Loading...
HomeMy WebLinkAboutThurston Ave 534 Zeta Psi Bathroom Renovations INDEXED PLANSbeardsley project number:Set no:Owner Beardsley Architects + Engineers Filename:To the best of our knowledge, information and belief these documents have been prepared in accordance with the requirements of: 1. Building Code of New York State 2. Energy Conservation Construction Code of New York State 3. NYS Education Department Requirements 4. NYS Department of Labor Industrial Code Rule 56 (NYCRR 56). It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter an item in any way. If an item bearing the seal of an architect is altered, the altering architect shall affix to his item the seal and the notation "ALTERED BY" followed by his signature and the date of such alteration, and a specific description of the alteration. 64 South Street Auburn, NY 13021 315.253.7301 Architect + Engineer Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © 4/13/2020 11:13:04 AM C:\Projects\BEAR-A-19100-V2018_nhavrish.rvt04.15.2020 19100Zeta Psi Bathroom Renovations Cornell University 534 Thurston Avenue Ithaca, NY 14850 2020 DRAWING LIST NUMBER NAME ALL TRADES G-000 COVER SHEET G-001 ABBREVIATIONS, SYMBOLS & GENERAL NOTES G-002 DOOR SCHEDULE, SPECIFICATIONS, TOILET ROOM ACCESSORIES & DETAILS G-003 PLUMBING SPECIFICATIONS, SCHEDULES AND DETAILS G-004 HVAC & FIRE SUPPRESSION SPECIFICATIONS ARCHITECTURE A-001 WALL SCHEDULE A-101 FIRST FLOOR PLAN A-102 SECOND FLOOR PLANS A-103 THIRD FLOOR PLAN A-104 REFLECTED CEILING PLANS A-430 INTERIOR ELEVATIONS A-701 ROOM FINISH SCHEDULE AND DETAILS PLUMBING P-101 DETAILS AND SCHEMATICS P-102 DETAILS AND SCHEMATICS ZETA PSI FRATERNITY HOUSE 534 THURSTON AVENUE PLAN NORTH COLUMN LINE GENERAL ANNOTATION 1 0 0 REVISION INDICATOR REFERENCE LEVEL ROOM NAME XXXXX XXX ROOM IDENTIFIER 101A DOOR IDENTIFIER W1 F WALL IDENTIFIER WW WINDOW AND VISION PANEL IDENTIFIER L1 LOUVER IDENTIFIER E1 EQUIPMENT IDENTIFIER 6024.L CASEWOR IDENTIFIER F1 TYP FURNITURE IDENTIFIER ?KEYNOTE INDICATOR (KEYNOTES STARTING WITH A 'D' ARE FOR DEMOLITION) SECTIONS AND DETAIL REFERENCES SCALE:A PLAN/DETAIL TITLE 1/8" = 1'-0" PLAN/DETAIL CALLOUTSA101 1 SIM CALLOUT NUMBER SPECIAL NOTES DRAWING NUMBER 1 A101 SIM SECTION MARK SECTION NUMBER (DOUBLE LETTERS FOR BUILDING SECTIONS) DRAWING NUMBER HEIGHT INDICATOR EXTERIOR ELEVATIONA ELEVATION LETTER DRAWING NUMBER - INTERIOR ELEVATIONB ELEVATION LETTER(S) DRAWING NUMBER - A D C 1 A101 SIM DETAIL MARK DETAIL NUMBER SPECIAL NOTES DRAWING NUMBER 10'-2 3/8"7 PT-1 CEILING IDENTIFIER EARTH (UNDISTURBED) STONE, GRAVEL CONCRETE PRE-CAST CONCRETE CONCRETE MASONRY UNITS EARTH (COMPACTED) GYPSUM WALL BOARD GLASS PLYWOOD WOOD (FINISHED) WOOD SHIMS (NON-CONT.) BRICK WOOD BLOCKING (CONT.) (NOM. DIMS.) BATT INSULATION 2 6 PARTICLE BOARDRIGID INSULATION ACOUSTIC TILE CARPET STEEL EXISTING GENERAL ABBREVIATIONS SYMBOLS LEGEND MATERIALS LEGEND Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. ©Filename:Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE no. revision description by date 4/13/2020 11:13:06 AMC:\Projects\BEAR-A-19100-V2018_nhavrish.rvtALL TRADES Cornell UniversityG-001 04.15.2020 ABBREVIATIONS, SYMBOLS & GENERAL NOTESZeta Psi Bathroom Renovations534 Thurston Avenue Ithaca, NY 14850NRH 19100 MAR NRH 2020 SPKR SPEAKER SQ SQUARE SS STAINLESS STEEL ST STORM WATER STA STATION STD STANDARD STL STEEL STO STORAGE STRUCT STRUCTURAL SURF SURFACE SUSP SUSPENDED SWD STORMWATER DRAIN SYM SYMMETRY (ICAL) SYS SYSTEM T TREAD(S) T&G TONGUE AND GROOVE T/ TOP OF TB TACKBOARD, TOWEL BAR TECH TECHNOLOGY, TECHNICAL TEL TELEPHONE TEMP TEMPERATURE TERR TERRAZZO TG TEMPERED GLASS THK THICKNESS THR THRESHOLD THRU THROUGH TOC TOC OF CURB TOS TOP OF STEEL TOW TOP OF WALL TPD TEMPERED TPTN TOILET PARTITION TRD TRENCH DRAIN TTD TOILET TISSUE DISPENSER TV TELEVISION TYP TYPICAL U HEAT TRANSFER COEFFICIENT UC UNDERCUT UG UNDERGROUND UH UNIT HEATER UL UNDERWRITERS LABORATORIES UNF UNFINISHED UNO UNLESS NOTED OTHERWISE UR URINAL UTL UTILITY UV UNIT VENTILATOR V VOLT VAR VARIES VAT VINYL ASBESTOS TILE VB VAPOR BARRIER VCT VINYL COMPOSITION TILE VENT VENTILATION VERT VERTICAL VEST VESTIBULE VOC VOLATILE ORGANIC COMPOUND VOL VOLUME VP VISION PANEL VRB V VENTED RUBBER BASE VWC VINYL WALL COVERING W WATT W/ WITH W/O WITHOUT WB WHITEBOARD WC WATER CLOSET, WALL COVERING WD WOOD WF WIDE FLANGE WG WIRE GLASS WH WATER HEATER, WALL HUNG WI WROUGHT IRON WM WIRE MESH WP WATERPROOF WR WATER RESISTANT WSCT WAINSCOT WT WEIGHT WV WATER VALVE WWM WELDED WIRE MESH YD YARD MIN MINIMUM MISC MISCELLANEOUS MLD MOLDING MO MASONRY OPENING MOD MODULAR MT MOUNT(ED)(ING) MTH MOUNTING HEIGHT MTL METAL MTP METAL TOILET PARTITION MULL MULLION MWC MULTI-COLOR WALL COATING MWK MILLWORK N/A NOT APPLICABLE N/F NEAR FACE NEG NEGATIVE NIC NOT IN CONTRACT NO OR # NUMBER NOM NOMINAL NTS NOT TO SCALE O/A OVERALL O/F OUTSIDE FACE O/O OUT TO OUT OC ON CENTER OD OUTSIDE DIAMETER OH OVERHEAD OHE OVERHEAD ELECTRIC OHE&T OVERHEAD ELECTRIC AND TELEPHONE OPNG OPENING OPP OPPOSITE ORD OVERFLOW ROOF DRAIN OUT OUTLET P/L PROPERTLY LINE PA PUBLIC ADDRESS PART PARTIAL PBD PARTICLE BOARD PC PRECAST CONCRETE, PLUMBING CONTRACTOR PCL PAVEMENT CUT LINE PE PORCELAIN ENAMEL PEND PENDANT PERC PERCOLATION PERF PERFORATED PG PLATE GLASS PIV POST IINDICATING VALVE PL PLATE PLA PLASTIC PLAM PLASTIC LAMINATE PLAS PLASTER PNL PANEL PNT PAINT POB POINT OF BEGINNING POS POSITIVE PP POWER PANEL PR PAIR PREFAB PREFABRICATED PROP PROPERTY PT POINT, PRESSURE TREATED PTD PAPER TOWEL DISPENSER PTN PARTITION PVC POLYVINYL CHLORIDE PVMT PAVEMENT PWD PLYWOOD PWR POWER QT QUARRY TILE QTB QUARRY TILE BASE QTR QUARTER QTY QUANTITY R RISER, RADIUS, HEAR RESISTANCE RA RETURN AIR RAD RADIATOR RC ROOFING CONTRACTOR, ROOF CUT LOCATION RCP REFLECTED CEILING PLAN RD ROOF DRAIN RECT RECTANGLE REF REFERENCE, REFRIGERATOR REG REGISTER REINF REINFORCING REL RELOCATE REM REMOVE, REMOVABLE REQD REQUIRE(D) REQMT REQUIREMENT RESIL RESILIENT REV REVISION, REVISE(D) RH ROOF HATCH, ROBE HOOK RIV ROOF INTAKE VENTILATOR RL ROOF LEADER RM ROOM RO ROUGH OPENING ROW RIGHT OF WAY RT RESILIENT TILE RTU ROOF TOP UNIT RUB RUBBER RV ROOF VENT RW RESCUE WINDOW S/L SLORM LOUVER S/P SOUNDPROOF SAFB SOUND ATTENUATION FIRE BLANKETS SAN SANITARY SCH SCHEDULE SD SOAP DISPENSER SDR SUB DRAIN SECT SECTION SF SQUARE FEET, SQUARE FOOT SGT STRUCTURAL GLAZED TILE SHT SHEET SHTH SHEATHING SHWR SHOWER SIM SIMILAR SKL SKYLIGHT SL SLEEVE SLL SURVEY LIMIT LINE SM SHEET METAL SND SANITARY NAPKIN DISPENSER SNDU SANITARY NAPKIN DISPOSAL UNIT SOG SLAB ON GRADE SPEC SPECIFICATION EG EXHAUST GRILLE EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRIC(AL) ELEV ELEVATOR EM EMERGENCY ENC ENCLOSURE EOS EDGE OF SLAB EQP EQUIPMENT ETC ET CETERA ETR EXISTING TO REMAIN EU EXIT UNITS EW EACH WAY EWC ELECTRIC WATER COOLER EWEF EACH WAY EACH FACE EWH ELECTRIC WATER HEATER EX EXISTING EXC EXCAVATION EXH EXHAUST EXP EXPAND, EXPANSION EXT EXTERIOR F/P FIREPROOF F/S FOOTING STEP FA FIRE ALARM FBO FURNISHED BY OTHERS FD FLOOR DRAIN FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FFE FINISHED FLOOR ELEVATION FG FINISH GRADE FGL FIBERGLASS FHC FIRE HOSE CABINET FIN FINSIH(ED) FIXT FIXTURE FL FLOOR FLG FLANGE FLOUR FLOURESCENT FLX FLEXIBLE FND FOUNDATION FOC FACE OF CONCRETE FOF FACE OF FINISH FOM FACE OF MASONRY FOS FACE OF STUD FP FIRE PROTECTION FPL FIREPLACE FPM FEET PER MINUTE FR FRAME(D)(ING) FRT FIRE RETARDENT FS FAR SIDE FT FEET OR FOOT FTG FOOTING FTR FIN TUBE RADIATION FUR FURRED, FURRING FURN FURNISH, FURNITURE GA GAGE, GAUGE GAL GALLON GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GDBM GRADE BEAM GL GLASS, GLAZING GND GROUND GPH GALLONS PER HOUR GPM GALLONS PER MINUTE GRA GRANITE GRD GRADE/GRADING GVL GRAVEL GWB GYPSUM WALLBOARD GYP GYPSUM HB HOSE BIB HC HANDICAPPED HD HEAD HDW HARDWARE HEX HEXAGONAL HM HOLLOW METAL HOR HORIZONTAL HPL HIGH PRESSURE LAMINATE HR HANDRAIL HT HEIGHT HV HEATING AND VENTILATING UNIT HVAC HEATING, VENTILATION AND AIR CONDITIONING HW HOT WATER HWD HARDWOOD HWR HOT WATER RETURN HYD HYDRANT I/F INSIDE FACE ID INSIDE DIAMETER INCAN INCANDESCENT INCL INCLUDE(D), INCLUDING INSUL INSULATION INT INTERIOR INV INVERT IPS IRON PIPE SIZE JAN JANITOR'S CLOSET JST JOIST JT JOINT KD KNOCKDOWN KIP ONE THOUSAND POUNDS L LONG, LENGTH LAB LABORATORY LAM LAMINATE(D) LAV LAVATORY LB LAG BOLT LBRG LOAD BEARING LF LINEAL FEET LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LP LIGHTING PANEL LT LIGHT LTG LIGHTING LVR LOUVER MACH MACHINE MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MED MEDIUM MEZZ MEZZANINE MFR MANUFACTURER MH MANHOLE @ AT A/C AIR CONDITIONING AB ANCHOR BOLT AC ABOVE COUNTER ACT ACOUSTIC CEILING TILE ACU AIR CONDITIONING UNIT AD ACCESS DOOR ADJ ADJACENT ADJT ADJUSTABLE AFF ABOVE FINISH FLOOR AFG ABOVE FINISH GRADE AHJ AUTHORITIES HAVING JURISDICTION AHU AIR HANDLING UNIT AL OR ALUM ALUMINUM ALT ALTERNATE ANOD ANNODIZED AP ACCESS PANEL APC ACOUSTIC PANEL CEILING APPROX APPROXIMATE, APPROXIMATELY ARCH ARCHITECT(URAL) ASB ASBESTOS ASPH ASPHALT AWP ACOUSTIC WALL PANEL B/ BOTTOM OF B/B BACK-TO-BACK BAT BATTEN BBD BOILER BLOW-DOWN LINE BD BOARD BDRM BEDROOM BIT BITUMINOUS BLK BLOCK BLKG BLOCKING BM BENCH MARK BOC BOTTOM OF CURB BOT BOTTOM BOW BOTTOM OF WALL BPL BASE PLATE BRDG BRIDGING BRG BEARING BS BOTH SIDES BSMT BAESMENT BTWN BETWEEN BUR BUILT-UP ROOFING BVL BEVELED C/C CENTER TO CENTER CB CATCH BASIN, CHALK BOARD CEM CEMENT, CEMENTITIOUS CEN CENTER CF CUBIC FEET CFM CUBIC FEET PER MINUTE CFMF COLD FORM METAL FRAMING CFS CUBIC FEET PER SECOND CG CORNER GUARD CI CAST IRON CIP CAST-IN-PLACE CJ CONTROL JOINT CK CAULK(ING) CL CENTERLINE CLF CHAIN LINK FENCE CLG CEILING CLL CONTRACT LIMIT LINE CLO CLOSET CLR CLEAR, CLEARANCE CLRM CLASSROOM CMP CORRUGATED METAL PIPE CMT CERAMIC MOSAIC TILE CMU CONCRETE MASONRY UNIT CO CLEAN OUT COL COLUMN COMP COMPACT(ED) CONC CONCRETE CONF CONFERENCE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CPT CARPET CRS COURSE(S) CST CAST STONE CT CERAMIC TILE CTG COATING CTR COUNTER CTSK COUNTERSUNK SCREW CU COPPER CUH CABINET UNIT HEATER CUL CULVERT CUSH CUSHION(ED) CUST CUSTODIAL CW COLD WATER, CLOTHES WASHER STC SOUND TRANSMISSION CLASS D DEPTH DBL DOUBLE DEG DEGREE DEMO DEMOLISH/DEMOLITION DEP DEPRESS DEPT DEPARTMENT DF DRINKING FOUNTAIN DI DROP INLET DIA OR ø DIAMETER DIAG DIAGONAL DIFF DIFFERENCE DIM DIMENSION DISP DISPENSER DL DRAIN LINE DMT DEMOUNTABLE DN DOWN do DITTO DP DAMPPROOFING DS DOWNSPOUT DT DRAIN TILE DTL DETAIL DWG DRAWING DWL DOWEL DWR E/F DRAWER EACH FACE EA EACH EB EXPANSION BOLT EF EXHAUST FAN GENERAL DEMOLITION NOTES A THESE GENERAL NOTES APPLY TO EXISTING SPACES AND BUILDING CONSTRUCTION AFFECTED BY THE WORK. B THE DEMOLITION DRAWINGS ARE INTENDED AS A SUMMARY OF THE DEMOLITION, BUT MAY NOT REPRESENT ALL OF THE DEMOLITION REQUIRED TO COMPLETE THE WORK. THE DEMOLITION DRAWINGS AND THE REMAINDER OF THE CONSTRUCTION DOCUMENTS ARE COMPLEMENTARY, AS ADDITIONAL INFORMATION REQUIRED TO COMPLETE THE DEMOLITION MAY BE INDICATED THROUGHOUT. C DEMOLITION REQUIRED TO COMPLETE THE WORK, BUT NOT INDICATED, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. D DEMOLITION OF MECHANICAL, ELECTRICAL, AND PLUMBING ELEMENTS REQUIRED BY THE GENERAL DEMOLITION, BUT NOT INDICATED, SHALL BE COMPLETED BY THE APPROPRIATE TRADE CONTRACTORS. EACH TRADE CONTRACTOR SHALL COORDINATE DEMOLITION WITH EACH OTHER AND WITH THE SCOPE OF THE FINISHED WORK. E WHERE NEW FINISHES ARE TO BE APPLIED REMOVE ABANDONED, NON-FUNCTIONING ITEMS, SUCH AS SURFACE MOUNTED CONDUIT, RACEWAYS, JUNCTION BOXES, CLIPS, BRACKETS, FASTENERS, ETC. MECHANICAL, ELECTRICAL, AND PLUMBING ELEMENTS SHALL BE REMOVED BY THE APPROPRIATE TRADE CONTRACTORS, UNLESS OTHERWISE INDICATED OR DIRECTED. EXISTING FINISHES TO REMAIN SHALL BE PATCHED TO MATCH ADJACENT MATERIALS FOLLOWING REMOVALS. F SHOULD CONFLICTS EXIST WITHIN THE CONSTRUCTION DOCUMENTS, VERIFY INTENT WITH ARCHITECT PRIOR TO BIDDING. CLARIFICATIONS ISSUED AFTER BIDDING SHALL NOT BE BASIS FOR ADDITIONAL COMPENSATION. G EXISTING CONDITIONS MAY VARY FROM THOSE INDICATED. NOTIFY THE ARCHITECT IN WRITING OF DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS BEFORE PROCEEDING WITH THE WORK. H WHEN REMOVING A MATERIAL, COMPONENT, ASSEMBLY OR SYSTEM, “COMPLETE” SHALL MEAN THE MATERIAL, COMPONENT, ASSEMBLY OR SYSTEM, ALONG WITH ASSOCIATED SUSPENSION, HANGERS, BRACING, SHIMS, FASTENERS, ANCHORS, TRIM, ACCESSORIES, TRANSITION PIECES, ADHESIVES, SEALANTS, ETC., UNLESS OTHERWISE INDICATED. I CONTRACTORS ARE RESPONSIBLE FOR DECONSTRUCTION OF ASSEMBLIES OR SYSTEMS AS REQUIRED TO SEPARATE RECYCLABLE MATERIALS INTO THEIR CORRECT CATEGORIES. J SALVAGE MATERIALS AND EQUIPMENT AND TURN OVER TO THE OWNER AS INDICATED. SALVAGING SHALL INCLUDE THE REMOVAL OF INTACT ASSEMBLIES, THEIR STORAGE, PROTECTION, ORGANIZING AND RELOCATION UNLESS OTHERWISE INDICATED OR AS DIRECTED. K WHEN DURING THE COURSE OF THE WORK, EXISTING CONSTRUCTION INDICATED TO REMAIN IS DAMAGED, THE CONTRACTOR SHALL REPAIR OR REPLACE WITH IN-KIND MATERIAL TO LIKE-NEW CONDITION, AT NO EXPENSE TO THE OWNER. REPAIR OR REPLACEMENT METHODS AND MATERIALS SHALL BE SUBJECT TO THE ARCHITECT’S APPROVAL. L HAZARDOUS MATERIALS AND LEAD BASED PAINT TESTING AND REMEDIATION WILL BE DONE BY THE OWNER PRIOR TO START OF CONSTRUCTION. HOWEVER, WHEN IN THE COURSE OF THE WORK SUSPECT MATERIALS ARE ENCOUNTERED, THE CONTRACTOR SHALL STOP WORK IN THE AFFECTED AREA AND IMMEDIATELY NOTIFY THE OWNER'S PROJECT REPRESENTATIVE. M WHERE NEW OR ENLARGED OPENINGS ARE INDICATED IN EXISTING CONSTRUCTION CONTRACTORS SHALL COORDINATE SIZES AND LOCATIONS OF OPENINGS WITH THE FINISHED WORK. REFRAME OPENINGS IN STUD WALLS, INCLUDING NEW HEADER. N WHERE NEW OPENINGS ARE INDICATED IN UNIT MASONRY THAT WILL BE LEFT EXPOSED, PATCH MASONRY WITH IN-KIND UNITS WITH FINISHED SURFACES, TOOTHED IN, TO MATCH SURROUNDING COURSING AND BOND. PROVIDE LINTEL PER LINTEL SCHEDULE, UNLESS OTHERWISE INDICATED. O SHORE, BRACE AND SUPPORT STRUCTURAL ELEMENTS DURING CUTTING AND PATCHING. DO NOT CUT AND PATCH STRUCTURAL ELEMENTS IN A MANNER THAT COULD CHANGE THEIR LOAD CARRYING CAPACITY OR LOAD DEFLECTION RATIO. WHERE CUTTING AND PATCHING INVOLVE ADDING REINFORCEMENT TO STRUCTURAL ELEMENTS, SUBMIT DETAILS AND ENGINEERING CALCULATIONS OF A REGISTERED PROFESSIONAL (STRUCTURAL) ENGINEER, CURRENTLY LICENSED IN NEW YORK STATE, SHOWING INTEGRATION OF REINFORCEMENT WITH ORIGINAL STRUCTURE. P WHERE REMOVAL OF DOORS IS INDICATED, REMOVE HARDWARE, BOX, LABEL, AND TURN OVER TO THE OWNER UNLESS OTHERWISE INDICATED OR DIRECTED. GENERAL DRAWING NOTES A THE FOLLOWING GENERAL NOTES PERTAIN TO ALL DRAWINGS IN THIS PROJECT. B EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTS WHEN AVAILABLE. ALL EXISTING DIMENSIONS ARE APPROXIMATE AND SUBJECT TO CONTRACTOR'S VERIFICATION. EVERY ATTEMPT HAS BEEN MADE TO INDICATE PERTINENT EXISTING UTILITIES AND WALL CONDITIONS AS ACCURATELY AS POSSIBLE FROM EXISTING SURVEYS, DRAWINGS AND OTHER DATA. PRIOR TO THE BID OPENING, THE CONTRACTOR SHALL WALK THE JOB SITE AND SATISFY THEMSELVES TO EXISTING CONDITIONS. THE ARCHITECT SHALL BE CONSULTED WHEN ANY QUESTIONS ARISE RELATIVE TO MATERIALS OR CONDITIONS THAT ARE NOT SPECIFICALLY SHOWN OR SPECIFIED. C CONTRACTOR TO PROVIDE ALL INTERIOR LINTELS AT ALL MASONRY OPENINGS EXCEEDING 16" WIDE INCLUDING, BUT NOT LIMITED TO, DOORS, WINDOWS, LOUVERS, F.E.C., DUCTS, ETC. D PROVIDE CONCEALED 16 GAGE LIGHT METAL STEEL BACKING SUPPORT IN ALL STEEL STUD PARTITIONS BEHIND SURFACE FOR SEMI-RECESSED OR SURFACE MOUNTED ACCESSORIES. E CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL ACCESSORIES AND ITEMS REQUIRED FOR A COMPLETE AND PROPER INSTALLATION PER THE MANUFACTURER'S RECOMMENDATIONS. F SALVAGE MATERIAL AND EQUIPMENT FOR OWNER AS NOTED ON THE CONTRACT DOCUMENTS OR AS DIRECTED BY THE OWNER'S REPRESENTATIVE. G PROVIDE CONCEALED BLOCKING AND BACKING SUPPORT IN ALL STUD PARTITIONS BEHIND SURFACE FOR SEMI-RECESSED OR SURFACE MOUNTED ACCESSORIES H WHERE REQUIRED BY NFPA AND THE NEW YORK STATE BUILDING CODE, PROVIDE ALL NECESSARY UL RATED FIRE STOPPING AT ANY NEW AND EXISTING FLOOR/WALL PENETRATIONS THAT PASS THROUGH A RATED ASSEMBLY. VERIFY CONDITIONS IN FIELD AND LOCATIONS WITH OWNER I TOILET ROOM ACCESSORIES ARE GENERALLY SHOWN THROUGHOUT THE DOCUMENTS. COORDINATE EXACT LOCATIONS, SIZE AND TYPE WITH THE OWNER J WHERE REMOVALS OCCUR, ALL EXISTING VERTICAL OPENINGS CONNECTING TWO OR MORE FLOORS SHALL BE INFILLED WITH APPROVED ASSEMBLIES HAVING A FIRE-RESISTANCE RATING OF NOT LESS THAN 1 HOUR. WHEREVER POSSIBLE, MATCH EXISTING ADJACENT CONSTRUCTION. K WHERE NEW FASTENERS ARE REQUIRED FOR SECURELY ANCHORING NEW PARTITIONS, FIXTURES, MEP EQUIPMENT, ETC. TO EXISTING CONSTRUCTION, PROVIDE FASTENERS OF TYPE, MATERIAL, SIZE, SPACING, CORROSION RESISTANCE, HOLDING POWER, AND OTHER PROPERTIES WITH AN EVALUATION REPORT ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION AND AS RECOMMENDED BY MANUFACTURER FOR EXISTING CONDITIONS BEING ANCHORED INTO INCLUDING BUT NOT LIMITED TO, EXISTING SUBSTRATE AND FINISH MATERIALS, ENVIRONMENTAL / MOISTURE CONDITIONS, ETC. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING SOUNDNESS OF EXISTING MATERIALS TO BE ANCHORED INTO AND MAKING NECESSARY REPAIRS PRIOR TO ANCHORING NEW MATERIALS TO EXISTING CONSTRUCTION. BASIS OF DESIGN MANUFACTURER FOR FASTENERS IS FASTENAL OR EQUAL AS RECOMMENDED BY MANUFACTURER OF PRODUCT BEING ATTACHED. ENTRYALTERNATEENTRYADA ADA CLEARANCE PLUMBING FIXTURE AND TOILET ACCESSORY MOUNTING HEIGHT SCHEDULE FIXTURE OR ACCESSORY TYPE (ABBREVIATED) -NUMBERS SHOWN REPRESENT MOUNTING HEIGHT DESCRIPTION MARK WC (HCPD) WC UR (HCPD) UR LAV (HCPD) LAV TTD GB MR SD TOILET ROOM TYPE A (7-ADULT)TR-A 15 17 24 17 32 34 20 35 36" TO BOTTOM EDGE 48 1. COORDINATE WITH PLANS AND ELEVATIONS -MOUNTING HEIGHTS FOR SPECIFIC ACCESSORIES AND/ OR FIXTURES MAY BE SHOWN ELSEWHERE. USE THE HEIGHTS SHOWN ABOVE UNLESS NOTED OTHERWISE. (*) CHECK HEIGHT OF TANK/ FLUSH VALVE. SIDE GRAB BAR HEIGHTS WILL LIKELY NOT WORK AT BACK. IF SO, BACK BAR TO BE AT LOWEST HEIGHT TO PERMIT FREE HAND MOVEMENT ALONG BAR (1 1/2" CLEAR).MIRROR (OVER LAVATORY)MR(WXH)LAVATORY (LAV)URINAL (UR)WATER CLOSET (WC)MIRROR (FREESTANDING LARGE) MR(WXH)SOAP DISPENSER (SD)TOILET TISSUE DISPENSER (TTD)GRAB BAR (GB)SANITARY NAPKINDISPOSAL (SND)3'-2" MIN4'-0" MAXELECTRIC HANDDRYER (EHD)SHOWER UNITCOORDINATE HEAD HEIGHT WITH SCHEDULE CONTROL AREA CENTER MIRROR ON LAVS UNLESS NOTED OTHERWISE CENTER DISPENSER BETWEEN MIRRORS WHERE NECESSARY TTD IN ROOMS TYPE A SHALL MOUNT WITH LEADING EDGE OF THE DISPENSER PARALLEL TO THE FRONT OF THE BOWL. TOILET TISSUE DISPENSER REPRESENTS THE BOTTOM OF THE TOILET PARTITION 8" SANITARY NAPKIN RECEPTACLE (WHERE SHOWN) 1'-4"6" 6"3'-0"1'-0"4'-0"TOP OF SEATRIMTO REFLECTIVE SURFACE.TO CENTERLINE..1'-6"3'-4" FIXED SIDE WALL VERTICAL GRAB BAR 3'-4"(SH)FIXED SHOWER HEADSH 59" MIN HOSE LENGTHRIM..1'-5".4'-9"1'-0"1'-0" VERTICAL GRAB BAR CLEAR FLOOR SPACE AT FIXTURE TURNING RADIUS 8" TYP ENTRY LOCATIONS COORD W/ PLANS 8" SND SND 30** (**) MOUNT TOP OF SANITARY NAPKIN DISPENSER (SND) 4" BELOW BOTTOM OF GRAB BAR OR AS REQUIRED TO OPERATE LID. FIXTURE ACCESSORY MOUNTING HEIGHTS COMPLY WITH ANSI 117.1 80 F F17'-2"3'-4"2"2"2" SECTION 08 71 00 –DOOR HARDWARE PART 1 -GENERAL 1.1 SUBMITTALS A. PRODUCT DATA: MANUFACTURER'S PRODUCT DATA SHEETS INCLUDING INSTALLATION DETAILS, MATERIAL DESCRIPTIONS, DIMENSIONS OF INDIVIDUAL COMPONENTS AND PROFILES, OPERATIONAL DESCRIPTIONS AND FINISHES. B. DOOR HARDWARE SCHEDULE: PREPARED BY OR UNDER THE SUPERVISION OF SUPPLIER, DETAILING FABRICATION AND ASSEMBLY OF DOOR HARDWARE, AS WELL AS PROCEDURES AND DIAGRAMS. COORDINATE THE FINAL DOOR HARDWARE SCHEDULE WITH DOORS, FRAMES, AND RELATED WORK TO ENSURE PROPER SIZE, THICKNESS, HAND, FUNCTION, AND FINISH OF DOOR HARDWARE. 1. FORMAT: COMPLY WITH SCHEDULING SEQUENCE AND VERTICAL FORMAT IN DHI'S "SEQUENCE AND FORMAT FOR THE HARDWARE SCHEDULE." 2. ORGANIZATION: ORGANIZE THE DOOR HARDWARE SCHEDULE INTO DOOR HARDWARE SETS INDICATING COMPLETE DESIGNATIONS OF EVERY ITEM REQUIRED FOR EACH DOOR OR OPENING. ORGANIZE DOOR HARDWARE SETS IN SAME ORDER AS IN THE DOOR HARDWARE SETS AT THE END OF PART 3. SUBMITTALS THAT DO NOT FOLLOW THE SAME FORMAT AND ORDER AS THE DOOR HARDWARE SETS WILL BE REJECTED AND SUBJECT TO RESUBMISSION. 3. SUBMITTAL SEQUENCE: SUBMIT THE FINAL DOOR HARDWARE SCHEDULE AT EARLIEST POSSIBLE DATE, PARTICULARLY WHERE APPROVAL OF THE DOOR HARDWARE SCHEDULE MUST PRECEDE FABRICATION OF OTHER WORK THAT IS CRITICAL IN THE PROJECT CONSTRUCTION SCHEDULE. INCLUDE PRODUCT DATA, SAMPLES, SHOP DRAWINGS OF OTHER WORK AFFECTED BY DOOR HARDWARE, AND OTHER INFORMATION ESSENTIAL TO THE COORDINATED REVIEW OF THE DOOR HARDWARE SCHEDULE. 4. CONTENT: INCLUDE THE FOLLOWING INFORMATION: a. TYPE, STYLE, FUNCTION, SIZE, LABEL, HAND, AND FINISH OF EACH DOOR HARDWARE ITEM. b. MANUFACTURER OF EACH ITEM. c. FASTENINGS AND OTHER PERTINENT INFORMATION. d. LOCATION OF DOOR HARDWARE SET, CROSS-REFERENCED TO DRAWINGS, BOTH ON FLOOR PLANS AND IN DOOR AND FRAME SCHEDULE. e. EXPLANATION OF ABBREVIATIONS, SYMBOLS, AND CODES CONTAINED IN SCHEDULE. f. MOUNTING LOCATIONS FOR DOOR HARDWARE. g. DOOR AND FRAME SIZES AND MATERIALS. h. WARRANTY INFORMATION FOR EACH PRODUCT. 1.2 WARRANTY A. GENERAL WARRANTY: REFERENCE DIVISION 01, GENERAL REQUIREMENTS. SPECIAL WARRANTIES SPECIFIED IN THIS ARTICLE SHALL NOT DEPRIVE OWNER OF OTHER RIGHTS OWNER MAY HAVE UNDER OTHER PROVISIONS OF THE CONTRACT DOCUMENTS AND SHALL BE IN ADDITION TO, AND RUN CONCURRENT WITH, OTHER WARRANTIES MADE BY CONTRACTOR UNDER REQUIREMENTS OF THE CONTRACT DOCUMENTS. B. WARRANTY PERIOD: WRITTEN WARRANTY, EXECUTED BY MANUFACTURER(S), AGREEING TO REPAIR OR REPLACE COMPONENTS OF STANDARD AND ELECTRIFIED DOOR HARDWARE THAT FAILS IN MATERIALS OR WORKMANSHIP WITHIN SPECIFIED WARRANTY PERIOD AFTER FINAL ACCEPTANCE BY THE OWNER. FAILURES INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: 1. STRUCTURAL FAILURES INCLUDING EXCESSIVE DEFLECTION, CRACKING, OR BREAKAGE. 2. FAULTY OPERATION OF THE HARDWARE. 3. DETERIORATION OF METALS, METAL FINISHES, AND OTHER MATERIALS BEYOND NORMAL WEATHERING. C. STANDARD WARRANTY PERIOD: ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION, UNLESS OTHERWISE INDICATED. D. SPECIAL WARRANTY PERIODS: 1. TEN YEARS FOR MORTISE LOCKS AND LATCHES. 2. FIVE YEARS FOR EXIT HARDWARE. 3. TEN YEARS FOR MANUAL SURFACE DOOR CLOSERS. 1.3 MAINTENANCE SERVICE A. MAINTENANCE TOOLS AND INSTRUCTIONS: FURNISH A COMPLETE SET OF SPECIALIZED TOOLS AND MAINTENANCE INSTRUCTIONS AS NEEDED FOR OWNER'S CONTINUED ADJUSTMENT, MAINTENANCE, AND REMOVAL AND REPLACEMENT OF DOOR HARDWARE. B. CONTINUING SERVICE: BEGINNING AT SUBSTANTIAL COMPLETION, AND RUNNING CONCURRENT WITH THE SPECIFIED WARRANTY PERIOD, PROVIDE CONTINUOUS (6) MONTHS FULL MAINTENANCE INCLUDING REPAIR AND REPLACEMENT OF WORN OR DEFECTIVE COMPONENTS, LUBRICATION, CLEANING, AND ADJUSTING AS REQUIRED FOR PROPER DOOR OPENING OPERATION. PROVIDE PARTS AND SUPPLIES AS USED IN THE MANUFACTURE AND INSTALLATION OF ORIGINAL PRODUCTS. PART 2 -PRODUCTS 2.1 HANGING DEVICES A. HINGES: ANSI/BHMA A156.1 CERTIFIED BUTT HINGES 1. QUANTITY: PROVIDE THE FOLLOWING HINGE QUANTITY, UNLESS OTHERWISE INDICATED: a. THREE HINGES: FOR DOORS WITH HEIGHTS 61 TO 90 INCHES. 2. HINGE SIZE: PROVIDE THE FOLLOWING, UNLESS OTHERWISE INDICATED, WITH HINGE WIDTHS SIZED FOR DOOR THICKNESS AND CLEARANCES REQUIRED. a. WIDTHS UP TO 3’0”: 4-1/2”STANDARD. 3. ACCEPTABLE MANUFACTURERS: a. BOMMER INDUSTRIES (BO). b. HAGER COMPANIES (HA). c. MCKINNEY PRODUCTS (MK). PREFERRED BRAND. 2.2 CYLINDERS AND KEYING A. GENERAL: CYLINDER MANUFACTURER TO HAVE MINIMUM (10) YEARS’EXPERIENCE DESIGNING SECURED MASTER KEY SYSTEMS AND HAVE ON RECORD A PUBLISHED SECURITY KEYING SYSTEM POLICY. B. SOURCE LIMITATIONS: OBTAIN EACH TYPE OF KEYED CYLINDER AND KEYS FROM THE SAME SOURCE MANUFACTURER AS LOCKSETS AND EXIT DEVICES, UNLESS OTHERWISE INDICATED. 1. ACCEPTABLE MANUFACTURERS: a. SARGENT MANUFACTURING (SA). C. CYLINDERS: ORIGINAL MANUFACTURER CYLINDERS COMPLYING WITH THE FOLLOWING: 1. MATCH EXISTING CYLINDERS PROVIDED THROUGHOUT BUILDING WHERE REQUIRED BY OWNER. 2. KEYWAY: MATCH FACILITY RESTRICTED KEYWAY. D. KEYING SYSTEM: EACH TYPE OF LOCK AND CYLINDERS TO BE FACTORY KEYED. FURNISH FACTORY CUT, NICKEL-SILVER LARGE BOW PERMANENTLY INSCRIBED WITH A VISUAL KEY CONTROL NUMBER AS DIRECTED BY OWNER. INCORPORATE DECISIONS AS FOLLOWS: 1. EXISTING SYSTEM: MASTER KEY OR GRAND MASTER KEY LOCKS TO OWNER'S EXISTING SYSTEM. E. KEY QUANTITY: COORDINATE THE MINIMUM NUMBER OF KEYS REQUIRED WITH OWNER. F.CONSTRUCTION KEYING: PROVIDE CONSTRUCTION MASTER KEYS IN QUANTITY AS REQUIRED BY PROJECT CONTRACTOR. REPLACE CONSTRUCTION CORES WITH PERMANENT CORES. FURNISH PERMANENT CORES FOR INSTALLATION AS DIRECTED BY OWNER. G.KEY REGISTRATION LIST: PROVIDE KEYING TRANSCRIPT LIST TO OWNER'S REPRESENTATIVE IN THE PROPER FORMAT FOR IMPORTING INTO KEY CONTROL SOFTWARE. 2.3 MECHANICAL LOCKS AND LATCHING DEVICES A. MORTISE LOCKSETS, GRADE 1 (HEAVY DUTY): ANSI/BHMA A156.13, SERIES 1000, OPERATIONAL GRADE 1 CERTIFIED MORTISE LOCKSETS FURNISHED IN THE FUNCTIONS AS SPECIFIED IN THE HARDWARE SETS. LOCKSETS TO BE MANUFACTURED WITH A CORROSION RESISTANT, STAMPED 12 GAUGE MINIMUM FORMED STEEL CASE AND BE FIELD- REVERSIBLE FOR HANDING WITHOUT DISASSEMBLY OF THE LOCK BODY. LOCKSET TRIM (INCLUDING KNOBS, LEVERS, ESCUTCHEONS, ROSES) TO BE THE PRODUCT OF A SINGLE MANUFACTURER. FURNISH WITH STANDARD 2 3/4" BACKSET, 3/4" THROW ANTI-FRICTION STAINLESS STEEL LATCHBOLT, AND A FULL 1" THROW STAINLESS STEEL BOLT FOR DEADBOLT FUNCTIONS. 1. ACCEPTABLE MANUFACTURERS: a. SARGENT MANUFACTURING (SA) –8200 SERIES. B. LOCK TRIM DESIGN: SARGENT LNL. 2.4 LOCK AND LATCH STRIKES A. STRIKES: PROVIDE MANUFACTURER'S STANDARD STRIKE WITH STRIKE BOX FOR EACH LATCH OR LOCK BOLT, WITH CURVED LIP EXTENDED TO PROTECT FRAME, FINISHED TO MATCH DOOR HARDWARE SET, UNLESS OTHERWISE INDICATED, AND AS FOLLOWS: 1. FLAT-LIP STRIKES: FOR LOCKS WITH THREE-PIECE ANTIFRICTION LATCHBOLTS, AS RECOMMENDED BY MANUFACTURER. B. STANDARDS: COMPLY WITH THE FOLLOWING: 1. STRIKES FOR MORTISE LOCKS AND LATCHES: BHMA A156.13. 2.5 DOOR CLOSERS A. ALL DOOR CLOSERS SPECIFIED HEREIN SHALL MEET OR EXCEED THE FOLLOWING CRITERIA: 1. GENERAL: DOOR CLOSERS TO BE FROM ONE MANUFACTURER, MATCHING IN DESIGN AND STYLE, WITH THE SAME TYPE DOOR PREPARATIONS AND TEMPLATES REGARDLESS OF APPLICATION OR SPRING SIZE. CLOSERS TO BE NON-HANDED WITH FULL SIZED COVERS INCLUDING INSTALLATION AND ADJUSTING INFORMATION ON INSIDE OF COVER. 2. STANDARDS: CLOSERS TO COMPLY WITH UL-10C AND UBC 7-2 FOR POSITIVE PRESSURE FIRE TEST AND BE U.L. LISTED FOR USE OF FIRE RATED DOORS. 3. CYCLE TESTING: PROVIDE CLOSERS WHICH HAVE SURPASSED 15 MILLION CYCLES IN A TEST WITNESSED AND VERIFIED BY UL. 4. SIZE OF UNITS: COMPLY WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR SIZING OF DOOR CLOSERS DEPENDING ON SIZE OF DOOR, EXPOSURE TO WEATHER, AND ANTICIPATED FREQUENCY OF USE. WHERE CLOSERS ARE INDICATED FOR DOORS REQUIRED TO BE ACCESSIBLE TO THE PHYSICALLY HANDICAPPED, PROVIDE UNITS COMPLYING WITH ANSI ICC/A117.1. 5. CLOSER ACCESSORIES: PROVIDE DOOR CLOSER ACCESSORIES INCLUDING CUSTOM TEMPLATES, SPECIAL MOUNTING BRACKETS, SPACERS AND DROP PLATES, AND THROUGH-BOLT OR SECURITY TYPE FASTENERS AS REQUIRED. B. DOOR CLOSERS, SURFACE MOUNTED (HEAVY DUTY): ANSI/BHMA A156.4, GRADE 1 SURFACE MOUNTED, HEAVY DUTY DOOR CLOSERS WITH COMPLETE SPRING POWER ADJUSTMENT, SIZES 1 THRU 6; AND FULLY OPERATIONAL ADJUSTABLE ACCORDING TO DOOR SIZE, FREQUENCY OF USE, AND OPENING FORCE. CLOSERS TO BE RACK AND PINION TYPE, ONE PIECE CAST IRON OR ALUMINUM ALLOY BODY CONSTRUCTION, WITH ADJUSTABLE BACKCHECK AND SEPARATE NON-CRITICAL VALVES FOR CLOSING SWEEP AND LATCH SPEED CONTROL. PROVIDE NON-HANDED UNITS STANDARD. 1. ACCEPTABLE MANUFACTURERS: a. LCN CLOSERS (LC) -4040XP SERIES. b. SARGENT MANUFACTURING (SA) -351 SERIES. PREFERRED BRAND 2.6 ARCHITECTURAL TRIM A. DOOR PROTECTIVE TRIM 1. GENERAL: DOOR PROTECTIVE TRIM UNITS TO BE OF TYPE AND DESIGN AS SPECIFIED BELOW OR IN THE HARDWARE SETS. 2. SIZE: FABRICATE PROTECTION PLATES (KICK, ARMOR, OR MOP) NOT MORE THAN 2" LESS THAN DOOR WIDTH (LDW) ON STOP SIDE OF SINGLE DOORS AND 1”LDW ON STOP SIDE OF PAIRS OF DOORS, AND NOT MORE THAN 1" LESS THAN DOOR WIDTH ON PULL SIDE. COORDINATE AND PROVIDE PROPER WIDTH AND HEIGHT AS REQUIRED WHERE CONFLICTING HARDWARE DICTATES. HEIGHT TO BE 6”. 3. METAL PROTECTION PLATES: ANSI/BHMA A156.6 CERTIFIED METAL PROTECTION PLATES (KICK, ARMOR, OR MOP), BEVELED ON FOUR EDGES (B4E), FABRICATED FROM THE FOLLOWING: a. STAINLESS STEEL: 300 SERIES, 050-INCH THICK FASTENERS: PROVIDE MANUFACTURER'S DESIGNATED FASTENER TYPE AS SPECIFIED IN THE HARDWARE SETS. 4. ACCEPTABLE MANUFACTURERS: a. BURNS MANUFACTURING (BU). b. ROCKWOOD MANUFACTURING (RO). c. TRIMCO (TC). 2.7 DOOR STOPS A. GENERAL: DOOR STOPS TO BE OF TYPE AND DESIGN AS SPECIFIED BELOW OR IN THE HARDWARE SETS. B. DOOR STOPS AND BUMPERS: ANSI/BHMA A156.16, GRADE 1 CERTIFIED DOOR STOPS AND WALL BUMPERS. PROVIDE WALL BUMPERS, EITHER CONVEX OR CONCAVE TYPES WITH ANCHORAGE AS INDICATED, UNLESS FLOOR OR OTHER TYPES OF DOOR STOPS ARE SPECIFIED IN HARDWARE SETS. DO NOT MOUNT FLOOR STOPS WHERE THEY WILL IMPEDE TRAFFIC. WHERE FLOOR OR WALL BUMPERS ARE NOT APPROPRIATE, PROVIDE OVERHEAD TYPE STOPS AND HOLDERS. 1. ACCEPTABLE MANUFACTURERS: a. BURNS MANUFACTURING (BU). b. ROCKWOOD MANUFACTURING (RO). c. TRIMCO (TC). 2.8 ARCHITECTURAL SEALS A. GENERAL: THRESHOLDS, WEATHERSTRIPPING, AND GASKET SEALS TO BE OF TYPE AND DESIGN AS SPECIFIED BELOW OR IN THE HARDWARE SETS. PROVIDE SMOKE, GASKETING ON INTERIOR DOORS WHERE INDICATED. B. SMOKE LABELED GASKETING: ASSEMBLIES COMPLYING WITH NFPA 105 THAT ARE LISTED AND LABELED BY A TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, FOR SMOKE CONTROL RATINGS INDICATED, BASED ON TESTING ACCORDING TO UL 1784. 