HomeMy WebLinkAbout20-NJ079_P-001 PLUMBING OVERVIEW SHEET-P-001DRAWINGNUMBERDRAWING TITLEP-001PLUMBING OVERVIEW SHEETP-400PLUMBING RISER DIAGRAMSP-200PLUMBING DETAILSP-300PLUMBING SPECIFICATIONS1.DO NOT SCALE FROM THESE DRAWINGS.2.DO NOT MAKE ANY CHANGES OR SUBSTITUTIONS WITHOUT SPECIFIC WRITTEN APPROVAL FROM THE ARCHITECT OR ENGINEER.3.ALL INDICATED WORK SHALL BE PERFORMED BY THE PLUMBING CONTRACTOR UNLESS OTHERWISE NOTED.4.ALL DOMESTIC WATER FIXTURES, VALVES, AND BFP'S SHALL BE LEAD-FREE IN ACCORDANCE WITH NATIONAL CODES.5.REFER TO THE WRITTEN SPECIFICATIONS IN CONJUNCTION WITH THE PLANS FOR FULL PROJECT SCOPE. IT IS THE RESPONSIBILITY OF THEPLUMBING CONTRACTOR TO REVIEW THESE PLANS AND SPECIFICATIONS, AS WELL AS THE RELATED HVAC, FIRE PROTECTION, ELECTRICAL,STRUCTURAL, ARCHITECTURAL, INTERIOR DECOR AND SITE ENGINEERING DRAWING TO BECOME FAMILIAR WITH THE FULL PROJECT SCOPE. INADDITION, THIS CONTRACTOR MUST COORDINATE WITH A TENANT REPRESENTATIVE TO FULLY UNDERSTAND ALL REQUIREMENTS WHICH MAYNOT BE SPECIFIED HEREIN AND WHICH THE TENANT MAY CONSIDER PART OF THIS CONTRACT. DURING THE COURSE OF CONSTRUCTIONCOORDINATION AND ACTUAL CONSTRUCTION, IT IS THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO WORK CLOSELY WITH ALLACCOMPANYING CONTRACTORS AND TRADESMEN IN ORDER TO ENSURE A SMOOTH RUNNING AND CAREFULLY COORDINATED INSTALLATION.ANY DISCREPANCIES OR INADEQUACIES WITHIN THESE BID DOCUMENTS OR DISCREPANCIES BETWEEN THESE BID DOCUMENTS AND THERELATED HVAC, FIRE PROTECTION, ELECTRICAL, STRUCTURAL,ARCHITECTURAL, INTERIOR DECOR AND SITE ENGINEERING DRAWINGS, ORBETWEEN THESE BID DOCUMENTS AND FIELD CONDITIONS MUST BE BROUGHT TO THE ATTENTION OF THE TENANT, ARCHITECT AND ENGINEERPRIOR TO BID SUBMISSION.6.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE REGULATIONS INCLUDING BUT NOT LIMITED TO NATIONAL, CITY, STATE,LOCAL CODES AND ORDINANCES WHICH MAY BE IN EFFECT. ALL PLUMBING MATERIALS, INSTALLATION PROCEDURES AND SYSTEM LAYOUTSSHALL BE APPROVED BY ALL APPLICABLE CODE ENFORCEMENT AUTHORITIES HAVING JURISDICTION, AND IT SHALL BE THE PLUMBINGCONTRACTOR'S RESPONSIBILITY TO OBTAIN AND PAY FOR ALL NECESSARY PERMITS AND APPROVALS FOR THIS INSTALLATION.7.THE PLUMBING CONTRACTOR SHALL PROVIDE A COMPLETE SET OF RECORD "AS-BUILT" DRAWINGS INDICATING THE PRECISE LOCATION OF ALLSYSTEMS, EQUIPMENT CONCEALED OR EMBEDDED PIPING, PIPING CONNECTIONS AND ACCESS DOORS. THESE DRAWINGS SHALL ALSO INCLUDEALL CHANGES AND DEVIATIONS FROM BID DOCUMENTS.8.RUN ALL DOMESTIC WATER, WASTE, VENT AND GAS PIPING AS HIGH AS POSSIBLE