Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20210315 - 430-444 West State MLK Street - Electrical Set
3AOSSPSWITCHDUPLEX RECEPTACLE QUAD RECEPTACLEEXIT SIGN -CEILINGEMERGENCY LIGHTEXIT SIGN -WALL#G:GFCIA:Above CounterW:WeatherproofNEW CONCEALED WIRINGSURFACE MOUNT# Indicates Quantity of Jacks if More than OneCLG: MOUNT TO CEILINGAC:MOUNT ABOVE CEILINGDATA OUTLET3:3 Way4:4 WayOS:Occupancy SensorVS:Vacancy SensorKP:KeypadLINEAR FIXTUREPANELBOARD-RECESSEDPANELBOARD-SURFACELEGENDCEILING OCCUPANCY SENSORNEW SURFACE RACEWAYSECURITY SYSTEM REMOTE EMERGENCY HEADDOOR OPERATORDOWNLIGHTWALL WASHCARD READERCRCALL BUTTONDOOR OPERATOR PUSH BUTTONPDOOR OPERATORDODOOR CONTACTDCREQUEST TO EXITREXKEYPADKPMOTION SENSORMSACCESS CONTROL PANELAPELECTRIC STRIKEESMAGNETIC STRIKEMS208 VOLT RECEPTACLEPENDANT LIGHTCAMERAFLOOR BOXCORNER OCCUPANCY SENSORHORN/STROBE / CandelaSTROBE / CandelaPULL STATIONSMOKE DETECTORP: PhotoelectricI: IonizationD: DuctH/S: Heat & SmokeCO: Carbon Monoxide## Indicates Total Quantity of Jacks, Including (1) VoiceVOICE/DATA OUTLETFIRE ALARM CONTROL PANELFACPDOOR HOLDERREMOTE ANNUNCIATORRA7575EMERGENCY COMMUNICATIONS PANELECPEMERGENCY CALL STATIONECMODULE 1(DIMU8)INPUT AINPUT BZONE 1 (FITNESS CENTER)ZONE 2 (FITNESS CENTER)ZONE 12 (MAILROOM)ZONE 10 (LOBBY)ZONE 18 (LOBBY)ZONE 25 (RESIDENT LOUNGE)MODULE 3(LV8)INPUT AINPUT BZONE 3 (FITNESS CENTER)ZONE 4 (YOGA)ZONE 5 (ELEVATOR LOBBY)ZONE 7 (HALLWAY)ZONE 8 (HALLWAY)ZONE 9 (LOBBY)ZONE 11 (VESTIBULE)ZONE 13 (MAILROOM)MODULE 2(DIMU8)INPUT AINPUT BZONE 28 (RESIDENT LOUNGE)ZONE 29 (RESIDENT LOUNGE)ZONE 22 (RESIDENT LOUNGE)ZONE 6 (ELEVATOR LOBBY)MODULE 4(LV8)INPUT AINPUT BZONE 14 (LOBBY)ZONE 15 (LOBBY)ZONE 17 (LOBBY)ZONE 19 (LOBBY)ZONE 20 (RESIDENT LOUNGE)ZONE 21 (RESIDENT LOUNGE)ZONE 23 (RESIDENT LOUNGE)ZONE 24 (RESIDENT LOUNGE)ZONE 16 (LOBBY)MODULE 5(LV8)INPUT AINPUT BZONE 26 (RESIDENT LOUNGE)ZONE 27 (RESIDENT LOUNGE)ZONE 30 (RESIDENT LOUNGE)ZONE 31 (LEASING OFFICE)ZONE 32 (PACKAGE ROOM)ZONE 33 (PET SPA)ZONE 34 (BIKE ROOM)ZONE 35 (TRASH ROOM)HP-1/51INPUT 120V CIRCUITSLIGHTING CONTROL ZONESZONE 36 (BUILDING EXTERIOR)HP-1/52HP-1/53HP-1/54HP-1/55HP-1/56HP-1/57HP-1/58HP-1/59ZONE 37 (BUILDING EXTERIOR)ZONE 38 (BUILDING EXTERIOR)HP-1/60ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATEDESCRIPTIONAs indicatedNOTES, SCHEDULE &LEGENDE001Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECTLIGHTING FIXTURE SCHEDULEType Manufacturer Model Description Apparent Load CommentsAA1 Sistemalux LOG3-R-T-NC-H-930-AFL-VOLT-01-D10 Recessed Adjustable Angle Downlight 13 WACL1 Inter-lux WG-20ZCG-RBT-S-LENGTH-H-930-D010-P4-LL45C-W Cove Graze LED 0 W Rated at 10 W/ft. Lengths to be verified in field.ACL2 Inter-lux WG-20LWW-RBT-S-A-M-930-D010-OD-W Recessed LED Linear Wall Wash 0 W Rated at 6.4 W/ft. Lengths to be verified in field.ACLC Inter-lux WG-20ZCG-RBT-S-LENGTH-H-927-D010-P4-LL45C-W Recessed LED Linear Wall Wash, 2700K 180 W Rated at 10 W/ft. Lengths to be verified in field.AD1 Inter-lux WG-100RPTDLF-RBT-M-930-D010-RRC-MPL-65-W-WL Recessed LED Downlight, Wet Rated 8 WAD2 Inter-lux WG-100RPTDLF-RBT-M-930-D010-RRC-MPL-41-W Recessed LED Downlight 8 WAD3 Omnilight ORB-30-S-BN-MC LED Puck Light 4 WAD4 Omnilight ORB-30-S-BN-MC LED Puck Light 4 WAD5 Inter-lux WG-100RPTD-RBT-M-930-D010-RRC-RSO-110-W Recessed LED Downlight 15 WAF1 AFX RVF162600L30D2BKGD Surface Mount LED 31 WAF2 marset Plaff-on! 50 LED SMD 36W 3000K Surface Mount LED 36 W Provide with 3000K temperature rating and 0-10V dimming.AF3 Kuzco FM43518-BK LED 18" Round Surface Mount, Black 30 WAF4 Kuzco FM43522-BK LED 22" Round Surface Mount, Black 42 WAF5 AFX RVF121400L30D2WHBK Reveal LED Flush Mount 18 WAL1 Inter-lux WG-20LRR-RPT-S-LENGTH-M-930-D010-LL45W-W Recessed LED Linear 51 W Rated at 6.4 W/ft. Lengths to be verified in field.AL2 tivoli TPLE-SB-I-30-24-MINI-CHAN-SLV-6.5-MINI-LNS-OP-6.5-MINI-EC-(ENDCAPS)-MINI-MTBKSurface Mount Linear LED 0 W Rated at 3.2 W/ft. Fixture lengths to be verified in field. Refer to Architectural drawings formounting heights. Provide ADUL Series Class 2 Transformer (ADUL-120-1-4-24-DOT) tosupport no more than 30 ft of LED tape per channel. Provide DIM-LD-010 dimmer. Mountdrivers and dimmers in package room.AL3 tivoli TPLE-SB-I-30-24-MINI-CHAN-SLV-6.5-MINI-LNS-OP-6.5-MINI-EC-(ENDCAPS)-MINI-MTBKSurface Mount Linear LED 0 W Rated at 3.2 W/ft. Lengths to be verified in field. Provide ADUL Series Class 2Transformer (ADUL-120-1-4-24-DOT) to support no more than 30 ft of LED tape perchannel. Provide DIM-LD-010 dimmer. Mount drivers in package room. Lengths to beverified in field.AL4 LEDLinear VARIOLED 0002-NEXUSHD10-W9-30-LO-(CONNECTOR)-E-FMP-LENGTH TO BEVERIFIED-IP20Surface Mount Linear LED 0 W Rated at 2.9 W/ft. Provide D-REM-030W-DIM-UNV-IP65 driver for each instance of fixturetype. Lengths to be verified in field.AL5 tivoli TPLE-SB-I-30-24-MINI-CHAN-SLV-6.5-MINI-LNS-OP-6.5-MINI-EC-(ENDCAPS)-MINI-MTBKSurface Mount Linear LED 16 W Rated at 3.2 W/ft. Fixture lengths to be verified in field. Refer to Architectural drawings formounting heights. Provide ADUL Series Class 2 Transformer (ADUL-120-1-4-24-DOT) tosupport no more than 30 ft of LED tape per channel. Provide DIM-LD-010 dimmeALP1 Sonneman 2818.25-6 (BLACK) Decorative Linear Pendant 36 W Locate remote driver in accessible/serviceable location in Package Room 102. Refer toArch elevations for mounting height.ALP2 Sonneman 22QKCL02120PHA (BLACK) Ola Double Linear LED Pendant Decorative Linear Pendant 24 W Refer to Arch elevations for mounting height.ALP2_ALT1 Sonneman 2839.25 (BLACK) Morii Pendant Decorative Linear Pendant 34 W Refer to Arch elevations for mounting height.ALP2_ALT2 Seed Design SLD-3981PL (BLACK) Mumu Pendant XL Decorative Linear Pendant 48 W Refer to Arch elevations for mounting height.ALR1 LEDLinear VarioLED 1300-Nexus HD15-W9-30-S-OP-B-FMC-IP20 SurfaceMount Shallow LED Linear 28 W Rated at 4.7W/ft. Provide D-REM-030W-DIM-UNV-IP65 driver for each instance of fixturetype. Lengths to be verified in field.AP1A Tooy TOY959218 (9.8" diameter) Decorative Pendant, Copper Finish, BlackSmoke Shade12 W Refer to Arch elevations for mounting height. Provide with 3000K color temperature.AP1A_ALT1 DCW Editions Here Comes the Sun Pendant (Medium) Decorative Pendant 25 W Refer to Arch elevations for mounting height. Provide dimmable LED A19 3000K (25Wmax) bulb for each instance.AP1B Tooy TOY959214 (13.8" diameter) Decorative Pendant, Copper Finish, BlackSmoke Shade12 W Refer to Arch elevations for mounting height. Provide with 3000K color temperature.AP1B_ALT1 DCW Editions Here Comes the Sun Pendant (Large) Decorative Pendant 40 W Refer to Arch elevations for mounting height. Provide dimmable LED A19 3000K (40Wmax) bulb for each instance.AP2 Secto Design SEC856338 Octo 4241 Pendant, Black Laminated Birch,17.7"22 W Refer to Arch elevations for mounting height. Provide 22W LED E26 3000K bulb for eachinstance of fixture.AP3 Sonneman 2656.25A 9-Light LED Pendant, Black Finish 60 W Refer to Arch elevations for mounting height.AP3_ALT1 Kuzco PD12732-BK LED Pendant 145 W Refer to Arch elevations for mounting height. Provide ELV dimmer for fixture.AP4A Graypants Disc16 Pendant Natural GP-141 Decorative Pendant 15 W Refer to Arch elevations for mounting height. Provide LED A19 3000K bulb (15W max) foreach instance of fixture.AP4B Graypants Moon10 Pendant Natural GP-161 Decorative Pendant 15 W Refer to Arch elevations for mounting height. Provide LED A19 3000K bulb (15W max) foreach instance of fixture.AP4C Graypants Moon14 Pendant Natural GP-162 Decorative Pendant 15 W Refer to Arch elevations for mounting height. Provide LED A19 3000K bulb (15W max) foreach instance of fixture.AW1 Sonneman 2711.72-WL Decorative Wall Sconce 12 W Provide (2) 3000K LED Replacement bulbs. Refer to Arch elevations for mounting height.AW1_ALT1 Access 20407LEDD-BL/GD Decorative Wall Sconce 12 W Refer to Arch elevations for mounting height.AW2 Birchwood Lighting HAI-LED-225-1B-HLO-30-8-FB-FW-D1-RAS-1TR-R-FB-5 Round Linear LED 47 W Provide with 1TR Trim & 1.25" Knuckle selection, with 6" Arm Length.AWC Alva (Auberge) AU- R15W-27-9-RE7W12H-RV-DP12A-BLK LED Wall Sconce 15 W Refer to Arch elevations for mounting height.AWC_B Alva (Auberge) AU- R15W-27-9-RE7W12H-RV LED Wall Sconce 15 W Refer to Arch elevations for mounting height.CLC tivoli TPLE-VHO-I-27-24-DWAR-CHAN-SLV-6.5-DWAR-LNS-OPL-6.5 Recessed Cove Light 0 W Rated 4.5 W/ft. Lengths to be verified in field. Provide fixture with modified channel withlight provided only on one side. Refer to Electrical drawings for direction of light source.E1 WAC Lighting WS-W15710-BK Outdoor LED Wall Sconce, Black Finish 12 WE2 WAC Lighting WS-W15708-BK Outdoor LED Wall Sconce, Black Finish 12 W Refer to Arch elevations for mounting height. Controlled by switch in dwelling unit.E3 WAC Lighting 5111-27BK LED Flood Light 9 W Refer to Architectural drawings for mounting locations and heights. Provide transformer.E4 Lithonia OLMF-P1-40K-120V-DDB LED Flood Light 28 W Refer to Arch elevations for mounting height. Fixtures are for emergency operation only.E5 Tokistar Lighting EXBK-12-UBWW-G14-F LED String lights 29 W Refer to Arch elevations for mounting height. Provide T24-300 transformer, mount inaccessible location. Provide EX-MDA-BK and catenary cable to string fixtures acrossalleyway. Coordinate locations of poles to support cable with landscape architects.E6 DBF AC85-265V 15W LED Downlight, Wet Rated 15 W Fixtures to be controlled by centralized lighting controller. Operations shall conform withrequirements of IECC for outdoor light fixture operation.EX1 Lithonia LRP W 1 RC 120/277 TM Ceiling-mount Architectural Exit Sign, RedLetters on Clear5 W Refer to planset for direction arrows.EX2 Lithonia LRP W 2 RMR DA 120/277 TM Ceiling-mount Architectural Exit Sign, RedLetters on Mirror5 W Refer to planset for direction arrows.EX3 Lithonia LQM S W 3 R 120/277 SD Versatile-mount Exit Sign, Red Letters onWhite Body, Self Diagnostics5 W Refer to planset for direction arrows.P RAB Lighting VXBRLED13DG LED Vaporproof Fixture 15 WR Lamar LED TTU48M-40EM Wall Mount Strip light 29 W Controlled by integrated motion sensor. Fixtures shall dim to 25% output after time delayof 5 minutes.S1 Day-Brite CFI by Signify FSS430L830-UNV-DIM 4' Linear LED 32 W Fixture to be surface mounted, except for indicated on planset. Refer to keyed notes formounting heights, where applicable. Where fixture is to be suspended, provide accessoryFKR-126.S2 Day-Brite CFI by Signify FSS220L830-UNV-DIM 2' Linear LED 17 WT GE Evolve ECLS-01-0-T5-SM-7-30-A-A-SM-WHTE Canopy LED Soffit 29 W Fixture shall be supplied with integrated motion sensor and photocell. Fixtures shall dim to20% output during inactive periods.UB Liton LCMPD5RW-T27 LED Ceiling Disk, White, 2700K 11 W Refer to Architectural drawings for spacing and placement.UC Liton LCMPD5RW-T27 LED Ceiling Disk, White, 2700K 11 W Refer to Architectural drawings for spacing and placement.UE Liton LCMPD5RW-T27 LED Ceiling Disk, White, 2700K 11 W Refer to Architectural drawings for spacing and placement.UH Liton LCMPD5RW-T27 LED Ceiling Disk, White, 2700K 11 W Refer to Architectural drawings for spacing and placement.UK Liton LCMPD5RW-T27 LED Ceiling Disk, White, 2700K 11 W Refer to Architectural drawings for spacing and placement.UP EGLO TOROTRETO 62547A LED Slim Pendant 10 W Refer to Architectural drawings for spacing and placement.US Liton LCMPD5RB-T27 LED Ceiling Disk, Black, Wet rated 11 W Refer to Architectural drawings for spacing and placement.UV MODCREATIONStudio 5469 Bathroom Vanity Fixture 18 W Provide (2) 2700K LED bulbs. Refer to Arch drawings for mounting height.LIGHTING CONTROL NOTES1. ALL OCCUPANCY/VACANCY SENSORS SHALL BE MANUALLY ADJUSTED TO EXTINGUISH LIGHTS AFTER A PERIOD OF 5 MINUTES OF INACTIVITY.2. STAIRWELL LIGHT FIXTURES HAVE INTEGRATED MOTION SENSORS. REFER TO LIGHT FIXTURE SCHEDULE FOR CONTROL SETTINGS.3. OCCUPANCY SENSORS SHALL CONTROL ALL HALL OR ROOM LIGHTING, UNLESS OTHERWISE NOTED. WHERE FIXTURES ARE TO REMAIN CONSTANTLY ILLUMINATED, UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.4. ALL EMERGENCY LIGHTING AND EXIT SIGNAGE SHALL BE FED FROM GENERATOR DISTRIBUTION PANEL.5. LIGHTS DESIGNATED WITH “EM”ARE TO PROVIDE EMERGENCY EGRESS LIGHTING. WHERE CONTROLLED BY CRESTRON CONTROLLER OR LOCAL SWITCHING/OCCUPANCY CONTROL, PROVIDE BODINE GTD20A TRANSFER SWITCH/LIGHTING CONTROL DEVICES FOR EACH ZONE TO ALLOW BYPASSING OF CONTROLLER UPON LOSS OF NORMAL POWER. ELSEWHERE, FIXTURES ARE POWERED DIRECTLY FROM GENERATOR DISTRIBTUION PANEL.6. CONTROL OF EXTERIOR LIGHTING ZONE 36, EGRESS AND SITE LIGHT FIXTURES SHALL HAVE DAYLIGHT SHUTOFF AND MOTION DETECTION CONTROLS. LIGHT FIXTURES SHALL DIM TO 50% WHEN NO ACTIVITY HAS BEEN DETECTED FOR MORE THAN 5 MINUTES. LIGHTS SHALL ALSO DIM TO 50% BETWEEN MIDNIGHT AND 6AM. EXTERIOR LIGHTING CONTROLS SHALL CONFORM TO 2020 ENERGY CONSERVATION CODE OF NYS SECTION C405.2.6.LIGHT FIXTURE SCHEDULE NOTES 1. PROVIDE SUBMITTAL FOR EACH LIGHT FIXTURE FOR REVIEW BY OWNER'S ENERGY CONSULTANT.2. FOR ANY SUBMITTED FIXTURE WITH SCREW-IN LAMPS, EC SHALL PROVIDE LED LAMPS AS APPROVED BY OWNER, ENGINEER, AND ENERGY CONSULTANT.3. ALL LIGHTING ON FIRST FLOOR TO BE 3000K, UNLESS OTHERWISE NOTED. LIGHTING IN DWELLING UNITS AND SUPPORTING SPACES TO BE 2700KUNLESS OTHERWISE NOTED.4. CONTRACTOR TO PROVIDE ALTERNATIVE PRICING FOR ALL FIXTURES MARKED "ALT#".12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SETENERGY CODE COMPLIANCE NOTES1. PROJECT DOES NOT CONTAIN ANY DAYLIGHTING SIDELIT OR TOPLIT ZONES.2. REFER TO LIGHTING CONTROL NOTES ABOVE AND TO LIGHT FIXTURE SCHEDULE FOR INDIVIDUAL FIXTURE CONTROL DETAILS.No Scale1LIGHTING CONTROLLER ZONESGAS SERVICE ALTERNATE1. IF GAS SERVICE IS PROVIDED TO BUILDING, CONTRACTOR SHALL PROVIDECARBON MONIXIDE DETECTION IN COMPLIANCE WITH SECTION 915 OF THE FIRE CODE OF NEW YORK STATE.1111111 5000A-3P 208Y/120V 3PH-4W MAIN SERVICE DISCONNECT600-3PCT CABHOUSE1600-3P800A MB208Y-120V4W-3PHMAIN HOUSE PANEL "MHP"UNDERGROUND TO PAD MOUNTED TRANSFORMERFIRST FLOORAPT PANEL125A MLO208/120V1PH-3W24SP600A 3PH TERMINAL BLOCK (BOD: SQD EZM3600TB)225A 5-METER SOCKET STACK, 800A RATED HORIZONTAL BUSBAR (BOD: SQD EZMH315225), TYPICAL OF (6). EACH APARTMENT FEED TO BE PROTECTED BY 100A-2P BREAKER.225A 4-METER SOCKET STACK, 800A RATED HORIZONTAL BUSBAR (BOD: SQD EZMH314225), TYPICAL OF (1). EACH APARTMENT FEED TO BE PROTECTED BY 100A-2P BREAKER.SECOND FLOORTHIRD FLOOR600-3P600-3P600-3P600A 3PH TERMINAL BLOCK (BOD: SQD EZM3600TB)225A 5-METER SOCKET STACK, 800A RATED HORIZONTAL BUSBAR (BOD: SQD EZMH315225), TYPICAL OF (6). EACH APARTMENT FEED TO BE PROTECTED BY 100A-2P BREAKER.225A 4-METER SOCKET STACK, 800A RATED HORIZONTAL BUSBAR (BOD: SQD EZMH314225), TYPICAL OF (1). EACH APARTMENT FEED TO BE PROTECTED BY 100A-2P BREAKER.FOURTH FLOOR600A 3PH TERMINAL BLOCK (BOD: SQD EZM3600TB)225A 5-METER SOCKET STACK, 800A RATED HORIZONTAL BUSBAR (BOD: SQD EZMH315225), TYPICAL OF (5). EACH APARTMENT FEED TO BE PROTECTED BY 100A-2P BREAKER.225A 4-METER SOCKET STACK, 800A RATED HORIZONTAL BUSBAR (BOD: SQD EZMH314225), TYPICAL OF (1). EACH APARTMENT FEED TO BE PROTECTED BY 100A-2P BREAKER.FIFTH FLOOR600A 3PH TERMINAL BLOCK (BOD: SQD EZM3600TB)225A 6-METER SOCKET STACK, 800A RATED HORIZONTAL BUSBAR (BOD: SQD EZM315225), TYPICAL OF (5). EACH APARTMENT FEED TO BE PROTECTED BY 100A-2P BREAKER.225A 6-METER SOCKET STACK, 800A RATED HORIZONTAL BUSBAR (BOD: SQD EZM314225), TYPICAL OF (1). EACH APARTMENT FEED TO BE PROTECTED BY 100A-2P BREAKER.225A 3-METER SOCKET STACK, 800A RATED HORIZONTAL BUSBAR (BOD: SQD EZMH313225), TYPICAL OF (1). EACH APARTMENT FEED TO BE PROTECTED BY 100A-2P BREAKER.APT PANEL125A MLO208/120V1PH-3W24SPTYPICAL OF (34) PANELSAPT PANEL125A MLO208/120V1PH-3W24SPAPT PANEL125A MLO208/120V1PH-3W24SPTYPICAL OF (34) PANELSAPT PANEL125A MLO208/120V1PH-3W24SPAPT PANEL125A MLO208/120V1PH-3W24SPTYPICAL OF (32) PANELSAPT PANEL125A MLO208/120V1PH-3W24SPAPT PANEL125A MLO208/120V1PH-3W24SPTYPICAL OF (29) PANELSROOF800A MB208Y/120V3PH-4WCOMMERCIAL SPACE 1 PANEL"CP1"800A MB208Y/120V3PH-4WCOMMERCIAL SPACE 2 PANEL"CP2"800A MB208Y-120V3PH-4WCOMMERCIAL SPACE 3 PANEL"CP3"1200A MB208Y-120V4W-3PHROOF PANEL "P-ROOF"HOUSEPANEL"HP-2"225A MLO208/120V3PH-4WHOUSEPANEL"HP-4"225A MLO208Y/120V3PH-4WFEED FROM LUGS ON HOUSE CT CABINET IN MAIN SWITCH BOARD40KW EMERGENCY DIESEL GENERATOR208Y/120V 3PH-4WGEN ATS150A208Y/120V3PH-4WELECTRIC ROOM 122ELEVATOR 1CONTROLLER15HP MOTOR60A-3P UNFUSED DISCONNECT AT TOP OF HOISTWAYGEN PANEL150A208Y/120V3PH-4W60A-3P FUSED DISCONNECT60A-3P FUSED SHUNT-TRIP DISCONNECTELEVATOR 2CONTROLLER15HP MOTOR60A-3P UNFUSED DISCONNECT AT TOP OF HOISTWAYFEEDER SCHEDULEALL WIRE SIZES AWG, ALL WIRING CU UNLESS OTHERWISE INDICATEDSYMPER PHASENEUTRALEGCCONDUITABBBLDDBFFFFGHA(12) 750MCM AL(12) 750MCM AL-4"B(2) 500MCM AL(2) 500MCM AL#2/0 AL3"C(2) 250MCM AL(2) 250MCM AL#1 AL2-1/2"D(1) 300MCM AL(1) 300MCM AL#2 AL3"E(4) 500MCM AL(4) 500MCM AL250M AL3"F(1) #4(1) #4#81-1/2"G(1) #3/0(1) #3/0#62"H(1) #1/0(1) #1/0#62"JJ(1) #1(1) #1#8SER CABLEEJJJNOTE: ALL WIRE/CABLE SIZES SHOWN ON DRAWINGS ARE SIZED BASED ON FUSE OR BREAKER SIZE. CONTRACTOR TO VERIFY SUFFICIENT CONDUCTOR SIZE FOR VOLTAGE DROP BASED ON FINAL CONDUCTOR LENGTH FOR EACH SERVICE OR CIRCUIT. IF ALUMINUM CONDUCTORS ARE USED IN PLACE OF COPPER CONDUCTORS, WIREAND CONDUIT SIZED SHALL BE BASED ON NEC ALLOWABLE AMPERAGES FOR ALUMINUM CONDUCTORS.HTELECOM ROOM 118GYM PANEL"P-GYM"225A MLO208/120V3W-1PHHOUSE PANEL "HP-1"400A MLO208Y/120V4W-3PHCKLK(1) #3/0(1) #3/0-2"L(4) 400MCM AL(4) 400MCM AL#3/0 AL2-1/2"GENERAL NOTES1. WHERE FEEDERS TO APARTMENTS PANELS ARE NOT UPSIZED FOR VOLTAGE DROP, 125A METER SOCKETS MAY BE USED.DHW PANEL "P-DHW"400A MLO208Y/120V3PH-4WCTO PANEL P-ROOFECT CAB& METERLCT CAB& METERLCT CAB& METERM(6) 400MCM AL(6) 400MCM AL#4/0 AL2-1/2"LLLBICYCLE ROOM 115FITNESS CENTER 1081600-3P800-3P800-3P800-3PTO CT CABINETS IN TELECOM ROOM 118TO SWITCHBOARD IN ELECTRIC ROOM 122SERVICE DISCONNECT 6ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION3/8" = 1'-0"ELECTRICAL RISERDIAGRAME002Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECTNo Scale1ELECTRICAL RISER12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET CR CR1CRCRCRCR1 1 1 1AC 11111ACACTV4AC4000A 208Y/120V MAIN SERVICE DISCONNECTAPARTMENT SERVICE BREAKER SECTIONSHOUSE METER & CT CABINET/1E404/1E403/1E405/1E402/1E401/1E401/1E402/1E401YOGASTUDIO109RESIDENTLOUNGE107PET RELIEFAREA111PET SPA110RESTROOM112RESTROOM113ELEVATORLOBBY106PACKAGEROOM102MAIL ROOM103TRASHROOM116ELEV 2ELEV 1CENTRALSTAIRTELECOMROOM118UTILITYCORRIDOR117ELECTRICROOM12240KW DIESEL GENERATOR 208/120V 3PH-4WLEVEL 2 ENCLOSUREGENERATOR SETBACKBOLLARD, TYP1GEN TRANSFER SWITCHP-GENMHPELEVATOR DISCONNECTSFITNESSCENTER108COMMERCIALTENANTSPACE119LOBBY101VESTIBULE100WATERSERVICEROOM105LEASINGOFFICE1042FACPHP-1P-GYMBICYCLEROOM115EXITCORRIDOR114EXITCORRIDOR125STORAGE130EAST STAIR123STORAGE123BSTORAGE124BAPPROXIMATE ROUTING OF GENERATOR EXHAUST TO CHASE, EXTENDING TO ROOF3444"x4"JUNCTION/ PULLBOX4"x4"JUNCTION/ PULLBOXERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION3/32" = 1'-0"1ST FLOOR POWER &DATAE101Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT3/32" = 1'-0"1FIRST FLOOR - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 PROVIDE 8" CONCRETE PAD FOR GENERATOR. PAD SHALL EXTEND 6" FROM EDGE OF GENERATOR ALL AROUND.2 REFER TO LANDSCAPE DRAWINGS FOR BOLLARD DETAILS AND EXACT LOCATIONS.3 PROVIDE 3" DIAMETER BLACK STAINLESS STEEL PIPE WRAPPED IN 2" DURABACK INSULATION FOR GENERATOREXHAUST. COORDINATE ROUTING THROUGH CHASE WITH FRAMING. PROVIDE HILTI C-BJ-7005 WHERE IT PENETRATESRATED CEILING ABOVE GARAGE. PROVIDE THIMBLE WHERE PIPE PENETRATES ROOF.4 PROVIDE 1" PVC CONDUIT UNDERGROUND FROM PANEL MHP TO JUNCTION/PULL BOX INDICATED. INSTALL PULLSTRING FOR FUTURE INSTALLATION OF EV CHARGING STATION.E101 GENERAL NOTES1. REFER TO DRAWING E401, E403 & SPECIFICATION SECTION 087100 FOR ACCESS CONTROLS INFORMATION. BUILDING SECURITY TO BE PROVIDED BY OTHERS.