Loading...
HomeMy WebLinkAboutDrawings_Duffield Hall 330 Lab RenovationsCB CB CB CB CB CB CB CB CB CBCB CB CB CBCBCB CBCBCB 191920202021212121202020201919 191920202021212121202020201919 191920202021212121202020201919 191920202021212121202020201919 1919202020212121212020202019191919212020202021 2121212121212121212121212121 STANDS S/PSCOREBOARD ATHLETIC FIELD FP PARKINGPAVED UNPAVED TENNIS COURT TENNIS COURT TENNIS COURTS SS S DN DN BENCHBENCH UPDN UP DN UP DN UPDN DN HOY ROAD 2000 DUFFIELD HALL CAMPUS ROAD CAMPUS ROAD EXTERIOR ELEVATION 1 X-100 X-100 1 1 INTERIOR ELEVATION 1 X-100 SECTION MARKER 1 X-100 ENLARGED DETAIL CONSTRUCTION KEYED NOTE DEMOLITION KEYED NOTE DRAWING REVISION NOTE LINETYPE: TO BE PROVIDED / NEW LINETYPE: DEMOLITION / TO BE RELOCATED LINETYPE: EXISTING TO REMAIN # # # 1 1 1 11 AREA OF WORK PHILLIPS HALLDUFFIELD HALL ATRIUM APPLICABLE CODES 2020 NYS BUILDING CODE 2020 NYS EXISTING BUILDING CODE 2020 NYS FIRE CODE 2020 NYS PLUMBING CODE 2020 NYS MECHANICAL CODE 2020 NYS ENERGY CONSERVATION CODE 2009 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2010 AMERICANS WITH DISABILITY ACT (ADA) PROJECT SUMMARY THIS PROJECT INCLUDES THE RENOVATION OF ONE 536 SF WET LABORATORY SPACE. IT IS EXPECTED THAT THE AMOUNT OF TOXIC CHEMICALS WILL EXCEED THE MAXIMUM ALLOWABLE QUANTITY FOR A HIGHER EDUCATION LABORATORY SUITE. THEREFORE, ROOM 330 WILL BE CONVERTED TO AN H-4 OCCUPANCY AND SEPARATED FROM THE PREVIOUSLY ESTABLISHED CONTROL AREA 1. ALTERATION LEVEL 2: LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENTION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. AN EXISTING BUILDING OR PORTION THEREOF SHALL NOT BE ALTERED SUCH THAT THE BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITIONS. BUILDING LIMITATIONS CONSTRUCTION CLASSIFICATION:IB CLASSIFICATION OF HAZARDS:WORK AREA H-4 -MAQ UPON REQUEST HIGH-RISE BUILDING:NO EXTINGUISHING REQUIREMENT:THE EXISTING DUFFIELD/PHILLIPS COMPLEX IS PARTIALLY SPRINKLERED (DUFFIELD HALL IS SPRINKLERED, PHILLIPS HALL IS PARTIALLY SPRINKLERED) OCCUPANCY OF THIRD FLOOR OCCUPANCY CLASSIFICATION:SEPARATED MIXED USE: BUSINESS (B)AND HIGH-HAZARD (H-2, H-4, AND H-5) T-001 TITLE SHEET ARCHITECTURAL A-001 CODE COMPLIANCE PLAN, GENERAL NOTES A-101 PLANS, 3D, AND EQUIPMENT LIST PLUMBING P-001 GENERAL NOTES AND SYMBOL LEGENDS P-101 PARTIAL SECOND AND THIRD FLOOR PLUMBING FLOOR PLANS MECHANICAL M-001 GENERAL NOTES AND SYMBOL LEGENDS M-101 PARTIAL THIRD FLOOR MECHANICAL FLOOR PLANS M-401 CONTROLS M-501 SCHEDULES AND DETAILS ELECTRICAL E-001 GENERAL NOTES AND SYMBOL LEGENDS E-101 POWER, DATA, LIGHTING, AND FIRE ALARM PARTIAL THIRD FLOOR PLANCORNE LL U N I V E R SI TYFOUN D E D 5681AD CORN E LL U N I V E R SI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 Cornell University 343 CAMPUS ROAD ITHACA, NEW YORK 14850 DUFFIELD HALL 330 LAB RENOVATIONS T-001 12672500 TITLE SHEET FE DESIGN NH 2000 SEPTEMBER 4, 2020 DUFFIELD HALL 330 LAB RENOVATIONS BUILDING CODE SUMMARYGENERAL SYMBOLS LEGEND DRAWING INDEX PROJECT SCOPE PERSPECTIVE VIEWSITE LOCATION -DUFFIELD HALL KEY PLAN DUFFIELD / PHILLIPS COMPLEX -THIRD FLOOR THIS PROJECT INCLUDES THE RENOVATION OF ONE 536 SF WET LABORATORY SPACE AND PARTIAL CONVERSION OF AN ESTABLISHED B OCCUPANCY TO AN H-4 OCCUPANCY. 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% REVIEW 3 08/28/2020 ISSUE FOR CONSTRUCTION 324 324B 324A 328 300CA 327322 301300 302 305 308 310 311 312 315 316 756 558 255 1276 519 157 15 29 1093 95 517 45 178 173 113 531 521 246 538 767 555 213 211 53 450 33 641 45 126 29 408 212 1295 568 315 132 903 116 170 69 99 131 252 137123123 230 118 203 62 561 70 1979 1022352 1391 151 104 183 71 185 106 86 62 1010 64 223 574 314 146 122121 75 9 231 138 262 253 182 35 188 175 36 559 722 317 598 737 42 1755 720 493 736 622 62 139 205 511 963 294 458 365 652 574 638 116 266 849 108 367 108 99 589 2290 522512 230 396 189 194 195 194 194 195 195 186 308 302 309 313 30061 30062 30072 305 323 30040 304 30043 30023 30041 320 30042 324 327 328 330 336 334 30020 30060 30021 30046 30001 340 340B 340A 30073 352 354 356 358 362 30002 350L 350 350M 350A 350N 350B 350C 350D 350E350F350G 350H 350J 30047 30003 30052 30075 BRIDGE30006301 BRIDGE 344 344A 344B 320A 370 372 371 308A 316 316A 331A 331BALCONY ATRIUMOPEN TOBELOW ATRIUMOPEN TOBELOW 360 360A 360B360C 309A 350P 331330 300CB 319 318 314 323 325 329300SA300E300UA 300J 300CC 336 334 337 338 338A 339 338B339A 339B 300UB 338C 303 307 309 300SB 300TA 300TB 332 300CE 300CD 300SC DN DN BENCHBENCH UP DN UP DN UP DN UPDN DN 324 324B 324A 328 300CA 327322 301300 302 305 308 310 311 312 315 316 756 558 255 1276 519 157 15 29 1093 95 517 45 178 173 113 531 521 246 767 555 213 211 53 450 33 641 45 126 29 408 212 1295 568 315 132 903 116 170 69 99 131 252 137123123 230 118 203 62 561 70 1979 1022352 1391 151 104 183 71 185 106 86 62 1010 64 223 574 314 146 122121 75 9 231 138 262 253 182 35 188 175 36 559 722 317 598 737 42 1755 720 493 736 622 62 139 205 511 963 294 458 365 652 574 638 116 266 849 108 367 108 99 589 2290 522512 230 396 189 194 195 194 194 195 195 186 308 302 309 313 30061 30062 30072 305 323 30040 304 30043 30023 30041 320 30042 324 327 328 336 334 30020 30060 30021 30046 30001 340 340B 340A 30073 352 354 356 358 362 30002 350L 350 350M 350A 350N 350B 350C 350D 350E350F350G 350H 350J 30047 30003 30052 30075 BRIDGE30006301 BRIDGE 344 344A 344B 320A 370 372 371 308A 316 316A 331A 331BALCONY ATRIUMOPEN TOBELOW ATRIUMOPEN TOBELOW 360 360A 360B360C 309A 350P 331330 300CB 319 318 314 323 325 329300SA300E300UA 300J 300CC 336 334 337 338 338A 339 338B339A 339B 300UB 338C 303 307 309 300SB 300TA 300TB 332 300CE 300CD 300SC DN DN BENCHBENCH UP DN UP DN UP DN UPDN DN WALL -EXISTING WALL -METAL STUD/ GWB WALL -CONCRETE WALL -CMU WALL -BRICK ITEMS FOR DEMOLITION DOOR/ WALL -EXISTING DOOR/ WALL -NEW DOOR/ WALL -DEMOLITION TAG -DOOR TAG -WINDOW TAG -WALL TAG -ROOM # CENTER LINE PHOTO REFERENCE LEVEL MARKER COLUMN GRID MARKER ELEVATION MARKER ELEVATION CHANGE ARROWS BREAK LINE SYMBOLS 0' -0" 101 1t X-X X 2B00UA CL 1 Name Elevation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i.e. DUCT/PIPE REMOVALS, ETC.) AT WALLS, ROOF OR FLOOR TO BE INFILLED SOLID. 6.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE WORK OF OTHER TRADES (i.e. ELECTRICAL, MECHANICAL). ALTHOUGH NOT NECESSARILY SHOWN ON DRAWINGS, WORK IS REQUIRED IN THESE AREAS CONSISTING OF REMOVAL / REPLACEMENT OF CEILINGS, WALLS, FINISHES, PAVEMENT AND OTHER CONSTRUCTION AS NECESSARY TO PERFORM WORK AND RESTORE THESE SPACES OR AREAS TO ORIGINAL CONDITION. 7.0 GENERAL CONTRACTOR IS TO COORDINATE WORK OF ALL TRADES. SCHEDULE WORK PROGRESS THROUGHOUT THE ENTIRE PROJECT TO PREVENT CONFLICTS AND INTERFERENCES. OBTAIN ALL NECESSARY INFORMATION SUCH AS SIZES, LOCATIONS, TEMPLATES, LAYOUT, DIMENSIONS AND ALL OTHER INFORMATION NECESSARY FOR A PROPER AND WELL COORDINATED INSTALLATION. PRIOR TO INSTALLATION OF ITEMS, VERIFY AND CONFIRM WITH EACH CONTRACTOR EXACT LOCATION OF ALL ITEMS. 8.0 ALL PENETRATIONS (EXISTING OR NEW) THROUGH FLOORS AND FULL HEIGHT WALLS - IN AREA OF WORK TO BE FIRE STOPPED. ALL GAPS AND JOINTS AT RATED FLOORS, ROOFS AND WALLS TO BE FIRE & SMOKE STOPPED. GAPS AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND CONTROL OR EXPANSION JOINTS. FIRE STOPPING INCLUDES BOTH FORM OR PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. PROVIDE AND INSTALL LABELING REQUIRED BY CODE. LABELS SHALL INCLUDE PENETRATION TYPE WITH UL LISTING USED, MATERIAL USED, DATE INSTALL AND NAME OF INSTALLER. 9.0 JOBSITE WILL BE CLEANED DAILY AND DEBRIS REMOVED TO CONTAINERS OR TO VEHICLE WHICH WILL REMOVE DEBRIS FROM CAMPUS. CONTAINERS WILL BE REMOVED AS SOON AS FULL OR WHEN THE PROJECT HAS PROGRESSED TO A POINT THAT A CONTAINER IS NO LONGER REQUIRED. 10.0 CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL AREAS USED TO BRING SUPPLIES AND EQUIPMENT INTO THE PROJECT AREA. ANY DAMAGE TO AREAS OUTSIDE THE PROJECT AREA INCLUDING BUT NOT LIMITED TO THE LOBBY AND CORRIDOR SHALL BE REPAIRED AT NO COST TO THE OWNER. SCALE:1" = 40'-0"2 DUFFIELD 330 - CODE COMPLIANCE PLAN SCALE:1" = 40'-0"1 DUFFIELD / PHILLIPS COMPLEX - THIRD FLOOR CONTROL AREAS BUILDING CODE SUMMARY 0'20' 40' 80' SCALE: 1"=40'-0" 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% REVIEW 3 08/28/2020 ISSUE FOR CONSTRUCTION SUBMITTAL REGISTRY TITLE REQUIRED SUBMITTALS 07 84 13 - PENETRATION FIRESTOPPING PRODUCT DATA 07 92 00 - SEALANTS PRODUCT DATA 09 91 23 - INTERIOR PAINTING PRODUCT DATA, SAMPLES 10 20 00 - INTERIOR SPECIALTIES CURTAIN AND TRACK PRODUCT DATA, SHOP DRAWINGS 11 53 13 - LABORATORY FUME HOODS PRODUCT DATA, SHOP DRAWINGS 12 35 53 - LABORATORY CASEWORK PRODUCT DATA, SHOP DRAWINGS 2 1 2 3 5 56 4 7 PDMS STATION CLEAN FAB BENCH COMMON FAB BENCH TRAINEE BENCH 1 TRAINEE BENCH 2 SOFT MATTER E19 E20 E21 E22 1 2 3 4 5 6 6' - 6"13' - 1"6 8 12 12 11 11 7 7 10 9 13 E23 EXISTING ELECTRICAL RACEWAY ABOVE 536 SF EXG EXG 330 EXG PT-1* 15 16 E18.1 E18.2 3' - 6" 17 18 19 19 17 17 330-1 20 20 20 20 14 6 6 ROOM NUMBER CEILING FINISH WALL FINISH FLOOR FINISH WALL BASE ROOM AREA SEE SCHD F12"D1 SEE SCHD.SEE SCHD. HOLLOW METAL DOORS AND FRAMES: • CURRIES "HM DOUBLE FLUSH FIRE DOORS" OR APPROVED EQUAL 1. 