1. PROVIDE SMOKE LABELED PERIMETER GASKETING AT ALL SMOKE LABELED OPENINGS. C. FIRE LABELED GASKETING: ASSEMBLIES COMPLYING WITH NFPA 80 THAT ARE LISTED AND LABELED BY A TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, FOR FIRE RATINGS INDICATED, BASED ON TESTING ACCORDING TO UL-10C. D. REPLACEABLE SEAL STRIPS: PROVIDE ONLY THOSE UNITS WHERE RESILIENT OR FLEXIBLE SEAL STRIPS ARE EASILY REPLACEABLE AND READILY AVAILABLE FROM STOCKS MAINTAINED BY MANUFACTURER. E. ACCEPTABLE MANUFACTURERS: 1. NATIONAL GUARD PRODUCTS (NG). 2. PEMKO MANUFACTURING (PE). 3. REESE ENTERPRISES, INC. (RS). 2.9 FABRICATION A. FASTENERS: PROVIDE DOOR HARDWARE MANUFACTURED TO COMPLY WITH PUBLISHED TEMPLATES GENERALLY PREPARED FOR MACHINE, WOOD, AND SHEET METAL SCREWS. PROVIDE SCREWS ACCORDING TO MANUFACTURERS RECOGNIZED INSTALLATION STANDARDS FOR APPLICATION INTENDED. 2.10 FINISHES A. STANDARD: DESIGNATIONS USED IN THE HARDWARE SETS AND ELSEWHERE INDICATE HARDWARE FINISHES COMPLYING WITH ANSI/BHMA A156.18, INCLUDING COORDINATION WITH TRADITIONAL U.S. FINISHES INDICATED BY CERTAIN MANUFACTURERS FOR THEIR PRODUCTS. B. PROVIDE QUALITY OF FINISH, INCLUDING THICKNESS OF PLATING OR COATING (IF ANY), COMPOSITION, HARDNESS, AND OTHER QUALITIES COMPLYING WITH MANUFACTURER'S STANDARDS, BUT IN NO CASE LESS THAN SPECIFIED BY REFERENCED STANDARDS FOR THE APPLICABLE UNITS OF HARDWARE. C. PROTECT MECHANICAL FINISHES ON EXPOSED SURFACES FROM DAMAGE BY APPLYING A STRIPPABLE, TEMPORARY PROTECTIVE COVERING BEFORE SHIPPING. PART 3 -EXECUTION 3.1 3.01 EXAMINATION A.EXAMINE SCHEDULED OPENINGS, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH REQUIREMENTS FOR INSTALLATION TOLERANCES, LABELED FIRE DOOR ASSEMBLY CONSTRUCTION, WALL AND FLOOR CONSTRUCTION, AND OTHER CONDITIONS AFFECTING PERFORMANCE. B.NOTIFY ARCHITECT OF ANY DISCREPANCIES OR CONFLICTS BETWEEN THE DOOR SCHEDULE, DOOR TYPES, DRAWINGS AND SCHEDULED HARDWARE. PROCEED ONLY AFTER SUCH DISCREPANCIES OR CONFLICTS HAVE BEEN RESOLVED IN WRITING. 3.02 PREPARATION A.HOLLOW METAL DOORS AND FRAMES: COMPLY WITH ANSI/DHI A115 SERIES. B.WOOD DOORS: COMPLY WITH ANSI/DHI A115-W SERIES. 3.03 INSTALLATION A.INSTALL EACH ITEM OF MECHANICAL HARDWARE TO COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND ACCORDING TO SPECIFICATIONS. 1.INSTALLERS ARE TO BE TRAINED AND CERTIFIED BY THE MANUFACTURER ON THE PROPER INSTALLATION AND ADJUSTMENT OF FIRE, LIFE SAFETY, AND SECURITY PRODUCTS INCLUDING: HANGING DEVICES, LOCKING DEVICES, CLOSING DEVICES, AND SEALS. B.MOUNTING HEIGHTS: MOUNT DOOR HARDWARE UNITS AT HEIGHTS INDICATED IN FOLLOWING APPLICABLE PUBLICATIONS, UNLESS SPECIFICALLY INDICATED OR REQUIRED TO COMPLY WITH GOVERNING REGULATIONS: 1.STANDARD STEEL DOORS AND FRAMES: DHI'S "RECOMMENDED LOCATIONS FOR ARCHITECTURAL HARDWARE FOR STANDARD STEEL DOORS AND FRAMES." 2.WOOD DOORS: DHI WDHS.3, "RECOMMENDED LOCATIONS FOR ARCHITECTURAL HARDWARE FOR WOOD FLUSH DOORS." 3.WHERE INDICATED TO COMPLY WITH ACCESSIBILITY REQUIREMENTS, COMPLY WITH ANSI A117.1 "ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES." 4.PROVIDE BLOCKING IN DRYWALL PARTITIONS WHERE WALL STOPS OR OTHER WALL MOUNTED HARDWARE IS LOCATED. C.RETROFITTING: INSTALL DOOR HARDWARE TO COMPLY WITH MANUFACTURER'S PUBLISHED TEMPLATES AND WRITTEN INSTRUCTIONS. WHERE CUTTING AND FITTING ARE REQUIRED TO INSTALL DOOR HARDWARE ONTO OR INTO SURFACES THAT ARE LATER TO BE PAINTED OR FINISHED IN ANOTHER WAY, COORDINATE REMOVAL, STORAGE, AND REINSTALLATION OF SURFACE PROTECTIVE TRIM UNITS WITH FINISHING WORK. DO NOT INSTALL SURFACE-MOUNTED ITEMS UNTIL FINISHES HAVE BEEN COMPLETED ON SUBSTRATES INVOLVED. D.THRESHOLDS: SET THRESHOLDS FOR EXTERIOR AND ACOUSTICAL DOORS IN FULL BED OF SEALANT. E.STORAGE: PROVIDE A SECURE LOCK UP FOR HARDWARE DELIVERED TO THE PROJECT BUT NOT YET INSTALLED. CONTROL THE HANDLING AND INSTALLATION OF HARDWARE ITEMS SO THAT THE COMPLETION OF THE WORK WILL NOT BE DELAYED BY HARDWARE LOSSES BEFORE AND AFTER INSTALLATION. 3.04 FIELD QUALITY CONTROL A.FIELD INSPECTION: SUPPLIER WILL PERFORM A FINAL INSPECTION OF INSTALLED DOOR HARDWARE AND STATE IN REPORT WHETHER WORK COMPLIES WITH OR DEVIATES FROM REQUIREMENTS, INCLUDING WHETHER DOOR HARDWARE IS PROPERLY INSTALLED, OPERATING AND ADJUSTED. 3.05 ADJUSTING A.INITIAL ADJUSTMENT: ADJUST AND CHECK EACH OPERATING ITEM OF DOOR HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OR FUNCTION OF EVERY UNIT. REPLACE UNITS THAT CANNOT BE ADJUSTED TO OPERATE AS INTENDED. ADJUST DOOR CONTROL DEVICES TO COMPENSATE FOR FINAL OPERATION OF HEATING AND VENTILATING EQUIPMENT AND TO COMPLY WITH REFERENCED ACCESSIBILITY REQUIREMENTS. 3.06 CLEANING AND PROTECTION A.PROTECT ALL HARDWARE STORED ON CONSTRUCTION SITE IN A COVERED AND DRY PLACE. PROTECT EXPOSED HARDWARE INSTALLED ON DOORS DURING THE CONSTRUCTION PHASE. INSTALL ANY AND ALL HARDWARE AT THE LATEST POSSIBLE TIME FRAME. B.CLEAN ADJACENT SURFACES SOILED BY DOOR HARDWARE INSTALLATION. C.CLEAN OPERATING ITEMS AS NECESSARY TO RESTORE PROPER FINISH. PROVIDE FINAL PROTECTION AND MAINTAIN CONDITIONS THAT ENSURE DOOR HARDWARE IS WITHOUT DAMAGE OR DETERIORATION AT TIME OF OWNER OCCUPANCY. 3.07 DEMONSTRATION A.INSTRUCT OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN MECHANICAL AND DOOR HARDWARE. 3.08 DOOR HARDWARE SCHEDULE A.THE HARDWARE SETS REPRESENT THE DESIGN INTENT AND DIRECTION OF THE OWNER AND ARCHITECT. THEY ARE A GUIDELINE ONLY AND SHOULD NOT BE CONSIDERED A DETAILED HARDWARE SCHEDULE. DISCREPANCIES, CONFLICTING HARDWARE AND MISSING ITEMS SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT WITH CORRECTIONS MADE PRIOR TO THE BIDDING PROCESS. OMITTED ITEMS NOT INCLUDED IN A HARDWARE SET SHOULD BE SCHEDULED WITH THE APPROPRIATE ADDITIONAL HARDWARE REQUIRED FOR PROPER APPLICATION AND FUNCTIONALITY. Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. ©Filename:Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE no. revision description by date 4/13/2020 11:13:07 AMC:\Projects\BEAR-A-19100-V2018_nhavrish.rvtALL TRADES Cornell UniversityG-002 04.15.2020 DOOR SCHEDULE, SPECIFICATIONS, TOILET ROOM ACCESSORIES & DETAILS Zeta Psi Bathroom Renovations534 Thurston Avenue Ithaca, NY 14850NRH 19100 MAR NRH 2020 TOILET ACCESSORY SCHEDULE MARK DESCRIPTION MANUFACTURER PRODUCT # FINISH HARDWARE COMMENTS ELECTRIC HAND DRYER EHD SEMI RECESSED ELECTRIC HAND DRYER PROVIDE ALL HARDWARE AND CONNECTIONS REQD TO INSTALL NEW HAND DRYERS GRAB BARS VGB18 18" HIGH VERTICAL GRAB BAR BRADLEY CORPORATION 812 SERIES STAINLESS STEEL CONCEALED MOUNTING HARDWARE PROVIDE BLOCKING INSIDE WALL CAVITY (WHERE APPLICABLE) TO SECURE GRAB BARS. GRAB BARS SHALL NOT BE SECURE WITH HOLLOW WALL ANCHORS GB48 48" LONG HORIZONTAL GRAB BAR BRADLEY CORPORATION 812 SERIES STAINLESS STEEL CONCEALED MOUNTING HARDWARE PROVIDE BLOCKING INSIDE WALL CAVITY (WHERE APPLICABLE) TO SECURE GRAB BARS. GRAB BARS SHALL NOT BE SECURE WITH HOLLOW WALL ANCHORS GB36 36" LONG HORIZONTAL GRAB BAR BRADLEY CORPORATION 812 SERIES STAINLESS STEEL CONCEALED MOUNTING HARDWARE PROVIDE BLOCKING INSIDE WALL CAVITY (WHERE APPLICABLE) TO SECURE GRAB BARS. GRAB BARS SHALL NOT BE SECURE WITH HOLLOW WALL ANCHORS MIRRORS MR TEMPERED GLASS MIRROR WITH STAINLESS STEEL CHANNEL FRAME - SIZE AS INDICATED ON DRAWINGS BRADLEY CORPORATION 781 SERIES N/A PARTITIONS USCRN 17" DEEP BY 48" HIGH HDPE URINAL SCREEN BRADLEY CORPORATION CHARCOAL GRAY M248 CONTINUOUS STAINLESS STEEL MOUNTING BRACKET PROVIDE BLOCKING INSIDE WALL CAVITY (WHERE APPLICABLE) TO SECURE URINAL SCREEN. URINAL SCREEN SHALL NOT BE SECURE WITH HOLLOW WALL ANCHORS TPTN SOLID HDPE, NO-SITE, OVERHEAD BRACED TOILET PARTITION BRADLEY CORPORATION SERIES 400 CHARCOAL GRAY M248 CONTINUOUS STAINLESS STEEL MOUNTING BRACKET; STAINLESS STEEL SURFACE-MOUNTED LATCH AND KEEPER; STAINLESS STEEL SURFACE-MOUNTED HINGE. ANODIZED ALUMINUM HEADRAIL WITH ANTI-GRIP PROFILE. ALL ADA STALL DOORS SHALL HAVE CONTINUOUS, SPRING-LOADED, STAINLESS STEEL HINGES AND BE SELF CLOSING PROVIDE BLOCKING INSIDE WALL CAVITY (WHERE APPLICABLE) TO SECURE PARTITION. TOILET PARTITION SHALL NOT BE SECURE WITH HOLLOW WALL ANCHORS. PROVIDE 1-PIECE, 4" HIGH, 300 SERIES SHOES AT ALL PILASTERS. EXCEPT WHERE OTHERWISE NOTED AND REQUIRED BY ADA GUIDELINES, ALL STALL DOORS SHALL BE 24". SANITARY NAPKIN DISPOSAL SND SMOOTH, SURFACE MOUNTED PLASTIC WITH SELF CLOSING PANEL IMPACT PRODUCTS 25125200 WHITE TOILET TISSUE DISPENSER TTD DUAL ROLL DISPENSER FOR TOILET TISSUE GP COMPACT CORELESS AS SELECTED BY OWNER AS SELECTED SCALE:1/4" = 1'-0" FIXTURE MOUNTING HEIGHT SCHEDULE SCALE:1/4" = 1'-0" DOOR FRAME & TYPE DOOR GENERAL NOTES A THESE NOTES APPLY TO ALL OPENINGS AFFECTED BY "THE WORK" UNLESS NOTED OTHERWISE. B PROVIDE ALL DOOR, FRAME AND HARDWARE MOUNTING ACCESSORIES REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, INCLUDING BUT NOT LIMITED TO, FRAME CLIPS, SPACERS, FILLER, FASTENERS, ETC... C ALL NEW OR EXISTING DOORS AND FRAMES EFFECTED BY "THE WORK" SHALL RECIEVE SURFACE PREPARATION AND PAINTING ULESS OTHERWISE INDICATED. SURFACE PREPARATION SHALL INCLUDE, BUT NOT BE LIMITED TO, INFILL OF EXISTING HOLES, INSTALLATION OF BLANKS, GENERAL CLEANING AND SPOT PRIMING OF SURFACES AS NECESSARY FOR APPLICATION OF SPECIFIED FINISH. IF A NEW DOOR IS INSTALLED IN A NEW OR EXISTING FRAME, THAT FRAME SHALL BE PREPARED AND FINISHED AS DESCRIBED ABOVE; ALL SURFACES SHALL BE INCLUDED. D ALL NEW HARDWARE FINISHES SHALL MATCH EXISTING COLOR AND FINISH. SUBMIT FINISHES FOR FINAL APPROVAL BY OWNER AND ARCHITECT. DOOR HARDWARE GROUPS QTY ITEM MFR MODEL REMARKS GROUP 1 3 HINGE MCKINNEY AS REQD 1 DORMITORY LOCKSET (WITH PRIVACY INDICATOR) SARGENT 50 8225 LNL LATCH TO READ "OCCUPIED" IN LOCKED POSITION 1 DOOR CLOSER SARGENT 351 UO 1 KICK PLATE ROCKWOOD K1050 6" HIGH 1 WALL STOP ROCKWOOD 406 1 GASKETING PEMKO S773BL PLUMBING SPECIFICATIONS ACTION SUBMITTALS A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED IN SPECIFICATIONS AND ON DRAWINGS. CUTTING AND PATCHING A. PROVIDE ALL CUTTING AND PATCHING (UNLESS OTHERWISE NOTED ON PLANS) REQUIRED TO PERFORM PLUMBING WORK. B. EXISTING CONDITIONS 1. SIZE AND LOCATIONS OF ALL EXISTING CONCEALED PIPING IS BASED ON INFORMATION OBTAINED FROM PREVIOUS PLANS AND DRAWINGS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERITY ALL EXISTING SIZES AND LOCATIONS IN THE FIELD. CORE DRILLING A. CORE DRILLING REQUIRED FOR PLUMBING WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. B. THE PLUMBING TRADE IS RESPONSIBLE FOR OBTAINING APPROVAL FROM THE BUILDING OWNER FOR ALL CORE DRILLING LOCATIONS. C. REHABILITATION PROJECTS AND EXISTING BUILDINGS 1. SLEEVES ARE NOT REQUIRED FOR PIPING PASSING THROUGH EXISTING FLOORS, INSIDE WALLS, AND PARTITIONS, WHICH HAVE BEEN NEATLY CORE DRILLED. REMOVALS A. REMOVE ALL EXISTING MATERIALS AND EQUIPMENT USUALLY INCLUDED IN THE WORK OF THIS DIVISION (WHETHER SPECIFICALLY INCLUDED HEREIN OR NOT) FROM CONSTRUCTION WHICH IS SCHEDULED TO BE DEMOLISHED. THE PLUMBING TRADE SHALL PATCH EXISTING CONSTRUCTION AND FINISHES DAMAGED OR LEFT INCOMPLETE DUE TO REMOVALS. B. REFER TO ARCHITECTURAL PLANS AND SCHEDULES TO DETERMINE EXTENT OF CONSTRUCTION BEING REMOVED, AND VISIT JOB SITE TO EXAMINE EXISTING CONDITIONS. PLUMBING SYSTEMS IDENTIFICATION DESCRIPTION A. VALVE SERVICE IDENTIFICATION TAGS 1. NO. 19 B & S GAUGE BRASS, OR APPROVED EQUAL, WITH 1/4" HIGH VALVE SERVICE ABBREVIATED LETTERING ON ONE LINE OVER 1/2" HIGH VALVE SERVICE CHART NUMBER, WITH 3/16" TOP HOLE FOR FASTENER. TAGS, DEEP STAMPED AND BLACK FILLED; 1 1/2" ROUND FOR PLUMBING USE. LABELS A. PROVIDE "ASBESTOS FREE" LABELS APPLIED TO THE EXTERIOR JACKET OF ALL NON-ASBESTOS PIPE INSULATION INSTALLED UNDER THIS CONTRACT. APPLY SUCH MARKINGS AT 20 FOOT INTERVALS. B. PROVIDE IDENTIFICATION LABELS AND FLOW ARROWS ON ALL DOMESTIC WATER PIPING, RAIN WATER SUPPLY, HOT, COLD, RECIRC, SANITARY, STORM WATER AND VENT PIPING. APPLY SUCH MARKINGS AT 20 FOOT INTERVALS. INSTALLATION A. APPLICATION 1. TAG EVERY VALVE, COCK AND CONTROL DEVICE IN EACH PIPING SYSTEM; EXCLUDE CHECK VALVES, VALVES WITHIN EQUIPMENT UNITS, HOSE BIBBS, FAUCETS AND SHUT-OFF VALVE OF PLUMBING FIXTURES, AND SIMILAR MULTIPLE UNIT TERMINAL VALVES. VALVE SCHEDULE A. PREPARE AND SUBMIT VALVE TAG SCHEDULE (IN DUPLICATE), LISTING EACH TAGGED VALVE BY LOCATION, SERVICE, AND TAG DESCRIPTION. INSTALL ONE COPY OF EACH PAGE OF THE VALVE SCHEDULE IN GLAZED FRAMES, AND MOUNT WHERE DIRECTED. B. PROVIDE ONE (1) COPY OF SCHEDULE WITH OPERATION AND MAINTENANCE MANUALS. PIPE AND PIPE FITTINGS DESCRIPTION A. LISTED UNDER THIS SECTION IS ALL PIPING REQUIRED FOR THE SANITARY TRANSMISSION OF ALL FLUIDS. B. INCLUDED UNDER THIS SECTION IS ALL PIPING TO BE USED FOR HANDLING: 1. SANITARY WASTE AND VENT 2. DOMESTIC HOT AND COLD 3. CONDENSATE WASTE C. PIPE FITTINGS INCLUDE ALL COUPLINGS, TEES, WYES, ELBOWS, FLANGES, UNIONS, CONNECTORS, AND JOINTS REQUIRED FOR A COMPLETE INSTALLATION. PRODUCTS PVC PIPE AND FITTINGS A. SOLID-WALL PVC PIPE: ASTM D 2665, DRAIN, WASTE, AND VENT. B. PVC SOCKET FITTINGS: ASTM D 2665, MADE TO ASTM D 3311, DRAIN, WASTE, AND VENT PATTERNS AND TO FIT SCHEDULE 40 PIPE. C. ADHESIVE PRIMER: ASTM F 656. 1. ADHESIVE PRIMER SHALL HAVE A VOC CONTENT OF 550 g/L OR LESS WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24). 2. ADHESIVE PRIMER SHALL COMPLY WITH THE TESTING AND PRODUCT REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF HEALTH SERVICES "STANDARD PRACTICE FOR THE TESTING OF VOLATILE ORGANIC EMISSIONS FROM VARIOUS SOURCES USING SMALL-SCALE ENVIRONMENTAL CHAMBERS." D. SOLVENT CEMENT: ASTM D 2564. 1. PVC SOLVENT CEMENT SHALL HAVE A VOC CONTENT OF 510 g/L OR LESS WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24). 2. SOLVENT CEMENT SHALL COMPLY WITH THE TESTING AND PRODUCT REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF HEALTH SERVICES "STANDARD PRACTICE FOR THE TESTING OF VOLATILE ORGANIC EMISSIONS FROM VARIOUS SOURCES USING SMALL-SCALE ENVIRONMENTAL CHAMBERS." INSTALLATION A. SANITARY PIPING (WASTE AND VENT) 1. PROVIDE PVC PIPE AND FITTINGS FOR ALL SANITARY PIPING LOCATED BELOW THE FLOOR. 2. PROVIDE CAST IRON PIPE OR COPPER D.W.V. TUBING AND FITTINGS FOR ALL SANITARY PIPING ABOVE THE FLOOR. PVC PIPE AND FITTINGS MAY BE SUBSTITUTED AS A COST SAVINGS MEASURE. COPPER TUBING IS NOT ALLOWED FOR URINAL WASTE. 3. PROVIDE SECURE SUPPORTS FOR HORIZONTAL RUNS AND FOR VERTICAL RUNS IN SUSPENDED PIPING. 4. USE 1/8 BENDS WHEREVER THE PIPING CHANGES DIRECTION. 5. USE "NO-HUB" JOINTS FOR ALL CAST IRON PIPE INSTALLED INSIDE THE BUILDING, WHERE NOT INSTALLED IN THE GROUND. 6. PROVIDE STAINLESS STEEL SHIELD AND CLAMP ASSEMBLY ON ALL "NO-HUB" JOINTS. B. POTABLE WATER 1. PROVIDE TYPE 'L' COPPER TUBE AND VIEGA PROPRESS FITTINGS FOR THE ENTIRE SYSTEM. 2. INCLUDED UNDER THIS SPECIFICATION SHALL BE COLD WATER, HOT WATER AND HOT WATER RECIRCULATION PIPING. PIPING SPECIALTIES AND ACCESSORIES A. WATER SHOCK ABSORBERS 1. SHOCK ABSORBERS SHALL HAVE PRE-CHARGED AIR CHAMBER PERMANENTLY CAPPED AND EPOXY SEALED FROM WATER SYSTEM. NPT SOLID HEX BRASS ADAPTER. THEY SHALL BE SUITABLE FOR VERTICAL OR HORIZONTAL INSTALLATION IN CONCEALED LOCATIONS. 2. SHOCK ABSORBERS TO BE SIZED IN ACCORDANCE WITH PLUMBING AND DRAINAGE INSTITUTE "STANDARD P.D.I. -WH201" OR MANUFACTURER'S "FIXTURE-UNIT RATING TABLE." 