HomeMy WebLinkAboutPhase 5 Low Rise 6 Interior Modifications_DrawingsPHASE 5 LOW RISE 6 INTERIOR MODIFICATIONS237 JESSUP ROAD, ITHACA, NEW YORK 14850CORNELL UNIVERSITYITHACA, NY 14850LOW RISE 6SEALPRIME CONSULTANT59-61 Court Street Suite 300,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comSHEET NUMBER114475IBI PROJECT NO:CLIENT PROJECT NO:--DATE:2019-11-20PHASE 5 LOW RISE 6 INTERIOR
MODIFICATIONS
237 JESSUP ROAD, ITHACA, NEW YORK 14850
CORNELL UNIVERSITY
LOW RISE 6 ARCHITECT/ ENGINEER:CONSULTANTS:118949IBI PROJECT NO:IBI GROUPARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTS59-61 COURT STREET SUITE 300BINGHAMTON, NY 13901, USATEL: 607-772-0007, FAX: 607-723-4121ibigroup.comLOCATION MAP:G000ITHACA, NY 14850 LOW RISE 6:ARCHITECTURAL:LR6-A000-BASEMENT LEVEL 1 AND 2 CODE COMPLIANCE PLANLR6-A001-LEVEL 3 AND 4 CODE COMPLIANCE PLANLR6-A002-DOOR SCHEDULE DETAILS AND WALL PARTITIONSLR6-A003-DOOR DETAILSLR6-A004-ADA COMPLIANCE ABBREVIATIONS AND SYMBOLS KEYLR6-A100-LEVEL 1 AND 2 OVERALL FLOOR PLANLR6-A101-LEVEL 3 AND 4 OVERALL FLOOR PLANLR6-A102 ENLARGED FLOOR PLANSLR6-A103-ENLARGED FLOOR PLANS AND DETAILSLR6-A104-CEILING DETAILSLR6-A300-DUMBWAITER SHAFT PLANS AND SECTIONSHAZARDOUS MATERIALS:LR6-HM100 LEVEL 1 AND 2 HAZARDOUS MATERIALS PLANLR6-HM101 LEVEL 3 AND 4 HAZARDOUS MATERIALS PLANDRAWING LIST6
62646263626262526200TD6200TC625362546200CE6200CD626162516214621362126200TF6200TE6224622362226200CG6200CF621162216234623362326200CB6200TB6200TA62446200CA6243624262416200CC6231620662036200JA62026200EA6200JB6200CH6200CM620762086200CJ620962106200L6200EB6200CK610261216100CE6100CD61036100J61066100CC61116112611361146100TC6100TD612261236124614161316100CB6100CA6100TA6100TB61326133613461446143614261616100CG6100CF61516152615361546164616361626100TE6100TFUPDNDNUPUPDNUPDNUPUPDNUPDNUPUPDNUPDNDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORKITCHENKITCHENJANITORCLOSETJANITORCLOSETCORRIDORVESTIBULEOFFICEMECHANICALMECHANICALVESTIBULELOUNGELOUNGEOFFICETOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETCORRIDORCORRIDOR6200SBSTAIR 26200SASTAIR A6100SASTAIR B6100SDFIREESCAPE 46200SDFIREESCAPE 36100SCSTAIR 16100SFFIREESCAPE 16100SEFIREESCAPE 16100SBSTAIR 16200SCSTAIR 26200SFFIREESCAPE 16200SEFIREESCAPE 26B016B01A6B036B00U6B00EB6B046B00C6B026B00TB6B00TA6B00EAUPUPTOILETTOILETCORRIDORMECHANICALMECHANICALSTORAGESTORAGESTORAGELAUNDRY6B00SBSTAIR B6B00SBSTAIR 36B00SASTAIR ADATE:ISSUESHEET TITLEPROJECTPHASE 5LOWRISE 6 INTERIORMODIFICATIONS1ISSUED FOR BID2019-03-12SCALE:APPROVED BY:PROJECT MGR:IBI PROJECT NO:SHEET NUMBER237 JESSUP ROAD, ITHACA, NEW YORK 14850PRIME CONSULTANTCLIENTCOPYRIGHTISSUESCORNELLUNIVERSITYThis drawing has been prepared solely for the intended use, thus anyreproduction or distribution for any purpose other than authorized by IBI Group isforbidden. Written dimensions shall have precedence over scaled dimensions.Contractors shall verify and be responsible for all dimensions and conditions onthe job, and IBI Group shall be informed of any variations from the dimensions andconditions shown on the drawing. Shop drawings shall be submitted to IBI Groupfor general conformance before proceeding with fabrication.is a member of the IBI Group of companiesIBI GROUP ARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTSKEYPLANCHECKED BY:DRAWN BY:SCALE CHECK CONSULTANTSSEAL10mm1 in 59-61 Court Street,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comCLIENT PROJECT NO:ITHACA, NEW YORK 14850LOWRISE 6 AND 9IMPROVEMENTS ANDCODE REMEDIATION114475 11412AS NOTED2019-11-20PLANNORTHBASEMENT, LEVEL 1 AND 2CODE COMPLIANCE PLANLR6-A000 A3/32" = 1' - 0"FIRST AND SECOND LEVEL PLAN13/32" = 1' - 0"BASEMENT LEVEL PLAN2PLANNORTHPLANNORTHUNIT 2 - SUITE 6
UNIT 2 - SUITE 5
UNIT 2 - SUITE 2UNIT 2 - SUITE 1
UNIT 1 - SUITE 6UNIT 1 - SUITE 5UNIT 1 - SUITE 3
UNIT 1 - SUITE 4
UNIT 1 - SUITE 2UNIT 1 - SUITE 1UNIT 2 - SUITE 3UNIT 2 - SUITE 4LEGEND - FIRE RATINGS AND EGRESS2 HOUR RATED FIRE BARRIER.1 HOUR RATED FIRE BARRIER.TRAVEL DISTANCE EXIT ACCESS TO EXIT DISCHARGE.DEAD END CORRIDOR LENGTH.COMMON PATH OF TRAVEL FROM DWELLING UNIT TO EXIT ACCESS.WWBCCBCCDW86'-0" TRAVEL DISTANCE27'-0" TRAVEL DISTANCE54'-0" TRAVEL DISTANCE31'-0" TRAVEL DISTANCE 44'-0" DEAD END CORRIDOR LENGTH27'-0" DEAD END CORRIDOR LENGTH
51'-0" COMMON PATH OF TRAVEL DISTANCE1. NYSBC 302:OCCUPANCY GROUP: R22. NYSBC TABLE 601: CONSTRUCTION CLASSIFICATION: TYPE 2B3. NYSEBC CHAPTER 5: ALTERATION LEVEL 24. FULLY SPRINKLERED5. NYSBC TABLE 504.3: ALLOWABLE BUILDING HEIGHT : 75 FEET6. NYSBC TABLE 504.4: NUMBER OF STORIES ABOVE GRADE: 5A. ACTUAL NUMBER OF STORIES: 37. NYSBC TABLE 506.2: ALLOWABLE AREA: 48,000 SQUARE FEET1. ACTUAL OVERALL BUILDING AREA: 12,220 SQUARE FEET2. ADD 36,000 SQUARE FEET OF ALLOWABLE BUILDING AREA FOR (4) SIDES FRONTAGE: 84,000 SQUARE FEET8. NYSEBC 805.3.1.6: MAXIMUM TRAVEL DISTANCE WITHIN DWELLING UNIT: 75 FEET9. NYSEBC 805.7.2: FIRE ESCAPES PERMITTED AS SECOND EXIT.10. NYSEBC 803.6: COMMUNICATING STAIRS REQUIRE NO ENCLOSURE FOR FULLY SPRINKLERED BUILDINGS11. NYSEBC 803.6: FIRE RESISTANCE RATINGS FOR CORRIDORS SHALL MEET THE REQUIREMENTS OF NYSBC FOR SPRINKLERED BUILDINGS.12. NYSBC 708.4: FIRE PARTITION CONTINUITY: EXTEND FIRE PARTITION TO UNDERSIDE OF DECK OR TO THE UNDERSIDE OF FIRE RATED FLOOR / CEILING ASSEMBLY.13. NYSBC 1020.4, EXCEPTION 2:CORRIDOR DEAD END LENGTH MAX. 50 L.FBUILDING CODE COMPLIANCE (EXISTING BUILDING CODE)TYPICAL FOR EACH SUITE.
UPDN645464046404A645364526400CD64516400TD6400TC64646463646264616400CC6424642364226400CA6400CB6400TB6400TA64146413641264116421640264056400J64066400CK6400CH640164036400EA6400644164316400CG6400CF6442644364446434643364326400TF6400TE630263416300CE633163016300J6400EB6400CJ63066332633363346344634363426300CG6300CF6300TE6300TF632163116300CA6300CB6322632363246314631363126300TA6300TB635163616300CD6300CC6352635363546364636363626300TD6300TCDNUPDNUPDNUPDNUPDNUPDNDNDNDNDNDNUPDNDNDNDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETKITCHENKITCHENJANITORCLOSETJANITORCLOSETLOUNGELOUNGELOUNGETOILETTOILET6400SFFIREESCAPE 36400SCSTAIR 36400SEFIREESCAPE 36400SBSTAIR 36400SASTAIR A6300SASTAIR B6400SDFIREESCAPE 263POSSTAIR B6300SDFIREESCAPE 16300SCSTAIR 46300SFFIREESCAPE 46300SEFIREESCAPE 46300SBSTAIR 464POSSTAIR A6400CECORRIDORDATE:ISSUESHEET TITLEPROJECTPHASE 5LOWRISE 6 INTERIORMODIFICATIONS1ISSUED FOR BID2019-03-12SCALE:APPROVED BY:PROJECT MGR:IBI PROJECT NO:SHEET NUMBER237 JESSUP ROAD, ITHACA, NEW YORK 14850PRIME CONSULTANTCLIENTCOPYRIGHTISSUESCORNELLUNIVERSITYThis drawing has been prepared solely for the intended use, thus anyreproduction or distribution for any purpose other than authorized by IBI Group isforbidden. Written dimensions shall have precedence over scaled dimensions.Contractors shall verify and be responsible for all dimensions and conditions onthe job, and IBI Group shall be informed of any variations from the dimensions andconditions shown on the drawing. Shop drawings shall be submitted to IBI Groupfor general conformance before proceeding with fabrication.is a member of the IBI Group of companiesIBI GROUP ARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTSKEYPLANCHECKED BY:DRAWN BY:SCALE CHECK CONSULTANTSSEAL10mm1 in 59-61 Court Street,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comCLIENT PROJECT NO:ITHACA, NEW YORK 14850LOWRISE 6 AND 9IMPROVEMENTS ANDCODE REMEDIATION114475 11412AS NOTED2019-11-20PLANNORTHLEVEL 3 AND 4CODE COMPLIANCE PLANLR6-A001 A3/32" = 1' - 0"THIRD AND FOURTH LEVEL PLAN1PLANNORTHUNIT 4 - SUITE 6UNIT 4 - SUITE 5UNIT 4 - SUITE 2UNIT 4 - SUITE 1UNIT 4 - SUITE 4
UNIT 4 - SUITE 3
UNIT 3 - SUITE 1
UNIT 3 - SUITE 2
UNIT 3 - SUITE 5
UNIT 3 - SUITE 6UNIT 3 - SUITE 3UNIT 3 - SUITE 4WWBCCBCCDW28'-0" DEAD END CORRIDOR LENGTH 66'-0" TRAVEL DISTANCE28'-0" TRAVEL DISTANCE
54'-0" TRAVEL DISTANCE46'-0" DEAD END CORRIDOR LENGTH30'-0" TRAVEL DISTANCE
51'-0" COMMON PATH OF TRAVEL DISTANCEBUILDING CODE COMPLIANCE (EXISTING BUILDING CODE)TYPICAL FOR EACH SUITE.1. NYSBC 302:OCCUPANCY GROUP: R22. NYSBC TABLE 601: CONSTRUCTION CLASSIFICATION: TYPE 2B3. NYSEBC CHAPTER 5: ALTERATION LEVEL 24. FULLY SPRINKLERED5. NYSBC TABLE 504.3: ALLOWABLE BUILDING HEIGHT : 75 FEET6. NYSBC TABLE 504.4: NUMBER OF STORIES ABOVE GRADE: 5A. ACTUAL NUMBER OF STORIES: 37. NYSBC TABLE 506.2: ALLOWABLE AREA: 48,000 SQUARE FEET1. ACTUAL OVERALL BUILDING AREA: 12,220 SQUARE FEET2. ADD 36,000 SQUARE FEET OF ALLOWABLE BUILDING AREA FOR (4) SIDES FRONTAGE: 84,000 SQUARE FEET8. NYSEBC 805.3.1.6: MAXIMUM TRAVEL DISTANCE WITHIN DWELLING UNIT: 75 FEET9. NYSEBC 805.7.2: FIRE ESCAPES PERMITTED AS SECOND EXIT.10. NYSEBC 803.6: COMMUNICATING STAIRS REQUIRE NO ENCLOSURE FOR FULLY SPRINKLERED BUILDINGS11. NYSEBC 803.6: FIRE RESISTANCE RATINGS FOR CORRIDORS SHALL MEET THE REQUIREMENTS OF NYSBC FOR SPRINKLERED BUILDINGS.12. NYSBC 708.4: FIRE PARTITION CONTINUITY: EXTEND FIRE PARTITION TO UNDERSIDE OF DECK OR TO THE UNDERSIDE OF FIRE RATED FLOOR / CEILING ASSEMBLY.13. NYSBC 1020.4, EXCEPTION 2:CORRIDOR DEAD END LENGTH MAX. 50 L.FLEGEND - FIRE RATINGS AND EGRESS2 HOUR RATED FIRE BARRIER.1 HOUR RATED FIRE BARRIER.TRAVEL DISTANCE EXIT ACCESS TO EXIT DISCHARGE.DEAD END CORRIDOR LENGTH.COMMON PATH OF TRAVEL FROM DWELLING UNIT TO EXIT ACCESS.
