HomeMy WebLinkAbout327 W. Seneca Elec. Plans_Rev. No. 1_2020.08.03D/B ELECTRICAL LEGEND (ALL 125 SINGLE PHASE 15 & 20-AMP BRANCH CIRCUITS TO BE TAMPER-RESISTANT RECEPTACLES.) BRANCH CIRCUITS TO BE TAMPER-RESISTANT RECEPTACLES.)2SSCHOSEN BY OWNER WALL MOUNTED LIGHT FIXTURE 2-WAY SWITCH, +44" TYP. U.N.O. SINGLE POLE WALL SWITCH, +44" TYP. U.N.O. 110 VOLT DUPLEX WALL OUTLET, 12" A.F.F. TYP., U.N.O. COUNTER, +45" A.F.F. TYP., U.N.O. (ALL 125 SINGLE PHASE 15 & 20-AMP CONDUIT CONCEALED IN CEILING 110 VOLT DUPLEX WALL OUTLET INSTALLED ABOVE GROUND FAULT INTERRUPT CIRCUIT CEILING FAN w/ LIGHT FIXTURE GFI CEILING MOUNTED EXHAUST FAN RECESSED LED LIGHTS CEILING MOUNTED PENDANT LIGHT FIXTURE WITH MOTION SENSORS DUCT LINE CHOSEN BY OWNER CEILING MOUNTED PENDANT LIGHT FIXTURE FIXTURE; CHOSEN BY OWNER CHOSEN BY OWNER VANITY LIGHT CHOSEN BY OWNER DOORBELL SMOKE DETECTOR, HARD WIREDS PROJECT NO.PROJECT:TITLE OF DRAWINGDRAWING NO. FIRST ISSUE DATE:0ISSUED/REVISIONS:DATE:123456ENGINEER:OWNER/DEVELOPER:112 N. MAIN ST.HORSEHEADS, NY 14845607-377-7990 | WWW.MASER-AE.COM119 S. CAYUGA STREETITHACA, NY 14850327 W. SENECA ST.ITHACA, NEW YORK 14850327 W. SENECA STREETA 5 4 3 2 16 B C D E A B C D E 78 5 4 3 2 1678 ISSUED FOR PERMIT08/19/2019REVISED FOR MECH. RM. EQUIP.06/04/20203-STORY, 12-UNIT APARTMENT BUILDINGREVISED FOR CONSTRUCTION06/17/2020DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT,ENGINEER, SURVEYOR OR LANDSCAPEARCHITECT TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THISDOCUMENT IS REQUIRED BY LAW TOAFFIX THEIR SEAL AND THE NOTATION,"ALTERED BY," FOLLOWED BY THEIRSIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.#VISUMDEVELOPMENT GROUPMAY 31, 2019 2019-008 REVISED TO ADD ADDT'L ELEC. INFO.08/03/2020ELECTRICAL GENERAL NOTESE001 I GENERAL NOTES: 1.INSTALLATION OF ALL WORK SHALL BE IN ACCORDANCE WITH THE FOLLOWING REGULATIONS, CODES, ETC. 1.1.LOCAL CODES AND ORDINANCES 1.2.THE EDITION OF THE NATIONAL ELECTRICAL CODE NFPA 70 (NEC) IN EFFECT. 2.PRIOR TO BEGINNING ANY WORK, SECURE NECESSARY PERMITS OR CLEARANCES FROM THE AUTHORITIES HAVING JURISDICTION. PROVIDE ALL LABOR AND MATERIALS FOR A COMPLETE INSTALLATION. WORK SHALL BE EXECUTED BY EXPERIENCED ELECTRICIANS WHO ARE LICENSED IN THE JURISDICTION WHERE THE PROJECT IS LOCATED. 3.THE CONTINUITY OF ALL EXISTING CIRCUITS TO REMAIN SHALL BE MAINTAINED 4.ALL DEVICES SHALL BE WHITE WITH COMPATIBLE PLASTIC PLATES, INSTALLED FOR ADA COMPLIANCE U.N.O. 5.LOW VOLTAGE CONTRACTORS ARE REQUIRED TO OBTAIN INDEPENDENT PERMITS FROM THE AHJ PRIOR TO STARTING THEIR WORK. 6.UTILIZE "DEEP" 4-SQUARES WHERE REQUIRED TO COMPLY WITH NEC 314.6. EXTRA CONSIDERATION SHALL BE GIVEN TO BOXES SUPPLYING HOME-RUNS. 7.CONFIRM EXACT ROUGH-IN DIMENSIONS WITH ARCHITECTURAL DRAWINGS, KITCHEN EQUIPMENT, FURNITURE PLAN (IF AVAILABLE) AND SPECIALTY EQUIPMENT. 8.GENERAL CONTRACTOR TO SAW-CUT/REMOVE/PATCH EXISTING ARCHITECTURAL SURFACES INCLUDING BUT NOT LIMITED TO SLABS, WALLS AND ROOFS. 9.SHARED NEUTRALS ARE NOT PERMISSIBLE U.N.O. 10.CONDUCTOR TICK MARKS ARE SHOWN FOR CONVENIENCE ONLY, THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL CONDUCTORS WHETHER SHOWN OR NOT INCLUDING "TRAVELERS" AS NECESSARY FOR COMPLETELY OPERATIONAL SYSTEMS. 11.PROVIDE GFCI-TYPE RECEPTACLES WITHIN 6' OF ANY SINK, IN KITCHENS, BATHROOMS, LAUNDRY AREAS AND OUTDOORS PER NEC 210.8. 12.PROVIDE AFCI PROTECTION IN DWELLING UNITS PER NEC 210.12. 13.ELECTRICAL DEVICE INSTALLATION SHALL COMPLY WITH ACCESSIBILITY CODES ADOPTED FOR NEW MEXICO. SPECIFICALLY; MOUNT APPLICABLE SWITCHES, RECEPTACLES, AND ENVIRONMENTAL CONTROLS SO THAT THEY ARE MOUNTED WITH THE TOP OF THE DEVICE NO HIGHER THAN 48 INCHES ABOVE FINISHED FLOOR (AFF) AND THE BOTTOM OF THE DEVICE NO LOWER THAN 15 INCHES AFF. ELECTRICAL DEVICES ABOVE COUNTERTOP (AC) OR OTHER OBSTRUCTION SHOULD COMPLY WITH ICC/ANSI 117.1-2003 SECTION 308. 14.EXTERIOR LIGHTING SHALL COMPLY WITH THE LAS CRUCES OUTDOOR LIGHTING ORDINANCE AND THE NEW MEXICO NIGHT SKY PROTECTION ACT. 15.THE ELECTRICAL PLANS ARE DIAGRAMMATIC ONLY. COORDINATE ELECTRICAL EQUIPMENT LOCATION AND INSTALLATION WITH EQUIPMENT BEING SERVED. PROVIDE ALL POWER AND TELECOMMUNICATION FINAL CONNECTIONS TO THE SYSTEM FURNITURE AS REQUIRED. 