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111 HP-2/1E406/1E410/1E406/1E407/1E409/1E406/1E407/1E408EZM3CORNEREZM3EXT800A TERMINAL BLOCK5-METER STACK (TYP OF 6)4-METER STACK (TYP OF 1)DATA DISTRIBUTIONAPPROXIMATE ROUTING OF GENERATOR EXHAUST THROUGH CHASE, EXTENDING TO ROOF1ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION3/32" = 1'-0"2ND FLOOR POWER &DATAE102Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT3/32" = 1'-0"1SECOND FLOOR - POWER & DATAE102 GENERAL NOTES1. REFER TO DRAWING E401, E403 & SPECIFICATION SECTION 087100 FOR ACCESS CONTROLS INFORMATION. BUILDING SECURITY TO BE PROVIDED BY OTHERS.KEYNOTE LEGENDKey Value Keynote Text1 PROVIDE 3" DIAMETER BLACK STAINLESS STEEL PIPE WRAPPED IN 2" DURABACK INSULATION FOR GENERATOREXHAUST. COORDINATE ROUTING THROUGH CHASE WITH FRAMING. PROVIDE HILTI C-BJ-7005 WHERE IT PENETRATESRATED CEILING ABOVE GARAGE. PROVIDE THIMBLE WHERE PIPE PENETRATES ROOF.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1 /1E411/1E415/1E411/1E412/1E414/1E411/1E412/1E413EZM3CORNEREZM3EXT800A TERMINAL BLOCK5-METER STACK (TYP OF 6)4-METER STACK (TYP OF 1)DATA DISTRIBUTIONAPPROXIMATE ROUTING OF GENERATOR EXHAUST THROUGH CHASE, EXTENDING TO ROOF1ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION3/32" = 1'-0"3RD FLOOR POWER &DATAE103Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT3/32" = 1'-0"1THIRD FLOOR - POWER & DATAE103 GENERAL NOTES1. REFER TO DRAWING E401, E403 & SPECIFICATION SECTION 087100 FOR ACCESS CONTROLS INFORMATION. BUILDING SECURITY TO BE PROVIDED BY OTHERS.KEYNOTE LEGENDKey Value Keynote Text1 PROVIDE 3" DIAMETER BLACK STAINLESS STEEL PIPE WRAPPED IN 2" DURABACK INSULATION FOR GENERATOREXHAUST. COORDINATE ROUTING THROUGH CHASE WITH FRAMING. PROVIDE HILTI C-BJ-7005 WHERE IT PENETRATESRATED CEILING ABOVE GARAGE. PROVIDE THIMBLE WHERE PIPE PENETRATES ROOF.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1 /1E416/1E420/1E416/1E417/1E419/1E416/1E417/1E418HP-4EZM3CORNEREZM3EXT800A TERMINAL BLOCK5-METER STACK (TYP OF 5)3-METER STACK (TYP OF 1)DATA DISTRIBUTION4-METER STACK (TYP OF 1)APPROXIMATE ROUTING OF GENERATOR EXHAUST THROUGH CHASE, EXTENDING TO ROOF1ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION3/32" = 1'-0"4TH FLOOR POWER &DATAE104Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT3/32" = 1'-0"1FOURTH FLOOR - POWER & DATAE104 GENERAL NOTES1. REFER TO DRAWING E401, E403 & SPECIFICATION SECTION 087100 FOR ACCESS CONTROLS INFORMATION. BUILDING SECURITY TO BE PROVIDED BY OTHERS.KEYNOTE LEGENDKey Value Keynote Text1 PROVIDE 3" DIAMETER BLACK STAINLESS STEEL PIPE WRAPPED IN 2" DURABACK INSULATION FOR GENERATOREXHAUST. COORDINATE ROUTING THROUGH CHASE WITH FRAMING. PROVIDE HILTI C-BJ-7005 WHERE IT PENETRATESRATED CEILING ABOVE GARAGE. PROVIDE THIMBLE WHERE PIPE PENETRATES ROOF.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1 AC/1E421/1E425/1E421/1E422/1E424/1E421/1E422/1E423EZM3CORNEREZM3EXT800A TERMINAL BLOCK5-METER STACK (TYP OF 5)DATA DISTRIBUTION4-METER STACK (TYP OF 1)APPROXIMATE ROUTING OF GENERATOR EXHAUST THROUGH CHASE, EXTENDING TO ROOF1ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION3/32" = 1'-0"5TH FLOOR POWER &DATAE105Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT3/32" = 1'-0"1FIFTH FLOOR - POWER & DATAE105 GENERAL NOTES1. REFER TO DRAWING E401, E403 & SPECIFICATION SECTION 087100 FOR ACCESS CONTROLS INFORMATION. BUILDING SECURITY TO BE PROVIDED BY OTHERS.KEYNOTE LEGENDKey Value Keynote Text1 PROVIDE 3" DIAMETER BLACK STAINLESS STEEL PIPE WRAPPED IN 2" DURABACK INSULATION FOR GENERATOREXHAUST. COORDINATE ROUTING THROUGH CHASE WITH FRAMING. PROVIDE HILTI C-BJ-7005 WHERE IT PENETRATESRATED CEILING ABOVE GARAGE. PROVIDE THIMBLE WHERE PIPE PENETRATES ROOF.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1 GWGWGWGWGWGWGWGWGWGWGWGSPSPSPHFJHP-3APT 229HP-3APT 429HP-3APT 329HP-3APT 228HP-3APT 328HP-3APT 428HP-3APT 330HP-1APT 530HP-3APT 331HP-3APT 531HP-1APT 332HP-1APT 532HP-1APT 333HP-1APT 533HP-3APT 230HP-3APT 430HP-3APT 231HP-3APT 431HP-1APT 232HP-1APT 432HP-1APT 233HP-1APT 433HP-3APT 327HP-3APT 227HP-3APT 427HP-2APT 226HP-2APT 426HP-3APT 527HP-2APT 326HP-2APT 334HP-2APT 534HP-2APT 434HP-2APT 234HP-1APT 225HP-1APT 325HP-1APT 224HP-1APT 324HP-1APT 223HP-1APT 323HP-1APT 222HP-1APT 322HP-3APT 221HP-5FITNESS + YOGAHP-3APT 321HP-2APT 522HP-1APT 523HP-1APT 424HP-1APT 524HP-1APT 425HP-1APT 525HP-3APT 518HP-3APT 318HP-2APT 219HP-3APT 220HP-3APT 320HP-2APT 319HP-3APT 218HP-3APT 418HP-6COMM TENANT 6HP-2APT 401HP-2APT 201HP-2APT 301HP-2APT 501HP-7LOBBYHP-1APT 217HP-1APT 417HP-1APT 216HP-1APT 416HP-1APT 215HP-1APT 415HP-1APT 214HP-1APT 414HP-1APT 213HP-1APT 413HP-1APT 212HP-1APT 317HP-1APT 517HP-1APT 316HP-1APT 516HP-1APT 315HP-1APT 515HP-1APT 314HP-1APT 514HP-1APT 313HP-1APT 513HP-1APT 312HP-1APT 512HP-1APT 412HP-1APT 211HP-1APT 411HP-4TRASH ROOMHP-1APT 511HP-1APT 311HP-4BIKE ROOMHP-3APT 210HP-3APT 410HP-3APT 510HP-3APT 310HP-1APT 202HP-1APT 402HP-1APT 203HP-1APT 403HP-1APT 204HP-1APT 404HP-1APT 205HP-1APT 405HP-1APT 505HP-1APT 305HP-1APT 504HP-1APT 304HP-1APT 503HP-1APT 303HP-1APT 502HP-1APT 302HP-3APT 306HP-3APT 506HP-2APT 209HP-2APT 409HP-2APT 509HP-2APT 309HP-3APT 207HP-3APT 407HP-3APT 507HP-3APT 307HP-3APT 208HP-3APT 408HP-3APT 508HP-3APT 308ERV-4ERV-3ERV-2HP-2APT 422HP-1APT 423HP-3APT 406HP-3APT 206WH-1HWT-1 HWT-1 HWT-1ET-1ERV-1P-ROOFP-DHWHP-8ELEVATORHP-8ELEVATOREF-1EF-2P-ROOF2,4,6P-ROOF1,3,5P-ROOF8,10,12P-ROOF7,9,11P-ROOF14,16,18P-ROOF13P-ROOF15,17P-ROOF20,22FC-8FC-8P-ROOF24,26P-GEN31HPWH-1HPWH-1HPWH-1HPWH-1HPWH-1HPWH-1HPWH-1HPWH-12P-ROOF23P-ROOF23P-ROOF23P-ROOF23P-ROOF23P-ROOF23P-ROOF28P-ROOF28P-ROOF28P-ROOF28P-ROOF28P22917,19P22819,21P22716,18P23016,18P53016,18P23119,21P23216,18P23219,21P23315,17P23416,18P22314,16P22214,16P22117,19P42218,20P22019,21P21916,18P21817,19P20117,19P21217,19P21116,18P21010,12P20316,18P20517,19P20916,18P20719,21P20818,20P21318,2033HP-3APT 420HP-3APT 520P42020,22MV-1P-1P-2AP-2B4ZV-1ZV-2ZV-156P-GEN15,17,19P-GEN1678P-ROOF19,2178MHP47,49,51MHP48P-ROOF30,32P-GEN18,20910HPWH-1ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION3/32" = 1'-0"ROOF ELECTRICALPLANE106Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT3/32" = 1'-0"1ROOF - ELECTRICALKEYNOTE LEGENDKey Value Keynote Text1 PROVIDE 3" DIAMETER BLACK STAINLESS STEEL PIPE WRAPPED IN 2" DURABACK INSULATION FOR GENERATOREXHAUST. COORDINATE ROUTING THROUGH CHASE WITH FRAMING. PROVIDE HILTI C-BJ-7005 WHERE IT PENETRATESRATED CEILING ABOVE GARAGE. PROVIDE THIMBLE WHERE PIPE PENETRATES ROOF.2 REFER TO P-DHW PANEL SCHEDULE FOR NUMBER OF ELECTRICAL CONNECTIONS TO SANDEN UNITS. REFER TOPLUMBING DRAWINGS FOR ARRANGEMENT OF OUTDOOR UNITS. PROVIDE EACH UNIT WITH 30 AMP, 208V SINGLEPHASE, NEMA 3R ENCLOSURE, DISCONNECT SWITCH. DISCONNECT SWITCH NOT SHOWN FOR CLARITY.3 FAN COIL IS POWERED DIRECTLY FROM OUTDOOR CONDENSING UNIT. WIRING BY MECHANICAL CONTRACTOR.4 ELECTRIC BOILER, REFER TO P-ROOF PANEL SCHEDULE FOR SIZING. PROVIDE 3-#350 KCMIL AL., 1-#2 AL. G, 3"CONDUIT.5 PROVIDE TRANSFORMER FOR 24V CONNECTION TO ZONE VALVES. COORDINATE WITH PLUMBING CONTRACTOR.6 REFER TO P-DHW PANEL SCHEDULE FOR CIRCUITING TO PLUMBING COMPONENTS.7 PROVIDE NON-FUSED AUXILIARY ELEVATOR DISCONNECT AT TOP OF ELEVATOR HOISTWAY. REFER TO ELEVATORINSTALLATION DOCUMENTATION FOR REQUIREMENTS. COORDINATE WITH ELEVATOR EQUIPMENT INSTALLATION.8 PROVIDE DISCONNECT FOR ELEVATOR CAR LIGHTING CIRCUIT. COORDINATE NSTALLATION REQUIREMENTS WITHELEVATOR CONTRACTOR.9 PROVIDE HEAT DETECTOR (FIXED TEMPERATURE) NEAR SPRINKLER HEADS IN ELEVATOR SHAFT, WHERE THEY OCCUR.10 PROVIDE CONNECTION TO HEAT TRACE ON SANDEN UNIT OUTDOOR PIPING. COORDINATE WITH PLUMBINGCONTRACTOR.E106 GENERAL NOTES1. PROVIDE ELECTRICAL RECEPTICAL WITHIN 25' OF ALL HVAC EQUIPMENT ON ROOF, PER NEC 210.63.2. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.3. APARTMENT CONDENSING UNITS ARE ONLY CIRCUITED FOR TYPICAL APARTMENTS. REFER TO PANEL SCHEDULES FOR TYPICAL CIRCUITING FOR CONDENSING UNITS TO ALL APARTMENTS. 12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1 /1E401_R/1E405_R/1E401_R/1E402_R/1E404_R/1E401_R/1E402_R/1E403_RRAFACPBICYCLEROOM115RESTROOM113PET SPA110YOGASTUDIO109PET RELIEFAREA111ELECTRICROOM122PACKAGEROOM102RESIDENTLOUNGE107COMMERCIALTENANTSPACE119TRASHROOM116CENTRALSTAIRELEV 1ELEV 2TELECOMROOM118UTILITYCORRIDOR117EXITCORRIDOR125PARKING126EXITCORRIDOR114VESTIBULE100RESTROOM112MAIL ROOM103ELEVATORLOBBY106LOBBY101EAST STAIR123STORAGE130FITNESSCENTER108LEASINGOFFICE104WATERSERVICEROOM105STORAGE123BSTORAGE124BNORTHSTAIRERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION3/32" = 1'-0"1ST FLOOR LIGHTING &FAE201Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT3/32" = 1'-0"1FIRST FLOOR - LIGHTING & FIRE ALARM12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET /1E406_R/1E410_R/1E406_R/1E407_R/1E409_R/1E406_R/1E407_R/1E408_RERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION3/32" = 1'-0"2ND FLOOR LIGHTING& FAE202Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT3/32" = 1'-0"1SECOND FLOOR - LIGHTING & FIRE ALARM12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET /1E411_R/1E415_R/1E411_R/1E412_R/1E414_R/1E411_R/1E412_R/1E413_RERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION3/32" = 1'-0"3RD FLOOR LIGHTING &FAE203Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT3/32" = 1'-0"1THIRD FLOOR - LIGHTING & FIRE ALARM12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET /1E416_R/1E420_R/1E416_R/1E417_R/1E419_R/1E416_R/1E417_R/1E418_RERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION3/32" = 1'-0"4TH FLOOR LIGHTING &FAE204Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT3/32" = 1'-0"1FOURTH FLOOR - LIGHTING & FIRE ALARM12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET /1E421_R/1E425_R/1E421_R/1E422_R/1E424_R/1E421_R/1E422_R/1E423_RERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION3/32" = 1'-0"5TH FLOOR LIGHTING &FAE205Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT3/32" = 1'-0"1FIFTH FLOOR - LIGHTING & FIRE ALARM12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET GWGGP DOJJJJJJCR CRAC4ACTRASHROOM116ELECTRICROOM122BICYCLEROOM115ELEV 1ELEV 2ERV-61122EBH-34000A 208Y/120V MAIN SERVICE DISCONNECTFEEDER SECTION -APARTMENT METER SECTIONS & COMMERCIAL METERS (SERVICE DISCONNECTS 1-5)HOUSE METER & CT CABINET SECTION (SERVICE DISCONNECT 6)CENTRALSTAIRELEVATORLOBBY106/1E403/1E405/1E404/1E40233G-ATSP-GENMHPHP-1HP-133HP-134HP-132HP-135HP-136HP-138NORTHSTAIRHP-128HP-123HP-16SP-1SP-1ERV-8FC-4FC-4EWH-1MHP13,15MHP21,23MHP22,24,26MHP25REFER TO E101 FOR GENERATORREFER TO E101-E106 FOR GENERATOR EXHAUST ROUTINGHP-140HP-139,41COMMERCIAL FEEDER DISTRIBUTIONEDH-2EDH-2FACPMHP28EWH-1MHP30MHP35,37MHP40,42MHP17,19MHP17,194HP-150MHP47,49,51P-GEN15,17,195P-GEN21666666MHP4MHP678119101191111HP-13012111HP-130MHP9131ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"1ST FL CORE ENLRGDPLAN -PWR & DATAE401Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIRST FLOOR CORE ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 PROVIDE CONVENIENCE RECEPTACLE IN ELEVATOR PIT FOR ELEVATOR SERVICING, PER NEC 620.24(C).2 PROVIDE GFCI BREAKER FOR SUMP PUMP RECEPTACLE CIRCUIT. COORDINATE RECEPTACLE LOCATION WITH PLUMBING CONTRACTORAND SUMP PUMP INSTALLATION.3 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.4 COORDINATE ALL DOOR OPERATOR BUTTONS WITH ARCHITECT AND BUILDING OWNER. ELECTRICAL CONTRACTOR TO PROVIDE ALLPATHWAYS AND WIRING BETWEEN DOOR OPERATOR AND ASSOCIATED HARDWARE.5 PROVIDE FUSED SHUNT-TRIP ELEVATOR DISCONNECT SWITCH. SWITCH SHALL BE BUSSMANN SERIES QUICK-SPEC POWER MODULESWITCH (MODEL #PS6-T20-R2-K-G-N6-B-F1-U WITH 45A CLASS J FUSES). COORDINATE SHUNT-TRIP CONTROL WIRING WITH FIRE ALARMSYSTEM INSTALLER. COORDINATE ELEVATOR CONTROL WIRING TO DISCONNECT SWITCH'S AUXILIARY CONTACTS WITH ELEVATORINSTALLER.6 PROVIDE CONNECTION TO HEAT TRACE TO DVW AND PRIMARY STORM RISERS IN GARAGE. COORDINATE WITH PLUMBING CONTRACTOR.7 REFER TO CIVIL DRAWINGS FOR CONDUIT PATHING FOR MAIN SERVICE AND TELECOMMUNICATIONS.8 PROVIDE 60A, 208V, 3 PHASE, FUSED DISCONNECT, NEMA 4 RATED ENCLOSURE TO SERVE TRASH COMPACTOR. PROVIDE FUSESACCORDING TO TRASH COMPACTOR RECOMMENDATIONS.9 PROVIDE STANDARD CARD READER, REFER TO ACCESS CONTROL, SPECIFICATION SECTION 087100, PROVIDE DATA CONNECTION ANDCABLING BACK TO ACCESS CONTROLS AND ETHERNET SWITCH. COORDINATE ACCESS CONTROL PANEL WITH ARCHITECTURALDRAWINGS.10 PROVIDE ALL INTERCONNECTION BETWEEN ACCESS CONTROL SYSTEM, CARD READER, DOOR LOCKING HARDWARE AND ADA DOORCONTROLS ACCORDING TO MANUFACTURERS RECOMMENDATIONS .11 PROVIDE DATA CABLING FOR CONNECTION TO WIFI ABOVE CEILING. PROVIDE EXTRA 15' CABLE COILED UP ABOVE CEILING, PROVIDEDUPLEX RECEPTACLE MOUNTED TO STRUCTURE ABOVE CEILING AND CIRCUITING AS SHOWN.12 PROVIDE REMOTE BUTTERFLYMX RELAY, DATA CABLING AND CONNECTION FOR ELEVATOR LOCK SYSTEM FROM BUTTERFLYMX PANELVIA ACCESS CONTROLS. INSTALL WIRING ACCORDING TO MANUFACTURERS RECOMMENDATION.13 PROVIDE FIBEROPTIC BACKBONE FOR 10GB ETHERNET SWITCH.E401 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. ALL OUTLET LOCATIONS IN AMMENITY SPACES TO BE COORDINATED WITH INTERIOR DESIGN SHEETS.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11 3KPKP334SPSPSPSPSPSPTTKPOSVSSPSPTRASHROOM116/1E405_R/1E402_R/1E404_R/1E403_RELEV 2ELEV 11111112AL2AD2TTTTTTTTEMS1 S1S1S1S1EX1EX2S1S1EMEX3EMS1RRREX3EX3EX3RRHP-1PPACL1ELECTRICROOM122CENTRALSTAIREMAD2TSFS3NORTHSTAIRP-GEN1E4E5AD2HP-144HP-146HP-147S2STORAGE124BMHP44AD2AD2EMZONE 5ZONE 9ZONE 354EM5TTTEMEMHP-143P-GEN4RP-GEN3P-GEN4EMP-GEN4ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"1ST FLR CORE ENLRGDPLAN -LTG & FAE401_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIRST FLOOR CORE ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.2 PROVIDE SMOKE DETECTORS WITH AUXILIARY CONTACTS AT ALL ELEVATOR LANDINGS. MAKE AUXILIARY CONNECTION BETWEENDETECTORS AND LDU PANELS AS REQUIRED BY ELEVATOR MANUFACTURER. COORDINATE WITH ELEVATOR EQUIPMENT INSTALLATION.3 PROVIDE FIRE ALARM CONNECTION TO SPRINKLER SYSTEM TAMPER AND FLOW SWITCHES. COORDINATE WITH SPRINKLERCONTRACTOR.4 FIXTURES IN TRASH ROOM SHALL BE SUSPENDED AT 7'-6" AFF. COORDINATE LOCATIONS AND MOUNTING HEIGHTS WITH MECHANICALEQUIPMENT.5 AT INDICATED LOCATIONS, PROVIDE DUAL OUTPUT OCCUPANCY SENSOR (BOD: CRESTRON GLA-DT-QUATTRO-COM2-24) TO PROVIDECONTROL OF EXHAUST. COORDINATE WIRING WITH MECHANICAL CONTRACTOR.E401_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSOR TO CONTROL ALL HALL OR ROOM LIGHTING. OCCUPANCY"ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. REFER TO INTERIOR DESIGN REFLECTED CEILING PLANS FOR DIMENSIONEDLOCATIONS OF LIGHT FIXTURES IN AMENTIY SPACES. COORDINATE ALL DEVICE LOCATIONS WITH INTERIOR DESIGN REFLECTED CEILING PLANS AND ELEVATIONS.5. WHERE LIGHTING IS INDICATED WITH ZONE, REFER TO LIGHTING CONTROLLER ZONING DIAGRAM ON E001. FIXTURES ARE TO BE CONTROLLED BY CENTRALIZED LIGHTING CONTROLLER.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1 AAMJJJJJJJJJEBH-1/1E403/1E4011EAST STAIR123HP-137EXITCORRIDOR1252TELECOMROOM118UTILITYCORRIDOR117STORAGE130EBH-3EBH-3CP1 CP2 CP3CT CABINETSCP11,3CP118HP-140HP-139,41EWH-1MHP29MHP50333333333MHP8MHP64HP-114"x4" JUNCTION / PULLBOX REFER TO DWG E1014"x4" JUNCTION / PULLBOX REFER TO DWG E10151ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"1ST FL EAST ENLRGDPLAN -PWR & DATAE402Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIRST FLOOR EAST ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.2 PROVIDE 3/4" PAINTED PLYWOOD BACK BOARD FOR TELECOM SERVICE HEAD END EQUIPMENT. ALL BACKBONE CABLING TO DATA RACKSIN TELECOM ROOMS SHALL BE BROUGHT BACK TO THIS LOCATION.3 PROVIDE CONNECTION TO HEAT TRACE TO DVW AND PRIMARY STORM RISERS IN GARAGE. COORDINATE WITH PLUMBING CONTRACTOR.4 REFER TO CIVIL DRAWINGS FOR CONDUIT PATHING FOR MAIN SERVICE AND TELECOMMUNICATIONS.5 PROVIDE FIBEROPTIC BACKBONE FOR 10GB ETHERNET SWITCH.E402 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. ALL OUTLET LOCATIONS IN AMMENITY SPACES TO BE COORDINATED WITH INTERIOR DESIGN SHEETS.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111 4SPSPSPSPSPSPSPSPSPVSVS/1E401_R/1E403_R111TTTTTTTTTTTTEMEMEMS1S1S1EMS1S1EX3RRRS1RRREX3EXITCORRIDOR125EAST STAIR123STORAGE123BSTORAGE130P-GEN2RS1TELECOMROOM118UTILITYCORRIDOR117P-GEN5MHP44EMS2MHP44P-GEN4TTTTTEMEMP-GEN4HP-143P-GEN4ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"1ST FL EAST ENLRGDPLAN -LTG & FAE402_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIRST FLOOR EAST ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.E402_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSOR TO CONTROL ALL HALL OR ROOM LIGHTING. OCCUPANCY"ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. REFER TO INTERIOR DESIGN REFLECTED CEILING PLANS FOR DIMENSIONEDLOCATIONS OF LIGHT FIXTURES IN AMENTIY SPACES. COORDINATE ALL DEVICE LOCATIONS WITH INTERIOR DESIGN REFLECTED CEILING PLANS AND ELEVATIONS.5. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1 GGGAAAAGWGWGWDODOPPCRCRCRCRCRTV4ELEV 1ELEV 2FC-7FC-9RA12233EBH-1EBH-1EBH-3/1E402/1E401/1E404COMMERCIALTENANTSPACE119CENTRALSTAIR4ECPVESTIBULE100LOBBY101WATERSERVICEROOM105LEASINGOFFICE104HP-123HP-128HP-133HP-134HP-132HP-135HP-1365HP-124TELECOMROOM1186SP-1SP-1UTILITYCORRIDOR117FC-4MHP17,19MHP17,197EBH-2EBH-3EBH-3EBH-3EBH-3EBH-3EBH-3EBH-3EBH-3CP1 CP2 CP3CT CABINETSCP11,3CP12,4CP15,7CP16,8CP19,11CP110,12CP113,15CP114,16CP117,19CP118CP120HP-140HP-140HP-139,41HP-139,41HP-142EDH-4MHP39,4188MHP18,20MHP50HP-150910HP-13P-GEN2411121311114141411114115HP-1301615171HP-1611181ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"1ST FL SOUTH ENLRGDPLAN -PWR & DATAE403Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIRST FLOOR SOUTH ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 CONFIRM RECESSED LOCATIONS AND FINISHES OF ALL EQUIPMENT/DEVICES ON THIS WALL W/ID&ARCH, PRIOR TO INSTALLATION. NOTE48" IS MAX HEIGHT TO ANY OPERABLE PARTS/CONTROLS.2 PROVIDE CONVENIENCE RECEPTACLE IN ELEVATOR PIT FOR ELEVATOR SERVICING, PER NEC 620.24(C).3 PROVIDE GFCI BREAKER FOR SUMP PUMP RECEPTACLE CIRCUIT. COORDINATE RECEPTACLE LOCATION WITH PLUMBING CONTRACTORAND SUMP PUMP INSTALLATION.4 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.5 PROVIDE 3/4" PAINTED PLYWOOD BACK BOARD FOR TELECOM SERVICE HEAD END EQUIPMENT. ALL BACKBONE CABLING TO DATA RACKSIN TELECOM ROOMS SHALL BE BROUGHT BACK TO THIS LOCATION.6 PROVIDE DISCONNECT, WIRING, AND CONNECTION TO COMPRESSOR FOR DRY SPRINKLER SYSTEM. COORDINATE ELECTRICALREQUIREMENTS AND LOCATION WITH SPRINKLER CONTRACTOR.7 PROVIDE EMERGENCY COMMUNICATIONS SYSTEM TO ALLOW COMMUNICATION BETWEEN EMERGENCY COMMUNICATIONS PANEL (ECP)LOCATED ADJACENT TO FIRE ALARM PANEL IN LOBBY, AND EMERGENCY CALL STATIONS AND SIGNS (EC) LOCATED ADJACENT TOELEVATOR CALL BUTTONS ON ALL FLOORS. SYSTEM SHALL BE AS MANUFACTURED BY RATH COMMUNICATIONS AREA OF REFUGESYSTEMS. SYSTEM SHALL CONSIST OF MAIN PANEL #2500-205FM (PAINTED BLACK), CALL BOX #2100-958NSR, POWER SUPPLY#2500-PWR24, SIGN#7078, AND ALL MISCELLANEOUS HARDWARE AND WIRING TO MAKE A COMPLETE SYSTEM.8 COORDINATE ALL DOOR OPERATOR BUTTONS WITH ARCHITECT AND BUILDING OWNER. ELECTRICAL CONTRACTOR TO PROVIDE ALLPATHWAYS AND WIRING BETWEEN DOOR OPERATOR AND ASSOCIATED HARDWARE.9 REFER TO CIVIL DRAWINGS FOR CONDUIT PATHING FOR MAIN SERVICE AND TELECOMMUNICATIONS.10 PROVIDE CRESTRON LIGHTING CONTROLLER. SYSTEM SHALL BE COMPRISED OF GLCAEN-FT-120-LV8-LV8-LV8-DIMU8-DIMU8 SYSTEM,GLS-SIM INTEGRATION MODULES, GLNET-CN CONTROL PROCESSOR, KEY PADS, TSW-770-W-S TOUCH SCREEN, AND OCCUPANCYSENSORS AS SHOWN ON DRAWINGS. CONTROLLER SHALL PROVIDE COVERAGE OF ALL AREAS OF FIRST FLOOR, WITH THE EXCEPTIONOF BATHROOMS, COMMERCIAL TENANT SPACE, PARKING, WATER SERVICE ROOM, AND UTILITY SPACES.11 PROVIDE APC UPS, 600VA UPS BATTERY BACK-UP & SURGE PROTECTION, BE600M1 BATTERY POWER SUPPLY OR EQUAL, COORDINATEEXACT LOCATION WITH OWNER PRIOR TO INSTALLATION.12 PROVIDE TOUCH SCREEN / INTERCOM SYSTEM, BUTTERFLYMX, 11.6" RECESSED INTERCOM, CARD READER, 24VDC, OR APPROVEDEQUAL. PROVIDE DATA CONNECTION TO ACCESS CONTROL SYSTEM AND ETHERNET SWITCH ACCORDING TO MANUFACTURERSRECOMMENDATION. PROVIDE REMOTE BUTTERFLYMX RELAY FOR DOOR STRIKE RELEASE CONTROL.13 PROVIDE ALL INTERCONNECTION BETWEEN ACCESS CONTROL SYSTEM, CARD READER, DOOR LOCKING HARDWARE AND ADA DOORCONTROLS ACCORDING TO MANUFACTURERS RECOMMENDATIONS .14 PROVIDE STANDARD CARD READER, REFER TO ACCESS CONTROL, SPECIFICATION SECTION 087100, PROVIDE DATA CONNECTION ANDCABLING BACK TO ACCESS CONTROLS AND ETHERNET SWITCH. COORDINATE ACCESS CONTROL PANEL WITH ARCHITECTURALDRAWINGS.15 COORDINATE MOUNTING HEIGHT OF DATA JACK FOR TV WITH OWNER.16 PROVIDE REMOTE BUTTERFLYMX RELAY, DATA CABLING AND CONNECTION FOR ELEVATOR LOCK SYSTEM FROM BUTTERFLYMX PANELVIA ACCESS CONTROLS. INSTALL WIRING ACCORDING TO MANUFACTURERS RECOMMENDATION.17 COORDINATE MOUNTING HEIGHT OF POWER & CABLE RECEPTACLES FOR TV WITH OWNER.18 PROVIDE FIBEROPTIC BACKBONE FOR 10GB ETHERNET SWITCH.E403 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. ALL OUTLET LOCATIONS IN AMMENITY SPACES TO BE COORDINATED WITH INTERIOR DESIGN SHEETS.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11 3334SPSPSPSPSPSPSPSPSPSPSPSPSPSPSPTKPJRA1TSFS/1E402_R/1E404_RELEV 2ELEV 1/1E401_R2223WATERSERVICEROOM105AD2AD24AD2AD2AD2AD2AD2EMEMEMEMEMEX1S1S1EX2S1S1S1S1S1S1S1S1S1S1EMEMEMEMEX3EX3EX3EX3EMEMS1S1S1RRPAP4BAP4AAP4CACL1COMMERCIALTENANTSPACE119LEASINGOFFICE104AF1AF1AF1CENTRALSTAIRTSFS4E1E1E1E1E1E1AD2HP-144HP-1475UTILITYCORRIDOR117CP121EMHP-1496ACL2AD2AD2E3E3E3E3ZONE 9ZONE 10ZONE 11ZONE 31ZONE 36ZONE 36HP-1487RP-GEN3ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"1ST FL SOUTH ENLRGDPLAN -LTG & FAE403_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIRST FLOOR SOUTH ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 PROVIDE WEATHERPROOF HORN-STROBE ON BUILDING EXTERIOR. COORDINATE LOCATION WITH LOCAL FIRE DEPARTMENTREQUIREMENTS.2 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.3 PROVIDE SMOKE DETECTORS WITH AUXILIARY CONTACTS AT ALL ELEVATOR LANDINGS. MAKE AUXILIARY CONNECTION BETWEENDETECTORS AND LDU PANELS AS REQUIRED BY ELEVATOR MANUFACTURER. COORDINATE WITH ELEVATOR EQUIPMENT INSTALLATION.4 PROVIDE FIRE ALARM CONNECTION TO SPRINKLER SYSTEM TAMPER AND FLOW SWITCHES. COORDINATE WITH SPRINKLERCONTRACTOR.5 PROVIDE CRESTRON LIGHTING CONTROLLER. SYSTEM SHALL BE COMPRISED OF GLCAEN-FT-120-LV8-LV8-LV8-DIMU8-DIMU8 SYSTEM,GLS-SIM INTEGRATION MODULES, GLNET-CN CONTROL PROCESSOR, KEY PADS, TSW-770-W-S TOUCH SCREEN, AND OCCUPANCYSENSORS AS SHOWN ON DRAWINGS. CONTROLLER SHALL PROVIDE COVERAGE OF ALL AREAS OF FIRST FLOOR, WITH THE EXCEPTIONOF BATHROOMS, COMMERCIAL TENANT SPACE, PARKING, WATER SERVICE ROOM, AND UTILITY SPACES.6 PROVIDE CONNECTION TO BUILDING SIGNAGE ILLUMINATION ON SOUTHERN EXTERIOR AND CANOPY. REFER TO ARCHITECTURALDRAWINGS FOR DETAILS. COORDINATE ELECTRICAL CONNECTION TYPE AND LOAD WITH SUBMITTED PRODUCT. PROVIDE ELECTRONICTIMER TO CONTROL OPERATION.7 AT INDICATED LOCATIONS, PROVIDE DUAL OUTPUT OCCUPANCY SENSOR (BOD: CRESTRON GLA-DT-QUATTRO-COM2-24) TO PROVIDECONTROL OF EXHAUST. COORDINATE WIRING WITH MECHANICAL CONTRACTOR.E403_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSOR TO CONTROL ALL HALL OR ROOM LIGHTING. OCCUPANCY"ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. REFER TO INTERIOR DESIGN REFLECTED CEILING PLANS FOR DIMENSIONEDLOCATIONS OF LIGHT FIXTURES IN AMENTIY SPACES. COORDINATE ALL DEVICE LOCATIONS WITH INTERIOR DESIGN REFLECTED CEILING PLANS AND ELEVATIONS.5. WHERE LIGHTING IS INDICATED WITH ZONE, REFER TO LIGHTING CONTROLLER ZONING DIAGRAM ON E001. FIXTURES ARE TO BE CONTROLLED BY CENTRALIZED LIGHTING CONTROLLER.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET GWGWGAGWGAGAAAGAGAJJGJJJGGATVAATV TVGGGGWGWGWGAGWGGGAAJJP DOADODOPPSSCR CR1CRCR1 1 11AC 11111ACACTV4ACTRASHROOM116BICYCLEROOM115ELEV 1ELEV 2PACKAGEROOM102RESIDENTLOUNGE107YOGASTUDIO109PET RELIEFAREA111PET SPA110RESTROOM112RESTROOM113ERV-7ERV-6FC-7FC-6FC-5ERV-5FC-91122334556RA755558899EBH-1/1E401CENTRALSTAIRELEVATORLOBBY106/1E40310ECPVESTIBULE100LOBBY101MAIL ROOM103FITNESSCENTER108WATERSERVICEROOM105LEASINGOFFICE104P-GYMHP-1P-GYM14P-GYM12P-GYM11P-GYM10P-GYM9P-GYM8P-GYM7P-GYM6P-GYM5P-GYM4P-GYM3P-GYM2P-GYM1HP-126HP-123HP-125P-GYM13HP-123HP-128HP-19HP-14HP-17HP-121HP-110HP-112HP-122HP-113HP-120HP-112HP-115,17HP-114HP-116,18HP-119HP-133HP-134HP-132HP-135HP-136HP-128HP-123HP-16HP-124HP-12711SP-1SP-1P-GYM141212HP-110MHP1HP-12HP-123HP-129HP-15HP-181313ERV-8FC-4FC-4MHP10,12MHP13,15MHP14,161414MHP17,19MHP17,19MHP21,23MHP22,24,26MHP25HP-161512" AFF12" AFFHP-110HP-111HP-111HP-131EDH-1HP-142EDH-2EDH-2EDH-2EDH-4EDH-3EDH-4MHP31,33MHP32,34MHP35,37MHP36,38MHP39,41MHP40,42MHP43,45MHP17,19MHP17,19161616HP-150MHP18,20HP-150171811HP-1311P-GEN24192021222111111222212324242525HP-130HP-13026111111111251231231HP-130HP-130HP-130272551HP-1611231HP-130ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"1ST FL WEST ENLRGDPLAN -PWR & DATAE404Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIRST FLOOR WEST ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 PROVIDE GFI CIRCUIT FOR BOTTLE FILLER. COORDINATE LOCATION OF J-BOX FOR HARDWIRE CONNECTIONWITH PLUMBING CONTRACTOR. PROVIDE HARDWIRE CONNECTION TO REMOTE CHILLER. COORDINATECONNECTION WITH PLUMBING CONTRACTOR.2 CONTRACTOR SHALL FURNISH AND INSTALL UNDER-SINK RECEPTACLE FOR CORD CONNECTED GARBAGEDISPOSAL/DISHWASHER. SWITCH LOCATED ABOVE COUNTER SHALL CONTROL LOWER PORTION OFRECEPTACLE.3 PROVIDE SEPARATE HARDWIRE CONNECTIONS TO BUILT-IN STOVE AND OVEN. COORDINATE J-BOX LOCATIONAND CIRCUIT PATHING WITH CABINETRY INSTALLATION.4 PROVIDE HARDWIRE ELECTRICAL CONNECTION TO VENTHOOD. COORDINATE WITH HOOD INSTALLATION.5 COORDINATE MOUNTING HEIGHT OF POWER & CABLE RECEPTACLES FOR TV WITH OWNER.6 CONFIRM FINAL LOCATION OF OUTLETS BEHIND COFFEE STATION W/ ID & OWNER.7 CONFIRM RECESSED LOCATIONS AND FINISHES OF ALL EQUIPMENT/DEVICES ON THIS WALL W/ID&ARCH,PRIOR TO INSTALLATION. NOTE 48" IS MAX HEIGHT TO ANY OPERABLE PARTS/CONTROLS.8 PROVIDE CONVENIENCE RECEPTACLE IN ELEVATOR PIT FOR ELEVATOR SERVICING, PER NEC 620.24(C).9 PROVIDE GFCI BREAKER FOR SUMP PUMP RECEPTACLE CIRCUIT. COORDINATE RECEPTACLE LOCATION WITHPLUMBING CONTRACTOR AND SUMP PUMP INSTALLATION.10 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACHSTAIRWELL. REFER TO PANEL SCHEDULES.11 PROVIDE DISCONNECT, WIRING, AND CONNECTION TO COMPRESSOR FOR DRY SPRINKLER SYSTEM.COORDINATE ELECTRICAL REQUIREMENTS AND LOCATION WITH SPRINKLER CONTRACTOR.12 PROVIDE HARDWIRE CONNECTION TO FIREPLACE. PROVIDE MAIN SWITCH AS SHOWN TO CONTROLOPERATION. COORDINATE ROUTING OF CIRCUIT WITH OTHER TRADES.13 REFER TO SHEET ID704 FOR RECEPTACLE MOUNTING IN CABINETRY IN RESIDENT LOUNGE KITCHEN.14 FAN COIL IS POWERED DIRECTLY FROM OUTDOOR CONDENSING UNIT. WIRING BY MECHANICAL CONTRACTOR.15 PROVIDE EMERGENCY COMMUNICATIONS SYSTEM TO ALLOW COMMUNICATION BETWEEN EMERGENCYCOMMUNICATIONS PANEL (ECP) LOCATED ADJACENT TO FIRE ALARM PANEL IN LOBBY, AND EMERGENCY CALLSTATIONS AND SIGNS (EC) LOCATED ADJACENT TO ELEVATOR CALL BUTTONS ON ALL FLOORS. SYSTEMSHALL BE AS MANUFACTURED BY RATH COMMUNICATIONS AREA OF REFUGE SYSTEMS. SYSTEM SHALLCONSIST OF MAIN PANEL #2500-205FM (PAINTED BLACK), CALL BOX #2100-958NSR, POWER SUPPLY#2500-PWR24, SIGN#7078, AND ALL MISCELLANEOUS HARDWARE AND WIRING TO MAKE A COMPLETE SYSTEM.16 COORDINATE ALL DOOR OPERATOR BUTTONS WITH ARCHITECT AND BUILDING OWNER. ELECTRICALCONTRACTOR TO PROVIDE ALL PATHWAYS AND WIRING BETWEEN DOOR OPERATOR AND ASSOCIATEDHARDWARE.17 PROVIDE CRESTRON LIGHTING CONTROLLER. SYSTEM SHALL BE COMPRISED OFGLCAEN-FT-120-LV8-LV8-LV8-DIMU8-DIMU8 SYSTEM, GLS-SIM INTEGRATION MODULES, GLNET-CN CONTROLPROCESSOR, KEY PADS, TSW-770-W-S TOUCH SCREEN, AND OCCUPANCY SENSORS AS SHOWN ON DRAWINGS.CONTROLLER SHALL PROVIDE COVERAGE OF ALL AREAS OF FIRST FLOOR, WITH THE EXCEPTION OFBATHROOMS, COMMERCIAL TENANT SPACE, PARKING, WATER SERVICE ROOM, AND UTILITY SPACES.18 PROVIDE 60A, 208V, 3 PHASE, FUSED DISCONNECT, NEMA 4 RATED ENCLOSURE TO SERVE TRASHCOMPACTOR. PROVIDE FUSES ACCORDING TO TRASH COMPACTOR RECOMMENDATIONS.19 PROVIDE APC UPS, 600VA UPS BATTERY BACK-UP & SURGE PROTECTION, BE600M1 BATTERY POWER SUPPLYOR EQUAL, COORDINATE EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION.20 PROVIDE TOUCH SCREEN / INTERCOM SYSTEM, BUTTERFLYMX, 11.6" RECESSED INTERCOM, CARD READER,24VDC, OR APPROVED EQUAL. PROVIDE DATA CONNECTION TO ACCESS CONTROL SYSTEM AND ETHERNETSWITCH ACCORDING TO MANUFACTURERS RECOMMENDATION. PROVIDE REMOTE BUTTERFLYMX RELAY FORDOOR STRIKE RELEASE CONTROL.21 PROVIDE ALL INTERCONNECTION BETWEEN ACCESS CONTROL SYSTEM, CARD READER, DOOR LOCKINGHARDWARE AND ADA DOOR CONTROLS ACCORDING TO MANUFACTURERS RECOMMENDATIONS .22 PROVIDE STANDARD CARD READER, REFER TO ACCESS CONTROL, SPECIFICATION SECTION 087100, PROVIDEDATA CONNECTION AND CABLING BACK TO ACCESS CONTROLS AND ETHERNET SWITCH. COORDINATEACCESS CONTROL PANEL WITH ARCHITECTURAL DRAWINGS.23 PROVIDE DATA CABLING FOR CONNECTION TO WIFI ABOVE CEILING. PROVIDE EXTRA 15' CABLE COILED UPABOVE CEILING, PROVIDE DUPLEX RECEPTACLE MOUNTED TO STRUCTURE ABOVE CEILING AND CIRCUITINGAS SHOWN.24 TYPICAL, PROVIDE CAT 6 DATA FEMALE TO FEMALE WALL PLATE AND CABLE CONNECTION IN SINGLE GANGDEVICE. ROUTE CAT6 CABLE BACK TO NEAREST ETHERNET SWITCH.25 COORDINATE MOUNTING HEIGHT OF DATA JACK FOR TV WITH OWNER.26 PROVIDE WIRELESS ACCESS POINT DATA JACK AND RECEPTACLE IN UPPER CABINET.27 PROVIDE REMOTE BUTTERFLYMX RELAY, DATA CABLING AND CONNECTION FOR ELEVATOR LOCK SYSTEMFROM BUTTERFLYMX PANEL VIA ACCESS CONTROLS. INSTALL WIRING ACCORDING TO MANUFACTURERSRECOMMENDATION.E404 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. CONTRACTOR SHALL COORDINATE ALL ELECTRICAL RECEPTACLES, LIGHTING, SIGNAGE, AND FIRE ALARM DEVICES WITH ID DRAWINGS PRIOR TO INSTALLATION. REPRESENTATION OF DEVICES ON WALLS ARE SCHEMATIC. FINAL LOCATIONAND MOUNTING HEIGHTS SHALL BE PER ID DRAWINGS. 12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11 OSOSKPKPKPKPKPKP3SPSPSPSPSPSPHRSPSPSPSPSPSPSPSPSPSPSPTTKPKPKPKPKPKPKPKPOSOSJJYOGASTUDIO109PET RELIEFAREA111BICYCLEROOM115TRASHROOM116ELEVATORLOBBY106MAIL ROOM103RA1TSFS/1E401_R/1E403_RELEV 2ELEV 1/1E401_R2223AF2AP2AP2WATERSERVICEROOM105AF2AF2AF2 AF2AF2AF2AF2AF4AF4AF3AF3AF3AF4AF4AF3AF3AF4 AF4AF4AF3AF4AL1AL1AL1AL1AL1AW2AL4AL4AL4AL4AL4AA1 AA1ALP2 ALP2AA1 AA1 AA1AD2AD2AP3AD1AD1AD1AF5 AF5AF5AD2AD24AL4AL2AL2 AL2AL2AL2AD2AD2AD2AD2AD2TEMEMEMEMEMEMEMEMEMEMEMEMS1S1EMEX1EX1EX1S1S1EX1S1 S1S1S1S1EX1EX2S1EX3RRHP-1P-GYM5PPALP1EMEMEMEMCrestron touch screen controllerEMEMEMAP4BAP4AAP4CAP4BAP4AAP4CAD1AD1AD4AD4ACL1AL3AL3AL3AL3AL3AL3AL3RESIDENTLOUNGE107LEASINGOFFICE104FITNESSCENTER108PACKAGEROOM102ACL2ACL2AP1AAP1BAP1AAP1AAP1BAF1AF1AF1CENTRALSTAIRAD2AL5AL5AL5AL5TSFS4AW1AW1AW1AW1E1E1E1E1E1E1E1E1E1AD3AD3AD3AD3AL4ALR1AL4AL4AD2AD4AL4RESTROOM112RESTROOM113PET SPA110HP-145HP-146HP-1476HP-149HP-14977ACL2AD5 AD5AD5AD5AD5AD5AD5AD5AD5AD5 AD5AD5AD5AD2AD2EME3E3E3E3AD5AD5ZONE 1ZONE 2ZONE 3ZONE 4ZONE 5ZONE 6ZONE 7ZONE 8ZONE 8ZONE 9ZONE 9ZONE 10ZONE 11ZONE 12ZONE 13ZONE 14 (BOTH INSTANCES OF AL4)ZONE 15ZONE 16ZONE 17ZONE 18ZONE 19ZONE 20ZONE 21 (ALL INSTANCES OF AL4 ON THIS WALL)NOTE: REFER TO SHEET ID603 FOR NUMBER AND ARRANGEMENT OF AL4 FIXTURES ON THIS WALLNOTE: REFER TO SHEET ID600 FOR NUMBER AND ARRANGEMENT OF AL4 AND ALR1 FIXTURES ON THIS WALLZONE 22ZONE 23ZONE 24ZONE 25ZONE 26ZONE 27ZONE 28ZONE 29ZONE 30ZONE 31ZONE 32ZONE 33ZONE 34ZONE 35ZONE 36ZONE 36ZONE 3689HP-148EMEMEMEMHP-1481010101010101010101010101010RP-GEN3P-GEN4EMAP21111111111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"1ST FL WEST ENLRGDPLAN -LTG & FAE404_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIRST FLOOR WEST ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey ValueKeynote Text1 PROVIDE WEATHERPROOF HORN-STROBE ON BUILDING EXTERIOR. COORDINATE LOCATION WITH LOCAL FIRE DEPARTMENT REQUIREMENTS.2 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANEL SCHEDULES.3 PROVIDE SMOKE DETECTORS WITH AUXILIARY CONTACTS AT ALL ELEVATOR LANDINGS. MAKE AUXILIARY CONNECTION BETWEEN DETECTORS ANDLDU PANELS AS REQUIRED BY ELEVATOR MANUFACTURER. COORDINATE WITH ELEVATOR EQUIPMENT INSTALLATION.4 PROVIDE FIRE ALARM CONNECTION TO SPRINKLER SYSTEM TAMPER AND FLOW SWITCHES. COORDINATE WITH SPRINKLER CONTRACTOR.5 PROVIDE LIGHTING CONTACTOR TO CONTROL RESIDENTIAL LIGHTING ON FIRST FLOOR. CONTACTOR SHALL INCORPORATE OCCUPANCY SENSORSAND PROVIDE INDIVIDUAL CONTROLS FOR LIGHT FIXTURES IN ALL ROOMS. LOCATE CONTACTOR AND PROVIDE USER CONTROL PANEL IN PACKAGEROOM.6 PROVIDE CRESTRON LIGHTING CONTROLLER. SYSTEM SHALL BE COMPRISED OF GLCAEN-FT-120-LV8-LV8-LV8-DIMU8-DIMU8 SYSTEM, GLS-SIMINTEGRATION MODULES, GLNET-CN CONTROL PROCESSOR, KEY PADS, TSW-770-W-S TOUCH SCREEN, AND OCCUPANCY SENSORS AS SHOWN ONDRAWINGS. CONTROLLER SHALL PROVIDE COVERAGE OF ALL AREAS OF FIRST FLOOR, WITH THE EXCEPTION OF BATHROOMS, COMMERCIAL TENANTSPACE, PARKING, WATER SERVICE ROOM, AND UTILITY SPACES.7 PROVIDE CONNECTION TO BUILDING SIGNAGE ILLUMINATION ON SOUTHERN EXTERIOR AND CANOPY. REFER TO ARCHITECTURAL DRAWINGS FORDETAILS. COORDINATE ELECTRICAL CONNECTION TYPE AND LOAD WITH SUBMITTED PRODUCT. PROVIDE ELECTRONIC TIMER TO CONTROLOPERATION.8 FIXTURES IN TRASH ROOM SHALL BE SUSPENDED AT 7'-6" AFF. COORDINATE LOCATIONS AND MOUNTING HEIGHTS WITH MECHANICAL EQUIPMENT.9 FIXTURES IN BIKE ROOM SHALL BE SUSPENDED AT 8'-0" AFF. COORDINATE LOCATIONS AND MOUNTING HEIGHTS WITH MECHANICAL EQUIPMENT.10 AT INDICATED LOCATIONS, PROVIDE DUAL OUTPUT OCCUPANCY SENSOR (BOD: CRESTRON GLA-DT-QUATTRO-COM2-24) TO PROVIDE CONTROL OFEXHAUST. COORDINATE WIRING WITH MECHANICAL CONTRACTOR.E404_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSOR TO CONTROL ALL HALL OR ROOM LIGHTING. OCCUPANCY"ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. REFER TO INTERIOR DESIGN REFLECTED CEILING PLANS FOR DIMENSIONEDLOCATIONS OF LIGHT FIXTURES IN AMENITY SPACES. COORDINATE ALL DEVICE LOCATIONS WITH INTERIOR DESIGN REFLECTED CEILING PLANS AND ELEVATIONS.5. WHERE LIGHTING IS INDICATED WITH ZONE, REFER TO LIGHTING CONTROLLER ZONING DIAGRAM ON E001. FIXTURES ARE TO BE CONTROLLED BY CENTRALIZED LIGHTING CONTROLLER.6. CONTRACTOR SHALL COORDINATE ALL ELECTRICAL RECEPTACLES, LIGHTING, SIGNAGE, AND FIRE ALARM DEVICES WITH ID DRAWINGS PRIOR TO INSTALLATION. REPRESENTATION OF DEVICES ON WALLS ARE SCHEMATIC. FINAL LOCATIONAND MOUNTING HEIGHTS SHALL BE PER ID DRAWINGS. 7. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1 JJJJJJJ/1E4011HP-138NORTHSTAIRREFER TO E101 FOR GENERATORMHP272EWH-1MHP30MHP46233333MHP2ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"1ST FL NORTH ENLRGDPLAN -PWR & DATAE405Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIRST FLOOR NORTH ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.2 PROVIDE CONDUIT AND WIRES FOR DATA AND POWER CONNECTION TO LIFT GATE. ROUTE CONDUIT UNDERSLAB TO GATE. COORDINATECONDUIT ROUTING WITH OTHER SITE WORK.3 PROVIDE CONNECTION TO HEAT TRACE TO DVW AND PRIMARY STORM RISERS IN GARAGE. COORDINATE WITH PLUMBING CONTRACTOR.E405 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. ALL OUTLET LOCATIONS IN AMMENITY SPACES TO BE COORDINATED WITH INTERIOR DESIGN SHEETS.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111 VSSPSP/1E401_R111TTTTTTTTEMEMEMRRREX3NORTHSTAIRP-GEN1E4E4E4E4E4E1E1E5E5E5E5E5E5E5E5P-GEN4S2STORAGE124BMHP44ZONE 37ZONE 36TTTTP-GEN4HP-143ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"1ST FL NORTH ENLRGDPLAN -LTG & FAE405_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIRST FLOOR NORTH ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.E405_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSOR TO CONTROL ALL HALL OR ROOM LIGHTING. OCCUPANCY"ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. REFER TO INTERIOR DESIGN REFLECTED CEILING PLANS FOR DIMENSIONEDLOCATIONS OF LIGHT FIXTURES IN AMENTIY SPACES. COORDINATE ALL DEVICE LOCATIONS WITH INTERIOR DESIGN REFLECTED CEILING PLANS AND ELEVATIONS.5. WHERE LIGHTING IS INDICATED WITH ZONE, REFER TO LIGHTING CONTROLLER ZONING DIAGRAM ON E001. FIXTURES ARE TO BE CONTROLLED BY CENTRALIZED LIGHTING CONTROLLER.