18 GAGE MIN. • CURRIES "THREE SIDED FIRE DOOR FRAME" OR APPROVED EQUAL 1. "M" PROFILE 2. 16 GAGE 3. SEAM WELDED CONSTRUCTION 4. 5 7/8" JAMB DEPTH 5. 2" HEAD DOOR HARDWARE SET #1: 8 Hinges: McKinney TA2714 x 4 1/2" x 4 1/2" x 26D 1 Lockset: Sargent Entry Lock 8255 LNL US10 1 Door Closer: Sargent 351 P9 2 Kick Plates: Rockwood K1050A-6, US10, Match existing height 2 Gasketing: Pemko S773BL 1 Flush Bolt:Rockwood 2848 CORN E LL U N I V E R SI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 343 CAMPUS ROAD ITHACA, NEW YORK 14850 DUFFIELD HALL 330 LAB RENOVATIONS A-101 12672500 PLANS, 3D, AND EQUIPMENT LIST N.HACHMANN NH 2000 SEPTEMBER 4, 2020 A-101 KEYED RENOVATION NOTES 1 FOLLOWING REMOVAL OF WALL CABINETS, PATCH ALL HOLES IN WALLS AND PREPARE FOR TOUCH-UP PAINT. 2 TOUCH UP PAINT WITH PT-1. ASSUME 25% OF ALL WALL AREA IN THE ROOM. 3 PAINT MISCELLANEOUS EXPOSED DUCTWORK, PIPING AND CONDUIT TO MATCH ADJACENT SURFACE. DO NOT COVER UP UTILITY LABELING. 4 REINSTALL SUSPENDED CEILING SYSTEM AFTER THE COMPLETION OF MECHANICAL, ELECTRICAL, AND PLUMBING WORK. REPLACE ANY DAMAGED PIECES WITH NEW ACOUSTICAL CEILING PANELS AND GRID TO MATCH EXISTING. 5 FURNISH AND INSTALL ADA SINK CABINET. BASIS OF DESIGN MODEL: MOTT "KNEE SPACE SINK CABINET" 15K3011W WITH STEPPED SINK, 48"W x 24"D x 31-3/4"H, WOOD, ADA COMPATIBLE, WITH 1" BLACK EPOXY RESIN COUNTER. COORDINATE WITH PLUMBING SCOPE. 6 FURNISH AND INSTALL CURTAIN AND MOUNTING HARDWARE, FULL HEIGHT (PROVIDE ALL HARDWARE TO ATTACH TO GRID OF 10'-0" ACOUSTICAL CEILING). BASIS OF DESIGN MODEL: GOFF'S ENTERPRISES CURTAIN WALLS "WELD CURTAIN", YELLOW WELD VIEW COLOR, WHITE 14 OZ VINYL COLOR, COLOR MATCHING FLOOR SWEEPS. TWO SEPARATE TRACKS AND CURTAINS OVERLAPPING BY 2-FEET AT CENTER OF LONG SIDE TO ACT AS DOOR OPENING 7 FURNISH AND INSTALL WOOD TABLE WITH 1" BLACK EPOXY RESIN TOP. BASIS OF DESIGN MODEL: MOTT "WOOD TABLE WITH U-FRAME", 72"W x 36"D, STANDING HEIGHT. 8 INSTALL OWNER-FURNISHED TABLE WITH VENTED ENCLOSURE. COORDINATE WITH MEP SCOPE 9 INSTALL OWNER-FURNISHED VENTED ENCLOSURE. COORDINATE WITH MEP SCOPE. 10 FURNISH AND INSTALL WOOD TABLE WITH 1" BLACK EPOXY RESIN TOP. BASIS OF DESIGN MODEL: MOTT "WOOD TABLE WITH U-FRAME", 60"W x 36"D, STANDING HEIGHT. 11 REINSTALL SALVAGED TABLE 12 INSTALL OWNER-FURNISHED STAINLESS-STEEL TABLE 13 SEE MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION DRAWINGS FOR SCOPE INFORMATION 14 AT LOCATION OF DEMOLISHED LIGHT FIXTURE, FILL IN ACOUSTICAL PANEL CEILING TO MATCH EXISTING. 15 FURNISH AND INSTALL WOOD CABINET ON CASTERS WITH 1" BLACK EPOXY RESIN TOP AND PULL BAR. BASIS OF DESIGN MODEL: MOTT "WOOD MOBILE CABINET WITH DRAWER/DOOR UNIT 1110022W", 18"W, STANDING HEIGHT. CONFIRM HEIGHT FITS UNDER WOOD TABLE. 16 FURNISH AND INSTALL WOOD CABINET ON CASTERS WITH 1" BLACK EPOXY RESIN TOP AND PULL BAR. BASIS OF DESIGN MODEL: MOTT "WOOD MOBILE CABINET WITH DRAWER UNIT 1110044W", 18"W, STANDING HEIGHT. CONFIRM HEIGHT FITS UNDER WOOD TABLE. 17 FURNISH AND INSTALL A TOTAL OF (3) LAB STOOLS. BASIS OF DESIGN MODEL: BIOFIT "TRAXX, MODEL NR. TXA-M-RC-S-XF-XA-06" 18 FURNISH AND INSTALL (1) LAB STOOLS. BASIS OF DESIGN MODEL: BIOFIT "LX SIT/STAND, MODEL NR. LXS-M-HG-L-XF-X-06" 19 FURNISH AND INSTALL A TOTAL OF (2) LAB STOOLS. BASIS OF DESIGN MODEL: BIOFIT "ARMOR-SEAT, MODEL NR. GGR-M-RC" 20 IN WORK AREA INSPECT EXISTING PARTITONS UP TO DECK. USE APPROPRIATE FIRE-STOPPING MATERIAL TO FILL IN ANY OPEN PENETRATIONS TO CONFIRM FIRE RATING IN WORK AREA AS INDICATED ON CODE COMPLIANCE PLAN. # A-101 KEYED DEMOLITION NOTES 1 HAZARDOUS MATERIALS ARE NOT EXPECTED. ALERT OWNER IF ENCOUNTERING SUSPICIOUS MATERIAL. OWNER WILL PERFORM REMOVAL OF ASBESTOS AND PCB CONTAINING MATERIAL. 2 REMOVE EXISTING WALL CABINETS WHERE NOTED. 3 CUT COUNTERTOP AND REMOVE EXISTING SINK CABINET. COORDINATE WITH MEPFP DRAWINGS. 4 CAREFULLY REMOVE EXISTING TALL CABINET AND TURN OVER TO OWNER. MOVE ITEM TO DUFFIELD PENTHOUSE OR WHERE DIRECTED BY OWNER. 5 CAREFULLY REMOVE EXISTING FURNISHING. STORE AND REINSTALL IN NEW LOCATION FOLLOWING COMPLETION OF NEW CONSTRUCTION WORK. SEE RENOVATION NOTE 11. 6 CAREFULLY REMOVE THE PORTION OF THE EXISTING SUSPENDED CEILING SYSTEM AS REQUIRED TO PERFORM MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION WORK. SALVAGE FOR REINSTALLATION AFTER COMPLETION OF MEPFP WORK. 7 REMOVE EXISTING DOOR AND FRAME COMPLETELY. PATCH ADJACENT SURFACES AND PREPARE FOR INSTALLATION OF NEW DOOR. # 0' 2' 4' 8' SCALE: 1/4"=1'-0" SCALE:1/4" = 1'-0"3 PARTIAL THIRD FLOOR DEMOLITION PLAN SCALE:1/4" = 1'-0"4 PARTIAL THIRD FLOOR PLAN SCALE:NO SCALE13D VIEW LOOKING EAST SCALE: NO SCALE 2 3D VIEW LOOKING WEST SCALE:1/4" = 1'-0"5 PARTIAL THIRD FLOOR RCP EQUIPMENT LIST EXG EXISTING TO REMAIN PT-1 PAINT -INTERIOR WALLS BENJAMIN MOORE, COLOR: 912 "LINEN WHITE", EGGSHELL PT-2 PAINT -HM DOOR AND DOOR FRAME BENJAMIN MOORE, COLOR: MATCH EXISTING, SEMI-GLOSS FINISH LEGEND (BASIS-OF-DESIGN PRODUCTS) 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% REVIEW 3 08/28/2020 ISSUE FOR CONSTRUCTION DOOR / HARDWARE SCHEDULE DOOR DOOR FRAME FIRE RATINGGLAZING TYPEDETAILS REMARKSDOOR LOCATION HAND PANEL SIZE ELEVATION TYPEMATERIALFINISHELEVATION TYPEMATERIALFINISHHEAD DIM.HARDWARE SETTHRESHOLDWIDTHHEIGHTTHICKNESS 330-1 330 TO SERVICE CORRIDOR LHR 8' - 10" 1 3/4" D HM PT-2 F HM PT-2 2" 45 MIN. - - 1 - - 5'-0" + 2'-0" CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 343 CAMPUS ROAD ITHACA, NEW YORK 14850 DUFFIELD HALL 330 LAB RENOVATIONS P-001 12672500 GENERAL NOTES AND SYMBOL LEGENDS E. LEPORE TRF 2000 SEPTEMBER 4, 2020 PLUMBING SUBMITTAL SCHEDULE SECTION REQUIRED TITLE 220523 GENERAL DUTY VALVES FOR PLUMBING PIPING PRODUCT DATA 220529 HANGERS & SUPPORTS FOR PLUMBING PRODUCT DATA 220553 ID FOR PIPING AND EQUIPMENT PRODUCT DATA 220719 PLUMBING PIPING INSULATION PRODUCT DATA 221000 PLUMBING PIPING PRODUCT DATA 221116 DOMESTIC WATER PIPING PRODUCT DATA,TESTING 221118 PURE WATER PIPING SYSTEMS PRODUCT DATA,TESTING 223000 PLUMBING EQUIPMENT PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 224500 LABORATORY PLUMBING FIXTURES AND TRIM PRODUCT DATA 226001 NITROGEN PIPING SYSTEMS PRODUCT DATA,TESTING 226113 LABORATORY COMPRESSED AIR PIPING PRODUCT DATA,TESTING 226213 LABORATORY VACUUM PIPING PRODUCT DATA,TESTING 226653 LAB WASTE & LAB VENT PIPING PRODUCT DATA,TESTING PLUMBING SCOPE OF WORK 1.0 EXTEND EXISTING LAB PLUMBING SERVICES TO RESEARCH EQUIPMENT. 2.0. PROVIDE AN ADA SINK FAUCET. 3.0 PROVIDE A QUALITY WATER FAUCET. 4.0 PROVIDE AN EMERGENCY EYEWASH. PLUMBING FIXTURE SCHEDULE & SPEC TAG COMPONENTS MANUFACTURER MODEL DESCRIPTION MATERIAL FINISH / COLOR COLD WATER HOT WATER RODI WASTE / SANITARY VENT STANDARDS EW-330 EMERGENCY EYEWASH BRADLEY S19274HDB SWING-DOWN BRASS CHROME PLATED 1/2" 1/2"ADA COMPLIANT F1-330 DOMESTIC WATER FAUCET WATERSAVER L412VB-BH MIXING, GOOSENECK BRASS CHROME PLATED 1/2" 1/2" 1-1/2" 1-1/2" ADA COMPLIANT F2-330 QUALITY WATER FAUCET WATERSAVER L7833 POLYPROPYLENE LINED, 6" RISER BRASS CHROME PLATED 1/2"ADA COMPLIANT PIPING ACCESSORIES SCHEDULE AND SPECIFICATIONS TAG DEVICE BOD MANUFACTURER MODEL CAPACITY SPECIFICATIONS G-1 TUBE FITTING (N2/CA/VAC) SWAGELOK SS-400-1-4 N/A STAINLESS STEEL, MALE CONNECTOR, WITH 1/4" TUBE OD END AND 1/4" MALE NPT END PRV1-330 PRESSURE REGULATING ASSEMBLY WATERSAVER L3173-366-758WS 300 PSIG INLET HORIZONTAL ASSEMBLY, BRASS BODY WITH NEOPRENE DIAPHRAGM, 0-125 PSIG OUTLET RANGE, REMOVABLE QUICK CONNECT FITTING. PRV2-330 PRESSURE REGULATING ASSEMBLY WATERSAVER L2873-366V-758WS 300 PSIG WOG VERTICAL ASSEMBLY, BRASS BODY WITH NEOPRENE DIAPHRAGM, 0-125 PSIG OUTLET RANGE, REMOVABLE QUICK CONNECT FITTING. V-1 SHUT-OFF BALL VALVE(WATER/AIR SERVICE) WATTS B6000-SS 300 PSIG WOG MSS SP-110, 2-PIECE, STANDARD PORT, BRONZE BODY, 316 SS BALL & STEM, PTFE OR TFE SEAT V-2 SHUT-OFF BALL VALVE (N2) SWAGELOK SS-45S8 2500 PSIG STAINLESS STEEL, 1-PIECE, 1/2" SWAGELOK TUBE FITTING ENDS. V-3 SHUT-OFF BALL VALVE (RODI) HAYWARD TB SERIES 125 PSIG ASTM D1784, MSS SP-122, UNION TYPE WITH SOCKET ENDS PLUMBING GENERAL NOTES 1.0 DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED IN THE CONTRACT. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. IF DIMENSIONS OR CONDITIONS ARE FOUND TO BE IN CONFLICT WITH THE DRAWINGS, THE CONTRACTOR SHALL IMMEDIATELY REFER THE CONFLICT TO THE ENGINEER. 2.0 UTILITY SHUTDOWNS: SHUTDOWN OF ANY BUILDING UTILITY SYSTEM SHALL BE COORDINATED WITH CUSTOMER SERVICE AT PH: 607-255-5322. THE CONTRACTOR SHALL BEAR THE COST OF THE UTILITY SHUTDOWN. SCHEDULE WORK TEN DAYS IN ADVANCE AND NOTIFY THE OWNER'S REPRESENTATIVE TO COORDINATE BUILDING FUNCTIONS WITH THE BUILDING COORDINATOR. 3.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE WORK OF OTHER TRADES (EG ELECTRICAL, MECHANICAL). ALTHOUGH NOT NECESSARILY SHOWN ON DRAWINGS, WORK IS REQUIRED IN THESE AREAS CONSISTING OF REMOVAL / REPLACEMENT OF CEILINGS, WALLS, FINISHES, PAVEMENT AND OTHER CONSTRUCTION AS NECESSARY TO PERFORM WORK AND RESTORE THESE SPACES OR AREAS TO ORIGINAL CONDITION. 4.0 ALL PENETRATIONS THROUGH FULL HEIGHT WALLS ARE TO BE FIRESTOPPED IN ACCORDANCE WITH UL STANDARDS. ALL GAPS AND JOINTS AT RATED FLOORS, ROOFS AND WALLS ARE TO BE FIRE AND SMOKE STOPPED. CAPS AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND CONTROL OR EXPANSION JOINTS. FIRESTOPPING INCLUDES BOTH FORM OR PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. 5.0 INSTALL EQUIPMENT TO ENSURE PROPER ACCESS TO CONTROL DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. EQUIPMENT THAT IS NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. 6.0 ALL SYSTEM TESTING SHALL BE CONDUCTED PRIOR TO INSULATION, FIREPROOFING, AND ENCLOSURE IN SHAFTS. ANY RESTORATION WORK REQUIRED AS A RESULT OF DISTURBING FINISHES OR STRUCTURE IN ORDER TO ACCESS SYSTEMS REQUIRING REPAIR SHALL BE AT NO COST TO THE UNIVERSITY. 7.0 VERIFY FINAL EQUIPMENT/FIXTURE LOCATIONS FOR ROUGHING-IN. 8.0 ANY FIRESTOPPING DISTURBED DURING THE COURSE OF WORK SHALL BE REPAIRED TO MAINTAIN A 2-HOUR FIRE RATING. 9.0 THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY TO FORM A COMPLETE, FUNCTIONING SYSTEM. ITEMS NOT SPECIFICALLY MENTIONED, BUT WHICH ARE INHERENTLY NECESSARY TO MAKE A COMPLETE WORKING INSTALLATION SHALL BE PROVIDED. PLUMBING PIPING SCHEDULE AND SPECIFICATIONS PIPE SERVICE ABBREVIATION MATERIAL FITTINGS JOINT INSULATION THICKNESS (IN) CONDUCTIVITY (BTU-IN/HR-FT^2-DEGF) MEAN TEMP (DEG F)MATERIAL DOMESTIC COLD WATER DCW ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER, LEAD FREE 1 0.22-0.27 75 TYPE A DOMESTIC HOT WATER DHW ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER, LEAD FREE 1 0.22-0.27 75 TYPE A NITROGEN N2 ASTM A269 316L STAINLESS STEEL ASTM A162 316L STAINLESS STEEL COMPRESSION N/A N/A N/A N/A LAB WASTE & VENT LW/LV ASTM D4101 ASTM D635 POLYPROPYLENE, SCH 40 ASTM A162 316L STAINLESS STEEL COMPRESSION N/A N/A N/A N/A COMPRESSED AIR CA ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER, LEAD FREE N/A N/A N/A N/A REVERSE OSMOSIS DEIONIZED WATER RODI ASTM F441, CPVC, SCH 80 ASTM F439 SOCKET TYPE SOCKET N/A N/A N/A N/A VACUUM VAC ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER, LEAD FREE N/A N/A N/A N/A 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% CD REVIEW 3 09/4/2020 ISSUE FOR CONSTRUCTION 1 2 3 1/2" N2 1 1/4" TW 3/4" VAC 1 1/4" RODI 1 1/4" RODI1/2" N2 1/2" CA 1/2" DCW 1/2" DHW 3 330 4 5 5 2" LV 1 1/4" TW 3/4" VAC 1 1/4" RODI1 1/4" RODI 1/2" N2 1/2" CA 1/2" DCW 1/2" DHW 1/2" N2 3/4" VAC 1/2" CA 4 5 7 7 7 VAC N2 CA CW RODI VAC VAC N2 CA 330 8 3/4" VAC1/2" N21/2" CA91 1/4" RODI1 1/4" RODI10 1/2" CA 1/2" N2 3/4" VAC 3/4" VAC 1/2" N2 1/2" CA 4 1/2" DCW2" LV (E) 11 P-101 4 10 REFER TO ADA FUME HOOD ELEVATION 3/M-101 FOR PLUMBING TO FUME HOOD REFER TO 5/P-101 FOR RODI PIPING CONTINUATION 6 P-101 PRV2-330 PRV2-330 V-1 N2 CA VAC PRV2-330 PRV2-330 V-1 N2 CA VAC PRV2-330 PRV2-330 V-1 N2 CA 11 3 M-101 234 4" LW (E) 4" LW (E) 1-1/2" LW RISER TO THIRD FLOOR FUME HOOD CUP SINK 12 3 2 F1-330 F2-330 EW-330 1 1/2" CA (E) RODI FAUCET LAB SINK FAUCET EYEWASH 1-1/4" TW (E) 1/2" CW (E) 1-1/4" RODI 6 1/2" DWH (E) 13 FUME HOOD LAB SINK 10 1-1/4" BUILDING RODI LOOP (E) 1-1/4" BUILDING RODI LOOP EXTEND 1-1/4" BUILDING RODI LOOP TO FUME HOOD VALVE AND CAP REMOVED 1/2" RODI LOOP PIPING AT MAINS 10 V-3 V-3 V-3 3/4" VAC1/2" N21/2" CAPRV1-330 V1 E9 MILL UTILITY SERVICE RACK (E) CENTER ISLAND/ MOVABLE TABLES DROP CEILING (E) 5 PROVIDE SPLIT-RING ESCUTCHEON AT PIPING PENETRATIONS THROUGH CEILING (TYP FOR 3) MOUNT PIPING TO EXISTING SERVICE RACK FRAME (TYP FOR 3) TERMINATE PIPING SERVICES WITH SWAGELOK 1/4" FITTING FOR CONNECTION BY OTHERS (TYP FOR 3) V1 V2 CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 343 CAMPUS ROAD ITHACA, NEW YORK 14850 DUFFIELD HALL 330 LAB RENOVATIONS P-101 12672500 PARTIAL SECOND AND THIRD FLOOR PLUMBING FLOOR PLANS E. LEPORE TRF 2000 SEPTEMBER 4, 2020 SCALE:1/4" = 1'-0"1 PARTIAL THIRD FLOOR PLUMBING DEMOLITION PLAN SCALE:1/4" = 1'-0"2 PARTIAL THIRD FLOOR PLUMBING CONSTRUCTION PLAN P-101 KEYED DEMOLITION NOTES 1 DISCONNECT DCW, DHW, AND TEPID WATER AT LAB SINK TO SUPPORT RECONNECTING AN ADA HEIGHT SINK. REMOVE EXISTING 1/2" RODI PIPING AND REFER TO RENOVATION NOTES FOR RODI SUPPLY TO FAUCET F2-330. 2 DISCONNECT 1-1/2" LAB WASTE AND TRAP TO SUPPORT RECONNECTING AN ADA HEIGHT SINK. 3 CUT AND PATCH WALL AS REQUIRED TO REMOVE 1/2" COMPRESSED AIR. PATCH WALL TO MATCH EXISTING. 4 REMOVE 1/2" NITROGEN DROP ON WALL. RETAIN ISOLATION VALVE AND HOLD ON SITE FOR REUSE. 5 DISCONNECT AND REMOVE EXISTING 1/2" RODI LOOP IN UTILITY CORRIDOR. VALVE AND CAP PIPING AT MAINS. PATCH WALL TO MAINTAIN EXISTING 2 HOUR FIRE RATING. P-101 KEYED RENOVATION NOTES 1 1/2" COMPRESSED AIR - CAP AND SEAL. 2 RECONNECT EXISTING 1/2" DCW AND 1/2" DHW TO ADA SINK FAUCET F1-330. RECONNECT EXISTING 1/2" TEPID WATER TO EYEWASH EW-300. 3 RECONNECT LAB SINK DRAIN TO EXISTING LAB WASTE SYSTEM WITH 1-1/2" DRUM TRAP. 4 CONNECT TO EXISTING 1/2" COMPRESSED AIR AND 3/4" VACUUM. 5 UTILITY RACK GAS MANIFOLD. REFER TO ELEVATION 6/P-101. 6 PROVIDE AND INSTALL ADA FAUCET, QUALITY WATER FAUCET AND SURFACE MOUNT EYE-WASH. SINK BY OTHERS. REFER TO P-001 PLUMBING FIXTURE SCHEDULE. 7 DROP LAB GAS SERVICES TO WORK SURFACE. INSTALL PRESSURE REGULATOR ASSEMBLY ON COMPRESSED AIR AND NITROGEN SERVICES. TERMINATE VACUUM, COMPRESSED AIR, AND NITROGEN SERVICES WITH 1/4" SWAGELOK CONNECTIONS. FINAL CONNECTION TO EQUIPMENT BY OTHERS. 8 OFFSET EXISTING 1/2" NITROGEN OVER TO LOCATION SHOWN. REINSTALL ISOLATION VALVE, PROVIDE REGULATOR ASSEMBLY, AND TERMINATE WITH 1/4" SWAGELOK CONNECTOR AT WORK SURFACE. 9 CONNECT LAB GAS AND WATER SERVICES TO ADA FUME HOOD WITH FLEXIBLE CONNECTIONS CAPABLE OF ADJUSTABLE HEIGHT HOOD FULL RANGE OF MOTION. 10 EXTEND 1-1/4" RO/DI LOOP AND 1/2" DCW TO NEW FUME HOOD. PROVIDE FLEXIBLE CONNECTION CAPABLE OF ADJUSTABLE HEIGHT HOOD FULL RANGE OF MOTION. REFER TO 5/P-101 FOR RODI PIPING SCHEMATIC. 11 PROVIDE 1-1/2" LAB WASTE CONNECTION TO HOOD CUP SINK. PROVIDE DRUM TRAP AND ADJUSTABLE HEIGHT TAILPIECE. CONNECT 1-1/2" LAB VENT AND DROP 1-1/2" LAB WASTE DOWN THROUGH FLOOR WITH 2-HOUR RATED PENETRATION SYSTEM. CUP SINK AND HOOD BY OTHERS. REFER TO DETAIL 3/M-101. 12 CONNECT 1-1/2" CUP SINK DRAIN TO EXISTING 4" LAB WASTE PIPING ABOVE SECOND FLOOR CEILING. CORE DRILL OPENING THROUGH THIRD FLOOR SLAB AS REQUIRED TO ROUTE PIPING TO SECOND FLOOR. FIRESTOP PIPING PENETRATION TO MAINTAIN FLOOR RATING. FIELD VERIFY PENETRATION LOCATION AND COORDINATE WITH EXISTING STRUCTURE/UTILITES. CONTRACTOR RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF EXISTING CEILING TILES. PROVIDE AND INSTALL NEW TILES THAT BECOME DAMAGED. PROVIDE TEMPORARY PROTECTION FROM DUST AND DAMAGE TO THE LAB SPACE AND EQUIPMENT BELOW. COORDINATE WITH FACILITY MANAGER AND 234 LAB MANAGER PRIOR TO COMMENCEMENT WORK. 13 PROVIDE 1-1/4" RODI LOOP DROP ALONG WALL. PROVIDE 1/2" RODI SUPPLY TO QUALITY WATER FAUCET F2-330. ROUTE PIPING THROUGH CABINET/SINK COUNTERTOP TO AS REQUIRED TO ROUTE PIPING TO FAUCET. # # 0' 2' 4' 8' SCALE: 1/4"=1'-0" SCALE:1/4" = 1'-0"3 PARTIAL SECOND FLOOR PLUMBING CONSTRUCTION PLAN 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% CD REVIEW 3 09/4/2020 ISSUE FOR CONSTRUCTION SCALE:1/2" = 1'-0"4 ADA LAB SINK LAYOUT NOT TO SCALE5RODI WATER PIPING SCHEMATIC DETAIL 0' 1' 2' 4' SCALE: 1/2"=1'-0" SCALE:1/2" = 1'-0"6 LAB SERVICE CONNECTIONS ELEVATION CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 343 CAMPUS ROAD ITHACA, NEW YORK 14850 DUFFIELD