HomeMy WebLinkAboutOLIN HALL B40B LAB RENOVATION_100% CD SET_SIGNED (2)CB CBCB
CB CB
CB CB
CB CB
CB CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CBCB
CB
CB
CB
CB
CB
191920202021212121202020201919
191920202021212121202020201919
191920202021212121202020201919
191920202021212121202020201919
1919202020212121212020202019191919212020202021
2121212121212121212121212121
PAVED
PARKING
UNPAVED PARKING
UNPAVED PARKING
PAVED
ROCKS
PLATFORM
TENNIS COURTS
SS
S
SIGN
101
102104
103105
106108
107
110114
116120
120B
124
126
128
130
132
142
144
148
115
145
145B
155B
155 155A
165
165B
167E
167D
167C
167B
167A168169170B170A
170
160162
152
100CD
100EB
100CE
167
167F
100JA
100UA
100UB
100SA
100CJ
100CG
100UF
100CK
100CA100CF
100CL
100CN
100UC
100SB
100JC
100SC
100CC
100TC
100TA
100JB100UD
100TB
145A
100CM
167G
100TD
142A
148A
158
158B
156
100UR
146
100CA
B00SE
148B
136
OPEN TOBELOW
111
100EA
100CP
UP
UP
DN
UP
UP
DN
UP
UPDN
UP
DN
UP
DN
DN
B00EA
B00CC
B00SC
B00JB
B01
B02B06
B05
B08B14
B40A
B40
B40B
B49
B53
B55
B57
B78
B59
B00UA
B56
B54
B52
B50
B48
B46
B00UC
B40C
B00UL
B14B
B14A
B00UM
B00CD
B00UN
B00US
B00EB
B00TA
B00UH
B00TB
B00UG
B00UP
B00UF
B00JA
B00SB
B00CA
B00SA
B00UB
B00UE
B00UD
B00JC
B00UR
B14C
B00CA
B00CA
B11
B00SE
UP
UP
UP
UP
2024
OLIN HALL
CAMPUS ROAD
EXTERIOR ELEVATION
1
X-100
X-100
1
1 INTERIOR ELEVATION
1
X-100
SECTION MARKER
1
X-100 ENLARGED DETAIL
CONSTRUCTION KEYED NOTE
DEMOLITION KEYED NOTE
DRAWING REVISION NOTE
LINETYPE: TO BE PROVIDED / NEW
LINETYPE: DEMOLITION / TO BE RELOCATED
LINETYPE: EXISTING TO REMAIN
#
#
#
1
1
1
11
AREA OF WORK
AREA OF WORK
T-001 TITLE SHEET
ARCHITECTURAL
A-001 GENERAL NOTES, SYMBOLOGY, ABBREVIATIONS AND DOOR SCHEDULE
A-002 CODE COMPLIANCE/ CONTROL AREA PLANS - BASEMENT & FIRST FLOOR
A-101 PARTIAL BASEMENT DEMOLITION PLAN - ROOM B40 & B40B
A-102 PARTIAL BASEMENT RENOVATION PLAN AND FIRST FLOOR EQUIPMENT PLAN
A-103 REFLECTED CEILING PLAN
MECHANICAL
M-001 GENERAL NOTES AND SYMBOL LEGENDS
M-101 PARTIAL BASEMENT MECHANICAL FLOOR PLANS
M-401 MECHANICAL BUILDING AUTOMATION AND CONTROL SYSTEM DETAIL
M-501 SCHEDULES
ELECTRICAL
E-001 GENERAL NOTES AND SYMBOL LEGENDS
E-101 ELECTRICAL DEMOLITION & RENOVATION PLANS
E-501 SCHEDULES & DETAILS
PLUMBING
P-001 GENERAL NOTES AND SYMBOL LEGENDS
P-101 PARTIAL BASEMENT AND FIRST FLOOR PLUMBING PLANSCORNE
LL U N I V
E
R
SI
TYFOUN
D E D 5681
AD CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
Cornell University
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
T-001
12809855
TITLE SHEET
FE DESIGN
JGC
2024
OCTOBER 12, 2020
OLIN HALL B40B LAB RENOVATION
BUILDING CODE SUMMARY
APPLICABLE CODES
2020 NYS BUILDING CODE
2020 NYS EXISTING BUILDING CODE
2020 NYS FIRE CODE
2020 NYS PLUMBING CODE
2020 NYS MECHANICAL CODE
2020 NYS ENERGY CONSERVATION CODE
2009 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
2010 AMERICANS WITH DISABILITY ACT (ADA)
PROJECT SUMMARY
THIS PROJECT INCLUDES THE RENOVATION OF ABOUT 1,500 SF OF
LABORATORY AND OFFICE SPACES.
ALTERATION LEVEL 2:
LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE,
THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE
RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION
OF ANY ADDITIONAL EQUIPMENT. AN EXISTING BUILDING OR PORTION
THEREOF SHALL NOT BE ALTERED SUCH THAT THE BUILDING BECOMES
LESS SAFE THAN ITS EXISTING CONDITIONS.
BUILDING LIMITATIONS
CONSTRUCTION CLASSIFICATION:IIA
CLASSIFICATION OF HAZARDS:MAQ IN PROGRESS
HIGH-RISE BUILDING:NO
EXTINGUISHING REQUIREMENT:THE EXISTING BUILDING IS FULLY
SPRINKLERED.
OCCUPANCY OF AREA OF WORK
OCCUPANCY CLASSIFICATION:BUSINESS (B /
HIGHER EDUCATION LABORATORY)
GENERAL SYMBOLS LEGEND
DRAWING INDEX
PROJECT SCOPE
THE PURPOSE OF THIS PROJECT IS TO RENOVATE LABORATORY SPACE B40B AND ADJACENT OFFICE SPACE ROOM B40 IN OLIN HALL.
THE MAJORITY OF DEMOLITION AND NEW WORK TAKES PLACE IN ROOM B40B AND B40, WHILE SOME LAB EQUIPMENT WILL BE INSTALLED IN ROOM 108 AS
IDENTIFIED IN THIS SET OF DOCUMENTS. EXISTING CONDITIONS IN ROOM 108 WILL REMAIN IN TACKED.
SITE LOCATION -OLIN HALL 2024
KEY PLANS
OLIN HALL -BASEMENT OLIN HALL -FIRST FLOOR
1 08/04/2020 ISSUE FOR DD REVIEW
2 09/01/2020 ISSUE FOR 90% REVIEW
3 09/29/2020 ISSUE FOR COORDINATED REVIEW
4 10/12/2020 ISSUE FOR CONSTRUCTION
WALL -EXISTING
WALL -METAL STUD/ GWB
WALL -CONCRETE
WALL -CMU
WALL -BRICK
ITEMS FOR DEMOLITION
DOOR/ WALL -EXISTING
DOOR/ WALL -NEW
DOOR/ WALL -DEMOLITION
TAG -DOOR
TAG -WINDOW
TAG -WALL
TAG -ROOM #
CENTER LINE
PHOTO REFERENCE
LEVEL MARKER
COLUMN GRID MARKER
ELEVATION MARKER
ELEVATION CHANGE ARROWS
BREAK LINE
SYMBOLS
0' -0"
101
1t
X-X
X
2B00UA
CL
1
Name
Elevation
A101 1
1
1
0
DN
UP
1
11
1
ABBREVIATIONS
A
&AND
@ AT
ACT ACOUSTICAL CEILING TILE
ALT ALTERNATE
ALUM ALUMINUM
AVG AVERAGE
AFF ABOVE FINISH FLOOR
B
BD BOARD
BLDG BUILDING
BOD BOTTOM OF DECK
BSMT BASEMENT
C
CG CORNER GUARDS
CJ CONTROL JOINT
CLG CEILING
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONF CONFERENCE
CONT CONTINUOUS
CORR CORRIDOR
CPT CARPET
CRS COURSE(S)
CT CERAMIC TILE
D
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DO DOOR OPENING
DWG DRAWING
E
EA EACH
EJ EXPANSION JOINT
ELEC ELECTRIC
ELEV ELEVATION/ ELEVATOR
EPDM RUBBER ROOF MEMBRANE
EQ EQUAL
EX'G EXISTING
EXT EXTERIOR
F
FD FLOOR DRAIN
FDN FOUNDATION
FEC FIRE EXTINGUISHER CABINET
FFE FINISH FLOOR ELEVATION
FRP FIBER REINFORCED POLYESTER
FT FOOT/FEET
FTG FOOTING
G
GA GAGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERAL
GL GLASS
GWB GYPSUM WALL BOARD
H
HC HANDICAPPED
HT HEIGHT
HM HOLLOW METAL
HR HOUR
HVAC HEATING, VENTILATING & AC
J
JAN JANITOR
L
LAV LAVATORY
LB/#POUND
LGMF LIGHT GAGE METAL FRAMING
M
MFR MANUFACTURER
MAT MATERIAL
MAX MAXIMUM
MEZZ MEZZANINE
MIN MINIMUM
MO MASONRY OPENING
MTL METAL
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NR NOT RATED
NTS NOT TO SCALE
O
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OSB ORIENTER STRAND BOARD
P
+/-PLUS OR MINUS
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
Q
QTY QUANTITY
R
R RISER
RD ROOF DRAIN
REF REFRIGERATOR
REQ REQUIRED
REV REVISION
RO ROUGH OPENING
RTU ROOF TOP UNIT
S
SHTG SHEATHING
SIM SIMILAR
SF SQUARE FOOT/ FEET
SS STAINLESS STEEL
STL STEEL
STD STANDARD
T
T TREAD
T&G TONGUE & GROOVE
TEL TELEPHONE
TEMP TEMPERATURE
TOS TOP OF STEEL
TV TELEVISION
TYP TYPICAL
U
UEV UNEVEN DOORS W/ VISION PANEL
UEF UNEVEN FLUSH DOOR
V
VCT VINYL COMPOSITION TILE
VIF VERIFY IN FIELD
W
W/O WITHOUT
WD WOOD7' - 0"3' - 0"
3' - 4"
2"3' - 0"2"7' - 2"7' - 0"2"FG
F-1 7' - 0"3' - 6"
FG/ F-2
ALTERNATE #1
3' - 6"
7' - 0" 7' - 0"3' - 0"
FG/ F-1
ALTERNATE #1
3' - 0"
6' - 0"
7' - 4"
2"7' - 0"2"7' - 2"7' - 0"2"F-3
ALTERNATE #1
6' - 4"
2"6' - 0"2"7' - 2"7' - 0"2"F-2
ALTERNATE #1
5 5/8"5 5/8"10 5/8"7 5/8"S-1 S-1 S-1
B40 B40.1 B40C
VERIFY EXISTING FRAME7' - 0"3' - 6"
F
3' - 6"
VERIFY EXISTING FRAME
7' - 0"
B00CD
PROVIDE GRAPHIC
AS REQUIRED BY
PART 47 OF THE
NEW YORK STATE
DEPARTMENT OF
LABOR.CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
A-001
12809855
GENERAL
NOTES,
SYMBOLOGY,
ABBREVIATIONS
AND DOOR
SCHEDULE
J. COOLBAUGH
JGC
2024
OCTOBER 12, 2020
SCOPE OF WORK
1.0 REMOVE CASEWORK FROM ROOM B40.
2.0 PROVIDE NEW CASEWORK IN ROOM B40B.
3.0 PROVIDE NEW FINISHES IN ROOM B40.
4.0 PROVIDE NEW LASER CURTAIN SYSTEM IN ROOM B40B.
GENERAL NOTES
1.0 DESIGN, CONSTRUCTION AND SAFETY SHALL CONFORM TO ALL LOCAL, STATE AND
OWNER SPECIFIC CODES, INCLUDING (BUT NOT LIMITED TO) THE NEW YORK STATE
UNIFORM FIRE PROTECTION AND BUILDING CODE, LATEST REVISION, THE NFPA 101
LIFE SAFETY CODE, LATEST REVISION, ANSI A117.1 - LATEST REVISION, OSHA, AND
ANY OTHER CODES GOVERNED BY THE JURISDICTION IN WHICH THIS PROJECT IS
BEING CONSTRUCTED.
2.0 THIS CONTRACT REQUIRES COMPLETE, FINISHED WORKABLE PROJECT OF THE
AREAS INDICATED BY THE CONTRACT DOCUMENTS, AND SHALL INCLUDE ALL
MATERIALS AND LABOR NECESSARY TO COMPLETE, REGARDLESS OF WHETHER OR
NOT ALL WORK OR EACH ITEM IS SPECIFICALLY INDICATED ON ANY OTHER
PORTION OF THE DRAWINGS AND / OR NOTES.
3.0 WHERE MATERIALS REFERENCED ON DRAWINGS, OR NECESSARY TO COMPLETE
THE WORK OF THIS CONTRACT ARE NOT SPECIFIED HEREIN, PROVIDE BEST
QUALITY MATERIALS. WHERE MATERIALS ARE INTENDED TO MATCH EXISTING,
PROVIDE CLOSEST POSSIBLE MATCH, SUBJECT TO OWNER'S APPROVAL. ALL ITEMS
AND WORK ON DRAWINGS ARE NEW, UNLESS INDICATED EXISTING. ALL WORK
WHICH HAS BEEN DAMAGED SHALL BE REPAIRED OR REPLACED AT NO COST TO
THE OWNER. WHERE ITEMS CAN NOT BE REPAIRED TO A ""NEW CONDITION"", OR
WHERE THE STRUCTURAL INTEGRITY HAS BEEN AFFECTED, ITEMS SHALL BE
REPLACED AT NO COST TO THE OWNER.
4.0 CONTRACTOR IS RESPONSIBLE TO VERIFY ALL SITE, FIELD AND BUILDING
CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. IF THERE ARE
ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS, NOTIFY THE
PROJECT MANAGER, WHO WILL REQUEST CLARIFICATION FROM THE
ARCHITECT/ENGINEER AND PROVIDE CLARIFICATION IN WRITING.
5.0 WHERE EXISTING CONSTRUCTION OR ITEMS HAVE BEEN INFILLED, REMOVED AND /
OR DISTURBED FOR INSTALLATION OF NEW WORK, CAUSING THE EXPOSURE OF
UNFINISHED AND/OR DAMAGED SURFACES RESULTING SURFACES AND INFILLED
SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED
AREAS. ALL ABANDONED OPENINGS (i.e. DUCT/PIPE REMOVALS, ETC.) AT WALLS,
ROOF OR FLOOR TO BE INFILLED SOLID.
6.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE WORK OF
OTHER TRADES (i.e. ELECTRICAL, MECHANICAL). ALTHOUGH NOT NECESSARILY
SHOWN ON DRAWINGS, WORK IS REQUIRED IN THESE AREAS CONSISTING OF
REMOVAL / REPLACEMENT OF CEILINGS, WALLS, FINISHES, PAVEMENT AND OTHER
CONSTRUCTION AS NECESSARY TO PERFORM WORK AND RESTORE THESE
SPACES OR AREAS TO ORIGINAL CONDITION.
7.0 GENERAL CONTRACTOR IS TO COORDINATE WORK OF ALL TRADES. SCHEDULE
WORK PROGRESS THROUGHOUT THE ENTIRE PROJECT TO PREVENT CONFLICTS
AND INTERFERENCES. OBTAIN ALL NECESSARY INFORMATION SUCH AS SIZES,
LOCATIONS, TEMPLATES, LAYOUT, DIMENSIONS AND ALL OTHER INFORMATION
NECESSARY FOR A PROPER AND WELL COORDINATED INSTALLATION. PRIOR TO
INSTALLATION OF ITEMS, VERIFY AND CONFIRM WITH EACH CONTRACTOR EXACT
LOCATION OF ALL ITEMS.
