HomeMy WebLinkAbout327 W.SENECA_PLUMBING PLANS_2020.07.01T H DIRECTION OF FLOW PIPE CAP OR PLUG PIPING UP PIPING DOWN THERMOSTAT HUMIDISTAT DOMESTIC COLD WATER (CW) DOMESTIC HOT WATER (HW) HOT WATER CIRCULATING (HWC) WASTE HOSE BIBB / WALL HYDRANT BACKFLOW PREVENTER FLOOR DRAIN VENT THROUGH ROOF (VTR) WATER METERM NOT ALL SYMBOLS LISTED BELOW ARE USED ON THIS SET OF DRAWINGS SYMBOL DESCRIPTION PLUMBING LEGEND CW CW HW HW SAN SAN GYPSUM BOARD PIPE THRU WALL PROFORM QUICK-SET FS-90 COMPOUND INSULATION PER SECTIONS WOOD STUD EXTERIOR SIDING SLOPE Ø1-1/2" FLOOR DRAIN SHOWER VALVE SHOWER HEAD WASTE PIPE Ø1-1/2" P-TRAP Ø1-1/2" Ø3/8" CW & HW FINISH FLOOR LEVEL TUB VALVE 3/4" COMBINATION HW CW PANELARRESTOR HAMMER LINE 42" WASTE WALL BOX CLOTHES WASHER SWEAT CONNECTION FLOOR 1/2" 1/2" SWEAT CONNECTION 3/4" COMBINATION WATER ACCESS 2" PROJECT NO.PROJECT:TITLE OF DRAWINGDRAWING NO. FIRST ISSUE DATE:0ISSUED/REVISIONS:DATE:123456ENGINEER:OWNER/DEVELOPER:112 N. MAIN ST.HORSEHEADS, NY 14845607-377-7990 | WWW.MASER-AE.COM119 S. CAYUGA STREETITHACA, NY 14850327 W. SENECA ST.ITHACA, NEW YORK 14850327 W. SENECA STREETA 5 4 3 2 16 B C D E A B C D E 78 5 4 3 2 1678 ISSUED FOR PERMIT08/19/2019REVISED FOR MECH. RM. EQUIP.06/04/20203-STORY, 12-UNIT APARTMENT BUILDINGREVISED FOR CONSTRUCTION06/17/2020DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT,ENGINEER, SURVEYOR OR LANDSCAPEARCHITECT TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THISDOCUMENT IS REQUIRED BY LAW TOAFFIX THEIR SEAL AND THE NOTATION,"ALTERED BY," FOLLOWED BY THEIRSIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.#VISUMDEVELOPMENT GROUPMAY 31, 2019 2019-008 A.GENERAL NOTES: 1.CONFORM TO ALL GENERAL AND SPECIAL CONDITIONS OF CONTRACT AS SPECIFIED BY SITE ENGINEER'S AND/OR OWNER. 2.VISIT SITE, CHECK FACILITIES AND CONDITIONS AND MAKE ALL NECESSARY OBSERVATIONS AND MEASUREMENTS. NOTE CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED AND TAKE ALL ITEMS INTO CONSIDERATION IN BID. 3.SYSTEMS ARE TO BE COMPLETE AND WORKABLE IN ALL RESPECTS, PLACED IN OPERATION AND PROPERLY ADJUSTED. 4.CONTRACTOR SHALL PROVIDE THEIR OWN CLEAN-UP, REMOVAL AND LEGAL DISPOSAL OF ALL RUBBISH DAILY. 5.CONTRACTOR SHALL PROTECT THEIR WORK, THEIR EXISTING AND ADJACENT PROPERTY AGAINST WEATHER. 6.CONTRACTOR SHALL PROTECT THEIR WORK, MATERIALS, APPARATUS AND FIXTURES FROM ANY WORK DAMAGED BY FAILURE TO PROVIDE PROTECTION REQUIRED, SHALL BE REMOVED AND REPLACED WITH NEW MATERIAL AT THE CONTRACTOR'S EXPENSE. 7.ARRANGE FOR AND OBTAIN OWNER'S AND INSURANCE REPRESENTATIVE'S PERMISSION FOR ANY SERVICE SHUTDOWNS. 8.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, SEQUENCES OF CONSTRUCTION AND THE SAFETY OR WORKMEN. 9.NO PIPING, DUCTWORK, WIRING, ETC. SHALL BE INSTALLED OR ROUTED ABOVE ELECTRICAL PANELS AND EQUIPMENT. B.CODES, PERMITS, STANDARDS AND REGULATIONS: 1.CONFORM TO ALL APPLICABLE CODES (LOCAL, STATE, NATIONAL CODES, NFPA, OSHA, ETC.). GOVERNMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS, AND APPLICABLE STANDARDS. 2.OBTAIN PERMITS AND PAY ALL FEES, ARRANGE FOR ALL REQUIRED INSPECTIONS AND APPROVALS. C.DRAWINGS: 1.THE SYSTEM AS SHOWN ON PLUMBING DRAWINGS ARE DIAGRAMMATIC. CONFIRM ALL DIMENSIONS BY FIELD MEASUREMENT. 2.THE EXACT LOCATIONS FOR FIXTURES, EQUIPMENT AND PIPING WHICH IS NOT COVERED BY DRAWINGS, SHALL BE OBTAINED FROM THE SITE ENGINEER'S OR THEIR REPRESENTATIVE IN THE FIELD AND THE WORK SHALL BE LAID OUT ACCORDINGLY. D.BASE EQUIPMENT, MATERIALS AND SUBSTITUTIONS: 1.ALL EQUIPMENT AND MATERIALS SHALL BE NEW, FREE OF DEFECTS AND U.L. LABELED. 