HomeMy WebLinkAbout2018015 - 327 W Seneca Street - 06.22.2020 - Revision 1Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
DESIGN TEAM
STREAM Collaborative
Architecture & Landscape Architecture DPC
Noah Demarest RA, RLA, LEED AP
ph: 607.216.8802
noah@streamcolab.com
ELWYN+PALMER Consulting Engineers
MARATHON Engineering
A
1
2
3
4
BCD6/22/2020 10:09:14 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA000
COVER SHEET
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
327 W. SENECA STREET
VISUM DEVELOPMENT
CITY OF ITHACA, NY
DRAWING LIST
SHEET DRAWING NAME
00 - GENERAL
A000 COVER SHEET
01 - CIVIL
C1.0 SANITARY LATERAL PLAN
02 - LANDSCAPE
L001 SITE LAYOUT PLAN AND PLANTING PLAN
L002 UTILITY PLAN AND WORK ZONE PLAN
L003 GRADING PLAN
L501 SITE DETAILS
L502 BIKE SHED
03 - ARCHITECTURE
A101 FIRST FLOOR PLAN
A102 SECOND FLOOR PLAN
A103 THIRD FLOOR PLAN
A104 ROOF PLAN
A105 FIRST FLOOR ELECTRIC PLAN
A106 SECOND FLOOR ELECTRIC PLAN
A107 THIRD FLOOR ELECTRIC PLAN
A201 ELEVATION - WEST
A202 ELEVATION - EAST
A203 ELEVATIONS- NORTH/ SOUTH
A204 ENLARGED PLANS AND INTERIOR ELEVS
A301 SECTIONS
A302 SECTIONS
A401 DETAILS
A501 DETAILS
A502 WINDOW DETAILS
A601 SCHEDULES
04 - STRUCTURAL
S001 GENERAL NOTES
S100 EXISTING BUILDING FOUNDATION DEMO PLAN
S101 FOUNDATION PLAN
S300 FOUNDATION DETAILS
05 - ELECTRICAL
E100 ELECTRIC RISER DIAGRAM
VICINITY MAP
REVISIONS
Δ DESCRIPTION DATE
AVERAGE LOT DEPTH 88.71'EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDING
PUBLIC SIDEWALK
WEST SENECA STREET
87° 34' 30"
52.00'
N E
2° 09' 56"90.29'SE87° 44' 38"
26.94'
S W2° 13' 55"87.42'NW87° 59' 37"
25.01'
S W
PROPOSED 3-STORY APARTMENT
327 W. SENECA ST.
LAWN
NEW LAWN
EXISTING CITY TREES TO REMAIN
HBA
4
TOS
1
TOS
1
HBA
4
TOS
1
HMA
3
HBA
2
TOS
1
HBA
2
TOS
1
HMA
3
CFD
2
LAWN LAWNLAWN
LAWNBIKE SHEDBZA APPROVED SETBACK10'TRASH CAN ENCLOSURENEW WALKMAIL
AVERAGE LOT DEPTH 88.71'NEW WALKBIKE SHEDWEST SENECA STREET
EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDING EXISTING EXIT DOOR
EXISTING SIDEWALK
NEW SIDEWALK
7.05'PROPOSED 3-STORY
APARTMENT
327 W. SENECA ST.
NEW CURB
CURB CUT TO BE REMOVED
6.55' ±8.84' ±CANOPY
CANOPY
CANOPIES
BIKE RACK
PUBLIC SIDEWALK
EXISTING EGRESS WALKWAY
EXISTING PARKING LOT
REQUIRED SETBACK13.3'1' BZA APPROVED SETBACK3' BZA APPROVED SETBACK6' BZA APPROVED SETBACK
10.08'
10' REQUIRED SETBACK
5' REQUIRED SETBACK
36.83'10.59'10' REQUIRED SETBACK23'-10"8'-0"21'-6"5'-0"12'-4"27'-6"15'-0"28'-6"4'-0"
9'-1"5'-0"22'-9"11'-10"4'-1"6'-8"
COVERED WOOD
BIKE SHED
(ACCESSORY
STRUCTURE) ±8'-0"
HIGH 4'-0"4'-0"
4'-0"
L501
D3
4'-0"
ASPHALT PATCH
EXISTING BUILDING
TO BE DEMOLISHED
BY OWNER.
SEE DWG S100.
EXG. CMU PRIVACY WALL TO
BE DEMOLISHED BY OWNER.
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1" = 10'-0"6/12/2019 3:31:12 PMC:\Users\Steven\Documents\2018015 - 327 W.Seneca Street - Site_stevenPUFGL.rvtL001
SITE PLAN AND
PLANTING PLAN
2018015327 WEST SENECA ST.06/18/2019VISUM DEVELOPMENTCITY OF ITHACA, NYDESIGN DEVELOPMENT
1" = 10'-0"D1 PLANTING PLAN
1" = 10'-0"C1 SITE LAYOUT PLAN
N
PLANTING SCHEDULE
KEY QTY. BOTANICAL NAME COMMON NAME INSTALLED SIZE MATURE SIZE COMMENTS
SHRUB - PERENNIAL
HMA 6 Hakonechloa macra 'Aureola' Golden Japanese Forest Grass #1 CONTAINER 1.5' TALL & WIDE SHADE TOLERANT
HBA 12 Hosta x 'Blue Angel' Blue Angel Plantain Lily #1 CONTAINER 4' WIDE SHADE TOLERANT
TREE - ORNAMENTAL
CFD 2 Cornus florida Flowering Dogwood 2" CALIPER 25' TALL
TREE -EVERGREEN
TOS 5 Thuja occidentalis 'Skybound' Skybound Arborvitae 6 FEET TALL 15-20' TALL COLUMNAR
GENERAL SHEET NOTES - PLANTING
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 Consult landscape architect on shape of bed edge and placement of all plants prior to installation.
3 Only nursery-grown plant materials shall be acceptable. All trees, shrubs and ground covers shall comply with
applicable requirements of ANSI z60.1, American standard for nursery stock.
4 All planting beds to be excavated to a minimum depth of two feet and replaced with amended topsoil consisting of
1 part screened topsoil, 1 part compost and 1 part sand.
5 Tree pits in lawn to be excavated to depth of root ball plus six inches and shall be three times the width of the root
ball.
6 Deciduous trees shall have a caliper of at least 2 1/2 inches at breast height (DBH) at the time of planting.
7 All trees in lawn areas to receive five-foot diameter mulch rings.
8 Install 3 inches of natural shredded bark mulch in all planting beds.
9 No plants or trees shall be located beneath building overhangs.
10 Sun/shade lawn mix - deep till any compaction due to construction and install 4" of amended topsoil.
11 Warranty all plant materials for a period of 1-year beyond the date of substantial completion.
GENERAL SHEET NOTES - SITE LAYOUT
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 General contractor shall notify all utility owners having underground utilities on site prior to excavation.
Contractor shall contact utility locating company and locate all utilities prior to any excavation.
3 See civil drawings for layout of underground utilities.
4 See electrical drawings for layout of underground electrical and lighting.
5 Install expansion joints every 30' in concrete and in areas where concrete abuts curbs and other fixed objects.
6 Verify dimensions and accept conditions before proceeding with work. Report discrepancies to landscape
architect before proceeding.
7 Do not scale drawings.
8 Walks, drives, curbs, parking, and building locations to be laid out in the field by a licensed surveyor.
9 Dimensions to curbs are to exposed faces unless otherwise noted.
N
REVISIONS
Δ DESCRIPTION DATE
WEST SENECA STREET
EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDING
PUBLIC SIDEWALK
PROPOSED 3-STORY APARTMENT
327 W. SENECA ST.
O.H.O.H.
O.H.
SAN
*SEE CIVIL DWGS FOR
SAN CONNECTION
W SAN
W
WW
E
MECHANICAL ROOM
WEST SENECA STREET
EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDING
EXISTING EXIT DOOR
EXISTING SIDEWALK
PUBLIC SIDEWALK
PROPOSED 3-STORY APARTMENT
327 W. SENECA ST.
ACCESS TO BE MAINTAINED THROUGH
NEGOTIATION W/ ADJACENT PROPERTY
OWNERS DURING CONSTRUCTION
TEMPORARY CONSTRUCTION
FENCE AT PROPERTY LINE
MAINTAIN ACCESS TO
ADJACENT PROPERTIES
TEMPORARY CONSTRUCTION
FENCE AT PROPERTY LINE
STAGING AREA. STREET PERMIT TO BE ACQUIRED
PUBLIC SIDE WALK TO BE CLOSED DURING
CONSTRUCTION. PROVIDE SIDEWALK
DETOUR SIGNAGE AS REQUIRED BY CITY
EXISTING EGRESS WALKWAY
EXISTING PARKING LOT
TREE PROTECTION. 6'-0" TALL, 5'-0" x 12'-0"
CHAIN LINK FENCE. REPLACE TREES IF THEY
ARE DAMAGED OR DIE WITHIN ONE YEAR
OF CONSTRUCTION
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1" = 10'-0"6/12/2019 3:31:16 PMC:\Users\Steven\Documents\2018015 - 327 W.Seneca Street - Site_stevenPUFGL.rvtL002
UTILITY PLAN AND
WORK ZONE PLAN
2018015327 WEST SENECA ST.06/18/2019VISUM DEVELOPMENTCITY OF ITHACA, NYDESIGN DEVELOPMENT
1" = 10'-0"B1 UTILITY PLAN
1" = 10'-0"D1 WORK ZONE TRAFFIC CONTROL PLAN
NN
REVISIONS
Δ DESCRIPTION DATE
1 Revision 1 Date 1
TRASH CAN ENCLOSUREAVERAGE LOT DEPTH 88.71'BIKE SHEDWEST SENECA STREET
EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDING
EXISTING EXIT DOOR
EXISTING SIDEWALK
PROPOSED 3-STORY
APARTMENT
327 W. SENECA ST.
NEW CURB
CURB CUT TO BE REMOVED
PUBLIC SIDEWALK
EXISTING EGRESS WALKWAY
EXISTING PARKING LOT
6'-8 1/8"
ASPHALT PATCH
396.39
396.62 396.58
396.63 396.59
396.64396.5
396.65396.51
396.59
396.65396.65 396.5 397
396.58
396.61
396.65
396.65 396.61
1%
396.61396.61
396.64 396.64
396.47
396.65
396.65
396.5
396.38
396.39
396.25 396.18
FFE 396.62'
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1" = 10'-0"6/12/2019 3:31:18 PMC:\Users\Steven\Documents\2018015 - 327 W.Seneca Street - Site_stevenPUFGL.rvtL003
GRADING PLAN
2018015327 WEST SENECA ST.06/18/2019VISUM DEVELOPMENTCITY OF ITHACA, NYDESIGN DEVELOPMENT
1" = 10'-0"B1 GRADING PLAN
GENERAL SHEET NOTES - SITE LAYOUT
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 General contractor shall notify all utility owners having underground utilities on site prior to excavation.
Contractor shall contact utility locating company and locate all utilities prior to any excavation.
3 See civil drawings for layout of underground utilities.
4 See electrical drawings for layout of underground electrical and lighting.
5 Install expansion joints every 30' in concrete and in areas where concrete abuts curbs and other fixed objects.
6 Verify dimensions and accept conditions before proceeding with work. Report discrepancies to landscape
architect before proceeding.
7 Do not scale drawings.
8 Walks, drives, curbs, parking, and building locations to be laid out in the field by a licensed surveyor.
9 Dimensions to curbs are to exposed faces unless otherwise noted.
REVISIONS
Δ DESCRIPTION DATE
CONCRETE SLAB
6 X 6 X W1.4 X W1.4 MESH, FLAT SHEETS
ONLY SET ON CHAIRS
COMPACTED SUBBASE
COMPACTED SUBGRADE
NOTES
1. SEE PLANS FOR TOOL JOINTS (TJ),
EXPANSION JOINTS (EJ), LAYOUT WIDTHS,
RADII AND FINISHES
2. 2" MINIMUM CONCRETE COVERAGE ON
MESH AND TIES
8"5"WIDTH AS SHOWN ON PLAN
CROSS SLOPE AS SHOWN
ON GRADING PLAN
CONCRETE SLAB
(2) 6 X 6 X W2.9 X W2.9, 2" MIN. CLR.
