Loading...
HomeMy WebLinkAbout2018015 - 327 W Seneca Street - 06.22.2020 - Revision 1Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com DESIGN TEAM STREAM Collaborative Architecture & Landscape Architecture DPC Noah Demarest RA, RLA, LEED AP ph: 607.216.8802 noah@streamcolab.com ELWYN+PALMER Consulting Engineers MARATHON Engineering A 1 2 3 4 BCD6/22/2020 10:09:14 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA000 COVER SHEET 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 327 W. SENECA STREET VISUM DEVELOPMENT CITY OF ITHACA, NY DRAWING LIST SHEET DRAWING NAME 00 - GENERAL A000 COVER SHEET 01 - CIVIL C1.0 SANITARY LATERAL PLAN 02 - LANDSCAPE L001 SITE LAYOUT PLAN AND PLANTING PLAN L002 UTILITY PLAN AND WORK ZONE PLAN L003 GRADING PLAN L501 SITE DETAILS L502 BIKE SHED 03 - ARCHITECTURE A101 FIRST FLOOR PLAN A102 SECOND FLOOR PLAN A103 THIRD FLOOR PLAN A104 ROOF PLAN A105 FIRST FLOOR ELECTRIC PLAN A106 SECOND FLOOR ELECTRIC PLAN A107 THIRD FLOOR ELECTRIC PLAN A201 ELEVATION - WEST A202 ELEVATION - EAST A203 ELEVATIONS- NORTH/ SOUTH A204 ENLARGED PLANS AND INTERIOR ELEVS A301 SECTIONS A302 SECTIONS A401 DETAILS A501 DETAILS A502 WINDOW DETAILS A601 SCHEDULES 04 - STRUCTURAL S001 GENERAL NOTES S100 EXISTING BUILDING FOUNDATION DEMO PLAN S101 FOUNDATION PLAN S300 FOUNDATION DETAILS 05 - ELECTRICAL E100 ELECTRIC RISER DIAGRAM VICINITY MAP REVISIONS Δ DESCRIPTION DATE AVERAGE LOT DEPTH 88.71'EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDING PUBLIC SIDEWALK WEST SENECA STREET 87° 34' 30" 52.00' N E 2° 09' 56"90.29'SE87° 44' 38" 26.94' S W2° 13' 55"87.42'NW87° 59' 37" 25.01' S W PROPOSED 3-STORY APARTMENT 327 W. SENECA ST. LAWN NEW LAWN EXISTING CITY TREES TO REMAIN HBA 4 TOS 1 TOS 1 HBA 4 TOS 1 HMA 3 HBA 2 TOS 1 HBA 2 TOS 1 HMA 3 CFD 2 LAWN LAWNLAWN LAWNBIKE SHEDBZA APPROVED SETBACK10'TRASH CAN ENCLOSURENEW WALKMAIL AVERAGE LOT DEPTH 88.71'NEW WALKBIKE SHEDWEST SENECA STREET EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDING EXISTING EXIT DOOR EXISTING SIDEWALK NEW SIDEWALK 7.05'PROPOSED 3-STORY APARTMENT 327 W. SENECA ST. NEW CURB CURB CUT TO BE REMOVED 6.55' ±8.84' ±CANOPY CANOPY CANOPIES BIKE RACK PUBLIC SIDEWALK EXISTING EGRESS WALKWAY EXISTING PARKING LOT REQUIRED SETBACK13.3'1' BZA APPROVED SETBACK3' BZA APPROVED SETBACK6' BZA APPROVED SETBACK 10.08' 10' REQUIRED SETBACK 5' REQUIRED SETBACK 36.83'10.59'10' REQUIRED SETBACK23'-10"8'-0"21'-6"5'-0"12'-4"27'-6"15'-0"28'-6"4'-0" 9'-1"5'-0"22'-9"11'-10"4'-1"6'-8" COVERED WOOD BIKE SHED (ACCESSORY STRUCTURE) ±8'-0" HIGH 4'-0"4'-0" 4'-0" L501 D3 4'-0" ASPHALT PATCH EXISTING BUILDING TO BE DEMOLISHED BY OWNER. SEE DWG S100. EXG. CMU PRIVACY WALL TO BE DEMOLISHED BY OWNER. Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1" = 10'-0"6/12/2019 3:31:12 PMC:\Users\Steven\Documents\2018015 - 327 W.Seneca Street - Site_stevenPUFGL.rvtL001 SITE PLAN AND PLANTING PLAN 2018015327 WEST SENECA ST.06/18/2019VISUM DEVELOPMENTCITY OF ITHACA, NYDESIGN DEVELOPMENT 1" = 10'-0"D1 PLANTING PLAN 1" = 10'-0"C1 SITE LAYOUT PLAN N PLANTING SCHEDULE KEY QTY. BOTANICAL NAME COMMON NAME INSTALLED SIZE MATURE SIZE COMMENTS SHRUB - PERENNIAL HMA 6 Hakonechloa macra 'Aureola' Golden Japanese Forest Grass #1 CONTAINER 1.5' TALL & WIDE SHADE TOLERANT HBA 12 Hosta x 'Blue Angel' Blue Angel Plantain Lily #1 CONTAINER 4' WIDE SHADE TOLERANT TREE - ORNAMENTAL CFD 2 Cornus florida Flowering Dogwood 2" CALIPER 25' TALL TREE -EVERGREEN TOS 5 Thuja occidentalis 'Skybound' Skybound Arborvitae 6 FEET TALL 15-20' TALL COLUMNAR GENERAL SHEET NOTES - PLANTING 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 Consult landscape architect on shape of bed edge and placement of all plants prior to installation. 3 Only nursery-grown plant materials shall be acceptable. All trees, shrubs and ground covers shall comply with applicable requirements of ANSI z60.1, American standard for nursery stock. 4 All planting beds to be excavated to a minimum depth of two feet and replaced with amended topsoil consisting of 1 part screened topsoil, 1 part compost and 1 part sand. 5 Tree pits in lawn to be excavated to depth of root ball plus six inches and shall be three times the width of the root ball. 6 Deciduous trees shall have a caliper of at least 2 1/2 inches at breast height (DBH) at the time of planting. 7 All trees in lawn areas to receive five-foot diameter mulch rings. 8 Install 3 inches of natural shredded bark mulch in all planting beds. 9 No plants or trees shall be located beneath building overhangs. 10 Sun/shade lawn mix - deep till any compaction due to construction and install 4" of amended topsoil. 11 Warranty all plant materials for a period of 1-year beyond the date of substantial completion. GENERAL SHEET NOTES - SITE LAYOUT 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 General contractor shall notify all utility owners having underground utilities on site prior to excavation. Contractor shall contact utility locating company and locate all utilities prior to any excavation. 3 See civil drawings for layout of underground utilities. 4 See electrical drawings for layout of underground electrical and lighting. 5 Install expansion joints every 30' in concrete and in areas where concrete abuts curbs and other fixed objects. 6 Verify dimensions and accept conditions before proceeding with work. Report discrepancies to landscape architect before proceeding. 7 Do not scale drawings. 8 Walks, drives, curbs, parking, and building locations to be laid out in the field by a licensed surveyor. 9 Dimensions to curbs are to exposed faces unless otherwise noted. N REVISIONS Δ DESCRIPTION DATE WEST SENECA STREET EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDING PUBLIC SIDEWALK PROPOSED 3-STORY APARTMENT 327 W. SENECA ST. O.H.O.H. O.H. SAN *SEE CIVIL DWGS FOR SAN CONNECTION W SAN W WW E MECHANICAL ROOM WEST SENECA STREET EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDING EXISTING EXIT DOOR EXISTING SIDEWALK PUBLIC SIDEWALK PROPOSED 3-STORY APARTMENT 327 W. SENECA ST. ACCESS TO BE MAINTAINED THROUGH NEGOTIATION W/ ADJACENT PROPERTY OWNERS DURING CONSTRUCTION TEMPORARY CONSTRUCTION FENCE AT PROPERTY LINE MAINTAIN ACCESS TO ADJACENT PROPERTIES TEMPORARY CONSTRUCTION FENCE AT PROPERTY LINE STAGING AREA. STREET PERMIT TO BE ACQUIRED PUBLIC SIDE WALK TO BE CLOSED DURING CONSTRUCTION. PROVIDE SIDEWALK DETOUR SIGNAGE AS REQUIRED BY CITY EXISTING EGRESS WALKWAY EXISTING PARKING LOT TREE PROTECTION. 6'-0" TALL, 5'-0" x 12'-0" CHAIN LINK FENCE. REPLACE TREES IF THEY ARE DAMAGED OR DIE WITHIN ONE YEAR OF CONSTRUCTION Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1" = 10'-0"6/12/2019 3:31:16 PMC:\Users\Steven\Documents\2018015 - 327 W.Seneca Street - Site_stevenPUFGL.rvtL002 UTILITY PLAN AND WORK ZONE PLAN 2018015327 WEST SENECA ST.06/18/2019VISUM DEVELOPMENTCITY OF ITHACA, NYDESIGN DEVELOPMENT 1" = 10'-0"B1 UTILITY PLAN 1" = 10'-0"D1 WORK ZONE TRAFFIC CONTROL PLAN NN REVISIONS Δ DESCRIPTION DATE 1 Revision 1 Date 1 TRASH CAN ENCLOSUREAVERAGE LOT DEPTH 88.71'BIKE SHEDWEST SENECA STREET EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDING EXISTING EXIT DOOR EXISTING SIDEWALK PROPOSED 3-STORY APARTMENT 327 W. SENECA ST. NEW CURB CURB CUT TO BE REMOVED PUBLIC SIDEWALK EXISTING EGRESS WALKWAY EXISTING PARKING LOT 6'-8 1/8" ASPHALT PATCH 396.39 396.62 396.58 396.63 396.59 396.64396.5 396.65396.51 396.59 396.65396.65 396.5 397 396.58 396.61 396.65 396.65 396.61 1% 396.61396.61 396.64 396.64 396.47 396.65 396.65 396.5 396.38 396.39 396.25 396.18 FFE 396.62' Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1" = 10'-0"6/12/2019 3:31:18 PMC:\Users\Steven\Documents\2018015 - 327 W.Seneca Street - Site_stevenPUFGL.rvtL003 GRADING PLAN 2018015327 WEST SENECA ST.06/18/2019VISUM DEVELOPMENTCITY OF ITHACA, NYDESIGN DEVELOPMENT 1" = 10'-0"B1 GRADING PLAN GENERAL SHEET NOTES - SITE LAYOUT 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 General contractor shall notify all utility owners having underground utilities on site prior to excavation. Contractor shall contact utility locating company and locate all utilities prior to any excavation. 3 See civil drawings for layout of underground utilities. 4 See electrical drawings for layout of underground electrical and lighting. 5 Install expansion joints every 30' in concrete and in areas where concrete abuts curbs and other fixed objects. 6 Verify dimensions and accept conditions before proceeding with work. Report discrepancies to landscape architect before proceeding. 7 Do not scale drawings. 8 Walks, drives, curbs, parking, and building locations to be laid out in the field by a licensed surveyor. 