2.BASE BID MANUFACTURERS ARE INCLUDED IN THE SPECIFICATIONS OR LISTED IN THE NAME OR MAKE OF ANY ARTICLE, DEVICE, MATERIAL, FORM OF CONSTRUCTION, FIXTURE, ETC. STATED IN THIS SPECIFICATIONS, WHETHER OR NOT THE WORDS "OR APPROVED EQUAL" ARE USED, SHALL BE KNOWN AS A "STANDARD". 3.ALL PROPOSALS SHALL BE BASED ON "STANDARDS" SPECIFIED. 4.THE EQUIPMENT SCHEDULES ON THE DRAWINGS INDICATE MANUFACTURERS EQUIPMENT MODEL NUMBERS THAT THIS DESIGN HAS BEEN BASED ON. THE USE OF OTHER MANUFACTURERS EQUIPMENT THAT IS LISTED AS ACCEPTABLE ALTERNATES AND REFLECTS ANY ADDITIONAL COST OF SUCH CHANGES SHALL BE PAID BY THE CONTRACTOR. 5.SUBSTITUTIONS ARE SUBJECT TO THE APPROVAL OF THE OWNER. IF A SUBSTITUTION IS SUBMITTED, IT IS THE CONTRACTOR'S RESPONSIBILITY TO EVALUATE IT AND CERTIFY THAT THE SUBSTITUTION IS EQUIVALENT IN ALL RESPECTS TO THE BASE SPECIFICATIONS. 6.COORDINATE ALL APPROVED SUBSTITUTIONS. ANY COSTS RESULTING FROM SUBSTITUTION SHALL BE THE RESPONSIBILITY OF ANY PAID FOR BY THE CONTRACTOR. APPROVED SHOP DRAWINGS DO NOT ABSOLVE THIS CONTRACTOR FROM THIS RESPONSIBILITY. E.WARRANTY: 1.FULLY WARRANT ALL MATERIALS, EQUIPMENT AND WORKMANSHIP FOR (1) YEAR FROM DATE OF ACCEPTANCE. 2.EXTEND ALL MANUFACTURERS' WARRANTIES TO OWNER. 3.REPAIR OR REPLACE WITHOUT CHARGE TO THE OWNER ALL ITEMS FOUND DEFECTIVE DURING THE WARRANTY PERIOD. IN THE CASE OF REPLACEMENT OR REPAIR DUE TO FAILURE WITHIN THE WARRANTY PERIOD, THE WARRANTY ON THAT PORTION OF THE WORK SHALL BE EXTENDED FOR A MINIMUM PERIOD OF ONE (1) YEAR FROM THE DATE OF SUCH REPLACEMENT OR REPAIR. F.INSULATION: 1.PLUMBING INSULATION (AS MANUFACTURED BY OWENS CORNING, KNAUF, SCHULLER OR CERTAINTEED) 2.INSULATE ALL ABOVE GRADE HOT AND COLD WATER PIPING WITH MOLDED FIBER GLASS HAVING AN ALL SERVICE JACKET. 3.INSULATION THICKNESS SCHEDULE: 1) LESS THAN 2" DIAMETER PIPE: 1" THICK-HW AND 1/2" THICK CW; 2) 2"-8" DIAMETER PIPE: 1-1/2" THICK. G.PIPING AND VALVES: 1.LABEL ALL PIPING AND SHOW DIRECTION OF FLOW EVERY 20 FEET ON CENTER. 2.CONNECTIONS TO EQUIPMENT: 2.1.PROVIDE VALVED WATER AND/OR GAS CONNECTION FOR EQUIPMENT. 2.2.INCLUDE ACCESSORIES REQUIRED BY CODE, DRAWING OR MANUFACTURER'S INSTRUCTIONS. 3.FLUSH, VENT AND SANITIZE ALL WATER PIPING WITH CHLORINE AS REQUIRED PER AWWA, LOCAL BUILDING DEPARTMENT AND HEALTH DEPARTMENT CODES. 4.DOMESTIC HOT AND COLD WATER PIPING UNDER CONCRETE FLOOR TO BE COVERED WITH SAND SO THAT PIPING WILL NOT BECOME EMBEDDED IN THE FLOOR SLAB. 5.ALL PIPING UNDER CONCRETE FLOOR SHALL BE PEX, CONTINUOUS. NO SPLICES OR FITTINGS WILL BE ALLOWED. PROVIDE CPVC CONDUITS FOR ALL UNDERSLAB PIPING. 6.EXTREME CAUTION MUST BE TAKEN SO THAT NO COPPER PIPING AND INSULATION UNDER CONCRETE FLOORS BECOMES CRUSHED, CUT, SPLIT OR DEFORMED DURING THE POURING OF THE FLOOR SLAB. 7.ALL PIPING UNDER CONCRETE FLOORS SHALL BE COVERED INSIDE A PVC PIPE. G.PLUMBING INSTRUMENTS AND CONTROLS: 1.AFTER INSTALLATION, CHECK ALL EQUIPMENT AND PERFORM START UP IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 2.ALL PIPING SHALL BE TESTED AND FREE OF LEAKS AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 3.WORK THAT IS SCHEDULED TO BE CONCEALED OR INSULATED SHALL REMAIN UNCOVERED UNTIL REQUIRED TESTS HAVE BEEN COMPLETED. IF THE CONSTRUCTION SCHEDULE REQUIRES, ARRANGE FOR TESTS ON SECTIONS AT A TIME. 4.BALANCE ALL SYSTEMS, CALIBRATE CONTROLS, CHECK FOR PROPER OPERATION AND SEQUENCE UNDER ALL CONDITIONS AND MAKE ALL NECESSARY ADJUSTMENTS. 