DOOR SCHEDULEMARKDOORFRAME DETAILSFIRERATING(MINUTES)GLAZINGTYPEHARDWAREGROUP NO.KEYED NOTESSIZETYPE MAT FIN TYPE MAT FIN HEAD JAMBDOOR WIDTHHEIGHTTHICKNESSPANELS WIDTH6B00TA (1) 2'-8" 6'-8" 1 3/4" F WD FF F1 HM IP-10 H2/A003 J2/A003-6B00TB (1) 2'-8"1 3/4" F WD FFIP-10-6B03(1) 3' - 0"1 3/4"-6B04(1) 3' - 0"1 3/4"-(1) 3' - 4"1 3/4" F WD FFIP-1045-HW-26100J (1) 3' - 0"1 3/4" F WD FFIP-106100CC (1) 3' - 8"1 3/4" N WD FFIP-106102 (1) 3' - 0"1 3/4"(1) 3' - 0"1 3/4"6103 (1) 2'-8"1 3/4"6200EB (1) 2'-8"1 3/4"6200JA (1) 3' - 0"1 3/4"6200JB (1) 2'-8"1 3/4" F WD FFIP-10-6200SA (1) 3' - 4"1 3/4" N HM IP-10IP-10S-26200CH (1) 3' - 0"1 3/4" N WD FFIP-10S-16203 (1) 2'-8"1 3/4"6206 (1) 3' - 0"1 3/4"6207 (1) 3' - 0"1 3/4" F-6208 (1) 3' - 0"1 3/4" F-6302A (1) 3' - 0"1 3/4"6302B (1) 3' - 0"1 3/4"6306 (1) 3' - 0"1 3/4"6400CJ (1) 3' - 0"1 3/4"6401(1) 3' - 4"1 3/4"6B00U6402B(1) 3' - 0"1 3/4"6403(1) 3' - 0"1 3/4" N WD FFIP-106404A(1) 3' - 0"1 3/4"6404B(1) 3' - 0"1 3/4"6404C(1) 3' - 0"1 3/4"(1) 3' - 0"1 3/4"(1) 3' - 0"1 3/4"6402A6400J6400CH6400CF6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"6'-8"(1)(1) 3' - 0"1 3/4"6'-8"3' - 0"1 3/4"HMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMHMF1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1HW-2HW-2HW-1HW-1HW-2HW-7HW-7HW-7HW-1HW-8HW-2HW-4HW-7HW-7HW-1HW-9HW-2HW-2HW-1HW-1HW-9HW-7HW-7HW-7HW-2HW-1HW-1HW-1HW-1HW-4HW-5HW-3H2/A003 J2/A003H2/A003 J2/A003H2/A003 J2A/A002H1/A003 J1/A0034545F WD FFF WD FFIP-10IP-10454590WD FFIP-1045WD FFIP-10456045F-WD FFIP-1045F-WD FFIP-1045F HM IP-10IP-1090-F WD FFIP-10-4590S-345-NNWD FFIP-10S-145WD FFIP-10S-145F WD FFIP-1045-45-N WD FFF WD FFNRNR---IP-10IP-10IP-10IP-10IP-10F WD FFF WD FFF WD FFS-145S-14545IP-10IP-10IP-10IP-10IP-10IP-10IP-10IP-10-F WD FF45-F WD FF90N WD FFN WD FFS-145S-145-F WD FF45-F WD FF45N WD FF90N WD FF90S-3S-3H3/A003 J3/A003H5/A003 J5/J5A/A003H4/A003 J4/A003H5/A003 J5/A003H3/A003 J3/J4/A003H5/A003 J5A/A003H3/A003 J6/A003H3/A003 J6A/A003H8/A003 J8/A003H4/A003 J5/J7/A003H3/A003 J3/A003H4/A003 J7/A003H4/A003 J3/A003H4/A003 J3/A003H3/A003 J3/A003H3/A003 J3/A003H4/A003 J7/A003H9/A002 J9/A002H3/A003 J6/A003H5/A003 J5/A003H4/A003 J4/A003H3/A003 J6A/A003H3/A003 J3/A003H3/A003 J3/A003H3/A003 J6A/A003- J3/J6A/A003H4/A003 J7/A003H4/A003 J7/A003H4/A003 J4/A0036400CG(1) 3' - 0"1 3/4"6'-8"HMF1HW-7N WD FFIP-10S-1456400CENOTE 1PATCH TERRAZZO FLOOR WHERE PIVOT(2) 3' - 0"1 3/4"6'-8"HMF1HW-6F WD FFIP-10-NRH4/A003 J4/A003H4/A003 J4/A0036404B.1(1) 3' - 0"1 3/4"6'-8"HMF1HW-7N WD FFIP-10S-1456300CENOTE 3NOTE 3NOTE 11'-0"
71
2"2"534"12"12"712"12"1'-4"2"6"6"2"2"2"2"2'-8"3'-6"6"3"FIRE TEST DESIGN NO.:STC RATING:TAGDESIGN INFORMATIONS-31U419403 5/8" STEEL STUD PARTITION1-HR FIRE RATEDEXISTING ROOF/FLOOR DECKEXISTING/NEW FLOOR DECKCEILING +8'-0" APPROX.58" TYPE X GYPSUM WALLBOARDBOTH SIDES TO DECK, PAINTFIRE RATED BACKER RODAND JOINT SEALANTBOTH SIDESFIRE RATED BACKER RODAND JOINT SEALANTBOTH SIDES478"EXISTING FIRE RATED FLOOR/CEILING ASSEMBLYWOOD BASE TOMATCH EXISTING3" SOUND ATTENUATION FIRERATED BLANKETSMETAL CORNERBEAD AT EXPOSED, PAINTEDWALLBOARDINTERIOR FABRIC OR RIGID JOINTREINFORCEMENTAT EXPOSED, PAINTED WALLBOARDMETAL STUDS SUPPORTFULL EDGE OF WALLBOARDWALLBOARDPARTITION CORNERCJHIGHER RATED WALLFIRE RATED STUD WALL.SEE APPLICABLEPARTITION TYPES ANDTHEIR FIRE RATINGSTHIS SHEETPRIORITY SYSTEM FOR FIREPROTECTED PARTITIONSUNRATED OR LOWERFIRE RATED WALLBULLNOSE WALL TILEAT EXTERIOR CORNERSGLAZED WALL TILE (GWT)SEE ROOM FINISH SCHEDULEFOR APPLICATIONTYPICAL CONTROL JOINTSAW CUT AND REMOVE ACMWALLBOARD BACK TO NEARESTSTUD(2) LAYERS 58" TYPE X GWBEXISTING STEEL STUD3 8" 33 MIL. STEEL STUDSMETAL U-BEAD BY ASBESTOSCERTIFIED HANDLERAND PAINTER (BOTH SIDES)EXISTING ASBESTOS CONTAININGJOINT COMPOUND TO REMAINUNDISTURBEDBACKER ROD AND URETHANESEALANT, BOTH SIDES58" TYPE X GWB, BOTH SIDESDATE:ISSUESHEET TITLEPROJECTPHASE 5LOWRISE 6 INTERIORMODIFICATIONS1ISSUED FOR BID2019-03-12SCALE:APPROVED BY:PROJECT MGR:IBI PROJECT NO:SHEET NUMBER237 JESSUP ROAD, ITHACA, NEW YORK 14850PRIME CONSULTANTCLIENTCOPYRIGHTISSUESCORNELLUNIVERSITYThis drawing has been prepared solely for the intended use, thus anyreproduction or distribution for any purpose other than authorized by IBI Group isforbidden. Written dimensions shall have precedence over scaled dimensions.Contractors shall verify and be responsible for all dimensions and conditions onthe job, and IBI Group shall be informed of any variations from the dimensions andconditions shown on the drawing. Shop drawings shall be submitted to IBI Groupfor general conformance before proceeding with fabrication.is a member of the IBI Group of companiesIBI GROUP ARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTSKEYPLANCHECKED BY:DRAWN BY:SCALE CHECK CONSULTANTSSEAL10mm1 in 59-61 Court Street,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comCLIENT PROJECT NO:ITHACA, NEW YORK 14850LOWRISE 6 AND 9IMPROVEMENTS ANDCODE REMEDIATION114475 11412AS NOTED2019-11-20PLANNORTHLOW RISE 6DOOR SCHEDULE, DETAILSAND WALL PARTITIONSLR6-A002 AWWBCCBCCDW1 1/2" = 1' - 0"HEAD DETAILS11 1/2" = 1' - 0"JAMB DETAILS2EXISTING 5" MASONRY AND GYPSUM WALLBOARDHEADER ABOVE.EXISTING 8" MASONRY AND GYPSUM WALL.1/4" = 1' - 0"FRAME TYPES31/4" = 1' - 0"DOOR TYPES4DOOR KEYED NOTES1 ALL REMOVAL OF DOOR AND FRAME NEED TO BE DONE UNDER SUPERVISION OF SCHINDLER ELEVATOR MAINTENANCE STAFF.COMPONENTS MOUNTED ON FRAME AND WIRING THROUGH DOOR FRAME ARE TO BE SALVAGED AND REINSTALLED AS DIRECTED. COMPONENTS ASSOCIATED WITH EXISTING DUMBWAITER CANNOT BE REPLACED.1 1/2" = 1' - 0"WALL PARTITION TYPES53" = 1' - 0"TYPICAL PARTITION DETAILS6FIRE RATED CAULK, BOTH SIDES.HOLLOW METAL DOOR FRAME; PAINTED.HOLLOW METAL DOOR FRAME; PAINTED.FIRE RATED CAULK, BOTH SIDES.SAWCUT AND ABATE WALLBOARDAROUND DOOR OPENING ANDREPLACE WITH (1) LAYER58" TYPE X GWB LAMINATED TOEXISTING MASONRY.EXISTING MASONRYAND GYPSUM WALL.CONTROL JOINT TRIM, SEE DETAIL6/A003METAL U-BEAD CONTROLJOINT + BOTH SIDES;SIMILAR TO DETAIL 6/A003HOLLOW METAL DOORFRAME; PAINTED.FIRE RATED CAULK,BOTH SIDES.EXISTING MASONRYWITH ACM GYPSUMWALLBOARD BOTH SIDES2. PATCH TERRAZZO FLOORING TO MATCH AT EXISTING PVIOT HINGED REMOVAL.3. PATCH AND GROUT EXISTING SLAB AND RESILIENT TILE FLOORING AT EXISTING PIVOT HINGE REMOVAL.SAWCUT AND ABATE WALLBOARDAROUND DOOR OPENING ANDREPLACE WITH (1) LAYER58" TYPE X GWB LAMINATED TOEXISTING MASONRY.CONTROL JOINT TRIM, SEE DETAIL6/A003SURFACE MOUNTED MASONRYDOOR ANCHORS W/ (1) 38" X 2"EXPANSION BOLT AND SHIELD(3) PER JAMB, MIN.