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111 GGAGGAGAGAGAGGAGGGGGGGAGAGAGAGAGAGAGAGAGAGAGAGAGAGGAGAGAGAGAGAGAGA11111 1 1111 11GAGAAAAAAAAAUNIT C1201ELEV 1NORTHCORRIDOR238FC-1FC-1FC-2FC-3UNIT B3226UNIT A11232UNIT A12233UNIT C22341111111111FC-3/1E410/1E409/1E408/1E407/1E408NORTHSTAIRUNIT D1223122ECFC-2HP-2M4M5M5M5 M5M5M5800TBFC-33333310" AFF10" AFF10" AFF10" AFF10" AFFP213P231P232P233P234P201HP-138HP-13644444P2311P2312P2314,6P2313P2315P2317P2318P2319,11P23110P23113P23112P23115,17P23118P2321P2322P2323P2324P2327,9P2326P2328P23210P23212P23211,13P2325P23215,17P2333P2336,8P2335P2339P23311,13P2337P2332P2331410" AFFP2344P2341,3P2342P2345P2346P2347,9P2348P23410P23411P23412P23413,15P2011P2012P2013,5P2016P2014P2017P2018P2019P20111,13P20110P20112FC-2P20114,16P20114,16HP-21HP-225ELEVATORLOBBY238P23413,15FC-2P23115,17P2331P23312P23316,18ELEC/DATA237TRASHROOM235ELEV 2CENTRALSTAIR111111T-1HP-211HP-21361HP-24ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"2ND FL CORE ENLRGDPLAN -PWR & DATAE406Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1SECOND FLOOR CORE ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 CONTRACTOR SHALL FURNISH AND INSTALL UNDER-SINK RECEPTACLE FOR CORD CONNECTED GARBAGE DISPOSAL/DISHWASHER.SWITCH LOCATED ABOVE COUNTER SHALL CONTROL LOWER PORTION OF RECEPTACLE.2 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.3 PROVIDE STRONG SM-RBX-EXT-14-WH IN-WALL VERSABOX IN EACH APARTMENT. ROUTE COAX CABLE FROM ELECTRICAL CLOSET ONEACH FLOOR TO EACH VERSABOX. PROVIDE CAT5 CABLE FROM VERSABOX TO EACH DATA LOCATION IN EACH APARTMENT. PROVIDE 15APOWER RECEPTACLE IN EACH BOX.4 RECEPTACLE FOR MICROWAVE/VENT HOOD TO MOUNTED AT 66" AFF, TYP OF ALL. COORDINATE MOUNTING OF RECEPTACLE WITHUPPER CABINETRY INSTALLATION.5 PROVIDE EMERGENCY COMMUNICATIONS SYSTEM TO ALLOW COMMUNICATION BETWEEN EMERGENCY COMMUNICATIONS PANEL (ECP)LOCATED ADJACENT TO FIRE ALARM PANEL IN LOBBY, AND EMERGENCY CALL STATIONS AND SIGNS (EC) LOCATED ADJACENT TOELEVATOR CALL BUTTONS ON ALL FLOORS. SYSTEM SHALL BE AS MANUFACTURED BY RATH COMMUNICATIONS AREA OF REFUGESYSTEMS. SYSTEM SHALL CONSIST OF MAIN PANEL #2500-205FM (PAINTED BLACK), CALL BOX #2100-958NSR, POWER SUPPLY#2500-PWR24, SIGN#7078, AND ALL MISCELLANEOUS HARDWARE AND WIRING TO MAKE A COMPLETE SYSTEM.6 PROVIDE FIBEROPTIC BACKBONE FOR 10GB ETHERNET SWITCH.E406 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11111 D3333DD3333DOSD33SPSPSPSPSPSPSPSPSPSPSPSPSPSP/COVSSPSPSPJJJJJSPSPSPSPELEV 2ELEVATORLOBBY237NORTHCORRIDOR238/1E410_R/1E407_R/1E409_R/1E408_R1111HP-2US UVUBUEUHUHUKUSUVUBUEUHUHUHUHUKUHUEUVUKUKUKUHUSUSUVUBUBUHUBUBUSUVUVUHUHUEUEUBUBUKUKUKUHUHUKUKUKUHUHUHUEAWCAWCUHUBEX2EX2EX2RRRRAWCAWCAWCELEV 1TSFS2P23114P231P23214P233P232P23310P234P23414UBUHP201P20115P20115P-GEN1P-GEN3S2S2S2EM3HP-25HP-25USAWCAWCAWC AWCAWC_BAWCCLC CLCCLCACLCCLCCLCCLCCLCCLCCLCCLCCLCAWCEX2AWC_B4UNIT C1201CENTRALSTAIRTRASHROOM235SOUTHCORRIDOR240UNIT C2234UNIT A12233UNIT A11232UNIT D12231ELEC/DATA237NORTHSTAIRUNIT B322655555P-GEN1111111111111111111111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"2ND FL CORE ENLRGDPLAN -LTG & FAE406_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1SECOND FLOOR CORE ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.2 PROVIDE FIRE ALARM CONNECTION TO SPRINKLER SYSTEM TAMPER AND FLOW SWITCHES. COORDINATE WITH SPRINKLERCONTRACTOR.3 SMOKE DETECTOR LOCATED OUTSIDE TRASH CHUTES SHALL TIE INTO SOLENOID CONTROLLING DISCHARGE DOOR, CAUSING THE DOORTO LOCK UPON ACTIVATION OF FIRE ALARM.4 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.5 PROVIDE WIRING AND BLANK COVER PLATE TO J-BOX LOCATIONS IN ALL BEDROOMS FOR FUTURE INSTALLATION OF BUILDING FIREALARM NOTIFICATION DEVICES. TYPICAL FOR ALL UNITS.E406_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS7. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11 GAGAGAGAGAGAGAGAGAGAGAGAGAGAGAGAGAAGAGAGAGAAGAGAGAAGGGGGGGGGGGGGW111 111111 1111 1AAGGGGGAGAGAGAGAGAGAGAGAGAGA11AAAAAAAGAGAAATELECOM236SOUTHCORRIDOR239FC-2FC-3FC-2FC-2UNIT D2207UNIT D3208UNIT B1209UNIT D1206UNIT A4205UNIT A3204UNIT A2203UNIT A1202SOUTHCORRIDOR239/1E408/1E406FC-2FC-2FC-3FC-3FC-2FC-2FC-3FC-2FC-11111111111233333331111refer to unit 212 sheet E40810" AFF10" AFF10" AFF10" AFF10" AFF10" AFF10" AFF10" AFF10" AFF10" AFFP202P203P205P206P208P209P207HP-137EAST STAIR4444444P2021P2022P2027P2024,6P2023P2028P2029P20210,12P2025P22020P2031P2032P2033P2034,6P2035P2037P2038P20310,12P2039P20311FC-1FC-1P20313,15P20213,15P20211P2051P2052P2053P2054,6P2055P2057P2058P20510,12P2059P20511P20513,15P20514P2065P2063P2067P2066,8P2069P2069P20610P20611P20613P20612P20614P20615,17P2061P2062,4P2076P2077P2077P2078P20710,12P2079P20711P20713P20714P20715P20716,18P20716,18P20716,18P2074P2073,5P2072P2085P2086,8P2087P2083P2082,4P2081P2089P2089P20811P20812P20813P20810P20814P20815,17P20815,17P20815,17P2094,6P2093P2091P2092P2095P2097,9P2098P20912P20910P20911P20913,155P20615,17HP-23HP-21111111HP-212617711ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"2ND FL EAST ENLRGDPLAN -PWR & DATAE407Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1SECOND FLOOR EAST ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 CONTRACTOR SHALL FURNISH AND INSTALL UNDER-SINK RECEPTACLE FOR CORD CONNECTED GARBAGE DISPOSAL/DISHWASHER.SWITCH LOCATED ABOVE COUNTER SHALL CONTROL LOWER PORTION OF RECEPTACLE.2 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.3 PROVIDE STRONG SM-RBX-EXT-14-WH IN-WALL VERSABOX IN EACH APARTMENT. ROUTE COAX CABLE FROM ELECTRICAL CLOSET ONEACH FLOOR TO EACH VERSABOX. PROVIDE CAT5 CABLE FROM VERSABOX TO EACH DATA LOCATION IN EACH APARTMENT. PROVIDE 15APOWER RECEPTACLE IN EACH BOX.4 RECEPTACLE FOR MICROWAVE/VENT HOOD TO MOUNTED AT 66" AFF, TYP OF ALL. COORDINATE MOUNTING OF RECEPTACLE WITHUPPER CABINETRY INSTALLATION.5 PROVIDE 3/4" PAINTED PLYWOOD BACK BOARD FOR TELECOM DISTRIBUTION EQUIPMENT AT EACH FLOOR. MOUNT RECEPTACLES ABOVEPLYWOOD. COORDINATE POWER REQUIREMENTS WITH SERVICE PROVIDER.6 PROVIDE FIBEROPTIC BACKBONE FOR 10GB ETHERNET SWITCH.7 PROVIDE CONNECTION TO HEAT TRACE INSTALLED ON WATER PIPES, PROVIDED BY OTHERS. CONNECT HEAT TRACE TO NEAREST HEATTRACE CIRCUIT IN GARAGE BELOW. COORDINATE WITH PLUMBING CONTRACTOR.E407 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111111111 33DVS33D33DD33D33SPSPSPSPSPSPSPSPSPSPSPSPSPSPSPSPSP3333DDSPSPSPSPJJJJJJJSPSOUTHCORRIDOR239/1E406_R/1E408_R11AWCAWCAWCUSUVUBUEUHUHUHUHUKUSUVUBUEUHUHUHUHUKUHUHUBUBUEUKUSUVUVUCUCUSUSUBUBUBUHUHUHUHUKUKUVUVUBUBUBUHUHUHUKUBUBUKUSUVUVUCUSUBUBUBUHUHUHUKUKUHUEUBUBUEUSUVUBUBUKUKUKUHUHUEUSUBUBUHUHUHUVUSUPUPUVUPUPUVAWCAWC AWCAWCRREX1EX1EX2AWCAWCAWCAWCP202P20214P203P20314UKUKP20516P20717P20816P20914P209P-GEN2S1HP-25CLC CLCAWCAWC_BCLCCLCrefer to unit 212 sheet E408_R2UNIT D1206EAST STAIRUNIT D2207UNIT D3208UNIT B1209UNIT A4205UNIT A3204UNIT A2203UNIT A1202TELECOM236333333P2083P206P20711111111111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"2ND FL EAST ENLRGDPLAN -LTG & FAE407_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1SECOND FLOOR EAST ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.2 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.3 PROVIDE WIRING AND BLANK COVER PLATE TO J-BOX LOCATIONS IN ALL BEDROOMS FOR FUTURE INSTALLATION OF BUILDING FIREALARM NOTIFICATION DEVICES. TYPICAL FOR ALL UNITS.E407_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS 7. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111 GAGAGAGAGGAGAGAGGGAGAGAGAGAAGGAGA111 11 GGGGGAGAGAGAGAGAGAGAGAGAGAGAAA111 1AAAAUNIT D4210UNIT A5211UNIT A6212UNIT A7213UNIT A6214UNIT A7215UNIT A6216UNIT A8217??1111UNIT A8217SOUTHCORRIDOR239/1E409FC-2FC-3FC-1FC-2/1E407/1E40622221111refer to unit 212 this sheetrefer to unit 213 this sheetrefer to unit 212 this sheetrefer to unit 213 this sheet10" AFF10" AFF10" AFF10" AFF10" AFF10" AFF10" AFFP210P211P212P213P2106,8P21014P2105P21011P21017P21013P21016P2102,4P2101P2103P2107,9P2107,9P210193333P2119P21110P21111P2118P2117P2114,6P2118P21113P2112P2113,5P2121P2122P2111P2123P2125P2124,6P2128P2128P21210,12P2129FC-1P21211,13P21214P21215P21115,17P2127P2131P2132P2133P2136P2135P2137,9P2138P2135P21311,13P21315P21314,16P21317P21015P22010P21016HP-2111T-1HP-2111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"2ND FL SOUTH ENLRGDPLAN -PWR & DATAE408Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1SECOND FLOOR SOUTH ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 CONTRACTOR SHALL FURNISH AND INSTALL UNDER-SINK RECEPTACLE FOR CORD CONNECTED GARBAGE DISPOSAL/DISHWASHER.SWITCH LOCATED ABOVE COUNTER SHALL CONTROL LOWER PORTION OF RECEPTACLE.2 PROVIDE STRONG SM-RBX-EXT-14-WH IN-WALL VERSABOX IN EACH APARTMENT. ROUTE COAX CABLE FROM ELECTRICAL CLOSET ONEACH FLOOR TO EACH VERSABOX. PROVIDE CAT5 CABLE FROM VERSABOX TO EACH DATA LOCATION IN EACH APARTMENT. PROVIDE 15APOWER RECEPTACLE IN EACH BOX.3 RECEPTACLE FOR MICROWAVE/VENT HOOD TO MOUNTED AT 66" AFF, TYP OF ALL. COORDINATE MOUNTING OF RECEPTACLE WITHUPPER CABINETRY INSTALLATION.E408 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS 12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1111 33OS33DSPSPSPSPSPSPSPSP/COSPD33DD33SPSPSPSPJJSPSP/1E409_R/1E406_R/1E407_RUBUBUBUCUKUHUHUEUCUSUHUVUSUVUKUHAWCUBP21018USUVUEUHUHUBUHUHUEUSUVUHUHUBUKUHUHUHUHUHUHUKUBUHUHUEUSUVAWCAWCrefer to unit 212 this sheetrefer to unit 213 this sheetrefer to unit 212 this sheetrefer to unit 213 this sheetEX2AWCAWCAWCAWCP210P21114P211P212P21216UHUKP213P21310P201AWCAWCAWCAWC AWCAWCCLC CLCCLCCLCEX2UNIT A8217UNIT A6216UNIT A7215UNIT A6214UNIT A7213UNIT A6212UNIT A5211UNIT D4210SOUTHCORRIDOR2401111111111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"2ND FL SOUTH ENLRGDPLAN -LTG & FAE408_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1SECOND FLOOR SOUTH ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 PROVIDE WIRING AND BLANK COVER PLATE TO J-BOX LOCATIONS IN ALL BEDROOMS FOR FUTURE INSTALLATION OF BUILDING FIREALARM NOTIFICATION DEVICES. TYPICAL FOR ALL UNITS.E408_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS 7. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111 GGAGAGAGAGAGAGAGAGGGGAGAGAGAGAGAGGGGGAGAGAGAGAAGGGGGAGAAAGAGAGAGAG111 111 111111111A AAAAA1111UNIT D5218UNIT B2219UNIT A10225UNIT D7221UNIT A9222UNIT A10223UNIT A9224UNIT D622011111111FC-2FC-2FC-2FC-2FC-1FC-1/1E406/1E408FC-2FC-3FC-3FC-2222222refer to unit 222 this sheetrefer to unit 223 this sheet10" AFF10" AFF10" AFF10" AFFFC-310" AFF10" AFFP218P220P222P221P223333333P2181P2182P2183,5P2184P21810P2189,11P2188P2187P21812P21813P2209P21816,18P21816,18P2193P2192,4P2191P2196,8P2196,8P2195P2193P21912P21913,15P21911P21910P2208P2206P2205P2202P2201,3P2204P2207P21814P22015P22011P22014,16P22013P22012P2211P22024,26P22024,26P2212P2213P2214,6P2215P2217P2219P22110P22112,14P22111P2215P22113P2218FC-3FC-2P22116,18P22116,18P2221P2223P2226P2225,7P22210P22211,13P2222P22212P2229P2237,9P2236P2233P2234P22311P2238,10P2231P2232P2199P2197P219P22018P2228P22215,17P2235111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"2ND FL WEST ENLRGDPLAN -PWR & DATAE409Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1SECOND FLOOR WEST ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 CONTRACTOR SHALL FURNISH AND INSTALL UNDER-SINK RECEPTACLE FOR CORD CONNECTED GARBAGE DISPOSAL/DISHWASHER.SWITCH LOCATED ABOVE COUNTER SHALL CONTROL LOWER PORTION OF RECEPTACLE.2 PROVIDE STRONG SM-RBX-EXT-14-WH IN-WALL VERSABOX IN EACH APARTMENT. ROUTE COAX CABLE FROM ELECTRICAL CLOSET ONEACH FLOOR TO EACH VERSABOX. PROVIDE CAT5 CABLE FROM VERSABOX TO EACH DATA LOCATION IN EACH APARTMENT. PROVIDE 15APOWER RECEPTACLE IN EACH BOX.3 RECEPTACLE FOR MICROWAVE/VENT HOOD TO MOUNTED AT 66" AFF, TYP OF ALL. COORDINATE MOUNTING OF RECEPTACLE WITHUPPER CABINETRY INSTALLATION.E409 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11111 SPSPSPSPSPSPSPSPSPSPSPSPSPSPSP333D333D3333333333DD33D33D333SP3JJJJJJJPSP/1E406_RUEUVUSUCUBUBUKUKUKUHUSUVUCUBUBUHUVUSUVUEUHUBUBUHUHUKUKUKUBUBUCUSUKUKUKUHUHUBUBUHUHUBUBUHUHUSUHUEUHUPUPUKUKUEUSUVUBUBUCUSUVUVUHUKUEUHUHUHUHUHUVUEUHUHUHUHUHUKUHUSUSrefer to unit 222 this sheetrefer to unit 223 this sheetAWCAWCAWC AWCAWCAWCP21815P218P219P21914P220UVUVP22017P221P22115P222P2224P22312AWC AWCAWC_BE6 E6 E6 E6P2231UNIT D5218UNIT B2219UNIT D6220UNIT D7221UNIT A9222UNIT A10223UNIT A9224UNIT A10225ZONE 38CLCCLC222P219142222UH11111111111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"2ND FL WEST ENLRGDPLAN -LTG & FAE409_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1SECOND FLOOR WEST ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.2 PROVIDE WIRING AND BLANK COVER PLATE TO J-BOX LOCATIONS IN ALL BEDROOMS FOR FUTURE INSTALLATION OF BUILDING FIREALARM NOTIFICATION DEVICES. TYPICAL FOR ALL UNITS.E409_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. WHERE LIGHTING IS INDICATED WITH ZONE, REFER TO LIGHTING CONTROLLER ZONING DIAGRAM ON E001. FIXTURES ARE TO BE CONTROLLED BY CENTRALIZED LIGHTING CONTROLLER.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS8. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111 GAGAGAGAGAGAAGAGAGAGAGAGAGAGAGAGAGAAGAGAGAAGAGAGAGAGGGGGGGGGGGGA11111111111111AAAAAUNIT B3226FC-3FC-3FC-3FC-3FC-2FC-2FC-21111111111/1E406UNIT D9228UNIT D10229UNIT D11230UNIT D8227NORTHSTAIRFC-2FC-2FC-2FC-22FC-23333310" AFF10" AFF10" AFF10" AFFP226P227P228P229P230HP-13844444P2267P2266,8P2264P2263,5P2262P2261P2269P22610P22611P22613,15P22616P2279P2278,10P22711P22712P22713P22715,17P22715,17P2272P2273,5P2274P2276P2271P2277P2285P2286P22810P2289,11P2288P2287P22812P22813P22815,17P22815,17P22818P2283P2281P2282,4P2291P2292P2297,9P2295P2298P22910P22911P22912P22913P22914FC-2FC-3P22916,18P22916,18P2303P2305P23014P23013P23011P23012P23010P2308P2307,9P2306P2302,4P23011115ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"2ND FL NORTH ENLRGDPLAN -PWR & DATAE410Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1SECOND FLOOR NORTH ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 CONTRACTOR SHALL FURNISH AND INSTALL UNDER-SINK RECEPTACLE FOR CORD CONNECTED GARBAGE DISPOSAL/DISHWASHER.SWITCH LOCATED ABOVE COUNTER SHALL CONTROL LOWER PORTION OF RECEPTACLE.2 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.3 PROVIDE STRONG SM-RBX-EXT-14-WH IN-WALL VERSABOX IN EACH APARTMENT. ROUTE COAX CABLE FROM ELECTRICAL CLOSET ONEACH FLOOR TO EACH VERSABOX. PROVIDE CAT5 CABLE FROM VERSABOX TO EACH DATA LOCATION IN EACH APARTMENT. PROVIDE 15APOWER RECEPTACLE IN EACH BOX.4 RECEPTACLE FOR MICROWAVE/VENT HOOD TO MOUNTED AT 66" AFF, TYP OF ALL. COORDINATE MOUNTING OF RECEPTACLE WITHUPPER CABINETRY INSTALLATION.5 PROVIDE CONNECTION TO HEAT TRACE INSTALLED ON WATER PIPES, PROVIDED BY OTHERS. CONNECT HEAT TRACE TO NEAREST HEATTRACE CIRCUIT IN GARAGE BELOW. COORDINATE WITH PLUMBING CONTRACTOR.E410 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11111111 33DD33333333DD33334DSPSPSPSPSPSPSPSPSPSPSPSPSPSPSPSPSPJJJJJJJJJSPSP/1E406_R11USUVUBUBUCUKUKUKUHUSUVUBUBUCUKUKUHUHUVUEUHUHUHUHUHUKUKUHUSUSUVUVUBUBUBUBUBUBUBUBUCUCUEUBUBUBUBUBUBUSUSUSUSUSUVUCUKUKUEUVUVUHUHUHUHUEUHUHUVUVUVUPUPUEUKUKUKUPUPEX2RRAWCAWCAWCAWCAWCAWCP226P22612P227P22714P22915P23015P230P229P228P-GEN1AWC_BCLCCLCCLCCLCAWC_B2UNIT D9228UNIT D10229UNIT D11230UNIT D8227MAINTENANCECLOSET238NORTHSTAIRUNIT B322633333P2281433331111111111111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"2ND FL NORTH ENLRGDPLAN -LTG & FAE410_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1SECOND FLOOR NORTH ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.2 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.3 PROVIDE WIRING AND BLANK COVER PLATE TO J-BOX LOCATIONS IN ALL BEDROOMS FOR FUTURE INSTALLATION OF BUILDING FIREALARM NOTIFICATION DEVICES. TYPICAL FOR ALL UNITS.E410_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS. 3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. COORDINATE ALL POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS.7. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11 /1E415/1E413/1E414/1E41211800TBM5 M5 M5 M5M5M4M5refer to unit 231 sheet E406refer to unit 232 sheet E406refer to unit 233 sheet E406refer to unit 234 sheet E406refer to unit 201 sheet E406refer to unit 226 sheet E410HP-136HP-138HP-26HP-27HP-29UNIT B3326NORTHSTAIRUNIT D12331NORTHCORRIDOR339UNIT A11332UNIT A12333UNIT C2334ELEC/DATA337TRASHROOM335ELEV 2ELEV 1ELEVATORLOBBY338UNIT C1301CENTRALSTAIRSOUTHCORRIDOR3401111EC21113HP-21541ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"3RD FL CORE ENLRGDPLAN -PWR & DATAE411Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1THIRD FLOOR CORE ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.2 PROVIDE EMERGENCY COMMUNICATIONS SYSTEM TO ALLOW COMMUNICATION BETWEEN EMERGENCY COMMUNICATIONS PANEL (ECP)LOCATED ADJACENT TO FIRE ALARM PANEL IN LOBBY, AND EMERGENCY CALL STATIONS AND SIGNS (EC) LOCATED ADJACENT TOELEVATOR CALL BUTTONS ON ALL FLOORS. SYSTEM SHALL BE AS MANUFACTURED BY RATH COMMUNICATIONS AREA OF REFUGESYSTEMS. SYSTEM SHALL CONSIST OF MAIN PANEL #2500-205FM (PAINTED BLACK), CALL BOX #2100-958NSR, POWER SUPPLY#2500-PWR24, SIGN#7078, AND ALL MISCELLANEOUS HARDWARE AND WIRING TO MAKE A COMPLETE SYSTEM.3 REFER TO UNIT D14 ON DRAWING E425 FOR TYPICAL BALCONY POWER REQUIRMENTS. WIRE 120V, 20A, RECEPTACLE ON BALCONY TOLOCAL APARTMENT PANEL.4 PROVIDE FIBEROPTIC BACKBONE FOR 10GB ETHERNET SWITCH.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1E411 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS11 SPSPSPOSVSSPSPSPSPSPSP/COSPSPSP/1E415_R/1E414_R/1E413_R/1E412_R1111refer to unit 201 sheet E406refer to unit 226 sheet E410refer to unit 231 sheet E406refer to unit 232 sheet E406refer to unit 233 sheet E406refer to unit 234 sheet E406EX1EX2EX1EX2RRRRTSFS2P-GEN1P-GEN33S2S2S2HP-210HP-210EX2AWCAWCAWCAWCAWCAWCAWCAWCAWCAWC_BAWCAWC_BCLCCLCCLCCLCCLCCLCCLCACLCCLCCLCCLC CLCAWC_B4UNIT B3326NORTHSTAIRNORTHCORRIDOR339UNIT D12331UNIT A11332UNIT A12333UNIT C2334ELEC/DATA337TRASHROOM335ELEVATORLOBBY338ELEV 2ELEV 1CENTRALSTAIRUNIT C13011111141111111115ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"3RD FL CORE ENLRGDPLAN -LTG & FAE411_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1THIRD FLOOR CORE ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.2 PROVIDE FIRE ALARM CONNECTION TO SPRINKLER SYSTEM TAMPER AND FLOW SWITCHES. COORDINATE WITH SPRINKLERCONTRACTOR.3 SMOKE DETECTOR LOCATED OUTSIDE TRASH CHUTES SHALL TIE INTO SOLENOID CONTROLLING DISCHARGE DOOR, CAUSING THE DOORTO LOCK UPON ACTIVATION OF FIRE ALARM.4 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.5 REFER TO UNIT D14 ON DRAWING E425_R FOR TYPICAL BALCONY LIGHTING REQUIRMENTS. WIRE BALCONY LIGHT AND RECEEPTACLE TOLINE SIDE OF LIVING ROOM LIGHT CIRCUIT.