THROUGHOUT ENTIRE BUILDING. INSTALL LONG RUNS OFPIPING WITHIN STEEL (JOIST) SPACE AND OTHER PIPING TIGHT TO BOTTOM OF STEEL. COORDINATE AND VERIFY WITH OTHER CONTRACTORSAS NOT TO INTERFERE WITH DUCTWORK, FIRE PROTECTION PIPING, LIGHTING SYSTEMS, ETC.9.ALL EXPOSED HORIZONTAL AND VERTICAL PIPING SHALL BE INSTALLED IN A NEAT ARRANGEMENT IN LOCATIONS WHICH ARE THE MOSTINCONSPICUOUS. VERTICAL DROPS SHALL BE KEPT TO AN ABSOLUTE MINIMUM AND THEIR FINAL LOCATIONS SHALL BE COORDINATED AND RUNWITHIN CHASES, WALLS, SOFFITS WITH OTHER MECHANICAL / ELECTRICAL FEEDS. ALL SUCH LOCATIONS ARE TO BE REVIEWED WITH A TENANTREPRESENTATIVE AND ARCHITECT PRIOR TO INSTALLATION. FINAL CONNECTIONS TO ALL GAS FIRED APPLIANCES TO BE BY THE PLUMBINGCONTRACTOR.10.FINAL CONNECTIONS TO GAS-FIRED EQUIPMENT SHALL BE MADE BY THE PLUMBING CONTRACTOR, REGARDLESS OF WHO PROVIDES APPLIANCE.THIS SHALL INCLUDE BUT NOT BE LIMITED TO HVAC EQUIPMENT, COOKING EQUIPMENT, EMERGENCY GENERATORS AND DOMESTIC HOT WATERHEATERS. EACH PIECE OF EQUIPMENT SHALL BE PROVIDED WITH A DIRT LEG, LUBRICATED PLUG VALVE, UNION AND GAS SHUT-OFF VALVE.11.ALL PLUMBING FIXTURES / APPLIANCES SHALL HAVE THEIR OWN INDEPENDENT SHUT-OFF VALVES, INSTALLED IN AN EASILY ACCESSIBLE ANDCONVENIENT LOCATION.12.ALL DOMESTIC WATER BRANCH LINES SHALL HAVE THEIR OWN RESPECTIVE SHUT-OFF VALVES.13.DOMESTIC HOT WATER HEATER TEMPERATURE / PRESSURE RELIEF VALVES SHALL BE PIPED FULL SIZE TO THE NEAREST APPROVED STANDPIPEOR FLOOR DRAIN. THIS REQUIREMENT SHALL BE APPLICABLE TO ALL DOMESTIC WATER HEATERS EXCEPT INSTANTANEOUS WATER HEATERS.14.ALL LAVATORY HAND SINKS SHALL HAVE IN-LINE WATER TEMPERING VALVES INSTALLED SO AS TO BE EASILY ACCESSIBLE. THESE TEMPERINGVALVES SHALL BE SET TO DELIVER HOT WATER AT 105° F.15.ALL PLUMBING VENT LINES NOTED AS "V. UP" OR "VENT UP" SHALL BE CONNECTED TO THE NEAREST APPROVED "V.T.R." OR "VENT THRU ROOF."16.WHERE APPLICABLE, DO NOT RUN VENTS THROUGH ROOF AT PRE-FINISH METAL ROOFING SYSTEMS, INSTEAD DIVERT VENT PIPING TO RUN UPTHROUGH FLAT MEMBRANE ROOF. VENTS THROUGH ROOF SHALL NOT BE VISIBLE TO STORE CLIENTELE. VENTS THROUGH THE ROOF SHALLTERMINATE A MINIMUM OF 10'-0" FROM ALL FRESH AIR INTAKES, COORDINATE EXACT LOCATION WITH MECHANICAL DRAWING.17.THE PLUMBING CONTRACTOR SHALL RUN OUT ALL BUILDING DRAINAGE AND WASTE LINES AND MAKE ALL CONNECTIONS TO SITE LEVEL SYSTEMSAS INDICATED ON BID DOCUMENTS.18.COORDINATE ALL APPLIANCE / FIXTURE SCHEDULE I.D. NUMBERS WITH THE ARCHITECTURAL DRAWINGS FOR THE EXACT QUANTITY ANDLOCATIONS.19.ALL EQUIPMENT WITH DIRECT CONNECTIONS TO