HANDLE LOCK. F. DUPLEX RECEPTACLES SHOWN IN DWELLING UNITS REPRESENT CODE REQUIRED QUANTITIES AND GENERAL SPACING PER NEC ARTICLE 210. DO NOT SCALE PLANS. VERIFY RECEPTACLE SPACING AND ADJUST LOCATIONS AS NECESSARY TO MEET NEC ARTICLE 210. WHERE STUD SPACING DOES NOT PERMIT NEC SPACING REQUIREMENTS, PROVIDE BRACKETS, STUDS, OR ADDITIONAL RECEPTACLES AS NECESSARY TO ACHIEVE NEC ARTICLE 210 REQUIREMENTS. G. PROVIDE TAMPERPROOF RECEPTACLES FOR ALL 15 AND 20 AMP RECEPTACLES IN DWELLING UNITS PER NEC ARTICLE 406.11. LOCATIONS INCLUDE ALL RECEPTACLES SPECIFIED IN NEC ARTICLE 210.52 (KITCHENS, DINING ROOMS, LIVING ROOMS, BEDROOMS, BATHROOMS, LAUNDRY AREA, CLOSETS, AND HALLWAYS). H. CIRCUIT EMERGENCY LIGHTING FIXTURES TO LOCAL AREA LIGHTING BRANCH CIRCUIT, AHEAD OF CONTROL DEVICES. I. PROVIDE NEMA 10-30R RECEPTACLE FOR EACH ELECTRIC CLOTHES DRYER OR COMBINATION WASHER/DRYER. J. PROVIDE NEMA 10-50R RECEPTACLE FOR EACH ELECTRIC RANGE. K. PROVIDE 15A RECEPTACLES FOR CIRCUITS SERVED FROM 15A CIRCUIT BREAKERS IN DWELLING UNITS. FIRE ALARM SYSTEM COMBINATION SMOKE DETECTOR AND CO DETECTOR WITH SOUNDER BASES a DATA OUTLET SB GFCI, AC, DUPLEX RECEPTACLE CCTV SYSTEM CAMERA FIRE ALARM SYSTEM SMOKE DETECTOR WITH SOUNDER BASES FIRE ALARM SYSTEM, FIRE ALARM CONTROL PANEL(S) FIRE ALARM SYSTEM, REMOTE ANNUNCIATOR FIRE ALARM SYSTEM, ADDRESSABLE SMOKE DETECTOR COMMUNICATION ROOM/CLOSET GROUND BAR TWC TIME WARNER CABLE FIRE ALARM SYSTEM, NOTIFICATION APPLIANCE, V=VISUAL ONLY, NUMBER = CANDELLA RATING, F = FUTURE DEVICE.V,15,FF A, 15,FF FIRE ALARM SYSTEM, NOTIFICATION APPLIANCE, HORN A=AUDIBLE ONLY, NUMBER = CANDELLA RATING FOR FUTURE DEVICE. LAP FIRE ALARM SYSTEM, CONNECTION TO SPRINKLER LOW AIR PRESSURE SWITCH PS FIRE ALARM SYSTEM, CONNECTION TO SPRINKLER PRESSURE SWITCH FIRE ALARM SYSTEM, CONNECTION TO SPRINKLER ELECTRIC WATER FLOW BELLF DS APARTMENT VISITOR DOOR ENTRY SYSTEM - TENANT STATION MS APARTMENT VISITOR DOOR ENTRY SYSTEM - MASTER STATION CO 1- SB ROOF MOUNTED PHOTOCELL CIRCUITED TO EXTERIOR LIGHTING CONTACTOR AND TIME SWITCH. 2 2 FIRE ALARM SYSTEM CONNECTION TO GARAGE LEVEL TEMPERATURE SENSOR 2