3. DESIGN BASIS: REFER TO SCHEDULE. B. CLEANOUTS 1. MATERIALS: SAME AS PIPING IN WHICH THEY ARE INSTALLED. 2. WALL TYPE, FINISHED AREAS: (WPCO) a. CAULKING FERRULE: PVC (FOR SOIL PIPE). b. PLUG: TAPERED THREAD, BRONZE, COUNTERSUNK. c. ACCESS COVERPLATE: ROUND POLISHED NIKOLOY SECURE TO PLUG BY COUNTER SCREW. 3. WALL TYPE, UNFINISHED AREAS: a. MATERIAL: SAME AS PIPING IN WHICH THEY ARE INSTALLED. b. PLUG: COUNTERSUNK. INSTALLATION A. WATER SHOCK ABSORBERS 1. PROVIDE AT THE TOPS OF ALL RISERS AND AT THE END OF ALL RUNS IN EXCESS OF 50'-0", IN ALL HOT AND COLD WATER PIPING. 2. PROVIDE AT THE END OF ALL LINES SERVING A GROUP OF FIXTURES. 3. INSTALL IN ACCESSIBLE LOCATIONS. 4. SIZING AND SELECTION SHALL BE IN ACCORDANCE WITH "STANDARD P.D.I.-WH201" AND AS RECOMMENDED BY THE MANUFACTURER. B. CLEANOUTS 1. PROVIDE IN ALL SANITARY PIPING INSTALLED IN THE BUILDING SPACED A MAXIMUM OF 100 FEET ON CENTER AND AT ALL CHANGES IN DIRECTION OF PIPING GREATER THAN 45 DEGREES. 2. PROVIDE AT END OF ALL RUNS AND WHERE SHOWN ON THE DRAWINGS. 3. INSTALL CLEANOUTS IN SUCH A MANNER THAT ALL PIPING MAY BE READILY REACHED FOR PURPOSES OF CLEANING. 4. CLEANOUTS SHALL BE OF THE SAME NOMINAL SIZE AS THE PIPE, BUT NEED NOT BE LARGER THAN 4 INCHES. 5. PROVIDE AT THE BOTTOM OF ALL STACKS AND CONDUCTORS. VALVES A. BALL VALVES 1. 2 INCHES AND SMALLER: a. MATERIAL: TWO PIECE BODY, FULL PORT FORGED BRASS, STAINLESS STEEL BALL AND STEM. b. TYPE: FULL PORT EQUAL TO THE CONNECTING PIPE SIZE, NO LUBRICATION REQUIRED, TWO WAY FLOW, QUARTER TURN HANDLE FOR ON-OFF, TWO PIECE BODY, BRONZE CONSTRUCTION RATED AT 600 PSI WOG, THREADED OR SOLDERED FEMALE CONNECTION ENDS AS DETERMINED BY CONNECTING PIPING. VALVE SHALL COMPLY WITH FED. SPEC. WWV-35, TYPE II, CLASS A, STYLE 3, TESTED PER MSS-SP-72. PROVIDE 2 INCH STEM EXTENSIONS FOR INSULATED PIPE. c. DESIGN BASIS: WATTS SERIES FBV-3-SS/FBVS-3-SS, OR APPROVED EQUAL BY MILWAUKEE, NIBCO, APOLLO, WATTS, OR HAMMOND. B. EXECUTION 1. PROVIDE IN WATER PIPING AT ALL FIXTURES AND PLUMBING EQUIPMENT WHETHER THE EQUIPMENT IS PROVIDED BY THE PLUMBING CONTRACTOR OR BY OTHERS. STOPS PROVIDED WITH FIXTURES ARE CONSIDERED ACCEPTABLE. 2. BALL VALVES SHALL BE USED FOR WATER SERVICE, UNLESS OTHERWISE DIRECTED. 3. PROVIDE AT EACH BRANCH LINE SUPPLYING A GROUP OF FIXTURES. PLUMBING INSULATION A. STYLE: OWENS-CORNING FIBERGLASS 25 ASJ OR APPROVED EQUAL BY ARMSTRONG, CERTAINTEED, OR KNAUF. PROVIDE MINIMUM CONDUCTIVITY COMPLIANT WITH NEW YORK STATE ENERGY CODE. FITTING AND VALVE INSULATION A. PROVIDE PRE-SIZED FIBERGLASS INSULATION INSERTS WITH PVC PREFABRICATED FITTING COVERS. B. PVC INSULATED FITTING COVERS 1. PROVIDE PREFABRICATED FITTING COVERS IN CONJUNCTION WITH FIBERGLASS INSULATION INSERTS ON ALL PIPIE FITTINGS. C. MATERIAL: PVC D. TEMPERATURE RANGE: 0°F TO 450°F PIPING A. INSULATION THICKNESS SHALL BE AS FOLLOWS: 1. PIPING 1/2" TO 1 1/2" IN DIAMETER: 1" 2. PIPING 2" TO 8" IN DIAMETER: 1 1/2" B. PROVIDE INSULATION ON THE FOLLOWING PIPING SYSTEMS: 1. DOMESTIC COLD WATER PIPING 2. DOMESTIC HOT WATER PIPING 3. DOMESTIC HOT WATER RECIRCULATION PIPING 4. STORM WATER PIPING INCLUDING ROOF DRAIN BODIES PRODUCTS PLUMBING FIXTURES AND TRIM (REFER TO ARCHITECTURAL DRAWINGS FOR RIM HEIGHTS) WATER CLOSET (WC-1) 1. DESCRIPTION: 1.28 GPF FLUSH VALVE, 10-INCH ROUGH-IN 2. MOUNTING: FLOOR MOUNTED 3. OUTLET: FLOOR 4. COLOR: WHITE 5. CONSTRUCTION: VITREOUS CHINA, ELONGATED BOWL, SIPHON JET, 1 1/2" TOP SPUD 6. SEAT: CHURCH #295SSCT, ELONGATED, WHITE OPEN FRONT, LESS COVER, WITH CHECK HINGES 7. FLUSH VALVE: SLOAN ROYAL #111-1.28-YO 8. SENSOR FLUSHOMETER: SLOAN EVB200A-1.6 9. DESIGN BASIS: AMERICAN STANDARD #2234.001 MADERA FLOWISE OR APPROVED EQUAL. WATER CLOSET (WC-2) -ADA COMPLIANT 1. DESCRIPTION: 1.28 GPF FLUSH VALVE, 10-INCH ROUGH-IN 2. MOUNTING: FLOOR MOUNTED 3. OUTLET: FLOOR 4. COLOR: WHITE 5. CONSTRUCTION: VITREOUS CHINA, ELONGATED BOWL, SIPHON JET, 1 1/2" TOP SPUD 6. SEAT: CHURCH #295SSCT, ELONGATED, WHITE OPEN FRONT, LESS COVER, WITH CHECK HINGES. 7. FLUSH VALVE: SLOAN ROYAL #111-1.28-YO 8. SENSOR FLUSHOMETER: SLOAN EVB200A-1.6 9. DESIGN BASIS: AMERICAN STANDARD #3043.001 MADERA FLOWISE OR APPROVED EQUAL. NOTE: FLUSH VALVE HANDLE MUST BE INSTALLED TOWARDS THE WIDE SIDE OF THE TOILET STALL TO COMPLY WITH ADA REQUIREMENTS. REFER TO PLANS FOR LEFT OR RIGHT HAND INSTALLATION. URINAL (UR-1) 1. DESCRIPTION: MANUAL 0.5 GPF FLUSH VALVE. 2. MOUNTING: WALL HUNG 3. COLOR: WHITE 4. CONSTRUCTION: VITREOUS CHINA, WASHOUT FLUSH, INTEGRAL TRAP, 3/4 TOP SPUD, CONCEALED HANGER, 2" I.P.S. OUTLET CONNECTION. 5. FLUSH VALVE: SLOAN #186-0.5 6. SENSOR FLUSHOMETER: SLOAN EVB200A-1.6 7. FIXTURE SUPPORT: JAY R. SMITH #637 SERIES. 8. DESIGN BASIS: AMERICAN STANDARD #6590.001 WASHBROOK OR APPROVED EQUAL. LAVATORY (LAV-1) 1. DESCRIPTION: COMPACT 17 3/4" x 9 7/8" 2. MOUNTING: WALL HUNG 3. COLOR: WHITE 4. CONSTRUCTION: VITREOUS CHINA, SINGLE FAUCET HOLE, WALL BRACKET MOUNTING. 5. TRIM: MOEN #84505 CHROME. 6. GRID STRAINER: MCGUIRE #155WC OFFSET. 7. SUPPLY PIPES: KOHLER #K-7601, LOOSE KEY STOPS. 8. TRAP: KOHLER #K-9000 CAST BRASS, ADJUSTABLE, WITH C.O. PLUG, TUBING OUTLET, AND WALL FLANGE. 9. FIXTURE SUPPORT: MANUFACTURER SUPPLIED WALL BRACKET. 10. DESIGN BASIS: DURAVIT #070225 VERO HANDRINSE BASIN OR APPROVED EQUAL. LAVATORY (LAV-2) ADA COMPLIANT (TRIM ONLY) 1. DESCRIPTION: SOLID SURFACE WITH INTEGRAL BOWL -SINGLE BOWL. 2. MOUNTING: INTEGRAL BOWL 3. CONSTRUCTION: SOLID SURFACE TOP WITH INTEGRAL BOWL AND 4" FAUCET CENTERS BY GENERAL CONSTRUCTION TRADE. 4. TRIM: MOEN #8413F15 (ONE REQUIRED) 5. GRID STRAINER: MCGUIRE #155WC OFFSET. 6. SUPPLY PIPES: KOHLER #K-7601, LOOSE KEY STOPS. 7. TRAP: KOHLER #K-9000 CAST BRASS, ADJUSTABLE, WITH C.O. PLUG, TUBING OUTLET, AND WALL FLANGE. 8. DESIGN BASIS: BASIN BY GENERAL CONSTRUCTION TRADE. LAVATORY (LAV-3) (TRIM ONLY) 1. DESCRIPTION: SOLID SURFACE WITH INTEGRAL BOWL -THREE BOWL. 2. MOUNTING: INTEGRAL BOWL 3. CONSTRUCTION: SOLID SURFACE, 4" FAUCET CENTERS. 4. TRIM: MOEN #8413F15 (THREE REQUIRED) 5. GRID STRAINER: MCGUIRE #155WC OFFSET. 6. SUPPLY PIPES: KOHLER #K-7601, LOOSE KEY STOPS. 7. TRAP: KOHLER #K-9000 CAST BRASS, ADJUSTABLE, WITH C.O. PLUG, TUBING OUTLET, AND WALL FLANGE. 8. DESIGN BASIS: BASIN BY GENERAL CONSTRUCTION TRADE. LAVATORY (LAV-4) (TRIM ONLY) 1. DESCRIPTION: SOLID SURFACE WITH INTEGRAL BOWL -FOUR BOWL. 2. MOUNTING: INTEGRAL BOWL 3. CONSTRUCTION: SOLID SURFACE, 4" FAUCET CENTERS. 4. TRIM: MOEN #8413F15 (FOUR REQUIRED) 5. GRID STRAINER: MCGUIRE #155WC OFFSET. 6. SUPPLY PIPES: KOHLER #K-7601, LOOSE KEY STOPS. 7. TRAP: KOHLER #K-9000 CAST BRASS, ADJUSTABLE, WITH C.O. PLUG, TUBING OUTLET, AND WALL FLANGE. 8. DESIGN BASIS: BY GENERAL CONSTRUCTION TRADE. SHOWER (SH-1) 1. DESCRIPTION: ONE PIECE SHOWER BASE 32”X 32” 2. MOUNTING: FLOOR SET. SET IN A MORTAR BASE AND SHIM AS NECESSARY TO LEVEL. 3. CONSTRUCTION: ONE-PIECE, SINGLE THRESHOLD SOLID SURFACE SEAMLESS UNIT WITH MOLDED-IN DRAIN. 4. ACCESSORIES: 10-OZ GSA APPROVED SHOWER CURTAIN WITH CURTAIN HOOKS. 2" CAST BRASS CHROME PLATED SHOWER DRAIN, AND 1" DIAMETER STAINLESS STEEL CURTAIN ROD. 5. DESIGN BASIS: BRADLEY #WS-1X-HD-B-ST-SD-SL-NO SHROUD-VS AND SWANSTONE #R-3232 SHOWER PAN. SHOWER (SH-2) 1. DESCRIPTION: 1.5 GPM STAINLESS STEEL SHOWER PANEL SYSTEM. 2. MOUNTING: SURFACE MOUNTED ON WALL. 3. DESIGN BASIS: BRADLEY #WS-1X-HD-B-ST-SD-SL-NO SHROUD-VS. SHOWER (SH-3) 1. DESCRIPTION: ONE PIECE SHOWER BASE 32”X 60” 2. MOUNTING: FLOOR SET. SET IN A MORTAR BASE AND SHIM AS NECESSARY TO LEVEL. 3. CONSTRUCTION: ONE-PIECE, SINGLE THRESHOLD SOLID SURFACE SEAMLESS UNIT WITH MOLDED-IN DRAIN. 4. ACCESSORIES: 10-OZ GSA APPROVED SHOWER CURTAIN WITH CURTAIN HOOKS. 2" CAST BRASS CHROME PLATED SHOWER DRAIN, AND 1" DIAMETER STAINLESS STEEL CURTAIN ROD. 5. DESIGN BASIS: BRADLEY #WS-1X-HD-B-ST-SD-SL-NO SHROUD-VS AND SWANSTONE #R-3260 SHOWER PAN. HOSE BIBB (HB-1) (HOT/COLD) 1. DESCRIPTION: INTERIOR. 2. MOUNTING: THREADED 3. CONSTRUCTION: BRONZE BODY WITH 1/4 TURN VALVE ACTION 4. SIZE: 3/4" 5. DESIGN BASIS: WOODFORD #C22 WITH LOOSE KEY HANDLES OR APPROVED EQUAL. INSTALLATION A. FURNISH AND INSTALL ALL PRODUCTS. B. INSTALL ALL PRODUCTS LEVEL AND PLUMB. C. FURNISH AND INSTALL CHROME PLATED PIPING, FITTINGS, VALVES, ESCUTCHEONS, TRIM, ETC. FOR FIXTURE CONNECTIONS WHICH ARE EXPOSED TO VIEW. D. INSTALL ALL FIXTURES AT MOUNTING HEIGHTS AND LOCATIONS AS SHOWN IN DRAWINGS AND SPECIFICATIONS. E. PROVIDE MOUNTING SUPPORTS FOR ALL PRODUCTS. F. INSTALL ALL TRIM AND ACCESSORIES, PROVIDING ADEQUATE WALL SUPPORTS BEHIND ALL WALL MOUNTED COMPONENTS. G. SEAL PERIMETER JOINTS OF FIXTURES WITH SEALANT RECOMMENDED BY FIXTURE MANUFACTURER FOR THE LOCATIONS AND MOUNTING SURFACES INDICATED. HANGER ROD INSULATION PROVIDE HIGH COMPRESSIVE STRENGTH INSULATION INSERT BETWEEN PIPE AND INSULATION SHIELD INSULATION SHIELD AT HANGER ADJUSTABLE CLEVIS HANGER TRAPEZE HANGER FOR UP TO 1,000 LBS UNIFORM LOAD 1/2" DIAMETER HANGER RODS WITH 36" MAXIMUM SPACING ON EACH CHANNEL PROVIDE INSULATIION SHIELD AND INSERT FOR ALL PIPING BAND 1 5/8" 12 GAUGE CHANNEL OR 2" x 2" x 1/4" ANGLE BALL VALVE 1/2" TRAP PRIMER SUPPLY DOMESTIC WATER LINE TRAP PRIMER VALVE DESIGN BASIS: WATTS #LFTP300 1/2" TRAP PRIMER LINE TO FLOOR DRAIN FLOOR SLAB SLEEVE THRU SLAB NOTE: 1. TRAP PRIMER SHALL BE LOCATED IN ACCESSIBLE LOCATION. MINIMUM SIZE OF PIPING SHALL BE 1/2". 2. TRAP PRIMER WITH DISTRIBUTION UNIT SHALL BE USED TO SERVE MULTIPLE FLOOR DRAINS. 3. PROVIDE ADDITIONAL TRAP PRIMER VALVE AND DISTRIBUTION UNIT IF NUMBER OF DRAINS EXCEEDS MAXIMUM NUMBER OF LINES SERVED BY DISTRIBUTION UNIT. Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. ©Filename:Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE no. revision description by date 4/13/2020 11:13:08 AMC:\Projects\BEAR-A-19100-V2018_nhavrish.rvtALL TRADES Cornell UniversityG-003 04.15.2020 PLUMBING SPECIFICATIONS, SCHEDULES AND DETAILSZeta Psi Bathroom Renovations534 Thurston Avenue Ithaca, NY 14850DJW 19100 NRH/MAR DJW 2020 PLUMBING FIXTURE SCHEDULE FIXTURE NUMBER FIXTURE DESCRIPTION COLD HOT WASTE VENT NOTES WC-1 WATER CLOSET - FLOOR MOUNTED/FLUSH VALVE 1" - 4" 2" REFER TO SPECIFICATION FOR ADDITIONAL COMPONENTS WC-2 WATER CLOSET - ADA - FLOOR MOUNTED/FLUSH VALVE 1" - 4" 2" REFER TO SPECIFICATION FOR ADDITIONAL COMPONENTS UR-1 URINAL - WALL MOUNTED/FLUSH VALVE 3/4" - 2" 1-1/2" REFER TO SPECIFICATION FOR ADDITIONAL COMPONENTS LAV-1 LAVATORY - WALL HUNG - COMPACT 1/2" 1/2" 1-1/2" 1-1/2"1.2 GPM LAV-2 LAVATORY - ADA - SOLID SURFACE - INTEGRAL BOWL - SINGLE BOWL 1/2" 1/2" 1-1/2" 1-1/2"1.5 GPM LAV-3 LAVATORY - SOLID SURFACE - INTEGRAL BOWL - THREE BOWL 1/2" 1/2" 1-1/2" 1-1/2"1.5 GPM LAV-4 LAVATORY - SOLID SURFACE - INTEGRAL BOWL - FOUR BOWL 1/2" 1/2" 1-1/2" 1-1/2"1.5 GPM SH-1 SHOWER - SHOWER BASE W/STAINLESS STEEL WALL PANEL 1/2" 1/2" 2" 1-1/2"1.5 GPM SH-2 SHOWER - STAINLESS STEEL WALL PANEL 1/2" 1/2" - -1.5 GPM SH-3 SHOWER - SHOWER BASE W/STAINLESS STEEL WALL PANEL 1/2" 1/2" 2" 1-1/2"1.5 GPM HB-1 HOSE BIBB - INTERIOR 3/4" - - - FLOOR DRAIN SCHEDULE FLOOR DRAIN SIZE MATERIAL DESIGN BASIS MODEL #NOTESMANUFACTURER FD-1 3" NICKEL BRONZED JAY R SMITH 2005A-P PROVIDE DEEP SEAL P-TRAP AND TRAP PRIMER CONNECTION SCALE:NOT TO SCALE1TYPICAL PIPE HANGER DETAIL SCALE:NOT TO SCALE2TYPICAL TRAP PRIMER VALVE DETAIL GENERAL PLUMBING NOTES A INFORMATION, SUCH AS SIZE, LOCATION OR INVERTS OF EXISTING CONCEALED SERVICES, IS APPROXIMATE AND BASED ON REPUTED INFORMATION FROM EXISTING DRAWINGS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE INFORMATION IN THE FIELD. B PROVIDE 1/4" PER FOOT SLOPE FOR ALL SANITARY AND STORM WATER LINES WITHIN THE BUILDING UNLESS OTHERWISE NOTED. C COORDINATE LOCATION AND ROUTING OF PLUMBING LINES WITH OTHER TRADES. D PROVIDE FIRE PROOFING FOR ALL FLOOR PENETRATIONS AND ALL PENETRATIONS THROUGH RATED WALLS. E PROVIDE WATER SAVER TYPE PLUMBING FIXTURES. F PROVIDE EASILY ACCESSIBLE CLEANOUTS AT THE BOTTOM OF ALL WASTE AND SOIL STACKS. G PROVIDE EASILY ACCESSIBLE CLEANOUTS AT ALL CHANGES IN DIRECTION GREATER THAN 45° AS WELL AS WHERE SHOWN ON PLANS. H PROVIDE EASILY ACCESSIBLE SHUTOFFS ON ALL BRANCH LINES, AND PROVIDE STOPS ON ALL FIXTURES. I CONTRACTOR MAY COMBINE PLUMBING VENTS AND MAY CONNECT TO EXISTING VENTS THROUGH ROOF PROVIDING THEY ARE ADEQUATE SIZE. J PROVIDE ALL WORK IN ACCORDANCE WITH THE PLUMBING CODE OF NEW YORK STATE, THE NATIONAL STANDARD PLUMBING CODE, NEW YORK STATE DEPARTMENT OF HEALTH CROSS CONNECTION CONTROL MANUAL, AND ANY LOCAL CODES THAT MAY TAKE PRECEDENCE. K PROVIDE CONNECTIONS TO SERVICES PROVIDED BY OTHER CONTRACTORS, UNLESS OTHERWISE NOTED. L PROVIDE ALL PERMITS AND TESTING REQUIRED. M PROVIDE INSULATION AT HOT WATER SUPPLY AND DRAIN AT LAVATORIES. SECTION 21 13 13 -WET-PIPE FIRE SPRINKLER SYSTEM PART 1 -GENERAL 1.1 PERFORMANCE REQUIREMENTS A. PROVIDE MODIFICATION TO AN EXISTING WET-PIPE SPRINKLER SYSTEM. B. STANDARD-PRESSURE PIPING SYSTEM COMPONENTS: LISTED FOR 175-PSIG (1200 KPA) MINIMUM WORKING PRESSURE. C. DESIGN SPRINKLER SYSTEM(S) USING INDICATED PIPE SIZES, PERFORMANCE REQUIREMENTS, AND DESIGN CRITERIA INDICATED. D. SPRINKLER SYSTEM DESIGN SHALL BE APPROVED BY AUTHORITIES HAVING JURISDICTION. E. SPRINKLER OCCUPANCY HAZARD CLASSIFICATION: LIGHT HAZARD 1.2 SUBMITTALS A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED INCLUDE RATED CAPACITIES, OPERATING CHARACTERISTICS, AND FURNISHED SPECIALTIES AND ACCESSORIES. B. SHOP DRAWINGS: FOR WET-PIPE SPRINKLER SYSTEMS. INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS, TRADE COORDINATION AND ATTACHMENTS TO OTHER WORK. PREPARE IN ACCORDANCE WITH NFPA 13 FOR APPROVAL BY AUTHORITY HAVING JURISDICTION. C. FIELD TEST REPORTS AND CERTIFICATES: INCLUDE "CONTRACTOR'S MATERIAL AND TEST CERTIFICATE FOR ABOVE GROUND PIPING." 1.3 PROJECT CONDITIONS A. INTERRUPTION OF EXISTING SPRINKLER SERVICE: DO NOT INTERRUPT SPRINKLER SERVICE TO FACILITY UNLESS PERMITTED UNDER THE FOLLOWING CONDITIONS AND THEN ONLY AFTER ARRANGING TO PROVIDE TEMPORARY SPRINKLER SERVICE ACCORDING TO REQUIREMENTS INDICATED: 1. NOTIFY EH&S AND ITHACA FIRE DEPARTMENT NO FEWER THAN TWO DAYS IN ADVANCE OF PROPOSED INTERRUPTION OF SPRINKLER SERVICE. PART 2 -PRODUCTS 2.1 STEEL PIPE AND FITTINGS A. STANDARD WEIGHT, SCHEDULE 40, BLACK-STEEL PIPE: ASTM A53/A53M, TYPE F, GRADE A. PIPE ENDS MAY BE FACTORY OR FIELD FORMED TO MATCH JOINING METHOD. B. BLACK-STEEL PIPE NIPPLES: ASTM A733, MADE OF ASTM A53/A53M, STANDARD WEIGHT, SEAMLESS STEEL PIPE WITH THREADED ENDS. C. UNCOATED, GRAY-IRON THREADED FITTINGS: ASME B16.4, CLASS 125, STANDARD PATTERN. D. GROOVED-JOINT, STEEL-PIPE APPURTENANCES: 1. UNCOATED, GROOVED-END FITTINGS FOR STEEL PIPING: ASTM A47/A47M, MALLEABLE IRON CASTING OR ASTM A536, DUCTILE-IRON CASTING; WITH DIMENSIONS MATCHING STEEL PIPE. 2. GROOVED-END-PIPE COUPLINGS FOR STEEL PIPING: AWWA C606 AND UL 213, RIGID PATTERN UNLESS OTHERWISE INDICATED. FOR STEEL-PIPE DIMENSIONS, INCLUDE FERROUS HOUSING SECTIONS, EPDM-RUBBER GASKET, AND BOLTS AND NUTS. 2.2 SPRINKLERS A. AUTOMATIC LISTED RESIDENTIAL SIDE WALL SPRINKLERS MATCHING MANUFACTURER OF EXISTING. 