8.0 ALL PENETRATIONS (EXISTING OR NEW) THROUGH FLOORS AND FULL HEIGHT
WALLS - IN AREA OF WORK TO BE FIRE STOPPED. ALL GAPS AND JOINTS AT RATED
FLOORS, ROOFS AND WALLS TO BE FIRE & SMOKE STOPPED. GAPS AND JOINTS
INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL
TO BEAMS, AND CONTROL OR EXPANSION JOINTS. FIRE STOPPING INCLUDES BOTH
FORM OR PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. PROVIDE
AND INSTALL LABELING REQUIRED BY CODE. LABELS SHALL INCLUDE
PENETRATION TYPE WITH UL LISTING USED, MATERIAL USED, DATE INSTALL AND
NAME OF INSTALLER.
9.0 JOBSITE WILL BE CLEANED DAILY AND DEBRIS REMOVED TO CONTAINERS OR TO
VEHICLE WHICH WILL REMOVE DEBRIS FROM CAMPUS. CONTAINERS WILL BE
REMOVED AS SOON AS FULL OR WHEN THE PROJECT HAS PROGRESSED TO A
POINT THAT A CONTAINER IS NO LONGER REQUIRED.
10.0 CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL AREAS USED TO BRING
SUPPLIES AND EQUIPMENT INTO THE PROJECT AREA. ANY DAMAGE TO AREAS
OUTSIDE THE PROJECT AREA INCLUDING BUT NOT LIMITED TO THE LOBBY AND
CORRIDOR SHALL BE REPAIRED AT NO COST TO THE OWNER.
DOOR / HARDWARE SCHEDULE
DOOR
DOOR FRAME
FIRE RATINGGLAZING TYPEHARDWARE DETAILS
REMARKSDOOR LOCATION HAND
PANEL SIZE
ELEVATION TYPEMATERIALFINISHELEVATION TYPEMATERIALFINISHHEAD DIM.HINGES MCKINNEY TA2714 4.5 X 4.5 X 26DHINGES MCKINNEY TA2714 X 4.5 X 4.5 X NRP X 26D FIELD VERIFY DIMENSIONSFLUSH BOLT DCI 780F X 26DLOCKSET SARGENT 70-8205 X WTL X LHRB X 26DLOCKSET SARGENT 70-8205 X WTL X RH X 26DLOCKSET SARGENT 70-8215 X WTL X LH X 26DLOCKSET SARGENT 70-8205 X WTL X LH X 26DBEST RESTRICTED CYLINDERS PROVIDE BY THE EN ZONECLOSER SARGENT 351 X P X EN X 120 DEGREE WALL BUMPERS DCI 3211T X US26DSILENCERS DCI 8SSELF LATCHING FLUSH BOLTS DCI 845 METAL DOORDOOR COORDINATORS DCI #684MOUNTING BRACKET DCI 600D SERIESELECTROMAGNETIC DOOR HOLDER RIXSON MODEL 997ELECTROMAGNETIC DOOR HOLDER RIXSON MODEL 980HEAD JAMB THRESHOLD# OF PANELSWIDTHHEIGHTTHICKNESSB00CD B00CA TO B00CD LH (2) 3' - 6" 7' - 0" 1 3/4" F HM PT-3 F-3 EX PT-3 EX 45 MIN - - 6 - - - 1 - 1 2 - 2 1 1 1 1 1 5
B40 B40B TO B40 LH (1) 3' - 0" 7' - 0" 1 3/4" FG HM PT-3 F-1 HM PT-3 2 NA S-1 3 - - - - - 1 1 1 1 3 - - - - -
B40.1 B00CD TO B40 RH (2) 3' - 0" 7' - 0" 1 3/4" FG/ F HM PT-3 F-2 HM PT-3 2 NA S-1 - 6 2 - 1 - - 1 2 2 2 - - - - -4
B40C B00CD FROM B40C LHRBA (2) 3' - 6" 7' - 0" 1 3/4" FG/ F HM PT-3 F-3 HM PT-3 2 NA S-1 - 6 2 1 - - - 1 2 2 2 - - - - -1, 3, 4
NOTES:
1. VERIFY ALL HARDWARE DIMENSIONS FOR DOOR B40C.
2. PROVIDE HINGE FILLER PLATE (BY DON-JO OR APPROVED EQUAL) ON FRAME TO REMAIN. VERIFY EXISTING HINGE SIZE. SEE
DEMOLITION PLAN FOR DOOR LOCATION (A-101).
3. BASE BID -REPLACE DOOR HARDWARE ON DOOR B40C ONLY.
4. ALTERNATE #1 -REMOVE AND INSTALL NEW DOORS, FRAMES, AND HARDWARE AT DOORS B40.1 AND B40C. REFER TO RENOVATION
PLAN ON A-102 AND DOOR/ FRAME ELEVATIONS FOR MORE INFORMATION.
5. VERIFY ALL HARDWARE DIMENSIONS FOR DOOR B00CD.
HOLLOW METAL DOORS/ FRAMES:
BASIS OF DESIGN FOR STILE AND RAIL DOORS -CURRIES 767 OR APPROVED EQUAL.
BASIS OF DESIGN FOR NON-RATED FLUSH DOORS -CURRIES 607 OR APPROVED EQUAL.
BASIS OF DESIGN FOR RATED FLUSH DOORS -CURRIES 727 OR APPROVED EQUAL.
• 18 GAUGE MIN. DOOR
• 3' WIDE AND UNDER: 16 GAUGE FRAMES
• OVER 3' WIDE: 14 GAUGE FRAMES
GLAZING:
S-1 -1/4" FULLY TEMPERED SAFETY GLASS
PAINT:
PT-3 PAINT -DOORS AND FRAMES -BLACK
BENJAMIN MOORE, COLOR: XXXX "XXX", SEMI-GLOSS
SCALE:3/8" = 1'-0"
DOOR AND FRAME ELEVATIONS1
SUBMITTAL REGISTRY
SECTION DESCRIPTION REQUIRED SUBMITTALS
03 54 00 - CAST UNDERLAYMENT FLOOR LEVELER PRODUCT DATA
05 50 00 - METAL FABRICATIONS UNISTRUT PLATFORM SYSTEM PRODUCT DATA, SHOP DRAWINGS
07 84 13 - PENETRATION FIRESTOPPING WALL AND FLOOR PENETRATION FIRESTOPPING PRODUCT DATA
07 92 00 - SEALANTS PRODUCT DATA
08 11 13 - HOLLOW METAL DOORS AND FRAMES STILE AND RAIL, FLUSH, AND FRAMES PRODUCT DATA, SHOP DRAWINGS
08 71 00 - DOOR HARDWARE LOCKSETS, HINGES, CLOSERS, AND FLUSH BOLTS PRODUCT DATA
08 80 00 - GLAZING FULLY TEMPERED GLASS PRODUCT DATA
09 65 00 - RESILIENT FLOORING SHEET VINYL AND BASE PRODUCT DATA
09 68 13 - TILE CARPETING CARPET TILE AND VINYL BASE PRODUCT DATA
09 91 23 - INTERIOR PAINTING LATEX PAINT FOR WALLS, DOORS/ FRAMES, AND CABINETS PRODUCT DATA
12 35 53 - LABORATORY CASEWORK ADA SINK CABINET, BASE CABINETS, SHELVING AND COUNTERTOP PRODUCT DATA, SHOP DRAWINGS
1 08/04/2020 ISSUE FOR DD REVIEW
2 09/01/2020 ISSUE FOR 90% REVIEW
3 09/29/2020 ISSUE FOR COORDINATED REVIEW
4 10/12/2020 ISSUE FOR CONSTRUCTION
B00EA
B00CC
B00SC
B00JB
B01
B02B06
B05
B08B14
B40A
B40
B40B
B49
B53
B55
B57
B78
B59
B00UA
B56
B54
B52
B50
B48
B46
B00UC
B40C
B00UL
B14B
B14A
B00UM
B00CD
B00UN
B00US
B00EB
B00TA
B00UH
B00TB
B00UG
B00UP
B00UF
B00JA
B00SB
B00CA
B00SA
B00UB
B00UE
B00UD
B00JC
B00UR
B14C
B00CA
B00CA
B11
B00SE
UP
UP
UP
UP
101
102104
103105
106108
107
110114
116120
120B
124
126
128
130
132
142
144
148
115
145
145B
155B
155 155A
165
165B
167E
167D
167C
167B
167A168169170B170A
170
160162
152
100CD
100EB
100CE
167
167F
100JA
100UA
100UB
100SA
100CJ
100CG
100UF
100CK
100CA100CF
100CL
100CN
100UC
100SB
100JC
100SC
100CC
100TC
100TA
100JB100UD
100TB
145A
100CM
167G
100TD
142A
148A
158
158B
156
100UR
146
100CA
B00SE
148B
136
OPEN TO
BELOW
111
100EA
100CP
UP
UP
DN
UP
UP
DN
UP
UPDN
UP
DN
UP
DN
DN
AREA OF WORK IN ROOMS
B40B AND B40 (LEVEL 2
ALTERATION)
COMMON PATH OF EGRESS: 52 FEET
(IBC 1006.1.2: MAX 100' WITH
SPRINKLER SYSTEM)
TRAVEL DISTANCE TO EXIT: 112 FEET
(IBC 1017.2: MAX 300' WITH
SPRINKLER SYSTEM)
TRAVEL DISTANCE TO EXIT: 80 FEET
(IBC 1017.2: MAX 300' WITH
SPRINKLER SYSTEM)
COMMON PATH OF EGRESS: 30 FEET
(IBC 1006.1.2: MAX 100' WITH
SPRINKLER SYSTEM)
OLIN B-CA2
ESTABLISHED
CONTROL AREA 2020
OLIN B-CA1
ESTABLISHED
CONTROL AREA 2015
OLIN 1-CA1
2020 MODIFICATION (RENOVATIONS TO
ROOM 103, 105, 107 NOT IN SCOPE OF
WORK) OF ESTABLISHED CONTROL
AREA 2014
OLIN 1-CA2
2020 MODIFICATION (THIS PROJECT)
OF ESTABLISHED CONTROL AREA
2014
AREA OF WORK IN ROOM 108 (LEVEL 2
ALTERATION)
COMMON PATH OF EGRESS: 27 FEET
(IBC 1006.1.2: MAX 100' WITH SPRINKLER SYSTEM)
TRAVEL DISTANCE TO EXIT: 95 FEET
(IBC 1017.2: MAX 300' WITH SPRINKLER SYSTEM)
1-HOUR FIRE SEPARATION
2-HOUR FIRE SEPARATION
TRAVEL DISTANCE TO EXIT
COMMON PATH OF EGRESS
AREA OF WORK -LEVEL 2 ALTERATION
CONTROL AREA - OLIN 1-CA2
CONTROL AREA -OLIN 1-CA1
CONTROL AREA -OLIN B-CA1
CONTROL AREA -OLIN B-CA2 CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
A-002
12809855
CODE
COMPLIANCE/
CONTROL AREA
PLANS -
BASEMENT &
FIRST FLOOR
J. COOLBAUGH
JGC
2024
OCTOBER 12, 2020
SCALE:1/16" = 1'-0"1 CODE COMPLIANCE/ CONTROL AREA PLANS - BASEMENT
SCALE:1/16" = 1'-0"2 CODE COMPLIANCE/ CONTROL AREA PLANS - 1ST FLOOR
0' 8'16' 32'
SCALE: 1/16"=1'-0"
CODE COMPLIANCE KEY
1 08/04/2020 ISSUE FOR DD REVIEW
2 09/01/2020 ISSUE FOR 90% REVIEW
3 09/29/2020 ISSUE FOR COORDINATED REVIEW
4 10/12/2020 ISSUE FOR CONSTRUCTION
2
1
3
5
4
9
B40B
B40
B00JC
B00CD
B40C
B40A
B00UH
B00UF
5
6
7
8
8
8
10
10
10
11
12
13
13
EXISTING FLOORING TO REMAIN PREP FLOOR FOR NEW FLOORING ALTERNATE #2V.I.F.7' - 5" +/-14
15
A-101
2
A-101 3 A-1014
A-1015
A-1016
A-1017
A-101
8
7
9
9 4 1313
1
3
11
2
15
3
11
2
10
CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
A-101
12809855
PARTIAL
BASEMENT
DEMOLITION
PLAN - ROOM B40
& B40B
J. COOLBAUGH
JGC
2024
OCTOBER 12, 2020
A-101 KEYED DEMOLITION NOTES
1 REMOVE EXISTING DOOR AND FRAME.
2 REMOVE EXISTING VCT. PREP FLOOR FOR NEW FLOOR FINISH.
3 REMOVE EXISTING BASE CABINETS.
4 REMOVE EXISTING DOOR HARDWARE ONLY, DOOR AND FRAME TO REMAIN. BASE
BID.
5 REMOVE EXISTING WALL CABINET.
6 REMOVE EXISTING TALL CABINET.
7 REMOVE EXISTING FLOOR ANCHOR BOLTS. PATCH FLOOR WITH REPAIR MORTAR
TO MATCH EXISTING ADJACENT CONDITION.
8 EXISTING WALL CABINET TO REMAIN. PREP FOR PAINTING.
9 REMOVE EXISTING DOOR AND HARDWARE ONLY. FRAME TO REMAIN. TURN DOOR
AND HARDWARE OVER TO OWNER.
10 REMOVE EXISTING CURTAIN TRACK TO THE LIMITS SHOWN. PREP FOR NEW LASER
TRACK.
11 EXISTING COUNTERTOP TO BE ABATED UNDER A SEPERATE CONTRACT.
12 REMOVE A PORTION OF EXISTING GYPSUM WALL BOARD TO PROVIDE ACCESS FOR
PLUMBING. COORDINATE LOCATION WITH PLUMBING DRAWINGS.
13 REMOVE EXISTING DOORS AND FRAME AS PART OF ALTERNATE #1.
14 REMOVE EXISTING DOORS AND HARDWARE. EXISTING FRAME TO REMAIN.
15 REMOVE EXISTING PEGBOARD.
#
0' 2' 4' 8'
SCALE: 1/4"=1'-0"
SCALE:1/4" = 1'-0"1 PARTIAL BASEMENT DEMOLITION PLAN - ROOM B40 & B40B
A-101 GENERAL DEMOLITION NOTES
1.0 CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO THE START OF
DEMOLITION.
2.0 CONTRACTOR SHALL COORDINATE REMOVALS WITH ALL ASSOCIATED
CONTRACTORS PRIOR TO DEMOLITION.
3.0 CONTRACTOR IS RESPONSIBLE TO REPAIR ANY DAMAGED SUSTAINED TO
ADJACENT EXISTING CONDITIONS DURING THE REMOVAL OF EXISTING BUILDING
ELEMENTS.