712"2"2"71
2"2"12"
12"2"6"
6"478"478"2"6"
47
8"1'-6"6"2"478"9"6"1'-4"2"2"6"
5"1'-0"5"6"1'-4"2"2"7 1
4"512"4'-6" +/-2"8"6 18"7 14"1'-4"2"
61
2"
51
2"2"612"512"1'-4"1'-0"47
8"
6"2"1'-4"2"6"478"DATE:ISSUESHEET TITLEPROJECTPHASE 5LOWRISE 6 INTERIORMODIFICATIONS1ISSUED FOR BID2019-03-12SCALE:APPROVED BY:PROJECT MGR:IBI PROJECT NO:SHEET NUMBER237 JESSUP ROAD, ITHACA, NEW YORK 14850PRIME CONSULTANTCLIENTCOPYRIGHTISSUESCORNELLUNIVERSITYThis drawing has been prepared solely for the intended use, thus anyreproduction or distribution for any purpose other than authorized by IBI Group isforbidden. Written dimensions shall have precedence over scaled dimensions.Contractors shall verify and be responsible for all dimensions and conditions onthe job, and IBI Group shall be informed of any variations from the dimensions andconditions shown on the drawing. Shop drawings shall be submitted to IBI Groupfor general conformance before proceeding with fabrication.is a member of the IBI Group of companiesIBI GROUP ARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTSKEYPLANCHECKED BY:DRAWN BY:SCALE CHECK CONSULTANTSSEAL10mm1 in 59-61 Court Street,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comCLIENT PROJECT NO:ITHACA, NEW YORK 14850LOWRISE 6 AND 9IMPROVEMENTS ANDCODE REMEDIATION114475 11412AS NOTED2019-11-20PLANNORTHLOW RISE 6DOOR DETAILSLR6-A003 AWWBCCBCCDW1 1/2" = 1' - 0"HEAD DETAILS11 1/2" = 1' - 0"JAMB DETAILS2FIRE RATED WALL CAP. (DOORS 6302A / B, 6400CF,6401 AND 6403 DO NOTREQUIRE WALL CAP).EXISTING GYPSUM WALLBOARD TO REMAIN (BOTHSIDES).EXISTING GYPSUM WALLBOARD CEILING.SAWCUT AND ABATE WALLBOARD AROUND DOORTO STUD AND REPLACE WITH (1) LAYER 58" TYPE XGYPSUM WALLBOARD; BOTH SIDES.ADD (1) 3 58" 33 MIL. STEEL STUD.SAWCUT AND ABATE WALLBOARD AROUND DOORTO STUD AND REPLACE WITH (1) LAYER 58" TYPE XGYPSUM WALLBOARD; BOTH SIDES.SEE TYPICAL CONTROLJOINT DETAIL #6,A002 FORMORE INFORMATION3 58" 33 MIL. BUILT UP STEEL STUD HEADER.EXISTING TWO-HOUR RATED STEEL STUD PARTITION.EXISTING GYPSUM CEILING BOARD (DOOR 6200EB ISOPEN SHAFT).(2) LAYERS 58" TYPE X GYPSUM WALL BOARD BOTHSIDES ON 3 58" 33 MIL. STEEL STUDS.SEE TYPICAL CONTROLJOINT DETAIL #6,A002 FORMORE INFORMATION(2) LAYERS 58" TYPE X GYPSUM WALL BOARD BOTHSIDES ON 3 58" 33 MIL. STEEL STUDS.FIRE CAULK PERIMETER, BOTH SIDES.ABATE STUD PARTITION TO CEILING AND RE-BUILD.3 58" 33 MIL. STEEL STUD BLOCKING AT 24" O.C.14" TOGGLE BOLT.EXISTING LIGHT GAUGE CEILINGJOISTS AND CEILING BOARD.(1) LAYER 58" TYPE X GYPSUM WALLBOARD BOTH SIDESON 3 58" 33 MIL. STEEL STUD AT 16" O.C.(1) LAYER 58" TYPE X GYPSUM WALLBOARD BOTH SIDESON 3 58" 33 MIL. STEEL STUD AT 16" O.C.FIRE CAULK PERIMETER, BOTH SIDES.3" SOUND ATTENUATION FIRE BLANKETS.(1) LAYER 58" TYPE X GYPSUM WALLBOARD BOTH SIDESON 3 58" 33 MIL. STEEL STUD AT 16" O.C.3" SOUND ATTENUATION FIRE BLANKETS.FIRE CAULK AROUND PERIMETER, BOTH SIDES.FIRE CAULK AROUND PERIMETER, BOTH SIDES.EXISTING FULL BED PLASTER AND 6" MASONRYBLOCK.SURFACE MOUNTED MASONRY ANCHORS.FIRE CAULK AROUND PERIMETER, BOTH SIDES.EXISTING FULL BED PLASTER AND 6" MASONRYBLOCK.EXISTING STEEL STUD WALL ANDWALLBOARD TO REMAIN..SEE TYPICAL CONTROLJOINT DETAIL #6,A002 FORMORE INFORMATIONADD 3 58" 33 MIL. STEEL STUDS FULLHEIGHT EXISTING TRACK TO TRACK(APPROX. 8'-4" HT.)EXISTING WALL BOARDTO REMAIN. ON MIRRORSIDE AS WELL.CONTROL JOINT TRIM, DO NOT ATTACHOR SPACKLE TO EXISTING WALLBOARDSIDE; CAULK ONLY.METAL CORNER TRIM, DO NOT ATTACHOR SPACKLE TO EXISTING WALLBOARDSIDE; CAULK ONLY.FIRE CAULK PERIMETER, BOTH SIDES.58" TYPE X GYPSUM WALLBOARD SECUREDTO EXISTING FURRING STRIPS.SEE TYPICAL CONTROLJOINT DETAIL #6,A002 FORMORE INFORMATIONSAWCUT AND ABATE GYPSUM WALLBOARDAROUND EXISTING DOOR OPENING.EXISTING 34" FURRING STRIPS TO REMAIN.EXISTING 4" MASONRY PARTITION.HOLLOW METAL DOOR FRAME, FIELD PAINTED.SURFACE MOUNTED MASONRY ANCHOR.EXISTING GYPSUM CEILING BOARD.EXISTING 34" FURRING STRIPS TO REMAIN.FIRE RATED CAULK.ABATE (2) LAYERS WALLBOARD ANDREPLACE WITH (2) LAYERS 58" TYPE XGYPSUM WALLBOARD.FIRE CAULK, BOTH SIDES.ABATE (2) LAYERS WALLBOARD ANDREPLACE WITH (2) LAYERS 58" TYPE XGYPSUM WALLBOARD. SEE HM DRAWINGSFOR MORE INFORMATION ON ABATEMENT.FIRE CAULK, BOTH SIDES.HOLLOW METAL DOOR FRAME; PAINTED.HOLLOW METAL DOOR FRAME; PAINTED.HOLLOW METAL DOOR FRAME; PAINTED.HOLLOW METAL DOOR FRAME; PAINTED.HOLLOW METAL DOOR FRAME; PAINTED.HOLLOW METAL DOORFRAME; PAINTED.HOLLOW METAL DOOR FRAME; PAINTED.HOLLOW METAL DOOR FRAME; PAINTED.HOLLOW METAL DOOR FRAME; PAINTED.HOLLOW METAL DOOR FRAME; PAINTED.HOLLOW METAL DOOR FRAME; PAINTED.HOLLOW METAL DOOR FRAME; PAINTED.HOLLOW METAL DOOR FRAME; PAINTED.HOLLOW METAL DOOR FRAME; PAINTED.FIRE CAULK BOTH SIDESFIRE CAULK PERIMETER, BOTH SIDES.FIRE RATED CAULK PERIMETER, BOTH SIDES.EXISTING 4" MASONRY PARTITION.FIRE CAULK.EXISTING STEEL STUDS TO REMAIN.ADD (1) 3 58" 33 MIL. STEEL STUD.FIRE CAULK PERIMETER, BOTH SIDES.ADD (2) LAYERS 58" TYPE X GYPSUM WALLBOARD AT EXISTINGTWO-HOUR FIRE BARRIER.FIRE CAULK, BOTH SIDES.EXISTING STEEL STUDS TO REMAIN.EXISTING MASONRY WALL.FIRE RATED CAULKPERIMETER, BOTH SIDES.FIRE RATED CAULKPERIMETER, BOTH SIDES.HINGE SIDE.EXISTING FIRE RATED FLOOR/CEILING ASSEMBLY58" TYPE X GWB
HINGE APPROACH,PUSH SIDE4'-0" MIN. REQ'D W/
BOTH CLOSER AND
LATCH PROVIDED SHADED AREA DENOTESWHEELCHAIR MANEUVERING CLEARANCE12" * - REQUIRED WHEN BOTHCLOSER AND LATCH ARE PROVIDED.SHOWS DIRECTION OF APPROACH.HINGE APPROACH,PULL SIDELATCH APPROACH,PULL SIDE4'-6" MINIMUM WITH CLOSER.4'-0" MINIMUM WITH CLOSER.LATCH APPROACH,PUSH SIDEFRONTAPPROACH, PUSH SIDEFRONT APPROACH,PULL SIDEHINGE APPROACH,PULL SIDEMIN. OPENINGCLEARANCE9
0
°DOOR CLEARANCE - ICC/ANSI A117.1-20095'-0"3'-0"2'-0"4'-0"2'-0"3'-6"
3'-6"4'-6"32" MIN3'-6"4'-6"1'-6"5'-0"1'-0"4'-0"60-IN. DIAMETER SPACET-SHAPED SPACE FOR 180° TURNS3'-0"1'-0"1'-0"5'-0"
3'-0"2'-0"5'-0"5'-0"5'-0"
27" AFF.4" MAX.307.2 - PROTRUSION LIMITSOBJECTS WITH LEADING EDGES MORE THAN 27 INCHES (2'-3")AND NOT MORE THAN 80 INCHES (6'-8") ABOVE THE FLOORSHALL PROTRUDE 4 INCHES MAXIMUM HORIZONTALLY INTO THECIRCULATION PATH.18 12"35"40"1' - 6" MIN.12"48"3'-0"40"35"36'5"9" MIN.8" MIN.1' - 5" MIN.6" MAX. TOECLEARANCE2'-3"MIN.2'-10"MAX.3'-4"
2'-10"
3'-4"
TO REFLECTORLAVATORY AND ACCESSORIES - ADATOILET - ADALAVATORY CLEARANCES - ADA18"17"CL6'-8"MAX. SIDE REACHOVER OBSTRUCTIONHIGH/LOW SIDEREACH LIMITSCLOSETFIRE EXTINGUISHERSHELVES46"
34" MAX.24"30"30"0'-9"
48" MAX.
32" - 42" PREFERRED
0'-10"48" MAX
21" MAX.48" MAX.
48" MAX. ACCESS RANGE
21" MAX.1'-3"
MIN.
12" MIN.