HALL 330 LAB RENOVATIONS M-001 12672500 GENERAL NOTES AND SYMBOL LEGENDS E. LEPORE TRF 2000 SEPTEMBER 4, 2020 MECHANICAL ABBREVIATIONS BCU BLOWER COIL UNIT CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY CC CLEAN CONDENSATE CO CLEAN OUT CS CLEAN STEAM CD CONDENSATE DRAIN EA EXHAUST AIR EAG EXHAUST AIR GRILLE FD FIRE DAMPER GWR GLYCOL HEATING RETURN GWS GLYCOL HEATING SUPPLY HPR HIGH PRESSURE STEAM RETURN HPS HIGH PRESSURE STEAM SUPPLY HWR HOT WATER HEATING RETURN HWS HOT WATER HEATING SUPPLY LPC LOW PRESSURE CONDENSATE LPS LOW PRESSURE STEAM MU MAKE UP WATER MPC MEDIUM PRESSURE CONDENSATE MPS MEDIUM PRESSURE STEAM NG NATURAL GAS PCWR PROCESS CHILLED WATER RETURN PCWS PROCESS CHILLED WATER SUPPLY HG REFRIGERANT HOT GAS RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION RAG RETURN AIR GRILLE SA SUPPLY AIR SAD SUPPLY AIR DIFFUSER VD VOLUME DAMPER MECHANICAL SYMBOLOGY AIRFLOW BACKFLOW PREVENTER BALANCE VALVE BALL VALVE BOTTOM PIPE CONNECTION BUTTERFLY VALVE CAP OR PLUG CHECK VALVE CIRCULATING PUMP DIRECTION OF FLOW DUCT AIRFLOW DUCT DOWN (EXHAUST OR RETURN) DUCT DOWN (SUPPLY) FIRE AND SMOKE DAMPER IN DUCT FIRE DAMPER IN DUCT FLANGE CONNECTION FLEX CONNECTOR FLEXIBLE CONNECTION FLEXIBLE DUCT FLOW METER FLOW SWITCH FUSIBLE LINK VALVE GLOBE VALVE MANUAL AIRVENT ORIFICE METER PIPE DOWN PIPE UP PIPING REDUCER (CONCENTRIC) PIPING REDUCER (ECCENTRIC) PRESSURE GAUGE PRESSURE OR TEMPERATURE PETES PLUG PRESSURE REDUCING VALVE PRESSURE SWITCH RECTANGULAR ELBOW RECTANGULAR ELBOW WITH TURNING VANES RELIEF VALVE SMOKE DAMPER IN DUCT SOLENOID VALVE STANDARD BRANCH DUCT STEAM TRAP STRAINER (DUPLEX) STRAINER WITH BLOWDOWN VALVE AND CAP SUPPLY THROUGH NEXT FLOOR OR ROOF TEMPERATURE WELL THERMOMETER THERMOMETER (DIAL) TOP PIPE CONNECTION TRIPLE DUTY VALVE UNION CONNECTION VACUUM BREAKER VOLUME DAMPER IN DUCT CONTROL SYMBOLOGY 2-WAY CONTROL VALVE, DIGITAL 2-WAY CONTROL VALVE, PNEUMATIC 3-WAY CONTROL VALVE, DIGITAL 3-WAY CONTROL VALVE, PNEUMATIC ADDRESSABLE OUTPUT MODULE (FIRE ALARM INTERFACE) AIRFLOW CONTROL VALVE (VENTURI OR VORTEX SHEDDING) AVERAGING SENSOR BINARY POINT BUTTERFLY CONTROL DAMPER CARBON DIOXIDE SENSOR CONDENSATE SENSOR CURRENT SENSOR DEW-POINT SENSOR DIFFERENTIAL PRESSURE SENSOR DIFFERENTIAL PRESSURE SENSOR ELECTRIC TO PNEUMATIC SWITCH ELECTRIC TO PNEUMATIC TRANSDUCER END SWITCH FLOW ELEMENT (METER) FLOW SENSOR HIGH LEVEL SWITCH HUMIDSTAT SENSOR LIQUID IMERSION TEMPERATURE SENSOR LOW LEVEL SWITCH MODULATING MOTOR MOTOR STARTER NETWORK COMMUNICATION POINT, BACnet MSTP OCCUPANCY SENSOR OPEN/CLOSE OPPOSED BLADE CONTROL DAMPER PARALLEL BLADE CONTROL DAMPER PNEUMATIC THERMOSTAT PRESSURE SENSOR PRESSURE SWITCH RELATIVE HUMIDITY SENSOR RELAY ROOM TEMPERATURE SENSOR WITH ADJUSTABLE THERMOSTAT ROOM TEMPERATURE SENSOR WITH OCCUPANCY OVERRIDE ROOM TEMPERATURE SENSOR WITH ON/OFF SWITCH ROOM TEMPERATURE SENSOR WITH VISUAL DISPLAY ROTATION DETECTOR SINGLE POINT SENSOR SMOKE DETECTOR SPEED COMMAND START/STOP STATIC PRESSURE SENSOR SWITCH TEMPERATURE SENSOR TEMPERATURE SENSOR TEMPERATURE SENSOR WITH ADJUSTABLE SETPOINT GENERAL DRAWING SYMBOLOGY DEMOLISHED WORK EXISTING PIPING TO REMAIN EXISTING TO REMAIN EXISTING WORK TO REMAIN NEW WORK POINT OF CONNECTION POINT OF DISCONNECTION CONTROL ABBREVIATIONS AI ANALOG INPUT AO ANALOG OUTPUT AV ANALOG VALUE BI BINARY INPUT BO BINARY OUTPUT BV BINARY VALUE F.L. FAIL LAST N.C. NORMALLY CLOSED N.O. NORMALLY OPEN VFD VARIABLE FREQUENCY DRIVE MECHANICAL SCOPE OF WORK 1.0 PROVIDE VENTILATION SYSTEM (SUPPLY AND EXHAUST) UPGRADES AS REQUIRED TO ACCOMODATE PROPOSED RESEARCH FOR THE DUFFIELD 330 CIRA LAB. 2.0 INTEGRATE VENTILATION CONTROLS INTO THE EXISTING BUILDING MANAGEMENT SYSTEM. 3.0 PROVIDE AN ADA FUME HOOD. 4.0 PROVIDE PROCESS EXHAUST FOR INDIVIDUAL RESEARCH EQUIPMENT. 5.0 SELECTIVE DEMOLITION OF EXISTING SUPPLY AND EXHAUST DISTRIBUTION SYSTEMS TO ACCOMODATE UPGRADES. MECHANICAL GENERAL NOTES 1.0 ALL DUCT DIMENSIONS INDICATED ARE IN INCHES, AND ARE INSIDE FREE AND CLEAR DIMENSIONS. 2.0 PNEUMATIC TERMINATIONS: IF COPPER: DEMO BACK TO MAIN AND PROVIDED SOLDERED END CAP IF POLY: DEMO BACK TO MAIN AND PROVIDE BRASS PLUG DO NOT USE SHEETMETAL SCREW OR BEND OVER END OF COPPER TUBE. 3.0 INSTALL EQUIPMENT TO ENSURE PROPER ACCESS TO CONTROL DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. EQUIPMENT THAT IS NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. 4.0 ALL SYSTEM TESTING SHALL BE CONDUCTED PRIOR TO INSULATION, FIREPROOFING, AND ENCLOSURE IN SHAFTS. ANY RESTORATION WORK REQUIRED AS A RESULT OF DISTURBING FINISHES OR STRUCTURE IN ORDER TO ACCESS SYSTEMS REQUIRING REPAIR SHALL BE AT NO COST TO THE UNIVERSITY. 5.0 CUTTING AND PATCHING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING, AND PATCHING TO COMPLETE THE WORK. WHERE EXISTING CONSTRUCTION IS REMOVED, CAUSING AN EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES, RESULTING SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. 6.0 ANY FIRESTOPPING DISTURBED DURING THE COURSE OF WORK SHALL BE REPAIRED TO MAINTAIN A 2-HOUR FIRE RATING. 7.0 TESTING AND BALANCING: THE CONTRACTOR SHALL BALANCE ALL AIR SYSTEMS AS INDICATED. SUBMIT RESULTS OF TESTING AND BALANCING ON STANDARD TAB CONTRACTOR'S FORMS TO THE ENGINEER FOR REVIEW. SYSTEMS SHALL BE BALANCED TO WITHIN +/- 10% OF DESIGN VALUES. FINAL BALANCING SHALL OCCUR AFTER ALL LEAKS IN THE BUILDING ENVELOPE HAVE BEEN IDENTIFIED AND SEALED. 8.0 SEAL ALL PIPE, GRILLE, DIFFUSER, DUCT, CONDUIT PENETRATIONS WITH APPROPRIATE MATERIALS (CAULK, FOAM, ETC,) THAT ARE IMPENETRABLE TO THE CONTAINED ORGANISMS AND WITHSTAND REPEATED DECONTAMINATIONS WITH CLEANING AGENTS. MECHANICAL SUBMITTAL SCHEDULE SECTION TITLE REQUIRED 230000 HEATING, VENTILATING & AIR-CONDITIONING - 230517 SLEEVES AND SLEEVE SEALS FOR HVAC PIPING PRODUCT DATA 230518 ESCUTCHEON FOR HVAC PIPING PRODUCT DATA 230523 GENERAL DUTY VALVES FOR HVAC PIPING PRODUCT DATA 230529 HANGERS & SUPPORTS FOR HVAC PRODUCT DATA 230553 IDENTIFICATION FOR HVAC COMPONENTS PRODUCT DATA 230593 TESTING, ADJUSTING & BALANCING FOR HVAC QUALIFICATIONS, INSPECTION AND TEST REPORTS 230700 HVAC INSULATION PRODUCT DATA 230719 HVAC PIPING & EQUIPMENT INSULATION PRODUCT DATA 230900 INSTRUMENTATION & CONTROL FOR HVAC PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 230920 ANALOG LABORATORY CONTROL PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 230923 DIRECT DIGITAL CONTROL SYSTEM FOR HVAC PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 230924 AUTOMATION & CONTROL SYSTEM PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 232113 HYDRONIC PIPING PRODUCT DATA 233113 METAL DUCTS PRODUCT DATA 233116 NONMETAL DUCTS PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 233300 AIR DUCT ACCESSORIES PRODUCT DATA 233600 AIR TERMINAL UNITS PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 233700 AIR OUTLETS AND INLETS PRODUCT DATA 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% CD REVIEW 3 09/4/2020 ISSUE FOR CONSTRUCTION 1 1 1 2 2 2 2 2 24x8 EA 48x18 EA42x1812x12 SA DUCT MAIN ABOVE CORRIDOR CEILING (E) EA DUCT MAIN IN UTILITY CORRIDOR (E) EG-330 (E) SD1-330 (E) SD2-330 (E) SD3-330 (E) SD4-330 (E)3 VAV-53 (D) VAV-54 (D) ROOM TS (E) 2 1" HWS 1" HWR 330 EAV-330-1 4' ADA FUME HOOD EAV-330-2 24x8 EA(E)48x18 EA(E)1344 CFM 1130 CFM 1 130 CFM 2 25 CFM 25 CFM 4 150 CFM 8ø EA3ø EA3ø EA6ø EA10ø EA 12ø EA6495 CFM 16x12 EA 20x16 EA 10ø EA EAV-330-3 742x1818x14 SAV-330-1 RHC-330 8 9 14 9 E8 LASER CUTTER E4 VACUUM PUMP 2 E3 VACUUM PUMP 1 E11 ELECTROSPINNING STATION E12 3D PRINTER E9 MILL 350 CFM 8ø 10x68ø 8ø10 11 EAV-330-4 912x8 VD VD 12 13 328 CFM 13 328 CFM 13 328 CFM 5 136 CFM SD5-330 SD1-330 (E) SD2-330 (E) SD3-330 (E) SD4-330 (E) 15 329 CFM 16 10ø8øVD VD VD 18x14 10 10 12 3 M-101 6ø EA VD 10ø 6ø 26 ROOM TS (E) 3 1" HWS 1" HWR 2 M-501 2 MANUAL VENTILATION SHUTOFF SWITCH 27 16ø 8ø 28 200 CFM VD VD 24x8 29 30100 CFM 10ø 6ø 6øVD 3RD FLOOR 34' -0" PENTHOUSE LEVEL 50' -0" 3RD FLOOR 34' -0" VAC N2 CA 17 ADA FUME HOOD 18 19 20 21 22 23 25 241 1/2" LV1/2" DCW1 1/4" RODI1 1/4" RODI1/2" CA1/2" N23/4" VAC10ø8ø 1-1/2" LW4" LW (E) DCW RODI COORDINATION NOTE: HOOD (PROVIDED BY OTHERS) TO BE PROVIDED WITH INTERNAL PLUMBING, VALVES, AND FIXTURES FROM THE FACTORY MEETING SPECIFICATIONS AS OUTLINED ON THE PLUMBING PLANS. INTERNAL PLUMBING TO INCLUDE THE FOLLOWING: -VAC -N2 WITH HOOD MOUNTED REGULATOR ASSEMBLY -CA WITH HOOD MOUNTED REGULATOR ASSEMBLY -DCW WITH VACUUM BREAKER AND GOOSENECK TO CUPSINK -RODI WITH VACUUM BREAKER AND GOOSENECK TO CUPSINK 28 CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 343 CAMPUS ROAD ITHACA, NEW YORK 14850 DUFFIELD HALL 330 LAB RENOVATIONS M-101 12672500 PARTIAL THIRD FLOOR MECHANICAL FLOOR PLANS E. LEPORE TRF 2000 SEPTEMBER 4, 2020 # 0' 2' 4' 8' SCALE: 1/4"=1'-0" M-101 KEYED DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING GENERAL EXHAUST AIR VALVE AND ASSOCIATED ACCESSORIES. REMOVE PORTION OF EXHAUST DUCTWORK TO PREPARE FOR RECONNECTION. 