1. CHARACTERISTICS: NOMINAL 1/2-INCH (12.7-MM) ORIFICE WITH DISCHARGE COEFFICIENT K OF 5.6, AND FOR "ORDINARY" TEMPERATURE CLASSIFICATION RATING. B. SPRINKLER FINISHES: 1. WHITE. PART 3 -EXECUTION 3.1 PIPING INSTALLATION A. LOCATIONS AND ARRANGEMENTS: DRAWING PLANS AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT OF PIPING. INSTALL PIPING AS INDICATED, AS FAR AS PRACTICAL. B. PIPING STANDARD: COMPLY WITH REQUIREMENTS FOR INSTALLATION OF SPRINKLER PIPING IN NFPA 13. C. PAINT NEW EXPOSED PIPE, FITTINGS, AND HANGERS TO MATCH EXISTING. 3.2 FIELD QUALITY CONTROL A. TEST AND INSPECTIONS: 1. CONDUCT TESTING WITH EH&S AND ITHACA FIRE DEPARTMENT. SCHEDULE TESTING THROUGH DAN PHILLIPS AT EH&S. 2. LEAK TEST: AFTER INSTALLATION, CHARGE SYSTEM AND TEST FOR LEAKS. REPAIR LEAKS AND RETEST UNTIL NO LEAKS EXIST. 3. TEST AND INSPECT SPRINKLER SYSTEM ACCORDING TO NFPA 13, "SYSTEMS ACCEPTANCE" CHAPTER. B. SPRINKLER PIPING SYSTEM WILL BE CONSIDERED DEFECTIVE IF IT DOES NOT PASS TESTS AND INSPECTIONS. C. PREPARE TEST AND INSPECTION REPORTS. 3.3 CLEANING A. CLEAN DIRT AND DEBRIS FROM SPRINKLERS. B. REMOVE AND REPLACE SPRINKLERS WITH PAINT OTHER THAN FACTORY FINISH. Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. ©Filename:Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE no. revision description by date 4/13/2020 11:13:08 AMC:\Projects\BEAR-A-19100-V2018_nhavrish.rvtALL TRADES Cornell UniversityG-004 04.15.2020 HVAC & FIRE SUPPRESSION SPECIFICATIONSZeta Psi Bathroom Renovations534 Thurston Avenue Ithaca, NY 14850NRH/MAG 19100 NRH/MAR MAG/GAH 2020 MECHANICAL SPECIFICATIONS 5. PERFORMANCE: PERFORM WORK AS TO AVOID DAMAGE TO WORK OR EXISTING INSTALLATIONS TO REMAIN. PROVIDE ADEQUATE SURFACES TO RECEIVE PATCHING AND FINISHING. EMPLOY OWNER APPROVED INSTALLER TO PERFORM CUTTING AND PATCHING MATERIALS THAT ARE EXPOSED TO WEATHER, ARE MOISTURE RESISTANT OR ARE EXPOSED TO VIEW. CUT RIGID MATERIALS WITH MASONRY SAW OR CORE DRILL. USE OF PNEUMATIC TOOLS IS NOT ALLOWED WITHOUT WRITTEN PRIOR APPROVAL. RESTORE AND REPAIR WORK WITH NEW PRODUCTS OR MATERIALS IN ACCORDANCE WITH REQUIREMENTS OF CONTRACT DOCUMENTS. INTEGRATE PIPES, SLEEVES, DUCTS, CONDUIT, AND OTHER PENETRATIONS WITH NEW AND EXISTING WORK NEATLY THROUGH THE SURFACES OF SUCH WORK. ALL FIRE-RATED WALLS, PARTITIONS, CEILINGS OR FLOOR CONSTRUCTION THAT ARE PENETRATED SHALL BE COMPLETELY SEALED WITH REQUIRED FIRE-RATED MATERIAL TO THE FULL THICKNESS OF THE PENETRATED CONSTRUCTION. REFINISH SURFACES TO MATCH ADJACENT FINISHES. FOR CONTINUOUS SURFACES, REFINISH TO NEAREST INTERSECTION OR NATURAL BREAK. FOR AN ASSEMBLY, COMPLETELY REFINISH. 6. CONTRACTOR SHALL PERFORM ALL DEMOLITION, CUTTING AND PATCHING UNLESS INDICATED OTHERWISE, EVEN IF NOT EXPLICITLY INDICATED ON DRAWINGS. DEMOLITION, CUTTING AND PATCHING INCLUDES REMOVAL OF EQUIPMENT THAT WILL NO LONGER BE UTILIZED FOR PROJECT. EQUIPMENT TO BE REMOVED SHALL BE TURNED OVER TO OWNER UNLESS OWNER DOES NOT WANT EQUIPMENT, IN WHICH CASE CONTRACTOR SHALL REMOVE FROM SITE. 7. ALL OPENINGS, FLASHING AND COUNTER FLASHING SHALL BE PROVIDED BY CONTRACTOR. H. SUPPORTS AND HANGERS: 1. HANGERS AND SUPPORTS ARE TO BE PROVIDED TO PROPERLY SUPPORT, SECURE AND ALIGN PIPING, AND TO MEET FIELD CONDITIONS AND AS MANUFACTURED BY GRINNELL OR MICHIGAN. 2. HANGERS AND SUPPORTS: PROVIDE ALL HANGERS AND SUPPORTS FOR EQUIPMENT, PIPING AND DUCTWORK. COMPLY WITH ALL CODES AND REGULATIONS PERTAINING TO PRODUCT MATERIALS AND INSTALLATION, SMACNA, INTERNATIONAL CODE COUNCIL, NFPA, UL FM, NRTL AND NEMA. PROVIDE HANGERS, RODS AND SHIELD INSERTS ALONG WITH CLAMPS, BOLTS, NUTS, WASHERS, PROTECTION SADDLES AND OTHER ACCESSORIES. PROVIDE STRUCTURAL STEEL FOR ATTACHMENT TO EXISTING STRUCTURAL MEMBERS REQUIRED FOR HANGER ATTACHMENT. I. WIRING: 1. FURNISH AND INSTALL ALL ACTUATING DEVICES WHICH REQUIRE ELECTRICAL CONNECTION (SUCH AS PUSH-BUTTON STATIONS, WALL-MOUNTED ELECTRICAL CONTACTING THERMOSTATS, ETC.,) INCLUDING MOUNTING AND CONNECTION. 2. PROVIDE NECESSARY INFORMATION, SUPERVISION, AND COORDINATION AS REQUIRED TO IMPLEMENT THE WIRING DIAGRAMS AND OTHER INFORMATION FOR THE WORK. 3. FURNISH AND INSTALL AUTOMATIC CONTROL WIRING BELOW 100 VOLT. WIRING SHALL CONFORM TO THE NATIONAL ELECTRIC CODE AND TO AND LOCAL AND/OR STATE CODES THAT APPLY. J. MECHANICAL/ELECTRICAL COORDINATION: 1. ALL PIPING SHALL BE KEPT A MINIMUM OF 3 FEET AWAY FROM AND NOT RUN ABOVE ANY ELECTRICAL ENCLOSURES OR EQUIPMENT. 2. CONTRACTOR SHALL FURNISH AND INSTALL STARTERS AND DISCONNECTS FOR ALL EQUIPMENT SUPPLIED UNLESS OTHERWISE INDICATED. FINAL ELECTRICAL CONNECTIONS SHALL BE MADE BY CONTRACTOR. 3. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONTROL WIRING, CONDUITS AND MATERIALS REQUIRED TO PROVIDE COMPLETE HVAC CONTROL SYSTEMS, INCLUDING PROGRAMMING. K. SUBMITTALS: PRIOR TO ANY INSTALLATIONS, SUBMIT FOR REVIEW SHOP DRAWINGS AND CATALOG DATA FOR MATERIALS AND EQUIPMENT INCLUDING THOSE THAT ARE SUBSTITUTIONS TO CONTRACT DOCUMENTS. L. PROJECT/SITE CONDITIONS: DRAWINGS INDICATE APPROXIMATE LOCATIONS OF UTILITIES AND EXISTING INSTALLATIONS AND SERVICES. IT IS THE RESPONSIBILITY OF CONTRACTOR TO VERIFY, IN THE FIELD, EXACT LOCATIONS OF ALL SUCH UTILITIES. CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS OF LOCAL UTILITY COMPANIES AND FACILITY OWNER. CONTRACTOR SHALL INCLUDE IN BID, PRICES FOR VALVES, METER BOXES, METERS AND ANY OTHER EQUIPMENT THAT UTILITY COMPANIES OR FACILITY OWNER MAY REQUIRE. M. SYSTEMS START-UP: 1. VERIFY EACH PIECE OF EQUIPMENT OR SYSTEM HAS BEEN CHECKED FOR PROPER LUBRICATION, DRIVE ROTATION, BELT TENSION, CONTROL SEQUENCES, OR ANY OTHER CONDITIONS REQUIRING VERIFICATION PRIOR TO START-UP. PREVENT ANY POTENTIAL DAMAGE TO EQUIPMENT OR SYSTEMS CAUSED BY INADEQUATE OR INCORRECT START-UP PREPARATION. 2. EXECUTE START-UP UNDER SUPERVISION OF RESPONSIBLE AND QUALIFIED CONTRACTOR'S PERSONNEL, CERTIFIED IN START-UP OF EACH PIECE OF EQUIPMENT OR SYSTEM. CERTIFICATION SHALL BE IN ACCORDANCE WITH MANUFACTURERS REQUIREMENTS. 3. TEST, ADJUST AND BALANCE ALL EQUIPMENT AND SYSTEMS AS REQUIRED TO PROVIDE A COMPLETE AND CORRECTLY OPERATING SYSTEM IN ACCORDANCE WITH DESIGN DOCUMENTS. N. O&M MANUALS: COMPILE AND PROVIDE TO OWNER THE OWNERS MANUALS, WHICH SHALL INCLUDE PRODUCT DATA SHEETS,MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS, SHOP DRAWINGS, AS-BUILT DRAWINGS, BALANCE REPORTS, PRODUCT SERIAL AND MODEL NUMBERS, INSTALLATION DATES, WARRANTIES, WARRANTY EXPIRATION DATES, ETC. PROVIDE TWO (2) THUMB DRIVES WITH ALL O&M INFORMATION INCLUDED. MECHANICAL SPECIFICATIONS A. GENERAL: 1. PROVIDE ALL MATERIALS, EQUIPMENT, SUPPORTS, CONTROLS, WIRING, CONDUIT, LABOR, ETC. FOR COMPLETE INSTALLATION. COORDINATE WORK WITH ALL OTHER TRADES. INTERFERENCES, CONFLICTS, DISCREPANCIES, ETC. SHALL BE COORDINATED PRIOR TO START OF INSTALLATION. ALL CONFLICTS SHALL BE BROUGHT TO ATTENTION OF OWNER IMMEDIATELY, BEFORE PROCEEDING WITH WORK. WORK SHALL CONFORM TO REQUIREMENTS OF APPLICABLE GOVERNMENTAL REGULATIONS AND SHALL BEAR APPROVAL CERTIFICATES AS APPLICABLE. 2. REMOVAL AND RELOCATION OF CERTAIN EXISTING WORK SHALL BE NECESSARY FOR PERFORMANCE OF GENERAL WORK. ALL EXISTING CONDITIONS ARE NOT DETAILED ON DRAWINGS. SURVEY SITE AND MAKE ALL CHANGES REQUIRED BASED ON EXISTING CONDITIONS FOR INSTALLATION OF WORK, INCLUDE ALL MATERIALS AND LABOR IN BID PRICE. NO ALLOWANCE WILL BE MADE FOR FAILURE TO DO SO. 3. DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL ARRANGEMENT OF VENTILATION AND AIR CONDITIONING SYSTEMS. DETAILS OF CONSTRUCTION AND WORKMANSHIP WHERE NOT DESCRIBED HEREIN OR INDICATED ON DRAWINGS SHALL BE SUBJECT TO ENGINEER'S APPROVAL. THE INTENT OF THESE SPECIFICATIONS TO PROVIDE COMPLETE SYSTEMS, LEFT IN GOOD WORKING ORDER, READY FOR OPERATION, INCLUDING LABOR AND MATERIALS, WHETHER OR NOT SPECIFICALLY SHOWN ON DRAWINGS OR HEREIN. IT IS NOT THE INTENT TO SHOW ALL NECESSARY OFFSETS, OBSTRUCTIONS OR STRUCTURAL CONDITIONS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL WORK TO AVOID OBSTRUCTIONS, PRESERVE HEADROOM AND KEEP OPENINGS AND PASSAGEWAYS CLEAR WITHOUT FURTHER COST OR INSTRUCTIONS. 4. SUPPORT ALL DUCTWORK FROM BUILDING STRUCTURE AND/OR FRAMING IN APPROVED MANNER. WHERE OVERHEAD CONSTRUCTION DOES NOT PERMIT FASTENING OF SUPPORTS FOR EQUIPMENT, FURNISH ADDITIONAL FRAMING. 5. CONTRACTOR SHALL FURNISH AND INSTALL ALL ELECTRIC, AUTOMATIC CONTROLS AND CONTROLLERS. 6. BEFORE COMPLETION OF THIS PROJECT, CONTRACTOR SHALL TEST ALL EQUIPMENT. ALL EQUIPMENT SHALL BE OPERATED TO VERIFY THAT EACH UNIT PERFORMS SATISFACTORILY AND MEETS THE REQUIREMENTS SPECIFIED. 7. LOCATE EQUIPMENT AND ACCESSORIES TO PROVIDE EASY ACCESS FOR MAINTENANCE. 8. CONTRACTOR'S WORK SHALL INCLUDE HOISTING OF MATERIALS AND EQUIPMENT. 9. CONTRACTOR SHALL REPAIR AND RESTORE TO ORIGINAL CONDITION ANY EXISTING EQUIPMENT OR MATERIALS DAMAGED DURING INSTALLATION. B. GUARANTEE AND CERTIFICATION:CONTRACTOR SHALL GUARANTEE WORK PERFORMED AND MATERIALS INSTALLED TO BE FREE FROM DEFECTS AND SHALL REPLACE ANY DEFECTIVE MATERIAL OR WORKMANSHIP, FREE OF COST, FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE. C. QUALITY ASSURANCE: 1. CONTRACTOR SHALL MONITOR QUALITY CONTROL OVER SUPPLIERS, MANUFACTURERS, PRODUCTS, SERVICES, SITE CONDITIONS AND WORKMANSHIP, TO PRODUCE WORK OF SPECIFIED QUALITY. 2. FOLLOW MANUFACTURERS WRITTEN INSTRUCTIONS COMPLETELY. 3. WORK SHALL BE COMPLETED BY QUALIFIED PERSONNEL. 4. SECURE EQUIPMENT AND PROVIDE INSTALLATIONS COMPLETE WITH ANCHORING AND SUPPORT DEVICES DESIGNED TO HANDLE STRESSES, VIBRATION, PHYSICAL USE AND/OR ABUSE OF EQUIPMENT THAT INSTALLATION MAY EXPERIENCE. D. CODES AND REGULATIONS: 1. CONFORM TO ALL LOCALLY OBSERVED AND APPLICABLE BUILDING, MECHANICAL, PLUMBING AND FIRE PROTECTION CODES. 2. CONFORM TO LATEST EDITION OF NATIONAL FIRE PROTECTION STATE AND LOCAL CODES, AND ANY OTHER CODES HAVING JURISDICTION OVER THE PROJECT. 3. OBTAIN REQUIRED PERMITS AND REQUEST INSPECTIONS AS NECESSARY AND IN ACCORDANCE WITH EACH "AUTHORITY HAVING JURISDICTION". WORK SHALL MEET OR EXCEED LATEST REQUIREMENTS OF NATIONAL, STATE, COUNTY, MUNICIPAL, AND OTHER AUTHORITIES WITH JURISDICTION OVER CONSTRUCTION OF PROJECT. 4. ALL APPLICABLE CODES, LAWS AND REGULATIONS GOVERNING OR RELATING TO THIS WORK ARE INCORPORATED INTO THESE SPECIFICATIONS, AND PROVISIONS SHALL BE CARRIED OUT BY CONTRACTOR WHO SHALL INFORM OWNER, PRIOR TO SUBMITTING PROPOSAL, OF ANY WORK OR MATERIALS WHICH VIOLATE ANY OF THE ABOVE LAWS AND REGULATIONS. ANY WORK DONE BY CONTRACTOR CAUSING SUCH VIOLATION SHALL BE CORRECTED BY CONTRACTOR. 5. CONTRACTOR SHALL GIVE NECESSARY NOTICES, FILE DRAWINGS AND SPECIFICATIONS WITH ALL DEPARTMENTS HAVING JURISDICTION, AND OBTAIN ALL NECESSARY PERMITS AND CERTIFICATES, AND PAY ALL FEES AND CHARGES CONNECTED WITH. ALL CERTIFICATES SHALL BE DELIVERED TO OWNER PRIOR TO FINAL ACCEPTANCE. E. DEMOLITION: DISCONNECT AND REMOVE EXISTING HVAC FAN IN ENTIRETY. REFER TO DEMOLITION DRAWING FOR ADDITIONAL REQUIREMENTS. DISCONNECT AND REMOVE DUCTWORK AND ASSOCIATED MECHANICAL EQUIPMENT. F. CLEANING AND PROTECTION: 1. STORE AND PROTECT MATERIALS AND EQUIPMENT PER MANUFACTURER'S INSTRUCTIONS. CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO STORED EQUIPMENT AND MATERIALS DUE TO INADEQUATE OR INSUFFICIENT PROTECTION. STORE MATERIALS IN A MANNER THAT WILL MAINTAIN AN ORDERLY, CLEAN APPEARANCE. 2. INLET AND DISCHARGE OPENINGS OF ALL EQUIPMENT SHALL BE KEPT COVERED UNTIL EQUIPMENT IS READY TO RUN. 3. EQUIPMENT AND MATERIAL DAMAGED IS SUBJECT TO REJECTION AND REPLACEMENT. 4. DURING CONSTRUCTION, PROTECT ALL DUCTWORK, PIPING AND EQUIPMENT FROM DAMAGE AND DIRT. CAP OPENINGS OF ALL DUCTWORK, PIPING AND EQUIPMENT NOZZLES. 5. REMOVE WASTE MATERIALS, DEBRIS AND RUBBISH FROM SITE AND DISPOSE OFF-SITE. 6. AFTER COMPLETION OF PROJECT, CLEAN EXTERIOR SURFACES OF EQUIPMENT. G. CUTTING AND PATCHING: 1. CONTRACTOR SHALL PERFORM CUTTING AND PATCHING AS REQUIRED. CUTTING AND PATCHING SHALL CONFORM TO REQUIREMENTS OF BUILDING OWNER. 2. EXAMINATION: INSPECT EXISTING CONDITIONS PRIOR TO ANY WORK, INCLUDING ITEMS SUBJECT TO DAMAGE OR MOVEMENT DURING CUTTING AND PATCHING. AFTER UNCOVERING EXISTING WORK, INSPECT CONDITIONS AFFECTING NEW INSTALLATIONS. BEGINNING OF CUTTING AND PATCHING INDICATES CONTRACTOR'S ACCEPTANCE OF EXISTING CONDITIONS. 3. PREPARATION: PROVIDE TEMPORARY SUPPORTS AS TO ENSURE STRUCTURAL INTEGRITY OF WORK. PROVIDE DEVICES AND METHODS TO PROTECT OTHER PORTIONS OF PROJECT FROM DAMAGE. PROVIDE PROTECTION FROM WEATHER, DUST, DEBRIS, ETC. MAINTAIN EXCAVATIONS FREE FROM WATER. 4. CUTTING AND PATCHING: PERFORM CUTTING AND PATCHING INCLUDING ANY REQUIRED EXCAVATION AND FILL. FIT INSTALLATIONS TO INTEGRATE WITH OTHER WORK. REMOVE AND REPLACE DEFECTIVE OR NON-CONFORMING WORK. PROVIDE ALL OPENINGS AND PENETRATIONS REQUIRED. AIR DISTRIBUTION SYSTEM SPECIFICATIONS A. GENERAL: 1. FURNISH ALL MATERIALS, LABOR, EQUIPMENT AND ACCESSORIES REQUIRED TO INSTALL COMPLETE AIR DISTRIBUTION SYSTEMS. 2. CONTRACTOR SHALL VISIT SITE AND FAMILIARIZE WITH CONDITION AFFECTING THE WORK. SUBMISSION OF BID ON PROJECT SHALL BE CONSTRUED AS HAVING SUCH KNOWLEDGE. 3. VERIFY EXACT CONDITIONS IN FIELD AND COORDINATE WITH DRAWINGS AND OWNER BEFORE BEGINNING NEW WORK. 4. DETERMINE EXACT LOCATIONS FOR ALL DUCTWORK AND ACCESSORIES IN FIELD. 5. COORDINATE WORK WITH OTHER TRADES. 6. ANY DISCREPANCIES BETWEEN WHAT IS SHOWN ON DRAWINGS OR SPECIFIED AND ACTUAL CONDITIONS IN FIELD SHALL BE BROUGHT TO ATTENTION OF OWNER BEFORE PROCEEDING. 7. BUILDING AND SURFACES DAMAGED DURING INSTALLATION SHALL BE REPAIRED, REPLACED, AND/OR RESTORED TO ORIGINAL CONDITION AFTER COMPLETION OF WORK AND BEFORE ACCEPTANCE BY OWNER. B. SECTION 23 31 13: METAL DUCTS 1. FABRICATE AND ERECT ALL DUCTWORK ACCORDING TO ASHRAE AND SMACNA STANDARDS FROM PRIME SHEETS OF NO. 1 GALVANIZED STEEL. COMPLY WITH NFPA 90A REQUIREMENTS. DUCTWORK SHALL BE HOT DIPPED GALVANIZED SHEET STEEL, LOCK FORMING QUALITY, ZINC COATING DESIGNATION G60, ASTM A527. FIBERGLASS DUCTWORK IS PROHIBITED. 2. ALL DUCTWORK SHALL BE FURNISHED, INSTALLED AND FABRICATED IN ACCORDANCE WITH LATEST EDITION OF THE SMACNA LOW PRESSURE AND MEDIUM PRESSURE DUCT CONSTRUCTION STANDARDS MANUALS, DUCTWORK SHALL BE SMACNA LOW PRESSURE CONSTRUCTION 2" STATIC PRESSURE RATING WITH SEAL CLASS A SEAMS AND JOINTS. ALL DUCT SYSTEMS SHALL BE TIGHT AND FREE FROM LEAKS AND VIBRATION, ALL JOINTS IN DUCTWORK SHALL BE SEALED AIRTIGHT. THIS INCLUDES ALL SUPPLY, RETURN, EXHAUST DUCTWORK, AND OUTSIDE AIR DUCTWORK, DUCT SEALER DURODYNE 5-2C SHALL BE USED. 3. INCLUDE ALL TURNING VANES, MANUAL DAMPERS, FLEXIBLE CONNECTORS, GRILLES AND DIFFUSERS, ACOUSTIC LINING, AND OTHER SHEET METAL ACCESSORIES FOR PROJECT. 4. ALL BRANCH CONNECTION FITTINGS IN RECTANGULAR DUCTWORK SHALL BE 45 DEGREE TRANSITION TYPE, CONICAL FITTINGS OR SPIN-IN FITTINGS WITH INTEGRAL AIR SCOOPS. BUTT FITTINGS ARE NOT ACCEPTABLE. USE 45 DEGREE TAKEOFF AT ALL BRANCHES. DO NOT USE SPLITTER DAMPERS OR EXTRACTORS. 5. ALL EXPOSED ROUND DUCTWORK SHALL BE SPIRAL SEAM DUCTWORK. C. SECTION 23 33 00: DUCT ACCESSORIES: 1. FLEXIBLE DUCTWORK IS NOT PERMITTED IN ROOMS WITHOUT CEILINGS. 