4'-0"
32" - 42" PREFERREDOUTLET / SWITCHES / CONTROLSACCESSIBLE REACH RANGESDATE:ISSUESHEET TITLEPROJECTPHASE 5LOWRISE 6 INTERIORMODIFICATIONS1ISSUED FOR BID2019-03-12SCALE:APPROVED BY:PROJECT MGR:IBI PROJECT NO:SHEET NUMBER237 JESSUP ROAD, ITHACA, NEW YORK 14850PRIME CONSULTANTCLIENTCOPYRIGHTISSUESCORNELLUNIVERSITYThis drawing has been prepared solely for the intended use, thus anyreproduction or distribution for any purpose other than authorized by IBI Group isforbidden. Written dimensions shall have precedence over scaled dimensions.Contractors shall verify and be responsible for all dimensions and conditions onthe job, and IBI Group shall be informed of any variations from the dimensions andconditions shown on the drawing. Shop drawings shall be submitted to IBI Groupfor general conformance before proceeding with fabrication.is a member of the IBI Group of companiesIBI GROUP ARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTSKEYPLANCHECKED BY:DRAWN BY:SCALE CHECK CONSULTANTSSEAL10mm1 in 59-61 Court Street,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comCLIENT PROJECT NO:ITHACA, NEW YORK 14850LOWRISE 6 AND 9IMPROVEMENTS ANDCODE REMEDIATION114475 11412AS NOTED2019-11-20PLANNORTHLOW RISE 6ADA COMPLIANCE,ABBREVIATIONS ANDSYMBOLS KEYLR6-A004 ANONEACCESSIBLE FIXTURE AND ACCESSORIES HEIGHTS AND CLEARANCES1BEDROOM CLOSET - NORTHNONEADA CLERANCES2BEDROOM CLOSET - NORTHA&AND@ ATACT ACOUSTICAL CEILING TILEALT ALTERNATEALUM ALUMINUMAVG AVERAGEAFF ABOVE FINISH FLOORBBD BOARDBLDG BUILDINGBOD BOTTOM OF DECKBSMT BASEMENTB/W BETWEENCCBU CEMENTITOUS BACKER UNITCG CORNER GUARDSCJ CONTROL JOINTCLG CEILINGCL CENTER LINECLR CLEARCMU CONCRETE MASONRY UNITCOL COLUMNCONC CONCRETECONF CONFERENCECONT CONTINUOUSCORR CORRIDORCPT CARPETCRS COURSE(S)CT CERAMIC TILEDDEMO DEMOLITIONDF DRINKING FOUNTAINDIA DIAMETERDIM DIMENSIONDN DOWNDO DOOR OPENINGDWG DRAWINGEEA EACHEJ EXPANSION JOINTELEC ELECTRICELEV ELEVATION/ ELEVATOREPDM RUBBER ROOF MEMBRANEEQ EQUALEX'G EXISTINGEXT EXTERIORF/F FACE OFFD FLOOR DRAINFDN FOUNDATIONFEC FIRE EXTINGUISHER CABINETFFE FINISH FLOOR ELEVATIONFRPFIBER REINFORCED POLYESTERFT FOOT/FEETFTG FOOTINGGGA GAGEGALV GALVANIZEDGC GENERAL CONTRACTORGEN GENERALGL GLASSGWB GYPSUM WALL BOARDHHC HANDICAPPEDHTHEIGHTHM HOLLOW METALHR HOURHVAC HEATING, VENTILATING & ACJJAN JANITORLLAV LAVATORYLB/# POUNDLGMF LIGHT GAGE METAL FRAMINGMMEPMECHANICAL, ELECTRICAL, ANDPLUMBINGMFR MANUFACTURERMAT MATERIALMAX MAXIMUMMEZZ MEZZANINEMIN MINIMUMMO MASONRY OPENINGMTL METALNNA NOT APPLICABLENIC NOT IN CONTRACTNR NOT RATEDNTS NOT TO SCALEOOC ON CENTEROD OUTSIDE DIAMETEROPNG OPENINGOSB ORIENTER STRAND BOARDP+/- PLUS OR MINUSPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPT PRESSURE TREATEDQQTY QUANTITYRRRISERRDROOF DRAINREF REFRIGERATORREQ REQUIREDREV REVISIONRO ROUGH OPENINGRTU ROOF TOP UNITSSHTG SHEATHINGSIM SIMILARSF SQUARE FOOT/ FEETSS STAINLESS STEELSTL STEELSTD STANDARDTTTREADT&G TONGUE & GROOVETEL TELEPHONETEMP TEMPERATURETOS TOP OF STEELTVTELEVISIONTYP TYPICALVVCT VINYL COMPOSITION TILEVIF VERIFY IN FIELDWW/WITHW/O WITHOUTWD WOODDRAWING ABBREVIATIONS7'-11" AFF.PT-1LVT-1R/DX-XXXXXXXXXXXA101WALL TYPE SYMBOL101DOOR SYMBOLROOM NAME SYMBOL101ROOMNAMEXAXXXPLAN DETAIL SYMBOLINTERIOR ELEVATION SYMBOLSECTION SYMBOLSPOT ELEVATIONKEYED RENOVATION/DEMOLITION NOTEFLOOR TRANSITION AND TYPETOILET ACCESSORYDRAWING ABBREVIATIONSTA-XWWBCCBCCDWGRAB BARS SHOWN FOR WALLBLOCKING PURPOSES ONLY.GRAB BARS SHOWN FOR WALLBLOCKING PURPOSES ONLY.SQUARE FOOTAGE
62646263626262526200TD6200TC625362546200CE6200CD626162516214621362126200TF6200TE6224622362226200CG6200CF621162216234623362326200CB6200TB6200TA62446200CA6243624262416200CC6231620662036200JA62026200EA6200JB6200CH6200CM620762086200CJ620962106200L6200EB6200CK610261216100CE6100CD61036100J61066100CC61116112611361146100TC6100TD612261236124614161316100CB6100CA6100TA6100TB61326133613461446143614261616100CG6100CF61516152615361546164616361626100TE6100TFUPDNDNUPUPDNUPDNUPUPDNUPDNUPUPDNUPDNDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORKITCHENKITCHENJANITORCLOSETJANITORCLOSETCORRIDORVESTIBULEOFFICEMECHANICALMECHANICALVESTIBULELOUNGELOUNGEOFFICETOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETCORRIDORCORRIDOR6200SBSTAIR 26200SASTAIR A6100SASTAIR B6100SDFIREESCAPE 46200SDFIREESCAPE 36100SCSTAIR 16100SFFIREESCAPE 16100SEFIREESCAPE 16100SBSTAIR 16200SCSTAIR 26200SFFIREESCAPE 16200SEFIREESCAPE 26103620762086200JA62066100CC6200EB61000J6200SA620362000JB6200CH61026B016B01A6B036B00U6B00EB6B046B00C6B026B00TB6B00TA6B00EAUPUPTOILETTOILETCORRIDORMECHANICALMECHANICALSTORAGESTORAGESTORAGELAUNDRY6B00SBSTAIR B6B00SBSTAIR 36B00SASTAIR A6B00TA6B00TB6B036B00U6B04DATE:ISSUESHEET TITLEPROJECTPHASE 5LOWRISE 6 INTERIORMODIFICATIONS1ISSUED FOR BID2019-03-12SCALE:APPROVED BY:PROJECT MGR:IBI PROJECT NO:SHEET NUMBER237 JESSUP ROAD, ITHACA, NEW YORK 14850PRIME CONSULTANTCLIENTCOPYRIGHTISSUESCORNELLUNIVERSITYThis drawing has been prepared solely for the intended use, thus anyreproduction or distribution for any purpose other than authorized by IBI Group isforbidden. Written dimensions shall have precedence over scaled dimensions.Contractors shall verify and be responsible for all dimensions and conditions onthe job, and IBI Group shall be informed of any variations from the dimensions andconditions shown on the drawing. Shop drawings shall be submitted to IBI Groupfor general conformance before proceeding with fabrication.is a member of the IBI Group of companiesIBI GROUP ARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTSKEYPLANCHECKED BY:DRAWN BY:SCALE CHECK CONSULTANTSSEAL10mm1 in 59-61 Court Street,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comCLIENT PROJECT NO:ITHACA, NEW YORK 14850LOWRISE 6 AND 9IMPROVEMENTS ANDCODE REMEDIATION114475 11412AS NOTED2019-11-20PLANNORTHLOW RISE 6LEVEL 1 & 2OVERALL FLOOR PLANLR6-A100 A3/32" = 1' - 0"FIRST AND SECOND LEVEL PLAN13/32" = 1' - 0"BASEMENT LEVEL PLAN2A3003A3004A3006A3005PLANNORTHPLANNORTHLEGENDXXEGRESS CORRIDORS:STUD PARTITION TOP OF WALL FIRESTOPPING. SEE DETAIL 1 ON A104.SELECT DOOR REPLACEMENT AND NEW DOORS IN NEW PARTITIONS:REMOVE EXISTING ACM DOORS AND HOLLOW METAL FRAMES; REPLACE WITHHOLLOW METAL FRAME AND WOOD DOORS; ALL NEW DOOR HARDWARE. FINISHDOORS AND FRAMES; PATCH WALLS AND FLOORING. SEE HAZARDOUSMATERIALS DRAWING SERIES FOR MORE INFORMATION.WWBCCBCCDWEGRESS CORRIDORS:MASONRY PARTITION TOP OF WALL FIRESTOPPING. SEE DETAIL 2 ON A104 ANDAS SPECIFIED IN SECTION 078400.A1036A1038199 S.F201 S.F103 S.F106 S.F206 S.F205 S.F106 S.F105 S.F201 S.F199 S.F105 S.F106 S.F206 S.F206 S.F106 S.F103 S.F166 S.F212 S.F106 S.F105 S.F199 S.F198 S.F105 S.F106 S.F212 S.F202 S.F209 S.F102 S.F107 S.F200 S.F193 S.F106 S.F104 S.F208 S.F163 S.F209 S.F211 S.F105 S.F105 S.F199 S.F200 S.F106 S.F105 S.F209 S.F102 S.F107 S.F200 S.F193 S.F106 S.F104 S.F208 S.F
UPDN645464046404A645364526400CD64516400TD6400TC64646463646264616400CC6424642364226400CA6400CB6400TB6400TA64146413641264116421640264056400J64066400CK6400CH640164036400EA6400644164316400CG6400CF6442644364446434643364326400TF6400TE630263416300CE633163016300J6400EB6400CJ63066332633363346344634363426300CG6300CF6300TE6300TF632163116300CA6300CB6322632363246314631363126300TA6300TB635163616300CD6300CC6352635363546364636363626300TD6300TCDNUPDNUPDNUPDNUPDNUPDNDNDNDNDNDNUPDNDNDNDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETKITCHENKITCHENJANITORCLOSETJANITORCLOSETLOUNGELOUNGELOUNGETOILETTOILET6400SFFIREESCAPE 36400SCSTAIR 36400SEFIREESCAPE 36400SBSTAIR 36400SASTAIR A6300SASTAIR B6400SDFIREESCAPE 263POSSTAIR B6300SDFIREESCAPE 16300SCSTAIR 46300SFFIREESCAPE 46300SEFIREESCAPE 46300SBSTAIR 464POSSTAIR A6400CECORRIDOR6404S6404BDWELLING6404D6404C6402A6400CE640364016400CH6400CF6400CG6400CJ63066402B6400J6302A6302B6300CEDATE:ISSUESHEET TITLEPROJECTPHASE 5LOWRISE 6 INTERIORMODIFICATIONS1ISSUED FOR BID2019-03-12SCALE:APPROVED BY:PROJECT MGR:IBI PROJECT NO:SHEET NUMBER237 JESSUP ROAD, ITHACA, NEW YORK 14850PRIME CONSULTANTCLIENTCOPYRIGHTISSUESCORNELLUNIVERSITYThis drawing has been prepared solely for the intended use, thus anyreproduction or distribution for any purpose other than authorized by IBI Group isforbidden. Written dimensions shall have precedence over scaled dimensions.Contractors shall verify and be responsible for all dimensions and conditions onthe job, and IBI Group shall be informed of any variations from the dimensions andconditions shown on the drawing. Shop drawings shall be submitted to IBI Groupfor general conformance before proceeding with fabrication.is a member of the IBI Group of companiesIBI GROUP ARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTSKEYPLANCHECKED BY:DRAWN BY:SCALE CHECK CONSULTANTSSEAL10mm1 in 59-61 Court Street,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comCLIENT PROJECT NO:ITHACA, NEW YORK 14850LOWRISE 6 AND 9IMPROVEMENTS ANDCODE REMEDIATION114475 11412AS NOTED2019-11-20PLANNORTHLOW RISE 6LEVEL 3 & 4OVERALL FLOOR PLANLR6-A101 A3/32" = 1' - 0"THIRD AND FOURTH LEVEL PLAN17A3008A300PLANNORTHWWBCCBCCDW1A1032A1034A1035A103204 S.F211 S.F107 S.F105 S.F206 S.F209 S.F105 S.F107 S.F166 S.F211 S.F104 S.F105 S.F202 S.F202 S.F105 S.F107 S.F209 S.F202 S.F105 S.F107 S.F209 S.F211 S.F202 S.F105 S.F104 S.F164 S.F210 S.F208 S.F102 S.F105 S.F199 S.F202 S.F105 S.F105 S.F210 S.F207 S.F105 S.F110 S.F196 S.F201 S.F106 S.F106 S.F210 S.F207 S.F105 S.F110 S.F196 S.F201 S.F106 S.F106 S.FLEGENDXXEGRESS CORRIDORS:STUD PARTITION TOP OF WALL FIRESTOPPING. SEE DETAIL 1 ON A104.SELECT DOOR REPLACEMENT AND NEW DOORS IN NEW PARTITIONS:REMOVE EXISTING ACM DOORS AND HOLLOW METAL FRAMES; REPLACE WITHHOLLOW METAL FRAME AND WOOD DOORS; ALL NEW DOOR HARDWARE. FINISHDOORS AND FRAMES; PATCH WALLS AND FLOORING. SEE HAZARDOUSMATERIALS DRAWING SERIES FOR MORE INFORMATION.EGRESS CORRIDORS:MASONRY PARTITION TOP OF WALL FIRESTOPPING. SEE DETAIL 2 ON A104 ANDAS SPECIFIED IN SECTION 078400.