NOT TO SCALE2DEMO PHOTO
NOT TO SCALE3DEMO PHOTO
NOT TO SCALE4DEMO PHOTO
NOT TO SCALE5DEMO PHOTO
NOT TO SCALE6DEMO PHOTO
NOT TO SCALE7DEMO PHOTO
NOT TO SCALE8DEMO PHOTO
1 08/04/2020 ISSUE FOR DD REVIEW
2 09/01/2020 ISSUE FOR 90% REVIEW
3 09/29/2020 ISSUE FOR COORDINATED REVIEW
4 10/12/2020 ISSUE FOR CONSTRUCTION
1270 SF
EXG
RSV
B40B
VB
PT-1
529 SF
EXG
CPT
B40
VB
PT-1
B40C
B00CD
B40A
B00UH
B00UF
B00JC
B40
1
2
6
4
55' - 1 1/4"1' - 8 1/2"3' - 0 7/8"
3' - 6"14' - 2"2' - 6"
2
2
2
3
3
3
3
3
7
7
10 3' - 6 1/4"9' - 7 1/4"1' - 0 1/2"
A-102 3
8
3
9
9
14
14
11
B40.1
B40C
V.I.F.7' - 5" +/-EXISTING FLOORING TO REMAIN NEW SHEET VINYL FLOORING ALTERNATE #212
12
EXISTING
FLOORING
TO REMAIN
NEW SHEET
VINYL FLOORING
ALTERNATE #2
E4.1
E6
E4
E5
E3
E2
B00CD
13
15
15
15
LIMIT OF CORRIDOR WORKB00CA
16
B40
34"36"BC-1
48"
BC-2
48"
BC-3
36"
BC-4
36"
18" DEEP OPEN
SHELVING, BASIS OF
DESIGN: SIGMA FLEX BY
MOTT MANUFACTURING
OR APPROVED EQUAL
ADA STEEL
BASE CABINET
TRESPA TOPLAB OR
APPROVED EQUAL 30"
DEEP COUNTERTOPS
WITH 4" BACKSPLASH
RACEWAY -REFER
TO ELECTRICAL
DRAWINGS
PEGBOARD PROVIDE HINGE
FILLER PLATES AND
PAINT FRAME PT-3,
REFER TO A-001 FOR
MORE INFORMATION
NEW HOLLOW METAL
STILE AND RAIL DOOR
AND FRAME, PAINT PT-3.
REFER TO A-001 FOR
MORE INFORMATION
EYE WASH AND FAUCET,
REFER TO PLUMBING
DRAWINGS FOR MORE
INFORMATION
PT-1
ROOM
NUMBER
CEILING
FINISH
WALL
FINISH
FLOOR
FINISH
WALL
BASE
ROOM
AREA
108
E1
E1.2
E1.3 CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
A-102
12809855
PARTIAL
BASEMENT
RENOVATION
PLAN AND FIRST
FLOOR
EQUIPMENT
PLAN
J. COOLBAUGH
JGC
2024
OCTOBER 12, 2020
0' 2' 4' 8'
SCALE: 1/4"=1'-0"
SCALE:1/4" = 1'-0"1 PARTIAL BASEMENT RENOVATION PLAN - ROOM B40 & B40B
A-102 KEYED RENOVATION NOTES
1 PATCH EXISTING WALL WHERE CASEWORK WAS REMOVED. MATCH EXISTING
ADJACENT CONDITIONS. SPACKLE, SAND, PRIME AND PAINT 2 COATS ENTIRE WALL
OR TO LIMITS SHOWN.
2 OWNER PROVIDED LASER CURTAIN (SLC-250W-B) AND MOUNTING SYSTEM (SLCTA)
BY KENTEK OR APPROVED EQUAL. OWNER PROVIDED LASER CURTAIN INTERLOCK
SYSTEM BY LASER SAFETY SYSTEMS OR APPROVED EQUAL. CONTRACTOR TO
INSTALL LASER CURTAIN AS PER MANUFACTURER'S INSTRUCTIONS.
3 NEW FURNITURE BY OWNER.
4 PROVIDE NEW CARPET TILE. SEE SPECS (THIS PAGE) FOR MORE INFORMATION.
5 PROVIDE NEW DOOR HARDWARE. REFER TO DOOR SCHEDULE A-001 FOR MORE
INFORMATION.
6 PATCH APPROX 8 HOLES IN FLOOR WITH EUCLID TAMMS THIN PATCH
POLYMER-MODIFIED MULTI-USE REPAIR MORTAR OR APPROVED EQUAL. MATCH
EXISTING ADJACENT FLOOR CONDITIONS.
7 EXISTING WALL CABINET TO REMAIN. PREP FOR PAINTING. REFER TO SPECS (THIS
PAGE) FOR PAINT INFORMTAION
8 PATCH WALL WHERE PLUMBING WAS INSTALLED. MATCH EXISTING ADJACENT
CONDITIONS. SPACKLE, SAND, PRIME AND PAINT 2 COATS ENTIRE WALL OR TO
LIMITS SHOWN.
9 OWNER SUPPLIED NEW EQUIPMENT AND CONTRACTOR INSTALLED.
10 EXISTING WALL CABINET TO REMAIN.
11 PATCH WALL WHERE PLUMBING WAS REMOVED. MATCH EXISTING ADJACENT
CONDITIONS. SPACKLE, SAND, PRIME AND PAINT 2 COATS ENTIRE WALL OR TO
LIMITS SHOWN.
12 PROVIDE NEW DOORS AND FRAMES. REFER TO DOOR SCHEDULE/ ELEVATIONS
A-001 FOR MORE INFORMATION. ALTERNATE #1
13 PROVIDE NEW FIRE RATED DOORS. REFER TO DOOR SCHEDULE/ ELEVATIONS A-001
FOR MORE INFORMATION.
14 OWNER SUPPLIED EXISTING EQUIPMENT AND CONTRACTOR INSTALLED.
15 FILL ALL VOIDS AND PENETRATIONS THAT ARE NOT FIRE CAULKED ALONG ENTIRE
WALL. EXISTING WALLS NEEDS TO MAINTAIN MIN 1 HOUR FIRE RATING.
16 PROVIDE UNISTRUT POLES (TOTAL OF 4) FROM FLOOR TO DECK ABOVE. PROVIDE
ALL HARDWARE TO ANCHOR TO FLOOR AND DECK ABOVE.
#
SCALE:1/4" = 1'-0"3 INTERIOR ELEVATION OF CASEWORK
EXG EXISTING TO REMAIN
PT-1 PAINT -INTERIOR WALLS:
BENJAMIN MOORE, COLOR: 912 "LINEN WHITE"
INTERIOR WALLS: EGGSHELL
PT-2 PAINT -METAL CASEWORK:
BENJAMIN MOORE, COLOR: 912 "LINEN WHITE"
METAL SURFACES: SEMI-GLOSS
PT-3 PAINT -DOORS AND FRAMES -BLACK
BENJAMIN MOORE, COLOR: XXXX "XXX", SEMI-GLOSS
CPT CARPET TILE -TBD
VB VINYL BASE -TBD
RSV RESILIENT SHEET VINYL FLOORING -TBD -ALTERNATE #2
FINISH LEGEND
(BASIS-OF-DESIGN PRODUCTS)
CABINET LEGEND
(BASIS-OF-DESIGN PRODUCTS)
BC-1 MOTT -STEEL ADA COMPLIANT SINK BASE CABINET (158KS22)
COLOR: WHITE
BC-2 MOTT -STEEL BASE CABINET WITH DRAWERS (1510022)
COLOR: WHITE
BC-3 MOTT -STEEL BASE CABINET WITH DRAWERS (1410041)
COLOR: WHITE
BC-4 MOTT -STEEL BASE CABINET WITH DRAWERS (1410014)
COLOR: WHITE
COUNTERTOP -TRESPA TOPLAB, 30" DEEP COUNTERTOPS WITH 4" BACKSPLASH
LAB EQUIPMENT LIST
TAG ROOM FURNISHED BY RIGGED & MOUNTED BY EQUIPMENT DESCRIPTION MANUFACTURER MODEL LOCATION WIDTH (IN) DEPTH (IN) HEIGHT (IN)
E1 108 OWNER OWNER RHEOMETER TA INSTRUMENTS DHR BENCH 14 19 36
E1.2 108 OWNER OWNER RECIRCULATING WATER BATH POLYSCIENCE MX SERIES BENCH - - -
E1.3 108 OWNER OWNER AIR COMPRESSOR JUN-AIR 1770008 UNDER COUNTER 18 28 17
E2 B40B OWNER OWNER LASER COHERENT PL-501 OPTICS TABLE 2 6 3
E3 B40B OWNER OWNER SYRINGE PUMP CETONI NEMESYS OPTICS TABLE 3 12 4
E4 B40B OWNER OWNER OPTICS VIBRATION ISOLATION TABLE (PNUEMATIC) NEWPORT RPR-48-8 FLOOR 96 48 36
E4.1 B40B OWNER OWNER OPTICS VIBRATION ISOLATION TABLE (PNUEMATIC) NEWPORT RS2000-48-8 FLOOR 96 48 36
E5 B40B EXISTING OWNER OPTICS VIBRATION ISOLATION TABLE (PNUEMATIC) MELLES GRIOT - FLOOR 96 48 36
E6 B40B EXISTING OWNER OPTICS VIBRATION ISOLATION TABLE (MANUAL) - - FLOOR 96 48 36
SCALE:1/4" = 1'-0"2 PARTIAL FIRST FLOOR EQUIPMENT PLAN
1 08/04/2020 ISSUE FOR DD REVIEW
2 09/01/2020 ISSUE FOR 90% REVIEW
3 09/29/2020 ISSUE FOR COORDINATED REVIEW
4 10/12/2020 ISSUE FOR CONSTRUCTION
F
F
1
1
1
1
2
A-103
2
2
3
3
MODIFY EXISTING METAL
VALANCE TO ACCOMMODATE
NEW TRACK SYSTEM.
PROVIDE NEW BENT METAL
PANEL TO MATCH RADIUS OF
TRACK. RIVET TO EXISTING
VALANCE.
2
2
2
2
2
2
EXISTING CEILING TILE AND GRID TO REMAIN
EXISTING METAL VALANCE TO REMAIN.
MODIFY VALANCE AT TRACK RADIUS.
PROVIDE CURVED METAL VALANCE TO
MATCH TRACK RADIUS. SEE A1/A-103
REFLECTED CEILING PLAN FOR LOCATION.
OWNER PROVIDED AND CONTRACTOR
INSTALLED, LASER CURTAIN (SLC-250W-B) AND
MOUNTING SYSTEM (SLCTA) BY KENTEK OR
APPROVED EQUAL. OWNER PROVIDED AND
CONTRACTOR INSTALLED, LASER CURTAIN
INTERLOCK SYSTEM BY LASER SAFETY
SYSTEMS OR APPROVED EQUAL.
EXISTING CEILING SUPPORTS TO REMAIN CORNE LL U N IV
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
A-103
12809855
REFLECTED
CEILING PLAN
J. COOLBAUGH
JGC
2024
OCTOBER 12, 2020
0' 2' 4' 8'
SCALE: 1/4"=1'-0"
SCALE:1/4" = 1'-0"1 REFLECTED CEILING PLAN
A-103 KEYED RENOVATION NOTES
1 OWNER PROVIDED AND CONTRACTOR INSTALLED, NEW LASER CURTAIN
(SLC-250W-B) AND MOUNTING SYSTEM (SLCTA) BY KENTEK OR APPROVED EQUAL.
OWNER PROVIDED AND CONTRACTOR INSTALLED, LASER CURTAIN INTERLOCK
SYSTEM BY LASER SAFETY SYSTEMS OR APPROVED EQUAL.
2 PROVIDE HORIZONTAL P1000 SERIES UNISTRUT 6’ LONG AT ROUGHLY 4’ O.C.
ATTACHED TO THE FLOOR/ BEAMS ABOVE WITH (2) UNISTRUT P1049 AND (2) ½” IN.
DIAMETER EXPANSION ANCHORS EACH SIDE, POWER STUD SD2+ BY
POWERS/DEWALT. PROVIDE A MINIMUM 2 ½” INCH OF EMBEDMENT AND INSTALL
PER MANUFACTURER REQUIREMENTS INCLUDING MINIMUM EDGE DISTANCE.
COORDINATE FINAL LOCATIONS WITH OWNER.
3 REINSTALL SUSPENDED CEILING SYSTEM AFTER THE COMPLETION OF
MECHANICAL, ELECTRICAL, AND PLUMBING WORK. REPLACE ANY DAMAGED PIECES
WITH NEW ACOUSTICAL CEILING PANELS AND GRID TO MATCH EXISTING.
