HomeMy WebLinkAboutBartels Hall FA Replacement_Signed Dwgs INDEXEDTEAGLE HALL SCHOELLKOPF MEMORIAL HALL 2602B CAMPUS ROAD LYNAH RINK 2613 CAMPUS ROAD BARTELS HALL2631 FRIEDMAN WRESTLINGCENTER 2638 Friedman Strength & Conditioning2631A 6 7 8 CB122A 122A 102 10065 10045 10021 10011 103B 103A 103 10060 10061 108 10022 10066 11010047 112D 112C 112B 10067 112A 101 10043 10044 10003 1000410050 10012 10042 10041 10001 10002 112 10052 10040 1000810007 1000610005 10053 10051 10046 10062 DISPLAY CASECONCESSION STAND122 104 106 10064 10048 SEE BASEMENTPLAN 10014 112E 112F 112G UP UPDN UP UP DN DN DN DN UP DNUP UP UP UP DN UP UP UP UPUPUP10068 115A 115B 115 10054 10015 10014 UP UP BARTELS HALL 2631 CAMPUS ROAD FRIEDMAN STRENGTH AND CONDITIONING 2631A CORNE LL U N I V E R SI TYFOUN D E D 5681AD CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 Cornell University 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT T-001 12675138 TITLE SHEET FE DESIGN JD 2631, 2631A SEPTEMBER 18, 2020 BARTELS HALL FIRE ALARM REPLACEMENT T-001 TITLE SHEET ELECTRICAL E-001 GENERAL NOTES AND SYMBOL LEGENDS E-100 BUILDING 2631 EXISTING AND PHASE 2 BASEMENT FIRE ALARM PLAN E-101 BUILDING 2631 AND 2631A EXISTING AND PHASE 2 FIRST FLOOR FIRE ALARM PLAN E-102 BUILDING 2631 AND 2631A EXISTING AND PHASE 2 SECOND FLOOR FIRE ALARM PLAN E-103 BUILDING 2631 EXISTING AND PHASE 2 THIRD FLOOR FIRE ALARM PLAN E-200 BUILDING 2631 NEW FA SYSTEM BASEMENT PLAN AREA 1 E-201 BUILDING 2631 AND 2631A NEW FIRE ALARM SYSTEM FIRST FLOOR PLAN AREAS 2 & 3 E-202 BUILDING 2631 AND 2631A NEW FIRE ALARM SYSTEM SECOND FLOOR PLANS AREAS 3, 4 & 5 E-203 BUILDING 2631 NEW FIRE ALARM SYSTEM THIRD FLOOR PLAN AREAS 4, 5, & 6 E-301 DETAILS E-401 RISER DIAGRAM SITE LOCATION -BARTELS HALL & FRIEDMAN STRENGTH AND CONDITIONING KEY PLAN -ALL FLOOR LEVELS IN 2631 & 2631A AREA OF WORK BUILDING CODE SUMMARY APPLICABLE CODES 2020 (EXISTING) IBC (ADOPTED BY NEW YORK STATE) PROJECT SUMMARY THIS PROJECT IS TO REPLACE THE EXISTING FIRE ALARM SYSTEM. THE WORK IS ALTERATION LEVEL 2. BUILDING LIMITATIONS CONSTRUCTION CLASSIFICATION:1B CLASSIFICATION OF HAZARDS:NONE HIGH-RISE BUILDING:NO EXTINGUISHING REQUIREMENT:THE EXISTING BUILDING IS SPRINKLERED OCCUPANCY OCCUPANCY CLASSIFICATION:MIXED USE B/A-4 FIRST FLOOR 2631 AREA OF WORK DRAWING INDEX PROJECT SCOPE PROVIDE NEW ADDRESSABLE VOICE FIRE ALARM SYSTEM AND ASSOCIATED RACEWAYS IN BARTELS HALL AND FRIEDMAN STRENGTH AND CONDITIONING. REMOVE ALL OF THE EXISTING FIRE ALARM SYSTEM UPON ACCEPTANCE OF NEW FIRE ALARM SYSTEM. GENERAL SYMBOLS LEGEND EXTERIOR ELEVATION 1 1 1 1X-100 X-100 1 1 1 1 INTERIOR ELEVATION 1 X-100 SECTION MARKER 1 X-100 ENLARGED DETAIL #CONSTRUCTION KEYED NOTE DEMOLITION KEYED NOTE# DRAWING REVISION NOTE# LINETYPE: TO BE PROVIDED / NEW LINETYPE: DEMOLITION / TO BE RELOCATED LINETYPE: EXISTING TO REMAIN FIRST FLOOR 2631A BARTELS HALL & FRIEDMAN STRENGTH AND CONDITIONING 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-001 12675138 GENERAL NOTES AND SYMBOL LEGENDS H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 ELECTRICAL SUBMITTAL SCHEDULE MATERIAL SCHEDULE/ SHOP DWGS. PRODUCT DATA SAMPLES INSPECTIONS & TESTS O&M DATA WARRANTIES FIRE ALARM CONTROL PANEL X X MUX PAD X X TRANSPONDER PANEL X X LOCAL OPERATORS CENTER X X GYM PAGING PANEL X X BATTERY CABINET X X POWER BOOSTER PANEL X X TERMINAL CABINET X X FIRE ALARM DEVICES (SEE E-401)X X ELECTRICAL LEGEND MOTOR HARDWIRED EQUIPMENT CONNECTION P-1A 12 HOMERUN TO PANEL P-1A, CIRCUIT #12. FED FROM 20A -1P BREAKER IS INTENDED UNLESS NOTED OTHERWISE. RUN GREEN WIRE GROUND FOR ALL CIRCUITS. PROVIDE ONE GROUND PER CIRCUIT. EMERGENCY POWER OFF (EPO) GROUND ROD ELECTRODE DUPLEX RECEPTACLE WITH GFCI PROTECTION DUPLEX RECEPTACLE WITH AFCI PROTECTION QUAD RECEPTACLE LINETYPES LEGEND SPECIAL RECEPTACLE5-30R PANELBOARD JUNCTION BOX B = INSTALLED IN BASEBOARD TR = INSTALLED IN WOOD TRIM/CASEWORK/WAINSCOTT SR = SURFACE RACEWAY WP = WEATHERPROOF AC = AIR CONDITIONER X DUPLEX RECEPTACLE: DOUBLE DUPLEX RECEPTACLE MOTOR STARTER J SAFETY SWITCH (NON-FUSED) SAFETY SWITCH (FUSED) FIRE ALARM LEGEND FIRE ALARM CONTROL PANEL BATTERY CABINET WATER FLOW SWITCH MUXPAD REMOTE ANNUNCIATOR D = DUCT SMOKE DETECTOR R = RELAY BASE BR = BEAM RECEIVER BT = BEAM TRANSMITTER SB = SOUNDER BASE W = WALL MOUNTED WP = WEATHER PROOF SMOKE DETECTOR: TAMPER SWITCH AUDIBLE NOTIFICATION APPLIANCE/VOICE/SPEAKER FACP BATT MUX FAA NAC PANELNAC MANUAL PULL STATIONF S X F = FIXED TEMPERATURE R = RATE OF RISE R/F = COMBINATION RISE/FIXED TEMPERATURE HEAT DETECTOR: H X CARBON MONOXIDE DETECTORCO F XXcd C FS S XXcd C TS ADDRESSABLE MONITOR MODULE XXcd = CANDELA C = CEILING CLG = CEILING WG = WIREGUARD COMBO A/V NOTIFICATION APPLIANCE: SPEAKER/ STROBE XXcd = CANDELA C = CEILING VISUAL NOTIFICATION APPLIANCE: SUPPRESSION SYSTEM UNDERGROUND ELECTRICUE UNDERGROUND LIGHTINGUL OVERHEAD ELECTRICOE TO BE PROVIDED DEMOLITION / TO BE RELOCATED EXISTING TO REMAIN UNDERGROUND TELCOUC GENERAL ELECTRICAL DEMOLITION NOTES 1.0 ELECTRICAL EQUIPMENT SHOWN DASHED ON DEMOLITION DRAWINGS, INCLUDING ASSOCIATED ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS, AND OTHER APPURTENANCES NOT SHOWN, SHALL BE DISCONNECTED AND REMOVED. REMOVE ASSOCIATED BRANCH CIRCUITRY TO SOURCE, UNLESS NOTED OTHERWISE. 2.0 EXISTING RACEWAYS AND DEVICE BACKBOXES NOT INTERFERRING WITH NEW WORK SHALL BE REUSED WHERE POSSIBLE. 3.0 PROVIDE JUNCTION BOXES, RACEWAYS, AND WIRING TO MODIFY/EXTEND EXISTING SYSTEMS AND CIRCUITS FED DOWNSTREAM OF ELECTRICAL EQUIPMENT SHOWN TO BE DEMOLISHED. 4.0 CUT DEMOLISHED CONDUITS INSTALLED THRU WALLS AND FLOORS FLUSH WITH THE SURFACE AND PATCH PENETRATIONS (FIRESTOP IF LOCATED ON A FIRE RATED SURFACE). PATCH AND PAINT SURFACES IN EXPOSED AREAS TO MATCH SURROUNDING MATERIALS, FINISHES, AND COLORS. 5.0 PROVIDE BLANK COVERPLATES ON UNUSED BACKBOXES REMAINING FROM DEMOLITION NOT SPECIFIED TO BE INFILLED. 6.0 EXISTING EQUIPMENT SHOWN TO REMAIN SHALL BE PROTECTED DURING CONSTRUCTION. 1.0 PROVIDE NEW ADDRESSABLE FIRE ALARM CONTROL PANEL (FACP). 2.0 PROVIDE CLASS B FOR THE INITIATION CIRCUITS. CLASS A FOR THE NOTIFICATION CIRCUITS. 3.0 PROVIDE NEW ADDRESSABLE INITIATING DEVICE IN ALL COMMON AREAS OF BUILDING. 4.0 PROVIDE NEW NOTIFICATION APPLIANCES AS INDICATED. 