HomeMy WebLinkAboutOlin Hall DrawingsDRAWING LISTGENERALG-000Cover Sheet G-001Code Compliance Drawings and Fire Safety PlansHAZARDOUS MATERIALSHM-101Fifth Floor Hazardous Materials Abatement PlanARCHITECTURAL A-000General Notes & LegendsA-101Fifth Floor Demolition PlanA-110Fifth Floor PlanA-130Fifth Floor Reflected Ceiling PlanA-420Interior ElevationsA-501Casework DetailsA-601Door Schedule & DetailsA-602Room Finish Schedule & LegendMECHANICALM-000HVAC Symbols, Notes & AbbreviationsM-101HVAC DemolitionM-102HVAC New WorkM-500HVAC DetailsM-501HVAC DetailsM-600HVAC SchedulesMI-000BMS Controls Legend and NotesMI-600Controls Schematic Lab 580AMI-601Controls Points List Lab 580AMI-602Controls Schematic Lab 573MI-603Controls Schematic & Lab 573 Points ListFIRE PROTECTIONFP-000Fire Protection Symbols, Notes & AbbreviationsFP-101Overall Fifth Floor Plan -Fire ProtectionFP-500Fire Protection DetailsPLUMBINGP-000Plumbing Symbols, Notes & AbbreviationsP-101Plumbing DemolitionP-102Plumbing New WorkELECTRICALE-000Electrical Symbols, Notes & AbbreviationsE-500Electrical Details & SchedulesED-101 Fifth Floor Plan -Demo LightingED-102Fifth Floor Plan -Demo Power & TelecomEL-101Fifth Floor Plan -LightingEP-101Fifth Floor Plan -PowerET-101Fifth Floor Plan -TelecomFA-001Key Plans - Fire Alarm These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:RevisionsSWBR Project #5/20/2020 10:19:31 AMC:\1-Local Revit Models 2019\19700.00_Cornell Olin Chem Lab 573-580_Arch_R19_central_walkup54.rvt19700.00SDFCover SheetCWJCREG-000100% ConstructionDocumentsCornell UniversityS.T. Olin Chemistry ResearchWing -Chem Lab 573-580RenovationFacilities & Campus Services -Humphreys Service Building,Ithaca, NY 1485305/22/202005/22/2020S.T. Olin ChemistryResearch Wing -ChemLab 573-580 Renovation100% Construction Documents19700.00259 East AvenueIthaca, NY 14850Aerial PhotoLocation MapARCHITECT & STRUCTURAL ENGINEER:SWBR387 EAST MAIN STREETROCHESTER, NY 14604585 232 8300ROCHESTER@SWBR.COMMECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION ENGINEERERDMAN ANTHONY145 CULVER ROAD, SUITE 200ROCHESTER, NY 14620585 427 8888 ENVIRONMENTAL ENGINEERARCTIC ENTERPRISES, INC222 TEAL AVENUE, SUITE 201SYRACUSE, NY 13210315 476 1757 S.T. Olin Chemistry Research WingS.T. Olin Chemistry Research WingFA-101Fifth Floor Plan -Fire Alarm E2E2E2E2E2E2E2E2E2E2E2E1E1E1E1E1E1E1E1E1E1E2E2E2E2E2E2E2E2E2E2E2E2E2E2E2E2E2E2E2E2E2222222E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E2E2E2E2E2E1E1E2E2E1E1E1FPE1FP111FP1FPE2E2E2E2E2E2E1E1E1E1E1E1E1E1E1E1E1E1E2E2E2E1E2E2E2E1E1E1E1E1E1E1E1E2E2E2E12222E2E2E2E1E1E2E2E2E2E2E2E1E1E1E1E2E222E2E2E2E2E2E2E2E2E2E2E2E2E2E2E2E2E2E2281 SFOFFICE560A515 SFLAB580A218 SFWRITE-UP580277 SFP.I. OFFICE582ASTAIR500SB63 SFMECH500UD342 SFLAB573712 SFLAB575127 SFOFFICE582220 SFWRITE-UP562A515 SFLAB562MENS'500TAELEVATOR500EA65 SFMECH500UASTAIR500SA573 SFLAB570116 SFWRITE-UP570A119 SFWRITE-UP572A408 SFCONFERENCE561119 SFOFFICE560205 SFWRITE-UP563779 SFLAB565487 SFMECH500UE86 SFMECH500UBELEVATOR500EB60 SFMECH500UCWOMEN'S500TB17 SF550J34 SF569CORRIDOR500CACORRIDOR500CAEADA HTHATCH INDICATES PROJECT WORK AREA (ALTERATION -LEVEL 2)HATCH INDICATES PROJECT WORK AREA (ALTERATION -LEVEL 2)CPOE = 64' -1"CPOE = 33' -0"EATD = 52' -9"ACCESSIBLE PATHDOOR COMPLIES WITH PUSH SIDE CLEARANCE FOR EXITING573 SFLAB572358 SFLAB571NOTE: AREAS OF WORK NOT INITIALLY INTENDED BY THE OWNER REQUIRED FOR CODE COMPLIANCE ARE EXCLUDED FROM THE WORK AREA (EBC SECTION 202)SIM. UL U906 & U914CODE COMPLIANCE PLAN GENERAL NOTESTHE FOLLOWING BUILDING AND ACCESSIBILITY CODES AND STANDARDS ARE APPLICABLE TO THIS PROJECT:1.A.B.C.D.E.F. G.H.I.J.2020 BUILDING CODE OF NEW YORK STATE2020 EXISTING BUILDING CODE OF NEW YORK STATE2020 FIRE CODE OF NEW YORK STATE2020 PLUMBING CODE OF NEW YORK STATE2020 MECHANICAL CODE OF NEW YORK STATE2020 FUEL GAS CODE OF NEW YORK STATE2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATENATIONAL ELECTRICAL CODE, NFPA 70, -2017 EDITION AS REFERENCED BY THE NYS CODES ABOVE.ICC/ANSI A117.1, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES -2009 EDITION AS REFERENCED BY THE NYS CODES ABOVE.U.S. DEPARTMENT OF JUSTICE, 2010 AMERICANS WITH DISABILITIES ACT (ADA) STANDARDS FOR ACCESSIBLE DESIGN.CODE COMPLIANCE DRAWINGS ARE INTENDED TO ASSIST IN THE PERMIT PROCESS AND TO PROVIDE GENERAL INFORMATION TO THE CONTRACTORS WITH RESPECT TO LIFE-SAFETY PROVISIONS OF THE PROJECT. THESE DRAWINGS SHOULD NOT BE USED TO DETERMINE THE SCOPE OF OTHER WORK SPECIFICALLY INDICATED ELSEWHERE IN THE DOCUMENTS. THESE DRAWINGS SHALL BE USED FOR THE LOCATIONS OF FIRE-RESISTANT RATED WALL CONSTRUCTION.3.REFERENCE FCNYS CHAPTER 33 FOR FIRE SAFETY PROVISIONS DURING CONSTRUCTION, DEMOLITION.4.5.WHEN THE PREFIX "E" IS INDICATED ON THE CODE COMPLIANCE FLOOR PLAN, IT DENOTES EXISTING WALL CONSTRUCTION WITH A PRESUMED FIRE-RESISTANCE RATING OF THE TYPE INDICATED. THE ACTUAL CONDITIONS IN THE FIELD HAVE NOT BEEN VERIFIED TO CONFIRM COMPLIANCE. NEW PENETRATIONS REQUIRE FIRESTOP SYSTEMS FOR THE HOURLY RATING INDICATED.PENETRATIONS THROUGH FIRE-RESISTANT CONSTRUCTION SHALL BE BUILT IN ACCORDANCE WITH U.L. LISTED THROUGH-PENETRATION FIRESTOP SYSTEMS. SEE CODE COMPLIANCE PLAN FOR FIRE-RATED PARTITION LOCATIONS.THE OWNER WILL APPLY THE PROVISIONS OF SECTION 428 OF THE 2020 BUILDING CODE OF NEW YORK STATE FOR MANAGEMENT OF CHEMICAL QUANTITIES. "LAB SUITES" ARE DEFINED IN THAT SECTION. SEPARATIONS PROVIDED IN THIS PROJECT COMPLY WITH PROVISIONS OF CHEMICAL CONTROL AREAS AS DEFINED BY 414.2 OF THE 2020 BCNYS AS WELL AS REQUIREMENTS OF SECTION 428 OF THE 2020 BCNYS.2.FIRE RESISTANCE RATING SCHEDULE FOR BUILDING ELEMENTSCONSTRUCTION CLASSIFICATION TYPE IA . ADDITIONAL FIRE-RESISTANCE REQUIREMENTS THROUGHOUT THE BUILDING ARE BASED ON OCCUPANCY. REFER TO CODE COMPLIANCE PLANS AND G-SERIES DRAWINGS FOR MORE INFORMATION.DESCRIPTIONTEST REFERENCECOMMENTSFIRE RESISTANCEREQUIRED RATING / HR STRUCTURAL FRAME INCLUDING COLUMNS, GIRDERS AND BEAMS3BEARING WALLS:3FLOOR CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOISTS2ROOF CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOISTS1 1/23NOTE: THIS TABLE INDICATES MINIMUM BUILDING FIRE RESISTANCE REQUIREMENTS BASED ON CONSTRUCTION CLASSIFICATION AND IN ACCORDANCE WITH NYSBC TABLE 601. NON-BEARING WALLS & PARTITIONS:00FIRE RESISTANCEPROVIDED RATING / HR EXISTING0INTERIOR EXISTING ASSEMBLY; POURED CONCRETE FLOOR SLAB EXISTING ASSEMBLYEXTERIORINTERIOREXTERIOR EXISTING ASSEMBLY; MASONRY CAVITY WALLEXISTINGN/AN/AN/AEXISTINGEXISTING ASSEMBLY; PROTECTED STRUCTURAL STEEL EXISTINGN/AEXISTINGEXISTINGEXISTINGEXISTINGLIFE SAFETY LEGEND: COMMON PATH OF EGRESS TRAVEL (NOT TO EXCEED 100 FEET) EGRESS ACCESS TRAVEL DISTANCE (NOT TO EXCEED 300 FEET)CPOE = X'-X"EATD = X'-X"EEXIT. MAINTAIN OPERATIONAL AT ALL TIMES DURING CONSTRUCTION.STORAGEROOM NAMEACCESSIBLE ELEMENTPER ICC/ANSI A117.1-2003EXISTING 2-HOUR RATED FIRE BARRIEREXISTING 1-HOUR RATED FIRE BARRIEREXISTING 1-HOUR RATED FIRE PARTITION1-HOUR RATED FIRE BARRIER1-HOUR RATED FIRE PARTITIONNOTE:AT EXISTING FIRE BARRIERS/PARTITIONS, REFER TO 'A' SERIES DRAWINGS FOR WORK REQUIRED TO MAKE COMPLIANT. CONTRACTOR SHALL VERIFY IN FIELD THE CONTINUITY OF EXISTING RATED ASSEMBLIES FOLLOWING SELECTIVE DEMOLITION. BUILDING DATA AND CODE COMPLIANCECLASSIFICATIONS OF BUILDING, AS SPECIFIED IN THE 2020 EDITION OF THE BUILDING CODE OF NEW YORK STATE ARE AS FOLLOWS:BUILDING DATA:CONSTRUCTION CLASSIFICATION:IA (ASSUMED BASED ON 2003 ALTERATION DRAWINGS)BUILDING OCCUPANCY CLASSIFICATION:B [BUSINESS] FIRE PROTECTION SYSTEM:PARTIALLY SPRINKLERED, 5TH FLOOR WILL BE FULLY SPRINKLEREDLEVEL 2 ALTERATION AREA:1,520 SFEXISTING FLOOR ASSEMBLY:2 HR FIRE-RATEDALTERATION CLASSIFICATIONS OF WORK, AS SPECIFIED IN THE 2020 EDITION OF THE BUILDING CODE OF THE NEW YORK STATE ARE AS FOLLOWS:ALTERATION -LEVEL 2LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF DOORS AND WINDOWS, THE RECONFIGURATION OR THE EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL SYSTEM. LEVEL 2 ALTERATIONS SHALL ALSO COMPLY WITH THE REQUIREMENTS OF A LEVEL 1 ALTERATIONS.LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OR THE COVERING OF EXISTING MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES USING NEW MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES THAT SERVE THE SAME PURPOSE. 281 SFOFFICE560A515 SFLAB580A218 SFWRITE-UP580277 SFP.I. OFFICE582ASTAIR500SB63 SFMECH500UD342 SFLAB573712 SFLAB575127 SFOFFICE582220 SFWRITE-UP562A515 SFLAB562MENS'500TAELEVATOR500EA65 SFMECH500UASTAIR500SA573 SFLAB570116 SFWRITE-UP570A119 SFWRITE-UP572A573 SFLAB572408 SFCONFERENCE561119 SFOFFICE560205 SFWRITE-UP563779 SFLAB565487 SFMECH500UE358 SFLAB57186 SFMECH500UBELEVATOR500EB60 SFMECH500UCWOMEN'S500TB17 SFRoom550J34 SFRoom569CORRIDOR500CALAB SUITE ALAB SUITE B LAB SUITE ALAB SUITE B These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions5/20/2020 10:19:36 AMC:\1-Local Revit Models 2019\19700.00_Cornell Olin Chem Lab 573-580_Arch_R19_central_walkup54.rvt19700.00SDFCode ComplianceDrawings and FireSafety PlansCWJCREG-001100% ConstructionDocumentsCornell UniversityS.T. Olin Chemistry ResearchWing -Chem Lab 573-580RenovationFacilities & Campus Services -Humphreys Service Building,Ithaca, NY 1485305/22/2020NORTH1/8" = 1'-0"15th Floor Code Compliance Plan1/16" = 1'-0"25th Floor Code Compliance Plan FEFEFE 12345678910111213 A B C D E These documents and all the ideas, arrangements,designs and plans indicated thereon or presentedthereby are owned by and remain the property ofSWBR and no part thereof shall be utilized by anyperson, firm, or corporation for any purposewhatsoever except with the specific writtenpermission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com SWBR Project Number Checked By: Project Manager: Drawn By: Revisions10/29/2019 4:44:32 PMC:\1-Local Revit Models 2019\19700.00_Cornell Olin Chem Lab 573-580_Arch_R19_central_kristins.rvt19700.00 BR CWJ BR HM-101 )LIWK)ORRU+D]DUGRXV 0DWHULDOV$EDWHPHQW 3ODQ Cornell University S.T. Olin Chemistry Research Wing - Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building,Ithaca, NY 14853 5/22/2020 ABATE ACM TRANSITE FUME HOODS, ASSOCIATED COUNTERTOPS AND SINKS. COORDINATE ALL DISCONNECTS WITH OWNER AND OTHER TRADES (285 SF). ABATE FLOOR TILE MASTIC AND ASSOCIATED NON-ACM FLOOR TILE - MAY EXIST UNDER COUNTERS, CABINETRY AND WALLS (1,070 SF). CONDUCT FASTENING INTO PRESUMED ACM WALL/BEAM CAVITY AS NEEDED TO SUPPORT INSTALLATION OF FIRE DOORS. WORK SHALL BE CONDUCTED IN ACCORDANCE WITH CORNELL FWSSV (10 SF). ABATE CAULK ON RADIATOR CABINETS ( @ BLOCK WALL), CAULK IS ALSO PRESUMED PCB-CONTAINING. COORDINATE W/ CORNELL EH & S FOR DISPOSAL (2 SF). REMOVE PRESUMED HAZARDOUS GLASS SINK TRAPS AND TURN OVER TO CORNELL EH & S FOR DISPOSAL (16). ABATE PRESUMED ACM DOOR PANEL (60 SF). ABATE ACM MASTIC @ INTERIOR OF RADIATOR COVERS (WHICH ARE SCHEDULED TO REMAIN). ABATEMENT CONTRACTOR TO RE-INSTALL PRIOR TO DEMOBILIZATION (46 SF). DEMOLITION OF DUCTWORK ASSOCIATED W/ FUME HOODS IN LAB 573 & 580 SHALL BE CONDUCTED BY ABATEMENT CONTRACTOR UTILIZING PPE AS A PRECAUTION IN COMPLIANCE WITH CORNELL EHS DIRECTIVE, 11/20/19. DUCTWORK SHALL BE DISPOSED OF AS C & D. COORDINATE EXTENT OF REMOVAL WITH M-101. 1 ABATEMENT KEYED NOTES: 2 3 4 5 1 2 5 5 5 5 5 5 5 1 4 4 4 4 2 5 GENERAL NOTES: 1. CONTRACTOR TO PROTECT THEIR EMPLOYEES WITH ADEQUATE PERSONAL PROTECTIVE EQUIPMENT AT ALL TIMES (REGARDLESS OF NEGATIVE EXPOSURE ASSESSMENT DATA) WHEN PERFORMING WORK ON THIS PROJECT. 2. THE OWNER SHALL PROVIDE ALL WATER AND POWER AS NECESSARY TO COMPLETE THE WORK DESCRIBED WITHIN. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND MAINTAINING ALL INTERCONNECTS FOR WATER & POWER IN SAFE MANNER. 3. CONTRACTOR ACKNOWLEDGES WORK AREA ACCESS, STAGING AREAS, ETC. WILL BE IDENTIFIED AND APPROVED BY THE OWNER PRIOR TO COMMENCEMENT OF THE PROJECT. NO WORK SHALL IMPACT HIGH TRAFFIC/HIGH VISIBILITY AREAS. 4. CONTRACTOR SHALL NOT DISTURB OCCUPANTS OR GENERAL PUBLIC WITH NOISE/DUST/LIGHTING OR ANY OTHER PROJECT RELATED ACTIVITIES CONDUCTED ON SITE. 5. THE CONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING ALL WORK WITH OTHER TRADES, BUILDING OWNER AND OWNER'S REPRESENTATIVE, INCLUDING BUT NOT LIMITED TO ISOLATION, DE-ENERGIZING MECHANICAL SYSTEMS IN PREPARATION FOR REMOVAL/DEMOLITION. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING SITE SECURITY REGARDING PROTECTION FROM EXCAVATION AREAS, EQUIPMENT, SUPPLIES, WASTE, ETC. 7. THE ABATEMENT CONTRACTOR ACKNOWLEDGES THAT ANY QUANTITIES/MEASUREMENTS, ETC. PROVIDED ON THIS DRAWING ARE FOR INFORMATIONAL PURPOSES ONLY. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING SITE CONDITIONS AND CONFIRMING ANY AND ALL MEASUREMENTS FOR BID PREPARATION PURPOSES. 8. ALL PARTIES ACKNOWLEDGE THAT LEAD-CONTAINING MATERIALS, LEAD-BASED PAINTED COMPONENTS MAY EXIST IN AREAS SCHEDULED TO BE IMPACTED BY THE UPCOMING PROJECT. ALL PARTIES ARE RESPONSIBLE FOR REVIEWING THE LIMITED HAZARDOUS MATERIALS PRE-RENOVATION SURVEY REPORT AND TAKING APPROPRIATE MEASURES REGARDING REGULATORY COMPLIANCE REGARDING HANDLING AND/OR DISPOSAL. 7 7 3 6 7 6 6 8 7 8 8 4 47 4 4 GYPSUM BOARD / METAL STUD SERIES PARTITIONS6" METAL STUDS AT 16" O.C.(1) LAYER 5/8" GYPSUM BOARD AT ROOM SIDE ONLY.2 1/2" METAL STUDS AT 16" O.C.(1) LAYER 5/8" GYPSUM BOARD AT ROOM SIDE ONLY.4" CMU WITH HORIZONTAL REINFORCING AT 16" O.C. (VERT.)4 7/8"3 5/8" METAL STUDS AT 16" O.C.(1) LAYER 5/8 " GYPSUM BOARD EACH SIDE.1 HOUR FIRE RESISTANT RATED WHEN INDICATED(WITH OR WITHOUT INSULATION) PER UL U419A37 1/4"6" METAL STUDS AT 16" O.C.(1) LAYER 5/8" GYPSUM BOARD EACH SIDE.1 HOUR FIRE RESISTANT RATED WHEN INDICATED(WITH OR WITHOUT INSULATION) PER UL U419A6UNBALANCED SERIES PARTITIONS3 3/8"U66 5/8"U10CMU SERIES PARTITIONS3 5/8"C4ALL STUD PARTITIONS NOT INDICATED WITH APARTITION TYPE SHALL BE TYPE U6.ALL MASONRY PARTITIONS NOT INDICATED WITH APARTITION TYPE SHALL BE TYPE C4.PARTITIONS WITH SOUND ATTENUATION BLANKETS:GYPSUM BOARD TO BE "TYPE X" UNLESS OTHERWISE NOTEDALL PARTITIONS ARE TO BE TO THE UNDERSIDE OF DECK UNLESS OTHERWISE NOTEDDIMENSIONS SHOWN FOR EACH PARTITION DESCRIPTION INDICATE FACE-TO-FACETHICKNESS OF MATERIALS LISTED FOR THAT PARTITIONPROVIDE LISTED U.L. FIRE-RESISTANT JOINT ASSEMBLIES @ TOP OF ALL WALLS INDICATED TO BE FIRE-RESISTANT RATEDTHE TOP OF ALL PARTITIONS FRAMED AGAINST THE UNDERSIDE OF STRUCTURES SHALL HAVE PROVISIONS FOR DEFLECTION & RESTRAINT. REFER TO DETAIL 1/A-000.PROVIDE BULLNOSE BLOCK AT ALL EXPOSED OUTSIDE CORNERS OF CMU PARTITIONSPROVIDE CONTROL JOINTS IN GYPSUM BOARD WALLS & CEILINGS. FOR CEILINGS: • INSTALL CONTROL JOINT IN AREAS EXCEEDING 2500SF. • SPACE CONTROL JOINTS NOT MORE THAN 50 FEET O.C.• INSTALL CONTROL JOINTS WHERE CEILING FRAMING OR FURRING CHANGES DIRECTION. FOR PARTITIONS AND FURRING: • INSTALL CONTROL JOINTS IN PARTITIONS AND WALL FURRING RUNS EXCEEDING 30 FT.• SPACE CONTROL JOINTS NOT MORE THAN 30 FT O.C. • INSTALL CONTROL JOINTS IN FURRED ASSEMBLIES WHERE JOINTS OCCUR IN BASE SUBSTRATE OF EXTERIOR WALLS. FOR STUD CONSTRUCTION NOT EXTENDING TO THE STRUCTURE, PROVIDE DIAGONAL BRACING FROM TOP OF WALL TO STRUCTURE ABOVE. INSTALL AT 12'-0" MAX SPACING AND @ EACH DOOR JAMBREFER TO CODE COMPLIANCE PLANS FOR PARTITION FIRE RESISTANCE RATINGS.GYPSUM BOARD JOINT TREATMENT IN CONCEALED SPACES SHALL BE FIRE TAPED. UNLESS OTHERWISE INDICATED IN A SPECIFIC UL DESIGN, JOINTS SHALL BE FIRE TAPED, AND JOINTS AND FASTENER HEADS COVERED WITH (1) COAT OF JOINT COMPOUND. BASE LAYERS IN MULTI-LAYER SYSTEMS ARE NOT REQUIRED TO HAVE JOINTS OR FASTENER HEADS TAPED OR COVERED WITH JOINT COMPOUND. GENERAL PARTITION NOTES:A.B.C.D.E.F.G.H.I.J.K.L.GENERAL NOTES:ALL GENERAL NOTES PERTAIN TO ALL ARCHITECTURAL (A-SERIES) DRAWINGS IN THIS SETFOR NEW OPENINGS IN EXISTING MASONRY WALLS; GENERAL CONTRACTOR SHALL PROVIDE THE DEMOLITION, LINTEL INSTALLATION AND RECONSTRUCTION. GENERAL CONTRACTOR TO PROVIDE ALL LOOSE LINTELS AT ALL MASONRY OPENINGS EXCEEDING 16" WIDE INCLUDING, BUT NOT LIMITED TO: DOORS, WINDOWS, F.E.C.S., DUCTS, ETC. LINTEL LOCATIONS FOR PLUMBING, ELECTRICAL AND MECHANICAL WORK ARE NOT SHOWN ON THE ARCHITECTURAL DRAWINGS. CONTRACTOR SHALL COORDINATE WITH RESPECTIVE DRAWINGS. ASSUME ALL EXISTING WALLS ARE MASONRY UNLESS INDICATED OTHERWISE.WHERE DIFFERENT FLOORING MATERIALS MEET, AND A SPECIFIC TRANSITION DETAIL IS NOT INDICATED, PREPARE SUBSTRATE WITH A TRANSITION HEIGHT BUILD UP USING TROWELABLE LEVELING AND PATCHING COMPOUND TO PRODUCE A FLUSH SMOOTH CONDITION. TROWEL MATERIAL FOR A MINIMUM DISTANCE OF 2 FEET FROM A FEATHER EDGE CONDITION UP TO A MAXIMUM SINGLE LAYER APPLICATION THICKNESS OF 1/2". FOR APPLICATIONS THICKER THAN 1/2", PLACE MATERIAL IN SUCCESSIVE LAYERS, SCORING PREVIOUS LAYER, UP TO A MAXIMUM THICKNESS OF 1".PROVIDE CONCEALED STEEL STUD BLOCKING OR 4" x 18 GA CONTINUOUS STEEL STRAPPINGATTACHED TO FACE OF STUDS BEHIND ALL WALL MOUNTED ITEMS SUCH AS: WALL CABINETS,SHELVING, COAT RODS, ETC. SEE INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION AND SCOPEFLOOR FINISH TRANSITIONS/CHANGES SHALL OCCUR BELOW THE DOORDIMENSIONS LOCATING INTERIOR PARTITIONS ARE TO THE FACE OF WALL (EXCLUDING FINISHMATERIALS SUCH AS -BUT NOT LIMITED TO: CERAMIC TILE, AND WOOD PANELING) UNLESS NOTED OTHERWISE. SEE PARTITION SCHEDULE FOR WALL THICKNESSALL EXISTING DIMENSIONS ARE APPROXIMATE AND FOR CONTRACTORS VERIFICATIONS. IFDISCREPANCIES ARISE, NOTIFY THE ARCHITECT (AND/OR CONSTRUCTION MANAGER) PRIORTO PROCEEDING WITH THE WORK THAT MAY BE EFFECTED BY THE DIMENSION CHANGEEVERY ATTEMPT HAS BEEN MADE TO INDICATE PERTINENT EXISTING UTILITIES AND CONDITIONSAS ACCURATELY AS POSSIBLE FROM EXISTING SURVEYS, DRAWINGS AND OTHER DATA. PRIORTO THE BID OPENING, CONTRACTORS SHALL WALK THE JOB SITE AND SATISFY THEMSELVESTO EXISTING CONDITIONS. THE ARCHITECT SHALL BE CONSULTED WHEN ANY QUESTIONARISES RELATIVE TO MATERIALS NOT SPECIFICALLY SHOWN OR SPECIFIEDALL EXISTING WORK (CEILINGS, FLOORS, WALLS, PARTITIONS, FINISHES, ETC.) DISTURBED BY NEW CONSTRUCTION, INCLUDING MECHANICAL, PLUMBING, AND ELECTRICAL, SHALL BE PATCHED AND REPAIRED TO RESTORE SURFACES TO THE ORIGINAL CONDITION AFTER INSTALLATION OF OTHER WORKPENETRATIONS THROUGH FIRE-RESISTANT CONSTRUCTION SHALL BE BUILT IN ACCORDANCEWITH U.L. LISTED THROUGH-PENETRATION FIRESTOP SYSTEMS. SEE CODE COMPLIANCE PLANFOR PARTITION LOCATIONS. PENETRATIONS THROUGH NON FIRE-RESISTANT RATEDHORIZONTAL ASSEMBLIES, NOT PROTECTED BY A SHAFT ENCLOSURE, SHALL HAVE ITSANNULAR SPACE FILLED WITH NON-COMBUSTIBLE MATERIAL TO PREVENT THE PASSAGE OFFLAME, SMOKE FUMES, AND HOT GASES. NON-COMBUSTIBLE PENETRATING ITEMS SHALL NOTPENETRATE MORE THAN 3 FLOOR ASSEMBLIES. COMBUSTIBLE PENETRATING ITEMS SHALL NOTPENETRATE MORE THAN 1 FLOOR ASSEMBLY1.2.3.4.5.6.7.8.9.10.PROVIDE SOUND ATTENUATION BLANKETS IN ALL CAVITY SPACES IN WALL FULL HEIGHTTHICKNESS OF BLANKETS IN STUD WALLS SHALL BE EQUAL TO THICKNESS OF CAVITY TO NEAREST 1/2", UNLESS INDICATED OTHERWISEPARTITIONS TO BE SEALED @ THE PERIMETER, BEHIND CONTROL JOINTS, AROUND OPENINGS AND AT ALL PENETRATIONS WITH EACH LAYER OF BOARD TO RECEIVE A BEAD OF NON-HARDENING SEALANTSEE WALL TYPE DESCRIPTIONS FOR CONDITIONS REQUIRING MINERAL FIBER SAFING INSULATION BATTS1.2.3.4.LEGENDINDICATES PARTITION TYPEINDICATES PARTITION HEIGHT ABOVEFINISHED FLOOR:"X" AFCPARTITION TO X" ABOVEFINISHED CEILINGUFCPARTITION TO UNDERSIDE OF FINISHED CEILINGX'-X"WHERE HEIGHT IS NOTED,CONSTRUCT WALL TO THATHEIGHT INCLUDING TOP OFWALL CAPXX**A3INDICATES PARTITION TYPEINDICATES ADDITIONAL SOUND ATTENUATIONBLANKETS FOR ACOUSTICAL PURPOSES(REFER TO GENERAL PARTITION NOTES)AREFER TO CODE COMPLIANCE PLAN(S) FOR PARTITIONS REQUIRED TO BE FIRE-RESISTANT-RATED CONSTRUCTION.(1) LAYER 5/8" GYPSUM BOARD LAMINATED TO SUBSTRATE INDICATED5/8"U17/8" METAL FURRING CHANNELS AT 16" O.C.(1) LAYER 5/8" GYPSUM BOARD AT ROOM SIDE ONLY.1 1/2"U3UPPER PART OF FLUTED DECKSCREW FASTENER TO STUDS ONLY2" x 20 GA. MIN DEEP LEG DEFLECTION TRACKCONT. LATERAL BRACE WITHIN 12" OF TOP TRACK 1 1/2 C.R. CHANNEL W/ 16 GA. CLIP ANGLE OR CONT. STRAPPING ON EA. SIDESTEEL STUDCUT STUDS 1" SHORT OF DECK OR BEAMGYPSUM BOARD -EXTEND TO TOP OF STUD ELEVATIONUNDERSIDE OF FLUTED DECK OR BEAMAT FIRE -RATED PARTITIONS:CONSTRUCT DETAIL IN ACCORDANCE WITH U.L. LISTED FIRE-RESISTANT JOINT SYSTEMS (HW-D). PROVIDE DEFLECTION TRACK ASSEMBLIES, FORMING/ FILL MATERIALS AND GYPSUM LINED SHEET METAL RESTRAINING ANGLES AS REQUIRED BY APPROVED JOINT SYSTEMAT NON-RATED PARTITIONS & SMOKE PARTITIONS: FOR PARTITIONS CONTAINING SOUND BATT INSULATION FILL FLUTES OF DECK WITH BATT INSULATION AND SEAL BOTH SIDES WITH SEALANT4"EXISTING DOOR FRAMETEAR-AWAY BEAD AT HEAD AND JAMBS, TYP.SCHEDULED PARTITION TYPE "U1"EXISTING CMU PARTITIONThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions5/20/2020 10:18:52 AMC:\1-Local Revit Models 2019\19700.00_Cornell Olin Chem Lab 573-580_Arch_R19_central_walkup54.rvt19700.00SDFGeneral Notes &LegendsCWJCREA-000100% ConstructionDocumentsCornell UniversityS.T. Olin Chemistry ResearchWing -Chem Lab 573-580RenovationFacilities & Campus Services -Humphreys Service Building,Ithaca, NY 1485305/22/2020AB Anchor boltA/C Air condition(ing) (ed)ACC AccessibleACCU Air cooled condensing unitACI American Concrete InstituteACT Acoustical ceiling tileACM Asbestos containing materialACOUS PNL Acoustical panelACS PNL Access panelADDL AdditionalADJ Adjustable, adjacentADH AdhesiveAFF Above finished floorAGGR AggregateAHU Air handling unitAISC American Institute of Steel ConstructionAISI American Iron and Steel InstituteALT AlternateALUM AluminumANOD AnodizedAPPROX ApproximateARCH Architect(ural)ARD Auxillary roof drainASD Allowable stress designASTM American Society for Testing and MaterialsAWP Acoustical wall panelAWS American Welding SocietyBAT BattenB/B Back to backB BD Base boardBCNYS Building Code of New York StateBITUM BituminousBD BoardBLDG BuildingBLKG BlockingBM Beam, BenchmarkBOT BottomBR BedroomBRG BearingBRZ BronzeBSMT BasementBTWN BetweenBUR Built up roofingBW Both waysCCTV Closed circuit televisionCAB CabinetCB Catch basin, Corner beadCH BD ChalkboardCEM CementCF Contractor furnishedCFMF Cold-formed metal framingCF/CI Contractor furnished/ Contractor installedCF/OI Contractor furnished/ Owner installedCG Corner guardCH Coat hookCI Cast ironCIP Cast in place, Cast iron pipeCJ Control jointCL CenterlineCLG CeilingCLO ClosetCLR Clear, ColorCMT Ceramic mosaic tileCMU Concrete masonry unitCNTR CounterCO Cleanout, Cased opening, CompanyCOL ColumnCONC ConcreteCONF ConferenceCONN Connect(ion)CONSTR ConstructionCONT Continue(ous)CONTR Contract(or)COORD CoordinateCPT CarpetCSJ Construction jointCSK Counter sunkCT Ceramic tile, Count, Current transformerCTR CenterCW Cold water piping, Casement windowCU CubicCUH Cabinet unit heaterCU YD Cubic yardD Deep, DepthD Penny (nail)db Bar diameterDBL DoubleDEFS Direct-applied exterior finish systemDEG DegreeDEMO DemolitionDEPT DepartmentDET DetailDF Drinking fountainDIA OR ø DiameterDIAG Diagonal, DiagramDIM DimensionDIFF DiffuserDIR DirectionDISP DispenserDIV DivisionDMPF Damp proofingDL Dead loadDN DownDO DittoDR Door, DriveDS DownspoutDW DishwasherDWVDrainage waste & ventDWGDrawingDWLDowelEEastEAEachEBCNYSExisting Building Code of New York StateECElectrical contractorEFEach faceEIFSExterior insulation and finish systemEJExpansion jointELASElastomericELElevationELECElectric(al)ELEVElevatorEMEntry mat, Expanded metalEMEREmergencyENCLEnclosureENGREngineerEOSEdge of slabEPElectric panelEQEqualEQUIPEquipmentESEmergency showerETCEt ceteraETRExisting to remainEWEach wayEWCElectric water coolerEXISTExistingEXCExcavation, ExcavateEXPExpand, ExpansionEXTExterior, External, ExtinguisherF/FFace to faceFAAPFire alarm annunciator panelFACPFire alarm control panelFDFloor drainFDTNFoundationFEFire extinguisherFECFire extinguisher cabinetFHCFire hose cabinetFINFinish(ed)FIXTFixtureFLASHFlashingFLEXFlexibleFLOURFluorescentFLGFlooring, flangeFOFinished openingFPFire protection, FireproofFRTWFire retardant treated woodFTFoot, FeetFTGFootingFTRFinned tube radiationFURNFurnace, Furniture, FurnishFUTFutureFWCFabric wall coveringGAGageGALGallonGALVGalvanizedGBGrab barGCGeneral contract(or)GFRCGlass fiber reinforced concreteGFRGGlass fiber reinforced gypsumGLGlass, Ground levelGL BLKGlass blockGLU LAMGlued laminated beamGRGrade, GrossGWTGlazed wall tileGYPGypsumGYP BDGypsum boardGYP PLASGypsum plasterHBHose bibbHCHollow core, Hose cabinetHCPHandicappedHDWHardwareHDWDHardwoodHMHollow metalHOHold openHORIZHorizontalHPHigh point, HorsepowerHRHourHSSHollow structural sectionHTHeightHTGHeatingHTRHeaterHVACHeating, ventilating and air conditioningHWHot waterHYDHydrantIDInside diameterINInchesINCLIncludedINCANDIncandescentINFOInformationINSULInsulationINTERMIntermediateINTInteriorJANJanitorJSTJoistJTJointKIP1000 PoundsKITKitchenKOKnockoutKPLKick plateLLiter, AngleLAMLaminate(d)LAULaundryLAVLavatoryLBPoundLBLLabelLDLoadLFLinear feet (foot)LHLeft hand, Latent heatLINLinearLKRLockerLLLive loadLLHLong leg horizontalLLVLong leg verticalLOCLocationLRFDLoad & resistance factor designLTLightLTGLightingLWCLight-weight concreteMACHMachineMAINTMaintenanceMASMasonryMATLMaterialMAXMaximumMCMechanical contractorMCBMetal corner beadMDOMedium density overlayMDFMedium density fiberboardMECHMechanicalMEPMechanical, electrical, plumbing and fire protectionMEZZMezzanineMFRManufacturerMHManholeMMMillimeterMIFRCMastic/intumescent fire-resistive coatingMINMinimumMISCMiscellaneousMLWKMillworkMOMasonry openingMRK BDMarker boardMTDMountedMTLMetalMULLMullionNNorthNATNaturalNCOMBLNoncombustibleNICNot in contractNO OR #NumberNOMNominalNORMNormalNRCNoise reduction coefficientNTSNot to scaleNWCNormal