9 Dimensions to curbs are to exposed faces unless otherwise noted. REVISIONS Δ DESCRIPTION DATE CONCRETE SLAB 6 X 6 X W1.4 X W1.4 MESH, FLAT SHEETS ONLY SET ON CHAIRS COMPACTED SUBBASE COMPACTED SUBGRADE NOTES 1. SEE PLANS FOR TOOL JOINTS (TJ), EXPANSION JOINTS (EJ), LAYOUT WIDTHS, RADII AND FINISHES 2. 2" MINIMUM CONCRETE COVERAGE ON MESH AND TIES 8"5"WIDTH AS SHOWN ON PLAN CROSS SLOPE AS SHOWN ON GRADING PLAN CONCRETE SLAB (2) 6 X 6 X W2.9 X W2.9, 2" MIN. CLR. TOP AND BOTTOM COMPACTED SUBBASE COMPACTED SUBGRADE NOTES 1. SEE PLANS FOR TOOL JOINTS (TJ), EXPANSION JOINTS (EJ), LAYOUT WIDTHS, RADII AND FINISHES 2. 2" MINIMUM CONCRETE COVERAGE ON MESH AND TIES 1'-0"8"WIDTH AS SHOWN ON PLAN CROSS SLOPE AS SHOWN ON GRADING PLAN NOTES 1. TOOL JOINTS EVERY 5'-0" MAX TYPICAL OR EQUALLY SPACED BETWEEN SITE FEATURES. 2. EXPANSION JOINTS ARE REQUIRED EVERY 50' AND AT FIXED FEATURES LIKE BUILDINGS, LIGHT POSTS, PADS, ETC. 3. OVERLAP MESH SHEETS 1'-0" MIN 1/2" EXPANSION JOINT (EJ) AND JOINT SEALANT 1/2" S.S. DOWEL x24" W/ PLASTIC SLEEVE AT 18" O.C. CONCRETE WALK COMPACTED SUBBASE COMPACTED SUBGRADE 1' DEEP TOOL JOINT (TJ) W/ 1/4" RADIUS MEDIUM BROOM FINISH WIDTH AS SHOWN ON PLANWIDTH AS SHOWN ON PLANNOTES 1. BROOM PERPENDICULAR TO LINE OF TRAFFIC TOOLED EDGE AROUND EACH SCORE JOINT AND EACH EXPANSION JOINT 2" SUBBASE COURSE MATERIAL, TYPE 4 SOIL STABILIZATION FABRIC SAW-CUT AND 2" DEEP MILL 12" WIDE BOTH SIDES PRIOR TO INSTALLING ASPHALT TOP COURSE TACK COAT EXISTING PAVEMENT PAVEMENT RECONSTRUCTION OR FULL DEPTH MILLING 1'-0" SEAM SEALER MUST BE APPLIED TO ALL JOINTS GRAVEL BACKFILL PER TRENCH DETAIL NOTES: 1. PRIOR TO DEMOLITION ADJACENT ASPHALT MUST BE SAW-CUT FULL DEPTH OF PAVEMENT 2. TACK COAT MUST BE APPLIED TO ALL HORIZONTAL AND VERTICAL SEEMS PRIOR TO PLACEMENT OF TOP-COURSE NYSDOT TYPE 7 TOP COURSE ITEM 403.198902 NYSDOT TYPE 3 BINDER ITEM 403.138902 2"3"1'-0"BIKE RACK PER MANUFACTURER INSTALLATION INSTRUCTIONS CORE INTO PAVERS AND CONCRETE, FILL WITH POR-ROK OR EPOXY GROUT, SET RACK LEVEL TO GRADE CONCRETE PAVEMENT PITCH 1:12 MAX PITCH 1:12 PLAN CONCRETE OR PAVERS WHERE SHOWN PLANTING WHERE SHOWN DROP CURB DETECTABLE WARNING PLATES ISOMETRIC VIEW PITCH 1:12 1 12 1 12 6' - 0" TYP6' TYP 6' TYP 8' TYP 6' TYP NOTES 1. SEE LAYOUT PLAN FOR LOCATION OF CURB PLANKS 2. GRADE CHANGES TO BE SMOOTH AND EVENLY PITCHED 3. INSTALL DETECTABLE WARNING PLATES AS PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2" SINGLE GROUND HARDWOOD BARK MULCH PLANTING MIX -TOPSOIL (1 PART), COMPOST (1 PART), SAND (1 PART) 5'-0" SPADED EDGE -TYPICAL COMPACTED PLANTING MIX BENEATH ROOT BALL TO PREVENT SETTLING 3X ROOT BALLROOT BALL + 6"2"-3" SINGLE GROUND HARDWOOD BARK MULCH PLANTING MIX -TOPSOIL (1 PART), COMPOST (1 PART), SAND (1 PART) 4" TOPSOIL FOR LAWNS SPADED EDGE -TYPICAL 1'-6" MINCOMPACTED PLANTING MIX BENEATH ROOT BALL TO PREVENT SETTLING METAL LANDSCAPE EDGING, STAKED EXTERIOR WALL & FINISH PER WALL TYPE 4"31 23 00.B1 6"31 05 19.A1 LAYER OF GEOTEXTILE PER MANUF RECOMMENDATIONS PAVER AS SELECTED BY ARCHITECT 1" SAND SETTING COMPACTED SUBBASE PERFORATED DRAINAGE PIPE OUT TO DAYLIGHT 6" CONCRETE BASE ADJACENT PAVING GRANITE CURB 1/2" BATTERED FACE, 6" DOWN FROM SAWN TOP ADJACENT PAVING OR PLANTING 3000 PSI CONCRETE BACKING FULL LENGTH OF CURB, FORCE CONCRETE THROUGH BACK OF JOINTS, GROUT FRONT AND TOP OF JOINTS FLUSH W/ 1:2 MORTOR MIX 1:3:6 DRY MIX UNIFORM PILES AT EACH END AND ON 3 FOOT CENTERS BENEATH CURB FOR FULL LENGTH OF CURB NOTES RADIUS CURBING SHALL BE USED ON ALL RADII LESS THAN 100 FEET.6 1/8"1'-4 1/4"3"1'-3" MIN.4"1'-0"2'-8"4X4 LARCH WOOD POSTS 12" DRY PACKED CEMENT 1'-0" 1X6 LARCH WOOD 4'-0"#1 WASHED GRAVEL ELEVATION SECTION NOTE: SEAL POST W/ ROOFING CEMENT BELOW GRADE LEAVING END GRAIN UNSEALED5'-6"3 1/2"6'-6"3 1/2" 1X3 LARCH WOOD LATCH, SEE SPEC HINGE AT INT. FACE, SEE SPEC Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD As indicated6/12/2019 3:31:20 PMC:\Users\Steven\Documents\2018015 - 327 W.Seneca Street - Site_stevenPUFGL.rvtL501 SITE DETAILS 2018015327 WEST SENECA ST.06/18/2019VISUM DEVELOPMENTCITY OF ITHACA, NYDESIGN DEVELOPMENT 1" = 1'-0"A2 TYPICAL LIGHT DUTY CONCRETE WALK 1" = 1'-0"B2 TYPICAL HEAVY DUTY CONCRETE WALK 1" = 1'-0"C3 TYPICAL CONCRETE JOINTS 1/2" = 1'-0"B3 TYPICAL CONCRETE BROOM FINISH 1" = 1'-0"B1 TYPICAL ASPHALT PATCH DETAIL 1/2" = 1'-0"C1 BIKE RACK 1/4" = 1'-0"A1 CURB RAMP - TYPE A 1/2" = 1'-0"D2 TYPICAL TREE PLANTING 1/2" = 1'-0"D1 TYPICAL PERENNIAL PLANTING 1 1/2" = 1'-0"C2 GRAVEL MULCH AT BUILDING PERIMETER 1" = 1'-0"B6 TYPICAL PAVER DETAIL 1" = 1'-0"B4 GRANITE CURB 1/2" = 1'-0"D3 TRASH ENCLOSURE WALL GENERAL SHEET NOTES - DETAILS 1 Refer to Specifications, DIVISION 01, for additional information and requirements. REVISIONS Δ DESCRIPTION DATE 3 " / 1 2 "5'-5 1/2"8'-0"6'-7 5/8"10'-5" 2" GAP, TYP. 2X6 2X3 5'-0"D3 L502 3'-0"4'-0"3'-0"4'-0"GRAVEL BASE 1. SUBMIT PRODUCT SAMPLES AND CUTSHEETS FOR ALL FINISHES INCLUDING TRIM PROFILES. 2. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS. GENERAL SHEET NOTES -DETAILS PAVERS GRAVEL LAWN SEE SPEC FOR BIKE LOCK ASPHALT SHINGLE ROOF OVER ICE AND WATER UNDERLAYMEMT OVER 5/8" PLYWOOD WITH METAL DRIP EDGE AT PERIMETER TO MATCH MAIN BUILDING 4x4 LARCH POST 1X6 LARCH 1X3 LARCH Project # Date STREAM Collaborative architecture + landscape architecture dpc 123 S. Cayuga St Suite 201 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD As indicated6/12/2019 3:39:39 PMU:\2018015 - 327 W. Seneca St - Visum\06.0 DRAWINGS\REVIT\BIKE SHED.rvtL502 BIKE SHED 2018015327 WEST SENECA ST.06/18/2019VISUM DEVELOPMENTCITY OF ITHACADESIGN DEVELOPMENT REVISIONS Δ DESCRIPTION DATE 1/2" = 1'-0"D2 EAST - ELEVATION 1/2" = 1'-0"D1 NORTH - ELEVATION 1/2" = 1'-0"C1 SOUTH - ELEVATION 1" = 1'-0"B1 FLOOR PLAN 1/2" = 1'-0"D3 EAST-SECTION 1/2" = 1'-0"C2 WEST - ELEVATION 4X4 POST @ 42" BELOW GRADE NORTH 0'1'6" DW DW DW DW A203D1 A202 D1 A201 D1 A203 B1 70'-6 1/2"36'-6"D1 A302 D1 A302 UP UNIT 103UNIT 102 UNIT 104 UNIT 101 MECH. C104 BEDROOM 1 C106 BEDROOM 2 C107 CLO. C108 MECH. 102 MECH. B104 CLO. B105 BEDROOM 1 B106 BEDROOM 2 B107 LIVING/ DINING A101 BATH A105 BATH B103 BATH C103 LIVING/ DINING D101 CLO. C105 BATH D105 CLO. B108 KITCHEN D102 12'-5"2'-4"16'-9 1/4"6'-7"16'-9 1/4"2'-4"12'-5" 11'-8 1/2"4'-0"4'-3" 10'-7" 8'-2 3/4"2'-1 1/4"27'-6 3/4"4'-7 1/2"38'-4" 4'-10"5'-3"8'-8 1/4"3'-4"3'-4"4'-8"4'-7 1/2"5'-3 1/2"10'-0"5'-3"20'-6 1/2"15'-11 1/2"21'-7"3'-4"5'-3"6'-1"4'-5"5'-3"3'-4"21'-7"5'-3"10'-0"5'-3"4'-8"3'-4"3'-4"4'-8"3'-2" C101A C101B C107 C106 D101C D101B D101A D100D104D105C106 C107C108C100102B100B101AB101BB108B107 B106 B104B105B106 B107 A100 A105100A101A A101B C104 70'-10" E3 E2 E2 E1 E2E1 P3 P3 P3 P3 P3 P3 P1 P3 P1 P1 P1 P1 P1 P1 P1 P2 P1 E1 P1 P3 P3 P1 P1 P1 P1 P1 P1 P2 P1 P3 P1 E4 E2 P1A501 C2 A501 B2 A501 C2 SIM. OPP. HAND A501 B1 A501 D1 4'-3"4'-4"11'-8"B103C103R @ 6 1/4"18 11" TREAD TRASH TOTES A204 CLO. D104 REF. KITCHEN A102 SLEEPING A103 CLO. A104 P1 SLEEPING D103 KITCHEN B102 LIVING/ DINING B101 LIVING/ DINING C101 KITCHEN C102 A204 D1 P1 2'-2"36'-6"C3 A301 C3 A301 P2P2 B1 A302 B1 A302 P1 P1 C105P3 REF. REF.REF. P1 P1 P1 E1 9'-7 3/4"9'-7 3/4"16'-0"STAIR ENTRY 100 STAIR 101 P1 P3 W/DW/D W/D W/D E2 A204 A204 B1 A204 C3 A204 D3 12'-10"A1046'-9 1/2"6'-9 1/2"6'-9 1/2"3'-2 1/2"WH WH RANGE RANGERANGE RANGE WH WH D2 C2 3 3/4" DS DS DS DS DS DS DS 8'-2 3/4"OPENING5'-0"9'-7 3/4"9'-7 3/4"16'-0"10'-7"15'-8 1/2"16'-0"11'-1 1/2" 2'-2"OPENING5'-0"3'-8"3'-8"3'-8"3'-8"2'-2"C1 A301 C1 A30120' - 4 5/16"Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1/4" = 1'-0"6/22/2020 10:09:16 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA101 FIRST FLOOR PLAN 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/4" = 1'-0"C1 1ST FLOOR PLAN NORTHGENERAL SHEET NOTES - PLANS 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 Refer to wall schedules for wall and partition types, components, fire resistance, etc. 3 Exterior walls are 1-hour fire rated. See wall schedule. 4 All dimensions are to the face of studs, masonry or concrete, unless noted otherwise. 5 Unless noted otherwise, all gypsum wall board (GWB) shall be ⅝”, Type ‘X’. 6 Provide cement backing board in lieu of GWB at wall surfaces scheduled to receive ceramic, porcelain or stone tiles. 7 Unless noted otherwise, all partitions shall extend to underside of deck or structure above. 8 Unless noted otherwise, space control joints in GWB walls and ceilings as required by ASTM C 840. 9 Floor elevation 0.00 is equivalent to elevation FFE on Site/Civil Plans. 10 Layout of one unit is the same as other similar units unless noted otherwise. 11 Third floor framing dimensions are identical to second floor U.N.O. BATHROOMS 1 Provide moisture and mold resistant GWB in toilets, bathrooms, and other ‘wet’ locations. 