Loading...
HomeMy WebLinkAbout09-M4-43AUP UP DN OPEN TO ABOVE 1" HWS & HWR UP & 114" HWS & HWR DN 1" HWS & HWR UP & 114" HWS & HWR DN 12x4 UP W/FD 12x4 UP W/FD 12x4 UP W/FD UC U C 1 SPS T SPS 1 RANGE EXHAUST HOOD. FINAL CONN. BY MECH. (TYP.) 7"Ø TO HOOD. HOOD BY OTHERS. (TYP.) BEDROOM BEDROOM KITCHEN LIVING/ DINING RM HALLWAY BATH LIVING/ DINING RM BEDROOM KITCHEN BEDROOM LIVING/ DINING RM LIVING/ DINING RM BEDROOM BEDROOM KITCHEN KITCHEN BATH BATH BATH BATH BATH BEDROOM PTAC-4.3B-4 12x6 200 1 12x6 200 1 3 14x3 RETURN AIR DUCT WITHIN WALL. TERMINATE IN CEILING PLENUM W/ OPEN END. 14x3 200 A (TYP. 2) MOUNT AT FLOOR 57 PTAC-4.3B-3 1" HWS & HWR UP & 114" HWS & HWR DN 12x8 300 1 12x6 200 1 7 3 14x6 200 1 BATH U C U C T 1" HWS & HWR UP & 114" HWS & HWR DN PTAC-4.3B-2 12x8 300 A 14x6 200 1 7 3 F-1 F-1 F-1 F-1 4"Ø DRYER VENT W/ WALL CAP 4"Ø 4"Ø 4"Ø 4"Ø 4"ØWH-1 WH-1 2 SPS 2 SPS 9 9 4"Ø DRYER VENT. FINAL CONN. TO DRYER BY MECH. (TYP.) U C UC SPS 1 12x4 UP W/FD F-1 DRYER VENT W/ WALL CAP 4"Ø SPS 1 9 6x6 UP W/FD F-1 F-1 4"Ø 4"Ø WH-1 2 SPS DRYER VENT W/ WALL CAP 4"Ø PTAC-4.3B-1 14x6 200 1 12x6 200 1 14x14 700 A MOUNT AT FLOOR 12x8 300 1 7 3 SERVICE ACCESS PANEL DOOR SERVICE ACCESS PANEL DOOR SERVICE ACCESS PANEL DOOR SERVICE ACCESS PANEL DOOR 2 2 2 6x6 UP W/FD 6x6 UP W/FD 2 2 4 4 4 6x6 UP W/FD2 SPS 10 6x10 120 1 6x10 CUH-4.3B-1 1" HWS & HWR DN 2 UP UP OPEN TO BELOW DOWN DOWN 34" HWS & HWR UP & 1" HWS & HWR DN 12x6 UP W/FD & 12x4 DN 12x6 UP W/FD & 12x4 DN 12x6 UP W/FD & 12x4 DN 8x6 UP W/FD & 6x6 DN 8x6 UP W/FD & 6x6 DN U C U C T RANGE EXHAUST HOOD. FINAL CONN. BY MECH. (TYP.) 7"Ø TO HOOD. HOOD BY OTHERS. (TYP.) BEDROOM BEDROOM KITCHEN LIVING/ DINING RM HALLWAY BATH LIVING/ DINING RM BEDROOM KITCHEN BEDROOM LIVING/ DINING RM LIVING/ DINING RM BEDROOM BEDROOM KITCHEN KITCHEN BATH BATH BATH BATH BATH BEDROOM PTAC-4.3C-4 12x6 200 1 12x6 200 1 3 14x3 RETURN AIR DUCT WITHIN WALL. TERMINATE IN CEILING PLENUM W/ OPEN END. 14x3 200 A (TYP. 2) MOUNT AT FLOOR 57 BATH U C U C T PTAC-4.3C-2 12x8 300 A 12x6 200 1 14x6 200 1 7 3 F-1 F-1 F-1 F-1 4"Ø DRYER VENT W/ WALL CAP 4"Ø 4"Ø 4"Ø 4"Ø 4"ØWH-1 WH-19 9 4"Ø DRYER VENT. FINAL CONN. TO DRYER BY MECH. (TYP.) U C UC 6x6 UP W/FD & 6x6 DN F-1 DRYER VENT W/ WALL CAP 4"Ø 9 6x6 UP W/FD & 6x6 DN F-1 F-1 4"Ø 4"Ø WH-1 DRYER VENT W/ WALL CAP 4"Ø PTAC-4.3C-1 14x6 200 1 12x6 200 1 14x14 700 A MOUNT AT FLOOR 12x8 300 1 7 3 SERVICE ACCESS PANEL DOOR SERVICE ACCESS PANEL DOOR SERVICE ACCESS PANEL DOOR SERVICE ACCESS PANEL DOOR 3 4" HWS & HWR UP & 1" HWS & HWR DN 34" HWS & HWR UP & 1" HWS & HWR DN PTAC-4.3C-3 12x8 300 1 12x6 200 1 7 3 14x6 200 1 34" HWS & HWR UP & 1" HWS & HWR DN 2 2 12x6 UP W/FD & 12x4 DN 2 2 2 2 4 4 4 1/4"=1'0" BUILDING 4.3 - LEVEL C2 1/4"=1'0" BUILDING 4.3 - LEVEL B1 DRAWING NO.: DRAWN BY: DATE: SHEET TITLE: PROJECT TITLE: COLLEGETOWN TERRACE APARTMENTS ITHACA, NY NOVARR MACKESEY DEVELOPMENTPROFESSIONAL LICENSE NUMBER: NEW YORK STATE SEAL: a r c h i t e c t s ikon.5 PROJECT NO.:P58.00 VERSIONS NO. DATE DESCRIPTION CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL ENGINEER: LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER: 12923 NORTH PROJECTJULY 1, 2011 1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS KEY PLAN 2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS ADDENDUM - 1 BUILDING 4.3 FLOOR PLAN - LEVEL B, LEVEL C PR M2.43A GENERAL NOTE: A. PROVIDE 6x6 ACCESS DOOR FOR SERVICE OF STATIC PRESSURE SENSOR (SPS).RETURN AIR PATH OPENING AT TOP OF PTAC CLOSET. OPENING EXTENDS FULL WIDTH OF CLOSET FROM 7'-6" TO BOTTOM OF STRUCTURE. 16x10 RETURN AIR DUCT TERMINATES ABOVE CLOSET CEILING. COORDINATE EXACT LOCATION OF HWS & HWR WITH PTAC ACCESS DOOR, COIL CONNECTIONS, CONDENSATE RISER AND ELECTRICAL. DO NOT BLOCK RETURN AIRFLOW OPENING WITH RISERS. CORRIDOR CUH TEMPERATURE & VENTILATION CONTROLLER. EXTEND CONTROL CONDUCTORS TO CUH AND AUTOMATIC RELIEF DAMPER ACTUATOR. RIGID DRYER EXHAUST DUCT ABOVE CEILING & CONNECT TO VENT CAP. FLEX DUCT BELOW CEILING. PROVIDE FIRE DAMPER AT CEILING/FLOOR PENETRATION. FIRE DAMPER SHALL BE TYPE B WITH SLEEVE EXTENDING FROM BELOW CEILING TO ABOVE FLOOR. 5 6 7 1 2 KEYED NOTES: (NOT ALL NOTES USED ON EACH PLAN) STATIC PRESSURE SENSOR AT BOTTOM OF RANGE HOOD EXHAUST RISER. EXTEND SENSOR WIRING TO CONTROLLER ON LEVEL E. TYPICAL OF ALL RANGE HOOD EXHAUST RISERS. STATIC PRESSURE SENSOR AT BOTTOM OF BATHROOM EXHAUST RISER. EXTEND SENSOR WIRING TO CONTROLLER ON LEVEL E. TYPICAL OF ALL BATHROOM EXHAUST RISERS. PTAC TOP PLENUM AND DUCT DISTRIBUTION, SEE 1, 2, 3 / M5-03. OFFSET BRANCH CONNECTIONS TO RISER. 3 4 8 9 102 2 2