#
SCALE:1 1/2" = 1'-0"2 SECTION AT CURTAIN TRACK
SCALE: 1-1/2"=1'-0"
6" 1'0" 3"
1 08/04/2020 ISSUE FOR DD REVIEW
2 09/01/2020 ISSUE FOR 90% REVIEW
3 09/29/2020 ISSUE FOR COORDINATED REVIEW
4 10/12/2020 ISSUE FOR CONSTRUCTION
CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
M-001
12809855
GENERAL NOTES
AND SYMBOL
LEGENDS
S. BURKE
SLB
2024
OCTOBER 12, 2020
MECHANICAL ABBREVIATIONS
BCU BLOWER COIL UNIT
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CC CLEAN CONDENSATE
CO CLEAN OUT
CS CLEAN STEAM
CD CONDENSATE DRAIN
EA EXHAUST AIR
EG EXHAUST AIR GRILLE
FD FIRE DAMPER
GWR GLYCOL HEATING RETURN
GWS GLYCOL HEATING SUPPLY
HPR HIGH PRESSURE STEAM RETURN
HPS HIGH PRESSURE STEAM SUPPLY
HWR HOT WATER HEATING RETURN
HWS HOT WATER HEATING SUPPLY
LPC LOW PRESSURE CONDENSATE
LPS LOW PRESSURE STEAM
MU MAKE UP WATER
MPC MEDIUM PRESSURE CONDENSATE
MPS MEDIUM PRESSURE STEAM
NG NATURAL GAS
PCWR PROCESS CHILLED WATER RETURN
PCWS PROCESS CHILLED WATER SUPPLY
HG REFRIGERANT HOT GAS
RL REFRIGERANT LIQUID
RS REFRIGERANT SUCTION
RAG RETURN AIR GRILLE
SA SUPPLY AIR
SD SUPPLY AIR DIFFUSER
VD VOLUME DAMPER
MECHANICAL SYMBOLOGY
AIRFLOW
BACKFLOW PREVENTER
BALANCE VALVE
BALL VALVE
BOTTOM PIPE CONNECTION
BUTTERFLY VALVE
CAP OR PLUG
CHECK VALVE
CIRCULATING PUMP
DIRECTION OF FLOW
DUCT AIRFLOW
DUCT DOWN (EXHAUST OR RETURN)
DUCT DOWN (SUPPLY)
FIRE AND SMOKE DAMPER IN DUCT
FIRE DAMPER IN DUCT
FLANGE CONNECTION
FLEX CONNECTOR
FLEXIBLE CONNECTION
FLEXIBLE DUCT
FLOW METER
FLOW SWITCH
FUSIBLE LINK VALVE
GLOBE VALVE
MANUAL AIRVENT
ORIFICE METER
PIPE DOWN
PIPE UP
PIPING REDUCER (CONCENTRIC)
PIPING REDUCER (ECCENTRIC)
PRESSURE GAUGE
PRESSURE OR TEMPERATURE PETES PLUG
PRESSURE REDUCING VALVE
PRESSURE SWITCH
RECTANGULAR ELBOW
RECTANGULAR ELBOW WITH TURNING VANES
RELIEF VALVE
SMOKE DAMPER IN DUCT
SOLENOID VALVE
STANDARD BRANCH DUCT
STEAM TRAP
STRAINER (DUPLEX)
STRAINER WITH BLOWDOWN VALVE AND CAP
SUPPLY THROUGH NEXT FLOOR OR ROOF
TEMPERATURE WELL
THERMOMETER
THERMOMETER (DIAL)
TOP PIPE CONNECTION
TRIPLE DUTY VALVE
UNION CONNECTION
VACUUM BREAKER
VOLUME DAMPER IN DUCT
CONTROL SYMBOLOGY
2-WAY CONTROL VALVE, DIGITAL
2-WAY CONTROL VALVE, PNEUMATIC
3-WAY CONTROL VALVE, DIGITAL
3-WAY CONTROL VALVE, PNEUMATIC
ADDRESSABLE OUTPUT MODULE (FIRE ALARM INTERFACE)
AIRFLOW CONTROL VALVE (VENTURI OR VORTEX SHEDDING)
AVERAGING SENSOR
BINARY POINT
BUTTERFLY CONTROL DAMPER
CARBON DIOXIDE SENSOR
CONDENSATE SENSOR
CURRENT SENSOR
DEW-POINT SENSOR
DIFFERENTIAL PRESSURE SENSOR
DIFFERENTIAL PRESSURE SENSOR
ELECTRIC TO PNEUMATIC SWITCH
ELECTRIC TO PNEUMATIC TRANSDUCER
END SWITCH
FLOW ELEMENT (METER)
FLOW SENSOR
HIGH LEVEL SWITCH
HUMIDSTAT SENSOR
LIQUID IMERSION TEMPERATURE SENSOR
LOW LEVEL SWITCH
MODULATING
MOTOR
MOTOR STARTER
NETWORK COMMUNICATION POINT, BACnet MSTP
OCCUPANCY SENSOR
OPEN/CLOSE
OPPOSED BLADE CONTROL DAMPER
PARALLEL BLADE CONTROL DAMPER
PNEUMATIC THERMOSTAT
PRESSURE SENSOR
PRESSURE SWITCH
RELATIVE HUMIDITY SENSOR
RELAY
ROOM TEMPERATURE SENSOR WITH ADJUSTABLE
THERMOSTAT
ROOM TEMPERATURE SENSOR WITH OCCUPANCY
OVERRIDE
ROOM TEMPERATURE SENSOR WITH ON/OFF SWITCH
ROOM TEMPERATURE SENSOR WITH VISUAL DISPLAY
ROTATION DETECTOR
SINGLE POINT SENSOR
SMOKE DETECTOR
SPEED COMMAND
START/STOP
STATIC PRESSURE SENSOR
SWITCH
TEMPERATURE SENSOR
TEMPERATURE SENSOR
TEMPERATURE SENSOR WITH ADJUSTABLE SETPOINT
GENERAL DRAWING SYMBOLOGY
DEMOLISHED WORK
EXISTING PIPING TO REMAIN
EXISTING TO REMAIN
EXISTING WORK TO REMAIN
NEW WORK
POINT OF CONNECTION
POINT OF DISCONNECTION
CONTROL ABBREVIATIONS
AI ANALOG INPUT
AO ANALOG OUTPUT
AV ANALOG VALUE
BI BINARY INPUT
BO BINARY OUTPUT
BV BINARY VALUE
F.L. FAIL LAST
N.C. NORMALLY CLOSED
N.O. NORMALLY OPEN
VFD VARIABLE FREQUENCY DRIVE
MECHANICAL SCOPE OF WORK
1.0 DEMO LAB AIR TRANSFER GRILLES.
2.0 MOVE SUPPLY DIFFUSER AND SUSPEND FOR NEW WORK STATIONS.
3.0 INSTALL EXHAUST GRILLE WITHIN CURTAIN AREA OF B40B TO BALANCE
PRESSURIZATION.
4.0 REBALANCE EXHAUST.
5.0 -.-
6.0 -.-
7.0 -.-
8.0 -.-
9.0 -.-
10.0 -.-
11.0 -.-
12.0 -.-
13.0 -.-
14.0 -.-
15.0 -.-
MECHANICAL GENERAL NOTES
1.0 ALL DUCT DIMENSIONS INDICATED ARE IN INCHES, AND ARE INSIDE FREE AND
CLEAR DIMENSIONS.
2.0 PNEUMATIC TERMINATIONS:
IF COPPER: DEMO BACK TO MAIN AND PROVIDED SOLDERED END CAP
IF POLY: DEMO BACK TO MAIN AND PROVIDE BRASS PLUG
DO NOT USE SHEETMETAL SCREW OR BEND OVER END OF COPPER TUBE.
3.0 INSTALL EQUIPMENT TO ENSURE PROPER ACCESS TO CONTROL DEVICES AND
WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR.
EQUIPMENT THAT IS NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE
RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE
CORRECTED.
4.0 ALL SYSTEM TESTING SHALL BE CONDUCTED PRIOR TO INSULATION,
FIREPROOFING, AND ENCLOSURE IN SHAFTS. ANY RESTORATION WORK REQUIRED
AS A RESULT OF DISTURBING FINISHES OR STRUCTURE IN ORDER TO ACCESS
SYSTEMS REQUIRING REPAIR SHALL BE AT NO COST TO THE UNIVERSITY.
5.0 CUTTING AND PATCHING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
CUTTING, FITTING, AND PATCHING TO COMPLETE THE WORK. WHERE EXISTING
CONSTRUCTION IS REMOVED, CAUSING AN EXPOSURE OF UNFINISHED AND/OR
DAMAGED SURFACES, RESULTING SURFACES SHALL BE RECONSTRUCTED WITH
MATERIALS TO MATCH FINISHED AREAS.
6.0 ANY FIRESTOPPING DISTURBED DURING THE COURSE OF WORK SHALL BE
REPAIRED TO MAINTAIN A 2-HOUR FIRE RATING.
7.0 TESTING AND BALANCING: THE CONTRACTOR SHALL BALANCE ALL AIR SYSTEMS
AS INDICATED. SUBMIT RESULTS OF TESTING AND BALANCING ON STANDARD TAB
CONTRACTOR'S FORMS TO THE ENGINEER FOR REVIEW. SYSTEMS SHALL BE
BALANCED TO WITHIN +/- 10% OF DESIGN VALUES. FINAL BALANCING SHALL OCCUR
AFTER ALL LEAKS IN THE BUILDING ENVELOPE HAVE BEEN IDENTIFIED AND
SEALED.
8.0 SEAL ALL PIPE, GRILLE, DIFFUSER, DUCT, CONDUIT PENETRATIONS WITH
APPROPRIATE MATERIALS (CAULK, FOAM, ETC,) THAT ARE IMPENETRABLE TO THE
CONTAINED ORGANISMS AND WITHSTAND REPEATED DECONTAMINATIONS WITH
CLEANING AGENTS.
MECHANICAL SUBMITTAL SCHEDULE
SECTION TITLE REQUIRED
230000 HEATING, VENTILATING & AIR-CONDITIONING -
230517 SLEEVES AND SLEEVE SEALS FOR HVAC PIPING PRODUCT DATA
230518 ESCUTCHEON FOR HVAC PIPING PRODUCT DATA
230519 METERS AND GAGES FOR HVAC EQUIPMENT PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
230523 GENERAL DUTY VALVES FOR HVAC PIPING PRODUCT DATA
230529 HANGERS & SUPPORTS FOR HVAC PRODUCT DATA
230543 MECHANICAL VIBRATION AND MOVEMENT CONTROL PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
230553 IDENTIFICATION FOR HVAC COMPONENTS PRODUCT DATA
230593 TESTING, ADJUSTING & BALANCING FOR HVAC QUALIFICATIONS, INSPECTION AND TEST REPORTS
230700 HVAC INSULATION PRODUCT DATA
230719 HVAC PIPING & EQUIPMENT INSULATION PRODUCT DATA
230900 INSTRUMENTATION & CONTROL FOR HVAC PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
230920 ANALOG LABORATORY CONTROL PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
230923 DIRECT DIGITAL CONTROL SYSTEM FOR HVAC PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
230924 AUTOMATION & CONTROL SYSTEM PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
231000 FACILITY FUEL SYSTEMS PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
232000 HVAC PIPING AND PUMPS PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
232113 HYDRONIC PIPING PRODUCT DATA
232123 HYDRONIC PUMPS PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
233100 DUCTWORK PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
233113 METAL DUCTS PRODUCT DATA
233116 NONMETAL DUCTS PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
233300 AIR DUCT ACCESSORIES PRODUCT DATA
233400 HVAC FANS PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
233600 AIR TERMINAL UNITS PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
233700 AIR OUTLETS AND INLETS PRODUCT DATA
234000 HVAC AIR CLEANING DEVICES PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
235000 CENTRAL HEATING EQUIPMENT PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
236000 CENTRAL COOLING EQUIPMENT PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
237000 CENTRAL HVAC EQUIPMENT PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
238200 TERMINAL HEATING AND COOLING UNITS PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
238210 FAN COIL COOLING UNITS PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M
239000 UNASSIGNED -
1 08/04/20 ISSUE FOR DD REVIEW
2 09/01/20 ISSUE FOR 90% CD REVIEW
3 09/29/20 ISSUE FOR COORDINATED REVIEW
4 10/12/20 ISSUE FOR CONSTRUCTION
24x14 RA(E)
35x16 SA(E)
44x16 RA(E)20x10 EA(E)20x10 EA(E)35x16 SA(E)32x16 SA(E)29x16 SA(E)27x14 SA(E)23x14 SA(E)
10x10 EA(E)40x12 RA(E)10x8 RA(E)
6ø RA(E)44x12 RA(E)
24x12 EA(E)
20x14 RA(E)
EG-1
1045 CFM
EG-1
1400 CFM
VSV-B40BVEV-B40B
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
SD-1
122 CFM
3
SD-1
100 CFM
2
20x10 EA(E)
EG-2
244 CFM
EG-3
244 CFM
3
UP TO
ABOVE
CEILING
4
SD-1
122 CFM
OS
OS
UP TO
ABOVE
CEILING
1
1
1
1
24x14 RA(E)
35x16 SA(E)
44x16 RA(E)20x10 EA(E)20x10 EA(E)35x16 SA(E)32x16 SA(E)29x16 SA(E)27x14 SA(E)23x14 SA(E)
10x10 EA(E)40x12 RA(E)10x8 RA(E)
6ø RA(E)
44x12 RA(E)
24x12 EA(E)
20x14 RA(E)
2
3
B40B
Room
B40
Room
B40A
Room
B00CD
Room
B00UH
Room
B00UM
Room
3 CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
M-101
12809855
PARTIAL
BASEMENT
MECHANICAL
FLOOR PLANS
S. BURKE
SLB
2024
OCTOBER 12, 2020
#
0' 4' 8'16'
SCALE: 1/8"=1'-0"
M-101 KEYED DEMOLITION NOTES
1 REMOVE TRANSITION GRILLS AND DEMO EXISTING TRANSFER DUCTWORK.
2 REMOVE EXISTING LINEAR SLOT SUPPLY DIFFUER AND FLEX DUCT AND SAVE FOR
REUSE. PREPARE FOR NEW CONSTRUCTION.
3 DEMO SECTION ON 20"X10" EXHAUST DUCTWORK. PREPARE FOR NEW
CONSTRUCTION.
#M-101 KEYED RENOVATION NOTES
1 INSTALL NEW CEILING MOUNTED OCCUPANCY SENSOR SIMILAR TO ACUITY CM-10
PDT IN CENTER OF CEILING TILE AND LOCATE PER MANUFACTURERS
RECCOMENDATIONS. CONNECT TO POWER PACK SIMILAR TO ACUITY SP20. USE ALL
OCCUPANCY SENSORS TO DETERMINE IF ROOM IS OCCUPIED PER CONTROLS
DRAWINGS ON M-401.
2 REUSE EXISTING LINEAR SLOT DIFFUSER AND SUSPEND FROM CEILING BETWEEN
WALL AND 35"X16" DUCTWORK. SUPPORT WITH HANGERS FROM ABOVE. SUPPLY
AIR TO SERVE WORK SPACES BELOW. BALANCE AIRFLOW TO 103 CFM.
3 CONNECT NEW 8" DIAMETER EXHAUST DUCT TO EXISTING 20"X10" EXHAUST DUCT.
INSTALL BALANCING DAMPERS ON EXISTING 20"X10" EXHAUST DUCT AND NEW
8"DIA. EXHAUST DUCT. RUN 8" DIAMETER DUCT BELOW CEILING UNTIL IT CLEARS
STRUCTURAL CEMENT MEMBER. TRANSITION DUCT TO RUN ABOVE CEILING OVER
CURTAIN WALL. INSTALL LINEAR SLOT EXHAUST DIFFUSER IN CEILING TO MATCH
EXISTING LINEAR SLOT SUPPLY DIFFUSER.
4 CONNECT NEW B40B OCCUPANCY SENSORS TO VEV-B40B (EXISTING).
SCALE:1/8" = 1'-0"1 PARITAL BASEMENT CONSTRUCTION PLAN
SCALE:1/8" = 1'-0"2 PARTIAL BASEMENT DEMOLITION PLAN
1 08/04/20 ISSUE FOR DD REVIEW
2 09/01/20 ISSUE FOR 90% CD REVIEW
3 09/29/20 ISSUE FOR COORDINATED REVIEW
4 10/12/20 ISSUE FOR CONSTRUCTION
BACnet / ARCNET
OR BACnet / MSTP
AV: FLOW FEEDBACK (CFM)
AV: POSITION FEEBACK (%)
AV: FLOW SETPOINT (CFM)
BACnet / ARCNET
OR BACnet / MSTP
AV: FLOW FEEDBACK (CFM)
AV: POSITION FEEBACK (%)
AV: FLOW SETPOINT (CFM)
OS
MOD MOD
BI
T
AI
sa
d
COM COM
EVAVSVAV
AI
T
AV
SETPOINT
AO REHEAT COIL AO AO
ANI
T
ANI
H
AV: HEATING STPT
AV: COOLING STPT CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
M-401
12809855
MECHANICAL
BUILDING
AUTOMATION
AND CONTROL
SYSTEM DETAIL
S. BURKE
SLB
2024
OCTOBER 12, 2020
SYSTEM DESCRIPTION
GENERAL EXHAUST AIR VAV (EXISTING)
SUPPLY AIR VAV (EXISTING)
REHEAT COIL (EXISTING)
GENERAL
THE ZONE IS CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS).
ALL SETPOINTS SHALL BE ADJUSTABLE.
THE BACS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM FOR SEVEN DIFFERENT DAILY SCHEDULES PER WEEK.
THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS.
SETPOINTS
SPACE COOLING TEMPERATURE SETPOINTS:
OCCUPIED: 75 °F ± 1.5 °F
OCCUPIED SETBACK: 75 °F + 3 °F
UNOCCUPIED: 75 °F + 6 °F
SPACE HEATING TEMPERATURE SETPOINTS:
OCCUPIED: 70 °F ± 1.5 °F
OCCUPIED SETBACK: 70 °F -3 °F
UNOCCUPIED: 70 °F -6 °F
AIRFLOW SETPOINTS: REFER TO AIRFLOW SCHEDULE
OCCUPANCY SCHEDULE: 6 AM TO 8 PM, MON-FRI
AIRFLOW CONTROL
VAV POSITIONS SHALL BE BASED ON MODE. UNDER NORMAL CONTROL, ROOM OCCUPANCY SHALL BE DETERMINED VIA ROOM OCCUPANCY
SENSORS.