2 “Type A” bathrooms are those that shall meet the accessibility requirements of Section 1003.11 of ICC A117.1 (Accessible and Usable Buildings and Facilities). Provide concealed blocking as required for installation of grab bars in the future. 3 Provide concealed blocking to support towel bars, robe hooks, toilet paper holder and similar wall-mounted accessories. KITCHENS 1 Submit shop drawings showing casework and appliances, prior to ordering. 2 Adjust placement of appliances to permit complete and unobstructed opening of doors. 3 For appliances with reversible doors, coordinate swing direction with Architect prior to installation. OPENINGS 1 Refer to door and window schedules for types, sizes, fire resistance and additional information. 2 Doors are centered on rooms, or 6" from wall on hinge side, unless noted otherwise. 3 Provide access doors as required to reach MEP items requiring maintenance or adjustment. Coordinate type and size with MEP trades. 4 Provide double studs at all door jambs. 5 Provide (2) 2x6 headers (or steel stud equivalent) over windows and single door openings, unless noted otherwise. 6 Provide concealed blocking behind door wall stops, and install stops as soon as practical, to prevent damage to walls. STAIRS AND RAILINGS 1 Unless noted otherwise, stair treads shall be ≥11”and stair risers ≤7”. Provide nosings as shown on drawings (or, if not shown, as required by IBC Chapter 10). 2 Handrails, guardrails and grab bars shall resist loads described in IBC Section 1607.8. REVISIONS Δ DESCRIPTION DATE 1 REVISION 1 06/22/20 DW DW DW DW A203D1 A202 D1 A201 D1 A203 B1 C1 A301 C1 A301 D1 A302 D1 A302 UP LIVING/ DINING C201 BEDROOM 1 C205 BEDROOM 2 C206 CLO. C207 BATH C208 KITCHEN D201 BATH D202 CLO. D204 BATH B208 BEDROOM 1 B205 BEDROOM 2 B206 CLO. B207 CLO. B204 MECH/ LDRY A203 BATH A202CLO. A204 ALL, U.N.O VARIES UNIT 203UNIT 202 UNIT 204UNIT 201 C206 C205C207 C204D202B206 B205 B207B204A202C208B208D200C200B200C203 D204A204B206A B205 A205B A205A C206 C205 D205C D205A D205B B201A B201CB201B C201A C201CC201BB206B D205DA205CA203D20320120011'-5 1/2"15'-11 1/4"7'-10 3/4"12'-5"2'-4"14'-5"5'-5"5 1/2"5'-5"14'-5"2'-4"12'-5"16'-0"9'-7 3/4"9'-7 3/4"3'-3"5'-7"2'-9"7'-7 1/4" 8'-1"10'-2"3'-4"3'-4"21'-0"3'-4"3'-4"18'-3"3'-4"3'-4"9'-4"5'-3"10'-0"5'-3"4'-8"3'-4"3'-4"4'-8"5'-3"10'-0"5'-3"9'-10"13'-4 1/2"6'-8"11'-3"5'-11"13'-7 1/2"9'-10" E2 E2 E2 E2 E2 P3 P3 P3 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 E2 P2 P2 R @ 6 1/4"18 11" TREAD MECH/ LDRY D203 LIVING/ SLEEPING D205 A200 P3 LIVING/ SLEEPING A205 P1 LIVING/ DINING B201 KITCHEN B202 KITCHEN C202 REF. REF.REF. REF. A204 C1 C3 A301 C3 A301 B1 A302 B1 A302 70'-10"36'-6"16'-0"20'-6"P1 P3P3 P1 P1 9'-7 3/4"9'-7 3/4"16'-0"KITCHEN A201 CLO. B203 CLO. C203 CLO. C204 W/DW/D B203 A203 D203 W/D W/D A204B2 WH WHWH WH 3'-8"3'-8"RANGE RANGERANGE RANGE 5'-7"3'-3"P1 ELEC. PANEL 4"5'-3"A2043'-8"3'-8"7'-7 1/4"2'-9" 6'-3" 4'-1 1/4"4'-1 1/4"6'-3" DS DS DS DS DS DS DS 15'-5"3'-2 1/2"3'-0"5'-6"3'-0"5'-6" 3'-0"5'-6"2' - 0 3/4" A2 2' - 6" Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1/4" = 1'-0"6/22/2020 10:09:18 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA102 SECOND FLOOR PLAN 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/4" = 1'-0"C1 FLOOR PLAN - 2ND FLOOR NORTHGENERAL SHEET NOTES - PLANS 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 Refer to wall schedules for wall and partition types, components, fire resistance, etc. 3 Exterior walls are 1-hour fire rated. See wall schedule. 4 All dimensions are to the face of studs, masonry or concrete, unless noted otherwise. 5 Unless noted otherwise, all gypsum wall board (GWB) shall be ⅝”, Type ‘X’. 6 Provide cement backing board in lieu of GWB at wall surfaces scheduled to receive ceramic, porcelain or stone tiles. 7 Unless noted otherwise, all partitions shall extend to underside of deck or structure above. 8 Unless noted otherwise, space control joints in GWB walls and ceilings as required by ASTM C 840. 9 Floor elevation 0.00 is equivalent to elevation FFE on Site/Civil Plans. 10 Layout of one unit is the same as other similar units unless noted otherwise. 11 Third floor framing dimensions are identical to second floor U.N.O. BATHROOMS 1 Provide moisture and mold resistant GWB in toilets, bathrooms, and other ‘wet’ locations. 2 “Type A” bathrooms are those that shall meet the accessibility requirements of Section 1003.11 of ICC A117.1 (Accessible and Usable Buildings and Facilities). Provide concealed blocking as required for installation of grab bars in the future. 3 Provide concealed blocking to support towel bars, robe hooks, toilet paper holder and similar wall-mounted accessories. KITCHENS 1 Submit shop drawings showing casework and appliances, prior to ordering. 2 Adjust placement of appliances to permit complete and unobstructed opening of doors. 3 For appliances with reversible doors, coordinate swing direction with Architect prior to installation. OPENINGS 1 Refer to door and window schedules for types, sizes, fire resistance and additional information. 2 Doors are centered on rooms, or 6" from wall on hinge side, unless noted otherwise. 3 Provide access doors as required to reach MEP items requiring maintenance or adjustment. Coordinate type and size with MEP trades. 4 Provide double studs at all door jambs. 5 Provide (2) 2x6 headers (or steel stud equivalent) over windows and single door openings, unless noted otherwise. 6 Provide concealed blocking behind door wall stops, and install stops as soon as practical, to prevent damage to walls. STAIRS AND RAILINGS 1 Unless noted otherwise, stair treads shall be ≥11”and stair risers ≤7”. Provide nosings as shown on drawings (or, if not shown, as required by IBC Chapter 10). 2 Handrails, guardrails and grab bars shall resist loads described in IBC Section 1607.8. REVISIONS Δ DESCRIPTION DATE DWDW DWDW A203D1 A202 D1 A201 D1 A203 B1 C1 A301 C1 A301 D1 A302 D1 A302 DN UNIT 303UNIT 302 UNIT 304UNIT 301 LIVING/ DINING C301 KITCHEN C302 BEDROOM 2 C306 CLO. C307 BEDROOM 1 C305 CLO. C304 CLO. D303 BATH D302 CLO. C303 CLO. B304 KITCHEN B302 BATH B308 BATH C308 CLO. B303 CLO. B307BEDROOM 2 B306 BEDROOM 1 B305 LIVING/ SLEEPING A305 CLO. A304 BATH A302 BEDROOMS BEDS C306 C305C307 C304D302B306 B305 B307B304A302C308B308D300C300B300A300 B306A B305 A305B A305A C306 C305 D305B D305D D305C B301A B301CB301B C301A C301CC301BB306B D305AA305CA302D302301300D303A304E2 E2 E2 E2 E2 P3 P3 P3 P3 P1 P1 P1 P1 P1 P1 P2 P1 P3 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 E2 KITCHEN D301 P3 P3 P1P1 C3 A301 C3 A301 B1 A302 B1 A302 REF.REF. REF.REF. LIVING/ DINING B301 P1P1 P1 P1 P1 P1 P3 P1 P1 KITCHEN A301 MECH./ LDRY A303 LIVING/ SLEEPING D305 A303 B303C303D304 MECH./ LDRY D304 WHWH WHWH W/D W/D W/DW/D P1 DS DS DS DS DS DS DS ATTIC ACCESSATTIC ACCESS D3 A302 D3 A302 B3 A302 B3 A302 Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1/4" = 1'-0"6/22/2020 10:09:20 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA103 THIRD FLOOR PLAN 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/4" = 1'-0"C1 FLOOR PLAN - 3RD FLOOR GENERAL SHEET NOTES - PLANS 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 Refer to wall schedules for wall and partition types, components, fire resistance, etc. 3 Exterior walls are 1-hour fire rated. See wall schedule. 4 All dimensions are to the face of studs, masonry or concrete, unless noted otherwise. 5 Unless noted otherwise, all gypsum wall board (GWB) shall be ⅝”, Type ‘X’. 6 Provide cement backing board in lieu of GWB at wall surfaces scheduled to receive ceramic, porcelain or stone tiles. 7 Unless noted otherwise, all partitions shall extend to underside of deck or structure above. 8 Unless noted otherwise, space control joints in GWB walls and ceilings as required by ASTM C 840. 9 Floor elevation 0.00 is equivalent to elevation FFE on Site/Civil Plans. 10 Layout of one unit is the same as other similar units unless noted otherwise. 11 Third floor framing dimensions are identical to second floor U.N.O. BATHROOMS 1 Provide moisture and mold resistant GWB in toilets, bathrooms, and other ‘wet’ locations. 2 “Type A” bathrooms are those that shall meet the accessibility requirements of Section 1003.11 of ICC A117.1 (Accessible and Usable Buildings and Facilities). Provide concealed blocking as required for installation of grab bars in the future. 3 Provide concealed blocking to support towel bars, robe hooks, toilet paper holder and similar wall-mounted accessories. KITCHENS 1 Submit shop drawings showing casework and appliances, prior to ordering. 2 Adjust placement of appliances to permit complete and unobstructed opening of doors. 