Loading...
HomeMy WebLinkAboutCornell Kennedy-Clark Hall Thermal Drawings Conformed Set FileView(2)KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE ISSUED AS CONFORMED DOCUMENTS NOVEMBER 09, 2020 MECHANICAL ITHACA, NEW YORK CORNELL UNIVERSITY III Winners Circle. PO Box 5269 Albany, NY 12205-0269 www.chacompanies.comMain: (518) 453-4500 www.chacompanies.comLLENROCARZEYB D EDNUOFCORN E L L U N I VE R S I T YSTRUCTURAL CIVIL MECHANICAL S S ELECTRICAL Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624AUG. 2020 1" = 20'-0" BGBG/AB AB C-100 SITE PLAN EXISTING CONDITIONS SHEET 1 OF 2 ITHACA, NEW YORK CORNELL UNIVERSITY ƒ ƒ6'6'#10 VALVE NOT VISABLE Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624AUG. 2020 1" = 20'-0" BGBG/AB AB C-101 SITE PLAN EXISTING CONDITIONS SHEET 2 OF 2 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624AUG. 2020 1" = 30'-0" BGBG/AB AB C-110 SEQUENCING PLAN PHASE 1 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624AUG. 2020 1" = 30'-0" BGBG/AB AB C-111 SEQUENCING PLAN PHASE 2 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624AUG. 2020 1" = 30'-0" BGBG/AB AB C-112 SEQUENCING PLAN PHASE 3A ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624AUG. 2020 1" = 30'-0" BGBG/AB AB C-113 SEQUENCING PLAN PHASE 3B ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624MAR. 2020 1" = 20'-0" BGBG/AB AB C-210 SITE PLAN NEW PIPING SHEET 1 OF 2 ITHACA, NEW YORK CORNELL UNIVERSITY ƒ ƒ6'6'#10 VALVE NOT VISABLE Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624MAR. 2020 1" = 20'-0" BGBG/AB AB C-211 SITE PLAN NEW PIPING SHEET 2 OF 2 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624MAR. 2020 1" = 20'-0" BGBG/AB AB C-220 PLAN AND PROFILE NEW STEAM PIPING ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019Designed By:Checked By:Drawing No.:Issue Date:Designed By:Drawn By:Project No:Scale:No.ByDateSubmittal / RevisionCORNELL UNIVERSITYITHACA, NEW YORKKENNEDY HALL TO CLARKHALL THERMAL SYSTEMUPGRADEApp'd.www.chacompanies.com300 South State Street - Suite 600315.471.3920Syracuse, NY 1320260624AUG. 2020AS NOTEDBGBG/ABABC-230PROFILENEW HOT WATER PIPINGSHEET 1ITHACA, NEW YORKCORNELL UNIVERSITY Drawing Copyright © 2019Designed By:Checked By:Drawing No.:Issue Date:Designed By:Drawn By:Project No:Scale:No.ByDateSubmittal / RevisionCORNELL UNIVERSITYITHACA, NEW YORKKENNEDY HALL TO CLARKHALL THERMAL SYSTEMUPGRADEApp'd.www.chacompanies.com300 South State Street - Suite 600315.471.3920Syracuse, NY 1320260624AUG. 2020AS NOTEDBGBG/ABABC-231PROFILENEW HOT WATER PIPINGSHEET 2ITHACA, NEW YORKCORNELL UNIVERSITY Drawing Copyright © 2019Designed By:Checked By:Drawing No.:Issue Date:Designed By:Drawn By:Project No:Scale:No.ByDateSubmittal / RevisionCORNELL UNIVERSITYITHACA, NEW YORKKENNEDY HALL TO CLARKHALL THERMAL SYSTEMUPGRADEApp'd.www.chacompanies.com300 South State Street - Suite 600315.471.3920Syracuse, NY 1320260624AUG. 2020AS NOTEDBGBG/ABABC-232PROFILENEW HOT WATER PIPINGSHEET 3ITHACA, NEW YORKCORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624AUG. 2020 AS NOTED BGBG/AB AB C-240 PROFILE