ELECTRICAL SYMBOL LIST AND
STANDARD NOTES
KSO
E0.01
ELECTRICAL SYMBOL LIST
EXISTING EQUIPMENT/WORK.
NEW EQUIPMENT/WORK.
3 REFERENCE TO DRAWING NOTE
EWC ELECTRIC WATER COOLER
AC ABOVE COUNTER
AFF ABOVE FINISHED FLOOR
GFI GFCI GROUND FAULT CIRCUIT INTERRUPTER TYPE RECEPTACLE
WG WIRE GUARD
WP WATERPROOF (OR) WEATHERPROOF
C CONDUIT
BRANCH CIRCUIT TO PANELBOARD, WHEN SHOWN,
LETTERING INDICATES PANELBOARD DESIGNATIONS.
QUANTITY OF ARROWHEADS INDICATE QUANTITY OF
BRANCH CIRCUITS. PROTECT EACH BRANCH CIRCUIT WITH
A 20 AMPERE, 1-POLE OVERCURRENT DEVICE UNLESS
OTHER SIZE INDICATED. TYPICAL DESIGNATION,
(2#12,1#12G-1/2"C,20A-1P.)
3
LLPB
5
ON BRANCH CIRCUITRY WHERE ONLY THE CIRCUIT NUMBER
IS SHOWN, CIRCUIT RECEPTACLES WITH THE SAME
NUMBER TO THE CIRCUIT INDICATED WITH A HOMERUN TO
EACH NUMBERED GROUP. CONNECT TO A 20A-1P CIRCUIT
BREAKER, OR AS NOTED FOR SPECIAL PURPOSE
RECEPTACLES.
32
B
811 4
ON BRANCH CIRCUITRY WHERE ONLY THE CIRCUIT NUMBER
IS SHOWN, CIRCUIT LUMINAIRES WITH THE SAME NUMBER
TO THE CIRCUIT INDICATED WITH A HOMERUN TO EACH
NUMBERED GROUP. CONNECT TO A 20A-1P CIRCUIT
BREAKER, OR AS NOTED.
114 22
DIAGRAM CIRCUIT DESIGNATION. REFER TO SCHEDULE ON
DIAGRAM.2
BRANCH CIRCUIT PANELBOARD. REFER TO PANEL BOARD
SCHEDULE.
J JUNCTION BOX
3
LIGHTING CONTROL SWITCH. LIGHTING WALL SWITCHES,
1 POLE IF NO NOTATION. 3=3 WAY, 4=4 WAY, K=KEY TYPE
LOWER CASE LETTER INDICATES CONTROL DESIGNATION.
OS OCCUPANCY SENSOR, CEILING MOUNTED.
OS OCCUPANCY SENSOR, WALL MOUNTED.
DUPLEX RECEPTACLE
QUAD RECEPTACLE
SPECIAL PURPOSE RECEPTACLE.
3 INDICATION OF GANGED DEVICES
LIGHTING FIXTURE
LIGHTING FIXTURE, WALL
xxEM
LIGHTING FIXTURE WITH DESIGNATION ENDING "EM "
CONTAINS INTEGRAL FLUORESCENT EMERGENCY POWER
UNIT
LIGHTING FIXTURE, FLUORESCENT STRIP
EMERGENCY LIGHTING FIXTURE, INTEGRAL BATTERY
EXIT LIGHT FIXTURE
EXIT LIGHT FIXTURE, WALL MOUNTED
M F1 EQUIPMENT CONNECTION, WITH DESIGNATION FROM
ELECTRIC EQUIPMENT AND CONTROL SCHEDULE
F1
LOCATION OF ONE OR MORE EQUIPMENT CONTROL
DEVICES AS SCHEDULED ON ELECTRIC EQUIPMENT AND
CONTROL SCHEDULE. DESIGNATION REFERS TO
EQUIPMENT CONTROLLED
DISCONNECT SWITCH, VOLTAGE AND AMPERE RATING TO
MATCH EQUIPMENT SERVED. REFER TO ELECTRIC
EQUIPMENT AND CONTROL SCHEDULE FOR FUSING
REQUIREMENTS.