6200CG6200CF62116221623362326200CB6200TB6200TA6200CA6243624262416200CC6231620662036200JA62026200EA6200JB6200CH6200CM620762086200CJ620962106200L6200EB6200CK610261216100CE6100CD61036100J61066100CC6111611261136100TC6100TD61226123614161316100CB6100CAUPDNUPDNUPUPDNUPDNUPDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORKITCHENKITCHENJANITORCLOSETJANITORCLOSETCORRIDORVESTIBULEOFFICEMECHANICALMECHANICALVESTIBULELOUNGELOUNGEOFFICETOILETTOILETTOILETTOILET6200SBSTAIR 26200SASTAIR A6100SASTAIR B6100SBSTAIR 13'-7"7'-10"17'-10"15'-1"3'-4"6'-2"4'-1"31'-1"3'-9"10'-7"11'-1"20'-11"3'-6"15'-8"3'-3"6103620762086200JA62066100CC6200EB61000J6200SA620362000JB6200CH6102642364226400CA6400CB6400TB6400TA6413641264116421640264056400J64066400CK6400CH640164036400EA6400644164316400CG6400CF644264326400TF6400TEUPDNUPDNDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORTOILETTOILETTOILETTOILETKITCHENJANITORCLOSETLOUNGELOUNGETOILETTOILET6400SBSTAIR 36400SASTAIR A6400CECORRIDOR6'-10"18'3'17'-3"11'-1"8'-8"7'-7"13'-8"3'-5"17'-8"7'-10"6402A6400CE640364016400CH6400CF6400CG6402B6400JUP64046404A6400630263416300CE633163016300J6400EB6400CJ630663326333634363426300CG6300CF6300TE6300TF632163116300CA6300CB6322631363126300TA6300TBUPDNUPDNDNDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORTOILETTOILETTOILETTOILETKITCHENJANITORCLOSETLOUNGELOUNGE6300SASTAIR B6300SBSTAIR 418'-1"7'-11"3'-4"15'-1"6'-8"4'-1"18'-2"7'-9"3'-5"5'-5"19'-2"6400CJ63066302A6302B6300CEDATE:ISSUESHEET TITLEPROJECTPHASE 5LOWRISE 6 INTERIORMODIFICATIONS1ISSUED FOR BID2019-03-12SCALE:APPROVED BY:PROJECT MGR:IBI PROJECT NO:SHEET NUMBER237 JESSUP ROAD, ITHACA, NEW YORK 14850PRIME CONSULTANTCLIENTCOPYRIGHTISSUESCORNELLUNIVERSITYThis drawing has been prepared solely for the intended use, thus anyreproduction or distribution for any purpose other than authorized by IBI Group isforbidden. Written dimensions shall have precedence over scaled dimensions.Contractors shall verify and be responsible for all dimensions and conditions onthe job, and IBI Group shall be informed of any variations from the dimensions andconditions shown on the drawing. Shop drawings shall be submitted to IBI Groupfor general conformance before proceeding with fabrication.is a member of the IBI Group of companiesIBI GROUP ARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTSKEYPLANCHECKED BY:DRAWN BY:SCALE CHECK CONSULTANTSSEAL10mm1 in 59-61 Court Street,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comCLIENT PROJECT NO:ITHACA, NEW YORK 14850LOWRISE 6 AND 9IMPROVEMENTS ANDCODE REMEDIATION114475 11412AS NOTED2019-11-20PLANNORTHLOW RISE 6ENLARGED FLOOR PLANSLR6-A102 A1/8" = 1' - 0"CORRIDOR WALL MODIFICATIONS11/8" = 1' - 0"CORRIDOR WALL MODIFICATIONS21/8" = 1' - 0"CORRIDOR WALL MODIFICATIONS3PLANNORTHPLANNORTHPLANNORTHWWBCCBCCDWLEGENDEGRESS CORRIDORS:STUD PARTITION TOP OF WALL FIRESTOPPING. SEE DETAIL 1 ON A104.EGRESS CORRIDORS:MASONRY PARTITION TOP OF WALL FIRESTOPPING. SEE DETAIL 2 ON A104.A1038A1037A1035A1034A1032A10312'X2' ACCESS PANELS:EXISTING FIRE RATED ACCESS PANEL.2'X2' ACCESS PANELS:PROVIDE NEW FIRE RATED ACCESS PANEL TO ACCOMMODATE NEW WORK.APAPAPAPAPAPAPAPAPAPAPAPAPA1036A1033
4'-8"1'-6"5'-8"UP20'-3"4'5'-2"5'-9"1'-6"5'-2"1'-6"4'4'-4"UP5'-2"5'-9"19'-3"4'4'-0" +/-8'-2"5'-2"1'-6"4'4'-4"5'-2"5'-8"3'-8"4'3'3'-8"4'3'DATE:ISSUESHEET TITLEPROJECTPHASE 5LOWRISE 6 INTERIORMODIFICATIONS1ISSUED FOR BID2019-03-12SCALE:APPROVED BY:PROJECT MGR:IBI PROJECT NO:SHEET NUMBER237 JESSUP ROAD, ITHACA, NEW YORK 14850PRIME CONSULTANTCLIENTCOPYRIGHTISSUESCORNELLUNIVERSITYThis drawing has been prepared solely for the intended use, thus anyreproduction or distribution for any purpose other than authorized by IBI Group isforbidden. Written dimensions shall have precedence over scaled dimensions.Contractors shall verify and be responsible for all dimensions and conditions onthe job, and IBI Group shall be informed of any variations from the dimensions andconditions shown on the drawing. Shop drawings shall be submitted to IBI Groupfor general conformance before proceeding with fabrication.is a member of the IBI Group of companiesIBI GROUP ARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTSKEYPLANCHECKED BY:DRAWN BY:SCALE CHECK CONSULTANTSSEAL10mm1 in 59-61 Court Street,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comCLIENT PROJECT NO:ITHACA, NEW YORK 14850LOWRISE 6 AND 9IMPROVEMENTS ANDCODE REMEDIATION114475 11412AS NOTED2019-11-20PLANNORTHLOW RISE 6ENLARGED FLOOR PLANS ANDDETAILSLR6-A103 A1/4" = 1' - 0"COMMON ROOM 6302 DEMOLITION PLAN11/4" = 1' - 0"COMMON ROOM 6402 DEMOLITION PLAN41/4" = 1' - 0"CORRIDOR RENO PLAN862066200CH6200JAJANITORCLOSET6206DWELLING6200CHCORRIDORSTAIR AS-311/4" = 1' - 0"COMMON ROOM 6302 RENOVATION PLAN21/4" = 1' - 0"COMMON ROOM 6402 RENOVATION PLAN5LEVEL 1LEVEL 2LEVEL 3LEVEL 4DEMOLITION NOTESD1 ABATE EXISTING DOOR AND HOLLOW METAL FRAME AND PORTION OF WALLBOARD AS DETAILED ON HM-100 AND HM-101.D2 ABATE EXISTING PORTION OF WALL TO DECK. REMOVE EXISTING ELECTRICAL DEVICES (SWITCHES, RECEPTACLES AND THERMOSTATS) REINSTALL IN NEW PARTITIONAS DIRECTED BY OWNER.SEE DRAWING HM-100 AND 101.D3 ABATE EXISTING GYPSUM CEILING BOARD CEILING AS NOTED ON HM-100 AND 101; EXISTING METAL STUD STRUCTURE TO REMAIN. TEMPORARILY SUPPORT SPRINKLERPIPING, LIGHTS AND ELECTRICAL DEVICES.SEE HM DRAWINGS FOR MORE INFORMATION ON ABATEMENT.D4 ABATE EXISTING WALLBOARD DOWN TO STEEL STUDS AS DIMENSIONED ON DOOR DETAILING DRAWINGS A002 AND A003.D5 ABATE EXISTING WOOD TRIM AROUND CLOSET; CLEAN ACM MATERIAL FROM TRIM; RE-INSTALL.D6 ABATE STUD AND GYPSUM WALLBOARD CLOSET HEADER TO CEILING ELEVATION; PATCH CEILING WITH (2) LAYERS 58" TYPE X GYPSUM CEILING PANEL; PAINT IP-2.2.D7 CUT AND REMOVE EXISTING FLOORING TO SLAB AND PREP FOR NEW WORK.RENOVATION NOTESR1 FIRE RATED WALL CAP TO EXISTING FIRE PARTITION; EXISTING CEILING CAN BE ACCESSED THROUGH DEMOLISHED CEILINGSOR 2' X 2' ACCESS DOORS.R2 ADD (1) LAYER 58" TYPE X GYPSUM WALLBOARD TO EXISTING STUD ABOVE CEILING AS DETAILED; ACCESS THROUGH DEMOLISHED CEILING.R3 ADD (2) LAYERS 58" TYPE X GYPSUM WALLBOARD CEILING BOARD; SECURE EXISTING SPRINKLER PIPING, LIGHTS AND ELECTRICAL DEVICES THROUGH CEILING BOARD AND INTO STEEL CEILING FRAMING.R4 PATCH AND PAINT GYPSUM CEILING BOARD AT PARTITION RELOCATION WITH (2) LAYERS 58" TYPE X GYPSUM CEILING BOARD.R5 FRAME A STEEL STUD AND 58" GYPSUM WALLBOARD HEADER TO EXISTING CEILING FRAMING AND CEILING BOARD; PAINT.R6 PATCH AND PAINT WALLBOARD AROUND NEWDOOR FRAMES, BOTH SIDES AS DETAILED ON DRAWING A003.R7 SALVAGE REMOVED CARPET FROM CORRIDOR 6100CA AND PATCH EXPOSED FLOOR SLAB TO MATCH EXISTING CARPETING.D16302AD16402B6402LOUNGER16302B6302LOUNGE6302COMMONROOM6300CECORRIDOR6301KITCHEN6300JJANITORCLOSET6300CECORRIDOR6301KITCHEN6300JJANITORCLOSET6402LOUNGE6405KITCHEN6400JJANITORCLOSET6400CECORRIDOR6405KITCHEN6400JJANITORCLOSETD1D16402AD3D31/4" = 1' - 0"CORRIDOR DEMO PLAN76200JAJANITORCLOSET6206DWELLING6200CHCORRIDORSTAIR AD1D26306DWELLINGPLANNORTHPLANNORTHPLANNORTHPLANNORTHPLANNORTHPLANNORTHLEVEL 2D3R3R13A1043A104LEVEL 26300CECORRIDORSTAIR BD3R2R36306DWELLING3A1043A1045A104R1R1R1R1D1D26406DWELLING6406DWELLING6400CECORRIDORR35A1046400J6400CER13A104R1WWBCCBCCDWS-31PARTITION LEGENDS-XXNEW STUD WALL, SEE DRAWING A002 FORDETAILING.D7R7D4D4D4D4D2D5D6D3R6R6R6R6R4R5ADUMBWAITERADUMBWAITERBDUMBWAITERBDUMBWAITERD4D4D4D4D4R6R6R6R66400EB6306R6PLANNORTH1/4" = 1' - 0"CORRIDOR DEMOLITION PLAN3LEVEL 16103KITCHEN6100JJANITORCLOSET6102COMMONROOM6100CCCORRIDOR6103KITCHEN6100JJANITORCLOSET6106DWELLINGUNIT6100CCCORRIDOR6100CCCORRIDOR6102.26101.16200EBD1D1R1R1R1S-31S-31D2D6D3D5D2D1BDUMBWAITERD4D4R6R6R4R7R5R6R66200EBDUMBWAITERAP6106DWELLINGUNIT3A1043A104PLANNORTH1/4" = 1' - 0"CORRIDOR RENOVATION PLAN6EXISTING EXIT SIGNEXISTING EXIT SIGNPROVIDE EXIT SIGNAGEMOUNTED TO CEILING;TIE INTO EXITING SIGNPROVIDE EXIT SIGNAGEMOUNTED TO CEILING;TIE INTO EXITING SIGNEXISTING EXIT SIGN