TOP AND BOTTOM
COMPACTED SUBBASE
COMPACTED SUBGRADE
NOTES
1. SEE PLANS FOR TOOL JOINTS (TJ),
EXPANSION JOINTS (EJ), LAYOUT WIDTHS,
RADII AND FINISHES
2. 2" MINIMUM CONCRETE COVERAGE ON
MESH AND TIES
1'-0"8"WIDTH AS SHOWN ON PLAN
CROSS SLOPE AS SHOWN
ON GRADING PLAN
NOTES
1. TOOL JOINTS EVERY 5'-0" MAX TYPICAL OR EQUALLY
SPACED BETWEEN SITE FEATURES.
2. EXPANSION JOINTS ARE REQUIRED EVERY 50' AND AT
FIXED FEATURES LIKE BUILDINGS, LIGHT POSTS, PADS, ETC.
3. OVERLAP MESH SHEETS 1'-0" MIN
1/2" EXPANSION JOINT (EJ) AND
JOINT SEALANT
1/2" S.S. DOWEL x24" W/ PLASTIC
SLEEVE AT 18" O.C.
CONCRETE WALK
COMPACTED SUBBASE
COMPACTED SUBGRADE
1' DEEP TOOL JOINT (TJ)
W/ 1/4" RADIUS
MEDIUM BROOM FINISH
WIDTH AS SHOWN ON PLANWIDTH AS SHOWN ON PLANNOTES
1. BROOM PERPENDICULAR TO LINE OF
TRAFFIC
TOOLED EDGE AROUND EACH SCORE
JOINT AND EACH EXPANSION JOINT
2"
SUBBASE COURSE MATERIAL, TYPE
4
SOIL STABILIZATION FABRIC
SAW-CUT AND 2" DEEP MILL
12" WIDE BOTH SIDES PRIOR TO
INSTALLING ASPHALT TOP COURSE
TACK COAT
EXISTING PAVEMENT
PAVEMENT RECONSTRUCTION
OR FULL DEPTH MILLING
1'-0"
SEAM SEALER MUST BE APPLIED TO
ALL JOINTS
GRAVEL BACKFILL PER TRENCH DETAIL
NOTES:
1. PRIOR TO DEMOLITION ADJACENT ASPHALT MUST BE SAW-CUT FULL DEPTH OF
PAVEMENT
2. TACK COAT MUST BE APPLIED TO ALL HORIZONTAL AND VERTICAL SEEMS PRIOR TO
PLACEMENT OF TOP-COURSE
NYSDOT TYPE 7 TOP COURSE
ITEM 403.198902
NYSDOT TYPE 3 BINDER
ITEM 403.138902
2"3"1'-0"BIKE RACK PER MANUFACTURER
INSTALLATION INSTRUCTIONS
CORE INTO PAVERS AND CONCRETE, FILL
WITH POR-ROK OR EPOXY GROUT, SET
RACK LEVEL TO GRADE
CONCRETE PAVEMENT
PITCH 1:12 MAX
PITCH 1:12
PLAN
CONCRETE
OR PAVERS
WHERE
SHOWN PLANTING WHERE
SHOWN DROP CURB
DETECTABLE WARNING PLATES
ISOMETRIC VIEW
PITCH 1:12
1 12
1
12
6' - 0" TYP6' TYP
6' TYP
8' TYP
6' TYP NOTES
1. SEE LAYOUT PLAN FOR
LOCATION OF CURB PLANKS
2. GRADE CHANGES TO BE
SMOOTH AND EVENLY PITCHED
3. INSTALL DETECTABLE WARNING
PLATES AS PER
MANUFACTURER'S WRITTEN
INSTRUCTIONS
2" SINGLE GROUND
HARDWOOD BARK MULCH
PLANTING MIX -TOPSOIL (1 PART),
COMPOST (1 PART), SAND (1 PART)
5'-0"
SPADED EDGE -TYPICAL
COMPACTED PLANTING MIX
BENEATH ROOT BALL TO
PREVENT SETTLING
3X ROOT BALLROOT BALL + 6"2"-3" SINGLE GROUND
HARDWOOD BARK MULCH
PLANTING MIX -TOPSOIL (1
PART), COMPOST (1 PART),
SAND (1 PART)
4" TOPSOIL FOR LAWNS
SPADED EDGE -TYPICAL
1'-6" MINCOMPACTED PLANTING MIX
BENEATH ROOT BALL TO
PREVENT SETTLING
METAL LANDSCAPE
EDGING, STAKED
EXTERIOR WALL &
FINISH PER WALL TYPE
4"31 23 00.B1
6"31 05 19.A1
LAYER OF GEOTEXTILE PER MANUF
RECOMMENDATIONS
PAVER AS SELECTED BY ARCHITECT
1" SAND SETTING
COMPACTED SUBBASE
PERFORATED DRAINAGE PIPE OUT TO DAYLIGHT
6" CONCRETE BASE
ADJACENT
PAVING GRANITE CURB 1/2" BATTERED FACE, 6"
DOWN FROM SAWN TOP
ADJACENT PAVING OR PLANTING
3000 PSI CONCRETE BACKING FULL LENGTH
OF CURB, FORCE CONCRETE THROUGH BACK
OF JOINTS, GROUT FRONT AND TOP OF JOINTS
FLUSH W/ 1:2 MORTOR MIX
1:3:6 DRY MIX
UNIFORM PILES AT EACH END AND ON 3 FOOT
CENTERS BENEATH CURB FOR FULL LENGTH OF
CURB
NOTES
RADIUS CURBING SHALL BE USED ON ALL
RADII LESS THAN 100 FEET.6 1/8"1'-4 1/4"3"1'-3" MIN.4"1'-0"2'-8"4X4 LARCH
WOOD POSTS
12" DRY PACKED
CEMENT
1'-0"
1X6 LARCH
WOOD
4'-0"#1 WASHED
GRAVEL
ELEVATION SECTION
NOTE:
SEAL POST W/ ROOFING CEMENT
BELOW GRADE LEAVING END GRAIN
UNSEALED5'-6"3 1/2"6'-6"3 1/2"
1X3 LARCH
WOOD
LATCH, SEE SPEC
HINGE AT INT.
FACE, SEE SPEC
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
As indicated6/12/2019 3:31:20 PMC:\Users\Steven\Documents\2018015 - 327 W.Seneca Street - Site_stevenPUFGL.rvtL501
SITE DETAILS
2018015327 WEST SENECA ST.06/18/2019VISUM DEVELOPMENTCITY OF ITHACA, NYDESIGN DEVELOPMENT
1" = 1'-0"A2 TYPICAL LIGHT DUTY CONCRETE WALK
1" = 1'-0"B2 TYPICAL HEAVY DUTY CONCRETE WALK
1" = 1'-0"C3 TYPICAL CONCRETE JOINTS
1/2" = 1'-0"B3 TYPICAL CONCRETE BROOM FINISH
1" = 1'-0"B1 TYPICAL ASPHALT PATCH DETAIL
1/2" = 1'-0"C1 BIKE RACK
1/4" = 1'-0"A1 CURB RAMP - TYPE A
1/2" = 1'-0"D2 TYPICAL TREE PLANTING
1/2" = 1'-0"D1 TYPICAL PERENNIAL PLANTING
1 1/2" = 1'-0"C2 GRAVEL MULCH AT BUILDING PERIMETER
1" = 1'-0"B6 TYPICAL PAVER DETAIL
1" = 1'-0"B4 GRANITE CURB
1/2" = 1'-0"D3 TRASH ENCLOSURE WALL
GENERAL SHEET NOTES - DETAILS
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
REVISIONS
Δ DESCRIPTION DATE
3 " / 1 2 "5'-5 1/2"8'-0"6'-7 5/8"10'-5"
2" GAP, TYP.
2X6
2X3 5'-0"D3
L502
3'-0"4'-0"3'-0"4'-0"GRAVEL BASE
1. SUBMIT PRODUCT SAMPLES AND CUTSHEETS FOR ALL FINISHES INCLUDING TRIM PROFILES.
2. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS.
GENERAL SHEET NOTES -DETAILS
PAVERS
GRAVEL
LAWN
SEE SPEC FOR
BIKE LOCK
ASPHALT SHINGLE ROOF OVER ICE
AND WATER UNDERLAYMEMT
OVER 5/8" PLYWOOD WITH METAL
DRIP EDGE AT PERIMETER TO MATCH
MAIN BUILDING
4x4 LARCH POST
1X6 LARCH
1X3 LARCH
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
123 S. Cayuga St Suite 201
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
As indicated6/12/2019 3:39:39 PMU:\2018015 - 327 W. Seneca St - Visum\06.0 DRAWINGS\REVIT\BIKE SHED.rvtL502
BIKE SHED
2018015327 WEST SENECA ST.06/18/2019VISUM DEVELOPMENTCITY OF ITHACADESIGN DEVELOPMENT
REVISIONS
Δ DESCRIPTION DATE
1/2" = 1'-0"D2 EAST - ELEVATION
1/2" = 1'-0"D1 NORTH - ELEVATION
1/2" = 1'-0"C1 SOUTH - ELEVATION
1" = 1'-0"B1 FLOOR PLAN
1/2" = 1'-0"D3 EAST-SECTION
1/2" = 1'-0"C2 WEST - ELEVATION
4X4 POST @ 42"
BELOW GRADE
NORTH
0'1'6"
DW DW
DW DW
A203D1
A202
D1
A201
D1
A203 B1
70'-6 1/2"36'-6"D1
A302
D1
A302
UP
UNIT 103UNIT 102
UNIT 104
UNIT 101
MECH.
C104 BEDROOM 1
C106
BEDROOM 2
C107
CLO.
C108
MECH.
102
MECH.
B104
CLO.
B105
BEDROOM 1
B106
BEDROOM 2
B107
LIVING/ DINING
A101
BATH
A105
BATH
B103
BATH
C103
LIVING/ DINING
D101
CLO.
C105
BATH
D105
CLO.
B108
KITCHEN
D102
12'-5"2'-4"16'-9 1/4"6'-7"16'-9 1/4"2'-4"12'-5"
11'-8 1/2"4'-0"4'-3"
10'-7"
8'-2 3/4"2'-1 1/4"27'-6 3/4"4'-7 1/2"38'-4"
4'-10"5'-3"8'-8 1/4"3'-4"3'-4"4'-8"4'-7 1/2"5'-3 1/2"10'-0"5'-3"20'-6 1/2"15'-11 1/2"21'-7"3'-4"5'-3"6'-1"4'-5"5'-3"3'-4"21'-7"5'-3"10'-0"5'-3"4'-8"3'-4"3'-4"4'-8"3'-2"
C101A C101B
C107
C106
D101C
D101B
D101A
D100D104D105C106
C107C108C100102B100B101AB101BB108B107
B106
B104B105B106
B107
A100
A105100A101A
A101B
C104
70'-10"
E3
E2
E2
E1 E2E1
P3
P3 P3
P3
P3
P3
P1
P3
P1
P1
P1
P1
P1
P1
P1
P2
P1
E1
P1
P3
P3
P1
P1
P1
P1
P1
P1
P2
P1
P3
P1
E4
E2
P1A501
C2
A501
B2
A501
C2 SIM.
OPP.
HAND
A501
B1
A501
D1
4'-3"4'-4"11'-8"B103C103R @ 6 1/4"18
11" TREAD
TRASH TOTES
A204
CLO.
D104
REF.
KITCHEN
A102
SLEEPING
A103
CLO.