16.ALL EQUIPMENT SUCH AS RELAYS, SWITCHES, PANELS, AND OTHER APPURTENANCES SHALL HAVE IDENTIFICATION PLATES OF BLACK LAMINATED PLASTIC WITH 1/2" WHITE LETTERS. ALL JUNCTION BOXES IN CEILING CAN BE MARKED WITH BLACK PERMANENT MARKER ON COVER PLATES AS PANEL DESIGNATION AND CIRCUIT NUMBER FROM WHICH THEY ARE FED. 17.ALL CONDUCTORS SHALL BE IDENTIFIED. ALL WIRING DEVICES SHALL BE USED WITH TYPED LABEL ON THE COVER PLATE IDENTIFYING THE PANEL DESIGNATION AND CIRCUIT NUMBER FROM WHICH THEY ARE FED. 18.ALL EQUIPMENT SHALL BE "UL" LISTED. 19.ELECTRICAL SYSTEMS SHALL BE GROUNDED PER ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. 20.ALL CONNECTIONS TO DEVICES SHALL BE TAPED WITH SCOTCH 33 ELECTRICAL TAPE. 21.ALL CONDUITS AND JUNCTION BOXES SHALL BE CONCEALED IN FINISHED AREAS. PRIOR TO CONCEALMENT OF NEW CONSTRUCTION, ALL WORK BEHIND FINISHED SURFACES SHALL BE INSPECTED BY THE OWNER'S REPRESENTATIVE. 22.CONTRACTOR SHALL INFORM THE OWNER'S REPRESENTATIVE PRIOR TO BEGINNING CONSTRUCTION AND PRIOR TO COMPLETION OF CONSTRUCTION TO ALLOW SUFFICIENT TIME FOR COORDINATION OF EXISTING BUILDING ACTIVITIES WITH THE CONSTRUCTION WORK. 23.CONTROL WIRING SHALL BE TAGGED AT EACH END AND TERMINATED WHERE WORK HAS BEEN PERFORMED IN ACCORDANCE WITH EQUIPMENT MANUFACTURES SPECIFICATIONS. 24.IF MATERIAL OR EQUIPMENT IS INSTALLED BEFORE IT IS APPROVED, THE CONTRACTOR SHALL BE LIABLE FOR ITS REMOVAL AND REPLACEMENT AT NO ADDITIONAL CHARGE OR IF IN THE OPINION OF THE ARCHITECT OR ENGINEER, THE MATERIAL OR EQUIPMENT DOES NOT MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. 25.THE CONTRACTOR SHALL INCLUDE IN THE WORK, WITHOUT EXTRA COST, ANY LABOR, MATERIALS, SERVICES, APPARATUS, AND DRAWINGS IN ADDITION TO CONTRACT DOCUMENTS, IN ORDER TO COMPLY WITH ALL APPLICABLE LAWS, INDICATED AND/OR SPECIFIED. PROVIDE ALL ELECTRICAL EQUIPMENT WITH ALL NECESSARY ASSOCIATED ACCESSORIES AND CONDUIT INFRASTRUCTURE AS REQUIRED TO ENSURE A COMPLETE AND OPERATIONAL SYSTEM AT NO ADDITIONAL COST TO OWNER. 26.BEFORE SUBMITTING BIDS, THE CONTRACTOR SHALL VISIT THE SITE AND EXAMINE ALL ADJOINING EXISTING BUILDINGS, EQUIPMENT, AND SPACE CONDITIONS ON WHICH HIS WORK IS IN ANY WAY DEPENDANT FOR THE BEST WORKMANSHIP AND OPERATION ACCORDING TO THE INTENT OF THE SPECIFICATIONS AND DRAWINGS. HE SHALL REPORT TO THE ARCHITECT/ENGINEER ANY CONDITION WHICH MIGHT PREVENT HIM FROM INSTALLING HIS EQUIPMENT IN THE MANNER SPECIFIED OR AS SHOWN IN CONTRACT DOCUMENTS TEN BUSINESS DAYS PRIOR TO SUBMISSION OF BIDS. NO CONSIDERATION OR ALLOWANCE WILL BE GRANTED FOR FAILURE TO VISIT THE SITE, NOR FOR ANY ALLEGED MISUNDERSTANDING OF MATERIALS TO BE FURNISHED OR WORK TO BE PERFORMED. THE CONTRACTOR SHALL INCLUDE IN HIS BID PRICE ALL LABOR AND MATERIAL THAT MAY EFFECT HIS WORK. 27.THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER IN WRITING OF ANY DISCOVERED CONFLICTS BETWEEN EXISTING INSTALLATIONS WHICH ARE NOT SCHEDULED FOR DEMOLITION AND THE NEW WORK INDICATED WITHIN THE CONTRACT DOCUMENTS. SUCH NOTIFICATION SHALL BE ACCOMPANIED BY A DRAWING DELINEATING THE PROPOSED SOLUTION PRIOR TO STARTING ANY WORK IN THE AFFECTED AREA. 28.ALL NEW SLAB PENETRATIONS MUST BE X-RAYED OR RADAR PRIOR TO CORE DRILLING. OBTAIN APPROVAL FROM OWNER'S REPRESENTATIVE PRIOR TO ANY CORE DRILLING. 29.ALL MATERIALS AND WORK SHALL BE ACCORDING TO BASE BUILDING SPECIFICATIONS UNLESS OTHERWISE NOTED. 30.ALL CONDUCTORS SHALL BE COPPER. MINIMUM SIZE SHALL BE #12 AWG. CONDUCTOR #10 AWG AND SMALLER SHALL BE SOLID. CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED. CONDUCTOR SHALL HAVE THHN/THWN INSULATION OR AS NOTED. 31.NUMBER OF WIRES MAY NOT BE INDICATED FOR ALL CIRCUITS, ONLY THOSE WHERE CLARIFICATION IS NECESSARY. PROVIDE ALL WIRE NECESSARY FOR THE PROPER FUNCTION OF THE SYSTEM WHETHER INDICATED ON PLAN OR NOT. 32.REFER TO ARCHITECTURAL DRAWINGS FOR THE EXACT LOCATION, ELEVATION, MOUNTING HEIGHTS AND DETAILS OF ALL LIGHT FIXTURES AND DEVICES. REPORT ANY DISCREPANCIES TO THE ARCHITECT IMMEDIATELY. 33.VERIFY DOOR SWINGS BEFORE INSTALLING LIGHT SWITCHES. 34.GANG ALL SWITCHES SHOWN TO BE INSTALLED AT SAME LOCATION UNDER A SINGLE COVER PLATE. PROVIDE BARRIERS SWITCH BOX AS REQUIRED TO SEPARATE 120V CIRCUITS FROM 277V CIRCUITS AND 277V CIRCUITS OF DIFFERENT PHASE. 