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1E411_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS11 AA/1E413/1E4111refer to unit 202 sheet E407refer to unit 203 sheet E407refer to unit 212 sheet E408refer to unit 205 sheet E407refer to unit 206 sheet E407refer to unit 207 sheet E407refer to unit 208 sheet E407refer to unit 209 sheet E407HP-137HP-282UNIT A1302UNIT A2303UNIT A3304TELECOM336UNIT A4305UNIT B1309UNIT D1306UNIT D2307EAST STAIRUNIT D330811113333HP-21441ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"3RD FL EAST ENLRGDPLAN -PWR & DATAE412Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1THIRD FLOOR EAST ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.2 PROVIDE 3/4" PAINTED PLYWOOD BACK BOARD FOR TELECOM DISTRIBUTION EQUIPMENT AT EACH FLOOR. MOUNT RECEPTACLES ABOVEPLYWOOD. COORDINATE POWER REQUIREMENTS WITH SERVICE PROVIDER.3 REFER TO UNIT D14 ON DRAWING E425 FOR TYPICAL BALCONY POWER REQUIRMENTS. WIRE 120V, 20A, RECEPTACLE ON BALCONY TOLOCAL APARTMENT PANEL.4 PROVIDE FIBEROPTIC BACKBONE FOR 10GB ETHERNET SWITCH.E412 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11111 SPVSSPSPSPSPSPSP/1E413_R/1E411_R11refer to unit 202 sheet E407refer to unit 203 sheet E407refer to unit 212 sheet E408refer to unit 205 sheet E407refer to unit 206 sheet E407refer to unit 207 sheet E407refer to unit 208 sheet E407refer to unit 209 sheet E407EX1EX1RRP-GEN2S1HP-210AWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWC_BCLCCLCCLCCLC2TELECOM336UNIT A1302UNIT A2303UNIT A3304UNIT A4305UNIT B1309UNIT D1306EAST STAIRUNIT D2307UNIT D3308SOUTHCORRIDOR3401111113333ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"3RD FL EAST ENLRGDPLAN -LTG & FAE412_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1THIRD FLOOR EAST ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.2 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.3 REFER TO UNIT D14 ON DRAWING E425_R FOR TYPICAL BALCONY LIGHTING REQUIRMENTS. WIRE BALCONY LIGHT AND RECEEPTACLE TOLINE SIDE OF LIVING ROOM LIGHT CIRCUIT.E412_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE..7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11111 /1E414/1E411/1E412refer to unit 210 sheet E408refer to unit 211 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408HP-26UNIT D4310UNIT A5311UNIT A6312SOUTHCORRIDOR340UNIT A7313UNIT A6314UNIT A7315UNIT A6316UNIT A83171111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"3RD FL SOUTH ENLRGDPLAN -PWR & DATAE413Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1THIRD FLOOR SOUTH ENLARGED PLAN - POWER & DATAE413 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET VSSP/COSPSPSP/1E414_R/1E411_Rrefer to unit 210 sheet E408refer to unit 211 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408EX2HP-210EX2AWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWC_BCLCCLC CLCCLCUNIT A8317UNIT A6316UNIT A7315UNIT A6314UNIT A7313UNIT A6312UNIT A5311UNIT D43101111111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"3RD FL SOUTH ENLRGDPLAN -LTG & FAE413_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1THIRD FLOOR SOUTH ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote TextE413_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET /1E413/1E411refer to unit 218 sheet E409refer to unit 219 sheet E409refer to unit 220 sheet E409refer to unit 221 sheet E409refer to unit 202 sheet E407refer to unit 203 sheet E407refer to unit 202 sheet E407refer to unit 223 sheet E409UNIT D5318UNIT A14325UNIT A13324UNIT A14323UNIT A13322UNIT D7321UNIT D6320UNIT B231911ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"3RD FL WEST ENLRGDPLAN -PWR & DATAE414Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1THIRD FLOOR WEST ENLARGED PLAN - POWER & DATAE414 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1 SPSP/1E411_R/1E413_Rrefer to unit 218 sheet E409refer to unit 219 sheet E409refer to unit 220 sheet E409refer to unit 221 sheet E409refer to unit 202 sheet E407refer to unit 203 sheet E407refer to unit 202 sheet E407refer to unit 223 sheet E409AWCAWCAWCAWCAWCAWCAWCAWCAWC_BCLCCLC1UNIT A14325UNIT A13324UNIT A14323UNIT A13322UNIT D7321UNIT D6320UNIT B2319UNIT D53181111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"3RD FL WEST ENLRGDPLAN -LTG & FAE414_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1THIRD FLOOR WEST ENLARGED PLAN - LIGHTING & FIRE ALARME414_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SETKEYNOTE LEGENDKey Value Keynote Text1 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.1 /1E4111refer to unit 226 sheet E410refer to unit 227 sheet E410refer to unit 228 sheet E410refer to unit 229 sheet E410refer to unit 230 sheet E410HP-138UNIT D9328UNIT D10329UNIT D11330UNIT D8327UNIT B3326MAINTENANCECLOSET338NORTHSTAIR1112222ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"3RD FL NORTH ENLRGDPLAN -PWR & DATAE415Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1THIRD FLOOR NORTH ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.2 REFER TO UNIT D14 ON DRAWING E425 FOR TYPICAL BALCONY POWER REQUIRMENTS. WIRE 120V, 20A, RECEPTACLE ON BALCONY TOLOCAL APARTMENT PANEL.E415 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111111 SPSPSPSPSP/1E411_R11refer to unit 226 sheet E410refer to unit 227 sheet E410refer to unit 228 sheet E410refer to unit 229 sheet E410refer to unit 230 sheet E410EX1EX2RRP-GEN1AWCAWCAWCAWCAWCAWCAWC_BCLCCLCCLCCLCAWC_B2UNIT D9328UNIT D10329UNIT D8327UNIT D11330UNIT B3326NORTHSTAIRNORTHCORRIDOR339MAINTENANCECLOSET3381111113333ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"3RD FL NORTH ENLRGDPLAN -LTG & FAE415_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1THIRD FLOOR NORTH ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.2 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.3 REFER TO UNIT D14 ON DRAWING E425_R FOR TYPICAL BALCONY LIGHTING REQUIRMENTS. WIRE BALCONY LIGHT AND RECEEPTACLE TOLINE SIDE OF LIVING ROOM LIGHT CIRCUIT.E415_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111111 /1E417/1E419/1E418/1E42011800TBM5 M5 M5 M5 M5M4M3HP-4refer to unit 231 sheet E406refer to unit 232 sheet E406refer to unit 233 sheet E406refer to unit 234 sheet E406refer to unit 201 sheet E406refer to unit 226 sheet E410HP-138HP-1362UNIT B3426NORTHSTAIRNORTHCORRIDOR439UNIT D12431UNIT A11432UNIT A12433UNIT C2434ELEC/DATA437TRASHROOM435ELEV 2ELEV 1ELEVATORLOBBY438CENTRALSTAIRUNIT C140111111EC13HP-42HP-41541ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"4TH FL CORE ENLRGDPLAN -PWR & DATAE416Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FOURTH FLOOR CORE ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.2 PROVIDE EMERGENCY COMMUNICATIONS SYSTEM TO ALLOW COMMUNICATION BETWEEN EMERGENCY COMMUNICATIONS PANEL (ECP)LOCATED ADJACENT TO FIRE ALARM PANEL IN LOBBY, AND EMERGENCY CALL STATIONS AND SIGNS (EC) LOCATED ADJACENT TOELEVATOR CALL BUTTONS ON ALL FLOORS. SYSTEM SHALL BE AS MANUFACTURED BY RATH COMMUNICATIONS AREA OF REFUGESYSTEMS. SYSTEM SHALL CONSIST OF MAIN PANEL #2500-205FM (PAINTED BLACK), CALL BOX #2100-958NSR, POWER SUPPLY#2500-PWR24, SIGN#7078, AND ALL MISCELLANEOUS HARDWARE AND WIRING TO MAKE A COMPLETE SYSTEM.3 REFER TO UNIT D14 ON DRAWING E425 FOR TYPICAL BALCONY POWER REQUIRMENTS. WIRE 120V, 20A, RECEPTACLE ON BALCONY TOLOCAL APARTMENT PANEL.4 PROVIDE FIBEROPTIC BACKBONE FOR 10GB ETHERNET SWITCH.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1E416 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS11 SPSPVSOSSPSPSPSPSP/COSPSPSPSP/1E420_R/1E420_R/1E419_R/1E417_R1111refer to unit 201 sheet E406refer to unit 226 sheet E410refer to unit 231 sheet E406refer to unit 232 sheet E406refer to unit 233 sheet E406refer to unit 234 sheet E406EX2EX1EX2EX1RRRRTSFS2P-GEN1P-GEN3HP-4S2S2EMS23HP-45HP-45EX2AWCAWCAWCAWCAWCAWCAWCAWCAWCAWC_BAWC_BCLCCLCCLCCLCCLCCLCCLCCLCCLCACLCCLC CLCAWC_B4UNIT B3426NORTHCORRIDOR439UNIT D12431UNIT A11432UNIT A12433UNIT C2434ELEC/DATA437TRASHROOM435ELEV 2ELEV 1ELEVATORLOBBY438CENTRALSTAIRUNIT C14014NORTHSTAIRP-GEN134111111111111115ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"4TH FL CORE ENLRGDPLAN -LTG & FAE416_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FOURTH FLOOR CORE ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.2 PROVIDE FIRE ALARM CONNECTION TO SPRINKLER SYSTEM TAMPER AND FLOW SWITCHES. COORDINATE WITH SPRINKLERCONTRACTOR.3 SMOKE DETECTOR LOCATED OUTSIDE TRASH CHUTES SHALL TIE INTO SOLENOID CONTROLLING DISCHARGE DOOR, CAUSING THE DOORTO LOCK UPON ACTIVATION OF FIRE ALARM.4 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.5 REFER TO UNIT D14 ON DRAWING E425_R FOR TYPICAL BALCONY LIGHTING REQUIRMENTS. WIRE BALCONY LIGHT AND RECEEPTACLE TOLINE SIDE OF LIVING ROOM LIGHT CIRCUIT.E416_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111 AA/1E418/1E4161refer to unit 202 sheet E407refer to unit 203 sheet E407refer to unit 212 sheet E408refer to unit 205 sheet E407refer to unit 206 sheet E407refer to unit 207 sheet E407refer to unit 208 sheet E407refer to unit 209 sheet E407HP-137HP-432UNIT A1402UNIT A2403UNIT A3404UNIT A4405UNIT B1409UNIT D1406EAST STAIRUNIT D2407UNIT D3408SOUTHCORRIDOR440TELECOM436111111113333HP-41441ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"4TH FL EAST ENLRGDPLAN -PWR & DATAE417Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FOURTH FLOOR EAST ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.2 PROVIDE 3/4" PAINTED PLYWOOD BACK BOARD FOR TELECOM DISTRIBUTION EQUIPMENT AT EACH FLOOR. MOUNT RECEPTACLES ABOVEPLYWOOD. COORDINATE POWER REQUIREMENTS WITH SERVICE PROVIDER.3 REFER TO UNIT D14 ON DRAWING E425 FOR TYPICAL BALCONY POWER REQUIRMENTS. WIRE 120V, 20A, RECEPTACLE ON BALCONY TOLOCAL APARTMENT PANEL.4 PROVIDE FIBEROPTIC BACKBONE FOR 10GB ETHERNET SWITCH.E417 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111111 SPVSSPSPSPSPSPSP/1E418_R/1E416_R11refer to unit 202 sheet E407refer to unit 203 sheet E407refer to unit 212 sheet E408refer to unit 205 sheet E407refer to unit 206 sheet E407refer to unit 207 sheet E407refer to unit 208 sheet E407refer to unit 209 sheet E407EX1EX1EX2RRP-GEN2HP-45AWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWC_BCLCCLCCLC2UNIT A1402UNIT A2403UNIT A3404TELECOM436UNIT A4405UNIT D1406UNIT D2407UNIT D3408UNIT B1409CLC1111113333ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"4TH FL EAST ENLRGDPLAN -LTG & FAE417_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FOURTH FLOOR EAST ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.2 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.3 REFER TO UNIT D14 ON DRAWING E425_R FOR TYPICAL BALCONY LIGHTING REQUIRMENTS. WIRE BALCONY LIGHT AND RECEEPTACLE TOLINE SIDE OF LIVING ROOM LIGHT CIRCUIT.E417_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11 /1E419/1E416/1E417refer to unit 210 sheet E408refer to unit 211 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408SOUTHCORRIDOR440UNIT D4410UNIT A5411UNIT A6412UNIT A7413UNIT A6414UNIT A7415UNIT A6416UNIT A841711111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"4TH FL SOUTH ENLRGDPLAN -PWR & DATAE418Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FOURTH FLOOR SOUTH ENLARGED PLAN - POWER & DATAE418 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1 SP/COSPSPSP/1E420_R/1E419_R/1E417_Rrefer to unit 210 sheet E408refer to unit 211 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408EX2RFSEX2AWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWC_BCLCCLC CLCCLCUNIT D4410UNIT A5411UNIT A6412UNIT A7413UNIT A6414UNIT A7415UNIT A6416UNIT A8417111111111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"4TH FL SOUTH ENLRGDPLAN -LTG & FAE418_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FOURTH FLOOR SOUTH ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.E418_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1 GAGAAGAGGGGAGAGAGAGAGAGAGAGGGWGW11111AAGW11FC-211/1E418/1E416FC-322P422P420refer to unit 218 sheet E409refer to unit 202 sheet E407refer to unit 203 sheet E407refer to unit 202 sheet E4073310" AFFFC-1P420210" AFFP42013P42014P4209P4205P4204P4207P4206,8P4203P42010,12P42011P42015FC-1FC-3P42016P42017,19P42017,19P42017,1910" AFF10" AFF10" AFF10" AFF10" AFF10" AFFP4227P4229P4226,8P4223P4222P42210,12P42211P4221P4225P42213P42214,16P4221510" AFFUNIT D5418UNIT D13420UNIT B4422UNIT A15423UNIT A13424UNIT A1442510" AFFCIRCUIT TO 20A BREAKER IN PANEL P418ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"4TH FL WEST ENLRGDPLAN -PWR & DATAE419Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FOURTH FLOOR WEST ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 CONTRACTOR SHALL FURNISH AND INSTALL UNDER-SINK RECEPTACLE FOR CORD CONNECTED GARBAGE DISPOSAL/DISHWASHER.SWITCH LOCATED ABOVE COUNTER SHALL CONTROL LOWER PORTION OF RECEPTACLE.2 PROVIDE STRONG SM-RBX-EXT-14-WH IN-WALL VERSABOX IN EACH APARTMENT. ROUTE COAX CABLE FROM ELECTRICAL CLOSET ONEACH FLOOR TO EACH VERSABOX. PROVIDE CAT5 CABLE FROM VERSABOX TO EACH DATA LOCATION IN EACH APARTMENT. PROVIDE 15APOWER RECEPTACLE IN EACH BOX.3 RECEPTACLE FOR MICROWAVE/VENT HOOD TO MOUNTED AT 66" AFF, TYP OF ALL. COORDINATE MOUNTING OF RECEPTACLE WITHUPPER CABINETRY INSTALLATION.E419 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111 SP33DD33SPSPSPSPSPSPSPJJJSP/1E416_RUKUKUHUHUHUBUBUCUEUSUSUEUEUHUHUBUBUBUBUVUVUHUHUPUPUPUPUKUKUKUCUSUVrefer to unit 218 sheet E409refer to unit 202 sheet E407refer to unit 203 sheet E407refer to unit 202 sheet E407AWCAWCP420P42018P422P42217E2E2P42217AWCAWCAWCAWCAWC_BCLCCLC1UNIT D5418UNIT D13420UNIT B4422UNIT A15423UNIT A13424UNIT A14425SOUTHCORRIDOR440222111E2TO LINE SIDE OF LIVING SPACE LIGHTING CIRCUIT 3ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"4TH FL WEST ENLRGDPLAN -LTG & FAE419_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FOURTH FLOOR WEST ENLARGED PLAN - LIGHTING & FIRE ALARME419_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SETKEYNOTE LEGENDKey Value Keynote Text1 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.2 PROVIDE WIRING AND BLANK COVER PLATE TO J-BOX LOCATIONS IN ALL BEDROOMS FOR FUTURE INSTALLATION OF BUILDING FIREALARM NOTIFICATION DEVICES. TYPICAL FOR ALL UNITS.3 EXTERIOR FIXTURE ONLY OCCURS IN UNIT 418.111 /1E4161refer to unit 226 sheet E410refer to unit 227 sheet E410refer to unit 228 sheet E410refer to unit 229 sheet E410refer to unit 230 sheet E410HP-138UNIT D9428UNIT D10429UNIT D11430UNIT D8427MAINTENANCECLOSET438UNIT B3426NORTHSTAIR12222ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"4TH FL NORTH ENLRGDPLAN -PWR & DATAE420Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FOURTH FLOOR NORTH ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.2 REFER TO UNIT D14 ON DRAWING E425 FOR TYPICAL BALCONY POWER REQUIRMENTS. WIRE 120V, 20A, RECEPTACLE ON BALCONY TOLOCAL APARTMENT PANEL.E420 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111111 SPSPSPSPSP/1E416_R11refer to unit 226 sheet E410refer to unit 227 sheet E410refer to unit 228 sheet E410refer to unit 229 sheet E410refer to unit 230 sheet E410EX2EX1RRP-GEN1AWCAWCAWCAWCAWCAWC_BCLCCLCCLCCLCAWC_B2UNIT D9428UNIT D10429UNIT D8427UNIT D11430MAINTENANCECLOSET438UNIT B3426NORTHSTAIR1111113333ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"4TH FL NORTH ENLRGDPLAN -LTG & FAE420_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FOURTH FLOOR NORTH ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.2 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.3 REFER TO UNIT D14 ON DRAWING E425_R FOR TYPICAL BALCONY LIGHTING REQUIRMENTS. WIRE BALCONY LIGHT AND RECEEPTACLE TOLINE SIDE OF LIVING ROOM LIGHT CIRCUIT.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1111E420_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS11 /1E424/1E423/1E422/1E42511EC800TBM5 M5M5 M5 M5M5M4refer to unit 201 sheet E406refer to unit 231 sheet E406refer to unit 232 sheet E406refer to unit 233 sheet E406refer to unit 234 sheet E406HP-138HP-1362UNIT D14527NORTHSTAIRUNIT D12531NORTHCORRIDOR539UNIT A11532UNIT A12533UNIT C2534ELEC/DATA537TRASHROOM535UNIT C1501ELEV 2ELEV 1CENTRALSTAIRELEVATORLOBBY5381111EC113HP-48HP-41341ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"5TH FL CORE ENLRGDPLAN -PWR & DATAE421Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIFTH FLOOR CORE ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.2 PROVIDE EMERGENCY COMMUNICATIONS SYSTEM TO ALLOW COMMUNICATION BETWEEN EMERGENCY COMMUNICATIONS PANEL (ECP)LOCATED ADJACENT TO FIRE ALARM PANEL IN LOBBY, AND EMERGENCY CALL STATIONS AND SIGNS (EC) LOCATED ADJACENT TOELEVATOR CALL BUTTONS ON ALL FLOORS. SYSTEM SHALL BE AS MANUFACTURED BY RATH COMMUNICATIONS AREA OF REFUGESYSTEMS. SYSTEM SHALL CONSIST OF MAIN PANEL #2500-205FM (PAINTED BLACK), CALL BOX #2100-958NSR, POWER SUPPLY#2500-PWR24, SIGN#7078, AND ALL MISCELLANEOUS HARDWARE AND WIRING TO MAKE A COMPLETE SYSTEM.3 REFER TO UNIT D14 ON DRAWING E425 FOR TYPICAL BALCONY POWER REQUIRMENTS. WIRE 120V, 20A, RECEPTACLE ON BALCONY TOLOCAL APARTMENT PANEL.4 PROVIDE FIBEROPTIC BACKBONE FOR 10GB ETHERNET SWITCH.12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1E421 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS11 SPVSOSSPSPHFSPSPSP/COSPSPSPSP/1E425_R/1E424_R/1E422_R/1E423_R1111refer to unit 201 sheet E406refer to unit 231 sheet E406refer to unit 232 sheet E406refer to unit 233 sheet E406refer to unit 234 sheet E406RREX1EX2RRAWCEX2EX1EX1TSFS2P-GEN3P-GEN13S2S2S24HP-411HP-411EX2AWCAWCAWCAWCAWCAWCAWCAWCAWCAWC_BCLCACLCCLCCLCCLCCLCAWC_BCLCCLCCLCCLCCLCAWC_B5NORTHSTAIRUNIT D14527UNIT D12531NORTHCORRIDOR539UNIT A11532UNIT A12533ELEC/DATA537UNIT C2534TRASHROOM535UNIT C1501CENTRALSTAIRELEV 2ELEV 1ELEVATORLOBBY538511111111116ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"5TH FL CORE ENLRGDPLAN -LTG & FAE421_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIFTH FLOOR CORE ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.2 PROVIDE FIRE ALARM CONNECTION TO SPRINKLER SYSTEM TAMPER AND FLOW SWITCHES. COORDINATE WITH SPRINKLERCONTRACTOR.3 SMOKE DETECTOR LOCATED OUTSIDE TRASH CHUTES SHALL TIE INTO SOLENOID CONTROLLING DISCHARGE DOOR, CAUSING THE DOORTO LOCK UPON ACTIVATION OF FIRE ALARM.4 PROVIDE HEAT DETECTOR (FIXED TEMPERATURE) WITHIN 2'-0" of SPRINKLER HEADS IN TRASH CHUTE, WHERE THEY OCCUR.INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA 72.5 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.6 REFER TO UNIT D14 ON DRAWING E425_R FOR TYPICAL BALCONY LIGHTING REQUIRMENTS. WIRE BALCONY LIGHT AND RECEEPTACLE TOLINE SIDE OF LIVING ROOM LIGHT CIRCUIT.E421_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11 AA/1E423/1E4211refer to unit 202 sheet E407refer to unit 203 sheet E407refer to unit 212 sheet E408refer to unit 205 sheet E407refer to unit 206 sheet E407refer to unit 207 sheet E407refer to unit 208 sheet E407refer to unit 209 sheet E407HP-137HP-4102TELECOM536UNIT A1502UNIT A2503UNIT A3504UNIT D3508UNIT B1509UNIT A4505UNIT D1506EAST STAIRUNIT D250711113333HP-4741ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"5TH FL EAST ENLRGDPLAN -PWR & DATAE422Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIFTH FLOOR EAST ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.2 PROVIDE 3/4" PAINTED PLYWOOD BACK BOARD FOR TELECOM DISTRIBUTION EQUIPMENT AT EACH FLOOR. MOUNT RECEPTACLES ABOVEPLYWOOD. COORDINATE POWER REQUIREMENTS WITH SERVICE PROVIDER.3 REFER TO UNIT D14 ON DRAWING E425 FOR TYPICAL BALCONY POWER REQUIRMENTS. WIRE 120V, 20A, RECEPTACLE ON BALCONY TOLOCAL APARTMENT PANEL.4 PROVIDE FIBEROPTIC BACKBONE FOR 10GB ETHERNET SWITCH.E422 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111111 SPSPVSSPSPSPSPSP/1E423_R/1E424_R11refer to unit 202 sheet E407refer to unit 203 sheet E407refer to unit 212 sheet E408refer to unit 205 sheet E407refer to unit 206 sheet E407refer to unit 207 sheet E407refer to unit 208 sheet E407refer to unit 209 sheet E407RREX1EX1EX2P-GEN2S1HP-411AWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWC_BCLCCLCCLCCLC2TELECOM536UNIT A4505UNIT A3504UNIT A2503UNIT A1502UNIT D1506EAST STAIRUNIT D2507UNIT B1509UNIT D3508SOUTHCORRIDOR5401111113333ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"5TH FL EAST ENLRGDPLAN -LTG & FAE422_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIFTH FLOOR EAST ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.2 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.3 REFER TO UNIT D14 ON DRAWING E425_R FOR TYPICAL BALCONY LIGHTING REQUIRMENTS. WIRE BALCONY LIGHT AND RECEEPTACLE TOLINE SIDE OF LIVING ROOM LIGHT CIRCUIT.E422_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET111111 /1E424/1E422/1E421refer to unit 210 sheet E408refer to unit 211 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408UNIT A8517UNIT A6516UNIT A7515UNIT A6514UNIT A7513UNIT A6512UNIT A5511UNIT D4510111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"5TH FL SOUTH ENLRGDPLAN -PWR & DATAE423Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIFTH FLOOR SOUTH ENLARGED PLAN - POWER & DATAE423 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1 VSSP/COSPSPSP/1E424_R/1E421_Rrefer to unit 210 sheet E408refer to unit 211 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408refer to unit 212 sheet E408refer to unit 213 sheet E408REX1EX2FSHP-411EX2AWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWCAWC_BCLCCLCCLCCLC1UNIT A8517UNIT A6516UNIT A7515UNIT A6514UNIT A7513UNIT A6512UNIT A5511UNIT D4510SOUTHCORRIDOR54011111111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"5TH FL SOUTH ENLRGDPLAN -LTG & FAE423_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIFTH FLOOR SOUTH ENLARGED PLAN - LIGHTING & FIRE ALARMKEYNOTE LEGENDKey Value Keynote Text1 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.E423_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET1 /1E423/1E421refer to unit 218 sheet E409refer to unit 420 sheet E419refer to unit 422 sheet E419refer to unit 202 sheet E407refer to unit 203 sheet E407refer to unit 202 sheet E407UNIT A14525UNIT A13524UNIT A15523UNIT B4522UNIT