A104
P1
SLEEPING
D103
KITCHEN
B102
LIVING/ DINING
B101
LIVING/ DINING
C101
KITCHEN
C102
A204
D1
P1
2'-2"36'-6"C3
A301
C3
A301
P2P2
B1
A302
B1
A302
P1 P1 C105P3
REF.
REF.REF.
P1
P1
P1
E1 9'-7 3/4"9'-7 3/4"16'-0"STAIR ENTRY
100
STAIR
101
P1
P3
W/DW/D
W/D
W/D
E2
A204
A204
B1
A204
C3
A204
D3 12'-10"A1046'-9 1/2"6'-9 1/2"6'-9 1/2"3'-2 1/2"WH WH
RANGE
RANGERANGE
RANGE WH WH
D2
C2
3 3/4"
DS DS DS
DS DS DS
DS
8'-2 3/4"OPENING5'-0"9'-7 3/4"9'-7 3/4"16'-0"10'-7"15'-8 1/2"16'-0"11'-1 1/2"
2'-2"OPENING5'-0"3'-8"3'-8"3'-8"3'-8"2'-2"C1
A301
C1
A30120' - 4 5/16"Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1/4" = 1'-0"6/22/2020 10:09:16 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA101
FIRST FLOOR PLAN
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/4" = 1'-0"C1 1ST FLOOR PLAN
NORTHGENERAL SHEET NOTES - PLANS
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 Refer to wall schedules for wall and partition types, components, fire resistance, etc.
3 Exterior walls are 1-hour fire rated. See wall schedule.
4 All dimensions are to the face of studs, masonry or concrete, unless noted otherwise.
5 Unless noted otherwise, all gypsum wall board (GWB) shall be ⅝”, Type ‘X’.
6 Provide cement backing board in lieu of GWB at wall surfaces scheduled to receive ceramic, porcelain or stone
tiles.
7 Unless noted otherwise, all partitions shall extend to underside of deck or structure above.
8 Unless noted otherwise, space control joints in GWB walls and ceilings as required by ASTM C 840.
9 Floor elevation 0.00 is equivalent to elevation FFE on Site/Civil Plans.
10 Layout of one unit is the same as other similar units unless noted otherwise.
11 Third floor framing dimensions are identical to second floor U.N.O.
BATHROOMS
1 Provide moisture and mold resistant GWB in toilets, bathrooms, and other ‘wet’ locations.
2 “Type A” bathrooms are those that shall meet the accessibility requirements of Section 1003.11 of ICC A117.1
(Accessible and Usable Buildings and Facilities). Provide concealed blocking as required for installation of grab
bars in the future.
3 Provide concealed blocking to support towel bars, robe hooks, toilet paper holder and similar wall-mounted
accessories.
KITCHENS
1 Submit shop drawings showing casework and appliances, prior to ordering.
2 Adjust placement of appliances to permit complete and unobstructed opening of doors.
3 For appliances with reversible doors, coordinate swing direction with Architect prior to installation.
OPENINGS
1 Refer to door and window schedules for types, sizes, fire resistance and additional information.
2 Doors are centered on rooms, or 6" from wall on hinge side, unless noted otherwise.
3 Provide access doors as required to reach MEP items requiring maintenance or adjustment. Coordinate type and
size with MEP trades.
4 Provide double studs at all door jambs.
5 Provide (2) 2x6 headers (or steel stud equivalent) over windows and single door openings, unless noted
otherwise.
6 Provide concealed blocking behind door wall stops, and install stops as soon as practical, to prevent damage to
walls.
STAIRS AND RAILINGS
1 Unless noted otherwise, stair treads shall be ≥11”and stair risers ≤7”. Provide nosings as shown on drawings (or,
if not shown, as required by IBC Chapter 10).
2 Handrails, guardrails and grab bars shall resist loads described in IBC Section 1607.8.
REVISIONS
Δ DESCRIPTION DATE
1 REVISION 1 06/22/20
DW
DW
DW
DW
A203D1
A202
D1
A201
D1
A203 B1
C1
A301
C1
A301
D1
A302
D1
A302
UP
LIVING/ DINING
C201
BEDROOM 1
C205
BEDROOM 2
C206
CLO.
C207
BATH
C208
KITCHEN
D201
BATH
D202
CLO.
D204
BATH
B208
BEDROOM 1
B205
BEDROOM 2
B206
CLO.
B207
CLO.
B204
MECH/ LDRY
A203
BATH
A202CLO.
A204
ALL, U.N.O
VARIES
UNIT 203UNIT 202
UNIT 204UNIT 201
C206
C205C207
C204D202B206
B205 B207B204A202C208B208D200C200B200C203
D204A204B206A
B205
A205B
A205A
C206
C205
D205C
D205A
D205B
B201A B201CB201B C201A C201CC201BB206B
D205DA205CA203D20320120011'-5 1/2"15'-11 1/4"7'-10 3/4"12'-5"2'-4"14'-5"5'-5"5 1/2"5'-5"14'-5"2'-4"12'-5"16'-0"9'-7 3/4"9'-7 3/4"3'-3"5'-7"2'-9"7'-7 1/4"
8'-1"10'-2"3'-4"3'-4"21'-0"3'-4"3'-4"18'-3"3'-4"3'-4"9'-4"5'-3"10'-0"5'-3"4'-8"3'-4"3'-4"4'-8"5'-3"10'-0"5'-3"9'-10"13'-4 1/2"6'-8"11'-3"5'-11"13'-7 1/2"9'-10"
E2
E2
E2
E2
E2
P3
P3
P3
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P2
P1
E2
P2
P2
R @ 6 1/4"18
11" TREAD
MECH/ LDRY
D203
LIVING/ SLEEPING
D205
A200
P3
LIVING/ SLEEPING
A205
P1
LIVING/ DINING
B201
KITCHEN
B202
KITCHEN
C202
REF.
REF.REF.
REF.
A204
C1
C3
A301
C3
A301
B1
A302
B1
A302
70'-10"36'-6"16'-0"20'-6"P1
P3P3
P1 P1 9'-7 3/4"9'-7 3/4"16'-0"KITCHEN
A201
CLO.
B203
CLO.
C203
CLO.
C204
W/DW/D
B203
A203 D203
W/D W/D
A204B2
WH
WHWH
WH 3'-8"3'-8"RANGE
RANGERANGE
RANGE
5'-7"3'-3"P1
ELEC. PANEL
4"5'-3"A2043'-8"3'-8"7'-7 1/4"2'-9"
6'-3"
4'-1 1/4"4'-1 1/4"6'-3"
DS DS DS
DS DS DS
DS
15'-5"3'-2 1/2"3'-0"5'-6"3'-0"5'-6"
3'-0"5'-6"2' - 0 3/4"
A2
2' - 6"
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1/4" = 1'-0"6/22/2020 10:09:18 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA102
SECOND FLOOR PLAN
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/4" = 1'-0"C1 FLOOR PLAN - 2ND FLOOR
NORTHGENERAL SHEET NOTES - PLANS
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 Refer to wall schedules for wall and partition types, components, fire resistance, etc.
3 Exterior walls are 1-hour fire rated. See wall schedule.
4 All dimensions are to the face of studs, masonry or concrete, unless noted otherwise.
5 Unless noted otherwise, all gypsum wall board (GWB) shall be ⅝”, Type ‘X’.
6 Provide cement backing board in lieu of GWB at wall surfaces scheduled to receive ceramic, porcelain or stone
tiles.
7 Unless noted otherwise, all partitions shall extend to underside of deck or structure above.
8 Unless noted otherwise, space control joints in GWB walls and ceilings as required by ASTM C 840.
9 Floor elevation 0.00 is equivalent to elevation FFE on Site/Civil Plans.
10 Layout of one unit is the same as other similar units unless noted otherwise.
11 Third floor framing dimensions are identical to second floor U.N.O.
BATHROOMS
1 Provide moisture and mold resistant GWB in toilets, bathrooms, and other ‘wet’ locations.
2 “Type A” bathrooms are those that shall meet the accessibility requirements of Section 1003.11 of ICC A117.1
(Accessible and Usable Buildings and Facilities). Provide concealed blocking as required for installation of grab
bars in the future.
3 Provide concealed blocking to support towel bars, robe hooks, toilet paper holder and similar wall-mounted
accessories.
KITCHENS
1 Submit shop drawings showing casework and appliances, prior to ordering.
2 Adjust placement of appliances to permit complete and unobstructed opening of doors.
3 For appliances with reversible doors, coordinate swing direction with Architect prior to installation.
OPENINGS
1 Refer to door and window schedules for types, sizes, fire resistance and additional information.
2 Doors are centered on rooms, or 6" from wall on hinge side, unless noted otherwise.
3 Provide access doors as required to reach MEP items requiring maintenance or adjustment. Coordinate type and
size with MEP trades.
4 Provide double studs at all door jambs.
5 Provide (2) 2x6 headers (or steel stud equivalent) over windows and single door openings, unless noted
otherwise.
6 Provide concealed blocking behind door wall stops, and install stops as soon as practical, to prevent damage to
walls.
STAIRS AND RAILINGS
1 Unless noted otherwise, stair treads shall be ≥11”and stair risers ≤7”. Provide nosings as shown on drawings (or,
if not shown, as required by IBC Chapter 10).
2 Handrails, guardrails and grab bars shall resist loads described in IBC Section 1607.8.
REVISIONS
Δ DESCRIPTION DATE
DWDW
DWDW
A203D1
A202
D1
A201
D1
A203 B1
C1
A301
C1
A301
D1
A302
D1
A302
DN
UNIT 303UNIT 302
UNIT 304UNIT 301
LIVING/ DINING
C301
KITCHEN
C302
BEDROOM 2
C306
CLO.
C307
BEDROOM 1
C305
CLO.
C304
CLO.
D303
BATH
D302
CLO.
C303
CLO.
B304
KITCHEN
B302
BATH
B308
BATH
C308
CLO.
B303
CLO.
B307BEDROOM 2
B306
BEDROOM 1
B305
LIVING/ SLEEPING
A305
CLO.
A304
BATH
A302
BEDROOMS
BEDS
C306
C305C307
C304D302B306
B305 B307B304A302C308B308D300C300B300A300
B306A
B305
A305B
A305A
C306
C305
D305B
D305D
D305C
B301A B301CB301B C301A C301CC301BB306B
D305AA305CA302D302301300D303A304E2
E2
E2
E2
E2
P3
P3
P3
P3
P1
P1
P1
P1
P1
P1
P2 P1
P3
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P2
E2
KITCHEN
D301
P3
P3 P1P1
C3
A301
C3
A301
B1
A302
B1
A302
REF.REF.
REF.REF.
LIVING/ DINING
B301
P1P1
P1
P1
P1
P1
P3
P1
P1
KITCHEN
A301
MECH./ LDRY
A303
LIVING/ SLEEPING
D305
A303 B303C303D304
MECH./ LDRY
D304
WHWH
WHWH
W/D W/D
W/DW/D
P1
DS DS DS
DS DS DS
DS
ATTIC ACCESSATTIC ACCESS
D3
A302
D3
A302
B3
A302
B3
A302
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1/4" = 1'-0"6/22/2020 10:09:20 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA103
THIRD FLOOR PLAN
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/4" = 1'-0"C1 FLOOR PLAN - 3RD FLOOR
GENERAL SHEET NOTES - PLANS
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 Refer to wall schedules for wall and partition types, components, fire resistance, etc.
3 Exterior walls are 1-hour fire rated. See wall schedule.
4 All dimensions are to the face of studs, masonry or concrete, unless noted otherwise.
5 Unless noted otherwise, all gypsum wall board (GWB) shall be ⅝”, Type ‘X’.
6 Provide cement backing board in lieu of GWB at wall surfaces scheduled to receive ceramic, porcelain or stone
tiles.
