HomeMy WebLinkAboutADD 1_Duffield 330 Lab Reno_10-6-2020CORNELL UNIVERSITY DUFFIELD HALL FACILITIES CONTRACTS 330 LAB RENOVATIONS 121 HUMPHREYS SERVICE BUILDING ITHACA, NEW YORK 14853-3701 ADDENDUM NO. 1 October 6, 2020 This Addendum contains changes to the requirements of the Contract Documents and Specifications. Such changes are to be incorporated into the Construction Documents and shall apply to the work with the same meaning and force as if they had been included in the original document. Wherever this Addendum modifies a portion of a paragraph of the specifications or a portion of any Drawing, the remainder of the Paragraph or Drawing shall remain in force. NOTE: Provisions of all Contract Documents apply. Item 1. ADD Section 01 21 00 – Allowances, attached. Item 2. ADD Section 01 23 00 – Alternates, attached. Item 3. Drawing A-101 ADD the following clarification to the end of Keyed Renovation Notes 5, 7, 10, 15, and 16: “Wood species to be maple. Door veneers to be Plain Sliced.” Item 4. Drawing A-101 DELETE Keyed Renovation Notes 17, 18, and 19 to remove scope from this project. The College of Engineering will purchase lab chairs/stools directly. Item 5. Drawing A-101, Keyed Renovation Note 20 DELETE in its entirety. REPLACE with: 20. In work area, inspect existing partitions up to deck, and floor penetrations to the floor below (second floor) and above (penthouse). Patch any larger openings with 5/8” gypsum drywall Type X, and use appropriate fire stopping material to fill any other open penetrations to confirm fire rating as indicated on code compliance plan A-001. Item 6. Drawing A-101, Door / Hardware Schedule ADD the following width to door 330-1: 3’-0” (active leaf) + 2’-0” Duffield Hall 330 Lab Renovations Addendum No. 1 October 6, 2020 Page 2 Item 7. Drawing P-001, Plumbing Piping Schedule and Specifications “Lab Waste and Vent” • DELETE Fittings information “ASTM A162 316L Stainless Steel” REPLACE with “ASTM D4101 POLYPROPYLENE” • DELETE Joint information “Compression” REPLACE with “Mechanical” Item 8. Drawing M-001, Mechanical General Notes ADD 8. Coordinate closely with the building manager and arrange for necessary system shut downs associated with connection to building central systems. Particularly, the central general exhaust system, exhaust fans EX-5 and EX-6. Item 9. DELETE drawing M-101 in its entirety. REPLACE with drawing M-101R1, attached. Item 10. DELETE drawing M-501 in its entirety. REPLACE with drawing M-501R1, attached. Item 11. DELETE drawing E-101 in its entirety. REPLACE with drawing E-101R1, attached. Item 12. RFI Questions and Clarifications See attached RFI Log (Items 1-2) Attachments: Section 01 21 00 Allowances Section 01 23 00 Alternates M-101R1 - Partial Third And Fourth Floor Mechanical Plans M-501R1 - Schedules And Details E-101R1 - Power, Data, Lighting, And Fire Alarm Partial Third Floor Plan RFI Log (Items 1-2) ****END OF ADDENDUM**** CORNELL UNIVERSITY SECTION 01 21 00 Ithaca, New York ALLOWANCES ADDENDUM NO. 1 ALLOWANCES 01 21 00-1 October 6, 2020 SECTION 01 21 00 ALLOWANCES 1.0 GENERAL 1.1 RELATED DOCUMENTS A. This Section describes Allowances to be carried in the Base Bid by the Contractor. B. Drawings and general provisions of the Contract, including General Conditions and other Division 01 Specification Sections, apply to this Section. C. The Specification Section containing the pertinent requirements of materials and methods to achieve the Work described herein. Selected materials and equipment are specified in the Contract Documents by allowances. 1.2 SUMMARY A. Definition: An allowance is an amount determined by the Owner or calculated by the Contractor based on given quantities and stated on the Bid Proposal Submission Form. B. Certain items are specified in the Contract Documents by allowances. Allowances have been established in lieu of additional requirements and to defer selection of actual materials and equipment to a later date when direction will be provided to the Contractor. Items covered by these allowances shall be supplied for such amounts and by such persons as the Owner may direct. All uses of the allowances will require the prior written approval of the Owner via a Field Change Authorization. C. Types of Allowances may include: 1. Lump Sum Allowance 2. Unit Price Allowance 1.3 SELECTION AND PURCHASE A. At the earliest practical date after award of the Contract, advise the Architect of the date when final selection and purchase of each product or system described by an allowance must be completed to avoid delaying the Work. The Contractor shall provide the Owner fourteen (14) calendar days minimum notification of