35.PROVIDE PLASTER RING WITH PULL STRING TO SPACE ABOVE SUSPENDED CEILING FOR ALL TELEPHONE, DATA, FAX, MODEM, CATV, CARD READER, ETC. OUTLETS INSTALLED IN HOLLOW PARTITIONS. PROVIDE 3/4" EMPTY CONDUIT AND PULL STRING TO SPACE ABOVE SUSPENDED CEILING FOR THESE OUTLETS INSTALLED IN AN INSULATED PARTITION. PROVIDE 1" E.C. WITH 2 STRINGS FOR COMBINATION DATA/TEL OUTLET. 36.MAINTAIN INTEGRITY OF THE FIRE RATED CONSTRUCTION WHERE CONDUITS PASS THROUGH WALLS AND FLOORS. 37.ALL BACK BOXES INSTALLED ON OPPOSITE SIDES OF THE SAME PARTITION SHALL BE STAGGERED. DO NOT MOUNT THE BACK BOXES BACK TO BACK. 38.TYPE MC CABLE MAY BE USED IN LIEU OF EMT FOR BRANCH CIRCUITS, IN DRYWALL PARTITION AND IN CEILING PLENUM WHERE IS ALLOWED BY NEC AND THE BUILDING OWNER. (MC CABLE FOR ISOLATED CIRCUIT SHALL HAVE TWO (2) SEPARATE GROUNDING CONDUCTORS). 39.CONTRACTOR'S SCOPE OF WORK INCLUDES TRACING ALL EXISTING CIRCUITS IN THE CONSTRUCTION AREA BACK TO SOURCE. IF REMOVAL OF EXISTING ELECTRICAL EQUIPMENT AFFECTS ANY EXISTING CIRCUITS, CONTRACTOR SHALL PROVIDE CIRCUIT BREAKERS, WIRING, CONDUIT, ETC. REQUIRED TO RECONNECT EXISTING-TO-REMAIN ELECTRICAL EQUIPMENT BACK TO SOURCE. 40.PROVIDE ACCESS PANELS IN ALL INACCESSIBLE JUNCTION BOXES AS REQUIRED BY THE N.E.C. 41.CONTRACTOR SHALL PROVIDE 50% STEP-DIM BALLASTS IN ALL LIGHTING FIXTURES WHERE TWO LEVELS OF SWITCHING ARE INDICATED. 42.ALL EXISTING AND NEW PANELS IMPACTED BY THIS PROJECT SHALL BE PROVIDED WITH NEW UPDATED TYPEWRITTEN PANEL SCHEDULES INDICATING THE FINAL ROOM NUMBER AND THE EQUIPMENT OR DEVICES SERVED BY THE CIRCUIT. CONTRACTOR TO BE BALANCE THE NEW LOADS ON ALL THREE PHASES FOR EACH PANELBOARD WHERE WORK HAS BEEN PERFORMED IN ACCORDANCE WITH EQUIPMENT MANUFACTURER'S SPECIFICATIONS 43.INSTALLATION OF EQUIPMENT, COMPONENTS AND WIRING FOR ELECTRICAL SYSTEMS SHALL BE IN ACCORDANCE WITH REQUIREMENTS OF EQUIPMENT MANUFACTURER. 44.DELIVER PRODUCTS TO PROJECT SITE IDENTIFIED WITH NAMES, MODEL NUMBERS, TYPES, GRADES, COMPLIANCE LABELS, AND OTHER INFORMATION NEEDED FOR DISTINCT IDENTIFICATION; ADEQUATELY PACKAGED AND PROTECTED TO PREVENT DAMAGE DURING SHIPMENT, STORAGE, AND HANDLING. PROTECT STORED EQUIPMENT AND MATERIALS FROM DAMAGE. COMPLY WITH MANUFACTURER'S RIGGING AND MOVING INSTRUCTIONS FOR UNLOADING EQUIPMENT AND MOVING INTO FINAL LOCATION. 45.CONTRACTOR TO COORDINATE ELECTRICAL WORK TO AVOID INTERFERENCE BETWEEN ALL OTHER TRADES. 45.1.DETERMINE INTERFERENCE BEFORE WORK IS FABRICATED OR INSTALLED. THE CONTRACTOR SHALL BE THOROUGHLY FAMILIAR WITH ALL DETAILS OF WORK AND WORKING CONDITIONS AND COORDINATE WORK DURING PRELIMINARY STAGES TO ENSURE ACTUAL ERECTION WILL PROCEED WITHOUT INTERFERENCE. COORDINATION IS OF PARAMOUNT IMPORTANCE AND NO REQUESTS FOR ADDITIONAL PAYMENT WILL BE CONSIDERED WHERE REQUEST IS BASED ON INTERFERENCE. 45.2.WHERE JOB CONDITIONS REQUIRE REASONABLE DEVIATIONS FROM CONTRACT DOCUMENTS, MAKE DEVIATIONS WITHOUT ADDITIONAL COST TO OWNER, AFTER OBTAINING APPROVAL OF ARCHITECT. 45.3.PROVIDE MAXIMUM PRACTICAL SPACE FOR OPERATION, REPAIR, REMOVAL, AND TESTING OF ELECTRICAL EQUIPMENT. APPROVED DEVIATIONS MAY BE MADE TO PROVIDE REQUIRED ACCESSIBILITY. 45.4.KEEP CONDUITS, WIREWAYS AND SIMILAR ITEMS AS CLOSE AS POSSIBLE TO CEILING, WALLS AND COLUMNS IN ORDER TO TAKE UP MINIMUM AMOUNT OF SPACE. 45.5.PROVIDE OFFSETS, FITTINGS AND SIMILAR ITEMS NECESSARY TO ACCOMPLISH REQUIREMENTS OF COORDINATION WITHOUT ADDITIONAL EXPENSE TO OWNER. 45.6.PROVIDE ACCESS TO AND CLEARANCES AROUND EQUIPMENT AS REQUIRED BY THE N.E.C. 46.LIGHTING FIXTURES SHALL BE INDIVIDUALLY SUPPORTED FROM THE STRUCTURAL FRAMING MEMBERS ABOVE. 47.CONTRACTOR SHALL PROVIDE WRITTEN CERTIFICATION THAT ALL PRODUCTS, MATERIALS AND PROCESSES INSTALLED IN THE SPACE CONTAINS NO ASBESTOS OR PCB. 48.TESTING: 48.1.TEST AND ADJUST EQUIPMENT AND SYSTEMS INSTALLED AND DEMONSTRATE PROPER OPERATION TO OWNER'S REPRESENTATIVE. NO EQUIPMENT SHALL BE TESTED OR OPERATED FOR ANY PURPOSE UNTIL IT HAS BEEN FULLY PREPARED FOR OPERATION IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 48.2.SHOW, BY DEMONSTRATION IN SERVICE, THAT ALL CIRCUITS AND DEVICES ARE IN GOOD OPERATING CONDITION. EACH PIECE OF EQUIPMENT AND COMPONENT OF THE ELECTRICAL SYSTEM SHALL FUNCTION NOT LESS THAN FIVE TIMES IN COURSE OF THE ACCEPTANCE TESTS. 