D DOOR BUZZER
F FIRE ALARM SYSTEM, MANUAL PULL STATION
FIRE ALARM SYSTEM, NOTIFICATION APPLIANCE, HORN
STROBE. V=VISUAL ONLY. NUMBER = CANDELLA RATINGV, 75F
FIRE ALARM SYSTEM, THERMODETECTOR, COMBINATION
FIXED TEMPERATURE/RATE-OF-RISE, FIXED TEMPERATURE
RATING 135°F, UNLESS INDICATED OTHERWISE.
H
FIRE ALARM SYSTEM SMOKE DETECTOR. "DT" INDICATES
DUCT MOUNTED TYPE WITH REMOTE TEST STATION.
DT
S
ELECTRICAL SYMBOL LIST
F F
FIRE ALARM SYSTEM, MAGNETIC DOOR HOLDER,
INDIVIDUAL,WALL MOUNTED. SUBSCRIPT "F" INDICATES
FLOOR MOUNTED.
SH FIRE ALARM SYSTEM, CONNECTION TO SMOKE HATCH
FS FIRE ALARM SYSTEM, CONNECTION TO SPRINKLER FLOW
SWITCH. NUMBER INDICATES QUANTITY
TS1-
FIRE ALARM SYSTEM, CONNECTION TO SPRINKLER SYSTEM
TAMPER SWITCH. NUMBER INDICATES QUANTITY
PIV FIRE ALARM SYSTEM, CONNECTION TO SPRINKLER/
STANDPIPE SYSTEM PIV VALVE TAMPER SWITCH
WALL MOUNTED TELEPHONE OUTLET
WORKSTATION OUTLET LAYOUT. LETTER INDICATES TYPE,
NUMBER INDICATES BRANCH CIRCUIT NUMBER. REFER TO
DETAIL.a1
TELEVISION OUTLET W/RECEPTACLE. LETTER INDICATES
TYPE, NUMBER INDICATES BRANCH CIRCUIT NUMBER
REFER TO DETAIL.
1 aTV
FUSED DISCONNECT SWITCH, RATINGS AS INDICATED
STANDARD THERMAL MAGNETIC MOLDED CASE CIRCUIT
BREAKER, RATINGS AS INDICATED
CT CURRENT TRANSFORMER, RATING AS INDICATED
LIGHTNING ARRESTOR, RATINGS AS INDICATED
GENERAL NOTES - ALL DRAWINGS:
A. BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS,
LIVING ROOMS, BEDROOMS, CLOSETS, AND HALLWAYS SHALL BE PROTECTED BY A
LISTED ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE CIRCUIT BREAKERS
DESIGNED TO PROTECT THE BRANCH CIRCUIT PER NEC ARTICLE 210.12 .
B. RECEPTACLES SHALL BE GFCI TYPE WHERE INSTALLED IN BATHROOMS, KITCHENS
WHERE THE RECEPTACLE SERVES COUNTERTOP SURFACES, OUTDOORS, ROOFTOPS,
AND WHERE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF THE OUTSIDE EDGE OF A
SINK.
C. UNLESS NOTED OTHERWISE, PROVIDE 15 AND 20 AMP SINGLE PHASE 120 VOLT CIRCUIT
CONDUCTORS AS FOLLOWS: #12 AWG FOR CIRCUITS UP TO 100 FEET LONG, #10 AWG
FOR CIRCUITS 101 TO 150 FEET LONG, #8 AWG FOR CIRCUITS 151 TO 250 FEET LONG.
D. PROVIDE BRANCH CIRCUITS AS FOLLOWS:
* BRANCH CIRCUITS IN DWELLING UNITS OF BUILDINGS 1.1, 2.1, 2.2, 2.3, 2.4, 4.1, 4.2,
AND 4.3 SHALL BE NM CABLE.
* BRANCH CIRCUITS FOR INTERIOR HOUSE LOADS OUTSIDE OF MECHANICAL ROOMS
SHALL BE MC CABLE.
* BRANCH CIRCUITS IN MECHANICAL ROOMS SHALL BE IN CONDUIT.