NEW CHILLED WATER PIPING ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624AUG. 2020 AS NOTED BGBG/AB AB C-250 PROFILE NEW POTABLE WATER PIPING ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624SEP. 2020 1" = 30'-0" BGBG/AB AB C-260 SITE PLAN CAMERA CONDUIT ROUTING ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624SEP. 2020 NONE BGBG/AB AB C-261 CAMERA CONDUIT ROUTING DETAILS ITHACA, NEW YORK CORNELL UNIVERSITY ROADWAYS-REPLACE TO LAWNS-COMPACTED IN 12" LAYERS ROADWAYS-COMPACTED IN 6" LAYERS SAND ENCASEMENT-COMPACTED UNDISTURBED SOIL 1 1/2"Ø SCH 80 PVC DUCTS MATCH EXISTING CONDITIONS FINISHED GRADE TOPSOIL MIX- 4" MINIMUM COMPACTED DEPTH TRACEABLE ELECTRIC WARNING TAPE 6" BELOW GRADE GENERAL FILL-EXCAVATED SOILS 12"NON-ROADWAYS 18" MIN.ROADWAYS 24" MIN.2"6" COVER6" BED1/8" 3/4"1/2"1/2" 2. JOINTSEALANT TYPICAL SCORE LINE PREMOLDED BITUMINOUSJOINT FILLER EXPANSION JOINT SCORE JOINTNOTE:1.PROVIDE SCORE LINES AT APPROX. SQUARE PATTERN NOT MORETHAN 5FT c/c AND TO MATCH EXISTING. PROVIDE EXPANSION JOINTS EVERY 20'-0" OR EVERY 400 SQ. FT. IN ROCK IN EARTH MIN. 18" COMMON FILL 6"MIN. 4"12"PAVEMENT, SEE DETAIL. HEAVY DUTY BITUMINOUS GRANULAR FILL PIPE BEDDING AS PER SPECIFICATION TOPSOIL MIX-6" MINIMUM RESEED LAWN AREAS COMPACTED EARTH AS PER DETAIL.+ 2'-0"12"GRADE ROADWAYS 24" MIN.NON-ROADWAYS 18" MIN.PIPE O.D. UTILITY WARNING TAPE WITH TRACER WIRE.6"WITH FILTER FABRIC SOCK SEE DETAIL PAVEMENT CONCRETE BITUMINOUS "CRUSHER-RUN" COMPACTED PLAN ELEVATION DRY BED OF CONCRETE MIX 1 1/2 CU. FT. "LEAN" CONCRETE REPAIR TO MATCH EXISTING DRY CONCRETE MIX AS BED TYPE 2 SUB BASE AGGREGATE AGGREGATE BASE PAVEMENT SEE DETAIL BITUMINOUS CONCRETE 5"x16"x5'MIN., SAWN TOP, SPLIT FACE REPAIR BACK OF CURB TO MATCH UNDER DRAIN TUBING MIX AS CURB BEDDING 3" MIN. DEPTH "DRY" CONCRETE FOR ENTIRE LENGTH 1 1/2 CU. FT. "LEAN" CONCRETE EXISTING OR AS SPECIFIED TYPE "A" GRANITE CURBING COMPACTED SUB-SOIL 6" NORMAL REVEAL, 1"AT DRIVEWAY & 2" AT SIDEWALK DROP TRANSITIONS AT 150' INTERVALS FOR EXPANSION MORTAR ALL OTHER JOINTS 12"4"UNDERDRAIN FILTER 12" USE FLEXIBLE CAULK CONCRETE PAVEMENT NEW BITUMINOUS NEW BASE OVERLAY DEEP 18" x 3" EXISTING PAVEMENT SAWCUT EXISTING BASE TACK COAT (SEE BITUMINOUS CONCRETE OVERLAY DETAIL) COMPACTED SUBGRADE COMPACTED SUBGRADE CONCRETE PAVEMENT NEW HEAVY DUTY ROADWAY FORM OR SAWCUT GROOVE APPLY TRACK COAT ON ALL SURFACES5/8"1/2" HOT POURED RUBBERIZED ASPHALT (TO BE APPROVED BY ENGINEER)4" MIN.LAWN SEED OR HYDROSEED-AS SPECIFIED MULCH-STALKS FROM OATS, WHEAT AND/OR RYE FREE FROM SEED AND WEED SEED EXISTING LAWN TOPSOIL MIX AS SPECIFIED - 4" AFTER COMPACTION UNDISTURBED AND/OR COMPACTED EARTH BACK FILL AS SPECIFIED - 2/3 EXISTING SOIL MIXED WITH 1/3 NEW ORGANIC MATERIAL NOTE: FERTILIZER ADDED AS RECOMMENDED BY MANUFACTURER LAWN AREA-SEEDING DETAIL 1 1/2" DIRECT BURIED CONDUIT DETAIL TYPICAL STEAM TUNNEL CROSS SECTION MARKING TAPEFINISHED GRADE 3" MORTAR CANT BITUTHENE MEMBRANE CLEAN & PAINT BASE SLAB WITH LATEX BONDING COMPOUND ON BASE SLAB. PRECAST TUNNEL WITH RECESSED LIFTING HOOKS CAST-IN PLACE CONCRETE SLAB 10 MIL