date. B. At the Owner’s request, the Contractor shall obtain proposals for each allowance for use in making final selections. The Contractor shall include recommendations that are relevant to performing the work. C. The Contractor shall purchase products and systems selected by the Architect and Owner from the designated supplier. CORNELL UNIVERSITY SECTION 01 21 00 Ithaca, New York ALLOWANCES ADDENDUM NO. 1 ALLOWANCES 01 21 00-2 October 6, 2020 1.4 SUBMITTALS A. Submit proposals for purchase of products or systems included in allowances, in the form specified for Change Orders. B. Submit invoices or delivery slips to show actual quantities of materials delivered to the site for use in fulfillment of each allowance. C. Submit time sheets and other documentation to show labor hours and cost for installation of allowance items that include installation as part of the allowance. D. Coordinate and process submittals for allowance items in the same manner as for other portions of the work. 1.5 COORDINATION A. Coordinate related Work and modify or adjust adjacent Work as necessary to ensure that Work affected by each accepted allowance is complete and fully integrated into the Project. B. The Contractor shall include the dollar value of each scheduled allowance number as a separate line item in the Schedule of Values and identify each allowance with Section number 01 21 00. C. The Owner shall provide the Contractor with a Field Change Authorization prior to proceeding with the Work of an allowance. 1.6 LUMP SUM AND UNIT PRICE ALLOWANCES A. Allowances shall include cost to the Contractor of specific products and materials ordered by the Owner or selected by the Architect under allowance and shall include applicable taxes, freight, and delivery to the Project site. B. Included as part of each allowance are miscellaneous devices, accessory objects or similar items incidental to or required for a complete installation whether or not mentioned as part of the allowance. C. Unless otherwise indicated, Contractor’s cost for receiving and handling at Project site, labor, installation, overhead and profit, and similar costs related to products and materials ordered by the Owner or selected by the Architect under allowance shall be included as part of the Contract Sum and not part of the allowance. D. Unused Materials: Return unused materials purchased under an allowance to the manufacturer or supplier for credit to the Owner, after installation has been completed and accepted. 1. If requested by the Owner, retain and prepare unused materials for storage by the Owner. Deliver unused material to Owner’s storage space as directed. CORNELL UNIVERSITY SECTION 01 21 00 Ithaca, New York ALLOWANCES ADDENDUM NO. 1 ALLOWANCES 01 21 00-3 October 6, 2020 1.7 ADJUSTMENT OF ALLOWANCES A. Allowance Adjustment: To adjust allowance amounts and scope of work, prepare a Change Order proposal based on the difference between purchase amount and the allowance, multiplied by final measurement of work-in-place where applicable. If applicable, include reasonable allowances for cutting losses, tolerances, mixing wastes, normal product imperfections, and similar margins. 1. Include installation costs in purchase amount only where indicated as part of the allowance. 2. Prepare explanation and documentation to substantiate distribution of overhead costs and other margins claimed. 3. Submit substantiation of a change in scope of work, if any, claimed in Change Order related to unit-cost allowance. 4. Owner reserves the right to establish the quantity of work-in-place by independent quantity survey, measure, or count. B. Submit claims for increased costs because of a change in scope or nature of the allowance described in the Contract Documents, whether for the purchase order amount or Contractor’s handling, labor, installation, or overhead and profit. Submit claims in accordance with General Conditions – Changes in Work within twenty-one (21) days of receipt of Field Change Authorization authorizing work to proceed. The Owner will reject claims submitted later than twenty-one (21) days after such authorization. 1. Do not include Contractor’s or subcontractor’s indirect expenses in the Change Order cost amount unless it is clearly shown that the nature or extent of work has changed from what could have been foreseen from information in the Contract Documents. 2. No change to Contractor’s indirect expenses is permitted for selection of higher or lower priced materials or systems of the same scope and nature as originally indicated. 