2. DAMPERS (AS MANUFACTURED BY RUSKIN, NAILOR OR SAFE-AIR) FABRICATE IN ACCORDANCE WITH SMACNA STANDARDS, 18 GAUGE MINIMUM GALVANIZED STEEL. PROVIDE END BEARINGS AND LOCKING, INDICATING QUADRANT REGULATORS. BLADE TO BE SINGLE THICKNESS WITH CONTINUOUS HINGE OR ROD. 3. CONTROL DAMPERS (AS MANUFACTURED BY RUSKIN, NAILOR OR SAFE-AIR) FABRICATE BLADE OF DOUBLE THICKNESS SHEET METAL, OPPOSED BLADE TYPE WITH SELF-ALIGNING ROD AND END BEARING SUITABLE FOR USE WITH AN ACTUATOR. D. SECTION 23 37 13: AIR OUTLETS: DIFFUSERS, GRILLES AND REGISTERS SHALL BE SQUARE OR RECTANGULAR AS MANUFACTURED BY TITUS, SIZE AND CAPACITIES AS SHOWN ON THE DRAWINGS. ALL DIFFUSERS, GRILLES AND REGISTERS SHALL ARE TO HAVE A NOISE CRITERIA LESS THAN 30. SECTION 23 05 93:TESTING, ADJUSTING AND BALANCING A. GENERAL: 1. WORK SHALL INCLUDED ALL LABOR AND SERVICES NECESSARY FOR COMPLETING INSPECTION, TESTING, INITIAL START-UP AND BALANCING OF ALL EQUIPMENT, AIR SYSTEMS OF HVAC WORK AS SHOWN ON DRAWINGS AND SPECIFIED HEREIN. 2. AFTER INSTALLATION, CHECK ALL EQUIPMENT AND PERFORM START UP IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 3. ALL PIPING SHALL BE TESTED AND FREE OF LEAKS AS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. 4. WORK SCHEDULED TO BE CONCEALED OR INSULATED SHALL REMAIN UNCOVERED UNTIL REQUIRED TESTS HAVE BEEN COMPLETED. IF CONSTRUCTION SCHEDULE REQUIRES, ARRANGE FOR TESTS ON SEPARATE SECTIONS OF SYSTEM SEPARATE TIMES. 5. BALANCE ALL SYSTEMS, CALIBRATE CONTROLS, CHECK FOR PROPER OPERATION AND SEQUENCE UNDER ALL CONDITIONS AND MAKE ALL NECESSARY ADJUSTMENTS. 6. INSTRUCT OWNER IN OPERATION OF SYSTEMS AND SUBMIT OPERATING AND MAINTENANCE MANUAL FOR ALL EQUIPMENT AND SYSTEMS. B. BALANCING, START UP AND INSTRUCTIONS: 1. AFTER EQUIPMENT IS PLACED IN OPERATION, SYSTEMS SHALL BE BALANCED TO WITHIN 10% OF DESIGN FLOW WITH REPORT SUBMITTED TO OWNER. BALANCING SHALL BE PERFORMED BY PER AABC OR NEBB. 2. BALANCE THE AIR SYSTEMS PRIOR TO BALANCING HYDRONIC, STEAM, AND REFRIGERANT SYSTEMS. 3. TEST, ADJUST AND BALANCE COOLING SYSTEMS DURING SUMMER SEASON AND HEATING SYSTEMS DURING WINTER SEASON. BALANCE SYSTEMS WHEN THE OUTSIDE AIR CONDITIONS ARE WITHIN 5 DEGREES F WET BULB TEMPERATURE OF THE MAXIMUM SUMMER DESIGN CONDITION AND WITHIN 10 DEGREES F DRY BULB TEMPERATURE OF THE MINIMUM WINTER DESIGN CONDITION. 4. START UP AND PLACE ALL SYSTEMS IN OPERATION AND TAG ALL SWITCHES AND CONTROLS WITH PERMANENT LABELS. 5. INSTRUCT OWNER ON PROPER OPERATION AND PREVENTATIVE MAINTENANCE OF SYSTEM. Mechanical Equipment Schedule Mark Location Type Capacity (CFM) Static Pressure (in.)Voltage Phase Manufacturer Model EF-1 10020 Centrifugal Fan 50 CFM .5 115 1 Greenheck CSP-B110 EF-2 101B Centrifugal Fan 110 CFM .25 115 1 Greenheck PANASONIC FV-11VH2 EF-3 20021 Centrifugal Fan 85 CFM .5 115 1 Greenheck CSP-B110 EF-4 20020 Centrifugal Fan 185 CFM .5 115 1 Greenheck SP-A250 EF-5 30020 Centrifugal Fan 185 CFM .5 115 1 Greenheck SP-A250 WALL HEIGHT DESIGNATIONS F FULL HEIGHT MASONRY, STUDS AND GYPSUM WALL BOARD TO DECK R FULL HEIGHT STUDS. STOP GYPSUM WALL BOARD 6" ABOVE FINISHED CEILING B STUD AND GYPSUM WALL BOARD STOP 6" ABOVE FINISHED CEILING. TOP OF WALL IS DIAGONALLY BRACED AT 48" OC MAX. C STUDS AND GYPSUM WALL BOARD STOP AT CEILING GENERAL NOTES W1 F SYMBOL AND NOMENCLATURE WALL TAG AND HEIGHT DESIGNATIONS WALL TYPE DESIGNATION WALL HEIGHT DESIGNATION WALL CONSTRUCTION DESIGNATIONS G METAL STUD WALL 1.IF NO HEIGHT DESIGNATION IS SHOWN IN THE WALL TAG, THE WALL SHALL BE ASSUMED TO BE FULL HEIGHT F WALL FURRING METAL STUDS W/ BATT INSUL GYPSUM WALL BOARD 5/8" SCHED. AS 5/8" G1 G3 G6 METAL STUDS GYPSUM WALL BOARD 1/2" SCHED. AS 1/2" F2 CORNER REINFORCEMENT SAFB PARTITION TERMINATION SEALANT U.S.G. CONTROL JOINT #093 PROVIDE WALL CONTROL JOINT SPACING PER U.S.G. HANDBOOK WALL PLAN SECTIONS METAL STUD SEALANTPERIMETER RELIEF AT WALL INTERSECTION METAL TRIM PARTITION CORNER JOINT RELIEF CORNER RELIEF METAL STUD SOUND -ISOLATING PARTITION INTERSECTION JOINT RELIEF METAL STUD DRYWALL SCREW WALL/ FLOOR INTERSECTIONS AT ELECTRICAL BOXES 3" SAFB INSUL METAL STUD RUNNER ACOUSTIC SEALANT ACOUSTIC SEALANT * REFER TO PARTITION SCHEDULE FOR GWB LAYERS AND THICKNESSES. (3) THREE BEADS ACOUSTICAL SEALANT @ TRACK 3" SOUND ATTENUATION BATTS. ACOUSTICAL PUTTY PADS, 3M FIRE BARRIER PADS, OR EQUAL AT ALL ELECTRIC OUTLETS IN PARTITIONS: CLASSROOM/ CLASSROOM; CLASSROOM/ CORRIDORS; CLASSROOM/ STAIRWELLS.6" MAX2" MIN6" MAX2" MINBeardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. ©Filename:Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE no. revision description by date 4/13/2020 11:12:53 AMC:\Projects\BEAR-A-19100-V2018_nhavrish.rvtARCHITECTURE Cornell UniversityA-001 04.15.2020 WALL SCHEDULEZeta Psi Bathroom Renovations534 Thurston Avenue Ithaca, NY 14850NRH 19100 MAR NRH 2020 SCALE:1" = 1'-0" WALL TYPE LEGEND WALL AND PARTITION SCHEDULE MARK THICKNESS DESCRIPTION WALL ACCESSORIES EXECUTION RATING (MIN)FIRE TEST NO.STCACOUSTIC CAULKSOUND ATTENUATIONSOUND TEST #COMMENTS METAL STUD FRAMING ASSEMBLIES F2 3 1/2" 2 1/2" METAL STUD FRAMING WITH (1) LAYERS OF 1/2" GWB EACH SIDE. NONE INSTALL STUD FRAMING AT 24" OC MAX. INSTALL GWB HORIZONTALLY OR VERTICALLY. VERTICAL JOINTS SHALL BE CENTERED OVER STUDS AND STAGGERED ONE STUD CAVITY ON OPPOSITE SIDES OF STUDS. -- -- -- G1 2 7/8" 1 5/8" METAL STUD FRAMING WITH (1) LAYER OF 5/8" TYPE 'C' GWB EACH SIDE. NONE INSTALL STUD FRAMING AT 24" OC MAX. INSTALL GWB HORIZONTALLY OR VERTICALLY. VERTICAL JOINTS SHALL BE CENTERED OVER STUDS AND STAGGERED ONE STUD CAVITY ON OPPOSITE SIDES OF STUDS. 60 U419 38 Yes Yes USG-860809 SEAL TO DECK ABOVE TO MAINTAIN REQUIRED RATING. G3 4 7/8" 3 5/8" METAL STUD FRAMING WITH (1) LAYER OF 5/8" TYPE 'X' GWB EACH SIDE. NONE INSTALL STUD FRAMING AT 24" OC MAX. INSTALL GWB HORIZONTALLY OR VERTICALLY. VERTICAL JOINTS SHALL BE CENTERED OVER STUDS AND STAGGERED ONE STUD CAVITY ON OPPOSITE SIDES OF STUDS. 60 U419 -- SEAL TO DECK ABOVE TO MAINTAIN REQUIRED RATING. G6 7 1/4" 6" METAL STUD FRAMING WITH (1) LAYER OF 5/8" GWB EACH SIDE NONE INSTALL STUD FRAMING AT 24" OC MAX. INSTALL GWB HORIZONTALLY OR VERTICALLY. VERTICAL JOINTS SHALL BE CENTERED OVER STUDS AND STAGGERED ONE STUD CAVITY ON OPPOSITE SIDES OF STUDS. -- -- -- WALL FURRING F1 5/8" 5/8" GWB SHEET ADHERED DIRECTLY TO SUBSTRATE NONE SECURE GWB DIRECTLY TO SUBSTRATE WITH CONSTRUCTION ADHESIVE -- -- -- F1B 1/2" 5/8" GWB SHEET ADHERED DIRECTLY TO SUBSTRATE NONE SECURE GWB DIRECTLY TO SUBSTRATE WITH CONSTRUCTION ADHESIVE -- -- -- F5 3 1/8" 2 1/2" METAL STUD FRAMING WITH (1) LAYER OF 5/8" GWB AT ROOM SIDE. MINERAL WOOL BATT INSULATION (SEE COMMENTS) INSTALL METAL STUDS AT 16" OC (VERTICAL ORIENTATION). INSTALL GWB HORIZONTALLY WITH STAGGERED JOINTS. -- -- -- F5B 3" 2 1/2" METAL STUD FRAMING WITH (1) LAYER OF 5/8" GWB AT ROOM SIDE. MINERAL WOOL BATT INSULATION (SEE COMMENTS) INSTALL METAL STUDS AT 16" OC (VERTICAL ORIENTATION). INSTALL GWB HORIZONTALLY WITH STAGGERED JOINTS. -- -- -- F6 4 1/4" 3 5/8" METAL STUD FRAMING WITH (1) LAYER OF 5/8" GWB AT ROOM SIDE. MINERAL WOOL BATT INSULATION (SEE COMMENTS) INSTALL METAL STUDS AT 16" OC (VERTICAL ORIENTATION). INSTALL GWB HORIZONTALLY WITH STAGGERED JOINTS. -- -- -- METAL STUD AND FURRING WALL TYPE NOTES 1 SEE GENERAL PARTITION NOTES FOR ADDITIONAL NOTES. 2 SEE ROOM FINISH SCHEDULES FOR WALL BASE AND FINISHES 3 SEE PLANS AND WALL TYPE SCHEDULE FOR TYPE DESIGNATIONS AND THICKNESSES 4 WHERE FURRING IS NOT REQUIRED TO BE FULL HEIGHT, EXTEND TOP OF FURRING/ GWB 6" MIN ABOVE FINISHED CEILING. CONTINUE FURRING/ GWB TO UNDERSIDE OF FLOOR/ ROOF DECK WHERE NO CEILING OCCURS OR WHERE FINISHED WALL SURFACE WILL BE VISIBLE. 5 AT ALL OPENINGS, INCLUDING BUT NOT LIMITED TO, DOORS, WINDOWS, RECESSES, ETC., RETURN GWB ONLY AT JAMBS AND HEAD OF OPENING TO FACE OF FRAMES. TERMINATE GWB WITH APPROPRIATE TRIM AND CAULK RESULTING JOINT BETWEEN TRIM AND FACE OF FRAME UNLESS OTHERWISE NOTED OR INDICATED IN DRAWINGS. SCALE:3" = 1'-0"1 TYPICAL PARTITION DETAILS GENERAL PARTITION NOTES A ALL GYPSUM WALL BOARD TO BE TYPE 'X' UNLESS OTHERWISE NOTED B ALL PARTITIONS ARE TO EXTEND TO THE UNDERSIDE OF DECK/STRUCTURE ABOVE UNLESS INDICATED OTHERWISE C PROVIDE CONTROL JOINTS IN GYPSUM WALL BOARD WALL & CEILINGS. CONTROL JOINTS SHALL BE INSTALLED IN CEILINGS EXCEEDING 30 L.F. PROVIDE JOINT WHERE CEILING FRAMING OR FURRING CHANGES DIRECTION AND WHERE CONTROL JOINTS OCCUR IN EXTERIOR WALL D FOR STUD CONSTRUCTION NOT EXTENDING TO THE STRUCTURE, PROVIDE DIAGONAL BRACING FROM TOP OF WALL TO STRUCTURE ABOVE. INSTALL AT 48" O.C. MAX SPACING AND AT EACH DOOR JAMB E MOISTURE RESISTANT GYPSUM BOARD TO BE USED IN ALL TOILET AND BATHROOMS. SUBSTITUTE CEMENT BACKING BOARD FOR GYPSUM BOARD DIRECTLY BEHIND ALL WALLS/SURFACES TO RECEIVE CERAMIC OR PORCELAIN TILE, STONE OR EPOXY F PROVIDE CONTROL JOINTS FOR FINISHES (TILE OR GYPSUM BOARD) THAT BRIDGE EXISTING CONTROL JOINTS / EXPANSION JOINTS G ALL GYPSUM WALL BOARD EXPOSED TO VIEW OR INDICATED TO RECEIVE PAINT OR EPOXY FINISH SHALL HAVE A LEVEL 4 FINISH. GYPSUM WALL BOARD OBSCURED FROM VIEW SHALL HAVE A LEVEL 2 FINISH. 2 3PROVIDE TRANSLUCENT FILM AT EXISTING WINDOWS (TYP OF TWO) 12 A-430 WC-1 SH-1 LAV-1 WC-2 LAV-2 HB-1 A-430 13 MR (24X36) TTD SND TTD SND FD-1 FD-1 RH(x2) AND SHELF 1'-5" EQ EQ 10041101A 101 37 SF GUEST RESTROOM 101B 43 SF ACCESSIBLE UNISEX RESTROOM 10020 EHDP.1 P.3 P.3 P.3 P.5P.5 EXISTING 4" SAN UP AND DN EXISTING DOMESTIC WATER RISERS P-101 1 P-101 2 PROVIDE 2" V ABOVE 2" V UP PROVIDE 6" EXHAUST ABOVE 6" EXH UP TO ATTIC A-430 5 4 P.3 VGB GB GB EF-2 PROVIDE 6" EXHAUST ABOVE WW EXISTING 1" 1" 1" SP.2 SP.1 DE.6 143.00°O.1 G6 G3 F5 G1 F6 MR(24X60) 12" AFF DTL 6/A-4302'-2 3/4"1'-3"MAIN ENTRANCE - EXISTING TO REMAIN - ACCESSIBLE 8" MAIN LOBBY (FIRST FLOOR MATCHES THIS LEVEL)TYP BOTH SIDES OF DOOR - EXTEND/SEAL TO DECK P.6 CODE ISSUE: OCCUPANCY CLASSIFICATION MAXIMUM BUILDING OCCUPANCY FIRE AREA CALCUALTIONS - SPRINKLER SYSTEM COMMENTS: 20,200 SF 46 R-2 DESCRIPTION: BASED ON PREVIOUSLY CALCULATED OCCUPANCY FOR ROOM OCCUPANCY AND THE COMMERCIAL KITCHEN OCCUPANCY. EXISTING BUILDING INCLUDES AN EXISTING SPRINKLER SYSTEM TO REMAIN. C O D E S U M M A R Y - ZETA PSI FRATERNITY HOUSE THE ALLOWABLE FIRE AREA FOR A RESIDENTIAL (FRATERNITY) BUILDING IS 20,000 SF. THE EXISTING FIRE AREA IS 20,200 SF THUS DOES NOT COMPLY WITH THE BUILDING CODE OF NEW YORK STATE. NO MODIFICATIONS TO THE EXISTING NON-CONFORMING FIRE AREA ARE PLANNED FOR THIS PROJECT. RESIDENTIAL: FRATERNITIES & SORORITIES Y EXISTING THE FOLLOWING CODE SUMMARY WAS REFERENCED WITH USE OF THE: 1. 2015 INTERNATIONAL BUILDING CODE 2. 2017 NEW YORK STATE UNIFORM CODE SUPPLEMENT (MARCH 2017) 3. 2016 CODE & COMMENTARY TO THE ENERGY CONSERVATION CONSTRUCTION CODE 4. ICC/ANSI A117.1-2003 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 5. 2015 INTERNATIONAL EXISTING BUILDING CODE CONSTRUCTION TYPE (EXISTING) *ASSUMED PER ORIGINAL DRAWINGS IIIB EXTERIOR WALL CONSTRUCTION: BRICK/MASONRY INTERIOR CONSTRUCTION: MASONRY, CONCRETE, PLASTER, AND WOOD FRAMING PLUMBING FIXTURES REQUIREMENTS - ZETA PSI FRATERNITY HOUSE (R-2 FRATERNITY) WATER CLOSETS: MALE FEMALE LAVATORIES: MALE FEMALE BATHTUBS OR SHOWERS DRINKING FOUNTAINS OTHER REQUIRED PROVIDED COMMENTS 5 (1 PER 10) 5 (1 PER 10) 6 (1 PER 8) (1 PER 100)UNKNOWN NOT IN SCOPE (1 SERVICE SINK)1 7 7 (INC. 1 ADA UNISEX AND 1 URINAL) 10 (INC. 1 ADA UNISEX) LOCATED IN BASEMENT PROJECT IS CLASSIFIED AS ALTERATIONS -LEVEL 2 PER 2015 INTERNATIONAL EXISTING BUILDING CODE. EXISTING OCCUPANT LOAD AND MEANS OF EGRESS SHALL NOT BE IMPACTED BY THE WORK. 12 A-430 ENTRY 10041 101 101A DP.2 DP.2 DP.1 EXISTING 4" SAN UP AND DN EXISTING DOMESTIC WATER RISERS DO.1 DO.1 DW.2 DW.2 SO ±10SF ±10SF -MAINTAIN EXISTING FIRE ALARM PANEL CONDUIT AND SPRINKLER PIPING IN EXISTING LOCATIONS AND PROVIDE TEMPORARY SUPPORT / PROTECTION AS REQUIRED DC.2 DC.2 DO.1 DW.2 DE.6 DE.3 DE.4 DF.1 DW.5 DC.1 DC.3 FIRE SUPPRESSION SYMBOLS SYMBOL DESCRIPTION REMOVE TO POINT FOR RECONNECTION PIPE RISE PIPE DROP POINT OF CONNECTION (CONNECT TO EXISTING) WET PIPE SYSTEM PIPING (EXISTING)W RESIDENTIAL SIDEWALL SPRINKLER WET PIPE SYSTEM PIPING (NEW)W Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. ©Filename:Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE no. revision description by date 4/13/2020 11:12:54 AMC:\Projects\BEAR-A-19100-V2018_nhavrish.rvtARCHITECTURE Cornell UniversityA-101 04.15.2020 FIRST FLOOR PLANZeta Psi Bathroom Renovations534 Thurston Avenue Ithaca, NY 14850NRH/DJW 19100 MAR NRH 2020 PLAN NORTH0'2'1'4'6' SCALE : 1/2" = 1'-0" SCALE:1/2" = 1'-0"2 FIRST FLOOR PLAN - ALTERNATE 1 Dx = DEMOLITION KEYNOTE P = PLUMBING E = EQUIPMENT KEYED NOTES LOCATED WITHIN A SPACE SHALL APPLY THROUGHOUT THE SPACE UNLESS OTHERWISE INDICATED. KEYED NOTES DC.1 REMOVE SUSPENDED/APC CEILING COMPLETE. TAKE ALL NECESSARY PRECAUTIONS TO PROTECT EXISTING SPRINKLER HEADS. DC.2 SELECTIVE REMOVAL OF GYPSUM / PLASTER CEILING TO ACCOMMODATE INSTALLATION OF NEW PLUMBING ABOVE, TAKE ALL NECESSARY PRECAUTIONS TO PROTECT EXISTING SPRINKLER HEADS. DC.3 REMOVE ABANDONED EQUIPMENT, FIXTURES, CONDUITS, JUNCTION BOXES, PIPING, ETC ABOVE EXISTING SUSPENDED CEILING DE.3 REMOVE ALL TOILET ACCESSORIES, COMPLETE, INCLUDING, BUT NOT LIMITED TO, MIRRORS, GRAB BARS, TOILET SEAT COVER DISPENSERS, TOILET TISSUE DISPENSER, PAPER TOWEL DISPENSERS, ELECTRIC HAND DRYERS, SHOWER CURTAINS, ROBE HOOKS, ETC...AND TURN OVER TO OWNER DE.4 REMOVE LIGHT FIXTURES, WALL OUTLETS, SWITCHES, CONDUIT, RACEWAY, ETC. TO PROVIDE NEW FINISH THROUGHOUT SPACE. SALVAGE OUTLETS, SWITCHES, BOXES, AND CONDUIT FOR REUSE IN SAME LOCATION. REINSTALL IN SAME LOCATION AND RECESS WIRING IN NEW FURRING AS INDICATED IN PLANS. REMOVE FIRE ALARM EQUIPMENT AND SALVAGE FOR REINSTALLATION IN SAME LOCATION. SELECTIVELY REMOVE CEILING FINISH TO PROVIDE RECESSED WIRING TO NEW LIGHT FIXTURES AND REINSTALLED FIRE ALARM EQUIPMENT. DE.6 MOVE PANEL AND ASSOCIATED WIRING TO COORDINATE WITH WALL REMOVAL AND RECONSTRUCTION TO LOCATE PANEL APPROXIMATELY 1'-0" NORTH OF EXISTING LOCATION. PROVIDE NEW SURFACE RACEWAY AS REQUIRED. PROVIDE OWNER, FIRE DEPARTMENT, AND CAMPUS EH&S WITH TWO DAYS MINIMUM NOTICE OF DISCONNECT AND MINIMIZE PANEL DOWN TIME. DF.1 REMOVE TILE FLOOR COMPLETE TO SUBSTRATE DO.1 REMOVE DOOR, FRAME AND HARDWARE, COMPLETE. DP.1 REMOVE FIXTURE AND TRIM. EXISTING ROUGH-IN PIPING WILL REMAIN FOR CONNECTION TO NEW FIXTURE. DP.2 REMOVE FIXTURE, TRIM AND ASSOCIATED PIPING. CAP PIPING BELOW FLOOR AND BEHIND WALL. WHERE WALL IS TO BE REMOVED, TERMINATE AND CAP PIPING TO NEAREST LOCATION CONCEALED FROM VIEW OR AT NEAREST MAIN IN BASEMENT. DW.2 REMOVE WALL CONSTRUCTION AS INDICATED. COORDINATE EXTENT WITH RECONSTRUCTION PLAN. AT LOCATIONS OF NEW LAVATORIES PROVIDE SELECTIVE WALL DEMOLITION TO FOR INSTALLATION OF NEW VENT AND SUPPLY PIPING DW.5 REMOVE CERAMIC TILE WAINSCOT, COMPLETE (± 60" AFF) O.1 3-0 X 7-0 FLUSH WOOD DOOR WITH 18GA HOLLOW METAL FRAME (45 MINUTE FIRE AND SMOKE RATED). HARDWARE GROUP #1. STAIN FINISH AT