THE DOMESTIC WATER SYSTEM SHALL BE EQUIPPED WITH WATTS, No.7 DUAL CHECK VALVEBACKFLOW PREVENTION DEVICE.20.ALL FLOOR DRAINS IN MECHANICAL ROOMS AND BATHROOM SHALL BE EQUIPPED WITH AUTOMATIC TRAP PRIMERS.21.CROSS CONNECTION PROTECTION SHALL BE PROVIDED AT ALL POTABLE WATER SUPPLIED APPLIANCES AND EQUIPMENT.22.VENTING BELOW FINISHED FLOOR SHALL BE SLOPED BACK TO THE DRAINAGE PIPE AT 1/8" PER FOOT AND SHALL NEVER BE BELOW THE TRAPWEIR OF THE FIXTURE IT IS SERVING. MINIMUM SIZE FOR VENTS BELOW GRADE SHALL BE 2".23.CONDENSATE LINES SHALL BE PITCHED AT NO LESS THAN 1/8" PER FOOT.12OCCUPANCY TYPEGOVERNING CODES& REGULATIONSMERCHANTILESANITARY PIPECDGSANCWVCOMBINATION WASTE & VENT PIPEVENT PIPECOLD WATER SUPPLY PIPEHOT WATER SUPPLY PIPEHOT WATER RETURN PIPEGAS PIPECONDENSATE PIPEFLOOR CLEAN OUTFLOOR SINKFLOOR DRAINPIPE RISE OR DROPWATER SHUTOFF VALVECIRCULATION PUMPGAS VALVEUNIONAFFABOVE FINISHED FLOORBFFBELOW FINISHED FLOORCONNECT TO EXISTING. CONTRACTOR TO FIELD VERIFY EXACT LOCATION OF EXISTINGFIXTURE/EQUIPMENT/PIPE AND PROVIDE NECESSARY OFFSETS, FITTINGS AND MATERIALS AT NOADDITIONAL COST TO THE TENANT. COORDINATE ALL INVERTS AND LOCATIONS WITH SHELLDRAWINGS.VCWHWHWRV(E)SAN(E)EXISTING HOT WATER SUPPLY PIPEEXISTING COLD HOT WATER RETURNEXISTING SANITARYEXISTING VENTHW(E)CW(E)CODES & REGULATIONSDRAWING INDEXSYMBOLS AND ABBREVIATIONSPLUMBING GENERAL NOTESNOTES:CONTRACTOR SHALL FURNISH AND INSTALL BACKFLOW PREVENTION DEVICES AT THE EQUIPMENT LISTED ABOVE.DEVICES LISTED ARE MANUFACTURED BY WATTS REGULATOR COMPANY. CONTRACTOR MAY SUBMIT AN EQUAL FROM ANOTHER MANUFACTURER FORREVIEW.CONTRACTOR TO VERIFY REQUIREMENTS WITH LOCAL AUTHORITIES HAVING JURISDICTION.FURNISHED WITH AN INTEGRAL VACUUM BREAKERFURNISHED WITH INTEGRAL BACKFLOW PREVENTER AND VACUUMBREAKER PORT.3.WALL HYDRANTS, HOSE BIBB, WASH DOWN FAUCETTRAP PRIMER2.1.FAUCET FURNISHED WITH AN INTEGRAL VACUUMBREAKERFLUSH VALVE FURNISHED WITH AN INTEGRALVACUUM BREAKERBACKFLOWPREVENTION DEVICEDRINKING FOUNTAIN / ELECTRIC WATER COOLERSERVICE / MOP SINKS / EYE WASHHAND WASHING SINKS / LAVATORIESWATER CLOSETFIXTUREAIR GAPAIR GAPP-100PLUMBING FLOOR PLANIN °FTEMPERATUREDESIG.@ 100°F RISERECOVERY GPHSERVICEDOMESTICGALLONSCAPACITYSTORAGEMANUFACTURER & MODEL NO.STATE - SSE-50AELECTRIC ELEMENT(S)WATTSOUT °FVOLTS/PHASE208/3WATER HEATER SCHEDULEEWH-1NOTESNSF APPROVED.FURNISH WITH P&T RELIEF VALVE.615015,000140 40 HUB DRAIN2020 BUILDING CODE OF NEW YORK STATEMARKP-2P-4P-5P-7P-8P-9P-10TYPEWALL HUNGLAVATORYFLOOR SINKSERVICE SINKHAND SINK3-COMPARTMENTSINKEMPLOYEE SINKFLOOR