2.0 PRODUCTS – NOT USED 3.0 EXECUTION 3.1 EXAMINATION A. Examine products covered by an allowance promptly on delivery for damage or defects. Return damaged or defective products to manufacturer for replacement. CORNELL UNIVERSITY SECTION 01 21 00 Ithaca, New York ALLOWANCES ADDENDUM NO. 1 ALLOWANCES 01 21 00-4 October 6, 2020 3.2 PREPARATION A. Coordinate materials and their installation for each allowance with related materials and installations to ensure that each allowance item is completely integrated and interfaced with related work. 3.3 SCHEDULE OF ALLOWANCES A. Allowance No. 1: Lump Sum Allowance: Include the sum of $3,000.00 to cover the work identified in keyed renovation note 20 on drawing A-101. ***END OF SECTION 01 21 00** CORNELL UNIVERSITY SECTION 01 23 00 Ithaca, New York ALTERNATES ADDENDUM NO. 1 ALTERNATES 01 23 00-1 October 6, 2020 SECTION 01 23 00 ALTERNATES 1.0 GENERAL 1.1 RELATED DOCUMENTS A. This Section describes the changes to be made under each Alternative. B. The Specification Section containing the pertinent requirements of materials and methods to achieve the Work described herein. 1.2 DESCRIPTION OF REQUIREMENTS A. Definition: An alternate is an amount proposed by Bidders and stated on the Bid Proposal Submission Form and in the eBuilder Bid Module for certain items that may be added to or deducted from the Base Bid amount if the Owner decides to accept a corresponding change in either the amount of construction to be completed, or in the product, materials, equipment, systems or installation methods described in the Contract Documents. Alternates shall include all overhead, profit and other expenses, including bond costs, in connection therewith. B. Coordination: Coordinate related Work and modify or adjust adjacent Work as necessary to ensure that Work affected by each accepted alternate is complete and fully integrated into the Project. C. Notification: Immediately following Contract award, prepare and distribute to each party involved, notification of the status of each alternate. Indicate whether alternates have been accepted, rejected or deferred for consideration at a later date. Include a complete description of negotiated modifications to alternates. D. Schedule: A "Schedule of Alternates" is included at the end of this Section. Include as part of each alternate, miscellaneous devices, accessory objects or similar items incidental to or required for a complete installation whether or not mentioned as part of the alternate. 2.0 PRODUCTS – NOT USED 3.0 EXECUTION 3.1 SCHEDULE OF ALTERNATES A. ALTERNATE NO. 1 Deduct Alternate: Remove the scope associated with the door and frame replacement of Door 330-1 and leave the associated existing conditions as they currently are. ***END OF SECTION 01 23 00*** 1 1 1 2 2 2 2 2 24x8 EA 48x18 EA42x1812x12 SA DUCT MAIN ABOVE CORRIDOR CEILING (E) EA DUCT MAIN IN UTILITY CORRIDOR (E) EG-330 (E) SD1-330 (E) SD2-330 (E) SD3-330 (E) SD4-330 (E)3 VAV-53 (D) VAV-54 (D) ROOM TS (E) 2 1" HWS 1" HWR 330 4 4 4 4 5 5 EAV (E) 4 6 6 4 EAV-330-1 4' ADA FUME HOOD EAV-330-2 24x8 EA(E)48x18 EA(E)1344 CFM 1130 CFM 1 130 CFM 2 4 150 CFM 6ø EA 6ø EA8ø EA 12ø EA6495 CFM 16x12 EA EAV-330-3 742x18SAV-330-1 RHC-330 8 9 14 9 E8 LASER CUTTER E4 VACUUM PUMP 2 E3 VACUUM PUMP 1 E11 ELECTROSPINNING STATION E12 3D PRINTER E9 MILL 350 CFM 8ø 10x68ø 8ø10 11 EAV-330-4 9 VD VD 12 13 328 CFM 13 328 CFM 13 328 CFM 5 136 CFM SD5-330 SD1-330 (E) SD2-330 (E) SD3-330 (E) SD4-330 (E) 15 329 CFM 16 10ø8øVD VD VD 18x14 10 12 3 M-101R1 6ø EA VD 10ø 6ø 26 ROOM TS (E) 3 1" HWS 1" HWR 2 M-501R1 MANUAL VENTILATION SHUTOFF SWITCH 27 16ø 8ø 28 200 CFM VD VD 24x8 29 30100 CFM 10ø 6ø 6øVD 37 34 20x16 EA 35 24X16 SA (E) 32 10 35 35 FUME HOOD (E) 12ø EA 31 32 12ø EA(E) 31 6" VAC EXHAUST (E) 6" VAC EXHAUST (E) 33 18x14 36 35 EAV (E) 8ø 36 35 FD-1 FD-2 FD-3 FD-4 FSD-1 FSD-2 2" VAC 2" VAC10ø 2 38 38 38 4 6 M-501R1 4 VD 10ø EA3RD FLOOR 34' -0" PENTHOUSE LEVEL 50' -0" 3RD FLOOR 34' -0" VAC N2 CA 17 ADA FUME HOOD 18 19 20 21 22 23 25 241 1/2" LV1/2" DCW1 1/4" RODI1 1/4" RODI1/2" CA1/2" N23/4" VAC10ø8ø 1-1/2" LW4" LW (E) DCW RODI COORDINATION NOTE: HOOD (PROVIDED BY OTHERS) TO BE PROVIDED WITH INTERNAL PLUMBING, VALVES, AND FIXTURES FROM THE FACTORY MEETING SPECIFICATIONS AS OUTLINED ON THE PLUMBING PLANS. INTERNAL PLUMBING TO INCLUDE THE FOLLOWING: -VAC -N2 WITH HOOD MOUNTED REGULATOR ASSEMBLY -CA WITH HOOD MOUNTED REGULATOR ASSEMBLY -DCW WITH VACUUM BREAKER AND GOOSENECK TO CUPSINK -RODI WITH VACUUM BREAKER AND GOOSENECK TO CUPSINK 28 37 10ø EA90x48 EAEX-5 EX-6 EXHAUST DISCHARGE STACK (E) EXHAUST PLENUM (E) MECHANICAL ROOM 40060 CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 343 CAMPUS ROAD ITHACA, NEW YORK 14850 DUFFIELD HALL 330 LAB RENOVATIONS M-101R1 12672500 PARTIAL THIRD AND FOURTH FLOOR MECHANICAL PLANS E. LEPORE TRF 2000 SEPTEMBER 4, 2020 # 0' 2' 4' 8' SCALE: 1/4"=1'-0" M-101R1 KEYED DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING GENERAL EXHAUST AIR VALVE AND ASSOCIATED ACCESSORIES. REMOVE PORTION OF EXHAUST DUCTWORK TO PREPARE FOR RECONNECTION. 