DOOR AND PAINTED FRAME TO MATCH EXISTING. P.1 PROVIDE FIXTURE AND TRIM. CONNECT TO EXISTING ROUGH-IN PIPING. P.3 PROVIDE FIXTURE, TRIM AND ASSOCIATED PIPING. PROVIDE DOMESTIC WATER, SANITARY WASTE AND VENT ROUGH-IN PIPING AND CONNECT TO EXISTING RESPECTIVE SYSTEMS. P.5 PROVIDE FLOOR DRAIN AND TRAP. PROVIDE ROUGH-IN PIPING AND CONNECT TO EXISTING WASTE PIPING. PROVIDE TRAP PRIMER VALVE AND TRAP PRIMER LINE. P.6 PROVIDE HOSE BIBB. PROVIDE ROUGH-IN PIPING AND CONNECT TO EXISTING DOMESTIC HOT AND COLD WATER PIPING. SO SALVAGE TO OWNER SP.1 REMOVE EXISTING SIDEWALL SPRINKLER AND PIPING TO POINT INDICATED. PROVIDE NEW 1" PIPING AND SIDEWALL SPRINKLER LOCATED PERPENDICULAR TO NEW WALL ANGLE. SP.2 REMOVE EXISTING PENDENT SPRINKLER AND REDUCING COUPLING. CONNECT TO 1" DROP PIPE AND RUN NEW EXPOSED 1" PIPE TIGHT TO EXISTING CEILING AND PROVIDE SIDEWALL SPRINKLER. PATCH AND PAINT CEILING AT EXISTING PENDENT SPRINKLER LOCATION. SCALE:1/2" = 1'-0"1 FIRST FLOOR DEMOLITION PLAN - ALTERNATE 1 FIRE SUPPRESSION GENERAL NOTES A PROVIDE MODIFICATIONS TO AN EXISTING WET PIPE TYPE FIRE SPRINKLER SYSTEM. COORDINATE WITH EH&S AND ITHACA FIRE DEPARTMENT PRIOR TO SHUT DOWN AND DRAIN OF EXISTING SPRINKLER SYSTEM ZONE SERVING FIRST FLOOR TOILET ROOMS AREA. B COORDINATE AND PERFORM WORK IN A MANNER WHICH MINIMIZES SPRINKLER SYSTEM IMPAIRMENT IN THE AREAS, DEVELOP PLAN INDICATING EXTENT AND EXPECTED DURATION OF SYSTEM IMPAIRMENT AND REVIEW WITH EH&S AND ITHACA FIRE DEPARTMENT. C PIPING AS SHOWN OR INDICATED IS DIAGRAMMATIC, SUBCONTRACTOR IS RESPONSIBLE FOR FINAL SPRINKLER SYSTEM PIPE LAYOUT AND COORDINATION WITH ALL EXISTING CONDITIONS AND OTHER TRADES. D REMOVE EXISTING WET PIPE SYSTEM BRANCH LINE, PIPING, FITTINGS, SPRINKLERS, AND ASSOCIATED HANGERS INDICATED. E PROVIDE CONNECTION TO EXISTING WET PIPE SYSTEM AT BRANCH LINES. PROVIDE ALL PIPING FITTINGS, HANGERS AND SPRINKLERS REQUIRED TO MAKE ALTERATIONS INDICATED AND INSTALL IN ACCORDANCE WITH REQUIREMENTS OF NFPA 13 AND SPECIFICATIONS. REMOVE EXISTING CURB AND FRAMED OPENING -FINISH FLUSH WITH RAISED SHOWER LEVEL AND ADJACENT FINISHES 205 CORRIDOR 20041 STAIR 20003 DP.1 DP.1 DP.1 DP.1 DP.1 DP.1 DP.1 DP.1 DP.1 DP.1 DP.3 EXISTING 4" SAN DN EXISTING SAN EXISTING DOMESTIC WATER RISERS EXISTING 3/4" H&C EXISTING 4" VENT DN EXISTING 4" VENT UP TOILET / SHOWER ROOM 20020 CORRIDOR 20041 DW.2 DW.5 DW.4 DW.5 DE.1 DE.3 DE.3 DE.4 DC.2 DME.1 ABOVE SO DE.5 2 3 LAV-4 WC-1 WC-1 UR-1 FD-1 HB-1 SH-2 SH-2 SH-2 EX FD TTD TTD RH (x3) MR (108X36) TOILET / SHOWER ROOM 20020 20003 20041 205 EHD P.1 P.1 P.1 P.1 P.6 P.5 P.2 P.1 P.1 P.1 P.4 P.1 P.1 PROVIDE TRAP PRIMER VALVE EXISTING 4" SAN DN EXISTING DOMESTIC WATER RISERS EXISTING 3/4" H&C EXISTING 4" VENT DN EXISTING 4" VENT UP EX 4" SAN PROVIDE 2" VENT P-102 1 P-102 2 CORRIDOR 20041 A-430 7 E.5 ABOVE EF-4 E.10 O.2 F1 2 LAYERS F1 2 LAYERS F1 F1 9 8 USCRN USCRN EQEQ2'-6"TPTN TPTN SHELF SHELF SSM-2 AT THIS WALL ELEVATION CT-1 CT-1 PFT-1PFT-1 CT-2 (ABOVE AND BELOW SINKS) DP.1 DP.1 DP.4 REMOVE ±5 SF CEILING AT FIRST FLOOR BELOW TO ACCOMMODATE NEW SHOWER DRAIN AND 2" PIPING DE.3 DE.4 DF.1 DE.2 DE.2 DME.1 GRILLE ABOVE DW.5 DW.2 3 A-701 WC-1 LAV-2 MR WITH LIGHT BASIS OF DESIGN:BASCO INFINITY SEMI-FRAMELESS 1/4" TEMPERED GLASS SLIDING WITH INLINE PANEL SHOWER DOOR -70" HIGH PRESIDENTS RESTROOM 20021 213 P.1 P.1 P.3 SH-3 P-101 3 P-101 4 F5B E.1 E.2 E.5 F.1 F.2 ABOVE TTD A-430 3 1 2W.1 3 A-701 F1B TYP THIS ROOM SHELF SHELF & RH (x2) Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. ©Filename:Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE no. revision description by date 4/13/2020 11:12:56 AMC:\Projects\BEAR-A-19100-V2018_nhavrish.rvtARCHITECTURE Cornell UniversityA-102 04.15.2020 SECOND FLOOR PLANSZeta Psi Bathroom Renovations534 Thurston Avenue Ithaca, NY 14850NRH/DJW 19100 MAR NRH 2020 PLAN NORTH0'2'1'4'6' SCALE : 1/2" = 1'-0" SCALE:1/2" = 1'-0"1 SECOND FLOOR PLAN - DEMOLITION SCALE:1/2" = 1'-0"2 SECOND FLOOR PLAN SCALE:1/2" = 1'-0"3 PRESIDENT'S SUITE DEMO - ALTERNATE 2 SCALE:1/2" = 1'-0"4 PRESIDENT'S SUITE RESTROOM - ALTERNATE 2 Dx = DEMOLITION KEYNOTE P = PLUMBING E = EQUIPMENT KEYED NOTES LOCATED WITHIN A SPACE SHALL APPLY THROUGHOUT THE SPACE UNLESS OTHERWISE INDICATED. KEYED NOTES DC.2 SELECTIVE REMOVAL OF GYPSUM / PLASTER CEILING TO ACCOMMODATE INSTALLATION OF NEW PLUMBING ABOVE, TAKE ALL NECESSARY PRECAUTIONS TO PROTECT EXISTING SPRINKLER HEADS. DE.1 REMOVE TOILET PARTITIONS AND ACCESSORIES COMPLETE. DE.2 REMOVE MISCELLANEOUS EQUIPMENT, FIXTURES AND ACCESSORIES COMPLETE. DE.3 REMOVE ALL TOILET ACCESSORIES, COMPLETE, INCLUDING, BUT NOT LIMITED TO, MIRRORS, GRAB BARS, TOILET SEAT COVER DISPENSERS, TOILET TISSUE DISPENSER, PAPER TOWEL DISPENSERS, ELECTRIC HAND DRYERS, SHOWER CURTAINS, ROBE HOOKS, ETC...AND TURN OVER TO OWNER DE.4 REMOVE LIGHT FIXTURES, WALL OUTLETS, SWITCHES, CONDUIT, RACEWAY, ETC. TO PROVIDE NEW FINISH THROUGHOUT SPACE. SALVAGE OUTLETS, SWITCHES, BOXES, AND CONDUIT FOR REUSE IN SAME LOCATION. REINSTALL IN SAME LOCATION AND RECESS WIRING IN NEW FURRING AS INDICATED IN PLANS. REMOVE FIRE ALARM EQUIPMENT AND SALVAGE FOR REINSTALLATION IN SAME LOCATION. SELECTIVELY REMOVE CEILING FINISH TO PROVIDE RECESSED WIRING TO NEW LIGHT FIXTURES AND REINSTALLED FIRE ALARM EQUIPMENT. DE.5 REMOVE RADIATOR AND SALVAGE TO OWNER FOR REFINISHING. PROVIDE ALL NECESSARY ACCESSORIES, PIPING, FITTINGS, AND PIPE WRAP TO REINSTALL FOLLOWING REFINISHING BY OWNER. DF.1 REMOVE TILE FLOOR COMPLETE TO SUBSTRATE DME.1 REMOVE EXHAUST FAN, INCLUDING BUT NOT LIMITED TO, GRILLE, FAN, MOUNTING HARDWARE AND ACCESSORIES. DISCONNECT EXISTING FAN FROM BRANCH CIRCUIT. DP.1 REMOVE FIXTURE AND TRIM. EXISTING ROUGH-IN PIPING WILL REMAIN FOR CONNECTION TO NEW FIXTURE. DP.3 EXISTING FLOOR DRAIN BODY WILL REMAIN. REMOVE FLOOR DRAIN STRAINER AND VERIFY SIZE , MAKE AND MODEL OF EXISTING STRAINER HEAD. DP.4 REMOVE FIXTURE AND TRIM. REMOVE 1 1/2" DRAINAGE PIPING. EXISTING DOMESTIC WATER PIPING WILL REMAIN FOR CONNECTION TO NEW SHOWER FIXTURE. DW.2 REMOVE WALL CONSTRUCTION AS INDICATED. COORDINATE EXTENT WITH RECONSTRUCTION PLAN. AT LOCATIONS OF NEW LAVATORIES PROVIDE SELECTIVE WALL DEMOLITION TO FOR INSTALLATION OF NEW VENT AND SUPPLY PIPING DW.4 REMOVE SOLID SURFACE WALL PANELS THROUGHOUT, COMPLETE. PREPARE RESULTING SURFACE TO ACCEPT NEW FINISH. DW.5 REMOVE CERAMIC TILE WAINSCOT, COMPLETE (± 60" AFF) E.1 PROVIDE COUNTER, CASEWORK WHERE APPLICABLE, AND ACCESSORIES AS DETAILED. COORDINATE WITH INTERIOR ELEVATIONS AND DETAILS. E.2 PROVIDE TOILET ACCESSORIES AS INDICATED/ SPECIFIED. COORDINATE REQUIREMENTS WITH FIXTURE ACCESSORY MOUNTING HEIGHT SCHEDULE E.5 CONTRACTOR TO FIELD VERIFY IF ANY ADDITIONAL MECHANICAL FANS EXIST AT THIS LOCATION OR AT ROOF OUTLET FOLLOWING SELECTIVE DEMOLITION. ADVISE ARCHITECT OF EXISTING CONDITION AND PROVIDE NEW EXHAUST FAN. MODIFY WALL OPENING AS REQUIRED TO ACCOMMODATE NEW GRILLE/FAN. PROVIDE NEW DUCTWORK, TRANSITIONS, AND FITTINGS TO CONNECT TO EXISTING DUCTWORK AND PROVIDE CONNECTION TO EXISTING ELECTRICAL BRANCH CIRCUITING. E.10 PROVIDE COVERPLATE OVER JUNCTION BOX IN UTILITY BOX LOCATED IN WALL. F.1 PROVIDE CERAMIC/PORCELAIN TILE AND ACCESSORIES. PROVIDE SHEET APPLIED, BONDED WATERPROOF MEMBRANE AND ACCESSORIES AT ALL TILE LOCATIONS THROUGHOUT (BASIS OF DESIGN: SCHLUTER KERDI OR EQUAL). F.2 PROVIDE SURFACE PREPARATION AS REQUIRED TO PROVIDE SCHEDULED FINISH THROUGHOUT THIS SPACE AND ALL ANCILLARY SPACES AS INDICATED ON THE ROOM FINISH SCHEDULE O.2 REMOVE SIGNAGE FROM DOOR LEAF, REFINISH AND STAIN EXISTING DOOR PANEL. REPAINT EXISTING FRAMES. REPAIR AND/OR RESTORE EXISTING HARDWARE AS REQUIRED TO PROVIDE FULL FUNCTIONALITY. PROVIDE NEW MOP PLATE (FINISH TO MATCH EXISTING HARDWARE) ON INTERIOR SIDE OF DOOR PANEL. PROVIDE NEW "RESTROOM" SIGNAGE AT CORRIDOR PER SIGNAGE DETAILS. P.1 PROVIDE FIXTURE AND TRIM. CONNECT TO EXISTING ROUGH-IN PIPING. P.2 PROVIDE FIXTURE, FIXTURE SUPPORT AND TRIM. CONNECT TO EXISTING ROUGH-IN PIPING. P.3 PROVIDE FIXTURE, TRIM AND ASSOCIATED PIPING. PROVIDE DOMESTIC WATER, SANITARY WASTE AND VENT ROUGH-IN PIPING AND CONNECT TO EXISTING RESPECTIVE SYSTEMS. P.4 PROVIDE FLOOR DRAIN STRAINER AND CONNECT TO EXISTING FLOOR DRAIN BODY. INSTALL STRAINER FLUSH WITH FINISHED FLOOR. P.5 PROVIDE FLOOR DRAIN AND TRAP. PROVIDE ROUGH-IN PIPING AND CONNECT TO EXISTING WASTE PIPING. PROVIDE TRAP PRIMER VALVE AND TRAP PRIMER LINE. P.6 PROVIDE HOSE BIBB. PROVIDE ROUGH-IN PIPING AND CONNECT TO EXISTING DOMESTIC HOT AND COLD WATER PIPING. SO SALVAGE TO OWNER W.1 PROVIDE CEMENT BOARD THROUGHOUT THIS SPACE AND TERMINATE AT CEILING HEIGHT. PREPARE TO RECEIVE NEW FINISH REMOVE EXISTING CURB AND FRAMED OPENING -FINISH FLUSH WITH RAISED SHOWER LEVEL AND ADJACENT FINISHES STAIR 3005 3006 CORRIDOR 30040 DP.1 DP.1 DP.1 DP.1 DP.1 DP.1 DP.1 DP.3 EXISTING 3/4" H&C EXISTING 4" VENT UP EXISTING 4" VENT DN 2 3 LAV-3 WC-1 WC-1 FD-1 HB-1 SH-2 SH-2 EX FD CMT ACCENT WALL ABOVE SOLID SURFACE SHELF TTD TTD RH (x3) MR (72X36) STAIR 3005 3006 CORRIDOR 30040 TOILET / SHOWER ROOM 30020 EHD P.1 P.1 P.1 P.6 P.5 P.1 P.1 P.4 P.1 P.1 EXISTING 3/4" H&C EXISTING 4" VENT UP EXISTING 4" VENT DN P-102 1 P-102 2 PROVIDE TRAP PRIMER VALVE EF-5 O.2 A-43010 11 SHELF CT-1 CT-1 PFT-1PFT-1 CT-2 (ABOVE AND BELOW SINKS) SSM-2 AT THIS WALL ELEVATION Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. ©Filename:Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE no. revision description by date 4/13/2020 11:12:57 AMC:\Projects\BEAR-A-19100-V2018_nhavrish.rvtARCHITECTURE Cornell UniversityA-103 04.15.2020 THIRD FLOOR PLANZeta Psi Bathroom Renovations534 Thurston Avenue Ithaca, NY 14850NRH/DJW 19100 MAR NRH 2020 PLAN NORTH0'2'1'4'6' SCALE : 1/2" = 1'-0" SCALE:1/2" = 1'-0"1 THIRD FLOOR PLAN DEMOLITION SCALE:1/2" = 1'-0"2 THIRD FLOOR PLAN Dx = DEMOLITION KEYNOTE P = PLUMBING E = EQUIPMENT KEYED NOTES LOCATED WITHIN A SPACE SHALL APPLY THROUGHOUT THE SPACE UNLESS OTHERWISE INDICATED. KEYED NOTES DP.1 REMOVE FIXTURE AND TRIM. EXISTING ROUGH-IN PIPING WILL REMAIN FOR CONNECTION TO NEW FIXTURE. DP.3 EXISTING FLOOR DRAIN BODY WILL REMAIN. REMOVE FLOOR DRAIN STRAINER AND VERIFY SIZE , MAKE AND MODEL OF EXISTING STRAINER HEAD. O.2 REMOVE SIGNAGE FROM DOOR LEAF, REFINISH AND STAIN EXISTING DOOR PANEL. REPAINT EXISTING FRAMES. REPAIR AND/OR RESTORE EXISTING HARDWARE AS REQUIRED TO PROVIDE FULL FUNCTIONALITY. PROVIDE NEW MOP PLATE (FINISH TO MATCH EXISTING HARDWARE) ON INTERIOR SIDE OF DOOR PANEL. PROVIDE NEW "RESTROOM" SIGNAGE AT CORRIDOR PER SIGNAGE DETAILS. P.1 PROVIDE FIXTURE AND TRIM. CONNECT TO EXISTING ROUGH-IN PIPING. P.4 PROVIDE FLOOR DRAIN STRAINER AND CONNECT TO EXISTING FLOOR DRAIN BODY. INSTALL STRAINER FLUSH WITH FINISHED FLOOR. P.5 PROVIDE FLOOR DRAIN AND TRAP. PROVIDE ROUGH-IN PIPING AND CONNECT TO EXISTING WASTE PIPING. PROVIDE TRAP PRIMER VALVE AND TRAP PRIMER LINE. P.6 PROVIDE HOSE BIBB. PROVIDE ROUGH-IN PIPING AND CONNECT TO EXISTING DOMESTIC HOT AND COLD WATER PIPING. OS3 OS3 OS3 OS3 OS3 OS3 EF-1 GFCI GFCIHD FABOVE COUNTER HEIGHT M M BB B 9'-8"1 7'-2"2 PNT EXISTF M EHD E.8 EF EF AE.7 EXISTING SLOPED CEILING 8'-4"2 PNT EXIST GFCI M M EHDEF GFCI REMOVE WALL CONSTRUCTION TO PROVIDE SOFFIT MATCHING HEIGHT OF LOW POINT OF EXISTING ANGLED CEILING - GWB FINISH AND PAINT HD FEXISTING TO REMAIN FPROVIDE FIRE ALARM VISUAL DEVICE -CONNECT TO EXISTING VISUAL ALARM CIRCUIT REPLACE EXISTING ACCESS PANEL WITH HIDDEN FLUSH DRYWALL INLAY ACCESS PANEL TO RECEIVE WALL FINISH -MATCH EXISTING SIZE (BASIS OF DESIGN -BEST ACCESS DOORS) EXISTING EXHAUST FAN TO REMAIN -CLEAN AND REPAIR TO RESTORE FULL FUNCTIONAILITY A A B B B abA a C b 7'-11"2 PNT EXIST GFCI M EF E.9 FHD 8'-11"2 PNT EXIST GFCI M M EHD EF HD FEXISTING TO REMAIN REPLACE EXISTING ACCESS PANEL WITH HIDDEN FLUSH DRYWALL INLAY ACCESS PANEL TO RECEIVE WALL FINISH -MATCH EXISTING SIZE (BASIS OF DESIGN -BEST ACCESS DOORS) EXISTING EXHAUST FAN TO REMAIN -CLEAN AND REPAIR TO RESTORE FULL FUNCTIONAILITY DE.5 A A B B 0 T LIGHTING SYMBOLS POWER SYMBOLS M WS a MOTOR. REFER TO ITEM NUMBER SHOWN IN ELECTRIC EQUIPMENT AND CONTROL SCHEDULE ON DRAWINGS FOR DESCRIPTION. JUNCTION OR PULL BOX 0 a,b RECESSED LIGHT FIXTURE; T = FIXTURE TYPE; "a" INDICATES LIGHT CONTROLLED BY SWITCH WITH SAME DESIGNATION; # INDICATES CIRCUIT BREAKER NUMBER. CEILING MOUNT LIGHT FIXTURE DUPLEX RECEPTACLE, GROUND FAULT CIRCUIT INTERRUPTER TYPE; MOUNT AT 1'-6" AFF UNO; # INDICATES PANEL/CIRCUIT NUMBER # WALL MOUNTED FIXTURE SINGLE POLE SWITCH; "a" INDICATES SWITCH CONTROLS FIXTURE WITH THE SAME DESIGNATION. MOUNT AT 3'-6" AFF UNO. ULTRASONIC WALL SWITCH SENSOR -WATTSTOPPER UW-100-W-120V OR EQUAL. MOUNT IN EXISTING BOX WHEREVER POSSIBLE. AT NEW LOCATIONS MOUNT AT 3'-6" AFF UNO GFCI J FIRE ALARM ANNUNCIATORFAA FIRE ALARM SYMBOLS FIRE ALARM NOTIFICATION APPLIANCE (AUDIO ONLY) HEAT DETECTOR HD F OS3 CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR - WATTSTOPPER WT OR EQUAL. COORDINATE POWER PACK LOCATIONS IN FIELD. GWB/PLASTER CEILING -EXISTING CEILING LEGEND ACT CEILING -2X2 CEILING TAG TYPE HEIGHT AFF FINISH 10'-2 3/8"7 PT-1 Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. ©Filename:Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE no. revision description by date 4/13/2020 11:12:59 AMC:\Projects\BEAR-A-19100-V2018_nhavrish.rvtARCHITECTURE Cornell UniversityA-104 04.15.2020 REFLECTED CEILING PLANSZeta Psi Bathroom Renovations534 Thurston Avenue Ithaca, NY 14850NRH 19100 MAR NRH/MJP 2020 SCALE:1/2" = 1'-0"1 FIRST FL RCP SCALE:1/2" = 1'-0"2 SECOND FL RCP SCALE:1/2" = 1'-0"3 SECOND FL RCP SCALE:1/2" = 1'-0"4 THIRD FL RCP GENERAL ELECTRICAL LIGHTING AND POWER NOTES A ALL WORK SHALL COMPLY WITH NYSBC, THE NEC AND THE NYSECC B REMOVE EXISTING LIGHT FIXTURES. CAP, COIL, AND SECURE IN PLACE BRANCH CIRCUITRY FOR REUSE WITH NEW FIXTURES. CONTROLS SHALL REMAIN FOR REUSE WITH NEW FIXTURES. C PROVIDE NEW LED TYPE LIGHT FIXTURES IN LENGTHS, SIZES, AND MOUNTING CAPABILITY TO MATCH THOSE REMOVED. FOR EXAMPLE A 4'X5" DEEP WALL MOUNTED FIXTURE WITH CENTERED MOUNTING BOX AND WIRING CONNECTIONS SHALL BE REPLACED WITH A 4' WALL MOUNTED FIXTURE OF SIMILAR DIMENSIONS AND CENTER MOUNTAIN/WIRING CAPABILITY. CONNECT NEW FIXTURES TO EXISTING BRANCH CIRCUITING AND CONTROLS. D FIXTURE TYPE A: 24" X 24" LED SURFACE FLAT PANEL, DAMP LOCATION FIXTURE. PROVIDE METALUX 22SP3435RT OR EQUAL. PROVIDE 3400 LUMENS, 80 CRI, 32W, AND 3500K COLOR TEMPERATURE. E FIXTURE TYPE B: 6" DIA. LED WET LOCATION RATED FIXTURE. PROVIDE HALO SLD612-8-35-WH OR EQUAL. PROVIDE WITH 1200 LUMENS, 80 CRI, 14.8W, AND 3500K COLOR TEMPERATURE. F FIXTURE TYPE C: PROVIDE BOBRICK B-169 MIRROR LIGHT WITH CORD AND PLUG. PROVIDE 36" HIGH X 24" WIDE AND 1155 LUMENS. PROVIDE NEW RECEPTACLE AND BRANCH CIRCUIT. CONNECT PLUG TO RECEPTACLE. I PROVIDE OCCUPANCY SENSOR CONTROLS IN ALL SPACES AFFECTED BY THE WORK. IN THE EVENT OCCUPANCY SENSORS ALREADY EXIST, THE CONTRACTOR SHALL CONFIRM THEY ARE OF PROPER WORKING ORDER, REMOVE, SALVAGE AND REINSTALL. LOCATE OCCUPANCY SENSORS TO PROVIDE COVERAGE OF OCCUPANTS INSIDE STALLS WITH DOORS CLOSED. PROVIDE ADDITIONAL SENSORS AS NECESSARY. FOR