HomeMy WebLinkAbout20-NJ079_M-100 HVAC FLOOR PLAN-M100CPLPPPRP150KVAMDPSDP30"48"36"SAFEST-1ST-2ST-3(2)EG-1 6"x6"75 CFMEG-1 6"x6"75 CFMAH1RTU1RTU2RTU3RTU4CD-2 12"Ø625 CFMCD-1 12"Ø625 CFMCD-1 12"Ø625 CFMCD-1 12"Ø625 CFMCD-1 12"Ø625 CFMCD-1 12"Ø625 CFMCD-1 12"Ø625 CFMCD-1 8"Ø300 CFMCD-1 8"Ø325 CFMCD-1 12"Ø625 CFMCD-1 12"Ø625 CFMCD-1 12"Ø625 CFMCD-1 12"Ø625 CFMCD-1 12"Ø625 CFMCD-1 12"Ø625 CFMCD-1 12"Ø625 CFMCD-1 12"Ø625 CFMCD-1 14"Ø675 CFMCD-3 6"Ø100 CFMCD-3 6"Ø100 CFMCD-2 8"Ø325 CFMCD-2 12"Ø650 CFMCD-2 8"Ø325 CFMCD-2 8"Ø325 CFM12"Ø14"X14"16"X16"12"Ø14"X14"
22"X20"28"X20"14"X14"12"Ø 16"X16"22"X18"
16"X16"12"X10"28"X20"CD-1 14"Ø675 CFMCD-1 14"Ø675 CFMCD-1 14"Ø675 CFM14"X14"14"Ø20"X16"14"Ø
10"X10"(2)TG-1 10x10325 CFM8"Ø12"Ø14"X12"16"X14"8"X10"12"X12"
1
6
"X
1
4
"CD-2 8"Ø275 CFM(2)CD-3 6"Ø50 CFM6"X8"6"Ø8"X6"SRTU-2HSSRTU-3HSSRTU-4HS30"X20"
30"X20"
26"X16"SDSDSDSDTG-28"X8"CD-2 12"Ø650 CFM6"X6"10"X8"CD-3 6"Ø50 CFM6"ØTEF-26"X6"SR-1 10"x3"100 CFMM-100.001.2.STRGCDMECHANICAL SYMBOL LISTA.THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERALEXTENT OF THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FORTHE COORDINATION AND PROPER INSTALLATION OF ALL MECHANICALSYSTEMS. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY OFFSETSAND FITTINGS WHICH MAY BE REQUIRED DUE TO SPACE CONSTRAINTS OROTHER CONDITIONSB.THE CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS SUPPORTINGSTEEL, ETC. FOR THE PROPER INSTALLATION OF ALL MECHANICALSYSTEMS.C.THE CONTRACTOR SHALL COORDINATE FLOOR, WALL AND ROOFPENETRATIONS, LOUVER SIZES, ETC. WITH GENERAL TRADES.D.THE CONTRACTOR SHALL VERIFY ALL CLEARANCES PRIOR TO FABRICATIONOF ANY WORK.E.THE CONTRACTOR SHALL COORDINATE THE LOCATION OF CEILING GRILLES,REGISTERS AND DIFFUSERS WITH THE ARCHITECTURAL REFLECTEDCEILING PLANS.F.DUCTWORK SHALL NOT BE LOCATED OVER THE TOP OF ANY ELECTRICALPANELS OR EQUIPMENT.G.THE CONTRACTOR SHALL COORDINATE AND PROVIDE ACCESS DOORS INHARD CEILINGS FOR ALL EQUIPMENT WHICH REQUIRES ACCESS, SUCH AS:FIRE AND SMOKE DAMPERS, SMOKE DETECTORS, BALANCING DAMPERS,ETC., WHETHER SHOWN ON THE PLAN OR NOT.H.THE INFORMATION ON THIS PLAN IS INCLUDED FOR REFERENCE ONLY. THECONTRACTOR SHALL BE HELD RESPONSIBLE TO HAVE VISITED THE SITEPRIOR TO SUBMITTING HIS ESTIMATE AND TO HAVE EXAMINED