HomeMy WebLinkAboutADD 1_Bartels Hall Fire Alarm Replace_10-14-2020AttCORNELL UNIVERSITY BARTELS HALL FACILITIES CONTRACTS FIRE ALARM REPLACEMENT 121 HUMPHREYS SERVICE BUILDING ITHACA, NEW YORK 14853-3701 ADDENDUM NO. 1 October 14, 2020 This Addendum contains changes to the requirements of the Contract Documents and Specifications. Such changes are to be incorporated into the Construction Documents and shall apply to the work with the same meaning and force as if they had been included in the original document. Wherever this Addendum modifies a portion of a paragraph of the specifications or a portion of any Drawing, the remainder of the Paragraph or Drawing shall remain in force. NOTE: Provisions of all Contract Documents apply. Item 1. Attached is the Pre-Bid Sign-in Sheet for reference only. DRAWINGS Item 2. Drawing E-001, General Notes ADD 18.0 The Basis of Design for this project is a Gamewell/FCI E3 Series network addressable fire control unit and UL listed peripheral devices as noted on Drawing E-401, Material List. If another fire alarm manufacturer is specified other than the Basis of Design, the fire alarm supplier shall provide onsite end user training for Cornell University’s fire alarm technicians, as well as testing and inspection personnel. Item 3. Below is the PreBid Documentation BOX link: “Bartels Hall Fire Alarm Replacement Pre-Bid Walkthrough & Addendum Items”: https://cornell.box.com/s/33rpec6nf0vg5vqnxhaulb32cbuly3re Item 4. DELETE Drawing E-100 in its entirety. REPLACE with revised E-100, attached. Item5. DELETE Drawing E-101 in its entirety. REPLACE with revised E-101, attached. Item 6. DELETE Drawing E-102 in its entirety. REPLACE with revised E-102, attached. Bartels Hall Fire Alarm Replacement Addendum No. 1 October 14, 2020 Page 2 Item 7. DELETE Drawing E-103 in its entirety. REPLACE with revised E-103, attached. Item 8. RFI Questions and Clarifications See attached RFI Log (Items 1 – 3) Attachments: Pre-Bid Sign-in Sheet Drawings: E-100, E-101, E-102, E-103 RFI Log (Items 1-3) ****END OF ADDENDUM**** PROJECT: Bartels Hall Fire Alarm Replacement DATE: October 8, 2020 via Zoom Meeting PRE-BID MEETING 9:00AM Name Firm E-Mail Address Telephone Fax # Hung Tran Cornell-Facilities Engineering hpt4@cornell.edu 607-279-3524 Sherrie Joseph Cornell - Facilities Contracts sam7@cornell.edu Wendy Hackett Cornell - Facilities Contracts wjh6@cornell,edu 607-255-0120 607-254-4567 Matt Labosky Blanding Electric mlabosky@blandingelectric.com Jon Rigdon Matco Electric jrigdon@matcoelectric.com Matt McDonald O'Connell Electric matthew.mcdonald@oconnellelectri.com Deb Melanson Cornell - Project Management dem5@cornell.edu Dan Smith John Mills Electric Tim McGee West Fire Systems, Inc.tmcgee@westfiresystems.com John Whitmore Schueler-Haas Electric jwhitmore@schuler-haas.com Kelly Davis Cornell - eBuilder Support kmu2@cornell.edu 1-888-288-5717 Chris Kiehle Cornell University - SCL cak226@cornell.edu UP UPUP UPUP B16 B18 B20 B22 B24 B26 B28 B30 B32 B34 B36 B38 B0027 B0026 B0042 B17 B21 B23 B0028 B31 B33 B39 B0046 B0001B0066 B0063 B0053 B0065 B0040 B07 B07A B0068 B0069 B0062 B0061 B06 B06A B0052 B01 B01A B0003 B0004 B0002 B0060 B46A B46 B46C B46D B51 B42 B47B B47A B49 B44 B40 B0055 B40A B0056 B45 B41 B43 B46B B47C B47 B0064 B0054 B0031 B0030 B0051 B07B B07C B0021 B0022 B0023 B0025 B0024 B0020 B0067 B0029 B0020A B0024A B0063 B0053 B0065 B0062 B0061 B0052 B0002 B0060 B0064 B0054 B0051FS S S S S S S S S S S S S S S S S S S S S SS S S S S FFFFFFS FF F FFROLLING DOOR S S S H H ELEV.FF E-100 1 F WP S ELEV. MECH. F S S S S S FF F F F S MAIN ELECTRIC ROOM INDICATES EXISTING SPRINKLER HEAD (TYPICAL ON DRAWING) INDICATES EXISTING FIRE ALARM DEVICE (TYPICAL ON DRAWING) ALL COMBO NOTIFICATION APPLIANCES ARE SPEAKER/STROBE DEVICES TS TS TS TS FS FS FS FS TS EXISTING FIRE ALARM CONTROL PANEL. SEE PHOTO. EXISTING VOICE EVACUATION ALARM BOX. SEE PHOTO CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-100 12675138 BUILDING 2631 EXISTING AND PHASE 2 BASEMENT FIRE ALARM PLAN H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 0' 4' 8'16' SCALE: 1/8"=1'-0" SCALE:1/16" = 1'-0"2 FULL BASEMENT PLAN 0' 8' 16' 32' SCALE: 1/16"=1'-0" GENERAL NOTES 1. PHASE 1, PROVIDE NEW FIRE ALARM SYSTEM. PHASE 2, REMOVE THE EXISTING FIRE ALARM SYSTEM. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL DURING THE INSTALLATION OF THE NEW SYSTEM. 2. PHASE 2, REMOVE EXISTING FIRE ALARM DEVICES AND ASSOCIATED WIRING AND RACEWAYS COMPLETELY BACK TO SOURCE. PROVIDE ELECTRICAL IVORY BLANK PLATES OVER EXISTING BACK BOXES. SCALE:1/8" = 1'-0"1 PARTIAL BASEMENT PLAN ROOM B0064 -FIRE ALARM PANEL & VOICE EVACUATION ALARM BOX 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION 122A 122A 102 10065 10045 10021 10011 103B 103A 103 10060 10061 108 10022 10066 110 10047 112D 112C 112B 10067 112A 101 10043 10044 10003 1000410050 10012 10042 10041 10001 10002 112 10052 10040 1000810007 1000610005 10053 10051 10046 10062 DISPLAY CASECONCESSION STAND122 104 106 10064 10048 SEE BASEMENT PLAN 10014 112E 112F 112G UP UPDN UP UP DN DN DN DN UP DNUP UP UP UP DN UP UP UP UPUPUP10068 115A 115B 115 10054 10015 10014 UP UP 1M12 DN BUILDING 2631A FIRST FLOOR LOCATION OF MEZZANINE FF S S S F FFF S S J FS J FS J FS J FS S FIRE SHUTTER TYPICAL J FIRE SHUTTER S S S S J FIRE SHUTTERFF H S FSTS H FA TERMINAL BOX S S S S ELEV. F F S SFAA EXISTING FA ANNUNCIATION PANEL. SEE PHOTO. S S S S S S S S S S S S S S S S S S F FF F FF F F SSSS D D F F FJ FIRE SHUTTER FF S S S S FF S S F FF F F WG WG F WG S H FS TS H S S EXISTING SPRINKLER HEAD (TYPICAL ON DRAWING) WG INDICATES EXISTING SPRINKLER HEAD (TYPICAL ON DRAWING) INDICATES EXISTING FIRE ALARM DEVICE (TYPICAL ON DRAWING)WG WG ALL COMBO NOTIFICATION APPLIANCES ARE HORNS/STROBES EXISTING VOICE EVACUATION ALARM BOX EXISTING VOICE EVACUATION ALARM BOX EXISTING VOICE EVACUATION ALARM BOX EXISTING FIRE DEPARTMENT VOICE EVACUATION ALARM BOX. TO BE REMOVED (PHASE 2) EXISTING KNOCK BOX LYNAH RINK 1 ALL COMBO NOTIFICATION APPLIANCES IN BARTELS ARE SPEAKER/STROBE DEVICES CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-101 12675138 BUILDING 2631 AND 2631A EXISTING AND PHASE 2 FIRST FLOOR FIRE ALARM PLAN H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 SCALE:1/16" = 1'-0"1 1ST FLOOR GENERAL NOTES 1. PHASE 1, PROVIDE NEW FIRE ALARM SYSTEM. PHASE 2, REMOVE THE EXISTING FIRE ALARM SYSTEM. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL DURING THE INSTALLATION OF THE NEW SYSTEM. 2. PHASE 2, REMOVE EXISTING FIRE ALARM DEVICES AND ASSOCIATED WIRING AND RACEWAYS COMPLETELY BACK TO SOURCE. PROVIDE ELECTRICAL IVORY BLANK PLATES OVER EXISTING BACK BOXES. SCALE:1/8" = 1'-0"2 BUILDING 2631 MEZZANINE 0' 8' 16' 32' SCALE: 1/16"=1'-0" 0' 4' 8' 16' SCALE: 1/8"=1'-0" FA ANNUNCIATION PANEL E-101 KEYED DEMOLITION NOTES 1 REMOVE EXISTING VOICE EVACUATION ALARM BOX AND ASSOCIATED DEVICES AND WIRING COMPLETELY. PROVIDE A WHITE BLANK PLATE OVER EXISTING BACK BOX. # 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION 20011 20012 2001520016 20045 20047 20062 20067 20065 20066 20068 202 204 206 208 210 212 214 215 218 222 224 226 227 228 230 232 240 241 242244 213 217 219 221 223 20040 225 20060 20049 20048 243 2000620005 OPEN TO BELOW OPEN TO BELOW 10013 OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW DN DN DN DN DN DN UPUP DN DN DN DN UP 1M115A 1M115DN DN V V40'40' 40'40' V V 40' 40' 40' BD BD BD40' 40'BD BD BD 40' FF BEAM DETECTOR TYPICAL SSSSS FS FS FSTS TS TS S S S S S S S S S D S D S D S D S D S S S S S S S S