5.INSTRUCT OWNER IN OPERATION OF SYSTEMS AND SUBMIT OPERATING AND MAINTENANCE MANUAL FOR ALL EQUIPMENT AND SYSTEMS. TYP. THRU WALL PIPING DETAIL SCALE: 3" = 1'-0"1 TYP. SHOWER/TUB PLUMBING DETAIL SCALE: 1" = 1'-0"2 TYP. WASHER WALL BOX PLUMBING DETAIL SCALE: 3/4" = 1'-0"3 TYP. UNIT PLUMBING FIXTURE SCHEDULE: 1.DW = DISHWASHER 1.1.1/2" Ø HW 1.2.1-1/2" Ø WASTE 2.SINKS 2.1.3/8" Ø CW 2.2.3/8" Ø HW 2.3.1-1/2" Ø WASTE 3.WH = WATER HEATER 3.1.3/4" Ø CW 3.2.3/4" Ø HW 4.TOILET 4.1.3/8" Ø CW 4.2.3" Ø WASTE 5.TUB = BATH TUB 5.1.3/8" Ø CW 5.2.3/8" Ø HW 5.3.1-1/2" Ø WASTE 6.WD = WASHER/DRYER 6.1.1/2" Ø CW 6.2.1/2" Ø HW 6.3.2" WASTE PLUMBING - NOTES, LEGEND & DETAILSP001 & ABBREV AC ANSI ASTM ATM BL BLDG. B.O.P °C Cm DC DN D.O.L DR DWGS °F FD FM FP FPM FS FT GPM HP Hz JP kG kW LB m MAX MIN mm NC NFPA NO NO. N.P.T NRS PIV PS RN TYP AND ABBREVIATION ALTERNATING CURRENT AMERICAN NATIONAL STANDARD INSTITUTE AMERICAN SOCIETY FOR TESTING METERIAL ATMOSPHERE BRANCH LINE BUILDING BOTTOM OF PIPE DEGREE CELSIUS CENTIMETRE DIRECT CURRENT DROP NIPPLE DIRECT ON-LINE STARTER DRAIN DRAWINGS DEGREE FAHRENHEIT FLOOR DRAIN FACTORY MUTUAL FIRE PUMP FEET PER MINUTE FLOW SWITCH FEET GALLON PER MINUTE HORSE POWER HERTZ JOCKEY PUMP KILOGRAM KILOWATT POUND METRE MAXIMUM MINIMUM MILIMETRE NORMALLY CLOSED NATIONAL FIRE PROTECTION ASSOCIATION NORMALLY OPEN NUMBER NATIONAL PIPE TREAD NON RISING STEM VALVE POST INDICATOR VALVE PRESSURE SWITCH RISER NIPPLE TYPICAL GENERAL VALVE GATE VALVE (NON-RISING STEM) OS & Y GATE VALVE ANGLE VALVE CHECK VALVE BUTTERFLY VALVE SOLENOID VALVE HYDRAULIC CONTROL VALVE S HCV PRV PRESSURE REGULATING VALVE (PILOT OPERATED) PRESSURE RELIEF VALVE (PILOT OPERATED) SIGHT FLOW INDICATOR EQUIPMENT DRAIN OPEN WASTE CONE CLOSED WASTE CONE FOOT VALVE AUTOMATIC AIR VENT WITH VALVE POST INDICATOR VALVE SELF OPERATED PRESSURE REGULATING VALVE SELF OPERATED BACK PRESSURE REGULATING VALVE PILOT OPERATED PRESSURE REGULATING VALVE PILOT OPERATED BACK PRESSURE REGULATING VALVE DR DRAIN VALVE KEY OPERATED VALVE VALVE IN PIT FLOW METERING ELEMENT FS FS - FLOW SWITCH, PS - PRESSURE SWITCH PRESSURE GAUGE WITH COCK AND SNUBBER AIR ELEMINATOR, AUTOMATIC WITH VALVE FLOOR DRAINFD ALIGNMENT GUIDE SLEEVE EXPANSION JOINT PUMP PITCH OF DRAINPD FLOW IN DIRECTION OF ARROW M D F DRAIN PIPE FIRE PROTECTION PIPE ELBOW 90° ELBOW LOOKING UP ELBOW LOOKING DOWN TEE TEE LOOKING UP TEE LOOKING DOWN FLANGE UNION REDUCER REDUCER CONCENTRIC REDUCER ECCENTRIC STRAIGHT INVERT REDUCER ECCENTRIC STRAIGHT CROWN ELBOW 45° ELBOW REDUCER ELBOW LONG RADIUS LATERAL REMOVABLE CAP END BLIND FLANGED END FIRE HYDRANT ROOF MANIFOLD HOSE REEL CABINET, SURFACE MOUNT HOSE REEL CABINET, SEMI-RECESSED MOUNT HOSE REEL CABINET, RECESSED MOUNT ALARM VALVE (LOOKING DOWN) WATER MOTOR GONG SIDE WALL PENDENT SPRINKLER HEAD CO PORTABLE EXTINGUISHER AUTOMATIC BCF (HALON 1211) EXTINGUISHER FIRE PROTECTION SYSTEM LEGEND LETTER SYMBOLS VALVE & PIPING SYMBOLS FITTING SYMBOLS SYMBOLS DESCRIPTIONSYMBOLSDESCRIPTIONSYMBOLSDESCRIPTION SYMBOLS DESCRIPTION FH FHC FHC FHC FIRE DEPARTMENT CONNECTION ALARM VALVE WITH WATER MOTOR GONG PENDENT SPRINKLER HEAD, RECESSED TYPE DRY CHEMICAL EXTINGUISHER HYDRANT HOSE CABINET UP-RIGHT SPRINKLER HEAD HHC FDC FIRE PROTECTION SYMBOLS PROJECT NO.PROJECT:TITLE OF DRAWINGDRAWING NO. FIRST ISSUE