WHEN THE ROOM IS OCCUPIED, THE GENERAL EXHAUST AIR VAV SHALL MODULATE TO MAINTAIN THE OCCUPIED AIR CHANGE RATE. THE
SUPPLY AIR VAV SHALL MODULATE TO MAINTAIN THE INDICATED AIRFLOW DIFFERENTIAL.
WHEN THE ROOM IS UNOCCUPIED, THE GENERAL EXHAUST AIR VAV SHALL MODULATE TO MAINTAIN THE UNOCCUPIED AIR CHANGE RATE.
THE SUPPLY AIR VAV SHALL MODULATE TO MAINTAIN THE INDICATED AIRFLOW DIFFERENTIAL.
RM B40B IS A LAB AND IS DESIGNATED TO MAINTAIN NEGATIVE TO ADJACENT PUBLIC CORRDOR.
SPACE TEMPERATURE CONTROL, HEATING
OCCUPIED HEATING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, AND THE TEMPERATURE FALLS BELOW THE
OCCUPIED SPACE HEATING TEMPERATURE SETPOINT, THE REHEAT COIL CONTROL VALVE SHALL MODULATE AS NEEDED TO MAI NTAIN
THE SPACE AT THE OCCUPIED HEATING TEMPERATURE SETPOINT.
OCCUPIED HEATING SETBACK: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, AND THE TEMPERATURE FALLS
BELOW THE OCCUPIED SETBACK HEATING TEMPERATURE SETPOINT, THE REHEAT COIL CONTROL VALVE SHALL MODULATE AS NEEDED TO
MAINTAIN THE SPACE AT THE OCCUPIED SETBACK HEATING TEMPERATURE SETPOINT.
UNOCCUPIED HEATING: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, AND THE TEMPERATURE FALLS
BELOW THE UNOCCUPIED SPACE HEATING TEMPERATURE SETPOINT, THE REHEAT COIL CONTROL VALVE SHALL MODULATE AS NEEDED TO
MAINTAIN THE SPACE AT THE UNOCCUPIED HEATING TEMPERATURE SETPOINT.
WHEN THE SPACE TEMPERATURE IS AT SETPOINT, THE REHEAT COIL CONTROL VALVE SHALL BE CLOSED.
SPACE TEMPERATURE CONTROL, COOLING
OCCUPIED COOLING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, AND THE SPACE TEMPERATURE RISES ABOVE
THE OCCUPIED COOLING TEMPERATURE SETPOINT, COOLING CONTROL SHALL OVERRIDE AIR CHANGE RATE CONTROL. THE GENERAL
EXHAUST AIR VALVE SHALL MODULATE OPEN AS NEEDED TO MAINTAIN THE SPACE AT THE OCCUPIED COOLING TEMPERATURE SETPOINT.
THE SUPPLY AIR VALVE SHALL MODULATE TO MAINTAIN THE INDICATED AIRFLOW DIFFERENTIAL.
OCCUPIED COOLING SETBACK: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, AND THE SPACE TEMPERATURE
RISES ABOVE THE OCCUPIED SETBACK COOLING TEMPERATURE SETPOINT, COOLING CONTROL SHALL OVERRIDE AIR CHANGE RATE
CONTROL. THE GENERAL EXHAUST AIR VALVE SHALL MODULATE OPEN AS NEEDED TO MAINTAIN THE SPACE AT THE OCCUPIED SETBACK
COOLING TEMPERATURE SETPOINT. THE SUPPLY AIR VALVE SHALL MODULATE TO MAINTAIN THE INDICATED AIRFLOW DIFFERENTIAL.
UNOCCUPIED COOLING: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, AND THE SPACE TEMPERATURE RISES
ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, COOLING CONTROL SHALL OVERRIDE AIR CHANGE RATE CONTROL. THE
GENERAL EXHAUST AIR VALVE SHALL MODULATE OPEN AS NEEDED TO MAINTAIN THE SPACE AST THE UNOCCUPIED COOLING TEMPERATURE
SETPOINT. THE SUPPLY AIR VALVE SHALL MODULATE TO MAINTAIN THE INDICATED AIRFLOW DIFFERENTIAL.
SEQUENCE OF OPERATIONS
SCALE:1" = 1'-0"1 BUILDING AUTOMATION AND CONTROL SYSTEM DETAIL (B40B)
CONTROL AND ALARM POINTS SCHEDULE
LAB B40B
HARDWARE POINTS SOFTWARE POINTS
SHOW ON
GRAPHIC NOTESBI BO AI AO AV BV SCH TREND
ALARM
BACS EMCS DESCRIPTION
CV-105-RH, COIL VALVE POSITION COMMAND (%)X 5 DEG F DELTA T ACROSS COIL WITH VALVE COMMANDED CLOSED USE EXISTING POINT
EAV-B40B, AIRFLOW (CFM)X X X USE EXISTING POINT
EAV-B40B, AIRFLOW SETPOINT (CFM)USE EXISTING POINT
EAV-B40B, VALVE POSITION COMMAND (CFM)X X USE EXISTING POINT
SAV-B40B, AIRFLOW (CFM)X X X USE EXISTING POINT
SAV-B40B, AIRFLOW SETPOINT (CFM)X X USE EXISTING POINT
SAV-B40B, VALVE POSITION COMMAND (CFM)X X USE EXISTING POINT
1 08/04/20 ISSUE FOR DD REVIEW
2 09/01/20 ISSUE FOR 90% CD REVIEW
3 09/29/20 ISSUE FOR COORDINATED REVIEW
4 10/12/20 ISSUE FOR CONSTRUCTION
CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
M-501
12809855
SCHEDULES
S. BURKE
SLB
2024
OCTOBER 12, 2020
DUCT SPECIFICATIONS
SERVICE LOCATION
PRESSURE
CLASS
SEAL
CLASS
LEAKAGE
CLASS RECT
LEAKAGE
CLASS ROUND MATERIAL LINING
INSULATION
MIN R-VALUE
INSULATION
MATERIAL
INSULATION
FIELD JACKET
INSULATION VAPOR
RETARDER FINISH
SUPPLY: RECTANGULAR, EXPOSED, AHU - VAV 4" POS A 6 3 G90 GALVANIZED NONE R-6 B NONE YES PAINT
SUPPLY: RECTANGULAR, CONCEALED, AHU - VAV 4" POS A 6 3 G90 GALVANIZED NONE R-6 A NONE YES NONE
SUPPLY, RECTANGULAR, EXPOSED, TERMINAL UNIT - OUTLET 2" POS A 6 3 G90 GALVANIZED NONE R-6 B NONE YES PAINT
SUPPLY, ROUND, EXPOSED, TERMINAL UNIT - OUTLET 2" POS A 6 3 G90 GALVANIZED NONE R-6 D NONE YES PAINT
SUPPLY, RECTANGULAR, CONCEALED, TERMINAL UNIT - OUTLET 2" POS A 6 3 G90 GALVANIZED NONE R-6 A NONE YES NONE
SUPPLY, ROUND, CONCEALED, TERMINAL UNIT - OUTLET 2" POS A 6 3 G90 GALVANIZED NONE R-6 A NONE YES NONE
EXHAUST: LABORATORY HORIZONTAL MAINS 4" NEG A 6 3 G90 GALVANIZED NONE N/A N/A N/A N/A PAINT
EXHAUST: LABORATORY - ACCESSIBLE LOCATIONS AND RISERS 4" NEG A 6 3 G90 GALVANIZED NONE N/A N/A N/A N/A PAINT
SPECS:
1 ALL DUCTWORK AND ACCESSORIES SHALL BE FABRICATED AND INSTALLED IN COMPLIANCE WITH THE LATEST ISSUE OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE.
2 CONSTRUCT TEES, BENDS, AND ELBOWS WITH RADIUS OF NOT LESS THAN 1.0 TIMES THE WIDTH OF DUCT ON CENTER LINES.
3 WHERE RECTANGULAR ELBOWS ARE USED, PROVIDE AIR FOIL TYPE TURNING VANES.
4 INCREASE DUCT SIZES GRADUALLY, AND IN COMPLIANCE WITH FIGURE 4-7 OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE.
5 BRANCH CONNECTIONS SHALL BE MADE WITH A 45 DEGREE ENTRY. STRAIGHT TEES ARE NOT ACCEPTABLE.
6 SEALANTS AND GASKETS: SURFACE BURNING CHARACTERISTICS SHALL BE A MAXIMUM FLAME-SPREAD INDEX OF 25, AND MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED TO UL 723.
7 ALL MANUAL BALANCING DAMPERS SHALL BE PROVIDED WITH LOCKING HAND QUADRANT.
8 CONNECT DIFFUSERS TO SUPPLY DUCTS WITH MAXIMUM OF 36-INCHES OF FLEXIBLE DUCT CLAMPED OR STRAPPED IN PLACE.
9 PROVIDE FLEXIBLE CONNECTORS TO CONNECT DUCTS TO EQUIPMENT.
10 INSTALL VOLUME DAMPERS AT POINTS ON SUPPLY, RETURN, AND EXHAUST SYSTEMS WHERE BRANCHES EXTEND FROM LARGER DUCTS.
11 USE BLO-R-VAC PVC HOSE (McMASTER-CARR PART NO 5666K46) MEETING UL 94VO FOR FLAME RETARDANCE TO CONNECT ADA FUME HOODS WITH ADJUSTABLE BASES TO THE EXHAUST SYSTEM.
12 PAINT ALL DUCTWORK EXPOSED TO VIEW IN OCCUPIED AREAS TO MATCH SURROUNDING FINISH.
13 REMOVE SURFACE CONTAMINANTS AND DEPOSITS FROM DUCTWORK AND EQUIPMENT PRIOR TO TESTING AND BALANCING.
14 ALL INSULATION AND ADHESIVE SHALL HAVE A MAXIMUM FLAME-SPREAD INDEX OF 25 AND A MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84.
TYPE A INSULATION: MINERAL FIBERGLASS BLANKET, ASTM C553 TYPE I, ASTM C1136 TYPE I FACTORY APPLIED FSK JACKET, K-VALUE BETWEEN 0.22 -0.29 BTU-IN/HR-FT²-˚F @ 75 ˚F, 0.75 PCF
TYPE B INSULATION: MINERAL FIBERGLASS BOARD, ASTM C612 TYPE IA OR IB, ASTM C1136 TYPE I FACTORY APPLIED ASJ JACKET, K-VALUE BETWEEN 0.22 -0.29 BTU-IN/HR-FT²-˚F @ 75 ˚F, 3.0 PCF
TYPE D INSULATION: MINERAL FIBERGLASS, PREFORMED PIPE INSULATION, ASTM C 547, TYPE I, GRADE A, ASTM C1136 TYPE I FACTORY APPLIED ASJ JACKET, K-VALUE BETWEEN 0.22 -0.27 BTU-IN/HR-FT²-˚F @ 75 ˚F
AIRFLOW SCHEDULE - ROOMS WITHOUT FUME HOODS
ROOM # DESCRIPTION
ROOM AREA
(SF)
ROOM HEIGHT
(FT)VALVE VALVE SIZE
FACTORY
RANGE MAX
(CFM)
FACTORY
RANGE MIN
(CFM)
BACS SETPOINT, MAX HEATING
(CFM)
BACS SETPOINT, MAX
HEATING (ACH)
BACS SETPOINT,
OCCUPIED (CFM)
BACS SETPOINT, OCCUPIED
(ACH)
BACS SETPOINT,
UNOCCUPIED (CFM)
BACS SETPOINT, UNOCCUPIED
(ACH)
SUPPLY AIR
VALVE
SUPPLY
AIR
VALVE
SIZE
SUPPLY AIR, BACS
SETPOINT, OCCUPIED
(CFM)
SUPPLY AIR,
BACS
SETPOINT,
UNOCCUPIED
(CFM)
108 RESEACH LAB 380 9'
TB-35
(EXISTING TO
REMAIN)
10 - - - - 794 13.9 - -
TB-34
(EXISTING
TO REMAIN)
12 1150 72
B40 OFFICE 520 9' B40 6 - - 140 1.8 140 1.8 50 0.6
VSV-B40
(EXISTING
TO REMAIN)
4 140 60
B40B RESEACH LAB 1905 9' 8"
VEV-B40B
(EXISTING TO
REMAIN)
14 - - 2295 6.7 2295 6.7 1300 3.8
VSV-B40B
EXISTING
TO REMAIN
- 2050 1050
SPECS:
1ACCEPTABLE MANUFACTURERS: ANEMOSTAT, CARNES, KRUEGER, PRICE, TITUS
EG-2 B40B PRICE SDR-75-5 206 8
LINEAR
SLOT...
ALUMINU
M LAY-IN LINEAR
SLOT...WHITE
SD-1 B40B
YORK
(REUSE...
VARIABLE
VOLUME...103 -
LINEAR
SLOT...
ALUMINU
M
DUCT
MOUNT WHITE
MANF MODEL
TAG#LOCATION
SERVED
BOD AIRFLOW
(CFM)
NECK SIZE
(IN)TYPE MATERIA
L MOUNTING PATTER
N FINISH NOTES
REGISTER, GRILLE AND DIFFUSER SCHEDULE
1 08/04/20 ISSUE FOR DD REVIEW
2 09/01/20 ISSUE FOR 90% CD REVIEW
3 09/29/20 ISSUE FOR COORDINATED REVIEW
4 10/12/20 ISSUE FOR CONSTRUCTION
CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
E-001
12715689
GENERAL NOTES
AND SYMBOL
LEGENDS
E. REICHARD
ETR
2024
OCTOBER 12, 2020
LUMINAIRE SCHEDULE
TYPE DESCRIPTION MOUNTING SIZE MANUFACTURER CATALOG NO. VOLTAGE LAMPS WATTAGE FINISH
A-1 RECESSED VOLUMETRIC RECESSED 2X2 LITHONIA 2BLT2-RB-33LHE-ADP-MVOLT-EZ1-LP930 MVOLT LED 26.67 WHITE
GENERAL ELECTRICAL NOTES
1.0 ELECTRICAL SCHEMATICS INDICATED ON CONTRACT DOCUMENTS ARE
DIAGRAMMATIC. IT IS NOT THE INTENT TO SHOW EXACT OR MOST EFFICIENT
ROUTING. VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ON SITE. ANY
CONFLICTS BETWEEN CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALL
BE BROUGHT TO CORNELL'S PROJECT MANAGER FOR RESOLUTION BEFORE WORK
PROCEEDS.
2.0 ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOINING AREAS
FROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE AND DISPOSE OF
WASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISES FREE OF DEBRIS FROM
THE EXECUTION OF WORK. DELIVER A FINAL PRODUCT THAT IS CLEAN AND
OPERABLE.
3.0 FIRE STOP ELECTRICAL PENETRATIONS THROUGH FIRE RATED WALLS AND/OR
FLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTION OF THE
MATERIAL PENETRATED.
4.0 WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACT
DOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHOD OF
INSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FOR APPROVAL
PRIOR TO ORDERING ANY MATERIALS OR COMMENCING EXECUTION OF WORK.