weight concreteO/OOut to outOAOverall, Outside airOCOn centerODOutside diameterOF/CIOwner furnished, Contactor installedOF/OIOwner furnished, Owner installedOFDOverflow drainOFFOfficeOHOpposite handOH DROverhead (coiling) doorOPNGOpeningOPPOppositeOPTOptional, OptimumOZOuncePAPublic addressPBDParticleboardPCPlumbing contractor, Portland cementPCCPrecast concretePCTPorcelain ceramic tilePEDPedestalPENDPendantPERPeriodPERFPerforatedPGBDPeg boardPLPlate, Property linePLFPonds per linear footPLAMPlastic laminatePLASPlasterPLBPlumbingPLYWDPlywoodPNLPanelPOLPolishedPORCPorcelainPOSPositive, PositionPPTPressure-preservative treatedPRPairPREFABPrefabricatePREFINPrefinishPREPPreparationPROJProjectPROJ SCRN Projection screenPSFPounds per square footPSIPounds per square inchPTPaint, Post tensionPTNPartitionPVCPolyvinyl chloride (plastic)PVGPavingQTQuarry tileQTRQuarterQTYQuantityRRiser, Radius, Thermal resistanceRBRubber base, Resilient baseRCPReinforced concrete pipe, Reflected ceiling planRDRoof drain, RoadRECRecessedREFRefrigeratorREFLReflectREGRegister, RegulationREINFReinforcedREQDRequiredRESILResilientREVRevisionRFResilient flooringRFGRoofingRHRight hand, Roof hatchRMRoomRORough openingROWRight of wayRTURoof top unitRVRoof ventRWBRubber wall baseSSouthSABSound attenuation battsSANSanitarySCSolid core, Shading coefficientSCHEDScheduleSEALSealer on floor (finish)SECTSectionSFSquare foot, Safety factorSFRMSprayed fire-resistiveMaterialSGTStructural glazed tileSHTSheetSHRShowerSIMSimilarSOGSlab on gradeSPStandpipe, Sump pitSPASpacesSPKRSpeakerSPECSpecificationSQSquareSRDSecondary roof drainSSService sinkSSMSolid surface materialSSPStainless steel pipeSSTStainless steelSTStainSTAStationSTCSound transmission classSTDStandardSTIFFStiffenerSTLSteelSTORStorageSTRStraight, StringersSTRUCTStructuralSUSPSuspendedSVSheet vinylSYSquare yardTTreadT/Top ofT&BTop and bottomT&GTongue and grooveTELTelephoneTHRESThresholdTEMPTemporaryTERTerrazzoTHKThick(ness)TK BDTack boardTMPDTemperedTOCTop of concreteTOMTop of masonryTOPOTopography, TopographicTOSTop of steelTOWTop of wallTPDToilet paper dispenserTSTATThermostatTVTelevisionTYPTypicalUHeat transfer coefficientUCUndercutUCLUnder cabinet lightingUGNDUndergroundUHUnit heaterULUnderwriter's laboratoriesUNEXUnexcavatedUNFINUnfinishedUONUnless otherwise notedUTILUtilityUVUnit ventilatorVARNVarnish(ed)VBVinyl baseVCTVinyl composition tileVENTVentilationVERTVerticalVESTVestibuleVIFVerify in fieldVINVinylVOLVolumeVRVapor retarderVTVinyl tileV SHTVinyl sheetVWCVinyl wall coveringWWestW/WithWCWater closet, Wall coveringW/OWithoutWDWoodWDWWindowWFWide flangeWD GDWood guardWHWater heaterWIWrought ironWMWire meshWPWaterproofing, Working pointWRWater repellent, weather resistantW RECPTWaste receptacleWSCTWainscotWTWeight, Watertight, Water tableWWFWelded wire fabricXByYDYardC12AC12A-XXX1432XSCALE: X"=1'-0"Title112BA18'-0" AFF1Batt insulationRigid insulationWood blocking (intermittent) StoneGravel or crushed stoneWood framing (continuous)Finish woodSteel -large scaleSteel -small scalePlywoodConcreteConcrete masonry unitBrick(Other metals as noted)View titleBuilding / wall section cutDetail -blow upExterior elevationInterior elevations1011Partition typeRoom numberDoor numbersWindow typeRevisionORORUndisturbed earth001100A001Structural gridViewing directionDetail no.Drawing no.Detail no.Drawing no.Drawing no.Elevation no.Plan key noteDemolition key noteCeiling type and heightDrawing symbols(Other metals as noted)A-XXXXA-XXXXGypsum, sand, mortarA-XXXXDrawing no.Elevation no.Detail no.Detail section cutDetail no.DRAWING NO.A-XXXXViewing directionAccessibilityAccessible unitV/HAUVisual / hearing accommodation unitMaterial symbolsArchitectural / Structural abbreviations3" = 1'-0"1Typ. Deflection Head Detail1 1/2" = 1'-0"2Partition U1 Detail FEFEFE12345678910111213ABCDELAB580AP.I. OFFICE582ASTAIR500SBMECH500UDLAB573LAB575LAB572LAB571WOMEN'S500TBOFFICE58211111' - 8 1/4"211' - 8 1/4"2319' - 8 7/8"9' - 8 3/8"3455EXISTING PIPE CHASE TO REMAIN6128989101111111313131414141111151516161717181921ACID WASTE RISER TO REMAINACID WASTE RISER TO REMAINPIPE TO REMAIN214202 1/2" VIFALIGN222472323232323222526WRITE-UP572AWRITE-UP570ALAB570ELEVATOR500EAELEVATOR500EBMECH500UCCORRIDOR500CA550JMECH500UE56928272A-1012A-101SIMGENERAL DEMOLITION NOTES:EVERY ATTEMPT HAS BEEN MADE TO DOCUMENT PERTINENT EXISTING CONDITIONS FROM EXISTING SURVEYS, DRAWINGS AND LIMITED FIELD INSPECTION. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS SHALL WALK THE SITE AND SATISFY THEMSELVES TO EXISTING VISUAL CONDITIONS. THE ARCHITECT SHALL BE CONSULTED WHEN ANY QUESTION ARISES RELATIVE TO MATERIALS AND CONDITIONS NOT SPECIFICALLY SHOWN OR SPECIFIED.ALL EXISTING WORK (CEILING, FLOORS, WALLS, FINISHES, ETC.) DISTURBED BY NEW CONSTRUCTION SHALL BE PATCHED AND REFINISHED. PATCHING AND FINISH WORK IS THE REPAIR WORK REQUIRED TO RESTORE SURFACES TO THE ORIGINAL CONDITION AND/ OR MATCHING THE ADJACENT SURFACES. MISCELLANEOUS FINISH REQUIREMENTS TO WALL, FLOOR AND CEILING IN AREAS AFFECTED BY DEMOLITION HAVE NOT BEEN TOTALLY INCORPORATED INTO THE ROOM FINISH SCHEDULE. REFER TO THE DEMOLITION , FLOOR AND REFLECTED CEILING PLANS FOR ADDITIONAL CUTTING , PATCHING AND REFINISHING WORK SCOPE.CONTRACTOR(S) SHALL COORDINATE ALL WORK WITH HAZARDOUS MATERIALS ABATEMENT WORK .THE EXISTING FIRE-RESISTANT CONSTRUCTION MUST BE MAINTAINED OR MADE TO COMPLY WITH THE REQUIREMENTS AS ESTABLISHED BY THIS CONTRACT. SEE THE CODE COMPLIANCE PLANS FOR THE FIRE RESISTANT RATINGS OF EXISTING AND NEW CONSTRUCTION.1.2.3.4.CARE SHALL BE TAKEN TO LIMIT IMPACT OF CONSTRUCTION ON THE SURROUNDING OCCUPANTS AND OPERATIONS DURING THE PROJECT. SAFE LEGAL PASSAGES SHALL BE PROVIDED FOR ALL BUILDING OCCUPANTS DURING ALL THE PHASES OF THIS PROJECT.WHEN EXISTING CONSTRUCTION WHICH IS TO REMAIN IS DAMAGED DURING THE COURSE OF CONSTRUCTION AS A RESULT OF CONTRACTOR'S WORK, IT SHALL BE REPAIRED AND/OR REPLACED WITH SIMILAR OR LIKE MATERIALS, SUBJECT TO ARCHITECT'S APPROVAL AND WITHOUT COMPENSATION.'REMOVE' IS DEFINED AS DETACH FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF OFF-SITE UNLESS INDICATED TO BE SALVAGED OR REINSTALLEDREMOVE AND SALVAGE ALL WALL-MOUNTED ITEMS AND ASSOCIATED COMPONENTS IN WORK AREA (I.E., WALL CLOCKS, COAT HOOKS/RODS, TACK BOARDS, MARKER BOARDS, WALL HANGINGS, WALL BRACKETS/STANDARDS) UNLESS NOTED OTHERWISE. PATCH AND REPAIR WALL TO MATCH ADJACENT SURFACE(S).CONTACT CORNELL CIT AT 255-5500 TO DISCONNECT ACTIVE INFORMATION TECHNOLOGY SERVICES AND REMOVE HARDWARE PRIOR TO DEMOLITION.5.6.7.8.9.CSIXTH FLOOR+104' -8"3"METAL LATH AND PLASTER SOFFITREMOVE HORIZONTAL PORTION OFVERTICAL SURFACE TO REMAINMETAL LATH & PLASTER SOFFITMETAL FRAMINGPLASTER AND METAL LATHMETAL ANGLESMETAL FRAMINGPLASTER AND METAL LATHMETAL ANGLEPROVIDE CLEAN CUT PLASTER EDGE AT CONTROL JOINT REMOVAL TO ACCOMODATE NEW CEILING SYSTEM INSTALLATIONCONTROL JOINTThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions5/20/2020 10:18:58 AMC:\1-Local Revit Models 2019\19700.00_Cornell Olin Chem Lab 573-580_Arch_R19_central_walkup54.rvt19700.00SDFFifth Floor DemolitionPlanCWJCREA-101100% ConstructionDocumentsCornell UniversityS.T. Olin Chemistry ResearchWing -Chem Lab 573-580RenovationFacilities & Campus Services -Humphreys Service Building,Ithaca, NY 1485305/22/20201/4" = 1'-0"1PARTIAL FIFTH FLOOR DEMOLITION PLANNORTHDEMOLITION NOTESNO.DESCRIPTION16REMOVE VENTED SOLVENT STORAGE CABINET. COORDINATE REMOVAL WITH MECHANICAL DRAWINGS.17REMOVE HORIZONTAL SURFACE OF GWB AND METAL STUD SOFFIT ONLY. VERTICAL GWB AND METAL STUDSOFFIT SURFACE TO REMAIN.18REFER TO HM DRAWINGS FOR REMOVAL OF ACM HOLLOW METAL DOOR, FRAME, AND ASSOCIATED HARDWARE.19PROVIDE ENLARGED OPENING IN +/-4" MASONRY WALL CONSTRUCTION. PROVIDE WT7x11 LINTEL.COORDINATE LOCATION WITH NEW WORK PLAN.20SAWCUT PORTION OF 4" CMU PARTITION21REFER TO HM DRAWINGS FOR REMOVAL OF ACM FLOOR TILE. GC TO PREP FLOOR TO RECEIVE SCHEDULEDFINISH UPON COMPLETION OF ABATEMENT WORK.22REFER TO HM DRAWINGS FOR REMOVAL OF ACM DOOR PANELS AND ASSOCIATED HARDWARE. TURN OVERHARDWARE TO OWNER. FRAME TO REMAIN. PREP FRAME TO RECEIVE SCHEDULED HARDWARE & DOORPANELS.23REMOVE SHELVING UNITS AND ASSOCIATED COMPONENTS.24REMOVE TACKBOARD & ASSOCIATED COMPONENTS.25REMOVE TRANSOM INFILL PANEL ABOVE DOOR26REMOVE AND SALVAGE FOR REINSTALLATION THE EXISTING WORK SURFACE, ADJUSTABLE SHELVES AND COATRACK TO ENABLE INSTALLATION OF PARTITION U3. COORDINATE WITH OWNER TO MINIMIZE DISRUPTION. WORKTO OCCUR CONCURRENTLY WITH THE INSTALLATION OF SPRINKLERS IN ROOM 570A AND THE FIRE DAMPERABOVE DOOR 570A.27ENLARGE OPENING IN +/-4" MASONRY WALL CONSTRUCTION FOR SCHEDULED DOOR AND FRAME. PROVIDEWT7x11 LINTEL. PATCH AND REPAIR JAMBS BY TOOTHING NEW CMU INTO EXISTING. COORDINATE LOCATIONWITH NEW WORK PLAN.28REMOVE HOLLOW METAL DOOR, FRAME, AND ASSOCIATED HARDWARE.DEMOLITION NOTESNO.DESCRIPTION1REMOVE SOLID SURFACE COUNTERTOP AND BACKSPLASH. STEEL CASEWORK AND CHASE COVERS HOUSINGMECHANICAL SYSTEMS AND ELECTRICAL RACEWAY TO REMAIN, SEE NEW WORK PLAN.2REMOVE COUNTERTOP, METAL BASE CABINET, UPPER SHELVING UNITS, SUPPORTS, AND ALL OTHERASSOCIATED COMPONENTS. COORDINATE LAB SERVICES WORK WITH PLUMBING DRAWINGS.3REFER TO HM AND M DRAWINGS FOR REMOVAL OF ACM FUME HOOD AND ASSOCIATED DUCTWORK.4REMOVE AND SALVAGE WALL-MOUNTED FIRE EXTINGUISHER FOR REINSTALLATION.5REMOVE VERTICAL BLIND ASSEMBLY AND ASSOCIATED HARDWARE IN ITS ENTIRETY. PATCH AND REPAIR TOMATCH ADJACENT SURFACES.6REMOVE HORIZONTAL BLIND ASSEMBLY AND ASSOCIATED HARDWARE IN ITS ENTIRETY. PATCH AND REPAIR TOMATCH ADJACENT SURFACES.7REMOVE CHALKBOARD & ASSOCIATED COMPONENTS.8REMOVE ACOUSTICAL CEILING TILES AND SUSPENSION SYSTEM IN ITS ENTIRETY.9REMOVE CARPET, WALL BASE, AND ADHESIVE. PREP FLOOR TO RECEIVE SCHEDULED FINISH.10REMOVE WOOD COAT ROD ASSEMBLY IN ITS ENTIRETY. PATCH AND REPAIR WALLS TO MATCH ADJACENTSURFACES.11REMOVE FREESTANDING OFFICE FURNITURE.12REMOVE PLEATED OPERABLE CURTAIN ASSEMBLY AND ASSOCIATED HARDWARE IN ITS ENTIRETY. PATCH ANDREPAIR TO MATCH ADJACENT SURFACES.13REMOVE GAS TANKS AND SAFETY RESTRAINT BRACKETS/CHAINS.14REMOVE FREESTANDING LAB CASEWORK AND WORK SURFACES.15REMOVE METAL SHELVING UNIT.#INDICATES DEMO KEYNOTE.#INDICATES DEMO KEYNOTE.3/4" = 1'-0"2Detail -Soffit Demolition FEFEFEGENERAL NEW WORK NOTES:ALL FLOORS, WALLS, CEILINGS, AND OTHER SURFACES THAT ARE TO REMAIN ARE TO BE PATCHED, REPAIRED, AND REFINISHED PRIOR TO FINISH INSTALLATION. ALL SURFACES ARE TO BE RESTORED TO THEIR ORIGINAL CONDITION AND/OR MATCH THE ADJACENT SURFACES.FIRESTOP ALL FLOOR PENETRATIONS (USED/UNUSED/ABANDONED) WITH 2 HR UL LISTED PENETRATION FIRESTOPPING.CONSTRUCT TEMPORARY PROTECTION OVER GLASS MANIFOLDS IN OCCUPIED LAB SPACES DURING SPRINKLER INSTALLATION.1.2.3.1234567891011121314ABCDEA-4205473A-42021A-42086379LAB580AWRITE-UP580P.I. OFFICE582AOFFICE582STAIR500SBMECH500UDWOMEN'S500TBCORRIDOR500CALAB571LAB573U6U6U69' - 4"2' - 2"2' - 1"+/- 4' - 4 1/4"5' - 0"5' - 0"5' - 0"4' - 0"122213145' - 8 3/4"1' - 0"5' - 0"6' - 0"+/- 4' - 1 3/4"2335556669999111222122212221081516179' - 0"5' - 0"6' - 0"2' - 3"9' - 7 1/4"A-42012A-42091110U10181919421202523555555573A-6011182323232323232323M.O.3' - 2"2' - 4"A-6012580A2412224A-5012A-5013A-5012A-5015A-5012' - 3"4"4"5"EQEQEQEQ5"4"4"EQEQEQEQ5"5"5"2' - 6"EQEQEQEQ5"5"+/- 4' - 4 1/2"3' - 11"U1U1U1U1U1U1U1U1U1U110A-501U1U1U1U1U1580500CAA3MECH500UERoom550JRoom569CORRIDOR500CACORRIDOR500CAMECH500UCELEVATOR500EBELEVATOR500EALAB570WRITE-UP570AWRITE-UP572ALAB572570A2' - 2"U3U34A-1105A-110SEE RCP FOR PARTITION CONSTRUCTION ABOVE DOOR FRAMEPAINT PARTITIONS TO MATCH ADJACENT WALLS -LINEN WHITE TO APPROX. 8'-2" AFF, FLAT BLACK ABOVE.VIF2' - 0"SEE INTERIOR ELEVATIONS (A-420) FOR HEIGHT. TYPICAL, UON.VIF10' - 5 1/4" x 6' - 2" HIGH23VIF2' - 1" x 6' - 2" HVIF3' - 9" x 6' - 2" H7A-5013' - 3"VIF10' - 0 1/2"U6U6U6ADJUSTABLE SHELVES AND COAT RACK.REINSTALL SALVAGED WORK SURFACE,A-4208SIMOPP6"6"6"U66"DATA AND POWER STACKED IN SINGLE-GANG BOXES, SEE ELECTRICAL DRAWINGS.DATA AND POWER STACKED IN SINGLE-GANG BOXES, SEE ELECTRICAL DRAWINGS.4"575AA-50114A-50113LAB5755' - 2"5/4 X 6 HARDWOOD TO MATCH EDGE OF COUNTERTOP.(4) STAINLESS STEEL BOBRICK B-6827 HOOKSSectionElevation2' - 6"EQTYP8"EQEQEQFINISH FLOORHEIGHT (WALL HUNG)2'-4" MOUNTINGSALVAGED EXTINGUISHER SALVAGED WALL HUNG BRACKETCOORDINATE LOCATIONS WITH THE FLOOR PLANS. WALL HUNG/BRACKET TYPE EXTINGUISHERS ARE DENOTED IN PLAN BY THE SYMBOL (FE)WALL HUNG/BRACKETMOUNTED EXTINGUISHERVIF+/- 8 3/4"EXIST HM FRAMEL-BEAD & SEALANT, TYP(2) LAYERS 5/8" GWBBENT METAL STOP1/4"1/4"4 1/8"1 1/8" VIF+/-5" HIGH PAINTED STENCILED ROOM NUMBER "570", CORRIDOR SIDE. FONT SWIS721 -VERIFY. CONFIRM SIZE AND FONT WITH PRINTED MOCK-UP FOR OWNER APPROVAL. ALUMINUM GLASS STOPS (BOD: TUBELITE EXTRUSIONS E0929 AND E0927). ALL FASTERNERS TO BE SST.BACKER ROD & SEALANT, TYP BACKER ROD & SEALANT, TYP 2"WALL BEYONDSCHEDULED GLASSThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions5/20/2020 10:19:05 AMC:\1-Local Revit Models 2019\19700.00_Cornell Olin Chem Lab 573-580_Arch_R19_central_walkup54.rvt19700.00SDFFifth Floor PlanCWJCREA-110100% ConstructionDocumentsCornell UniversityS.T. Olin Chemistry ResearchWing -Chem Lab 573-580RenovationFacilities & Campus Services -Humphreys Service Building,Ithaca, NY 1485305/22/2020NORTHPLAN KEY NOTESNO.DESCRIPTION12PROVIDE HOUSE NITROGEN AND AIR CONNECTIONS IN COUNTERTOP, SEE PLUMBINGDRAWINGS.13CARVER PRESS (OF/OI)14TENSILE TESTER (OF/OI)15ROTOVAP (OF/OI)16GLASSWARE OVEN (OF/OI)17COMPUTER ON MOVABLE COMPUTER CART (OF/OI)18ADA-COMPLIANT 18"W x 15"L x 5" D DROP-IN EPOXY RESIN SINK (VWR #SNKA-25-001)).1925"W x 15"L x 10" D DROP-IN EPOXY RESIN SINK (VWR #VF-1005-DI).20PROVIDE 48"W x 30" H STAINLESS STEEL PEG BOARD WITH DRIP TRAY AT 42" AFF TO BOTTOM.21PROVIDE 24"W x 30" H STAINLESS STEEL PEG BOARD WITH DRIP TRAY AT 42" AFF TO BOTTOM.22ADD ALTERNATE #1: PROVIDE NATURAL GAS CONNECTION IN COUNTERTOP, SEE PLUMBINGDRAWINGS.23ADD ALTERNATE #2: PROVIDE ALUM FRAMED STORM WINDOW W/ 1" THICK INSULATED GLASS@ INTERIOR OF EXISTING WINDOW. REFER TO SPEC FOR GLAZING TYPE.243'-0"W X 7'-4"H HM CASED OPENING, PT TO MATCH OTHER DOOR FRAMES25PROVIDE 36"W x 30" H STAINLESS STEEL PEG BOARD WITH DRIP TRAY AT 42" AFF TO BOTTOM.PLAN KEY NOTESNO.DESCRIPTION1PARGE & PAINT TO MATCH EXISTING @ CMU REMOVAL2REINSTALL SALVAGED WALL-MOUNTED FIRE EXTINGUISHER.3PROVIDE SOLID PHENOLIC COUNTERTOP AND BACKSPLASH TO MATCH REMOVEDCONFIGURATION. PREP AND PAINT EXISTING TO REMAIN STEEL CASEWORK AND PIPE CHASECOVERS HOUSING MECHANICAL SYSTEMS AND ELECTRICAL RACEWAY. REFER TO DETAIL7/A-501.4ADA-COMPLIANT DECK-MOUNTED EMERGENCY EYEWASH, COORDINATE WITH PLUMBINGDRAWINGS.5PROVIDE ROLLER SHADE ASSEMBLY AND ASSOCIATED MOUNTING HARDWARE.6PAINT EXISTING METAL RADIATOR ASSEMBLY AFTER CAULK ABATEMENT. COORDINATE WITHHM DRAWINGS.7PAINT EXISTING HOLLOW METAL DOOR AND FRAME TO MATCH EXISTING PAINT COLOR,ROOM-SIDE.8TOOTH-IN +/-4" MASONRY TO MATCH EXISTING AT ENLARGED FRAMED OPENING. PROVIDE L3.5 X 3.5 X 5/16 LINTEL, 8" BEARING EACH END.9PAINT EXISTING HOLLOW METAL FRAME (AND TRANSOM IF APPLICABLE) TO MATCH EXISTINGPAINT COLOR (BOTH SIDES).10PROVIDE 2-HOUR FIRE-RATED FIRESTOPPING AT ALL FLOOR PENETRATIONS.11PROVIDE 4-COAT HOOK WALL-MOUNTED RACK. SEE DETAIL 2/A-110.#INDICATES PLAN KEYNOTE.1/4" = 1'-0"1Partial Fifth Floor Plan3/4" = 1'-0"2Coat Rack Detail3/4" = 1'-0"3Fire Extinguisher Details#INDICATES PLAN KEYNOTE.1 1/2" = 1'-0"4Transom Infill Detail1 1/2" = 1'-0"5Add Alternate 2 -Storm Window Detail 18' -7 1/4"18' -6 1/2"LAB572LAB580AWRITE-UP580P.I. OFFICE582AOFFICE582STAIR500SBMECH500UDWOMEN'S500TBCORRIDOR500CALAB571LAB573LAB57518' -11"EXISTING PIPE CHASE TO REMAIN18' -11"EXISTING BULKHEAD AT +/-8'-10 1/2" AFFEXISTING BULKHEAD AT +/-8'-10 1/2" AFF18' -11"GWB & MTL STUD BULKHEAD ABOVE STOREFRONT, MATCH TO EXIST BULKHEAD HEIGHTA618' -11"4A-110B3PAINT ALL NEW WORK AT CEILING FLAT BLACKEXISTING PLASTER SOFFIT -REMOVE, PATCH AND PAINT TO MATCH WHERE REQUIRED FOR ACCESS TO INSTALL SPRINKLERS.FIRESTOP ASSEMBLY AT CABLE TRAY -SEE ELECTRICAL DRAWINGS3A-1303A-130SIMCEILING -LEGENDEXISTING STRUCTURE/CEILING TO REMAIN; RFS = ETRCEILING TYPE 1 -2 x 2 ACOUSTICAL CEILING TILE; RFS = ACT-1CEILING TYPE 2 -GYP. BD. CEILING AND/OR SOFFIT -PAINTCEILING TYPE MARKERSUPPLY DIFFUSER -REFER TO "M" SERIES DWGSRETURN DIFFUSER -REFER TO "M" SERIES DWGS2 x 4 FIXTURE -REFER TO "E" SERIES DWGSPENDANT LIGHT FIXTURE -REFER TO "E" SERIES DWGSRECESSED DOWNLIGHT -REFER TO "E" SERIES DWGSGENERAL NOTES:REFER TO MEP DWGS FOR ADDITIONAL INFORMATION AND COORDINATION.ALL GYPSUM BOARD SOFFITS AND BULKHEADS TO BE PAINTED, COLOR AS NOTED OR AS SELECTED BY ARCHITECT IF NOT INDICATED.PROVIDE BRACED GYPSUM BOARD BULKHEAD (A3 PARTITION TYPE) AT ALL CHANGES IN CEILING HEIGHTS, UNLESS OTHERWISE NOTED.EXISTING ACCESS PANELS IN EXISTING BULKHEAD/SOFFIT CONDITION TO REMAIN.XX' -X"CEILING TYPEHEIGHT AFF1.2.3.4.PT-XPAINT COLORLAB562WRITE-UP562AOFFICE560AOFFICE560CONFERENCE561WRITE-UP563LAB565LAB570STAIR500SAMECH500UAMENS'500TACORRIDOR500CAMECH500UBELEVATOR500EAELEVATOR500EBMECH500UCWOMEN'S500TBWRITE-UP570AWRITE-UP572ALAB572LAB580AWRITE-UP580P.I. OFFICE582AOFFICE582STAIR500SBMECH500UDMECH500UERoom550JRoom569LAB571LAB573LAB575REMOVE AND REINSTALL ACOUSTICAL CEILING TILES AS REQUIRED TO FACILITATE THE FIRE PROTECTION WORK, TYP.REMOVE PORTION OF PLASTER CEILING AS REQUIRED TO FACILITATE THE FIRE PROTECTION WORK. PATCH AND REPAIR TO MATCH ADJACENT SURFACES.SCHEDULED CEILING SYSTEMCEILING MOLDINGSEALANTEXISTING PLASTER SOFFITThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions5/20/2020 10:19:10 AMC:\1-Local Revit Models 2019\19700.00_Cornell Olin Chem Lab 573-580_Arch_R19_central_walkup54.rvt19700.00SDFFifth Floor ReflectedCeiling PlanCWJCREA-130100% ConstructionDocumentsCornell UniversityS.T. Olin Chemistry ResearchWing -Chem Lab 573-580RenovationFacilities & Campus Services -Humphreys Service Building,Ithaca, NY 1485305/22/2020NORTH1/4" = 1'-0"1PARTIAL FIFTH FLOOR REFLECTED CEILING PLAN1/16" = 1'-0"2Fifth Floor Reflected Ceiling Key Plan3" = 1'-0"3Detail -SoffitPROVIDE KICKERS OR HORIZONTALBRACES WHERE POSSIBLE TO STABILIZE PLASTER BULKHEAD 3' - 0"2' - 0"2' - 0"VIF2' - 9"VIF+/- 10' - 3 3/8"VIF+/- 3' - 1"EXISTING MECHANICAL PIPE CHASE TO REMAIN, PAINTEXISTING PIPE CHASE TO REMAINEXISTING MECHANICAL PIPE CHASE TO REMAIN, PAINTWD LAB CASEWORK, TYPSP-1 COUNTERTOPSOLID PHENOLIC COUNTERTOP & BACKSPLASH, SP-110A-501TABLE LEG @ 3'-0" OC MAXPLAM COUNTERTOP2' - 7"PLASTIC LAMINATE WORKSURFACE, PLAM-1 W/ SOLID OAK EDGEGWB SOFFIT ABOVEEXISTING MECHANICAL PIPE CHASE TO REMAINEXISTING ELECTRICAL PANEL TO REMAINCENTER-GLAZED STOREFRONT SYSTEM1A-5013' - 0"2' - 10"3' - 0"3' - 0"3' - 0"2' - 10"4' - 9"PEGBOARDPEGBOARDWD LAB CASEWORK, TYP.5' - 0"5' - 0"EXISTING MECHANICAL PIPE CHASE TO REMAIN, PAINT6A-5014' - 9"2' - 0"2' - 9"ACCESSIBLE SINK2' - 0"2' - 0"1' - 0"2' - 0"CASEWORKCASEWORKVIF7' - 3 1/4" TYP12A-5016" D WALL-MOUNTED SHELVING UNITS ON STANDARDSFRIDGE(NIC)VENTED FLAMMABLE CABINET (OF/CI)3' - 6"1' - 3"3' - 6"3' - 0"3' - 0"2' - 0"3' - 0"2' - 0"VENTED SOLVENT CABINETVENTED VACUUM PUMPFUME HOOD3' - 0"4' - 0"STL CABINETSWD LAB CASEWORK, TYP5A-5017' - 0"12"D WD FRAMED GLASS SLIDING DOOR CASE12"D WD FRAMED GLASS SWING DOOR CASELOCKABLE DRAWERCOORDINATE 3" VENT TO FLAMMABLE CABINET, REFER TO MECHANICAL DRAWINGSPILOT SWITCH FOR POWER TO VACUUM -LIGHTED RED WHEN "ON"PT1A-501A-13034 1/4" FILLERADA HT3' - 0"ADA HT3' - 0"2' - 10"FUME HOODELEC RACEWAY, TYP3' - 9"1' - 0"1" FILLERWD LAB CASEWORK, TYP.4A-5013A-5012" STL RAIL & END GABLEREMOVABLE CABINET, ADJACENT CABINET FACES AND BACKPANEL TO BE FINISHED.STL REMOVABLE CABINETS, ADJACENT CABINET FACES AND PANELS TO BE FINISHEDSTL CABINETLOCKABLE DRAWERVENTED SOLVENT CABINETPILOT SWITCH FOR POWER TO VACUUM -LIGHTED RED WHEN "ON". COORD WITH VACUUM PUMP BEHIND FUME HOOD.A-13033' - 0"2' - 10"3' - 0"2' - 0"3' - 0"3' - 0"VENTED SOLVENT CABINETVENTED VACUUM PUMPVENTED SOLVENT CABINETELEC RACEWAY, TYPBACK PANEL OF FUME HOODWD LAB CASEWORK, TYPWD CABINETS4A-5013A-501VENTED SOLVENT CABINETVENTED VACUUM PUMP3" FILLER3' - 0"3' - 0"2' - 0"3' - 0"FUME HOODELEC RACEWAY, TYPWD LAB CASEWORK, TYP.STL CABINETS3' - 0"2A-5011' - 10"LOCKABLE DRAWERPILOT SWITCH FOR POWER TO VACUUM -LIGHTED RED WHEN "ON"3' - 0"3' - 0"3' - 0"3' - 0"ROTOVAP (OF/CI)METAL STUD AND GWB PIPE CHASEPEGBOARDWD LAB CASEWORK, TYP.VENTED SOLVENT CABINETVENTED VACUUM PUMPFUME HOOD1' - 0"3' - 0"2' - 0"3' - 0"3' - 0"METAL CHASE ENCLOSUREELEC RACEWAY, TYP3' - 0"STL CABINETSWD LAB CASEWORK, TYP.LOCKABLE DRAWERPILOT SWITCH FOR POWER TO VACUUM -LIGHTED RED WHEN "ON"VENTED SOLVENT CABINETVENTED VACUUM PUMPFUME HOOD3' - 0"3' - 0"2' - 0"3' - 0"1' - 0"METAL CHASE ENCLOSUREELEC RACEWAY, TYP3' - 0"STL CABINETSWD LAB CASEWORK, TYP.2A-501LOCKABLE DRAWERPILOT SWITCH FOR POWER TO VACUUM -LIGHTED RED WHEN "ON"FRIDGE(NIC)3' - 0"3' - 0"3' - 0"3' - 0"EXISTING MECHANICAL PIPE CHASE TO REMAIN, PAINTTENSILE TESTER (OF/OI)CARVER PRESS (OF/OI)GLASSWARE OVEN (OF/OI)WD LAB CASEWORK, TYPVIF7' - 3" TYPThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions5/20/2020 10:19:15 AMC:\1-Local Revit Models 2019\19700.00_Cornell Olin Chem Lab 573-580_Arch_R19_central_walkup54.rvt19700.00SDFInterior ElevationsCWJCREA-420100% ConstructionDocumentsCornell UniversityS.T. Olin Chemistry ResearchWing -Chem Lab 573-580RenovationFacilities & Campus Services -Humphreys Service Building,Ithaca, NY 1485305/22/20201/4" = 1'-0"1WRITE-UP 580 -EAST ELEVATION1/4" = 1'-0"2WRITE-UP 580 -WEST ELEVATION1/4" = 1'-0"3LAB 580A -NORTH ELEVATION1/4" = 1'-0"4LAB 580A -SOUTH ELEVATION1/4" = 1'-0"5LAB 580A -EAST ELEVATION #11/4" = 1'-0"7LAB 580A -WEST ELEVATION #11/4" = 1'-0"6LAB 580A -EAST ELEVATION #21/4" = 1'-0"8LAB 580A -WEST ELEVATION #21/4" = 1'-0"9LAB 573 -NORTH ELEVATION #11/4" = 1'-0"10LAB 573 -NORTH ELEVATION #21/4" = 1'-0"11LAB 573 -SOUTH ELEVATION #11/4" = 1'-0"12LAB 573 -SOUTH ELEVATION #2 2' - 2"3/4"2' - 7"1 1/2"2"1' - 6 1/4"1 3/4"4' - 1"1 3/4"2' - 7 1/4"2"8' - 10"ALUMINUM STOREFRONT FRAMING SYSTEM1 3/4" X 4 1/2" MULLION PROFILE4 1/2" X 4 1/2" BASE PROFILEGLAZING AS SCHEDULEDMATTE BLACK ANODIZED FINISHSOLID OAK EDGE W/ EASED EDGES, STAIN TO MATCH CASEWORK1 1/2" PLAM FINISHED COUNTERTOP1/4" X 1 1/2" STL FLAT BAR ANGLE SUPPORT W/ 1" X 1" SQ. BAR BRACE. PAINT TO MATCH STOREFRONT. PROVIDE STL REINFORCMENT IN VERTICAL MULLION AND BOLT SUPPORT INTO REINFORCEMENT.1' - 10"6"6"1' - 10"ALUMINUM POWER & DATA RACEWAYS, SHOP PAINT TO MATCH STOREFRONT. SEE ELECTRICAL DRAWINGSFINISHED FLOORWD BLOCKINGBACKER ROD & SEALANT, EA SIDESCHEDULED CEILING6" MTL STUD AT 2'-0" OC MAXIMUM W/ 5/8" GYP BD, PTEXISTING CONC DECKMIN6"3 5/8" X 20 GA METAL STUD, DIAGONAL BRACING @ 4'-0" OC MAX1' - 8"5"3' - 0"5' - 0"1' - 1 1/4"1' - 9 1/2"2' - 10"REMOVABLE FINISHED WOOD PANEL AT FUTURE KNEE SPACEWOOD BASE CABINET BEYOND, FINISHED END PANELA-5016FASTEN CABINET TO FINISHED WOOD BACK PANEL WITH (4) SCREWS FOR FUTURE CABINET REMOVALUNISTRUT FRAME AT CHASEMICRO-LEVELERSDO NOT GLUE REMOVABLE CABINET TO COUNTERTOP.5' - 0"1' - 9 1/2"1' - 2"1' - 9 1/2"4' - 1"3' - 0"ISLAND UPRIGHTINNER & OUTER REAGENT SHELF W/ LIPDUAL-CHANNEL WIREMOLD, REFER TO ELECTRICAL DRAWINGSINVERTED REAGENT SHELFWOOD BASE CABINETSSOLID PHENOLIC COUNTERTOPPIPE CHASE1' - 0"1' - 0"4" SIDESPLASH AT FUME HOOD LOCATIONSUNISTRUT FRAME AT CHASE1' - 9 1/2"1' - 2"1' - 9 1/2"A-50165' - 0"4' - 1"3' - 0"2' - 10"SOLID PHENOLIC COUNTERTOP, SP-1WOOD BASE CABINETSCUP SINKUNISTRUT FRAME AT CHASEWD RAILS AT UNISTRUT FRAME, ALIGN WITH ADJACENT WD CABINETSTANDING OR ADA HEIGHTADA HEIGHT OR SITTING HEIGHTALIGN FRONT OF SIDESPLASH FLUSH WITH FRONT OF ADJACENT WORKSURFACES WHEN TRANSITIONING HEIGHTS2' - 6"7"4"3' - 0"WALL-MOUNTED ADJUSTABLE REAGENT SHELVES W/ LIPS3/4" SOLID PHENOLIC COUNTER W/ BACKSPLASH1' - 0"WOOD BASE CABINETSIDESPLASH AT FUME HOOD AND PARTITION LOCATIONSUNISTRUT FRAME AT CHASEFRONT ELEVATIONWORKSURFACEWORKSURFACESEE ELEVATIONSRECEPTACLELIGHT SWITCHRECEPTACLECASAFETY MONITOR/ ALARM5' - 0"SECTIONREMOVABLE ACCESS PANELAIRFOILLIGHT ENCLOSURE2' - 8" +/- OVERALLWATER3" x 6" CUPSINK N28"7 1/4"NOTE: TYPICAL ELEVATION AND SECTION FOR STANDARD FUME HOODS AS SHOWN. OPPOSITE HANDING AT ACCESSIBLE HOOD AND WHERE SHOWN ON THE FLOOR PLAN.CONNECTION FOR VACUUM5' - 0"2' - 8 5/8"5/8"5"5"2 1/4"3 3/4"2 1/2" DIA HOLE, TYP 2 PLACES1' - 4"2 7/16"1 1/2" DIA HOLE, TYP 2 PLACESR0.56 +/-0.12 AT TOP SURFACE, TYP 4 CORNERS3/8" TYPCOORDINATE DIMENSION TO AVOID FRAME BELOWCUP SINK9 3/4"7 1/4"HAFELE TABLE LEG, SQUARE, Ø60 mm, 635.36.380, 2-3/8" X 2-3/8", BLACK TEXTURED, AT 3'-0" OCVIF11"VIF2"EXISTING MECH CHASE PANELS, PAINT. DO NOT FASTEN INTO PANELS.ADJUSTABLE BASE FOR LEGHAFELE MOUNTING PLATE FOR SQUARE LEGELEC RACEWAY, REFER TO ELECTRICAL DRAWINGSSOLID PHENOLIC COUNTERTOP AND BACKSPLASH, SP-1VIF3' - 1"2' - 6"2' - 2"3/4"SOLID OAK EDGE W/ EASED EDGES, STAIN TO MATCH CASEWORK1 1/2" PLAM FINISHED COUNTERTOP5' - 0"2' - 8 5/8"5/8"5"5"2 1/4"3 3/4"2 1/2" DIA HOLE, TYP 2 PLACES1' - 4"2 7/16"1 1/2" DIA HOLE, TYP 2 PLACESR0.56 +/-0.12 AT TOP SURFACE, TYP 4 CORNERS3/8" TYPCOORDINATE DIMENSION TO AVOID FRAME BELOWCUP SINK1' - 1 1/4"7"EXISTING MECH CHASE PANELS, PAINT. DO NOT FASTEN INTO PANELS.SOLID PHENOLIC COUNTERTOP AND BACKSPLASH, SP-12" VIFELEC RACEWAY, REFER TO ELECTRICAL DRAWINGSVIF10"1"SCRIBE AROUND FUME HOOD LOCATIONSWD BASE CABINET BEYOND, FINISHED END PANEL2' - 10"2' - 3"5 1/2"8"6"FINISHED END PANELADJACENT REMOVABLE BASE CABINETCHASE2 3/4"EPOXY RESIN DROP-IN SINKFAUCET, REFER TO PLUMBING DRAWINGSSOLID PHENOLIC COUNTERTOP3/4" WD APRON W/ 2X4 WD NAILERREMOVABLE FRONT PANEL W/ (2) BALL CATCHES @ EA ENDDASHED LINE INDICATES 1" STANDARD AT OPPOSITE END3/4" FINISHED BACKERSCHEDULED BASE4A15A-501SOLID PHENOLIC