49.ELECTRICAL CONTRACTOR TO COORDINATE WITH MECHANICAL, PLUMBING AND OTHER TRADES TO PROVIDE ALL EQUIPMENT ASSOCIATED WITH THEIR RESPECTIVE TRADES WITH NECESSARY WIRING AND CONDUIT INFRASTRUCTURE FOR ALL SENSORS, AND CONTROL SYSTEMS AS REQUIRED. SERVICE SIZING CALCULATIONS - LOAD RECAP: 1.STANDARD METHOD: SEE THE LOAD SHEETS, THIS PAGE, TO THE RIGHT, FOR EACH UNIT TYPE. ARTICLE 220, PART III. 2.TOTAL CONNECTED LOADS: 2.1.UNITS 101/104, 201/204, 301/304 = 19.5 KVA / UNIT (117.0 KVA) 2.2.UNITS 102/103, 202/203, 302/303 = 18.1 KVA / UNIT (108.6 KVA) 2.3.HOUSE PANEL = 6 KVA 2.4.TOTAL = 231.6 KVA 3.DEMAND FACTOR PER NEC TBL. 220.84: 12-13 UNITS: 3.1.231.6 KVA X 0.41 DEMAND FACTOR = 95.0 KVA (396A) 4.SERVICE CONFIGURATION: 4.1.400A, 1-PHASE/3-WIRE, 120/240V. 5.SERVICE CONDUCTOR SIZE: 5.1.PARALLELED IN TWO RACEWAYS (NEC 240.4(B)). 5.2.396A / 2 RACEWAYS = 198A / CONDUCTOR 5.3.PER TABLE 310.15(B)(16): 5.3.1.SIZE: TWO (2) SETS OF FOUR (4) 300 MCM XHHW-AL IN 3" RMC 6.GROUNDING ELECTRODE CONDUCTOR: 6.1.300kcmil X 2 = 600kcmil 6.2.THROUGH 600kcmil = 1/0 AWG (TABLE 250.66) 7.FEEDER INSTALLATION: 7.1.INCLUDE EQUIPMENT GROUNDING CONDUCTOR IN EACH RACEWAY. 7.2.PER SECTION 250.118 AND TABLE 250.122, SIZE FOR 600kcmil IS 1 AWG TO EACH RACEWAY. MAINS S N N #1 15A #23 BATH LIGHTS 14/2 AWG 14/2 AWG 14/2 AWG 14/2 AWG 14/2 AWG #3 15A #5 15A #7 15A #9 15A BATH VENT FAN LIVING, DINING, KITCHEN LIGHTS BEDROOM #1 FAN/LIGHTS BEDROOM #1 OUTLETS LIVING/DINING OUTLETS KITCHEN OUTLETS 14/2 AWG 14/2 AWG 12/2 AWG #2 15A #4 15A #6 20A BATH OUTLETS 14/2 AWG #8 15A WASHER & DRYER HOT WATER TANK STOVE BATH WALL HEAT DISHWASHER PANEL GFCI STOVE WASHER & DRYER BASEBOARD HEAT BASEBOARD HEAT REFRIGERATOR 8/2 AWG #12 #14 40A 12/2 AWG #10 20A #16 #18 30A #22 15A #24 #11 15A #13 #15 30A #21 10/2 AWG 10/2 AWG 14/2 AWG 14/2 AWG 14/2 AWG #20 15A OPEN OPEN OPEN OPEN OPEN #19 #17 MAINS S N N #1 15A #23 BATH LIGHTS 14/2 AWG 14/2 AWG 14/2 AWG 14/2 AWG 14/2 AWG #3 15A #5 15A #7 15A #9 15A BATH VENT FAN LIVING, DINING, KITCHEN LIGHTS BEDROOM #1 FAN/LIGHTS BEDROOM #1 OUTLETS LIVING/DINING OUTLETS KITCHEN OUTLETS 14/2 AWG 14/2 AWG 12/2 AWG #2 15A #4 15A #6 20A BATH OUTLETS 14/2 AWG #8 15A WASHER & DRYER HOT WATER TANK STOVE BATH WALL HEAT DISHWASHER PANEL GFCI STOVE WASHER & DRYER BASEBOARD HEAT BASEBOARD HEAT REFRIGERATOR 8/2 AWG #12 #14 40A 12/2 AWG #10 20A #16 #18 30A #22 15A #24 #11 15A 14/2 AWG #15 15A 10/2 AWG #17 #19 30A #21 10/2 AWG BEDROOM #2 OUTLETS BEDROOM #2 FAN/LIGHTS 14/2 AWG 14/2 AWG 14/2 AWG 14/2 AWG #20 15A #13 15A OPEN OPEN OPEN MAINS S N N #1 15A #23 BATH LIGHTS 14/2 AWG 14/2 AWG 14/2 AWG 14/2 AWG 14/2 AWG #3 15A #5 15A #7 15A #9 15A BATH VENT FAN LIVING, DINING, KITCHEN LIGHTS BEDROOM #1 FAN/LIGHTS BEDROOM #1 OUTLETS LIVING/DINING OUTLETS KITCHEN OUTLETS 14/2 AWG 14/2 AWG 12/2 AWG #2 15A #4 15A #6 20A BATH OUTLETS 14/2 AWG #8 15A WASHER & DRYER HOT WATER TANK STOVE BATH WALL HEAT DISHWASHER PANEL GFCI STOVE WASHER & DRYER BASEBOARD HEAT BASEBOARD HEAT REFRIGERATOR 8/2 AWG #12 #14 40A 12/2 AWG #10 20A #16 #18 30A #22 15A #24 #11 15A #13 #15 30A #21 10/2 AWG 10/2 AWG 14/2 AWG 14/2 AWG 14/2 AWG #20 15A OPEN OPEN OPEN OPEN OPEN #19 #17 PROJECT NO.PROJECT:TITLE OF DRAWINGDRAWING NO. FIRST ISSUE DATE:0ISSUED/REVISIONS:DATE:123456ENGINEER:OWNER/DEVELOPER:112 N. MAIN ST.HORSEHEADS, NY 14845607-377-7990 | WWW.MASER-AE.COM119 S. CAYUGA STREETITHACA, NY 14850327 W. SENECA ST.ITHACA, NEW YORK 14850327 W. SENECA STREETA 5 4 3 2 16 B C D E A B C D E 78 5 4 3 2 1678 ISSUED FOR PERMIT08/19/2019REVISED FOR MECH. RM. EQUIP.06/04/20203-STORY, 12-UNIT APARTMENT BUILDINGREVISED FOR CONSTRUCTION06/17/2020DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT,ENGINEER, SURVEYOR OR LANDSCAPEARCHITECT TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THISDOCUMENT IS REQUIRED BY LAW TOAFFIX THEIR SEAL AND THE NOTATION,"ALTERED BY," FOLLOWED BY THEIRSIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.