D13520SOUTHCORRIDOR540UNIT D55181ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"5TH FL WEST ENLRGDPLAN -PWR & DATAE424Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIFTH FLOOR WEST ENLARGED PLAN - POWER & DATAE424 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11KEYNOTE LEGENDKey Value Keynote Text1 REFER TO UNIT D14 ON DRAWING E425 FOR TYPICAL BALCONY POWER REQUIRMENTS. WIRE 120V, 20A, RECEPTACLE ON BALCONY TOLOCAL APARTMENT PANEL.1 SP/1E423_R/1E421_Rrefer to unit 218 sheet E409refer to unit 420 sheet E419refer to unit 422 sheet E419refer to unit 202 sheet E407refer to unit 203 sheet E407refer to unit 202 sheet E407AWCAWCAWCAWCAWCAWCAWC_BCLC CLC1UNIT A14525UNIT A13524UNIT A15523UNIT B4522UNIT D13520UNIT D55182ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"5TH FL WEST ENLRGDPLAN -LTG & FAE424_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIFTH FLOOR WEST ENLARGED PLAN - LIGHTING & FIRE ALARME424_R GENERAL NOTES1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SETKEYNOTE LEGENDKey Value Keynote Text1 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.2 REFER TO UNIT D14 ON DRAWING E425_R FOR TYPICAL BALCONY LIGHTING REQUIRMENTS. WIRE BALCONY LIGHT AND RECEEPTACLE TOLINE SIDE OF LIVING ROOM LIGHT CIRCUIT.11 GWGWGWGGGAGAGAGAGAGAGAGGGAGAAA111 11AAGWACFC-3FC-1FC-1/1E42112210" AFF10" AFF10" AFF10" AFF10" AFF3333P530P527HP-13844P5274P5273,5P5278P52710P52710P52711P52714,16P52713P5271P5272P52712P5279P5276P5277P52715,17P52715,17P5301P5302P5305,7P5304P5303P5306P5309,11P5308P53010P53012P53013,15P53013,15HP-49FC-1FC-3UNIT B5530UNIT D14527NORTHSTAIR1P53017HP-41651ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"5TH FL NORTH ENLRGDPLAN -PWR & DATAE425Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIFTH FLOOR NORTH ENLARGED PLAN - POWER & DATAKEYNOTE LEGENDKey Value Keynote Text1 ALL RECEPTACLES WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TOPANEL SCHEDULES.2 PROVIDE STRONG SM-RBX-EXT-14-WH IN-WALL VERSABOX IN EACH APARTMENT. ROUTE COAX CABLE FROM ELECTRICAL CLOSET ONEACH FLOOR TO EACH VERSABOX. PROVIDE CAT5 CABLE FROM VERSABOX TO EACH DATA LOCATION IN EACH APARTMENT. PROVIDE 15APOWER RECEPTACLE IN EACH BOX.3 CONTRACTOR SHALL FURNISH AND INSTALL UNDER-SINK RECEPTACLE FOR CORD CONNECTED GARBAGE DISPOSAL/DISHWASHER.SWITCH LOCATED ABOVE COUNTER SHALL CONTROL LOWER PORTION OF RECEPTACLE.4 RECEPTACLE FOR MICROWAVE/VENT HOOD TO MOUNTED AT 66" AFF, TYP OF ALL. COORDINATE MOUNTING OF RECEPTACLE WITHUPPER CABINETRY INSTALLATION.5 PROVIDE DATA CABLING FOR CONNECTION TO WIFI ABOVE CEILING. PROVIDE EXTRA 15' CABLE COILED UP ABOVE CEILING, PROVIDEDUPLEX RECEPTACLE MOUNTED TO STRUCTURE ABOVE CEILING AND CIRCUITING AS SHOWN.E425 GENERAL NOTES1. MECHANICAL CONTRACTOR TO FURNISH AC DISCONNECT FOR ALL HVAC EQUIPMENT. ELECTRICAL CONTRACTOR TO INSTALL AND COMPLETE ELECTRICAL CONNECTIONS TO DISCONNECTS AND EQUIPMENT, TYPICAL OF ALL.2. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS IN ALL APARTMENTS, UNLESSOTHERWISE NOTED. MEASUREMENTS ARE TO CENTERLINE OF DEVICES:A. CONVENIENCE RECEPTACLES: 18" ABOVE FINISHED FLOORB. ABOVE COUNTER CONVENIENCE RECEPTACLES: MAXIMUM 46" ABOVE FINISHED FLOORC. ABOVE DESK CONVENIENCE RECEPTACLES: MAXIMUM 44" ABOVE FINISHED FLOORD. LIGHT SWITCHES: MAXIMUM 48" ABOVE FINISHED FLOORE. DEDICATED EQUIPMENT RECEPTACLES:a. ABOVE COUNTER: 44" ABOVE FINISHED FLOORb. STANDARD: 18" ABOVE FINISHED FLOORF. DATA AND TV CABLE RECEPTACLES: 18" ABOVE FINISHED FLOORG. RANGE RECEPTACLE: 6" ABOVE FINISHED FLOOR3.COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11111 SPSPSPSPSPSPSP3D33D3JJJSPSP/1E421_R11UBUBUSUCUKUKUPUPUHUHUBUBUSUHUHUSUHUHUHUPUPUKUEUVUVRRAWCAWCEX2EX1UCUKUVUVP52718P527P530P53014P-GEN1UBUBE1AWCE2E2P52718CLCCLCCLCCLCAWC_BP-GEN142UNIT B5530NORTHSTAIRUNIT D145273331111ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTION1/4" = 1'-0"5TH FL NORTH ENLRGDPLAN -LTG & FAE425_RTaitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECT1/4" = 1'-0"1FIFTH FLOOR NORTH ENLARGED PLAN - LIGHTING & FIRE ALARME425_R GENERAL NOTESKEYNOTE LEGENDKey Value Keynote Text1 ALL LIGHTING WITHIN EACH STAIRWELL SHALL BE SERVED BY A DEDICATED BRANCH CIRCUIT TO EACH STAIRWELL. REFER TO PANELSCHEDULES.2 ALL CORRIDOR AND OTHER EMERGENCY LIGHTING ON FLOORS 2-5 TO BE POWERED BY GENERATOR AS EMERGENCY EGRESS LIGHTING.REFER TO GENERATOR PANEL (P-GEN) SCHEDULE FOR CIRCUITING DETAILS.3 PROVIDE WIRING AND BLANK COVER PLATE TO J-BOX LOCATIONS IN ALL BEDROOMS FOR FUTURE INSTALLATION OF BUILDING FIREALARM NOTIFICATION DEVICES. TYPICAL FOR ALL UNITS.1. STAIR LIGHTING SHALL HAVE INTEGRATED OCCUPANCY SENSOR TO CONTROLINDIVIDUAL FIXTURE. FIXTURES SHALL DIM TO 25% LIGHT OUTPUT AFTER 5 MINUTES OF INACTIVITY.2. OCCUPANCY SENSORS TO CONTROL ALL CORRIDOR LIGHTING. OCCUPANCY "ON-TIME" TO BE 5 MINUTES. UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.3. ALL EXIT SIGNAGE SHALL BE FED FROM CIRCUITS SUPPORTED BY GENERATOR.4. FIXTURES DESIGNATED WITH "EM" WILL BE CIRCUITED SEPARATELY AND SUPPORTED BY GENERATOR, PROVIDING EMERGENCY EGRESS LIGHTING.5. NOTIFICATION DEVICES IN APARTMENTS SHALL TIE INTO BUILDING FIRE ALARM SYSTEM TO ALERT RESIDENTS UPON INITIATION OF BUILDING FIRE ALARM. MULTISTATION SMOKE ALARMS IN APARTMENTS SHALL BE INDEPENDENT OF BUILDING FIRE ALARM SYSTEM AND ONLY SOUND UPON DETECTION OF SMOKE.6. CORRIDOR LIGHTING TO BE HARDWIRED TO HIGH/LOW STANDALONE DIMMINGOCCUPANCY CONTROL WITH 0-10V AND/OR PHASE DIMMING CONTROL AS REQUIRED, TIMEOUT AND LOW END OUTPUT TO BE FIELD ADJUSTABLE.7. COORDINATE ALL CORRIDOR POWER, LIGHTING, LIGHTING CONTROLS, AND FIRE ALARM DEVICES WITH ID DRAWINGS12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET11 ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTIONPANEL SCHEDULESE501Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECTNotes:Receptacle 720 VA 100.00% 720 VATotal Est. Demand Current:151 AElectric Heat 1000 VA 65.00% 650 VATotal Conn. Current:182 ADwelling Unit - Lighting 98 VA 100.00% 98 VATotal Est. Demand:54392 VAPower 32009 VA 86.25% 27607 VATotal Conn. Load:65473 VAOther 31646 VA 80.00% 25317 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsTotal Amps:238 A 179 A 139 ATotal Load:27892 VA 20855 VA 16727 VA6566636461625960575855 -- -- -- 0 VA5653 SPARE (FUTURE EV CHARGING STATION) 40 A 2 0 VA 0 VA -- -- -- 5451 -- -- -- 5404... 0 VA 2 40 A SPARE (FUTRE EV CHARGING STATION) 5249 -- -- -- 5404... 360 VA 1 20 A RECEPTACLES - TELECOM 5047 ELEVATOR 2 45 A 3 5404... 1600... 1 20 A ELEV 2 CAR LIGHTING 4845 -- -- -- 0 VA 1176... 1 20 A GATE OPERATOR 4643 EDH-4 (FC-5) 30 A 2 4300... 98 VA 1 20 A LIGHTING - STORAGE 4441 -- -- -- 0 VA 0 VA -- -- -- 4239 EDH-4 (FC-7) 30 A 2 4300... 3000... 2 20 A EDH-2 (ERV-8) 4037 -- -- -- 0 VA 0 VA -- -- -- 3835 EDH-2 (ERV-6) 20 A 2 3000... 2460... 2 20 A EDH-3 (FC-6) 3633 -- -- -- 0 VA 0 VA -- -- -- 3431 EDH-1 (ERV-5) 25 A 2 4000... 3000... 2 20 A EDH-2 (ERV-7) 3229 EWH-1 (EAST STAIR) 20 A 1 0 VA 0 VA 1 20 A EWH-1 (NORTH STAIR) 3027 GATE OPERATOR 20 A 1 1176... 0 VA 1 20 A EWH-1 (ELEC RM 122) 2825 BRASCH CONTROLLER 15 A 1 125 VA 2102... -- -- -- 2623 -- -- -- 0 VA 2102... -- -- -- 2421 ERV-8 15 A 2 1019... 2102... 3 35 A TRASH COMPACTOR 2219 -- -- -- 291 VA 500 VA -- -- -- 2017 FAN COILS 15 A 2 411 VA 500 VA 2 15 A EBH-1 (LOBBY) 1815 -- -- -- 0 VA 0 VA -- -- -- 1613 ERV-6 15 A 2 2246... 2246... 2 15 A ERV-7 14110 VA -- -- -- 129 QUAD RECEPTACLE ETHERNET SWITCH 20 A 1 180 VA 1248... 2 15 A ERV-5 107 -- -- -- 0 VA 1250... 1 20 A STORM/DHW HEAT TRACE 85 -- -- -- 0 VA 1250... 1 20 A STORM/DHW HEAT TRACE 63 G-ATS 150 A 3 0 VA 1250... 1 20 A STORM/DHW HEAT TRACE 41 RECEPTACLES - BENCHES 400 A 1 720 VA 1250... 1 20 A STORM/DHW HEAT TRACE 2CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKTNotes:Enclosure:1MCB Rating:1200 AMounting:SurfaceWires:4Mains Rating:1200 ASupply From: Phases:3Mains Type:MLOLocation: Volts:120/208 WyeA.I.C. Rating:10kABranch Panel: MHPNotes:Total Est. Demand Current:78 ATotal Conn. Current:107 ATotal Est. Demand:16160 VATotal Conn. Load:22320 VAReceptacle 22320 VA 72.40% 16160 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsTotal Amps:110 A 104 A 0 ATotal Load:11520 VA 10800 VA 0 VA4142394037383536333431322930272825262324212219201718151613 RECEPTACLES - YOGA 20 A 1 360 VA 360 VA 1 20 A RECEPTACLES - GYM 1411 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 129 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 107 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 85 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 63 EQUIPMENT 20 A 1 1800... 1800... 1 20 A EQUIPMENT 41 EQUIPMENT 20 A 1 1800... 1800... 1 20 A EQUIPMENT 2CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKTNotes:Enclosure:1MCB Rating:225 AMounting:SurfaceWires:3Mains Rating:225 ASupply From: Phases:1Mains Type:MLOLocation: Volts:120/208 SingleA.I.C. Rating:10kABranch Panel: P-GYMNotes:Receptacle 16380 VA 80.53% 13190 VAElectric Heat 3500 VA 65.00% 2275 VATotal Est. Demand Current:107 ADwelling Unit - Lighting 512 VA 100.00% 512 VATotal Conn. Current:126 APower 20137 VA 89.93% 18110 VATotal Est. Demand:38551 VAOther 1507 VA 80.00% 1206 VATotal Conn. Load:45295 VALighting 3259 VA 100.00% 3259 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsTotal Amps:82 A 141 A 171 ATotal Load:9817 VA 15938 VA 19541 VA7172697067686566636461 RECEPTACLE LIGHTING CONTROL DEVICE 20 A 1 180 VA6259 LIGHTING CONTROLLER 20 A 1 236 VA 319 VA 1 20 A LIGHTING CONTROLLER 6057 LIGHTING CONTROLLER 20 A 1 335 VA 185 VA 1 20 A LIGHTING CONTROLLER 5855 LIGHTING CONTROLLER 20 A 1 92 VA 93 VA 1 20 A LIGHTING CONTROLLER 5653 LIGHTING CONTROLLER 20 A 1 312 VA 596 VA 1 20 A LIGHTING CONTROLLER 5451 LIGHTING CONTROLLER 20 A 1 846 VA 260 VA 1 20 A LIGHTING CONTROLLER 5249 LIGHTING - BUILDING SIGNAGE 20 A 1 1000... 300 VA 1 20 A POWER - DOOR OPERATOR 5047 LIGHTING - ELEV 1 PIT 20 A 1 15 VA 256 VA 1 20 A LIGHTING - WATER SERV RM, PET RELIEF 4845 LIGHTING - RESTROOM 112/113 20 A 1 64 VA 15 VA 1 20 A LIGHTING - ELEV 2 PIT 4643 LIGHTING - PARKING (NON-EMERG) 20 A 1 841 VA 512 VA 1 20 A LIGHTING - UT CORR, TELECOM 4441 -- -- -- 1750... 1334... 1 20 A SPRINKLER COMPRESSOR 4239 ELECTRIC HEAT - UT CORR, TELECOM 20 A 2 1750... 720 VA 1 20 A RECEPTACLES - UT CORR, TELECOM 4037 RECEPTACLES - EAST STAIR 20 A 1 900 VA 900 VA 1 20 A RECEPTACLES - NORTH STAIR 3835 RECEPTACLE - ELEV 2 PIT 20 A 1 180 VA 900 VA 1 20 A RECEPTACLES - CENTRAL STAIR 3633 ELEV 1 SUMP PUMP 20 A 1 180 VA 180 VA 1 20 A RECEPTACLE - ELEV 1 PIT 3431 RECEPTACLES - EXTERIOR 20 A 1 360 VA 180 VA 1 20 A ELEV 2 SUMP PUMP 3229 FIREPLACE (GFI) 20 A 1 1800... 1080... 1 20 A RECEPTACLE - WIFI RESIDENT LOUNGE 3027 POWER - BOTTLE FILLER 20 A 1 1000... 360 VA 1 20 A RECEPTACLES - WATER SVC, TRASH 2825 RECEPTACLES - RESTRM 112/113 20 A 1 360 VA 720 VA 1 20 A RECEPTACLES - PET SPA/RELIEF 2623 RECEPTACLES - LOBBY 20 A 1 1080... 540 VA1 20 A RECEPTACLES - LEASING OFFICE 2421 RECEPTACLES - PATIO 20 A 1 360 VA 180 VA 120 A RECEPTACLE - RES LNGE KITCH TV 2219 RES LNGE D/W 20 A 1 180 VA 360 VA 1 20 A RECEPTACLES - RES LNGE ISLAND 2017 -- -- -- 4000... 3163... -- -- -- 1815 RES LNGE COOKTP 40 A 2 4000... 3163... 2 40 A RES LNGE STOVE 1613 RECEPTACLES - RES LNGE KITCH 20 A 1360 VA 138 VA 1 20 A RES LNGE KITCH VENT 1411 RECEPTACLES - RES LOUNGE TVS 20 A 1 360 VA 360 VA 1 20 A RECEPTACLES - RES LNGE KITCH 129 RECEPTACLES - RES LOUNGE 20 A 1 540 VA 1080... 1 20 A RECEPTACLES - RES LOUNGE 107 RES LOUNGE FLOOR BOXES 20 A 1 720 VA 540 VA 1 20 A RECEPTACLES - RES LOUNGE 85 RECEPTACLES - PCKG, MAIL RMS 20 A 1 900 VA 360 VA 1 20 A RECEPTACLES - BIKE RM 63 Power 20 A 1 360 VA 360 VA 1 20 A RECEPTACLES - LOBBY COUNTER 41 RECEPTACLES - EXIT CORR 20 A 1 540 VA 540 VA 1 20 A LOBBY FLOOR BOXES 2CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKTNotes:Enclosure:1MCB Rating:400 AMounting:SurfaceWires:4Mains Rating:400 ASupply From: Phases:3Mains Type:MLOLocation: Volts:120/208 WyeA.I.C. Rating:10kABranch Panel: HP-112.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SETNotes:Receptacle 360 VA 100.00% 360 VATotal Est. Demand Current:65 ADwelling Unit - Lighting 34 VA 100.00% 34 VATotal Conn. Current:71 APower 18650 VA 90.72% 16920 VATotal Est. Demand:23534 VAOther 2282 VA 80.00% 1826 VATotal Conn. Load:25721 VALighting 4394 VA 100.00% 4394 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsTotal Amps:74 A 68 A 77 ATotal Load:8791 VA 8132 VA 9198 VA2930272825 Receptacle 20 A 1 180 VA2623 EMERGENCY LIGHTS (1ST FLOOR) 20 A 1 838 VA 180 VA 1 20 A REC. BUTTERFLYMX SYSTEM 2421 FACP 20 A 1 200 VA 200 VA 1 20 A REMOTE ANNUNCIATOR 2219 -- -- -- 5404... 1040... -- -- -- 2017 -- -- -- 5404... 1040... 2 15 A HP-8 (ELEV 1) 1815 ELEVATOR 1 45 A 3 5404... 1600... 1 20 A ELEV 1 CAR LIGHTING 1613 EMERGENCY LIGHTING (4TH FLOOR) 20 A 1 752 VA 702 VA 1 20 A EMERGENCY LIGHTING (5TH FLOOR) 1411 EMERGENCY LIGHTING (2ND FLOOR) 20 A 1 797 VA 780 VA 1 20 A EMERGENCY LIGHTING (3RD FLOOR) 129 EXIT SIGNS (4TH FLOOR) 20 A 1 40 VA 45 VA 1 20 A EXIT SIGNS (5TH FLOOR) 107 EXIT SIGNS (2ND FLOOR) 20 A 1 25 VA 40 VA 1 20 A EXIT SIGNS (3RD FLOOR) 85 LIGHTING - EXIT CORR 125 20 A 1 118 VA 40 VA 1 20 A EXIT SIGNS (1ST FLOOR) 63 LIGHTING - CENTRAL STAIR 20 A 1 382 VA 261 VA1 20 A LIGHTING - PARKING (EMERGENCY) 41 LIGHTING - NORTH STAIR 20 A 1 323 VA 323 VA 1 20 A LIGHTING - EAST STAIR 2CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKTNotes:Enclosure:1MCB Rating:225 AMounting:SurfaceWires:4Mains Rating:225 ASupply From: Phases:3Mains Type:MLOLocation: Volts:120/208 WyeA.I.C. Rating:10kABranch Panel: P-GEN ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTIONPANEL SCHEDULESE502Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECTNotes:Total Est. Demand Current:17 AReceptacle 4680 VA 100.00% 4680 VATotal Conn. Current:17 ADwelling Unit - Lighting 149 VA 100.00% 149 VATotal Est. Demand:6269 VAPower 1440 VA 100.00% 1440 VATotal Conn. Load:6269 VAOther 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsTotal Amps:21 A 15 A 16 ATotal Load:2520 VA 1800 VA 1949 VA414239403738353633343132293027282526232421221920171815 QUAD RECEPTACLE ETHERNET SWITCH 20 A 1 180 VA 180 VA 1 20 A RECEPTACLE WIRELESS ACCESS POINT 1613 QUAD RECEPTACLE ETHERNET SWITCH 20 A 1 180 VA180 VA 1 20 A QUAD RECEPTACLE ETHERNET SWITCH 1411 LIGHTING - 5TH FL ELEC, TRASH, TELECOM 20 A 1 83 VA 1080... 1 20 A Receptacle 129 RECEPTACLES - 5TH FL PATIO 20 A 1 360 VA 360 VA 1 20 A RECEPTACLES - 5TH FL TELECOM 107 QUAD RECEPTACLE ETHERNET SWITCH 20 A 1 180 VA 900 VA 1 20 A RECEPTACLES CORRIDOR 85 LIGHTING - 4TH FL ELEC, TRASH, TELECOM 20 A 1 66 VA 720 VA 1 20 A Receptacle 63 RECEPTACLES - 4TH FL TELECOM 20 A 1 360 VA 360 VA 1 20 A Receptacle 41 RECEPTACLES - 4TH FL EAST 20 A 1 180 VA 900 VA 1 20 A Receptacle 2CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKTNotes:Enclosure:1MCB Rating:225 AMounting:SurfaceWires:4Mains Rating:225 ASupply From: Phases:3Mains Type:MLOLocation: Volts:120/208 WyeA.I.C. Rating:10kABranch Panel: HP-4Notes:Total Est. Demand Current:883 AReceptacle 2160 VA 100.00% 2160 VATotal Conn. Current:1055 APower 72284 VA 82.77% 59827 VATotal Est. Demand:317943 VAOther 248671 VA 80.00% 198937 VATotal Conn. Load:380134 VAHVAC 57019 VA 100.00% 57019 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsTotal Amps:2305 A 463 A 413 ATotal Load:275784 VA 54778 VA 49572 VA65666364616259605758555653545152495047484546434441423940372400... -- -- -- 38352400... -- -- -- 36332400... 3 250 A WH-1 34311040... -- -- -- 3229 -- -- -- 1748... 1040... 2 15 A HP-8 (ELEV 2) 3027 -- -- -- 2099... 900 VA 1 20 A RECEPTACLES - ROOF 2825 P-DHW 400 A 3 1905... 3328... -- -- -- 2623 RECEPTACLES - ROOF 20 A 1 1080... 3328... 2 40 A HP-5 (FITNESS, YOGA) 2421 -- -- -- 3120... 3120... -- -- -- 2219 HP-4 (BIKE RM) 50 A 2 3120... 3120... 2 50 A HP-4 (TRASH RM) 2017 -- -- -- 2642... 0 VA -- -- -- 1815 HP-7 (LOBBY) 40 A 2 2642... 0 VA -- -- -- 1613 EF-2 15 A 1 667 VA 3819... 3 20 A EF-1 1411 -- -- -- 0 VA 0 VA -- -- -- 129 -- -- -- 0 VA 0 VA -- -- -- 107 ERV-4 175 A 3 6092... 5223... 3 150 A ERV-3 85 -- -- -- 0 VA 0 VA -- -- -- 63 -- -- -- 0 VA 0 VA -- -- -- 41 ERV-2 150 A 3 5223... 5223... 3 150 A ERV-1 2CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKTNotes:Enclosure:1MCB Rating:1200 AMounting:SurfaceWires:4Mains Rating:1200 ASupply From: Phases:3Mains Type:MLOLocation: Volts:120/208 WyeA.I.C. Rating:10kABranch Panel: P-ROOFNotes:Total Est. Demand Current:160 AReceptacle 180 VA 100.00% 180 VATotal Conn. Current:160 APower 284 VA 100.00% 284 VATotal Est. Demand:57521 VAOther 48 VA 80.00% 38 VATotal Conn. Load:57531 VAHVAC 57019 VA 100.00% 57019 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsTotal Amps:161 A 177 A 146 ATotal Load:19052 VA 20997 VA 17482 VA717269706768656663646162596057 RECEPTACLE - PENTHOUSE 20 A 1 180 VA5855 MIXING VALVE (MV-1) 20 A 1 48 VA 34 VA 1 20 A ZONE VALVES (Z-1, Z-2) 5653161 VA 1 20 A RECIRCUL PUMP (P-2A) 54511560... -- -- -- 52491560... 2 15 A SANDEN UNIT (HPWH-1) 5047 -- -- -- 1560... 1560... -- -- -- 4845 SANDEN UNIT (HPWH-1) 15 A 2 1560...1560... 2 15 A SANDEN UNIT (HPWH-1) 4643 -- -- -- 1560... 1560... -- -- -- 4441 SANDEN UNIT (HPWH-1) 15 A 2 1560...1560... 2 15 A SANDEN UNIT (HPWH-1) 4239 -- -- -- 1560... 1560... -- -- -- 4037 SANDEN UNIT (HPWH-1) 15 A 2 1560...1560... 2 15 A SANDEN UNIT (HPWH-1) 3835 -- -- -- 1560... 1560... -- -- -- 3633 SANDEN UNIT (HPWH-1) 15 A 2 1560...1560... 2 15 A SANDEN UNIT (HPWH-1) 34311560... -- -- -- 32291560... 2 15 A SANDEN UNIT (HPWH-1) 3027 -- -- -- 1560... 1560... -- -- -- 2825 SANDEN UNIT (HPWH-1) 15 A 2 1560...1560... 2 15 A SANDEN UNIT (HPWH-1) 2623 -- -- -- 1560... 1560... -- -- -- 2421 SANDEN UNIT (HPWH-1) 15 A 2 1560...1560... 2 15 A SANDEN UNIT (HPWH-1) 2219 -- -- -- 1560... 1560... -- -- -- 2017 SANDEN UNIT (HPWH-1) 15 A 2 1560...1560... 2 15 A SANDEN UNIT (HPWH-1) 1815 -- -- -- 1560... 1560... -- -- -- 1613 SANDEN UNIT (HPWH-1) 15 A 2 1560...1560... 2 15 A SANDEN UNIT (HPWH-1) 1411 RECIRCUL PUMP (P-2B) 20 A 1 161 VA129 RECIRCUL PUMP (P-1) 20 A 1 537 VA107856341 SANDEN HEAT TRACE 20 A 1 250 VA2CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKTNotes:Enclosure:1MCB Rating:400 AMounting:SurfaceWires:4Mains Rating:400 ASupply From:P-ROOFPhases:3Mains Type:MLOLocation: Volts:120/208 WyeA.I.C. Rating:10kABranch Panel: P-DHW12.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SETNotes:Total Est. Demand Current:22 AReceptacle 6480 VA 100.00% 6480 VATotal Conn. Current:22 ADwelling Unit - Lighting 149 VA 100.00% 149 VATotal Est. Demand:8069 VAPower 1440 VA 100.00% 1440 VATotal Conn. Load:8069 VAOther 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsTotal Amps:33 A 23 A 14 ATotal Load:3780 VA 2603 VA 1686 VA414239403738353633343132293027282526232421221920171815 QUAD RECEPTACLE ETHERNET SWITCH 20 A 1 180 VA1613 QUAD RECEPTACLE ETHERNET SWITCH 20 A 1 180 VA180 VA 1 20 A QUAD RECEPTACLE ETHERNET SWITCH 1411 RECEPTACLE - ROOF 20 A 1 180 VA 180 VA 1 20 A QUAD RECEPTACLE - ETHERNET SWITCH 129 RECEPTACLES - 3RD FL NORTH 20 A 1 1080... 83 VA 120 A LIGHTING - 3RD FL ELEC, TRASH, TELECOM 107 RECEPTACLES - 3RD FL WEST 20 A 1 1080... 360 VA 1 20 A RECEPTACLES - 3RD FL TELECOM 85 LIGHTING - 2ND FL ELEC, TRASH, TELECOM 20 A 166 VA 1260... 1 20 A RECEPTACLES - 3RD FL EAST 63 RECEPTACLES - 2ND FL TELECOM 20 A 1 360 VA 900 VA 1 20 A RECEPTACLES - 2ND FL NORTH 41 RECEPTACLES - 2ND FL EAST 20 A 1 900 VA 1080... 