12"12"12"2 1/2"3"12"2 1/2"3'-11"6"4"DATE:ISSUESHEET TITLEPROJECTPHASE 5LOWRISE 6 INTERIORMODIFICATIONS1ISSUED FOR BID2019-03-12SCALE:APPROVED BY:PROJECT MGR:IBI PROJECT NO:SHEET NUMBER237 JESSUP ROAD, ITHACA, NEW YORK 14850PRIME CONSULTANTCLIENTCOPYRIGHTISSUESCORNELLUNIVERSITYThis drawing has been prepared solely for the intended use, thus anyreproduction or distribution for any purpose other than authorized by IBI Group isforbidden. Written dimensions shall have precedence over scaled dimensions.Contractors shall verify and be responsible for all dimensions and conditions onthe job, and IBI Group shall be informed of any variations from the dimensions andconditions shown on the drawing. Shop drawings shall be submitted to IBI Groupfor general conformance before proceeding with fabrication.is a member of the IBI Group of companiesIBI GROUP ARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTSKEYPLANCHECKED BY:DRAWN BY:SCALE CHECK CONSULTANTSSEAL10mm1 in 59-61 Court Street,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comCLIENT PROJECT NO:ITHACA, NEW YORK 14850LOWRISE 6 AND 9IMPROVEMENTS ANDCODE REMEDIATION114475 11412AS NOTED2019-11-20PLANNORTHLOW RISE 6CEILING DETAILSLR6-A104 AWWBCCBCCDW1 1/2" = 1' - 0"CEILING ACCESS DOOR41 1/2" = 1' - 0"WALL SECTION21 1/2" = 1' - 0"WALL SECTION1EXISTING GYPSUM CEILING BOARD TO REMAIN.VINYL CONTROL JOINTALL 4 SIDESEXISTING LIGHT GAUGE STEELCEILING JOISTSADD 3 58" 33 MIL. STEEL STUD FRAMED INTOEXISTING STEEL JOISTS. AROUND ALL 4 SIDES'OF ACCESS DOORABATE PORTION OF EXISTINGCEILING BOARDS AND ADD (2)LAYER 58" GWB TYPE X CEILINGBOARD AROUND ALL 4 SIDESOF NEW FIRE RATEDACCESS DOOR; PAINTFIRE RATED ACCESS DOOR ASSEMBLY, SEESPECIFICATIONS FOR MORE INFORMATION.EXISTING METAL STUD AND GYPSUM WALLBOARDPARTITION.EXISTING GYPSUM WALLBOARD AND METALSTUD CEILING ENCLOSURE.58" TYPE X GYPSUM WALLBOARD ON 2 12" 33 MIL. STEELSTUDS @ 24" O.C BOTH SIDES.TOP OF WALL FIRESTOPPING, PACK TIGHT TOSTEEL DECK.EXISTING ROOF DECK.EXISTING 12" STEEL BEAM.EXISTING OPEN WEB STEELBAR JOISTS, 48" O.CCONTINUOUS PATCH OF 58" TYPE XGYPSUM WALLBOARD REQUIRED ATTOP OF EXISTING PARTITION.EXISTING MASONRY BLOCK WALL.EXISTING GYPSUM WALLBOARD AND METAL STUDCEILING ENCLOSURE.58" TYPE X GYPSUM WALLBOARD ON 2 12" 33 MIL. STEELSTUDS @ 24" O.C BOTH SIDES.EXISTING 12" STEEL BEAM.EXISTING OPEN WEB STEELBAR JOISTS, 48" O.C1 1/2" = 1' - 0"WALL CAP SECTION3EXISTING STEEL STUD SOFFIT / CEILINGWITH GYPSUM WALLBOARD CEILINGBOARD ONE SIDE CORRIDOR.FIRE CAULK.(2) LAYERS 58" GYPSUM WALLBOARDTYPE X CONTINUOUS OVERTOP OF STEEL STUD PARTITION.EXISTING STEEL STUD SOFFIT /CEILING WITH GYPSUM WALLBOARDCEILING BOARD ONE SIDECORRIDOR TO REMAIN.EXISTING STEEL STUD PARTITIONWITH (2) LAYER 58" WALLBOARDBOTH SIDES.1 1/2" = 1' - 0"STAIR SECTION5EXISTING GYPSUM WALLBOARD CEILING ON LIGHT GAUGE METALHAT CHANNELS.ADD FIRE CAULKING AT TOP OF WALLBOARD.OPEN SPACE ABOVE CEILINGADD (1) LAYER 58" GYPSUM WALLBOARD TYPE XTO FACE OF EXISTING STUDS.ADD 3 58" 33 MIL. STUD BLOCKINGBETWEEN EXISTING STEEL STUDCEILING JOISTS.FIRE CAULK AT WALLBOARD AROUNDCEILING JOISTS.EXISTING STEEL STUD SOFFIT / CEILINGWITH GYPSUM WALLBOARD CEILINGBOARD ONE SIDE CORRIDOR TO REMAIN.REMOVE EXISTING GYPSUM WALLBOARD AS INDICATED ON DETAILS 3AND 4 ON A104.ADD (1) LAYER 58" TYPE X GYPSUM WALLBOARDCEILING BOARD AFTER EXISTING CEILINGBOARD IS ABATED AND ABOVE CEILINGWALLBOARD AND WALL CAP IS INSTALLED;PAINTFIRE CAULK.(2) LAYERS 58" GYPSUM WALLBOARDTYPE X CONTINUOUS OVERTOP OF STEEL STUD PARTITION.EXISTING STEEL STUD SOFFIT /CEILING WITH GYPSUM WALLBOARDCEILING BOARD ONE SIDECORRIDOR TO REMAIN.EXISTING STEEL STUD PARTITIONWITH (2) LAYER 58" WALLBOARDBOTH SIDES.13'-6" AFF.8'-0" AFF.EXISTING STEEL STUD PARTITIONWITH (1) LAYER 58" WALLBOARDBOTH SIDES.LOUNGEEXISTING STEEL STUD SOFFIT WITHGYPSUM WALLBOARD 58" ONE SIDE.EXISTING OPEN WEB STEELJOISTS.TOP OF WALL FIRESTOPPING, PACK TIGHT TOSTEEL DECK.EXISTING ROOF DECK.
LB FFE 884'-7 3/4"L1/L2 FFE 894'-5"L3/L4 FFE 904-2 1/2"ROOF TOS 918-7 1/2"PIT EL 881'-4"12"LB FFE 884'-7 3/4"L1/L2 FFE 894'-5"L3/L4 FFE 904-2 1/2"ROOF TOS 918-7 1/2"PIT EL 881'-4"12"12"12"12"12"12"4"9'-9"9'-9"14'-5"3'-8"4'6B00EA6B00SBSTAIR 33'-8"4'3'-8"4'3'3'-8"3'-8"4'5'-2"1'-6"4'4'-4"3'-8"4'6B00EB5"2"DATE:ISSUESHEET TITLEPROJECTPHASE 5LOWRISE 6 INTERIORMODIFICATIONS1ISSUED FOR BID2019-03-12SCALE:APPROVED BY:PROJECT MGR:IBI PROJECT NO:SHEET NUMBER237 JESSUP ROAD, ITHACA, NEW YORK 14850PRIME CONSULTANTCLIENTCOPYRIGHTISSUESCORNELLUNIVERSITYThis drawing has been prepared solely for the intended use, thus anyreproduction or distribution for any purpose other than authorized by IBI Group isforbidden. Written dimensions shall have precedence over scaled dimensions.Contractors shall verify and be responsible for all dimensions and conditions onthe job, and IBI Group shall be informed of any variations from the dimensions andconditions shown on the drawing. Shop drawings shall be submitted to IBI Groupfor general conformance before proceeding with fabrication.is a member of the IBI Group of companiesIBI GROUP ARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTSKEYPLANCHECKED BY:DRAWN BY:SCALE CHECK CONSULTANTSSEAL10mm1 in 59-61 Court Street,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comCLIENT PROJECT NO:ITHACA, NEW YORK 14850LOWRISE 6 AND 9IMPROVEMENTS ANDCODE REMEDIATION114475 11412AS NOTED2019-11-20PLANNORTHLOW RISE 6DUMBWAITER SHAFT PLANSAND SECTIONSLR6-A300 A1/2" = 1' - 0"DUMBWAITER SECTION11/2" = 1' - 0"DUMBWAITER SECTION2LEVEL 3 / 4LEVEL 3 / 4LEVEL 1 / 2LEVEL 1 / 2BASEMENTBASEMENT1/4" = 1' - 0"EAST DUMBWAITER 2 FLOOR PLAN41/4" = 1' - 0"EAST DUMBWAITER 2 FLOOR PLAN61/4" = 1' - 0"EAST DUMBWAITER 2 FLOOR PLAN81/4" = 1' - 0"WEST DUMBWAITER 1 FLOOR PLAN31/4" = 1' - 0"WEST DUMBWAITER 1 FLOOR PLAN51/4" = 1' - 0"WEST DUMBWAITER 1 FLOOR PLAN76B00CCORRIDOR6B00CCORRIDOR6B00TATOILETROOMA3002A30016B04STORAGEA3002A3001SIM.SIM.6200LLOBBY6100CCCORRIDORA3002A3001SIM.SIM.A3002A30016200CHCORRIDOR6200JBMAINTENANCE6200CJCORRIDORA3002A30016400CECORRIDOR6400CHCORRIDOR6403TOILETROOMA3002A3001SIM.SIM.6300CECORRIDOR6400CJCORRIDOR6404AKITCHENREMOVE EXISTING ACCESSDOOR AND RE-SETEXISTING CONCRETE PITFOUNDATIONEXISTING SLAB ON GRADEREMOVE EXISTING BATT INSULATIONAND REPLACE WITH TOP OF WALLFIRE STOPPING MATERIALEXISTING VERTICAL BI-PARTINGDUMBWAITER ACCESS DOORSEXISTING MASONRY SHAFT WALLREMOVE EXISTING BATT INSULATIONAND REPLACE WITH TOP OF WALLFIRE STOPPING MATERIALEXISTING CONCRETE SLAB ON STEELFRAMINGEXISTING VERTICAL BI-PARTINGDUMBWAITER ACCESS DOORSEXISTING METAL STUD SHAFT WALLREMOVE EXISTING BATT INSULATIONAND REPLACE WITH TOP OF WALLFIRE STOPPING MATERIALREMOVE EXISTING BATT INSULATIONAND REPLACE WITH TOP OF WALLFIRE STOPPING MATERIALEXISTING CONCRETE SLAB ON STEELFRAMINGEXISTING VERTICAL BI-PARTINGDUMBWAITER ACCESS DOORSEXISTING METAL STUD SHAFT WALLEXISTING HOIST AND FRAMING TOREMAIN IN PLACEADD TWO LAYERS OF 58" TYPE X GYPSUM WALLBOARD TO COVER EXISTING STEEL BEAM; FRAMEWITH MIN. 33 MIL. STUD AND FURRING MEMBERSWITH MAX. 24" O.C SPACINGEXISTING HOIST AND FRAMING TOREMAIN IN PLACETOP OF WALL FIRE STOPPINGMATERIAL WITH STEEL ROOF DECKCORRUGATIONSA3009REMOVE AND RE-INSTALLEXISTING ACCESS DOORREMOVE EXISTING BATT INSULATIONAND REPLACE WITH TOP OF WALLFIRE STOPPING MATERIAL1 1/2" = 1' - 0"SHAFT ACCESS PANEL9REMOVE AND RE-INSTALL EXISTINGACCESS DOOREXISTING METAL STUD AND GYPSUMBOARD SHAFT WALLPATCH HOLE WITH TWO LAYERS OF 58' TYPE XGYPSUM WALL BOARD ALL 4 SIDES; SEAL TO BEAMWITH FIRE RATED CAULKREMOVE AND RE-INSTALL EXISTINGACCESS DOORPATCH HOLE WITH TWO LAYERS OF 58' TYPE XGYPSUM WALL BOARD; SEAL TO BEAMWITH FIRE RATED CAULKA3009A3009REMOVE EXISTING BATT INSULATIONAND REPLACE WITH TOP OF WALLFIRE STOPPING MATERIALREMOVE EXISTING BATT INSULATIONAND REPLACE WITH FIRE STOPPINGMATERIAL AT ALL JUNCTION BOXESAND CABLING THAT PENETRATESREMOVE EXISTING BATT INSULATIONAND REPLACE WITH FIRE STOPPINGMATERIAL AT ALL JUNCTION BOXESAND CABLING THAT PENETRATESREMOVE EXISTING BATT INSULATIONAND REPLACE WITH FIRE STOPPINGMATERIAL AT ALL JUNCTION BOXESAND CABLING THAT PENETRATESREMOVE EXISTING BATT INSULATIONAND REPLACE WITH TOP OF WALLFIRE STOPPING MATERIALEXISTING METAL STUD SHAFT WALLEXISTING MASONRY SHAFT WALLSWING DOOR AND HOLLOW METALFRAME AT DUMBWAITERFIRE CAULK BELOW EXISTING STEEL BEAMEXISTING METAL STUD SHAFT WALLEXISTING METAL STUD SHAFT WALLMOVEMENT AND SECUREMENT OF HOISTCAB AND VERTICAL BI-PARTING DOORSSHALL BE COORDINATED WITH AND PERFORMEDBY HOIST SERVICE TECHNICIAN PROVIDED BYOWNERTOP OF WALL FIRESTOP MATERIALWITHIN EXISTING STEEL ROOF DECKCORRUGATIONSTHROUGH WALL PENETRATION FIRESTOPPINGAND CAULK AROUND BAR JOIST EACH SIDENOTE: OPPOSITE WALL REQUIRES THE SAME REMEDIATION EXCEPT ACCESS DOOR JAMB REPAIRSNOTE: OPPOSITE WALL REQUIRES THE SAME REMEDIATIONEXISTING CONCRETE PITFOUNDATIONPLANNORTHPLANNORTHPLANNORTHPLANNORTHPLANNORTHPLANNORTHWWBCCBCCDW