COUNTERTOP AT +/-37" AFF, VIFSOLID PHENOLIC COUNTERTOP AT 36" AFF, VIFMECHANICAL CHASEEXTERIOR WALL2' - 4 3/8"SCRIBE COUNTERTOP AROUND FUME HOOD, TYP5E15A-501SOLID PHENOLIC COUNTERTOP AT +/-37" AFF, VIFSOLID PHENOLIC COUNTERTOP AT +/-36" AFF, VIFMECHANICAL CHASEEXTERIOR WALL9' - 0"1"SEALANTMECHANICAL CHASESOLID PHENOLIC COUNTERTOP AND BACKSPLASH, +/-37" AFF VIFELECTRICAL RACEWAY, REFER TO ELECTRICAL DRAWINGSSOLID PHENOLIC COUNTERTOP, +/-36" AFF VIFThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions5/20/2020 10:19:19 AMC:\1-Local Revit Models 2019\19700.00_Cornell Olin Chem Lab 573-580_Arch_R19_central_walkup54.rvt19700.00CheckerCasework DetailsCWJCREA-501100% ConstructionDocumentsCornell UniversityS.T. Olin Chemistry ResearchWing -Chem Lab 573-580RenovationFacilities & Campus Services -Humphreys Service Building,Ithaca, NY 1485305/22/20203/4" = 1'-0"1Section Through Write-up Countertop3/4" = 1'-0"4Section Through Accessible Bench at Knee Space3/4" = 1'-0"2Typical Section Through Bench3/4" = 1'-0"3Section Through Accessible Bench1 1/2" = 1'-0"6Worksurface Transition Detail3/4" = 1'-0"5Section Through Cup Sink3/4" = 1'-0"8Fume Hood Details3/4" = 1'-0"9Fume Hood Plan Detail3/4" = 1'-0"10Section Through Write-up Countertop (East)3/4" = 1'-0"11Fume Hood Plan Detail -Accessible3/4" = 1'-0"7Section Through Typical Mechanical Chase3/4" = 1'-0"12Section Through Accessible Sink3/4" = 1'-0"14Plan -Countertop Transition at 580A Chase3/4" = 1'-0"13Plan -Countertop Transition at 573 Chase1 1/2" = 1'-0"15Detail -Countertop Transition SWING CLEAR HINGESWING CLEAR HINGE18" MINEXISTING HM FRAME2' - 9"1' - 3"VIF2 1/2"PARGE & PAINT TO MATCH EXISTING @ CMU REMOVALSAWCUT PORTION OF 4" CMU PARTITIONEXISTING 4" CMU PARTITIONSGLAZING TYPES:S-11/4" FULLY TEMPERED SAFETY GLASSS-21/4" LAMINATED SAFETY GLASS (TRANSLUCENT)FP-13/16" 45-MIN FIRE-RATED LAMINATED CERAMIC GLAZINGFP-23/16" 90-MIN FIRE-RATED LAMINATED CERAMIC GLAZINGD1D2SEE DOOR SCHED FOR GLAZING TYPE, TYP.SEE DOOR SCHED FOR GLAZING TYPE, TYP.MAX3' - 7"SCHEDULESEE DOOR6"6"8"SCHEDULESEE DOOR4"8"MAX3' - 7"2' - 1"SEE DOOR SCHEDULESEE DOOR SCHEDULE100 SQ. IN MAXMAX3' - 7"2' - 1"SEE DOOR SCHEDULESCHEDULESEE DOOR4"8"D3SEE DOOR SCHED FOR GLAZING TYPE, TYP.D4SCHEDULESEE DOORSEE DOOR SCHEDULEWRITE-UP580U6U6U62' - 2"14' - 2 1/2"6' - 0 3/4"VIF1' - 5 1/4"EQEQVERIFY PIPE LOCATIONPROVIDE 12" X 12" ACCESS PANEL @ 48" AFF TO CENTERGROMMET, DOUG MOCKETT #RG3, MATTE BLACK, TYP.1' - 6"MODIFY EXIST MTL PIPE CHASE SUPPORTS, TRIM & COVER PANELS AS REQUIRED @ EA. SIDE OF CHASEA-6013A-6014STL REINFORCMENT WITHIN MULLION @ COUNTER LOCATION580AGYP BULKHEAD ABOVE (A6)1A-501VIF13' - 10 1/2"14' - 2 1/2"4' - 6"2"6' - 0 3/4"MATCH EXIST BULKHEAD+/- 8' - 10"1' - 10"4"2"EQ2"EQ2"EQ2"2"2"SEE DOOR SCHEDS-1S-1S-1S-1S-1S-1S-1S-1S-1S-2S-2S-21A-5012' - 11"1' - 10"MATCH EXIST BULKHEAD+/- 8' - 10"1' - 6"2"2"2"4"4"S-1S-1S-22"2' - 11"1.2.3.SWING-CLEAR HINGES, 1'-3" INACTIVE LEAF. COORDINATE WITH CORNELL EH&S FOR INSPECTION AFTER COMPLETE INSTALLATION.1'-6" INACTIVE LEAF1'-0" INACTIVE LEAFF1SEE DOOR SCHEDULE2"2"SCHEDULESEE DOOR2"J1VIFEXIST PARTITIONCONSTRUCTIONDOORHM FRAMEEXISTING CMUEMA ANCHORBACKER ROD & SEALANT, EA SIDEGROUT FRAME SOLIDNOTE: FASTEN FRAME THROUGH EXISTING METAL LATH & PLASTER TO STEEL COLUMN ON OPPOSITE ENDEXISTING 4" CMUUL APPROVED EXISTING WALL ANCHORS. DIMPLE FRAME FOR FLUSH BOLT HEADSDOORH.M. FRAME FILLSOLID W/ GROUT3 5/8"4 5/8"TYP2"5/8"J21 3/4"1/2"These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions5/20/2020 10:19:23 AMC:\1-Local Revit Models 2019\19700.00_Cornell Olin Chem Lab 573-580_Arch_R19_central_walkup54.rvt19700.00SDFDoor Schedule &DetailsCWJCREA-601100% ConstructionDocumentsCornell UniversityS.T. Olin Chemistry ResearchWing -Chem Lab 573-580RenovationFacilities & Campus Services -Humphreys Service Building,Ithaca, NY 1485305/22/2020DOOR SCHEDULEDOOR #DOORFRAMEHARDWARELABELTHRESHOLDREMARKSDOOR #LEAFSSIZETYPEMATERIALFINISHGLASSELEVATIONJAMB TYPEMATERIALFINISHWIDTHHEIGHTTHICKFIFTH FLOOR500CA(2)2' - 10"7' - 0"1 3/4"D3HMPT-2FP-2F1J1HMPT-2REFERENCEHARDWARESCHEDULE90 MIN-500CA570A(2)4' - 0"7' - 0"1 3/4"D1HMPREFINFP-2EXISTEXISTE-HMPT-2REFERENCEHARDWARESCHEDULE90 MIN-3570A573(2)4' - 0"7' - 0"1 3/4"D1WDPREFINFP-1EXISTEXISTE-HMPT-2REFERENCEHARDWARESCHEDULE45 MIN-1573575A(1)3' - 0"7' - 0"1 3/4"D4HMPT-2-F1J2HMPT-2REFERENCEHARDWARESCHEDULE--575A580(2)4' - 0"7' - 0"1 3/4"EXISTEXIST-WDEXISTEXISTEXISTEXISTE-HMPT-2REFERENCEHARDWARESCHEDULEEXIST-580580A(2)4' - 6"7' - 0"1 3/4"D2WDPREFINS-1SEE 3/A-601PERSTOREFRONTMFRALUMBLACKANODIZEDREFERENCEHARDWARESCHEDULE-REFERENCEHARDWARESCHEDULE2580A1 1/2" = 1'-0"1Door 573 DetailDoor Elevations1/4" = 1'-0"2Storefront Plan Detail1/4" = 1'-0"3East Storefront Elevation1/4" = 1'-0"4North Storefront ElevationDoor Schedule Remarks+PAIR2' -9"1' -3"+PAIR3' -0"1' -0"+PAIR3' -0"1' -6"+PAIR3' -0"1' -0"Frame ElevationJamb Details(PAIR)NOTE: REFERENCE FLOOR PLAN AND INTERIOR ELEVATIONS FOR ADDITIONAL WINDOW TYPES61 FEFEFEMISCELLANEOUS FINISH REQUIREMENTS TO WALLS, FLOORS & CEILINGS IN AREAS AFFECTED BY DEMO HAVE NOT BEEN TOTALLY INCORPORATED INTO THE ROOM FINISH SCHEDULE. REFER TO DEMOLITION, FLOOR & REFLECTED CEILING PLANS FOR EXTENT OF "CUTTING & PATCHING". PATCHING SHALL BE THE REPAIR WORK REQUIRED TO RESTORE SURFACES TO THE ORIGINAL CONDITION AND/OR MATCHING THE ADJACENT SURFACES.FLOORING TO BE CONTINUOUS THROUGHOUT ROOM, INCLUDING UNDER FIXED CABINETS, EQUIPMENT, ETC. IN THE ROOM FINISH SCHEDULE -IN ANY ROW OR COLUMN "-" or "ETR" INDICATES THERE ARE NO CHANGES OR NEW FINISHES, EXISTING TO REMAINPAINT ALL EXPOSED HVAC, PLUMBING & ELECTRICAL CONSTRUCTION TO MATCH ADJACENT OR BACKGROUND SURFACES UNLESS OTHERWISE NOTED, INCLUDING BUT NOT LIMITED TO STEEL GRILLES, DIFFUSERS, REGISTERS, AND LOUVERS. PAINT ALL VISIBLE FRAMING BEHIND HVAC REGISTER VENTS FLAT BLACK DO NOT PAINT OPERATIONAL COMPONENTS OF SYSTEMS INCLUDING BUT NOT LIMITED TO SPRINKLER HEADS, FIRE, SMOKE, OR HEAT DETECTORS.REFER TO NOTES IN INTERIOR FINISHES & MATERIALS LIST FOR SOFFIT PAINT COLORSPAINTING IS NOT REQUIRED BEHIND FIXED CABINETS.PROVIDE TRANSITION STRIPS BETWEEN DIFFERENT FLOOR MATERIALS AS INDICATED ON SCHEDULE.WHERE TRANSITIONS OCCUR AT DOORWAYS, CENTER TRANSITION BENEATH DOOR.PAINT HOLLOW METAL FRAMES & DOORS UNLESS OTHERWISE INDICATED. FINISH FRAMES & DOORS THE SAME ON BOTH SIDES UNLESS INDICATED AS A SPLIT FINISHALL GYPSUM BOARD CEILINGS TO BE FLAT FINISH UNLESS OTHERWISE NOTEDALL PAINTED VERTICAL SURFACES (WALLS, SOFFITS, COLUMNS, ETC ) TO BE AN EGGSHELL FINISH UNLESS OTHERWISE NOTED.PROVIDE MOISTURE RESISTANT GYP BD AT ALL WALLS AT WET AREAGENERAL NOTES -FINISHESA.B.C.D.E.F.G.H.I.J.K.L.M.N.ROOM FINISH LEGENDSECTION 09 65 00 -RESILIENT FLOORINGLUXURY VINYL FLOORING (LVT)LVT-1MANNINGTON, LUXURY VINYL TILE WITH MICRO BEVEL EDGES, COLLECTION: SELECT PLANK, SIZE: 5" x 48", COLOR: AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE, INSTALLATION: 1/3STAGGERED RUNNING BOND, DIRECTION AS INDICATED ON PLANS (OFFICES)VINYL COMPOSITION TILE (VCT)VCT-1ARMSTRONG, PREMIUM EXCELON TILE STONETEX, COLOR: PEBBLE GRAY 52122 (MATCHED TO CORRIDOR), 1/8" THICK, 12"X12" TILES, INSTALLATION: GRAINING TO RUN AS SHOWN ON FINISH FLOOR PLANS,DO NOT QUARTER TURN TILES(WRITE-UP)SECTION 09 65 13 -RESILIENT BASE AND ACCESSORIESRUBBER BASE (RB)RB-1ROPPE, RUBBER BASE, 4" H, COVE TOE BASE, COLOR: AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGESECTION 09 67 23 -RESINOUS FLOORING RESINOUS FLOOR (RES)RES-1EPOXY RESINOUS FLOORING SYSTEM: SHERWIN WILLIAMS, TRAFFICOTE 105 W/ GP3741 NOVOLAC EPOXY ACID RESISTANT TOP COAT, COLOR: CUSTOM TO MATCH PANTONE: WARM GREY 3 C.(LAB 580A & LAB 573)SECTION 09 51 13 -ACOUSTICAL PANEL CEILINGSACOUSTICAL CEILING TILE (ACT)ACT-1CERTAINTEED PERFORM TILE, FINE FISSURED HHF-154, 24" X 24" REVEL TILE, INCLUDE 9/16" NARROW REVEAL CORNER BEVEL GRID, COLOR: WHITESECTION 09 91 23 -INTERIOR PAINTINGPAINT (PT)-ALL DOORS, FRAMES AND TRIM –SEMI-GLOSS-CEILINGS –FLAT-ALL PAINTED VERTICAL SURFACES (WALLS, SOFFITS, COLUMNS, ETC) TO BE AN EGGSHELL FINISH.-AT EXPOSED CEILING USE DRYFALL PAINT.PT-1BENJAMIN MOORE, COLOR: LINEN WHITE 912(GENERAL)PT-2BENJAMIN MOORE, COLOR: LINEN WHITE,(DOOR & FRAMES, WHERE INDICATED TO BE SPLIT FINISH USE AT DOORS AND FRAME ROOM SIDE)PT-3BENJAMIN MOORE, COLOR: PEBBLE DRIFT, (DOOR & FRAMES, CORRIDOR SIDE)SECTION 10 14 00 -SIGNSPANEL SIGNAGEINTEGRAL ACRYLIC SHEET COLOR:TBD FROM FULL RANGE OF INDUSTRY COLORS RAISED TEXT AND TYPEFACE COLOR:AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGESECTION 12 24 13 –ROLLER WINDOW SHADESWINDOW TREATMENTS (WT)WT-1DRAPER INC. -STYLE: 3G MERMET COMPANY M-SCREEN #8503 -FLEX SHADE MESH SHADE WITH FASCIA, MANUALLY CLUTCH CONTROLLED, 3% OPENNESS, COLOR: 002020 WHITE/LINEN, HARDWARE COLOR: IVORY (EXTERIOR WINDOWS AT LABS AND OFFICES)SECTION 12 35 53 -LABORATORY CASEWORK SOLID PHENOLIC COUNTERTOPSSP-1TRESPA TOP LAB PLUS, BLACK T90.0.0 CRYSTAL MATTE, S, STANDARD THICKNESS, NO BUILT UP EDGESECTION 12 36 23.13 –PLASTIC-LAMINATE-CLAD COUNTERTOPSPLASTIC LAMINATE COUNTERTOPS (PLAM)PLAM-1NEVAMAR ARP, COLOR: MR62T CHARCOAL MATRIX TEXTURED(WRITE-UP COUNTERTOP)1.WT-1 AT EXTERIOR WINDOWSROOM FINISH SCHEDULE REMARKSLAB572LAB580AWRITE-UP580P.I. OFFICE582AOFFICE582STAIR500SBMECH500UDWOMEN'S500TBCORRIDOR500CALAB571LAB573LVT-1EXIST.VCTLVT-1VCT-1VCT-1RES-1EXIST.VCTRES-1RES-1EXIST.VCTRES-1EXIST.VCTFLASH LUXURY VINYL TILE FOR FLUSH TRANSITION BETWEEN FLOORING MATERIALS. NOT TO EXCEED 1/8" PER FOOT.VCT-1EXIST.VCTLVT-1EXIST.VCTFLASH LUXURY VINYL TILE FOR FLUSH TRANSITION BETWEEN FLOORING MATERIALS. NOT TO EXCEED 1/8" PER FOOT.FLASH LUXURY VINYL TILE FOR FLUSH TRANSITION BETWEEN FLOORING MATERIALS. NOT TO EXCEED 1/8" PER FOOT.FLOORING TO EXTEND INTO PIPE CHASEREFERENCE DOOR HARDWARE SCHEDULE FOR THRESHOLDFLOOR FINISH LEGENDLUXURY VINYL TILE -LVT-1RESINOUS FLOORING -RES-1VINYL COMPOSITION TILE -VCT-1FLOORING DIRECTIONThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions5/20/2020 10:19:30 AMC:\1-Local Revit Models 2019\19700.00_Cornell Olin Chem Lab 573-580_Arch_R19_central_walkup54.rvt19700.00SDFRoom Finish Plans,Schedule & LegendCWJCRE/CNGA-602100% ConstructionDocumentsCornell UniversityS.T. Olin Chemistry ResearchWing -Chem Lab 573-580RenovationFacilities & Campus Services -Humphreys Service Building,Ithaca, NY 1485305/22/2020ROOM FINISH SCHEDULEROOM NUMBERROOM NAMEFLOORBASEWALLCEILINGFINISHREMARKSROOM NUMBERMATERIAL/ FINISHMATERIAL/ FINISHNORTHSOUTHEASTWESTMATERIALFINISHMATERIALFINISHMATERIALFINISHMATERIALFINISHFIFTH FLOOR573LABRES-1RB-1ETR CMU/ETR GWBPT-1ETR CMUPT-1ETR CMUPT-1ETR CMUPT-1ACT-1/PT-11573580WRITE-UPVCT-1RB-1ETR CMUPT-1ETR CMUPT-1ETR CMU/ETR GWBPT-1GWBPT-1ACT-1/PT-11580580ALABRES-1RB-1ETR CMUPT-1ETR GWB/ETR CMUPT-1GWBPT-1ETR CMUPT-1ACT-1/PT-11580A582OFFICELVT-1RB-1ETR CMUPT-1ETR CMUPT-1ETR CMUPT-1ETR CMUPT-1ETR1582582AP.I. OFFICELVT-1RB-1ETR CMUPT-1ETR CMUPT-1ETR CMUPT-1ETR CMUPT-1ACT-11582A1/4" = 1'-0"1Partial Fifth Floor Finish Plan M S SP 1. ANY PHYSICAL INSTALLATION MODIFICATIONS DUE TO FIELD CONDITIONS SHALL BE RESOLVED BY THE MECHANICAL CONTRACTOR IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE MECHANICAL ENGINEER. 2. THIS CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS STEEL AND SUPPORTS TO SUSPEND DUCTWORK AND EQUIPMENT. 3. ALL EQUIPMENT SHALL BE INSTALLED WITH VIBRATION ISOLATORS. 4. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT TO ENSURE A COMPLETE SYSTEM. 5. THIS CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES. 6. THE MECHANICAL CONTRACTOR SHALL SEAL ALL HIS RESPECTIVE WALL AND ROOF PENETRATIONS. 7. THE MECHANICAL CONTRACTOR SHALL PAY FOR ALL FEES AND PERMITS AS NECESSARY TO COMPLETE THE INSTALLATION. 8. THE MECHANICAL CONTRACTOR SHALL PROVIDE MANUAL AIR VENTS AT ALL HIGH POINTS IN HYDRONIC SYSTEMS AND AT EACH UNIT TO FACILITATE MANUAL VENTING. PROVIDE 3/4" HOSE END DRAINS, (WITH CAP & CHAIN), AT ALL LOW POINTS TO FACILITATE DRAINAGE. 9. ALL REFRIGERATION PIPING SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS, ALL PIPE SIZES SHALL BE PER MANUFACTURER'S REQUIREMENTS BASED ON PROPOSED PIPE ROUTING AND EQUIPMENT LOCATIONS. 10. ALL REFRIGERANT PIPING SHALL BE PITCHED A MINIMUM OF 1/2" IN 10'-0" IN THE DIRECTION OF THE REFRIGERANT FLOW. 11. ALL PIPE PENETRATIONS THROUGH CHASES, WALLS, OR FLOORS WHICH ARE FIRE- RATED SHALL BE PROPERLY SEALED TO MAINTAIN RATING. 12. ALL DUCTS THAT PENETRATE CHASES, WALLS, OR FLOORS WHICH ARE FIRE-RATED SHALL BE INSTALLED WITH FIRE DAMPERS IN ACCORDANCE WITH NFPA 90A. THIS APPLIES EVEN IF THEY ARE NOT SPECIFICALLY SHOWN ON THE DRAWINGS. 13. COORDINATION DRAWINGS AT NOT LESS THAN A 1/4" PER FOOT. SHOWING THE PROPOSED EQUIPMENT ARE REQUIRED FOR ALL AREAS AND SHALL BE REVIEWED BY ALL TRADES PRIOR TO SUBMISSION TO THE PROFESSIONAL. 14. ALL DUCTWORK, EQUIPMENT, PIPING, ETC. SHALL BE INSTALLED ABOVE THE FINISHED CEILING UNLESS SPECIFICALLY NOTED OTHERWISE. MECHANICAL NOTES 1. ALL DUCTWORK SIZES NOTED ARE FREE AREA SIZES. 2. TURNING VANES SHALL BE PROVIDED IN ALL RECTANGULAR DUCT ELBOWS. 3. BALANCING DAMPERS SHALL BE PROVIDED AT ALL DUCT BRANCHES. 4. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING INSTALLATION OF AIR DEVICES WITHIN THE CEILING GRID WITH LIGHTING FIXTURES, SPRINKLER HEADS, ETC. 5. LENGTH OF FLEXIBLE DUCT BRANCHES SHALL NOT EXCEED 3'-0" MAXIMUM. ADDITIONAL LENGTH FOR INDIVIDUAL CONNECTIONS SHALL BE RIGID ROUND SHEET METAL DUCTWORK. 6. FLEXIBLE DUCT SHALL NOT BE ACCEPTABLE FOR EXHAUST FAN INSTALLATIONS. 7. DUCTWORK SIZES ARE DEFINITE AND LOCATIONS ARE APPROXIMATE. MECHANICAL CONTRACTOR CAN MAKE MINOR DUCTWORK SIZE REVISIONS TO ACCOMMODATE AVAILABLE SPACE. SIZING SHALL BE BASED ON A MAXIMUM OF .08" PRESSURE LOSS PER 100' (STATIC PRESSURE), AND A MAXIMUM 1100 FPM AIR VELOCITY. DUCTWORK SYSTEMS SHALL BE SIZED BASED ON HVAC FAN STATIC PRESSURE AND FAN DUTY POINTS. DUCTWORK NOTES OUTDOOR AMBIENT CONDITIONS: WINTER = -5°F DB SUMMER = 88° DB, 73°F WB INDOOR CONDITIONS: HEATING = 70°F DB COOLING = 75°F DB, 63°F DB CODES: 2020 INTERNATIONAL MECHANICAL CODE 2020 INTERNATIONAL ENERGY CONSERVATION CONSTRUCTION CODE 2020 NEW YORK STATE UNIFORM CODE SUPPLEMENT DESIGN PARAMETERS 1. CONTRACTORS ARE URGED TO INSPECT THE SITE BEFORE SUBMITTING A BID PROPOSAL TO ENSURE KNOWLEDGE OF PROJECT REQUIREMENTS AND SITE CONDITIONS. IF NO CLARIFICATION IS REQUESTED, IT WILL BE CONSIDERED THAT THE CONTRACTORS ARE IN FULL UNDERSTANDING OF PROJECT REQUIREMENTS. 2. PROVIDE LABOR, SUPERVISION, EQUIPMENT, MATERIALS, AND SERVICES REQUIRED FOR THE COMPLETE INSTALLATION OF THIS WORK IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE, AND LOCAL CODES, AUTHORITIES HAVING JURISDICTION, AND STANDARDS INCLUDING BUT NOT LIMITED TO THE LATEST ADOPTED VERSIONS OF ASHRAE, IBC, IPC, IFGC, NEC, NFPA, AND SMACNA. 3. NOTHING CONTAINED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS SHALL BE CONSTRUED TO BE IN CONFLICT WITH ANY STATE OR LOCAL CODES, ORDINANCES OR REGULATIONS. 4. THE USE OF THE WORD "PROVIDE" SHALL MEAN TO FURNISH, INSTALL AND CONNECT, READY TO USE. 5. THE USE OF THE WORD "FURNISH" SHALL MEAN TO PROCURE AND DELIVER TO THE SITE. 6. THE USE OF THE WORD "INSTALL" SHALL MEAN TO PHYSICALLY PLACE INTO SERVICE AND CONNECT, READY TO USE. 7. EQUIPMENT AND MATERIALS SHALL BE INSTALLED BY SKILLED TRADESMEN, FAMILIAR WITH THE COMPONENTS TO BE INSTALLED, AND IN ACCORDANCE WITH BEST PRACTICES OF THE INDUSTRY. 8. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE ONLY THE GENERAL ARRANGEMENT OF PIPING, DUCTWORK, CONDUITS, EQUIPMENT, ETC. ITEMS OF WORK OR EQUIPMENT SHOWN ON THE DRAWINGS ONLY, OR CALLED FOR IN THE SPECIFICATIONS ONLY, SHALL BE FURNISHED AND INSTALLED IN THE SAME MANNER AS IF THEY APPEARED ON BOTH DRAWINGS AND THE SPECIFICATIONS. 9. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS, AND ACCESSORIES THAT MAY BE REQUIRED. THIS CONTRACTOR SHALL CAREFULLY EXAMINE THE ARCHITECTURAL, STRUCTURAL, HEATING, VENTILATING AND AIR-CONDITIONING, ELECTRICAL, PLUMBING, AND OTHER PROJECT DOCUMENTS AS MAY BE NECESSARY FOR PROPER OPERATION OR INSTALLATION AND SHALL PROVIDE OFFSETS, FITTINGS, AND ACCESSORIES TO MEET PROJECT CONDITIONS. 10. DISCREPANCIES BETWEEN DRAWINGS OR BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE REPORTED TO PROFESSIONAL IN WRITING. OBTAIN WRITTEN INSTRUCTIONS FROM PROFESSIONAL AS TO THE MANNER IN WHICH TO PROCEED. NO DEPARTURES FROM THE PROJECT DOCUMENTS SHALL BE MADE WITHOUT PRIOR WRITTEN ACCEPTANCE BY THE PROFESSIONAL. ALL PHYSICAL ATTRIBUTES OF EQUIPMENT AND DEVICES ARE BASED ON THOSE MANUFACTURERS LISTED IN THE SPECIFICATIONS AND/OR THE EQUIPMENT SCHEDULES. THE RESPECTIVE CONTRACTORS ARE RESPONSIBLE FOR ALL CHANGES BROUGHT ABOUT BY THE USE OF ITEMS BY OTHER MANUFACTURERS IF THOSE ITEMS DO NOT MATCH THE PHYSICAL ATTRIBUTES OF THE MANUFACTURERS LISTED. 11. THE FIRE RESISTANCE RATINGS OF ALL WALLS, PARTITIONS, FLOORS, STEEL, ETC. SHALL BE MAINTAINED. THE APPLICATION OF PRODUCTS AND/OR DEVICES INTENDED TO MAINTAIN THESE RATINGS SHALL BE SUBMITTED FOR REVIEW AND INSTALLED PER MANUFACTURER'S INSTRUCTIONS. 12. IN ORDER TO AVOID DELAY IN THE PROJECT SCHEDULE, AND THE POSSIBLE INSTALLATION OF NON-SPECIFIED MATERIALS, THE CONTRACTOR IS RESPONSIBLE FOR ORDERING ALL PRODUCTS IN A TIMELY FASHION. IF A DELAY OCCURS DUE TO NEGLIGENCE ON PART OF THE CONTRACTOR, ANY FINANCIAL BURDEN ENCOUNTERED WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 13. DIMENSIONS, CLEARANCES, AND LOCATIONS OF EQUIPMENT AND MATERIALS SHALL BE FIELD VERIFIED PRIOR TO ORDERING, PROCURING AND FURNISHING SAME. 14. NO EXTRA COMPENSATION OR CHARGES WILL BE ACCEPTED DUE TO DIFFERENCES BETWEEN THE ACTUAL MEASUREMENTS AND THOSE INDICATED ON THE PLAN. THOROUGHLY COORDINATE WORK WITH SITE CONDITIONS AND OTHER TRADES, DETERMINE EXACT ROUTE AND LOCATION OF EACH DUCT, PIPE, CONDUIT, ETC. BEFORE FABRICATION AND INSTALLATION. 15. THE CONTRACTOR SHALL PROVIDE AND INSTALL ACCESS PANELS, WHETHER INDICATED ON THE CONTRACT DOCUMENTS OR NOT, WHERE REQUIRED TO PROVIDE ACCESS TO THEIR INSTALLATIONS. ACCESS PANELS SHALL MATCH THE FIRE RESISTANCE RATING OF THE PARTITION THAT THEY ARE BEING INSTALLED. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL ACCESS PANELS WITH THE ARCHITECT AND WITH OTHER TRADES TO AVOID DUPLICATION. 16. INSTALL WORK SUBSTANTIALLY AS INDICATED. VERIFY LOCATIONS AND ELEVATIONS ON JOB SITE. DO NOT DIRECTLY SCALE DRAWINGS. MAKE NECESSARY CHANGES IN ELEVATION, FITTINGS, OR OFFSETS TO ACCOMMODATE OBSTACLES OR INTERFERENCES. 17. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR DAMAGE TO THE BUILDING, PIPING OR EQUIPMENT THAT IS THE RESULT OF WORK FOR INSTALLATION OF THIS CONTRACT. 18. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR PATCH AND REPAIR OF ALL SURFACES TO MATCH EXISTING MATERIALS AND ADJACENT FINISHES ASSOCIATED WITH INSTALLATION/REMOVAL OF THIS WORK UNLESS SPECIFICALLY NOTED OTHERWISE. 19. WORK SHALL BE COMPLETED TO MAINTAIN ALL NECESSARY AND REQUIRED CLEARANCES, ACCESSES, AND OPENINGS, SUCH THAT FULL FUNCTIONALITY, PROPER OPERATION, AND REPAIR AND MAINTENANCE ARE ENSURED. 20. WHERE DEVICE HEIGHT OF 48" OCCURS AT POINT OF CHANGE OF FINISH, THE DEVICE SHALL BE LOWERED TO OCCUR IN ONE FINISH. 21. WHERE DEVICE OCCURS IN BRICK, TILE, OR BLOCK WALLS, THEY SHALL BE MOUNTED AT A VERTICAL MASONRY JOINT & IN THE BOTTOM HORIZONTAL JOINT, CLOSEST TO THE MOUNTING HEIGHT. 22. UNLESS OTHERWISE NOTED, ALL MOUNTING HEIGHT DIMENSIONS LISTED ARE TO THE CENTER LINE OF THE BOX OR DEVICE. 23. NOT ALL ABBREVIATIONS & SYMBOLS MAY APPLY TO THIS PROJECT. 24. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE LABELED AND LISTED BY A CERTIFIED TESTING LABORATORY OR AGENCY. 25. DRAWINGS REPRESENT THE SCOPE OF WORK IN GENERAL ARRANGEMENT FORM AND ARE INTENDED TO SHOW GENERAL ROUTING AND REQUIRED SIZES/CAPACITIES OF SYSTEM COMPONENTS. GENERAL NOTES AB ABOVE AD ACCESS DOOR OR AREA DRAIN ADP APPARATUS DEW POINT AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AFUE ANNUAL FUEL UTILIZATION EFFICIENCY AGA AMERICAN GAS ASSOCIATION AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT AMB AMBIENT AMP AMPERES ANSI AMERICAN NATIONAL STANDARDS INSTITUTE APD AIR PRESSURE DROP ASHRAE AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS AST ABOVE GROUND STORAGE TANK ATC AUTOMATIC TEMPERATURE CONTROL ATCC AUTOMATIC TEMPERATURE CONTROLS CONTRACTOR AVG AVERAGE AWG AMERICAN WIRE GAGE AWT AVERAGE WATER TEMPERATURE AWWA AMERICAN WATER WORKS ASSOCIATION BAS BUILDING AUTOMATION SYSTEM BD BALANCING DAMPER BF BLIND FLANGE BS BIRDSCREEN BDD BACKDRAFT DAMPER BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNITS PER HOUR BHP BRAKE HORSEPOWER CA COMMISSIONING AGENT OR AUTHORITY CCO CEILING CLEANOUT CFM CUBIC FEET PER MINUTE CI CAST IRON CLG CEILING CONN CONNECTION CONT CONTINUATION CONV CONVECTOR COP COEFFICIENT OF PERFORMANCE CU CONDENSING UNIT CU FT CUBIC FEET CU IN CUBIC INCH CW COLD WATER °C DEGREES CELSIUS °F DEGREES FAHRENHEIT ø DIAMETER D DRYER, APPLIANCE DB DRY BULB DBP DOMESTIC BOOSTER PUMP DF DRINKING FOUNTAIN DHRP DOMESTIC HOT WATER RETURN PUMP DIR DIRECT DN DOWN DP DOMESTIC PUMP DR DRAIN DWG DRAWING DX DIRECT EXPANSION (E)EXISTING E/A EXHAUST AIR EAT ENTERING AIR TEMPERATURE EC ELECTRICAL CONTRACTOR EER ENERGY EFFICIENCY RATIO EFF EFFICIENCY ELEV ELEVATION ESP EXTERNAL STATIC PRESSURE ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EWT ENTERING WATER TEMPERATURE EXT. F&B EXTERNAL FACE & BYPASS EXP EXPANSION FA FREE AREA FAS FIRE ALARM SYSTEM FC FLEXIBLE CONNECTION FD FLOOR DRAIN OR FIRE DAMPER FLA FULL LOAD AMPERES FLR FLOOR FMS FACILITY MANAGEMENT SYSTEM FOS FUEL OIL SUPPLY FOR FUEL OIL RETURN FPC FIRE PROTECTION CONTRACTOR FPI FINS PER INCH FPM FEET PER MINUTE FPS FIRE PROTECTION SYSTEM FS FLOOR SINK FT FEET OR FOOT FT LB FOOT POUND GA GAUGE GAL GALLONS GALV GALVANIZED GC GENERAL CONTRACTOR GI GREASE INTERCEPTOR GPH GALLONS PER HOUR GPM GALLONS PER MINUTE GRD GRILLES, REGISTERS, & DIFFUSERS GWH GAS WATER HEATER MECHANICAL ABBREVIATIONS H HUMIDITY HC HEATING CONTRACTOR HD HEAD HGT HEIGHT HP HORSEPOWER HR HOUR(S) HUM HUMIDIFIER HW HOT WATER HZ HERTZ ID INSIDE DIAMETER IN WC INCHES WATER COLUMN INV INVERT IN WG INCHES WATER GAGE IW INDIRECT WASTE JS JANITORS SINK KW KILOWATT KWH KILOWATT HOUR LxWxD LENGTH x WIDTH x DEPTH LAT LEAVING AIR TEMPERATURE L LAVATORY LAV LAVATORY LF LINEAR FEET LD LINEAR DIFFUSER LBS POUNDS LRA LOCKED ROTOR AMPERES LWT LEAVING WATER TEMPERATURE M/A MIXED AIR MAX MAXIMUM MBH 1,000 BTUH MMBH 1,000,000 BTUH MC MECHANICAL CONTRACTOR MD MOTORIZED DAMPER MFR MANUFACTURER MIN MINIMUM MOD MOTOR OPERATED DAMPER MR MOP RECEPTOR MTD MOUNTED N/A NOT APPLICABLE NC NORMALLY CLOSED NIC NOT IN CONTRACT NG NATURAL GAS NO NORMALLY OPEN NP NON-POTABLE NTS NOT TO SCALE O/A OUTSIDE AIR OD OUTSIDE DIAMETER OR OVERFLOW DRAIN OED OPEN END DUCT OZ OUNCE P PUMP PC PLUMBING CONTRACTOR PD PRESSURE DROP PH PHASE PPM PARTS PER MILLION PRV PRESSURE REDUCING VALVE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE PT PRESSURE/TEMPERATURE TEST PORT PVC POLYVINYLCHLORIDE R/A RETURN AIR RD ROOF DRAIN REQ'D REQUIRED RH RELATIVE HUMIDITY RLA RUNNING LOAD AMPS RPM REVOLUTIONS PER MINUTE RX REMOVE EXISTING S SINK S/A SUPPLY AIR SATC SUSPENDED ACOUSTICAL TILE CEILING SF SQUARE FEET S/FD SMOKE/FIRE DAMPER SH SHOWER SI SOLIDS INTERCEPTOR SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION SP STATIC PRESSURE T TEMPERATURE TBR TO BE REMOVED TCC TEMPERATURE CONTROL CONTRACTOR TD TRENCH DRAIN THA TOTAL HEAT ADDED TP TEST PORT TSP TOTAL STATIC PRESSURE TSTAT THERMOSTAT TT TEMPERATURE TRANSMITTER TYP TYPICAL UNO UNLESS NOTED OTHERWISE UST UNDERGROUND STORAGE TANK UR URINAL V VENT VAV VARIABLE AIR VOLUME VBF VENT BELOW FLOOR VRV VARIABLE REFRIGERANT VOLUME VTR VENT THROUGH ROOF W WASHER, APPLIANCE OR WASTE WB WET BULB WC WATER CLOSET WPD WATER PRESSURE DROP HVAC SYMBOL LEGEND CONNECT TO EXISTING 1 A101 REFERENCE DRAWING 1 A101 DETAIL NUMBER DIRECTION INDICATOR DISCONNECT EXISTING SUPPLY AIRFLOW RETURN/ EXHAUST AIRFLOW DETAIL DESIGNATION SECTION DESIGNATION DUCT SECTION, EXHAUST DUCT SECTION, RETURN OR RELIEF AIR DUCT SECTION, SUPPLY OR OUTDOOR AIR REFERENCE DRAWING DETAIL NUMBER SUPPLY AIR DEVICE RETURN/ EXHAUST AIR DEVICE RECTANGULAR ELBOW, MITERED WITH TURNING VANES VOLUME DAMPER MOTOR OPERATED DAMPER BACKDRAFT DAMPER FIRE DAMPER, PROVIDE ACCESS DOOR WHERE SHOWN FIRE & SMOKE DAMPER, PROVIDE ACCESS DOOR WHERE SHOWN SMOKE DAMPER, PROVIDE ACCESS DOOR WHERE SHOWN DUCT SMOKE DETECTOR DUCT MOUNTED SENSOR (SP-STATIC PRESSURE, DP-STATIC DIFFERENTIAL PRESSURE, T-TEMPERATURE) HUMIDISTAT THERMOSTAT COMBINATION THERMOSTAT/ HUMIDISTAT CO2 SENSOR OCCUPANCY SENSOR CHANGE OF DIRECTION, RISE (R), DROP (D) DUCT ACCESS DOOR FLEX DUCT DUCT TRANSITIONS, RECTANGULAR 1t T H CO OC T H R D DUCT TRANSITION, RECTANGULAR TO ROUND 24x18 DUCT, WIDTH x HEIGHT (E)24x18 EXISTING DUCT TO REMAIN, WIDTH x HEIGHT EXISTING DUCT TO BE REMOVED, WIDTH x HEIGHT24x18 DUCT, ROUND DIAMETER SIZE24ø AD VD 1. THE DEMOLITION PLANS AND NOTES HAVE BEEN PREPARED TO ASSIST THE CONTRACTORS IN IDENTIFYING THE AREAS AND ITEMS OF DEMOLITION AND RENOVATION ASSOCIATED WITH THIS PROJECT. THE INFORMATION PROVIDED IS NOT MEANT TO BE ALL-INCLUSIVE IN TERMS OF LISTING EACH AND EVERY SPECIFIC TASK TO BE PERFORMED. EACH CONTRACTOR WILL THOROUGHLY EXAMINE ALL CONTRACT DOCUMENTS PRIOR TO PERFORMING ANY WORK. 2. DEMOLITION WORK INCLUDES, BUT IS NOT LIMITED TO, THE ITEMS INDICATED ON THE DEMOLITION DRAWINGS AND DESCRIBED IN THE DEMOLITION NOTES. THE EXTENT OF THE DEMOLITION WORK WILL INCLUDE ALL WORK REQUIRED TO COMPLETE THE PROJECT AND ENSURE WHETHER OR NOT THE WORK IS INDICATED ON THE DRAWINGS. 3. EACH CONTRACTOR SHALL THOROUGHLY EXAMINE AND VERIFY ALL EXISTING CONDITIONS BEFORE PERFORMING ANY WORK AND IMMEDIATELY NOTIFY THE ARCHITECT, IN WRITING, OF ANY DISCREPANCIES WITH THE DRAWINGS. 