#VISUMDEVELOPMENT GROUPMAY 31, 2019 2019-008 REVISED TO ADD ADDT'L ELEC. INFO.08/03/2020ELECTRICAL SCHEDULESE002 FEEDER SCHEDULE: TWO (2) SETS OF FOUR (4) 300 MCM XHHW-AL IN 3" RMC 1/0-1/0-1/0-2 AL SER CABLE, TYP OF ALL APARTMENT FEEDS 2-2-2-4 AL SER CABLE A B C UNITS 301 - 304 PANELS P301 - P304 125A MLO 120/240V 1PH-3W 24-SP UNITS 201 - 204 PANELS P201 - P204 125A MLO 120/240V 1PH-3W 24-SP UNITS 101 - 104 PANELS P101 - P104 125A MLO 120/240V 1PH-3W 24-SP HOUSE PANEL 125A MLO 120/240V; 1PH-3W; 24-SP SQD QO124L125PG 4-POSITION METER BRANCH: 125A RESIDENTIAL TYPE W/O BYPASS; 125A-2P BREAKER FOR EACH APARTMENT FEED; SQD EZM114125; TYP. OF 2 5-POSITION METER BRANCH: 125A RESIDENTIAL TYPE W/O BYPASS; 125A-2P BREAKER FOR EACH APARTMENT FEED; SQD EZM115125 PROVIDE 125A-2P BREAKER FOR HOUSE PANEL FEED UNDERGROUND SERVICE FROM UTILITY POLE, SEE SITE PLAN RESIDENCES (1ST FLOOR) MECHANICAL ROOM (1ST FLOOR) RESIDENCES (2ND FLOOR) RESIDENCES (1ST FLOOR) RESIDENCES (3RD FLOOR) RESIDENCES (2ND FLOOR) A C B ELECTRICAL POWER RISER DIAGRAM SCALE: 12" = 1'-0"1 B B B B B B B B B B B PANEL LAYOUTS FOR UNITS 102, 103, 202, 203, 302, 303 SCALE: N.T.S.2 400A MAIN SERVICE DISCONNECT 400A CIRCUIT BREAKER 120/240 VAC, 1PH-3W (SQD EZM3400CBU) PANEL LAYOUTS FOR UNITS 101, 104, 201, 204, 301, 304 SCALE: N.T.S.3 HOUSE PANEL LAYOUT SCALE: N.T.S.4 EQUIPMENT SCHEDULE DESCRIPTION QTY.MANUFACTURER MODEL TYPE/SIZE COLOR WALL HEATER 14 CADET CSC101TW IN-WALL, 1,000-WATT, 120V WHITE WATER HEATER 12 RHEEM EGSP20 20 GAL., 1,500-WATT, 120V VENTILATION FAN 12 BROAN LP50100DC 50/80/100 CFM CEILING BATHROOM VENT FAN WHITE BASEBOARD HEATER 12 FAHRENHEAT F2544 48-IN., 1,000-WATT, 240V WHITE BASEBOARD HEATER 18 FAHRENHEAT F25408 96-IN., 2,500-WATT, 240V WHITE UNIT CEILING LIGHTS COMMERCIAL ELECTRIC NS01aA11FR1-2 59 5/6 IN. INTEGRATED LED RECESSED FIXTURE WHITE MECH. ROOM LIGHTS 2 COMMERCIAL ELECTRIC 54283141 4 FT. 64-WATT EQ. INTEGRATED LED STRIP LIGHT FIXTURE, 4000K BRIGHT WHITE 3600 LUMENS WHITE NOTES: 1.ALL OTHER LIGHT FIXTURES PER ARCHITECT/OWNER SPECIFICATIONS. 2.CEILING FANS PER ARCHITECT/OWNER SPECIFICATIONS. 3.APPLIANCES PER ARCHITECT/OWNER SPECIFICATIONS. APPLIANCE LOAD RATINGS SHALL BE AT OR LOWER THAN THE LOAD SHEETS ON E001. INCHESDUAL DIMENSIONS: [MILLIMETERS] ADDITIONAL NOTES : WHEN USED AS SERVICE EQUIPMENT, INSTALL BONDING STRAP AND REINSTALL GROUND LUG WHERE APPROPRIATE. HANDLE EXTENSION AVAILABLE, ORDER KIT AHEXLI, HANDLE IS HINGED, ALLOWING IT TO BE TUCKED UNDER THE DOOR ON THE COVER. THIS LUG IS AVAILABLE FROM SQUARE D. ORDER CATALOG NUMBER CMELK4, KIT INCLUDES 4 LUGS. INDICATED VERSA-CRIMP CRIMPING TOOL. KNOCKOUTS MMIN CONDUIT SIZE 13 51 89 38 76 64 102 19 .50 2.00 3.50 1.50 3.00 2.50 4.00 .75 A F I E H G J B SYMBOL NOTES: 1.FINISH - GRAY BAKED ENAMEL POWDER COAT PAINT OVER CLEANED GALVANIZED STEEL. 2.UL LISTED - FILE E-10582, VOL. M, E-131840, VOL. M 3.SUITABLE FOR USE AS SERVICE EQUIPMENT. 4.MAIN HORIZONTAL CROSS BUS RATED AT 800 AMPERES. 5.MAIN DEVICES ARE SEALABLE BY UTILITY. 6.GANGABLE MULTI-METERING EQUIPMENT IS DESIGNED FOR WALL MOUNTING ONLY. (NOT SUITABLE FOR FLOOR STANDING EQUIPMENT.) 3Ø 4W 208Y/120VAC OR 240/120VAC DELTA SYSTEM TYPE 400 MAIN RATING (AMPERES) CATALOG NUMBER * EZM3400CBU MAIN CIRCUIT BREAKER (FACTORY INSTALLED) LHF36400 LINE PHASE AND NEUTRAL LUG LANDING PADS PROVIDED FOR USE WITH CRIMP-TYPE LUGS(2-HOLE MOUNTING) QUANTITY OF LUGS PER PAD. 1 (ORDER LUGS SEPARATELY)(1) #6-300 GROUND LUG WIRE RANGE (FACTORY INSTALLED) CATALOG NUMBER ALTERNATE LUG QUANTITY PER LINE SIDE PHASE AND NEUTRAL TERMINALS (ORDER SEPARATELY) ANDERSON ILSCO CMC EZM3400CBU VC-6 1 1 1 1 1 1 1 1 1 MECHMECHMECHMECHIDT-12MECHVC-8VC-7 250-600 CU VHCL- 600- 12BN VHCL- 750- 12BN 500-750 CU VACL- 1000- 12BN 750-1000 AL LID2- 600 #2-600 AL/CU 250-600 AL/CU 2ACL- 600 TA-600- 2N #2-600 AL/CU (2) #2-600 AL/CU AU-600- 2N (2 BARREL) #2-600 AL/CU A1B2- 600- 2 2AB2- 600 (2 BARREL) (2) #2-600 AL/CU SEAL BRACKET BOTTOM MOUNTING BRACKET TOP MOUNTING BRACKET E,F,G,H,I,J A,B 16.30 414 AØ LOAD BØ CØ N CIRCUIT BREAKER A Ø B Ø C Ø NEUTRAL DISCONNECT LINK LINE BOX BONDING WHEN REQUIRED GROUND WHEN REQUIRED N SERVICE GROUND LUGS WHEN REQUIRED LOAD .38 [10] .40 [10] 1.71 [43] 1.50 [38] .72 [18] .50 DIA [13] .25 DIA [6] 1.77 [45].78 [20] 1.50 [38] .38 DIA [10] .31 DIA [8] .10 X .40 SLOT [3] [10].42 DIA [11] 1.12 [28] .91 [23] 5.80 [147] TYP 4.34 [110] 3.03 [77] 11.06 [281] 20.28 [515] HANGING MOUNTING RAIL 11.50 [292] 49.37 [1254] 4.00 [102] 11.06 [281] CLOSING PLATES SUPPLIED FACTORY INSTALLED. REMOVE PRIOR TO CONNECTING BRANCH UNIT AND REINSTALL AT END OF LINE-UP. HORIZONTAL CROSS BUS SYSTEM INCLUDES EXCLUSIVE VISI-TITE JOINT-NUTS TO