SINKDRINKINGFOUNTAINQTY.WASTEVENTCWHWMANUFACTURER/MODELREMARKS311111112"3"3"2"2"2"2"2"1-1/2"2"2"1-1/2"1-1/2"1-1/2"1-1/2"1-1/2"1/2"1/2"--1/2"1/2"1/2"1/2"3/4"3/4"1/2"1/2"--1/2"-AMERICAN STANDARD / LUCERNE 0356.421AMERICAN STANDARD / 6053.105FLORESTONE/ MSR-3624FLORESTONE / MSR-2424FLORESTONE / MR-371FLORESTONE / MR-372ZURN / Z1341ELKAY / EHS-14XELKAY / 3C12X16-2-16XELKAY / CELEBRITY CR2521SYMMONS / SYMMETRIX S-245-5-LWGJR SMITH / 3002HALSEY TAYLOR / HTVZ8BLV-NFVITREOUS CHINA, COLOR WHITE W/ 0.5 GPM BATTERY POWER SENSOR FAUCET, GRID STRAINER DRAIN ASSEMBLY, POLISHED CHROME FINISH, ANDPROFLOW-PFGD101 OFFEST LAVATORY GRID DRAIN & SUPPLY STOPS, CONCEALED ARM SUPPORTS. PROVIDE PIPE PROTECTION TO COMPLY WITHADA AND ANSI A117.1 GUIDELINES. PROVIDE AND INSTALL MV-1. PROVIDE PFTSCOF2000WH COMMERCIAL TOILET SEAT. FURNISHED BY TENANT,INSTALLED BY PLUMBING CONTRACTOR.MOLDED MOP RECEPTOR, ONE PIECE WITH RIBBED UNDERBODY AND INTEGRAL DRAIN FOR 3" ABS PIPE, AND 18 GAUGE STAINLESS STEEL, FLATTYPE #430 DRAIN GRID. (BASIN AND DRAIN FOR CONDENSATE DISPOSAL ONLY)MOLDED MOP RECEPTOR, ONE PIECE WITH RIBBED UNDERBODY AND INTEGRAL DRAIN FOR 3" ABS PIPE, AND 18 GAUGE STAINLESS STEEL, FLATTYPE #430 DRAIN GRID. PROVIDE WITH SPEAKMAN FAUCET WITH INTEGRAL VACUUM BREAKER., DOUBLE STOPS, PAIL HOOK, HOSE THREAD SPOUTAND BRACE, MOP HANGER AND INDEPENDENT HOSE BIBB.STAINLESS STEEL HAND SINK WITH SPLASH MOUNT, GOOSENECK FAUCET (INCLUDED) AND BASKET STRAINER (INCLUDED). NSFAPPROVED. FURNISH AND INSTALL MV-1.SINK FURNISHED BY TENANT, INSTALLED BY PLUMBING CONTRACTOR.STAINLESS STEEL 3-COMPARTMENT SINK WITH PRE-RINSE UNIT AND SPRAY VALVE, WALL MOUNT.NSF APPROVED. PROVIDE PERMADRAIN DRAINSHIELD.FURNISHED BY TENANT, INSTALLED BY PLUMBING CONTRACTOR.SELF-RIMMING #18 GAUGE TYPE 304 STAINLESS STEEL, SINGLE BOWL SINK, 3-HOLES, WITH GOOSENECK FAUCET AND 2-WRIST BLADE HANDLES,BASKET TYPE STRAINER, POLISHED CHROME P-TRAP & SUPPLY STOPS. PROVIDE PIPE PROTECTION TO COMPLY WITH ADA AND ANSI A117.1GUIDELINES. INSTALL WF-1 UNDERNEATH SINK.FLOOR SINK WITH 12" STAINLESS STEEL TOP, 1/2 GRATE AND PERMADRAIN LOCKING DOME STRAINER KIT & SAFETY BASKET.BI-LEVEL SELF-CONTAINED REFRIGERATED WATER COOLER, BARRIER FREE. 120V.ADA COMPLIANT. FURNISHED BY TENANT, INSTALLED BY PLUMBING CONTRACTOR.BFPRPZ BACKFLOWPREVENTER2WATER HAMMERARRESTORSEE PLAN-------WATTS / LF-009MIFAB MWH OR EQUALINSTALL AT READILY ACCESSIBLE LOCATION WITH ACCESS PANEL.PLUMBING FIXTURE/EQUIPMENT SCHEDULEWHAFCOCP-1TP-1CIRCULATINGPUMP1----B&G / NBF-22FLOOR CLEAN-OUT---JAY R. SMITH / 4220ROUND CAST IRON TOP TRACTOR