D S D S S D S D S H H FFF FFF FS TS FS TSFF FFFF F F S D S SHAFT S ELEV. S F SSS F CLG.F CLG. S EXISTING SPRINKLER HEAD (TYPICAL ON DRAWNG) WALL INDICATES EXISTING FIRE ALARM DEVICE (TYPICAL ON DRAWNG) ALL COMBO NOTIFICATION APPLIANCES ARE HORNS/STROBES SPEAKER (TYPICAL) ALL COMBO NOTIFICATION IN BARTELS APPLIANCES ARE SPEAKER/STROBE DEVICES 0' 8' 16' 32' SCALE: 1/16"=1'-0"CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-102 12675138 BUILDING 2631 AND 2631A EXISTING AND PHASE 2 SECOND FLOOR FIRE ALARM PLAN H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 SCALE:1/16" = 1'-0"1 2ND FLOOR BUILDING 2631A MEZZANINE GENERAL NOTES 1. PHASE 1, PROVIDE NEW FIRE ALARM SYSTEM. PHASE 2, REMOVE THE EXISTING FIRE ALARM SYSTEM. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL DURING THE INSTALLATION OF THE NEW SYSTEM. 2. PHASE 2, REMOVE EXISTING FIRE ALARM DEVICES AND ASSOCIATED WIRING AND RACEWAYS COMPLETELY BACK TO SOURCE. PROVIDE ELECTRICAL IVORY BLANK PLATES OVER EXISTING BACK BOXES. 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION 3P0063 3P0062 3P0017 3P00153P0016 DN DN UP DN ROOFFF BD BD BD BD BD BD BEAM DETECTOR TYPICAL VVVV VVVV S WP S WP STAIR VENT SHAFT VENT SMOKE HATCH TYPICAL S WP S WP STAIR VENT SHAFT VENT S WP S WP HOISTWAY SHAFT VENT S D S D S D S D S D H H FS TSFF S D S D S D S D H H FS TS F FBDBD H H INDICATES EXISTING SPRINKLER HEAD (TYPICAL ON DRAWING) INDICATES EXISTING FIRE ALARM DEVICE (TYPICAL ON DRAWNG) SPEAKER (TYPICAL) 1 1 1 1 1 1 ALL COMBO NOTIFICATION IN BARTELS APPLIANCES ARE SPEAKER/STROBE DEVICES CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 554 CAMPUS ROAD BARTELS HALL FIRE ALARM REPLACEMENT E-103 12675138 BUILDING 2631 EXISTING AND PHASE 2 THIRD FLOOR FIRE ALARM PLAN H. TRAN JD 2631, 2631A SEPTEMBER 18, 2020 SCALE:1/16" = 1'-0"1 3RD FLOOR 0' 8' 16' 32' SCALE: 1/16"=1'-0" GENERAL NOTES 1. PHASE 1, PROVIDE NEW FIRE ALARM SYSTEM. PHASE 2, REMOVE THE EXISTING FIRE ALARM SYSTEM. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL DURING THE INSTALLATION OF THE NEW SYSTEM. 2. PHASE 2, REMOVE EXISTING FIRE ALARM DEVICES AND ASSOCIATED WIRING AND RACEWAYS COMPLETELY BACK TO SOURCE. PROVIDE ELECTRICAL IVORY BLANK PLATES OVER EXISTING BACK BOXES. E-103 KEYED DEMOLITION NOTES 1 REMOVE EXISTING DETECTOR AND ASSOCIATED WIRING COMPLETELY BACK TO SOURCE. MODIFY VENT TO BE OPERATED MANUALLY. # 1 06/29/20 ISSUE FOR DD REVIEW 2 08/14/20 ISSUE FOR 50% REVIEW 3 09/18/20 ISSUE FOR CONSTRUCTION Date: October 14, 2020 RFI Form RFI/Page/ Response Dwg./Spec./Rep.Section/Design Team Index Number Paragraph/Topic RFI Response 1 General Ceiling Types & Heights Please provide ceiling Types and Heights for each area. If I remember correctly the Common areas are all sheetrock ceilings. See Addendum No. 1, Item 3. See floor plans, reflected ceiling plans (A151, A152, A153, A154, A155, 2631A_Friedman_Ceiling Plan) and ceiling photos. 2 General EMT vs Wiremold Please provide Locations of Utility area's and any other areas where EMT can be used. Will it be allowed in open bar joist ceilings like Rooms 101, 112 and 115? If so will be have to paint EMT to match ceiling? See Addedum No. 1, Items 4 thru Item 7. 3 General Divided 2400 Wiremold Can Divided 2400 Wiremold be utilized to carry the initiating and strobe circuit on one side & the speaker circuit on the other side? The SLC initiating circuit and the 70Vrms speaker circuits cannot reside in the same raceway. A split 2400 Series with the SLC initiating circuit on one side and the 70Vrms speaker circuit on the other side will work. You can run the strobe circuit and 70Vrms speaker circuits in the same raceway. You can run the strobe circuit and SLC initiating circuits in the same raceway. PROJECT: Bartels Hall Fire Alarm Replaceme