2 REMOVE EXISTING SUPPLY AIR VALVE, REHEAT COIL PIPING, REHEAT COIL CONTROL VALVE, ASSOCIATED ACCESSORIES, AND PORTION OF SUPPLY AIR DUCTWORK AS REQUIRED FOR THE RENOVATIONS. 3 DISCONNECT AND RETAIN EXISTING SUPPLY AIR DIFFUSER. HOLD ON SITE FOR REINSTALLATION. #M-101 KEYED RENOVATION NOTES 1 PROCESS EXHAUST DROP DOWN TO EXHAUST ENCLOSURE. PROVIDE BLAST GATE DAMPER AND BALANCE TO AIRFLOW SPECIFIED. ENCLOSURE PROVIDED BY OTHERS. 2 3" DUCT DROP TO VACUUM PUMP. TERMINATE 12" ABOVE COUNTER SURFACE. PROVIDE BLAST GATE DAMPER AND BALANCE TO 25 CFM. 3 CONNECT TO EXISTING REHEAT HOT WATER PIPING AND EXTEND 3/4" HOT WATER SUPPLY AND HOT WATER RETURN TO REHEAT COIL. PROVIDE PIPING PER DETAIL AND BALANCE FLOW PER SCHEDULE. 4 6" EXHAUST DUCT DROP TO SNORKEL ARM WITH 14" SNORKEL HOOD. BASIS OF DESIGN - MONOXIVENT MODEL MNX-CDH-100. SERVES 3D PRINTER AND FINISHING STATION. PROVIDE WITH BLAST GATE DAMPER. REFER TO DETAIL 2/M-501. 5 SOLDERING IRON. LOCATION SHOWN FOR TEMPORARY STORAGE. WHEN IN USE, SOLDERING PROCESS TO BE PERFORMED INSIDE ONE OF THE EXHAUSTED ENCLOSURES OR THE FUME HOOD. 6 10" DIA EXHAUST DROP DOWN TO ADA FUME HOOD. PROVIDE BLAST GATE DAMPER. CONNECT TO HOOD WITH FLEXIBLE METAL DUCT. REFER TO DETAIL 3/M-101. FUME HOOD PROVIDED BY OTHERS 7 PROVIDE 8"DIA RIGID METAL DUCT ALONG WALL DOWN TO LASER. PROVIDE FLEX DUCT CONNECTION AT LASER. 3 FOOT MAX LENGTH OF FLEX. 8 PROVIDE SUPPLY AIR VALVE AND REHEAT COIL. CONNECT DIGITAL CONTROL TO BMS. 9 PROVIDE EXHAUST AIR VALVE. CONNECT DIGITAL CONTROL TO BMS. 10 FIRE STOP DUCT PENETRATION TO MATCH EXISTING CORRIDOR WALL RATING. 11 FUME FILTER/FAN COMBINATION - FUMEX MODEL FA5. FUME FILTER/FAN BY OTHERS. MECHANICAL CONTRACTOR TO PROVIDE DUCT AND CONTROL CONNECTIONS. PROVIDE FLEX DUCT CONNECTIONS AT THE FUME FILTER/FAN 3' MAX LENGTH FLEX ON INLET AND OUTLET. POWER BY ELECTRICAL CONTRACTOR. 12 EXHAUSTED ENCLOSURE PROVIDED BY OWNER. PROVIDE GLYCOL SMOKE TEST. AFTER APPROVED TESTING AND BALANCING OF THE PROCESS EXHAUST, CONTACT EHS, MECHANICAL ENGINEER, BALANCER AND CONTROLS CONTRACTOR WITH TWO WEEKS NOTICE TO SCHEDULE A GLYCOL SMOKE TEST OF THE EXHAUSTED ENCLOSURE TO VERIFY THE CAPTURE VELOCITY. PROVIDE VIDEO DOCUMENTING OF GLYCOL SMOKE TEST. UNSATISFACTORY TESTING WILL REQUIRE REBALANCING OF THE ENCLOSURE AT THE TIME OF TESTING. INCREASE EXHAUST AIRFLOW AND CAPTURE VELOCITY AS NECESSAR FOR A SATISFACTORY TEST. SIGN-OFF BY EHS AND ENGINEER IS REQUIRED AT THE CONCLUSION OF THIS TEST. 13 REBALANCE EXISTING CEILING SUPPLY DIFFUSER TO 328 CFM. 14 PROVIDE NEW FUME HOOD EXHAUST AIR VALVE AND CONNECT TO EXISTING BUILDING AUTOMATION AND CONTROL SYSTEM. PROVIDE FUME HOOD CONTROLLER AND SASH POSITION SENSORS. 15 REINSTALL EXISTING CEILING SUPPLY DIFFUSER. PROVIDE WITH MANUAL BALANCING DAMPER AND BALANCE TO AIRFLOW SHOWN. 16 TRANSITION TO RECTANGULAR NECK DIFFUSER. MODULAR CORE, 2-WAY DIFFUSER. ADJUST CORE FOR AIR PATTERN SHOWN. 17 REFER TO ARCHITECTURAL DRAWINGS FOR ADA ACCESSIBLE FUME HOOD AND ADJUSTABLE BASE. 18 FUME HOOD WORK SURFACE SHALL BE 36-INCHES ABOVE FINISH FLOOR FOR NON-ADA HEIGHT AND 30-INCHES ABOVE FINISH FLOOR FOR ADA HEIGHT. 19 PROVIDE 1-1/2" DRUM TRAP. PROVIDE SUFFICIENT PIPE ON INLET TO ALLOW 6" OF WORKSURFACE ADJUSMENT. 20 PROVIDE 1-1/4" DRAIN FROM CUP SINK. PROVIDE SUFFICIENT TAILPIECEON OUTLET TO ALLOW FOR 6" OF WORK SURFACE ADJUSTMENT. DRAIN IS TO BE SLEEVED WITHIN THE 1-1/2" INLET PIPE PROVIDED ON THE DRUM TRAP. 21 CONNECT 1-1/2" DRAIN TO LAB WASTE PIPING ABOVE SECOND FLOOR CEILING. CORE DRILL OPENING THROUGH THIRD FLOOR SLAB AS REQUIRED TO ROUTE PIPING TO SECOND FLOOR. PROVIDE 2-HR RATED PENETRATION SYSTEM. FIELD VERIFY PENETRATION LOCATION AND COORDINATE WITH EXISTING STRUCTURE/UTILITES. CUP SINK AND HOOD BY OTHERS. 22 PROVIDE 1-1/4" VENT SERVING CUP SINK DRAIN. ROUTE PIPING ALONG WALL ADJACENT TO FUME HOOD AND CONNECT TO EXISTING 2" LAB VENT PIPING ABOVE CEILING. 23 COORDINATE INSTALLATION OF DUCT WITH SUSPENDED LAY-IN ACOUSTICAL CEILING SYSTEM. PROVIDE OPENING THROUGH TILE/GRID SUFFICIENT FOR THE ROUNE ROUND DUCTWORK PENETRATION. 24 FLEXIBLE EXHAUST DUCT SHALL BE FLEXHAUST BENDWAY-PLUS OR EQUAL, 316Ti STAINLESS STEEL, 10-INCH ROUND NOMINAL DIMENSION. 25 FUME HOOD LAB SERVICES CONNECTIONS. PROVIDE STAINLESS STEEL FLEXIBLE CONNECTIONS TP PRE-PIPED 26 PROVIDE DUCT ACCESS DOOR AT REHEAT COIL FOR INSPECTION AND MAINTENANCE. 27 PROVIDE MANUAL VENTILATION SHUTOFF SWITCH, BASIS OF DESIGN PILLA ELECTRICAL ST120. SWITCH SHALL BE LABELED "VENTILATION SYSTEM EMERGENCY SHUTOFF". CONNECT TO CONTROLS OF ALL SUPPLY AND EXHAUST AIR VALVES SERVING 330. CONTROL CONTRACTOR TO PROVIDE LOW VOLTAGE CONTROL WIRE ALONG WALL SURFACE INSIDE ROOM 330. SURFACE RACEWAY SHALL BE WIREMOLD 700. FIRESTOP CONDUIT PENETRATION IN WALL AND MAINTAIN WALL RATING. 28 DROP 8" DIA EXHAUST AIR DUCT DOWN TO FLOOR. TERMINATE 12" AFF WITH 1/2" ALUMINUM MESH. BALANCE TO 200 CFM WITH GENERAL EXHAUST VALVE IS SET TO MAX FLOW PER AIRFLOW SCHEDULE. 29 CONTROL CONTRACTOR TO PROVIDE THE LASER POWER RELAY CAT. NO. RIBU1C AT LOCATION SHOWN. COORDINATE WITH THE ELECTRICAL CONTRACTOR TO RUN NEAREST 120V POWER TO THE DEVICE. LOW VOLTAGE WIRING BY THE CONTROL CONTRACTOR. SURFACE REACEWAY FOR THE 120V POWER SHALL BE A WIREMOLD 700. 30 DROP 6" DIA SUPPLY AIR DUCT DOWN TO FLOOR. TERMINATE 12" AFF WITH 1/2" ALUMINUM MESH. BALANCE TO 100 CFM WHEN SUPPLY VALVE IS SET TO MAX FLOW PER AIRFLOW SCHEDULE. SCALE:1/4" = 1'-0"1 PARTIAL THIRD FLOOR HVAC DEMOLITION PLAN SCALE:1/4" = 1'-0"2 PARTIAL THIRD FLOOR HVAC CONSTRUCTION PLAN SCALE:1/2" = 1'-0"3 ADA FUME HOOD ELEVATION 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% CD REVIEW 3 09/4/2020 ISSUE FOR CONSTRUCTION 0' 1' 2' 4' SCALE: 1/2"=1'-0" N.C. F AI FLOW AO MOD AO COMMAND T AI REHEAT COILSAV-330 VERTICAL SASH POSITION SENSOR 4' FUME HOOD FUME HOOD MONITOR EAV-330-1 FLOW AIAO COMMAND SEQUENCE OF OPERATION SYSTEM DESCRIPTION EXISTING: GENERAL EXHAUST AIR VALVE (VAV-53) SUPPLY AIR VALVE (VAV-54) DUCT MOUNTED RE-HEAT COIL ROOM TEMPERATURE SENSOR ROOM OCCUPANCY SENSOR EMERGENCY PURGE TO BE PROVIDED: FUME HOOD EXHAUST AIR VALVE (EAV-330-1) GENERAL EXHAUST AIR VALVE (EAV-330-2) PROCESS EXHAUST AIR VALVE (EAV-330-3) LASER EXHAUST AIR VALVE (EAV-330-4) SUPPLY AIR VALVE (SAV-330) REHEAT COIL CONTROL VALVE (CV-330-RH) GENERAL ANY REFERENCE TO "HOOD" OR "FUME HOOD" IN THIS SEQUENCE OF OPERATIONS REFERS TO THE 4' ADA FUME HOOD AND NOT TO BE CONFUSED WITH THE (3) EXHAUSTED ENCLOSURES THAT ARE CONNECTED TO THE PROCESS EXHAUST VALVE (EAV-330-3) ALL SETPOINTS SHALL BE ADJUSTABLE. LABORATORY AIR CHANGE RATES ARE BASED ON TOTAL EXHAUST AIR FLOW FROM THE SPACE. THIS LABORATORY IS CURRENTLY SERVED BY AN EXISTING AUTOMATED LOGIC CONTROL SYSTEM. EXISTING POINTS ARE TO BE RE-UTILIZED FOR THE NEW SEQUENCE OF OPERATION WHERE FEASIBLE. THE BASIS OF DESIGN MAXIMUM AIRFLOWS ARE DESIGNED TO MAINTAIN A 100 FPM FACE VELOCITY AT THE FUME HOOD. HOWEVER, IT MAY BE POSSIBLE TO OPERATE THE FUME HOOD WITH A FACE VELOCITY OF 80 FPM. THIS WILL BE DETERMINED AT THE TIME OF FUME HOOD CERTIFICATION. THE BACS CONTRACTOR WILL BE RESPONSIBLE FOR BEING ON-SITE DURING FUME HOOD CERTIFICATION, AND RE-PROGRAM AS NEEDED TO RESET THE AIRFLOW SETPOINTS BASED ON THE CERTIFICATION PROCESS. SETPOINTS SPACE TEMPERATURE SETPOINTS: OCCUPIED:WINTER 70 °F, SUMMER 75°F +/-1.5 °F OCCUPIED SETBACK:WINTER 70 °F, SUMMER 75°F +/-3 °F UNOCCUPIED:WINTER 70 °F, SUMMER 75°F +/-6 °F AIRFLOW SETPOINTS ARE DETAILED IN THE AIRFLOW SCHEDULE, SEE M-501. LABORATORY AIRFLOW CONTROL AIR VALVE POSITIONS SHALL BE BASED ON MODE. UNDER NORMAL CONTROL, ROOM OCCUPANCY SHALL BE DETERMINED VIA ROOM OCCUPANCY SENSORS. WHEN THE ROOM IS OCCUPIED, THE BACS SHALL SEND AN OCCUPIED COMMAND TO THE FUME HOOD MONITOR. THE FUME HOOD EXHAUST AIR VALVE SHALL MODULATE BETWEEN THE MINIMUM AND MAXIMUM POSITIONS AS NEEDED TO MAINTAIN THE FACE VELOCITY SETPOINT BASED ON THE SASH POSITION. THE SUPPLY AIR VALVE, SAV-330 AND THE PROCESS EXHAUST VALVE, VAV-330-3 SHALL MAINTAIN CONSTANT VOLUME WITH A 745 CFM DIFFERENTIAL BETWEEN THE TWO AT ALL TIMES. THE GENERAL EXHAUST VALVE, EAV-330-2, SHALL MODULATE AS NEEDED TO MAINTAIN THE SPACE AT 100 CFM NEGATIVE. WHEN THE ROOM IS UNOCCUPIED, AND THE SASHES ARE