3 For appliances with reversible doors, coordinate swing direction with Architect prior to installation. OPENINGS 1 Refer to door and window schedules for types, sizes, fire resistance and additional information. 2 Doors are centered on rooms, or 6" from wall on hinge side, unless noted otherwise. 3 Provide access doors as required to reach MEP items requiring maintenance or adjustment. Coordinate type and size with MEP trades. 4 Provide double studs at all door jambs. 5 Provide (2) 2x6 headers (or steel stud equivalent) over windows and single door openings, unless noted otherwise. 6 Provide concealed blocking behind door wall stops, and install stops as soon as practical, to prevent damage to walls. STAIRS AND RAILINGS 1 Unless noted otherwise, stair treads shall be ≥11”and stair risers ≤7”. Provide nosings as shown on drawings (or, if not shown, as required by IBC Chapter 10). 2 Handrails, guardrails and grab bars shall resist loads described in IBC Section 1607.8.NORTHREVISIONS Δ DESCRIPTION DATE D1 A302 D1 A3026" / 12"6" / 12"6" / 12"6" / 12"B1 A302 B1 A302 RIDGE VENTTYP.2'-0"ICE + WATER SHIELD, TYP. ENTIRE ROOF PERIMETER LINE OF BUILDING BELOW RIDGE VENT GUTTER GUTTER D3 A302 D3 A302 B3 A302 B3 A302 Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1/4" = 1'-0"6/22/2020 10:09:21 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA104 ROOF PLAN 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/4" = 1'-0"C1 ROOF PLAN GENERAL SHEET NOTES - ROOFING 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 Review MEP drawings to determine exact quantity, type and location of roof penetrations.NORTHREVISIONS Δ DESCRIPTION DATE GFI @ 42 GFI @ 42 GFI @ 42220 GFI @ 42GFI @ 42220GFI @ 42GFI GFI @ 42GFI220 GFI @ 42GFI @ 42GFI @ 42 220 GFI @ 42GFI @ 42 220GFI @ 42GFIGFI @ 42GFI220 220220GFIGFIGFI GFI BEDROOM 2 B107 BEDROOM 1 B106 LIVING/ DINING A101 BATH A105 BEDROOM 2 C107 BEDROOM 1 C106 KITCHEN D102 LIVING/ DINING D101 BATH D105 BATH C103BATH B103 MECH. STAIR ENTRY LIVING/ DINING B101 LIVING/ DINING C101 KITCHEN C102 KITCHEN B102 KITCHEN A102 SLEEPING A103 SLEEPING D103 STAIR 101 B A BB B B B B B B B B A A A AAAAAA B DD D D A A A AAA A E CC CC E A F F F F F F FFFFF ALL STAIR ENTRY, STAIR, AND CORRIDOR LIGHTING TO REMAIN ON AT ALL TIMES AND CIRCUITED TO EMERGENCY PANELBOARD IN MECH.RM. CLO. B108 CLO. B105 MECH. B104 CLO. D104 CLO. A104 CLO. C105MECH. C104 CLO. C108 BIKE SHED FFF 8' BASEBOARD TYP. 4' BASEBOARD TYP. 5'-10"5'-9 1/4" ELEC. PANEL 6'-8" T.O. WALL OPENING WALL HEATER TIME CLOCK FOR EXTERIOR LIGHTS, CIRCUIT TO EMERGENCY PANELBOARD. WALL HEATER WALL HEATER WALL HEATER ELEC. PANEL ELEC. PANEL ELEC. PANEL Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1/4" = 1'-0"6/22/2020 10:09:22 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA105 FIRST FLOOR ELECTRIC PLAN 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/4" = 1'-0"C1 RCP - 1ST FLOOR GENERAL SHEET NOTES - RCP/ Electrical 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 Submit shop drawings showing layout of fire alarm/ detector/ sprinkler system (Delegated Design) prior to start of construction. 3 Coordinate location of sprinkler heads, light fixtures, HVAC grilles and similar items with MEP drawings. 4 Provide access doors as required to reach MEP items requiring maintenance or adjustment. Coordinate type and size with MEP trades. 5 Unless noted otherwise, light fixtures shall be centered in the room or area they serve. If more than one, they shall be installed symmetrically, as shown or implied on drawings. 6 Security system devices and wiring is Delegated Design by security subcontractor. 7 Data or wirelessaccess point devices and wiring is Delegated Design by elec. subcontractor or service provider. 8 Any notes on the C/D units apply to A/B side as well. 9 At first floor bathrooms and bedrooms, provide all necessary wiring and accessoris for future installation of emergency strobes and signals required for ADA compliance. LIGHTING FIXTURE SCHEDULE Type Manufacturer Model FINISH A Amax led-sm7dl/nkl White AUX-LED Cooper Lighting AUX Series B Lithonia fmlrl-11-148-35 White C Style Selections vbl10lbnk White D Panasonic fv-11vqcl6 White E Cooper Lighting 23DW White EM Cooper Industries, Inc. Model F RAB Lighting VXBRLED13DG Black REVISIONS Δ DESCRIPTION DATE 220220GFI @ 42GFI @ 42GFI @ 42GFI 220 220 GFI GFI GFI @ 42 GFI @ 42 GFI @ 42220 GFIGFIGFI @ 42 220 GFI @ 42GFI @ 42 GFI @ 42 220 GFI @ 42 GFI @ 42 GFI @ 42GFI @ 42GFI @ 42GFI @ 42GFI @ 42GFI @ 42220BEDROOM 2 B206 CLO. B207 BEDROOM 1 B205 CLO. B204 KITCHEN B202 CLO. C203 BATH B208 BATH C208 LIVING/ DINING C201 KITCHEN D201 KITCHEN C202 BEDROOM 1 C205 BEDROOM 2 C206 CLO. C207 CLO. D204 BATH D202 ALL, U.N.O BATH A202 MECH/ LDRY A203 CLO. A204 LIVING/ DINING B201 LIVING/ SLEEPING D205 LIVING/ SLEEPING A205 CLO. B203 CLO. C204 BB B B B B B B B B BB D E AAA A A A A A A AA AA AA A A A A C C DD C C D A A KITCHEN A201 ALL STAIR ENTRY,STAIR,AND CORRIDOR LIGHTING TO REMAIN ON AT ALL TIMES AND CIRCUITED TO EMERGENCY PANELBOARD ,EM ,EM ,EM ,EM EXIT SIGN MECH/ LDRY D203 8' BASEBOARD TYP. 4' BASEBOARD TYP. WALL HEATER EXIT SIGN ELEC. PANEL ELEC. PANEL E,EM ELEC. PANEL WALL HEATER WALL HEATER Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1/4" = 1'-0"6/22/2020 10:09:23 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA106 SECOND FLOOR ELECTRIC PLAN 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/4" = 1'-0"C1 RCP - 2ND FLOOR GENERAL SHEET NOTES - RCP/ Electrical 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 Submit shop drawings showing layout of fire alarm/ detector/ sprinkler system (Delegated Design) prior to start of construction. 3 Coordinate location of sprinkler heads, light fixtures, HVAC grilles and similar items with MEP drawings. 4 Provide access doors as required to reach MEP items requiring maintenance or adjustment. Coordinate type and size with MEP trades. 5 Unless noted otherwise, light fixtures shall be centered in the room or area they serve. If more than one, they shall be installed symmetrically, as shown or implied on drawings. 6 Security system devices and wiring is Delegated Design by security subcontractor. 7 Data or wirelessaccess point devices and wiring is Delegated Design by elec. subcontractor or service provider. 8 Any notes on the C/D units apply to A/B side as well. 9 At first floor bathrooms and bedrooms, provide all necessary wiring and accessoris for future installation of emergency strobes and signals required for ADA compliance. LIGHTING FIXTURE SCHEDULE Type Manufacturer Model FINISH A Amax led-sm7dl/nkl White AUX-LED Cooper Lighting AUX Series B Lithonia fmlrl-11-148-35 White C Style Selections vbl10lbnk White D Panasonic fv-11vqcl6 White E Cooper Lighting 23DW White EM Cooper Industries, Inc. Model F RAB Lighting VXBRLED13DG Black REVISIONS Δ DESCRIPTION DATE GFI GFI 220220GFI GFI @ 42 GFI @ 42 GFI @ 42 GFIGFI @ 42GFI @ 42GFI @ 42220220 220 GFI @ 42GFI @ 42GFI @ 42GFI @ 42GFIGFI @ 42GFI @ 42GFI @ 42 GFI GFI @ 42GFI @ 42GFI @ 42220220 220GFIGFIPROVIDE DRAFTSTOPPING IN ATTIC TO UNDERSIDE OF ROOF DECK. PROVIDE A 48" X 48" OPENING, COVERED WITH A REMOVABLE PANEL, TO ALLOW ENTRY INTO SOUTH HALF OF ATTIC LIVING/ SLEEPING A305 CLO. A304 BATH A302 CLO. B303 BEDROOMS BATH D302 CLO. D303 MECH./ LDRY D304 CLO. C303 LIVING/ DINING C301 KITCHEN B302 KITCHEN C302 CLO. C304 BEDROOM 1 C305 BEDROOM 2 C306 CLO. C307 BATH C308 BATH B308CLO. B307 BEDROOM 2 B306 BEDROOM 1 B305 CLO. B304 LIVING/ SLEEPING D305 KITCHEN D301 KITCHEN A301 MECH./ LDRY A303 B B B B B BB B B B B B DD AA A AA A A A AAA A A A A A A A E E C C C C A A A D D 24" x 36" ATTIC HATCH LIVING/ DINING B301 ALL STAIR ENTRY, STAIR, AND CORRIDOR LIGHTING TO REMAIN ON AT ALL TIMES AND CIRCUITED TO EMERGENCY PANELBOARD ,EM ,EM ,EM , EM ,EM WALL HEATER 8' BASEBOARD TYP. 4' BASEBOARD TYP. ELEC. PANEL EXIT SIGN WALL HEATER WALL HEATER WALL HEATER ELEC. PANEL ELEC. PANEL Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1/4" = 1'-0"6/22/2020 10:09:25 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA107 THIRD FLOOR ELECTRIC PLAN 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/4" = 1'-0"C1 RCP - 3RD FLOOR GENERAL SHEET NOTES - RCP/ Electrical 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 Submit shop drawings showing layout of fire alarm/ detector/ sprinkler system (Delegated Design) prior to start of construction. 3 Coordinate location of sprinkler heads, light fixtures, HVAC grilles and similar items with MEP drawings. 4 Provide access doors as required to reach MEP items requiring maintenance or adjustment. Coordinate type and size with MEP trades. 5 Unless noted otherwise, light fixtures shall be centered in the room or area they serve. If more than one, they shall be installed symmetrically, as shown or implied on drawings. 