NEW SENSORS, PROVIDE ALL ACCESSORIES FOR A COMPLETE OCCUPANCY SENSOR SYSTEM. PROVIDE POWER SWITCH PACKS IN AN ACCESSIBLE LOCATION. COORDINATE LOCATIONS IN FIELD. J MAXIMUM INTERIOR LIGHTING POWER ALLOWANCES BY SPACE TYPE: RESTROOM = .98 WATTS/SQ. FT. K WHERE EXISTING EXIT AND/OR EMERGENCY LGHTING IS IMPACTED BY THE WORK, REMOVE, SALVAGE TO REUSE AND REINSTALL IN KIND. NEW EXIT LIGHTS SHALL BE MAXIMUM 5 WATTS PER FACE. L FOR ALL NEW CIRCUIT BREAKERS, PROVIDE DEVICES COMPATIBLE WITH EXISTING PANELBOARDS. MATCH EXISTING AIC RATINGS M DISCONNECT FIRE ALARM DEVICES AND SALVAGE FOR REINSTALLATION IN SAME PLACE. REMOVE SURFACE RACEWAY. RE-WIRE TO CONCEAL WIRING AND RECONNECT DEVICES. N FOR EACH EHD UNIT, PROVIDE 2 #10 AND #10 GND IN 1/2" CONDUIT TO NEAREST AVAILABLE PANELBOARD. PROVIDE 25A/1P BREAKER. CONCEAL WIRING AND RACEWAY WHERE POSSIBLE. CEILING TYPE SCHEDULE MARK MANUFACTUR ER DESCRIPTION FINISH COMMENTS 1 ARMSTRONG OPTIMA, 24 IN x 24 IN x 1 IN, 9/16" SQUARE TEGULAR WHITE 10 YR HUMIGUARD CEILING PANEL WARRANTY, 30 YR CEILING SYSTEM WARRANTY Dx = DEMOLITION KEYNOTE P = PLUMBING E = EQUIPMENT KEYED NOTES LOCATED WITHIN A SPACE SHALL APPLY THROUGHOUT THE SPACE UNLESS OTHERWISE INDICATED. KEYED NOTES DE.5 REMOVE RADIATOR AND SALVAGE TO OWNER FOR REFINISHING. PROVIDE ALL NECESSARY ACCESSORIES, PIPING, FITTINGS, AND PIPE WRAP TO REINSTALL FOLLOWING REFINISHING BY OWNER. E.7 PROVIDE DEDICATED 20A/1P BREAKER AND BRANCH CIRCUIT. PROVIDE 2 #12 AND #12 GND IN 1/2" CONDUIT. CONNECT AT NEAREST AVAILABLE PANELBOARD. CONCEAL WIRING IN EXISTING ADJACENT CONSTRUCTION AND PATCH TO MATCH. E.8 PROVIDE 20A/1P BREAKER AND BRANCH CIRCUIT. PROVIDE 2 #12 AND #12 GND IN 1/2" CONDUIT. CONNECT AT NEAREST AVAILABLE PANELBOARD. CONCEAL WIRING IN EXISTING ADJACENT CONSTRUCTION AND PATCH TO MATCH. E.9 PROVIDE 2 #12 AND #12 GND IN 1/2" CONDUIT. DOES NOT REQUIRE DEDICATED CIRCUIT. AT CONTRACTOR'S OPTION, CONNECT TO SIMILAR FAN MOTOR BRANCH CIRCUIT IN AREA OR PROVIDE DEDICATED 20A/1P BRANCH CIRCUIT TO AVAILABLE PANEL AND PROVIDE BREAKER AS REQUIRED. CONCEAL WIRING IN EXISTING ADJACENT CONSTRUCTION AND PATCH TO MATCH. FIRST FLOOR 100'-0" 12 A-430 1'-5" PROVIDE REMOVABLE PERFORATED METAL SCREEN AT EXISTING RADIATOR -BASIS OF DESIGN: MCNICHOLS WINDSOR 1845 OR EQUAL - COUNTERSINK FASTENERS 16" OC & PROVIDE PLUGS TO MATCH TRIM2'-10"SOLID SURFACE STOOL (SSM-1) MR (24X36) EF-3 2'-10"11"1'-6"TO SHELVES3'-8"FIRST FLOOR 100'-0" PVC TRIM BOARD - TYP ALL FOUR SIDES EXISTING RADIATOR - SALVAGE TO OWNER FOR REFINISHING -CONTRACTOR TO REINSTALL F2 SOLID SURFACE WINDOW STOOL -EXTEND TO INTERSECTING WALLS 1"1"11"2'-10"MR(108X36) 1 1/2" x 1 1/2" ANGLE -SECURE TO WALL, BOTH SIDES OF PLYWOOD PANEL. PROVIDE BLOCKING AS NECESSARY. CUT OUT AT SINK, TYP (2) -3/4" PLYWOOD BETWEEN EVERY SINK -SOLID SURFACE AT EXPOSED ENDS REMOVABLE APRON PANEL OF 3/4" PLYWOOD, PLAM FINISH TO MATCH OWNER STANDARD. ATTACH WITH STAINLESS STEEL SCREWS THROUGH CUPPED FINISH WASHERS. 6"5"VARIES1'-8"9"8"UNO4"2 x 4 BLOCKING INTEGRAL SOLID SURFACE SINK SOLID SURFACE COUNTERTOP WITH INTEGRAL BACKSPLASH AND FORMED APRON2' - 0".2'-10"11"MR (72X36) Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. ©Filename:Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE no. revision description by date 4/13/2020 11:13:02 AMC:\Projects\BEAR-A-19100-V2018_nhavrish.rvtARCHITECTURE Cornell UniversityA-430 04.15.2020 INTERIOR ELEVATIONSZeta Psi Bathroom Renovations534 Thurston Avenue Ithaca, NY 14850NRH 19100 MAR NRH 2020 SCALE:1/4" = 1'-0"13 INTERIOR ELEVATION SCALE:1/4" = 1'-0"2 PRESIDENTS RESTROOM SCALE:1/4" = 1'-0"1 S. ELEVATION - PRESIDENTS SCALE:1/4" = 1'-0"3 PRESIDENTS SHOWER ELEVATION SCALE:1/2" = 1'-0"12 DETAIL AT RADIATOR COVER SCALE:1/4" = 1'-0"4 E. ELEVATION - GUEST RESTROOM SCALE:1/4" = 1'-0"5 N. ELEVATION - GUEST RESTROOM SCALE:1/4" = 1'-0"7 S. ELEVATION - SECOND FL SCALE:1/4" = 1'-0"8 ELEVATION - SECOND FL SCALE:1/4" = 1'-0"9 SINK ELEVATION - SECOND FL SCALE:1 1/2" = 1'-0"6 TYPICAL COUNTERTOP DETAIL SCALE:1/4" = 1'-0"10 SINK ELEVATION - THIRD FL SCALE:1/4" = 1'-0"11 ELEVATION - THIRD FL 1/2" BACKER BOARD WALL FINISH AS SCHEDULED 12 GA. CONTINUOUS 3" WIDE STEEL PLATE SEE "TOILET ROOM ACCESSORYSCHEDULE" FOR GRAB BARMOUNTING HEIGHTSCLEAR 1 1/2" 4" ADJUST CUT TO ADJACENT SURFACE. MAINTAIN 1:2 SLOPE 1/4"1/4"1 2 1/2" FAST SETTING SANDED MODIFIED GROUT PORCELAIN TILE -LARGE MODULE MEDIUM BED MODIFIED MORTAR SELF-LEVELING UNDERLAYMENT PRIMER -DOUBLE APPLICATION EXISTING SOUND/SOLID/BONDED BED MATERIAL TO REMAIN PROVIDE REPAIR MORTAR IN DEEP VOIDS AS NECESSARY *THIS DETAIL INDICATES THE SCOPE OF WORK IN GENERAL. THE AMOUNT OF EXISTING MATERIAL REMOVED AND AMOUNT OF PATCHING AND LEVELING REQUIRED WILL VARY.2" ±REMOVE EXISTING TILE REMOVE ALL LOOSE/UNBONDED BED MATERIAL EXISTING SOUND/SOLID/BONDED BED MATERIAL TO REMAIN EXISTING STRUCTURAL CONCRETE SLAB TO REMAIN *THIS DETAIL INDICATES THE SCOPE OF WORK IN GENERAL. THE AMOUNT OF EXISTING MATERIAL REMOVED AND AMOUNT OF PATCHING AND LEVELING REQUIRED WILL VARY.EXISTINGCERAMIC/PORCELAIN TILE/SOLID SURFACE MATERIAL AS SCHEDULED LATEX PORTLAND CEMENT BOND COAT MORTAR BED WATERPROOF MEMBRANE EXISTING METAL STUD WALL CONSTRUCTION REINFORCED MORTAR BED (1" TO 10") WATERPROOF MEMBRANE SLOPED FILL WHERE REQUIRED AT EXIST SLAB CONSTRUCTION CRUSHED TILE STONES WEEP HOLES FLOOR DRAIN (3/4" TO 1") EXISTING SLAB CONSTRUCTION1/2"EXISTING WALL CONSTRUCTION 1/2" MOISTURE RESISTANT WALLBOARD SHEET APPLIED WATERPROOF MEMBRANE (SCHLUTER-KERDI OR EQUAL) -RUN FULL WALL HEIGHT PREFABRICATED SHOWER PAN THIN SET LATEX MORTAR AND TILE AS SCHEDULED LAP WATERPROOF MEMBRANE PER MANUFACTURER'S SPECIFICATIONS WATERPROOF MEMBRANE (EXTEND BELOW SHOWER PAN) TREATED BLOCKING OR UNDERLAYMENT AS NEEDED TO PROVIDE SLOPE WATERPROOF MEMBRANE LATEX PORTLAND CEMENT BOND COAT PORCELAIN TILE -SLOPE TO SHOWER DRAINS REMOVE EXIST CERAMIC TILE REMOVE TREATED BLOCKINGREMOVE EXIST CERAMIC TILE REMOVE DOOR FRAME REMOVE EXIST MARBLE REMOVE EXIST CERAMIC TILE REMOVE TREATED BLOCKINGREMOVE EXIST CERAMIC TILE REMOVE DOOR FRAME REMOVE EXIST MARBLE ±1"EXISTING SLAB FACE OF WALL ON TOILET ROOM SIDE BEHIND CUT PLANE 2" TYP DOOR & CASING 4'-7" *SIGN TO BASELINE OF BRAILLE CELLS NOTE -PROVIDE TACTILE SIGNAGE OF COLOR, FINISH AND SIZE AS DIRECTED BY OWNER. CONTRAST OF COLOR, RAISED CHARACTERS/ PICTOGRAM, AND GRADE II BRAILLE SHALL COMPLY WITH ICC/ANSI A117.1 (2009) REQUIREMENTS. UNISEX8"8" BRAILLE CENTER JUSTIFY COPY 9" +/-6" +/-BRAILLE RESTROOM ROOM NAME CENTER JUSTIFY Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. ©Filename:Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE no. revision description by date 4/13/2020 11:13:04 AMC:\Projects\BEAR-A-19100-V2018_nhavrish.rvtARCHITECTURE Cornell UniversityA-701 04.15.2020 ROOM FINISH SCHEDULE AND DETAILSZeta Psi Bathroom Renovations534 Thurston Avenue Ithaca, NY 14850NRH 19100 MAR NRH 2020 'S' IN HEADING = SUBSTRATE 'F' IN HEADING = FINISH ROOM FINISH SCHEDULE ROOM NO. ROOM NAME FLOOR WALLS COMMENTS / ROOM FINISHED SCHEDULE KEYED NOTES ROOM NO.SUBSTRATE FINISH BASE NORTH SOUTH EAST WEST FINISH SUBSTRATE FINISH SUBSTRATE FINISH SUBSTRATE FINISH SUBSTRATE FINISH FIRST FLOOR 101B GUEST RESTROOM CONC PFT-1 PTB PLAS CT-1 PLAS/GWB CT-1 PLAS/GWB CT-1/CT-2 PLAS CT-1 NOTE 1 101B 10020 ACCESSIBLE UNISEX RESTROOM CONC PFT-2 PTB PLAS/GWB CT-1 GWB CT-1 GWB CT-1 GWB CT-1 10020 SECOND FLOOR 20020 TOILET / SHOWER ROOM CONC PFT-2 PTB PLAS PFT-1/CT-1 PLAS/GWB PFT-1/CT-1 PLAS PFT-1/CT-1 PLAS/GWB CT-2/CT-1/SSM-2 NOTE 1 20020 20021 PRESIDENTS RESTROOM CONC PFT-2 PTB GWB PFT-1 GWB PFT-1 GWB PFT-1 GWB PFT-1 20021 THIRD FLOOR 30020 TOILET / SHOWER ROOM CONC PFT-2 PTB PLAS PFT-1/CT-1 PLAS/GWB PFT-1/CT-1 PLAS PFT-1/CT-1 PLAS/GWB CT-2/CT-1/SSM-2 NOTE 1 30020 ROOM FINISH SCHEDULE KEYED NOTES 1 PROVIDE CT-2 AT SINK WALL/ALCOVE ONLY. COORDINATE EXTENTS WITH PLANS AND INTERIOR ELEVATIONS. SCALE:3" = 1'-0"5 GRAB BAR DETAIL SCALE:1 : 16MARBLE THRESHOLD SCALE:3" = 1'-0"1 TILE FLOOR DETAILS SCALE:3" = 1'-0"4 SHOWER BASE DETAIL SCALE:3" = 1'-0"3 TYP SHOWER PAN DETAIL SCALE:3" = 1'-0"7 SHOWER CURB DETAILS PFT = PORCELAIN FLOOR TILE PTB = PORCELAIN TILE BASE CT = CERAMIC TILE SSM = SOLID SURFACE MATERIAL HDPE = HIGH DENSITY POLYETHYLENE PNT = PAINT FINISH MATERIAL LEGEND MARK MANUFACTURER DESCRIPTION COLOR SIZE COMMENTS CT-1 DALTILE ANNAPOLIS MATTE SAND AP11 6" X 16" STAGGERED BRICK JOINT PATTERN CT-2 DALTILE COLOR WAVE GLASS MOSAIC TILE, GLOSSY STRAIGHT JOINT CASHMERE CW22 1" X 1" ACCENT TILE PFT-1 DALTILE SLATE ATTACHE MATTE META LIGHT GRAY SA06 24" X 24" PTB BULLNOSE TRIM PFT-2 DALTILE SLATE ATTACHE MATTE META DARK GRAY SA07 24" X 24" PTB BULLNOSE TRIM PNT-1 SHERWIN WILLIAMS INTERIOR LATEX SATIN BATH PAINT AS SELECTED BY ARCHITECT -- AT EXIST GWB/PLASTER CEILINGS SSM-1 DUPONT CORIAN NATURAL GRAY 1/4" X 30" X 144" AT SINKS/WINDOW STOOLS SSM-2 DUPONT CORIAN WHIPPED CREAM 1/4" X 30" X 144" AT SHOWER WALLS WHERE INDICATED GENERAL FINISH NOTES A THESE GENERAL NOTES APPLY TO NEW SPACES AND EXISTING SPACES AFFECTED BY THE WORK B THE ROOM FINISH SCHEDULE IS GENERAL IN NATURE, AND IS INTENDED AS A SUMMARY OF THE DESIRED FINISHES FOR EACH SPACE LISTED, BUT MAY NOT REPRESENT ALL OF THE FINISHES REQUIRED TO COMPLETE THE WORK. THE ROOM FINISH SCHEDULE AND THE REMAINDER OF THE CONSTRUCTION DOCUMENTS ARE COMPLIMENTARY, AS ADDITIONAL FINISH INFORMATION MAY BE INDICATED THROUGHOUT C SHOULD CONFLICTS EXIST WITHIN THE CONSTRUCTION DOCUMENTS, VERIFY INTENT WITH ARCHITECT PRIOR TO BIDDING. CLARIFICATIONS ISSUED AFTER BIDDING SHALL NOT BE BASIS FOR ADDITIONAL COMPENSATION D COLORS/TEXTURES INDICATED ARE THOSE OF THE BASIS-OF-DESIGN MANUFACTURER/FINISH. APPROVED SUBSTITUTIONS SHALL BE PROVIDED IN COLOR/TEXTURE MATCHING THE BASIS-OF-DESIGN, INCLUDING CUSTOM COLORS/TEXTURES, AT NO ADDITIONAL COST E WHERE COLORS/TEXTURES ARE NOT INDICATED, THEY SHALL BE SELECTED FROM FULL RANGE OF OPTIONS FROM BASIS-OF-DESIGN MANUFACTURER. APPROVED SUBSTITUTIONS SHALL BE PROVIDED IN COLOR/TEXTURE MATCHING THE FULL RANGE OF OPTIONS FROM BOTH THE SUBSTITUTE AND BASIS-OF-DESIGN MANUFACTURERS’ FULL RANGE OF OPTIONS, INCLUDING CUSTOM COLORS/TEXTURES, AT NO ADDITIONAL COST F IT IS INTENDED THAT EXPOSED AND SEMI-EXPOSED SURFACES SHALL RECEIVE FINISH, EVEN IF NOT SPECIFICALLY INDICATED IN THE CONSTRUCTION DOCUMENTS G PROVIDE PREPARATION OF SURFACES TO RECEIVE FINISH PER MANUFACTURER’S RECOMMENDATIONS, UNLESS OTHERWISE INDICATED H PAINT WALLS TO MATCH ADJACENT FINISHES UNLESS OTHERWISE INDICATED, OR DIRECTED BY THE OWNER OR OWNER'S REPRESENTATIVE I PAINT HM DOORS AND FRAMES TO MATCH EXISTING UNLESS OTHERWISE INDICATED, OR DIRECTED BY THE OWNER OR OWNER'S REPRESENTATIVE K PAINT EXPOSED STRUCTURAL ELEMENTS AND EXPOSED MISCELLANEOUS METALS EMBEDDED IN WALLS TO MATCH ADJACENT SURFACE UNLESS OTHERWISE INDICATED L PAINT EXPOSED WOOD GROUNDS, BACKERS, FILLERS, SPACERS AND OTHER UNFINISHED COMPONENTS ASSOCIATED WITH INSTALLATION OF EQUIPMENT OR ACCESSORIES TO MATCH ADJACENT SURFACE UNLESS OTHERWISE INDICATED M PAINT EXPOSED UNFINISHED PIPING, CONDUITS, JUNCTION BOXES, ETC. TO MATCH ADJACENT SURFACE UNLESS OTHERWISE INDICATED N PAINT ACCESS DOORS TO MATCH ADJACENT SURFACE UNLESS OTHERWISE INDICATED O WHERE HVAC GRILLES AND REGISTERS ARE INSTALLED IN WALLS OF DISSIMILAR COLOR, PAINT TO MATCH ADJACENT SURFACE UNLESS OTHERWISE INDICATED Q FLOOR FINISH SHALL CONTINUE UNDER OPEN BASE CASEWORK/MILLWORK AND OPEN COUNTERS S PROVIDE NEW BASE WHEREVER NEW FLOORING IS INSTALLED T WHERE COUNTER FINISH IS NOT INDICATED PROVIDE SSM-1 U PROVIDE SEALANT WHERE COUNTERS/BACKSPLASHES MEET OTHER CONSTRUCTION, AFTER PAINTING IS COMPLETE: TYPE AND COLOR TO BE SELECTED BY ARCHITECT V FLOOR FINISH TRANSITIONS SHALL OCCUR AT FACE OF DOOR AT FRAME STOPS. AT TRANSITIONS BETWEEN MATERIALS OF UNEVEN THICKNESS, HIGH SIDE OF TRANSITION SHALL BE INSTALLED AT FACE OF DOOR AT FRAME STOPS. AT AMBIGUOUS CONDITIONS VERIFY INTENT WITH ARCHITECT PRIOR TO FLOORING INSTALLATION SCALE:1/4" = 1'-0"9 SIGNAGE & MOUNTING LOCATION SCALE:3" = 1'-0" SIGN TYPE 1 SIGNAGE SCHEDULE ROOM NUMBER ROOM NAME SIGNAGE TEXT SIGN TYPE 10020 ACCESSIBLE UNISEX RESTROOM UNISEX TYPE 1 20020 TOILET / SHOWER ROOM RESTROOM TYPE 2 30020 TOILET / SHOWER ROOM RESTROOM TYPE 2 SCALE:3" = 1'-0" SIGN TYPE 2 SUPPLY RISER TYPICAL BRANCH LINE WATER HAMMER ARRESTOR PDI "A" PDI SYMBOL NOTES: 1. INSTALL WATER HAMMER ARRESTOR AT THE END OF BRANCH LINE BETWEEN THE LAST TWO FIXTURES SERVED. 2. PROVIDE ONE WATER HAMMER ARRESTOR PER 20'-0" IN LENGTH. 3. THE SUM OF FIXTURE UNIT RATING OF UNITS OVER 20'-0" IN LENGTH SHALL BE EQUAL TO OR GREATER THAN THE DEMAND OF THE BRANCHES. WC-1 LAV-1 CO CO CO CO LAV-2 WC-2 SH-1 2" V 2" 4" EX 4" STACK E X S A N EX SAN 2" 2" 2" V 4" 2" V FD-1 FD-1 3" WC-1 LAV-1 SH-1 WC-2 LAV-2 1/2" 1/2" 1/2" 3/4" 1" 1/2" EX 3/4" H W R EX 1" H W EX 2" C W EX 1" C W HB-1 3/4"HWCWH W C W SH-3 LAV-2 WC-1 EX 4" VENT EX VENT CO EX 4" SAN SH-3 LAV-2 WC-1 EX 4" EX 4" OPTIONAL FUNNEL SECURE TO GRATE COLLAR CONCRETE FLOOR FINISHED FLOOR ADJUSTABLE HOUSING REMOVABLE STRAINER Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. ©Filename:Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE no. revision description by date 4/13/2020 11:13:09 AMC:\Projects\BEAR-A-19100-V2018_nhavrish.rvtPLUMBING Cornell UniversityP-101 04.15.2020 DETAILS AND SCHEMATICSZeta Psi Bathroom Renovations534 Thurston Avenue Ithaca, NY 14850BMM 19100 NRH/MAR DJW 2020 WATER HAMMER ARRESTOR SCHEDULE (SA) PDI SYMBOL A B C D E F FIXTURE UNIT RATING 1-11 12-32 33-60 61-113 114-154 155-330 SCALE:NOT TO SCALE5WATER HAMMER ARRESTOR DETAIL SCALE:NOT TO SCALE1FIRST FLOOR SANITARY PIPING SCHEMATIC SCALE:NOT TO SCALE2FIRST FLOOR DOMESTIC WATER PIPING SCHEMATIC SCALE:NOT TO SCALE3 PRESIDENT TOILET ROOM DOMESTIC WATER PIPING SCHEMATIC SCALE:NOT TO SCALE4 PRESIDENT'S TOILET ROOM SANITARY PIPING SCHEMATIC SCALE:NOT TO SCALE6FLOOR DRAIN DETAIL S A N EX SANV E X S A N V V S A N V V 4" EX SAN 1 1/2" 3" WC-1 WC-1FD-1 4" 4" UR-1 FD-1 WC-1 WC-1 4" 3" 3" 3" 1 1/2" 3" V 4" FROM 1ST FLOOR TOILET ROOM 2" 1 1/2" TYP 1 1/2" WPCO EX 4" EX 4" 1 1/2" 2" WPCO EX 2" V 4" V LAV-4 LAV-3 CO C W 3/4" 1/2" 1/2" SH-2 SH-2 EX SA WC-1 WC-1 1" 1 1/2" 1 1/2" 1" 3/4" HW EX HWEX HWREX CW1" 3/4" 1/2" 1/2" 1/2" SH-2 3/4" 3/4" 1" 1 1/2" SH-2 SH-2 WC-1 WC-1 UR-1 3/4" 1" 1" 1 1/2" EX 2" CW EX 1" HW EX 3/4" HWR PROVIDE TRAP PRIMER VALVE SEE DETAIL 2\G-003 PROVIDE TRAP PRIMER VALVE SEE DETAIL 2/G-003 LAV-3 HB-1 PROVIDE 1/2" TRAP PRIMER LINE LAV-4 PROVIDE 1/2" TRAP PRIMER LINE HB-1 1" 3/4" 1/2" 3/4" 1/2" E X H W E X C W EX SA Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. ©Filename:Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE no. revision description by date 4/13/2020 11:13:10 AMC:\Projects\BEAR-A-19100-V2018_nhavrish.rvtPLUMBING Cornell UniversityP-102 04.15.2020 DETAILS AND SCHEMATICSZeta Psi Bathroom Renovations534 Thurston Avenue Ithaca, NY 14850BMM 19100 NRH/MAR DJW 2020 SCALE:NOT TO SCALE1SECOND AND THIRD FLOOR WASTE PIPING SCHEMATIC SCALE:NOT TO SCALE2 SECOND AND THIRD FLOOR DOMESTIC WATER PIPING SCHEMATIC