AT OR BELOW 18-INCHES, THE BACS SHALL SEND AN UNOCCUPIED COMMAND TO THE FUME HOOD MONITORS. THE FUME HOOD EXHAUST AIR VALVES SHALL MODULATE BETWEEN MINIMUM AND MAXIMUM UNOCCUPIED POSITIONS AS NEEDED TO MAINTAIN A 65 FPM FACE VELOCITY SETPOINT BASED ON THE SASH POSITION. THE GENERAL EXHAUST VALVE, EAV-330-2, SHALL MODULATE AS NEEDED TO MAINTAIN THE SPACE AT 100 CFM NEGATIVE. WHEN THE ROOM IS UNOCCUPIED AND THE FUME HOOD SASH IS ABOVE 18-INCHES, THE BACS SHALL NOT SEND THE SPACE UNOCCUPIED COMMAND TO THE FUME HOOD EXHAUST AIR VALVE. WHEN THE FUME HOOD EXHAUST AIR VALVE SASH IS ABOVE 18- INCHES IT SHALL MAINTAIN THE OCCUPIED SASH OPEN AIRFLOW SETPOINT. THE BACS WILL SEND THE UNOCCUPIED COMMAND TO THE FUME HOOD WHEN THE SASH IS AT OR BELOW 18-INCHES AND THE FUME HOOD EXHAUST AIR VALVE SHALL MODULATE TO MAINTAIN A 65 FPM FACE VELOCITY SETPOINT. THE SUPPLY AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE SPACE AT 100 CM NEGATIVE. LASER EXHAUST AIRFLOW CONTROL LAB USER SHALL ENGAGE AND DISENGAGE POWER TO THE LASER WITH THE MANUAL WALL SWITCH. WHEN THE BACS DETECTS THE LASER IS ENGAGED, THE LASER EXHAUST VALVE (VAV-330-4) SHALL OPEN AND THE LASER FAN UNIT SHALL RECEIVE A LOW VOLTAGE SIGNAL FROM THE BACS TO THE REMOTE ON/OFF INTERFACE PROVIDED WITH THE FAN UNIT THAT WILL ENGAGE THE LASER FAN. THE LASER FAN WILL PROVE FLOW AND SEND A SIGNAL TO THE BACS TO ENGAGE POWER TO THE LASER. WHEN THE LASER IS ENGAGED, THE LASER EXHAUST VALVE IS OPEN AND THE LASER FAN IS ENGAGED. WHEN THE LASER IS NOT ENGAGED, THE LASER EXHAUST VALVE IS CLOSED AND THE FAN REMAINS DISENGAGED. IF THE LASER FAN DOES NOT PROVE FLOW, THE POWER TO THE LASER DOES NOT ENGAGE. WHEN THE VENTILATION SHUT-OFF SWITCH IS ENGAGED, THE POWER TO THE LASER IS DISENGAGED, THE LASER FAN DISENGAGES AND VAV-330-4 CLOSES. LASER EXHAUST VALVE SHALL MAINTAIN A CONSTANT VOLUME EXHAUST OF 350 CFM WHEN THE LASER AND FAN ARE ENGAGED AND THE GENERAL EXHAUST VALVE SHALL MODULATE TO MAINTAIN THE ROOM WITH A NEGATIVE DIFFERENTIAL. ZONE TEMPERATURE CONTROL TEMPERATURE SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF PROGRAMMED SCHEDULE AND SPACE OCCUPANCY SENSORS. OCCUPIED HEATING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT, THE SUPPLY AIR REHEAT CONTROL VALVE (CV-330-RH) SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. WHEN THE SPACE TEMPERATURE IS AT SETPOINT, THE BASEBOARD RADIATION AND REHEAT COIL CONTROL VALVES SHALL BE CLOSED. OCCUPIED SETBACK: IF THE SPACE BECOMES UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE ABOVE OCCUPIED HEATING SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE MAINTAINED AT THE OCCUPIED SETBACK TEMPERATURE SETPOINT. UNOCCUPIED HEATING: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE SUPPLY AIR REHEAT COIL CONTROL VALVE (CV-330-RH) SHALL MODULATE AS REQUIRED TO MAINTAIN SETPOINT. COOLING: THERE ARE NO COOLING MODE SEQUENCES REQUIRED FOR THIS SPACE. LAB VENTILATION SHUTOFF CONTROL THE LAB VENTILATION SHUTOFF CONTROL SWITCH IS MOUNTED OUTSIDE OF THE 330 LAB NEXT TO THE DOOR AS SHOWN ON PLAN. WHEN THIS SWITCH IS ENGAGED, ALL SUPPLY AND EXHAUST AIR VALVES THAT SERVE LAB 330 SHUT CLOSED AND THE LASER FAN AND THE POWER TO THE LASER IS DISENGAGED. AN ALARM SHALL BE GENERATED AT THE USER WORKSTATION. RESET OF THE AIRFLOW, LASER FAN AND LASER POWER TO NORMAL OPERATION SHALL BE MANUALLY ENGAGED AT THE USER WORKSTATION. LAB 330 AI AI (FACE VELOCITY) BI (ALARM) BO (HOOD SETBACK COMMAND) EAV-330-3 FLOW AIAO COMMAND EAV-330-2 FLOW AIAO COMMAND LASER (BY OTHERS)EAV-330-4FLOW AI AO COMMAND LASER EXHAUST FAN (BY OTHERS) SERVICE CORRIDOR 336 BO ON/OFF BI PROOF OF FLOW BUILDING PROCESS EXHAUST (E)BUILDING SUPPLY AIR (E)FROM AHU-1 TO EF-5/6 CV-330-RH1 LAB VENTILATION SHUTOFF SWITCH S BI S BI MANUAL LAB PURGE BUTTON (E) OS BI OS BI LAB OCCUPANCY SENSOR (330 CURTAIN AREA) LAB OCCUPANCY SENSOR (E) SETPOINT (E) AV T AI sa d PROVIDED WITH REMOTE ON/OFF S BI MANUAL LASER POWER ON/OFF SWITCH S SR BO LASER POWER RELAY AI HORIZONTAL SASH POSITION SENSOR CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 343 CAMPUS ROAD ITHACA, NEW YORK 14850 DUFFIELD HALL 330 LAB RENOVATIONS M-401 12672500 CONTROLS E. LEPORE TRF 2000 SEPTEMBER 4, 2020 NOT TO SCALE1BUILDING AUTOMATION AND CONTROL SYSTEM 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% CD REVIEW 3 09/4/2020 ISSUE FOR CONSTRUCTION CONTROL AND ALARM POINTS SCHEDULE LAB 105 HARDWARE POINTS SOFTWARE POINTS SHOW ON GRAPHIC NOTESBI BO AI AO AV BV SCH TREND ALARM BACS EMCS DESCRIPTION CV-105-RH, COIL VALVE POSITION COMMAND (%)X X 5 DEG F DELTA T ACROSS COIL WITH VALVE COMMANDED CLOSED USE EXISTING POINT EAV-330-1, AIRFLOW (CFM)X X X SERVES NEW EXHAUST VALVE FOR FUME HOOD EAV-330-1, AIRFLOW SETPOINT (CFM)X X SERVES NEW EXHAUST VALVE FOR FUME HOOD EAV-330-1, FUME HOOD UNOCC COMMAND X X SERVES NEW EXHAUST VALVE FOR FUME HOOD EAV-330-1, VALVE POSITION COMMAND (CFM)X X SERVES NEW EXHAUST VALVE FOR FUME HOOD EAV-330-2, AIRFLOW (CFM)X X X USE EXISTING POINT EAV-330-2, AIRFLOW SETPOINT (CFM)X X 10% DEVIATION FROM SETPOINT X USE EXISTING POINT EAV-330-2, VALVE POSTION COMMAND (CFM)X X USE EXISTING POINT EAV-330-3, AIRFLOW (CFM)X X X SERVES NEW PROCESS EXHAUST VALVE EAV-330-3, AIRFLOW SETPOINT (CFM)X X SERVES NEW PROCESS EXHAUST VALVE EAV-330-3, VALVE POSITION COMMAND (CFM)X X 10% DEVIATION FROM SETPOINT SERVES NEW PROCESS EXHAUST VALVE EAV-330-4, AIRFLOW (CFM)X X X SERVES NEW LASER EXHAUST VALVE EAV-330-4, AIRFLOW SETPOINT (CFM)X X SERVES NEW LASER EXHAUST VALVE EAV-330-4, VALVE POSITION COMMAND (CFM)X X SERVES NEW LASER EXHAUST VALVE LAB 330 FUME HOOD SASH POSITION X X X SASH OPEN (18") FOR 24 CONTINUOUS HOURS OR MORE X LAB 330 FUME HOOD STATUS (ALARM)X X X LOW FACE VELOCITY X LAB 330 FUME HOOD VELOCITY (FPM)X X LAB OCCUPANCY SENSOR (330 CURTAIN AREA)X LAB OCCUPANCY SENSOR (330)X USE EXISTING POINT LAB VENTILATION SHUTOFF SWITCH X X X LASER EXHAUST FAN FLOW SWITCH X X X X LASER EXHAUST FAN REMOTE ON/OFF X X X LASER ON/OFF SWITCH X X LASER POWER RELAY ON/OFF CONTROL X X SAV-330, AIRFLOW (CFM)X X X USE EXISTING POINT SAV-330, AIRFLOW SETPOINT (CFM)X X USE EXISTING POINT SAV-330, REHEAT COIL DISCHARGE AIR TEMP X X USE EXISTING POINT SAV-330, VALVE POSITION COMMAND (CFM)X X USE EXISTING POINT SUPPLY RETURN ISOLATION VALVE (TYP. OF 2) BALANCING VALVE PRESSURE/TEMPERATURE TEST PORT (TYP. OF 2) MANUAL AIR VENT COIL CV-330-RH 3RD FLOOR 34' -0" 3RD FLOOR 34' -0" 6" EA ON WALL 4" CONNECTION WALL MOUNTING BRACKET 4" LOCAL EXHAUST EXTRACTION ARM. BASIS OF DESIGN - MONOXIVENT MODEL MHX-CDH-100 WALL (E) LAB BENCH (E) CEILING (E) 14" DOME HOOD EXTRACTION ARM COORDINATION: OFFSET LOCATION OF WALL BRACKET AND EXTRACTION ARM MOUNTING AS RECOMMENDED BY THE MANUFACTURER AND AS NECESSARY FOR PROPER REACH OF THE HOOD TO THE 3D PRINTER AND FINISHING STATION.CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 343 CAMPUS ROAD ITHACA, NEW YORK 14850 DUFFIELD HALL 330 LAB RENOVATIONS M-501 12672500 SCHEDULES AND DETAILS E. LEPORE TRF 2000 SEPTEMBER 4, 2020 DUCT SCHEDULE AND SPECIFICATIONS SERVICE PRESSURE CLASS SEAL CLASS LEAKAGE CLASS DUCT MATERIAL LINING DUCT INSULATION SUPPLY, RECTANGULAR, EXPOSED, AHU - VAV (EXPOSED IN UTILITY CORRIDOR) 4" POS A 6 G90 GALVANIZED NONE MIN R-6, TYPE B, WITH VAPOR RETARDER, PAINT SUPPLY, RECTANGULAR, CONCEALED (ABOVE DROP CEILING)4" POS A 6 G90 GALVANIZED NONE MIN R-6, TYPE A WITH VAPOR RETARDER SUPPLY, RECTANGULAR, CONCEALED, TERMINAL UNIT - OUTLET 2" POS A 6 G90 GALVANIZED NONE MIN R-6, TYPE A WITH VAPOR RETARDER SUPPLY, ROUND, CONCEALED, TERMINAL UNIT - OUTLET 2" POS A 3 G90 GALVANIZED NONE MIN R-6, TYPE A WITH VAPOR RETARDER EXHAUST: LABORATORY - ACCESSIBLE LOCATIONS AND RISERS 4" NEG A RECT 6/ROUND 3 316 STAINLESS STEEL, WELDED NONE N/A EXHAUST: FUME HOOD - CONNECTION OF DUCT TO MAIN 4" NEG A RECT 6/ROUND 3 316 STAINLESS STEEL, WELDED NONE N/A AIRFLOW SCHEDULE LAB ROOM DIMENSIONS EXHAUST AIR SUPPLY POINT OCC SASH OPEN (100 FPM) OCC SASH OPEN (80 FPM) OCC SASH CLOSED UNOCC SASH FULL UNOCC SASH OPEN UNOCC SASH CLOSED ALL MODESAREA (SF) HEIGHT (FT) EXHAUST POINT VALVE OCC SASH OPEN (100 FPM) OCC SASH OPEN (80 FPM) OCC SASH CLOSED OCC LASER OFF UNOCC SASH FULL UNOCC SASH OPEN UNOCC SASH CLOSED 330 536 10 4' ADA FUME HOOD EAV-330-1 495 CFM 396 CFM 140 CFM 140 CFM 495 CFM 322 CFM 140 CFM SAV-330 1549 CFM 1549 CFM 1549 CFM 747 CFM 574 CFM 574 CFM -200 CFM GENERAL EXHAUST EAV-330-2 100 CFM 200 CFM 455 CFM 805 CFM 50 CFM 50 CFM 50 CFM PROCESS EXHAUST EAV-330-3 804 CFM 804 CFM 804 CFM 804 CFM 402 CFM 402 CFM 402 CFM LASER EXHAUST EAV-330-4 350 CFM 350 CFM 350 CFM 0 CFM 0 CFM 0 CFM 0 CFM TOTAL LAB 1749 CFM 1749 CFM 1749 CFM 1749 CFM 947 CFM 774 CFM 774 CFM CONTROL VALVE SCHEDULE & SPEC TAG BOD MANF BOD VALVE MODEL SERVICE VALVE TYPE VALVE SIZE (IN)CV ACTUATOR MODEL CONTROL CAPACITY (GPM)PD (PSIG) FAIL POS CV-330-RH1 BELIMO CCV - B213 RHC-330-1 2-WAY 1/2 1.9 TR24-SR-T US MOD 2.2 1.3 F.L. 1. ACCEPTABLE MANUFACTURERS: BELIMO, VSI 2. ELECTRIC INPUT: 4-20mA OR 0-10VDC 3. 