HomeMy WebLinkAboutCornell Store ADA entrance DrawingsT(RHC-1-19) &(TB-1-19) (TB-1-19)(RHC-1-19) (AHU) (RH-20) (1-1/4" HS) (1-1/4" HR) (3/4" HS) (3/4" HR)T5412316DATE:JOB NO:REVDATE :DRAWNDESCRIPTION :SCALE:DRAWN BY:ALL DRAWINGS AND SPECIFICATIONS ARE THEPROPERTY OF THE ARCHITECT, AND SHALL BE USEDONLY ON THE JOB DESIGNATED. COPYRIGHTCTHE CONTRACTOR SHALL VERIFY ALL DIMENSIONSAT THE SITE AND PROMPTLY NOTIFY THEARCHITECT IN WRITING OF ANY DISCREPANCIES.No :BY :HOLMES KING KALLQUIST& Associates, Architects, LLP 575 North Salina Street, Syracuse, NY 13208 Ph: (315) 476 - 8371 Fax: (315) 476 - 5420www.hkkarchitects.com CORNELL CAMPUS STOREHO PLAZA ACCESSIBLE ENTRANCE ITHACA, NY 14853 1904603/23/2020100% CONDOCIT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF AN ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF ALTERED, THE ALTERING ENGINEERSHALL AFFIX HIS SEAL AND THE NOTATION 'ALTERED BY' FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION.JRSAS NOTEDM0.1LEGEND, GENERALNOTES, AND PARTIALFLOOR PLANEXISTING LINEAR SLOT DIFFUSER AND ASSOCIATED DUCTWORK TOREMAIN.RE-BALANCE EXISTING LINEAR SLOT DIFFUSER TO 400 CFM.RE-BALANCE EXISTING LINEAR SLOT DIFFUSER TO 1800 CFM.EXISTING DDC TEMPERATURE SENSOR TO REMAIN.EXISTING THERMOSTAT TO REMAIN.BALANCE EXISTING VAV TERMINAL TO 155 CFM (MINIMUM/HEATING)AND 400 CFM (MAXIMUM/COOLING). BALANCE HOT WATER FLOW TO 1GPM.1KEYED NOTES:A. COORDINATE ALL TESTING, ADJUSTING AND BALANCING WORK WITHBUILDING OPERATIONS PERSONNEL AND THE CORNELL UNIVERSITY PROJECTMANAGER.GENERAL DRAWING NOTES:2345(10")(10x8)(10x8)EQUIP-#TLEGENDSYMBOLDESCRIPTIONABBR.VD14VOLUME DAMPERVDROUND DUCT (SIZE IN INCHES)14ØWALL MOUNTED TEMPERATURE SENSOR/TEM-EXISTING DUCTWORK TO REMAIN(SINGLE LINE / DOUBLE LINE)APPROXIMATE SIZES SHOWN IN PARENTHESIS-EXISTING PIPING TO REMAINAPPROXIMATE SIZES SHOWN IN PARENTHESIS-CUBIC FEET PER MINUTECFMEXISTING GRILLE / REGISTER / DIFFUSER TO REMAIN-HWSHWRHOT WATER SUPPLYHWSHOT WATER RETURNHWRAIR HANDLING UNITAHUSUPPLY AIRSAKEYED NOTE REFERENCE:REFERS TO CORRESPONDING NUMBERON RESPECTIVE DRAWING OR DETAIL-THESE ARE STANDARD SYMBOLS AND ABBREVIATIONS AND MAY NOT APPEAR ON THEPROJECT DRAWINGS. HOWEVER, WHEREVER THE SYMBOL OR ABBREVIATION APPEARSON THE PROJECT DRAWINGS, THE ITEM SHALL BE FURNISHED AND INSTALLED.NOTE:6T:\_Project Files\Holmes King Kallquist\Cornell Ho Plaza Bookstore - 19075\Design\Mechanical\M0.1 Floor Plan.dwg, 3/18/2020 1:48:18 PM, _AutoCAD PDF (High Quality Print).pc3