7 Unless noted otherwise, all partitions shall extend to underside of deck or structure above.
8 Unless noted otherwise, space control joints in GWB walls and ceilings as required by ASTM C 840.
9 Floor elevation 0.00 is equivalent to elevation FFE on Site/Civil Plans.
10 Layout of one unit is the same as other similar units unless noted otherwise.
11 Third floor framing dimensions are identical to second floor U.N.O.
BATHROOMS
1 Provide moisture and mold resistant GWB in toilets, bathrooms, and other ‘wet’ locations.
2 “Type A” bathrooms are those that shall meet the accessibility requirements of Section 1003.11 of ICC A117.1
(Accessible and Usable Buildings and Facilities). Provide concealed blocking as required for installation of grab
bars in the future.
3 Provide concealed blocking to support towel bars, robe hooks, toilet paper holder and similar wall-mounted
accessories.
KITCHENS
1 Submit shop drawings showing casework and appliances, prior to ordering.
2 Adjust placement of appliances to permit complete and unobstructed opening of doors.
3 For appliances with reversible doors, coordinate swing direction with Architect prior to installation.
OPENINGS
1 Refer to door and window schedules for types, sizes, fire resistance and additional information.
2 Doors are centered on rooms, or 6" from wall on hinge side, unless noted otherwise.
3 Provide access doors as required to reach MEP items requiring maintenance or adjustment. Coordinate type and
size with MEP trades.
4 Provide double studs at all door jambs.
5 Provide (2) 2x6 headers (or steel stud equivalent) over windows and single door openings, unless noted
otherwise.
6 Provide concealed blocking behind door wall stops, and install stops as soon as practical, to prevent damage to
walls.
STAIRS AND RAILINGS
1 Unless noted otherwise, stair treads shall be ≥11”and stair risers ≤7”. Provide nosings as shown on drawings (or,
if not shown, as required by IBC Chapter 10).
2 Handrails, guardrails and grab bars shall resist loads described in IBC Section 1607.8.NORTHREVISIONS
Δ DESCRIPTION DATE
D1
A302
D1
A3026" / 12"6" / 12"6" / 12"6" / 12"B1
A302
B1
A302
RIDGE VENTTYP.2'-0"ICE + WATER SHIELD,
TYP. ENTIRE ROOF PERIMETER
LINE OF BUILDING BELOW
RIDGE VENT
GUTTER
GUTTER
D3
A302
D3
A302
B3
A302
B3
A302
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1/4" = 1'-0"6/22/2020 10:09:21 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA104
ROOF PLAN
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/4" = 1'-0"C1 ROOF PLAN
GENERAL SHEET NOTES - ROOFING
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 Review MEP drawings to determine exact quantity, type and location of roof penetrations.NORTHREVISIONS
Δ DESCRIPTION DATE
GFI @ 42 GFI @ 42 GFI @ 42220
GFI @ 42GFI @ 42220GFI @ 42GFI GFI @ 42GFI220
GFI @ 42GFI @ 42GFI @ 42 220
GFI @ 42GFI @ 42 220GFI @ 42GFIGFI @ 42GFI220
220220GFIGFIGFI GFI
BEDROOM 2
B107
BEDROOM 1
B106
LIVING/ DINING
A101
BATH
A105
BEDROOM 2
C107
BEDROOM 1
C106
KITCHEN
D102
LIVING/ DINING
D101
BATH
D105
BATH
C103BATH
B103
MECH.
STAIR ENTRY
LIVING/ DINING
B101
LIVING/ DINING
C101
KITCHEN
C102
KITCHEN
B102
KITCHEN
A102 SLEEPING
A103
SLEEPING
D103
STAIR
101
B
A
BB
B
B
B
B B
B
B
B
A
A A
AAAAAA
B
DD
D D
A A A AAA
A E
CC
CC
E
A
F
F
F
F
F F
FFFFF
ALL STAIR ENTRY, STAIR, AND CORRIDOR LIGHTING
TO REMAIN ON AT ALL TIMES AND CIRCUITED TO
EMERGENCY PANELBOARD IN MECH.RM.
CLO.
B108
CLO.
B105 MECH.
B104
CLO.
D104
CLO.
A104
CLO.
C105MECH.
C104
CLO.
C108
BIKE SHED
FFF
8' BASEBOARD TYP.
4' BASEBOARD TYP.
5'-10"5'-9 1/4"
ELEC. PANEL
6'-8" T.O. WALL OPENING
WALL HEATER
TIME CLOCK FOR EXTERIOR LIGHTS,
CIRCUIT TO EMERGENCY PANELBOARD.
WALL HEATER
WALL
HEATER
WALL
HEATER
ELEC. PANEL
ELEC. PANEL
ELEC. PANEL
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1/4" = 1'-0"6/22/2020 10:09:22 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA105
FIRST FLOOR
ELECTRIC PLAN
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/4" = 1'-0"C1 RCP - 1ST FLOOR
GENERAL SHEET NOTES - RCP/ Electrical
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 Submit shop drawings showing layout of fire alarm/ detector/ sprinkler system (Delegated Design) prior to start
of construction.
3 Coordinate location of sprinkler heads, light fixtures, HVAC grilles and similar items with MEP drawings.
4 Provide access doors as required to reach MEP items requiring maintenance or adjustment. Coordinate type and
size with MEP trades.
5 Unless noted otherwise, light fixtures shall be centered in the room or area they serve. If more than one, they
shall be installed symmetrically, as shown or implied on drawings.
6 Security system devices and wiring is Delegated Design by security subcontractor.
7 Data or wirelessaccess point devices and wiring is Delegated Design by elec. subcontractor or service provider.
8 Any notes on the C/D units apply to A/B side as well.
9 At first floor bathrooms and bedrooms, provide all necessary wiring and accessoris for future installation of
emergency strobes and signals required for ADA compliance.
LIGHTING FIXTURE SCHEDULE
Type Manufacturer Model FINISH
A Amax led-sm7dl/nkl White
AUX-LED Cooper Lighting AUX Series
B Lithonia fmlrl-11-148-35 White
C Style Selections vbl10lbnk White
D Panasonic fv-11vqcl6 White
E Cooper Lighting 23DW White
EM Cooper Industries, Inc. Model
F RAB Lighting VXBRLED13DG Black
REVISIONS
Δ DESCRIPTION DATE
220220GFI @ 42GFI @ 42GFI @ 42GFI 220
220 GFI
GFI GFI @ 42 GFI @ 42 GFI @ 42220
GFIGFIGFI @ 42
220
GFI @ 42GFI @ 42 GFI @ 42 220
GFI @ 42 GFI @ 42 GFI @ 42GFI @ 42GFI @ 42GFI @ 42GFI @ 42GFI @ 42220BEDROOM 2
B206 CLO.
B207
BEDROOM 1
B205
CLO.
B204
KITCHEN
B202
CLO.
C203
BATH
B208
BATH
C208
LIVING/ DINING
C201
KITCHEN
D201
KITCHEN
C202
BEDROOM 1
C205
BEDROOM 2
C206
CLO.
C207
CLO.
D204
BATH
D202
ALL, U.N.O
BATH
A202
MECH/ LDRY
A203
CLO.
A204
LIVING/ DINING
B201
LIVING/ SLEEPING
D205
LIVING/ SLEEPING
A205
CLO.
B203
CLO.
C204
BB
B
B
B
B B
B
B
B
BB
D
E
AAA
A
A
A
A
A
A
AA
AA AA
A
A
A
A
C C
DD
C C
D
A A
KITCHEN
A201
ALL STAIR ENTRY,STAIR,AND CORRIDOR LIGHTING TO REMAIN
ON AT ALL TIMES AND CIRCUITED TO EMERGENCY PANELBOARD
,EM ,EM ,EM
,EM
EXIT SIGN
MECH/ LDRY
D203
8' BASEBOARD TYP.
4' BASEBOARD TYP.
WALL HEATER
EXIT SIGN
ELEC. PANEL
ELEC. PANEL
E,EM
ELEC. PANEL
WALL HEATER WALL HEATER
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1/4" = 1'-0"6/22/2020 10:09:23 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA106
SECOND FLOOR
ELECTRIC PLAN
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/4" = 1'-0"C1 RCP - 2ND FLOOR
GENERAL SHEET NOTES - RCP/ Electrical
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 Submit shop drawings showing layout of fire alarm/ detector/ sprinkler system (Delegated Design) prior to start
of construction.
3 Coordinate location of sprinkler heads, light fixtures, HVAC grilles and similar items with MEP drawings.
4 Provide access doors as required to reach MEP items requiring maintenance or adjustment. Coordinate type and
size with MEP trades.
5 Unless noted otherwise, light fixtures shall be centered in the room or area they serve. If more than one, they
shall be installed symmetrically, as shown or implied on drawings.
6 Security system devices and wiring is Delegated Design by security subcontractor.
7 Data or wirelessaccess point devices and wiring is Delegated Design by elec. subcontractor or service provider.
8 Any notes on the C/D units apply to A/B side as well.
9 At first floor bathrooms and bedrooms, provide all necessary wiring and accessoris for future installation of
emergency strobes and signals required for ADA compliance.
LIGHTING FIXTURE SCHEDULE
Type Manufacturer Model FINISH
A Amax led-sm7dl/nkl White
AUX-LED Cooper Lighting AUX Series
B Lithonia fmlrl-11-148-35 White
C Style Selections vbl10lbnk White
D Panasonic fv-11vqcl6 White
E Cooper Lighting 23DW White
EM Cooper Industries, Inc. Model
F RAB Lighting VXBRLED13DG Black
REVISIONS
Δ DESCRIPTION DATE
GFI
GFI
220220GFI
GFI @ 42 GFI @ 42 GFI @ 42
GFIGFI @ 42GFI @ 42GFI @ 42220220
220
GFI @ 42GFI @ 42GFI @ 42GFI @ 42GFIGFI @ 42GFI @ 42GFI @ 42
GFI GFI @ 42GFI @ 42GFI @ 42220220
220GFIGFIPROVIDE DRAFTSTOPPING IN ATTIC
TO UNDERSIDE OF ROOF DECK.
PROVIDE A 48" X 48" OPENING,
COVERED WITH A REMOVABLE
PANEL, TO ALLOW ENTRY INTO
SOUTH HALF OF ATTIC
LIVING/ SLEEPING
A305
CLO.
A304
BATH
A302
CLO.
B303
BEDROOMS
BATH
D302 CLO.
D303
MECH./ LDRY
D304
CLO.
C303
LIVING/ DINING
C301
KITCHEN
B302
KITCHEN
C302 CLO.
C304
BEDROOM 1
C305
BEDROOM 2
C306
CLO.
C307
BATH
C308
BATH
B308CLO.
B307
BEDROOM 2
B306
BEDROOM 1
B305
CLO.
B304
LIVING/ SLEEPING
D305
KITCHEN
D301
KITCHEN
A301
MECH./ LDRY
A303
B
B
B
B
B
BB
B
B
B
B
B
DD
AA A
AA
A
A A
AAA
A A A
A
A A A
E
E
C C
C C
A
A A
D D
24" x 36"
ATTIC HATCH
LIVING/ DINING
B301
ALL STAIR ENTRY, STAIR, AND CORRIDOR LIGHTING TO REMAIN
ON AT ALL TIMES AND CIRCUITED TO EMERGENCY PANELBOARD
,EM ,EM ,EM
, EM
,EM
WALL
HEATER
8' BASEBOARD TYP.
4' BASEBOARD TYP.
ELEC. PANEL
EXIT SIGN
WALL HEATER
WALL
HEATER
WALL
HEATER
ELEC. PANEL ELEC. PANEL
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1/4" = 1'-0"6/22/2020 10:09:25 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA107
THIRD FLOOR
ELECTRIC PLAN
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/4" = 1'-0"C1 RCP - 3RD FLOOR
GENERAL SHEET NOTES - RCP/ Electrical
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 Submit shop drawings showing layout of fire alarm/ detector/ sprinkler system (Delegated Design) prior to start
of construction.
3 Coordinate location of sprinkler heads, light fixtures, HVAC grilles and similar items with MEP drawings.
4 Provide access doors as required to reach MEP items requiring maintenance or adjustment. Coordinate type and
size with MEP trades.