5.0 PROVIDE MUXPAD INTERFACE WITH CORNELL UNIVERSITY CENTRAL STATION. 6.0 REMOVE ALL OF THE EXISTING FIRE ALARM SYSTEM UPON ACCEPTANCE OF NEW FIRE ALARM SYSTEM. 7.0 CHECK ALL SMOKE DETECTORS FOR LISTED SENSITIVITY AND TO CLEAN/REPLACE THOSE DEVICES THAT DO NOT MEET THE LISTED SENSITIVITY AT NO ADDITIONAL COST. ELECTRICAL SCOPE OF WORK 1.0 THESE DRAWINGS ARE FOR CORNELL UNIVERSITY USE ONLY. CONTACT THE CORNELL PROJECT MANAGER WITH ELECTRICAL QUESTIONS. 2.0 ELECTRICAL SCHEMATICS INDICATED ON CONTRACT DOCUMENTS ARE DIAGRAMMATIC. IT IS NOT THE INTENT TO SHOW EXACT OR MOST EFFICIENT ROUTING. VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ON SITE. ANY CONFLICTS BETWEEN CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALL BE BROUGHT TO CORNELL'S PROJECT MANAGER FOR RESOLUTION BEFORE WORK PROCEEDS. 3.0 ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOINING AREAS FROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE AND DISPOSE OF WASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISES FREE OF DEBRIS FROM THE EXECUTION OF WORK. DELIVER A FINAL PRODUCT THAT IS CLEAN AND OPERABLE. 4.0 FIRE STOP ELECTRICAL PENETRATIONS THROUGH FIRE RATED WALLS AND/OR FLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTION OF THE MATERIAL PENETRATED. 5.0 PERFORM WORK IN ACCORDANCE WITH THE REQUIREMENT OF THE LATEST PUBLICATIONS OF THE NEC, NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING CODE, NEW YORK STATE ENERGY CODE, AND LOCAL CODES APPLICABLE TO THE PARTICULAR WORK. 6.0 WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACT DOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHOD OF INSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FOR APPROVAL PRIOR TO ORDERING ANY MATERIALS OR COMMENCING EXECUTION OF THE WORK. 7.0 GROUNDING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 250. PROVIDE EQUIPMENT GROUND CONDUCTOR WITH EACH BRANCH CIRCUIT INDICATED ON CONTRACT DOCUMENTS. EQUIPMENT GROUND CONDUCTOR SHALL BE ROUTED WITH ASSOCIATED PHASE CONDUCTORS. 8.0 PROVIDE A NEW TYPE WRITTEN DIRECTORY FOR EACH PANELBOARD. LABEL ALL NEW DEVICE FACEPLATES WITH SOURCE AND CIRCUIT NUMBER. PROVIDE PERMANENT LABEL ON SWITCHING DEVICES INDICATING EQUIPMENT SERVICE AND INVENTORY NUMBER. COORDINATE EQUIPMENT INVENTORY NUMBERS WITH CORNELL UNIVERSITY'S MECHANICAL SHOP, 255-S667. 9.0 CIRCUITS RATED 20-AMP, 120 VOLT SHALL CONTAIN SEPARATE NEUTRAL CONDUCTORS. 10.0 CONDUCTORS SHALL BE A MINIMUM 12AWG, STRANDED COPPER, 600VAC, 90 DEGREE C, TYPE THHN/THWN FOR DRY AREAS AND XHHW/THWN FOR WET AREAS. 11.0 CONDUIT EXPANSION JOINTS SHALL BE INSTALLED AS PER NEC AND WHERE BUILDING VIBRATION JOINTS EXIST. 12.0 CONDUITS SHALL BE A MINIMUM OF 3/4 INCHES DIAMETER. CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT) FOR THIS INSTALLATION, SURFACE MOUNTED UNLESS NOTED OTHERWISE. 13.0 WIREMOLD RACEWAY SHALL BE A MINIMUM OF 700 WIREMOLD FOR INDIVIDUAL DEVICES AND 2400 WIREMOLD OR LARGER FOR MULTIPLE CIRCUITS. WIREMOLD SHALL BE COLOR "IVORY" . 14.0 AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OF RESPECTIVE PANELBOARD. SIZE AS INDICATED. 15.0 PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDE SUPPORT HANGERS FOR CONDUIT AS NEEDED. 16.0 INSTALL RACEWAY SYSTEMS ENSURING PROPER ACCESS TO EQUIPMENT AND DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. RACEWAYS THAT ARE NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. 17.0 DISCREPANCIES BETWEEN THESE DRAWINGS AND ASSOCIATED SPECIFICATIONS ARE TO BE BROUGHT TO THE ATTENTION OF FACILITIES ENGINEERING FOR RESOLUTION. GENERAL NOTES 3.0 SUBMITTALS: A. GENERAL SUBMITTAL REQUIREMENTS: 1. SUBMITTALS SHALL BE APPROVED BY CORNELL UNIVERSITY'S FACILITIES ENGINEERING AND ENVIRONMENTAL HEALTH AND SAFETY. 2. SHOP DRAWINGS SHALL BE PREPARED BY PERSONS WITH THE FOLLOWING QUALIFICATIONS: a. TRAINED AND CERTIFIED BY MANUFACTURER IN FIRE-ALARM SYSTEM DESIGN. b. NICET-CERTIFIED FIRE-ALARM TECHNICIAN, LEVEL Ill MINIMUM OR LICENSED PROFESSIONAL B. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. C. SHOP DRAWINGS: FOR FIRE-ALARM SYSTEM. INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS, AND ATTACHMENTS TO OTHER WORK. 1. SYSTEM RISER DIAGRAM WITH TYPICAL EQUIPMENT AND DEVICE CONNECTION. 2. INCLUDE VOLTAGE DROP CALCULATIONS FOR NOTIFICATION APPLIANCE CIRCUITS. 3. INCLUDE BATTERY-SIZE CALCULATIONS. 4. INCLUDE FLOOR PLANS TO INDICATE FINAL OUTLET LOCATIONS SHOWING ADDRESS OF EACH ADDRESSABLE DEVICE. SHOW SIZE AND ROUTE OF CABLE AND CONDUITS. 5. INCLUDE WIRE COLOR-CODING SCHEDULE. 4.0 SOFTWARE SERVICE AGREEMENT A. COMPLY WITH UL 864. B. TECHNICAL SUPPORT: BEGINNING WITH SUBSTANTIAL COMPLETION, PROVIDE SOFTWARE SUPPORT FOR TWO YEARS. FREE RE-PROGRAMMINGS (2) OF SYSTEM TO ENSURE ALL POINTS ARE ADDRESSED AS NEEDED PER CORNELL ENVIRONMENTAL HEALTH & SAFETY (EH&S). C. UPGRADE SERVICE: UPDATE SOFTWARE TO LATEST VERSION AT PROJECT COMPLETION. INSTALL AND PROGRAM SOFTWARE UPGRADES THAT BECOME AVAILABLE WITHIN TWO YEARS FROM DATE OF SUBSTANTIAL COMPLETION. UPGRADING SOFTWARE SHALL INCLUDE OPERATING SYSTEM. UPGRADE SHALL INCLUDE NEW OR REVISED LICENSES FOR USE OF SOFTWARE. 5.0 MANUFACTURERS A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1.GAMEWELL FIRE CONTROL INSTRUMENTS, INC.; A HONEYWELL COMPANY. 2. HONEYWELL/NOTIFIER 3.EDWARD SYSTEM TECHNOLOGIES (EST). 6.0 FIRE-ALARM CONTROL PANEL A. GENERAL REQUIREMENTS FOR FIRE-ALARM CONTROL UNIT: 1. FIELD-PROGRAMMABLE, MICROPROCESSOR-BASED, MODULAR, POWER-LIMITED DESIGN WITH ELECTRONIC MODULES, COMPLYING WITH UL 864 AND LISTED AND LABELED BY AN NRTL. 2. ADDRESSABLE CONTROL CIRCUITS FOR OPERATION OF MECHANICAL EQUIPMENT. B. ALPHANUMERIC DISPLAY AND SYSTEM CONTROLS: ARRANGED FOR INTERFACE BETWEEN HUMAN OPERATOR AT FIRE ALARM CONTROL UNIT AND ADDRESSABLE SYSTEM COMPONENTS INCLUDING ANNUNCIATION AND SUPERVISION. DISPLAY ALARM, SUPERVISORY, AND COMPONENT STATUS MESSAGES AND THE PROGRAMMING AND CONTROL MENU. 1. ANNUNCIATOR AND DISPLAY: LIQUID CRYSTAL TYPE (1), (2), (3) LINE(S} OF (40) (80) CHARACTERS TRUMMUM. 2. KEYPAD: ARRANGED TO PERMIT ENTRY AND EXECUTION OF PROGRAMMING, DISPLAY, AND CONTROL COMMANDS AND TO INDICATE CONTROL COMMANDS TO BE ENTERED INTO THE SYSTEM FOR CONTROL OF SMOKE DETECTOR SENSITIVITY AND OTHER PARAMETERS. a. DESIGNATE KEY/ BUTTON FOR MONTHLY ALARM TESTING (ONLY SENDS ALARM CONDITION TO CENTRAL CONSOLE). 