6 Security system devices and wiring is Delegated Design by security subcontractor. 7 Data or wirelessaccess point devices and wiring is Delegated Design by elec. subcontractor or service provider. 8 Any notes on the C/D units apply to A/B side as well. 9 At first floor bathrooms and bedrooms, provide all necessary wiring and accessoris for future installation of emergency strobes and signals required for ADA compliance. LIGHTING FIXTURE SCHEDULE Type Manufacturer Model FINISH A Amax led-sm7dl/nkl White AUX-LED Cooper Lighting AUX Series B Lithonia fmlrl-11-148-35 White C Style Selections vbl10lbnk White D Panasonic fv-11vqcl6 White E Cooper Lighting 23DW White EM Cooper Industries, Inc. Model F RAB Lighting VXBRLED13DG Black REVISIONS Δ DESCRIPTION DATE 1ST SUB FLOOR 396.62' 2ND FLOOR SUB FLOOR 406.04' 3RD FLOOR SUB FLOOR 415.45' TOP OF 3RD STORY TOP PLATE 423.87' MAIL BOXES,SEE SPEC.SEE DETAIL D3/L501 METAL CANOPY, SEE SPEC. EXTERIOR LIGHT, SEE ELECTRICAL PLAN (CENTER BETWEEN BATTENS) BOARD AND BATTEN SIDING 1X8 TRIM DOUBLE HUNG WINDOW MODIFIED VENEER STUCCO ROUND RAIN LEADER ASPHALT SHINGLES MODIFIED VENEER STUCCOWOOD RAILING 8'-5"9'-5"9'-5"D3 A302 D3 A302 B3 A302 B3 A302 Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1/4" = 1'-0"6/22/2020 10:09:41 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA201 ELEVATION -WEST 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/4" = 1'-0"D1 ELEVATION - WEST GENERAL SHEET NOTES - ELEVATIONS 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 Coordinate exterior elevation work with floor plans, window schedule and door schedule. 3 See schedules for head heights - coordinate adjacent window and door rough openings to ensure alignment of head casings. 4 Coordinate location of safety glazing with Architect, prior to ordering doors or windows. 5 Coordinate quantity, location and type of Window Operation Control Devices (WOCD) with Architect, prior to ordering windows. 6 Coordinate exterior elevation work with MEP drawings. Unless noted otherwise, center light fixtures, louvers and similar items on door and window openings. Consult Architect prior to roughing in. REVISIONS Δ DESCRIPTION DATE 1ST SUB FLOOR 396.62' 2ND FLOOR SUB FLOOR 406.04' 3RD FLOOR SUB FLOOR 415.45' TOP OF 3RD STORY TOP PLATE 423.87' DOWNSPOUTFIRE SHUTTERFIRE SHUTTER A502 D3 C2 A502 B2 A502 A1 A502 D2 A502 D1 A502 B2 A502 9' - 5"9' - 5"8' - 5"D3 A302 D3 A302 B3 A302 B3 A302 Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1/4" = 1'-0"6/22/2020 10:10:03 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA202 ELEVATION -EAST 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/4" = 1'-0"D1 ELEVATION - EAST GENERAL SHEET NOTES - ELEVATIONS 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 Coordinate exterior elevation work with floor plans, window schedule and door schedule. 3 See schedules for head heights - coordinate adjacent window and door rough openings to ensure alignment of head casings. 4 Coordinate location of safety glazing with Architect, prior to ordering doors or windows. 5 Coordinate quantity, location and type of Window Operation Control Devices (WOCD) with Architect, prior to ordering windows. 6 Coordinate exterior elevation work with MEP drawings. Unless noted otherwise, center light fixtures, louvers and similar items on door and window openings. Consult Architect prior to roughing in. REVISIONS Δ DESCRIPTION DATE 1ST SUB FLOOR 396.62' 2ND FLOOR SUB FLOOR 406.04' 3RD FLOOR SUB FLOOR 415.45' TOP OF 3RD STORY TOP PLATE 423.87' 1ST SUB FLOOR 396.62' 2ND FLOOR SUB FLOOR 406.04' 3RD FLOOR SUB FLOOR 415.45' TOP OF 3RD STORY TOP PLATE 423.87'8'-5"9'-5"9'-5"Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1/4" = 1'-0"6/22/2020 10:10:29 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA203 ELEVATIONS- NORTH/ SOUTH 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/4" = 1'-0"B1 ELEVATION - NORTH GENERAL SHEET NOTES - ELEVATIONS 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 Coordinate exterior elevation work with floor plans, window schedule and door schedule. 3 See schedules for head heights - coordinate adjacent window and door rough openings to ensure alignment of head casings. 4 Coordinate location of safety glazing with Architect, prior to ordering doors or windows. 5 Coordinate quantity, location and type of Window Operation Control Devices (WOCD) with Architect, prior to ordering windows. 6 Coordinate exterior elevation work with MEP drawings. Unless noted otherwise, center light fixtures, louvers and similar items on door and window openings. Consult Architect prior to roughing in. 1/4" = 1'-0"D1 ELEVATION - SOUTH REVISIONS Δ DESCRIPTION DATE REF. RANGE MIC DW 12 34.5 2415 34.5 24 15 30 12 15 12 1215 12 12 15 12 12 15 12 12 12 30 12 15 24 12 15 24 12 12 30 12 12 30 12 30 34.5 24 15 12 12 15 12 12 12 30 12 12 30 12 15 24 12 15 24 12 15 12 12 15 12 12 21 30 12 DW 30 34.5 24 21 34.5 24 REF. RANGE MIC 12 30 12 12 30 12 15 24 1215 24 12 15 30 12 15 12 1215 12 12 18 30 12 15 12 1215 12 12 DW 30 34.5 24 15 34.5 2418 34.5 24 REF. RANGE MIC72"15"15"28"A204 W/D P3 P1 P3 P3 P2 1'-3"2' - 6"2'-6" 4 '-0 " D2 BATH C103 PROVIDE BLOCKING FOR FUTURE GRAB BARS, TYP. (GRAB BARS N.I.C) A204 P3 P2 P1 E1 E11'-3"1'-3"2 ' - 6 " 2'- 6 "4'-0 "BATH A105 C25'-0 1/2"10'-7 1/2"72"MIN 8" MIN 11" MAX 6"MIN9"27" MIN34" MAXLAVATORY OR VANITY SINK COUNTER WHERE OCCURS MIN 15"LAV AS SPECIFIED6" 12" MAXMIN 42" 59" MIN CLR 1.5" DIA GRAB BAR W/ 1.5" GAP FROM WALL 33" - 36"1'-5" - 1'-7"16"-18" WATER CLOSET SIDE WALL WATER CLOSET BACK WALLMIN18"39"-41"MIN. 24" PROVIDE BLOCKING FOR FUTURE GRAB BARS Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1/2" = 1'-0"6/22/2020 10:10:32 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA204 ENLARGED PLANS AND INTERIOR ELEVS 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/2" = 1'-0"C1 KITCHEN- C202/ C302 (A202/ A203/ D202/ D203 SIM. B202/ B302 OPP. HAND) 1/2" = 1'-0"D1 KITCHEN- A102 (D102 OPP. HAND) GENERAL SHEET NOTES - INTERIORS 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 3 1/2" = 1'-0"B1 KITCHEN- C102 (B102 OPP. HAND) 1/2" = 1'-0"B2 INT. ELEVATION-BATHROOM C208/ C308 (B208/ C208 OPP. HAND) 1/2" = 1'-0"D3 FLOOR PLAN - ADA BATHROOM C103 1/2" = 1'-0"C3 FLOOR PLAN - ADA BATHROOM A105 1/2" = 1'-0"D2 INT.ELEVATION - ADA BATHROOM C103 (B103 OPP. HAND) 1/2" = 1'-0"C2 INT. ELEVATION- ADA BATHROOM A105 (D105 OPP. HAND) 1/2" = 1'-0"B3 TYPICAL PLUMBING FIXTURES AND ACCESSORIES 1/2" = 1'-0"A2 INT. ELEVATION BATHROOM D202 (A202 OPP. HAND) REVISIONS Δ DESCRIPTION DATE 1ST SUB FLOOR 396.62' TOP OF 1ST STORY PLATE 405.00' 2ND FLOOR SUB FLOOR 406.04' 3RD FLOOR SUB FLOOR 415.45' TOP OF 3RD STORY TOP PLATE 423.87' TOP OF 2ND STORY PLATE 414.43' LIVING/ SLEEPING A305 LIVING/ SLEEPING A205 LIVING/ DINING A101 BATH A105 BATH A202 BATH A302 ALL, U.N.O BEDROOMS STAIR ENTRY BATH D302 BATH D202 BATH D105 LIVING/ SLEEPING D205 LIVING/ DINING D1018'-5"1'-0 1/4"8'-4 3/4"1'-0 1/2"8'-4 1/2"A502 B2 A502 B1 A502 D2 A501 C1 A501 D2 A501 A1 A401 C1 A401 D1 LIVING/ SLEEPING D305 DRAFTSTOPPING IN ATTIC 3'-6"8'-5"9'-5"9'-5"11-7/8" I-JOISTS W/ 3/4" SHEATHING 1ST SUB FLOOR 396.62' TOP OF 1ST STORY PLATE 405.00' 2ND FLOOR SUB FLOOR 406.04' 3RD FLOOR SUB FLOOR 415.45' TOP OF 3RD STORY TOP PLATE 423.87' TOP OF 2ND STORY PLATE 414.43' BEDROOM 2 C306 BEDROOM 2 C206 BEDROOM 2 C107 LIVING/ DINING C101 LIVING/ DINING C201 LIVING/ DINING C301 BATH C308 BATH C208 BATH B208 BATH B308 MECH. 102 LIVING/ DINING B101 LIVING/ DINING B201 LIVING/ DINING B301 BEDROOM 2 B306 BEDROOM 2 B206 BEDROOM 2 B107 DRAFTSTOPPING IN ATTIC A501 B3 11-7/8" I-JOISTS W/ 3/4" SHEATHING Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1/4" = 1'-0"6/22/2020 10:10:35 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA301 SECTIONS 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/4" = 1'-0"C1 BUILDING SECTION 2 GENERAL SHEET NOTES - SECTIONS 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 Notes on one drawing, section or detail apply to all similar drawings, sections or details. 3 Floor elevation 0.00 is equivalent to elevation FFE on Site/Civil Plans. 