4. ANY WORK PERFORMED AS PART OF THIS CONTRACT REQUIRING OR ALTERATION WILL BE THE RESPONSIBILITY OF THE RESPECTIVE CONTRACTOR. 5. ALL ITEMS NOTED TO BE REMOVED TO BE DISPOSED OF OFF-SITE BY RESPECTIVE CONTRACTORS, UNLESS NOTED OTHERWISE. WHERE INDICATED ON THE DRAWINGS AND/OR IN THE NOTES AS SALVAGE AND DELIVER TO OWNER. THE CONTRACTOR WILL CAREFULLY REMOVE INDICATED ITEMS AND STORE THEM WHERE DIRECTED BY THE OWNER. 6. THE OWNER HAS THE OPTION TO RETAIN POSSESSION OF ANY REMOVED MATERIALS OR EQUIPMENT. ALL SUCH ITEMS SHALL BE CAREFULLY REMOVED AND STORED AT THE SITE BY THE CONTRACTOR WHERE DIRECTED BY THE OWNER. ANY MATERIALS OR EQUIPMENT NOT RETAINED BY THE OWNER WILL BECOME THE PROPERTY OF THE CONTRACTOR AND PROMPTLY REMOVED FROM SITE. 7. ANY CONTRACTOR REMOVING OR MODIFYING MATERIAL CONTAINING ASBESTOS OR SUSPECTED OF CONTAINING ASBESTOS WILL NOTIFY THE OWNER AT ONCE AND STOP REMOVAL. IDENTIFICATION AND/OR REMOVAL OF ASBESTOS CONTAINING MATERIAL WILL BE THE RESPONSIBILITY OF THE OWNER. 8. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, TECHNOLOGY AND PLUMBING DRAWINGS FOR DEMOLITION WORK BY RESPECTIVE CONTRACTORS. EACH CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION ASSOCIATED WITH HIS CONTRACT AND SCOPE OF WORK. EACH CONTRACTOR IS RESPONSIBLE TO PATCH AND/OR REPAIR ANY AND ALL CONSTRUCTION AFFECTED BY HIS DEMOLITION. THE EXTENT OF PATCH AND REPAIR SHALL BE AS REQUIRED TO RECEIVE THE SCHEDULED NEW WORK. ALL CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK WITH OTHER CONTRACTORS BEFORE PERFORMING ANY WORK. 9. ALL PATCH AND REPAIR WORK SHALL BE PERFORMED USING MATERIALS THAT MATCH THE EXISTING ADJACENT CONSTRUCTION. WHERE PATCHING EXISTING MASONRY WALLS OR INFILLING BETWEEN WALLS WITH MASONRY TO MATCH EXISTING, "TOOTH-IN" NEW MASONRY TO EXISTING. 10. EACH CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING CONSTRUCTION SCHEDULED TO REMAIN. EACH CONTRACTOR IS RESPONSIBLE TO PATCH AND/OR REPAIR ANY AND ALL CONSTRUCTION AFFECTED BY THEIR DEMOLITION. EACH CONTRACTOR SHALL PATCH (SUBSTRATE AND FINISHED SURFACES) ANY EXISTING FINISHES AFFECTED BY THEIR RESPECTIVE WORK. 11. EXISTING CONDITIONS INDICATED ARE OBTAINED FROM AVAILABLE SOURCES (EXISTING DRAWINGS, FIELD SURVEYS, ETC.) AND ARE NOT GUARANTEED TO BE TRUE AND EXACT. CONTRACTOR(S) SHALL FIELD VERIFY EXISTING CONDITIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE AFFECTED PORTION OF THE WORK. 12. REMOVAL IN ITS ENTIRETY INCLUDES HANGERS, ELECTRICAL, CONTROLS, ETC., TO LEAVE A LIKE NEW OR MATCHING EXISTING CONDITION. GENERAL DEMOLITION NOTES SOLENOID VALVE FLOW METER BALL VALVE REFRIGERATION - HOT GAS HASHMARK FOR PIPING BELOW SLAB DEMO (DASHED-HEAVY LINE) EXISTING (LIGHT SOLID LINE) CHILLED WATER SUPPLY CHILLED WATER RETURN HEATING WATER SUPPLY HEATING WATER RETURN STEAM WET CONDENSATE RETURN CONDENSATE DRAIN (AIR CONDITIONING) PUMPED CONDENSATE FUEL OIL SUPPLY GLYCOL CHILLED SUPPLY REFRIGERATION - HIGH PRESSURE LIQUID REFRIGERATION - HIGH PRESSURE SUCTION GLYCOL HOT WATER SUPPLY GLYCOL HOT WATER RETURN FUEL OIL RETURN CONDENSER WATER SUPPLY CONDENSER WATER RETURN GLYCOL CHILLED RETURN (E) CWS CWR HWS HWR STM WCR C PC FOS FOR CS CR GCHS GCHR GHS GHR RL RS HG BDD TEMPERATURE SENSORS D P These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 1:58:34 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 JB HVAC SYMBOLS, NOTES & ABBREVIATIONS AST CEV M-000 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 D D D D D D D D D 1 12 3 4 5 2 3 7 6 6 6 7 4 5 3 D D 2 D D VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 1:58:34 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 JB HVAC DEMOLITION AST CEV M-101 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020NORTH1/4" = 1'-0" 1 HVAC - DEMO KEYED NOTES: 1. EXISTING FIN TUBE RADIATION PERIMETER HEATING SHALL REMAIN “AS-IS”. 2. DISCONNECT AND REMOVE EXISTING SUPPLY AIR VAV BOX, ASSOCIATED SUPPLY AIR DUCT, DIFFUSERS, CONTROLS, HANGERS, SUPPORTS AND ACCESSORIES. PREPARE DUCT FOR CONNECTION TO NEW WORK. 3. DISCONNECT AND REMOVE HOT WATER SUPPLY AND RETURN WATER LINES TO POINT INDICATED ON PLAN. DISCONNECT AND REMOVE ALL VALVES, HANGERS, SUPPORTS AND ACCESSORIES. PREPARE PIPE FOR CONNECTION TO NEW WORK. 4. DISCONNECT AND REMOVE SOLVENT STORAGE CABINET EXHAUST SYSTEM. DISCONNECT AND REMOVE ALL VALVES, FITTINGS, HANGERS AND ACCESSORIES. FIELD VERIFY EXACT ROUTING. 5. DISCONNECT AND REMOVE FUME HOOD EXHAUST DUCT TO POINT INDICATED ON PLAN. COORDINATE WITH UNIVERSITY HAZMAT FOR PROPER DECONTAMINATION PROCEDURE. 6. DISCONNECT AND REMOVE SUPPLY AIR DIFFUSER PREPARE DUCT FOR CONNECTION TO NEW DIFFUSER. 7. DISCONNECT AND REMOVE RETURN AIR GRILLE. X GENERAL NOTES: 1. EXISTING DUCTWORK, PIPING, AND EQUIPMENT ARE SHOWN ON THIS DRAWING FOR REFERENCE ONLY. EXACT LOCATIONS AND CONFIGURATIONS MUST BE VERIFIED BY THE CONTRACTOR. FEFEFE 1234567891011121314 A B C D E 515 SF LAB 580A 218 SF WRITE-UP 580 53 SF WOMEN 500TB 63 SF MECH 500UD STAIR 500SE CORRIDOR 500CA 342 SF LAB 573 712 SF LAB 575 127 SF OFFICE 582 278 SF OFFICE 582A PERFORATED METAL DUCT P VAV-582A (EXIST) PERFORATED METAL DUCT P P P T T T T VD SAV-2 4"⌀DOWN TO ROTOVAP EXHAUST ARM (2) 5"⌀DOWN IN METAL CHASE TO SOLVENT CABINETS & VACUUM PUMPS BELOW COUNTER PROVIDE (2) 2" CONNECTIONS FOR SOLVENT CABINETS & (1) 4" CONNECTION FOR VAC PUMP, ON EACH 5" DROP, WITH VOLUME DAMPERS 3"⌀DROP INSIDE 4" HOOD CHASE, DOWN TO SOLVENT STORAGE CABINET AND VAC PUMP BELOW HOOD. (TYP. 2) 4"⌀DOWN TO OVEN EXHAUST CONNECT TO EXISTING EXHAUST AIR RISER 3"⌀DOWN TO FLAMMABLE CABINET 12x8 8ø 8ø 10ø P VAV-582 (EXIST) 8ø P 8ø S-1 200 8ø S-1 200 8ø S-1 200 9ø 7ø10ø 8ø S-1 150 8ø 21/12 25/16 15/1227/1834/18 18/1215/1231/1213x11 13x11 40/2044/20 18/1224x624x6P CAV-3 EAV-1 EAV-2 EAV-3 EAV-4 EAV-5 CAV-1 10ø 8ø 6"⌀DOWN TO VAC PUMP CABINET & SOLVENT CABINET UNDER HOOD 16ø 18/12 18/12 20ø P P P EAV-8 CAV-2 EAV-6 EAV-7 4ø 10ø 16ø 10ø 6ø 4ø 8ø 8ø 20ø P P P 3/4" HWR 3/4" HWS 10"⌀DOWN TO FUME HOOD 10"⌀DOWN TO FUME HOOD 10"⌀DOWN TO FUME HOOD 10"⌀DOWN TO FUME HOOD 3/4" HWS 3/4" HWR P P 3/4" HWS 3/4" HWR P TG 8ø R-1 TG 24x24 R-1 TG 12x12 R-1 12x12 R-2 250 12x12 R-2 250 TG 12x8 R-1 SAV-1 RH-1 RH-2 IN NITROGEN STORAGE CLOSET PROVIDE OXYGEN DEFICIENCY MONITORING SYSTEM AND TIE ALARM INTO EXISTING BUILDING MANAGEMENT SYSTEM. 44/20 18/12P P 16ø 16ø PROVIDE NEW FD AT 2H WALL 9ø6ø 6øLOCATE POINTS OF CONNECTION IN FIELD 5 M-501 3ø 2ø 3ø 3ø 2ø 10ø10ø3ø 6ø6ø 18ø 20ø 10ø20ø 3ø3ø 2ø 3ø 3"⌀DROP TO (2) STACKED 2" CONNECTION TO SOLVENT STORAGE 3"⌀DROP, 100 CFM TO VENTED VAC PUMP 3ø 8ø8ø (2) STACKED 2" CONNECTIONS TO SOLVENT STORAGE 3ø 3" CONNECTIONS TO VENTED VAC PUMP (2) STACKED 2" CONNECTIONS TO SOLVENT STORAGE 3"⌀DROP, TO (2) 2" VENTED SOLVENT STORAGE CABINET (TYP 2) 4 M-501 16ø SOFFIT EDGE 18ø STAINLESS STEEL EXHAUST SYSTEM VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 1:58:35 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 JB HVAC NEW WORK AST CEV M-102 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020NORTH1/4" = 1'-0" 1 HVAC - NEW WORK SUPPLY AIR RETURN / EXHAUST AIR BRANCH DUCT MAIN DUCT TAPERED CONNECTION 45deg ANGLE OR CONICAL CONNECTION (IF ROUND) VOLUME DAMPER CEILING PLAN VIEW ELEVATION VIEW LINED DUCTWORK UP TO 2'-0" FROM RETURN GRILLE 2'-0" LINED DUCTWORK UP TO 2'-0" FROM RETURN GRILLE 2'-0" VOLUME DAMPER FLEX DUCT CONNECTION 3'-0" LENGTH MAX EQUALIZING GRID CEILING ROUND OR SQUARE DIFFUSER ACCESS DOOR TO VOLUME DAMPER IN HARD CEILING AREAS ONLY. UNISTRUT THREADED HANGER RODHANGER STRAP NOTE: SIZE AND RATING OF HANGERS AND SUPPORTS SHALL BE PER LATEST "SMACNA" STANDARDS. DUCT OVER 60" DUCT 60" MAX 1" MIN. NOTES: 1. BOX SENSOR SHALL BE ORIENTED IN SAME PLANE AS ELBOW AND BE WITHIN 10' OF HORIZONTAL OR PER MANUFACTURER'S RECOMMENDATION. 2. IF INDICATED STRAIGHT RUN CANNOT BE OBTAINED, A FLOW -STRAIGHTENER SHALL BE PROVIDED AT THE BOX INLET. DAMPER CONTROLLER DAMPER CONTROLLER AIR-TERMINAL BOX 3D DD3 x D R = D 1.5 x DRE-HEAT COIL RE-HEAT COIL DAMPER CONTROLLER CONTROLLER VORTEX SHEDDING AIR VALVE R = D 1.5 x DMIN. 3D MIN. 3D MAINTAIN FULL SIZE OF DUCT LIP TO AIR VALVE. REDUCE AT INLET. DAMPER HW RE-HEAT COIL NOTES: 1. COORDINATE EXACT LOCATION OF 3" EXHAUST DROP WITH OWNER AND MILLWORK/EQUIPMENT INSTALLER. 2. 3" EXHAUST DUCT SHALL BE ROUTED ABOVE CEILING TO EXHAUST AIR DUCT. PROVIDE ADDITIONAL MANUAL BALANCE DAMPER AT THIS LOCATION. ABOVE-CEILING BALANCE DAMPER SHALL BE SET TO 50 CFM WITH POINT-OF-USE DAMPER AT FULL OPEN. WORK SURFACE HOOD / NOZZLE EXTRACTOR ARM ASSEMBLY EXTRACTOR ARM WALL BRACKET BLAST GATE EXHAUST DUCT WALL ANCHOR TO STUD SYSTEM PER EXTRACTION ARM MANUFACTURER LAB CABINET SYSTEM PER ARCHITECTURALAND LAB REQUIREMENTSHEIGHT PER. MANUFACTURERVOLUME DAMPER DAMPER CONTROLLER CONTROLLER EXHAUST BOX R = D 1.5 x DMIN. 3D MIN. 3D MAINTAIN FULL SIZE OF DUCT LIP TO AIR VALVE. REDUCE AT INLET. PETE'S PLUG (TYP) MANUAL AIR VENT STRAINER WITH BLOWDOWN BALL VALVE AND CAP. UNION (TYP) 3/4" COIL DRAIN VALVE WITH HOSE END CONNECTION AND CAP. CONTROL VALVEISOLATION BALL VALVE (TYP) SUPPLY RETURN BALANCE VALVE HEATING COIL NOTES: 1. BOX SENSOR SHALL BE ORIENTED IN SAME PLANE AS ELBOW AND BE WITHIN 10' OF HORIZONTAL OR PER MANUFACTURER'S RECOMMENDATION. 2. IF INDICATED STRAIGHT RUN CANNOT BE OBTAINED, A FLOW -STRAIGHTENER SHALL BE PROVIDED AT THE BOX INLET. DAMPER CONTROLLER DAMPER CONTROLLER AIR-TERMINAL BOX 3D DD3 x D R = D 1.5 x DEXHAUST DUCT FLAMMABLE STORAGE CABINET VOLUME DAMPER FLAMMABLE STORAGE CABINET EXHAUST CONNECTION WITH FLAME ARRESTOR LOCATION PER CABINET MANUFACTURER REDUCER TO MATCH OPENING SIZE BLAST GATE EXHAUST DUCT VACUUM CABINET VOLUME DAMPER VACUUM CABINET EXHAUST CONNECTION LOCATION PER CABINET MANUFACTURER VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 1:58:35 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 JB HVAC DETAILS AST CEV M-500 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 NO SCALE 2 DUCT TAKE-OFFS NO SCALE 4 LINED TRANSFER DUCT WITH GRILLE NO SCALE 3 CEILING DIFFUSER WITH FLEX DUCT INSTALLATION NO SCALE 1 DUCT SUPPORT ATTACHMENTS NO SCALE 7 SUPPLY AIR TERMINAL BOX CONNECTIONS NO SCALE 6 VORTEX SHEDDING SUPPLY AIR VALVE BOX CONNECTIONS NO SCALE 5 LAB BENCH EXTRACTION ARM DETAIL NO SCALE 9 VORTEX SHEDDING EXHAUST AIR VALVE BOX CONNECTIONS NO SCALE 8 RE-HEAT COIL DETAIL NO SCALE 10 EXHAUST AIR TERMINAL BOX CONNECTIONS NO SCALE 11 FLAMMABLE CABINET EXHAUST DETAIL NO SCALE 12 VAC CABINET EXHAUST DETAIL NO ORIFICE RING 2' - 0" MIN.SECTION #1 SEE CHART SECTION #2 SEE CHART SECTION #3 SEE CHART SECTION #4 SEE CHART TRANSITION ORIFICE RING TYP. ORIFICE RINGS AT THE END OF EACH PERFORATED SECTION (TYPICAL OF 3). SEE CHART BELOW FOR SIZING 360 DEGREE PERFORATED METAL WITH 50% OPEN AREA. 22 GAUGE 304 SS 3/16" DIA HOLES ON 1/4" STAGGERED CENTERS END CAP END VIEW PERFORATED DUCT SCHEDULE SECTION LENGTH DIAMETER (IN)PERFORATION DISCHARGE FLOW (CFM) MAX DISCHARGE VELOCITY (FPM) ORIFICE ID (IN) 1 25% 20" 360 deg. 50% 30FPM NONE 1 25% 20" 360 deg. 50% 30FPM 17.35 1 25% 20" 360 deg. 50% 30FPM 16.37 1 25% 20" 360 deg. 50% 30FPM 14.21 TOTAL AS SHOWN ON DRAWINGS AB 3"⌀DOWN, 100 CFM FLAMMABLE STORAGE CABINET, PROVIDE BALANCING DAMPER ON EACH BRANCH, BALANCE TO 25 CFM3ø6ø 2ø2ø 3ø3ø10øVACUUM STORAGE CABINET, PROVIDE BALANCING DAMPER, BALANCE TO 50 CFM DUCT TOP RIVETED TO FIRE DAMPER FRAME 16 GA. GALVANIZED STEEL BLADES WITH INTERLOCKING JOINTS BLADE AND LINK CINCH BREAKAWAY CONNECTIONS MOUNTING ANGLES ALL AROUND (TYP.) 16 GA. STEEL FIRE DAMPER SLEEVE (TYP.) STANDARD REPLACEABLE FUSIBLE LINK (AD) HINGED ACCESS DOOR (EITHER SIDE OR BOTTOM) BOLT DAMPER TO SLEEVE AND WALL (TYP.) FIRE-RATED WALL OR PARTITION (TYPE AND SIZE VARIES). NOTES: 1. ANY CLEARANCE BETWEEN FIRE-RATED WALL OR PARTITION AND DAMPER SLEEVE OR DAMPER SHALL BE FILLED WITH FIRE-RESISTANT PACKING ON ALL SIDES TO MAINTAIN FIRE RATING. 2. DAMPER BLADES SHALL BE OUT OF AIRSTREAM (TYPE "C") WHEN OPEN (100% FREE AREA) UNLESS DUCT DIMENSIONS DICTATE MULTIPLE DAMPER SECTIONS IN WHICH CASE TYPE "B" MAY BE USED. 3. FOR HORIZONTAL APPLICATION PROVIDE SPRING LOADED CLOSURE. 4. WHEN DUCTWORK IS INSULATED OR LINED, PROVIDE INSULATED ACCESS DOOR. 5. ACCESS DOOR SHALL BE 12" X 12" OR LARGER IF REQUIRED FOR FUSIBLE LINK REPLACEMENT. 6. TYPE "B" FIRE DAMPERS (BLADES OUT OF AIR STREAM) MAY BE SUBSTITUTED FOR TYPE "C" WHERE VELOCITIES ARE UNDER 1500 FPM IN LOW PRESSURE DUCT SYSTEMS ONLY. AIR FLOW (2) 2" CONNECTIONS TO THE CABINET 3" EXHAUST DUCT FLAMMABLE STORAGE CABINET UNDER BENCH TOP A B FIFTH FLOOR +92' -0" A B 3ø 2ø 2ø 3ø 3ø 2ø 2ø 10ø 6ø 10ø20ø 3" TO VENTED VACUUM PUMP (2) 2" CONNECTIONS TO SOLVENT STORAGE CABINET (2) 2" CONNECTIONS TO SOLVENT STORAGE CABINET 3" DROPS INSIDE HOOD CHASE (2) 2" CONNECTIONS TO SOLVENT STORAGE CABINET OPPOSITE SIDE VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 1:58:36 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 JB HVAC DETAILS AST CEV M-501 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 NO SCALE 1 PERFORATED DIFFUSER DETAIL NO SCALE 5 CABINET CONNECTION DETAIL NO SCALE 2 FIRE DAMPER DETAIL (FD) NO SCALE 3 FLAMMABLE STORAGE CABINET DETAIL NO SCALE 4 VENTED SOLVENT CABINET DETAIL SUPPLY AIR VALVE SCHEDULE UNIT TAG SERVE VALVE QTY. MOUNTING POSITION FACTORY OCCUPIED SET POINT UNOCCUPIED PD @ MAX DESIGN CFM (IN WC) INLET SIZE (IN.) RAD N.C. AT 1" S.P. 125 Hz DISC. N.C. AT 1" S.P. 125 Hz MANUFACTURER & MODEL NOTES MAX CFM MIN CFM MAX CFM MIN CFM MAX CFM MIN CFM SAV-1 LAB 580 2 HORIZONTAL 3,200 260 2,330 475 2,330 260 0.25 18"x12" 57 67 ACCUTROL AVC6418-05-IS 1,2,3,4,5 SAV-2 LAB 573 1 HORIZONTAL 1,790 180 1,240 450 1,240 200 0.21 12" 50 64 ACCUTROL AVC6412-05-IS 1,2,3,4,5 NOTES: 1. PROVIDE HIGH SPEED ELECTRIC ACTUATION. 2. UNIT TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. 3. ACTUATOR TO FAIL NORMALLY CLOSED. 4. PROVIDE OPTION FOR TIGHT SHUT OFF. 5. PROVIDE INSULATED UNIT. EXHAUST AIR VALVE SCHEDULE UNIT TAG SERVE VALVE QTY. MOUNTING POSITION FACTORY OCCUPIED SET POINT UNOCCUPIED PD @ MAX DESIGN CFM (IN WC) INLET SIZE (IN.) RAD N.C. AT 1" S.P. 125 Hz EXHAUST N.C. AT 1" S.P. 125 Hz MANUFACTURER & MODEL NOTES MAX CFM MIN CFM MAX CFM MIN CFM MAX CFM MIN CFM EAV-1 FUME HOOD 1 HORIZONTAL 1300 120 670 120 670 120 0.12 10 51 61 ACCUTROL AVC6210-05 1,2,3,5 EAV-2 FUME HOOD 1 HORIZONTAL 1300 120 670 120 670 120 0.12 10 51 61 ACCUTROL AVC6210-05 1,2,3,5 EAV-3 FUME HOOD 1 HORIZONTAL 1300 120 670 120 670 120 0.12 10 51 61 ACCUTROL AVC6210-05 1,2,3,5 EAV-4 FUME HOOD 1 HORIZONTAL 1300 120 670 120 670 120 0.12 10 51 61 ACCUTROL AVC6210-05 1,2,3,5 EAV-5 GENERAL EXHAUST 1 HORIZONTAL 254 0 250 0 0 0 0.30 6 32 50 ACCUTROL AVC6406 1,2,3,4,5 EAV-6 FUME HOOD 1 HORIZONTAL 1300 120 670 150 670 150 0.12 10 51 61 ACCUTROL AVC6210-05 1,2,3,5 EAV-7 FUME HOOD 1 HORIZONTAL 1300 120 670 150 670 150 0.12 10 51 61 ACCUTROL AVC6210-05 1,2,3,5 EAV-8 GENERAL EXHAUST 1 HORIZONTAL 254 0 250 0 0 0 0.30 6 32 50 ACCUTROL AVC6406 1,2,3,4,5 NOTES: 1. UNIT TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. 2. ACTUATOR TO FAIL NORMALLY OPEN. 3. PROVIDE HIGH SPEED ELECTRIC ACTUATION. 4. ROVIDE OPTION FOR TIGHT SHUT OFF. HOT WATER REHEAT COIL SCHEDULE UNIT TAG SERVE EAT (°F) LAT (°F)CFM MBH APD IN. H2O EWT (°F) LWT (°F)GPM WPD (FT. HD) WIDTH (IN) HEIGHT (IN) FACE VEL. (FPM) ROWS FINS/IN MANUFACTURER & MODEL RH-1 LAB 580 55 80 2,330 62.9 0.09 180 139 3.00 5.80 27 21 592 1 10 AEROFIN HWP-10.0AF-21.0 X 27.0-1-11 RH-2 LAB 573 55 80 1,240 33.5 0.14 180 139 2.00 1.10 21 15 567 1 8 AEROFIN HWP-8.0AW-15.0 X 21.0-1-11 RH-3 WRITE UP 580A 55 80 250 6.8 0.12 180 139 0.34 0.10 9 9 444 1 12 AEROFIN HWP-12.0AW-9.0 X 9.0-1-11 REGISTER, GRILL & DIFFUSER SCHEDULE UNIT TAG TYPE FACE LOCATION MATERIAL FINISH USE MANUFACTURER & MODEL NOTES S-1 SQUARE SEE PLAN STEEL BY ARCH. SUPPLY PRICE SPD 1,2,3 R-1 SQUARE SEE PLAN STEEL BY ARCH. RETURN/TRANSFER PRICE 535 1,4 R-2 SQUARE SEE PLAN ALUMINUM BY ARCH. GENERAL EXHAUST PRICE 635 1 NOTES: 1. SEE PLANS FOR NECK SIZE. 2. 24X24 LAY-IN, PROVIDE ADAPTER WITH PROPER NECK SIZE WHERE DUCT CONNECTIONS ARE SHOWN ON DRAWINGS. 3. VOLUME DAMPER TO BE INSTALLED ON ALL BRANCH DUCTS SERVING EACH DIFFUSER. 4. PROVIDE BORDER/PANEL FOR LAY-IN APPLICATION. CONTROL VALVE SCHEDULE EQUIP. TAG MFG MODEL VALVE TYPE VALVE BODY TYPE SERVICE FLUID TYPE ENT FLUID TEMP °F FLUID FLOW SIZE (IN) ΔP (PSIG) Cv CALC Cv ACTUAL MAX PRESSURE (PSIG) ACTUATOR NOTESGPMTYPE (PNEUM OR ELEC)RANGE ON / OFF or MODULATING FAIL POSITION CV-1 BELIMO B211 2-WAY FBNP RH-1 WATER 180 3.0 1/2 2.25 1.5 1.9 400 ELEC --- MODULATING NO SR 2,3,5,7 CV-2 BELIMO B210 2-WAY FBNP RH-2 WATER 180 2.0 1/2 4 1 1.2 400 ELEC --- MODULATING NC SR 2,3,5,7 CV-3 BELIMO B209 2-WAY FBNP RH-3 WATER 180 0.34 1/2 0.12 0.17 0.8 400 ELEC --- MODULATING NC SR 2,3,5,7 NOTES: 1. FLANGES SIZES SHALL BE BASED ON MAX. PRESSURES 2. ADJUSTMENTS TO CALCULATED CV'S PER VENDOR INPUT 3. CONTRACTOR TO VERIFY VALVE SIZE PRIOR TO ORDERING 4. CS = CARBON STEEL 5. FBNP = FORGED BRASS, NICKEL PLATED 6. NC SR = NORMALLY CLOSED, SPRING RETURN 7. NO SR = NORMALLY OPEN, SPRING RETURN 8. FL = FAIL LAST CAV AIR TERMINAL UNIT SCHEDULE UNIT TAG TYPE SERVE DESIGN CFM DESIGN MIN CFM INLET SIZE MAX. NC INLET SP MANUFACTURER & MODEL NOTES CAV-1 EXHAUST LAB 580A 350 350 5 20 0.30 PRICE SDE5 1,4,5,7,8 CAV-2 EXHAUST LAB 573 225 225 5 20 0.30 PRICE SDE5 1,4,5,7,8 CAV-3 SUPPLY WRITE-UP 580A 250 0 5 20 0.30 PRICE SDV5 1,2,3,4,5,6,7,8 NOTES: 1. PROVIDE PRESSURE INDEPENDENT FLOW CONTROL. 2. DISCHARGE AIR TEMPERATURE SENSOR TO BE PROVIDED BY BACS CONTRACTOR. 3. UNIT TO BE CONTROLLED BY VACANCY SENSOR . 4. PROVIDE DIRECT DIGITAL CONTROL ARRANGEMENT. 5. LOCATE CONTROLS ENCLOSURE AS INDICATED ON PLANS, CONTROLS TO BE SUPPLIED BY THE BACS CONTRACTOR. 6. UNIT SHALL BE INSTALLED ABOVE CEILING. 7. UNIT TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. 8. PROVIDE INTEGRAL AIR FLOW SENSOR. 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 1:58:37 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 JB HVAC SCHEDULES AST CEV M-600 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 BACS CONTROL SYMBOL LEGEND ANALOG INPUT ANALOG OUTPUT BINARY INPUT BINARY OUTPUT ANALOG VALUE BINARY VALUE VARIABLE FREQUENCY DRIVE NORMALLY CLOSED NORMALLY OPEN FAIL LAST POSITION T BINARY POINT F COM ANALOG POINT SYMBOL AI AO BI BO AV BV VFD N.C. N.O. F.L.P. NAME TEMPERATURE SENSOR FLOW SENSOR NETWORK COMMUNICATION INTERFACE POINT, BACnet MSTP MOD MODULATING DEVICE TSA D ROOM TEMPERATURE SENSOR W/ SETPOINT ADJUSTMENT & VISUAL DISPLAY SYMBOL NAME OC OCCUPANCY SENSOR VO PUSH-BUTTON EMERGENCY VENTILATION OVERRIDE VS VACANCY/ OCCUPANCY SENSOR T TEMPERATURE SENSOR W/ SETPOINT ADJUSTMENT & VISUAL DISPLAY SA D COMBINATION TEMPERATURE AND RELATIVE HUMIDITY (RNET) SENSOR RH RELATIVE HUMIDITY SENSOR GENERAL NOTE: 1. RH TRENDED AND SHOWN AS GRAPHICS 2. RH SENSOR USED TO CALCULATE DEW POINT IN BMS DEVICE INTERCONNECTION WIRING AO ANALOG OUTPUT - DEVICE INTERCONNECTION WIRING VAV BOX VORTEX SHEDDING BOX VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 1:58:37 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 TJ BMS CONTROLS LEGEND AND NOTES AST CEV MI-000 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 SYSTEM DESCRIPTION: FUME HOODS EACH WITH AN EXHAUST AIR VALVE (EAV-1, EAV-2, EAV-3 & EAV-4) SUPPLY AIR VALVE (SAV-1) GENERAL EXHAUST AIR VALVE (EAV-5) DUCT MOUNTED RE-HEAT COIL (RH-1) CONSTANT AIR VOLUME BOX (CAV-1) GENERAL: 1. SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). 2. ALL SETPOINTS AND FLOW OFFSETS SHALL BE ADJUSTABLE. 3. THE SPACE SHALL BE CONTROLLED TO AN AIR CHANGE RATE TO COMPLY WITH CODE VENTILATION REQUIREMENTS AND UNIVERSITY STANDARDS. 4. LABORATORY AIR CHANGE RATES ARE BASED ON TOTAL EXHAUST AIR FLOW FROM THE SPACE. 5. THE BAS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM FOR SEVEN DIFFERENT DAILY SCHEDULES PER WEEK. 6. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. 7. REFER TO LABORATORY AIR FLOW SCHEDULE ON DRAWING MI-601 FOR SCHEDULED AIR FLOW AND OFFSET VALUES. 8. ZONE OCCUPANCY (OCCUPIED MODE) SCHEDULE: 6 AM TO 8 PM, MON - FRI. SETPOINTS: SPACE COOLING TEMPERATURE SETPOINTS: OCCUPIED: 75 °F +/- 1.5 °F OCCUPIED SETBACK: 75 °F +/- 3 °F UNOCCUPIED: 75 °F +/- 6 °F SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED: 70 °F +/- 1.5 °F OCCUPIED SETBACK: 70 °F +/- 3 °F UNOCCUPIED: 70 °F +/- 6 °F TOTAL EXHAUST AIR CHANGE RATE (ACPH): TYPICALLY = 8 ACPH OCCUPIED / 4 ACPH UNOCCUPIED ACPH = TOTAL EXHAUST CFM x 60 / ROOM VOLUME TOTAL EXHAUST (EX) FLOW RATE (CFM): REFER TO LABORATORY 580 AIRFLOW SCHEDULE ON MI-601 SUPPLY AIRFLOW (SA) RATE (CFM): REFER TO LABORATORY 580 AIRFLOW SCHEDULE ON MI-601 TYPICAL SA FLOW = TOTAL EA FLOW RATE + OFFSET FUME HOOD EXHAUST (FHE) AIRFLOW RATE: NOT CONTROLLED BY BACS. VALVE IS CONTROLLED BY FUME HOOD MONITOR TO MAINTAIN FACE VELOCITY SETPOINT GENERAL EXHAUST (GEX) AIRFLOW RATE (CFM): REFER TO LABORATORY 580 AIRFLOW SCHEDULE ON MI-601 TYPICAL GEX FLOW = TOTAL LABORATORY EXHAUST CFM - FUME HOOD EXHAUST CFM – CAV-1 CFM. SPACE AIR DIFFERENTIAL OFFSET (CFM): REFER TO LABORATORY 580 AIRFLOW SCHEDULE ON MI-601 TYPICALLY = -100 CFM FOR NEGATIVE PRESSURE LABS TYPICALLY = +100 CFM FOR POSITIVE PRESSURE LABS FUME HOOD VELOCITY: NOT CONTROLLED BY BACS. FACE VELOCITY SETPOINTS ARE PROGRAMMED INTO FUME HOOD MONITOR. TYPICALLY 100 FPM OCC. / 65 FPM UNOCC. MINIMUM LABORATORY OCCUPANCY INDEX TIME: 30 MINUTES ZONE OCCUPANCY SCHEDULE: 6AM TO 8PM, MONDAY-FRIDAY FACE VELOCITY CONTROL: EACH FUME HOOD SHALL BE EQUIPPED WITH A FUME HOOD MONITOR AND SASH POSITION INDICATOR. THE MONITOR SHALL ADJUST THE FUME HOOD EXHAUST VALVE TO MAINTAIN THE FACE VELOCITY SETPOINT. THE MONITOR SHALL, AS A MINIMUM, HAVE THE FOLLOWING CAPABILITIES: - SASH POSITION INPUT. - STANDBY MODE INPUT TO ALLOW ADJUSTMENTS OF FACE VELOCITY. - HOOD DECOMMISSION MODE. ROOM PRESSURIZATION CONTROL: THE GENERAL EXHAUST AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE OCCUPIED AIR CHANGE RATE. THE SUPPLY AIR VALVES SHALL MODULATE AS NEEDED TO MAINTAIN AIRFLOW DIFFERENTIAL FOR ROOM PRESSURIZATION. THE SUPPLY FLOW SETPOINT SHALL (SAV-1) BE COMPUTED FROM THE TOTAL MEASURED LABORATORY EXHAUST FLOW MINUS THE SCHEDULED OFFSET FLOW. THE GENERAL EXHAUST AIR FLOW SETPOINT (EAV-5) SHALL BE COMPUTED FROM THE TOTAL LABORATORY EXHAUST FLOW SCHEDULED VALUE MINUS THE MEASURED FUME HOOD EXHAUST FLOWS MINUS THE MEASURED CAV-1 FLOW. ZONE TEMPERATURE CONTROL: TEMPERATURE SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF PROGRAMMED SCHEDULE AND STATUS OF SPACE VACANCY SENSORS. HEATING MODE: SHOULD THE SPACE TEMPERATURE FALL BELOW SETPOINT, THE HEATING SETPOINT SHALL BE MAINTAINED BY MODULATING THE RE-HEAT COIL CONTROL VALVE. SCHEDULED OCCUPIED PERIOD - VACANCY SENSOR ACTIVE: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. SPACE SHALL BE MAINTAINED AT THE OCCUPIED HEATING TEMPERATURE SETPOINT. SCHEDULED OCCUPIED PERIOD - VACANCY SENSOR INACTIVE: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED SETBACK MODE. SPACE SHALL BE MAINTAINED AT THE OCCUPIED SETBACK HEATING TEMPERATURE SETPOINT. SCHEDULED UNOCCUPIED PERIOD - VACANCY SENSOR ACTIVE:IF THE SPACE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. SPACE SHALL BE MAINTAINED AT THE OCCUPIED HEATING TEMPERATURE SETPOINT. WHEN THE SPACE BECOMES UNOCCUPIED AGAIN DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX BACK TO UNOCCUPIED MODE. SCHEDULED UNOCCUPIED PERIOD - VACANCY SENSOR INACTIVE: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO UNOCCUPIED MODE. SPACE SHALL BE MAINTAINED AT THE UNOCCUPIED HEATING TEMPERATURE SETPOINT. COOLING MODE: SHOULD THE SPACE TEMPERATURE RISES ABOVE THE COOLING TEMPERATURE SETPOINT, THE GENERAL EXHAUST AIR SHALL MODULATE OPEN TO MAINTAIN THE OCCUPIED SPACE TEMPERATURE SETPOINT. THE SUPPLY AIR VALVES SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL FOR ROOM PRESSURIZATION. AT NO TIME SHALL THE SPACE DROP BELOW THE MINIMUM OCCUPIED EXCHANGE RATE. SCHEDULED OCCUPIED PERIOD - VACANCY SENSOR ACTIVE: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. SPACE SHALL BE MAINTAINED AT THE OCCUPIED COOLING TEMPERATURE SETPOINT. SCHEDULED OCCUPIED PERIOD - VACANCY SENSOR INACTIVE: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED SETBACK MODE. SPACE SHALL BE MAINTAINED AT THE OCCUPIED SETBACK COOLING TEMPERATURE SETPOINT. SCHEDULED UNOCCUPIED PERIOD - VACANCY SENSOR ACTIVE:IF THE SPACE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. SPACE SHALL BE MAINTAINED AT THE OCCUPIED COOLING TEMPERATURE SETPOINT. WHEN THE SPACE BECOMES UNOCCUPIED AGAIN DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX BACK TO UNOCCUPIED MODE. SCHEDULED UNOCCUPIED PERIOD - VACANCY SENSOR INACTIVE: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO UNOCCUPIED MODE. SPACE SHALL BE MAINTAINED AT THE UNOCCUPIED COOLING TEMPERATURE SETPOINT. LABORATORY AIRFLOW CONTROL: AIR VALVE POSITIONS SHALL BE BASED ON OCCUPANCY MODE. UNDER NORMAL CONDITIONS, ROOM OCCUPANCY SHALL BE DETERMINED VIA THE ROOM VACANCY SENSORS. IF THE LABORATORY IS VACANT, THE ROOM SHALL BE PLACED IN VACANT MODE BY THE BACS. WHEN THE ROOM IS OCCUPIED, THE BACS SHALL SEND AN OCCUPIED COMMAND TO THE FUME HOOD MONITOR. THE FUME HOOD MONITOR SHALL INDEX THE FUME HOOD EXHAUST AIR VALVE AS NEEDED TO MAINTAIN THE OCCUPIED FACE VELOCITY SETPOINT BASED ON MEASURED AIR VELOCITY. THE GENERAL EXHAUST AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE OCCUPIED AIR CHANGE RATE. THE SUPPLY AIR VALVES SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL FOR ROOM PRESSURIZATION. WHEN THE ROOM IS UNOCCUPIED, AND ALL THE FUME HOOD SASHS ARE AT OR BELOW 18-INCHES, THE BACS SHALL SEND AN UNOCCUPIED COMMAND TO THE FUME HOOD MONITOR. THE FUME HOOD MONITOR SHALL INDEX THE FUME HOOD EXHAUST AIR VALVE AS NEEDED TO MAINTAIN THE UNOCCUPIED FACE VELOCITY SETPOINT BASED ON MEASURED AIR VELOCITY. THE GENERAL EXHAUST AIR VALVES SHALL MODULATE AS NEEDED TO MAINTAIN THE UNOCCUPIED AIR CHANGE RATE. THE SUPPLY AIR VALVES SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL FOR ROOM PRESSURIZATION. WHEN THE ROOM IS UNOCCUPIED, AND ANY OF THE FUME HOOD SASHES ARE ABOVE 18-INCHES, THE BACS SHALL NOT SEND AN UNOCCUPIED COMMAND TO THOSE PARTICULAR FUME HOOD EXHAUST AIR VALVES. THE FUME HOOD MONITOR SHALL INDEX THE FUME HOOD EXHAUST AIR VALVE ON THOSE SASHES ABOVE 18 INCHES TO MAINTAIN THE OCCUPIED SASH OPEN AIRFLOW SETPOINT. THE BACS WILL SEND THE UNOCCUPIED COMMAND TO THOSE FUME HOODS WHOSE SASHES ARE AT OR BELOW 18 INCHES. THE FUME HOOD MONITORS SHALL INDEX THE FUME HOOD EXHAUST AIR VALVES WHOSE SASHES ARE AT 18 INCHES AND BELOW TO MAINTAIN THE UNOCCUPIED FACE VELOCITY SETPOINT BASED ON MEASURED AIR VELOCITY. THE GENERAL EXHAUST AIR VALVES SHALL MODULATE AS NEEDED TO MAINTAIN THE UNOCCUPIED AIR CHANGE RATE. THE SUPPLY AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL FOR ROOM PRESSURIZATION. 