5.0 GROUNDING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 250. PROVIDE
EQUIPMENT GROUND CONDUCTOR WITH EACH BRANCH CIRCUIT INDICATED ON
CONTRACT DOCUMENTS. EQUIPMENT GROUND CONDUCTOR SHALL BE ROUTED
WITH ASSOCIATED PHASE CONDUCTORS.
6.0 PROVIDE A NEW TYPED PANELBOARD DIRECTORY FOR EACH PANELBOARD. LABEL
ALL NEW DEVICE FACEPLATES WITH SOURCE AND CIRCUIT NUMBER. PROVIDE
PERMANENT LABEL ON SWITCHING DEVICES INDICATING EQUIPMENT SERVICE AND
INVENTORY NUMBERS. COORDINATE EQUIPMENT INVENTORY NUMBERS WITH
CORNELL UNIVERSITY'S MECHANICAL SHOP, 255-8667.
7.0 CIRCUITS RATED 20-AMP, 120 VOLT SHALL CONTAIN SEPARATE NEUTRAL
CONDUCTORS.
8.0 CONDUCTORS SHALL BE A MINIMUM OF 12AWG, STRANDED COPPER, 600VAC, 90
DEGREE C, TYPE THHN/THWN-2 FOR DRY AREAS AND XHHW/THWN-2 FOR WET
AREAS.
9.0 CONDUITS SHALL BE A MINIMUM OF 3/4 INCHES DIAMETER. CONDUITS SHALL BE
ELECTRICAL METALLIC TUBING (EMT) AND SURFACE MOUNTED UNLESS NOTED
OTHERWISE.
10.0 AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OF RESPECTIVE
PANELBOARD. SIZE AS INDICATED.
11.0 PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDE SUPPORT
HANGERS FOR CONDUIT AS NEEDED.
12.0 INSTALL RACEWAY SYSTEMS ENSURING PROPER ACCESS TO EQUIPMENT AND
DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND
REPAIR. RACEWAYS THAT ARE NOT INSTALLED WITH THIS REQUIREMENT IN MIND
SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES
ARE CORRECTED.
ELECTRICAL SCOPE OF WORK
1.0 PROVIDE POWER AND LIGHTING DESIGN FOR OLIN B40, B40B AND 108 LAB
RENOVATION.
ELECTRICAL LEGEND
LIGHTING LEGEND
MOTOR
1'x4' LUMINAIRE
HARDWIRED EQUIPMENT CONNECTION
P-1A
12
HOMERUN TO PANEL P-1A, CIRCUIT #12. FED
FROM 20A -1P BREAKER IS INTENDED UNLESS
NOTED OTHERWISE. RUN GREEN WIRE GROUND
FOR ALL CIRCUITS. PROVIDE ONE GROUND PER
CIRCUIT.
EMERGENCY POWER OFF (EPO)
GROUND ROD ELECTRODE
DUPLEX RECEPTACLE WITH GFCI PROTECTION
DUPLEX RECEPTACLE WITH AFCI PROTECTION
QUAD RECEPTACLE
LINETYPES LEGEND
SPECIAL RECEPTACLE5-30R
PANELBOARD
JUNCTION BOX
B = INSTALLED IN BASEBOARD
TR = INSTALLED IN WOOD TRIM/CASEWORK/WAINSCOTT
SR = SURFACE RACEWAY
WP = WEATHERPROOF
AC = AIR CONDITIONER
DUPLEX RECEPTACLE:
DOUBLE DUPLEX RECEPTACLE
MOTOR STARTER
J
2'x4' LUMINAIRE
CEILING MOUNTED LUMINAIRE
EM LIGHTING BATTERY UNIT
COMBO EXIT SIGN/EM LIGHTING BATTERY UNIT
SINGLE FACE, WALL MOUNT EXIT SIGN
DOUBLE FACE, WALL MOUNT EXIT SIGN
SINGLE FACE, CEILING MOUNT EXIT SIGN
DOUBLE FACE, CEILING MOUNT EXIT SIGN
LIGHT SWITCH:
SAFETY SWITCH (NON-FUSED)
SAFETY SWITCH (FUSED)
3 = 3-WAY SWITCH
4 = 4-WAY SWITCH
D = DIMMER SWITCH
O = WALL SWITCH OCCUPANCY SENSOR
V = WALL SWITCH VACANCY SENSOR
W = WIRELESS SWITCH
S = WIRELESS SCENE SWITCH
WIRELESS OCCUPANCY SENSOR
WIRELESS DAYLIGHT SENSOR
OS
DS
1'x2' LUMINAIRE
FIRE ALARM LEGEND
FIRE ALARM CONTROL PANEL
BATTERY CABINET
WATER FLOW SWITCH
MUXPAD
REMOTE ANNUNCIATOR
D = DUCT SMOKE DETECTOR
R = RELAY BASE
BR = BEAM RECEIVER
BT = BEAM TRANSMITTER
SB = SOUNDER BASE
SMOKE DETECTOR:
TAMPER SWITCH
AUDIBLE NOTIFICATION APPLIANCE
FACP
BATT
MUX
FAA
NAC PANELNAC
MANUAL PULL STATIONF
S X
F = FIXED TEMPERATURE
R = RATE OF RISE
R/F = COMBINATION RISE/FIXED TEMPERATURE
HEAT DETECTOR:
H X
CARBON MONOXIDE DETECTORCO
AM
F
XXcd
C
FS
F
S
XXcd
C
TS
ADDRESSABLE MODULE
XXcd = CANDELA
C = CEILING
COMBO A/V NOTIFICATION APPLIANCE:
XXcd = CANDELA
C = CEILING
VISUAL NOTIFICATION APPLIANCE:
SUPPRESSION SYSTEM
ELECTRICAL ABBREVIATIONS
AC AIR CONDITIONER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFI ARC FAULT INTERRUPTER
AMM ADDRESSABLE MONITOR MODULE
AOM ADDRESSABLE OUTPUT MODULE
ARB AUXILIARY RELAY BOARD
ATS AUTOMATIC TRANSFER SWITCH
B BASEBOARD
BKR BREAKER
C CONDUIT
CD CANDELA
CKT CIRCUIT
CR CONTROL RELAY
EC ELECTRICAL CONTRACTOR
EMT ELECTRICAL METALLIC TUBING
EPO EMERGENCY POWER OFF STATION
FAA FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FSD FIRE SMOKE DAMPER
GAA GENERATOR ALARM ANNUNCIATOR
GFI GROUND FAULT INTERRUPTER
GND GROUND
HP HORSEPOWER
KW KILOWATT
LC LIGHTING CONTACTOR
LFMC LIQUID TIGHT FLEXIBLE METALLIC CONDUIT
LTG LIGHTING
MCB MAIN CIRCUIT BREAKER
MLO MAIN LUG ONLY
MTS MANUAL TRANSFER SWITCH
NAC NOTIFICATION APPLIANCE CIRCUIT
NIC NOT IN CONTRACT
OE OVERHEAD ELECTRIC
PC PHOTOCELL
PM PLUGMOLD
PP POWER PANEL
PVC POLYVINYL CHLORIDE CONDUIT
RGS RIGID GALVANIZED STEEL CONDUIT
SR SURFACE RACEWAY
ST SHUNT TRIP
TM THERMAL MAGNETIC
TR TRIM/CASEWORK/WAINSCOTT
TSP TWISTED SHIELDED PAIR
TYP TYPICAL
UE UNDERGROUND ELECTRIC
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLTS
VA VOLT AMPS
WP WATERPROOF
UNDERGROUND ELECTRICU
E
UNDERGROUND LIGHTINGUL
OVERHEAD ELECTRICO
E
TO BE PROVIDED
DEMOLITION / TO BE RELOCATED
EXISTING TO REMAIN
UNDERGROUND TELCOU
C
MOUNTING HEIGHTS
CARD READER 48" TOP OF BOX
LIGHT SWITCH 48" TOP OF BOX
RECEPTACLE 18" TOP OF BOX
DATA OUTLET 18" TOP OF BOX
TV OUTLET 84" TOP OF BOX
PHONE OUTLET 48" TOP OF BOX
SAFETY SWITCH 60" CENTERLINE OF HANDLE
MOTOR STARTER 60" CENTERLINE OF HANDLE
PANELBOARD 72" TOP OF PANELBOARD
MANUAL PULL STATION 48" OPERABLE HANDLE
NOTIFICATION APPLIANCE 80" BOTTOM OF LENS
DOOR HOLD OPEN COORDINATE IN FIELD
EM BATTERY UNIT 96" BOTTOM OF UNIT
EM REMOTE UNIT 102" BOTTOM OF UNIT
EXIT SIGN 96" BOTTOM OF UNIT
LIGHT POLE WITH LED LUMINAIRES, REFER TO
PLANS FOR NUMBER AND CONFIGURATION OF
HEADS
GENERAL ELECTRICAL DEMOLITION NOTES
1.0 ELECTRICAL EQUIPMENT SHOWN DASHED ON DEMOLITION DRAWINGS, INCLUDING
ASSOCIATED ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS, AND OTHER
APPURTENANCES NOT SHOWN, SHALL BE DISCONNECTED AND REMOVED.
REMOVE ASSOCIATED BRANCH CIRCUITRY TO SOURCE, UNLESS NOTED
OTHERWISE.
2.0 EXISTING RACEWAYS AND DEVICE BACKBOXES NOT INTERFERRING WITH NEW
WORK SHALL BE REUSED WHERE POSSIBLE.
3.0 PROVIDE JUNCTION BOXES, RACEWAYS, AND WIRING TO MODIFY/EXTEND EXISTING
SYSTEMS AND CIRCUITS FED DOWNSTREAM OF ELECTRICAL EQUIPMENT SHOWN
TO BE DEMOLISHED.
4.0 CUT DEMOLISHED CONDUITS INSTALLED THRU WALLS AND FLOORS FLUSH WITH
THE SURFACE AND PATCH PENETRATIONS (FIRESTOP IF LOCATED ON A FIRE
RATED SURFACE). PATCH AND PAINT SURFACES IN EXPOSED AREAS TO MATCH
SURROUNDING MATERIALS, FINISHES, AND COLORS.
5.0 PROVIDE BLANK COVERPLATES ON UNUSED BACKBOXES REMAINING FROM
DEMOLITION NOT SPECIFIED TO BE INFILLED.
6.0 EXISTING EQUIPMENT SHOWN TO REMAIN SHALL BE PROTECTED DURING
CONSTRUCTION.
1 08/04/20 ISSUE FOR DD REVIEW
2 09/01/20 ISSUE FOR 90% REVIEW
3 09/29/20 ISSUE FOR COORDINATED REVIEW
4 10/12/20 ISSUE FOR CONSTRUCTION
F
F
F
F
PANEL SP4
PANEL SP3
PANEL SP2
PANEL SP1
EM
EM
SP3/6
SP2/2,4
LEPPB/4,8
SP2/1
SP1/26
B40B
B40
B40C B00CD
B40A
B00UH
B00JC
1
2
34
4
4
5
PP2/22 PP2/24
PP2
10
11
DH AM
DH
PANEL LAB-BC
13
PANEL SP-4
PANEL SP-3
PANEL SP-2
PANEL SP-1
B40B
B40
B40C B00CD
B40A
B00UH
B00JC
1 2
3
EM RECEPTACLES
5
EM
EM
30A208V20A208VEXISTING RECEPTACLE
FOR NEW COMPRESSOR 333333333 3B40B
B40
B40C B00CD
B40A
B00UH
B00JC
4
4
4
4
4
4
4 4 33DDB40B
B40
B40C B00CD
B40A
B00UH
B00JC
A-1 A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1A-1
A-1
A-1 A-1
A-1A-1A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1 A-1 A-1 A-1
A-1
A-1 A-1
A-1
A-1
7
6
67
7
6
6
6
6DDOS
OS
OSOS
A-1
A-1
8
8
8
8
8
9
12
12
12 CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
E-101
12715689
ELECTRICAL
DEMOLITION &
RENOVATION
PLANS
E. REICHARD
ETR
2024
OCTOBER 12, 2020
#
0' 4' 8'16'
SCALE: 1/8"=1'-0"
E-101 KEYED DEMOLITION NOTES
1 DISCONNECT AND REMOVE THE 250V, NEMA L6-20R TWIST LOCK RECEPTACLE.
REMOVE CONDUIT AND CONDUCTORS BACK TO SOURCE.
2 PROVIDE KNOCKOUT COVERS FOR PANEL SP-2 TO COVER EXISTING KNOCKOUTS
AND KNOCKOUTS FROM REMOVALS.
3 DISCONNECT AND REMOVE RECEPTACLES ALONG THE EAST WALL BETWEEN THE
DOORS. REMOVE CONDUCTORS BACK TO SOURCE AND LABEL SPARE.
4 DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. REMOVE CONDUIT AND
CONDUCTORS BETWEEN FIXTURES. CONDUIT AND CONDUCTORS FOR EXISTING
SWITCHES TO REMAIN FOR REUSE WITH NEW LIGHT FIXTURES.
5 DISCONNECT AND REMOVE THE EXISTING EMERGENCY RECEPTACLES ON EAST
WALL. REMOVE CONDUIT TO TOP OF ROOM. INSTALL JUNCTION BOX AND SAVE
CONDUCTORS FOR REUSE.
#E-101 KEYED RENOVATION NOTES
1 PROVIDE SQUARE D, QO, 120V, SINGLE POLE, 10KA, 20A BREAKER IN PANEL SP-1
FOR RECEPTACLE CIRCUIT.
2 PROVIDE THREE SQUARE D, QO, 120V, SINGLE POLE, 10KA, 20A BREAKERS IN PANEL
SP-2 FOR RECEPTACLE CIRCUITS.
3 PROVIDE SQUARE D, QO, 120V, SINGLE POLE, 10KA, 20A BREAKER IN PANEL SP-3
FOR RECEPTACLE CIRCUIT.
4 PROVIDE TWO NEMA 5-20R RECEPTACLES ON OVERHEAD UTILITY POST ABOVE
TABLE. PROVIDE 2-#12 AND 1-#12 GND IN ¾” EMT FROM PANEL TO SOLID CHANNEL
1-5/8” TYPE STRUT WITH CHANNEL COVER FOR USE AS RACEWAY. MOUNT STRUT
VERTICALLY AND PROVIDE RECEPTACLES ALONG FACE OF STRUT RACEWAY, ONE
ON EACH SIDE.
5 PROVIDE RECEPTACLES 6” ABOVE COUNTERTOP IN ALUMINUM DIVIDED 3300
RACEWAY TO SPLIT NORMAL AND BACKUP/EM CONDUCTORS. PROVIDE 2-#12 AND
1-#12 GND IN ¾” EMT FROM PANEL TO LOCATION ABOVE CEILING NEAR
COUNTERTOP AND TRANSITION TO THE SURFACE RACEWAY. PROVIDE 2-#12 AND
1-#12 GND ¾” EMT (SEPARATE FROM NORMAL POWER CONDUCTORS) FROM
JUNCTION BOX WITH SAVED CONDUCTORS FOR EMERGENCY CIRCUITS (LEPPB 4,8)
TO LOCATION ABOVE CEILING NEAR COUNTERTOP AND TRANSITION TO THE
SURFACE RACEWAY.