3. INMATING DEVICE, NOTIFICATION APPLIANCE, AND SIGNALING LINE CIRCUITS: NFPA 72. a. INITIATING DEVICE CIRCUITS: STYLE D (CLASS A). b. NOTIFICATION APPLIANCE CIRCUITS: STYLE Z (CLASS A). ALTERNATING NOTIFICATION CIRCUITS ON SLEEPING LEVELS. c. SIGNALING LINE CIRCUITS: STYLE D. d. INSTALL NO MORE THAN 50 ADDRESSABLE DEVICES ON EACH SIGNALING LINE CIRCUIT. C. NOTIFICATION APPLIANCE CIRCUIT: OPERATION SHALL SOUND IN A TEMPORAL 3 PATTERN (FIRE) AND TEMPORAL 4 PATTERN FOR CO DETECTION. D. TRANSMISSION TO REMOTE ALARM RECEIVING STATION: AUTOMATICALLY TRANSMIT ALARM, SUPERVISORY, AND TROUBLE SIGNALS TO A REMOTE ALARM STATION. E. PRIMARY POWER: 24--VDC OBTAINED FROM 120-VAC SERVICE AND A POWER- SUPPLY MODULE. INITIATING DEVICES, NOTIFICATION APPLIANCES, SIGNALING LINES, TROUBLE SIGNALS, SHALL BE POWERED BY 24-VDC SOURCE. 1. ALARM CURRENT DRAW OF ENTIRE FIRE-ALARM SYSTEM SHALL NOT EXCEED 80 PERCENT OF THE POWER SUPPLY MODULE RATING. F. SECONDARY POWER: 24-VDC SUPPLY SYSTEM WITH BATTERIES, AUTOMATIC BATTERY CHARGER, AND AUTOMATIC TRANSFER SWITCH. 1. BATTERIES: SEALED LEAD ACID. G. INSTRUCTIONS: COMPUTER PRINTOUT OR TYPEWRITTEN INSTRUCTION CARD MOUNTED BEHIND A PLASTIC OR GLASS OVER IN A STAINLESS-STEEL OR ALUMINUM FRAME. INCLUDE INTERPRETATION AND DESCRIBE APPROPRIATE RESPONSE FOR DISPLAYS AND SIGNALS. BRIEFLY DESCRIBE THE FUNCTIONAL OPERATION OF THE SYSTEM UNDER NORMAL, ALARM, AND TROUBLE CONDITIONS. 7.0 MANUAL FIRE-ALARM BOXES A. GENERAL REQUIREMENTS FOR MANUAL FIRE-ALARM BOXES: COMPLY WITH UL 38. BOXES SHALL BE FINISHED IN RED WITH MOLDED, RAISED-LETTER OPERATING INSTRUCTIONS IN CONTRASTING COLOR; SHOW VISIBLE INDICATION OF OPERATION; AND SHALL BE MOUNTED ON RECESSED OUTLET BOX. IF INDICATED AS SURFACE MOUNTED, PROVIDE MANUFACTURER'S SURFACE BACK BOX. 1. DOUBLE-ACTION MECHANISM REQUIRING TWO ACTIONS TO INITIATE AN ALARM, PULL-LEVER TYPE WITH INTEGRAL ADDRESSABLE MODULE ARRANGED TO COMMUNICATE MANUAL-STATION STATUS (NORMAL, ALARM, OR TROUBLE) TO FIRE-ALARM CONTROL UNIT. 2. STATION RESET: KEY OPERATED SWITCH. 8.0 SYSTEM SMOKE DETECTORS A. GENERAL REQUIREMENTS FOR SYSTEM SMOKE DETECTORS: 1. COMPLY WITH UL 268; OPERATING AT 24--VDC, NOMINAL. 2. DETECTORS SHALL BE TWO-WIRE TYPE. 3. INTEGRAL ADDRESSABLE MODULE: ARRANGED TO COMMUNICATE DETECTOR STATUS (NORMAL, ALARM, OR TROUBLE) TO FIRE-ALARM CONTROL UNIT. 4. BASE MOUNTING: DETECTOR AND ASSOCIATED ELECTRONIC COMPONENTS SHALL BE MOUNTED IN A TWIST-LOCK MODULE THAT CONNECTS TO A FIXED BASE. PROVIDE TERMINALS IN THE FIXED BASE FOR CONNECTION TO BUILDING WIRING. 5. DETECTOR SHALL NOT BE MOUNTED WITHIN 3 FEET OF CEILING FAN BLADE TIP, 3' AWAY FROM AIR DIFFUSER OR OUT OF DIRECT LINE OF AIR FLOW. B. PHOTOELECTRIC SMOKE DETECTORS: 1. DETECTOR ADDRESS SHALL BE ACCESSIBLE FROM FIRE-ALARM CONTROL UNIT AND SHALL BE ABLE TO IDENTIFY THE DETECTOR'S LOCATION WITHIN THE SYSTEM AND ITS SENSITIVITY SETTING. 2. AN OPERATOR AT FIRE-ALARM CONTROL UNIT, HAVING THE DESIGNATED ACCESS LEVEL, SHALL BE ABLE TO MANUALLY ACCESS THE FOLLOWING FOR EACH DETECTOR: a. PRIMARY STATUS. b. DEVICE TYPE. c. PRESENT AVERAGE VALUE. d. PRESENT SENSmVITY SELECTED. e. SENSOR RANGE (NORMAL, DIRTY, ETC.). SPECIFICATIONS CONT. FROM LOWER RIGHT C. BEAM DETECTORS: 1. FIRERAY FFE M/N 5000-031 SERIES REFLECTIVE BEAM SMOKE DETECTOR ADD-ON HEAD. 2. FIRERAY FFE M/N 5000-103 SERIES REFLECTIVE BEAM SMOKE DETECTORS WITH GROUND LEVEL TEST STATION. 9.0 HEAT DETECTORS A. GENERAL REQUIREMENTS FOR HEAT DETECTORS: COMPLY WITH UL 521. B. HEAT DETECTOR, COMBINATION TYPE: ACTUATED BY EITHER A FIXED TEMPERATURE OF 135 DEG F (57 DEG C) OR A RATE OF RISE THAT EXCEEDS 15 DEG F (8 DEG C) PER MINUTE UNLESS OTHERWISE INDICATED. 1. MOUNTING: ADAPTER PLATE FOR OUTLET BOX MOUNTING. 2. INTEGRAL ADDRESSABLE MODULE: ARRANGED TO COMMUNICATE DETECTOR STATUS (NORMAL, ALARM, OR TROUBLE) TO FIRE-ALARM CONTROL UNIT. C. HEAT DETECTOR, FIXED-TEMPERATURE TYPE: ACTUATED BY TEMPERATURE THAT EXCEEDS A FIXED TEMPERATURE OF 190 DEG F (88 DEG C). 1. MOUNTING: ADAPTER PLATE FOR OUTLET BOX MOUNTING. 2. INTEGRAL ADDRESSABLE MODULE: ARRANGED TO COMMUNICATE DETECTOR STATUS (NORMAL, ALARM, OR TROUBLE) TO FIRE-ALARM CONTROL UNIT. 10.0 NOTIFICATION APPLIANCES A. GENERAL REQUIREMENTS FOR NOTIFICATION APPLIANCES: CONNECTED TO NOTIFICATION APPLIANCE SIGNAL CIRCUITS, ZONED AS INDICATED, EQUIPPED FOR MOUNTING AS INDICATED AND WITH SCREW TERMINALS FOR SYSTEM CONNECTIONS. 1. COMBINATION DEVICES: FACTORY-INTEGRATED AUDIBLE AND VISIBLE DEVICES IN A SINGLE-MOUNTING ASSEMBLY, EQUIPPED FOR MOUNTING AS INDICATED AND WITH SCREW TERMINALS FOR SYSTEM CONNECTIONS. B. SPEAKER: ELECTRIC-VIBRATING-POLARIZED TYPE, 24-VDC; WITH PROVISION FOR HOUSING THE OPERATING MECHANISM BEHIND A GRILLE. COMPLY WITH UL 464. SPEAKER SHALL PRODUCE A SOUND-PRESSURE LEVEL OF 90 OBA, MEASURED 10 FEET (3M) FROM THE SPEAKER, USING THE CODED SIGNAL PRESCRIBED IN UL 464 TEST PROTOCOL. C. VISIBLE NOTIFICATION APPLIANCES: XENON STROBE LIGHTS COMPLY WITH UL 1971, WITH CLEAR OR NOMINAL WHITE POLYCARBONATE LENS MOUNTED ON AN ALUMINUM FACEPLATE. THE WORD "FIRE" IS ENGRAVED IN MINIMUM 1-INCH- (25--MM--) HIGH LETTERS ON THE LENS. 1. RATED LIGHT OUTPUT: a. 15/30/75/110 CD, SELECTABLE IN THE FIELD. 2. MOUNTING: WALL MOUNTED UNLESS OTHERWISE INDICATED. 3. FOR UNITS WITH GUARDS TO PREVENT PHYSICAL DAMAGE, LIGHT OUTPUT RATINGS SHALL BE DETERMINED WITH GUARDS IN PLACE. 4. FLASHING SHALL BE IN A TEMPORAL PATTERN, SYNCHRONIZED WITH OTHER UNITS. 5. STROBE LEADS: FACTORY CONNECTED TO SCREW TERMINALS. 6. MOUNTING FACEPLATE: FACTORY FINISHED RED. 7. STROBES SHOULD BE SYNCHRONIZED. 11.0 ADDRESSABLE INTERFACE DEVICE A. DESCRIPTION: MICROELECTRONIC MONITOR MODULE, NRTL LISTED FOR USE IN PROVIDING A SYSTEM ADDRESS FOR ALARM-INITIATING DEVICES FOR WIRED APPLICATIONS WITH NORMALLY OPEN CONTACTS. 12.0 COMMUNICATION A. TRANSMISSION OF ALARM, SUPERVISORY AND TROUBLE SIGNAL BY MUXPAD. 13.0 EQUIPMENT INSTALLATION A. COMPLY WITH NFPA 72 AND CUDCS 283100 FOR INSTALLATION OF FIRE-ALARM EQUIPMENT. B. EQUIPMENT MOUNTING: INSTALL FIRE-ALARM CONTROL UNIT ON FINISHED FLOOR WITH TOPS OF CABINETS NOT MORE THAN 72 INCHES (1830 MM) ABOVE THE FINISHED FLOOR. C. SMOKE-OR HEAT-DETECTOR SPACING: 1. COMPLY WITH NFPA 72, "SMOKE-SENSING FIRE DETECTORS" SECTION IN THE "INITIATING DEVICES" CHAPTER, FOR SMOKE-DETECTOR SPACING. 