E. CIRCUIT EXIT SIGNS TOGETHER FROM 20A-1P CIRCUIT BREAKER IN PANELBOARD THAT
SERVES AREA LIGHTING. PROVIDE CIRCUIT BREAKER HANDLE LOCK.
F. DUPLEX RECEPTACLES SHOWN IN DWELLING UNITS REPRESENT CODE REQUIRED
QUANTITIES AND GENERAL SPACING PER NEC ARTICLE 210. DO NOT SCALE PLANS.
VERIFY RECEPTACLE SPACING AND ADJUST LOCATIONS AS NECESSARY TO MEET NEC
ARTICLE 210. WHERE STUD SPACING DOES NOT PERMIT NEC SPACING REQUIREMENTS,
PROVIDE BRACKETS, STUDS, OR ADDITIONAL RECEPTACLES AS NECESSARY TO
ACHIEVE NEC ARTICLE 210 REQUIREMENTS.
G. PROVIDE TAMPERPROOF RECEPTACLES FOR ALL 15 AND 20 AMP RECEPTACLES IN
DWELLING UNITS PER NEC ARTICLE 406.11. LOCATIONS INCLUDE ALL RECEPTACLES
SPECIFIED IN NEC ARTICLE 210.52 (KITCHENS, DINING ROOMS, LIVING ROOMS,
BEDROOMS, BATHROOMS, LAUNDRY AREA, CLOSETS, AND HALLWAYS).
H. CIRCUIT EMERGENCY LIGHTING FIXTURES TO LOCAL AREA LIGHTING BRANCH CIRCUIT,
AHEAD OF CONTROL DEVICES.
I. PROVIDE NEMA 10-30R RECEPTACLE FOR EACH ELECTRIC CLOTHES DRYER OR
COMBINATION WASHER/DRYER.
J. PROVIDE NEMA 10-50R RECEPTACLE FOR EACH ELECTRIC RANGE.
K. PROVIDE 15A RECEPTACLES FOR CIRCUITS SERVED FROM 15A CIRCUIT BREAKERS IN
DWELLING UNITS.
FIRE ALARM SYSTEM COMBINATION SMOKE DETECTOR AND
CO DETECTOR WITH SOUNDER BASES
a
DATA OUTLET
SB GFCI, AC, DUPLEX RECEPTACLE
CCTV SYSTEM CAMERA
FIRE ALARM SYSTEM SMOKE DETECTOR WITH SOUNDER
BASES
FIRE ALARM SYSTEM, FIRE ALARM CONTROL PANEL(S)
FIRE ALARM SYSTEM, REMOTE ANNUNCIATOR
FIRE ALARM SYSTEM, ADDRESSABLE SMOKE DETECTOR
COMMUNICATION ROOM/CLOSET GROUND BAR
TWC TIME WARNER CABLE
FIRE ALARM SYSTEM, NOTIFICATION APPLIANCE, V=VISUAL
ONLY, NUMBER = CANDELLA RATING, F = FUTURE DEVICE.V,15,FF
A, 15,FF
FIRE ALARM SYSTEM, NOTIFICATION APPLIANCE, HORN
A=AUDIBLE ONLY, NUMBER = CANDELLA RATING FOR
FUTURE DEVICE.
LAP FIRE ALARM SYSTEM, CONNECTION TO SPRINKLER LOW AIR
PRESSURE SWITCH
PS FIRE ALARM SYSTEM, CONNECTION TO SPRINKLER
PRESSURE SWITCH
FIRE ALARM SYSTEM, CONNECTION TO SPRINKLER ELECTRIC
WATER FLOW BELLF
DS APARTMENT VISITOR DOOR ENTRY SYSTEM - TENANT
STATION
MS APARTMENT VISITOR DOOR ENTRY SYSTEM - MASTER
STATION
CO
1-
SB
ROOF MOUNTED PHOTOCELL CIRCUITED TO EXTERIOR
LIGHTING CONTACTOR AND TIME SWITCH.
2
2
FIRE ALARM SYSTEM CONNECTION TO GARAGE LEVEL
TEMPERATURE SENSOR
2