5 Unless noted otherwise, light fixtures shall be centered in the room or area they serve. If more than one, they
shall be installed symmetrically, as shown or implied on drawings.
6 Security system devices and wiring is Delegated Design by security subcontractor.
7 Data or wirelessaccess point devices and wiring is Delegated Design by elec. subcontractor or service provider.
8 Any notes on the C/D units apply to A/B side as well.
9 At first floor bathrooms and bedrooms, provide all necessary wiring and accessoris for future installation of
emergency strobes and signals required for ADA compliance.
LIGHTING FIXTURE SCHEDULE
Type Manufacturer Model FINISH
A Amax led-sm7dl/nkl White
AUX-LED Cooper Lighting AUX Series
B Lithonia fmlrl-11-148-35 White
C Style Selections vbl10lbnk White
D Panasonic fv-11vqcl6 White
E Cooper Lighting 23DW White
EM Cooper Industries, Inc. Model
F RAB Lighting VXBRLED13DG Black
REVISIONS
Δ DESCRIPTION DATE
1ST SUB FLOOR
396.62'
2ND FLOOR SUB FLOOR
406.04'
3RD FLOOR SUB FLOOR
415.45'
TOP OF 3RD STORY TOP PLATE
423.87'
MAIL BOXES,SEE SPEC.SEE DETAIL D3/L501
METAL CANOPY, SEE SPEC.
EXTERIOR LIGHT, SEE ELECTRICAL PLAN
(CENTER BETWEEN BATTENS)
BOARD AND BATTEN SIDING
1X8 TRIM
DOUBLE HUNG WINDOW
MODIFIED VENEER STUCCO
ROUND RAIN LEADER
ASPHALT SHINGLES
MODIFIED VENEER STUCCOWOOD RAILING 8'-5"9'-5"9'-5"D3
A302
D3
A302
B3
A302
B3
A302
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1/4" = 1'-0"6/22/2020 10:09:41 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA201
ELEVATION -WEST
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/4" = 1'-0"D1 ELEVATION - WEST
GENERAL SHEET NOTES - ELEVATIONS
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 Coordinate exterior elevation work with floor plans, window schedule and door schedule.
3 See schedules for head heights - coordinate adjacent window and door rough openings to ensure alignment of
head casings.
4 Coordinate location of safety glazing with Architect, prior to ordering doors or windows.
5 Coordinate quantity, location and type of Window Operation Control Devices (WOCD) with Architect, prior to
ordering windows.
6 Coordinate exterior elevation work with MEP drawings. Unless noted otherwise, center light fixtures, louvers and
similar items on door and window openings. Consult Architect prior to roughing in.
REVISIONS
Δ DESCRIPTION DATE
1ST SUB FLOOR
396.62'
2ND FLOOR SUB FLOOR
406.04'
3RD FLOOR SUB FLOOR
415.45'
TOP OF 3RD STORY TOP PLATE
423.87'
DOWNSPOUTFIRE SHUTTERFIRE SHUTTER A502
D3
C2
A502
B2
A502
A1
A502
D2
A502
D1
A502
B2
A502
9' - 5"9' - 5"8' - 5"D3
A302
D3
A302
B3
A302
B3
A302
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1/4" = 1'-0"6/22/2020 10:10:03 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA202
ELEVATION -EAST
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/4" = 1'-0"D1 ELEVATION - EAST
GENERAL SHEET NOTES - ELEVATIONS
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 Coordinate exterior elevation work with floor plans, window schedule and door schedule.
3 See schedules for head heights - coordinate adjacent window and door rough openings to ensure alignment of
head casings.
4 Coordinate location of safety glazing with Architect, prior to ordering doors or windows.
5 Coordinate quantity, location and type of Window Operation Control Devices (WOCD) with Architect, prior to
ordering windows.
6 Coordinate exterior elevation work with MEP drawings. Unless noted otherwise, center light fixtures, louvers and
similar items on door and window openings. Consult Architect prior to roughing in.
REVISIONS
Δ DESCRIPTION DATE
1ST SUB FLOOR
396.62'
2ND FLOOR SUB FLOOR
406.04'
3RD FLOOR SUB FLOOR
415.45'
TOP OF 3RD STORY TOP PLATE
423.87'
1ST SUB FLOOR
396.62'
2ND FLOOR SUB FLOOR
406.04'
3RD FLOOR SUB FLOOR
415.45'
TOP OF 3RD STORY TOP PLATE
423.87'8'-5"9'-5"9'-5"Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1/4" = 1'-0"6/22/2020 10:10:29 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA203
ELEVATIONS-
NORTH/ SOUTH
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/4" = 1'-0"B1 ELEVATION - NORTH
GENERAL SHEET NOTES - ELEVATIONS
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 Coordinate exterior elevation work with floor plans, window schedule and door schedule.
3 See schedules for head heights - coordinate adjacent window and door rough openings to ensure alignment of
head casings.
4 Coordinate location of safety glazing with Architect, prior to ordering doors or windows.
5 Coordinate quantity, location and type of Window Operation Control Devices (WOCD) with Architect, prior to
ordering windows.
6 Coordinate exterior elevation work with MEP drawings. Unless noted otherwise, center light fixtures, louvers and
similar items on door and window openings. Consult Architect prior to roughing in.
1/4" = 1'-0"D1 ELEVATION - SOUTH
REVISIONS
Δ DESCRIPTION DATE
REF.
RANGE
MIC
DW
12 34.5 2415 34.5 24
15 30 12
15 12 1215 12 12 15 12 12 15 12 12
12 30 12
15 24 12 15 24 12
12 30 12 12 30 12
30 34.5 24
15 12 12 15 12 12
12 30 12 12 30 12
15 24 12 15 24 12
15 12 12 15 12 12
21 30 12
DW
30 34.5 24
21 34.5 24
REF.
RANGE
MIC
12 30 12 12 30 12
15 24 1215 24 12
15 30 12
15 12 1215 12 12
18 30 12
15 12 1215 12 12
DW
30 34.5 24
15 34.5 2418 34.5 24
REF.
RANGE
MIC72"15"15"28"A204
W/D
P3
P1
P3
P3
P2 1'-3"2' - 6"2'-6"
4 '-0 "
D2
BATH
C103
PROVIDE BLOCKING FOR FUTURE
GRAB BARS, TYP. (GRAB BARS N.I.C)
A204
P3
P2
P1
E1
E11'-3"1'-3"2
' -
6
"
2'-
6
"4'-0 "BATH
A105
C25'-0 1/2"10'-7 1/2"72"MIN
8"
MIN
11"
MAX
6"MIN9"27" MIN34" MAXLAVATORY OR VANITY
SINK
COUNTER WHERE OCCURS
MIN
15"LAV AS SPECIFIED6"
12" MAXMIN
42"
59" MIN CLR
1.5" DIA GRAB BAR W/
1.5" GAP FROM WALL
33" - 36"1'-5" - 1'-7"16"-18"
WATER CLOSET SIDE WALL WATER CLOSET BACK WALLMIN18"39"-41"MIN.
24"
PROVIDE BLOCKING FOR
FUTURE GRAB BARS
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1/2" = 1'-0"6/22/2020 10:10:32 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA204
ENLARGED PLANS
AND INTERIOR ELEVS
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/2" = 1'-0"C1 KITCHEN- C202/ C302 (A202/ A203/ D202/ D203 SIM. B202/ B302 OPP. HAND)
1/2" = 1'-0"D1 KITCHEN- A102 (D102 OPP. HAND)
GENERAL SHEET NOTES - INTERIORS
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2
3
1/2" = 1'-0"B1 KITCHEN- C102 (B102 OPP. HAND)
1/2" = 1'-0"B2 INT. ELEVATION-BATHROOM C208/ C308 (B208/ C208 OPP. HAND)
1/2" = 1'-0"D3 FLOOR PLAN - ADA BATHROOM C103
1/2" = 1'-0"C3 FLOOR PLAN - ADA BATHROOM A105
1/2" = 1'-0"D2 INT.ELEVATION - ADA BATHROOM C103 (B103 OPP. HAND)
1/2" = 1'-0"C2 INT. ELEVATION- ADA BATHROOM A105 (D105 OPP. HAND)
1/2" = 1'-0"B3 TYPICAL PLUMBING FIXTURES AND ACCESSORIES
1/2" = 1'-0"A2 INT. ELEVATION BATHROOM D202 (A202 OPP. HAND)
REVISIONS
Δ DESCRIPTION DATE
1ST SUB FLOOR
396.62'
TOP OF 1ST STORY PLATE
405.00'
2ND FLOOR SUB FLOOR
406.04'
3RD FLOOR SUB FLOOR
415.45'
TOP OF 3RD STORY TOP PLATE
423.87'
TOP OF 2ND STORY PLATE
414.43'
LIVING/ SLEEPING
A305
LIVING/ SLEEPING
A205
LIVING/ DINING
A101
BATH
A105
BATH
A202
BATH
A302
ALL, U.N.O
BEDROOMS
STAIR ENTRY
BATH
D302
BATH
D202
BATH
D105
LIVING/ SLEEPING
D205
LIVING/ DINING
D1018'-5"1'-0 1/4"8'-4 3/4"1'-0 1/2"8'-4 1/2"A502
B2
A502
B1
A502
D2
A501
C1
A501
D2
A501
A1
A401
C1
A401
D1 LIVING/ SLEEPING
D305
DRAFTSTOPPING IN ATTIC 3'-6"8'-5"9'-5"9'-5"11-7/8" I-JOISTS W/ 3/4" SHEATHING
1ST SUB FLOOR
396.62'
TOP OF 1ST STORY PLATE
405.00'
2ND FLOOR SUB FLOOR
406.04'
3RD FLOOR SUB FLOOR
415.45'
TOP OF 3RD STORY TOP PLATE
423.87'
TOP OF 2ND STORY PLATE
414.43'
BEDROOM 2
C306
BEDROOM 2
C206
BEDROOM 2
C107
LIVING/ DINING
C101
LIVING/ DINING
C201
LIVING/ DINING
C301
BATH
C308
BATH
C208
BATH
B208
BATH
B308
MECH.
102
LIVING/ DINING
B101
LIVING/ DINING
B201
LIVING/ DINING
B301
BEDROOM 2
B306
BEDROOM 2
B206
BEDROOM 2
B107
DRAFTSTOPPING IN ATTIC
A501
B3
11-7/8" I-JOISTS W/ 3/4" SHEATHING
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1/4" = 1'-0"6/22/2020 10:10:35 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA301
SECTIONS
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/4" = 1'-0"C1 BUILDING SECTION 2
GENERAL SHEET NOTES - SECTIONS
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 Notes on one drawing, section or detail apply to all similar drawings, sections or details.