2. COMPLY WITH NFPA 72, "HEAT-SENSING FIRE DETECTORS" SECTION IN THE "INITIATING DEVICES" CHAPTER, FOR HEAT-DETECTOR SPACING. 3. SMOOTH CEILING SPACING SHALL NOT EXCEED 30 FEET (9 M). 4. SPACING OF DETECTORS FOR IRREGULAR AREAS, FOR IRREGULAR CEILING CONSTRUCTION, AND FOR HIGH CEILING AREAS SHALL BE DETERMINED ACCORDING TO APPENDIX A IN NFPA 72. D. COMBINATION NOTIFICATION DEVICES: FACTORY-INTEGRATED AUDIBLE AND VISIBLE DEVICE: INSTALL NOT LESS THAN 6 INCHES (150 MM) BELOW THE CEILING, AS REQUIRED PER NFPA 72, AND AS SPECIFIED ON THE DRAWINGS. F. COMBINATION NOTIFICATION DEVICES NEED TO FOLLOW MOUNTING REQUIREMENTS FOR VISUAL PORTION OF THE DEVICE. 14.0 IDENTIFICATION A. PROVIDE LETTERED PLATES FOR THE FOLLOWING EQUIPMENT, COMPONENTS, AND ACCESSORIES. THE PLATE SHALL CONTAIN THE EQUIPMENT IDENTIFICATION (CUSTOM PANEL NUMBER, AREA SERVED) AS WELL AS POWER CIRCUIT SOURCE AND BREAKER NUMBER. LABEL SHALL BE PLASTIC LAMICOID ENGRAVED PLATED OR APPROVED EQUAL. (NOTE: ALL LETTERED PLATES SHALL BE REVIEWED AND APPROVED BY CORNELL UNIVERSITY'S ENVIRONMENTAL HEALTH AND SAFETY PRIOR TO INSTALLATION.) 1. FIRE ALARM CONTROL PANELS, REMOTE POWER SUPPLIES. 2. JUNCTION BOX COVER SHALL BE IN RED COLOR. B. PROVIDE COMPUTER-GENERATED ADHESIVE LABELS AND INSTALL ON THE BASES OF ALL INITIATING DEVICE AND NOTIFICATION APPLIANCES, AS WELL AS ANY REMOTE TEST AND MONITORING STATIONS. THE LABEL SHALL INDICATE THE ADDRESS AND MUST BE LEGIBLE FROM A STANDING POSITION BELOW. 1. LABELING GUIDELINE FOR SIGNALING LINE CIRCUIT (SLC): FACPIBOARD -LOOPICCT # -DEVICE #. 2. LABELING GUIDELINE FOR NOTIFICATION APPLIANCE CIRCUIT (NAC): FACPIBOARD -LOOP/CCR# -DEVICE# (WHERE ADDRESSABLE). 15.0 FIELD QUALITY CONTROL A. A FIRE ALARM PROGRAM LIST TO BE PROVIDED TO EH&S FOR REVIEW AND APPROVAL PRIOR TO RELEASE TO THE FIRE ALARM VENDOR. THIS EFFORT IS TO ALLOW FOR THE FIRE ALARM DEVICE DESCRIPTORS AND ROOM NUMBERS TO BE COORDINATED PRIOR TO ENTERING INTO THE FIRE ALARM PANEL, AS WELL AS TO VERIFY THE PROGRAMMING AND OPERATIONAL SEQUENCE. B. ACCEPTANCE TESTING: 1. PROVIDE MINIMUM (72) HOURS PRIOR NOTICE TO EH&S AND AHJ. 2. COMPLETE AND SUBMIT PROGRAM SHEETS TO EH&S. 3. ENSURE THAT THE SYSTEM IS PRE-TESTED. 4. CONTRACTOR TO PROVIDE ALL TESTING EQUIPMENT. 5. SMOKE DETECTORS SHALL BE TESTED BY SMOKE. 6. HEAT DETECTORS SHALL BE TESTED BY HEAT. 7. CO DETECTORS SHALL BE TESTED PER MANUFACTURES RECOMMENDATIONS. C. AS-BUILT DOCUMENTATION: REVISE RISER DIAGRAM, BASED ON ACTUAL CONDITIONS, TO INDICATE ALL DEVICE CONNECTIONS AND LABELING AND SETTINGS, EQUIPMENT LOCATIONS, COMMUNICATION CONNECTION, AND POWER SOURCES. 1. COPIES OF AS BUILT DOCUMENTATION SHALL BE PROVIDED TO PROJECT MANAGER, EH&S AND CORNELL UNIVERSITY FACILITIES ENGINEERING. SPECIFICATIONS CONT. FROM LOWER RIGHT 1.0 FIRE ALARM SYSTEM SHALL BE INSTALLED PER ALL APPLICABLE CODES (NYSBC, FIRE CODE, NFPA 72 AND NEC) AND STANDARDS (CUDCS). 2.0 SYSTEM DESCRIPTION: A. NON-CODED, ADDRESSABLE SYSTEM, WITH MULTIPLEXED SIGNAL TRANSMISSION, DEDICATED TO FIRE-ALARM SERVICE ONLY. SPECIFICATIONS V J XX SC = DOOR SELF-CLOSER/HOLDER FS = FIRE SHUTTER WG WG = WIREGUARD BEAM DETECTORBD MOUNTING HEIGHTS CARD READER 48" TOP OF BOX LIGHT SWITCH 48" TOP OF BOX RECEPTACLE 18" TOP OF BOX DATA OUTLET 18" TOP OF BOX TV OUTLET 84" TOP OF BOX PHONE OUTLET 48" TOP OF BOX SAFETY SWITCH 60" CENTERLINE OF HANDLE MOTOR STARTER 60" CENTERLINE OF HANDLE PANELBOARD 72" TOP OF PANELBOARD MANUAL PULL STATION 48" OPERABLE HANDLE NOTIFICATION APPLIANCE 80" BOTTOM OF LENS DOOR HOLD OPEN COORDINATE IN FIELD EM BATTERY UNIT 96" BOTTOM OF UNIT EM REMOTE UNIT 102" BOTTOM OF UNIT EXIT SIGN 96" BOTTOM OF UNIT 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION AMM ADDRESSABLE OUTPUT MONITORAOM TANDEM RELAY MODULEMR UP UPUP UPUP B16 B18 B20 B22 B24 B26 B28 B30 B32 B34 B36 B38 B0027 B0026 B0042 B17 B21 B23 B0028 B31 B33 B39 B0046 B0001B0066 B0063 B0053 B0065 B0040 B07 B07A B0068 B0069 B0062 B0061 B06 B06A B0052 B01 B01A B0003 B0004 B0002 B0060 B46A B46 B46C B46D B51 B42 B47B B47A B49 B44 B40 B0055 B40A B0056 B45 B41 B43 B46B B47C B47 B0064 B0054 B0031 B0030 B0051 B07B B07C B0021 B0022 B0023 B0025 B0024 B0020 B0067 B0029 B0020A B0024A B0063 B0053 B0065 B0062 B0061 B0052 B0002 B0060 B0064 B0054 B0051FS S S S S S S S S S S S S S S S S S S S S SS S S S S FFFFFFS FF F FFROLLING DOOR S S S H H ELEV.FF E-100 1 F WP S ELEV. MECH. F S S S S S FF F F F S MAIN ELECTRIC ROOM INDICATES EXISTING SPRINKLER HEAD (TYPICAL ON DRAWING) INDICATES EXISTING FIRE ALARM DEVICE (TYPICAL ON DRAWING) ALL COMBO NOTIFICATION APPLIANCES ARE SPEAKER/STROBE DEVICES TS TS TS TS FS FS FS FS TS EXISTING FIRE ALARM CONTROL PANEL. SEE PHOTO. EXISTING VOICE EVACUATION ALARM BOX. SEE PHOTO CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-100 12675138 BUILDING 2631 EXISTING AND PHASE 2 BASEMENT FIRE ALARM PLAN H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 0' 4' 8'16' SCALE: 1/8"=1'-0" SCALE:1/16" = 1'-0"2 FULL BASEMENT PLAN 0' 8' 16' 32' SCALE: 1/16"=1'-0" GENERAL NOTES 1. PHASE 1, PROVIDE NEW FIRE ALARM SYSTEM. PHASE 2, REMOVE THE EXISTING FIRE ALARM SYSTEM. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL DURING THE INSTALLATION OF THE NEW SYSTEM. 