DATE:0ISSUED/REVISIONS:DATE:123456ENGINEER:OWNER/DEVELOPER:112 N. MAIN ST.HORSEHEADS, NY 14845607-377-7990 | WWW.MASER-AE.COM119 S. CAYUGA STREETITHACA, NY 14850327 W. SENECA ST.ITHACA, NEW YORK 14850327 W. SENECA STREETA 5 4 3 2 16 B C D E A B C D E 78 5 4 3 2 1678 ISSUED FOR PERMIT08/19/2019REVISED FOR MECH. RM. EQUIP.06/04/20203-STORY, 12-UNIT APARTMENT BUILDINGREVISED FOR CONSTRUCTION06/17/2020DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT,ENGINEER, SURVEYOR OR LANDSCAPEARCHITECT TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THISDOCUMENT IS REQUIRED BY LAW TOAFFIX THEIR SEAL AND THE NOTATION,"ALTERED BY," FOLLOWED BY THEIRSIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.#VISUMDEVELOPMENT GROUPMAY 31, 2019 2019-008 A.FIRE PROTECTION NOTES: 1.THE FIRE PROTECTION SYSTEM ENGINEERING DRAWINGS, SPECIFICATIONS, PRESCRIPTIVE AND PERFORMANCE CRITERIA, WATER SUPPLY ANALYSIS AND OTHER MATERIALS OR REPRESENTATIONS, WHICH ARE SUBMITTED WITH THE GENERAL CONSTRUCTION DOCUMENTS THAT SET FORTH THE OVERALL DESIGN REQUIREMENTS AND PROVIDE SUFFICIENT DIRECTION FOR THE CONTRACTOR TO LAY OUT THE CONSTRUCTION, ALTERATION, DEMOLITION, RENOVATION, REPAIR, MODIFICATION, PERMITTING AND SUCH, FOR ANY PUBLIC OR PRIVATE FIRE PROTECTION SYSTEM(S), WHICH ARE PREPARED, SIGNED, DATED AND SEALED BY THE ENGINEER OF RECORD FOR THE FIRE PROTECTION SYSTEM(S). 2.THE CONTRACTOR SHALL PROVIDE: LAYOUT DRAWINGS, HYDRAULIC CALCULATIONS, CATALOG INFORMATION ON STANDARD PRODUCTS, AND OTHER CONSTRUCTION DATA PREPARED BY THE LICENSED CONTRACTOR THAT PROVIDES DETAIL ON THE LOCATION OF RISERS, CROSS MAINS, BRANCH LINES, SPRINKLER HEADS, SIZING OF PIPE, HANGER LOCATIONS, AND HYDRAULIC CALCULATIONS AND ALSO SERVES AS A GUIDE FOR FABRICATION AND INSTALLATION OF A FIRE PROTECTION SYSTEM. FIRE PROTECTION SYSTEM LAYOUT DOCUMENTS ARE BASED UPON ENGINEERING DIRECTION PROVIDED IN THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS AND REQUIRE NO ADDITIONAL ENGINEERING INPUT. THESE SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW. SHOP DRAWINGS STAMPED APPROVED OR FURNISH AS CORRECTED SHALL THEN BE SUBMITTED BY THE CONTRACTOR TO THE BUILDING DEPARTMENT AHJ FOR APPROVAL. 3.HANGER LOCATIONS SHALL BE COORDINATED WITH THE BUILDING STRUCTURE. SUPPORT PIPING IN ACCORDANCE WITH NFPA-13, PROVIDE ALL MISCELLANEOUS STEEL FRAMING AS REQUIRED TO SUPPORT PIPING FROM STRUCTURE. HANGERS AND ROD SHALL HAVE A GALVANIZED OR PLATED FINISH. 4.PROVIDE CHROME ESCUTCHEONS WHERE PIPING PENETRATES WALLS IN EXPOSED AREAS. 5.SPRINKLER HEADS SHALL BE AS FOLLOWS: 5.1.HEADS MOUNTED IN CEILINGS SHALL BE SEMI-RECESSED TYPE, QUICK RESPONSE, FACTORY CHROME PLATED. 5.2.HEADS IN AREAS WITHOUT CEILINGS SHALL BE UPRIGHT, BRASS FINISH, QUICK RESPONSE TYPE. 5.3.HEAD MOUNTED IN ELECTRICAL ROOM SHALL BE SIDEWALL HEAD TYPE, QUICK RESPONSE TYPE. 6.TIE-IN OF FLOW SWITCH AND TAMPER SWITCHES TO FIRE ALARM SYSTEM, AND WIRING SHALL BE PERFORMED UNDER DIVISION 26. 7.ALL SPRINKLER PIPING SHALL BE PAINTED WHERE INSTALLED BELOW CEILINGS, AND SIMILAR LOCATIONS WHERE EXPOSED. COLOR AS DIRECTED BY THE ARCHITECT IN PUBLIC SPACES, RED WHERE EXPOSED IN UNOCCUPIED SPACES SUCH AS EQUIPMENT ROOMS. PROVIDE HEAD GUARDS IN EQUIPMENT ROOMS AND SIMILAR LOCATIONS WHERE THE HEADS ARE SUBJECT TO DAMAGE. 8.TEST SYSTEMS AT 200 PSI FOR TWO HOURS IN ACCORDANCE WITH NFPA-13 AND 24 AND REQUIREMENTS OF AHJ AND PREPARE "CONTRACTORS MATERIAL AND TEST CERTIFICATE" AS PRESCRIBED BY NFPA STANDARDS. 