3 Floor elevation 0.00 is equivalent to elevation FFE on Site/Civil Plans.
1/4" = 1'-0"C3 BUILDING SECTION 1
REVISIONS
Δ DESCRIPTION DATE
1ST SUB FLOOR
396.62'
TOP OF 1ST STORY PLATE
405.00'
2ND FLOOR SUB FLOOR
406.04'
3RD FLOOR SUB FLOOR
415.45'
TOP OF 3RD STORY TOP PLATE
423.87'
TOP OF 2ND STORY PLATE
414.43'
BATH
B308
BATH
B208
LIVING/ DINING
B101
KITCHEN
B102
BATH
B103
STAIR ENTRY
100
ALL, U.N.O
VARIES
LIVING/ DINING
B201
LIVING/ DINING
B301
BEDROOMS
BEDS
A502
B3
TRUSS AND FLOOR FRAMING IS
DELEGATED DESIGN BY FRAMING
CONTRACTOR, TO BE REVIEWED BY
STRUCTURAL ENGINEER PRIOR TO
FABRICATION/CONSTRUCTION
A501
A1
PROVIDE 48" BY 48" OPENING
(TO BE CLOSED WITH PLYWOOD
PANEL) TO ALLOW ACCESS TO
OTHER SIDE OF ATTIC
11-7/8" I-JOISTS W/ 3/4" SHEATHING
1ST SUB FLOOR
396.62'
TOP OF 1ST STORY PLATE
405.00'
2ND FLOOR SUB FLOOR
406.04'
3RD FLOOR SUB FLOOR
415.45'
TOP OF 3RD STORY TOP PLATE
423.87'
TOP OF 2ND STORY PLATE
414.43'
BEDROOM 2
B306
BEDROOM 2
B206
BEDROOM 2
B107
BEDROOM 1
B106
BEDROOM 1
B205
BEDROOM 1
B305
LIVING/ SLEEPING
A305
LIVING/ SLEEPING
A205
LIVING/ DINING
A101
KITCHEN
A102
11-7/8" I-JOISTS W/ 3/4" SHEATHING
36' - 6"
1' - 4"1' - 4"1' - 4"
6 " / 1 2 "6" / 12"
1' - 4"
20' - 4 3/8"
1' - 4"1' - 4"6 " / 1 2 "6" / 12"
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1/4" = 1'-0"6/22/2020 10:10:36 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA302
SECTIONS
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/4" = 1'-0"D1 BUILDING SECTION 3
GENERAL SHEET NOTES - SECTIONS
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 Notes on one drawing, section or detail apply to all similar drawings, sections or details.
3 Floor elevation 0.00 is equivalent to elevation FFE on Site/Civil Plans.
1/4" = 1'-0"B1 BUILDING SECTION 4
ATTIC HATCH
REVISIONS
Δ DESCRIPTION DATE
1/4" = 1'-0"D3 TRUSS 01
1/4" = 1'-0"B3 TRUSS 02
122
122
122
122 1221028210262
122
42
42" AFF
TOP OF WALL
36" ABOVE STAIR NOSING
TOP OF RAILING
626242" AFF
TOP OF WALL
3'-0"SLOPED RAILING WALL
A401
C2
07 84 00.A1
2X FIRE STOPPING
RUBBER STAIR TREAD
& NOSING
SKIRT BOARD BEYOND
SEE PLANS FOR TREAD
AND RISER DIMENSIONS
07 84 00.A1
2X FIRE STOPPING
06 11 00.H1
2x10
07 84 00.A1
2X FIRE STOPPING
WALL TYPE PER PLAN
B-GUARD WALL
1 1/2"
1 1/2"
A-RAILING WALL
STEEL BRACKETS AS REQ'D
TO MEET IBC 1607.8
CONTINUOUS 2X BLK'G IN
WALL FOR BRACKET
ATTACHMENT
WOOD CAP, SEE SECTIONS FOR
SLOPING PORTIONS
06 46 00.E1
3/4" x 1 3/8" BASE CAP MOLDING
06 46 00.B2
3/4" x 3/4" COVE MOLDING
WALL TYPE P4
BLOCKING
WOOD CAP, SEE SECTIONS FOR
SLOPING PORTIONS
1/4" LUAN SHEATHING
06 46 00.B2
3/4" x 3/4" COVE MOLDING
06 46 00.E1
3/4" x 1 3/8" BASE CAP MOLDING
09 29 00.A2
3/8" GYPSUM WALLBOARD
6 1/2"
ONE HOUR FLOOR/CEILING ASSEMBLY:
INTERTEK WNR FCA 60-03.
STC 54 PER TJ-4035, ASSEMBLY B, TYP.
FLOORS 2 & 3
P1 P2
E1 E2
09 29 00.D11
5/8" TYPE "X" GYPSUM
WALLBOARD
06 11 00.G1
2x8
06 16 00.D17
7/16" ZIP SYSTEM
07 48 00.A5
1X3 FURRING STRIPS
07 21 00.A8
R-30 UNFACED BATT INSULATION -
MINERAL WOOL
07 46 23.D1
BOARD AND BATTEN SIDING
09 29 00.D11
5/8" TYPE "X" GYPSUM
WALLBOARD
06 11 00.G1
2x8
06 16 00.D17
7/16" ZIP SYSTEM
07 48 00.A5
1X3 FURRING STRIPS
07 21 00.A8
R-30 UNFACED BATT INSULATION -
MINERAL WOOL
09 29 00.M1
CEMENTITIOUS BACKER BOARD
09 24 00.B3
MODIFIED VENEER STUCCO
07 21 00.A3
R-15 UNFACED BATT INSULATION -
MINERAL WOOL
P3
09 29 00.D11
5/8" TYPE "X" GYPSUM
WALLBOARD
09 29 00.D11
5/8" TYPE "X" GYPSUM
WALLBOARD
UL U327 1-HR RATED
STC 50
09 29 00.D1
5/8" GYPSUM WALLBOARD
09 29 00.D1
5/8" GYPSUM WALLBOARD
09 29 00.D1
5/8" GYPSUM WALLBOARD
09 29 00.D1
5/8" GYPSUM WALLBOARD 2'-0" O.C.06 11 00.E1
2x6
09 29 00.L1
RC-1 RESILIENT CHANNEL –SINGLE
LEG
06 11 00.D1
2x4 06 11 00.E1
2x6
E3
09 29 00.D11
5/8" TYPE "X" GYPSUM
WALLBOARD
06 11 00.G1
2x8
06 16 00.D17
7/16" ZIP SYSTEM
07 48 00.A5
1X3 FURRING STRIPS
07 21 00.A8
R-30 UNFACED BATT INSULATION -
MINERAL WOOL
07 46 23.D1
BOARD AND BATTEN SIDING
E4
09 29 00.D11
5/8" TYPE "X" GYPSUM
WALLBOARD
06 11 00.G1
2x8
06 16 00.H2
1/2”MAGNESIUM OXIDE PANEL
07 48 00.A5
1X3 FURRING STRIPS
07 21 00.A8
R-30 UNFACED BATT INSULATION -
MINERAL WOOL
09 29 00.M1
CEMENTITIOUS BACKER BOARD
09 24 00.B3
MODIFIED VENEER STUCCO
1-HR RATED 1-HR RATED
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
As indicated6/22/2020 10:10:38 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA401
DETAILS
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1/2" = 1'-0"C1 STAIR GUARD- SLOPING WALL
1 1/2" = 1'-0"B1 STAIR- TREAD & RISER DETAIL
1 1/2" = 1'-0"B2 STAIR-LANDING
3" = 1'-0"C2 INTERIOR HANDRAIL AND CAPPED GUARD WALL
3" = 1'-0"D1 HALF WALL DETAIL
REFERENCE KEYNOTES
KEY NOTE
03 31 00.J5 4" CAST-IN-PLACE CONCRETE SLAB WITH 6x6 W2.9 x W2.9
05 05 23.E3 5/8" HOOKED ANCHOR BOLT
06 11 00.D1 2x4
06 11 00.E1 2x6
06 11 00.G1 2x8
06 11 00.H1 2x10
06 16 00.D8 5/8" PLYWOOD
06 16 00.D17 7/16" ZIP SYSTEM
06 16 00.H2 1/2” MAGNESIUM OXIDE PANEL
06 22 00.A2 1x2 WOOD TRIM
06 46 00.B2 3/4" x 3/4" COVE MOLDING
06 46 00.E1 3/4" x 1 3/8" BASE CAP MOLDING
07 21 00.A3 R-15 UNFACED BATT INSULATION - MINERAL WOOL
07 21 00.A6 R-23 UNFACED BATT INSULATION - MINERAL WOOL
07 21 00.A8 R-30 UNFACED BATT INSULATION - MINERAL WOOL
07 21 00.B6 3" XPS RIGID INSULATION
07 21 00.D1 DENSE-PACK SPRAY-APPLIED CELLULOSE INSULATION
07 24 00.A1 EIFS ON INSULATION BOARD
07 26 00.A5 CLASS III VAPOR RETARDER
07 27 00.A1 SILL SEALER
07 31 00.A1 ASPHALT SHINGLES
07 31 00.B2 ‘ICE AND WATER’ UNDERLAYMENT
07 31 00.C1 METAL DRIP EDGE
07 46 00.B1 WOOD COMPOSITE TRIM – 1x4
07 46 00.B8 WOOD COMPOSITE TRIM – 5/4x6
07 46 00.B9 WOOD COMPOSITE TRIM – 5/4x8
07 46 23.C2 FIBER CEMENT PANEL SIDING
07 46 23.C4 FIBER CEMENT SOFFIT PANEL - PERFORATED
07 46 23.D1 BOARD AND BATTEN SIDING
07 48 00.A5 1X3 FURRING STRIPS
07 48 00.B1 COR A VENT SV-5
07 62 00.A2 ALUMINUM FLASHING
07 62 00.H6 5" OGEE (K-STYLE) GUTTER
07 65 00.A3 SELF-ADHERED FLASHING
07 84 00.A1 2X FIRE STOPPING
07 92 00.A1 SEALANT – TYPE 1 (SILICONE, EXTERIOR)
07 92 00.A5 SEALANT – TYPE 5 (LATEX, INTERIOR)
07 92 00.A6 SEALANT – TYPE 6 (LATEX, ACOUSTICAL, FIRE RATED)
07 92 00.B2 BACKER ROD AND SEALANT
09 24 00.B3 MODIFIED VENEER STUCCO
09 29 00.A2 3/8" GYPSUM WALLBOARD
09 29 00.D1 5/8" GYPSUM WALLBOARD
09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD
09 29 00.D12 2 LAYERS 5/8" TYPE "X" GYPSUM BOARD
09 29 00.L1 RC-1 RESILIENT CHANNEL – SINGLE LEG
09 29 00.L3 RC-3 RESILIENT CHANNEL – ‘WHISPERCLIP’ WITH HAT CHANNEL
09 29 00.M1 CEMENTITIOUS BACKER BOARD
09 65 00.A1 RESILIENT FLOORING
31 05 19.A1 FILTER MAT
31 23 00.B1 GRAVEL
31 23 00.B2 COMPACTED GRAVEL SUB-BASE
33 46 00.A3 6" PERFORATED PVC PIPE
GENERAL SHEET NOTES - DETAILS
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 All 2x8 framing, 16" O.C.
3 See detail D1 for wall type P4
3/4" = 1'-0"
WALL TYPES
REVISIONS
Δ DESCRIPTION DATE
82
82
82 6282
82626262628
2828231
313131 318282
82
8282
31 3131626262
8282
4131
418282
07 92 00.A6
SEALANT –TYPE 6 (LATEX,
ACOUSTICAL, FIRE RATED)
07 21 00.A8
R-30 UNFACED BATT INSULATION -
MINERAL WOOL
09 29 00.D12
2 LAYERS 5/8" TYPE "X" GYPSUM
BOARD
09 65 00.A1
RESILIENT FLOORING
07 21 00.A3
R-15 UNFACED BATT INSULATION -
MINERAL WOOL
09 29 00.L3
RC-3 RESILIENT CHANNEL –
‘WHISPERCLIP’WITH HAT CHANNEL
06 16 00.D17
7/16" ZIP SYSTEM
4"ONE HOUR FLOOR/CEILING ASSEMBLY:
INTERTEK WNR FCA 60-03.
STC 54 PER TJ-4035, ASSEMBLY B, TYP.