ANDFAMILIARIZED HIMSELF WITH THE SITE CONDITIONS OF THE PROJECT. HESHALL COMPARE THE DRAWINGS AND SPECIFICATIONS WITH THE RESULTSOF HIS EXAMINATION OF THE SITE AND GENERALLY VERIFY THE LOCATIONOF ALL EXISTING WORK, AND BECOME INFORMED AS TO THE RELATION TOAND AFFECT ON THE WORK REQUIRED, BEFORE SUBMITTING A BID.SUBMISSION OF A BID WILL CONSTITUTE EVIDENCE THAT THE CONTRACTORHAS INSPECTED THE SITE OF THE PROPOSED WORK AND NO EXTRAPAYMENT WILL BE ALLOWED TO THE CONTRACTOR BECAUSE OFUNFAMILIARITY WITH THE SITE CONDITIONS.I.IT IS NOT INTENDED THAT THE DRAWINGS SHALL SHOW ALL DETAILS OFCONSTRUCTION, HOWEVER, THE H.V.A.C. SUBCONTRACTOR SHALL BEREQUIRED TO FURNISH AND INSTALL ALL MATERIALS NECESSARY TOCOMPLETE THE H.V.A.C. SYSTEM IN ACCORDANCE WITH THE BESTPRACTICE AND TO THE FULL EXTENT OF THE DRAWINGS ANDSPECIFICATIONS. THE H.V.A.C. SUBCONTRACTOR SHALL FURNISH ANDINSTALL ALL PARTS WHICH MAY BE REQUIRED BY THE DRAWINGS ANDOMITTED BY THE SPECIFICATIONS, OR VICE VERSA, JUST AS THOSEREQUIRED BY BOTH. SHOULD THERE APPEAR TO BE DISCREPANCIES OR AQUESTION OF INTENT, THE H.V.A.C. CONTRACTOR SHALL REFER TO THEARCHITECT/ENGINEER FOR DECISIONS, FURTHERMORE, HISINTERPRETATION SHALL BE FINAL, CONCLUSIVE AND BINDING.J.WITH THE SUBMISSION OF BID, THE H.V.A.C. CONTRACTOR SHALL HAVEAGREED TO HAVE INCLUDED THE COST OF ALL REQUIRED ITEMS IN HISPROPOSAL AND THAT HE WILL BE HELD RESPONSIBLE FOR THE APPROVEDSATISFACTORY FUNCTIONING FOR THE ENTIRE SYSTEM WITHOUT EXTRACOMPENSATION.COGENERAL NOTES1.OUTLINE OF ROOF TOP UNIT, FURNISHED AND INSTALLED BYLANDLORD.2.MOUNT COMBO SENSOR 66" A.F.F. COORDINATE EXACT LOCATIONWITH EMS CONTRACTOR.3.CONNECT SUPPLY AND RETURN DUCT TO EXISTING SUPPLY ANDRETURN DUCT PROVIDED BY LANDLORD, PROVIDE 1"INTERNALLY LINED IN SUPPLY AND RETURN DUCT UP TO 12 FEETFROM UNIT CONNECTION POINT.4.ADDRESSABLE SMOKE DETECTOR IN RETURN AIR DUCT TO SHUTDOWN UNIT UPON SMOKE DETECTION, FURNISHED ANDINSTALLED BY LANDLORD.5.MECHANICAL CONTRACTOR TO FURNISH AND INSTALL AIR-ROWLA-248 CEILING DIFFUSER FAN (CDF). INTERLOCK CDF-1, 2 & 3WITH TEMP SENSOR T-1. INSTALL PER MANUFACTURESSPECIFICATIONS.6.MECHANICAL CONTRACTOR TO FURNISH AND INSTALL AIR-ROWLA-248 CEILING DIFFUSER FAN (CDF). INTERLOCK CDF-4, 5, 6, 7, &8 WITH TEMP SENSOR T-2 INSTALL PER