2-WAY VALVES: EQUAL PERCENTAGE FLOW CHARACTERISTIC 4. CONSTRUCTION: CHARACTERIZING DISK, FORGED BRASS, NICKEL PLATED BODY, STAINLESS STEEL BALL AND STEM, FIBERGLASS REINFORCED PTFE SEAT 5. RATINGS: 400 PSI PRESSURE, 0-212 F MEDIA TEMPERATURE RANGE 6. ALL CONTROL WIRING SHALL BE INSTALLED IN CONDUIT. 7. CONTROL WIRING SHALL BE UNSPLICED FROM THE CONTROLLER TO THE SENSOR OR DEVICE. 8. CONTROL WIRING SHALL NOT BE ROUTED IN THE SAME RACEWAY AS POWER WIRING. 9. CONTROL WIRING SHALL BE COLOR CODED AND LABELED AT ALL POINTS OF TERMINATION. 10. TEST EACH POINT THROUGH IT FULL OPERATING RANGE TO VERIFY THAT SAFETY AND OPERATING CONTROL SET POINTS ARE AS REQUIRED. 11. TEST EACH CONTROL LOOP TO VERIFY STABLE MODE OF OPERATION AND COMPLIANCE WITH SEQUENCE OF OPERATION. ADJUST PID ACTIONS AS REQUIRED. 12. THE BACS CONTRACTOR SHALL ISSUE A REPORT UPON PROJECT COMPLETION STATING THAT THE SYSTEM IS COMPLETE, HAS BEEN ADJUSTED, AND HAS HAD ALL HARDWARE AND SOFTWARE FUNCTIONS VERIFIED, THAT ALL ANALOG CONTROL LOOPS ARE TUNED, AND IS OPERATING IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. ANY DEVIATIONS FROM SPECIFIED SETTINGS OR OPERATIONS NECESSITATED DURING SYSTEM ADJUSTMENT SHALL BE SPECIFICALLY NOTED. AIR VALVE SCHEDULE & SPECS TAG # SERVES SUP EXH BASIS OF DESIGN SIZE DESIGN CFM ΔPT @ MAX DESIGN CFM REHEAT COIL TAG DAMPER POSITIONMANF MODEL MAX MIN EAV-330-1 330 LAB - FUME HOOD X ACCUVALVE AVC6308-05-WS 8" 495 140 0.6 N.O. EAV-330-2 330 LAB - GENERAL EXH X ACCUVALVE AVC6310-05-WS 10" 805 50 0.6 N.O. EAV-330-3 330 LAB - PROCESS X ACCUVALVE AVC6310-05-WS 10" 804 402 0.6 N.O. SAV-330-1 330 LAB - SUPPLY AIR X ACCUVALVE AVC6414-05-IWS 14" 1549 574 0.6 RHC-330 N.C. EAV-330-4 330 LAB - LASER X ACCUVALVE AVC6408-05-WS 8" 350 80 0.6 N.O. 1. THE AIRFLOW DEVICES SHALL BE CALIBRATED AT THE FACTORY TO THE FULL RANGE OF RECOMMENDED AIRFLOWS. ACTUAL AIRFLOWS WILL BE SET IN SOFTWARE. 2. SETPOINTS REPRESENT FUME HOOD FACE VELOCITY AT 100 FPM. FINAL SETPOINTS WILL BE ADJUSTED IF FACE VELOCITIES ARE REDUCED TO 80 FPM AS A RESULT OF FUME HOOD TESTING AND CERTIFICATION. 3. ACCEPTABLE MANUFACTURERS: ACCUTROL 4. CONFIGURATION: PRESSURE INDEPENDENT. 5. SUPPLY VALVE BODY: 16GA ALUMINUM, INSULATED. 6. HOOD EXHAUST VALVE BODY: 20 GA 316 STAINLESS STEEL. 7. INSTALLATION: LEVEL AND PLUMB, PER NFPA 90A, SMACNA DUCT CONSTRUCTION STANDARDS, AND MANUFACTURERS RECOMMENCED INSTRUCTIONS. 8. PROVIDE ALL VALVES WITH TIGHT SHUT-OFF OPTION. 1. ALL DUCTWORK AND ACCESSORIES SHALL BE FABRICATED AND INSTALLED IN COMPLIANCE WITH THE LATEST ISSUE OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE. 2. CONSTRUCT TEES, BENDS, AND ELBOWS WITH RADIUS OF NOT LESS THAN 1.0 TIMES THE WIDTH OF DUCT ON CENTER LINES. 3. WHERE RECTANGULAR ELBOWS ARE USED, PROVIDE AIR FOIL TYPE TURNING VANES 4. INCREASE DUCT SIZES GRADUALLY, AND IN COMPLIANCE WITH FIGURE 4-7 OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE. 5. BRANCH CONNECTIONS SHALL BE MADE WITH A 45 DEGREE ENTRY. STRAIGHT TEES ARE NOT ACCEPTABLE. 6. SEALANTS AND GASKETS: SURFACE BURNING CHARACTERISTICS SHALL BE A MAXIMUM FLAME-SPREAD INDEX OF 25, AND MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED TO UL 723. 7. ALL MANUAL BALANCING DAMPERS SHALL BE PROVIDED WITH LOCKING HAND QUADRANT. 8. ACCESS DOORS SHALL MATCH DUCT MATERIAL WITH INSULATION FILL AND THICKNESS AS INDICATED FOR DUCT PRESSURE CLASS. 9. ACCESS DOORS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: BOTH SIDES OF DUCT COILS IN ORDER TO RESET OR REINSTALL FUSIBLE LINKS, AND AS INDICATED. 10. INSTALL VOLUME DAMPERS AT POINTS ON SUPPLY AND EXHAUST SYSTEMS WHERE BRANCHES EXTEND FROM LARGER DUCTS. 11. PAINT ALL DUCTWORK EXPOSED TO VIEW IN OCCUPIED AREAS TO MATCH SURROUNDING FINISH. 12. REMOVE SURFACE CONTAMINANTS AND DEPOSITS FROM DUCTWORK AND EQUIPMENT PRIOR TO TESTING AND BALANCING. 13. LEAK TESTING OF DUCTWORK SHALL BE IN ACCORDANCE WITH SMACNA'S HVAC AIR DUCT LEAKAGE TEST MANUAL. 14. ALL DUCTS DESIGNED TO OPERATE AT STATIC PRESSURES IN EXCESS OF 3-INCHES WG (POS OR NEG) SHALL BE TESTED. TEST SHALL BE WITNESSED BY A DESIGNATED CORNELL REPRESENTATIVE AND THE PROJECT ENGINEER OF RECORD. 25% OF DUCTS DESIGNED TO OPERATE AT STATIC PRESSURES 3-INCHES AND BELOW SHALL BE TESTED. ACCEPTANCE CRITERIA: INTERIOR SUPPLY, RETURN AND GENERAL EXHAUST: 5% SYSTEM LEAKAGE TESTED AT 1.25 TIMES THE EXPECTED OPERATING STATIC PRESSURE. ACCEPTANCE CRITERIA: INTERIOR LABORATORY EXHAUST SYSTEMS: 2% SYSTEM LEAKAGE TESTED AT 1.25 TIMES THE EXPECTED OPERATING STATIC PRESSURE. AN AIR DUCT LEAKAGE TEST SUMMARY SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO FINAL PROJECT ACCEPTANCE. 15. ALL INSULATION AND ADHESIVE SHALL HAVE A MAXIMUM FLAME-SPREAD INDEX OF 25 AND A MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84. 16. INSULATION TYPE A: MINERAL FIBERGLASS BLANKET, ASTM C553 TYPE I, ASTM C1136 TYPE I FACTORY APPLIED FSK JACKET, K-VALUE BETWEEN 0.22 -0.29 BTU-IN/HR-FT²-˚F @ 75 ˚F, 0.75 PCF 1. COORDINATE WITH CORNELL EH&S DURING FUME HOOD TESTING AND CERTIFICATION. REDUCTION IN THE FUME HOOD FACE VELOCITY TO 80 FPM MAY BE POSSIBLE. HVAC PIPE AND FITTING SCHEDULE AND SPECIFICATIONS PIPE SERVICE ABBREVIATION PIPE SIZE MATERIAL FITTINGS JOINT INSULATION HEATING HOT WATER HWS&R 1-1/2" & BELOW ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER 1", TYPE A WITH VAPOR RETARDER GRILLE SCHEDULE MARK SERVES MANUFACTURER (BOD) MODEL (BOD) TYPE AIRFLOW DUCT SIZE SPECIFICATIONS SD4-330 (E) LAB 330 EXISTING EXISTING EXISTING 329 CFM 10ø EXISTING SD5-330 LAB 330 KRUEGER SERIES 51240 MODULAR CORE 136 CFM 6ø 24"X24" PANEL SIZE, 8"X8" NECK, ALUMINUM WITH WHITE FINISH 1. ACCEPTABLE MANUFACTURERS: ANEMOSTAT, CARNES, KRUEGER, PRICE, TITUS. REHEAT COIL SCHEDULE TAG COIL SIZE WxH (IN)ROWS TOTAL CAPACITY (BTUH) AIR SIDE WATER SIDE FLOW RATE (CFM) ENT AIR TEMP (˚F) LVG AIR TEMP (˚F) AIR PRESSURE DROP (IN WC) FOW RATE (GPM) ENT WATER TEMP (˚F) LVG WATER TEMP(˚F) WATER PRESSURE DROP (FT WC) RHC-330 24x12 2 33,458 1549 55 75 0.55 2.2 130 100 3.0 1. ACCEPTABLE MANUFACTURERS: GREENHECK, ANEMOSTAT, KRUEGER, NAILOR, TITUS, TRANE, PRICE TO COORDINATE WITH AIR TERMINAL BOX. 2. RATINGS: ARI 410, INDUSTRY STANDARD FOR FORCED CIRCULATION AIR COOLING AND AIR HEATING COILS 3. 1/2-IN COPPER TUBING WITH MECHANICALLY BONDED ALUMINUM FINS. 4. SUPPLY PIPING TO COIL TO BE PIPED WITH SHUT OFF VALVE, STRAINER, CONTROL VALVE AND UNION. 5. RETURN PIPING TO COIL TO BE PIPED WITH SHUT-OFF VALVE, BALANCING VALVE, AND UNION. 6. COIL SHALL BE PIPED IN COUNTERFLOW ARRANGEMENT. 7. PIPING SHALL BE ARRANGED TO ALLOW SERVICE AND MAINTENANCE. NOT TO SCALE1REHEAT COIL PIPING DETAIL 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% CD REVIEW 3 09/4/2020 ISSUE FOR CONSTRUCTION SCALE:1/2" = 1'-0"2 EXTRACTION ARM DETAIL CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 343 CAMPUS ROAD ITHACA, NEW YORK 14850 DUFFIELD HALL 330 LAB RENOVATIONS E-001 12672500 GENERAL NOTES AND SYMBOL LEGENDS H. TRAN JD 2000 SEPTEMBER 4, 2020 ELECTRICAL SUBMITTAL SCHEDULE MATERIAL SCHEDULE/ SHOP DWGS. PRODUCT DATA SAMPLES INSPECTIONS & TESTS O&M DATA WARRANTIES LUMINAIRE X LIGHT SWITCHES X GENERAL ELECTRICAL NOTES 1.0 ELECTRICAL SCHEMATICS INDICATED ON CONTRACT DOCUMENTS ARE DIAGRAMMATIC. IT IS NOT THE INTENT TO SHOW EXACT OR MOST EFFICIENT ROUTING. VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ON SITE. ANY CONFLICTS BETWEEN CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALL BE BROUGHT TO CORNELL'S PROJECT MANAGER FOR RESOLUTION BEFORE WORK PROCEEDS. 2.0 ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOINING AREAS FROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE AND DISPOSE OF WASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISES FREE OF DEBRIS FROM THE EXECUTION OF WORK. DELIVER A FINAL PRODUCT THAT IS CLEAN AND OPERABLE. 3.0 FIRE STOP ELECTRICAL PENETRATIONS THROUGH FIRE RATED WALLS AND/OR FLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTION OF THE MATERIAL PENETRATED. 