POLY BELOW SLAB. TRIM AT EDGE OF FORM FILTER FABRIC 6" SDR-35 UNDERDRAIN PIPE W/#2 STONE ENVELOPE AROUND (MIN. 3") VARIES8"CUT POLY AND PLACE STONE AGAINST POLY DRAINAGE STONE (MIX OF #1 & #2 STONE, MIN. 6" THICK) WRAP FILTER FABRIC AROUND STONE TO TOP OF BASE SLAB BACKFILL AROUND TUNNEL WITH SAND STEAM PIPE 2" SAND PIPE BEDDING MATERIAL ~TYPICAL SECTION AT PRECAST TUNNEL TO TUNNEL CONNECTION (3) STRIPS OF BUTYL TAPE SEALANT (MINIMUM 3/4" x 3/4" SQUARE)3/8" MIN. TUNNEL BASE SLAB EXPANSION JOINT DETAIL 2'-0" WATER STOP PROVIDE AT 100' MAX. SPACING 2'-0"8"4"1/2" SONNEBORN SONOFLEX F JOINT FILLER WITH SONNEBORN SONOLASTIC NP2 SEALANT TYPICAL LIFTING ANCHOR DETAIL RECESSED LIFTING ANCHOR "SWIFT LIFT P-52 SL" (BY DAYTON SUPERIOR) OR APPROVED EQUIVALENT. LOCATION, EMBEDMENT, QUANTITY AND SIZE OF VAULT ROOF ANCHORS TO BE DETERMINED BY PRE-CAST CONTRACTOR. 6" DIA X 3" DP RECESS. COVER WITH LOOSE GRAVEL AND COVER WITH A THIN LAYER OF MORTOR. FOR MANHOLE ROOF LIFTING ANCHORS ONLY COVER WITH 12" SQ. BITUTHENE TYPICAL PIPE TRENCH SECTION PRECAST TUNNEL SECTIONS BUTYL TAPE USE PROTECTION BOARD FOR BITUTHENE 3000 FROM DAMAGE BEFORE BACKFILL FILL SPACE WITH CLOSED CELL FOAM SEALANT TRIMMED FLUSH WITH TUNNEL Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BGBG/AB AB C-500 CIVIL DETAILS SHEET 1 ITHACA, NEW YORK CORNELL UNIVERSITY BITUTHENE MEMBRANE DETAIL NO. 1.1.1 DETAIL NO. 2.1.9 DETAIL NO. 4.6.6 DETAIL NO. 1.3.2 GRANITE CURB DETAIL MEDIUM DUTY BITUMINOUS CONCRETE PAVEMENT DETAIL DETAIL NO. 1.4.1 HEAVY DUTY BITUMINOUS CONCRETE PAVEMENT DETAIL DETAIL NO. 1.4.2 BITUMINOUS CONCRETE - JOINING NEW TO EXISTING DETAIL DETAIL NO. 1.4.4 DETAIL NO. 4.3.3 WALL TUNNEL ROOF (2) STRIPS OF BUTYL TAPE SEALANT (MIN 3/4" SQ) FOR LAST SECTION OF TUNNEL INFILL PLACED, BUTYL TAPE SEALANT DOES NOT NEED TO BE INSTALLED. FOR THE FINAL TUNNEL SECTION INSTALLED, PROVIDE FORMED FOAM SEALANT AT JOINT BETWEEN TUNNEL SECTIONS AND COVER WITH BITUTHENE. NOTE OR WALL TAPERED FORMED FOAM SEALANT CANT (3 SIDES) BITUTHENE MEMBRANE 12"TYP.BITUTHENE MEMBRANE SECTION WITH FLUSH ENDS FROM SAW CUTTING TYPICAL SECTION AT TUNNEL TO WALL CONNECTION BITUMINOUS CONCRETE PAVEMENT JOINING CONCRETE PAVEMENT DETAIL DETAIL NO. 1.4.5 BIG RED BARN, MALOTT HALL AND SPACE SCIENCES PARKING LOTS GARDEN AVE, SCIENCES DRIVE AND CLARK EAST PARKING LOT ADDITIONAL NOTES: 1.0 CONCRETE WIDTH TO MATCH EXISTING. 2.0 SEE SPECIFICATION 033000 FOR ADDITIONAL INFORMATION. 3.0 USE FOGGING SPRAY CURING METHOD. 4.0 USE SAWCUTTING METHOD FOR JOINING PANELS. 5.0 USE 100% SILANE PENETRATION SEALER. 1/8"3/4"1/2"1/2" 2. JOINT SEALANT TYPICAL SCORE LINE PREMOLDED BITUMINOUS JOINT FILLER EXPANSION JOINT SCORE JOINT NOTE: 1. PROVIDE SCORE LINES AT APPROX. SQUARE PATTERN NOT MORE THAN 5FT c/c AND TO MATCH EXISTING. PROVIDE EXPANSION JOINTS EVERY 20'-0" OR EVERY 400 SQ. FT. Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BGBG/AB AB C-501 CIVIL DETAILS SHEET 2 ITHACA, NEW YORK CORNELL UNIVERSITY 2" CHILLED WATER ANCHOR BLOCK DETAILS PROTECTIVE WOOD CONSTRUCTION FENCING FOR TREES, SHRUBS, ROOTS AND SOIL DETAIL DETAIL NO. 1.8.11 ADA ACCESSIBLE STANDARD PARKING SPACES DETAIL DETAIL NO. 7.1.