9.PROVIDE A SPRINKLER HEAD CABINET AND PROVIDE SPARE SPRINKLER HEADS FOR EACH TYPE OF SPRINKLER HEADS IN ACCORDANCE WITH NFPA-13. 10.SIAMESE FIRE DEPARTMENT CONNECTION SHALL HAVE (2) - 2 1/2 INCH POLISHED BRASS INLET HOSE CONNECTIONS, 4" OUTLET PIPE, RED ENAMEL FINISH, CAST IRON EASE OFF CAPS, AUTOMATIC BRASS BALL DRIP CONNECTION, YARD MOUNT TYPE. 11.LABEL DRAIN PIPING, INSPECTOR'S TEST, MAIN DRAIN, SHUT-OFF VALVES, AND SIMILAR COMPONENTS. 12.SUBMIT FITTINGS PRODUCT DATA FOR ALL MATERIALS, INCLUDING PIPING FITTINGS, VALVES, HEADS, AND SIGNS. 13.SEE CIVIL DRAWINGS FOR UNDERGROUND PIPING MATERIALS. 14.PROVIDE AUXILIARY DRAINS FOR TRAPPED SECTIONS OF PIPING. 15.HAZARD CLASSIFICATION OF OCCUPANCIES, DENSITY AREA (GMP/SQ FT) AND HOSE DEMAND (GPM) DESIGN REQUIREMENTS ARE IN ACCORDANCE WITH NFPA-13. 16.THE FIRE PROTECTION CONTRACTOR SHALL LIMIT THE SPRINKLER PIPING MAINS SO AS TO BE LOCATED IN A 6" HORIZONTAL SPACE ABOVE THE CEILINGS, USING EITHER THE 6" OF SPACE DIRECTLY ABOVE THE CEILINGS, OR THE 6" OF SPACE DIRECTLY BELOW THE STRUCTURE. COORDINATION WITH MECHANICAL AND PLUMBING CONTRACTORS IS REQUIRED PRIOR TO SUBMISSION OF SPRINKLER SHOP DRAWINGS. 17.THE FIRE PROTECTION CONTRACTOR SHALL COORDINATE ALL MAIN PIPING RUNS THROUGH THE BUILDING WITH ALL TRADES. ANY EXPOSED PIPING ROUTING SHALL BE APPROVED BY ARCHITECT PRIOR TO FABRICATION AND INSTALLATION. 18.TO THE BEST OF THE ENGINEERS KNOWLEDGE, MICROBIAL INDUCED CORROSION (MIC) IS NOT OF CONCERN. SCHEDULE 40 BRANCH PIPING IS SPECIFIED, IN PART FOR CORROSION RESISTANCE. 19.THE WATER SUPPLY TO THE FIRE PROTECTION SYSTEM SHALL BE TESTED FOR CONTAMINANTS THAT MAY LEAD TO MICROBIAL CORROSION. IF POSSIBLE CONTAMINANTS ARE FOUND, PROTECTIVE MEASURES SHALL BE DESIGNED INTO THE SYSTEM. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROCUREMENT OF THE TEST, AND EVALUATION OF THE RESULTS. PROVIDE TEST RESULTS AND RECOMMENDATIONS TO THE DESIGN TEAM AND OWNER. 20.AT THE CONTRACTOR OPTION, FLEXIBLE HEADS MAY BE USED. HOWEVER, NO EXCESS FLEXIBLE PIPE MAY BE RESTING ON CEILING TILES. RESTRICT USE TO 3'-0" SECTIONS. 21.APPLICABLE CODES AND STANDARDS TO BE APPLIED: 21.1.2020 INTERNATIONAL BUILDING CODE AS ADOPTED BY NEW YORK STATE 21.2.2020 INTERNATIONAL FIRE PREVENTION CODE AS ADOPTED BY NEW YORK STATE 21.3.NFPA-13-2019 EDITION 21.4.CITY OF ITHACA MUNICIPAL CODE MECHANICAL ROOM ELEVATION SCALE: 1" = 1'-0"1 MECHANICAL ROOM PLAN & ELEVATIONP002 *BYPASS- CAN GO ABOVE OR BELOW WITHOUT INTERFERENCE WITH METER ℄ IN METER *BYPASS WILK INSZURNA CO M PA NY U350AOUT SPRINKLER RISER WATER METER, BACKFLOW PREVENTION ASSEMBLY 2'-8"PIPE TO OUTSIDE PIPE TAP BALL DRIP VALVE ELECTRICAL PANELS MOUNTED ON BACK WALL, SEE E-SERIES PLANS 6" X 2 12" X 2 12" WALL MOUNTED, SIAMESE F.D.C.2'-6"PAVER, SEE SITE PLAN CEILING 8'-3"2'-8" HOUSE PANEL MOUNTED ON SIDE WALL, SEE E-SERIES PLANS 2" DOMESTIC WATER SERVICE TO BLDG. UNITS 2" ZURN-WILKINS 2-350XL RPZ ASSEMBLY 4" MIN. AIR GAP; AIR GAP FITTINGS NOT PERMITTED 4 12" FUNNEL 3 12" PVC DRAIN SLOPED AT 14"/FT.1-HR. RATED WALL2'-6"PIPE SUPPORTS PER MANUF. REQ. COMBINED WATER FROM MAIN, 6" DIA., AWWA SPEC #C151 CLASS 350, CEMENT LINED DUCTILE IRON SEE P003/7 FOR THE THRU SLAB DETAIL 6" Ø ZURN-WILKINS, MODEL 350A DCVA W/BG VALVES, MOUNTED VERTICAL UP,℄ OF DEVICE 30" - 60" FROM F.F.E. 1'-1" (1'-0" MIN.) (2'-6" MIN.)