4.0 WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACT DOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHOD OF INSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FOR APPROVAL PRIOR TO ORDERING ANY MATERIALS OR COMMENCING EXECUTION OF WORK. 5.0 GROUNDING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 250. PROVIDE EQUIPMENT GROUND CONDUCTOR WITH EACH BRANCH CIRCUIT INDICATED ON CONTRACT DOCUMENTS. EQUIPMENT GROUND CONDUCTOR SHALL BE ROUTED WITH ASSOCIATED PHASE CONDUCTORS. 6.0 PROVIDE A NEW TYPED PANELBOARD DIRECTORY FOR EACH PANELBOARD. LABEL ALL NEW DEVICE FACEPLATES WITH SOURCE AND CIRCUIT NUMBER. PROVIDE PERMANENT LABEL ON SWITCHING DEVICES INDICATING EQUIPMENT SERVICE AND INVENTORY NUMBERS. COORDINATE EQUIPMENT INVENTORY NUMBERS WITH CORNELL UNIVERSITY'S MECHANICAL SHOP, 255-8667. 7.0 CIRCUITS RATED 20-AMP, 120 VOLT SHALL CONTAIN SEPARATE NEUTRAL CONDUCTORS. 8.0 CONDUCTORS SHALL BE A MINIMUM OF 12AWG, STRANDED COPPER, 600VAC, 90 DEGREE C, TYPE THHN/THWN-2 FOR DRY AREAS AND XHHW/THWN-2 FOR WET AREAS. 9.0 CONDUITS SHALL BE A MINIMUM OF 3/4 INCHES DIAMETER. CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT) AND SURFACE MOUNTED UNLESS NOTED OTHERWISE. 10.0 AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OF RESPECTIVE PANELBOARD. SIZE AS INDICATED. 11.0 PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDE SUPPORT HANGERS FOR CONDUIT AS NEEDED. 12.0 INSTALL RACEWAY SYSTEMS ENSURING PROPER ACCESS TO EQUIPMENT AND DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. RACEWAYS THAT ARE NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. ELECTRICAL SCOPE OF WORK 1.0 PROVIDE ELECTRICAL SUPPORT FOR THE RENIVATION OF 330 CIRCA LAB. ELECTRICAL LEGEND LIGHTING LEGEND MOTOR 1'x4' LUMINAIRE HARDWIRED EQUIPMENT CONNECTION P-1A 12 HOMERUN TO PANEL P-1A, CIRCUIT #12. FED FROM 20A -1P BREAKER IS INTENDED UNLESS NOTED OTHERWISE. RUN GREEN WIRE GROUND FOR ALL CIRCUITS. PROVIDE ONE GROUND PER CIRCUIT. EMERGENCY POWER OFF (EPO) GROUND ROD ELECTRODE DUPLEX RECEPTACLE WITH GFCI PROTECTION DUPLEX RECEPTACLE WITH AFCI PROTECTION QUAD RECEPTACLE LINETYPES LEGEND SPECIAL RECEPTACLE5-30R PANELBOARD JUNCTION BOX B = INSTALLED IN BASEBOARD TR = INSTALLED IN WOOD TRIM/CASEWORK/WAINSCOTT SR = SURFACE RACEWAY WP = WEATHERPROOF AC = AIR CONDITIONER DUPLEX RECEPTACLE: DOUBLE DUPLEX RECEPTACLE MOTOR STARTER J 2'x4' LUMINAIRE CEILING MOUNTED LUMINAIRE EM LIGHTING BATTERY UNIT COMBO EXIT SIGN/EM LIGHTING BATTERY UNIT SINGLE FACE, WALL MOUNT EXIT SIGN DOUBLE FACE, WALL MOUNT EXIT SIGN SINGLE FACE, CEILING MOUNT EXIT SIGN DOUBLE FACE, CEILING MOUNT EXIT SIGN LIGHT SWITCH: SAFETY SWITCH (NON-FUSED) SAFETY SWITCH (FUSED) 3 = 3-WAY SWITCH 4 = 4-WAY SWITCH D = DIMMER SWITCH O = WALL SWITCH OCCUPANCY SENSOR V = WALL SWITCH VACANCY SENSOR W = WIRELESS SWITCH S = WIRELESS SCENE SWITCH WIRELESS OCCUPANCY SENSOR WIRELESS DAYLIGHT SENSOR OS DS 1'x2' LUMINAIRE FIRE ALARM LEGEND FIRE ALARM CONTROL PANEL BATTERY CABINET WATER FLOW SWITCH MUXPAD REMOTE ANNUNCIATOR D = DUCT SMOKE DETECTOR R = RELAY BASE BR = BEAM RECEIVER BT = BEAM TRANSMITTER SB = SOUNDER BASE SMOKE DETECTOR: TAMPER SWITCH AUDIBLE NOTIFICATION APPLIANCE FACP BATT MUX FAA NAC PANELNAC MANUAL PULL STATIONF S X F = FIXED TEMPERATURE R = RATE OF RISE R/F = COMBINATION RISE/FIXED TEMPERATURE HEAT DETECTOR: H X CARBON MONOXIDE DETECTORCO AM F XXcd C FS F S XXcd C TS ADDRESSABLE MODULE XXcd = CANDELA C = CEILING COMBO A/V NOTIFICATION APPLIANCE: XXcd = CANDELA C = CEILING VISUAL NOTIFICATION APPLIANCE: SUPPRESSION SYSTEM ELECTRICAL ABBREVIATIONS AC AIR CONDITIONER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AFI ARC FAULT INTERRUPTER AMM ADDRESSABLE MONITOR MODULE AOM ADDRESSABLE OUTPUT MODULE ARB AUXILIARY RELAY BOARD ATS AUTOMATIC TRANSFER SWITCH B BASEBOARD BKR BREAKER C CONDUIT CD CANDELA CKT CIRCUIT CR CONTROL RELAY EC ELECTRICAL CONTRACTOR EMT ELECTRICAL METALLIC TUBING EPO EMERGENCY POWER OFF STATION FAA FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FSD FIRE SMOKE DAMPER GAA GENERATOR ALARM ANNUNCIATOR GFI GROUND FAULT INTERRUPTER GND GROUND HP HORSEPOWER KW KILOWATT LC LIGHTING CONTACTOR LFMC LIQUID TIGHT FLEXIBLE METALLIC CONDUIT LTG LIGHTING MCB MAIN CIRCUIT BREAKER MLO MAIN LUG ONLY MTS MANUAL TRANSFER SWITCH NAC NOTIFICATION APPLIANCE CIRCUIT NIC NOT IN CONTRACT OE OVERHEAD ELECTRIC PC PHOTOCELL PM PLUGMOLD PP POWER PANEL PVC POLYVINYL CHLORIDE CONDUIT RGS RIGID GALVANIZED STEEL CONDUIT SR SURFACE RACEWAY ST SHUNT TRIP TM THERMAL MAGNETIC TR TRIM/CASEWORK/WAINSCOTT TSP TWISTED SHIELDED PAIR TYP TYPICAL UE UNDERGROUND ELECTRIC UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY V VOLTS VA VOLT AMPS WP WATERPROOF UNDERGROUND ELECTRICU E UNDERGROUND LIGHTINGUL OVERHEAD ELECTRICO E TO BE PROVIDED DEMOLITION / TO BE RELOCATED EXISTING TO REMAIN UNDERGROUND TELCOU C MOUNTING HEIGHTS CARD READER 48" TOP OF BOX LIGHT SWITCH 48" TOP OF BOX RECEPTACLE 18" TOP OF BOX DATA OUTLET 18" TOP OF BOX TV OUTLET 84" TOP OF BOX PHONE OUTLET 48" TOP OF BOX SAFETY SWITCH 60" CENTERLINE OF HANDLE MOTOR STARTER 60" CENTERLINE OF HANDLE PANELBOARD 72" TOP OF PANELBOARD MANUAL PULL STATION 48" OPERABLE HANDLE NOTIFICATION APPLIANCE 80" BOTTOM OF LENS DOOR HOLD OPEN COORDINATE IN FIELD EM BATTERY UNIT 96" BOTTOM OF UNIT EM REMOTE UNIT 102" BOTTOM OF UNIT EXIT SIGN 96" BOTTOM OF UNIT LIGHT POLE WITH LED LUMINAIRES, REFER TO PLANS FOR NUMBER AND CONFIGURATION OF HEADS GENERAL ELECTRICAL DEMOLITION NOTES 1.0 ELECTRICAL EQUIPMENT SHOWN DASHED ON DEMOLITION DRAWINGS, INCLUDING ASSOCIATED ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS, AND OTHER APPURTENANCES NOT SHOWN, SHALL BE DISCONNECTED AND REMOVED. REMOVE ASSOCIATED BRANCH CIRCUITRY TO SOURCE, UNLESS NOTED OTHERWISE. 2.0 EXISTING RACEWAYS AND DEVICE BACKBOXES NOT INTERFERRING WITH NEW WORK SHALL BE REUSED WHERE POSSIBLE. 3.0 PROVIDE JUNCTION BOXES, RACEWAYS, AND WIRING TO MODIFY/EXTEND EXISTING SYSTEMS AND CIRCUITS FED DOWNSTREAM OF ELECTRICAL EQUIPMENT SHOWN TO BE DEMOLISHED. 4.0 CUT DEMOLISHED CONDUITS INSTALLED THRU WALLS AND FLOORS FLUSH WITH THE SURFACE AND PATCH PENETRATIONS (FIRESTOP IF LOCATED ON A FIRE RATED SURFACE). PATCH AND PAINT SURFACES IN EXPOSED AREAS TO MATCH SURROUNDING MATERIALS, FINISHES, AND COLORS. 5.0 PROVIDE BLANK COVERPLATES ON UNUSED BACKBOXES REMAINING FROM DEMOLITION NOT SPECIFIED TO BE INFILLED. 6.0 EXISTING EQUIPMENT SHOWN TO REMAIN SHALL BE PROTECTED DURING CONSTRUCTION. DATA/PHONE WIRELESS ACCESS POINTWL 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% REVIEW 3 09/04/2020 ISSUE FOR CONSTRUCTION 3 3 F330 2 1 OS OS S 330 4 3 330 (3) (3) (3) (3) (3) (3) (3)(3)(3) (3)(3) WIREMOLD 4000 WIREMOLD 4000 WIREMOLD 4000 EXISTING PHONE JACK EXISTING PANEL LPP-312, 208Y/120V EXISTING PENDANT POWER & DATA RACEWAY 1 2 5 6 GFCI GFCI GFCI GFCI CORNE LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 343 CAMPUS ROAD ITHACA, NEW YORK 14850 DUFFIELD HALL 330 LAB RENOVATIONS E-101 12672500 POWER, DATA, LIGHTING, AND FIRE ALARM PARTIAL THIRD FLOOR PLAN H. TRAN JD 2000 SEPTEMBER 4, 2020 # 0' 2' 4' 8' SCALE: 1/4"=1'-0" E-101 KEYED DEMOLITION NOTES 1 REMOVE LUMINAIRE AS INDICATED AND RETURN LUMINAIRE TO THE OWNER. MODIFIED EXISTING LIGHTING AS REQUIRED. 2 DURING CONSTRUCTION, PROVIDE A TEMPORARY HEAT DETECTOR IN THIS ROOM. SCALE:1/4" = 1'-0"1 PARTIAL THIRD FLOOR DEMOLITION SCALE:1/4" = 1'-0"2 PARTIAL THIRD FLOOR LIGHTING AND FIRE ALARM SCALE:1/4" = 1'-0"3 PARTIAL THIRD FLOOR POWER & DATA E-101 KEYED RENOVATION NOTES 1 AT 18" AFF TO TOP OF BOX, PROVIDE A SURFACE MOUNT RECEPTACLE. CIRCUIT THE RECEPTACLE TO THE NEW FUME HOOD CIRCUITRY. SURFACE RACEWAY SHALL BE WIREMOLD 700. 2 NEW ADA FUME HOOD BY OTHERS. ELECTRICAL CONTRACTOR TO PROVIDE POWER CONNECTION. CIRCUIT TO A SPARE 20A/1P CIRCUIT BREAKER LOCATED IN EXISTING PANEL LPP-312. CONDUIT CONNECTED TO THE FUME HOOD SHALL BE FLEXIBLE CONDUIT WITH (2) 12 AWG & (1) 12 AWG GROUND. 3 PROVIDE A NEW SURFACE MOUNT LIGHT SWITCH TO CONTROL THE TWO EXISTING LUMINAIRES LOCATED IN THE NEW CURTAIN. MODIFY THE EXISTING LIGHTING CIRCUIT AS REQUIRED. CIRCUIT THE LIGHTING SWITCH TO THE EXISTING LIGHTING CIRCUITRY. SURFACE RACEWAY ON WALL SHALL BE WIREMOLD 700. 4 THE CONTRACTOR TO PURCHASE A TOTAL OF 6 DARK AMBER UV BLOCKING TUBE GUARD W/ END CAPS CAT. NO. PLAS-T8UVA FROM 1000BULBS.COM. PROVIDE THE EXISTING LAMPS WITH THE TUBE GUARDS. 5 REPLACE EXISTING RECEPTACLES WITH NEW GFCI RECEPTACLES. 6 AT 18" AFF TO TOP OF BOX PROVIDE A NEW SURFACE MOUNT RECEPTACLE. CIRCUIT THE RECEPTACLE TO A SPARE 20A/1P CIRCUIT BREAKER LOCATED IN EXISTING PANEL LPP-312. PROVIDE (2) #12 AWG AND (1) #12 AWG GROUND IN 3/4" EMT AS REQUIRED. # 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% REVIEW 3 09/04/2020 ISSUE FOR CONSTRUCTION