6' FUME HOOD 6' FUME HOOD FUME HOOD MONITOR VERTICAL SASH POSITION INDICATOR HORIZONTAL SASH POSITION INDICATOR 6' FUME HOOD 6' FUME HOOD HORIZONTAL SASH POSITION INDICATOR VERTICAL SASH POSITION INDICATOR EXHAUST ΔP EAV-2 EXHAUST ΔP EAV-3 EXHAUST ΔP EAV-4 EXHAUST ΔP EAV-1 AI FLOW AI ALARM R DO OCCUPIED/ UNOCCUPIED COMMAND R DO DECOMMISSION FHV ANALOG ELECTRIC CONTROL WITH HOOD INTERFACE CARD SAV-1 T RH-1SUPPLY AIR FROM MAU SAT SUMMER = 55 F SAT WINTER = 68 F ΔP AI AO F.L. ANALOG ELECTRIC CONTROL AI FLOW AI ALARM MOD AO SETPOINT MOD AIR FLOW SP AO CAV-1 EXHAUST FUME HOOD MONITOR FUME HOOD MONITOR FUME HOOD MONITOR AO AO AI AI AI FLOW AI ALARM R DO OCCUPIED/ UNOCCUPIED COMMAND R DO DECOMMISSION FHV ANALOG ELECTRIC CONTROL WITH HOOD INTERFACE CARD AI AI AI FLOW AI ALARM R DO OCCUPIED/ UNOCCUPIED COMMAND R DO DECOMMISSION FHV ANALOG ELECTRIC CONTROL WITH HOOD INTERFACE CARD AI VERTICLE SASH POSITION AI AI AI FLOW AI ALARM R DO OCCUPIED/ UNOCCUPIED COMMAND R DO DECOMMISSION FHV ANALOG ELECTRIC CONTROL WITH HOOD INTERFACE CARD AI AI AO AO AO AO VERTICAL SASH POSITION INDICATOR HORIZONTAL SASH POSITION INDICATOR AO AO HORIZONTAL SASH POSITION INDICATOR VERTICAL SASH POSITION INDICATOR EXHAUST ΔP EAV-5 AI FLOW AI ALARM ANALOG ELECTRIC CONTROL MOD AO SETPOINT VO BI T AV SETPOINT SA D AI VALVE POSITION AI AIR FLOW AI AI HORIZ. SASH POSITION AI HORIZ. SASH POSITION AI HORIZ. SASH POSITION AI HORIZ. SASH POSITION AI VERTICLE SASH POSITION AI VERTICLE SASH POSITION AI VERTICLE SASH POSITION VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 1:58:37 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 TJ CONTROLS SCHEMATIC LAB 580A AST CEV MI-600 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 LAB 580A POINTS LIST HIGH HOOD DENSITY TRACKING LABORATORY HARDWIRE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBI BO AI AO AV BV SCH TREND ALARM BACS EMCS DESCRIPTION TOTAL EXHAUST AIRFLOW (CFM)X X X TOTAL EXHAUST AIR SETPOINT (CFM)X X X LABORATORY AIR CHANGE RATE (ACPH)X X X ROOM AREA (SQUARE FEET)X X ROOM CEILING HEIGHT (FEET)X X FLOW OFFSET SETPOINT (CFM)X X FLOW OFFSET ACTUAL (CFM)X X SPACE TEMPERATURE SETPOINT, HEATING X X SPACE TEMPERATURE SETPOINT, COOLING X X SPACE TEMPERATURE (RNET)X X X =+/-4°F FROM SETPOINT X SPACE SETPOINT ADJUSTMENT (RNET)X X SPACE OCCUPANCY, MINIMUM OCCUPANCY SETPOINT X X SPACE OCCUPANCY X X X EAV-1 FUME HOOD EXHAUST AIR VALVE AIR FLOW (CFM)X X X EAV-1 FUME HOOD EXHAUST AIR VALVE STATUS X X X VALVE COMMAND ≠ FEEDBACK (JAM) LOW DIFFERENTIAL PRESSURE (VIA SWITCH) X TRI-STATE ALARM EAV-1 FUME HOOD EXHAUST AIR VALVE OCC/UNOCC COMMAND X X TRI-STATE ALARM EAV-1 FUME HOOD VERTICAL SASH POSITION X X X SASH OPEN (18") FOR 24 CONTINUOUS HOURS OR MORE X EAV-2 FUME HOOD HORIZONTAL SASH POSITION X X X EAV-1 DECOMMISSIONING COMMAND X X X EAV-2 FUME HOOD EXHAUST AIR VALVE AIR FLOW (CFM)X X X EAV-2 FUME HOOD EXHAUST AIR VALVE STATUS X X X VALVE COMMAND ≠ FEEDBACK (JAM) LOW DIFFERENTIAL PRESSURE (VIA SWITCH) X TRI-STATE ALARM EAV-2 FUME HOOD EXHAUST AIR VALVE OCC/UNOCC COMMAND X X TRI-STATE ALARM EAV-2 FUME HOOD VERTICAL SASH POSITION X X X SASH OPEN (18") FOR 24 CONTINUOUS HOURS OR MORE X EAV-2 FUME HOOD HORIZONTAL SASH POSITION X X X EAV-2 DECOMMISSIONING COMMAND X X X EAV-3 FUME HOOD EXHAUST AIR VALVE AIR FLOW (CFM)X X X EAV-3 FUME HOOD EXHAUST AIR VALVE STATUS X X X VALVE COMMAND ≠ FEEDBACK (JAM) LOW DIFFERENTIAL PRESSURE (VIA SWITCH) X TRI-STATE ALARM EAV-3 FUME HOOD EXHAUST AIR VALVE OCC/UNOCC COMMAND X X TRI-STATE ALARM EAV-3 FUME HOOD VERTICAL SASH POSITION X X X SASH OPEN (18") FOR 24 CONTINUOUS HOURS OR MORE X EAV-3 FUME HOOD HORIZONTAL SASH POSITION X X X EAV-3 DECOMMISSIONING COMMAND X X X EAV-4 FUME HOOD EXHAUST AIR VALVE AIR FLOW (CFM)X X X EAV-4 FUME HOOD EXHAUST AIR VALVE STATUS X X X VALVE COMMAND ≠ FEEDBACK (JAM) LOW DIFFERENTIAL PRESSURE (VIA SWITCH) X TRI-STATE ALARM EAV-4 FUME HOOD EXHAUST AIR VALVE OCC/UNOCC COMMAND X X TRI-STATE ALARM EAV-4 FUME HOOD VERTICAL SASH POSITION X X X SASH OPEN (18") FOR 24 CONTINUOUS HOURS OR MORE X EAV-4 FUME HOOD HORIZONTAL SASH POSITION X X X EAV-4 DECOMMISSIONING COMMAND X X X EAV-5 GENERAL EXHAUST AIR VALVE POSITION COMMAND (FLOW SETPOINT CFM)X X X EAV-5 GENERAL EXHAUST AIR VALVE MINIMUM AIRFLOW SETPOINT (CFM)X X EAV-5 GENERAL EXHAUST AIR VALVE MAXIMUM AIRFLOW SETPOINT (CFM)X X EAV-5 GENERAL EXHAUST AIR VALVE FLOW FEEDBACK (CFM)X X X EAV-5 GENERAL EXHAUST AIR VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMX VALVE COMMAND = FEEDBACK (JAM) X X LOW DIFFERENTIAL PRESSURE (VIA SWITCH) X LAB 580A POINTS LIST (CONTINUED) HIGH HOOD DENSITY TRACKING LABORATORY HARDWIRE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBI BO AI AO AV BV SCH TREND ALARM BACS EMCS DESCRIPTION SAV-1 SUPPLY AIR VALVE FLOW FEEDBACK (CFM) X X X SAV-1 SUPPLY AIR VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMXVALVE COMMAND ≠ FEEDBACK (JAM)X X LOW DIFFERENTIAL PRESSURE (VIA SWITCH)X SAV-1 SUPPLY AIR VALVE POSITION COMMAND (AIRFLOW SETPOINT CFM)X X X SAV-1 SUPPLY AIR VALVE MINIMUM AIRFLOW SETPOINT (CFM)X X SAV-1 SUPPLY AIR VALVE MAXIMUM AIRFLOW SETPOINT (CFM)X X SAV-1 SUPPLY AIR VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMX VALVE COMMAND = FEEDBACK (JAM) X X LOW DIFFERENTIAL PRESSURE (VIA SWITCH) X SAV-1 SUPPLY AIR VALVE FLOW FEEDBACK (CFM) X X X RH-1 RE-HEAT COIL LEAVING AIR TEMPERATURE X X X SINGLE POINT SENSOR RH-1 RE-HEAT COIL LEAVING AIR TEMPERATURE HIGH LIMIT X X X SINGLE POINT SENSOR SPACE TEMPERATURE SETPOINT X X X RH-1 RE-HEAT COIL VALVE POSITION X X X 5°F ΔT ACROSS COIL WITH VALVE COMMANDED CLOSED X FAIL FAST CAV-1 SUPPLY AIR VALVE FLOW FEEDBACK (CFM) X X X CAV-1 SUPPLY AIR VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMXVALVE COMMAND ≠ FEEDBACK (JAM)X X LOW DIFFERENTIAL PRESSURE (VIA SWITCH)X CAV-1 SUPPLY AIR VALVE POSITION COMMAND (AIRFLOW SETPOINT CFM)X X X CAV-1 SUPPLY AIR VALVE MINIMUM AIRFLOW SETPOINT (CFM)X X CAV-1 SUPPLY AIR VALVE MAXIMUM AIRFLOW SETPOINT (CFM)X X CAV-1 SUPPLY AIR VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMX VALVE COMMAND = FEEDBACK (JAM) X X LOW DIFFERENTIAL PRESSURE (VIA SWITCH) X CAV-1 SUPPLY AIR VALVE FLOW FEEDBACK (CFM) X X X LABORATORY 580A AIR FLOW SCHEDULE DESCRIPTION ROOM DIMENSIONS CODE MINIMUM VENTILATION EXHAUST AIR SUPPLY AIR XFER AREA HEIGHT VOLUME NYS OUTDOOR AIR NYS EXHAUST AIR EXHAUST POINT VALVE SIZE VALVE RANGE OCCUPIED SASH OPEN OCCUPIED SASH CLOSED UNOCCUPIED SASH FULL UNOCCUPIED SASH OPEN UNOCCUPIED SASH CLOSED SUPPLY POINT VALVE SIZE VALVE RANGE OCCUPIED SASH OPEN OCCUPIED SASH CLOSED UNOCCUPIED SASH FULL UNOCCUPIED SASH OPEN UNOCCUPIED SASH CLOSED ALL MODES MIN MAX 100 FPM 80 FPM MIN MAX 100 FPM 80 FPM (FT2)(FT)(FT3)(CFM) (ACH) (CFM) (ACH) (CFM) (CFM) (CFM) (ACH) (CFM) (ACH) (CFM) (ACH) (CFM) (ACH) (CFM) (ACH) (CFM) (ACH) (CFM) (CFM) (CFM) (CFM) (CFM) (CFM) (CFM) (CFM) (CFM) LAB 580 515 12 6,180 280 2.7 515 5.0 EAV-1 (FH) 10 120 1,056 670 26.0 535 20.8 150 8.0 670 26.0 490 19.0 150 5.8 SAV-1 18"x12" 260 2,596 2,330 1,790 475 2330 1610 260 -350 EAV-2 (FH) 10 120 1,056 670 535 150 670 490 150 EAV-3 (FH) 10 120 1,056 670 535 150 670 490 150 EAV-4 (FH) 10 120 1,056 670 535 150 670 490 150 EAV-5 (GEX) 6 0 254 0 0 225 0 0 0 TOTAL 2,680 2,140 825 2680 1960 600 VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 1:58:38 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 TJ CONTROLS POINTS LIST LAB 580A AST CEV MI-601 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 LABORATORY 573 AIR FLOW SCHEDULE DESCRIPTION ROOM DIMENSIONS CODE MINIMUM VENTILATION EXHAUST AIR SUPPLY AIR XFER AREA HEIGHT VOLUME NYS OUTDOOR AIR NYS EXHAUST AIR EXHAUST POINT VALVE SIZE VALVE RANGE OCCUPIED SASH OPEN OCCUPIED SASH CLOSED UNOCCUPIED SASH FULL UNOCCUPIED SASH OPEN UNOCCUPIED SASH CLOSED SUPPLY POINT VALVE SIZE VALVE RANGE OCCUPIED SASH OPEN OCCUPIED SASH CLOSED UNOCCUPIED SASH FULL UNOCCUPIED SASH OPEN UNOCCUPIED SASH CLOSED ALL MODES MIN MAX 100 FPM 80 FPM MIN MAX 100 FPM 80 FPM (FT2)(FT)(FT3)(CFM) (ACH) (CFM) (ACH) (CFM) (CFM) (CFM) (ACH) (CFM) (ACH) (CFM) (ACH) (CFM) (ACH) (CFM) (ACH) (CFM) (ACH) (CFM) (CFM) (CFM) (CFM) (CFM) (CFM) (CFM) (CFM) (CFM) LAB 573 342 12 4,104 190 2.8 342 5.0 EAV-6 (FH) 10 1,056 120 670 19.6 535 15.6 150 8.0 670 19.6 490 14.3 150 4.4 SAV-2 12 180 1,461 1,240 970 450 1240 880 200 -100 EAV-7 (FH) 10 1,056 120 670 535 150 670 490 150 EAV-8 (GEX) 6 0 254 0 0 250 0 0 0 TOTAL 1,340 1,070 550 1340 980 300 SYSTEM DESCRIPTION: FUME HOODS EACH WITH AN EXHAUST AIR VALVE (EAV-6, EAV-7) SUPPLY AIR VALVE (SAV-2) GENERAL EXHAUST AIR VALVE (EAV-8) DUCT MOUNTED RE-HEAT COIL (RH-2) CONSTANT AIR VOLUME BOX (CAV-2) GENERAL: 1. SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). 2. ALL SETPOINTS AND FLOW OFFSETS SHALL BE ADJUSTABLE. 3. THE SPACE SHALL BE CONTROLLED TO AN AIR CHANGE RATE TO COMPLY WITH CODE VENTILATION REQUIREMENTS AND UNIVERSITY STANDARDS. 4. LABORATORY AIR CHANGE RATES ARE BASED ON TOTAL EXHAUST AIR FLOW FROM THE SPACE. 5. THE BAS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM FOR SEVEN DIFFERENT DAILY SCHEDULES PER WEEK. 6. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. 7. REFER TO LABORATORY AIR FLOW SCHEDULE ON THIS DRAWING FOR SCHEDULED AIR FLOW AND OFFSET VALUES. 8. ZONE OCCUPANCY (OCCUPIED MODE) SCHEDULE: 6 AM TO 8 PM, MON - FRI. 9. DOWNSTREAM STATIC PRESSURE SETPOINT: DETERMINE DURING TESTING AND BALANCING EFFORTS. SETPOINTS: SPACE COOLING TEMPERATURE SETPOINTS: OCCUPIED: 75 °F +/- 1.5 °F OCCUPIED SETBACK: 75 °F +/- 3 °F UNOCCUPIED: 75 °F +/- 6 °F SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED: 70 °F +/- 1.5 °F OCCUPIED SETBACK: 70 °F +/- 3 °F UNOCCUPIED: 70 °F +/- 6 °F TOTAL EXHAUST AIR CHANGE RATE (ACPH): TYPICALLY = 8 ACPH OCCUPIED / 4 ACPH UNOCCUPIED ACPH = TOTAL EXHAUST CFM x 60 / ROOM VOLUME TOTAL EXHAUST (EX) FLOW RATE (CFM): REFER TO LABORATORY 573 AIRFLOW SCHEDULE SUPPLY AIRFLOW (SA) RATE (CFM): REFER TO LABORATORY AIRFLOW 573 SCHEDULE TYPICAL SA FLOW = TOTAL EA FLOW RATE + OFFSET FUME HOOD EXHAUST (FHE) AIRFLOW RATE: NOT CONTROLLED BY BACS. VALVE IS CONTROLLED BY FUME HOOD MONITOR TO MAINTAIN FACE VELOCITY SETPOINT GENERAL EXHAUST (GEX) AIRFLOW RATE (CFM): REFER TO LABORATORY 573 AIRFLOW SCHEDULE ON MI-602. TYPICAL GEX FLOW = TOTAL LABORATORY EXHAUST CFM - FUME HOOD EXHAUST CFM SPACE AIR DIFFERENTIAL OFFSET (CFM): REFER TO LABORATORY 573 AIRFLOW SCHEDULE TYPICALLY = -100 CFM FOR NEGATIVE PRESSURE LABS TYPICALLY = +100 CFM FOR POSITIVE PRESSURE LABS FUME HOOD VELOCITY: NOT CONTROLLED BY BACS. FACE VELOCITY SETPOINTS ARE PROGRAMMED INTO FUME HOOD MONITOR. TYPICALLY 100 FPM OCC. / 65 FPM UNOCC. MINIMUM LABORATORY OCCUPANCY INDEX TIME: 30 MINUTES ZONE OCCUPANCY SCHEDULE: 6AM TO 8PM, MONDAY-FRIDAY FACE VELOCITY CONTROL: EACH FUME HOOD SHALL BE EQUIPPED WITH A FUME HOOD MONITOR AND SASH POSITION INDICATOR. THE MONITOR SHALL ADJUST THE FUME HOOD EXHAUST VALVE TO MAINTAIN THE FACE VELOCITY SETPOINT. THE MONITOR SHALL, AS A MINIMUM, HAVE THE FOLLOWING CAPABILITIES: - SASH POSITION INPUT. - STANDBY MODE INPUT TO ALLOW ADJUSTMENTS OF FACE VELOCITY. - HOOD DECOMMISSION MODE. ROOM PRESSURIZATION CONTROL: THE GENERAL EXHAUST AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE OCCUPIED AIR CHANGE RATE. THE SUPPLY AIR VALVES SHALL MODULATE AS NEEDED TO MAINTAIN AIRFLOW DIFFERENTIAL FOR ROOM PRESSURIZATION. THE SUPPLY FLOW SETPOINT SHALL (SAV-2) BE COMPUTED FROM THE TOTAL MEASURED LABORATORY EXHAUST FLOW MINUS THE SCHEDULED OFFSET FLOW. THE GENERAL EXHAUST AIR FLOW SETPOINT (EAV-8) SHALL BE COMPUTED FROM THE TOTAL LABORATORY EXHAUST FLOW SCHEDULED VALUE MINUS THE MEASURED FUME HOOD EXHAUST FLOWS MINUS THE MEASURED CAV-2 FLOW. ZONE TEMPERATURE CONTROL: TEMPERATURE SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF PROGRAMMED SCHEDULE AND STATUS OF SPACE VACANCY SENSORS. HEATING MODE: SHOULD THE SPACE TEMPERATURE FALL BELOW SETPOINT, THE HEATING SETPOINT SHALL BE MAINTAINED BY MODULATING THE RE-HEAT COIL CONTROL VALVE. SCHEDULED OCCUPIED PERIOD - OCCUPANCY SENSOR ACTIVE:IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. SPACE SHALL BE MAINTAINED AT THE OCCUPIED HEATING TEMPERATURE SETPOINT. SCHEDULED OCCUPIED PERIOD - OCCUPANCY SENSOR INACTIVE: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED SETBACK MODE. SPACE SHALL BE MAINTAINED AT THE OCCUPIED SETBACK HEATING TEMPERATURE SETPOINT. SCHEDULED UNOCCUPIED PERIOD - VACANCY SENSOR ACTIVE:IF THE SPACE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. SPACE SHALL BE MAINTAINED AT THE OCCUPIED HEATING TEMPERATURE SETPOINT. WHEN THE SPACE BECOMES UNOCCUPIED AGAIN DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX BACK TO UNOCCUPIED MODE. SCHEDULED UNOCCUPIED PERIOD - OCCUPANCY SENSOR INACTIVE: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO UNOCCUPIED MODE. SPACE SHALL BE MAINTAINED AT THE UNOCCUPIED HEATING TEMPERATURE SETPOINT. COOLING MODE: SHOULD THE SPACE TEMPERATURE RISES ABOVE THE COOLING TEMPERATURE SETPOINT, THE GENERAL EXHAUST AIR SHALL MODULATE OPEN TO MAINTAIN THE OCCUPIED SPACE TEMPERATURE SETPOINT. THE SUPPLY AIR VALVES SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL FOR ROOM PRESSURIZATION. AT NO TIME SHALL THE SPACE DROP BELOW THE MINIMUM OCCUPIED EXCHANGE RATE. SCHEDULED OCCUPIED PERIOD - VACANCY SENSOR ACTIVE: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. SPACE SHALL BE MAINTAINED AT THE OCCUPIED COOLING TEMPERATURE SETPOINT. SCHEDULED OCCUPIED PERIOD - VACANCY SENSOR INACTIVE: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED SETBACK MODE. SPACE SHALL BE MAINTAINED AT THE OCCUPIED SETBACK COOLING TEMPERATURE SETPOINT. SCHEDULED UNOCCUPIED PERIOD - VACANCY SENSOR ACTIVE:IF THE SPACE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. SPACE SHALL BE MAINTAINED AT THE OCCUPIED COOLING TEMPERATURE SETPOINT. WHEN THE SPACE BECOMES UNOCCUPIED AGAIN DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX BACK TO UNOCCUPIED MODE. SCHEDULED UNOCCUPIED PERIOD - VACANCY SENSOR INACTIVE: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO UNOCCUPIED MODE. SPACE SHALL BE MAINTAINED AT THE UNOCCUPIED COOLING TEMPERATURE SETPOINT. LABORATORY AIRFLOW CONTROL: AIR VALVE POSITIONS SHALL BE BASED ON OCCUPANCY MODE. UNDER NORMAL CONDITIONS, ROOM OCCUPANCY SHALL BE DETERMINED VIA THE ROOM VACANCY SENSORS. IF THE LABORATORY IS VACANT, THE ROOM SHALL BE PLACED IN VACANT MODE BY THE BACS. WHEN THE ROOM IS OCCUPIED, THE BACS SHALL SEND AN OCCUPIED COMMAND TO THE FUME HOOD MONITOR. THE FUME HOOD MONITOR SHALL INDEX THE FUME HOOD EXHAUST AIR VALVE AS NEEDED TO MAINTAIN THE OCCUPIED FACE VELOCITY SETPOINT BASED ON MEASURED AIR VELOCITY. THE GENERAL EXHAUST AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE OCCUPIED AIR CHANGE RATE. THE SUPPLY AIR VALVES SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL FOR ROOM PRESSURIZATION. WHEN THE ROOM IS UNOCCUPIED, AND THE FUME HOOD SASHS ARE AT OR BELOW 18-INCHES, THE BACS SHALL SEND AN UNOCCUPIED COMMAND TO THE FUME HOOD MONITOR. THE FUME HOOD MONITOR SHALL INDEX THE FUME HOOD EXHAUST AIR VALVE AS NEEDED TO MAINTAIN THE UNOCCUPIED FACE VELOCITY SETPOINT BASED ON MEASURED AIR VELOCITY. THE GENERAL EXHAUST AIR VALVES SHALL MODULATE AS NEEDED TO MAINTAIN THE UNOCCUPIED AIR CHANGE RATE. THE SUPPLY AIR VALVES SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL FOR ROOM PRESSURIZATION. WHEN THE ROOM IS UNOCCUPIED, AND ANY OF THE FUME HOOD SASHES ARE ABOVE 18-INCHES, THE BACS SHALL NOT SEND AN UNOCCUPIED COMMAND TO THOSE PARTICULAR FUME HOOD EXHAUST AIR VALVES. THE FUME HOOD MONITOR SHALL INDEX THE FUME HOOD EXHAUST AIR VALVE WHOSE SASHES ARE ABOVE 18 INCHES TO MAINTAIN THE OCCUPIED SASH OPEN AIRFLOW SETPOINT. THE BACS WILL SEND THE UNOCCUPIED COMMAND TO THOSE FUME HOODS WHOSE SASHES ARE AT OR BELOW 18 INCHES. THE FUME HOOD MONITORS SHALL INDEX THE FUME HOOD EXHAUST AIR VALVES WHOSE SASHES ARE AT 18 INCHES AND BELOW TO MAINTAIN THE UNOCCUPIED FACE VELOCITY SETPOINT BASED ON MEASURED AIR VELOCITY. THE GENERAL EXHAUST AIR VALVES SHALL MODULATE AS NEEDED TO MAINTAIN THE UNOCCUPIED AIR CHANGE RATE. THE SUPPLY AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL FOR ROOM PRESSURIZATION. 6' FUME HOOD FUME HOOD MONITOR VERTICAL SASH POSITION INDICATOR HORIZONTAL SASH POSITION INDICATOR 6' FUME HOOD HORIZONTAL SASH POSITION INDICATOR VERTICAL SASH POSITION INDICATOR EXHAUST ΔP EAV-7 EXHAUST ΔP EAV-6 AI FLOW AI ALARM R DO OCCUPIED/ UNOCCUPIED COMMAND R DO DECOMMISSION FHV ANALOG ELECTRIC CONTROL WITH HOOD INTERFACE CARD AI SASH POSITION SAV-2 T RH-2SUPPLY AIR FROM MAU SAT SUMMER = 55 F SAT WINTER = 68 F ΔP AI AO F.L. ANALOG ELECTRIC CONTROL AI FLOW AI ALARM MOD AO SETPOINT COM MOD AOBACnet / ARCNET -OR- BACnet / MSTP AV: FLOW FEEDBACK (CFM) AV: POSITION FEEDBACK (%) AV: FLOW SETPOINT (CFM) CAV-2 EXHAUST FUME HOOD MONITOR AO AO AI AI AI FLOW AI ALARM R DO OCCUPIED/ UNOCCUPIED COMMAND R DO DECOMMISSION FHV ANALOG ELECTRIC CONTROL WITH HOOD INTERFACE CARD AI SASH POSITION AI AI AO AO EXHAUST ΔP EAV-8 AI FLOW AI ALARM ANALOG ELECTRIC CONTROL MOD AO SETPOINT VO BI T AV SETPOINT SA D AI VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 1:58:38 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 TJ CONTROLS SCHEMATIC LAB 573 AST CEV MI-602 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 LAB 573 POINTS LIST HIGH HOOD DENSITY TRACKING LABORATORY HARDWIRE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBI BO AI AO AV BV SCH TREND ALARM BACS EMCS DESCRIPTION TOTAL EXHAUST AIRFLOW (CFM)X X X TOTAL EXHAUST AIR SETPOINT (CFM)X X X LABORATORY AIR CHANGE RATE (ACPH)X X X ROOM AREA (SQUARE FEET)X X ROOM CEILING HEIGHT (FEET)X X FLOW OFFSET SETPOINT (CFM)X X FLOW OFFSET ACTUAL (CFM)X X SPACE TEMPERATURE SETPOINT, HEATING X X SPACE TEMPERATURE SETPOINT, COOLING X X SPACE TEMPERATURE SETPOINT X X X SPACE TEMPERATURE (RNET)X X X =+/-4°F FROM SETPOINT X SPACE SETPOINT ADJUSTMENT TRIM (RNET)X X SPACE OCCUPANCY, MINIMUM OCCUPANCY SETPOINT X X SPACE OCCUPANCY X X X EAV-6 FUME HOOD EXHAUST AIR VALVE AIR FLOW (CFM) X X X EAV-6 FUME HOOD EXHAUST AIR VALVE STATUS X X X VALVE COMMAND ≠ FEEDBACK (JAM) LOW DIFFERENTIAL PRESSURE (VIA SWITCH) X TRI-STATE ALARM EAV-6 FUME HOOD EXHAUST AIR VALVE OCC/UNOCC COMMAND X X TRI-STATE ALARM EAV-6 FUME HOOD VERTICAL SASH POSITION X X X SASH OPEN (18") FOR 24 CONTINUOUS HOURS OR MORE X EAV-6 FUME HOOD HORIZONTAL SASH POSITION X X X EAV-6 DECOMMISSIONING COMMAND X X X EAV-7 FUME HOOD EXHAUST AIR VALVE AIR FLOW (CFM) X X X EAV-7 FUME HOOD EXHAUST AIR VALVE STATUS X X X VALVE COMMAND ≠ FEEDBACK (JAM) LOW DIFFERENTIAL PRESSURE (VIA SWITCH) X TRI-STATE ALARM EAV-7 FUME HOOD EXHAUST AIR VALVE OCC/UNOCC COMMAND X X TRI-STATE ALARM EAV-7 FUME HOOD VERTICAL SASH POSITION X X X SASH OPEN (18") FOR 24 CONTINUOUS HOURS OR MORE X EAV-7 FUME HOOD HORIZONTAL SASH POSITION X X X EAV-7 DECOMMISSIONING COMMAND X X X EAV-8 EXHAUST AIR VALVE FLOW FEEDBACK (CFM)X X X EAV-8 EXHAUST AIR VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMXVALVE COMMAND ≠ FEEDBACK (JAM)X X LOW DIFFERENTIAL PRESSURE (VIA SWITCH)X EAV-8 EXHAUST AIR VALVE POSITION COMMAND (FLOW SETPOINT CFM)X X X EAV-8 EXHAUST AIR VALVE MINIMUM AIRFLOW SETPOINT (CFM)X X EAV-8 EXHAUST AIR VALVE MAXIMUM AIRFLOW SETPOINT (CFM)X X SAV-2 SUPPLY AIR VALVE FLOW FEEDBACK (CFM) X X X SAV-2 SUPPLY AIR VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMXVALVE COMMAND ≠ FEEDBACK (JAM)X X LOW DIFFERENTIAL PRESSURE (VIA SWITCH)X SAV-2 SUPPLY AIR VALVE POSITION COMMAND (FLOW SETPOINT CFM)X X X SAV-2 SUPPLY AIR VALVE MINIMUM AIRFLOW SETPOINT (CFM)X X SAV-2 SUPPLY AIR VALVE MAXIMUM AIRFLOW SETPOINT (CFM)X X RH-2 RE-HEAT COIL LEAVING AIR TEMPERATURE X X X SINGLE POINT SENSOR RH-2 RE-HEAT COIL LEAVING AIR TEMPERATURE HIGH LIMIT X X X SINGLE POINT SENSOR RH-2 RE-HEAT COIL VALVE POSITION X X X 5°F ΔT ACROSS COIL WITH VALVE COMMANDED CLOSED X FAIL FAST CAV-2 SUPPLY AIR VALVE FLOW FEEDBACK (CFM) X X X CAV-2 SUPPLY AIR VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMXVALVE COMMAND ≠ FEEDBACK (JAM)X X LOW DIFFERENTIAL PRESSURE (VIA SWITCH)X CAV-2 SUPPLY AIR VALVE POSITION COMMAND (FLOW SETPOINT CFM)X X X CAV-2 SUPPLY AIR VALVE MINIMUM AIRFLOW SETPOINT (CFM)X X CAV-2 SUPPLY AIR VALVE MAXIMUM AIRFLOW SETPOINT (CFM)X X WRITE-UP 580A POINTS LIST OFFICE SPACE HARDWIRE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBI BO AI AO AV BV SCH TREND ALARM BACS EMCS DESCRIPTION ZONE TEMPERATURE SETPOINT, HEATING & COOLING X x X ZONE TEMPERATURE SETPOINT TRIM X X X RNET ZONE TEMPERATURE X X X =+/-4°F FROM SETPOINT X RNET OCCUPANCY SENSOR X X X SINGLE POINT SENSOR VAV-1 SUPPLY AIR VAV BOX DAMPER POSITION COMMAND (CFM SETPOINT)X X X VAV-1 SUPPLY AIR VAV BOX AIRFLOW FEEDBACK (CFM)X X X 10% FLOW DEVIATION FROM SETPOINT X BACnet MSTP NETWORK POINT VAV-1 SUPPLY AIR VAV BOX AIRFLOW SETPOINT FEEDBACK (CFM)X X X BACnet MSTP NETWORK POINT VAV-1 SUPPLY AIR VAV BOX POSITION FEEDBACK (%)X X X VALVE COMMAND ≠ FEEDBACK X BACnet MSTP NETWORK POINT RH-3 RE-HEAT COIL LEAVING AIR TEMPERATURE X X X SINGLE POINT SENSOR RH-3 RE-HEAT COIL VALVE POSITION X X X 5°F ΔT ACROSS COIL WITH VALVE COMMANDED CLOSED X FAIL FAST SYSTEM DESCRIPTION: CONSTANT SUPPLY AIR VOLUME TERMINAL UNIT (CAV-3) DUCT MOUNTED RE-HEAT COIL (RH-3) GENERAL: 1. SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). 2. ALL SETPOINTS SHALL BE ADJUSTABLE. 3. THE SPACE SHALL BE CONTROLLED TO MAINTAIN SPACE TEMPERATURE BASED ON A CONSTANT SUPPLY AIR FLOW. 4. THE BAS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM FOR SEVEN DIFFERENT DAILY SCHEDULES PER WEEK. 5. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. 