2. PHASE 2, REMOVE EXISTING FIRE ALARM DEVICES AND ASSOCIATED WIRING AND RACEWAYS COMPLETELY BACK TO SOURCE. PROVIDE ELECTRICAL IVORY BLANK PLATES OVER EXISTING BACK BOXES. SCALE:1/8" = 1'-0"1 PARTIAL BASEMENT PLAN ROOM B0064 -FIRE ALARM PANEL & VOICE EVACUATION ALARM BOX 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION 122A 122A 102 10065 10045 10021 10011 103B 103A 103 10060 10061 108 10022 10066 110 10047 112D 112C 112B 10067 112A 101 10043 10044 10003 1000410050 10012 10042 10041 10001 10002 112 10052 10040 1000810007 1000610005 10053 10051 10046 10062 DISPLAY CASECONCESSION STAND122 104 106 10064 10048 SEE BASEMENT PLAN 10014 112E 112F 112G UP UPDN UP UP DN DN DN DN UP DNUP UP UP UP DN UP UP UP UPUPUP10068 115A 115B 115 10054 10015 10014 UP UP 1M12 DN BUILDING 2631A FIRST FLOOR LOCATION OF MEZZANINE FF S S S F FFF S S J FS J FS J FS J FS S FIRE SHUTTER TYPICAL J FIRE SHUTTER S S S S J FIRE SHUTTERFF H S FSTS H FA TERMINAL BOX S S S S ELEV. F F S SFAA EXISTING FA ANNUNCIATION PANEL. SEE PHOTO. S S S S S S S S S S S S S S S S S S F FF F FF F F SSSS D D F F FJ FIRE SHUTTER FF S S S S FF S S F FF F F WG WG F WG S H FS TS H S S EXISTING SPRINKLER HEAD (TYPICAL ON DRAWING) WG INDICATES EXISTING SPRINKLER HEAD (TYPICAL ON DRAWING) INDICATES EXISTING FIRE ALARM DEVICE (TYPICAL ON DRAWING)WG WG ALL COMBO NOTIFICATION APPLIANCES ARE HORNS/STROBES EXISTING VOICE EVACUATION ALARM BOX EXISTING VOICE EVACUATION ALARM BOX EXISTING VOICE EVACUATION ALARM BOX EXISTING FIRE DEPARTMENT VOICE EVACUATION ALARM BOX. TO BE REMOVED (PHASE 2) EXISTING KNOCK BOX LYNAH RINK 1 ALL COMBO NOTIFICATION APPLIANCES IN BARTELS ARE SPEAKER/STROBE DEVICES CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-101 12675138 BUILDING 2631 AND 2631A EXISTING AND PHASE 2 FIRST FLOOR FIRE ALARM PLAN H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 SCALE:1/16" = 1'-0"1 1ST FLOOR GENERAL NOTES 1. PHASE 1, PROVIDE NEW FIRE ALARM SYSTEM. PHASE 2, REMOVE THE EXISTING FIRE ALARM SYSTEM. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL DURING THE INSTALLATION OF THE NEW SYSTEM. 2. PHASE 2, REMOVE EXISTING FIRE ALARM DEVICES AND ASSOCIATED WIRING AND RACEWAYS COMPLETELY BACK TO SOURCE. PROVIDE ELECTRICAL IVORY BLANK PLATES OVER EXISTING BACK BOXES. SCALE:1/8" = 1'-0"2 BUILDING 2631 MEZZANINE 0' 8' 16' 32' SCALE: 1/16"=1'-0" 0' 4' 8' 16' SCALE: 1/8"=1'-0" FA ANNUNCIATION PANEL E-101 KEYED DEMOLITION NOTES 1 REMOVE EXISTING VOICE EVACUATION ALARM BOX AND ASSOCIATED DEVICES AND WIRING COMPLETELY. PROVIDE A WHITE BLANK PLATE OVER EXISTING BACK BOX. # 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION 20011 20012 2001520016 20045 20047 20062 20067 20065 20066 20068 202 204 206 208 210 212 214 215 218 222 224 226 227 228 230 232 240 241 242244 213 217 219 221 223 20040 225 20060 20049 20048 243 2000620005 OPEN TO BELOW OPEN TO BELOW 10013 OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW DN DN DN DN DN DN UPUP DN DN DN DN UP 1M115A 1M115DN DN V V40'40' 40'40' V V 40' 40' 40' BD BD BD40' 40'BD BD BD 40' FF BEAM DETECTOR TYPICAL SSSSS FS FS FSTS TS TS S S S S S S S S S D S D S D S D S D S S S S S S S S D S D S S D S D S H H FFF FFF FS TS FS TSFF FFFF F F S D S SHAFT S ELEV. S F SSS F CLG.F CLG. S EXISTING SPRINKLER HEAD (TYPICAL ON DRAWNG) WALL INDICATES EXISTING FIRE ALARM DEVICE (TYPICAL ON DRAWNG) ALL COMBO NOTIFICATION APPLIANCES ARE HORNS/STROBES SPEAKER (TYPICAL) ALL COMBO NOTIFICATION IN BARTELS APPLIANCES ARE SPEAKER/STROBE DEVICES 0' 8' 16' 32' SCALE: 1/16"=1'-0"CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-102 12675138 BUILDING 2631 AND 2631A EXISTING AND PHASE 2 SECOND FLOOR FIRE ALARM PLAN H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 SCALE:1/16" = 1'-0"1 2ND FLOOR BUILDING 2631A MEZZANINE GENERAL NOTES 1. PHASE 1, PROVIDE NEW FIRE ALARM SYSTEM. PHASE 2, REMOVE THE EXISTING FIRE ALARM SYSTEM. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL DURING THE INSTALLATION OF THE NEW SYSTEM. 2. PHASE 2, REMOVE EXISTING FIRE ALARM DEVICES AND ASSOCIATED WIRING AND RACEWAYS COMPLETELY BACK TO SOURCE. PROVIDE ELECTRICAL IVORY BLANK PLATES OVER EXISTING BACK BOXES. 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION 3P0063 3P0062 3P0017 3P00153P0016 DN DN UP DN ROOFFF BD BD BD BD BD BD BEAM DETECTOR TYPICAL VVVV VVVV S WP S WP STAIR VENT SHAFT VENT SMOKE HATCH TYPICAL S WP S WP STAIR VENT SHAFT VENT S WP S WP HOISTWAY SHAFT VENT S D S D S D S D S D H H FS TSFF S D S D S D S D H H FS TS F FBDBD H H INDICATES EXISTING SPRINKLER HEAD (TYPICAL ON DRAWING) INDICATES EXISTING FIRE ALARM DEVICE (TYPICAL ON DRAWNG) SPEAKER (TYPICAL) 1 1 1 1 1 1 ALL COMBO NOTIFICATION IN BARTELS APPLIANCES ARE SPEAKER/STROBE DEVICES CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-103 12675138 BUILDING 2631 EXISTING AND PHASE 2 THIRD FLOOR FIRE ALARM PLAN H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 SCALE:1/16" = 1'-0"1 3RD FLOOR 0' 8' 16' 32' SCALE: 1/16"=1'-0" GENERAL NOTES 1. PHASE 1, PROVIDE NEW FIRE ALARM SYSTEM. PHASE 2, REMOVE THE EXISTING FIRE ALARM SYSTEM. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL DURING THE INSTALLATION OF THE NEW SYSTEM. 2. PHASE 2, REMOVE EXISTING FIRE ALARM DEVICES AND ASSOCIATED WIRING AND RACEWAYS COMPLETELY BACK TO SOURCE. PROVIDE ELECTRICAL IVORY BLANK PLATES OVER EXISTING BACK BOXES. E-103 KEYED DEMOLITION NOTES 1 REMOVE EXISTING DETECTOR AND ASSOCIATED WIRING COMPLETELY BACK TO SOURCE. MODIFY VENT TO BE OPERATED MANUALLY. # 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION UP UPUP UPUP B16 B18 B20 B22 B24 B26 B28 B30 B32 B34 B36 B38 B0027 B0026 B0042 B17 B21 B23 B0028 B31 B33 B39 B0046 B0001B0066 B0063 B0053 B0065 B0040 B07 B07A B0068 B0069 B0062 B0061 B06 B06A B0052 B01 B01A B0003 B0004 B0002 B0060 B46A B46 B46C B46D B51 B42 B47B B47A B49 B44 B40 B0055 B40A B0056 B45 B41 B43 B46B B47C B47 B0064 B0054 B0031 B0030 B0051 B07B B07C B0021 B0022 B0023 B0025 B0024 B0020 B0067 B0029 B0020A B0024A B0001 B0063 B0053 B0065 B0062 B0061 B0052 B0002 B0060 B0064 B0054 B0051FS S S S S S S S S S S S S S S S S S S S S SS S S S S FFFFFFS FF F FFROLLING DOOR S S S H H ELEV.FF F WP S ELEV. MECH. F S S S S S FF F F F S MAIN ELECTRIC ROOM INDICATES NEW FIRE ALARM DEVICE (TYPICAL ON DRAWING) E-200 1SSSSSSSSSSSSSSSSS S S SS S S SS S SSSSS PROGRAM THE ELEV. SMOKE DETECTOR TO OPERATE THE SMOKE VENT IN THE SHAFT S S HHFF S ELEV. MECH.B0065 -MAIN ELECTRIC ROOM TS TS TS TS FS FS FS FS TS PROPOSED LOCATION OF NEW FA CONTROL PANEL AND ASSOCIATED DEVICES. SEE DRAWING E-301 SEE E-100 FOR EXISTING FA CONTROL PANEL 1 MAIN SPRINKLER ROOM 22 CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-200 12675138 BUILDING 2631 NEW FA SYSTEM BASEMENT PLAN AREA 1 H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 GENERAL NOTES 1. PHASE 1, PROVIDE NEW FIRE ALARM SYSTEM. PHASE 2, REMOVE THE EXISTING FIRE ALARM SYSTEM. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL DURING THE INSTALLATION OF THE NEW SYSTEM. 2. IN UTILITY SPACES, THE USE OF EMT AS SURFACE RACEWAY IS ACCEPTABLE. IN FINISHED SPACES, PROVIDE IVORY WIREMOLD SURFACE RACEWAY. REFER TO KEYED NOTES FOR DETAILS. 