62646263626262526200TD6200TC625362546200CE6200CD626162516214621362126200TF6200TE6224622362226200CG6200CF621162216234623362326200CB6200TB6200TA62446200CA6243624262416200CC6231620662036200JA62026200EA6200JB6200CH6200CM620762086200CJ620962106200L6200EB6200CK610261216100CE6100CD61036100J61066100CC61116112611361146100TC6100TD612261236124614161316100CB6100CA6100TA6100TB61326133613461446143614261616100CG6100CF61516152615361546164616361626100TE6100TFUPDNDNUPUPDNUPDNUPUPDNUPDNUPUPDNUPDNDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORKITCHENKITCHENJANITORCLOSETJANITORCLOSETCORRIDORVESTIBULEOFFICEMECHANICALMECHANICALVESTIBULELOUNGELOUNGEOFFICETOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETCORRIDORCORRIDOR6200SBSTAIR 26200SASTAIR A6100SASTAIR B6100SDFIREESCAPE 46200SDFIREESCAPE 36100SCSTAIR 16100SFFIREESCAPE 16100SEFIREESCAPE 16100SBSTAIR 16200SCSTAIR 26200SFFIREESCAPE 16200SEFIREESCAPE 26B016B01A6B036B00U6B00EB6B046B00C6B026B00TB6B00TA6B00EAUPUPTOILETTOILETCORRIDORMECHANICALMECHANICALSTORAGESTORAGESTORAGELAUNDRY6B00SBSTAIR B6B00SBSTAIR 36B00SASTAIR ADATE:ISSUESHEET TITLEPROJECTPHASE 5LOWRISE 6 INTERIORMODIFICATIONS1ISSUED FOR BID2019-03-12SCALE:APPROVED BY:PROJECT MGR:IBI PROJECT NO:SHEET NUMBER237 JESSUP ROAD, ITHACA, NEW YORK 14850PRIME CONSULTANTCLIENTCOPYRIGHTISSUESCORNELLUNIVERSITYThis drawing has been prepared solely for the intended use, thus anyreproduction or distribution for any purpose other than authorized by IBI Group isforbidden. Written dimensions shall have precedence over scaled dimensions.Contractors shall verify and be responsible for all dimensions and conditions onthe job, and IBI Group shall be informed of any variations from the dimensions andconditions shown on the drawing. Shop drawings shall be submitted to IBI Groupfor general conformance before proceeding with fabrication.is a member of the IBI Group of companiesIBI GROUP ARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTSKEYPLANCHECKED BY:DRAWN BY:SCALE CHECK CONSULTANTSSEAL10mm1 in 59-61 Court Street,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comCLIENT PROJECT NO:ITHACA, NEW YORK 14850LOWRISE 6 AND 9IMPROVEMENTS ANDCODE REMEDIATION114475--AS NOTED2019-11-22PLANNORTHLOW RISE 6LEVEL 1 & 2HAZARDOUS MATERIALSPLANLR6-HM100BCDWWWBC1. INFORMATION PRESENTED ON THESE PLANS AND SPECIFICATIONS IS BASED ONASBESTOS SURVEYS CONDUCTED BY CORNELL UNIVERSITY CONSULTANTS.2. LOCATION OF PERSONAL/WASTE DECONTAMINATION ENCLOSURE SYSTEMS SHALLBE COORDINATED WITH THE OWNER'S REPRESENTATIVE.3. PLAN DIMENSIONS ARE APPROXIMATE AND MUST BE FIELD VERIFIED BY THECONTRACTOR. BIDS SHALL BE BASED SOLELY ON THE CONTRACTOR'S THOROUGHREVIEW OF THE DRAWINGS, SPECIFICATIONS AND SITE CONDITIONS. ANYDISCREPANCIES SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THEOWNER'S REPRESENTATIVE.4. COMPLETENESS OF ABATEMENT IS THE RESPONSIBILITY OF THE ABATEMENTCONTRACTOR. REMOVAL OF ALL ASBESTOS-CONTAINING MATERIALS (ACM) SHALL BETO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE.5. ASBESTOS WORK AREAS ARE IDENTIFIED ON THE CONTRACT DRAWINGS. ALL ACMWITHIN THE WORK AREAS ARE SCHEDULED FOR COMPLETE REMOVAL.6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PETITION THE NEW YORK STATEDEPARTMENT OF LABOR FOR ANY SITE SPECIFIC VARIANCES NECESSARY TOCOMPLETE THE WORK AS SPECIFIED. VARIANCE APPLICATION FEES SHALL BEINCLUDED IN THE BASE BID. ALL VARIANCES ARE SUBJECT TO REVIEW AND APPROVALBY THE OWNER'S REPRESENTATIVE.7. REMOVAL AND CONTAINERIZATION OF ACM SHALL BE COMPLETED IN STRICTACCORDANCE WITH THE STANDARD PROTOCOLS ESTABLISHED BY AHERA 40 CFR 763,NYSDOL ICR 56, OSHA 1926.1101 AND ANY SITE SPECIFIC VARIANCES GRANTED FORTHIS PROJECT INCLUDING, BUT NOT LIMITED TO, DECONTAMINATION AND WASTEREMOVAL PROCEDURES.8. WORK AREAS SHALL BE ISOLATED FROM THE SURROUNDING NON WORK AREAS INACCORDANCE WITH THE SPECIFICATIONS PRESENTED IN SPECIFICATION SECTION002800, AHERA 40 CFR 763, 12 NYCRR PART 56 AND OSHA 1926.1101.9. WORK AREAS SHALL BE PLACARDED WITH SIGNS THAT CONFORM TO OSHA AND 12NYCRR PART 56 STANDARDS. "CAUTION ASBESTOS" TAPE MAY BE USED AT OUTSIDEWORK AREAS. FRAMED AND SHEATHED BARRIERS MAY BE REQUIRED TO KEEPUNAUTHORIZED VISITORS OUT OF INTERIOR WORK AREAS.10. THOROUGHLY WET TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE ALLACM SCHEDULED FOR REMOVAL PRIOR TO STRIPPING AND/OR TOOLING TO REDUCEFIBER DISPERSAL INTO THE AIR.11. REMOVE SATURATED ACM IN SMALL SECTIONS FROM ALL AREAS. DO NOT ALLOWMATERIALS TO DRY OUT.12. UNCONTAMINATED CARPETING IN WORK AREAS SHALL BE PROTECTED ORREMOVED PRIOR TO REMOVAL OF ACM. ASBESTOS-CONTAMINATED CARPETING SHALLBE DISPOSED OF AS ACM DURING REMOVAL OF OTHER ACM MATERIALS.13. ALL SYSTEMS WHICH MAY BE DISTURBED IN THE PERFORMANCE OF THE WORK,LOCATED EITHER INSIDE OR OUTSIDE OF THE WORK AREA, INCLUDING BUT NOTLIMITED TO ALL WIRES, CABLES, CONDUITS, ELECTRICAL SYSTEM, PLUMBING SYSTEM,SPEAKER SYSTEM, FIRE ALARM SYSTEM, SMOKE ALARM SYSTEM, COMPUTER SYSTEM,TELECOMMUNICATIONS SYSTEM, CLOCK SYSTEM, DATA SYSTEM, NETWORK SYSTEM,ETC., SHALL BE PROTECTED FROM DAMAGE. SUPPORT CEILING AND WALL MOUNTEDSYSTEMS AS NECESSARY TO PREVENT DAMAGE DURING THE PERFORMANCE OF THEWORK. CABLE TIE TO STRUCTURE EVERY 6' - 10', OR IN ACCORDANCE WITHAPPLICABLE CODES. ANY DAMAGE TO SYSTEMS DURING THE PERFORMANCE OFASBESTOS ABATEMENT IS THE RESPONSIBILITY OF THE ABATEMENT CONTRACTOR.PLANNORTH3/32" = 1' - 0"FIRST AND SECOND LEVEL PLAN13/32" = 1' - 0"BASEMENT LEVEL PLAN2PLANNORTHAPAPAPAPAPAPAR1AR1AR1AR1AR1AR1AR1AR1AR5AR5AR2AR2AR2AR2AR2AR2AR2AR2AR2ASBESTOS ABATEMENT GENERAL NOTES2'X2' ACCESS PANELS:EXISTING FIRE RATED ACCESS PANEL.2'X2' ACCESS PANELS:NEW FIRE RATED ACCESS PANEL TO ACCOMMODATE NEW WORK.AR1 - REMOVAL OF ACM JOINT COMPOUND: COMPLETELY REMOVE ALL ACMJOINT COMPOUND FROM THE AREAS IDENTIFIED ON THE CONTRACT DRAWINGS.ACM JOINT COMPOUND REMOVAL IS SCHEDULED AT ALL DOORS SCHEDULEDFOR REMOVAL, AT DESIGNATED CORRIDOR CEILING / WALL AREAS AND AT RHDROOMS.APAR5 -A.REMOVAL OF DUMBWAITER SHAFT MASTIC/ADHESIVE: COMPLETELYREMOVE ALL ACM DUMBWAITER SHAFT MASTIC/ADHESIVE FROM THEAREAS IDENTIFIED ON THE CONTRACT DRAWINGS. COMPLETE REMOVALINCLUDES ALL LAYERS OF MASTIC/ADHESIVE TO SUBSTRATE TO ENSURECOMPLETE REMOVAL OF THE ACM MASTIC/ADHESIVE.B.PIPE FITTING INSULATION: SPRAY WITH A MIST OF AMENDED WATER OR REMOVAL ENCAPSULANT. ALLOW AMENDED WATER OR REMOVAL ENCAPSULANT TO SATURATE MATERIAL TO SUBSTRATE. IF A REMOVAL ENCAPSULANT IS USED, USE IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. REMOVE JOB-MOLDED FITTING INSULATION IN CHUNKS AND HAND PLACE IN A DISPOSAL BAG. DO NOT DROP TO FLOOR. REMOVE ANY RESIDUE ON PIPE OR FITTING WITH STIFFBRISTLE NYLON HAND BRUSH. IN LOCATIONS WHERE PIPE FITTING INSULATION IS REMOVED FROM PIPE WITH STRAIGHT RUNS INSULATED WITH FIBROUS GLASS OR OTHER NON-ASBESTOS-CONTAINING FIBROUS MATERIAL, REMOVE FIBROUS MATERIAL 6" FROM THE POINT WHERE IT CONTACTS THE ASBESTOS-CONTAINING INSULATION.C.REMOVAL OF DUMBWAITER SHAFT JOINT COMPOUND - COMPLETELYREMOVE ALL ACM DUMBWAITER SHAFT JOINT COMPOUND THE AREASIDENTIFIED ON THE CONTRACT DRAWINGS. COMPLETE REMOVAL INCLUDESCOMPOUND AND SHEETROCK SHAFT WALL ASSEMBLY IN ITS ENTIRETY TOALLOW COMPLETE REPLACEMENT OF THE SHAFT WALLS.AR2 - REMOVAL OF ACM FIRE DOORS: COMPLETELY REMOVE ALL ACM FIREDOORS FROM THE AREAS IDENTIFIED ON THE CONTRACT DRAWINGS. FIREDOORS SHALL BE WRAPPED WITH TWO (2) LAYERS OF AT LEAST 6-MIL POLY ANDDISPOSED OF IN ACCORDANCE WITH APPLICABLE REGULATIONS. ACM FIREDOOR REMOVAL ALSO INCLUDES ASSOCIATED ACM WINDOW GLAZING ANDDOOR FRAME CAULK. DOORS SCHEDULED FOR REMOVAL INCLUDES JOINTCOMPOUND AND SHEETROCK ASSEMBLY IN ITS ENTIRETY TO THE FIRST STUD TOALLOW DOOR / FRAME ASSEMBLY REMOVAL. COORDINATE ALL WORK WITH THEGENERAL CONTRACTOR.ASBESTOS ABATEMENT KEYED NOTESAND LEGEND1AR1-AAR1-BAR1