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY FOR N.Y. STATE DETAIL DETAIL NO. 7.1.5 WALKS - PORTLAND CEMENT CONCRETE DETAIL NO. 1.5.4 FOAMGLASS WALL PENETRATION DETAIL CONCRETE WALK JOINTS DETAIL NO. 1.5.6 CHILLED WATER TRENCH CROSS-SECTION DETAIL NO. 4.1.1 0.7 0.5 1.43"2.1 1.2 SOILS, MULTIPLY BY THE FOLLOWING OR LARGER FACTORS AS NECESSARY TO SOFT CLAY = 4.0 SAND = 2.0 SAND & GRAVEL = 1.33 PREVENT MOVEMENT UNDER TEST PRESSURE: 2.0 1.2 3.5 8.2 5.7 4.9 3.4 2.1 1.0 0.6 4.3 17.2 12.1 7.4 2.1 3. NOTES: 1. 2. 6"6.3 12" 10" 8"10.9 25.4 17.8 4"3.1 3.6 6.3 2.0 FOR SOIL EQUIVALENT TO SAND AND GRAVEL CEMENTED WITH CLAY. FOR OTHER BEARING AREAS BASED ON 225 PSIG PRESSURE AND SOIL RESISTANCE OF 2,000 PSF THRUST BLOCK CONCRETE TO BE POURED AGAINST FIRM EARTH. PROVIDE CLEARANCE FOR BOLT REMOVAL. 14.6 10.2 1/4 O.D.HEIGHTDEPTH30° HEIGHT NOT TO EXCEED 1/2 DEPTH. NOTE- MAX. 30° HYDRANT, VALVE, (TYP.) MAX. WIDTH PLAN OF BEND SECTION OF BEND MIN. BEARING AREA (SQ. FT.) THRUST BLOCK SIZE SCHEDULE 22.5° BEND 11.25° BEND TEE, PLUG, CAP90° BEND 45° BENDPIPE SIZE GRADE PAVEMENT SHOWN FOR CONCRETE GRAVEL OR CRUSHED STONE TO SUPPORT VALVE BOX. OR BITUMINOUS PAVEMENT FINISHED GRADE SHOWN FOR EARTH, GRAVEL, VALVE BOX 5 1/4" DIA - 3 PIECE (BIBBY STE-CROIX) - SCREW STYLE #6 BASE ADAPTER BY ADAPTER INC. 1/2" BELOW GRADE RESILIENT WEDGE GATE VALVE SET BYBASE PLATE ADAPTORINSTALL MUD PLUG UNDER CAP INFRACT TY-6850 5 1/4" OR EQUIVALENT OVER 6 FT DEPTH CONTACT UTILITIES FOR EXTENDED OPERATOR RECOMMENDATIONS UNDUSTURBED OR COMPACTED NATIVE SOIL NOTE: 1.FOR THRUST BLOCK SEE DETAIL THIS SHT 2.SUITABLE FOR BOTH POTABLE AND CHILLED WATER APPLICATIONS Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BGBG/AB AB C-502 CIVIL DETAILS SHEET 3 ITHACA, NEW YORK CORNELL UNIVERSITY WATER PIPE THRUST BLOCK DETAILS DETAIL 4.5.3 VALVE AND BOX DETAIL DETAIL 4.5.4 TYPICAL WATER REWORK DETAIL 4.5.5 FSFSFSFSFSFSFSFSFSDrawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624AUG. 2020 1" = 20'-0" ER-001 SOIL EROSION AND SEDIMENT CONTROL PLAN-1 SCALE: 1"=20'-0" 0 80 FEET206040 ITHACA, NEW YORK CORNELL UNIVERSITYE 847,700E 847,800E 847,900E 848,000E 848,100E 848,200N 892,700 N 892,600 N 892,500 N 892,400 FILTER SOCK (TYP). FILTER SOCK (TYP). INLET PROTECTION (TYP). FILTER SOCK (TYP). PKPK/TE TE FSFS FSFSFSFSFS FS FSFSFSFS FSFS ƒ ƒ6'6'#10 VALVE NOT VISABLE 5/11/07 Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624AUG. 2020 1" = 20'-0" ER-002 SOIL EROSION AND SEDIEMENT CONTROL PLAN-2 SCALE: 1"=20'-0" 0 80 FEET206040 ITHACA, NEW YORK CORNELL UNIVERSITY N 892,300 N 892,200 N 892,100 N 892,000 INLET PROTECTION (TYP). FILTER SOCK (TYP). PKPK/TE TE Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 300 South State Street - Suite 600 315.471.3920 Syracuse, NY 13202 60624AUG. 2020 AS SHOWN PKPK/TE TE ERD-001 EROSION AND SEDIMENT CONTROL DETAILS ITHACA, NEW YORK CORNELL UNIVERSITY EROSION & SEDIMENT CONTROL NOTES Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624OCT. 2020 3/16"=1'-0" CBLKF AB E-301 