3. THIS DRAWING DOES NOT SHOW THE EXISTING SPRINKLER SYSTEM. 4. PROVIDE NEW FIRE ALARM DEVICES AS INDICATED ON DRAWING. NEW DEVICES SHALL BE INSTALLED APPROXIMATELY CLOSE TO THE EXISTING FIRE ALARM DEVICES (SEE EXISTING FA SYSTEM FLOOR PLAN FOR THE EXISTING FA DEVICES LOCATIONS). SCALE:1/16" = 1'-0"2 FULL BASEMENT PLAN NEW WORK AREA 1 SCALE:1/8" = 1'-0"1 PARTIAL BASEMENT PLAN NEW WORK E-200 KEYED CONSTRUCTION NOTES 1 CIRCUIT TEMPER AND FLOW SWITCHES TO THE NEW VELOCITI SERIES MMI-10F PANEL. SEE DRAWING E-301. 2 EXISTING FIRE PUMP SHALL BE MONITORED BY THE NEW FIRE ALARM CONTROL PANEL. SEE E-301 FOR ADDITIONAL INFORMATION. 0' 4' 8' 16' SCALE: 1/8"=1'-0" 0' 8' 16' 32' SCALE: 1/16"=1'-0" # 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION 122A 122A 102 10065 10045 10021 10011 103B 103A 103 10060 10061 108 10022 10066 110 10047 112D 112C 112B 10067 112A 101 10043 10044 10003 1000410050 10012 10042 10041 10001 10002 112 10052 10040 1000810007 1000610005 10053 10051 10046 10062 DISPLAY CASECONCESSION STAND122 104 106 10064 10048 SEE BASEMENT PLAN 10014 112E 112F 112G UP UPDN UP UP DN DN DN DN UP DNUP UP UP UP DN UP UP UP UPUPUP10068 115A 115B 115 10054 10015 10014 UP UP 1M12 DN BUILDING 2631A FIRST FLOOR LOCATION OF MEZZANINE FF S S S F FFF S S J FS J FS J FS J FS S FIRE SHUTTER TYPICAL J FIRE SHUTTER S S S S J FIRE SHUTTERFF S S FSTS S FA TERMINAL BOX S S S S ELEV. F F S SFAA REPLACE FA ANNUNCIATION PANEL S S S S S S S S S S S AC1(R) S S S S S S S F FF F FF F F SSSS D D F F FJ FIRE SHUTTER F S S S S F S S F FF F F WG WG FWG S H FS TS H S AC1(S) S WG INDICATES NEW FIRE ALARM DEVICE (TYPICAL ON DRAWING) WG WG ALL NEW COMBO NOTIFICATION APPLIANCES ARE SPEAKER/STROBES WGWG WG WG ELECTRICAL ROOM ADD NEW FCI M/N HPPFF12 NAC APPLIANCE POWER BOOSTER PANEL & TERMINAL CABINET M/N SSU00645, TC-2, 32 POINT CABINET WG WG SSSS EXISTING FIRE DEPARTMENT VOICE EVACUATION ALARM BOX. TO BE REMOVED (PHASE 2) EXISTING KNOCK BOX ELECTRICAL ROOM ADD NEW FCI M/N HPPFF12 NAC APPLIANCE POWER BOOSTER PANEL & TERMINAL CABINET M/N SSU00645, TC-2, 32 POINT CABINET WG WG AREA 3AREA 2 AREA 3AREA 2 LYNAH RINK 1 1 1 1 CO 7 6 EXISTING VOICE EVACUATION ALARM BOX TO BE REPLACED EXISTING VOICE EVACUATION ALARM BOX TO BE REPLACED 2 2 1 6 3 4 1 EXISTING VOICE EVACUATION ALARM BOX TO BE REPLACED 2 5 8 9 S S SS SSSS CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-201 12675138 BUILDING 2631 AND 2631A NEW FIRE ALARM SYSTEM FIRST FLOOR PLAN AREAS 2 & 3 H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 E-201 KEYED CONSTRUCTION NOTES 1 NOT IN CONTRACT. FIRE SHUTTER WORK SHALL NOT BE REQUIRED BY THIS PROJECT. 2 SEE RISER DIAGRAM FOR WORK REQUIREMENT. 3 REPLACE EXISTING FIRE ALARM ANNUNCIATOR WITH A NEW LOCAL OPERATORS CENTER. PROVIDE A CUSTOM BLANK PLATE OVER EXISTING BACK BOX. PAINT TO MATCH EXISTING WALL COLOR. SEE DRAWING E-401 FOR ADDITIONAL INFORMATION. CONTACT TIM MCGEE AT WFS FOR BLANK PLATE. 4 PROVIDE A CUSTOM MADE BLANK PLATE OVER EXISTING BOX. COLOR TO MATCH EXISTING WALL. 5 PROVIDE NEW DUCT SMOKE DETECTOR WITH REMOTE TEST SWITCH. DETECTOR TO REPORT TO FACP AS SUPERVISORY CONDITION ONLY. TYPICAL ON DRAWING, SEE RISER DIAGRAM FOR TYPICAL WIRING REQUIREMENTS. 6 TAMPER SWITCH TO REPORT TO FACP AS SUPERVISORY CONDITION. FLOW SWITCH TO REPORT AS ALARM CONDITION. SEE E-401 FOR ADDITIONAL INFORMATION. 7 CARBON MONOXIDE DETECTOR. REFER TO E-401 FOR ADDITIONAL INFORMATION. 8 FANS IN THIS ROOM WITH DUCT SMOKE DETECTORS ARE ABOVE 2000 CFM AND SHALL REQUIRE FIRE ALARM SHUTDOWN. 9 PROGRAM ELEVATOR SMOKE DETECTOR TO OPERATE SMOKE VENT IN THE SHAFT. 0' 8' 16' 32' SCALE: 1/16"=1'-0" SCALE:1/16" = 1'-0"1 1ST FLOOR NEW WORK SCALE:1/8" = 1'-0"2 BUILDING 2631 MEZZANINE NEW WORK 0' 4' 8' 16' SCALE: 1/8"=1'-0" # GENERAL NOTES 1. PHASE 1, PROVIDE NEW FIRE ALARM SYSTEM. PHASE 2, REMOVE THE EXISTING FIRE ALARM SYSTEM. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL DURING THE INSTALLATION OF THE NEW SYSTEM. 2. IN UTILITY SPACES, THE USE OF EMT AS SURFACE RACEWAY IS ACCEPTABLE. IN FINISHED SPACES, PROVIDE IVORY WIREMOLD SURFACE RACEWAY. REFER TO KEYED NOTES FOR DETAILS. 3. THIS DRAWING DOES NOT SHOW THE EXISTING SPRINKLER SYSTEM. 4. PROVIDE NEW FIRE ALARM DEVICES AS INDICATED ON DRAWING. NEW DEVICES SHALL BE INSTALLED APPROXIMATELY CLOSE TO THE EXISTING FIRE ALARM DEVICES (SEE EXISTING FA SYSTEM FLOOR PLAN FOR THE EXISTING FA DEVICES LOCATIONS). 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION 20011 20012 2001520016 20045 20047 20062 20067 20065 20066 20068 202 204 206 208 210 212 214 215 218 222 224 226 227 228 230 232 240 241 242244 213 217 219 221 223 20040 225 20060 20049 20048 243 2000620005 OPEN TO BELOW OPEN TO BELOW 10013 OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW DN DN DN DN DN DN UPUP DN DN DN DN UP 1M115A 1M115DN DN 25' 40' 40' 40' BD 40' 40' 40' FF BEAM DETECTOR TYPICAL SSSSS FS FS FSTS TS TS S S S S S S S S S RF-2A D S HV-3 D S D HV-2 S RF-2 D S RF-3 D S S S S S S S S D FC-1 S D FC-2 S S FC-3 D S D FC-1 S H H FFF FFF FS TS FS TSFF FFFF F F S D FC-4 S ELEV. S F SSS F CLG.F CLG. S WALL INDICATES NEW FIRE ALARM DEVICE (TYPICAL ON DRAWNG) 1 BD BDBD BD BD ALL NEW COMBO NOTIFICATION APPLIANCES SHALL BE SPEAKER/STROBES AREA 3AREA 4 AREA 3AREA 4 S ELECTRICAL ROOM ADD NEW FCI M/N HPPFF12 NAC APPLIANCE POWER BOOSTER PANEL & TERMINAL CABINET M/N SSU00645, TC-2, 32 POINT CABINET ADD NEW FCI M/N HPPFF12 NAC APPLIANCE POWER BOOSTER PANEL & TERMINAL CABINET M/N SSU00645, TC-2, 32 POINT CABINET AREA 5 2 2 1 2 2 2 33 3 3 2 3 4 S SHAFT 5 VV25' SPEAKER A SPEAKER B CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-202 12675138 BUILDING 2631 AND 2631A NEW FIRE ALARM SYSTEM SECOND FLOOR PLANS AREAS 3, 4 & 5 H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 E-202 KEYED CONSTRUCTION NOTES 1 TAMPER SWITCH TO REPORT TO FACP AS SUPERVISORY CONDITION. FLOW SWITCH TO REPORT AS ALARM CONDITION. SEE E-401 FOR ADDITIONAL INFORMATION. 2 PROVIDE NEW DUCT SMOKE DETECTOR WITH REMOTE TEST SWITCH. DETECTOR TO REPORT TO FACP AS SUPERVISORY CONDITION ONLY. TYPICAL ON DRAWING. SEE RISER DIAGRAM FOR TYPICAL WIRING REQUIREMENTS. 3 FAN IS BELOW 2000 CFM AND SHALL NOT REQUIRED FIRE ALARM SHUTDOWN. 4 FANS IN THIS ROOM WITH DUCT SMOKE DETECTORS ARE ABOVE 2000 CFM AND SHALL REQUIRE FIRE ALARM SHUTDOWN. 