MANUFACTURESSPECIFICATIONS.7.MECHANICAL CONTRACTOR TO FURNISH AND INSTALL AIR-ROWLA-248 CEILING DIFFUSER FAN (CDF). INTERLOCK CDF-9, 10, 11,` &12 WITH TEMP SENSOR T-3 INSTALL PER MANUFACTURESSPECIFICATIONS.8.LOCATE TEMP SENSOR ON CEILING.9.MOUNT AIR CURTAIN ABOVE VESTIBULE DOORS. VERIFYLOCATION WITH ARCHITECTURAL PLAN. INSTALL PERMANUFACTURERS SPECIFICATIONS.10.MOUNT AIR CURTAIN ABOVE LOADING DOCK DOOR. VERIFYLOCATION WITH ARCHITECTURAL PLAN. INSTALL PERMANUFACTURERS SPECIFICATIONS.11.8"x8" EXHAUST DUCT UP THRU CEILING TO EXHAUST FAN ONROOF.12.MOUNT TEMP SENSOR 66" A.F.F13.REFRIGERANT PIPING DOWN FROM CONDENSING UNIT CU-1 ONROOF.14.CONNECT 26"x14" SUPPLY AND 26"x16" RETURN DUCT UP TOEXISTING SUPPLY AND RETURN DUCT PROVIDED BY LANDLORDUP TO RTU-1 ON ROOF. PROVIDE TRANSITION AS REQUIRED.15.CONNECT 28"x20" SUPPLY AND 30"x20" RETURN DUCT UP TOEXISTING SUPPLY AND RETURN DUCT PROVIDED BY LANDLORDUP TO RTU-2 ON ROOF. PROVIDE TRANSITION AS REQUIRED.16.CONNECT 28"x20" SUPPLY AND 30"x20" RETURN DUCT UP TOEXISTING SUPPLY AND RETURN DUCT PROVIDED BY LANDLORDUP TO RTU-3 ON ROOF. PROVIDE TRANSITION AS REQUIRED.17.CONNECT 26"x14" SUPPLY AND 26"x16" RETURN DUCT UP TOEXISTING SUPPLY AND RETURN DUCT PROVIDED BY LANDLORDUP TO RTU-4 ON ROOF. PROVIDE TRANSITION AS REQUIRED.18.8" EXHAUST DUCT THRU ROOF. TERMINATE WITH GOOSENECK19.REFER TO HVAC PLATFORM FOR CONTINUATION OF DUCTWORK.20.10"X8" SUPPLY DUCT DOWN TO SUPPLY DIFFUSER IN THE BREAKROOM. PROVIDE TRANSITIONS AS REQUIRED.21.10"X8" SUPPLY DUCT DROP ABOVE BREAK ROOM CEILING.22.REFER TO HVAC FLOOR PLAN FOR CONTINUATION OF DUCTWORK.MECHANICAL KEY NOTES -TSHS·NO MECHANICAL SYSTEMS SHALL BE INSTALLEDWITHOUT COMPLETELY COORDINATED ANDAPPROVED BY THE ARCHITECT / ENGINEER SHOPDRAWINGS TO PREVENT ANY INSTALLATIONCLASHES / CONFLICTS.·FAILURE TO PRODUCE THIS COORDINATED SHOPDRAWING SHALL BE AT THE SOLE RISK ANDEXPENSE OF THE CONTRACTORS. EXTRACOMPENSATION WILL NOT BE PROVIDED DUE TO ALACK OF A COORDINATED SHOP DRAWING.MECHANICAL SYSTEM INSTALLATION NOTE:5 Independence Way, Suite 360Princeton, NJ 08540+1 (609) 751-9655 office+1 (609) 751-9658 faxwww.coolsysenergydesign.comCLIVE SAMUELS07/16/2020CS ENGINEERING FIRM #: 5635830S:\Signatures\Clive Samuels - New York Sign & Sea
l.JPG
2 07/16/2020 REVISED PER BUILDING DEPARTMENT COMMENTS