2 REMOVE EXISTING SUPPLY AIR VALVE, REHEAT COIL PIPING, REHEAT COIL CONTROL VALVE, ASSOCIATED ACCESSORIES, AND PORTION OF SUPPLY AIR DUCTWORK AS REQUIRED FOR THE RENOVATIONS. 3 DISCONNECT AND RETAIN EXISTING SUPPLY AIR DIFFUSER. HOLD ON SITE FOR REINSTALLATION. 4 DISCONNECT AND REMOVE PORTION OF EXISTING SUPPLY AIR DUCT SERVING UTILITY CORRIDOR AS REQUIRED TO PREP FOR FIRE DAMPER INSTALLATION. RETAIN EXISTING SUPPLY AIR GRILLE FOR REINSTALLATION. 5 DISCONNECT AND REMOVE EXISTING EXHAUST AIR DUCT ATTENUATOR 6 DISCONNECT AND REMOVE PORTION OF EXISTING EXHAUST AIR DUCT AS REQUIRED TO INSTALL FIRE DAMPER IN WALL. #M-101R1 KEYED RENOVATION NOTES 1 PROCESS EXHAUST DROP DOWN TO EXHAUST ENCLOSURE. PROVIDE BLAST GATE DAMPER AND BALANCE TO AIRFLOW SPECIFIED. ENCLOSURE PROVIDED BY OTHERS. 2 DROP 2" 304 STAINLESS STEEL VACUUM PUMP EXHAUST PIPE DOWN TO VACUUM PUMP. REFER TO DETAIL 6/M-501R1. 3 CONNECT TO EXISTING REHEAT HOT WATER PIPING AND EXTEND 3/4" HOT WATER SUPPLY AND HOT WATER RETURN TO REHEAT COIL. PROVIDE PIPING PER DETAIL AND BALANCE FLOW PER SCHEDULE. 4 6" EXHAUST DUCT DROP TO SNORKEL ARM WITH 14" SNORKEL HOOD. BASIS OF DESIGN - MONOXIVENT MODEL MNX-CDH-100. SERVES 3D PRINTER AND FINISHING STATION. PROVIDE WITH BLAST GATE DAMPER. REFER TO DETAIL 2/M-501. 5 SOLDERING IRON. LOCATION SHOWN FOR TEMPORARY STORAGE. WHEN IN USE, SOLDERING PROCESS TO BE PERFORMED INSIDE ONE OF THE EXHAUSTED ENCLOSURES OR THE FUME HOOD. 6 10" DIA EXHAUST DROP DOWN TO ADA FUME HOOD. PROVIDE BLAST GATE DAMPER. CONNECT TO HOOD WITH FLEXIBLE METAL DUCT. REFER TO DETAIL 3/M-101. FUME HOOD PROVIDED BY OTHERS 7 PROVIDE 8"DIA RIGID METAL DUCT ALONG WALL DOWN TO LASER. PROVIDE FLEX DUCT CONNECTION AT LASER. 3 FOOT MAX LENGTH OF FLEX. 8 PROVIDE SUPPLY AIR VALVE AND REHEAT COIL. CONNECT DIGITAL CONTROL TO BMS. 9 PROVIDE EXHAUST AIR VALVE. CONNECT DIGITAL CONTROL TO BMS. 10 PROVIDE 1-1/2 HR STATIC RATED FIRE DAMPER, TYPE B, AT RATED WALL PENETRATION. PROVIDE RETAINING ANGLE AND INSTALL PER UL LISTED INSTALLATION INSTRUCTIONS. 11 FUME FILTER/FAN COMBINATION - FUMEX MODEL FA5. FUME FILTER/FAN BY OTHERS. MECHANICAL CONTRACTOR TO PROVIDE DUCT AND CONTROL CONNECTIONS. PROVIDE FLEX DUCT CONNECTIONS AT THE FUME FILTER/FAN 3' MAX LENGTH FLEX ON INLET AND OUTLET. POWER BY ELECTRICAL CONTRACTOR. 12 EXHAUSTED ENCLOSURE PROVIDED BY OWNER. PROVIDE GLYCOL SMOKE TEST. AFTER APPROVED TESTING AND BALANCING OF THE PROCESS EXHAUST, CONTACT EHS, MECHANICAL ENGINEER, BALANCER AND CONTROLS CONTRACTOR WITH TWO WEEKS NOTICE TO SCHEDULE A GLYCOL SMOKE TEST OF THE EXHAUSTED ENCLOSURE TO VERIFY THE CAPTURE VELOCITY. PROVIDE VIDEO DOCUMENTING OF GLYCOL SMOKE TEST. UNSATISFACTORY TESTING WILL REQUIRE REBALANCING OF THE ENCLOSURE AT THE TIME OF TESTING. INCREASE EXHAUST AIRFLOW AND CAPTURE VELOCITY AS NECESSAR FOR A SATISFACTORY TEST. SIGN-OFF BY EHS AND ENGINEER IS REQUIRED AT THE CONCLUSION OF THIS TEST. 13 REBALANCE EXISTING CEILING SUPPLY DIFFUSER TO 328 CFM. 14 PROVIDE NEW FUME HOOD EXHAUST AIR VALVE AND CONNECT TO EXISTING BUILDING AUTOMATION AND CONTROL SYSTEM. PROVIDE FUME HOOD CONTROLLER AND SASH POSITION SENSORS. 15 REINSTALL EXISTING CEILING SUPPLY DIFFUSER. PROVIDE WITH MANUAL BALANCING DAMPER AND BALANCE TO AIRFLOW SHOWN. 16 TRANSITION TO RECTANGULAR NECK DIFFUSER. MODULAR CORE, 2-WAY DIFFUSER. ADJUST CORE FOR AIR PATTERN SHOWN. 17 REFER TO ARCHITECTURAL DRAWINGS FOR ADA ACCESSIBLE FUME HOOD AND ADJUSTABLE BASE. 18 FUME HOOD WORK SURFACE SHALL BE 36-INCHES ABOVE FINISH FLOOR FOR NON-ADA HEIGHT AND 30-INCHES ABOVE FINISH FLOOR FOR ADA HEIGHT. 19 PROVIDE 1-1/2" DRUM TRAP. PROVIDE SUFFICIENT PIPE ON INLET TO ALLOW 6" OF WORKSURFACE ADJUSMENT. 20 PROVIDE 1-1/4" DRAIN FROM CUP SINK. PROVIDE SUFFICIENT TAILPIECEON OUTLET TO ALLOW FOR 6" OF WORK SURFACE ADJUSTMENT. DRAIN IS TO BE SLEEVED WITHIN THE 1-1/2" INLET PIPE PROVIDED ON THE DRUM TRAP. 21 CONNECT 1-1/2" DRAIN TO LAB WASTE PIPING ABOVE SECOND FLOOR CEILING. CORE DRILL OPENING THROUGH THIRD FLOOR SLAB AS REQUIRED TO ROUTE PIPING TO SECOND FLOOR. PROVIDE 2-HR RATED PENETRATION SYSTEM. FIELD VERIFY PENETRATION LOCATION AND COORDINATE WITH EXISTING STRUCTURE/UTILITES. CUP SINK AND HOOD BY OTHERS. 22 PROVIDE 1-1/4" VENT SERVING CUP SINK DRAIN. ROUTE PIPING ALONG WALL ADJACENT TO FUME HOOD AND CONNECT TO EXISTING 2" LAB VENT PIPING ABOVE CEILING. 