CONDUIT LAYOUT CLARK HALL SUB-BASEMENT PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624OCT. 2020 AS NOTED BGKF AB E-311 ELECTRICAL ARRGT. SAVAGE HALL FOURTH FLOOR PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624OCT. 2020 3/16"=1'-0" BGKF AB E-312 ELECTRICAL ARRGT. KINZELBERG & SAVAGE HALL - BASEMENT PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624OCT. 2020 NONE BGKF AB E-320 ELECTRICAL ARRGT. BAILEY HALL BASEMENT MECH. ROOM PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624OCT. 2020 3/8"=1'-0" BGKF AB E-330 ELECTRICAL ARRGT. MALOTT HALL BASEMENT MECH. ROOM PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624DEC. 2020 3/8"=1'-0" BGBG/AB AB E-340 ELECTRICAL ARRGT. SPACE SCIENCES BASEMENT PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 NONE BGBG/AB AB M-101 STEAM SYSTEM SINGLE LINE ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 NONE BGBG/AB AB M-103 DISTRIBUTION HOT WATER SYSTEM SINGLE LINE ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624JUNE 2020 NONE CBLAB AB M-104 SAVAGE/KINZELBERG HOT WATER SYSTEM SINGLE LINE ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 3/16"=1'-0" BGBG/AB AB M-220 GENERAL ARRANGEMENT CLARK HALL SUB-BASEMENT PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019Designed By:Checked By:Drawing No.:Issue Date:Designed By:Drawn By:Project No:Scale:No.ByDateSubmittal / RevisionCORNELL UNIVERSITYITHACA, NEW YORKKENNEDY HALL TO CLARKHALL THERMAL SYSTEMUPGRADEApp'd.www.chacompanies.com441 South Salina Street Syracuse, NY 13202-4712Main: (315) 471-392060624MAR. 20203/8"=1'-0"BGBG/ABABM-221GENERAL ARRANGEMENTHOT WATER PIPINGCLARK HALLSUB-BASEMENT PLANITHACA, NEW YORKCORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 3/8"=1'-0" BGBG/AB AB M-222 GENERAL ARRANGEMENT NEW HOT WATER PIPING CLARK HALL TO NEWMAN TUNNEL ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624JUL. 2020 AS NOTED BGBG/AB AB M-223 GENERAL ARRANGEMENT NEW HOT WATER PIPING CLARK HALL TO NEWMAN TUNNEL SECTIONS AND DETAILS ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 3/8"=1'-0" BGBG/AB AB M-224 GENERAL ARRANGEMENT CLARK SERVICE TUNNEL AND NEWMAN TUNNEL PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 AS SHOWN BGBG/AB AB M-225 GENERAL ARRANGEMENT CLARK SERVICE TUNNEL AND NEWMAN TUNNEL SECTIONS ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019Designed By:Checked By:Drawing No.:Issue Date:Designed By:Drawn By:Project No:Scale:No.ByDateSubmittal / RevisionCORNELL UNIVERSITYITHACA, NEW YORKKENNEDY HALL TO CLARKHALL THERMAL SYSTEMUPGRADEApp'd.www.chacompanies.com441 South Salina Street Syracuse, NY 13202-4712Main: (315) 471-392060624MAR. 20203/8"=1'-0"BGBG/ABABM-226GENERAL ARRANGEMENTNORTH END OF NEWMANTUNNEL, NEWMAN LABAREAWAY ANDACCELERATOR BLDG.PLANITHACA, NEW YORKCORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624JUN. 2020 3/8"=1'-0" BGBG/AB AB M-230 GENERAL ARRANGEMENT SAVAGE HALL BASEMENT MECH. ROOM PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624JUN. 2020 AS NOTED BGBG/AB AB M-231 GENERAL ARRANGEMENT SAVAGE HALL 4TH FLR MECH. ROOMS PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BLBG/AB AB M-232 SAVAGE BASEMENT MECHANICAL ROOM PHOTOS SHT. 1 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BLBG/AB AB M-233 SAVAGE BASEMENT MECHANICAL ROOM PHOTOS SHT. 2 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BLBG/AB AB M-234 SAVAGE 4th FLOOR WEST PHOTOS SHT. 1 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BLBG/AB AB M-235 SAVAGE 4th FLOOR WEST PHOTOS SHT. 2 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BLBG/AB AB M-236 SAVAGE 4th FLOOR WEST PHOTOS SHT. 3 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BLBG/AB AB M-237 SAVAGE 4th FLOOR EAST PHOTOS SHT. 1 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BLBG/AB AB M-238 SAVAGE 4th FLOOR EAST PHOTOS SHT. 2 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 1/4"=1'-0" BGBG/AB AB M-240 GENERAL ARRANGEMENT KINZELBERG HALL BASEMENT & 4TH FLOOR MECH. ROOM PLANS ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BLBG/AB AB M-241 KINZELBURG 4th FLOOR MECHANICAL ROOM PHOTOS - SHT. 1 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BLBG/AB AB M-242 KINZELBURG 4th FLOOR MECHANICAL ROOM PHOTOS SHT. 2 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BLBG/AB AB M-243 KINZELBURG BASEMENT MECHANICAL ROOM PHOTOS - SHT. 1 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 NONE BGBG/AB AB M-250 GENERAL ARRANGEMENT BAILEY HALL BASEMENT MECH. ROOM PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BLBG/AB AB M-251 BAILEY HALL BASEMENT MECHANICAL ROOM - PHOTOS ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 1/4"=1'-0" BGBG/AB AB M-255 GENERAL ARRANGEMENT BAILEY HALL UNDER STAIRS PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 3/8"=1'-0" BGBG/AB AB M-260 GENERAL ARRANGEMENT ROBERTS HALL AREAWAY PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 3/8"=1'-0" BGBG/AB AB M-270 GENERAL ARRANGEMENT SPACE SCIENCES BASEMENT MECH. ROOM PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624JUNE. 2020 NONE BGBG/AB AB M-271 SPACE SCIENCES BASEMENT MECH. ROOM PHOTOS - SHT. 1 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624JUNE. 2020 BGBG/AB AB ITHACA, NEW YORK CORNELL UNIVERSITY NONE M-272 SPACE SCIENCES BASEMENT MECH. ROOM PHOTOS - SHT. 2 Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624JUNE 2020 BGBG/AB AB ITHACA, NEW YORK CORNELL UNIVERSITY NONE M-273 SPACE SCIENCES BASEMENT MECH. ROOM PHOTOS - SHT. 3 101 544 UP UP 190 1663 Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 3/8"=1'-0" BGBG/AB AB M-280 GENERAL ARRANGEMENT BIG RED BARN BASEMENT MECH. ROOM PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 3/8"=1'-0" BGBG/AB AB M-290 GENERAL ARRANGEMENT MALOTT HALL BASEMENT MECH. ROOM PLAN ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624MAR. 2020 NONE BGBG/AB AB M-291 MALOTT HALL BASEMENT MECH. ROOM PHOTOS - SHT. 1 ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624JUNE. 2020 BLBG/AB AB ITHACA, NEW YORK CORNELL UNIVERSITY NONE M-292 MALOTT HALL BASEMENT MECH. ROOM PHOTOS - SHT. 2 Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624JUNE 2020 