1/4" = 1'-0"C3 BUILDING SECTION 1 REVISIONS Δ DESCRIPTION DATE 1ST SUB FLOOR 396.62' TOP OF 1ST STORY PLATE 405.00' 2ND FLOOR SUB FLOOR 406.04' 3RD FLOOR SUB FLOOR 415.45' TOP OF 3RD STORY TOP PLATE 423.87' TOP OF 2ND STORY PLATE 414.43' BATH B308 BATH B208 LIVING/ DINING B101 KITCHEN B102 BATH B103 STAIR ENTRY 100 ALL, U.N.O VARIES LIVING/ DINING B201 LIVING/ DINING B301 BEDROOMS BEDS A502 B3 TRUSS AND FLOOR FRAMING IS DELEGATED DESIGN BY FRAMING CONTRACTOR, TO BE REVIEWED BY STRUCTURAL ENGINEER PRIOR TO FABRICATION/CONSTRUCTION A501 A1 PROVIDE 48" BY 48" OPENING (TO BE CLOSED WITH PLYWOOD PANEL) TO ALLOW ACCESS TO OTHER SIDE OF ATTIC 11-7/8" I-JOISTS W/ 3/4" SHEATHING 1ST SUB FLOOR 396.62' TOP OF 1ST STORY PLATE 405.00' 2ND FLOOR SUB FLOOR 406.04' 3RD FLOOR SUB FLOOR 415.45' TOP OF 3RD STORY TOP PLATE 423.87' TOP OF 2ND STORY PLATE 414.43' BEDROOM 2 B306 BEDROOM 2 B206 BEDROOM 2 B107 BEDROOM 1 B106 BEDROOM 1 B205 BEDROOM 1 B305 LIVING/ SLEEPING A305 LIVING/ SLEEPING A205 LIVING/ DINING A101 KITCHEN A102 11-7/8" I-JOISTS W/ 3/4" SHEATHING 36' - 6" 1' - 4"1' - 4"1' - 4" 6 " / 1 2 "6" / 12" 1' - 4" 20' - 4 3/8" 1' - 4"1' - 4"6 " / 1 2 "6" / 12" Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1/4" = 1'-0"6/22/2020 10:10:36 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA302 SECTIONS 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/4" = 1'-0"D1 BUILDING SECTION 3 GENERAL SHEET NOTES - SECTIONS 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 Notes on one drawing, section or detail apply to all similar drawings, sections or details. 3 Floor elevation 0.00 is equivalent to elevation FFE on Site/Civil Plans. 1/4" = 1'-0"B1 BUILDING SECTION 4 ATTIC HATCH REVISIONS Δ DESCRIPTION DATE 1/4" = 1'-0"D3 TRUSS 01 1/4" = 1'-0"B3 TRUSS 02 122 122 122 122 1221028210262 122 42 42" AFF TOP OF WALL 36" ABOVE STAIR NOSING TOP OF RAILING 626242" AFF TOP OF WALL 3'-0"SLOPED RAILING WALL A401 C2 07 84 00.A1 2X FIRE STOPPING RUBBER STAIR TREAD & NOSING SKIRT BOARD BEYOND SEE PLANS FOR TREAD AND RISER DIMENSIONS 07 84 00.A1 2X FIRE STOPPING 06 11 00.H1 2x10 07 84 00.A1 2X FIRE STOPPING WALL TYPE PER PLAN B-GUARD WALL 1 1/2" 1 1/2" A-RAILING WALL STEEL BRACKETS AS REQ'D TO MEET IBC 1607.8 CONTINUOUS 2X BLK'G IN WALL FOR BRACKET ATTACHMENT WOOD CAP, SEE SECTIONS FOR SLOPING PORTIONS 06 46 00.E1 3/4" x 1 3/8" BASE CAP MOLDING 06 46 00.B2 3/4" x 3/4" COVE MOLDING WALL TYPE P4 BLOCKING WOOD CAP, SEE SECTIONS FOR SLOPING PORTIONS 1/4" LUAN SHEATHING 06 46 00.B2 3/4" x 3/4" COVE MOLDING 06 46 00.E1 3/4" x 1 3/8" BASE CAP MOLDING 09 29 00.A2 3/8" GYPSUM WALLBOARD 6 1/2" ONE HOUR FLOOR/CEILING ASSEMBLY: INTERTEK WNR FCA 60-03. STC 54 PER TJ-4035, ASSEMBLY B, TYP. FLOORS 2 & 3 P1 P2 E1 E2 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD 06 11 00.G1 2x8 06 16 00.D17 7/16" ZIP SYSTEM 07 48 00.A5 1X3 FURRING STRIPS 07 21 00.A8 R-30 UNFACED BATT INSULATION - MINERAL WOOL 07 46 23.D1 BOARD AND BATTEN SIDING 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD 06 11 00.G1 2x8 06 16 00.D17 7/16" ZIP SYSTEM 07 48 00.A5 1X3 FURRING STRIPS 07 21 00.A8 R-30 UNFACED BATT INSULATION - MINERAL WOOL 09 29 00.M1 CEMENTITIOUS BACKER BOARD 09 24 00.B3 MODIFIED VENEER STUCCO 07 21 00.A3 R-15 UNFACED BATT INSULATION - MINERAL WOOL P3 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD UL U327 1-HR RATED STC 50 09 29 00.D1 5/8" GYPSUM WALLBOARD 09 29 00.D1 5/8" GYPSUM WALLBOARD 09 29 00.D1 5/8" GYPSUM WALLBOARD 09 29 00.D1 5/8" GYPSUM WALLBOARD 2'-0" O.C.06 11 00.E1 2x6 09 29 00.L1 RC-1 RESILIENT CHANNEL –SINGLE LEG 06 11 00.D1 2x4 06 11 00.E1 2x6 E3 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD 06 11 00.G1 2x8 06 16 00.D17 7/16" ZIP SYSTEM 07 48 00.A5 1X3 FURRING STRIPS 07 21 00.A8 R-30 UNFACED BATT INSULATION - MINERAL WOOL 07 46 23.D1 BOARD AND BATTEN SIDING E4 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD 06 11 00.G1 2x8 06 16 00.H2 1/2”MAGNESIUM OXIDE PANEL 07 48 00.A5 1X3 FURRING STRIPS 07 21 00.A8 R-30 UNFACED BATT INSULATION - MINERAL WOOL 09 29 00.M1 CEMENTITIOUS BACKER BOARD 09 24 00.B3 MODIFIED VENEER STUCCO 1-HR RATED 1-HR RATED Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD As indicated6/22/2020 10:10:38 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA401 DETAILS 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1/2" = 1'-0"C1 STAIR GUARD- SLOPING WALL 1 1/2" = 1'-0"B1 STAIR- TREAD & RISER DETAIL 1 1/2" = 1'-0"B2 STAIR-LANDING 3" = 1'-0"C2 INTERIOR HANDRAIL AND CAPPED GUARD WALL 3" = 1'-0"D1 HALF WALL DETAIL REFERENCE KEYNOTES KEY NOTE 03 31 00.J5 4" CAST-IN-PLACE CONCRETE SLAB WITH 6x6 W2.9 x W2.9 05 05 23.E3 5/8" HOOKED ANCHOR BOLT 06 11 00.D1 2x4 06 11 00.E1 2x6 06 11 00.G1 2x8 06 11 00.H1 2x10 06 16 00.D8 5/8" PLYWOOD 06 16 00.D17 7/16" ZIP SYSTEM 06 16 00.H2 1/2” MAGNESIUM OXIDE PANEL 06 22 00.A2 1x2 WOOD TRIM 06 46 00.B2 3/4" x 3/4" COVE MOLDING 06 46 00.E1 3/4" x 1 3/8" BASE CAP MOLDING 07 21 00.A3 R-15 UNFACED BATT INSULATION - MINERAL WOOL 07 21 00.A6 R-23 UNFACED BATT INSULATION - MINERAL WOOL 07 21 00.A8 R-30 UNFACED BATT INSULATION - MINERAL WOOL 07 21 00.B6 3" XPS RIGID INSULATION 07 21 00.D1 DENSE-PACK SPRAY-APPLIED CELLULOSE INSULATION 07 24 00.A1 EIFS ON INSULATION BOARD 07 26 00.A5 CLASS III VAPOR RETARDER 07 27 00.A1 SILL SEALER 07 31 00.A1 ASPHALT SHINGLES 07 31 00.B2 ‘ICE AND WATER’ UNDERLAYMENT 07 31 00.C1 METAL DRIP EDGE 07 46 00.B1 WOOD COMPOSITE TRIM – 1x4 07 46 00.B8 WOOD COMPOSITE TRIM – 5/4x6 07 46 00.B9 WOOD COMPOSITE TRIM – 5/4x8 07 46 23.C2 FIBER CEMENT PANEL SIDING 07 46 23.C4 FIBER CEMENT SOFFIT PANEL - PERFORATED 07 46 23.D1 BOARD AND BATTEN SIDING 07 48 00.A5 1X3 FURRING STRIPS 07 48 00.B1 COR A VENT SV-5 07 62 00.A2 ALUMINUM FLASHING 07 62 00.H6 5" OGEE (K-STYLE) GUTTER 07 65 00.A3 SELF-ADHERED FLASHING 07 84 00.A1 2X FIRE STOPPING 07 92 00.A1 SEALANT – TYPE 1 (SILICONE, EXTERIOR) 07 92 00.A5 SEALANT – TYPE 5 (LATEX, INTERIOR) 07 92 00.A6 SEALANT – TYPE 6 (LATEX, ACOUSTICAL, FIRE RATED) 07 92 00.B2 BACKER ROD AND SEALANT 09 24 00.B3 MODIFIED VENEER STUCCO 09 29 00.A2 3/8" GYPSUM WALLBOARD 09 29 00.D1 5/8" GYPSUM WALLBOARD 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD 09 29 00.D12 2 LAYERS 5/8" TYPE "X" GYPSUM BOARD 09 29 00.L1 RC-1 RESILIENT CHANNEL – SINGLE LEG 09 29 00.L3 RC-3 RESILIENT CHANNEL – ‘WHISPERCLIP’ WITH HAT CHANNEL 09 29 00.M1 CEMENTITIOUS BACKER BOARD 09 65 00.A1 RESILIENT FLOORING 31 05 19.A1 FILTER MAT 31 23 00.B1 GRAVEL 31 23 00.B2 COMPACTED GRAVEL SUB-BASE 33 46 00.A3 6" PERFORATED PVC PIPE GENERAL SHEET NOTES - DETAILS 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 All 2x8 framing, 16" O.C. 3 See detail D1 for wall type P4 3/4" = 1'-0" WALL TYPES REVISIONS Δ DESCRIPTION DATE 82 82 82 6282 82626262628 2828231 313131 318282 82 8282 31 3131626262 8282 4131 418282 07 92 00.A6 SEALANT –TYPE 6 (LATEX, ACOUSTICAL, FIRE RATED) 07 21 00.A8 R-30 UNFACED BATT INSULATION - MINERAL WOOL 09 29 00.D12 2 LAYERS 5/8" TYPE "X" GYPSUM BOARD 09 65 00.A1 RESILIENT FLOORING 07 21 00.A3 R-15 UNFACED BATT INSULATION - MINERAL WOOL 09 29 00.L3 RC-3 RESILIENT CHANNEL – ‘WHISPERCLIP’WITH HAT CHANNEL 06 16 00.D17 7/16" ZIP SYSTEM 4"ONE HOUR FLOOR/CEILING ASSEMBLY: INTERTEK WNR FCA 60-03. STC 54 PER TJ-4035, ASSEMBLY B, TYP. FLOORS 2 & 3 1'-4" 12 6 07 31 00.A1 ASPHALT SHINGLES 07 31 00.B2 ‘ICE AND WATER’UNDERLAYMENT 07 31 00.C1 METAL DRIP EDGE 06 16 00.D8 5/8" PLYWOOD 07 62 00.H6 5" OGEE (K-STYLE) GUTTER 07 46 23.C4 FIBER CEMENT SOFFIT PANEL - PERFORATED 07 46 00.B9 WOOD COMPOSITE TRIM –5/4x8 07 21 00.D1 DENSE-PACK SPRAY-APPLIED CELLULOSE INSULATION1' - 4"07 46 23.C2 FIBER CEMENT PANEL SIDING 07 31 00.C1 METAL DRIP EDGE 07 48 00.A5 1X3 FURRING STRIPS 1'-4" 07 31 00.B2 ‘ICE AND WATER’UNDERLAYMENT 07 46 00.B8 WOOD COMPOSITE TRIM –5/4x6 06 16 00.D17 7/16" ZIP SYSTEM 1'-8" 07 46 23.C2 FIBER CEMENT PANEL SIDING 07 46 00.B1 WOOD COMPOSITE TRIM –1x4 1' - 8"09 24 00.B3 MODIFIED VENEER STUCCO 1" E2 E1 P3 07 46 23.C2 FIBER CEMENT PANEL SIDING ONE HOUR FLOOR/CEILING ASSEMBLY: INTERTEK WNR FCA 60-03. STC 54 PER TJ-4035, ASSEMBLY B, TYP. FLOORS 2 & 3 DOUBLE TOP PLATE GWB Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD 1 1/2" = 1'-0"6/22/2020 10:10:38 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA501 DETAILS 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 1 1/2" = 1'-0"C1 SECOND AND THIRD FLOOR FRAMING 1 1/2" = 1'-0"A1 EAVE 1 1/2" = 1'-0"D2 ROOF-RAKE DETAIL 1 1/2" = 1'-0"B1 EXTERIOR CORNER AT FIBER CEMENT BOARD & BATTEN (PLAN) 1 1/2" = 1'-0"D1 EXTERIOR CORNER AT STUCCO 1 1/2" = 1'-0"C2 DEMISE WALL TRANSITION (PLAN) 1 1/2" = 1'-0"B2 P3 TO E1 TRANSITION 1 1/2" = 1'-0"B3 DOUBLE TOP PLATE FRAMING (TYPICAL AT ALL INTERIOR WALLS) REVISIONS Δ DESCRIPTION DATE REFERENCE KEYNOTES KEY NOTE 03 31 00.J5 4" CAST-IN-PLACE CONCRETE SLAB WITH 6x6 W2.9 x W2.9 05 05 23.E3 5/8" HOOKED ANCHOR BOLT 06 11 00.D1 2x4 06 11 00.E1 2x6 06 11 00.G1 2x8 06 11 00.H1 2x10 06 16 00.D8 5/8" PLYWOOD 06 16 00.D17 7/16" ZIP SYSTEM 06 16 00.H2 1/2” MAGNESIUM OXIDE PANEL 06 22 00.A2 1x2 WOOD TRIM 06 46 00.B2 3/4" x 3/4" COVE MOLDING 06 46 00.E1 3/4" x 1 3/8" BASE CAP MOLDING 07 21 00.A3 R-15 UNFACED BATT INSULATION - MINERAL WOOL 07 21 00.A6 R-23 UNFACED BATT INSULATION - MINERAL WOOL 07 21 00.A8 R-30 UNFACED BATT INSULATION - MINERAL WOOL 07 21 