1 20 A RECEPTACLES - 2ND FL WEST 2CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKTNotes:Enclosure:1MCB Rating:225 AMounting:SurfaceWires:4Mains Rating:225 ASupply From: Phases:3Mains Type:MLOLocation: Volts:120/208 WyeA.I.C. Rating:10kABranch Panel: HP-211111 ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTIONPANEL SCHEDULESE503Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECTNotes:Total Est. Demand Current:0 ATotal Conn. Current:0 ATotal Est. Demand:0 VATotal Conn. Load:0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsTotal Amps:0 A0 A0 ATotal Load:0 VA 0 VA 0 VA414239403738353633343132293027282526232421221920171815161314111291078563412CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKTNotes:Enclosure:1MCB Rating:600 AMounting:SurfaceWires:4Mains Rating:600 ASupply From: Phases:3Mains Type:MLOLocation: Volts:120/208 WyeA.I.C. Rating:10kABranch Panel: CP2Notes:Total Est. Demand Current:0 ATotal Conn. Current:0 ATotal Est. Demand:0 VATotal Conn. Load:0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsTotal Amps:0 A0 A0 ATotal Load:0 VA 0 VA 0 VA414239403738353633343132293027282526232421221920171815161314111291078563412CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKTNotes:Enclosure:1MCB Rating:600 AMounting:SurfaceWires:4Mains Rating:600 ASupply From: Phases:3Mains Type:MLOLocation: Volts:120/208 WyeA.I.C. Rating:10kABranch Panel: CP312.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SETNotes:Total Est. Demand Current:35 AReceptacle 1440 VA 100.00% 1440 VATotal Conn. Current:66 AElectric Heat 21500 VA 48.72% 10475 VATotal Est. Demand:12587 VADwelling Unit - Lighting 288 VA 100.00% 288 VATotal Conn. Load:23708 VAOther 480 VA 80.00% 384 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsTotal Amps:75 A 71 A 55 ATotal Load:8790 VA 8268 VA 6650 VA414239403738353633343132293027282526232421 LIGHTING 20 A 1 768 VA2219 -- -- -- 750 VA 540 VA 1 20 A EXTERIOR RECEPTACLES 2017 ELECTRIC HEAT 20 A 2 750 VA 900 VA 1 20 A RECEPTACLES 1815 -- -- -- 1250... 1250... -- -- -- 1613 Electric Heat 20 A 2 1250... 1250... 2 20 A ELECTRIC HEAT 1411 -- -- -- 1250... 1250... -- -- -- 129 ELECTRIC HEAT 20 A 2 1250... 1250... 2 20 A ELECTRIC HEAT 107 -- -- -- 1250... 1250... -- -- -- 85 ELECTRIC HEAT 20 A 2 1250... 1250... 2 20 A ELECTRIC HEAT 63 -- -- -- 1250... 1250... -- -- -- 41 ELECTRIC HEAT 20 A 2 1250... 1250... 2 20 A ELECTRIC HEAT 2CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKTNotes:Enclosure:1MCB Rating:600 AMounting:SurfaceWires:4Mains Rating:600 ASupply From: Phases:3Mains Type:MLOLocation: Volts:120/208 WyeA.I.C. Rating:10kABranch Panel: CP1 ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTIONPANEL SCHEDULESE504Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECTTYPICAL FOR APARTMENTS 305, 405, AND 505.Notes:Total Est. Demand...86 AReceptacle 5380 VA 100.00% 5380 VATotal Conn. Current:90 APower 10600 VA 98.87% 10480 VATotal Est. Demand:17,986 VAOther 2658 VA 80.00% 2126 VATotal Conn. Load:18,638 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:86 A 92 ATotal Load:8965 VA 9673 VA29302728252623242122-- -- -- 1165 VA / 0 VA 2017,19 HP-1 (ROOF) 15 A 2 1165 / 018-- -- -- 0 VA / 88 VA 1 15 A LIGHTING (AFCI) 1613,15 FAN COILS 15 A 2 60 / 180 1 15 A RECEPTACLE - TELECOM (AFCI) 1411 RECEPTACLES - LIVING ROOM (AFCI) 15 A 1 540 VA / 4000 VA -- -- --9 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 / 4000 2 40 A RECEPTACLE - STOVE 10,127 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 VA / 540 VA 1 20 A RECEPTACLES - KITCHEN (AFCI) 85 RECEPTACLE - FRIDGE, DINING RM... 20 A 1 360 / 1300 -- -- --3 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 VA / 1300... 2 30 A Power 4,61 RECEPTACLE - BATHROOM 20 A 1 180 / 720 1 15 A RECEPTACLES - BEDROOM (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:STUDIO 8Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P205TYPICAL FOR APARTMENTS 306, 406, AND 506.Notes:Total Est. Demand...83 AReceptacle 6280 VA 100.00% 6280 VATotal Conn. Current:84 APower 10600 VA 98.87% 10480 VATotal Est. Demand:17,189 VAOther 536 VA 80.00% 429 VATotal Conn. Load:17,416 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:88 A 78 ATotal Load:9320 VA 8096 VA293027282526232421221920-- -- -- 0 / 01815,17 FAN COILS 15 A 2 180 VA / 176 VA 1 15 A LIGHTING (AFCI) 1613 RECEPTACLE - BATHROOM 20 A 1 180 / 7201 15 A RECEPTACLES - BEDROOM (AFCI) 1411 RECEPTACLES - BEDROOM (AFCI) 15 A 1 720 VA / 180 VA 1 20 A RECEPTACLE - BATHROOM 129 RECEPTACLES - HALL, LIV ROOM... 15 A 1 720 / 180 1 15 A RECEPTACLE - TELECOM (AFCI) 107 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 VA / 4000... -- -- --5 RECEPTACLES - KITCHEN (AFCI) 20 A 1 720 / 4000 2 40 A RECEPTACLE - STOVE 6,83 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 VA / 1300 VA -- -- --1 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 / 1300 2 30 A RECEPTACLE - DRYER 2,4CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 9Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P206TYPICAL FOR APARTMENTS 307, 407, AND 507.Notes:Total Est. Demand...94 AReceptacle 6280 VA 100.00% 6280 VATotal Conn. Current:98 APower 10600 VA 98.87% 10480 VATotal Est. Demand:19,551 VAOther 3488 VA 80.00% 2791 VATotal Conn. Load:20,368 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:101 A 94 ATotal Load:10601 VA 9767 VA2930272825262324-- -- -- 1487 / 02219,21 HP-3 (ROOF) 20 A 2 1487 VA / 0 VA 2017 LIGHTING (AFCI) 15 A 1 154 / 0 -- -- --15 RECEPTACLES - BEDROOM (AFCI) 15 A 1720 VA / 180 VA 2 15 A FAN COILS 16,1813 RECEPTACLE - BATHROOM 20 A 1 180 / 7201 15 A RECEPTACLES - BEDROOM (AFCI) 1411 RECEPTACLE - BATHROOM20 A 1 180 VA / 1300 VA -- -- --9 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 / 1300 2 30 A RECEPTACLE - DRYER 10,127 RECEPTACLES - HALL, LIV ROOM... 15 A 1 720 VA / 180 VA 1 15 A RECEPTACLE - TELECOM (AFCI) 8-- -- -- 4000 / 540 1 20 A RECEPTACLES - KITCHEN (AFCI) 63,5 RECEPTACLE - STOVE 40 A 2 4000 VA / 1000... 1 20 A RECEPTACLE - MICROWAVE/VENT... 41 RECEPTACLE - FRIDGE, KITCHEN... 20 A 1 360 / 360 1 20 A RECEPTACLES - KITCHEN (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 10Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P207TYPICAL FOR APARTMENTS 308, 408, AND 508.Notes:Total Est. Demand...96 AReceptacle 6640 VA 100.00% 6640 VATotal Conn. Current:100 APower 10600 VA 98.87% 10480 VATotal Est. Demand:19,911 VAOther 3488 VA 80.00% 2791 VATotal Conn. Load:20,728 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:103 A 95 ATotal Load:10807 VA 9921 VA29302728252623242122190 VA / 1487 VA -- -- ---- -- -- 0 / 1487 2 20 A HP-3 (ROOF) 18,2015,17 FAN COILS 15 A 2 180 VA / 154 VA 1 15 A LIGHTING (AFCI) 1613 RECEPTACLE - BATHROOM 20 A 1 180 / 1801 15 A RECEPTACLE - TELECOM (AFCI) 1411 RECEPTACLES - BEDROOM (AFCI) 15 A 1 900 VA / 180 VA 1 20 A RECEPTACLE - BATHROOM 129 RECEPTACLES - HALL, LIV ROOM... 15 A 1 720 / 720 1 15 A RECEPTACLES - BEDROOM (AFCI) 107 RECEPTACLES - KITCHEN (AFCI) 20 A 1 720 VA / 1300 VA -- -- --5 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 / 1300 2 30 A RECEPTACLE - DRYER 6,83 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 VA / 4000... -- -- --1 RECEPTACLES - KITCHEN (AFCI) 20 A 1 720 / 4000 2 40 A RECEPTACLE - STOVE 2,4CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 11Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P208TYPICAL FOR APARTMENTS 309, 409, AND 509.Notes:Total Est. Demand...94 AReceptacle 5560 VA 100.00% 5560 VATotal Conn. Current:98 APower 10600 VA 98.87% 10480 VATotal Est. Demand:19,454 VAOther 4268 VA 80.00% 3414 VATotal Conn. Load:20,428 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:103 A 91 ATotal Load:10933 VA 9494 VA29302728252623242122192017 0 / 1934 -- -- ---- -- -- 0 VA / 1934 VA 2 30 A HP-2 (ROOF) 16,1813,15 FAN COILS 15 A 2 120 / 99 1 15 A LIGHTING (AFCI) 1411 RECEPTACLE - BATHROOM 20 A 1 180 VA / 900 VA 1 15 A RECEPTACLES - BEDROOM (AFCI) 12-- -- -- 1300 / 720 1 15 A RECEPTACLES - LIVING ROOM (AFCI) 107,9 RECEPTACLE - DRYER 30 A 2 1300 VA / 180 VA 1 15 A RECEPTACLE - TELECOM (AFCI) 85 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 / 4000 -- -- --3 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 VA / 4000... 2 40 A RECEPTACLE - STOVE 4,61 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 / 720 1 20 A RECEPTACLES - KITCHEN (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:1 BR 12Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P209Typical for apartments 310, 410, and 510.Notes:Total Est. Demand...103 AReceptacle 6280 VA 100.00% 6280 VATotal Conn. Current:110 APower 13000 VA 95.38% 12400 VATotal Est. Demand:21,480 VAOther 3499 VA 80.00% 2800 VATotal Conn. Load:22,779 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:108 A 110 ATotal Load:11272 VA 11507 VA2930272825262324212219 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 VA / 0 VA 2017 RECEPTACLE - TELECOM (AFCI) 15 A 1 180 / 165 1 20 A LIGHTING (AFCI) 1815 RECEPTACLES - KITCHEN (AFCI) 20 A 1 360 VA / 900 VA 1 15 A RECEPTACLES - HALL, LIV ROOM... 1613 RECEPTACLES - BEDROOM (AFCI) 15 A 1 720 / 540 1 20 A RECEPTACLES - KITCHEN (AFCI) 1411 RECEPTACLES - BEDROOM (AFCI) 15 A 1 900 VA / 1487 VA -- -- ---- -- -- 0 / 1487 2 20 A HP-3 (ROOF) 10,127,9 FAN COILS 15 A 2 180 VA / 4000 VA -- -- --5 RECEPTACLE - BATHROOM 20 A 1 180 / 4000 2 40 A RECEPTACLE - STOVE 6,83 RECEPTACLE - BATHROOM 20 A 1 180 VA / 2500 VA -- -- --1 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 / 2500 2 30 A RECEPTACLE - DRYER 2,4CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 13Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P210TYPICAL FOR APARTMENTS 301, 401, AND 501.Notes:Total Est. Demand...96 AReceptacle 6100 VA 100.00% 6100 VATotal Conn. Current:101 APower 10600 VA 98.87% 10480 VATotal Est. Demand:20,003 VAOther 4279 VA 80.00% 3423 VATotal Conn. Load:20,979 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:104 A 97 ATotal Load:10934 VA 10044 VA29302728252623242122-- -- -- 1934 VA / 0 VA 2017,19 HP-2 (ROOF) 30 A 2 1934 / 01815 LIGHTING (AFCI) 15 A 1 110 VA / 0 VA -- -- ---- -- -- 4000 / 120 2 15 A FAN COILS 14,1611,13 RECEPTACLE - STOVE 40 A 2 4000 VA / 720 VA 1 15 A RECEPTACLES - BEDROOM (AFCI) 129 RECEPTACLES - KITCHEN (AFCI) 20 A 1 720 / 1000 1 20 A RECEPTACLE - MICROWAVE/VENT... 107 RECEPTACLES - HALL, LIV ROOM... 15 A 1 720 VA / 540 VA 1 20 A 8-- -- -- 1300 / 180 1 15 A RECEPTACLE - TELECOM (AFCI) 63,5 RECEPTACLE - DRYER 30 A 2 1300 VA / 720 VA 1 15 A RECEPTACLES - BEDROOM (AFCI) 41 RECEPTACLE - BATHROOM 20 A 1 180 / 15001 20 A RECEPTACLE - LAUNDRY (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 4Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P201TYPICAL FOR APARTMENTS 302, 322, 324, 402, 424, 425, 502, 523, AND 525.Notes:Total Est. Demand...75 AReceptacle 4840 VA 100.00% 4840 VATotal Conn. Current:76 APower 10600 VA 98.87% 10480 VATotal Est. Demand:15,591 VAOther 339 VA 80.00% 271 VATotal Conn. Load:15,779 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:76 A 76 ATotal Load:7899 VA 7880 VA2930272825262324212219201718-- -- -- 0 VA / 0 VA 1613,15 FAN COILS 15 A 2 60 / 99 1 15 A LIGHTING (AFCI) 1411 RECEPTACLE - FRIDGE, DINING RM... 20 A 1 360 VA / 4000 VA -- -- --9 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 / 4000 2 40 A RECEPTACLE - STOVE 10,127 RECEPTACLE - TELECOM (AFCI) 15 A 1 180 VA / 540 VA 1 20 A RECEPTACLES - KITCHEN (AFCI) 85 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 / 1300 -- -- --3 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 VA / 1300... 2 30 A RECEPTACLE - DRYER 4,61 RECEPTACLE - BATHROOM 20 A 1 180 / 720 1 15 A RECEPTACLES - BEDROOM (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:STUDIO 5Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P202TYPICAL FOR APARTMENTS 303, 323, 403, 424, 503, AND 524.Notes:Total Est. Demand...87 AReceptacle 5560 VA 100.00% 5560 VATotal Conn. Current:90 APower 10600 VA 98.87% 10480 VATotal Est. Demand:18,031 VAOther 2489 VA 80.00% 1991 VATotal Conn. Load:18,649 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:87 A 91 ATotal Load:9064 VA 9585 VA29302728252623242122192017 0 / 1165 -- -- ---- -- -- 0 VA / 1165 VA 2 15 A HP-1 (ROOF) 16,1813,15 FAN COILS 15 A 2 60 / 99 1 15 A LIGHTING (AFCI) 1411 RECEPTACLES - LIVING ROOM (AFCI) 15 A 1 540 VA / 4000 VA -- -- --9 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 / 4000 2 40 A RECEPTACLE - STOVE 10,127 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 VA / 540 VA 1 20 A RECEPTACLES - KITCHEN (AFCI) 85 RECEPTACLE - FRIDGE, KITCHEN... 20 A 1 540 / 1300 -- -- --3 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 VA / 1300... 2 30 A RECEPTACLE - DRYER 4,61 RECEPTACLE - BATHROOM 20 A 1 180 / 720 1 15 A RECEPTACLES - BEDROOM/HALL... 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:STUDIO 6Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P20312.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTIONPANEL SCHEDULESE505Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECTTYPICAL FOR APARTMENTS 318, 418, AND 518.Notes:Total Est. Demand...93 AReceptacle 5920 VA 100.00% 5920 VATotal Conn. Current:97 APower 10800 VA 98.52% 10640 VATotal Est. Demand:19,351 VAOther 3488 VA 80.00% 2791 VATotal Conn. Load:20,208 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:99 A 94 ATotal Load:10407 VA 9801 VA29302728252623242122-- -- -- 1487 VA / 0 VA 2017,19 HP-3 (ROOF) 20 A 2 1487 / 0 -- -- --15 20 A 1 154 VA / 180 VA 2 15 A FAN COILS 16,1813 RECEPTACLES - BEDROOM (AFCI) 15 A 1 900 / 5401 15 A RECEPTACLES - LIVING ROOM (AFCI) 14-- -- -- 4000 VA / 180 VA 1 15 A RECEPTACLE - TELECOM (AFCI) 129,11 RECEPTACLE - STOVE 40 A 2 4000 / 10001 20 A RECEPTACLE - MICROWAVE/VENT... 107 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 VA / 360 VA 1 20 A RECEPTACLES - KITCHEN (AFCI) 8-- -- -- 1400 / 720 1 15 A RECEPTACLES - BEDROOM (AFCI) 63,5 RECEPTACLE - DRYER 30 A 2 1400 VA / 1500... 1 20 A RECEPTACLE - LAUNDRY (AFCI) 41 RECEPTACLE - BATHROOM 20 A 1 180 / 180 1 20 A RECEPTACLE - BATHROOM 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 21Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P218ALSO TYPICAL FOR APARTMENT 320.Notes:Total Est. Demand...103 AReceptacle 8080 VA 100.00% 8080 VATotal Conn. Current:108 APower 10800 VA 98.52% 10640 VATotal Est. Demand:21,520 VAOther 3499 VA 80.00% 2800 VATotal Conn. Load:22,379 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:107 A 108 ATotal Load:11172 VA 11207 VA2930272825 0 / 0 -- -- --230 VA / 180 VA 2 15 A FAN COILS 24,26-- -- -- 1487 / 02219,21 HP-3 (ROOF) 20 A 2 1487 VA / 540 VA 1 15 A RECEPTACLES - LIVING ROOM (AFCI) 2017 20 A 1 165 / 360 1 15 A RECEPTACLES - HALL (AFCI) 1815 RECEPTACLES - LIVING ROOM (AFCI) 15 A 1 540 VA / 4000 VA -- -- --13 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 / 4000 2 40 A RECEPTACLE - STOVE 14,1611 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 VA / 720 VA 1 20 A RECEPTACLES - KITCHEN (AFCI) 129 RECEPTACLES - DINING ROOM... 20 A 1 540 / 360 1 20 A RECEPTACLE - FRIDGE, DINING RM... 107 RECEPTACLES - BEDROOM (AFCI) 15 A 1 720 VA / 900 VA 1 15 A RECEPTACLES - BEDROOM (AFCI) 85 RECEPTACLE - BATHROOM 20 A 1 180 / 180 1 20 A RECEPTACLE - BATHROOM 6-- -- -- 1400 VA / 180 VA 1 15 A RECEPTACLE - TELECOM (AFCI) 41,3 RECEPTACLE - DRYER 30 A 2 1400 / 1500 1 20 A RECEPTACLE - LAUNDRY (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 139Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P220ALSO TYPICAL FOR APARTMENT 321.Notes:Total Est. Demand...96 AReceptacle 6460 VA 100.00% 6460 VATotal Conn. Current:100 APower 10800 VA 98.52% 10640 VATotal Est. Demand:19,891 VAOther 3488 VA 80.00% 2791 VATotal Conn. Load:20,748 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:90 A 107 ATotal Load:9407 VA 11341 VA29302728252623242122-- -- -- 1487 VA / 0 VA 2017,19 HP-3 (ROOF) 20 A 2 1487 / 0 -- -- --15 LIGHTING (AFCI) 15 A 1 154 VA / 180 VA 2 15 A FAN COILS 16,1813 RECEPTACLE - TELECOM (AFCI) 15 A 1 180 / 1400 -- -- --11 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 VA / 1400... 2 30 A RECEPTACLE - DRYER 12,149 RECEPTACLE - BATHROOM 20 A 1 180 / 180 1 20 A RECEPTACLE - BATHROOM 107 RECEPTACLES - BEDROOM (AFCI) 15 A 1 720 VA / 900 VA 1 15 A RECEPTACLES - BEDROOM (AFCI) 85 RECEPTACLES - HALL, LIV ROOM... 15 A 1 720 / 4000 -- -- --3 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 VA / 4000... 2 40 A RECEPTACLE - STOVE 4,61 RECEPTACLES - ISLAND, DIN ROO... 20 A 1 720 / 540 1 20 A RECEPTACLES - KITCHEN (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 24Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P221ALSO TYPICAL FOR APARTMENT 224.Notes:Total Est. Demand...84 AReceptacle 4660 VA 100.00% 4660 VATotal Conn. Current:87 APower 10800 VA 98.52% 10640 VATotal Est. Demand:17,435 VAOther 2669 VA 80.00% 2135 VATotal Conn. Load:18,129 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:96 A 75 ATotal Load:10325 VA 7804 VA293027282526232421221920-- -- -- 0 / 01815,17 FAN COILS 15 A 2 60 VA / 1165 VA -- -- ---- -- -- 1400 / 1165 2 15 A HP-1 (ROOF) 14,1611,13 RECEPTACLE - DRYER 30 A 2 1400 VA / 180 VA 1 15 A RECEPTACLE - TELECOM (AFCI) 129 RECEPTACLE - FRIDGE, DINING RM... 20 A 1 360 / 1500 1 20 A RECEPTACLE - LAUNDRY (AFCI) 10-- -- -- 4000 VA / 360 VA 1 15 A RECEPTACLES - LIVING ROOM (AFCI) 85,7 RECEPTACLE - STOVE 40 A 2 4000 / 1000 1 20 A RECEPTACLE - MICROWAVE/VENT... 63 RECEPTACLES - KITCHEN (AFCI) 20 A 1540 VA / 99 VA 1 15 A LIGHTING (AFCI) 41 RECEPTACLE - BATHROOM 20 A 1 180 / 720 1 15 A RECEPTACLES - BEDROOM (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:STUDIO 25Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P222TYPICAL FOR APARTMENTS 225 AND 325.Notes:Total Est. Demand...84 AReceptacle 4840 VA 100.00% 4840 VATotal Conn. Current:87 APower 10800 VA 98.52% 10640 VATotal Est. Demand:17,471 VAOther 2489 VA 80.00% 1991 VATotal Conn. Load:18,129 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:87 A 87 ATotal Load:9065 VA 9064 VA2930272825262324212219201718-- -- -- 0 VA / 1165 VA -- -- --13,15 FAN COILS 15 A 2 60 / 1165 2 15 A HP-1 (ROOF) 14,1611 RECEPTACLE - LAUNDRY (AFCI) 20 A 11500 VA / 99 VA 1 15 A LIGHTING (AFCI) 12-- -- -- 4000 / 1400 -- -- --7,9 RECEPTACLE - STOVE 40 A 2 4000 VA / 1400... 2 30 A RECEPTACLE - DRYER 8,105 RECEPTACLES - LIVING ROOM (AFCI) 15 A 1 540 / 1000 1 20 A RECEPTACLE - MICROWAVE/VENT... 63 RECEPTACLE - FRIDGE, DINING RM... 20 A 1 360 VA / 540 VA 1 20 A RECEPTACLES - KITCHEN (AFCI) 41 RECEPTACLE - BATHROOM 20 A 1 180 / 720 1 15 A RECEPTACLES - BEDROOM (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:STUDIO 26Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P223TYPICAL OF UNITS 311, 411, AND 511.Notes:Total Est. Demand...87 AReceptacle 5380 VA 100.00% 5380 VATotal Conn. Current:91 APower 10800 VA 98.52% 10640 VATotal Est. Demand:18,155 VAOther 2669 VA 80.00% 2135 VATotal Conn. Load:18,849 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:89 A 92 ATotal Load:9244 VA 9605 VA293027282526232421221920-- -- -- 0 / 1165 -- -- --15,17 FAN COILS 15 A 2 60 VA / 1165 VA 2 15 A HP-1 (ROOF) 16,1813 RECEPTACLE - TELECOM (AFCI) 15 A 1 180 / 99 1 15 A LIGHTING (AFCI) 1411 RECEPTACLES - BEDROOM (AFCI) 15 A 1 900 VA / 540 VA 1 15 A RECEPTACLES - LIVING ROOM (AFCI) 129 RECEPTACLES - KITCHEN (AFCI) 20 A 1540 / 180 1 15 A RECEPTACLE - FRIDGE 107 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 VA / 540 VA 1 20 A RECEPTACLES - KITCHEN (AFCI) 8-- -- -- 1400 / 4000 -- -- --3,5 RECEPTACLE - DRYER 30 A 2 1400 VA / 4000... 