5 PROGRAM ELEVATOR SMOKE DETECTOR TO ALSO TO OPERATE THE SMOKE VENT IN THE SHAFT. SCALE:1/16" = 1'-0"1 2ND FLOOR NEW WORK # 0' 8' 16' 32' SCALE: 1/16"=1'-0" BUILDING 2631A MEZZANINE GENERAL NOTES 1. PHASE 1, PROVIDE NEW FIRE ALARM SYSTEM. PHASE 2, REMOVE THE EXISTING FIRE ALARM SYSTEM. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL DURING THE INSTALLATION OF THE NEW SYSTEM. 2. IN UTILITY SPACES, THE USE OF EMT AS SURFACE RACEWAY IS ACCEPTABLE. IN FINISHED SPACES, PROVIDE IVORY WIREMOLD SURFACE RACEWAY. REFER TO KEYED NOTES FOR DETAILS. 3. THIS DRAWING DOES NOT SHOW THE EXISTING SPRINKLER SYSTEM. 4. PROVIDE NEW FIRE ALARM DEVICES AS INDICATED ON DRAWING. NEW DEVICES SHALL BE INSTALLED APPROXIMATELY CLOSE TO THE EXISTING FIRE ALARM DEVICES (SEE EXISTING FA SYSTEM FLOOR PLAN FOR THE EXISTING FA DEVICES LOCATIONS). S 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION F 3P0063 3P0062 3P0017 3P00153P0016 DN DN UP DN ROOFFF BEAM DETECTOR TYPICAL S HV-6(S) D S HV-7(R) S HV-3(S) D S HV-5(R) D S HV-7(S) D H H FS TSFF S HV-1(R) D S D HV-4(R) S D HV-1(S) S HV-4(S) D H H FS TS F FH H BD BD BD BD BD BD BD BD INDICATES NEW FIRE ALARM DEVICE (TYPICAL ON DRAWING) ADD NEW FCI M/N HPPFF12 NAC APPLIANCE POWER BOOSTER PANEL & TERMINAL CABINET M/N SSU00645, TC-2, 32 POINT CABINET AREA 5 AREA 6 AREA 4 1 2 D 1 2 3 3 V SPEAKE A, MOUNT AT 30' V SPEAKE B, MOUNT AT 30'CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-203 12675138 BUILDING 2631 NEW FIRE ALARM SYSTEM THIRD FLOOR PLAN AREAS 4, 5, & 6 H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 E-203 KEYED CONSTRUCTION NOTES 1 TAMPER SWITCH TO REPORT TO FACP AS SUPERVISORY CONDITION. FLOW SWITCH TO REPORT AS ALARM CONDITION. SEE E-401 FOR ADDITIONAL INFORMATION. 2 PROVIDE NEW DUCT SMOKE DETECTOR WITH REMOTE TEST SWITCH. DETECTOR TO REPORT TO FACP AS SUPERVISORY CONDITION ONLY. TYPICAL ON DRAWING. SEE RISER DIAGRAM FOR TYPICAL WIRING REQUIREMENTS. 3 FANS IN THIS ROOM WITH DUCT SMOKE DETECTORS ARE ABOVE 2000 CFM AND SHALL REQUIRE FIRE ALARM SHUTDOWN. 0' 8' 16' 32' SCALE: 1/16"=1'-0" SCALE:1/16" = 1'-0"1 3RD FLOOR NEW WORK # GENERAL NOTES 1. PHASE 1, PROVIDE NEW FIRE ALARM SYSTEM. PHASE 2, REMOVE THE EXISTING FIRE ALARM SYSTEM. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL DURING THE INSTALLATION OF THE NEW SYSTEM. 2. IN UTILITY SPACES, THE USE OF EMT AS SURFACE RACEWAY IS ACCEPTABLE. IN FINISHED SPACES, PROVIDE IVORY WIREMOLD SURFACE RACEWAY. REFER TO KEYED NOTES FOR DETAILS. 3. THIS DRAWING DOES NOT SHOW THE EXISTING SPRINKLER SYSTEM. 4. PROVIDE NEW FIRE ALARM DEVICES AS INDICATED ON DRAWING. NEW DEVICES SHALL BE INSTALLED APPROXIMATELY CLOSE TO THE EXISTING FIRE ALARM DEVICES (SEE EXISTING FA SYSTEM FLOOR PLAN FOR THE EXISTING FA DEVICES LOCATIONS). 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION FIRE ALARM CONTROL PANEL BATTERY CABINET GFCI E3 SERIES AMPLIFICATION TRANSPONDER PANEL BATTERY CABINET FCI M/N HPPFF12 NAC APPLIANCE POWER BOOSTER PANEL 5' - 8" CIT EQUIPMENT CIT PLYWOOD BOARD 6' - 0"7 7 5 4 9 4 2 1 10 11 3 7 6 PHONE CABLE BY CIT 1" EMT BY CONTRACTOR SEE RISER DIAGRAM 3' - 0" AREA OF WORK DOOR CEILING FLOOR 7 8 BATTERY CABINET 4 GFCI E3 SERIES AMPLIFICATION TRANSPONDER PANEL 7 7 5 TO SPEAKER A IN 101 TO SPEAKER B IN 101 TO COMMON SPEAKERS TO COMMON SPEAKERS SERVING ADDITIONAL COMMON SPEAKERSVELOCITY PANELTYPICAL TS & FS LOCATED IN RM. B0063 (1) PAIR OF 16 AWG TWISTED, NOT SHIELDED IN 3/4" EMT (1) PAIR OF 16 AWG TWISTED, NOT SHIELDED IN 3/4" EMT TSFS (2) PAIRS OF 14 AWG TWISTED, SHIELDED IN 3/4" EMT, TYPICAL 12 THE FIRE ALARM ARCHNET NETWORK CABLING RUNNING BETWEEN THE FIRE ALARM CONTROL PANEL, TRANSPONDER, LOCAL OPERATORS CENTER, AND GYM PAGING PANELS, MUST BE INSTALLED AS NOTED IN A DEDICATED RACEWAY AND MAY NOT BE INTERMINGLED WITH SLC INITIATION CIRCUITS OR SPEAKER CIRCUITS. SPEAKER CIRCUIT CABLING MAY NOT BE INSTALLED IN THE SAME RACEWAY AS SLC INITIATING CIRCUIT WIRING. MUXPAD EXISTING FIRE PUMP PANEL 13 7 7 14 TO SPEAKER B IN 112 TO SPEAKER A IN 112 CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-301 12675138 DETAILS H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 SCALE:1" = 1'-0"1 NEW FIRE ALARM EQUIPMENT ELEVATION VIEW RM B0065 E-301 KEYED CONSTRUCTION NOTES 1 NEW GFCI E3 SERIES FIRE ALARM CONTROL PANEL. "C" SIZE ENCLOSURE, 19-3/8" W X 30"H X 4-1/2" D. 2 DIGITIZE M/N 425126-0031 MUXPAD II CONTROL PANEL. 13.25"W X 9.25'H X 3.5"D. 3 CIRCUIT TO THE EXISTING CIRCUIT BREAKER FEEDING THE EXISTING FIRE ALARM CONTROL PANEL. 4 SSU00501 BATTERY CABINET, (2) FCI B-31R STANDBY BATTERIES. 22"W X 10"H X 8.81" D. 5 GFCI E3 SERIES AMPLIFICATION TRANSPONDER PANEL WITH GFCI M/N 1100-0460 ENCLOSURE. "B" SIZE ENCLOSURE, 19-3/8"W X 19-3/8"H X 4-1/2"D. 6 VELOCITI SERIES MMI-10F, MULTI-MOD TEN INPUT MONITOR MODULE IN MBB-2 ENCLOSURE. 12.25" X 9.25"W X 3.32"D (SERVING BASEMENT FLOW AND TAMPER SWITCHES). 7 1" CONDUIT & CABLES BY CONTRACTOR. TERMINATION BY WEST FIRE SYSTEMS, INC. 8 ADJACENT TO THE NEW FACP, PROVIDE A SURFACE MOUNT RECEPTACLE. CIRCUIT THE RECEPTACLE TO THE SAME CIRCUIT FEEDING THE NEW FACP. 9 FCI M/N HPPFF12 NAC APPLIANCE POWER BOOSTER PANEL. 16.7"W X 19"H X 5.2"D. PROVIDE 120V POWER CONNECTION. CIRCUIT TO THE SAME CIRCUIT FEEDING THE NEW FACP. 10 INSIDE THE FACP, PROVIDE 120VAC SURGE SUPPRESSOR, SPACE AGE ELECTRONICS INC. MODEL GFCI M/NE 120V-GT. 11 (1) 12 AWG (EARTH GROUND) IN 1" EMT TO NEAREST BUILDING STEEL. 12 THE PROJECT MANAGER TO HIRE CORNELL INFORMATION & TECHNOLOGIES (CIT) TO PROVIDE A NEW TELEPHONE CABLE. 13 PROVIDE (3) AMM-2F TO MONITOR EXISTING FIRE PUMP. ONE TO MONITOR THE PHASE REVERSAL, THE SECOND TO MONITOR RUNNING, THE THIRD TO MONITOR POWER FAILURE. PROVIDE (1) PAIR OF 16 AWG TWISTED, NOT SHIELDED IN 3/4" EMT RUNNING FROM THE THREE ADDRESSABLE MONITOR MODULES TO THE EXISTING FIRE ALARM CONTROL PANEL. 