00.B6 3" XPS RIGID INSULATION 07 21 00.D1 DENSE-PACK SPRAY-APPLIED CELLULOSE INSULATION 07 24 00.A1 EIFS ON INSULATION BOARD 07 26 00.A5 CLASS III VAPOR RETARDER 07 27 00.A1 SILL SEALER 07 31 00.A1 ASPHALT SHINGLES 07 31 00.B2 ‘ICE AND WATER’ UNDERLAYMENT 07 31 00.C1 METAL DRIP EDGE 07 46 00.B1 WOOD COMPOSITE TRIM – 1x4 07 46 00.B8 WOOD COMPOSITE TRIM – 5/4x6 07 46 00.B9 WOOD COMPOSITE TRIM – 5/4x8 07 46 23.C2 FIBER CEMENT PANEL SIDING 07 46 23.C4 FIBER CEMENT SOFFIT PANEL - PERFORATED 07 46 23.D1 BOARD AND BATTEN SIDING 07 48 00.A5 1X3 FURRING STRIPS 07 48 00.B1 COR A VENT SV-5 07 62 00.A2 ALUMINUM FLASHING 07 62 00.H6 5" OGEE (K-STYLE) GUTTER 07 65 00.A3 SELF-ADHERED FLASHING 07 84 00.A1 2X FIRE STOPPING 07 92 00.A1 SEALANT – TYPE 1 (SILICONE, EXTERIOR) 07 92 00.A5 SEALANT – TYPE 5 (LATEX, INTERIOR) 07 92 00.A6 SEALANT – TYPE 6 (LATEX, ACOUSTICAL, FIRE RATED) 07 92 00.B2 BACKER ROD AND SEALANT 09 24 00.B3 MODIFIED VENEER STUCCO 09 29 00.A2 3/8" GYPSUM WALLBOARD 09 29 00.D1 5/8" GYPSUM WALLBOARD 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD 09 29 00.D12 2 LAYERS 5/8" TYPE "X" GYPSUM BOARD 09 29 00.L1 RC-1 RESILIENT CHANNEL – SINGLE LEG 09 29 00.L3 RC-3 RESILIENT CHANNEL – ‘WHISPERCLIP’ WITH HAT CHANNEL 09 29 00.M1 CEMENTITIOUS BACKER BOARD 09 65 00.A1 RESILIENT FLOORING 31 05 19.A1 FILTER MAT 31 23 00.B1 GRAVEL 31 23 00.B2 COMPACTED GRAVEL SUB-BASE 33 46 00.A3 6" PERFORATED PVC PIPE GENERAL SHEET NOTES - DETAILS 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 All 2x8 framing, 16" O.C. 3 See detail D1 for wall type P4 82 41 828241 8231 41828 282828282 82 82 82 82 82 823141 4107 46 23.C2 FIBER CEMENT PANEL SIDING 06 22 00.A2 1x2 WOOD TRIM 07 92 00.A1 SEALANT –TYPE 1 (SILICONE, EXTERIOR) 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARDBY WINDOW MFR 07 92 00.A5 SEALANT –TYPE 5 (LATEX, INTERIOR) 07 92 00.B2 BACKER ROD AND SEALANT 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD 06 16 00.D17 7/16" ZIP SYSTEM07 65 00.A3 SELF-ADHERED FLASHING 07 46 23.C2 FIBER CEMENT PANEL SIDING5/16" 07 92 00.B2 BACKER ROD AND SEALANT 07 92 00.A5 SEALANT –TYPE 5 (LATEX, INTERIOR) 07 48 00.B1 COR A VENT SV-5 06 16 00.D17 7/16" ZIP SYSTEM 07 65 00.A3 SELF-ADHERED FLASHING 07 65 00.A3 SELF-ADHERED FLASHING SIDING VARIES TRIM BY WINDOW MFR 07 46 23.C2 FIBER CEMENT PANEL SIDING 06 22 00.A2 1x2 WOOD TRIM 07 92 00.A1 SEALANT –TYPE 1 (SILICONE, EXTERIOR) 07 92 00.B2 BACKER ROD AND SEALANT 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD BY WINDOW MFR 07 92 00.A5 SEALANT –TYPE 5 (LATEX, INTERIOR) 07 92 00.B2 BACKER ROD AND SEALANT 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD 06 16 00.D17 7/16" ZIP SYSTEM 07 65 00.A3 SELF-ADHERED FLASHING SIDING TYPE VARIES 07 92 00.A5 SEALANT –TYPE 5 (LATEX, INTERIOR) 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD 06 16 00.D17 7/16" ZIP SYSTEM 07 65 00.A3 SELF-ADHERED FLASHING STEEL BRACKET PLATE ABOVE SHUTTER 07 92 00.B2 BACKER ROD AND SEALANT 07 92 00.A5 SEALANT –TYPE 5 (LATEX, INTERIOR) 07 48 00.B1 COR A VENT SV-5 06 16 00.D17 7/16" ZIP SYSTEM 07 65 00.A3 SELF-ADHERED FLASHING 2X BLOCKING, THRU-BOLT CLEVIS PER MANUF. INSTRUCTIONS MANUF. ALUMINUM CANOPY,SEE SPEC. THRU-BOLT CANOPY INTO RIM JOIST PER MANUF. INSTRUCTIONS 1X8 COMPOSITE TRIM 07 92 00.A5 SEALANT –TYPE 5 (LATEX, INTERIOR) 07 65 00.A3 SELF-ADHERED FLASHING 07 62 00.A2 ALUMINUM FLASHING FUSELINKS ON BOTH SIDES OF OPENING STEEL ANGLE FLASHING SIDING Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD As indicated6/22/2020 10:10:40 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA502 WINDOW DETAILS 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET 3" = 1'-0"B2 WINDOW SILL- FIBER CEMENT & BATTEN 3" = 1'-0"D1 WINDOW JAMB-FIBER CEMENT & BATTEN 3" = 1'-0"D2 WINDOW HEAD (TYP., EXCEPT AT FIRE SHUTTERS) 3" = 1'-0"B1 WINDOW SILL- STUCCO 3" = 1'-0"C1 WINDOW JAMB 3" = 1'-0"C2 WINDOW JAMB AT FIRE SHUTTER 3" = 1'-0"A1 WINDOW HEAD REFERENCE KEYNOTES KEY NOTE 03 31 00.J5 4" CAST-IN-PLACE CONCRETE SLAB WITH 6x6 W2.9 x W2.9 05 05 23.E3 5/8" HOOKED ANCHOR BOLT 06 11 00.D1 2x4 06 11 00.E1 2x6 06 11 00.G1 2x8 06 11 00.H1 2x10 06 16 00.D8 5/8" PLYWOOD 06 16 00.D17 7/16" ZIP SYSTEM 06 16 00.H2 1/2” MAGNESIUM OXIDE PANEL 06 22 00.A2 1x2 WOOD TRIM 06 46 00.B2 3/4" x 3/4" COVE MOLDING 06 46 00.E1 3/4" x 1 3/8" BASE CAP MOLDING 07 21 00.A3 R-15 UNFACED BATT INSULATION - MINERAL WOOL 07 21 00.A6 R-23 UNFACED BATT INSULATION - MINERAL WOOL 07 21 00.A8 R-30 UNFACED BATT INSULATION - MINERAL WOOL 07 21 00.B6 3" XPS RIGID INSULATION 07 21 00.D1 DENSE-PACK SPRAY-APPLIED CELLULOSE INSULATION 07 24 00.A1 EIFS ON INSULATION BOARD 07 26 00.A5 CLASS III VAPOR RETARDER 07 27 00.A1 SILL SEALER 07 31 00.A1 ASPHALT SHINGLES 07 31 00.B2 ‘ICE AND WATER’ UNDERLAYMENT 07 31 00.C1 METAL DRIP EDGE 07 46 00.B1 WOOD COMPOSITE TRIM – 1x4 07 46 00.B8 WOOD COMPOSITE TRIM – 5/4x6 07 46 00.B9 WOOD COMPOSITE TRIM – 5/4x8 07 46 23.C2 FIBER CEMENT PANEL SIDING 07 46 23.C4 FIBER CEMENT SOFFIT PANEL - PERFORATED 07 46 23.D1 BOARD AND BATTEN SIDING 07 48 00.A5 1X3 FURRING STRIPS 07 48 00.B1 COR A VENT SV-5 07 62 00.A2 ALUMINUM FLASHING 07 62 00.H6 5" OGEE (K-STYLE) GUTTER 07 65 00.A3 SELF-ADHERED FLASHING 07 84 00.A1 2X FIRE STOPPING 07 92 00.A1 SEALANT – TYPE 1 (SILICONE, EXTERIOR) 07 92 00.A5 SEALANT – TYPE 5 (LATEX, INTERIOR) 07 92 00.A6 SEALANT – TYPE 6 (LATEX, ACOUSTICAL, FIRE RATED) 07 92 00.B2 BACKER ROD AND SEALANT 09 24 00.B3 MODIFIED VENEER STUCCO 09 29 00.A2 3/8" GYPSUM WALLBOARD 09 29 00.D1 5/8" GYPSUM WALLBOARD 09 29 00.D11 5/8" TYPE "X" GYPSUM WALLBOARD 09 29 00.D12 2 LAYERS 5/8" TYPE "X" GYPSUM BOARD 09 29 00.L1 RC-1 RESILIENT CHANNEL – SINGLE LEG 09 29 00.L3 RC-3 RESILIENT CHANNEL – ‘WHISPERCLIP’ WITH HAT CHANNEL 09 29 00.M1 CEMENTITIOUS BACKER BOARD 09 65 00.A1 RESILIENT FLOORING 31 05 19.A1 FILTER MAT 31 23 00.B1 GRAVEL 31 23 00.B2 COMPACTED GRAVEL SUB-BASE 33 46 00.A3 6" PERFORATED PVC PIPE GENERAL SHEET NOTES - DETAILS 1 Refer to Specifications, DIVISION 01, for additional information and requirements. 2 All 2x8 framing, 16" O.C. 3 See detail D1 for wall type P4 1 1/2" = 1'-0"B3 CANOPY DETAIL 3" = 1'-0"D3 WINDOW - FIRE SHUTTER NOTE: -PROVIDE ANDERSON 400 SERIES WINDOWS ON N, E, AND W ELEVATIONS -PROVIDE ANDERSEN 100 SERIES ON S ELEVATION REVISIONS Δ DESCRIPTION DATE Project # Date STREAM Collaborative architecture + landscape architecture dpc 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com A 1 2 3 4 BCD6/22/2020 10:10:42 AMC:\Users\Jacob Marnell\Documents\2018015 - 327 W.Seneca Street_jacobS4ZDL.rvtA601 SCHEDULES 2018015327 W. SENECA STREET06/10/2019VISUM DEVELOPMENTCITY OF ITHACA, NYCONSTRUCTION SET VENTILATION - REQUIRED MARK ROOM NAME AREA 4% VENT 1ST SUB FLOOR A101 LIVING/ DINING 141 SF 6 SF A102 KITCHEN 56 SF 2 SF A103 SLEEPING 116 SF 5 SF A101 13 SF B101 LIVING/ DINING 247 SF 10 SF B102 KITCHEN 100 SF 4 SF B101 14 SF B106 BEDROOM 1 113 SF 5 SF B106 5 SF B107 BEDROOM 2 113 SF 5 SF B107 5 SF C101 LIVING/ DINING 247 SF 10 SF C102 KITCHEN 100 SF 4 SF C101 14 SF C106 BEDROOM 1 113 SF 5 SF C106 5 SF C107 BEDROOM 2 113 SF 5 SF C107 5 SF D101 LIVING/ DINING 161 SF 6 SF D102 KITCHEN 37 SF 1 SF D103 SLEEPING 117 SF 5 SF D101 13 SF 2ND FLOOR SUB FLOOR A205 LIVING/ SLEEPING 324 SF 13 SF A205 13 SF B201 LIVING/ DINING 294 SF 12 SF B202 KITCHEN 67 SF 3 SF B201 14 SF B205 BEDROOM 1 113 SF 5 SF B205 5 SF B206 BEDROOM 2 113 SF 5 SF B206 5 SF C201 LIVING/ DINING 293 SF 12 SF C202 KITCHEN 68 SF 3 SF C201 14 SF C205 BEDROOM 1 113 SF 5 SF C205 5 SF C206 BEDROOM 2 113 SF 5 SF C206 5 SF D201 KITCHEN 328 SF 13 SF D205 13 SF 3RD FLOOR SUB FLOOR A305 LIVING/ SLEEPING 324 SF 13 SF A305 13 SF B301 LIVING/ DINING 296 SF 12 SF B302 KITCHEN 68 SF 3 SF B301 15 SF B305 BEDROOM 1 113 SF 5 SF B305 5 SF B306 BEDROOM 2 113 SF 5 SF B306 5 SF C301 LIVING/ DINING 295 SF 12 SF C302 KITCHEN 68 SF 3 SF C301 15 SF C305 BEDROOM 1 113 SF 5 SF C305 5 SF C306 BEDROOM 2 113 SF 5 SF C306 5 SF D301 KITCHEN 328 SF 13 SF D305 13 SF VENTILATION - ACTUAL MARK ROOM NAME VENT 1ST SUB FLOOR A101 LIVING/ DINING 7 SF B101 LIVING/ DINING 14 SF B106 BEDROOM 1 7 SF B107 BEDROOM 2 7 SF C101 LIVING/ DINING 14 SF C106 BEDROOM 1 7 SF C107 BEDROOM 2 7 SF D101 LIVING/ DINING 20 SF 2ND FLOOR SUB FLOOR A205 LIVING/ SLEEPING 20 SF B201 LIVING/ DINING 20 SF B205 BEDROOM 1 7 SF B206 BEDROOM 2 14 SF C201 LIVING/ DINING 20 SF C205 BEDROOM 1 7 SF C206 BEDROOM 2 7 SF D201 KITCHEN 27 SF 3RD FLOOR SUB FLOOR A305 LIVING/ SLEEPING 20 SF B301 LIVING/ DINING 20 SF B305 BEDROOM 1 7 SF B306 BEDROOM 2 14 SF C301 LIVING/ DINING 20 SF C305 BEDROOM 1 7 SF C306 BEDROOM 2 7 SF D301 KITCHEN 27 SF WINDOW SCHEDULE MARK OPERATION UNIT WIDTH UNIT HEIGHT SILL HEIGHT HEAD HEIGHT GLAZING SAFETY WOCD EGRESS COMMENTS HEADER 1ST SUB FLOOR