FLOORS 2 & 3
1'-4"
12
6
07 31 00.A1
ASPHALT SHINGLES
07 31 00.B2
‘ICE AND WATER’UNDERLAYMENT
07 31 00.C1
METAL DRIP EDGE
06 16 00.D8
5/8" PLYWOOD
07 62 00.H6
5" OGEE (K-STYLE) GUTTER
07 46 23.C4
FIBER CEMENT SOFFIT PANEL -
PERFORATED
07 46 00.B9
WOOD COMPOSITE TRIM –5/4x8
07 21 00.D1
DENSE-PACK SPRAY-APPLIED
CELLULOSE INSULATION1' - 4"07 46 23.C2
FIBER CEMENT PANEL SIDING
07 31 00.C1
METAL DRIP EDGE
07 48 00.A5
1X3 FURRING STRIPS
1'-4"
07 31 00.B2
‘ICE AND WATER’UNDERLAYMENT
07 46 00.B8
WOOD COMPOSITE TRIM –5/4x6
06 16 00.D17
7/16" ZIP SYSTEM
1'-8"
07 46 23.C2
FIBER CEMENT PANEL SIDING
07 46 00.B1
WOOD COMPOSITE TRIM –1x4 1' - 8"09 24 00.B3
MODIFIED VENEER STUCCO
1"
E2
E1
P3
07 46 23.C2
FIBER CEMENT PANEL SIDING
ONE HOUR FLOOR/CEILING ASSEMBLY:
INTERTEK WNR FCA 60-03.
STC 54 PER TJ-4035, ASSEMBLY B, TYP.
FLOORS 2 & 3
DOUBLE TOP PLATE
GWB
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
1 1/2" = 1'-0"6/22/2020 10:10:38 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA501
DETAILS
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
1 1/2" = 1'-0"C1 SECOND AND THIRD FLOOR FRAMING
1 1/2" = 1'-0"A1 EAVE
1 1/2" = 1'-0"D2 ROOF-RAKE DETAIL
1 1/2" = 1'-0"B1 EXTERIOR CORNER AT FIBER CEMENT BOARD & BATTEN (PLAN)
1 1/2" = 1'-0"D1 EXTERIOR CORNER AT STUCCO
1 1/2" = 1'-0"C2 DEMISE WALL TRANSITION (PLAN)
1 1/2" = 1'-0"B2 P3 TO E1 TRANSITION
1 1/2" = 1'-0"B3 DOUBLE TOP PLATE FRAMING (TYPICAL AT ALL INTERIOR WALLS)
REVISIONS
Δ DESCRIPTION DATE
REFERENCE KEYNOTES
KEY NOTE
03 31 00.J5 4" CAST-IN-PLACE CONCRETE SLAB WITH 6x6 W2.9 x W2.9
05 05 23.E3 5/8" HOOKED ANCHOR BOLT
06 11 00.D1 2x4
06 11 00.E1 2x6
06 11 00.G1 2x8
06 11 00.H1 2x10
06 16 00.D8 5/8" PLYWOOD
06 16 00.D17 7/16" ZIP SYSTEM
06 16 00.H2 1/2” MAGNESIUM OXIDE PANEL
06 22 00.A2 1x2 WOOD TRIM
06 46 00.B2 3/4" x 3/4" COVE MOLDING
06 46 00.E1 3/4" x 1 3/8" BASE CAP MOLDING
07 21 00.A3 R-15 UNFACED BATT INSULATION - MINERAL WOOL
07 21 00.A6 R-23 UNFACED BATT INSULATION - MINERAL WOOL
07 21 00.A8 R-30 UNFACED BATT INSULATION - MINERAL WOOL
07 21 00.B6 3" XPS RIGID INSULATION
07 21 00.D1 DENSE-PACK SPRAY-APPLIED CELLULOSE INSULATION
07 24 00.A1 EIFS ON INSULATION BOARD
07 26 00.A5 CLASS III VAPOR RETARDER
07 27 00.A1 SILL SEALER
07 31 00.A1 ASPHALT SHINGLES
07 31 00.B2 ‘ICE AND WATER’ UNDERLAYMENT
07 31 00.C1 METAL DRIP EDGE
07 46 00.B1 WOOD COMPOSITE TRIM – 1x4
07 46 00.B8 WOOD COMPOSITE TRIM – 5/4x6
07 46 00.B9 WOOD COMPOSITE TRIM – 5/4x8
07 46 23.C2 FIBER CEMENT PANEL SIDING
07 46 23.C4 FIBER CEMENT SOFFIT PANEL - PERFORATED
07 46 23.D1 BOARD AND BATTEN SIDING
07 48 00.A5 1X3 FURRING STRIPS
07 48 00.B1 COR A VENT SV-5
07 62 00.A2 ALUMINUM FLASHING
07 62 00.H6 5" OGEE (K-STYLE) GUTTER
07 65 00.A3 SELF-ADHERED FLASHING
07 84 00.A1 2X FIRE STOPPING
07 92 00.A1 SEALANT – TYPE 1 (SILICONE, EXTERIOR)
07 92 00.A5 SEALANT – TYPE 5 (LATEX, INTERIOR)
07 92 00.A6 SEALANT – TYPE 6 (LATEX, ACOUSTICAL, FIRE RATED)
07 92 00.B2 BACKER ROD AND SEALANT
09 24 00.B3 MODIFIED VENEER STUCCO
09 29 00.A2 3/8" GYPSUM WALLBOARD
09 29 00.D1 5/8" GYPSUM WALLBOARD
09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD
09 29 00.D12 2 LAYERS 5/8" TYPE "X" GYPSUM BOARD
09 29 00.L1 RC-1 RESILIENT CHANNEL – SINGLE LEG
09 29 00.L3 RC-3 RESILIENT CHANNEL – ‘WHISPERCLIP’ WITH HAT CHANNEL
09 29 00.M1 CEMENTITIOUS BACKER BOARD
09 65 00.A1 RESILIENT FLOORING
31 05 19.A1 FILTER MAT
31 23 00.B1 GRAVEL
31 23 00.B2 COMPACTED GRAVEL SUB-BASE
33 46 00.A3 6" PERFORATED PVC PIPE
GENERAL SHEET NOTES - DETAILS
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 All 2x8 framing, 16" O.C.
3 See detail D1 for wall type P4
82
41 828241
8231 41828
282828282
82
82
82
82
82
823141
4107 46 23.C2
FIBER CEMENT PANEL SIDING
06 22 00.A2
1x2 WOOD TRIM
07 92 00.A1
SEALANT –TYPE 1 (SILICONE,
EXTERIOR)
09 29 00.D11
5/8" TYPE "X" GYPSUM
WALLBOARDBY WINDOW MFR
07 92 00.A5
SEALANT –TYPE 5 (LATEX,
INTERIOR)
07 92 00.B2
BACKER ROD AND SEALANT
09 29 00.D11
5/8" TYPE "X" GYPSUM
WALLBOARD
06 16 00.D17
7/16" ZIP SYSTEM07 65 00.A3
SELF-ADHERED FLASHING 07 46 23.C2
FIBER CEMENT PANEL SIDING5/16"
07 92 00.B2
BACKER ROD AND SEALANT
07 92 00.A5
SEALANT –TYPE 5 (LATEX,
INTERIOR)
07 48 00.B1
COR A VENT SV-5
06 16 00.D17
7/16" ZIP SYSTEM
07 65 00.A3
SELF-ADHERED FLASHING
07 65 00.A3
SELF-ADHERED FLASHING
SIDING VARIES
TRIM BY WINDOW MFR
07 46 23.C2
FIBER CEMENT PANEL SIDING
06 22 00.A2
1x2 WOOD TRIM
07 92 00.A1
SEALANT –TYPE 1 (SILICONE,
EXTERIOR)
07 92 00.B2
BACKER ROD AND SEALANT
09 29 00.D11
5/8" TYPE "X" GYPSUM
WALLBOARD
BY WINDOW MFR
07 92 00.A5
SEALANT –TYPE 5 (LATEX,
INTERIOR)
07 92 00.B2
BACKER ROD AND SEALANT
09 29 00.D11
5/8" TYPE "X" GYPSUM
WALLBOARD
06 16 00.D17
7/16" ZIP SYSTEM
07 65 00.A3
SELF-ADHERED FLASHING
SIDING TYPE VARIES
07 92 00.A5
SEALANT –TYPE 5 (LATEX,
INTERIOR)
09 29 00.D11
5/8" TYPE "X" GYPSUM
WALLBOARD
06 16 00.D17
7/16" ZIP SYSTEM
07 65 00.A3
SELF-ADHERED FLASHING
STEEL BRACKET PLATE ABOVE
SHUTTER
07 92 00.B2
BACKER ROD AND SEALANT
07 92 00.A5
SEALANT –TYPE 5 (LATEX,
INTERIOR)
07 48 00.B1
COR A VENT SV-5
06 16 00.D17
7/16" ZIP SYSTEM
07 65 00.A3
SELF-ADHERED FLASHING
2X BLOCKING, THRU-BOLT CLEVIS PER MANUF. INSTRUCTIONS
MANUF. ALUMINUM CANOPY,SEE SPEC.
THRU-BOLT CANOPY INTO RIM JOIST PER MANUF. INSTRUCTIONS
1X8 COMPOSITE TRIM
07 92 00.A5
SEALANT –TYPE 5 (LATEX,
INTERIOR)
07 65 00.A3
SELF-ADHERED FLASHING
07 62 00.A2
ALUMINUM FLASHING
FUSELINKS ON BOTH SIDES
OF OPENING
STEEL ANGLE
FLASHING
SIDING
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD
As indicated6/22/2020 10:10:40 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA502
WINDOW DETAILS
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
3" = 1'-0"B2 WINDOW SILL- FIBER CEMENT & BATTEN
3" = 1'-0"D1 WINDOW JAMB-FIBER CEMENT & BATTEN
3" = 1'-0"D2 WINDOW HEAD (TYP., EXCEPT AT FIRE SHUTTERS)
3" = 1'-0"B1 WINDOW SILL- STUCCO
3" = 1'-0"C1 WINDOW JAMB
3" = 1'-0"C2 WINDOW JAMB AT FIRE SHUTTER
3" = 1'-0"A1 WINDOW HEAD
REFERENCE KEYNOTES
KEY NOTE
03 31 00.J5 4" CAST-IN-PLACE CONCRETE SLAB WITH 6x6 W2.9 x W2.9
05 05 23.E3 5/8" HOOKED ANCHOR BOLT
06 11 00.D1 2x4
06 11 00.E1 2x6
06 11 00.G1 2x8
06 11 00.H1 2x10
06 16 00.D8 5/8" PLYWOOD
06 16 00.D17 7/16" ZIP SYSTEM
06 16 00.H2 1/2” MAGNESIUM OXIDE PANEL
06 22 00.A2 1x2 WOOD TRIM
06 46 00.B2 3/4" x 3/4" COVE MOLDING
06 46 00.E1 3/4" x 1 3/8" BASE CAP MOLDING
07 21 00.A3 R-15 UNFACED BATT INSULATION - MINERAL WOOL
07 21 00.A6 R-23 UNFACED BATT INSULATION - MINERAL WOOL
07 21 00.A8 R-30 UNFACED BATT INSULATION - MINERAL WOOL
07 21 00.B6 3" XPS RIGID INSULATION
07 21 00.D1 DENSE-PACK SPRAY-APPLIED CELLULOSE INSULATION
07 24 00.A1 EIFS ON INSULATION BOARD
07 26 00.A5 CLASS III VAPOR RETARDER
07 27 00.A1 SILL SEALER
07 31 00.A1 ASPHALT SHINGLES
07 31 00.B2 ‘ICE AND WATER’ UNDERLAYMENT
07 31 00.C1 METAL DRIP EDGE
07 46 00.B1 WOOD COMPOSITE TRIM – 1x4
07 46 00.B8 WOOD COMPOSITE TRIM – 5/4x6
07 46 00.B9 WOOD COMPOSITE TRIM – 5/4x8
07 46 23.C2 FIBER CEMENT PANEL SIDING
07 46 23.C4 FIBER CEMENT SOFFIT PANEL - PERFORATED
07 46 23.D1 BOARD AND BATTEN SIDING
07 48 00.A5 1X3 FURRING STRIPS
07 48 00.B1 COR A VENT SV-5
07 62 00.A2 ALUMINUM FLASHING
07 62 00.H6 5" OGEE (K-STYLE) GUTTER
07 65 00.A3 SELF-ADHERED FLASHING
07 84 00.A1 2X FIRE STOPPING
07 92 00.A1 SEALANT – TYPE 1 (SILICONE, EXTERIOR)
07 92 00.A5 SEALANT – TYPE 5 (LATEX, INTERIOR)
07 92 00.A6 SEALANT – TYPE 6 (LATEX, ACOUSTICAL, FIRE RATED)
07 92 00.B2 BACKER ROD AND SEALANT
09 24 00.B3 MODIFIED VENEER STUCCO
09 29 00.A2 3/8" GYPSUM WALLBOARD
09 29 00.D1 5/8" GYPSUM WALLBOARD
09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD
09 29 00.D12 2 LAYERS 5/8" TYPE "X" GYPSUM BOARD
09 29 00.L1 RC-1 RESILIENT CHANNEL – SINGLE LEG
09 29 00.L3 RC-3 RESILIENT CHANNEL – ‘WHISPERCLIP’ WITH HAT CHANNEL
09 29 00.M1 CEMENTITIOUS BACKER BOARD
09 65 00.A1 RESILIENT FLOORING
31 05 19.A1 FILTER MAT
31 23 00.B1 GRAVEL
31 23 00.B2 COMPACTED GRAVEL SUB-BASE
33 46 00.A3 6" PERFORATED PVC PIPE
GENERAL SHEET NOTES - DETAILS
1 Refer to Specifications, DIVISION 01, for additional information and requirements.
2 All 2x8 framing, 16" O.C.
3 See detail D1 for wall type P4
1 1/2" = 1'-0"B3 CANOPY DETAIL
3" = 1'-0"D3 WINDOW - FIRE SHUTTER
NOTE:
-PROVIDE ANDERSON 400 SERIES
WINDOWS ON N, E, AND W ELEVATIONS
-PROVIDE ANDERSEN 100 SERIES ON S
ELEVATION
REVISIONS
Δ DESCRIPTION DATE
Project #
Date
STREAM Collaborative
architecture + landscape
architecture dpc
108 W. State St. Fl 2
Ithaca, New York 14850
ph: 607.216.8802
www.streamcolab.com
A
1
2
3
4
BCD6/22/2020 10:10:42 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA601
SCHEDULES
2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET
VENTILATION - REQUIRED
MARK ROOM NAME AREA 4% VENT
1ST SUB FLOOR
A101 LIVING/ DINING 141 SF 6 SF
A102 KITCHEN 56 SF 2 SF
A103 SLEEPING 116 SF 5 SF
A101 13 SF
B101 LIVING/ DINING 247 SF 10 SF
B102 KITCHEN 100 SF 4 SF
B101 14 SF
B106 BEDROOM 1 113 SF 5 SF
B106 5 SF
B107 BEDROOM 2 113 SF 5 SF
B107 5 SF
C101 LIVING/ DINING 247 SF 10 SF
C102 KITCHEN 100 SF 4 SF
C101 14 SF
C106 BEDROOM 1 113 SF 5 SF
C106 5 SF
C107 BEDROOM 2 113 SF 5 SF
C107 5 SF
D101 LIVING/ DINING 161 SF 6 SF
D102 KITCHEN 37 SF 1 SF
D103 SLEEPING 117 SF 5 SF
D101 13 SF
2ND FLOOR SUB FLOOR
A205 LIVING/ SLEEPING 324 SF 13 SF
A205 13 SF
B201 LIVING/ DINING 294 SF 12 SF
B202 KITCHEN 67 SF 3 SF
B201 14 SF
B205 BEDROOM 1 113 SF 5 SF
B205 5 SF
B206 BEDROOM 2 113 SF 5 SF
B206 5 SF
C201 LIVING/ DINING 293 SF 12 SF
C202 KITCHEN 68 SF 3 SF
C201 14 SF
C205 BEDROOM 1 113 SF 5 SF
C205 5 SF
C206 BEDROOM 2 113 SF 5 SF
C206 5 SF
D201 KITCHEN 328 SF 13 SF
D205 13 SF
3RD FLOOR SUB FLOOR
A305 LIVING/ SLEEPING 324 SF 13 SF
A305 13 SF
B301 LIVING/ DINING 296 SF 12 SF
B302 KITCHEN 68 SF 3 SF
B301 15 SF
B305 BEDROOM 1 113 SF 5 SF
B305 5 SF
B306 BEDROOM 2 113 SF 5 SF
B306 5 SF
C301 LIVING/ DINING 295 SF 12 SF
C302 KITCHEN 68 SF 3 SF
C301 15 SF
C305 BEDROOM 1 113 SF 5 SF
C305 5 SF
C306 BEDROOM 2 113 SF 5 SF
C306 5 SF
D301 KITCHEN 328 SF 13 SF
D305 13 SF
VENTILATION - ACTUAL
MARK ROOM NAME VENT
1ST SUB FLOOR
A101 LIVING/ DINING 7 SF
B101 LIVING/ DINING 14 SF
B106 BEDROOM 1 7 SF
B107 BEDROOM 2 7 SF
C101 LIVING/ DINING 14 SF
C106 BEDROOM 1 7 SF
C107 BEDROOM 2 7 SF
D101 LIVING/ DINING 20 SF
2ND FLOOR SUB FLOOR
A205 LIVING/ SLEEPING 20 SF
B201 LIVING/ DINING 20 SF
B205 BEDROOM 1 7 SF
B206 BEDROOM 2 14 SF
C201 LIVING/ DINING 20 SF
C205 BEDROOM 1 7 SF
C206 BEDROOM 2 7 SF
D201 KITCHEN 27 SF
3RD FLOOR SUB FLOOR
A305 LIVING/ SLEEPING 20 SF
B301 LIVING/ DINING 20 SF
B305 BEDROOM 1 7 SF
B306 BEDROOM 2 14 SF
C301 LIVING/ DINING 20 SF
C305 BEDROOM 1 7 SF
C306 BEDROOM 2 7 SF
D301 KITCHEN 27 SF
WINDOW SCHEDULE
MARK OPERATION
UNIT
WIDTH
UNIT
HEIGHT
SILL
HEIGHT
HEAD
HEIGHT GLAZING SAFETY WOCD EGRESS COMMENTS HEADER
1ST SUB FLOOR
A101A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes SAFETY GLASS (2) 2x (?) TYPICAL
A101B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes
B101A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes
B101B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes
B106 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes
B107 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes
C101A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes
C101B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes
C106 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes
C107 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes
D101A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes
D101B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes
D101C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes
2ND FLOOR SUB FLOOR
200 FIXED 2' - 0" 3' - 0" 0" 3' - 0" TYPE "B"
SMARTSUN
Yes SAFETY GLASS (2) 2x (?) TYPICAL
201 FIXED 2' - 0" 3' - 0" 4' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes SAFETY GLASS
A203 FIXED 2' - 0" 3' - 0" 4' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes SAFETY GLASS,
PATTERNED
A205A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
A205B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
A205C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
B201A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
B201B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
B201C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
B205 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
B206A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
B206B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
C201A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
C201B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
C201C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
C205 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
C206 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
D203 FIXED 2' - 0" 3' - 0" 4' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes SAFETY GLASS,
PATTERNED
D205A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
D205B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
D205C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
D205D SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
3RD FLOOR SUB FLOOR
300 FIXED 2' - 0" 3' - 0" 0" 3' - 0" TYPE "B"
SMARTSUN
Yes SAFETY GLASS (2) 2x (?) TYPICAL
301 FIXED 2' - 0" 3' - 0" 4' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes SAFETY GLASS
A302 FIXED 2' - 0" 3' - 0" 4' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes SAFETY GLASS,
PATTERNED
A305A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
A305B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
A305C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
B301A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
B301B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
B301C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
B305 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
B306A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
B306B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
C301A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
C301B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
C301C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes
C305 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
C306 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
D302 FIXED 2' - 0" 3' - 0" 4' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes SAFETY GLASS,
PATTERNED
D305A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
D305B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
D305C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
D305D SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B"
SMARTSUN
Yes Yes
DOOR SCHEDULE
MARK
ROOM
NAME WIDTH HEIGHT DESCRIPTION
FRAME
MATERIAL
DOOR
MATERIAL
FIRE
RATING
HARDWARE
SET
1ST SUB FLOOR
100 STAIR ENTRY 3' - 0" 7' - 0" 1-LITE ALUM FRP 1
102 MECH. 3' - 0" 7' - 0" FLUSH ALUM FRP 8
A100 KITCHEN 3' - 0" 7' - 0" 1-LITE HM FRP 2
A104 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
A105 BATH 3' - 0" 6' - 8" 2-PANEL WD MASONITE 5
B100 LIVING/ DINING 3' - 0" 7' - 0" 2-PANEL ALUM FRP 45 MIN 2
B103 BATH 3' - 0" 6' - 8" 2-PANEL WD MASONITE 5
B104 MECH. 2' - 2" 6' - 8" 2-PANEL WD MASONITE 7
B105 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
B106 BEDROOM 1 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4
B107 BEDROOM 2 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4
B108 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
C100 LIVING/ DINING 3' - 0" 7' - 0" 2-PANEL ALUM FRP 45 MIN 2
C103 BATH 3' - 0" 6' - 8" 2-PANEL WD MASONITE 5
C104 MECH. 2' - 2" 6' - 8" 2-PANEL WD MASONITE 7
C105 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
C106 BEDROOM 1 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4
C107 BEDROOM 2 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4
C108 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
D100 LIVING/ DINING 3' - 0" 7' - 0" 1-LITE ALUM FRP 1
D104 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
D105 BATH 3' - 0" 6' - 8" 2-PANEL WD MASONITE 5
2ND FLOOR SUB FLOOR
A200 LIVING/ SLEEPING 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3
A202 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5
A203 MECH/ LDRY 5' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
A204 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
B200 LIVING/ DINING 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3
B203 CLO. 6' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
B204 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
B205 BEDROOM 1 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4
B206 BEDROOM 2 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4
B207 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
B208 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5
C200 LIVING/ DINING 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3
C203 CLO. 6' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
C204 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
C205 BEDROOM 1 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4
C206 BEDROOM 2 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4
C207 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
C208 LIVING/ DINING 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5
D200 KITCHEN 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3
D202 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5
D203 KITCHEN 5' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
D204 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
3RD FLOOR SUB FLOOR
A300 LIVING/ SLEEPING 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3
A302 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5
A303 LIVING/ SLEEPING 5' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
A304 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
B300 LIVING/ DINING 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3
B303 LIVING/ DINING 6' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
B304 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
B305 LIVING/ DINING 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4
B306 BEDROOM 2 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4
B307 BEDROOM 2 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
B308 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5
C300 LIVING/ DINING 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3
C303 CLO. 6' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
C304 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
C305 BEDROOM 1 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4
C306 BEDROOM 2 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4
C307 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
C308 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5
D300 KITCHEN 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3
D302 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5
D303 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
D304 MECH./ LDRY 5' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7
ROOM FINISH SCHEDULE
ROOM
NUMBER
ROOM
NAME
FLOOR
FINISH BASE FINISH
WALL
FINISH
CEIING
FINISH COMMENTS
100 STAIR ENTRY RESILIENT RESILIENT PAINT PAINT 1, 4
101 STAIR RESILIENT RESILIENT PAINT PAINT 1, 4
102 MECH. FIN. CONCRETE RESILIENT PAINT PAINT 4
BEDS BEDROOMS CARPET TILE RESILIENT PAINT PAINT 3, 4
VARIES ALL, U.N.O RESILIENT RESILIENT PAINT PAINT 2, 4
1.PROVIDE RESILIENT THERMOSET FLOOR/BASE PRODUCTS, PER SPEC ______
2.RESILIENT FLOORING AND BASE TO BE SELECTED BY OWNER.
3.CARPET TILE TO BE SELECTED BY OWNER.
4.PAINT COLOR TO BE SELECTED BY OWNER. REFER TO SPEC. SECTION 09 9100 FOR SHEEN AND NUMBER OF COATS.
REVISIONS
Δ DESCRIPTION DATE