BLBG/AB AB ITHACA, NEW YORK CORNELL UNIVERSITY NONE M-293 MALOTT HALL BASEMENT MECH. ROOM PHOTOS - SHT. 3 Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 3/8"=1'-0" BGBG/AB AB M-295 GENERAL ARRANGEMENT STEAM VAULTS "BAILEY", "28-5" AND "CW28-4" DEMOLITION PLANS ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 3/8"=1'-0" BGBG/AB AB M-296 GENERAL ARRANGEMENT STEAM VAULTS "29-2" AND "CL" DEMOLITION AND NEW WORK PLANS ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BGBG/AB AB M-500 EQUIPMENT SCHEDULES ITHACA, NEW YORK CORNELL UNIVERSITY 8.0 ALL NUTS SHALL BE ASTM 194 GRADE 2H. 9.0 ALL BOLTS SHALL BE ASTM 193 GRADE B7. OPEN DISC PRIOR TO TIGHTENING VALVE BOLTS. MATE BUTTERFLY VALVES TO PIPING WITH WELD NECK FLANGES. INSTALL VALVE WITH INSERT SIDE UPSTREAM. 1.0 NOTES: 3.0 4.0 5.0 6.0 7.02.0 HORIZONTAL CENTERLINE NEW STEAM RATED BUTTERFLY VALVE CAP (B) SCREWED CAP 45°SCREWEDINSULATION MAIN(B) HORIZONTAL CENTERLINE (A)6" TYPMAIN TO CLEARINSTALL ALL BUTTERFLY VALVES WITH THE DISC HORIZONTAL. IF DISC CAN NOT BE HORIZONTAL, THEN INSTALL ABOVE HORIZONTAL CENTERLINE AT 45° MAXIMUM. STEAM SLOPE UP BLOWDOWN LEG AND VENT STEAM MAIN SIZE (IN) NPS ≤ 8 NPS ≥ 10 SIZE (IN) VALVE (A) TYPE VENT SIZE (IN) 3/4 3/4 VALVE (B) TYPE BLOWDOWN BLOWDOWNVENT VERTICAL CENTERLINE BLOW-DOWN AND VENT PIPING (TAG A & B) SHALL BE 3/4" S.W. A53 OR A106 GR. B PIPE SCHEDULE 80 BLOWDOWN SHALL BE LOCATED ON THE HIGH SIDE OF THE VALVE IF THERE IS NO DRIP LEG. BLOWDOWN AND VENT VALVES SHALL BE OF 3-PIECE CONSTRUCTION. REFER TO THE CORNELL UNIVERSITY DESIGN AND CONSTRUCTION STANDARDS FOR INFORMATION ON VALVE MATERIALS AND ACCEPTABLE PRODUCTS. 3/4 3/4 (A) PITCH DOWN MAIN STEAM LINE TOWARDS TRAP WELDOLET OR REDUCING TEE w/CAP 8" MAX. OR 1 SIZE LESS THAN MAIN TO EXIST'G CONDENSATE RETURN UNITS 5. 6. 4. DIRT LEG AND TRAP DETAIL NOTES 1. 2. 3. JAMESBURY STYLE B 3 PIECE BALL VALVE 3/4"-4C2236XT-1 OR EQUIVALENT WITH REINFORCED TEFLON SEAT, SOCKET WELDED, 4 BOLT CLAMP, C.S. BODY WITH S.S. BALL AND TRIM. ISOLATION VALVE ON EACH TRAP ASSEMBLY 3/4" SCH. 80 C.S. A-106 GR. B OR A-53 GR. B PIPE. WATSON MCDANIEL THERMO-DYNAMIC STEAM TRAP - 3/4" WD-450 C/W CARBON STEEL CONNECTORS SW CONNECTIONS, INTERGAL STRAINER AND BLOWDOWN VALVE 2" - SAME AS ITEM #1. 3/4" CHECK VALVE - NEWMANS FIG. 38S-FS2 OR APPROVED EQUAL - SWING/TITLING DISC WITH CS BODY, AND CHROME TRIM INSTALL TRAP ASSEMBLIES TO DRIP LEGS ON STEAM PIPING AND EXPANSION JOINTS. 2" SOCKOLET MAIN STEAM LINE DIA DRIPLEG DIA 10" 12" 8" 8"12"2 12"3"3/4" SOCKOLETS (2 TYP) 2"-4"1/4" EXPANSION PIPE ANCHOR MOVEMENT THIS SIDEPIPE THIS SIDE SUPPORT DRILL (4) 'G' DIA HOLES - CONTRACTOR TO SUPPLY AND INSTALL ST. STL. HILTI HDI ANCHORS MIN. EMBEDMENT = 4" (4 REQ'D) C F D I H PIPE SIZE DIMENSIONS (inches)GRAPHITE BEARING AREA (sq. in.