Loading...
HomeMy WebLinkAbout6-19-20 Ithaca Comcheck submitted to cityCOMcheck Software Version 4.1.1.0 Envelope Compliance Certificate Project Title: 2018 IECC Project Type:New Construction Vertical Glazing / Wall Area:17% Location:Ithaca, New York Climate Zone:6a Construction Site: 323 Elmira Road Ithaca, NY 14850 Owner/Agent: Larry Tyson Sonbyrne Sales, Inc 171 NY-5 Weedsport, NY 13166 315 214 6455 larry.tyson@brynedairy.com Designer/Contractor: Lee Aylesworth Donahoe Group 4503 NW Townline Road Marcellus, NY 13108 315 673 2883 lee@donahoegroup.com Project Information Energy Code: Energy Compliance Report High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Additional Efficiency Package(s) Building Area Floor Area 1-Retail (Retail) : Nonresidential 3088 2-Storage/Cooler (Retail) : Nonresidential 1227 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof 1: Attic Roof with Wood Joists, [Bldg. Use 1 - Retail]3088 49.0 0.0 0.021 0.021 Roof 2: Attic Roof with Wood Joists, [Bldg. Use 2 - Storage/Cooler]1227 49.0 0.0 0.021 0.021 NORTH Exterior Wall 1: Steel-Framed, 24" o.c., [Bldg. Use 1 - Retail]633 15.0 7.5 0.058 0.064 Window 1: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID t14000, SHGC 0.64, PF 0.86, VT 0.80, [Bldg. Use 1 - Retail] (b) 178 ------0.360 0.360 Door 5: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID t14000, SHGC 0.40, PF 0.55, VT 0.60, [Bldg. Use 1 - Retail] (b) 24 ------0.380 0.770 EAST Exterior Wall 4: Steel-Framed, 24" o.c., [Bldg. Use 1 - Retail]590 15.0 7.5 0.058 0.064 Window 6: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID t14000, SHGC 0.64, PF 0.86, VT 0.80, [Bldg. Use 1 - Retail] (b) 146 ------0.360 0.360 Door 4: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID t14000, SHGC 0.40, PF 0.55, VT 0.60, [Bldg. Use 1 - Retail] (b) 48 ------0.380 0.770 SOUTH Exterior Wall 3: Steel-Framed, 24" o.c., [Bldg. Use 1 - Retail]633 21.0 0.0 0.090 0.064 Window 5: Metal Frame with Thermal Break:Fixed, Perf. Specs.:13 ------0.360 0.360 Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 221 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Product ID t14000, SHGC 0.64, PF 0.55, VT 0.80, [Bldg. Use 1 - Retail] (b) Door 2: Insulated Metal, Swinging, [Bldg. Use 1 - Retail]26 ------0.380 0.370 WEST Exterior Wall 2: Steel-Framed, 24" o.c., [Bldg. Use 1 - Retail]590 15.0 7.5 0.058 0.064 (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Lee Aylesworth - Project Manager Name - Title Signature Date Envelope PASSES: Design 5% better than code Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 222 ofPage COMcheck Software Version 4.1.1.0 Interior Lighting Compliance Certificate Project Title: 2018 IECC Project Type:New Construction Construction Site: 323 Elmira Road Ithaca, NY 14850 Owner/Agent: Larry Tyson Sonbyrne Sales, Inc 171 NY-5 Weedsport, NY 13166 315 214 6455 larry.tyson@brynedairy.com Designer/Contractor: Lee Aylesworth Donahoe Group 4503 NW Townline Road Marcellus, NY 13108 315 673 2883 lee@donahoegroup.com Project Information Energy Code: Energy Compliance Report High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Additional Efficiency Package(s) Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Retail (Retail)3088 1.06 3273 2-Storage/Cooler (Retail)1227 1.06 1301 4574Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-Retail (Retail) LED 1: CREE: CR24 40L 40K S: LED Panel 40W:1 10 40 400 LED 3: CREE: CR14 40L 40K S: LED Panel 40W:1 26 40 1040 LED 4: CREE: CR22 32L 40K S: LED Panel 33W:1 34 32 1088 2-Storage/Cooler (Retail) LED 2: CREE: CRLE 40L 40K S SMK: LED Panel 40W:1 13 40 520 3048Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Lee Aylesworth - Project Manager Name - Title Signature Date Interior Lighting PASSES: Design 33% better than code Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 223 ofPage COMcheck Software Version 4.1.1.0 Mechanical Compliance Certificate Project Title: 2018 IECC Project Type:New Construction Location:Ithaca, New York Climate Zone:6a Construction Site: 323 Elmira Road Ithaca, NY 14850 Owner/Agent: Larry Tyson Sonbyrne Sales, Inc 171 NY-5 Weedsport, NY 13166 315 214 6455 larry.tyson@brynedairy.com Designer/Contractor: Lee Aylesworth Donahoe Group 4503 NW Townline Road Marcellus, NY 13108 315 673 2883 lee@donahoegroup.com Project Information Energy Code: Energy Compliance Report High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Additional Efficiency Package(s) Mechanical Systems List Quantity System Type & Description Single Package Heat Pump Heating Mode: Capacity = 160 kBtu/h, Proposed Efficiency = 3.63 COP, Required Efficiency = 3.63 COP Cooling Mode: Capacity = 92 kBtu/h, , Air Economizer Proposed Efficiency = 12.10 EER, Required Efficiency: 12.10 EER + 13.2 IEER Fan System: FAN SYSTEM 1 | Retail -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 3000 CFM, 2.8 motor nameplate hp, 80.0 fan efficiency grade 1 HVAC System 1 (Single Zone): Single Package Heat Pump Heating Mode: Capacity = 65 kBtu/h, Proposed Efficiency = 8.80 HSPF, Required Efficiency = 8.80 HSPF Cooling Mode: Capacity = 59 kBtu/h, , Air Economizer Proposed Efficiency = 15.40 SEER, Required Efficiency: 15.40 SEER Fan System: FAN SYSTEM 2 | Retail Kitchen -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 2 Supply, Constant Volume, 240 CFM, 2.8 motor nameplate hp, 80.0 fan efficiency grade 1 HVAC System 2 (Single Zone): Gas Instantaneous Water Heater, Capacity: 0 gallons, Input Rating: 75 kBtu/h w/ Circulation Pump No minimum efficiency requirement applies 1 Water Heater 2: Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 224 ofPage Lee Aylesworth - Project Manager Name - Title Signature Date Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 225 ofPage Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.1.