6 PROVIDE NEW LIGHT FIXTURE IN LOCATION INDICATED. PROVIDE 2-#12 AND 1-#12
GND IN MC CABLE BETWEEN FIXTURES AND TO POWER PACK FOR CONTROL.
RECONNECT TO LINE SIDE CONDUCTORS SAVED FROM REMOVALS FOR POWER.
PROVIDE SENSOR SWITCH CM9 OCCUPANCY SENSORS (OR EQUAL) IN LOCATIONS
INDICATED WITH A SENSOR SWITCH PP20 (OR EQUAL) POWER PACK MOUNTED IN
JUNCTION BOX ABOVE CEILING. PROVIDE SENSOR SWITCH SPODMDSAWH DIMMER
SWITCH (OR EQUAL) IN EXISTING 4 GANG BOX AT DOOR SAVED FROM REMOVALS.
PROVIDE LOW VOLTAGE WIRING FROM OCCUPANCY SENSOR TO SWITCH, FROM
POWER PACK TO SWITCH AND FROM LED DRIVER TO SWITCH. REFER TO WIRING
DIAGRAM DETAIL 2 ON DWG E-501 FOR ADDITIONAL INFORMATION.
7 PROVIDE NEW LIGHT FIXTURE IN LOCATION INDICATED. PROVIDE 2-#12 AND 1-#12
GND IN MC CABLE BETWEEN FIXTURES AND TO POWER PACK FOR CONTROL.
RECONNECT TO LINE SIDE CONDUCTORS SAVED FROM REMOVALS FOR POWER.
PROVIDE A SENSOR SWITCH PP20 (OR EQUAL) POWER PACK MOUNTED IN
JUNCTION BOX ABOVE CEILING. PROVIDE SENSOR SWITCH SPODMDSAWH DIMMER
SWITCH (OR EQUAL) IN EXISTING SINGLE GANG BOX SAVED FROM REMOVALS.
PROVIDE LOW VOLTAGE WIRING FROM POWER PACK TO SWITCH AND FROM LED
DRIVER TO SWITCH. REFER TO WIRING DIAGRAM DETAIL 1 ON DWG E-501 FOR
ADDITIONAL INFORMATION.
8 PROVIDE BLANK COVER PLATE ON EXISTING SWITCH BOX.
9 PROVIDE 4 GANG WALL PLATE WITH 2 BLANKS FOR NEW DIMMER SWITCHES AT
DOOR. PROVIDE 4 GANG ALL PLATE WITH 4 BLANKS FOR BOTTOM BOX AT DOOR.
10 PROVIDE RECEPTACLES IN EXISTING SURFACE RACEWAY. PROVIDE 2-#12 AND
1-#12 GND IN EXISTING RACEWAY AND CONNECT TO EXISTING CIRCUITS AS NOTED.
11 PROVIDE 60W, 120VAC INPUT, 24VDC OUTPUT POWER SUPPLY FOR SYRINGE PUMP.
COORDINATE FINAL LOCATION WITH LAB USERS.
12 PROVIDE NEW EMERGENCY LIGHT FIXTURE IN LOCATION INDICATED. FIXUTRE IS TO
BE WIRED DIRECTLTY TO EMERGENCY CIRCUIT AND ALWAYS ON. PROVIDE 2-#12
AND 1-#12 GND IN MC CABLE FROM NEW EMERGENCY FIXTURES TO EXISTING
EMERGENCY LIGHT IN HALLWAY.
13 PROVIDE 2-#12 AND 1-#12 IN MC FROM PANEL LAB-BC CIRCUIT #2, 20 AMP SPARE
BREAKER TO MAGNETIC DOOR HOLDERS VIA FIRE ALARM RELAY MODULE
NORMALLY CLOSED CONTACTS. DOOR HOLDERS PROVIDED BY GC. SOUTH DOOR
HOLDER IS MOUNTED TO WALL, NORTH DOOR HOLDER IS ON FLOOR. PROVIDE
JUNCTION BOX AND SURFACE RACEWAY FROM WALL TO NORTH DOOR HOLDER ON
FLOOR. SOUTH DOOR HOLDER IS MOUNTED TO WALL. PAINT BOX AND SURFACE
RACEWAY TO MATCH WALL AND FLOOR. PROVIDE AOM-2RF FIRE ALARM RELAY
CONTROL MODULE ABOVE CEILING IN 4”X4” JUNCTION BOX AND CONNECT TO SLC
WITH 2-#14 IN ½” EMT.
SCALE:1/8" = 1'-0"2 BASEMENT POWER, DATA & FIRE ALARM RENOVATION
SCALE:1/8" = 1'-0"1 BASEMENT POWER, DATA & FIRE ALARM DEMOLITION
SCALE:3/16" = 1'-0"5 1ST FLOOR EXISTING PLAN
SCALE:1/8" = 1'-0"3 BASEMENT LIGHTING DEMOLITION
SCALE:1/8" = 1'-0"4 BASEMENT LIGHTING RENOVATION
1 08/04/20 ISSUE FOR DD REVIEW
2 09/01/20 ISSUE FOR 90% REVIEW
3 09/29/20 ISSUE FOR COORDINATED REVIEW
4 10/12/20 ISSUE FOR CONSTRUCTION
ON/OFF
WH
GRY
VIO
REDBLK
WH/BLU
RED
BLK
VIO
LINE N
WH
BLK/OR
BLU
BLU
PP20
POWERPACK
DIMMER
SWITCH
LED
DRIVER
2-#18 IN MC3-#18 IN MC
ON/OFF
WH
GRY
VIO
REDBLK
WH/BLU
RED
BLK
WH
VIO
WH RED
BLK
LINE N
WH
BLK/OR
BLU
BLU
PP20
POWERPACK
OCCUPANCY
SENSOR
DIMMER
SWITCH
LED
DRIVER
2-#18 IN MC3-#18 IN MC
3-#18 IN MC CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
E-501
12715689
SCHEDULES &
DETAILS
E. REICHARD
JD
2024
OCTOBER 12, 2020
TOTAL AMPS:0 A 0 A 0 A
TOTAL LOAD:0 VA 0 VA 0 VA
29 30
27 28
25 AIR COND. RM 128 20 1 0 0 1 20 REC EX OPTICS TABLE 26
23 -- -- --0 0 1 20 DEDICATED LSR REC W. WALL 24
21 -- -- -- 0 0 -- -- -- 22
19 BAKEOUT OVENS ZASTAR 20 3 0 0 2 20 EXISTING LOAD 20
17 H AREA 6 20 1 0 0 -- -- -- 18
15 F AREA 5 20 1 0 0 2 20 208 REC AREA 1 16
13 E AREA 5 20 1 0 0 1 20 I AREA 7 14
11 L AREA 8 20 1 0 0 1 20 J AREA 7 12
9 K AREA 8 20 1 0 0 1 20 G AREA 6 10
7 M AREA 8 20 1 0 0 1 20 D AREA 1 8
5 D AREA 4 20 1 0 0 1 20 C AREA A 6
3 P AREA 4 20 1 0 0 1 20 B AREA 1-2 4
1 N AREA 2 20 1 0 0 1 20 A AREA 1-2 2
CKT DESCRIPTION TRIP POLES A B C POLES TRIP DESCRIPTION CKT
ENCLOSURE:Type 1
MOUNTING:Surface WIRES:4 MAINS RATING:100 A
FED FROM:PHASE:3 MAINS TYPE:MLO
LOCATION:VOLTS:208Y/120V AIC RATING:10,000 AMPS
PANEL SP-1
TOTAL AMPS:0 A 0 A 0 A
TOTAL LOAD:0 VA 0 VA 0 VA
11 -- -- --0 0 -- -- -- 12
9 -- -- -- 0 0 -- -- -- 10
7 NO. 2 50 3 0 0 3 50 NO. 1 8
5 -- -- --0 0 1 15 EXISTING LOAD 6
3 LASER POWER 208V 15 2 0 0 1 20 REC NEWPORT TABLE 4
1 REC EAST COUNTER TOP 20 1 0 0 1 20 REC NEWPORT TABLE 2
CKT DESCRIPTION TRIP POLES A B C POLES TRIP DESCRIPTION CKT
ENCLOSURE:Type 1
MOUNTING:Surface WIRES:4 MAINS RATING:100 A
FED FROM:PHASE:3 MAINS TYPE:MLO
LOCATION:VOLTS:208Y/120V AIC RATING:10,000 AMPS
PANEL SP-2
TOTAL AMPS:0 A 0 A 0 A
TOTAL LOAD:0 VA 0 VA 0 VA
11 EXISTING LOAD 20 1 0 0 -- -- -- 12
9 EXISTING LOAD 20 1 0 0 -- -- -- 10
7 -- -- -- 0 0 3 20 EXISTING LOAD 8
5 EXISTING LOAD 30 2 0 6
3 EX OPTICS TABLE 20 1 0 4
1 2
CKT DESCRIPTION TRIP POLES A B C POLES TRIP DESCRIPTION CKT
ENCLOSURE:Type 1
MOUNTING:Surface WIRES:4 MAINS RATING:100 A
FED FROM:PHASE:3 MAINS TYPE:MLO
LOCATION:VOLTS:208Y/120V AIC RATING:10,000 AMPS
PANEL SP-3
TOTAL AMPS:0 A 0 A 0 A
TOTAL LOAD:0 VA 0 VA 0 VA
11 -- -- --0 0 1 30 EXISTING LOAD 12
9 220V REC SOUTH EAST WALL 15 2 0 0 -- -- -- 10
7 -- -- -- 0 0 2 15 208V REC SOUTH WALL 8
5 220V REC SOUTH WEST WALL 20 2 0 0 -- -- -- 6
3 -- -- -- 0 0 2 30 220V REC SOUTH EAST WALL 4
1 220V REC WEST WALL 20 2 0 2
CKT DESCRIPTION TRIP POLES A B C POLES TRIP DESCRIPTION CKT
ENCLOSURE:Type 1
MOUNTING:Surface WIRES:4 MAINS RATING:100 A
FED FROM:PHASE:3 MAINS TYPE:MLO
LOCATION:VOLTS:208Y/120V AIC RATING:10,000 AMPS
PANEL SP-4
NOTES: NEW BREAKERS AND DESIGNATIONS SHOWN IN BOLD.
NOTES: NEW BREAKERS AND DESIGNATIONS SHOWN IN BOLD.NOTES: NEW BREAKERS AND DESIGNATIONS SHOWN IN BOLD.
NOTES: NEW BREAKERS AND DESIGNATIONS SHOWN IN BOLD.
NOT TO SCALE1LIGHTING CONTOROL WIRING DIAGRAM
NOT TO SCALE2LIGHTING CONTROL WIRING DIAGRAM WITH OCCUPANCY SENSOR
NOTES: ADDITIONAL POWERPACK AND WIRING FOR HVAC CONTROL TO BE PROVIDED AND CONNECTED BY OTHERS. COORDINATE
WITH HVAC CONTRACTOR.
1 08/04/20 ISSUE FOR DD REVIEW
2 09/01/20 ISSUE FOR 90% REVIEW
3 09/29/20 ISSUE FOR COORDINATED REVIEW
4 10/12/20 ISSUE FOR CONSTRUCTION
CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
P-001
12809855
GENERAL NOTES
AND SYMBOL
LEGENDS
T. FISHER
TRF
2024
OCTOBER 12, 2020
PLUMBING SUBMITTAL SCHEDULE
SECTION REQUIRED TITLE
220523 GENERAL DUTY VALVES FOR PLUMBING PIPING PRODUCT DATA
220529 HANGERS & SUPPORTS FOR PLUMBING PRODUCT DATA
220553 ID FOR PIPING AND EQUIPMENT PRODUCT DATA
220719 PLUMBING PIPING INSULATION PRODUCT DATA
221116 DOMESTIC WATER PIPING PRODUCT DATA,TESTING
224500 LABORATORY PLUMBING FIXTURES AND TRIM PRODUCT DATA
224500 EMERGENCY PLUMBING FIXTURES PRODUCT DATA
226113 LABORATORY COMPRESSED AIR PIPING PRODUCT DATA,TESTING
226653 LAB WASTE & LAB VENT PIPING PRODUCT DATA,TESTING
PLUMBING SCOPE OF WORK
1.0 B40 - PROVIDE COMPRESSED AIR SERVICE CONNECTIONS AT GENERAL POINTS OF
USE AND SUPPLY FOR OPTICS TABLE ISOLATORS.
2.0 B40 - PROVIDE ADA COMPLIANT FAUCET, EYEWASH, PIPING AND ACCESSORIES FOR
CASEWORK LAB SINK.
3.0 SELECTIVE DEMOLITION OF EXISTING ABANDONED PIPING.
4.0 EXISTING FIRE PROTECTION SYSTEMS ARE EXISTING TO REMAIN. EXISTING SPACE
CONSTRAINTS AND OBSTRUCTIONS ARE TO BE SIMILAR TO EXISTING CONDITIONS.
PLUMBING FIXTURE SCHEDULE & SPEC
TAG COMPONENTS MANUFACTURER MODEL DESCRIPTION MATERIAL FINISH / COLOR COLD WATER HOT WATER TEPID WATER WASTE / SANITARY VENT STANDARDS
F1-B40B LAB SINK FAUCET WATER SAVER L412VB-BH MIXING, GOOSENECK BRASS CHROME PLATED 1/2" 1/2"ADA COMPLIANT
DRAIN AND TRAP ORION BLUELINE FRPP NH DRUM TRAP POLYPROPYLENE STANDARD 1-1/2" 1-1/2" NO HUB MECHANICAL JOINT FITTINGS
SUPPLY/STOPS T&S BRASS B-1310 ANGLE KEY STOP BRASS STANDARD 1/2" 1/2"1/2" INLET, OUTLET SHALL MATCH FAUCET CONNECTION SIZE
EW-B40 EMERGENCY EYEWASH BRADLEY S19274HDB DECK MOUNTED , SWING DOWN BRASS CHROME PLATED 1/2" 1/2"ADA COMPLIANT
PLUMBING PIPING SCHEDULE AND SPECIFICATIONS
PIPE SERVICE ABBREVIATION MATERIAL FITTINGS JOINT
INSULATION
THICKNESS
(IN)
CONDUCTIVITY
(BTU-IN/HR-FT^2-DEGF)
MEAN TEMP
(DEG F)MATERIAL
DOMESTIC COLD WATER DCW ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER, LEAD FREE 1 0.22-0.27 75 TYPE A
DOMESTIC HOT WATER DHW ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER, LEAD FREE 1 0.22-0.27 75 TYPE A
LAB WASTE & VENT LW/LV ASTM D4101 ASTM D635 POLYPROPYLENE, SCH 40 ASTM D4101 POLYPROPYLENE MECHANICAL N/A N/A N/A N/A
COMPRESSED AIR CA ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER, LEAD FREE N/A N/A N/A N/A
PIPING ACCESSORIES SCHEDULE AND SPECIFICATIONS
TAG DEVICE
BOD
MANUFACTURER MODEL CAPACITY SPECIFICATIONS
MV-B40B MIXING VALVE BRADLEY S19-2000 1.5 GPM MINIMUM FLOW ROUGH BRASS, ANSI Z358.1 COMPLIANT, ASSE 1071 CERTIFIED, FACTORY SETPOINT 85 DEG F.
