Loading...
HomeMy WebLinkAbout20-NJ079_P-200 PLUMBING DETAILS-P-200WALL HUNG WATER CLOSETAMERICAN STANDARDMODEL 2257.103DUAL FLUSH,TOP SPUD FLUSH VALVESLOAN VALVE UPPERCUTMODEL WES-111ADJUSTABLE CLOSET CARRIERWATTS DRAINAGEMODEL ISCA-101-L/RFINISHED FLOOR2" VENT1" CW SUPPLYMIN. 11" CLEARMAX. 16" CLEAR4" SANITARY WASTEPLUMBING CHASE WALLWATER CLOSET INSTALLATION DETAILNO SCALEOPEN FRONT TOILET SEATCHURCHMODEL 9500CLAVATORY INSTALLATION DETAILNO SCALEFINISHED FLOORHOT SUPPLY STOPCOLD SUPPLY STOP114" P-TRAPSOLENOID VALVE38" PEX TUBING (TYPICAL)WALL-HUNG LAVATORYAMERICAN STANDARD ROXALYNMODEL 0195.073SENSOR ACTIVATEDLAVATORY FAUCETSLOAN MODEL ETF-60012"(MIN)SINGLE PIPE HANGER DETAILSNO SCALEALL-THREAD RODADJUSTABLE BAND HANGERUNINSULATED PIPEALL-THREAD RODADJUSTABLE CLEVIS HANGERUNINSULATED PIPE2" AND SMALLER212" AND LARGERUNINSULATED PIPE-COPPER &STEEL2" AND SMALLER212" AND LARGERINSULATED PIPE-COPPER & STEELALL-THREAD RODADJUSTABLE CLEVIS HANGERPIPEGALVANIZED SHEETMETAL SHIELD-16 GA.(12" LONG)PIPE INSULATIONALL-THREAD RODADJSTABLE STEEL YOKEPIPE ROLL HANGERPIPE INSULATIONPIPEPIPE PROTECTION SADDLE(12" LONG)12" TO 34"1" TO 114"112" TO 2"38"5 FT.38"7 FT.38"8 FT.NOMINAL PIPE SIZEMAX. SPACING212"12"9 FT.3"10 FT.4"58"12 FT.12"6"14 FT.COPPER TUBE HANGER ROD SCHEDULE12"NOTE:CONNECTIONS TO CONCRETEEXPANSION ANCHOR BOLT14" STANDARDCLIP ANGLETHREADED HANGER RODCONCRETE BEAMCONCRETE BEAMCONCRETE SLAB W/METAL DECKSELF-DRILLING ANCHORCONCRETE SLABMETAL DECKLOCKWASHERW/DOUBLE NUTSTHREADED RODCONNECTIONS TO STEELOPEN WEB JOISTSTEEL BEAMSTRUCTURAL STEEL BEAMI-BEAM "C" CLAMPTHREADED RODI-BEAM "C" CLAMPTHREADED RODATTACHMENT DETAILSNO SCALE34"8"16 FT.ALL-THREAD RODUNINSULATED PIPE-PLASTICVEE-BOTTOMCLEVIS HANGERUNINSULATEDPIPE18 GA. GALVANIZEDSUPPORT CHANNEL12" TO 34"1" TO 114"112" TO 2"38"4 FT.38"5 FT.38"6 FT.212" TO 4"12"7 FT.6"8 FT.58"PLASTIC PIPE HANGER ROD SCHEDULE8"9 FT.34"ALL-THREAD RODADJSTABLE STEEL YOKEPIPE ROLL HANGERPIPE INSULATIONPIPEPIPE PROTECTIONSADDLE (12" LONG)INSULATED PIPE-PLASTICPIPE SLEEVE DETAILTO INCLUDE INSULATIONSTEEL PIPE SLEEVE SIZED1/2" PIPE INSULATIONWALLNO SCALEMIXING VALVE SETFOR 110°F MAX.SENSOR CABLECONTROL MODULEESCUTCHEONTRANSFORMER(MTD. ON J-BOX)CEILING18 GA. WIRE (BEHIND WALL)120V POWER(BY E.C.)PIPE SUPPORTS SHALL BE INSTALLED PER MFGR'S. INSTRUCTIONS.NOT MORE THAN 12" FROM ANY CHANGE IN DIRECTION. ADDITIONALLY,SHALL BE INSTALLED NO LESS THAN 10'-0" ON CENTER, ANDMODEL 4-RAH-SS PILLOW BLOCK PIPESTAND. PIPE SUPPORTSNOTE: ROOF PIPE SUPPORT SHALL BE MIRO INDUSTRIESHEIGHT ADJUSTABLE THREADED RODPIPE STRAPSTAINLESS STEEL RODSELF-LUBRICATINGPOLYCARBONATE PIPEROLLERGAS PIPESTAINLESS STEEL BASEROOF GAS PIPE SUPPORT DETAILNO SCALEROOF PENETRATION DETAILNO SCALEROOF DECKINSULATIONCSST GAS TUBINGPREFABRICATED PIPE BOOTSTAINLESS STEEL CLAMPSEALANTSPLICING CEMENTLAP SEALANT(AS REQUIRED)SEISMIC BRACING NOTES:A) THE FOLLOWING SYSTEMS MUST BE BRACED:1) FOR GAS AND ALL PIPING 1" NOMINAL DIAMETER AND LARGER;2) PIPING IN MECHANICAL ROOMS, 1-1/4" IN DIAMETER AND LARGER;3) ALL PIPING 2-1/2" NOMINAL DIAMETER AND LARGER.B) TRANSVERSE AND VERTICAL BRACING SHALL OCCUR AT 40 FT. INTERVALS (MAX) ANDLONGITUDINAL BRACING AT 80 FT. INTERVALS (MAX).C) BRACING IS NOT REQUIRED FOR PIPING SYSTEMS SUSPENDED BY HANGERS 12 IN. OR LESS INLENGTH AS MEASURED FROM THE TOP OF THE PIPE TO THE BOTTOM OF THE SUPPORTWHERE THE HANGER IS ATTACHED.ROD DIAMETERNOMINAL PIPE SIZEMAX. SPACINGROD DIAMETERß" INSULATIONNYLON TIESTIE WRAP7.9"PITCHHEAT TRACE TAPE SUPPLIED & INSTALLED BY R.I.C.THIS DETAIL DOES NOT DEPICT SEISMIC SUPPORTINFORMATION. PROVIDE SEISMIC EQUIPMENTSUPPORT IN ACCORDANCE WITH APPLICABLECODES AND MANUFACTURERS RECOMMENDATIONS.FINAL ELECTRICAL CONNECTION BY THE ELECTRICALCONTRACTOR.1.NOTES:4.2.3.HEAT TRACE CABLE, SELF LIMITING TYPE FOR FREEZEPROTECTION, WITH PARALLEL CONNECTED HEATERZONES, 5 WATT/FT, 120VOLT.INSULATION TO BE SUPPLIED AND INSTALLED BY R.I.C.PVC CONNECTION WITHINTERNAL GROUNDWIREPOWER CONNECTIONHEAT TRACE CABLETO BE WRAPPEDAROUND THE FULLLENGTH OF THE 'P'TRAP.'P' TRAPDRILL OPENING AND SEALTO GFPD CIRCUITBREAKER WITH 30mATRIP SETTING (TYPICALFOR ALL HEAT TRACECIRCUITS).CONDUIT SEALNEMA 4X VAPOR PROOFJUNCTION BOXFLEX CONDUIT (SEE RAYCHEMINSTALLATION GUIDE)CMU WALLEXTERIORPARKING PORT CEILING DECK5.NO SCALE'P' TRAP HEAT TRACE DETAIL FOR COPPER TUBE WHERE HANGER IS IN DIRECT CONTACT WITH BARE PIPE,HANGER SHALL BE PROVIDED WITH NON-METALLIC COATING.HALF-GRATEFLOOR SINK FLOOR LEVEL-NO SLOPE1" LIPNO SCALEFLOOR SINK DETAILBUILDING EXPANSION JOINTFLEXIBLE BRAIDEDPIPEPLAN VIEWNOTE:1. SIZEMIC DEFLECTION LOOP MFG.FLEXICRAFT.2.ALL PIPING MATERIAL SHALL BECOPPER AND / OR STAINLESS STEEL.NO SCALEEXPANSION LOOP DETAIL3" FLEXIBLE OUTLETCONNECTION BY PLUMBINGCONTRACTORROUTE INDEPENDENTLYTO LOCAL FLOOR SINK.PROVIDE MIN. AIR GAP.CLEAR BODY SEDIMENTFILTER WITH INTEGRALBYPASS BY PLUMBINGCONTRACTOR1/2" CW INLET1/2" CWFLEXIBLE SUPPLY CONNECTION BYPLUMBING CONTRACTOR3" MANUAL DRAIN - TYPICAL BYPLUMBING CONTRACTORNOTE:OPERATING LINE PRESSURE 80PSIG, MAX.30 PSIG. MIN.PIPING FOR MAKE-UP WATERLINE AND MANUAL DRAINS BYPLUMBING CONTRACTORBFPPUMP SEAL WATER CONNECTION DIAGRAMNO SCALEWATER HEATER DETAIL (EWH-1)NO SCALEWH1MIXING VALVE, TACO MODEL5000 SERIES (OR EQUAL)P&T RELIEF VALVETHERMOMETER" H.W.(120° F)ELECTRICWATER HEATER(50 GALLONSTORAGE)34" C.W.1" H.W.R.HOT WATER RETURN PUMPB&G CIRCULATING PUMP, MODELNBF-22, 2 GPM @ 14 FT. HD,92 WATTS, 120V, WITH AQUASTATAND TC-1 AUTOMATIC TIMER KIT.(LEAD-FREE BRONZE PUMP BODY)EXPANSION TANKAMTROL MODEL ST-8(OR EQUAL)UNION (TYPICAL)BALL VALVE (TYPICAL)CHECK VALVE (TYPICAL)112" DEEP GALVANIZED STEELDRAIN PAN (MIN. 6" LARGERTHAN WATER HEATER)RUN FULL SIZETO DRAIN18 GAUGE X 24" X 24" X 18" HIGHGALVANIZED WATER HEATER STAND(1300 LB. CAPACITY), IPS MODEL WHS2.FLOORVACUUM BREAKERHEAT TRAP. (MIN. 312")DRAINVALVE34"1"34"AQUASTATSET @ 140°F1BALANCE VALVE80% RETURN TO TEMPERED VALVE20% TO WATER HEATER COLD WATERSIDE.TEST/SETUPCONNECTIONCHECK VALVES WATTS SERIES 73/4" H&CWNOTE:THE GREASE INTERCEPTOR AND FLOW CONTROLFITTING SHALL BE LOCATED IN AN AREA THAT IS READILYACCESSIBLE FOR CLEANING AND INSPECTION.FLOW CONTROL FITTING1-1/2"TO VENTING SYSTEMFLOOR SINK1-1/2"3"GREASEINTERCEPTOR BY P.C.(SEE SCHEDULE)TO SANITARY SYSTEM3-COMPARTMENT SINK INSTALLATION DETAIL1-1/2"2" VFLOOREMPLOYEE SINK INSTALLATION DETAILNO SCALEFINISHED FLOORHOT SUPPLY STOPCOLD SUPPLY STOP114" P-TRAP12" PEX TUBING (TYPICAL)ELKAYCELEBRITYCR2521BREAK ROOM FAUCET12"(MIN)ESCUTCHEONCEILING2 WAY VALVE14" PEX TUBINGWATER FILTERP-200.005 Independence Way, Suite 360Princeton, NJ 08540+1 (609) 751-9655 office+1 (609) 751-9658 faxwww.coolsysenergydesign.comCLIVE SAMUELS07/16/2020CS ENGINEERING FIRM #: 5635830S:\Signatures\Clive Samuels - New York Sign & Sea l.JPG