6. ZONE OCCUPANCY (OCCUPIED MODE) SCHEDULE: 6 AM TO 8 PM, MON - FRI. SETPOINTS: SPACE COOLING TEMPERATURE SETPOINTS: OCCUPIED: 75 °F +/- 1.5 °F OCCUPIED SETBACK: 75 °F +/- 3 °F UNOCCUPIED: 75 °F +/- 6 °F SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED: 70 °F +/- 1.5 °F OCCUPIED SETBACK: 70 °F +/- 3 °F UNOCCUPIED: 70 °F +/- 6 °F ZONE TEMPERATURE CONTROL: TEMPERATURE SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF PROGRAMMED SCHEDULE AND STATUS OF SPACE VACANCY SENSORS. HEATING MODE: SHOULD THE SPACE TEMPERATURE FALL BELOW SETPOINT, THE HEATING SETPOINT SHALL BE MAINTAINED BY MODULATING THE RE-HEAT COIL CONTROL VALVE. SCHEDULED OCCUPIED PERIOD - VACANCY SENSOR ACTIVE: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. SPACE SHALL BE MAINTAINED AT THE OCCUPIED HEATING TEMPERATURE SETPOINT. SCHEDULED OCCUPIED PERIOD - VACANCY SENSOR INACTIVE: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED SETBACK MODE. SPACE SHALL BE MAINTAINED AT THE OCCUPIED SETBACK HEATING TEMPERATURE SETPOINT. SCHEDULED UNOCCUPIED PERIOD - VACANCY SENSOR ACTIVE:IF THE SPACE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. SPACE SHALL BE MAINTAINED AT THE OCCUPIED HEATING TEMPERATURE SETPOINT. WHEN THE SPACE BECOMES UNOCCUPIED AGAIN DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX BACK TO UNOCCUPIED MODE. SCHEDULED UNOCCUPIED PERIOD - VACANCY SENSOR INACTIVE: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO UNOCCUPIED MODE. SPACE SHALL BE MAINTAINED AT THE UNOCCUPIED HEATING TEMPERATURE SETPOINT. COOLING MODE: SCHEDULED OCCUPIED PERIOD - OCCUPANCY SENSOR ACTIVE:IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. SPACE SHALL BE MAINTAINED AT THE OCCUPIED COOLING TEMPERATURE SETPOINT. IF THE SPACE TEMPERATURE DROPS BELOW THE COOLING SETPOINT THE CONTROL VALVE ON THE RE-HEAT COIL SHALL MODULATE OPEN TO MAINTAIN SPACE COOLING SETPOINT. THE SPACE SHALL BE PROVIDED WITH CONSTANT AIR FLOW AS INDICATED ON THE PLANS AT ALL TIME. SCHEDULED OCCUPIED PERIOD - OCCUPANCY SENSOR INACTIVE: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED SETBACK MODE. SPACE SHALL BE MAINTAINED AT THE OCCUPIED SETBACK COOLING TEMPERATURE SETPOINT. THE SPACE TEMPERATURE DROPS BELOW THE COOLING TEMPERATURE SETPOINT, THE RE-HEAT COIL CONTROL VALVE SHALL MODULATE OPEN, TO MAINTAIN THE UNOCCUPIED SPACE TEMPERATURE SETPOINT. SCHEDULED UNOCCUPIED PERIOD - VACANCY SENSOR ACTIVE:IF THE SPACE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. SPACE SHALL BE MAINTAINED AT THE OCCUPIED COOLING TEMPERATURE SETPOINT. WHEN THE SPACE BECOMES UNOCCUPIED AGAIN DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX BACK TO UNOCCUPIED MODE. THE SPACE TEMPERATURE DROPS BELOW THE COOLING TEMPERATURE SETPOINT, THE RE-HEAT COIL CONTROL VALVE SHALL MODULATE OPEN, TO MAINTAIN THE OCCUPIED SPACE TEMPERATURE SETPOINT. SCHEDULED UNOCCUPIED PERIOD - VACANCY SENSOR INACTIVE: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO UNOCCUPIED MODE. SPACE SHALL BE MAINTAINED AT THE UNOCCUPIED COOLING TEMPERATURE SETPOINT. THE SPACE TEMPERATURE DROPS BELOW THE COOLING TEMPERATURE SETPOINT, THE RE-HEAT COIL CONTROL VALVE SHALL MODULATE OPEN, TO MAINTAIN THE UNOCCUPIED SPACE TEMPERATURE SETPOINT. T AI COM MOD AOBACnet / ARCNET -OR- BACnet / MSTP AV: FLOW FEEDBACK (CFM) AV: POSITION FEEDBACK (%) AV: FLOW SETPOINT (CFM) CAV-3 SUPPLY VO BI T AV SETPOINT SA D AIRH-3AO F.L. SUPPLY AIR FROM MAU SAT SUMMER = 55 F SAT WINTER = 68 F WRITE-UP 580A VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 1:58:39 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 TJ LAB 580 CONTROL SCHEMATIC AND LAB 573 POINTS LIST AST CEV MI-603 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 ABOVE ABV ABOVE FINISHED FLOOR AFF ACCESS DOOR AD ACID RESISTANT WASTE ARW ACID VENT AV ALARM ALM AQUASTAT AQST ARCHITECT(URAL)ARCH ARCHITECT/ENGINEER A/E AREA DRAIN ADRN AUTOMATIC AUTO AUTOMATIC AIR VENT AAV BACK WATER VALVE BWV BACKFLOW PREVENTER BFP BALANCING VALVE BAL V BALL VALVE BV BATHTUB BT BELOW BLW BELOW FINISHED FLOOR BFF BRAKE HORSEPOWER BHP BRITISH THERMAL UNIT BTU BRITISH THERMAL UNITS (1000) PER HOUR MBH BRITISH THERMAL UNITS PER HOUR BTUH BUILDING BLDG BUTTERFLY VALVE BFV BY OWNER BO CATCH BASIN CB CHECK VALVE CKVA CIRCULATING PUMP CP CLEAN OUT CO COLD WATER CW COMPRESSED AIR CA COMPRESSOR COMP CONDENSATE DRAIN CD CONNECTION CONN CONTRACT LIMIT LINE CLL CONTRACTOR CONTR CONTROL VALVE CV CYCLE CY DECK PLATE CLEAN-OUT DPCO DEIONIZED WATER DIW DETAIL DTL DISTILLED WATER DI DIAMETER DIA DISHWASHER DWSH DOWN DN DRAIN DR DRAWING DWG DRINKING FOUNTAIN DF DRY WELL DRW ELECTRIC(AL)ELEC ELECTRIC WATER COOLER EWC ELECTRIC WATER HEATER EWH EMERGENCY SHOWER EMSHR EMERGENCY EYEWASH EMEW ENGINEER ENGR ENTERING WATER TEMPERATURE EWT EQUIPMENT EQPM EXISTING (E) EXPANSION TANK ET EXTERIOR EXT FACTORY MUTUAL FM FEET (FOOT)FT FIRE PROTECTION FP FLOOR CLEANOUT FCO FLOOR DRAIN FD FLOOR SINK FS FLOW SWITCH FS FULL LOAD AMPS FLA GAGE (GAUGE)GA GALLON GAL GALLONS PER DAY GPD GALLONS PER HOUR GPH GALLONS PER MINUTE GPM GAS G GATE VALVE GV GREASE TRAP GT GREASE INTERCEPTOR GI GENERAL CONTRACTOR GC HAND SINK HSNK HERTZ HZ HIGH PRESSURE GAS HPG HOSE BIBB HB HORSEPOWER HP HOT WATER HW INCH(ES)IN INCHES WATER COLUMN IN WC INDIRECT WASTE IW INSIDE DIAMETER ID INSULATION INSUL INVERT INV IRON PIPE SIZE IPS KILOWATT KW KILOWATT HOUR KWH LAVATORY LAV LEAVING WATER TEMPERATURE LWT LIQUEFIED PERTOLEUM GAS LPG LOCKED ROTOR AMPS LRA MANHOLE MH MANUFACTURER MFR MATCHLINE ML MECHANICAL MECH METER M MIXING VALVE MV MINIMUM CIRCUIT AMPACITY MCA MOP SINK MSNK MOTOR CONTROL CENTER MCC NATURAL GAS NG NITROGEN N NON-FREEZE HOSE BIBB NFHB NORMALLY CLOSED NC NORMALLY OPEN NO NOT TO SCALE NTS OUTSIDE DIAMETER OD OVERFLOW ROOF DRAIN ORD OXYGEN OXY PHASE PH PLUMBING PLBG PNEUMATIC PNEU POUNDS PER SQUARE INCH PSI POUNDS PER SQUARE INCH ABSOLUTE PSIA POUNDS PER SQUARE INCH GAGE PSIG PRESSURE DROP PD PRESSURE REDUCING VALVE PRV PRESSURE TEMPERATURE RELIEF VALVE PTRV PROJECT PROJ PUMP P PUMP DISCHARGE LINE PD RAIN WATER LEADER RWL REDUCED PRESSURE ZONE RPZ REQUIRED REQD REVOLUTIONS PER MINUTE RPM RISER R ROOF DRAIN RD RUNNING LOAD AMPS RLA SANITARY SAN SANITARY SEWER SS SCHEDULE SCHED SECTION SECT SERVICE SINK SS SHOWER SHR SINK SNK SLEEVE SLV SPECIFICATIONS SPEC SQUARE FOOT SQ FT SQUARE INCH SQ IN STAINLESS STEEL SS STAND PIPE SP STORAGE TANK ST STORM DRAIN ST TEMPERATURE TEMP THERMOSTATIC MIXING VALVE TMV TRAP T TRAP PRIMER TP TRENCH DRAIN TD TYPICAL TYP UNLESS OTHERWISE NOTED UON UTILITY UTIL URINAL URN VACUUM VAC VACUUM BREAKER VB VALVE V VARIABLE FREQUENCY DRIVE VFD VEMT (SANITARY)V VENT TROUGH ROOF VTR VERIFY IN FIELD VIF VOLT V WALL HYDRANT WH WALL CLEAN-OUT WCO WATER CLOSET WC WATER HAMMER ARRESTOR WHA WATER HEATER WH WIRE MESH SCREEN WMS FIRE PROTECTION ABBREVIATIONS AD WHA P M PT P FD HB WH X P D CO S OR OR WH PIPING SYMBOLS -VALVES AND SPECIALTIES BALL VALVE PLUG VALVE SHUT-OFF VALVE IN RISER BALANCING VALVE MIXING VALVE CHECK VALVE ISOLATION VALVE SOLENOID VALVE STRAINER GLOBE VALVE PRESSURE REDUCING VALVE RELIEF VALVE X INDICATES P - PRESSURE T - TEMPERATURE PT - COMBINATION (PRESS./TEMP.) BACKFLOW PREVENTER (BFP) BRANCH CONNECTION - BOTTOM BRANCH CONNECTION - TOP ELBOW TURNED DOWN ELBOW TURNED UP CAP REDUCER CLEANOUT (FLOOR/WALL) WALL HYDRANT HOSE BIBB FLOOR DRAIN ROOF DRAIN UNION FLEXIBLE CONNECTOR DIRECTION OF FLOW DIRECTION OF DOWNWARD PITCH PRESSURE/TEMPERATURE TAP PRESSURE GAUGE THERMOMETER CIRCULATING PUMP METER WATER HAMMER ARRESTOR ACCESS DOOR DECK PLATE/YARD CLEAN-OUT POINT OF CONNECTION POINT OF DISCONNECTION EXTENT OF DEMOLITION HB FIRE PROTECTION SYMBOLES -VALVES AND SPECIALTIES FIRE PROTECTION NOTES A. THE AUTOMATIC SPRINKLER SYSTEMS WITHIN THIS FACILITY SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA-13. ALL FIRE SUPPRESSION SYSTEMS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE FIRE CODE OF NEW YORK STATE, CORNELL UNIVERSITY DESIGN STANDARDS AND APPLICABLE FM GLOBAL DATA SHEETS B. ALL PIPE SIZES AND HYDRAULIC NODES SHOWN ARE FOR REFERENCE ONLY. FIRE PROTECTION CONTRACTOR TO PERFORM HYDRAULIC CALCULATIONS TO DETERMINE FINAL PIPE SIZES. C. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES AND COMPLY WITH ALL OBSTRUCTION REQUIREMENTS AS DESCRIBED WITHIN NFPA-13. D. THE CONTRACTOR SHALL VISIT THE SITE AND REVIEW EXISTING CONDITIONS AND MAKE ALLOWANCE FOR ANY EXISTING CONDITIONS PRIOR TO SUBMITTING BID. E. ALL COMPONENTS OF AUTOMATIC SPRINKLER SYSTEM SHALL BE LISTED FOR USE IN FIRE SUPPRESSION SYSTEMS AND BE LISTED BY UNDERWRITERS LABORATORIES (UL) AND FM GLOBAL (FM). F. ALL CHECK VALVES SHALL HAVE REMOVABLE FACE PLATES FOR INSPECTION AND MAINTENANCE. GENERAL NOTES A. THIS LEGEND IS FOR THE CONTRACTOR'S REFERENCE ONLY. NOT ALL SYMBOLS AND/OR ABBREVIATIONS MAY APPLY TO THIS PARTICULAR PROJECT. ANY ADDITIONS OR OMISSIONS FROM THIS LEGEND SHEET DOES NOT IMPLY INCLUSION AND/OR EXCLUSION OF ANY PARTICULAR ITEMS FROM THE PROJECT. B. THE PLANS ARE DIAGRAMMATIC AND INDICATE ONLY THE SIZE AND GENERAL ARRANGEMENT OF PIPING/DUCTWORK AND EQUIPMENT. EXACT LOCATION OF ALL ELEMENTS SHALL BE DETERMINED AS WORK PROGRESSES, IN COOPERATION AND COORDINATION WITH THE WORK OF ALL TRADES. THEY ARE NOT INTENDED TO SHOW EVERY ITEM OF WORK OR MINOR PIECE OF EQUIPMENT. CONTRACTOR SHALL FURNISH AND INSTALL WITHOUT ADDITIONAL REMUNERATION ANY COMPONENT NECESSARY TO COMPLETE THE SYSTEM IN ACCORDANCE WITH THE BEST PRACTICE OF THE TRADE. C. ITEMS OF WORK OR EQUIPMENT SHOWN ON THE DRAWINGS ONLY, OR CALLED FOR IN THE SPECIFICATIONS ONLY, SHALL BE FURNISHED AND INSTALLED IN THE SAME MANNER AS IF THEY APPEARED ON BOTH THE DRAWINGS AND IN THE SPECIFICATIONS. D. DRAWINGS DO NOT INDICATE ALL OFFSETS, CHANGES IN ELEVATIONS, ETC. WHICH MAY BE REQUIRED. THE CONTRACTOR SHALL MAKE SUCH CHANGES IN PIPING/DUCTWORK AND LOCATION OF EQUIPMENT, ETC. TO ACCOMMODATE WORK, OBSTACLES, AND WORK OF OTHER TRADES/CONTRACTORS. E. INSTALL EQUIPMENT AND PIPING/DUCTWORK TO AVOID INTERFERENCE WITH THE OPERATION, SERVICE, AND MAINTENANCE OF EQUIPMENT. F. ALL COSTS FOR CUTTING, PATCHING AND PAINTING OF EXISTING WALLS, CEILINGS AND FLOORS TO ACCOMMODATE THE INSTALLATION OF WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR UNLESS INDICATED OTHERWISE. MATERIALS FOR THE RESTORATION OF EXISTING SURFACES SHALL MATCH THE EXISTING SURFACES. G. PIPES AND/OR DUCTS PENETRATING FIRE WALLS AND FLOORS SHALL BE FIRESTOPPED USING UL APPROVED MATERIALS. REFER TO THE ARCHITECTURAL DRAWINGS FOR FIRE WALL AND FLOOR LOCATIONS. H. ALL PHYSICAL ATTRIBUTES OF EQUIPMENT AND DEVICES ARE BASED ON THOSE MANUFACTURERS LISTED IN THE SPECIFICATIONS AND/OR THE EQUIPMENT SCHEDULES. THE RESPECTIVE CONTRACTORS ARE RESPONSIBLE FOR ALL CHANGES BROUGHT ABOUT BY THE USE OF ITEMS BY OTHER MANUFACTURERS IF THOSE ITEMS DO NOT MATCH THE PHYSICAL ATTRIBUTES OF THE MANUFACTURERS LISTED. FLOW TEST INFORMATION A.STATIC PRESSURE: 139 PSI B.RESIDUAL PRESSURE: 116 PSI C. FLOW: 1,125 GPM GENERAL DEMOLITION NOTES A. THE DEMOLITION PLANS AND NOTES HAVE BEEN PREPARED TO ASSIST THE CONTRACTORS IN IDENTIFYING THE AREAS AND ITEMS OF DEMOLITION AND RENOVATION ASSOCIATED WITH THIS PROJECT. THE INFORMATION PROVIDED IS NOT MEANT TO BE ALL- INCLUSIVE IN TERMS OF LISTING EACH AND EVERY SPECIFIC TASK TO BE PERFORMED. EACH CONTRACTOR WILL THOROUGHLY EXAMINE ALL CONTRACT DOCUMENTS PRIOR TO PERFORMING ANY WORK. B. DEMOLITION WORK INCLUDES, BUT IS NOT LIMITED TO, THE ITEMS INDICATED ON THE DEMOLITION DRAWINGS AND DESCRIBED IN THE DEMOLITION NOTES. THE EXTENT OF THE DEMOLITION WORK WILL INCLUDE ALL WORK REQUIRED TO COMPLETE THE PROJECT AND ENSURE WHETHER OR NOT THE WORK IS INDICATED ON THE DRAWINGS. C. EACH CONTRACTOR SHALL THOROUGHLY EXAMINE AND VERIFY ALL EXISTING CONDITIONS BEFORE PERFORMING ANY WORK AND IMMEDIATELY NOTIFY THE OWNER, IN WRITING, OF ANY DISCREPANCIES WITH THE DRAWINGS. D. ALL ITEMS NOTED TO BE REMOVED TO BE DISPOSED OF OFF-SITE BY RESPECTIVE CONTRACTORS, UNLESS NOTED OTHERWISE. WHERE INDICATED ON THE DRAWINGS AND/OR IN THE NOTES AS SALVAGE, THE CONTRACTOR SHALL CAREFULLY REMOVE INDICATED ITEMS AND STORE THEM WHERE DIRECTED BY THE OWNER. E. THE OWNER HAS THE OPTION TO RETAIN POSSESSION OF ANY REMOVED MATERIALS OR EQUIPMENT. ALL SUCH ITEMS SHALL BE CAREFULLY REMOVED AND STORED AT THE SITE BY THE CONTRACTOR WHERE DIRECTED BY THE OWNER. ANY MATERIALS OR EQUIPMENT NOT RETAINED BY THE OWNER WILL BECOME THE PROPERTY OF THE CONTRACTOR AND PROMPTLY REMOVED FROM SITE. F. REFER TO ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR DEMOLITION WORK BY RESPECTIVE CONTRACTORS. EACH CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION ASSOCIATED WITH HIS CONTRACT AND SCOPE OF WORK. EACH CONTRACTOR IS RESPONSIBLE TO PATCH AND/OR REPAIR ANY AND ALL CONSTRUCTION AFFECTED BY HIS DEMOLITION. THE EXTENT OF PATCH AND REPAIR SHALL BE AS REQUIRED TO RECEIVE THE SCHEDULED NEW WORK. ALL CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK WITH OTHER CONTRACTORS BEFORE PERFORMING ANY WORK. G. ALL PATCH AND REPAIR WORK SHALL BE PERFORMED USING MATERIALS THAT MATCH THE EXISTING ADJACENT CONSTRUCTION. WHERE PATCHING EXISTING MASONRY WALLS OR INFILLING BETWEEN WALLS WITH MASONRY TO MATCH EXISTING, "TOOTH-IN" NEW MASONRY TO EXISTING. H. EACH CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING CONSTRUCTION SCHEDULED TO REMAIN. EACH CONTRACTOR IS RESPONSIBLE TO PATCH AND/OR REPAIR ANY AND ALL CONSTRUCTION AFFECTED BY THEIR DEMOLITION. EACH CONTRACTOR SHALL PATCH (SUBSTRATE AND FINISHED SURFACES) ANY EXISTING FINISHES AFFECTED BY THEIR RESPECTIVE WORK. I. EXISTING CONDITIONS INDICATED ARE OBTAINED FROM AVAILABLE SOURCES (EXISTING DRAWINGS, FIELD SURVEYS, ETC.) AND ARE NOT GUARANTEED TO BE TRUE AND EXACT. CONTRACTOR(S) SHALL FIELD VERIFY EXISTING CONDITIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE AFFECTED PORTION OF THE WORK. J. REMOVAL IN ITS ENTIRETY INCLUDES HANGERS, ELECTRICAL, CONTROLS, ETC., TO LEAVE A LIKE NEW OR MATCHING EXISTING CONDITION. FIRE PROTECTION SYMBOLS - VALVES AND SPECIALTIES UPRIGHT SPRINKLER HEAD - 3/4" NPT, 8.0 K, ORDINARY TEMPERATURE FLOW SWITCH LISTED INDICATING VALVE WITH TAMPER SWITCH CHROME PLATED SEMI-RECESSED PENDANT SPRINKLER HEAD, UNLESS NOTED OTHERWISE - 3/4" NPT, 8.0 K, ORDINARY TEMPERATURE VALUES FROM FIRE PUMP DISCHARGE VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 12:11:52 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 AST FIRE PROTECTION SYMBOLS, NOTES & ABBREVIATIONS AST LY FP-000 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 FEFEFE 123456789101112131415161718192021 A B C D E P CONNECT TO EXISTING DRAIN RISER 4" FLOOR CONTROL STATION 1" 1-1/4" 1-1/4" 1" 1" 1-1/4"1-1/4" 4"4"4" 4"4"1"1-1/4"1"1-1/2"1" PROVIDE FULL PORT BALL VALVE FOR FLUSHING. (TYP.) SEE GENERAL NOTE 1 BELOW PROVIDE FULL PORT BALL VALVE ON ALL BRANCH LINES FOR FLUSHING. (TYP.) SEE GENERAL NOTE 1 BELOW PROVIDE FLOW ALARM SWITCH MANUFACTURER: POTTER MODEL: AUTO TEST VSR-AT VANE TYPE WITH WATER FLOW ALARM SWITCH WITH ELECTRIC RETARD AND AUTO TEST FEATURE PROVIDE HEADS BELOW OBSTRUCTIONS AND SPRING UP HEADS IN OPEN CEILING POCKETS. (TYP.)1 1/2"2"2"OFFSET UP TO EL. 9'-6" 1"1-1/4"1"1"1-1/4"1"1"1-1/4"1-1/4"1-1/4"2"2"2"1 1/2"1 1/2"1 1/2"1 1/2"2" 2"1 1/2"1 1/2"1 1/2"PROVIDE SPRINKLER HEAD UNDER INTERMEDIATE LANDING BETWEEN FLOORS 4 AND 5. PROVIDE SPRINKLER HEAD UNDER INTERMEDIATE LANDING BETWEEN FLOORS 4 AND 5. INSTALL PIPING TIGHT TO BOTTOM OF BEAMS AND SPRIG HEADS UP TO DECK (TYP) SPRINKLER HEADS FOR COVERAGE BELOW DUCT. TYP. SPRINKLER HEADS FOR COVERAGE BELOW DUCT. (TYP) OFFICE 582A LAB 572 OFFICE 560A WRITE-UP 580 STAIR 500SB MECH 500UD LAB 573 OFFICE 582 WRITE-UP 562A MENS' 500TA ELEVATOR 500EAMECH 500UA STAIR 500SA LAB 570 WRITE-UP 570A WRITE-UP 572A CONFERENCE 561 OFFICE 560 WRITE-UP 563 LAB 565 MECH 500UE LAB 571 MECH 500UB ELEVATOR 500EB MECH 500UC WOMEN'S 500TB Room 550J Room 569 CORRIDOR 500CA LAB 580A CORRIDOR 500CA LAB 575 VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 12:11:55 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 AST OVERALL FIFTH FLOOR PLAN - FIRE PROTECTION AST LY FP-101 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 1/8" = 1'-0" 1 OVERALL FIFTH FLOOR PLAN - FIRE PROTECTION NORTHFIRE PROTECTION PHASING: COORDINATE WITH OWNER TO PHASE INSTALLATION OF SPRINKLERS TO MINIMIZE DISRUPTION AND DOWN TIME IN EACH SPACE. PHASE WORK IN LABORATORY SPACES SEPARATELY AND COMPLETE IN TIMELY DURATIONS AS FOLLOWS: - LAB 562 AND WRITE-UP 562A - 2 DAYS - LAB 565 AND WRITE-UP 563 - 2 DAYS - LAB 570 AND WRITE-UP 570A - 2 DAYS - LAB 571 - 2 DAYS - LAB 572 AND WRITE-UP 572A - 2 DAYS CONSTRUCT TEMPORARY PROTECTION OVER EXISTING GLASS MANIFOLD ASSEMBLIES IN THE LAB SPACES DURING WORK TO PROTECT FROM DAMAGE. GENERAL NOTES: 1. FLUSHING FULL-PORT BALL VALVES SHALL BE PROVIDED ON SPRINKLER MAINS, CROSS- MAINS, BRANCH LINES AND RUN OUTS OF NEW SPRINKLER SYSTEMS (WET AND DRY), TO FACILITATE ANY FUTURE PERIODIC INTERNAL INSPECTIONS, OBSTRUCTION INVESTIGATIONS AND AS-NEEDED FLUSHING WORK. VALVES SHALL BE SIZED BY THE ENGINEER OF RECORD AND PER NFPA 25, IN ORDER TO OBTAIN THE NFPA REQUIRED MINIMUM VELOCITY OF 10FT/S FOR ANY GIVEN PIPE SIZE. AS AN ALTERNATIVE TO THE HYDRAULIC CALCULATION VALVE SIZING METHOD, THE FOLLOWING SIZING RULES CAN BE APPLIED: • 1-INCH THRU 2 ½-INCH PIPE: LINE-SIZE FULL-PORT BALL VALVE • 3-INCH PIPE: ONE (1) 2 ½-INCH BALL VALVE • 4-INCH PIPE: TWO (2) 2 ½-INCH BALL VALVES • 6-INCH PIPE: THREE (3) 2 ½-INCH BALL VALVES • 8-INCH PIPE: FOUR (4) 2 ½-INCH BALL VALVES 2. PROVIDE A HYDRAULIC DESIGN DENSITY OF 0.20 gpm/sq.ft OVER THE REMOTE 2500 SQFT. AREA. NFPA-13 ORD. HAZ. GRII AND FM GLOBAL HC-2. II 125 TEST 50 75100 I 25 150 175200225250 AGF MANUFACTURING, INC.MODEL 7500 275 300 WATERL I S T E DP R E S S U R E G A U G E F O RF I R E P R O T E C T I O NS E R V I C E2 3 3 H 3 1 / 2 " P 1 5 9 0E X 4 0 7 A P P R O V E D I I III I III I II I I I III I III I II II III I III I III IIIIII I III I IDRAIN OFFIIIII II I I 400 III II 1800 II II600 I1600I III III II II I I II II III II I200I 2000 IIII 1400II800IIIIIIIIIIIIIIIIIIIIIIIIII I IIIIIIIIIIIIIIIIIIIII SUSPENDED CEILING PENDENT ESCUTCHEON PLATE 1"BRANCH LINE I-BEAM OR BAR JOIST PIPE GALV. AUTO GRIP ALL THREAD ROD BEAM CLAMP * SEE NFPA-13 FOR HANGER SIZE AND SPACING I-BEAM OR BAR JOIST ALL THREAD ROD BEAM CLAMP * SEE NFPA-13 FOR HANGER SIZE AND SPACING GALV. AUTO GRIP PIPE GALV. AUTO GRIP 1" MIN./12" MAX. GALV. AUTO GRIP SUPPORT FROM JOIST OR DECK ABOVE ALL OUTLETS IN BRANCH PIPING SHOULD BE A MIN. OF 1" UPRIGHT SPRINKLER TEE PIPE NIPPLE BRANCH LINE UNDERSIDE OF CEILING REDUCER 20'-0" 7'-0" AIRFLOW UNIT HEATER HEATER ZONE HIGH TEMPERATURE ZONE INTERMEDIATE TEMPERATURE ZONE PROVIDE FLOW ALARM SWITCH MANUFACTURER: POTTER MODEL: AUTO TEST VSR-AT VANE TYPE WITH WATER FLOW ALARM SWITCH WITH ELECTRIC RETARD AND AUTO TEST FEATURE TO SPRINKLERS SUPPLY RISER TO DRAIN CONTROL VALVE W/ SUPERVISORY SWITCH INSPECTORS TEST AND DRAIN ASSEMBLY W/RELIEF VALVE, SIGHT GLASS, AND PRESSURE GAUGE VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 12:11:56 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 AST FIRE PROTECTION DETAILS AST LY FP-500 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 NO SCALEATYPICAL PENDENT SPRINKLER HEAD DETAIL NO SCALE D TOP BEAM CLAMP HANGER NO SCALE E TRAPEZE HANGER NO SCALEBTYPICAL UPRIGHT SPRINKLER HEAD DETAIL NO SCALE C UNIT HEATER ZONE NO SCALE F INSPECT TEST AND DRAIN ASSEMBLY These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 12:11:56 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 CWC PLUMBING SYMBOLS, NOTES AND ABBREVIATIONS AST MSM P-000 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 ABOVE ABV ABOVE FINISHED FLOOR AFF ACCESS DOOR AD ACID RESISTANT WASTE ARW ACID VENT AV ACID WASTE AW ALARM ALM AQUASTAT AQST ARCHITECT(URAL) ARCH ARCHITECT/ENGINEER A/E AREA DRAIN ADRN AUTOMATIC AUTO AUTOMATIC AIR VENT AAV BACK WATER VALVE BWV BACKFLOW PREVENTER BFP BALANCING VALVE BAL V BALL VALVE BV BATHTUB BT BELOW BLW BELOW FINISHED FLOOR BFF BRAKE HORSEPOWER BHP BRITISH THERMAL UNIT BTU BRITISH THERMAL UNITS (1000) PER HOUR MBH BRITISH THERMAL UNITS PER HOUR BTUH BUILDING BLDG BUTTERFLY VALVE BFV BY OWNER BO CATCH BASIN CB CHECK VALVE CKVA CIRCULATING PUMP CP CLEAN OUT CO COMPRESSED AIR CA COMPRESSOR COMP CONDENSATE DRAIN CD CONNECTION CONN CONTRACT LIMIT LINE CLL CONTRACTOR CONTR CONTROL VALVE CV CYCLE CY DECK PLATE CLEAN-OUT DPCO DEIONIZED WATER DIW DETAIL DTL DISTILLED WATER DW DIAMETER DIA DISHWASHER DWSH DOMESTIC COLD WATER SUPPLY CW DOMESTIC HOT WATER SUPPLY DHW DOMESTIC HOT WATER RECIRC DHWRC DOWN DN DRAIN DR DRAWING DWG DRINKING FOUNTAIN DF DRY WELL DRW ELECTRIC(AL) ELEC ELECTRIC WATER COOLER EWC ELECTRIC WATER HEATER EWH EMERGENCY SHOWER EMSHR EMERGENCY EYEWASH EMEW ENGINEER ENGR ENTERING WATER TEMPERATURE EWT EQUIPMENT EQPM EXISTING (E) EXPANSION TANK ET EXTERIOR EXT FACTORY MUTUAL FM FEET (FOOT)FT FIRE PROTECTION FP FLOOR CLEANOUT FCO FLOOR DRAIN FD FLOOR SINK FS FLOW SWITCH FS FORCED AIR FURNACE FAF FULL LOAD AMPS FLA GAGE (GAUGE) GA GALLON GAL GALLONS PER DAY GPD GALLONS PER HOUR GPH GALLONS PER MINUTE GPM GAS G GATE VALVE GV GREASE TRAP GT GREASE INTERCEPTOR GI GENERAL CONTRACTOR GC HUB DRAIN HD HAND SINK HSNK HERTZ HZ HIGH PRESSURE GAS HPG HOSE BIBB HB HORSEPOWER HP INCH(ES)IN INCHES WATER COLUMN IN WC INDIRECT WASTE IW INSIDE DIAMETER ID INSULATION INSUL INVERT INV IRON PIPE SIZE IPS KILOWATT KW KILOWATT HOUR KWH LAVATORY LAV LEAVING WATER TEMPERATURE LWT LIQUEFIED PERTOLEUM GAS LPG LOCKED ROTOR AMPS LRA MANHOLE MH MANUFACTURER MFR MATCHLINE ML MECHANICAL MECH METER M MIXING VALVE MV MINIMUM CIRCUIT AMPACITY MCA MOP SINK MSNK MOTOR CONTROL CENTER MCC NATURAL GAS NG NITROGEN N2 NON-FREEZE HOSE BIBB NFHB NORMALLY CLOSED NC NORMALLY OPEN NO NOT TO SCALE NTS OUTSIDE DIAMETER OD OVERFLOW ROOF DRAIN ORD OXYGEN OXY PHASE PH PLUMBING PLBG PNEUMATIC PNEU POUNDS PER SQUARE INCH PSI POUNDS PER SQUARE INCH ABSOLUTE PSIA POUNDS PER SQUARE INCH GAGE PSIG PRESSURE DROP PD PRESSURE REDUCING VALVE PRV PRESSURE TEMPERATURE RELIEF VALVE PTRV PROJECT PROJ PUMP P PUMP DISCHARGE LINE PD RAIN WATER LEADER RWL REDUCED PRESSURE ZONE RPZ REQUIRED REQD REVOLUTIONS PER MINUTE RPM RISER R ROOF DRAIN RD RUNNING LOAD AMPS RLA SANITARY SAN SANITARY SEWER SS SCHEDULE SCHED SECTION SECT SERVICE SINK SS SHOWER SHR SINK SNK SLEEVE SLV SPECIFICATIONS SPEC SQUARE FOOT SQ FT SQUARE INCH SQ IN STAINLESS STEEL SS STAND PIPE SP STORAGE TANK ST STORM DRAIN SD TEMPERATURE TEMP THERMOSTATIC MIXING VALVE TMV TRAP T TRAP PRIMER TP TRENCH DRAIN TD TYPICAL TYP UNLESS OTHERWISE NOTED UON UTILITY UTIL URINAL URN VACUUM VAC VACUUM BREAKER VB VALVE V VARIABLE FREQUENCY DRIVE VFD VEMT (SANITARY) V VENT TROUGH ROOF VTR VERIFY IN FIELD VIF VOLT V WALL HYDRANT WH WALL CLEAN-OUT WCO WATER CLOSET WC WATER HAMMER ARRESTOR WHA WATER HEATER WH WIRE MESH SCREEN WMS A.CONTRACTORS ARE URGED TO INSPECT THE SITE BEFORE SUBMITTING A BID PROPOSAL TO ENSURE KNOWLEDGE OF PROJECT REQUIREMENTS AND SITE CONDITIONS. IF NO CLARIFICATION IS REQUESTED, IT WILL BE CONSIDERED THAT THE CONTRACTORS ARE IN FULL UNDERSTANDING OF PROJECT REQUIREMENTS. B.PROVIDE LABOR, SUPERVISION, EQUIPMENT, MATERIALS, AND SERVICES REQUIRED FOR THE COMPLETE INSTALLATION OF THIS WORK IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE, AND LOCAL CODES, AUTHORITIES HAVING JURISDICTION, AND STANDARDS INCLUDING BUT NOT LIMITED TO, ASHRAE, IBC, NEC, AND NFPA. C.NOTHING CONTAINED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS SHALL BE CONSTRUED TO BE IN CONFLICT WITH ANY STATE OR LOCAL CODES, ORDINANCES OR REGULATIONS. D.NOTHING CONTAINED WITHIN THESE NOTES SHALL SUPERCEDE THE REQUIREMENTS OF THE SPECIFICATIONS. E.THE USE OF THE WORD "PROVIDE" SHALL MEAN TO FURNISH, INSTALL AND CONNECT, READY TO USE. F.THE USE OF THE WORD "FURNISH" SHALL MEAN TO PROCURE AND DELIVER TO THE SITE. G.THE USE OF THE WORD "INSTALL" SHALL MEAN TO PHYSICALLY PLACE INTO SERVICE AND CONNECT, READY TO USE. H.EQUIPMENT AND MATERIALS SHALL BE INSTALLED BY SKILLED TRADESMEN, FAMILIAR WITH THE COMPONENTS TO BE INSTALLED, AND IN ACCORDANCE WITH BEST PRACTICES OF THE INDUSTRY. I.BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS, AND ACCESSORIES THAT MAY BE REQUIRED. THIS CONTRACTOR SHALL CAREFULLY EXAMINE THE ARCHITECTURAL; STRUCTURAL; HEATING, VENTILATING AND AIR-CONDITIONING; ELECTRICAL; PLUMBING; AND OTHER PROJECT DOCUMENTS AS MAY BE NECESSARY FOR PROPER OPERATION OR INSTALLATION AND SHALL PROVIDE OFFSETS, FITTINGS, AND ACCESSORIES TO MEET PROJECT CONDITIONS. J.DISCREPANCIES BETWEEN DRAWINGS OR BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE REPORTED TO THE DESIGN PROFESSIONAL IN WRITING. OBTAIN WRITTEN INSTRUCTIONS FROM PROFESSIONAL AS TO THE MANNER IN WHICH TO PROCEED. NO DEPARTURES FROM THE PROJECT DOCUMENTS SHALL BE MADE WITHOUT PRIOR WRITTEN ACCEPTANCE BY THE PROFESSIONAL. K.DIMENSIONS, CLEARANCES, AND LOCATIONS OF EQUIPMENT AND MATERIALS SHALL BE FIELD VERIFIED PRIOR TO ORDERING, PROCURING AND FURNISHING SAME. L.NO EXTRA COMPENSATION OR CHARGES WILL BE ACCEPTED DUE TO DIFFERENCES BETWEEN THE ACTUAL MEASUREMENTS AND THOSE INDICATED ON THE PLAN. THOROUGHLY COORDINATE WORK WITH SITE CONDITIONS AND OTHER TRADES, DETERMINE EXACT ROUTE AND LOCATION OF EACH DUCT, PIPE, CONDUIT, ETC. BEFORE FABRICATION AND INSTALLATION. M.INSTALL WORK SUBSTANTIALLY AS INDICATED. VERIFY LOCATIONS AND ELEVATIONS ON JOB SITE; DO NOT DIRECTLY SCALE DRAWINGS. MAKE NECESSARY CHANGES IN ELEVATION, FITTINGS, OR OFFSETS TO ACCOMMODATE OBSTACLES OR INTERFERENCES. N.CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR DAMAGE TO THE BUILDING, PIPING OR EQUIPMENT THAT IS THE RESULT OF WORK FOR INSTALLATION OF THIS CONTRACT. O.THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR PATCH AND REPAIR OF ALL SURFACES TO MATCH EXISTING MATERIALS AND ADJACENT FINISHES ASSOCIATED WITH INSTALLATION/REMOVAL OF THIS WORK UNLESS SPECIFICALLY NOTED OTHERWISE. P.WORK SHALL BE COMPLETED TO MAINTAIN ALL NECESSARY AND REQUIRED CLEARANCES, ACCESSES, AND OPENINGS, SUCH THAT FULL FUNCTIONALITY, PROPER OPERATION, AND REPAIR AND MAINTENANCE ARE ENSURED. Q.WHERE DEVICE HEIGHT OF 48" OCCURS AT POINT OF CHANGE OF FINISH, THE DEVICE SHALL BE RAISED OR LOWERED TO OCCUR IN ONE FINISH. R.WHERE DEVICE OCCURS IN BRICK, TILE, OR BLOCK WALLS, THEY SHALL BE MOUNTED AT A VERTICAL MASONRY JOINT & IN EITHER THE TOP OR BOTTOM HORIZONTAL JOINT, CLOSEST TO THE MOUNTING HEIGHT. S.UNLESS OTHERWISE NOTED, ALL MOUNTING HEIGHT DIMENSIONS LISTED ARE TO THE CENTER LINE OF THE WALL BOX OR DEVICE. T.NOT ALL ABBREVIATIONS & SYMBOLS MAY APPLY TO THIS PROJECT. U.ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE LABELED AND LISTED BY A CERTIFIED TESTING LABORATORY OR AGENCY. V.DRAWINGS REPRESENT THE SCOPE OF WORK IN GENERAL ARRANGEMENT FORM AND ARE INTENDED TO SHOW GENERAL ROUTING AND REQUIRED SIZES/CAPACITIES OF SYSTEM COMPONENTS. GENERAL NOTES GENERAL DEMOLITION NOTES A.THE DEMOLITION PLANS AND NOTES HAVE BEEN PREPARED TO ASSIST THE CONTRACTORS IN IDENTIFYING THE AREAS AND ITEMS OF DEMOLITION AND RENOVATION ASSOCIATED WITH THIS PROJECT. THE INFORMATION PROVIDED IS NOT MEANT TO BE ALL-INCLUSIVE IN TERMS OF LISTING EACH AND EVERY SPECIFIC TASK TO BE PERFORMED. EACH CONTRACTOR WILL THOROUGHLY EXAMINE ALL CONTRACT DOCUMENTS PRIOR TO PERFORMING ANY WORK. B.DEMOLITION WORK INCLUDES, BUT IS NOT LIMITED TO, THE ITEMS INDICATED ON THE DEMOLITION DRAWINGS AND DESCRIBED IN THE DEMOLITION NOTES. THE EXTENT OF THE DEMOLITION WORK WILL INCLUDE ALL WORK REQUIRED TO COMPLETE THE PROJECT AND ENSURE WHETHER OR NOT THE WORK IS INDICATED ON THE DRAWINGS. C.EACH CONTRACTOR SHALL THOROUGHLY EXAMINE AND VERIFY ALL EXISTING CONDITIONS BEFORE PERFORMING ANY WORK AND IMMEDIATELY NOTIFY THE OWNER, IN WRITING, OF ANY DISCREPANCIES WITH THE DRAWINGS. D.ALL ITEMS NOTED TO BE REMOVED TO BE DISPOSED OF OFF-SITE BY RESPECTIVE CONTRACTORS, UNLESS NOTED OTHERWISE. WHERE INDICATED ON THE DRAWINGS AND/OR IN THE NOTES AS SALVAGE, THE CONTRACTOR SHALL CAREFULLY REMOVE INDICATED ITEMS AND STORE THEM WHERE DIRECTED BY THE OWNER. E.THE OWNER HAS THE OPTION TO RETAIN POSSESSION OF ANY REMOVED MATERIALS OR EQUIPMENT. ALL SUCH ITEMS SHALL BE CAREFULLY REMOVED AND STORED AT THE SITE BY THE CONTRACTOR WHERE DIRECTED BY THE OWNER. ANY MATERIALS OR EQUIPMENT NOT RETAINED BY THE OWNER WILL BECOME THE PROPERTY OF THE CONTRACTOR AND PROMPTLY REMOVED FROM SITE. F.ANY CONTRACTOR REMOVING OR MODIFYING MATERIAL CONTAINING ASBESTOS OR SUSPECTED OF CONTAINING ASBESTOS WILL NOTIFY THE OWNER AT ONCE AND STOP REMOVAL. IDENTIFICATION AND/OR REMOVAL OF ASBESTOS CONTAINING MATERIAL WILL BE THE RESPONSIBILITY OF THE OWNER. G.REFER TO ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR DEMOLITION WORK BY RESPECTIVE CONTRACTORS. EACH CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION ASSOCIATED WITH HIS CONTRACT AND SCOPE OF WORK. EACH CONTRACTOR IS RESPONSIBLE TO PATCH AND/OR REPAIR ANY AND ALL CONSTRUCTION AFFECTED BY HIS DEMOLITION. THE EXTENT OF PATCH AND REPAIR SHALL BE AS REQUIRED TO RECEIVE THE SCHEDULED NEW WORK. ALL CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK WITH OTHER CONTRACTORS BEFORE PERFORMING ANY WORK. H.ALL PATCH AND REPAIR WORK SHALL BE PERFORMED USING MATERIALS THAT MATCH THE EXISTING ADJACENT CONSTRUCTION. WHERE PATCHING EXISTING MASONRY WALLS OR INFILLING BETWEEN WALLS WITH MASONRY TO MATCH EXISTING, "TOOTH-IN" NEW MASONRY TO EXISTING. I.EACH CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING CONSTRUCTION SCHEDULED TO REMAIN. EACH CONTRACTOR IS RESPONSIBLE TO PATCH AND/OR REPAIR ANY AND ALL CONSTRUCTION AFFECTED BY THEIR DEMOLITION. EACH CONTRACTOR SHALL PATCH (SUBSTRATE AND FINISHED SURFACES) ANY EXISTING FINISHES AFFECTED BY THEIR RESPECTIVE WORK. J.EXISTING CONDITIONS INDICATED ARE OBTAINED FROM AVAILABLE SOURCES (EXISTING DRAWINGS, FIELD SURVEYS, ETC.) AND ARE NOT GUARANTEED TO BE TRUE AND EXACT. CONTRACTOR(S) SHALL FIELD VERIFY EXISTING CONDITIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE AFFECTED PORTION OF THE WORK. K.REMOVAL IN ITS ENTIRETY INCLUDES HANGERS, ELECTRICAL, CONTROLS, ETC., TO LEAVE A LIKE NEW OR MATCHING EXISTING CONDITION. A. INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF THE 2015 INTERNATIONAL PLUMBING CODE WITH NYS AMMENDMENTS AND APPLICABLE CORNELL UNIVERSITY DESIGN STANDARDS. B. PLUMBING CONTRACTOR SHALL PERFORM ALL TESTS, OBTAIN ALL PERMITS, INSPECTIONS AND CONNECTION FEES FOR PLUMBING INSTALLATION. C. PLUMBING CONTRACTOR SHALL PAY FOR ALL PERMITS, INSPECTIONS AND CONNECTION FEES FOR PLUMBING INSTALLATION. D. PLUMBING CONTRACTOR TO COORDINATE WITH ALL OTHER TRADES. E. ALL MATERIALS SHALL BE NEW, UNLESS OTHERWISE NOTED. F. PERFORM TESTING AS REQUIRED BY CODE AND LOCAL AUTHORITY HAVING JURISDICTION. G. PLUMBING CONTRACTOR SHALL VISIT THE SITE AND REVIEW EXISTING CONDITIONS AND MAKE ALLOWANCE FOR ANY EXISTING CONDITIONS PRIOR TO SUBMITTING BID. PLUMBING NOTES PLUMBING ABBREVIATIONS AD WHA P M PT P FD HB WH X P D CO S OR OR WH HB BALL VALVE PLUG VALVE SHUT-OFF VALVE IN RISER BALANCING VALVE MIXING VALVE CHECK VALVE ISOLATION VALVE SOLENOID VALVE STRAINER GLOBE VALVE PRESSURE REDUCING VALVE RELIEF VALVE X INDICATES P -PRESSURE T -TEMPERATURE PT -COMBINATION (PRESS./TEMP.) BRANCH CONNECTION -BOTTOM BRANCH CONNECTION -TOP ELBOW TURNED DOWN ELBOW TURNED UP CAP REDUCER CLEANOUT (FLOOR/WALL) WALL HYDRANT HOSE BIBB FLOOR DRAIN ROOF DRAIN UNION FLEXIBLE CONNECTOR DIRECTION OF FLOW DIRECTION OF DOWNWARD PITCH PRESSURE/TEMPERATURE TAP PRESSURE GAUGE THERMOMETER CIRCULATING PUMP METER WATER HAMMER ARRESTOR ACCESS DOOR DECK PLATE/YARD CLEAN-OUT POINT OF CONNECTION POINT OF DISCONNECTION EXTENT OF DEMOLITION PLUMBING SYMBOLS - VALVES & SPECIALTIES FEFEFE 1234567 A B C D E 515 SF LAB 580A 53 SF WOMEN 500TB 63 SF MECH 500UD STAIR 500SE CORRIDOR 500CA 342 SF LAB 573 712 SF LAB 575 127 SF OFFICE 582 278 SF OFFICE 582A 1 1 3 2 4 1 1 3 2 4 12311231 1 1 3 2 1 2 3 1 2 3 5 5 7 4" AW (E) 8 6 4" AW (E) 88 VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 12:11:57 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 CWC PLUMBING DEMOLITION AST MSM P-101 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 KEYED NOTES: 1. DISCONNECT AND REMOVE CUP SINK, TWO FAUCETS AND ASSOCIATED FAUCET VALVES AND ACCESSORIES. DISCONNECT AND REMOVE 1-1/2” DRAIN LINE BACK TO MAIN. FOR EACH FAUCET DISCONNECT AND REMOVE ONE 3/4” CW AND ONE 1/2" CW LINES BACK TO MAIN. CAP AND SEAL ALL PIPES. 2. DISCONNECT AND REMOVE NITROGEN TURRET AND ASSOCIATED ACCESSORIES. DISCONNECT AND REMOVE 1/2” N2 LINE BACK TO MAIN. CAP AND SEAL ALL PIPES. 3. DISCONNECT AND REMOVE NATURAL GAS TURRET AND ASSOCIATED ACCESSORIES. DISCONNECT AND REMOVE 1/2” NG LINE BACK TO MAIN. CAP AND SEAL ALL PIPES. 4. DISCONNECT AND REMOVE SINK, FAUCET, VALVES AND ACCESSORIES. DISCONNECT AND REMOVE 1/2” CW, 1/2” DHW, 1/2” DW, 2” DRAIN AND 1-1/2” VENT LINES BACK TO MAIN. CAP AND SEAL ALL PIPES. 5. DISCONNECT AND REMOVE EXISTING EMERGENCY SHOWER, PIPING, VALVES, ACCESSORIES AND SUPPLY PIPING. 6. DISCONNECT AND REMOVE PIPES STUBBED UP THROUGH THE ENCLOSURE IN THIS AREAS. CAP AND SEAL ALL PIPES. CAP BELOW ENCLOSURE. COORDINATE WITH ARCHITECTURAL PLANS FOR ENCLOSURE REPAIR. 7. DISCONNECT AND REMOVE CA LINE, ASSOCIATED VALVES AND ACCESSORIES. CAP AND SEAL AIR TIGHT BELOW ENCLOSURE. 8. DISCONNECT AND REMOVE AW DRAIN LINE, AND ACCESSORIES BACK TO 4" AW RISER. PREPARE RISER FOR CONNECTION TO NEW WORK. X 1/4" = 1'-0"1 PLUMBING - DEMO GENERAL NOTES: A. FIELD VERIFY EXACT LOCATION, DEPTH, COMPOSITION AND CONDITION OF ALL PIPING, VALVES AND SYSTEMS AS REQUIRED FOR WORK OF THE CONTRACT. B. DO NOT SHUT DOWN ANY PLUMBING LABORATORY GAS, NATURAL GAS, PROCESS PIPING OR RELATED SYSTEMS WITHOUT BUILDING OWNER’S PRIOR WRITTEN APPROVAL. FOLLOW ALL OWNER REQUIREMENTS AND SHUT DOWN PROCEDURES AS WELL AS ALL REQUIREMENTS FOR THIS PROJECT. C. DEMOLITION SHALL INCLUDE REMOVAL OF PIPING, HANGERS, RODS, INSULATION, SUPPORTS, FIXTURES, CARRIERS, TRIM, VALVES AND ACCESSORIES. DEMOLITION SHALL INCLUDE LEGAL DISPOSAL OF ALL ITEMS REMOVED. D. REMOVE AND REPLACE EXISTING CEILINGS AS REQUIRED FOR WORK SHOWN. REPLACE ALL DAMAGED CEILINGS; PROVIDE NEW CEILINGS. FIELD VERIFY CEILING TYPES AND EXTENT OF THIS WORK PRIOR TO BID DATE AND INCLUDE IT IN THE BID. E. PROVIDE ALL WORK IN COMPLIANCE WITH ALL LOCAL, STATE AND FEDERAL CODES. OBTAIN ALL REQUIRED PERMITS. F. PROVIDE CUTTING, CORING AND PATCHING OF ALL WALLS, SLABS AND DECKS AS REQUIRED FOR WORK SHOWN. COORDINATE ALL WORK WITH OWNER AND GENERAL CONTRACTOR. G. PITCH ALL SANITARY, WASTE PIPING SHOWN ON THESE DRAWINGS AS FOLLOWS: PIPING 3” AND SMALLER AT 2 PERCENT (1/4” PER FOOT) MINIMUM. PIPING 4” AND LARGER, PITCH AT 1 PERCENT (1/8” PER FOOT) MINIMUM) FEFEFE PLUMBING FIXTURE SCHEDULE FIXTURE PLAN CODE DESCRIPTION ACCESSORIES 1. FAUCET - HAMILTON LABORATORY SOLUTIONS - 33L44600 - 8" RIGID/SWING GOOSENECK SPOUT WITH ATMOSPHERIC VACUUM BREAKER - FULL FLOW LABORATORY SERRATED NOZZLE - VANDAL PROOF 4" WRISTBLADE HANDLE - ADA COMPLIANT - CHROME PLATED FINISH SK-A LABORATORY SINK - SPECIFIED WITH LABORATORY 2. DRAIN CASEWORK, EPOXY COATED - TOWN & COUNTRY #PP-27MT - CPVC 1-1/2" BOTTLE TYPE DEEP SEAL P-TRAP W/ UNSCREWABLE CLEANOUT JAR. - SPEARS 1-1/2" CPVC AIR ADMITTANCE VALVE # AAV-015C - SINK TAILPIECE TO MATCH 3. FIXTURE STOPS - McGUIRE #LF2167LKF - LEAD FREE. 1/2" SUPPLIES WITH 1/2" O.D. FLEXIABLE RISERS - LOOSE KEY STOPS 1. FAUCET 2. DRAIN SK-B LABORATORY CUP SINK - SPECIFIED WITH - TOWN & COUNTRY #PP-27MT LABORATORY CASEWORK, EPOXY COATED - CPVC 1-1/2" BOTTLE TYPE DEEP SEAL P-TRAP W/ UNSCREWABLE CLEANOUT JAR. - SPEARS 1-1/2" CPVC AIR ADMITTANCE VALVE # AAV-015C - SINK TAILPIECE TO MATCH 3. FIXTURE STOPS - McGUIRE #LF2167LKF - LEAD FREE. 1/2" SUPPLIES WITH 1/2" O.D. FLEXIABLE RISERS - LOOSE KEY STOPS 1. FAUCET 2. DRAIN SK-C LABORATORY FUME HOOD CUP SINK - SPECIFIED WITH - TOWN & COUNTRY #PP-27MT LABORATORY FUME HOOD, EPOXY COATED - CPVC 1-1/2" BOTTLE TYPE DEEP SEAL P-TRAP W/ UNSCREWABLE CLEANOUT JAR. - SPEARS 1-1/2" CPVC AIR ADMITTANCE VALVE # AAV-015C - SINK TAILPIECE TO MATCH 3. FIXTURE STOPS - McGUIRE #LF2167LKF - LEAD FREE. 1/2" SUPPLIES WITH 1/2" O.D. FLEXIABLE RISERS - LOOSE KEY STOPS 1. FAUCET - CHICHAGO FAUCET 969-317PLCTF - TIN LINED BRASS - ROUND SERRATED HOSE CONNECTION - 6" SWING GOOSENECK - WRIST BLADES 2. DRAIN SK-D LABORATORY SINK - SPECIFIED WITH LABORATORY - TOWN & COUNTRY #PP-27MT CASEWORK, EPOXY COATED - CPVC 1-1/2" BOTTLE TYPE DEEP SEAL P-TRAP W/ UNSCREWABLE CLEANOUT JAR. - SPEARS 1-1/2" CPVC AIR ADMITTANCE VALVE # AAV-015C - SINK TAILPIECE TO MATCH 3. FIXTURE STOPS - McGUIRE #LF2167LKF - LEAD FREE. 1/2" SUPPLIES WITH 1/2" O.D. FLEXIABLE RISERS - LOOSE KEY STOPS - 1/2" STAY OPEN VALVE EW-1 EMERGENCY EYEWASH - BRADLEY S19-270E - BRADLEY S19-2000* EMERGENCY FIXTURE THERMOSTATIC MIXING VALVE - ASSE1071 - HORIZONTAL SUPPLY ES-1 EMERGENCY SHOWER - BRADLEY S19-120FMBF - PLASTIC SHOWER HEAD W/SS SHROUD - ANSI Z358.1 - ANSI Z358.1 MV-1 EMERGENCY SHOWER MIXING VALVE - BRADLEY EFX-20 - LIQUID FILLED THERMOMETER - FACTORY SET TO 85°F 1234567 A B C D E 515 SF LAB 580A 218 SF WRITE-UP 580 53 SF WOMEN 500TB 63 SF MECH 500UD STAIR 500SE CORRIDOR 500CA 342 SF LAB 573 712 SF LAB 575 127 SF OFFICE 582 278 SF OFFICE 582A 3 P P 1 2 2 15 CA CA VACVAC N2 N2 N2 CA NG CW CW CW HW/CW CA VAC N2 N2 CA NG CW CW CW NIT (E) CW (E) NG (E) LOCATED IN SOFFIT CA CA VAC VAC N2 N2 N2 CA NGCW CW 1 1 NG (E) CW (E) NIT (E) LOCATED IN SOFFIT 3/4" NG (E) 3/4" CW (E) 1/2" N2 (E) 3" AW BELOW FLOOR 3 P CW, N2, NG AND A SURFACE MOUNTED AND THROUGH CASEWORK AT THIS LOCATION 1 5 1 1 1 1 1 1-1/2" AW BELOW FLOOR LAB STACK #2 4" AW UP AND DOWN (E) 4" AW UP AND DOWN (E) 7 8 7 8 8 7 8 7 9 9 9 9 10 11 12 110 11 12 110 11 12 1413 1413 10 11 12 14 13 7 7 7 7 18 18 16 3 4 P 3" AW UP AND DOWN (E) 3" AW UP AND DOWN (E) 4" AW UP AND DOWN (E) EXISTING DRAIN LINE TO REMAIN NIT HW CW NG A RACKED AGAINST WALL IN CHASE DW NIT (N2) HW CW NG RACKED AGAINST WALL IN CHASE EMERGENCY SAFETY SHOWER EMERGENCY SAFETY SHOWER P P 1/2" CA AND 1/2" NIT(N2) LOCATED AGAINST WALL AND DOWN THROUGH ENCLOSURE IN THIS LOCATION CO CO CO A P-102 B P-102 PP 15 1/2" CW 1/2" N2 1/2" NG 1/2" A 15 15 NIT(N2) DW HW CW NG 15 SK-B SK-BSK-C SK-B SK-C 1 7 10 11 12 SK-B SK-B SK-B SK-B EW-1 EW-1 SK-CSK-C SK-A EW-1 ES-1 ES-1 EW-1 MV-1 1/2" TW 1/2" CA 1/2" NIT 3/4" HW 3/4" CW 1/2" HW 1/2" CW TIE NEW CA INTO EXISTING LINE 1/2" CW TO PRESS 2" AW FROM PRESS PROVIDE TRAP AND HUB DRAIN SK-A SK-A SK-D SK-A 13 14 16 16 17 13 14 18 NG EMERGENCY SHUT-OFF VALVE NG EMERGENCY SHUT-OFF VALVE 18 P PIPING STACKED THROUGH THE BACK OF CABINET ENCLOSURE 1/2" DW 1/2" NIT 3/4" HW 3/4" CW 3/4" NG 1/2" CA PIPING STACKED THROUGH THE BACK OF CABINET ENCLOSURE 1/2" NIT 3/4" CW 3/4" NG 1/2" CA VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 12:12:00 PMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 CWC PLUMBING NEW WORK AST MSM P-102 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020NORTH1/4" = 1'-0"1 PLUMBING - NEW WORK KEYED NOTES: 1. PROVIDE 1-1/2" AW DRAIN WITH AIR ADMITTANCE VALVE UP TO PROPOSED SINK. 2. PROVIDE CORE DRILL IN EXISTING CONCRETE FLOOR. COORDINATE LOCATION OF CORE PENETRATION WITH ARCHITECTURAL PLANS AND EXISTING STRUCTURAL ELEMENTS. 3. CONNECT 3" AW TO EXISTING 4" AW RISER. 4. CONNECT 1-1/2" AW TO EXISTING 4" AW RISER. 5. CONNECT 2" AW TO EXISTING 3" AW RISER. 6. CONNECT 3" AW TO EXISTING 3" AW RISER. 7. PROVIDE 3/4" CW LINE TO SINK FAUCET. 8. PROVIDE 1/2" CW AND 1/2" DHW CONNECTIONS TO SINK. 9. PROVIDE THERMOSTATIC MIXING VALVE BELOW COUNTERTOP FOR EMERGENCY EYE WASH STATION AT SINK. PROVIDE 1/2" AND 1/2" DHW TO TEMPERING VALVE. PROVIDE 1/2" TEMPERED WATER TO EMERGENCY EYE WASH 10. PROVIDE 1/2” CA AND MAKE CONNECTION TO CA TURRET IN LABORATORY FUME HOOD. TURRETS PROVIDED BY LABORATORY FUME HOOD MANUFACTURER. FIELD COORDINATE FINAL CA CONNECTIONS TO FUME HOOD. X 1/4" = 1'-0"A LAB 580 ELEVATION VIEW 1/4" = 1'-0" B LAB 573 ELEVATION VIEW 11. PROVIDE 3/4” VAC AND MAKE CONNECTION TO VAC TURRET IN LABORATORY FUME HOOD. TURRETS PROVIDED BY LABORATORY FUME HOOD MANUFACTURER. FIELD COORDINATE FINAL VAC CONNECTIONS TO FUME HOOD. 12. PROVIDE 1/2” N2 AND MAKE CONNECTION TO NIT TURRET IN LABORATORY FUME HOOD. TURRETS PROVIDED BY LABORATORY FUME HOOD MANUFACTURER. FIELD COORDINATE FINAL N2 CONNECTIONS TO FUME HOOD. 13. PROVIDE 1/2” CA AND MAKE CONNECTION TO CA TURRET ON LABORATORY BENCH TOP TURRETS PROVIDED BY LABORATORY CASEWORK MANUFACTURER. FIELD COORDINATE FINAL CA CONNECTION LOCATION. 14. PROVIDE 1/2” N2 AND MAKE CONNECTION TO N2 TURRET ON LABORATORY BENCH TOP. TURRETS PROVIDED BY LABORATORY CASEWORK MANUFACTURER. FIELD COORDINATE FINAL N2 CONNECTION LOCATION. 15. PROVIDE 1/2" DW LINE TO SINK. 16. PROVIDE 1/2" CW LINE TO PRESSES. PROVIDE RPZ BACKFLOW DEVICE. ROUTE RELIEF DRAIN TO HUB. 17. PROVIDE 2" DRAIN TEMPERING FITTING AND VALVE. CONNECT CW TO VALVE. THERM-OMEGA-TECH OR EQUAL. 18. ALTERNATE: THE NATURAL GAS (NG) SCOPE OF WORK SHALL BE PRICED AS AN ALTERNATE. THIS SHALL INCLUDE CONNECTION POINTS TO EXISTING SERVICES, 1/2" NG DISTRIBUTION PIPING, CONNECTIONS TO NG TURRETS ON LABORATORY BENCHTOP (TURRETS PROVIDED BY LABORATORY CASEWORK MANUFACTURER), AND EMERGENCY GAS SHUT-OFF ASSEMBLIES. FIELD COORDINATE FINAL NG CONNECTION LOCATION. AMPERE ABANDON ALTERNATING CURRENT ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPERES INTERRUPTING CURRENT AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAUGE BELOW FINISHED FLOOR BELOW FINISHED GRADE BASIC IMPULSE LEVEL BUILDING CONDUIT CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION CIRCUIT CEILING CONCRETE CONNECTION CONTROL PANEL CURRENT TRANSFORMER COPPER DIRECT CURRENT DETAIL DIAMETER DISCONNECT DOWN DRAWING ELECTRIC, ELECTRICAL ELECTRICAL CONTRACTOR ELEVATION EMERGENCY EQUIPMENT EXISTING TO REMAIN EXISTING EXHAUST EXTERNAL FIRE ALARM FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM CONTROL PANEL FURNISHED BY OTHERS FAN COIL UNIT FULL LOAD AMPERES FLEXIBLE FLOOR FINISHED FEET FUSE GAUGE GALVANIZED GENERAL CONTRACTOR GENERATOR GROUND FAULT INTERRUPTER GRADE GROUND HORSEPOWER HERTZ INTERRUPTING JUNCTION BOX KILO AMPERE THOUSAND CIRCULAR MILS KILOVOLT KILOVOLT AMPERES KILOVOLT AMPERES REACTIVE KILOWATT KILOWATT HOUR ABBREVIATIONS LA L-N LED MAX MCB MCC MDP MH MIN MLO MOV MOD MVA NC NE NEC NEMA NIC NO NTS OC OL OH P PC PF PFFB PH, Ø PNL PT PVC REQ'D RGS RLA RES RMC RMS RPM RX SA SEC SMR SYM T TEMP TC TRANS TYP UG UH UNO V VAC VM VP W WG W/ W/O WP WT XFMR A, AMP ABN AC AFF AFG AIC ATS AWG BFF BFG BIL BLDG C CB CCTV CKT CLG CONC CONN CP CT CU DC DET DIA, Ø DISC DN DWG E, (E) EC ELEV EM, EMER EQUIP ETR EX, EXIST EXH EXT FA FAAP FACP FBO FCU FLA FLEX FLR FIN FT FU GA GALV GC GEN GFI GR GRD HP HZ INT JB KA KCMIL KV KVA KVAR KW KWH LIGHTNING ARRESTOR LINE TO NEUTRAL LIGHT EMITTING DIODE MAXIMUM MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION PANEL MANHOLE MINIMUM MAIN LUG ONLY METAL OXIDE VARISTOR MOTOR OPERATED DAMPER MEGAVOLT AMPERES NORMALLY CLOSED NORMAL EMERGENCY NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION NOT IN CONTRACT NORMALLY OPEN NOT TO SCALE ON CENTER OVERLOAD OVERHEAD POLE PHOTOCELL POWER FACTOR PROVISIONS FOR FUTURE BREAKER PHASE PANEL POTENTIAL TRANSFORMER POLYVINYLCHLORIDE REQUIRED RIGID GALVANIZED STEEL RUNNING LOAD AMPS RESISTOR RIGID METAL CONDUIT ROOT MEAN SQUARE REVOLUTIONS PER MINUTE REMOVE EXISTING SURGE ARRESTOR SECONDARY SURFACE METAL RACEWAY SYMMETRICAL TRANSFORMER TEMPERATURE TRIP COIL TRANSFORMER TYPICAL UNDERGROUND UNIT HEATER UNLESS NOTED OTHERWISE VOLTS VOLTS ALTERNATING CURRENT VOLT METER VAPOR PROOF WATTS WIRE GUARD WITH WITHOUT WEATHERPROOF WEIGHT TRANSFORMER DRAWING NOTE -REFER TO DRAWING NOTE LIST ON SHEET (NEW WORK) DRAWING CONVENTIONS DRAWING NOTE -REFER TO DRAWING NOTE LIST ON SHEET (DEMOLITION)# # FEEDER TAG -REFER TO FEEDER SCHEDULE ON DRAWING Ex.xxX 1. CONTRACTORS ARE URGED TO INSPECT THE SITE BEFORE SUBMITTING A BID PROPOSAL TO ENSURE KNOWLEDGE OF PROJECT REQUIREMENTS AND SITE CONDITIONS. IF NO CLARIFICATION IS REQUESTED, IT WILL BE CONSIDERED THAT THE CONTRACTORS ARE IN FULL UNDERSTANDING OF PROJECT REQUIREMENTS. 2. PROVIDE LABOR, SUPERVISION, EQUIPMENT, MATERIALS, CONSTRUCTION TOOLS, TRANSPORTATION, INSURANCE, AND SERVICES REQUIRED FOR THE COMPLETE INSTALLATION OF THIS WORK IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE, AND LOCAL CODES, AUTHORITIES HAVING JURISDICTION, AND STANDARDS INCLUDING BUT NOT LIMITED TO, ASHRAE, IBC, NEC, AND NFPA. 3. NOTHING CONTAINED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS SHALL BE CONSTRUED TO BE IN CONFLICT WITH ANY STATE OR LOCAL CODES, ORDINANCES OR REGULATIONS. 4. THE USE OF THE WORD "PROVIDE" SHALL MEAN TO FURNISH, INSTALL AND CONNECT, READY TO USE. 5. THE USE OF THE WORD "FURNISH" SHALL MEAN TO PROCURE AND DELIVER TO THE SITE. 6. THE USE OF THE WORD "INSTALL" SHALL MEAN TO PHYSICALLY PLACE INTO SERVICE AND CONNECT, READY TO USE. 7. EQUIPMENT AND MATERIALS SHALL BE INSTALLED BY SKILLED TRADESMEN, FAMILIAR WITH THE COMPONENTS TO BE INSTALLED, AND IN ACCORDANCE WITH BEST PRACTICES OF THE INDUSTRY. 8. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS, AND ACCESSORIES THAT MAY BE REQUIRED. THIS CONTRACTOR SHALL CAREFULLY EXAMINE THE ARCHITECTURAL; STRUCTURAL; HEATING, VENTILATING AND AIR- CONDITIONING; ELECTRICAL; PLUMBING; AND OTHER PROJECT DOCUMENTS AS MAY BE NECESSARY FOR PROPER ORIENTATION OR INSTALLATION AND SHALL PROVIDE OFFSETS, FITTINGS, AND ACCESSORIES TO MEET PROJECT CONDITIONS. 9. DISCREPANCIES BETWEEN DRAWINGS OR BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE REPORTED TO PROFESSIONAL IN WRITING. OBTAIN WRITTEN INSTRUCTIONS FROM PROFESSIONAL AS TO THE MANNER IN WHICH TO PROCEED. NO DEPARTURES FROM THE PROJECT DOCUMENTS SHALL BE MADE WITHOUT PRIOR WRITTEN ACCEPTANCE OF THE PROFESSIONAL. 10. DIMENSIONS, CLEARANCES, AND LOCATIONS OF EQUIPMENT AND MATERIALS SHALL BE FIELD VERIFIED PRIOR TO ORDERING, PROCURING AND FURNISHING SAME. 11. NO EXTRA COMPENSATION OR CHARGES WILL BE ACCEPTED DUE TO DIFFERENCES BETWEEN THE ACTUAL MEASUREMENTS AND THOSE INDICATED ON THE PLAN. THOROUGHLY COORDINATE WORK WITH SITE CONDITIONS AND OTHER TRADES, DETERMINE EXACT ROUTE AND LOCATION OF EACH DUCT, PIPE, CONDUIT, ETC. BEFORE FABRICATION AND INSTALLATION. 12. INSTALL WORK SUBSTANTIALLY AS INDICATED. VERIFY LOCATIONS AND ELEVATIONS ON JOB SITE; DO NOT DIRECTLY SCALE DRAWINGS. MAKE NECESSARY CHANGES IN ELEVATION, FITTINGS, OR OFFSETS TO ACCOMMODATE OBSTACLES OR INTERFERENCES. 13. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR DAMAGE TO THE BUILDING, PIPING OR EQUIPMENT THAT IS THE RESULT OF WORK FOR INSTALLATION OF THIS CONTRACT. 14. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR PATCH AND REPAIR OF ALL SURFACES TO MATCH EXISTING MATERIALS AND ADJACENT FINISHES ASSOCIATED WITH INSTALLATION/REMOVAL OF THIS WORK. 15. WORK SHALL BE COMPLETED TO MAINTAIN ALL NECESSARY AND REQUIRED CLEARANCES, ACCESSES, AND OPENINGS, SUCH THAT FULL FUNCTIONALITY, PROPER OPERATION, AND REPAIR AND MAINTENANCE ARE ENSURED. 16. WHERE DEVICE HEIGHT OCCURS AT POINT OF CHANGE OF FINISH, THE DEVICE SHALL BE RAISED OR LOWERED TO OCCUR IN ONE FINISH. ENSURE RESULTING HEIGHT DOES NOT EXCEED ADA REQUIREMENTS. 17. WHERE DEVICE OCCURS IN BRICK, TILE, OR BLOCK WALLS, THEY SHALL BE MOUNTED AT A VERTICAL MASONRY JOINT AND IN EITHER THE TOP OR BOTTOM HORIZONTAL JOINT, CLOSEST TO THE MOUNTING HEIGHT. ENSURE RESULTING HEIGHT DOES NOT EXCEED ADA REQUIREMENTS. 18. UNLESS OTHERWISE NOTED, ALL MOUNTING HEIGHT DIMENSIONS LISTED ARE TO THE CENTER LINE OF THE WALL BOX OR DEVICE. 19. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE LABELED AND LISTED BY A CERTIFIED TESTING LABORATORY OR AGENCY. 20. DRAWINGS REPRESENT THE SCOPE OF WORK IN GENERAL ARRANGEMENT FORM AND ARE INTENDED TO SHOW GENERAL ROUTING AND REQUIRED SIZES/CAPACITIES OF SYSTEM COMPONENTS. EXACT ROUTING OF CONDUITS AND CABLES SHALL BE DETERMINED BY JOB SITE SURVEY. 21. PROVIDE 2-#12, 1-#12 GND IN MINIMUM 3/4"C FOR ALL 20A, SINGLE POLE BRANCH CIRCUITS, UNLESS OTHERWISE NOTED. FOR 120V BRANCH CIRCUITS, PROVIDE NEXT LARGER WIRE SIZE FOR ONE-WAY CIRCUIT DISTANCES GREATER THAN 100 FEET. FOR 208V BRANCH CIRCUITS, PROVIDE NEXT LARGER WIRE SIZE FOR ONE-WAY CIRCUIT DISTANCES GREATER THAN 150 FEET. GENERAL NOTES: 1. THE DEMOLITION PLANS AND NOTES HAVE BEEN PREPARED TO ASSIST THE CONTRACTORS IN IDENTIFYING THE AREAS AND ITEMS OF DEMOLITION AND RENOVATION ASSOCIATED WITH THIS PROJECT. THE INFORMATION PROVIDED IS NOT MEANT TO BE ALL-INCLUSIVE IN TERMS OF LISTING EACH AND EVERY SPECIFIC TASK TO BE PERFORMED. EACH CONTRACTOR WILL THOROUGHLY EXAMINE ALL CONTRACT DOCUMENTS PRIOR TO PERFORMING ANY WORK. 2. DEMOLITION WORK INCLUDES, BUT IS NOT LIMITED TO, THE ITEMS INDICATED ON THE DEMOLITION DRAWINGS AND DESCRIBED IN THE DEMOLITION NOTES. THE EXTENT OF THE DEMOLITION WORK WILL INCLUDE ALL WORK REQUIRED TO COMPLETE THE PROJECT AND ENSURE WHETHER OR NOT THE WORK IS INDICATED ON THE DRAWINGS. 3. EACH CONTRACTOR SHALL THOROUGHLY EXAMINE AND VERIFY ALL EXISTING CONDITIONS BEFORE PERFORMING ANY WORK AND IMMEDIATELY NOTIFY THE ARCHITECT, IN WRITING, OF ANY DISCREPANCIES WITH THE DRAWINGS. 4. ANY WORK PERFORMED AS PART OF THIS CONTRACT REQUIRING OR ALTERATION WILL BE THE RESPONSIBILITY OF THE RESPECTIVE CONTRACTOR. 5. ALL ITEMS NOTED TO BE REMOVED TO BE DISPOSED OF OFF-SITE BY RESPECTIVE CONTRACTORS, UNLESS NOTED OTHERWISE. WHERE INDICATED ON THE DRAWINGS AND/OR IN THE NOTES AS 'SALVAGE AND DELIVER TO OWNER', THE CONTRACTOR WILL CAREFULLY REMOVE INDICATED ITEMS AND STORE THEM WHERE DIRECTED BY THE OWNER. 6. THE OWNER HAS THE OPTION TO RETAIN POSSESSION OF ANY REMOVED MATERIALS OR EQUIPMENT. ALL SUCH ITEMS SHALL BE CAREFULLY REMOVED AND STORED AT THE SITE BY THE CONTRACTOR WHERE DIRECTED BY THE OWNER. ANY MATERIALS OR EQUIPMENT NOT RETAINED BY THE OWNER WILL BECOME THE PROPERTY OF THE CONTRACTOR AND PROMPTLY REMOVED FROM SITE. 7. ANY CONTRACTOR REMOVING OR MODIFYING MATERIAL CONTAINING ASBESTOS OR SUSPECTED OF CONTAINING ASBESTOS WILL NOTIFY THE OWNER AT ONCE AND STOP REMOVAL. IDENTIFICATION AND/OR REMOVAL OF ASBESTOS CONTAINING MATERIAL WILL BE THE RESPONSIBILITY OF THE OWNER. 8. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, TECHNOLOGY AND PLUMBING DRAWINGS FOR DEMOLITION WORK BY RESPECTIVE CONTRACTORS. EACH CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION ASSOCIATED WITH HIS CONTRACT AND SCOPE OF WORK. EACH CONTRACTOR IS RESPONSIBLE TO PATCH AND/OR REPAIR ANY AND ALL CONSTRUCTION AFFECTED BY HIS DEMOLITION. THE EXTENT OF PATCH AND REPAIR SHALL BE AS REQUIRED TO RECEIVE THE SCHEDULED NEW WORK. ALL CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK WITH OTHER CONTRACTORS BEFORE PERFORMING ANY WORK. 9. ALL PATCH AND REPAIR WORK SHALL BE PERFORMED USING MATERIALS THAT MATCH THE EXISTING ADJACENT CONSTRUCTION. WHERE PATCHING EXISTING MASONRY WALLS OR INFILLING BETWEEN WALLS WITH MASONRY TO MATCH EXISTING, "TOOTH-IN" NEW MASONRY TO EXISTING. 10. EACH CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING CONSTRUCTION SCHEDULED TO REMAIN. EACH CONTRACTOR IS RESPONSIBLE TO PATCH AND/OR REPAIR ANY AND ALL CONSTRUCTION AFFECTED BY THEIR DEMOLITION. EACH CONTRACTOR SHALL PATCH (SUBSTRATE AND FINISHED SURFACES) ANY EXISTING FINISHES AFFECTED BY THEIR RESPECTIVE WORK. 11. EXISTING CONDITIONS INDICATED ARE OBTAINED FROM AVAILABLE SOURCES (EXISTING DRAWINGS, FIELD SURVEYS, ETC.) AND ARE NOT GUARANTEED TO BE TRUE AND EXACT. CONTRACTOR(S) SHALL FIELD VERIFY EXISTING CONDITIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE AFFECTED PORTION OF THE WORK. 12. REMOVAL IN ITS ENTIRETY INCLUDES HANGERS, ELECTRICAL, CONTROLS, ETC., TO LEAVE A LIKE NEW OR MATCHING EXISTING CONDITION. GENERAL DEMOLITION NOTES: EXISTING DEVICES TO REMAIN ARE SHOWN IN LIGHT LINEWEIGHT. EXISTING DEVICES TO BE REMOVED ARE SHOWN IN DASHED LINEWEIGHT. NOT ALL ABBREVIATIONS & SYMBOLS MAY APPLY TO THIS PROJECT. GENERAL SYMBOL NOTES: 1. 2. 