COVER WITH SET SCREW AND GASKETED COVER.CIRCULATING PUMP, 2GPM @ 14 FT. HD., 92 WATTS, 120V, WITH AQUASTAT AND TC-1 AUTOMATIC TIMER KIT, LEAD-FREE BRONZE PUMP BODY WITHPLUG-IN CORD.TRAP PRIMER----PRECISION PLUMBING PRODUCTS / PR-500INSTALL PRIMING VALVE A MINIMUM OF 12" ABOVE FINISHED FLOOR, INSTALL ON COLD WATER LINE OF 1-1/2" OR LESS. INSTALL WITH SERVICEVALVE AND ACCESS PANEL.3MV-1MIXING VALVE4--1/2"1/2"POWERS / E480NPT CONNECTION, FACTORY SET AT 105°F, IN-LINE TYPE, LOCATED AT ALL HAND WASHING SINKS AND LAVATORIESP-11-P-1HANDICAPPEDFLUSH VALVEWATER CLOSET34"2"1 1/2"-AMERICAN STANDARD / AFWALL 2257.101SLOAN / UPPERCUT WES-111CHURCH / 9500CWATTS / ISCA-141 WALL CLOSET CARRIERWALL MOUNTED, VITREOUS CHINA, COLOR WHITE, ELONGATED FRONT, HANDICAPPED HEIGHT, TOP SPUD FLUSH VALVE, ELONGATED OPEN FRONTTOILET SEAT. WATTS THIN WALL CLOSET CARRIER. FURNISHED BY TENANT, INSTALLED BY PLUMBING CONTRACTOR.FPWH FREEZELESSWALL HYDRANT3/4"---WOODFORDBRASS NOZZLE, HOSE CONNECTION BFP, INCLUDE MOUNTING SYSTEM WITH HYDRANT BOOT SEAL. TO BE PROVIDED BY LANDLORD.FD-1FLOOR DRAINJAY R. SMITH / 2010-B-P050-BBPOLISHED BRONZE. PROVIDE PERMADRAIN CROSS-STRAINER.3"--SEE PLAN-GREASE TRAP13"2"--SCHIER / GB-2GREASE INTERCEPTOR, 35 GPM, 130.5 LBS. GREASE CAPACITY. GREASE INTERCEPTOR TO BE RECESSED, SEE DETAIL ON P-200 FOR MOREINFORMATION.P-6FS-1FLOOR SINK4"--0-ZURN / ZS1900-HD-VPS-3-11-23-31EW-1EYE WASH2"--1-N/ATRADER JOE'S TO PROVIDE EYE WASHELKAY / SLK945GN08T4T (FAUCET)2020 MECHANICAL CODE OF NEW YORK STATEFURNISHED WITH AN INTEGRAL VACUUM BREAKERCOMPARTMENT SINK2020 PLUMBING CODE OF NEW YORK STATE2020 FUEL GAS CODE OF NEW YORK STATE2020 EXISTING BUILDING CODE OFNEW YORK STATETRADER JOE'S TO PROVIDE WATER FILTER. INSTALLED BY PLUMBING CONTRACTOR.N/AWF-1-1/4"-WATER FILTER1-CB-1CATCH BASINZURN / Z887-24CATCH BASIN TO BE ENCASED IN 4" THICK CONCRETE.4"--1-SEE PLANSEE PLANSEE PLANSEE PLANP-101PLUMBING ROOF PLANREQUIRED PLUMBING FIXTURE PER OCCUPANCYMERCHANTILE / MTOTAL OCCUPANCY173 PEOPLECLASSIFICATION /OCCUPANCYWATER CLOSETSMALEFEMALELAVATORIESMALEFEMALEDRINKINGFOUNTAINSMALEFEMALEOTHERMALEFEMALE1 PER 500PEOPLE1 PER 750PEOPLE1 PER 1000PEOPLE1 SERVICE SINKNUMBERS BASED OFF 2015 NEW YORK STATE PLUMBING CODE SECTION 403.1P-001.001 06/29/2020 COORDINATION REVISIONS 5 Independence Way, Suite 360Princeton, NJ 08540+1 (609) 751-9655 office+1 (609) 751-9658 faxwww.coolsysenergydesign.comCLIVE SAMUELS07/16/2020CS ENGINEERING FIRM #: 5635830S:\Signatures\Clive Samuels - New York Sign & Sea l.JPG 2 07/16/2020 REVISED PER BUILDING DEPARTMENT COMMENTS