14 TAMPER SWITCH TO REPORT TO FACP AS SUPERVISORY CONDITION. FLOW SWITCH TO REPORT AS ALARM CONDITION. # 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION FIRE ALARM CONTROL PANEL B0065 AREA 1 S FHSF J J GENERATOR CONTROLLER 13 13 AREA 2 TERMINAL CABINET 10065 AREA 2 BOOSTER PANEL 10065 AREA 3 TERMINAL CABINET 10067 AREA 3 BOOSTER PANEL 10067 (1) PAIR OF 16 AWG. TWISTED, NOT SHIELDED INITIATION CIRCUT, CLASS B. TYP. FOR ALL INITIATION DEVICES (2) PAIRS OF 14 AWG THHN NOTIFICATION CIRCUIT, CLASS A. TYP. FOR ALL STROBE DEVICES 12 4 LOCAL OPERATORS CENTER 10042 S F H F S 6 2 3 8 9 2 3 8 9 1414 BASEMENT FIRST FLOOR SECOND FLOOR THIRD FLOOR 7 10 5 5 AREA 4 TERMINAL CABINET 20065 AREA 4 BOOSTER PANEL 20065 2 3 8 9 14 5 AREA 5 TERMINAL CABINET 200682 10 AREA 5 BOOSTER PANEL 20068 3 8 9 14 AREA 6 TERMINAL CABINET 3P0062 AREA 6 BOOSTER PANEL 3P0062 2 3 8 9 14 5 11 1 12 12 12 12 12 5 12 12 GYM PAGING PANEL 101 WEST GYM PAGING PANEL 112 (1) PAIR 14 TWISTED FOR CLASS A NETWORK IN 1" EMT (1) PAIR 14 THHN FOR 24 VDC POWER IN 1" EMT (1) PAIR 14 TWISTED FOR CLASS A NETWORK IN 1" EMT (1) PAIR 14 THHN FOR 24 VDC POWER IN 1" EMT (1) PAIR 14 TWISTED FOR CLASS A NETWORK RETURN IN 1" EMT COAMM-2F (1) PAIRS OF 14 AWG THHN 24 VDC FOR DETECTION POWER (1) PAIR OF 16 AWG. THHN INITIATION CIRCUT, CLASS B COMMON PATH WAY W/ (2) PAIRS OF 14 AWG TWISTED, SHIELDED SPEAKERS CIRCUIT, CLASS A. IN 3/4" EMT (2) PAIRS OF 14 AWG THHN NOTIFICATION CIRCUIT, CLASS A. TYP. FOR STROBE DEVICE S FHSF (1) 14 AWG THHN GROUND IN 3/4" EMT GYM PAGING PANEL 101 EAST (1) PAIR 14 TWISTED FOR CLASS A NETWORK IN 1" EMT (1) PAIR 14 THHN FOR 24 VDC POWER IN 1" EMT COMMON PATH WAY W/ (12) PAIRS OF 14 AWG TWISTED, SHIELDED SPEAKERS CIRCUIT, CLASS A. IN 3/4" EMT COMMON PATH WAY W/ (8) PAIRS OF 14 AWG TWISTED, SHIELDED SPEAKERS CIRCUIT, CLASS A. IN 3/4" EMT COMMON PATH WAY W/ (4) PAIRS OF 14 AWG TWISTED, SHIELDED SPEAKERS CIRCUIT, CLASS A. IN 3/4" EMT S FHSF S FHSF S FHSF S F H F S S F H F S 15JJ TS FS 10066 10066 15JJ TS FS 10065 10065 VELOCITI PANEL 5 TSFSFSFS TS TS 20066 (1) PAIR OF 16 AWG. TWISTED, NOT SHIELDED INITIATION CIRCUT, CLASS B. 15 J J TS FS 3P0062 3P0062 VELOCITI PANELFSFSTSTS 20048 (1) PAIR OF 16 AWG. TWISTED, NOT SHIELDED INITIATION CIRCUT, CLASS B. 5 10 FS TS 3P0063 (1) PAIR OF 16 AWG. TWISTED, NOT SHIELDED INITIATION CIRCUT, CLASS B. COMMON PATH WAY W/ (2) PAIRS OF 14 AWG TWISTED, SHIELDED SPEAKERS CIRCUIT, CLASS A. IN 3/4" EMT COMMON PATH WAY W/ (2) PAIRS OF 14 AWG TWISTED, SHIELDED SPEAKERS CIRCUIT, CLASS A. IN 3/4" EMT BD BD TYP. IN GYM 101 (1) PAIR OF 16 AWG. TWISTED, NOT SHIELDED INITIATION CIRCUT, CLASS B. S D AOM MR FAN (1) PAIR OF 16 AWG. TWISTED, NOT SHIELDED INITIATION CIRCUT, CLASS B. TYPICAL (1) PAIRS OF 16 AWG TWISTED UNSHIELDED SLC CIRCUIT. TYPICAL (2) PAIRS OF 14 AWG THHN FOR SUPERVISED CONNECTION/SAFETY CONNECTION. TYPICAL S D AOM MR FAN S D AOM MR FAN S D AOM MR FAN S D AOM MR FAN (1) 14 AWG THHN GROUND IN 3/4" EMT (1) 14 AWG THHN GROUND IN 3/4" EMT (1) PAIRS OF 14 AWG THHN 24 VDC FOR POWER 16 17 17 17 17 17 18 CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-401 12675138 RISER DIAGRAM H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 SCALE:1" = 1'-0"1 RISER DIAGRAM E-401 KEYED CONSTRUCTION NOTES 1 REFER TO DRAWING E-301 FOR ADDITIONAL INFORMATION. 2 FIRE ALARM TERMINAL CABINET. M/N SSU00645, TC-2, 32 POINT CABINET. 14”W X 14”H X 3.5”D. 3 FCI M/N HPPFF12, NAC APPLIANCE POWER BOOSTER PANEL. 16.7W X 19”H X 5.2D. 4 (5) PAIRS OF 16 AWG TWISTED, NOT SHIELED ADDRESSABLE CIRCUITS. (1) PAIR OF 14 AWG THHN, FOR ANNUNCIATOR POWER. (2) PAIRS OF 14 TWISTED, NOT SHIELDED FOR ANNUNCIATOR DATA. 1 1/2” EMT. 5 1” EMT & CABLES BY THE CONTRACTOR. TERMINATION BY WEST FIRE SYSTEMS, INC. 6 ENTRY LOBBY LOCAL OPERATORS CENTER (LOC.) GAMEWELL FCI E3 SERIES LOC. FCI E3BB-BAA CABINET WITH FCI E3ID3-A INNER DOOR ASSEMBLY. 19.25”W X 10”H X 3.D. 7 (1) PAIR OF 14 AWG THHN FOR 24 VDC POWER AND (2) SEPERATE PAIRS OF 14 TWISTED FOR NETWORK IN/OUT & (1) 14 AWG THHN GROUNG IN 1” EMT. SURFACE RACEWAY ON WALL SHALL BE WM2400. 8 CIRCUIT POWER BOOSTER PANEL TO NEAREST 120V RECEPTACLE CIRCUITRY. 9 INSIDE OF PANEL, PROVIDE 120V AC SURGE SUPPRESSOR, SPACE AGE ELECTRONICS INC. MODEL GFCI M/N E120V-GT. 10 (1) PAIR OF 16 AWG TWISTED, NOT SHIELDED, ADDRESSABLE CIRCUITS. 11 (3) PAIRS OF 16 AWG TWISTED, NOT SHIELDED, ADDRESSABLE CIRCUITS. 12 1” EMT COMMON PATHWAY WITH (1) PAIR OF 16 AWG TWISTED, NOT SHIELDED (INITIATION CIRCUIT, CLASS B). (2) PAIRS OF 14 AWG THHN (STROBE CIRCUITS, CLASS A). SURFACE RACEWAY TO A TYPICAL FA DEVICE SHALL BE WM700. 13 IN THE VICINITY OF THE CONTROLLER, PROVIDE A 4” X 4” J-BOX. INSIDE OF BOX, PROVIDE (1) FCI AMM-2IF MODULE TO MONITOR THE GENERATOR. 14 (1) 12 AWG (EARTH GROUND) IN 1” EMT TO NEAREST BUILDING STEEL. 15 AMM-2F IN A 4"x4" J-BOX SERVING TS OR FS. PROVIDE (1) PAIR OF 16 AWG TWISTED, NOT SHIELDED INITIATION CIRCUIT TO THE DEVICE. 16 ALSO TO PROVIDE (1) PAIR 14 AWG THHN FOR 24 VDC POWER TO THE GROUND LEVEL TEST STATION & (1) PAIR 16 AWG TWISTED UNSHIELDED INITIATING CIRCUIT TO AN AMM-2IF MODULE WHICH WILL BE INSTALLED ADJACENT TO THE GROUND LEVEL TEST STATION. 17 TAMPER SWITCH TO REPORT TO FACP AS SUPERVISORY CONDITION. FLOW SWITCH TO REPORT AS ALARM CONDITION. 18 CARBON MONOXIDE DETECTOR TO REPORT AS SUPERVISORY CONDITION WITH LOCAL SOUNDER AND DOES NOT REQUIRE THE FIRE ALARM SYSTEM TO ANNUNCIATE THE TEMPORAL 4 CODE. # MATERIAL LIST • GFCI M/N ASD-PL3 ANALOG SMOKE SENSOR HEAD WITH M/N B300-6 FLANGED BASE • GFCI M/N ATD-L3 ANALOG 135-DEGREE FT HEAT SENSOR HEAD WITH M/N B300-6 FLANGED BASE • GFCI M/N MS-7AF ANALOG DOUBLE ACTION MANUAL PULL STATION • GFCI M/N DNR ANALOG DUCT SMOKE DETECTOR COMPLETE WITH REMOTE TEST STATION, SENSOR HEAD, AND AIR SAMPLING TUBE • GFCI M/N AOM-2RF/MR-101C ANALOG OUTPUT CONTROL & TANDEM RELAY MODULE • GFCI M/N AMM-2F ANALOG SINGLE INPUT SUPERVISION MODULE • GFCI M/N SPSRL WALL MOUNTED 70VRMS COMBINATION SPEAKER/STROBE APPLIANCE • GFCI M/N SPRL WALL MOUNTED 70VRMS STAND ALONE SPEAKER APPLIANCE • GFCI M/N SPSCRL CEILING MOUNTED 70VRMS COMBINATION SPEAKER/STROBE APPLIANCE • GFCI M/N SRL WALL MOUNTED STANDALONE STROBE APPLIANCE • GFCI M/N SPSRK WALL MOUNTED WEATHERPROOF 70VRMS COMBINATION SPEAKER/STROBE APPLIANCE W/BACK BOX • FFE M/N 5000-103 SERIES REFLECTIVE BEAM SMOKE DETECTOR WITH GROUND LEVEL TEST STATION • FFE M/N 5000-031 SERIES REFLECTIVE BEAM SMOKE DETECTOR ADD-ON HEAD. • GFCI M/N CO1224 CARBON MONOXIDE DETECTOR. • GFCI GYMNASIUM PAGING PANEL (VOICE EVACUATION ALARM BOX) • FOR GYM 101 & 112, PROVIDE HYPERSPIKE TCPA-10 SPEAKERS. 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION