Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20-242 CALCS stamped
Hydraulic Calculations Location: 323 ELMIRA ROAD, ITHACA, NY 14850, Project Name: BYRNE DAIRY Drawing Name: BYRNE DAIRY FP Calculation Date: 10/19/2020 for Design Remote Area Location: Ordinary Group II Area of Application: 1500ft² (Actual 999ft²) Coverage per Sprinkler: 130ft² Type of sprinklers calculated: 14 STORE AREA 1Remote Area Number: Occupancy Classification: No. of sprinklers calculated: Density 0.20gpm/ft² Pendent No. of nozzles calculated: 0 In-rack Demand: Hose Streams:at Node:Type:Allowance at Source N/Aat Node:N/A gpm 1250.00 (including Hose Streams where applicable):Total Water Required 75.689@628.85From Water Supply at Node 1:(Safety Margin = 11.439 psi) Type of System: Volume of Dry or PreAction System:4.55gal Source: ITHACA FIRE DEPARTMENT Location: Date:for Node: 1 Name of Contractor: ITHACA FIRE DEPARTMENTAuthority Having Jurisdiction: Address: Phone Number: Name of designer: , Nolan Alley Notes: 10/19/2020© M.E.P.CAD, Inc.Page 1AutoSPRINK 2019 v15.1.20.0 11:20:24AM1 Hydraulic Graph Water Supply Node: 1 Job Name: BYRNE DAIRY Remote Area Number: 1 Date: 10/19/2020 Summary Sheet N 1.85 © M.E.P.CAD, Inc.10/19/2020 Page 2AutoSPRINK 2019 v15.1.20.0 11:20:26AM Hydraulic Graph B.O.R. Job Name: BYRNE DAIRY Remote Area Number: 1 Date: 10/19/2020 Summary Sheet N 1.85 © M.E.P.CAD, Inc.10/19/2020 Page 3AutoSPRINK 2019 v15.1.20.0 11:20:26AM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Ordinary Group II (1 ) Job Number: 20-242 Sprinkler S201 31.67 24.00 5.6 31.990 Sprinkler S202 30.95 24.00 5.6 30.548 Sprinkler S203 29.90 24.00 5.6 28.512 Sprinkler S204 27.68 24.00 5.6 24.437 Sprinkler S205 27.38 24.00 5.6 23.903 Sprinkler S206 27.48 24.00 5.6 24.088 Sprinkler S207 25.99 24.00 5.6 21.536 Sprinkler S208 27.00 24.00 5.6 23.245 Sprinkler S209 24.64 14.82 5.6 19.362 Sprinkler S210 25.76 24.00 5.6 21.153 Sprinkler S211 27.41 19.20 5.6 23.952 Sprinkler S212 24.00 24.00 5.6 18.367 Sprinkler S213 24.69 18.80 5.6 19.443 Sprinkler S214 24.29 24.00 5.6 18.813 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.10/19/2020 Page 4AutoSPRINK 2019 v15.1.20.0 11:20:28AM Job Name: BYRNE DAIRY Remote Area Number: 1 Date: 10/19/2020 Node @ @ Supply Analysis Static (psi) Required Pressure (psi)(gpm) Total DemandAvailable (psi) Flow (gpm) Residual (psi)Name 54.0001 75.689628.851750.00 87.12893.000Water Supply Node Analysis NotesDischarge at Node (gpm) Pressure at Node (psi) Node TypeElevation (Foot)Node Number -5'-0 378.8575.689Supply1 9'-9 31.6731.990SprinklerS201 9'-9 30.9530.548SprinklerS202 9'-9 29.9028.512SprinklerS203 9'-9 27.6824.437SprinklerS204 9'-9 27.3823.903SprinklerS205 9'-9 27.4824.088SprinklerS206 9'-9 25.9921.536SprinklerS207 9'-9 27.0023.245SprinklerS208 9'-8½24.6419.362SprinklerS209 9'-9 25.7621.153SprinklerS210 9'-9 27.4123.952SprinklerS211 9'-9 24.0018.367SprinklerS212 9'-8 24.6919.443SprinklerS213 9'-9 24.2918.813SprinklerS214 -5'-0 75.6742 10'-2 52.0673 10'-2 52.1194 10'-2 52.6575 © M.E.P.CAD, Inc.10/19/2020 Page 5AutoSPRINK 2019 v15.1.20.0 11:20:32AM Job Name: BYRNE DAIRY Remote Area Number: 1 Date: 10/19/2020 NotesDischarge at Node (gpm) Pressure at Node (psi) Node TypeElevation (Foot)Node Number 10'-2 43.0806 10'-2 41.1677 10'-2 38.4658 10'-2 33.0429 10'-2 57.82510 10'-2 32.33111 10'-2 32.57712 10'-2 29.17113 10'-2 27.62114 10'-2 24.02115 10'-2 22.66016 10'-2 25.69817 2'-6 71.29318 2'-6 70.43319 © M.E.P.CAD, Inc.10/19/2020 Page 6AutoSPRINK 2019 v15.1.20.0 11:20:32AM Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 1 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-FactorElev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 32'-0 10'-2 32'-0 -0.181 5.835 9'-9 0'-0S212 15 1 • • • • • Route 1 • • • • •(See Notes) 1.0490 18.36724.00 0.182334 Sprinkler, 24.00 5.6 , fd(32'-0) 120 10'-2 2'-6 3.599 10'-2 2'-615 14 1 1.0490 24.02149.33 1.439773 Flow (q) from Route 9 73.33 120 10'-2 7'-6 4.956 10'-2 7'-614 12 1¼ 1.3800 27.62125.76 0.660839 Flow (q) from Route 3 99.09 120 10'-2 12'-0 5.888 10'-2 12'-012 8 1½ 1.6100 32.57727.48 0.490627 Flow (q) from Route 7 126.57 120 8'-0 10'-2 19'-6½14.193 10'-2 11'-6½8 5 1½(See Notes) 1.6100 38.46529.90 0.726346 Flow (q) from Route 10 156.48 PO(8'-0) 120 6'-8½ 10'-2 43'-0½5.167 10'-2 36'-45 10 3 (See Notes) 3.2600 52.657222.37 0.120071 Flow (q) from Route 2 378.85 fE(6'-8½) 120 51'-1 2'-6 104'-5 3.318 9.290 10'-2 53'-3½10 19 4 (See Notes) 4.2600 57.825 0.032627378.85 fE(8'-11½), BV(15'-9½), PO(26' -4), BFP(-5.884), B.O.R. 120 26'-4 2'-6 26'-4 0.859 2'-6 0'-019 18 4 (See Notes) 4.2600 70.433 0.032627378.85 T(26'-4) 120 91'-5 -5'-0 303'-5½ 3.257 1.125 2'-6 212'-0½18 2 6 (See Notes) 6.2800 71.293 0.003706378.85 2E(22'-1), T(47'-3½) 140 -5'-0 115'-7 0.015 -5'-0 115'-72 1 12 (See Notes) 12.4600 75.674 0.000132378.85 Water Supply 140 1 250.00 Hose Allowance At Source 628.85 Route 1Total(Pt) 75.689 © M.E.P.CAD, Inc.10/19/2020 Page 7AutoSPRINK 2019 v15.1.20.0 11:20:35AM1 Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 1 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-FactorElev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 32'-0 10'-2 37'-11 -0.181 7.066 9'-9 5'-11S214 17 1 • • • • • Route 2 • • • • •(See Notes) 1.0490 18.81324.29 0.186421 Sprinkler, 24.29 5.6 , fd(32'-0) 120 10'-2 4'-7½3.473 10'-2 4'-7½17 13 1 1.0490 25.69827.41 0.754001 Flow (q) from Route 12 51.70 120 10'-2 7'-6 3.159 10'-2 7'-613 11 1¼ 1.3800 29.17125.99 0.421261 Flow (q) from Route 4 77.68 120 10'-2 12'-0 8.837 10'-2 12'-011 7 1¼ 1.3800 32.33127.38 0.736411 Flow (q) from Route 6 105.06 120 8'-0 10'-2 19'-6½10.951 10'-2 11'-6½7 4 1½(See Notes) 1.6100 41.16730.95 0.560453 Flow (q) from Route 11 136.01 PO(8'-0) 120 10'-2 12'-0½0.539 10'-2 12'-0½4 5 3 3.2600 52.11986.36 0.044810 Flow (q) from Route 5 222.37 120 52.657 Total(Pt)Route 2 32'-0 10'-2 32'-0 -0.181 6.649 9'-9 0'-0S210 14 1 • • • • • Route 3 • • • • •(See Notes) 1.0490 21.15325.76 0.207773 Sprinkler, 25.76 5.6 , fd(32'-0) 120 27.621 Total(Pt)Route 3 37'-0 10'-2 37'-0 -0.181 7.816 9'-9 0'-0S207 13 1 • • • • • Route 4 • • • • •(See Notes) 1.0490 21.53625.99 0.211248 Sprinkler, 25.99 5.6 T(5'-0), fd(32'-0) 120 29.171 Total(Pt)Route 4 32'-0 10'-2 44'-0 -0.181 9.978 9'-9 12'-0S208 9 1 • • • • • Route 5 • • • • •(See Notes) 1.0490 23.24527.00 0.226710 Sprinkler, 27.00 5.6 , fd(32'-0) 120 10'-2 12'-0 10.038 10'-2 12'-09 6 1 1.0490 33.04227.68 0.836538 Flow (q) from Route 8 54.68 120 © M.E.P.CAD, Inc.10/19/2020 Page 8AutoSPRINK 2019 v15.1.20.0 11:20:35AM1 Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 1 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-FactorElev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 6'-0 10'-2 17'-6½8.987 10'-2 11'-6½6 3 1¼(See Notes) 1.3800 43.08031.67 0.512359 Flow (q) from Route 14 86.36 PO(6'-0) 120 10'-2 6'-8 0.052 10'-2 6'-83 4 3 3.2600 52.067 0.00778886.36 120 52.119 Total(Pt)Route 5 37'-0 10'-2 37'-0 -0.181 8.608 9'-9 0'-0S205 11 1 • • • • • Route 6 • • • • •(See Notes) 1.0490 23.90327.38 0.232647 Sprinkler, 27.38 5.6 T(5'-0), fd(32'-0) 120 32.331 Total(Pt)Route 6 37'-0 10'-2 37'-0 -0.181 8.670 9'-9 0'-0S206 12 1 • • • • • Route 7 • • • • •(See Notes) 1.0490 24.08827.48 0.234312 Sprinkler, 27.48 5.6 T(5'-0), fd(32'-0) 120 32.577 Total(Pt)Route 7 37'-0 10'-2 37'-0 -0.181 8.785 9'-9 0'-0S204 9 1 • • • • • Route 8 • • • • •(See Notes) 1.0490 24.43727.68 0.237445 Sprinkler, 27.68 5.6 T(5'-0), fd(32'-0) 120 33.042 Total(Pt)Route 8 6'-0 10'-2 17'-10½ -0.217 3.433 9'-8 11'-10½S213 16 1 • • • • • Route 9 • • • • •(See Notes) 1.0490 19.44324.69 0.192193 Sprinkler, 24.69 5.6 3E(2'-0) 120 10'-2 1'-11½1.361 10'-2 1'-11½16 15 1 1.0490 22.66024.64 0.691514 Flow (q) from Route 13 49.33 120 24.021 Total(Pt)Route 9 37'-0 10'-2 37'-0 -0.181 10.133 9'-9 0'-0S203 8 1 • • • • • Route 10 • • • • •(See Notes) 1.0490 28.51229.90 0.273861 Sprinkler, 29.90 5.6 T(5'-0), fd(32'-0) 120 38.465 Total(Pt)Route 10 37'-0 10'-2 37'-0 -0.181 10.800 9'-9 0'-0S202 7 1 • • • • • Route 11 • • • • •(See Notes) 1.0490 30.54830.95 0.291898 Sprinkler, 30.95 5.6 T(5'-0), fd(32'-0) 120 © M.E.P.CAD, Inc.10/19/2020 Page 9AutoSPRINK 2019 v15.1.20.0 11:20:35AM1 Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 1 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-FactorElev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 41.167 Total(Pt)Route 11 7'-0 10'-2 8'-3 -0.181 1.927 9'-9 1'-3S211 17 1 • • • • • Route 12 • • • • •(See Notes) 1.0490 23.95227.41 0.233083 Sprinkler, 27.41 5.6 E(2'-0), T(5'-0) 120 25.698 Total(Pt)Route 12 11'-0 10'-2 18'-3½ -0.208 3.506 9'-8½7'-3½S209 16 1 • • • • • Route 13 • • • • •(See Notes) 1.0490 19.36224.64 0.191449 Sprinkler, 24.64 5.6 3E(2'-0), T(5'-0) 120 22.660 Total(Pt)Route 13 37'-0 10'-2 37'-0 -0.181 11.271 9'-9 0'-0S201 6 1 • • • • • Route 14 • • • • •(See Notes) 1.0490 31.99031.67 0.304620 Sprinkler, 31.67 5.6 T(5'-0), fd(32'-0) 120 43.080 Total(Pt)Route 14 © M.E.P.CAD, Inc.10/19/2020 Page 10AutoSPRINK 2019 v15.1.20.0 11:20:35AM1 Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 1 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90°cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90°Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 4.87 )(150 1.33 140 1.16 130 0.713 100Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.10/19/2020 Page 11AutoSPRINK 2019 v15.1.20.0 11:20:35AM1 Hydraulic Calculations Location: 323 ELMIRA ROAD, ITHACA, NY 14850, Project Name: BYRNE DAIRY Drawing Name: BYRNE DAIRY FP Calculation Date: 10/19/2020 for Design Remote Area Location: Light Hazard Area of Application: 1500ft² (Actual 649ft²) Coverage per Sprinkler: 130ft² Type of sprinklers calculated: 6 ATTIC (PEAK) 2Remote Area Number: Occupancy Classification: No. of sprinklers calculated: Density 0.10gpm/ft² Upright No. of nozzles calculated:0 In-rack Demand: Hose Streams:at Node:Type:Allowance at Source N/Aat Node:N/A gpm 1100.00 (including Hose Streams where applicable):Total Water Required 76.232@229.03From Water Supply at Node 1:(Safety Margin = 15.862 psi) Type of System: Volume of Dry or PreAction System:80.60gal Source:ITHACA FIRE DEPARTMENT Location: Date:for Node:1 Name of Contractor: ITHACA FIRE DEPARTMENTAuthority Having Jurisdiction: Address: Phone Number: Name of designer: , Nolan Alley Notes: 10/19/2020© M.E.P.CAD, Inc.Page 1AutoSPRINK 2019 v15.1.20.0 11:19:48AM2 Hydraulic Graph Water Supply Node: 1 Job Name: BYRNE DAIRY Remote Area Number: 2 Date: 10/19/2020 Summary Sheet N 1.85 © M.E.P.CAD, Inc.10/19/2020 Page 2AutoSPRINK 2019 v15.1.20.0 11:19:51AM Hydraulic Graph B.O.R. Job Name: BYRNE DAIRY Remote Area Number: 2 Date: 10/19/2020 Summary Sheet N 1.85 © M.E.P.CAD, Inc.10/19/2020 Page 3AutoSPRINK 2019 v15.1.20.0 11:19:51AM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Light Hazard (2) Job Number: 20-242 Sprinkler S101 21.58 20.19 5.6 14.848 Sprinkler S102 20.72 20.19 5.6 13.689 Sprinkler S105 20.31 20.19 5.6 13.149 Sprinkler S108 20.19 20.19 5.6 13.000 Sprinkler 674 23.18 20.19 5.6 17.138 Sprinkler 675 23.05 20.19 5.6 16.948 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.10/19/2020 Page 4AutoSPRINK 2019 v15.1.20.0 11:19:53AM Job Name: BYRNE DAIRY Remote Area Number: 2 Date: 10/19/2020 Node @ @ Supply Analysis Static (psi) Required Pressure (psi)(gpm) Total DemandAvailable (psi) Flow (gpm) Residual (psi)Name 54.0001 76.232229.031750.00 92.09493.000Water Supply Node Analysis NotesDischarge at Node (gpm) Pressure at Node (psi) Node TypeElevation (Foot)Node Number -5'-0 129.0376.232Supply1 27'-6½21.5814.848SprinklerS101 27'-6½20.7213.689SprinklerS102 27'-6½20.3113.149SprinklerS105 27'-6½20.1913.000SprinklerS108 27'-6½23.1817.138Sprinkler674 27'-6½23.0516.948Sprinkler675 -5'-0 76.2302 2'-6 72.82018 2'-6 72.70319 21'-4½29.12528 27'-6½17.97929 12'-6½60.62632 11'-5 66.31133 12'-6½65.82134 © M.E.P.CAD, Inc.10/19/2020 Page 5AutoSPRINK 2019 v15.1.20.0 11:19:57AM Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 2 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-FactorElev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 27'-6½8'-0 0.149 27'-6½8'-0S108 S105 1½• • • • • Route 1 • • • • •(See Notes) 1.6820 13.00020.19 0.018617 Sprinkler 20.19 5.6 100 27'-6½8'-0 0.540 27'-6½8'-0S105 S102 1½(See Notes) 1.6820 13.14920.31 0.067470 Sprinkler 40.50 5.6 100 27'-6½8'-0 1.159 27'-6½8'-0S102 S101 1½(See Notes) 1.6820 13.68920.72 0.144901 Sprinkler 61.22 5.6 100 7'-0½ 27'-6½12'-4½3.131 27'-6½5'-3½S101 29 1½(See Notes) 1.6820 14.84821.58 0.253322 Sprinkler, 82.79 5.6 T(7'-0½) 100 5'-8½ 21'-4½11'-10½ 2.680 8.466 27'-6½6'-229 28 1½(See Notes) 1.6100 17.97946.24 0.712336 Flow (q) from Route 2 129.03 PO(5'-8½) 100 14'-6½ 12'-6½48'-0½ 3.837 27.665 21'-4½33'-628 32 1½(See Notes) 1.6820 29.12549.11 0.575645 Flow (q) from Route 2 129.03 2E(3'-6½), fT(7'-6) 100 7'-5½ 12'-6½30'-3½5.194 12'-6½22'-1032 34 2 (See Notes) 2.1570 60.626 0.171426129.03 fT(7'-5½) 100 11'-5 1'-1½ 0.483 0.007 12'-6½1'-1½34 33 4 4.2600 65.82179.65 0.006233 Flow (q) from Route 3 129.03 100 55'-3½ 2'-6 67'-6½ 3.860 2.532 11'-5 12'-2½33 19 4 (See Notes) 4.2600 66.311 0.004449129.03 DPV(13'-2), BV(15'-9½), PO(2 6'-4), BFP(-2.231), B.O.R. 120 26'-4 2'-6 26'-4 0.117 2'-6 0'-019 18 4 (See Notes) 4.2600 72.703 0.004449129.03 T(26'-4) 120 91'-5 -5'-0 303'-5½ 3.257 0.153 2'-6 212'-0½18 2 6 (See Notes) 6.2800 72.820 0.000505129.03 2E(22'-1), T(47'-3½) 140 © M.E.P.CAD, Inc.10/19/2020 Page 6AutoSPRINK 2019 v15.1.20.0 11:20:01AM2 Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 2 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-FactorElev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit -5'-0 115'-7 0.002 -5'-0 115'-72 1 12 (See Notes) 12.4600 76.230 0.000018129.03 Water Supply 140 1 100.00 Hose Allowance At Source 229.03 Route 1Total(Pt) 76.232 27'-6½8'-0 0.190 27'-6½8'-0675 674 1½• • • • • Route 2 • • • • •(See Notes) 1.6820 16.94823.05 0.023793 Sprinkler 23.05 5.6 100 7'-0½ 27'-6½9'-9 0.841 27'-6½2'-8½674 29 1½(See Notes) 1.6820 17.13823.18 0.086217 Sprinkler, 46.24 5.6 T(7'-0½) 100 17.979 Total(Pt)Route 2 © M.E.P.CAD, Inc.10/19/2020 Page 7AutoSPRINK 2019 v15.1.20.0 11:20:01AM2 Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 2 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90°cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90°Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 4.87 )(150 1.33 140 1.16 130 0.713 100Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.10/19/2020 Page 8AutoSPRINK 2019 v15.1.20.0 11:20:00AM2 Hydraulic Calculations Location: 323 ELMIRA ROAD, ITHACA, NY 14850, Project Name: BYRNE DAIRY Drawing Name: BYRNE DAIRY FP Calculation Date: 10/19/2020 for Design Remote Area Location: Light Hazard Area of Application: 1500ft² (Actual 1007ft²) Coverage per Sprinkler: 130ft² Type of sprinklers calculated: 8 ATTIC (ROOF SPAN) 3Remote Area Number: Occupancy Classification: No. of sprinklers calculated: Density 0.10gpm/ft² Upright No. of nozzles calculated:0 In-rack Demand: Hose Streams:at Node:Type:Allowance at Source N/Aat Node:N/A gpm 1100.00 (including Hose Streams where applicable):Total Water Required 74.739@311.56From Water Supply at Node 1:(Safety Margin = 16.660 psi) Type of System: Volume of Dry or PreAction System:80.60gal Source:ITHACA FIRE DEPARTMENT Location: Date:for Node:1 Name of Contractor: ITHACA FIRE DEPARTMENTAuthority Having Jurisdiction: Address: Phone Number: Name of designer: , Nolan Alley Notes: 10/19/2020© M.E.P.CAD, Inc.Page 1AutoSPRINK 2019 v15.1.20.0 11:20:07AM3 Hydraulic Graph Water Supply Node: 1 Job Name: BYRNE DAIRY Remote Area Number: 3 Date: 10/19/2020 Summary Sheet N 1.85 © M.E.P.CAD, Inc.10/19/2020 Page 2AutoSPRINK 2019 v15.1.20.0 11:20:09AM Hydraulic Graph B.O.R. Job Name: BYRNE DAIRY Remote Area Number: 3 Date: 10/19/2020 Summary Sheet N 1.85 © M.E.P.CAD, Inc.10/19/2020 Page 3AutoSPRINK 2019 v15.1.20.0 11:20:09AM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Light Hazard (3) Job Number: 20-242 Sprinkler S101 21.58 20.19 5.6 14.848 Sprinkler S102 20.72 20.19 5.6 13.689 Sprinkler S103 24.62 23.09 5.6 19.332 Sprinkler S104 40.48 20.19 5.6 52.263 Sprinkler S105 20.31 20.19 5.6 13.149 Sprinkler S106 39.17 20.19 5.6 48.920 Sprinkler S107 24.49 23.09 5.6 19.119 Sprinkler S108 20.19 20.19 5.6 13.000 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.10/19/2020 Page 4AutoSPRINK 2019 v15.1.20.0 11:20:11AM Job Name: BYRNE DAIRY Remote Area Number: 3 Date: 10/19/2020 Node @ @ Supply Analysis Static (psi) Required Pressure (psi)(gpm) Total DemandAvailable (psi) Flow (gpm) Residual (psi)Name 54.0001 74.739311.561750.00 91.39993.000Water Supply Node Analysis NotesDischarge at Node (gpm) Pressure at Node (psi) Node TypeElevation (Foot)Node Number -5'-0 211.5674.739Supply1 27'-6½21.5814.848SprinklerS101 27'-6½20.7213.689SprinklerS102 22'-3 24.6219.332SprinklerS103 12'-6½40.4852.263SprinklerS104 27'-6½20.3113.149SprinklerS105 12'-6½39.1748.920SprinklerS106 22'-3 24.4919.119SprinklerS107 27'-6½20.1913.000SprinklerS108 -5'-0 74.7332 2'-6 71.09418 2'-6 70.80119 21'-4½23.02326 22'-3 21.87227 21'-4½24.38428 27'-6½17.97929 12'-6½56.13330 12'-6½56.15231 12'-6½57.03532 © M.E.P.CAD, Inc.10/19/2020 Page 5AutoSPRINK 2019 v15.1.20.0 11:20:15AM Job Name: BYRNE DAIRY Remote Area Number: 3 Date: 10/19/2020 NotesDischarge at Node (gpm) Pressure at Node (psi) Node TypeElevation (Foot)Node Number 11'-5 62.94633 12'-6½62.44634 © M.E.P.CAD, Inc.10/19/2020 Page 6AutoSPRINK 2019 v15.1.20.0 11:20:15AM Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 3 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-FactorElev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 27'-6½8'-0 0.149 27'-6½8'-0S108 S105 1½• • • • • Route 1 • • • • •(See Notes) 1.6820 13.00020.19 0.018617 Sprinkler 20.19 5.6 100 27'-6½8'-0 0.540 27'-6½8'-0S105 S102 1½(See Notes) 1.6820 13.14920.31 0.067470 Sprinkler 40.50 5.6 100 27'-6½8'-0 1.159 27'-6½8'-0S102 S101 1½(See Notes) 1.6820 13.68920.72 0.144901 Sprinkler 61.22 5.6 100 7'-0½ 27'-6½12'-4½3.131 27'-6½5'-3½S101 29 1½(See Notes) 1.6820 14.84821.58 0.253322 Sprinkler, 82.79 5.6 T(7'-0½) 100 5'-8½ 21'-4½11'-10½ 2.680 3.726 27'-6½6'-229 28 1½(See Notes) 1.6100 17.979 0.31347682.79 PO(5'-8½) 100 14'-6½ 12'-6½48'-0½ 3.837 28.814 21'-4½33'-628 32 1½(See Notes) 1.6820 24.38449.11 0.599566 Flow (q) from Route 2 131.90 2E(3'-6½), fT(7'-6) 100 7'-5½ 12'-6½30'-3½5.410 12'-6½22'-1032 34 2 (See Notes) 2.1570 57.035 0.178550131.90 fT(7'-5½) 100 11'-5 1'-1½ 0.483 0.017 12'-6½1'-1½34 33 4 4.2600 62.44679.65 0.015558 Flow (q) from Route 3 211.56 100 55'-3½ 2'-6 67'-6½ 3.860 3.995 11'-5 12'-2½33 19 4 (See Notes) 4.2600 62.946 0.011104211.56 DPV(13'-2), BV(15'-9½), PO(2 6'-4), BFP(-3.245), B.O.R. 120 26'-4 2'-6 26'-4 0.292 2'-6 0'-019 18 4 (See Notes) 4.2600 70.801 0.011104211.56 T(26'-4) 120 91'-5 -5'-0 303'-5½ 3.257 0.383 2'-6 212'-0½18 2 6 (See Notes) 6.2800 71.094 0.001261211.56 2E(22'-1), T(47'-3½) 140 © M.E.P.CAD, Inc.10/19/2020 Page 7AutoSPRINK 2019 v15.1.20.0 11:20:18AM3 Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 3 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-FactorElev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit -5'-0 115'-7 0.005 -5'-0 115'-72 1 12 (See Notes) 12.4600 74.733 0.000045211.56 Water Supply 140 1 100.00 Hose Allowance At Source 311.56 Route 1Total(Pt) 74.739 22'-3 8'-0 0.213 22'-3 8'-0S107 S103 1½• • • • • Route 2 • • • • •(See Notes) 1.6820 19.11924.49 0.026599 Sprinkler 24.49 5.6 100 7'-0½ 22'-3 26'-4½2.541 22'-3 19'-3½S103 27 1½(See Notes) 1.6820 19.33224.62 0.096383 Sprinkler, 49.11 5.6 T(7'-0½) 100 5'-8½ 21'-4½6'-6½ 0.369 0.782 22'-3 0'-1027 26 1½(See Notes) 1.6100 21.872 0.11926949.11 PO(5'-8½) 100 21'-4½14'-1½1.362 21'-4½14'-1½26 28 1½ 1.6820 23.023 0.09638349.11 100 24.384 Total(Pt)Route 2 7'-1½ 12'-6½11'-5 7.213 12'-6½4'-3½S106 30 1 • • • • • Route 3 • • • • •(See Notes) 1.0490 48.92039.17 0.632239 Sprinkler, 39.17 5.6 T(3'-7), PO(3'-7) 100 12'-6½1'-0 0.019 12'-6½1'-030 31 2 2.1570 56.133 0.01888939.17 100 10'-6½ 12'-6½89'-7½6.294 12'-6½79'-131 34 2 (See Notes) 2.1570 56.15240.48 0.070227 Flow (q) from Route 4 79.65 fE(3'-1), fT(7'-5½) 100 62.446 Total(Pt)Route 3 3'-7 12'-6½5'-9½3.889 12'-6½2'-2½S104 31 1 • • • • • Route 4 • • • • •(See Notes) 1.0490 52.26340.48 0.672108 Sprinkler, 40.48 5.6 PO(3'-7) 100 56.152 Total(Pt)Route 4 © M.E.P.CAD, Inc.10/19/2020 Page 8AutoSPRINK 2019 v15.1.20.0 11:20:18AM3 Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 3 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90°cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90°Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 4.87 )(150 1.33 140 1.16 130 0.713 100Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.10/19/2020 Page 9AutoSPRINK 2019 v15.1.20.0 11:20:18AM3 Hydraulic Calculations Location: 323 ELMIRA ROAD, ITHACA, NY 14850, Project Name: BYRNE DAIRY Drawing Name: BYRNE DAIRY FP Calculation Date: 10/19/2020 for Design Remote Area Location: Light Hazard Area of Application: 1500ft² (Actual 349ft²) Coverage per Sprinkler: 130ft² Type of sprinklers calculated: 5 CANOPY 4Remote Area Number: Occupancy Classification: No. of sprinklers calculated: Density 0.10gpm/ft² Pendent No. of nozzles calculated:0 In-rack Demand: Hose Streams:at Node:Type:Allowance at Source N/Aat Node:N/A gpm 1100.00 (including Hose Streams where applicable):Total Water Required 48.246@203.02From Water Supply at Node 1:(Safety Margin = 44.028 psi) Type of System: Volume of Dry or PreAction System:80.60gal Source:ITHACA FIRE DEPARTMENT Location: Date:for Node:1 Name of Contractor: ITHACA FIRE DEPARTMENTAuthority Having Jurisdiction: Address: Phone Number: Name of designer: , Nolan Alley Notes: 10/19/2020© M.E.P.CAD, Inc.Page 1AutoSPRINK 2019 v15.1.20.0 11:20:41AM4 Hydraulic Graph Water Supply Node: 1 Job Name: BYRNE DAIRY Remote Area Number: 4 Date: 10/19/2020 Summary Sheet N 1.85 © M.E.P.CAD, Inc.10/19/2020 Page 2AutoSPRINK 2019 v15.1.20.0 11:20:44AM Hydraulic Graph B.O.R. Job Name: BYRNE DAIRY Remote Area Number: 4 Date: 10/19/2020 Summary Sheet N 1.85 © M.E.P.CAD, Inc.10/19/2020 Page 3AutoSPRINK 2019 v15.1.20.0 11:20:44AM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Light Hazard (4) Job Number: 20-242 Sprinkler S301 25.07 14.82 5.6 20.047 Sprinkler S302 20.52 14.82 5.6 13.426 Sprinkler S303 15.99 14.82 5.6 8.152 Sprinkler S304 14.82 14.82 5.6 7.000 Sprinkler S305 26.62 14.82 5.6 22.604 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.10/19/2020 Page 4AutoSPRINK 2019 v15.1.20.0 11:20:46AM Job Name: BYRNE DAIRY Remote Area Number: 4 Date: 10/19/2020 Node @ @ Supply Analysis Static (psi) Required Pressure (psi)(gpm) Total DemandAvailable (psi) Flow (gpm) Residual (psi)Name 54.0001 48.246203.021750.00 92.27593.000Water Supply Node Analysis NotesDischarge at Node (gpm) Pressure at Node (psi) Node TypeElevation (Foot)Node Number -5'-0 103.0248.246Supply1 10'-5 25.0720.047SprinklerS301 10'-5 20.5213.426SprinklerS302 10'-5 15.998.152SprinklerS303 10'-5 14.827.000SprinklerS304 10'-5 26.6222.604SprinklerS305 -5'-0 48.2452 2'-6 44.88718 2'-6 44.81019 12'-6½23.80120 12'-6½23.80921 12'-6½22.78322 12'-6½13.59523 12'-6½24.72024 12'-6½7.91925 11'-5 38.73033 12'-6½38.24234 © M.E.P.CAD, Inc.10/19/2020 Page 5AutoSPRINK 2019 v15.1.20.0 11:20:50AM Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 4 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-FactorElev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 1'-5 12'-6½17'-6½ -0.917 1.836 10'-5 16'-1½S304 25 1 • • • • • Route 1 • • • • •(See Notes) 1.0490 7.00014.82 0.104671 Sprinkler, 14.82 5.6 E(1'-5) 100 12'-6½14'-0 5.676 12'-6½14'-025 23 1 1.0490 7.91915.99 0.405419 Flow (q) from Route 2 30.80 100 3'-7 12'-6½9'-9½10.214 12'-6½6'-323 21 1 (See Notes) 1.0490 13.59520.52 1.042446 Flow (q) from Route 3 51.32 PO(3'-7) 100 12'-6½14'-0 0.910 12'-6½14'-021 24 2 2.1570 23.80925.07 0.065010 Flow (q) from Route 4 76.40 100 10'-6½ 12'-6½119'-7½ -0.000 13.522 12'-6½109'-124 34 2 (See Notes) 2.1570 24.72026.62 0.113033 Flow (q) from Route 5 103.02 fE(3'-1), fT(7'-5½) 100 11'-5 1'-1½ 0.483 0.005 12'-6½1'-1½34 33 4 4.2600 38.242 0.004110103.02 100 55'-3½ 2'-6 67'-6½ 3.860 2.220 11'-5 12'-2½33 19 4 (See Notes) 4.2600 38.730 0.002933103.02 DPV(13'-2), BV(15'-9½), PO(2 6'-4), BFP(-2.022), B.O.R. 120 26'-4 2'-6 26'-4 0.077 2'-6 0'-019 18 4 (See Notes) 4.2600 44.810 0.002933103.02 T(26'-4) 120 91'-5 -5'-0 303'-5½ 3.257 0.101 2'-6 212'-0½18 2 6 (See Notes) 6.2800 44.887 0.000333103.02 2E(22'-1), T(47'-3½) 140 -5'-0 115'-7 0.001 -5'-0 115'-72 1 12 (See Notes) 12.4600 48.245 0.000012103.02 Water Supply 140 1 100.00 Hose Allowance At Source 203.02 Route 1Total(Pt) 48.246 © M.E.P.CAD, Inc.10/19/2020 Page 6AutoSPRINK 2019 v15.1.20.0 11:20:53AM4 Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 4 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-FactorElev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 3'-7 12'-6½5'-8 -0.917 0.684 10'-5 2'-1½S303 25 1 • • • • • Route 2 • • • • •(See Notes) 1.0490 8.15215.99 0.120506 Sprinkler, 15.99 5.6 T(3'-7) 100 7.919 Total(Pt)Route 2 3'-7 12'-6½5'-8 -0.917 1.086 10'-5 2'-1½S302 23 1 • • • • • Route 3 • • • • •(See Notes) 1.0490 13.42620.52 0.191187 Sprinkler, 20.52 5.6 T(3'-7) 100 13.595 Total(Pt)Route 3 10'-0 12'-6½16'-10½ -0.917 4.671 10'-5 6'-10½S301 20 1 • • • • • Route 4 • • • • •(See Notes) 1.0490 20.04725.07 0.277013 Sprinkler, 25.07 5.6 2E(1'-5), T(3'-7), PO(3'-7) 100 12'-6½1'-0 0.008 12'-6½1'-020 21 2 2.1570 23.801 0.00827625.07 100 23.809 Total(Pt)Route 4 1'-5 12'-6½3'-6½ -0.917 1.096 10'-5 2'-1½S305 22 1 • • • • • Route 5 • • • • •(See Notes) 1.0490 22.60426.62 0.309546 Sprinkler, 26.62 5.6 E(1'-5) 100 5'-0 12'-6½8'-9 1.937 12'-6½3'-922 24 1 (See Notes) 1.0490 22.783 0.22092326.62 PO(5'-0) 120 24.720 Total(Pt)Route 5 © M.E.P.CAD, Inc.10/19/2020 Page 7AutoSPRINK 2019 v15.1.20.0 11:20:53AM4 Date: 10/19/2020 Job Name: BYRNE DAIRY Remote Area Number: 4 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90°cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90°Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 4.87 )(150 1.33 140 1.16 130 0.713 100Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.10/19/2020 Page 8AutoSPRINK 2019 v15.1.20.0 11:20:52AM4