(2'-6"MIN.)6" Ø RISER TO BLDG. SPRINKLERS 2" Ø BALL VALVE (TYP.) 2" X 1 12" REDUCER (TYP. OF 2) 1 12" WATER METER STRAINER ZURN FD2360 FLOOR DRAIN W/4" Ø SCH. 40 DWV DRAIN PIPE, SLOPE @ 14"/FT., CONNECT TO BLDG. WASTE SHUT 114" SQ. BODY 6" DIAMETER 518" 12" DIAMETER STANDPIPE (PAINTED BLACK) STANDPIPE (PAINTED RED) STANDPIPE GROUND LINE MARK FINISHED GRADE TAMPER SWITCH PADLOCK CONCRETE THRUST BLOCK; CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL FITTINGS. WEDGE ACTION RESTRAINTS, (TYP.) EXCESS PRESSURE RELIEF VALVE WATER FLOW SWITCH (MUST TIE INTO A CENTRAL STATION) FDC CHECK VALVE; UL/FM APPROVED WATER MOTOR ALARM ALARM VALVE W/GAUGES AND RETARD SEE P003/6 FOR THE THRU SLAB DETAIL 1-HR. RATED WALL12'-3" T.S. 396.62' 4'-0" T.F. 393.12' T.P. ~391.62'4'-8"1'-0"2'-6"POST INDICATOR VALVE (MIN. 32-FT. FROM BLDG.)1'-014"3'-41 4" 1'-0"12'-314"5'-63 4" 3 12" PVC DRAIN SLOPED AT 14"/FT. 6" X 2 12" X 2 12" WALL MOUNTED, SIAMESE F.D.C. MECHANICAL ROOM PLAN SCALE: 1" = 1'-0"2 TO BLDG. SPRINKLERS ZURN FD2360 FLOOR DRAIN & 4" Ø SDR35 PVC UNDER SLAB, CONNECT TO BLDG. 6" WASTE ON OPPOSITE SIDE COMBINED WATER FROM MAIN, 6" DIA., AWWA SPEC #C151 CLASS 350, CEMENT LINED DUCTILE IRON 2" DOMESTIC WATER SERVICE TO BLDG. UNITS OUTLET TO WALKWAY DOMESTIC WATER DISTRIBUTION MANIFOLD; (1) 2" Ø IN; MIN. (12) 34" Ø CW LINES OUT; ALSO UNIT MASTER VALVES & RADIO METERS EIGHT (8), 34" DIA. SERVICE LINES UP TO 2ND & 3RD FLOORS FOUR (4), 34" DIA. SERVICE LINES OUT TO 1ST FLOOR UNITS PROJECT NO.PROJECT:TITLE OF DRAWINGDRAWING NO. FIRST ISSUE DATE:0ISSUED/REVISIONS:DATE:123456ENGINEER:OWNER/DEVELOPER:112 N. MAIN ST.HORSEHEADS, NY 14845607-377-7990 | WWW.MASER-AE.COM119 S. CAYUGA STREETITHACA, NY 14850327 W. SENECA ST.ITHACA, NEW YORK 14850327 W. SENECA STREETA 5 4 3 2 16 B C D E A B C D E 78 5 4 3 2 1678 ISSUED FOR PERMIT08/19/2019REVISED FOR MECH. RM. EQUIP.06/04/20203-STORY, 12-UNIT APARTMENT BUILDINGREVISED FOR CONSTRUCTION06/17/2020DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT,ENGINEER, SURVEYOR OR LANDSCAPEARCHITECT TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THISDOCUMENT IS REQUIRED BY LAW TOAFFIX THEIR SEAL AND THE NOTATION,"ALTERED BY," FOLLOWED BY THEIRSIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.#VISUMDEVELOPMENT GROUPMAY 31, 2019 2019-008MIN. 1"MAX. 12"MIN. 1"MAX. 12"VARIESPIPE PROTECTION STEEL SADDLE (TOP & BOTTOM) STRAP HARD, NON-HEAT CONDUCTING MATERIAL PER NFPA 13 SPRINKLER PIPE INSULATION FIXING NUT STEEL ANGLE NUT W/PLATE WASHER NOTE: 1.ALL FABRICATED STEEL SHALL BE GALVANIZED OR PAINTED WITH TWO COATS OF ZINC CHROMATE WOOD JOIST MULTIPLE PIPE HANGER SCALE: N.T.S.5 CONTINUOUS WELD SEAL WATERTIGHT WITH MASTIC FACE OF WALL ESCUTCHEON PLATE COVER (ESCUTCHEON SHOULD BE ON BOTH SIDES) INSIDE FACE OF WALL 18" THICK CIRCULAR STEEL PLATE PIPE SLEEVE THROUGH WALL SCALE: N.T.S.6 CONTINUOUS WELD ESCUTCHEON PLATE COVER (ESCUTCHEON SHOULD BE ON BOTH SIDES) INSIDE FACE OF WALL 18" THICK CIRCULAR STEEL PLATE SEAL WATERTIGHT WITH MASTIC PIPE SLEEVE THROUGH SLAB SCALE: N.T.S.7 1 2" ANCHOR BOLT W/EXPANSION SHIELD RISER NIPPLE SPRINKLER MAIN WOOD JOIST WOOD JOIST SPRINKLER INSTALLED DIRECTLY TO TEE BRANCH PIPE SPRINKLER HEAD (UPRIGHT) SCALE: N.T.S.8 TEE 1" Ø GALV. PIPE CEILING SPRINKLER HEAD (PENDANT TYPE) SPRINKLER HEAD (UPRIGHT TYPE) LATERAL PIPE MAIN LINE REDUCER LATERAL PIPE 1" Ø GALV. PIPE CEILING SPRINKLER HEAD (PENDANT TYPE) SPRINKLER HEAD (UPRIGHT TYPE) LATERAL PIPE MAIN LINE REDUCER TEE ARRANGEMENT OF BRANCH LINES SUPPLYING SPRINKLER ABOVE & BELOW CEILING SCALE: N.T.S.3 PENDANT