MAKE ALL PHASE AND NEUTRAL CONNECTIONS BETWEEN TWO EZM UNITS. NEUTRAL DISCONNECT LINK BONDING STRAP PROVIDED (FIELD INSTALL WHEN USED AS SERVICE EQUIPMENT) GROUND LUG LINE NEUTRAL LINE PHASE LUGS 20.46 [520] 16.30 [414] 3.44 [87] TYP 30.25 [768] Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø N 1.71 [43] .83 [21] .50 [13] .38 [10] 1.50 [38] 1.77 [45] 1.50 [38] .78 [20] .50 DIA [13] .25 DIA [6] .38 DIA [10] TOP MOUNTING BRACKET BOTTOM MOUNTING BRACKET EZM115125 KNOCKOUTS SYMBOL CONDUIT SIZE IN MM A .50 13 B C D E .75 1.25 1.50 1.00 19 25 32 38 A,B,C C,D,E HORIZONTAL CROSS BUS SYSTEM INCLUDES EXCLUSIVE VISI-TITE JOINT-NUTS TO MAKE ALL PHASE AND NEUTRAL CONNECTIONS BETWEEN TWO EZM UNITS. C,D,E TOP OF MOUNTING CHANNEL TENANT CIRCUIT BREAKER 125A MAX. TIGHTEN 50LB-FT. (600LB-IN.) EQUIPMENT GROUNDS AND SERVICE GROUND LOAD NEUTRALS LINE 7.09 [180] 57.12 [1451] 6.59 [167] 31.30 [795] 10.48 [266] 7.54 [192] 4.59 [117] 1.65 [42] 12.12 [308] 5.75 [146]2.44 [62] 2.72 [69] TYP 1.67 [42] 1.62 [41] 1.78 [45] 4.79 [122] 7.10 [180] 11.19 [284] 9.00 [229] TYP 12.25 [311]3.75 [95]2.21 [56] 3.44 [87] 5.20 [132] TYP 6.59 [167] 2.48 [63] SYSTEM TYPE (IN) DUAL DIMENSIONS: SERVICE PROVIDED (OUT) CATALOG NUMBER METER SOCKET TYPE NUMBER OF POSITIONS QO,QO-VH,OR QOH 125A MAX 2-POLE 51 3W 120/240VAC 4-JAW RING TYPE WITHOUT BYPASS1 3W 120/240VAC TENANT CIRCUIT BREAKER (ORDER SEPARATELY) Ø Ø LOAD NEUTRAL WIRE RANGE EQUIPMENT GROUND AND SERVICE GROUND WIRE RANGE (8) #14-2/0 AWG CU (8) #12-2/0 AWG AL (6) #14-2/0 AWG CU (6) #12-2/0 AWG AL HORIZONTAL CROSS BUS RATED 800A CONTINUOUS. (UNIT SUPPLIED WITH ALL ALUMINUM BUSSING). SUPPLIED WITH DRIP HOOD FOR USE OUTDOORS (NEMA 3R). DRIP HOOD IS REMOVABLE WHEN USED INDOORS (NEMA 1). A FACTORY INSTALLED TOP ENDWALL WITH KNOCKOUT SIMILAR TO BOTTOM ENDWALL IS SUPPLIED FOR CABLE EXITS OUT THE TOP. .32 [8] 5TH JAW OMITTED ON RING STYLE TYPE EZM UNITS IF REQUIRED ORDER ONE 5TH JAW KIT PER METER SOCKET POSITION (CATALOG NUMBER: 5J) LINE NOTES: 1.FINISH - GRAY BAKED ENAMEL POWDER COAT PAINT OVER CLEANED GALVANIZED STEEL. 2.UL LISTED - FILE E-10582, VOL. M, E-131840, VOL. M 3.SUITABLE FOR USE AS SERVICE EQUIPMENT. 4.MAIN HORIZONTAL CROSS BUS RATED AT 800 AMPERES. 5.MAIN DEVICES ARE SEALABLE BY UTILITY. 6.GANGABLE MULTI-METERING EQUIPMENT IS DESIGNED FOR WALL MOUNTING ONLY. (NOT SUITABLE FOR FLOOR STANDING EQUIPMENT.) INCHES [MILLIMETERS] Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø N 1.71 [43] .83 [21] .50 [13] .38 [10] 1.50 [38] 1.77 [45] 1.50 [38] .78 [20] .50 DIA [13] .25 DIA [6] .38 DIA [10] SYSTEM TYPE (IN) TOP MOUNTING BRACKET BOTTOM MOUNTING BRACKET DUAL DIMENSIONS:INCHES [MILLIMETERS] SERVICE PROVIDED (OUT) CATALOG NUMBER METER SOCKET TYPE NUMBER OF POSITIONS QO,QO-VH,OR QOH 125A MAX 2-POLE 41 3W 120/240VAC EZM114125 4-JAW RING TYPE WITHOUT BYPASS1 3W 120/240VAC KNOCKOUTS SYMBOL CONDUIT SIZE IN MM A .50 13 B C D E .75 125 1.50 1.00 19 25 32 38 6.59 [167] 2.44 [62] 2.72 [69] TYP 1.67 [42] 1.62 [41] 1.78 [45] 5.75 [146] 12.12 [308] A,B,C C,D,E HORIZONTAL CROSS BUS SYSTEM INCLUDES EXCLUSIVE VISI-TITE JOINT-NUTS TO MAKE ALL PHASE AND NEUTRAL CONNECTIONS BETWEEN TWO EZM UNITS. C,D,E 31.30 [795] 48.12 [1222] 6.59 [167] 3.75 [95] 12.25 [311] 2.21 [56] 3.44 [87] 5.20 [132] TYP 11.19 [284] 9.00 [229] TYP 10.48 [266] 7.54 [192] 4.59 [117] 1.65 [42] 2.48 [63] 4.79 [122] 7.10 [180] TOP OF MOUNTING CHANNEL TENANT CIRCUIT BREAKER 125A MAX. TIGHTEN 50LB-FT. (600LB-IN.) EQUIPMENT GROUNDS AND SERVICE GROUND LOAD NEUTRALS LINE TENANT CIRCUIT BREAKER (ORDER SEPARATELY) Ø Ø LOAD NEUTRAL WIRE RANGE EQUIPMENT GROUND AND SERVICE GROUND WIRE RANGE (7) #14-2/0 AWG CU (7) #12-2/0 AWG AL (5) #14-2/0 AWG CU (5) #12-2/0 AWG AL 5TH JAW OMITTED ON RING STYLE TYPE EZM UNITS IF REQUIRED ORDER ONE 5TH JAW KIT PER METER SOCKET POSITION (CATALOG NUMBER: 5J) HORIZONTAL CROSS BUS RATED 800A CONTINUOUS. (UNIT SUPPLIED WITH ALL ALUMINUM BUSSING). 7.09 [180]SUPPLIED WITH DRIP HOOD FOR USE OUTDOORS (NEMA 3R). DRIP HOOD IS REMOVABLE WHEN USED INDOORS (NEMA 1). A FACTORY INSTALLED TOP ENDWALL WITH KNOCKOUT SIMILAR TO BOTTOM ENDWALL IS SUPPLIED FOR CABLE EXITS OUT THE TOP. .32 [8] LINE NOTES: 1.FINISH - GRAY BAKED ENAMEL POWDER COAT PAINT OVER CLEANED GALVANIZED STEEL. 