23 COORDINATE INSTALLATION OF DUCT WITH SUSPENDED LAY-IN ACOUSTICAL CEILING SYSTEM. PROVIDE OPENING THROUGH TILE/GRID SUFFICIENT FOR THE ROUNE ROUND DUCTWORK PENETRATION. 24 FLEXIBLE EXHAUST DUCT SHALL BE FLEXHAUST BENDWAY-PLUS OR EQUAL, 316Ti STAINLESS STEEL, 10-INCH ROUND NOMINAL DIMENSION. 25 FUME HOOD LAB SERVICES CONNECTIONS. PROVIDE STAINLESS STEEL FLEXIBLE CONNECTIONS TP PRE-PIPED 26 PROVIDE DUCT ACCESS DOOR AT REHEAT COIL FOR INSPECTION AND MAINTENANCE. 27 PROVIDE MANUAL VENTILATION SHUTOFF SWITCH, BASIS OF DESIGN PILLA ELECTRICAL ST120. SWITCH SHALL BE LABELED "VENTILATION SYSTEM EMERGENCY SHUTOFF". CONNECT TO CONTROLS OF ALL SUPPLY AND EXHAUST AIR VALVES SERVING 330. CONTROL CONTRACTOR TO PROVIDE LOW VOLTAGE CONTROL WIRE ALONG WALL SURFACE INSIDE ROOM 330. SURFACE RACEWAY SHALL BE WIREMOLD 700. FIRESTOP CONDUIT PENETRATION IN WALL AND MAINTAIN WALL RATING. 28 DROP 8" DIA EXHAUST AIR DUCT DOWN TO FLOOR. TERMINATE 12" AFF WITH 1/2" ALUMINUM MESH. BALANCE TO 200 CFM WITH GENERAL EXHAUST VALVE IS SET TO MAX FLOW PER AIRFLOW SCHEDULE. 29 CONTROL CONTRACTOR TO PROVIDE THE LASER POWER RELAY CAT. NO. RIBU1C AT LOCATION SHOWN. COORDINATE WITH THE ELECTRICAL CONTRACTOR TO RUN NEAREST 120V POWER TO THE DEVICE. LOW VOLTAGE WIRING BY THE CONTROL CONTRACTOR. SURFACE REACEWAY FOR THE 120V POWER SHALL BE A WIREMOLD 700. 30 DROP 6" DIA SUPPLY AIR DUCT DOWN TO FLOOR. TERMINATE 12" AFF WITH 1/2" ALUMINUM MESH. BALANCE TO 100 CFM WHEN SUPPLY VALVE IS SET TO MAX FLOW PER AIRFLOW SCHEDULE. 31 PROVIDE RATED DUCT WRAP SYSTEM ON 12" EXHAUST DUCT, FIREMASTER FASTWRAP OR EQUAL. INSTALL ONE LAYER PER MANUFACTURER'S UL LISTED INSTALLATION INSTRUCTIONS. 32 INSTALL FIRE RATED THROUGH PENETRATION SYSTEM PER DETAIL 3/M-501R1 33 PROVIDE HOUSING AND FIRE WRAP EXISTING EXHAUST VALVE. PROVIDE ACCESS TO ACTUATOR AND CONTROLS. REFER TO DETAIL 5/M-501R1. 34 PROVIDE 24x16, 1-1/2 HR STATIC RATED FIRE DAMPER, TYPE A. INSTALL WITH RETAINING ANGLE AND PER UL LISTED INSTRUCTIONS. REINSTALL SUPPLY GRILLE. 35 PROVIDE DUCT ACCESS TO FIRE DAMPER. 36 PROVIDE 1-1/2 HR COMBINATION FIRE SMOKE DAMPER, CLASS I LEAKAGE. PROVIDE WITH RETAINING ANGLE AND 120V ACTUATOR. CIRCUIT TO NEAREST 120V POWER. WIRE TO EXISTING AREA SMOKE DETECTION SYSTEM AND FIRE ALARM CONTROL PANEL. REFER TO ELECTRICAL DRAWINGS FOR CONNECTIONS TO FIRE ALARM SYSTEM. 37 PROVIDE OPENING IN EXISTING CONCRETE DECK AS REQUIRED TO EXTEND STAINLESS STEEL EXHAUST DUCT UP TO PENTHOUSE. INSTALL FIRE RATED THROUGH PENETRATION SYSTEM PER DETAIL 4/M-501. 38 2" 304 STAINLESS STEEL EXHAUST PIPE AND FITTINGS, BUTT WELD ENDS, SERIES 23, 0.065" WALL THICKNESS, MKS MODEL 100314306 OR EQUAL. SCALE:1/4" = 1'-0"1 PARTIAL THIRD FLOOR HVAC DEMOLITION PLAN SCALE:1/4" = 1'-0"2 PARTIAL THIRD FLOOR HVAC CONSTRUCTION PLAN SCALE:1/2" = 1'-0"3 ADA FUME HOOD ELEVATION 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% CD REVIEW 3 09/4/2020 ISSUE FOR CONSTRUCTION 4 10/06/20 ISSUE FOR ADDENDUM NO. 1 0' 1' 2' 4' SCALE: 1/2"=1'-0" 4 SCALE:1/8" = 1'-0"4 PARTIAL FOURTH FLOOR HVAC CONSTRUCTION PLAN 4 GENERAL NOTE: ALL PIPE AND DUCT WALL PENETRATIONS ARE TO BE FIRE STOPPED OR PROTECTED BY THE APPROPIRATE LIFE-SAFETY DAMPERS AS INDICATED. 4 4 4 4 SUPPLY RETURN ISOLATION VALVE (TYP. OF 2) BALANCING VALVE PRESSURE/TEMPERATURE TEST PORT (TYP. OF 2) MANUAL AIR VENT COIL CV-330-RH 3RD FLOOR 34' -0" 3RD FLOOR 34' -0" 6" EA ON WALL 4" CONNECTION WALL MOUNTING BRACKET 4" LOCAL EXHAUST EXTRACTION ARM. BASIS OF DESIGN - MONOXIVENT MODEL MHX-CDH-100 WALL (E) LAB BENCH (E) CEILING (E) 14" DOME HOOD EXTRACTION ARM COORDINATION: OFFSET LOCATION OF WALL BRACKET AND EXTRACTION ARM MOUNTING AS RECOMMENDED BY THE MANUFACTURER AND AS NECESSARY FOR PROPER REACH OF THE HOOD TO THE 3D PRINTER AND FINISHING STATION. FIELD/SHOP FABRICATED ENCLOSURE. SHEET STEEL MIN 24 GA. ONE LAYER OF FIRE RATED DUCT ENCLOSURE WRAP. FIREMASTER FASTWRAP OR EQUAL. 12ø EA 12" DIA FUME HOOD EA (E) EXHAUST AIR VALVE SERVING 328 (E) CONTROL PANEL (E) RATED ACCESS DOOR TO CONTROL PANEL AND ACTUATOR. FACTORY PROVIDED, UL LISTED OR FIELD FABRICATED ACCORDING TO DUCT WRAP MANUFACTURER'S UL LISTED INSTRUCTIONS. 