2 40 A RECEPTACLE - STOVE 4,61 RECEPTACLE - BATHROOM 20 A 1 180 / 15001 20 A RECEPTACLE - LAUNDRY (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:STUDIO 14Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P211TYPICAL OF APARTMENTS 204, 214, 216, 304, 312, 314, 316, 404, 412, 414, 416, 504, 512, 514, AND 516.Notes:Total Est. Demand...89 AReceptacle 5740 VA 100.00% 5740 VATotal Conn. Current:92 APower 10800 VA 98.52% 10640 VATotal Est. Demand:18,515 VAOther 2669 VA 80.00% 2135 VATotal Conn. Load:19,209 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:103 A 78 ATotal Load:11045 VA 8164 VA29302728252623242122-- -- -- 1165 VA / 0 VA 2017,19 HP-1 (ROOF) 15 A 2 1165 / 01815 RECEPTACLE - FRIDGE 15 A 1 180 VA / 99 VA 1 15 A LIGHTING (AFCI) 16-- -- -- 0 / 720 1 15 A RECEPTACLES - LIVING ROOM (AFCI) 1411,13 FAN COILS 15 A 2 60 VA / 4000 VA -- -- --9 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 / 4000 2 40 A RECEPTACLE - STOVE 10,127 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 VA / 540 VA 1 20 A RECEPTACLES - KITCHEN (AFCI) 85 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 / 1400 -- -- --3 RECEPTACLE - TELECOM (AFCI) 15 A 1 180 VA / 1400 VA 2 30 A RECEPTACLE - DRYER 4,61 RECEPTACLES - BEDROOM (AFCI) 15 A 1 1080 / 180 1 20 A RECEPTACLE - BATHROOM 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:STUDIO 15Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P212TYPICAL FOR APARTMENTS 215, 217, 313, 315, 317, 413, 415, 417, 513, 515, AND 517.Notes:Total Est. Demand...88 AReceptacle 5560 VA 100.00% 5560 VATotal Conn. Current:91 APower 10800 VA 98.52% 10640 VATotal Est. Demand:18,335 VAOther 2669 VA 80.00% 2135 VATotal Conn. Load:19,029 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:87 A 95 ATotal Load:9004 VA 10025 VA29302728252623242122190 VA / 1165 VA -- -- --17 RECEPTACLE - TELECOM (AFCI) 15 A 1180 / 1165 2 15 A HP-1 (ROOF) 18,2015 RECEPTACLE - LAUNDRY (AFCI)20 A 1 1500 VA / 1400... -- -- ---- -- -- 0 / 1400 2 30 A RECEPTACLE - DRYER 14,1611,13 FAN COILS 15 A 2 60 VA / 0 VA 12-- -- -- 4000 / 99 1 15 A LIGHTING (AFCI) 107,9 RECEPTACLE - STOVE 40 A 2 4000 VA / 1000... 1 20 A RECEPTACLE - MICROWAVE/VENT... 85 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 / 540 1 20 A RECEPTACLES - KITCHEN (AFCI) 63 RECEPTACLES - LIVING ROOM (AFCI) 15 A 1 720 VA / 180 VA 1 15 A RECEPTACLE - FRIDGE 41 RECEPTACLE - BATHROOM 20 A 1 180 / 9001 15 A RECEPTACLES - BEDROOM (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:STUDIO 16Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P213ALSO TYPICAL FOR APARTMENTS 319.Notes:Total Est. Demand...92 AReceptacle 5020 VA 100.00% 5020 VATotal Conn. Current:97 APower 10800 VA 98.52% 10640 VATotal Est. Demand:19,092 VAOther 4290 VA 80.00% 3432 VATotal Conn. Load:20,110 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:97 A 96 ATotal Load:10155 VA 9954 VA29302728252623242122192017 0 / 1934 -- -- ---- -- -- 4000 VA / 1934... 2 30 A HP-2 (ROOF) 16,1813,15 RECEPTACLE - STOVE 40 A 2 4000 / 121 1 15 A LIGHTING (AFCI) 1411 RECEPTACLES - KITCHEN (AFCI) 20 A 1 360 VA / 1000 VA 1 20 A RECEPTACLE - MICROWAVE/VENT... 129 RECEPTACLES - BEDROOM (AFCI) 15 A 1 540 / 360 1 20 A RECEPTACLES - KITCHEN (AFCI) 107 RECEPTACLE - TELECOM (AFCI) 15 A 1 180 VA / 0 VA -- -- --5 RECEPTACLE - BATHROOM 20 A 1 180 / 120 2 15 A FAN COILS 6,83 RECEPTACLES - HALL (AFCI)15 A 1 1080 VA / 1400... -- -- --1 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 / 1400 2 30 A RECEPTACLE - DRYER 2,4CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:1 BR 22Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P21912.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTIONPANEL SCHEDULESE506Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECTTYPICAL FOR APARTMENTS 329 AND 429.Notes:Total Est. Demand...95 AReceptacle 6460 VA 100.00% 6460 VATotal Conn. Current:99 APower 10600 VA 98.87% 10480 VATotal Est. Demand:19,731 VAOther 3488 VA 80.00% 2791 VATotal Conn. Load:20,548 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:101 A 95 ATotal Load:10627 VA 9921 VA29302728252623242122-- -- -- 1487 VA / 0 VA 2017,19 HP-3 (ROOF) 20 A 2 1487 / 0 -- -- --15 LIGHTING (AFCI) 15 A 1 154 VA / 180 VA 2 15 A FAN COILS 16,1813 RECEPTACLE - BATHROOM 20 A 1 180 / 7201 15 A RECEPTACLES - BEDROOM (AFCI) 1411 RECEPTACLE - BATHROOM 20 A 1 180 VA / 900 VA1 15 A RECEPTACLES - BEDROOM/HALL... 12-- -- -- 1300 / 180 1 15 A RECEPTACLE - TELECOM (AFCI) 107,9 RECEPTACLE - DRYER 30 A 2 1300 VA / 720 VA 115 A RECEPTACLES - LIVING ROOM (AFCI) 85 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 / 4000 -- -- --3 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 VA / 4000... 2 40 A RECEPTACLE - STOVE 4,61 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 / 720 1 20 A RECEPTACLES - KITCHEN (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 32Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P229TYPICAL FOR APARTMENTS 330 AND 430.Notes:Total Est. Demand...92 AReceptacle 5920 VA 100.00% 5920 VATotal Conn. Current:95 APower 10600 VA 98.87% 10480 VATotal Est. Demand:19,038 VAOther 3297 VA 80.00% 2638 VATotal Conn. Load:19,817 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:103 A 85 ATotal Load:10987 VA 8830 VA29302728252623242122192017 0 / 1487 -- -- --15 LIGHTING (AFCI) 15 A 1 143 VA / 1487 VA 2 20 A HP-3 (ROOF) 16,1813 RECEPTACLE - BATHROOM 20 A 1 180 / 7201 15 A RECEPTACLES - BEDROOM (AFCI) 1411 RECEPTACLES - LIVING ROOM (AFCI) 15 A 1 540 VA / 180 VA 1 15 A RECEPTACLE - TELECOM (AFCI) 12-- -- -- 4000 / 540 1 20 A RECEPTACLES - KITCHEN (AFCI) 107,9 RECEPTACLE - STOVE 40 A 2 4000 VA / 1000... 1 20 A RECEPTACLE - MICROWAVE/VENT... 85 RECEPTACLES - BEDROOM (AFCI) 15 A 1 720 / 540 1 20 A RECEPTACLES - KITCHEN (AFCI) 63 RECEPTACLE - BATHROOM 20 A 1 180 VA / 1300 VA -- -- --1 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 / 1300 2 30 A RECEPTACLE - DRYER 2,4CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 33Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P230TYPICAL FOR APARTMENTS 321, 431, AND 531.Notes:Total Est. Demand...92 AReceptacle 5920 VA 100.00% 5920 VATotal Conn. Current:96 APower 10600 VA 98.87% 10480 VATotal Est. Demand:19,147 VAOther 3433 VA 80.00% 2747 VATotal Conn. Load:19,953 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:90 A 100 ATotal Load:9406 VA 10547 VA2930272825262324-- -- -- 1487 / 02219,21 HP-3 (ROOF) 20 A 2 1487 VA / 0 VA 20-- -- -- 0 / 180 1 15 A RECEPTACLE - TELECOM (AFCI) 1815,17 FAN COILS 15 A 2 180 VA / 0 VA 1613 RECEPTACLE - BATHROOM 20 A 1 180 / 99 1 15 A LIGHTING (AFCI) 14-- -- -- 4000 VA / 720 VA 1 15 A RECEPTACLES - BEDROOM (AFCI) 129,11 RECEPTACLE - STOVE 40 A 2 4000 / 720 115 A RECEPTACLES - LIVING ROOM (AFCI) 107 RECEPTACLES - KITCHEN (AFCI) 20 A 1 360 VA / 1000 VA 1 20 A RECEPTACLE - MICROWAVE/VENT... 85 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 / 1300 -- -- --3 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 VA / 1300... 2 30 A RECEPTACLE - DRYER 4,61 RECEPTACLE - BATHROOM 20 A 1 180 / 7201 15 A RECEPTACLES - BEDROOM (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 34Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P231TYPICAL FOR APARTMENTS 332, 432, AND 532.Notes:Total Est. Demand...98 AReceptacle 5380 VA 100.00% 5380 VATotal Conn. Current:104 APower 10600 VA 98.87% 10480 VATotal Est. Demand:20,374 VAOther 5643 VA 80.00% 4514 VATotal Conn. Load:21,623 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:103 A 105 ATotal Load:10671 VA 10952 VA2930272825262324-- -- -- 1487 / 02219,21 HP-3 (ROOF) 20 A 2 1487 VA / 0 VA 20-- -- -- 0 / 1165 -- -- --15,17 FAN COILS 15 A 2 60 VA / 1165 VA 2 15 A HP-1 (ROOF) 16,18-- -- -- 1300 / 99 1 15 A LIGHTING (AFCI) 1411,13 RECEPTACLE - DRYER 30 A 2 1300 VA / 1500... 1 20 A RECEPTACLE - LAUNDRY (AFCI) 12-- -- -- 4000 / 180 1 15 A RECEPTACLE - FRIDGE (AFCI) 107,9 RECEPTACLE - STOVE 40 A 2 4000 VA / 720 VA 115 A RECEPTACLES - LIVING ROOM (AFCI) 85 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 / 1000 1 20 A RECEPTACLE - MICROWAVE/VENT... 63 RECEPTACLE - TELECOM (AFCI) 15 A 1 180 VA / 540 VA 1 20 A RECEPTACLES - KITCHEN (AFCI) 41 RECEPTACLE - BATHROOM 20 A 1 180 / 720 1 15 A RECEPTACLES - BEDROOM (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:STUDIO 35Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P232TYPICAL FOR UNITS 333, 433, AND 533.Notes:Total Est. Demand...87 AReceptacle 5380 VA 100.00% 5380 VATotal Conn. Current:90 APower 10600 VA 98.87% 10480 VATotal Est. Demand:17,995 VAOther 2669 VA 80.00% 2135 VATotal Conn. Load:18,649 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:92 A 86 ATotal Load:9684 VA 8965 VA293027282526232421221920-- -- -- 1165 / 4000 -- -- --15,17 HP-1 (ROOF) 15 A 2 1165 VA / 4000... 2 40 A RECEPTACLE - STOVE 16,18-- -- -- 0 / 180 1 15 A RECEPTACLE - TELECOM (AFCI) 1411,13 FAN COILS 15 A 2 60 VA / 1000 VA 1 20 A RECEPTACLE - MICROWAVE/VENT... 129 RECEPTACLES - LIVING ROOM (AFCI)20 A 1 540 / 99 1 15 A LIGHTING (AFCI) 107 RECEPTACLE - FRIDGE, KITCHEN... 20 A 1 360 VA / 1300 VA -- -- --5 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 / 1300 2 30 A RECEPTACLE - DRYER 6,83 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 VA / 540 VA 1 20 A RECEPTACLES - KITCHEN (AFCI) 41 RECEPTACLES - BEDROOM (AFCI) 15 A 1 720 / 180 1 20 A RECEPTACLE - BATHROOM 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:STUDIO 36Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P233TYPICAL FOR APARTMENTS 334, 434, AND 534.Notes:Total Est. Demand...92 AReceptacle 5200 VA 100.00% 5200 VATotal Conn. Current:97 APower 10600 VA 98.87% 10480 VATotal Est. Demand:19,112 VAOther 4290 VA 80.00% 3432 VATotal Conn. Load:20,090 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:103 A 88 ATotal Load:10955 VA 9134 VA29302728252623242122192017 0 / 1934 -- -- ---- -- -- 0 VA / 1934 VA 2 30 A HP-2 (ROOF) 16,1813,15 FAN COILS 15 A 2 120 / 121 1 15 A LIGHTING (AFCI) 1411 RECEPTACLES - BEDROOM (AFCI) 15 A 1 540 VA / 180 VA 1 15 A RECEPTACLE - TELECOM (AFCI) 12-- -- -- 4000 / 540 1 20 A RECEPTACLES - KITCHEN (AFCI) 107,9 RECEPTACLE - STOVE 40 A 2 4000 VA / 1000... 1 20 A RECEPTACLE - MICROWAVE/VENT... 85 RECEPTACLES - HALL, LIV ROOM... 15 A 1 720 / 720 1 20 A RECEPTACLES - KITCHEN (AFCI) 6-- -- -- 1300 VA / 180 VA 1 20 A RECEPTACLE - BATHROOM 41,3 RECEPTACLE - DRYER 30 A 2 1300 / 1500 1 20 A RECEPTACLE - LAUNDRY (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:1 BR 37Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P234TYPICAL FOR APARTMENTS 326 AND 426.Notes:Total Est. Demand...79 AReceptacle 5560 VA 100.00% 5560 VATotal Conn. Current:80 APower 10600 VA 98.87% 10480 VATotal Est. Demand:16,368 VAOther 410 VA 80.00% 328 VATotal Conn. Load:16,570 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:76 A 83 ATotal Load:7860 VA 8710 VA2930272825262324212219201718-- -- -- 0 VA / 180 VA 1 15 A RECEPTACLE - TELECOM (AFCI) 1613,15 FAN COILS 15 A 2 120 / 01411 RECEPTACLES - BEDROOM (AFCI) 15 A 1 1080 VA / 110 VA 1 20 A 129 RECEPTACLES - LIVING ROOM (AFCI) 15 A 1 720 / 180 1 20 A RECEPTACLE - BATHROOM 107 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 VA / 1300... -- -- ---- -- -- 4000 / 1300 2 30 A RECEPTACLE - DRYER 6,83,5 RECEPTACLE - STOVE 40 A 2 4000 VA / 540 VA 1 20 A RECEPTACLES - KITCHEN (AFCI) 41 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 / 1000 1 20 A RECEPTACLES - KITCHEN (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:1 BR 29Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P226TYPICAL FOR APARTMENTS 327 AND 427.Notes:Total Est. Demand...91 AReceptacle 5920 VA 100.00% 5920 VATotal Conn. Current:95 APower 10600 VA 98.87% 10480 VATotal Est. Demand:19,020 VAOther 3275 VA 80.00% 2620 VATotal Conn. Load:19,795 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:93 A 97 ATotal Load:9668 VA 10127 VA293027282526232421221920-- -- -- 0 / 1487 -- -- --15,17 FAN COILS 15 A 2 180 VA / 1487 VA 2 20 A HP-3 (ROOF) 16,1813 RECEPTACLES - BEDROOM (AFCI) 20 A 1 180 / 121 1 15 A LIGHTING (AFCI) 1411 RECEPTACLES - BEDROOM (AFCI) 15 A 1 540 VA / 720 VA 1 15 A RECEPTACLES - BEDROOM (AFCI) 129 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 / 1300 -- -- --7 RECEPTACLES - LIVING ROOM (AFCI) 15 A 1 900 VA / 1300 VA 2 30 A RECEPTACLE - DRYER 8,10-- -- -- 4000 / 360 1 20 A RECEPTACLES - KITCHEN (AFCI) 63,5 RECEPTACLE - STOVE 40 A 2 4000 VA / 1000... 1 20 A RECEPTACLE - MICROWAVE/VENT... 41 RECEPTACLE - BATHROOM 20 A 1 180 / 540 120 A RECEPTACLES - KITCHEN (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 30Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P227TYPICAL FOR APARTMENTS 328 AND 428.Notes:Total Est. Demand...94 AReceptacle 6280 VA 100.00% 6280 VATotal Conn. Current:98 APower 10600 VA 98.87% 10480 VATotal Est. Demand:19,568 VAOther 3510 VA 80.00% 2808 VATotal Conn. Load:20,390 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:104 A 90 ATotal Load:10983 VA 9407 VA2930272825262324-- -- -- 1487 / 02219,21 HP-3 (ROOF) 20 A 2 1487 VA / 0 VA 20-- -- -- 0 / 180 1 15 A RECEPTACLE - TELECOM (AFCI) 1815,17 FAN COILS 15 A 2 180 VA / 0 VA 1613 RECEPTACLE - BATHROOM 20 A 1 180 / 176 1 15 A LIGHTING (AFCI) 14-- -- -- 4000 VA / 720 VA 1 15 A RECEPTACLES - BEDROOM (AFCI) 129,11 RECEPTACLE - STOVE 40 A 2 4000 / 720 1 20 A 107 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 VA / 1000 VA 1 20 A RECEPTACLE - MICROWAVE/VENT... 85 RECEPTACLES - HALL, LIV ROOM... 15 A 1 720 / 720 1 15 A RECEPTACLES - BEDROOM (AFCI) 63 RECEPTACLE - BATHROOM 20 A 1 180 VA / 1300 VA -- -- --1 Receptacle 20 A 1 1500 / 1300 2 30 A RECEPTACLE - DRYER 2,4CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 31Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P22812.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET ERIC COLBERT & ASSOCIATESDRAWING TITLESCALE:THESE DRAWINGS ARE INSTRUMENTS OF SERVICE PREPARED BY THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT THERETO.SHEET NO.COPYRIGHT: 2019 ERIC COLBERT & ASSOCIATES ©STAMP717 5TH STREET NW WASHINGTON, DC 20001JOB NO.DATE DESCRIPTIONPANEL SCHEDULESE507Taitem Engineering, PC110 S. Albany StreetIthaca, NY 14850T.G. MILLER, P.C.605 West State Street, Suite AIthaca, NY 14850Trowbridge Wolf Michaels Landscape ArchitectsLLP1001 West Seneca Street, Suite 201Ithaca, NY 14850ARNOT ITHACA 2,LLC230 Colonial DriveHorseheads, New York 14845430-444 WestState / MLK StreetITHACA, NEW YORKECA # 725MEP & STRUCTURALCIVILLANDSCAPE ARCHITECTNotes:Total Est. Demand...88 AReceptacle 5560 VA 100.00% 5560 VATotal Conn. Current:91 APower 10600 VA 98.87% 10480 VATotal Est. Demand:18,224 VAOther 2730 VA 80.00% 2184 VATotal Conn. Load:18,890 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:89 A 93 ATotal Load:9205 VA 9685 VA29302728252623242122192017 RECEPTACLE BALCONY 20 A 1 180 / 1165 -- -- ---- -- -- 0 VA / 1165 VA 2 15 A HP-1 (ROOF) 16,1813,15 FAN COILS 15 A 2 120 / 100 1 15 A LIGHTING (AFCI) 14-- -- -- 1300 VA / 180 VA 1 15 A RECEPTACLE - TELECOM (AFCI) 129,11 RECEPTACLE - DRYER 30 A 2 1300 / 7201 15 A RECEPTACLES - BEDROOM (AFCI) 10-- -- -- 4000 VA / 1500... 1 20 A RECEPTACLE - LAUNDRY (AFCI) 85,7 RECEPTACLE - STOVE 40 A 2 4000 / 180 1 20 A RECEPTACLE - BATHROOM 63 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 VA / 1000 VA 1 20 A RECEPTACLE - MICROWAVE/VENT... 41 RECEPTACLES - LIVING ROOM (AFCI) 15 A 1 900 / 540 1 20 A RECEPTACLES - KITCHEN (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:1 BR 128Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P530ALSO TYPICAL FOR APARTMENT 522.Notes:Total Est. Demand...96 AReceptacle 6100 VA 100.00% 6100 VATotal Conn. Current:101 APower 10600 VA 98.87% 10480 VATotal Est. Demand:20,021 VAOther 4302 VA 80.00% 3441 VATotal Conn. Load:21,002 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:100 A 101 ATotal Load:10427 VA 10574 VA29302728252623242122190 VA / 1934 VA -- -- --17 LIGHTING (AFCI) 15 A 1 133 / 1934 2 30 A HP-2 (ROOF) 18,2015 RECEPTACLE - PATIO 15 A 1 180 VA / 0 VA -- -- --13 RECEPTACLE - TELECOM (AFCI) 15 A 1 180 / 120 2 15 A FAN COILS 14,1611 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 VA / 4000... -- -- --9 RECEPTACLE - BATHROOM 20 A 1 180 / 4000 2 40 A RECEPTACLE - STOVE 10,127 RECEPTACLES - BEDROOM (AFCI) 15 A 1 720 VA / 1300 VA -- -- --5 RECEPTACLE - LAUNDRY (AFCI) 20 A 1 1500 / 1300 2 30 A RECEPTACLE - DRYER 6,83 RECEPTACLES - KITCHEN (AFCI) 20 A 1 360 VA / 1080 VA 1 15 A RECEPTACLES - HALL, LIV ROOM... 41 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 / 540 1 20 A RECEPTACLES - KITCHEN (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:1 BR 91Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P422Notes:Total Est. Demand...83 AReceptacle 6460 VA 100.00% 6460 VATotal Conn. Current:84 APower 10600 VA 98.87% 10480 VATotal Est. Demand:17,226 VAOther 357 VA 80.00% 286 VATotal Conn. Load:17,417 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total...81 A 86 A 86 ATotal Load:8457 VA 8960 VA 8960 VA293027282526232421221920-- -- -- 0 VA / 0 VA 1 15 A LIGHTING (AFCI) 1815,17 FAN COILS 15 A 2 180 VA / 4000... -- -- --13 RECEPTACLE - MICROWAVE/VEN... 20 A 1 1000 / 4000 2 40 A RECEPTACLE - STOVE 14,1611 RECEPTACLE - PATIO 15 A 1 0 VA / 0 VA1 20 A RECEPTACLES - KITCHEN (AFCI) 129 RECEPTACLES - BEDROOM (AFCI) 15 A 1 0 VA / 0 VA 1 15 A RECEPTACLES - HALL, LIV ROOM... 107 RECEPTACLE - BATHROOM 20 A 1 0 / 0 1 15 A RECEPTACLES - BEDROOM (AFCI) 8-- -- -- 0 VA / 0 VA 1 20 A RECEPTACLE - BATHROOM 63,5 RECEPTACLE - DRYER 30 A 2 1300 VA / 150... 1 20 A RECEPTACLE - LAUNDRY (AFCI) 41 RECEPTACLES - KITCHEN (AFCI) 20 A 1 360 / 360 1 20 A RECEPTACLES - KITCHEN (AFCI) 2CKT Circuit Description Trip PolesABCPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 127Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P527ALSO TYPICAL FOR APARTMENT 520.Notes:Total Est. Demand...98 AReceptacle 7180 VA 100.00% 7180 VATotal Conn. Current:102 APower 10600 VA 98.87% 10480 VATotal Est. Demand:20,469 VAOther 3511 VA 80.00% 2809 VATotal Conn. Load:21,291 VALighting 0 VA 0.00% 0 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:103 A 101 ATotal Load:10744 VA 10547 VA293027282526232421 0 / 1487 -- -- ---- -- -- 0 VA / 1487 VA 2 20 A HP-3 (ROOF) 20,2217,19 FAN COILS 15 A 2 180 / 177 1 15 A LIGHTING (AFCI) 1815 RECEPTACLE - PATIO 15 A 1 180 VA / 180 VA 1 15 A RECEPTACLE - TELECOM (AFCI) 1613 RECEPTACLES - BEDROOM (AFCI) 15 A 1 1080 / 180 1 20 A RECEPTACLE - BATHROOM 1411 RECEPTACLE - LAUNDRY (AFCI)20 A 1 1500 VA / 1300... -- -- --9 RECEPTACLES - HALL, LIV ROOM... 15 A 1 720 / 1300 2 30 A RECEPTACLE - DRYER 10,127 RECEPTACLE - MICROWAVE/VENT... 20 A 1 1000 VA / 4000... -- -- --5 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 / 4000 2 40 A RECEPTACLE - STOVE 6,83 RECEPTACLES - KITCHEN (AFCI) 20 A 1 540 VA / 360 VA 1 20 A RECEPTACLES - KITCHEN (AFCI) 41 RECEPTACLE - BATHROOM 20 A 1 180 / 900 115 A RECEPTACLES - BEDROOM (AFCI) 2CKT Circuit Description Trip PolesABPoles Trip Circuit Description CKTNotes:Enclosure:Type 1Mounting:FlushWires:3Mains Rating:125 ASupply From: Phases:1Mains Type:MLOLocation:2 BR 90Volts:120/208 SingleA.I.C. Rating:10Branch Panel: P42012.23.2020 PERMIT SET1 03.11.2021 100% CONSTRUCTION DOCUMENT SET