> DIMENSIONS (inches)MAX HORIZONTAL SUPPORT SPACING WATER/VAPOR (ft.) PIPE SIZE A C D E F G H I J K 12 11 3/4 12 5 3/4 3 1/4 7/8 24 22 20 12 3/4 23/30 12EJ (GROUT)PIPE AKGALVANIZED PIPE SUPPORT MANUFACTURED TO DIMENSIONS SHOWN PADS AND BE EPOXY BONDED AND UPPER AND LOWER COMPONENTS MECHANICALLY ATTACHED TO BE PROVIDED WITH 1/2" THICK GRAPHITE 1/4" L 3/8 L (PL. THK.) L (PL. THK.) M 1 7/8 M (AEROGEL INSULATION THK.) 1 Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624AUG. 2020 NONE BGBG/AB AB M-501 MECHANICAL DETAILS SHEET 1 ITHACA, NEW YORK CORNELL UNIVERSITY H.P. STEAM BUTTERFLY VALVE INSTALLATION DETAIL H.D.P.E. TO STEEL WITH AWWA D.I. VALVE DETAIL <12"Ø PIPE DETAIL # 4.1.4a STEEL PIPE WITH AWWA D.I. VALVE DETAIL <12"Ø PIPE DETAIL # 4.1.5a CHILLED WATER WALL PENETRATION DETAIL DETAIL # 4.1.3 TYPICAL STEAM TRAP AND DRIP LEG DETAIL CONDENSATE RECEIVER AND METER DETAIL DETAIL # 3.2.2 TYPICAL STEAM PIPE TUNNEL SECTION #2 TYPICAL STEAM PIPE SUPPORT W/ AEROGEL INSUL. DETAIL # 4.4.1S.A TYPICAL STEAM PIPE TUNNEL SECTION #1 Drawing Copyright © 2019Designed By:Checked By:Drawing No.:Issue Date:Designed By:Drawn By:Project No:Scale:No.ByDateSubmittal / RevisionCORNELL UNIVERSITYITHACA, NEW YORKKENNEDY HALL TO CLARKHALL THERMAL SYSTEMUPGRADEApp'd.www.chacompanies.com441 South Salina Street Syracuse, NY 13202-4712Main: (315) 471-392060624AUG. 2020NONEBGBG/ABABM-502MECHANICAL DETAILSSHEET 2ITHACA, NEW YORKCORNELL UNIVERSITY Drawing Copyright © 2019Designed By:Checked By:Drawing No.:Issue Date:Designed By:Drawn By:Project No:Scale:No.ByDateSubmittal / RevisionCORNELL UNIVERSITYITHACA, NEW YORKKENNEDY HALL TO CLARKHALL THERMAL SYSTEMUPGRADEApp'd.www.chacompanies.com441 South Salina Street Syracuse, NY 13202-4712Main: (315) 471-392060624JUL. 2020AS NOTEDBGBG/ABABM-600PIPE SUPPORT DETAILSSHEET 1ITHACA, NEW YORKCORNELL UNIVERSITY Drawing Copyright © 2019Designed By:Checked By:Drawing No.:Issue Date:Designed By:Drawn By:Project No:Scale:No.ByDateSubmittal / RevisionCORNELL UNIVERSITYITHACA, NEW YORKKENNEDY HALL TO CLARKHALL THERMAL SYSTEMUPGRADEApp'd.www.chacompanies.com441 South Salina Street Syracuse, NY 13202-4712Main: (315) 471-392060624JUL. 2020AS NOTEDBGBG/ABABM-601PIPE SUPPORT DETAILSSHEET 2ITHACA, NEW YORKCORNELL UNIVERSITY Drawing Copyright © 2019Designed By:Checked By:Drawing No.:Issue Date:Designed By:Drawn By:Project No:Scale:No.ByDateSubmittal / RevisionCORNELL UNIVERSITYITHACA, NEW YORKKENNEDY HALL TO CLARKHALL THERMAL SYSTEMUPGRADEApp'd.www.chacompanies.com441 South Salina Street Syracuse, NY 13202-4712Main: (315) 471-392060624JUL. 2020AS NOTEDBGBG/ABABM-602PIPE SUPPORT DETAILSSHEET 3ITHACA, NEW YORKCORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624JUL. 2020 AS NOTED S-001 STRUCTURAL NOTES ITHACA, NEW YORK CORNELL UNIVERSITY RKJT JT Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624JUL. 2020 AS NOTED RKJT JT S-100 STRUCTURAL STEAM TUNNEL DETAILS ITHACA, NEW YORK CORNELL UNIVERSITY Drawing Copyright © 2019 Designed By:Checked By: Drawing No.: Issue Date: Designed By:Drawn By: Project No:Scale: No.By DateSubmittal / Revision CORNELL UNIVERSITY ITHACA, NEW YORK KENNEDY HALL TO CLARK HALL THERMAL SYSTEM UPGRADE App'd. www.chacompanies.com 441 South Salina Street Syracuse, NY 13202-4712 Main: (315) 471-3920 60624JUL. 2020 AS NOTED S-101 STRUCTURAL STEAM TUNNEL ANCHOR DETAILS ITHACA, NEW YORK CORNELL UNIVERSITY RKJT JT