2.UL LISTED - FILE E-10582, VOL. M, E-131840, VOL. M 3.SUITABLE FOR USE AS SERVICE EQUIPMENT. 4.MAIN HORIZONTAL CROSS BUS RATED AT 800 AMPERES. 5.MAIN DEVICES ARE SEALABLE BY UTILITY. 6.GANGABLE MULTI-METERING EQUIPMENT IS DESIGNED FOR WALL MOUNTING ONLY. (NOT SUITABLE FOR FLOOR STANDING EQUIPMENT.) QO124L125PG 125 3424 KNOCKOUTS 1.00 C 25 1.25 2.502.001.50 D GFE 32 645138 .75 B 19 .50 A 13 IN MM SYMBOL CATALOG NUMBER MAXIMUM SYSTEM VOLTAGE MAINS AMPERE RATING SPACES MAXIMUM NUMBER OF SINGLE POLE CIRCUITS MAIN WIRE SIZE AWG AL/CU 120/240VAC 1Ø 3W #6-2/0 20.92 [531] 18.06 [459] 1.43 [36] 5.50 [140] 3.75 [95] 14.25 [362] .44 DIA [11] (4 HOLES) C,D,E,F,G B,C,D,E B,C,D,E A,B,C,D A A,B C,D,E,F A B,C,D,E A,B (4 HOLES)R.25 [6] R.14 [4] .47 [14] 2.10 [53].57 [14] LINE LINE4.38 [111] S S N N QO124L125PG QO124L125PGC NOTES: 1.FINISH - GRAY BAKED ENAMEL ELECTRODEPOSITED OVER CLEANED PHOSPHATIZED STEEL. 2.UL LISTED - FILE E-6294 3.NEUTRALS - INSULATED GROUNDABLE. 4.LOAD CENTERS WITH "G" IN CATALOG NUMBER INCLUDE A FIELD INSTALLABLE EQUIPMENT GROUND BAR KIT. 5.LOAD CENTERS WITH "P" IN CATALOG NUMBER INCLUDE EXTENDED NEUTRALS FOR PLUG ON NEUTRAL READY INTERIORS. 6.LOAD CENTERS WITH "C" IN CATALOG NUMBER INCLUDE FLUSH/SURFACE MOUNTED COVER. B,C,D,E PROJECT NO.PROJECT:TITLE OF DRAWINGDRAWING NO. FIRST ISSUE DATE:0ISSUED/REVISIONS:DATE:123456ENGINEER:OWNER/DEVELOPER:112 N. MAIN ST.HORSEHEADS, NY 14845607-377-7990 | WWW.MASER-AE.COM119 S. CAYUGA STREETITHACA, NY 14850327 W. SENECA ST.ITHACA, NEW YORK 14850327 W. SENECA STREETA 5 4 3 2 16 B C D E A B C D E 78 5 4 3 2 1678 ISSUED FOR PERMIT08/19/2019REVISED FOR MECH. RM. EQUIP.06/04/20203-STORY, 12-UNIT APARTMENT BUILDINGREVISED FOR CONSTRUCTION06/17/2020DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT,ENGINEER, SURVEYOR OR LANDSCAPEARCHITECT TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THISDOCUMENT IS REQUIRED BY LAW TOAFFIX THEIR SEAL AND THE NOTATION,"ALTERED BY," FOLLOWED BY THEIRSIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.#VISUMDEVELOPMENT GROUPMAY 31, 2019 2019-008 REVISED TO ADD ADDT'L ELEC. INFO.08/03/2020ELECTRICAL DETAILSE003FIVE POSITION METER BRANCH (SQUARE D) SCALE:N.T.S3 400A MAIN SERVICE DISCONNECT DETAIL (SQUARE D) SCALE: N.T.S1 FOUR POSITION METER BRANCH (SQUARE D) SCALE:N.T.S4 TYPICAL UNIT POWER PANEL (SQUARE D) SCALE:N.T.S2 GFI/6 16/18 20/GFI 15 9 2 1 1 ALL STAIR ENTRY, STAIR, AND CORRIDOR LIGHTING TO REMAIN ON AT ALL TIMES AND CIRCUITED TO EMERGENCY PANELBOARD IN MECH.RM. S S S S S S S S S S S DW DW DW DW UP MECH. CLO. MECH. MECH. CLO. BEDROOM 2 BEDROOM 1 LIVING/ DINING BATH BATH BATH LIVING/ DINING CLO. BATH CLO. KITCHENCLO. REF. KITCHEN SLEEPING CLO. SLEEPING KITCHEN LIVING/ DINING LIVING/ DINING KITCHEN REF. REF.REF. STAIR ENTRY STAIRWELL W/DW/D W/D W/D WH WH RANGE RANGERANGE RANGE WH WHGFIS T T T GFI/22 9 9 11 13 13 13 13 17/19 17/19 17/19 17/19 17/19 17/19 17/19 17/19 15 15 17/19 11 11 11 15 1 2 7GFI/5 5 7 2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 GFI/6GFI/610 12/14 8 2/3-WAY 2/3-WAY 2/3-WAY 1 1 BEDROOM 2 BEDROOM 1 2 2 2 2 2 2 2/3-WAY 2 2 2 2 GFI/6 8 12/14 10GFI/6 GFI/6 20/GFI 9 13 11 15 15 13 T 17/19 T 17/19 9 9 9 11 11 11 15 13 4 4 4 4 4 4 GFI/22 2/3-WAY 4 16/18 2 GFI/5 5 1 1 12 1 17/19T 2 2/3-WAY 17/19 T17/19 2 1 1 2 7 GFI/5 5 1 1 1 1 2 1 1 2 7 GFI/5 5 1 1 1 1 9 9 9 9 9 16/18 16/18 13 20/GFI 20/GFI GFI/22 GFI/22 2 2 2 222 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2/2-WAY 10 GFI/6GFI/6 12/148 4 4 4 4 2/2-WAY 11 11 11 11 11 11 11 11 11 1117/19 T17/19 17/19 17/19T 11 11 9 9 9 9 99 17/19T 17/19 4 4 4 4 2 10GFI/6 GFI/612/14 8 2 1 1 1 1 1 1 1111111 3 3 3 3 33 3 PROJECT NO.PROJECT:TITLE OF DRAWINGDRAWING NO. FIRST ISSUE DATE:0ISSUED/REVISIONS:DATE:123456ENGINEER:OWNER/DEVELOPER:112 N. MAIN ST.HORSEHEADS, NY 14845607-377-7990 | WWW.MASER-AE.COM119 S. CAYUGA STREETITHACA, NY 14850327 W. SENECA ST.ITHACA, NEW YORK 14850327 W. SENECA STREETA 5 4 3 2 16 B C D E A B C D E 78 5 4 3 2 1678 ISSUED FOR PERMIT08/19/2019REVISED FOR MECH. RM. EQUIP.06/04/20203-STORY, 12-UNIT APARTMENT BUILDINGREVISED FOR CONSTRUCTION06/17/2020DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT,ENGINEER, SURVEYOR OR LANDSCAPEARCHITECT TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THISDOCUMENT IS REQUIRED BY LAW TOAFFIX THEIR SEAL AND THE NOTATION,"ALTERED BY," FOLLOWED BY THEIRSIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.