AND UPRIGHT SPRINKLER BRANCH SCALE: N.T.S.4 BEND 1" Ø GALV. PIPE CEILING SPRINKLER HEAD LATERAL PIPE REDUCER LATERAL PIPE 1" Ø GALV. PIPE CEILING SPRINKLER HEAD LATERAL PIPE REDUCER MAIN LINE DEFLECTOR PLATE 1" X 58" REDUCER LATERAL PIPE 1" Ø GALV. PIPE CEILING SPRINKLER HEAD LATERAL PIPE REDUCER TEE POST INDICATOR VALVE SCALE: N.T.S.2 SHUT 9" 1" SQUARE EXTENSION 114" SQ. BODY 6" DIAMETER 30" TO 42" 4'-0" MINIMUM 518" 12" DIAMETER STANDPIPE (PAINTED BLACK) STANDPIPE (PAINTED RED) TO RISER ROOM FIELD ADJUSTMENT NOTES: 1.REMOVE THE BODY FROM THE TOP OF THE INDICATOR POST ASSEMBLY. 2.CUT THE REQUIRED LENGTH OFF THE BOTTOM OF THE STANDPIPE FOR THE GROUND LINE TO MATCH UP WITH STANDPIPE GROUND LINE MARK. 3.CUT THE 1 INCH SQ. EXTENSION AT A DISTANCE OF 9 INCHES ABOVE THE TOP OF THE STANDPIPE. 4.SET THE "OPEN" AND "SHUT" TARGETS FOR THE APPROPRIATE VALVE SIZE. 5.RE-ATTACH THE BODY TO THE TOP OF THE INDICATOR POST ASSEMBLY. 6.ALL POST INDICATOR VALVES SHALL BE INSTALLED WITH AN ELECTRONIC UL LISTED TAMPER SWITCH. 7.THERE SHALL BE 36 INCHES OF UNOBSTRUCTED CLEARANCE AROUND THE PERIMETER OF ALL POST INDICATOR VALVES. 8.POST INDICATOR VALVE SHALL BE LOCATED AT A MINIMUM 32 FEET FROM BUILDING. STANDPIPE GROUND LINE MARK STANDPIPE POST INDICATOR ASSEMBLY WITH BODY REMOVED CL (7" MIN.) (10" MAX.) GROUND LINE OR FINISHED GRADE GROUND LINE OR FINISHED GRADE TAMPER SWITCH (SEE INSET) PADLOCK SHUT PADLOCK TAMPER SWITCH INSET ALL JOINTS TO THE MAIN SHALL BE RESTRAINED 12.375" 8.125" 1.82" 6.86" SCH. 40 DWV PIPE 4" ZURN FD2360 FLOOR DRAIN SCALE: N.T.S.1 FIRE PROTECTION DETAILSP003 DW DW DW DW REF.REF. REF.REF. W/DW/D W/D W/D WH WH RANGE RANGERANGE RANGE WH WH 6-IN. WASTE LINE TO STREET, SEE CIVIL PLANS 6" X 3" X 3" TEE6" X 6" X 3" TEE 6" X 6" X 6" TEE; CONNECT MECH. RM. DRAIN UNDER SLAB 6" X 6" X 3" TEE 6-IN. COMBINED DOMESTIC/FIRE SERVICE FROM MAIN, SEE CIVIL PLANS FROM 2ND FL. FROM 3RD FL. FROM 2ND FL. FROM 3RD FL. FROM 2ND FL. FROM 3RD FL. FROM 2ND FL. FROM 3RD FL. PROJECT NO.PROJECT:TITLE OF DRAWINGDRAWING NO. FIRST ISSUE DATE:0ISSUED/REVISIONS:DATE:123456ENGINEER:OWNER/DEVELOPER:112 N. MAIN ST.HORSEHEADS, NY 14845607-377-7990 | WWW.MASER-AE.COM119 S. CAYUGA STREETITHACA, NY 14850327 W. SENECA ST.ITHACA, NEW YORK 14850327 W. SENECA STREETA 5 4 3 2 16 B C D E A B C D E 78 5 4 3 2 1678 ISSUED FOR PERMIT08/19/2019REVISED FOR MECH. RM. EQUIP.06/04/20203-STORY, 12-UNIT APARTMENT BUILDINGREVISED FOR CONSTRUCTION06/17/2020DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT,ENGINEER, SURVEYOR OR LANDSCAPEARCHITECT TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THISDOCUMENT IS REQUIRED BY LAW TOAFFIX THEIR SEAL AND THE NOTATION,"ALTERED BY," FOLLOWED BY THEIRSIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.#VISUMDEVELOPMENT GROUPMAY 31, 2019 2019-008 FIRST FLOOR UNITS 101 - 104 SCALE: 3/8" = 1'-0"1 FIRST FLOOR PLUMBING PLANP101 UNIT 101 UNIT 102 UNIT 103 UNIT 104 DOMESTIC WATER DISTRIBUTION MANIFOLD; 2" Ø SERVICE IN; MIN. 12 CW OUTLETS @ 34" Ø OUT MECH. EIGHT (8), 34" DIA. SERVICE LINES UP TO 2ND & 3RD FLOORS FOUR (4), 3 4" DIA. SERVICE LINES OUT TO 1ST FLOOR UNITS TYP. UNIT PLUMBING FIXTURE SCHEDULE: 1.DISHWASHER 1.1.1/2" Ø HW 1.2.1-1/2" Ø WASTE 2.SINK 2.1.3/8" Ø CW 2.2.3/8" Ø HW 2.3.1-1/2" Ø WASTE 3.WATER HEATER 3.1.3/4" Ø CW 3.2.3/4" Ø HW 4.TOILET 4.1.3/8" Ø CW 4.2.3" Ø WASTE 5.BATH TUB 5.1.3/8" Ø CW 5.2.3/8" Ø HW 5.3.1-1/2" Ø WASTE 6.WASHER/DRYER 6.1.1/2" Ø CW 6.2.1/2" Ø HW 