3. FLOOR BOX -SUBSCRIPT INDICATES TYPE -(SEE SPECIFICATIONS) RECEPTACLES FLOOR POKE-THRU P WHIP BOX -SUBSCRIPT INDICATES TYPE -(SEE SPECIFICATIONS) DUPLEX RECEPTACLE -NEMA 5-20R -WALL MOUNTED -FLUSH SYMBOL DESIGNATIONS: OC -MOUNT 6" ABOVE SINK OR COUNTERTOP F -FLOOR MOUNTED GFI -GROUND FAULT INTERRUPTER H -MOUNT HORIZONTALLY 6" ABOVE SINK OR COUNTERTOP IG -ISOLATED GROUND Q -QUAD SP -SURGE PROTECTED TP -TAMPER PROOF USB -USB CHARGER C -CEILING MOUNTED WP -GROUND FAULT INTERRUPTER WITH WEATHERPROOF WHILE-IN-USE COVER # -CIRCUIT NUMBER DOUBLE DUPLEX RECEPTACLE -NEMA 5-20R -WALL MOUNTED -FLUSH SPECIAL PURPOSE RECEPTACLE -SUBSCRIPT INDICATES NEMA TYPE WB FB DOUBLE DUPLEX RECEPTACLE -NEMA 5-20R -CEILING MOUNTED DUPLEX RECEPTACLE -NEMA 5-20R -CEILING MOUNTED SIMPLEX RECEPTACLE -NEMA 5-20R -WALL MOUNTED -FLUSH X X X NOTE: WALL MOUNTED DEVICES SHALL BE 18" AFF TO CENTER OF BOX, UNO MANUAL PULL STATION -42" AFF TO CENTER OF HANDLE FIRE ALARM AUDIBLE NOTIFICATION DEVICE -MOUNTING HEIGHT PER NFPA 72 HEAT DETECTOR, COMBINATION UOI, NUMBER INDICATES TEMPERATURE RATING SMOKE DETECTOR, PHOTOELECTRIC TYPE (D -DUCT MOUNTED, I -IONIZATION TYPE, A -UNIT WITH AUXILIARY CONTACT) AUDIBLE/VISIBLE NOTIFICATION DEVICE -MOUNTING HEIGHT PER NFPA 72, NUMBER INDICATES CANDELA RATING VISIBLE NOTIFICATION DEVICE -MOUNTING HEIGHT PER NFPA 72, NUMBER INDICATES CANDELA RATING P Ƨ ADDRESSABLE CONTROL MODULEACM AM ADDRESSABLE INTERFACE MODULE TS TAMPER SWITCH CONNECTION FS FLOW SWITCH CONNECTION RTS REMOTE TEST STATION ELECTRIC GONG -CONNECT TO 120VAC CIRCUIT AND FIRE ALARM SYSTEM DP DIFFERENTIAL PRESSURE SWITCH FACP FAAP FIRE ALARM CONTROL PANEL -6' AFF TO TOP OF BOX FIRE ALARM ANNUNCIATOR PANEL -6' AFF TO TOP OF BOX K CITY KEY BOX DH MAGNETIC DOOR HOLDER 15 15 TECHNOLOGY DATA OUTLET -WALL MOUNTED -FLUSH DEVICE DESIGNATIONS: OC -MOUNT 6" ABOVE COUNTER TOP F -FLOOR MOUNTED H -MOUNT HORIZONTALLY 6" ABOVE COUNTER TOP W -WALL MOUNTED, 48" AFF TO CENTER # -NUMBER OF CAT 6 JACKS C -CEILING MOUNTED VOICE OUTLET -WALL MOUNTED -FLUSH DATA OUTLET, CEILING MOUNTED NOTE: WALL MOUNTED DEVICES SHALL BE 18" AFF TO CENTER OF BOX, UNO S CEILING MOUNTED SPEAKER S WALL MOUNTED SPEAKER TV CATV / TV MONITOR OUTLET -WALL MOUNTED -FLUSH C WALL MOUNTED CLOCK VC VOLUME CONTROL TC ELECTRONIC TIME CLOCK WIRELESS ACCESS POINT DATA OUTLET -TWO (2) CAT 6A JACKS # # WAP EQUIPMENT DISCONNECT SWITCH, VOLTAGE RATING TO MATCH CIRCUIT, NUMBER INDICATES AMPERE RATING FUSED DISCONNECT SWITCH, VOLTAGE RATING TO MATCH CIRCUIT, NUMBERS INDICATE DISCONNECT/FUSE AMPERE RATING MAGNETIC MOTOR STARTER, NUMBER INDICATES NEMA SIZE COMBINATION DISCONNECT MAGNETIC MOTOR STARTER, NUMBERS INDICATE DISCONNECT AMPERE/NEMA SIZE RATING MANUAL MOTOR STARTER EQUIPMENT CONNECTION M M METER R ENCLOSED RELAY ST SHUNT TRIP VFD VARIABLE FREQUENCY DRIVE 30 30/15 00 30/1 J J JUNCTION BOX -WALL OR CEILING B BLANK OUTLET JUNCTION BOX -RECESSED IN FLOOR PB PULL BOX 2 2-POLE TOGGLE SWITCH SPD SURGE PROTECTIVE DEVICE CB ENCLOSED CIRCUIT BREAKER, NUMBER INDICATES AMPERE RATING 30 CONTACTORC CR CORD REEL PS POWER SUPPLY PUSH BUTTON MUSHROOM SWITCH E EMERGENCY POWER OFF BUTTON -(EPO) DAYLIGHT SENSOR SWITCHES PASSIVE INFRARED VACANCY SENSOR -CEILING MOUNTED SWITCH PACK SINGLE POLE WALL SWITCH, LOWER CASE LETTER INDICATES SWITCHING ARRANGEMENT SWITCH DESIGNATIONS: 3 -THREE WAY 4 -FOUR WAY D -DIMMER SWITCH WITH MOMENTARY ON/OFF PUSHBUTTON K -KEYED L -LOW VOLTAGE M -MOMENTARY CONTACT MT -MANUAL TIMER U -ULTRASONIC TYPE B -SENSOR SHALL BE PROVIDED WITH ISOLATED AUXILIARY CONTACT FOR BMS INPUT P -PILOT LIGHT T -DIGITAL TIMER DS SP CS V PC PHOTOCELL DH DAYLIGHT HARVESTING CONTROLLER ER RC CS NOTE: WALL MOUNTED SWITCHES SHALL BE 46" AFF TO CENTER OF DEVICE. O PASSIVE INFRARED OCCUPANCY SENSOR -CEILING MOUNTED PASSIVE INFRARED VACANCY SENSOR -WALL MOUNTED EMERGENCY LIGHTING CONTROL UNIT DIGITAL ROOM CONTROLLER RELAY (X = QUANTITY OF RELAYS) X CS V DISTRIBUTION T DISTRIBUTION TRANSFORMER, REFER TO ONE LINE DIAGRAM 480V FLUSH MOUNTED PANELBOARD 480V SURFACE MOUNTED PANELBOARD 208V FLUSH MOUNTED PANELBOARD 208V SURFACE MOUNTED PANELBOARD SURFACE MOUNTED CONTROL PANEL FLUSH MOUNTED CONTROL PANEL HOMERUN TO PANELBOARD -SHORT LINE(S) = HOT CONDUCTOR(S); LONG LINE = NEUTRAL CONDUCTOR; LINE WITH DOT = GROUND EQUIPMENT ON SAME CIRCUIT, BUT SEPARATELY CONTROLLED HVAC CONTROL POWER VAV TRANSFORMER, 120VAC PRIMARY, 24VAC SECONDARY, CLASS II, 300VA. MOUNT TO JUNCTION BOX ABOVE CEILING. PROVIDE PRIMARY FUSE AND SINGLE-POLE SINGLE-THROW PRIMARY SNAP SWITCH. T 24VAC WIRING These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 10:51:52 AMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 RAM ELECTRICAL SYMBOLS, NOTES & ABBREVIATIONS AST DSU E-000 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER CAT. NUMBER LAMP TYPE COLOR LUMENS VOLTAGE WATTS CRI DIMMING MOUNTING DESCRIPTION LA LEDALITE 7406LBCQG087DEW-A1-48 LED 3500K 9200 UNV 80 ≥80 0-10V (1-100%)SUSPENDED (AIRCRAFT CABLE) 8'-0" LINEAR DIRECT/INDIRECT LIGHT FIXTURE WITH 80% DOWNLIGHT, 20% UPLIGHT. FIXTURE SHALL BE MOUNTED 4'-0" BELOW CEILING. LB LEDALITE 7406LBCQG047DEW-A1-48 LED 3500K 4600 UNV 40 ≥80 0-10V (1-100%)SUSPENDED (AIRCRAFT CABLE) 4'-0" LINEAR DIRECT/INDIRECT LIGHT FIXTURE WITH 80% DOWNLIGHT, 20% UPLIGHT. FIXTURE SHALL BE MOUNTED 4'-0" BELOW CEILING. LC METALUX 24EN-LD2-45-UNV-L835-HCD1 LED 3500K 4500 UNV 38 ≥80 0-10V (1-100%)RECESSED 2'X4' ARCHITECTURAL RECESSED TROFFER WITH CENTER LED CHANNEL LD HALO SLD612835WH LED 3500K 1200 UNV 15 ≥80 NON-DIMMING SURFACE 6-INCH, ULTRA-LOW PROFILE (0.7" DEPTH BELOW CLG.), SURFACE LED DOWNLIGHT LE HALO HC820D010-HM81520835-81WDC LED 3500K 2000 UNV 21 ≥80 0-10V (1-100%)RECESSED 8-INCH RECESSED LED DOWNLIGHT LF LEDALITE 7406LBEQG087DEW-A2-24 LED 3500K 3400 UNV 28 ≥80 0-10V (1-100%)SUSPENDED (AIRCRAFT CABLE) 8'-0" LINEAR DIRECT/INDIRECT LIGHT FIXTURE WITH 80% DOWNLIGHT, 20% UPLIGHT. FIXTURE SHALL BE MOUNTED 1'-0" BELOW CEILING. PANELBOARD P-5G LOCATION: LAB 573 MAIN BUS AMPS: 100A SERVICE VOLTAGE: 208Y/120V, 3PH, 4W MAIN CIRCUIT BREAKER: NONE MOUNTING: RECESSED FEEDER SIZE: (4) #1/0, (1) #6 GND IN 2"C FEED: MAIN SWITCHBOARD FEED THRU LUGS: YES S.C. RATING: 10,000 AMPS RMS SYM. DESCRIPTION PHASE AMPS TRIP POLES TRIP PHASE AMPS DESCRIPTIONPH A PH B PH C AMPS AMPS PH A PH B PH C LAB 573 CARVER PRESS WM RECEP. 16.0 20A/1P 1 2 20A/1P 6.0 LAB 573 FUME HOOD LAB 573 TENSILE TESTER WM RECEP. 2.5 20A/1P 3 4 20A/1P 6.0 LAB 573 FUME HOOD LAB 573 BENCH WIREMOLD 6.0 20A/1P 5 6 20A/1P 5.0 LAB 573 REFRIG. WM RECP. LAB 573 BENCH WIREMOLD 6.0 20A/1P 7 8 20A/1P 14.0 LAB 573 GLASSWARE OVEN WM RECEP. LAB 573 VAV TRANSFORMER 1.0 20A/1P 9 10 20A/1P 4.5 LAB 573 EAST WALL WIREMOLD MECH. RM. FIRE ALARM NAC PANEL 3.0 20A/1P 11 12 20A/1P 0.1 CORRIDOR DOOR HOLDERS *BOOSTER PUMP MECH RM.20A/1P 13 14 20A/1P 4.0 LAB 573 HOOD VACUUM PUMP *VARIAC #1 571 20A/1P 15 16 20A/1P *SINGLE RECEP. 571 LAB 573 ROTO-VAP WM RECEP. 11.0 20A/1P 17 18 20A/1P 4.0 LAB 573 HOOD VACUUM PUMP LAB 573 OVER COUNTER WM RECEP. 1.5 20A/1P 19 20 20A/1P 0.5 LAB 573 NAT. GAS. SHUT-OFF SOLENOID *SPARE 20A/1P 21 22 20A/1P *VARIAC #2 571 *'WIREMOLD 571 20A/1P 23 24 20A/1P *WIREMOLD 571 *'VAC PUMP TABLE #1 571 20A/1P 25 26 20A/1P *VAC PUMP TABLE #2 571 *EXISTING 20A/1P 27 28 20A/1P *EXISTING *EXISTING 20A/1P 29 30 20A/1P *EXISTING 23.5 3.5 20.0 SUBTOTAL (AMPS)24.5 10.5 9.1 PH. A PH. B PH.C TOTAL PHASE AMPS 48.00 14.00 29.10 * EXISTING LOAD TOTAL PHASE kVA 5.76 1.68 3.49 TOTAL 3-PHASE kVA 10.93 TOTAL DEMAND 3-PHASE kVA 10.93 TOTAL DEMAND 3-PHASE AMPS 30.38 PANELBOARD P-5D LOCATION: WRITE-UP 580 MAIN BUS AMPS: 100A SERVICE VOLTAGE: 208Y/120V, 3PH, 4W MAIN CIRCUIT BREAKER: NONE MOUNTING: RECESSED FEEDER SIZE: (4) #1/0, (1) #6 GND IN 2"C FEED: MAIN SWITCHBOARD FEED THRU LUGS: YES S.C. RATING: 10,000 AMPS RMS SYM. DESCRIPTION PHASE AMPS TRIP POLES TRIP PHASE AMPS DESCRIPTIONPH A PH B PH C AMPS AMPS PH A PH B PH C WRITE-UP 580 PERIM. WIREMOLD 4.5 20A/1P 1 2 20A/1P 6.0 LAB 580A FUME HOOD WRITE-UP 580 PERIM. WIREMOLD 4.5 20A/1P 3 4 20A/1P 6.0 LAB 580A BENCH WIREMOLD LAB 580A PERIM. WIREMOLD 4.5 20A/1P 5 6 20A/1P 4.5 LAB 580A PERIM. WIREMOLD LAB 580A BENCH WIREMOLD 6.0 20A/1P 7 8 20A/1P 3.0 WRITE-UP 580 PERIM. WIREMOLD LAB 580A VAV TRANSFORMER 1.0 20A/1P 9 10 20A/1P 9.0 WRITE-UP 580 COMPUTER WIREMOLD LAB 580A FUME HOOD 6.0 20A/1P 11 12 20A/1P 6.0 LAB 580A FUME HOOD LAB 580A BENCH WIREMOLD 6.0 20A/1P 13 14 20A/1P 6.0 LAB 580A BENCH WIREMOLD LAB 580A PERIM. WIREMOLD 3.0 20A/1P 15 16 20A/1P 3.0 LAB 580A OVER-COUNTER WIREMOLD LAB 580A PERIM. WIREMOLD 3.0 20A/1P 17 18 20A/1P 3.0 LAB 580A OVER-COUNTER WIREMOLD LAB 580A REFRIG. RECEP. 5.0 20A/1P 19 20 20A/1P 6.0 LAB 580A FUME HOOD LAB 580A DRYING OVEN RECEP. 14.0 20A/1P 21 22 20A/1P 4.0 LAB 580A HOOD VACUUM PUMP LAB 580A HOOD VACUUM PUMP 4.0 20A/1P 23 24 20A/1P 4.0 LAB 580A HOOD VACUUM PUMP LAB 580A HOOD VACUUM PUMP 4.0 20A/1P 25 26 20A/1P LAB 580A NAT. GAS. SHUT-OFF SOLENOID *EXISTING 20A/2P 27 28 20A/2P *EXISTING-29 30 -0.0 25.5 22.5 17.5 SUBTOTAL (AMPS)21.0 22.0 17.5 PH. A PH. B PH.C TOTAL PHASE AMPS 46.50 44.50 35.00 * EXISTING LOAD TOTAL PHASE kVA 5.58 5.34 4.20 TOTAL 3-PHASE kVA 15.12 TOTAL DEMAND 3-PHASE kVA 12.56 TOTAL DEMAND 3-PHASE AMPS 34.90 FLOOR MANUAL PULLSTATION. HEIGHT INDICATED IS TO TOP OF PULLSTATION COVER IF EQUIP. OTHERWISE HEIGHT INDICATES TOP OF DEVICE BACKBOX. WALL MOUNTED AUDIO/VISUAL OR VISUAL ONLY DEVICE. 4'-0" 6'-8" VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 10:51:53 AMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 RAM ELECTRICAL DETAILS & SCHEDULES AST DSU E-500 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020NO SCALE 1 TYPICAL FIRE ALARM ELEVATIONS 1234567891011121314 A B C D E 515 SF LAB 580A 53 SF WOMEN 500TB 63 SF MECH 500UD STAIR 500SE CORRIDOR 500CA 342 SF LAB 573 712 SF LAB 575 127 SF OFFICE 582 278 SF OFFICE 582A CS CS CS CS CS CS CS CS CS 1 1 2 VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 10:51:54 AMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 RAM FIFTH FLOOR PLAN - DEMO LIGHTING AST DSU ED-101 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020NORTH1/4" = 1'-0" 1 FIFTH FLOOR PLAN - DEMO LIGHTING DEMOLITION KEY NOTES 1. DISCONNECT AND REMOVE ALL EXISTING LIGHT FIXTURES AND ASSOCIATED CONTROL DEVICES IN THEIR ENTIRETY. DISCONNECT AND REMOVE BRANCH CIRCUITING BACK TO NEAREST JUNCTION BOX LOCATED OUTSIDE OF RENOVATION AREA AND SAVE FOR REUSE. 2. DISCONNECT AND REMOVE EXISTING WALL MOUNTED LIGHT FIXTURE TO ACCOMMODATE NEW FIRE WALL. SAVE AND PROTECT FIXTURE FOR RELOCATION. EXISTING BRANCH CIRCUITING SHALL REMAIN FOR REUSE. 1234567 A B C D E 515 SF LAB 580A 53 SF WOMEN 500TB 63 SF MECH 500UD STAIR 500SE CORRIDOR 500CA 342 SF LAB 573 712 SF LAB 575 127 SF OFFICE 582 278 SF OFFICE 582A 3 3 3 2 (TYP.) 1 1 (ETR) (ETR) WALL PHONE (ETR) (ETR) (ETR) (ETR) WAP WAP (ETR) WAP 5 4 C C (TYP. OF 5)(TYP. OF 5)(TYP. OF 5)(TYP. OF 5) 7 7 7 7 8 8 FUME HOOD FUME HOOD FUME HOOD 6 6 6 9 3 9 9 9 9 9 9 (ETR) (ETR) (ETR) P-5G P-5D L-5B 5 5 10 11 VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 10:51:55 AMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 RAM FIFTH FLOOR PLAN - DEMO POWER & TELECOM AST DSU ED-102 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 1/4" = 1'-0"1 FIFTH FLOOR PLAN - DEMO POWER NORTHDEMOLITION KEY NOTES 1. DISCONNECT AND REMOVE EXISTING DUPLEX RECEPTACLE FROM SINGLE COMPARTMENT RACEWAY AND PROVIDE BLANK COVERPLATE. EXISTING BRANCH CIRCUITING SHALL BE REMOVED BACK TO NEAREST COMMONLY FED DEVICE. 2. DISCONNECT AND REMOVE ALL EXISTING SINGLE COMPARTMENT RACEWAY WIRING DEVICES TO ACCOMMODATE DEVICE REPLACEMENTS. EXISTING BRANCH CIRCUITING SHALL REMAIN FOR REUSE. 3. DISCONNECT AND REMOVE EXISTING WIRING DEVICE TO ACCOMMODATE DEVICE REPLACEMENT. REFER TO DRAWING EP-101 FOR ADDITIONAL WORK. 4. DISCONNECT AND REMOVE EXISTING WIRELESS ACCESS POINT DATA OUTLET AND ASSOCIATED CABLING BACK TO SOURCE. ACCESS POINT SHALL BE REMOVED BY CORNELL CIT AND SAVED FOR RELOCATION. 5. DISCONNECT AND REMOVE EXISTING DATA OUTLET AND ASSOCIATED CABLING BACK TO SOURCE. 6. DISCONNECT AND REMOVE EXISTING FUME HOOD POWER BRANCH CIRCUITING AND HOOD MOUNTED RECEPTACLES BACK TO SOURCE. 7. DISCONNECT AND REMOVE EXISTING BENCHTOP RECEPTACLES AND ASSOCIATED BRANCH CIRCUITING BACK TO SOURCE. 8. DISCONNECT AND REMOVE EXISTING CEILING MOUNTED DUPLEX RECEPTACLES AND ASSOCIATED BRANCH CIRCUITING BACK TO SOURCE. 9. DISCONNECT AND REMOVE EXISTING DUPLEX RECEPTACLE FROM SINGLE COMPARTMENT RACEWAY TO ACCOMMODATE DEVICE REPLACEMENT AND RE- CIRCUITING. EXISTING BRANCH CIRCUITING SHALL BE REMOVED BACK TO NEAREST COMMONLY FED DEVICE. 10. DISCONNECT AND REMOVE EXISTING RECESSED RECEPTACLE. DISCONNECT AND REMOVE BRANCH CIRCUITING BACK TO SOURCE. EXISTING RECESSED BACKBOX SHALL REMAIN; PROVIDE NEW BLANK STAINLESS STEEL COVERPLATE. 11. DISCONNECT AND REMOVE EXISTING SURFACE MOUNTED RECEPTACLE IN ITS ENTIRETY. DISCONNECT AND REMOVE BRANCH CIRCUITING BACK TO SOURCE. DEMOLITION GENERAL NOTES 1. PRIOR TO DEMOLITION OF ANY TELECOMMUNICATION SYSTEM DEVICES, CONTACT CORNELL CIT OPERATIONS SUPPORT AT 607-255-5500 TO DISCONNECT ACTIVE SERVICES AND REMOVE HARDWARE FROM THE RENOVATION AREA. 123456789101112131415 A B C D E 515 SF LAB 580A 218 SF WRITE-UP 580 53 SF WOMEN 500TB 63 SF MECH 500UD STAIR 500SE CORRIDOR 500CA 342 SF LAB 573 127 SF OFFICE 582 278 SF OFFICE 582A CS CSCS CS CS CS CS CS CS DM DV V V DV B V MD D V B 1 1 EM EM EM ER ER2 2 LA a LB a LB a LB a LA a LA a LC c LC c LC c LC f LD b LD b LD b LD a LD a LA b LB b ER2 EM(ETR)(ETR)(ETR) (ETR) (ETR)(ETR) EM(ETR) (ETR) LE e LE e LE e LE e LF d 3 3 4 V B V B V B CS V ca d,e5 6 d,eLC ff LA b LB b ba b a VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 10:51:56 AMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 RAM FIFTH FLOOR PLAN - LIGHTING AST DSU EL-101 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 1/4" = 1'-0"1 FIFTH FLOOR PLAN - LIGHTING NORTHNEW WORK KEY NOTES 1. EXTEND AND RECONNECT EXISTING AREA LIGHTING CIRCUITS TO NEW LIGHT FIXTURES. PROVIDE ALL REQUIRED ROOM CONTROLLERS AND LOW VOLTAGE 0-10V WIRING TO CONTROL FIXTURES VIA INDICATED DIMMERS, SWITCHES AND SENSORS. 2. PROVIDE EMERGENCY RELAY UNIT TO ALLOW EMERGENCY LIGHT FIXTURES TO BE CONTROLLED BY LOCAL LIGHTING CONTROLS. IN THE EVENT OF A POWER OUTAGE, LIGHTING CONTROL SIGNALS SHALL BE BYPASSED AND LIGHT FIXTURES SHALL TURN ON TO FULL BRIGHTNESS. 3. PROVIDE ILLUMINATED EXIT SIGNS ABOVE NEW FIRE DOORS. EXIT SIGNS SHALL BE CONNECTED TO LOCAL FLOOR EXIT SIGN LIGHTING CIRCUIT (PHILIPS CHLORIDE CLX-AC-RW OR APPROVED CORNELL STANDARD EQUAL). 4. RELOCATE EXISTING 8-FOOT LIGHT FIXTURE TO ACCOMMODATE NEW FIRE DOOR. EXTEND AND RECONNECT EXISTING LIGHTING CIRCUIT TO RELOCATED FIXTURE. 5. PROVIDE LIGHTING CONTROL STATION CONSISTING OF ONE (1) PUSHBUTTON THAT SHALL CONTROL ON/OFF OPERATION OF BOTH SWITCHLEGS 'd' AND 'e' AND TWO (2) SEPARATE DIMMERS, ONE (1) FOR FIXTURES ON SWITCHLEG 'd' AND ONE (1) FOR FIXTURES ON SWITCHLEG 'e'. 6. PROVIDE LIGHTING CONTROL STATION CONSISTING OF ONE (1) PUSHBUTTON THAT SHALL CONTROL ON/OFF OPERATION OF BOTH SWITCHLEGS 'd' AND 'e'. GENERAL NOTES 1. PROVIDE FIRESTOPPING OF ALL RACEWAY AND SLEEVE PENETRATIONS. 2. ALL NEW RACEWAY INSTALLED IN CORRIDOR 500CA SHALL BE PAINTED BLACK TO MATCH EXISTING RACEWAY. 123456789101112131415 A B C D E 515 SF LAB 580A 218 SF WRITE-UP 580 53 SF WOMEN 500TB 63 SF MECH 500UD STAIR 500SE CORRIDOR 500CA 342 SF LAB 573 127 SF OFFICE 582 278 SF OFFICE 582A 1 FUME HOOD FUME HOOD 1 2 3 4 4 REFRIGERATOR GFI GFI GFI GFI GFI GFI GFI GFI GFI GFI GFI GFI GFI GFI 222 5 GFI GFI GFIGFI 6T P-5D L-5B P-5G FUME HOOD 4 GLASSWARE OVEN CARVER PRESS TENSILE TESTER REFRIGERATOR GFI GFIGFI GFI GFIGFI GFI 2 2 ROTO VAP 7 6 T (ETR) (ETR) (ETR)P-5D-21 P-5D-16 P-5D-20 P-5D-19 EAV-6 CAV-2 EAV-8 EAV-7 SAV-2 SAV-1 EAV-1 EAV-2 EAV-3 EAV-4 CAV-1 EAV-5 CAV-3 P-5D-9 P-5D-14 P-5D-13 P-5D-7 P-5D-4 P-5D-12 P-5D-11 P-5D-10 L-5B-13 P-5G-6 P-5G-5 P-5G-7 P-5G-9 P-5G-2 P-5G-4 P-5G-19 P-5G-17 7 7 7 7 P-5G-8 P-5G-1 P-5G-3 P-5G-10 8 8 8 8888 P-5D-18 9 14 14 13 13 13 13 14 14 GFI GFI GFI 7 7 4 4 4 4 7 7 18 1816 16 7 5 7 5 5 7 5 7 10 10 10 10 10 10 17 13 48" A.F.F.P 13 17 13 10 L-5B-17 GFI 7 11 12 13 DH DH NAC P-5G-10 P-5G-11 14 E LAB 580A NATURAL GAS EMERGENCY SHUT-OFF SOLENOID E LAB 573 NATURAL GAS EMERGENCY SHUT-OFF SOLENOID P-5D-2 171515 15 15 GFI 16 16 16 16 P-5D-22 P-5D-24 17 P-5G-14 P-5D-23 P-5G-18 P-5G-20 P-5D-26 16 16 13 MECH 500UC ELEVATOR 500EB ELEVATOR 500EA MECH 500UB MECH 500UE LAB 571LAB 565 LAB 570 WRITE-UP 570A WRITE-UP 572A LAB 572 15 P-5D-25 VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 10:51:57 AMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 RAM FIFTH FLOOR PLAN - POWER AST DSU EP-101 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 1/4" = 1'-0" 1 FIFTH FLOOR PLAN - POWER NORTHNEW WORK KEY NOTES (CONTINUED) 5. PROVIDE 3000 SERIES STEEL WIREMOLD RACEWAY WITH QUANTITY AND TYPES OF RECEPTACLES INDICATED ABOVE COUNTERTOP. 6. PROVIDE 300VA, CLASS II, 120VAC PRIMARY, 24VAC SECONDARY TRANSFORMER WITH MANUAL RESET OVERLOAD FOR AIR VALVE, AIR TERMINAL AND DIGITAL CONTROLLER 24VAC POWER (DESIGN MAKE: RIB MODEL #PSH300A OR APPROVED EQUAL). PROVIDE 1-POLE LOCKABLE MAINTENANCE SWITCH AT EACH TRANSFORMER LOCATION. PROVIDE ALL CLASS II, 24VAC, WIRING BETWEEN TRANSFORMER AND INDICATED LOW VOLTAGE DEVICES UTILIZING 16/2 TWISTED PAIR CABLES. TRANSFORMER AND MAINTENANCE SWITCH SHALL BE WALL MOUNTED NEAR ROOM CEILING IN AN ACCESSIBLE LOCATION. 7. REPLACE EXISTING WIRING DEVICE AND ASSOCIATED COVERPLATE WITH NEW. EXISTING BRANCH CIRCUITING SHALL BE RECONNECTED TO REPLACEMENT DEVICE. 8. REPLACE EXISTING WIRING DEVICE AND ASSOCIATED COVERPLATE IN EXISTING RACEWAY WITH NEW AND RE-FEED FROM CIRCUIT INDICATED. 9. LABEL RECEPTACLE "DEDICATED FOR OVEN". 10. PROVIDE DUPLEX RECEPTACLE IN NEW FLUSH MOUNTED POKE-THRU. REFER TO DRAWING ET-101 FOR ADDITIONAL POKE-THRU DEVICE REQUIREMENTS. 11. PROVIDE DUPLEX GFI TYPE RECEPTACLE MOUNTED ON SIDE OF FUME HOOD JUST ABOVE COUNTERTOP (35" A.F.F. - BOTTOM OF RECEPTACLE). 12. RELOCATE TWO (2) EXISTING JUNCTION BOXES TO ACCOMMODATE NEW FIRE DOORS. EXTEND AND RECONNECT ALL AFFECTED BRANCH CIRCUITING. 13. PROVIDE FIRESTOPPING AROUND ALL EXISTING CONDUITS PENETRATING NEW FIRE RATED WALL ABOVE FIRE DOORS. 14. RECEPTACLE SHALL BE MOUNTED BEHIND WALL MOUNTED MONITOR. COORDINATE EXACT MOUNTING HEIGHT WITH CORNELL AVC PRIOR TO ROUGHING-IN. 15. PROVIDE POWER CONNECTION TO HOOD VACUUM PUMP CONTROL SYSTEM. SYSTEM CONSISTS OF A FACTORY INSTALLED CONTROLLED RECEPTACLE LOCATED INSIDE OF THE VACUUM PUMP CABINET THAT IS PRE-WIRED TO A FACTORY MOUNTED TOGGLE SWITCH ON EXTERIOR OF CABINET DOOR. 16. ALTERNATE: PROVIDE BREAK-GLASS TYPE EMERGENCY SHUT-OFF PUSHBUTTON (PILLA MODEL #ST120) TO CONTROL NATURAL GAS EMERGENCY SHUT-OFF SOLENOID. IN THE EVENT THE BREAK-GLASS RELEASE BUTTON IS RELEASED THE NORMALLY OPEN CONTACT SHALL DROP OUT POWER TO THE SOLENOID, SHUTTING OFF GAS TO THE LAB. PROVIDE 2#12 IN 3/4"C BETWEEN PUSHBUTTON N.O. CONTACTS AND SOLENOID. ALTERNATE INCLUDES ALL 120V BRANCH CIRCUITING ASSOCIATED WITH SOLENOID. 17. PROVIDE POWER CONNECTION TO ADA HOOD VACUUM PUMP CONTROL SYSTEM. SYSTEM CONSISTS OF A FACTORY INSTALLED CONTROLLED RECEPTACLE LOCATED INSIDE OF THE VACUUM PUMP CABINET AND A REMOTE FACTORY MOUNTED TOGGLE SWITCH MOUNTED ON PLATE BELOW ADA FUME HOOD. ELECTRICAL CONTRACTOR SHALL PROVIDE 2#12, 1#12 GND BETWEEN SWITCH AND RECEPTACLE; COORDINATE ROUTING WITH CORNELL PROJECT MANAGER PRIOR TO INSTALLATION. GENERAL NOTES 1. PROVIDE FIRESTOPPING OF ALL RACEWAY AND SLEEVE PENETRATIONS. 2. ALL NEW RACEWAY INSTALLED IN CORRIDOR 500CA SHALL BE PAINTED BLACK TO MATCH EXISTING RACEWAY. NEW WORK KEY NOTES 1. REPLACE ALL EXISTING WIRING DEVICES AND ASSOCIATED COVERPLATES IN EXISTING RACEWAY WITH NEW. UNLESS NOTED OTHERWISE, EXISTING BRANCH CIRCUITING SHALL BE RECONNECTED TO REPLACEMENT DEVICES. 2. PROVIDE 3000 SERIES STEEL WIREMOLD RACEWAY WITH QUANTITY AND TYPES OF RECEPTACLES INDICATED BETWEEN LAB BENCH POSTS. REFER TO LAB BENCH ELEVATIONS IN A-SERIES DRAWINGS FOR EXACT LOCATION OF RACEWAY. 3. PROVIDE 4000 SERIES STEEL DUAL-COMPARTMENT WIREMOLD RACEWAY, MOUNTED ABOVE NEW COUNTERTOP, FOR COMPUTER WORKSTATION DATA AND POWER OUTLETS (BOTTOM OF RACEWAY 31" A.F.F.). RACEWAY SHALL BE SHOP PAINTED TO MATCH STOREFRONT FINISH. 4. PROVIDE POWER CONNECTION(S) FOR FUME HOOD. FEFEFE 1234567891011121314 A B C D E WAP (ETR) (ETR) WALL PHONE (ETR) (ETR) (RELOCATED) 2 2 2 (ETR) 1 1 1 2 CABLE TRAY (ETR) TWO (2) 1-1/2"C & ONE (1) 3/4"C (ETR) TWO (2) 1-1/2"C & ONE (1) 3/4"C (ETR) TWO (2) 1-1/2"C & ONE (1) 3/4"C (ETR) FOUR (4) 4"C & TWO (2) 2"C (ETR) EXISTING SLEEVE IN CEILING UP TO 6TH FLOOR MECH. RM. . EXISTING TELECOM CABINET IS LOCATED DIRECTLY ADJACENT TO SLEEVE IN 6TH FLOOR MECH. RM. (ETR) WAP (ETR) WAP(ETR) WAP 2 ONE (1) 1-1/4"C FLUSH MOUNTED POKE-THRU 2 4J ONE (1) 1"C ROUTED ABOVE 4TH FLOOR DROP CEILING A/V OUTLET BOX 5 7 6 67 8 99 4 3 3 P WAP C WAP C OFFICE 582A LAB 580A WRITE-UP 580 OFFICE 582 LAB 573 STAIR 500SE MECH 500UDWOMEN 500TB CORRIDOR 500CA LAB 575LAB 571MECH 500UE MECH 500UB ELEVATOR 500EA ELEVATOR 500EB MECH 500UC LAB 572 WRITE-UP 572A WRITE-UP 570A LAB 570 2 2 OC OC VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 10:51:58 AMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 RAM FIFTH FLOOR PLAN - TELECOM AST DSU ET-101 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 1/4" = 1'-0" 1 FIFTH FLOOR PLAN - TELECOMMUNICATION NORTHNEW WORK KEY NOTES 1. PROVIDE DATA OUTLETS IN DUAL COMPARTMENT RACEWAY. 2. PROVIDE TWO (2) NEW WALL MOUNTED CAT 6A DATA OUTLETS FOR RELOCATED WIRELESS ACCESS POINT. ACCESS POINT SHALL BE RELOCATED AND RE- INSTALLED BY CORNELL CIT. 3. PROVIDE TWO (2) CAT 6A DATA OUTLETS ABOVE DROP CEILING FOR NEW CEILING MOUNTED WIRELESS ACCESS POINT. ACCESS POINT SHALL BE FURNISHED AND INSTALLED BY CORNELL CIT. COORDINATE FINAL LOCATION OF OUTLETS WITH CORNELL CIT PRIOR TO ROUGHING IN. 4. PROVIDE TWO (2) WALL MOUNTED CAT 6A DATA OUTLETS FOR NEW WALL MOUNTED WIRELESS ACCESS POINT. ACCESS POINT SHALL BE FURNISHED AND INSTALLED BY CORNELL CIT. COORDINATE FINAL LOCATION OF OUTLETS WITH CORNELL CIT PRIOR TO ROUGHING IN. 5. PROVIDE 8-INCH, FLUSH MOUNTED, POKE-THRU FOR CONFERENCE TABLE A/V, POWER AND DATA CONNECTIONS (DESIGN MAKE: LEGRAND 8AT EVOLUTION SERIES OR APPROVED EQUAL). COVERPLATE FINISH SHALL BE SELECTED BY ARCHITECT. 6. PROVIDE QUANTITY OF DATA OUTLETS INDICATED IN FLUSH MOUNTED POKE- THRU. DATA CABLING SHALL BE ROUTED IN 1"C FROM POKE-THRU TO SURFACE MOUNTED DATA OUTLET, LOCATED BEHIND WALL MOUNTED MONITOR, THEN CONTINUE UP TO ABOVE CEILING AND ON TO DATA RACK. COORDINATE EXACT MOUNTING HEIGHT OF WALL MOUNTED DATA OUTLET WITH CORNELL AVC PRIOR TO ROUGHING-IN. 7. PROVIDE 1-1/4"C RACEWAY FROM POKE-THRU TO SURFACE MOUNTED A/V OUTLET BOX LOCATED BEHIND WALL MOUNTED MONITOR. BOX SHALL BE PROVIDED BY CORNELL AVC. POKE-THRU AND WALL MOUNTED OUTLET BOX A/V OUTLETS AND ASSOCIATED A/V CABLING SHALL BE PROVIDED BY CORNELL AVC. 8. PROVIDE TWO (2) RETRO-FIT FIRESTOPPING DEVICES AROUND EXISTING DATA CABLING ROUTED THROUGH NEW FIRE WALL (STI EZ-PATH SERIES 44+, #EZDP144RS2). 9. DISCONNECT AND REMOVE PORTION OF EXISTING CABLETRAY TO ACCOMMODATE NEW FIRE WALL. TEMPORARILY SUPPORT EXISTING CABLES ON EITHER SIDE OF WALL WHILE WALL IS BEING BUILT. UPON COMPLETION OF WALL, EXTEND REMAINING PORTIONS OF EXISTING CABLETRAY BACK TO WALL. GENERAL NOTES 1. PROVIDE, ROUTE AND TERMINATE ALL HORIZONTAL DATA CABLING FROM DATA OUTLET BACK TO EXISTING DATA RACK IN 6TH FLOOR TELECOMMUNICATION ROOM. UTILIZE EXISTING ABOVE CEILING CABLETRAYS IN CORRIDOR TO ROUTE CABLING BACK TO CLOSET. COORDINATE FINAL TERMINATIONS AND TESTING WITH OWNER. 2. PROVIDE FIRESTOPPING OF ALL RACEWAY AND SLEEVE PENETRATIONS. FACP (ETR) 3/4"C (TYP.)UP THROUGH CONCRETE FLOOR LOCATION OF EXISTING ACCESS DOOR (ETR)3/4"C UP THROUGH CONCRETE FLOOR 13/4"C UP THROUGH CONCRETE FLOOR LOCATION OF EXISTING ACCESS DOOR (ETR) 1 3/4"C UP THROUGH CONCRETE FLOOR 1 3/4"C UP THROUGH CONCRETE FLOOR 1 3/4"C UP THROUGH CHASE 1 3/4"C UP THROUGH CHASE 1 NEW NAC PANEL 3/4"C 3/4"C UP THROUGH CHASE 1 2 VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 10:51:59 AMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 RAM KEY PLANS - FIRE ALARM AST DSU FA-001 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 1/32"=1'-0" 1 SUB-BASEMENT PLAN 1/32"=1'-0" 3 GROUND FLOOR PLAN 1/32"=1'-0" 2 BASEMENT PLAN 1/32"=1'-0" 4 FIRST FLOOR PLAN 1/32"=1'-0"5 SECOND FLOOR PLAN 1/32"=1'-0"6 THIRD FLOOR PLAN 1/32"=1'-0"7 FOURTH FLOOR PLAN 1/32"=1'-0"8 FIFTH FLOOR PLAN GENERAL NOTES 1. PROVIDE FIRESTOPPING OF ALL RACEWAY AND SLEEVE PENETRATIONS. 2. ELECTRICAL CONTRACTOR SHALL PROVIDE CORING OF ALL CONCRETE FLOORS TO ACCOMMODATE NEW RACEWAY. NEW WORK KEY NOTES 1. PROVIDE NOTIFICATION APPLIANCE CIRCUIT FIRE ALARM CABLE IN 3/4" EMT RACEWAY FROM EXISTING SUB-BASEMENT FIRE ALARM CONTROL PANEL TO NEW 5TH FLOOR NAC PANEL. PROVIDE 4" X4" JUNCTION BOX ON EACH FLOOR TO PROVIDE FUTURE ACCESS TO RACEWAY. COORDINATE EXACT SIZE AND TYPE OF CABLE REQUIRED WITH EXISTING FIRE ALARM SYSTEM MANUFACTURER. 2. ALL EXPOSED RACEWAY IN CORRIDOR SHALL BE PAINTED BLACK TO MATCH SURROUNDING RACEWAY. FIRE ALARM JUNCTION BOX COVERS SHALL BE RED.NORTH P 123456789101112131415161718192021 A B C D E Ƨ Ƨ Ƨ (RELOCATED) (ETR) (ETR) (RELOCATED) (ETR)(ETR) 1 1 1 2 3 3 FS AUTO TEST FLOW SWITCH NAC Ƨ4 2 ACM AM 5 5 DH DH ACM 6 6 6 Ƨ 2 Ƨ 2 60 60 30 OFFICE 560A LAB 580A P.I. OFFICE 582A STAIR 500SB MECH 500UD LAB 575 OFFICE 582 WRITE-UP 562A LAB 562 MENS' 500TA ELEVATOR 500EAMECH 500UA STAIR 500SA LAB 570 WRITE-UP 570A WRITE-UP 572A LAB 572 CONFERENCE 561 OFFICE 560 WRITE-UP 563 LAB 565 MECH 500UE LAB 571 MECH 500UB ELEVATOR 500EB MECH 500UC Room 550J Room 569 CORRIDOR 500CA WRITE-UP 580 WOMEN 500TB CORRIDOR 500CA LAB 573 LAB 575 VERIFY SCALE BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING: IF BAR IS NOT ONE (1) INCH LONG, ADJUST SCALE ACCORDINGLY 0 1 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com5/22/2020 10:52:00 AMC:\Users\monom\Documents\Revit 2019\19621_MEP_Central_v2019_monomCVV2R.rvt19700.00 RAM FIFTH FLOOR PLAN - FIRE ALARM AST DSU FA-101 100% Construction Documents Cornell University S.T. Olin Chemistry Research Wing -Chem Lab 573-580 Renovation Facilities & Campus Services - Humphreys Service Building, Ithaca, NY 14853 05/22/2020 1/8" = 1'-0" 1 FIFTH FLOOR PLAN - FIRE ALARM NORTHGENERAL NOTES 1. PROVIDE FIRESTOPPING OF ALL RACEWAY AND SLEEVE PENETRATIONS. 2. ALL NEW RACEWAY INSTALLED IN CORRIDOR 500CA SHALL BE PAINTED BLACK TO MATCH EXISTING RACEWAY. FIRE ALARM JUNCTION BOX COVERS SHALL BE RED. 3. PROVIDE TEMPORARY SUPPORT OF ALL DEVICES INDICATED AS EXISTING TO REMAIN (ETR) LOCATED IN CEILINGS THAT ARE TO BE REPLACED. NEW WORK KEY NOTES 1. PROVIDE FIRE ALARM NOTIFICATION DEVICE AT THE LOCATION SHOWN. DEVICE SHALL BE CONNECTED TO NEW NOTIFICATION APPLIANCE CIRCUIT. 2. PROVIDE FIRE ALARM INITIATION DEVICE AT THE LOCATION SHOWN. DEVICE SHALL BE CONNECTED TO NEAREST EXISTING INITIATION CIRCUIT. 3. RELOCATE EXISTING FIRE ALARM DEVICE TO ACCOMMODATE NEW DUCT WORK. EXTEND AND RECONNECT EXISTING FIRE ALARM BRANCH CIRCUITING TO RELOCATED DEVICE. 4. PROVIDE NEW NOTIFICATION APPLIANCE CIRCUIT (NAC) PANEL IN EXISTING MECHANICAL ROOM TO POWER NEW 5TH FLOOR NOTIFICATION DEVICES AND FIRE PROTECTION SYSTEM AUTO TEST FLOW SWITCH. COORDINATE EXACT LOCATION OF NAC PANEL WITH EXISTING EQUIPMENT LAYOUT WITHIN ROOM. PANEL SHALL BE CONNECTED TO EXISTING BUILDING FIRE ALARM SYSTEM CONTROL PANEL (FACP) IN SUB-BASEMENT. REFER TO DRAWING FA-001 FOR PROPOSED PATHWAY FROM SUB-BASEMENT FACP UP TO NAC PANEL. 5. PROVIDE ADDRESSABLE MONITOR MODULE AND ADDRESSABLE CONTROL MODULE FOR AUTO TEST FLOW SWITCH (PROVIDED BY FIRE PROTECTION CONTRACTOR). FLOW SWITCH SHALL BE POWERED BY 24 VDC CIRCUIT FROM NEW NAC PANEL. 6. PROVIDE ADDRESSABLE CONTROL MODULE TO CONTROL NEW 120V MAGNETIC DOOR HOLDERS. DOOR HOLDERS SHALL BE FURNISHED WITH DOOR HARDWARE, INSTALLED BY ELECTRICAL CONTRACTOR.