#VISUMDEVELOPMENT GROUPMAY 31, 2019 2019-008 REVISED TO ADD ADDT'L ELEC. INFO.08/03/2020FIRST FLOOR UNITS 101 - 104 SCALE: 38" = 1'-0"1 400A MAIN SERVICE DISCONNECT 4-POS. METER BRANCH 125A HOUSE PANEL 5-POS. METER BRANCH WALL HEATER FIRST FLOOR ELECTRICAL PLANE101 UNIT 101 UNIT 102 UNIT 103 UNIT 104 TYP. 8-FT. BASEBOARD HEAT UNIT TYP. 4-FT. BASEBOARD HEAT UNIT TYP. 4-FT. BASEBOARD HEAT UNIT TYP. POWER PANEL DW DW DW DW UP REF. REF.REF. REF. W/DW/D W/D W/D WH WHWH WH RANGE RANGERANGE RANGE GFI/6 15 9 S S S T T T 9 9 11 13 13 13 13 17/19 17/19 17/19 17/19 17/19 15 15 17/19 11 11 11 15 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 GFI/6GFI/610 12/14 8 2/3-WAY 2/3-WAY 2/3-WAY 4 16/18 20/GFI 2 2 GFI/22 2 1 1 7 1 1 2 GFI/5 5 9 2 1 1 2 1 7 1 5 GFI/5 T 4 17/19 GFI/22 17/19 2 2 2 2 2 2 4 2/3-WAY 44 S GFI/6 8 12/14 10GFI/6 GFI/6 2 2 2 16/18 20/GFI 2 2 2 2 2/3-WAY 2 S S 17/19 17/19 9 13 11 15 15 13 T 17/19 T 17/19 9 9 9 11 11 11 15 13 13 15 S 2 1 1 2 7 GFI/5 511 16/18 20/GFI 2 2 2 2/2-WAY 10 GFI/6GFI/6 12/148 9 9 9 11 17/19 T 17/19 17/19 17/19T 2 2 2 2 2 2 11 9 11 GFI/22 2/2-WAY 4 4 9 2 2 2 9 9 11 2 2 2 17/19 T17/19 2/2-WAY 4 17/19 17/19 T 11 11 9 4 11 9 9 1 1 2 1 2 7 1 GFI/5 5 16/18 20/GFI 2 2 2 S 8 GFI/6GFI/6 12/1410 11 GFI/22 PROJECT NO.PROJECT:TITLE OF DRAWINGDRAWING NO. FIRST ISSUE DATE:0ISSUED/REVISIONS:DATE:123456ENGINEER:OWNER/DEVELOPER:112 N. MAIN ST.HORSEHEADS, NY 14845607-377-7990 | WWW.MASER-AE.COM119 S. CAYUGA STREETITHACA, NY 14850327 W. SENECA ST.ITHACA, NEW YORK 14850327 W. SENECA STREETA 5 4 3 2 16 B C D E A B C D E 78 5 4 3 2 1678 ISSUED FOR PERMIT08/19/2019REVISED FOR MECH. RM. EQUIP.06/04/20203-STORY, 12-UNIT APARTMENT BUILDINGREVISED FOR CONSTRUCTION06/17/2020DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT,ENGINEER, SURVEYOR OR LANDSCAPEARCHITECT TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THISDOCUMENT IS REQUIRED BY LAW TOAFFIX THEIR SEAL AND THE NOTATION,"ALTERED BY," FOLLOWED BY THEIRSIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.#VISUMDEVELOPMENT GROUPMAY 31, 2019 2019-008 REVISED TO ADD ADDT'L ELEC. INFO.08/03/2020SECOND FLOOR UNITS 201 - 204 SCALE: 38" = 1'-0"1 SECOND FLOOR ELECTRICAL PLANE102 UNIT 201 UNIT 202 UNIT 203 UNIT 204 TYP. 8-FT. BASEBOARD HEAT UNIT TYP. 4-FT. BASEBOARD HEAT UNIT TYP. POWER PANEL DW DW DW DW UP REF. REF. REF. REF. W/DW/D W/D W/D WH WHWH WH RANGE RANGERANGE RANGE GFI/6 15 9 S S S T T T 9 9 11 13 13 13 13 17/19 17/19 17/19 17/19 17/19 15 15 17/19 11 11 11 15 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 GFI/61012/14 8 2/3-WAY 2/3-WAY 2/3-WAY 4 16/18 20/GFI 2 2 GFI/22 2 1 1 7 1 1 2 GFI/5 5 9 2 1 1 2 1 7 1 5 GFI/5 T 4 17/19 GFI/22 17/19 2 2 2 2 2 2 4 2/3-WAY 44 S GFI/6 8 12/14 10GFI/6 GFI/6 2 2 2 16/18 20/GFI 2 2 2 2 2/3-WAY 2 S S 17/19 17/19 9 13 11 15 15 13 T 17/19 T 17/19 9 9 9 11 11 11 15 13 13 15 2 1 1 2 7 GFI/5 511 16/18 20/GFI 10 GFI/6GFI/6 12/148 2 GFI/22 S 2 2 2 2/2-WAY 9 9 9 11 17/19 T 17/19 17/19 17/19T 2 2 2 2 2 11 9 11 2/2-WAY 4 4 9 11 2 2 2 9 9 11 2 2 2 17/19 T17/19 2/2-WAY 4 17/19 17/19 T 11 11 9 4 9 9 1 1 2 1 2 7 1 GFI/5 5 16/18 20/GFI 2 2 2 S 8 GFI/6GFI/6 12/1410 11 GFI/22 PROJECT NO.PROJECT:TITLE OF DRAWINGDRAWING NO. FIRST ISSUE DATE:0ISSUED/REVISIONS:DATE:123456ENGINEER:OWNER/DEVELOPER:112 N. MAIN ST.HORSEHEADS, NY 14845607-377-7990 | WWW.MASER-AE.COM119 S. CAYUGA STREETITHACA, NY 14850327 W. SENECA ST.ITHACA, NEW YORK 14850327 W. SENECA STREETA 5 4 3 2 16 B C D E A B C D E 78 5 4 3 2 1678 ISSUED FOR PERMIT08/19/2019REVISED FOR MECH. RM. EQUIP.06/04/20203-STORY, 12-UNIT APARTMENT BUILDINGREVISED FOR CONSTRUCTION06/17/2020DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT,ENGINEER, SURVEYOR OR LANDSCAPEARCHITECT TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THISDOCUMENT IS REQUIRED BY LAW TOAFFIX THEIR SEAL AND THE NOTATION,"ALTERED BY," FOLLOWED BY THEIRSIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.#VISUMDEVELOPMENT GROUPMAY 31, 2019 2019-008 REVISED TO ADD ADDT'L ELEC. INFO.08/03/2020THIRD FLOOR UNITS 301 - 304 SCALE: 38" = 1'-0"1 THIRD FLOOR ELECTRICAL PLANE103 UNIT 301 UNIT 302 UNIT 303 UNIT 304 TYP. 8-FT. BASEBOARD HEAT UNIT TYP. 4-FT. BASEBOARD HEAT UNIT TYP. POWER PANEL