PRV1-B40B PRESSURE REGULATING ASSEMBLY WATERSAVER L2873-366V-758WS 300 PSIG WOG VERTICAL ASSEMBLY, BRASS BODY WITH NEOPRENE DIAPHRAGM, 0-125 PSIG OUTLET RANGE, REMOVABLE QUICK CONNECT FITTING.
V-1 SHUT-OFF BALL VALVE(WATER/AIR SERVICE) WATTS B6000-SS 300 PSIG WOG MSS SP-110, 2-PIECE, STANDARD PORT, BRONZE BODY, 316 SS BALL & STEM, PTFE OR TFE SEAT
PLUMBING GENERAL NOTES
1.0 DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT
OF SYSTEMS AND WORK INCLUDED IN THE CONTRACT. CONTRACTOR SHALL
FIELD VERIFY ALL DIMENSIONS. IF DIMENSIONS OR CONDITIONS ARE FOUND
TO BE IN CONFLICT WITH THE DRAWINGS, THE CONTRACTOR SHALL
IMMEDIATELY REFER THE CONFLICT TO THE ENGINEER.
2.0 UTILITY SHUTDOWNS: SHUTDOWN OF ANY BUILDING UTILITY SYSTEM SHALL
BE COORDINATED WITH CUSTOMER SERVICE AT PH: 607-255-5322. THE
CONTRACTOR SHALL BEAR THE COST OF THE UTILITY SHUTDOWN.
SCHEDULE WORK TEN DAYS IN ADVANCE AND NOTIFY THE OWNER'S
REPRESENTATIVE TO COORDINATE BUILDING FUNCTIONS WITH THE
BUILDING COORDINATOR.
3.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE
WORK OF OTHER TRADES (EG ELECTRICAL, MECHANICAL). ALTHOUGH NOT
NECESSARILY SHOWN ON DRAWINGS, WORK IS REQUIRED IN THESE AREAS
CONSISTING OF REMOVAL / REPLACEMENT OF CEILINGS, WALLS, FINISHES,
PAVEMENT AND OTHER CONSTRUCTION AS NECESSARY TO PERFORM WORK
AND RESTORE THESE SPACES OR AREAS TO ORIGINAL CONDITION.
4.0 ALL PENETRATIONS THROUGH FULL HEIGHT WALLS ARE TO BE FIRESTOPPED
IN ACCORDANCE WITH UL STANDARDS. ALL GAPS AND JOINTS AT RATED
FLOORS, ROOFS AND WALLS ARE TO BE FIRE AND SMOKE STOPPED. CAPS
AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR
ROOF DECK, WALL TO BEAMS, AND CONTROL OR EXPANSION JOINTS.
FIRESTOPPING INCLUDES BOTH FORM OR PACKING MATERIAL AND THE FILL,
VOID OR CAVITY MATERIAL.
5.0 INSTALL EQUIPMENT TO ENSURE PROPER ACCESS TO CONTROL DEVICES
AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND
REPAIR. EQUIPMENT THAT IS NOT INSTALLED WITH THIS REQUIREMENT IN
MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL
DEFICIENCIES ARE CORRECTED.
6.0 ALL SYSTEM TESTING SHALL BE CONDUCTED PRIOR TO INSULATION,
FIREPROOFING, AND ENCLOSURE IN SHAFTS. ANY RESTORATION WORK
REQUIRED AS A RESULT OF DISTURBING FINISHES OR STRUCTURE IN ORDER
TO ACCESS SYSTEMS REQUIRING REPAIR SHALL BE AT NO COST TO THE
UNIVERSITY.
7.0 VERIFY FINAL EQUIPMENT/FIXTURE LOCATIONS FOR ROUGHING-IN.
8.0 ANY FIRESTOPPING DISTURBED DURING THE COURSE OF WORK SHALL BE
REPAIRED TO MAINTAIN A 2-HOUR FIRE RATING.
9.0 THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR, MATERIALS, AND
EQUIPMENT NECESSARY TO FORM A COMPLETE, FUNCTIONING SYSTEM. ITEMS
NOT SPECIFICALLY MENTIONED, BUT WHICH ARE INHERENTLY NECESSARY TO
MAKE A COMPLETE WORKING INSTALLATION SHALL BE PROVIDED.
1 08/04/20 ISSUE FOR DD REVIEW
2 09/01/20 ISSUE FOR 90% CD REVIEW
3 09/29/20 ISSUE FOR COORDINATED REVIEW
4 10/12/20 ISSUE FOR CONSTRUCTION
SPECIFICATIONS:
1. SOLDER FILLER METALS: ASTM B32, LEAD-FREE ALLOYS. INCLUDE WATER FLUSHABLE FLUX ACCORDING TO ASTM B813.
2. INSTALL PLUMBING SYSTEMS TO FACILITATE SERVICE, MAINTENANCE AND REPAIR OR REPLACEMENT OF COMPONENTS.
3. ALL WASTE PIPING SHALL BE PITCHED AT 1/8" PER FOOT. ALL SUPPLY PIPING SHALL BE PITCHED BACK TOWARDS CONNECTION TO THE ROOM ENTRANCE.
4. PROVIDE VAPOR RETARDER ON PIPING INSULATION SYSTEMS CARRYING FLUIDS WITH AN OPERATING TEMPERATURE LOWER THAN 60 DEGREES F.
5. POLYPROPYLENE PIPING SHALL BE FLAME RETARDANT.
6. ALL PIPING AND INSULATION SYSTEM EXPOSED TO VIEW SHALL BE PAINTED TO MATCH SURROUNDING SURFACES.
7. MAINTAIN INDICATED FIRE RATING OF WALLS, PARITIONS, CEILINGS, AND FLOORS AT PIPE PENETRATIONS. SEAL PIPE PENETRATIONS WITH FIRESTOP MATERIALS.
8. DO NOT ENCLOSE, COVER OR PUT PLUMBING PIPING SYSTEMS INTO OPERATION UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE AUTHORITIES HAVING JURISDICTION.
9. LEAVE NEW, ALTERED, EXTENDED, OR REPLACED DOMESTIC WATER PIPING UNCOVERED AND UNCONCEALED UNTIL IT HAS BEEN TESTED. EXPOSE WORK THAT WAS COVERED OR CONCEALED BEFORE IT WAS TESTED.
10. PROVIDE PIPE LABLES AND DIRECTIONAL ARROWS ON ALL NEW PIPING SYSTEMS. LABELS SHALL BE PRINTED PLASTIC WITH CONTACT-TYPE, PERMANENT ADHESIVE BACKING. LETTERS SHALL BE 1/4-INCH IF VIEWING DISTANCE IS LESS THAN 24 INCHES, 1/2-
INCH FOR VIEWING DISTANCES UP TO 72 INCHES, AND PROPORTIONATELY LARGER LETTERING FOR GREATER VIEWING DISTANCES.
11. ALL INSULATION AND ADHESIVE SHALL HAVE A MAXIMUM FLAME-SPREAD INDEX OF 25 AND A MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84.
12. TESTING OF DOMESTIC WATER PIPING:
CAP AND SUBJECT DOMESTIC WATER PIPING TO STATIC WATER PRESSURE OF 50 PSIG ABOVE OPERATING PRESSURE, WITHOUT EXCEEDING PRESSURE RATING OF PIPING SYSTEM MATERIALS
ISOLATE TEST SOURCE AND ALLOW TO STAND FOR FOUR HOURS. LEAKS AND LOSS IN TEST PRESSURE CONSTITUTE DEFECTS THAT MUST BE REPAIRED
REPAIR LEAKS AND DEFECTS WITH NEW MATERIALS AND RETEST PIPING UNTIL SATISFACTORY RESULTS ARE OBTAINED.
13. TESTING OF LAB WASTE AND VENT PIPING:
CAP AND SUBJECT DOMESTIC WASTE AND VENT PIPING TO STATIC WATER PRESSURE OF 10 FEET HEAD PRESSURE ABOVE HIGHEST POINT OF SYSTEM UNDERGOING TEST
ISOLATE TEST SOURCE AND ALLOW TO STAND UNTIL SYSTEM CAN BE VISUALLY INSPECTED BY AUTHORITY HAVING JURISDICTION. LEAKS CONSTITUTE DEFECTS THAT MUST BE REPAIRED
REPAIR LEAKS AND DEFECTS WITH NEW MATERIALS AND RETEST PIPING UNTIL SATISFACTORY RESULTS ARE OBTAINED.
SPECIFICATIONS:
1. PROVIDE PRESSURE GAUGES AT DISCHARGE OF EACH PRESSURE REDUCING VALVE AND WHERE INDICATED.
1
3/4" CA
1 1/2" CA1 1/2" CACA DRYER (E)
FD (E)
1
B40B
Room
B40
Room
B00CD
RoomB40C
Room
B40A
Room
B00UH
Room
B00UM
Room
B00JC
Room
B00UF
Room
2 3
1-1/2" CAPPED PIPE
STUB ABOVE
FLOOR (E)
CA DRYER AND
FILTERS (E)
1 1/2" CA1 1/2" CA3/4" CA
1
3/4" CA
1/2" CA
2
7
3
CA
B40B
Room
B40A
Room
B00UH
Room
B00CD
Room
B40
Room
B00JC
Room
B00UF
Room
B00UM
RoomP-101
4
PRV1-B40
PRV1-B40
CA
CA
5
P-101
3/4" CA53/4" CA1/2" CA
1/2" CA
E5
E4.1
E4
OPTICS
TABLE
OPTICS
TABLE
OPTICS
TABLE
9
F1-B40B
EW-B40B
MV-B40B
EYEWASH
LAB SINK FAUCET
MIXING VALVE
1-1/2" LW
1-1/2" LV
1/2" CW
1/2" HW
WITHIN BASE CABINET CHASE
6
PRV1-B40B 8 CA
1/2" CA 4
RHEOMETER
(OWNER
PROVIDED)
E1 E1.2 E1.3
1ST FLOOR
0' -0"
PLATFORM
-4' -6"
1ST FLOOR
0' -0"
OPTICAL TABLE (E)
V-1
PRV1-B4021/2" CAMOUNT PIPING TO
UNISTRUT POLE DROP CEILING (E)
PROVIDE SPLIT-RING
ESCUTCHEON AT
PIPING PENETRATIONS
THROUGH CEILING
TERMINATE PIPING
SERVICE WITH
SWAGELOCK 1/4"
FITTING FOR
CONNECTION BY
OTHERS
V-1
CORN E LL U N I V
E
R
SI
TYFOU
N
D E D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
113 HO PLAZA
ITHACA, NEW YORK 14850
OLIN HALL B40B
LAB RENOVATION
P-101
12809855
PARTIAL
BASEMENT AND
FIRST FLOOR
PLUMBING
PLANS
T. FISHER
TRF
2024
OCTOBER 12, 2020
SCALE:1/8" = 1'-0"1 PARTIAL BASEMENT PLUMBING DEMOLITION PLAN
SCALE:1/8" = 1'-0"2 PARTIAL BASEMENT PLUMBING CONSTRUCTION PLAN
P-101 KEYED DEMOLITION NOTES
1 DISCONNECT AND REMOVE PORTION OF EXPOSED COMPRESSED AIR PIPING,
ACCESSORIES AND VALVES BACK TO ABOVE CEILING. REFER TO 2/P-101 FOR
RECONNECTION.
2 DISCONNECT DOMESTIC COLD WATER AND HOT WATER SERVING EXISTING LAB
SINK. PREPARE PIPING TO SERVE ADA LAB SINK IN LAB B40. CUT AND PATCH WALL
AS REQUIRED TO ACCESS PIPING. PATCH WALL TO MATCH EXISTING.
3 DISCONNECT AND REMOVE 1-1/2" LAB WASTE AND TRAP BACK TO EXISTING RISER
IN WALL. PREPARE FOR CONNECTION OF ADA SINK IN LAB B40. CUT AND PATCH
WALL AS REQUIRED TO ACCESS PIPING. PATCH WALL TO MATCH EXISTING.
P-101 KEYED RENOVATION NOTES
1 CONNECT TO EXISTING COMPRESSED AIR SUPPLY ABOVE CEILING AS REQUIRED
TO PROVIDE COMPRESSED AIR CONNECTIONS AT LAB TABLES.
2 PROVIDE COMPRESSED AIR DROP TO BELOW CEILING. MOUNT PIPING TO UTILITY
RACK/PLATFORM AND TERMINATE WITH PRESSURE REGULATOR ASSEMBLY AND
ONE (1) 1/4" SWAGELOK CONNECTION. AIR SUPPLY TO SERVE OPTICS TABLE
PNEUMATIC ISOLATORS. REFER TO 5/P-101.
3 REMOVE EXISITNG FLOOR DRAIN GRATE AND REPLACE WITH GASKETED CLEANOUT
TOP. COORDINATE WITH FLOOR FINISH.
4 OWNER PROVIDED POINT OF USE OIL-LESS AIR COMPRESSOR TO SERVE
RHEOMETER. NOTED AND SHOWN FOR REFERENCE ONLY.
5 CUT AND PATCH WALL AS REQUIRED TO CONNECT TO EXISTING LAB WASTE, LAB
VENT, DOMESTIC COLD, AND DOMESTIC HOT WATER SERVICES WITHIN WALL FOR
LAB SINK IN B40. ROUTE PIPING WITHIN BASE CABINET CHASEWAY.
6 INSTALL MIXING VALVE WITHIN SINK BASE CABINET. PROVIDE 1/2" COLD AND 1/2"
HOT WATER SUPPLY TO MIXING VALVE. PROVIDE 1/2" TEMPERED WATER SUPPLY
FROM MIXING VALVE TO EYEWASH.
7 PROVIDE COMPRESSED AIR DROP TO BELOW CEILING. MOUNT PIPING TO UTILITY
RACK/PLATFORM AND TERMINATE WITH PRESSURE REGULATOR ASSEMBLY AND
TWO (2) 1/4" SWAGELOK CONNECTIONS. AIR SUPPLY TO SERVE OPTICS TABLE
PNEUMATIC ISOLATORS. REFER TO 5/P-101.
8 PROVIDE COMPRESSED AIR DROP TO BELOW CEILING. MOUNT PIPING TO EXISTING
WALL AND TERMINATE 6" ABOVE SINK BACKSPLASH WITH PRESSURE REGULATOR
ASSEMBLY AND ONE (1) 1/4" SWAGELOK CONNECTION. AIR SUPPLY TO SERVE
GENERAL LAB USE/TOOL CONNECTIONS.
9 CUT AND CAP EXISTING 1-1/2" PIPE STUB AT FINISH FLOOR LEVEL AS REQUIRED TO
ACCOMODATE FLOOR FINISH. COORDINATE WITH FLOOR FINISH.
SCALE:1/2" = 1'-0"4 ADA LAB SINK CALLOUT DETAIL
#
#
SCALE:1/4" = 1'-0"3 PARTIAL FIRST FLOOR CONSTRUCTION PLAN
SCALE:1/2" = 1'-0"5 LAB SERVICE CONNECTION ELEVATION
1 08/04/20 ISSUE FOR DD REVIEW
2 09/01/20 ISSUE FOR 90% CD REVIEW
3 09/29/20 ISSUE FOR COORDINATED REVIEW
4 10/12/20 ISSUE FOR CONSTRUCTION
0' 4' 8' 16'
SCALE: 1/8"=1'-0"
0' 2' 4' 8'
SCALE: 1/4"=1'-0"
0' 1' 2' 4'
SCALE: 1/2"=1'-0"