2" 304 SS BLAST GATE VACUUM PUMP (BY OTHERS) FLEX TUBING, PITCH DOWN (BY OTHERS) WORK SURFACE 3/4" THREADED SIGHT GLASS. JOHN C. ERNST MODEL 120 OR EQUAL 3/4" THREADED BALL VALVE. MILWAUKEE MODEL 20SS OR EQUAL 2" WELDED 304 SS VAC PUMP EXHAUST PIPE 2" FLANGED OUTLET CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 343 CAMPUS ROAD ITHACA, NEW YORK 14850 DUFFIELD HALL 330 LAB RENOVATIONS M-501R1 12672500 SCHEDULES AND DETAILS E. LEPORE TRF 2000 SEPTEMBER 4, 2020 DUCT SCHEDULE AND SPECIFICATIONS SERVICE PRESSURE CLASS SEAL CLASS LEAKAGE CLASS DUCT MATERIAL LINING DUCT INSULATION SUPPLY, RECTANGULAR, EXPOSED, AHU - VAV (EXPOSED IN UTILITY CORRIDOR) 4" POS A 6 G90 GALVANIZED NONE MIN R-6, TYPE B, WITH VAPOR RETARDER, PAINT SUPPLY, RECTANGULAR, CONCEALED (ABOVE DROP CEILING)4" POS A 6 G90 GALVANIZED NONE MIN R-6, TYPE A WITH VAPOR RETARDER SUPPLY, RECTANGULAR, CONCEALED, TERMINAL UNIT - OUTLET 2" POS A 6 G90 GALVANIZED NONE MIN R-6, TYPE A WITH VAPOR RETARDER SUPPLY, ROUND, CONCEALED, TERMINAL UNIT - OUTLET 2" POS A 3 G90 GALVANIZED NONE MIN R-6, TYPE A WITH VAPOR RETARDER EXHAUST: LABORATORY - ACCESSIBLE LOCATIONS AND RISERS 4" NEG A RECT 6/ROUND 3 316 STAINLESS STEEL, WELDED NONE N/A EXHAUST: FUME HOOD - CONNECTION OF DUCT TO MAIN 4" NEG A RECT 6/ROUND 3 316 STAINLESS STEEL, WELDED NONE N/A AIRFLOW SCHEDULE LAB ROOM DIMENSIONS EXHAUST AIR SUPPLY POINT OCC SASH OPEN (100 FPM) OCC SASH OPEN (80 FPM) OCC SASH CLOSED UNOCC SASH FULL UNOCC SASH OPEN UNOCC SASH CLOSED ALL MODESAREA (SF) HEIGHT (FT) EXHAUST POINT VALVE OCC SASH OPEN (100 FPM) OCC SASH OPEN (80 FPM) OCC SASH CLOSED OCC LASER OFF UNOCC SASH FULL UNOCC SASH OPEN UNOCC SASH CLOSED 330 536 10 4' ADA FUME HOOD EAV-330-1 495 CFM 395 CFM 140 CFM 190 CFM 495 CFM 322 CFM 140 CFM SAV-330 1549 CFM 1549 CFM 1549 CFM 747 CFM 574 CFM 574 CFM -200 CFM GENERAL EXHAUST EAV-330-2 150 CFM 250 CFM 505 CFM 805 CFM 50 CFM 50 CFM 50 CFM PROCESS EXHAUST EAV-330-3 754 CFM 754 CFM 754 CFM 754 CFM 402 CFM 402 CFM 402 CFM LASER EXHAUST EAV-330-4 350 CFM 350 CFM 350 CFM 0 CFM 0 CFM 0 CFM 0 CFM TOTAL LAB 1749 CFM 1749 CFM 1749 CFM 1749 CFM 947 CFM 774 CFM 774 CFM CONTROL VALVE SCHEDULE & SPEC TAG BOD MANF BOD VALVE MODEL SERVICE VALVE TYPE VALVE SIZE (IN)CV ACTUATOR MODEL CONTROL CAPACITY (GPM)PD (PSIG) FAIL POS CV-330-RH1 BELIMO CCV - B213 RHC-330-1 2-WAY 1/2 1.9 TR24-SR-T US MOD 2.2 1.3 F.L. 1. ACCEPTABLE MANUFACTURERS: BELIMO, VSI 2. ELECTRIC INPUT: 4-20mA OR 0-10VDC 3. 2-WAY VALVES: EQUAL PERCENTAGE FLOW CHARACTERISTIC 4. CONSTRUCTION: CHARACTERIZING DISK, FORGED BRASS, NICKEL PLATED BODY, STAINLESS STEEL BALL AND STEM, FIBERGLASS REINFORCED PTFE SEAT 5. RATINGS: 400 PSI PRESSURE, 0-212 F MEDIA TEMPERATURE RANGE 6. ALL CONTROL WIRING SHALL BE INSTALLED IN CONDUIT. 7. CONTROL WIRING SHALL BE UNSPLICED FROM THE CONTROLLER TO THE SENSOR OR DEVICE. 8. CONTROL WIRING SHALL NOT BE ROUTED IN THE SAME RACEWAY AS POWER WIRING. 9. CONTROL WIRING SHALL BE COLOR CODED AND LABELED AT ALL POINTS OF TERMINATION. 10. TEST EACH POINT THROUGH IT FULL OPERATING RANGE TO VERIFY THAT SAFETY AND OPERATING CONTROL SET POINTS ARE AS REQUIRED. 11. TEST EACH CONTROL LOOP TO VERIFY STABLE MODE OF OPERATION AND COMPLIANCE WITH SEQUENCE OF OPERATION. ADJUST PID ACTIONS AS REQUIRED. 12. THE BACS CONTRACTOR SHALL ISSUE A REPORT UPON PROJECT COMPLETION STATING THAT THE SYSTEM IS COMPLETE, HAS BEEN ADJUSTED, AND HAS HAD ALL HARDWARE AND SOFTWARE FUNCTIONS VERIFIED, THAT ALL ANALOG CONTROL LOOPS ARE TUNED, AND IS OPERATING IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. ANY DEVIATIONS FROM SPECIFIED SETTINGS OR OPERATIONS NECESSITATED DURING SYSTEM ADJUSTMENT SHALL BE SPECIFICALLY NOTED. AIR VALVE SCHEDULE & SPECS TAG # SERVES SUP EXH BASIS OF DESIGN SIZE DESIGN CFM ΔPT @ MAX DESIGN CFM REHEAT COIL TAG DAMPER POSITIONMANF MODEL MAX MIN EAV-330-1 330 LAB - FUME HOOD X ACCUVALVE AVC6308-05-WS 8" 495 140 0.6 N.O. EAV-330-2 330 LAB - GENERAL EXH X ACCUVALVE AVC6310-05-WS 10" 805 50 0.6 N.O. EAV-330-3 330 LAB - PROCESS X ACCUVALVE AVC6310-05-WS 10" 804 402 0.6 N.O. SAV-330-1 330 LAB - SUPPLY AIR X ACCUVALVE AVC6414-05-IWS 14" 1549 574 0.6 RHC-330 N.C. EAV-330-4 330 LAB - LASER X ACCUVALVE AVC6408-05-WS 8" 350 80 0.6 N.O. 1. THE AIRFLOW DEVICES SHALL BE CALIBRATED AT THE FACTORY TO THE FULL RANGE OF RECOMMENDED AIRFLOWS. ACTUAL AIRFLOWS WILL BE SET IN SOFTWARE. 2. SETPOINTS REPRESENT FUME HOOD FACE VELOCITY AT 100 FPM. FINAL SETPOINTS WILL BE ADJUSTED IF FACE VELOCITIES ARE REDUCED TO 80 FPM AS A RESULT OF FUME HOOD TESTING AND CERTIFICATION. 3. ACCEPTABLE MANUFACTURERS: ACCUTROL 4. CONFIGURATION: PRESSURE INDEPENDENT. 5. SUPPLY VALVE BODY: 16GA ALUMINUM, INSULATED. 6. HOOD EXHAUST VALVE BODY: 20 GA 316 STAINLESS STEEL. 7. INSTALLATION: LEVEL AND PLUMB, PER NFPA 90A, SMACNA DUCT CONSTRUCTION STANDARDS, AND MANUFACTURERS RECOMMENCED INSTRUCTIONS. 8. PROVIDE ALL VALVES WITH TIGHT SHUT-OFF OPTION. 1. ALL DUCTWORK AND ACCESSORIES SHALL BE FABRICATED AND INSTALLED IN COMPLIANCE WITH THE LATEST ISSUE OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE. 2. CONSTRUCT TEES, BENDS, AND ELBOWS WITH RADIUS OF NOT LESS THAN 1.0 TIMES THE WIDTH OF DUCT ON CENTER LINES. 3. WHERE RECTANGULAR ELBOWS ARE USED, PROVIDE AIR FOIL TYPE TURNING VANES 4. INCREASE DUCT SIZES GRADUALLY, AND IN COMPLIANCE WITH FIGURE 4-7 OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE. 5. BRANCH CONNECTIONS SHALL BE MADE WITH A 45 DEGREE ENTRY. STRAIGHT TEES ARE NOT ACCEPTABLE. 6. SEALANTS AND GASKETS: SURFACE BURNING CHARACTERISTICS SHALL BE A MAXIMUM FLAME-SPREAD INDEX OF 25, AND MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED TO UL 723. 7. ALL MANUAL BALANCING DAMPERS SHALL BE PROVIDED WITH LOCKING HAND QUADRANT. 8. ACCESS DOORS SHALL MATCH DUCT MATERIAL WITH INSULATION FILL AND THICKNESS AS INDICATED FOR DUCT PRESSURE CLASS. 9. ACCESS DOORS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: BOTH SIDES OF DUCT COILS IN ORDER TO RESET OR REINSTALL FUSIBLE LINKS, AND AS INDICATED. 10. INSTALL VOLUME DAMPERS AT POINTS ON SUPPLY AND EXHAUST SYSTEMS WHERE BRANCHES EXTEND FROM LARGER DUCTS. 11. PAINT ALL DUCTWORK EXPOSED TO VIEW IN OCCUPIED AREAS TO MATCH SURROUNDING FINISH. 12. REMOVE SURFACE CONTAMINANTS AND DEPOSITS FROM DUCTWORK AND EQUIPMENT PRIOR TO TESTING AND BALANCING. 13. LEAK TESTING OF DUCTWORK SHALL BE IN ACCORDANCE WITH SMACNA'S HVAC AIR DUCT LEAKAGE TEST MANUAL. 14. ALL DUCTS DESIGNED TO OPERATE AT STATIC PRESSURES IN EXCESS OF 3-INCHES WG (POS OR NEG) SHALL BE TESTED. TEST SHALL BE WITNESSED BY A DESIGNATED CORNELL REPRESENTATIVE AND THE PROJECT ENGINEER OF RECORD. 25% OF DUCTS DESIGNED TO OPERATE AT STATIC PRESSURES 3-INCHES AND BELOW SHALL BE TESTED. ACCEPTANCE CRITERIA: INTERIOR SUPPLY, RETURN AND GENERAL EXHAUST: 5% SYSTEM LEAKAGE TESTED AT 1.25 TIMES THE EXPECTED OPERATING STATIC PRESSURE. ACCEPTANCE CRITERIA: INTERIOR LABORATORY EXHAUST SYSTEMS: 2% SYSTEM LEAKAGE TESTED AT 1.25 TIMES THE EXPECTED OPERATING STATIC PRESSURE. AN AIR DUCT LEAKAGE TEST SUMMARY SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO FINAL PROJECT ACCEPTANCE. 15. ALL INSULATION AND ADHESIVE SHALL HAVE A MAXIMUM FLAME-SPREAD INDEX OF 25 AND A MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84. 16. INSULATION TYPE A: MINERAL FIBERGLASS BLANKET, ASTM C553 TYPE I, ASTM C1136 TYPE I FACTORY APPLIED FSK JACKET, K-VALUE BETWEEN 0.22 -0.29 BTU-IN/HR-FT²-˚F @ 75 ˚F, 0.75 PCF 1. COORDINATE WITH CORNELL EH&S DURING FUME HOOD TESTING AND CERTIFICATION. REDUCTION IN THE FUME HOOD FACE VELOCITY TO 80 FPM MAY BE POSSIBLE. HVAC PIPE AND FITTING SCHEDULE AND SPECIFICATIONS PIPE SERVICE ABBREVIATION PIPE SIZE MATERIAL FITTINGS JOINT INSULATION HEATING HOT WATER HWS&R 1-1/2" & BELOW ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER 1", TYPE A WITH VAPOR RETARDER GRILLE SCHEDULE MARK SERVES MANUFACTURER (BOD) MODEL (BOD) TYPE AIRFLOW DUCT SIZE SPECIFICATIONS SD4-330 (E) LAB 330 EXISTING EXISTING EXISTING 329 CFM 10ø EXISTING SD5-330 LAB 330 KRUEGER SERIES 51240 MODULAR CORE 136 CFM 6ø 24"X24" PANEL SIZE, 8"X8" NECK, ALUMINUM WITH WHITE FINISH 1. ACCEPTABLE MANUFACTURERS: ANEMOSTAT, CARNES, KRUEGER, PRICE, TITUS. REHEAT COIL SCHEDULE TAG COIL SIZE WxH (IN)ROWS TOTAL CAPACITY (BTUH) AIR SIDE WATER SIDE FLOW RATE (CFM) ENT AIR TEMP (˚F) LVG AIR TEMP (˚F) AIR PRESSURE DROP (IN WC) FOW RATE (GPM) ENT WATER TEMP (˚F) LVG WATER TEMP(˚F) WATER PRESSURE DROP (FT WC) RHC-330 24x12 2 33,458 1549 55 75 0.55 2.2 130 100 3.0 1. ACCEPTABLE MANUFACTURERS: GREENHECK, ANEMOSTAT, KRUEGER, NAILOR, TITUS, TRANE, PRICE TO COORDINATE WITH AIR TERMINAL BOX. 2. RATINGS: ARI 410, INDUSTRY STANDARD FOR FORCED CIRCULATION AIR COOLING AND AIR HEATING COILS 3. 1/2-IN COPPER TUBING WITH MECHANICALLY BONDED ALUMINUM FINS. 4. SUPPLY PIPING TO COIL TO BE PIPED WITH SHUT OFF VALVE, STRAINER, CONTROL VALVE AND UNION. 5. RETURN PIPING TO COIL TO BE PIPED WITH SHUT-OFF VALVE, BALANCING VALVE, AND UNION. 6. COIL SHALL BE PIPED IN COUNTERFLOW ARRANGEMENT. 7. PIPING SHALL BE ARRANGED TO ALLOW SERVICE AND MAINTENANCE. NOT TO SCALE1REHEAT COIL PIPING DETAIL 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% CD REVIEW 3 09/4/2020 ISSUE FOR CONSTRUCTION 4 10/06/20 ISSUE FOR ADDENDUM NO. 1 SCALE:1/2" = 1'-0"2 EXTRACTION ARM DETAIL FIRE AND SMOKE DAMPER SCHEDULE TAG LOCATION MANF BOD MODEL BOD TYPE SIZE WxH (IN) TEMP RATING (DEG F) FIRE RATING SMOKE RATING NOTESHOURS UL HOURS UL FD-1 LAB 330 GREENHECK FD-150 STATIC, TYPE A 24x16 165 1-1/2 1-1/2 N/A N/A GALVANIZED, FUSIBLE LINK, VERTICAL MOUNTING FD-2 LAB 330 GREENHECK SSFD-150X16 STATIC, TYPE B 20x16 165 1-1/2 1-1/2 N/A N/A 304 STAINLESS STEEL, FUSIBLE LINK, VERTICAL MOUNTING FD-3 LAB 330 GREENHECK SSFD-150X16 STATIC, TYPE B 12X12 165 1-1/2 1-1/2 N/A N/A 304 STAINLESS STEEL, FUSIBLE LINK, VERTICAL MOUNTING FD-4 LAB 330 GREENHECK SSFD-150X16 STATIC, TYPE CR 8 165 1-1/2 1-1/2 N/A N/A 304 STAINLESS STEEL, FUSIBLE LINK, VERTICAL MOUNTING FSD-1 LAB 330 GREENHECK FSD-311 COMBINATION FIRE SMOKE 18x14 165 1-1/2 1-1/2 1-1/2 1-1/2 GALVANIZED STEEL, ACTUATED, VERTICAL MOUNTING FSD-2 LAB 330 GREENHECK FSD-311 COMBINATION FIRE SMOKE 8 165 1-1/2 1-1/2 1-1/2 1-1/2 GALVANIZED STEEL, ACTUATED, VERTICAL MOUNTING 1. ACCEPTABLE MANUFACTURERS: GREENHECK, NAILOR, RUSKIN 2. RATINGS: UL 555 3. FRAME: 20 GAUGE STEEL CHANNEL, WITH MITERED AND INTERLOCKING CORNERS 4. MOUNTING SLEEVE: FACTORY FURNISHED, MINIMUM 20 GAUGE. 