A101A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes SAFETY GLASS (2) 2x (?) TYPICAL A101B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes B101A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes B101B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes B106 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes B107 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes C101A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes C101B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes C106 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes C107 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes D101A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes D101B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes D101C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes 2ND FLOOR SUB FLOOR 200 FIXED 2' - 0" 3' - 0" 0" 3' - 0" TYPE "B" SMARTSUN Yes SAFETY GLASS (2) 2x (?) TYPICAL 201 FIXED 2' - 0" 3' - 0" 4' - 0" 7' - 0" TYPE "B" SMARTSUN Yes SAFETY GLASS A203 FIXED 2' - 0" 3' - 0" 4' - 0" 7' - 0" TYPE "B" SMARTSUN Yes SAFETY GLASS, PATTERNED A205A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes A205B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes A205C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes B201A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes B201B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes B201C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes B205 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes B206A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes B206B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes C201A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes C201B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes C201C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes C205 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes C206 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes D203 FIXED 2' - 0" 3' - 0" 4' - 0" 7' - 0" TYPE "B" SMARTSUN Yes SAFETY GLASS, PATTERNED D205A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes D205B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes D205C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes D205D SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes 3RD FLOOR SUB FLOOR 300 FIXED 2' - 0" 3' - 0" 0" 3' - 0" TYPE "B" SMARTSUN Yes SAFETY GLASS (2) 2x (?) TYPICAL 301 FIXED 2' - 0" 3' - 0" 4' - 0" 7' - 0" TYPE "B" SMARTSUN Yes SAFETY GLASS A302 FIXED 2' - 0" 3' - 0" 4' - 0" 7' - 0" TYPE "B" SMARTSUN Yes SAFETY GLASS, PATTERNED A305A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes A305B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes A305C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes B301A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes B301B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes B301C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes B305 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes B306A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes B306B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes C301A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes C301B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes C301C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "A" LOW-E Yes Yes C305 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes C306 SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes D302 FIXED 2' - 0" 3' - 0" 4' - 0" 7' - 0" TYPE "B" SMARTSUN Yes SAFETY GLASS, PATTERNED D305A SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes D305B SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes D305C SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes D305D SINGLE HUNG 3' - 0" 5' - 0" 2' - 0" 7' - 0" TYPE "B" SMARTSUN Yes Yes DOOR SCHEDULE MARK ROOM NAME WIDTH HEIGHT DESCRIPTION FRAME MATERIAL DOOR MATERIAL FIRE RATING HARDWARE SET 1ST SUB FLOOR 100 STAIR ENTRY 3' - 0" 7' - 0" 1-LITE ALUM FRP 1 102 MECH. 3' - 0" 7' - 0" FLUSH ALUM FRP 8 A100 KITCHEN 3' - 0" 7' - 0" 1-LITE HM FRP 2 A104 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 A105 BATH 3' - 0" 6' - 8" 2-PANEL WD MASONITE 5 B100 LIVING/ DINING 3' - 0" 7' - 0" 2-PANEL ALUM FRP 45 MIN 2 B103 BATH 3' - 0" 6' - 8" 2-PANEL WD MASONITE 5 B104 MECH. 2' - 2" 6' - 8" 2-PANEL WD MASONITE 7 B105 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 B106 BEDROOM 1 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4 B107 BEDROOM 2 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4 B108 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 C100 LIVING/ DINING 3' - 0" 7' - 0" 2-PANEL ALUM FRP 45 MIN 2 C103 BATH 3' - 0" 6' - 8" 2-PANEL WD MASONITE 5 C104 MECH. 2' - 2" 6' - 8" 2-PANEL WD MASONITE 7 C105 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 C106 BEDROOM 1 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4 C107 BEDROOM 2 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4 C108 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 D100 LIVING/ DINING 3' - 0" 7' - 0" 1-LITE ALUM FRP 1 D104 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 D105 BATH 3' - 0" 6' - 8" 2-PANEL WD MASONITE 5 2ND FLOOR SUB FLOOR A200 LIVING/ SLEEPING 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3 A202 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5 A203 MECH/ LDRY 5' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 A204 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 B200 LIVING/ DINING 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3 B203 CLO. 6' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 B204 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 B205 BEDROOM 1 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4 B206 BEDROOM 2 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4 B207 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 B208 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5 C200 LIVING/ DINING 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3 C203 CLO. 6' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 C204 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 C205 BEDROOM 1 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4 C206 BEDROOM 2 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4 C207 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 C208 LIVING/ DINING 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5 D200 KITCHEN 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3 D202 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5 D203 KITCHEN 5' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 D204 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 3RD FLOOR SUB FLOOR A300 LIVING/ SLEEPING 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3 A302 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5 A303 LIVING/ SLEEPING 5' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 A304 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 B300 LIVING/ DINING 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3 B303 LIVING/ DINING 6' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 B304 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 B305 LIVING/ DINING 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4 B306 BEDROOM 2 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4 B307 BEDROOM 2 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 B308 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5 C300 LIVING/ DINING 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3 C303 CLO. 6' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 C304 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 C305 BEDROOM 1 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4 C306 BEDROOM 2 2' - 6" 6' - 8" 2-PANEL WD MASONITE 4 C307 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 C308 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5 D300 KITCHEN 3' - 0" 6' - 8" 2-PANEL HM HM 45 MIN 3 D302 BATH 2' - 6" 6' - 8" 2-PANEL WD MASONITE 5 D303 CLO. 4' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 D304 MECH./ LDRY 5' - 0" 6' - 8" 2-PANEL PAIR WD MASONITE 7 ROOM FINISH SCHEDULE ROOM NUMBER ROOM NAME FLOOR FINISH BASE FINISH WALL FINISH CEIING FINISH COMMENTS 100 STAIR ENTRY RESILIENT RESILIENT PAINT PAINT 1, 4 101 STAIR RESILIENT RESILIENT PAINT PAINT 1, 4 102 MECH. FIN. CONCRETE RESILIENT PAINT PAINT 4 BEDS BEDROOMS CARPET TILE RESILIENT PAINT PAINT 3, 4 VARIES ALL, U.N.O RESILIENT RESILIENT PAINT PAINT 2, 4 1.PROVIDE RESILIENT THERMOSET FLOOR/BASE PRODUCTS, PER SPEC ______ 2.RESILIENT FLOORING AND BASE TO BE SELECTED BY OWNER. 3.CARPET TILE TO BE SELECTED BY OWNER. 4.PAINT COLOR TO BE SELECTED BY OWNER. REFER TO SPEC. SECTION 09 9100 FOR SHEEN AND NUMBER OF COATS. REVISIONS Δ DESCRIPTION DATE