UPDN645464046404A645364526400CD64516400TD6400TC64646463646264616400CC6424642364226400CA6400CB6400TB6400TA64146413641264116421640264056400J64066400CK6400CH640164036400EA6400644164316400CG6400CF6442644364446434643364326400TF6400TE630263416300CE633163016300J6400EB6400CJ63066332633363346344634363426300CG6300CF6300TE6300TF632163116300CA6300CB6322632363246314631363126300TA6300TB635163616300CD6300CC6352635363546364636363626300TD6300TCDNUPDNUPDNUPDNUPDNUPDNDNDNDNDNDNUPDNDNDNDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGDWELLINGCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETTOILETKITCHENKITCHENJANITORCLOSETJANITORCLOSETLOUNGELOUNGELOUNGETOILETTOILET6400SFFIREESCAPE 36400SCSTAIR 36400SEFIREESCAPE 36400SBSTAIR 36400SASTAIR A6300SBSTAIR B6400SDFIREESCAPE 263POSSTAIR B6300SDFIREESCAPE 16300SCSTAIR 46300SFFIREESCAPE 46300SEFIREESCAPE 46300SBSTAIR 464POSSTAIR A6400CECORRIDORDATE:ISSUESHEET TITLEPROJECTPHASE 5LOWRISE 6 INTERIORMODIFICATIONS1ISSUED FOR BID2019-03-12SCALE:APPROVED BY:PROJECT MGR:IBI PROJECT NO:SHEET NUMBER237 JESSUP ROAD, ITHACA, NEW YORK 14850PRIME CONSULTANTCLIENTCOPYRIGHTISSUESCORNELLUNIVERSITYThis drawing has been prepared solely for the intended use, thus anyreproduction or distribution for any purpose other than authorized by IBI Group isforbidden. Written dimensions shall have precedence over scaled dimensions.Contractors shall verify and be responsible for all dimensions and conditions onthe job, and IBI Group shall be informed of any variations from the dimensions andconditions shown on the drawing. Shop drawings shall be submitted to IBI Groupfor general conformance before proceeding with fabrication.is a member of the IBI Group of companiesIBI GROUP ARCHITECTS, ENGINEERS, & LANDSCAPE ARCHITECTSKEYPLANCHECKED BY:DRAWN BY:SCALE CHECK CONSULTANTSSEAL10mm1 in 59-61 Court Street,Binghamton, NY 13901-1956, USAtel 607 772 0007 fax 607 723 4121IBI GROUPibigroup.comCLIENT PROJECT NO:ITHACA, NEW YORK 14850LOWRISE 6 AND 9IMPROVEMENTS ANDCODE REMEDIATION114475--AS NOTED2019-11-22PLANNORTHLOW RISE 6LEVEL 3 & 4HAZARDOUS MATERIALSPLANLR6-HM101BCDWWWBC3/32" = 1' - 0"THIRD AND FOURTH LEVEL PLAN1PLANNORTH1. INFORMATION PRESENTED ON THESE PLANS AND SPECIFICATIONS IS BASED ONASBESTOS SURVEYS CONDUCTED BY CORNELL UNIVERSITY CONSULTANTS.2. LOCATION OF PERSONAL/WASTE DECONTAMINATION ENCLOSURE SYSTEMS SHALLBE COORDINATED WITH THE OWNER'S REPRESENTATIVE.3. PLAN DIMENSIONS ARE APPROXIMATE AND MUST BE FIELD VERIFIED BY THECONTRACTOR. BIDS SHALL BE BASED SOLELY ON THE CONTRACTOR'S THOROUGHREVIEW OF THE DRAWINGS, SPECIFICATIONS AND SITE CONDITIONS. ANYDISCREPANCIES SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THEOWNER'S REPRESENTATIVE.4. COMPLETENESS OF ABATEMENT IS THE RESPONSIBILITY OF THE ABATEMENTCONTRACTOR. REMOVAL OF ALL ASBESTOS-CONTAINING MATERIALS (ACM) SHALL BETO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE.5. ASBESTOS WORK AREAS ARE IDENTIFIED ON THE CONTRACT DRAWINGS. ALL ACMWITHIN THE WORK AREAS ARE SCHEDULED FOR COMPLETE REMOVAL.6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PETITION THE NEW YORK STATEDEPARTMENT OF LABOR FOR ANY SITE SPECIFIC VARIANCES NECESSARY TOCOMPLETE THE WORK AS SPECIFIED. VARIANCE APPLICATION FEES SHALL BEINCLUDED IN THE BASE BID. ALL VARIANCES ARE SUBJECT TO REVIEW AND APPROVALBY THE OWNER'S REPRESENTATIVE.7. REMOVAL AND CONTAINERIZATION OF ACM SHALL BE COMPLETED IN STRICTACCORDANCE WITH THE STANDARD PROTOCOLS ESTABLISHED BY AHERA 40 CFR 763,NYSDOL ICR 56, OSHA 1926.1101 AND ANY SITE SPECIFIC VARIANCES GRANTED FORTHIS PROJECT INCLUDING, BUT NOT LIMITED TO, DECONTAMINATION AND WASTEREMOVAL PROCEDURES.8. WORK AREAS SHALL BE ISOLATED FROM THE SURROUNDING NON WORK AREAS INACCORDANCE WITH THE SPECIFICATIONS PRESENTED IN SPECIFICATION SECTION002800, AHERA 40 CFR 763, 12 NYCRR PART 56 AND OSHA 1926.1101.9. WORK AREAS SHALL BE PLACARDED WITH SIGNS THAT CONFORM TO OSHA AND 12NYCRR PART 56 STANDARDS. "CAUTION ASBESTOS" TAPE MAY BE USED AT OUTSIDEWORK AREAS. FRAMED AND SHEATHED BARRIERS MAY BE REQUIRED TO KEEPUNAUTHORIZED VISITORS OUT OF INTERIOR WORK AREAS.10. THOROUGHLY WET TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE ALLACM SCHEDULED FOR REMOVAL PRIOR TO STRIPPING AND/OR TOOLING TO REDUCEFIBER DISPERSAL INTO THE AIR.11. REMOVE SATURATED ACM IN SMALL SECTIONS FROM ALL AREAS. DO NOT ALLOWMATERIALS TO DRY OUT.12. UNCONTAMINATED CARPETING IN WORK AREAS SHALL BE PROTECTED ORREMOVED PRIOR TO REMOVAL OF ACM. ASBESTOS-CONTAMINATED CARPETING SHALLBE DISPOSED OF AS ACM DURING REMOVAL OF OTHER ACM MATERIALS.13. ALL SYSTEMS WHICH MAY BE DISTURBED IN THE PERFORMANCE OF THE WORK,LOCATED EITHER INSIDE OR OUTSIDE OF THE WORK AREA, INCLUDING BUT NOTLIMITED TO ALL WIRES, CABLES, CONDUITS, ELECTRICAL SYSTEM, PLUMBING SYSTEM,SPEAKER SYSTEM, FIRE ALARM SYSTEM, SMOKE ALARM SYSTEM, COMPUTER SYSTEM,TELECOMMUNICATIONS SYSTEM, CLOCK SYSTEM, DATA SYSTEM, NETWORK SYSTEM,ETC., SHALL BE PROTECTED FROM DAMAGE. SUPPORT CEILING AND WALL MOUNTEDSYSTEMS AS NECESSARY TO PREVENT DAMAGE DURING THE PERFORMANCE OF THEWORK. CABLE TIE TO STRUCTURE EVERY 6' - 10', OR IN ACCORDANCE WITHAPPLICABLE CODES. ANY DAMAGE TO SYSTEMS DURING THE PERFORMANCE OFASBESTOS ABATEMENT IS THE RESPONSIBILITY OF THE ABATEMENT CONTRACTOR.ASBESTOS ABATEMENT GENERAL NOTESAPAPAPAPAPAPAR1AR1AR1AR1AR1AR2AR2AR2AR2AR2AR2AR2AR2AR2AR2AR2AR5AR5AAR12'X2' ACCESS PANELS:EXISTING FIRE RATED ACCESS PANEL.AR5 -A.REMOVAL OF DUMBWAITER SHAFT MASTIC/ADHESIVE: COMPLETELYREMOVE ALL ACM DUMBWAITER SHAFT MASTIC/ADHESIVE FROM THEAREAS IDENTIFIED ON THE CONTRACT DRAWINGS. COMPLETE REMOVALINCLUDES ALL LAYERS OF MASTIC/ADHESIVE TO SUBSTRATE TO ENSURECOMPLETE REMOVAL OF THE ACM MASTIC/ADHESIVE.B.PIPE FITTING INSULATION: SPRAY WITH A MIST OF AMENDED WATER OR REMOVAL ENCAPSULANT. ALLOW AMENDED WATER OR REMOVAL ENCAPSULANT TO SATURATE MATERIAL TO SUBSTRATE. IF A REMOVAL ENCAPSULANT IS USED, USE IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. REMOVE JOB-MOLDED FITTING INSULATION IN CHUNKS AND HAND PLACE IN A DISPOSAL BAG. DO NOT DROP TO FLOOR. REMOVE ANY RESIDUE ON PIPE OR FITTING WITH STIFFBRISTLE NYLON HAND BRUSH. IN LOCATIONS WHERE PIPE FITTING INSULATION IS REMOVED FROM PIPE WITH STRAIGHT RUNS INSULATED WITH FIBROUS GLASS OR OTHER NON-ASBESTOS-CONTAINING FIBROUS MATERIAL, REMOVE FIBROUS MATERIAL 6" FROM THE POINT WHERE IT CONTACTS THE ASBESTOS-CONTAINING INSULATION.C.REMOVAL OF DUMBWAITER SHAFT JOINT COMPOUND - COMPLETELYREMOVE ALL ACM DUMBWAITER SHAFT JOINT COMPOUND THE AREASIDENTIFIED ON THE CONTRACT DRAWINGS. COMPLETE REMOVAL INCLUDESCOMPOUND AND SHEETROCK SHAFT WALL ASSEMBLY IN ITS ENTIRETY TOALLOW COMPLETE REPLACEMENT OF THE SHAFT WALLS.AR2 - REMOVAL OF ACM FIRE DOORS: COMPLETELY REMOVE ALL ACM FIREDOORS FROM THE AREAS IDENTIFIED ON THE CONTRACT DRAWINGS. FIREDOORS SHALL BE WRAPPED WITH TWO (2) LAYERS OF AT LEAST 6-MIL POLY ANDDISPOSED OF IN ACCORDANCE WITH APPLICABLE REGULATIONS. ACM FIREDOOR REMOVAL ALSO INCLUDES ASSOCIATED ACM WINDOW GLAZING ANDDOOR FRAME CAULK. DOORS SCHEDULED FOR REMOVAL INCLUDES JOINTCOMPOUND AND SHEETROCK ASSEMBLY IN ITS ENTIRETY TO THE FIRST STUD TOALLOW DOOR / FRAME ASSEMBLY REMOVAL. COORDINATE ALL WORK WITH THEGENERAL CONTRACTOR.AR6 - PIPE FITTING INSULATION: SPRAY WITH A MIST OF AMENDED WATER ORREMOVAL ENCAPSULANT. ALLOW AMENDED WATER OR REMOVAL ENCAPSULANTTO SATURATE MATERIAL TO SUBSTRATE. IF A REMOVAL ENCAPSULANT IS USED,USE IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. REMOVEJOB-MOLDED FITTING INSULATION IN CHUNKS AND HAND PLACE IN A DISPOSALBAG. DO NOT DROP TO FLOOR. REMOVE ANY RESIDUE ON PIPE OR FITTING WITHSTIFF BRISTLE NYLON HAND BRUSH. IN LOCATIONS WHERE PIPE FITTINGINSULATION IS REMOVED FROM PIPE WITH STRAIGHT RUNS INSULATED WITHFIBROUS GLASS OR OTHER NON-ASBESTOS-CONTAINING FIBROUS MATERIAL,REMOVE FIBROUS MATERIAL 6" FROM THE POINT WHERE IT CONTACTS THEASBESTOS-CONTAINING INSULATION.ASBESTOS ABATEMENT KEYED NOTESAND LEGEND2'X2' ACCESS PANELS:NEW FIRE RATED ACCESS PANEL TO ACCOMMODATE NEW WORK.AR1 - REMOVAL OF ACM JOINT COMPOUND: COMPLETELY REMOVE ALL ACMJOINT COMPOUND FROM THE AREAS IDENTIFIED ON THE CONTRACT DRAWINGS.ACM JOINT COMPOUND REMOVAL IS SCHEDULED AT ALL DOORS SCHEDULEDFOR REMOVAL, AT DESIGNATED CORRIDOR CEILING / WALL AREAS AND AT RHDROOMS.A.RHD ROOMS REMOVAL INCLUDES JOINT COMPOUND AND SHEETROCKWALL ASSEMBLY AS NECESSARY TO COMPLETE DEVICE REMOVAL /INSTALLATION AND DEMOLITION / RENOVATION WORK. COORDINATE ALLASBESTOS ABATEMENT WORK WITH THE RESPECTIVE TRADES.B.REMOVE 4' X 4' GYPSUM WALLBOARD AND ASSOCIATED ACM JOINTCOMPOUND FOR 2' X 2' ACCESS PANEL INSTALLATION.APAR1-AAR1-B