5. BLADES: 24 GAUGE THICKNESS. 6. INSTALLATION: INSTALL FIRE DAMPERS IN ACCORDING TO UL LISTING AND MANUFACTURERS RECOMMENDED INSTRUCTIONS. 7. PROVIDE ACCESS TO FUSIBLE LINK, EITHER WITH DUCT ACCESS DOOR, OR THRU THE WALL GRILLE 4 NOT TO SCALE3RATED WALL DUCT PENETRATION DETAIL NOT TO SCALE4RATED FLOOR DUCT PENETRATION DETAIL 4 4 SCALE:1/2" = 1'-0"5 VALVE ACCESS ENCLOSURE DETAIL ENCLOSURE NOTES: FABRICATED CUSTOM ENCLOSURE TO HOUSE THE EXISTING FUME HOOD EXHAUST VALVE SERVING ROOM 328. THE PURPOSE OF THIS ENCLOSURE IS TO MAINTAIN OPERATION AND ACCESS TO THE EXHAUST VALVE SCALE:1/2" = 1'-0"6 VACUUM PUMP CONNECTION DETAIL 4 4 4 3 3 F330 2 1 OS OS S 330 4 3 8 8 330 (3) (3) (3) (3) (3) (3) (3)(3)(3) (3)(3) WIREMOLD 4000 WIREMOLD 4000 WIREMOLD 4000 EXISTING PHONE JACK EXISTING PANEL LPP-312, 208Y/120V EXISTING PENDANT POWER & DATA RACEWAY 1 2 5 6 GFCI GFCI GFCI GFCI 7 9 COMBINATION FIRE SMOKE DAMPER 9 COMBINATION FIRE SMOKE DAMPER 4 4 NOTE: IN ADDITION TO THE REMOTE TEST STATION AND STATUS ANNUNCIATION FOR THE SMOKE DETECTOR, A REMOTE TEST STATION AND STATUS ANNUNCIATION SHOULD BE PROVIDED FOR THE DAMPER AS WELL.CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 343 CAMPUS ROAD ITHACA, NEW YORK 14850 DUFFIELD HALL 330 LAB RENOVATIONS E-101R1 12672500 POWER, DATA, LIGHTING, AND FIRE ALARM PARTIAL THIRD FLOOR PLAN H. TRAN JD 2000 SEPTEMBER 4, 2020 # 0' 2' 4' 8' SCALE: 1/4"=1'-0" E-101 KEYED DEMOLITION NOTES 1 REMOVE LUMINAIRE AS INDICATED AND RETURN LUMINAIRE TO THE OWNER. MODIFIED EXISTING LIGHTING AS REQUIRED. 2 DURING CONSTRUCTION, PROVIDE A TEMPORARY HEAT DETECTOR IN THIS ROOM. SCALE:1/4" = 1'-0"1 PARTIAL THIRD FLOOR DEMOLITION SCALE:1/4" = 1'-0"2 PARTIAL THIRD FLOOR LIGHTING AND FIRE ALARM SCALE:1/4" = 1'-0"3 PARTIAL THIRD FLOOR POWER & DATA E-101 KEYED RENOVATION NOTES 1 AT 18" AFF TO TOP OF BOX, PROVIDE A SURFACE MOUNT RECEPTACLE. CIRCUIT THE RECEPTACLE TO THE NEW FUME HOOD CIRCUITRY. SURFACE RACEWAY SHALL BE WIREMOLD 700. 2 NEW ADA FUME HOOD BY OTHERS. ELECTRICAL CONTRACTOR TO PROVIDE POWER CONNECTION. CIRCUIT TO A SPARE 20A/1P CIRCUIT BREAKER LOCATED IN EXISTING PANEL LPP-312. CONDUIT CONNECTED TO THE FUME HOOD SHALL BE FLEXIBLE CONDUIT WITH (2) 12 AWG & (1) 12 AWG GROUND. 3 PROVIDE A NEW SURFACE MOUNT LIGHT SWITCH TO CONTROL THE TWO EXISTING LUMINAIRES LOCATED IN THE NEW CURTAIN. MODIFY THE EXISTING LIGHTING CIRCUIT AS REQUIRED. CIRCUIT THE LIGHTING SWITCH TO THE EXISTING LIGHTING CIRCUITRY. SURFACE RACEWAY ON WALL SHALL BE WIREMOLD 700. 4 THE CONTRACTOR TO PURCHASE A TOTAL OF 6 DARK AMBER UV BLOCKING TUBE GUARD W/ END CAPS CAT. NO. PLAS-T8UVA FROM 1000BULBS.COM. PROVIDE THE EXISTING LAMPS WITH THE TUBE GUARDS. 5 REPLACE EXISTING RECEPTACLES WITH NEW GFCI RECEPTACLES. 6 AT 18" AFF TO TOP OF BOX PROVIDE A NEW SURFACE MOUNT RECEPTACLE. CIRCUIT THE RECEPTACLE TO A SPARE 20A/1P CIRCUIT BREAKER LOCATED IN EXISTING PANEL LPP-312. PROVIDE (2) #12 AWG AND (1) #12 AWG GROUND IN 3/4" EMT AS REQUIRED. 7 LASER SAFETY LINE VOLTAGE RELAY INSTALL BY THE CONTROL CONTRACTOR. ELECTRICAL CONTRACTOR TO PROVIDE 120V POWER CONNECTION. CIRCUIT TO NEAREST 120V RECEPTACLE CIRCUIT. RACEWAY ON WALL SHALL BE WM 700. 8 REMOVE, STORE, AND REINSTALL CEILING MOUNTED EQUIPMENT AS REQUIRED DURING CEILING REMOVAL TO ACCOMMODATE MECHANICAL WORK. 9 COMBINATION FIRE SMOKE DAMPER WITH REMOTE TEST SWITCH WITH OPEN/CLOSE INDICATOR LIGHTS BY MECHANICAL CONTRACTOR. ELECTRICAL TO PROVIDE 120V POWER CONNECTION AND FIRE ALARM CONNECTION. CIRCUIT THE ACTUATOR TO NEAREST 120V POWER CIRCUITRY. REFER TO FIRE/SMOKE DAMPER CONTROL CIRCUIT WIRING ON THIS SHEET FOR FIRE ALARM WORK REQUIREMENTS. REFER TO MECHANICAL DRAWINGS FOR FIRE SMOKE DAMPER. # 1 07/24/2020 ISSUE FOR DD REVIEW 2 08/14/2020 ISSUE FOR 90% REVIEW 3 09/04/2020 ISSUE FOR CONSTRUCTION 4 10/06/20 ISSUE FOR ADDENDUM NO. 1 SCALE:NO SCALE4FIRE/SMOKE DAMPER CONTROL CIRCUIT WIRING DIAGRAM 4 4 PROJECT: Duffield Hall 330 Lab Renovations Date: October 6, 2020 RFI Form RFI/Page/ Response Dwg./Spec./Rep.Section/Design Team Index Number Paragraph/Topic RFI Response 1 A-101 What species are the wood items (oak, maple, etc.)?See Addendum 1, Item 3. 2 P-001 Lab waste and vent piping calls for polyproplyne schedule 40 pipe with stainless steel compression fittings, is this correct?" See Addendum 1, Item 7.