6.3.2" WASTE NOTE: 1.ALL WASTE CONNECTIONS FROM UNIT TO MAIN SHALL BE UNDER THE SLAB AND CLEANOUTS TO TOP OF SLAB. SEE P002 FOR ELEVATION AND LARGE SCALE PLAN DW DW DW DW UP REF. REF.REF. REF. W/DW/D W/D W/D WH WHWH WH RANGE RANGERANGE RANGE 3" Ø WASTE TO 1ST FLOOR AND TEE INTO BLDG. MAIN; VENT UP TO ROOF 3" Ø WASTE TO 1ST FLOOR AND TEE INTO BLDG. MAIN; VENT UP TO ROOF 3" Ø WASTE TO 1ST FLOOR AND TEE INTO BLDG. MAIN; VENT UP TO ROOF PROJECT NO.PROJECT:TITLE OF DRAWINGDRAWING NO. FIRST ISSUE DATE:0ISSUED/REVISIONS:DATE:123456ENGINEER:OWNER/DEVELOPER:112 N. MAIN ST.HORSEHEADS, NY 14845607-377-7990 | WWW.MASER-AE.COM119 S. CAYUGA STREETITHACA, NY 14850327 W. SENECA ST.ITHACA, NEW YORK 14850327 W. SENECA STREETA 5 4 3 2 16 B C D E A B C D E 78 5 4 3 2 1678 ISSUED FOR PERMIT08/19/2019REVISED FOR MECH. RM. EQUIP.06/04/20203-STORY, 12-UNIT APARTMENT BUILDINGREVISED FOR CONSTRUCTION06/17/2020DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT,ENGINEER, SURVEYOR OR LANDSCAPEARCHITECT TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THISDOCUMENT IS REQUIRED BY LAW TOAFFIX THEIR SEAL AND THE NOTATION,"ALTERED BY," FOLLOWED BY THEIRSIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.#VISUMDEVELOPMENT GROUPMAY 31, 2019 2019-008 SECOND FLOOR UNITS 201 - 204 SCALE: 3/8" = 1'-0"1 SECOND FLOOR PLUMBING PLANP102 TYP. UNIT PLUMBING FIXTURE SCHEDULE: 1.DISHWASHER 1.1.1/2" Ø HW 1.2.1-1/2" Ø WASTE 2.SINK 2.1.3/8" Ø CW 2.2.3/8" Ø HW 2.3.1-1/2" Ø WASTE 3.WATER HEATER 3.1.3/4" Ø CW 3.2.3/4" Ø HW 4.TOILET 4.1.3/8" Ø CW 4.2.3" Ø WASTE 5.BATH TUB 5.1.3/8" Ø CW 5.2.3/8" Ø HW 5.3.1-1/2" Ø WASTE 6.WASHER/DRYER 6.1.1/2" Ø CW 6.2.1/2" Ø HW 6.3.2" WASTE UNIT 201 UNIT 202 UNIT 203 UNIT 204 FOUR (4), 3 4" DIA. SERVICE LINES UP TO THE 3RD FLOOR FOUR (4), 34" DIA. SERVICE LINES OUT TO 2ND FLOOR UNITS FROM 3RD FLOOR FROM 3RD FLOOR FROM 3RD FLOOR DW DW DW DW UP REF. REF. REF. REF. W/DW/D W/D W/D WH WHWH WH RANGE RANGERANGE RANGE 3" Ø WASTE TO 1ST FLOOR AND TEE INTO BLDG. MAIN; VENT UP TO ROOF 3" Ø WASTE TO 1ST FLOOR AND TEE INTO BLDG. MAIN; VENT UP TO ROOF 3" Ø WASTE TO 1ST FLOOR AND TEE INTO BLDG. MAIN; VENT UP TO ROOF PROJECT NO.PROJECT:TITLE OF DRAWINGDRAWING NO. FIRST ISSUE DATE:0ISSUED/REVISIONS:DATE:123456ENGINEER:OWNER/DEVELOPER:112 N. MAIN ST.HORSEHEADS, NY 14845607-377-7990 | WWW.MASER-AE.COM119 S. CAYUGA STREETITHACA, NY 14850327 W. SENECA ST.ITHACA, NEW YORK 14850327 W. SENECA STREETA 5 4 3 2 16 B C D E A B C D E 78 5 4 3 2 1678 ISSUED FOR PERMIT08/19/2019REVISED FOR MECH. RM. EQUIP.06/04/20203-STORY, 12-UNIT APARTMENT BUILDINGREVISED FOR CONSTRUCTION06/17/2020DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT,ENGINEER, SURVEYOR OR LANDSCAPEARCHITECT TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THISDOCUMENT IS REQUIRED BY LAW TOAFFIX THEIR SEAL AND THE NOTATION,"ALTERED BY," FOLLOWED BY THEIRSIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.#VISUMDEVELOPMENT GROUPMAY 31, 2019 2019-008 THIRD FLOOR UNITS 301 - 304 SCALE: 3/8" = 1'-0"1 THIRD FLOOR PLUMBING PLANP103 TYP. UNIT PLUMBING FIXTURE SCHEDULE: 1.DISHWASHER 1.1.1/2" Ø HW 1.2.1-1/2" Ø WASTE 2.SINK 2.1.3/8" Ø CW 2.2.3/8" Ø HW 2.3.1-1/2" Ø WASTE 3.WATER HEATER 3.1.3/4" Ø CW 3.2.3/4" Ø HW 4.TOILET 4.1.3/8" Ø CW 4.2.3" Ø WASTE 5.BATH TUB 5.1.3/8" Ø CW 5.2.3/8" Ø HW 5.3.1-1/2" Ø WASTE 6.WASHER/DRYER 6.1.1/2" Ø CW 6.2.1/2" Ø HW 6.3.2" WASTE UNIT 301 UNIT 302 UNIT 303 UNIT 304 FOUR (4), 34" DIA. SERVICE LINES OUT TO 3RD FLOOR UNITS