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2018 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR1]1 Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Complies Does Not Not Observable Not Applicable Requirement will be met. C103.2 [PR2]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Complies Does Not Not Observable Not Applicable Requirement will be met. C103.2 [PR3]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. Complies Does Not Not Observable Not Applicable Requirement will be met. C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.4.1 [PR10]1 The vertical fenestration area <= 30 percent of the gross above-grade wall area. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.4.1 [PR11]1 The skylight area <= 3 percent of the gross roof area. Complies Does Not Not Observable Not Applicable Requirement will be met. C406 [PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 226 ofPage Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 227 ofPage Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions C303.2.1 [FO6]1 Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.12.2 , C403.12.3 [FO9]3 Snow/ice melting system and freeze protection systems have sensors and controls configured to limit service for pavement temperature and outdoor temperature. future connection to controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 228 ofPage Section # & Req.ID Framing / Rough-In Inspection Complies?Comments/Assumptions C303.1.3 [FR12]2 Fenestration products rated in accordance with NFRC. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.1.3 [FR13]1 Fenestration products are certified as to performance labels or certificates provided. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.4.3 [FR10]1 Vertical fenestration SHGC value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.3, C402.4.3. 4 [FR8]1 Vertical fenestration U-Factor.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.4 [FR14]2 U-factor of opaque doors associated with the building thermal envelope meets requirements. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 2.1 [FR19]1 The building envelope contains a continuous air barrier that is sealed in an approved manner and material permeability <= 0.004 dfm/ft2. Air barrier penetrations are sealed in an approved manner. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.2, C402.5.4 [FR18]3 Factory-built fenestration and doors are labeled as meeting air leakage requirements. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.5.7 [FR17]3 Vestibules are installed on all building entrances. Doors have self-closing devices. Complies Does Not Not Observable Not Applicable Exception: Doors that open directly from a space =3000 ft2. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 229 ofPage Section # & Req.ID Plumbing Rough-In Inspection Complies?Comments/Assumptions C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable Requirement will be met. C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable Requirement will be met. C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable Requirement will be met. C404.6.1, C404.6.2 [PL3]1 Automatic time switches installed to automatically switch off the recirculating hot-water system or heat trace. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.7 [PL8]3 Demand recirculation water systems have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.7 [PL8]3 Demand recirculation water systems have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.7 [PL8]3 Demand recirculation water systems have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 2210 ofPage 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 2211 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C402.2.6 [ME41]3 Thermally ineffective panel surfaces of sensible heating panels have insulation >= R-3.5. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.5, C403.2.4. 3 [ME3]3 Stair and elevator shaft vents have motorized dampers that automatically close. Refernece section C403.7.7 for operational details. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.8.4 [ME142]2 Motors for fans that are not less than 1/12 hp and less than 1 hp are electronically commutated motors or have a minimum motor efficiency of 70 percent. These motors have the means to adjust motor speed. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.8.4 [ME142]2 Motors for fans that are not less than 1/12 hp and less than 1 hp are electronically commutated motors or have a minimum motor efficiency of 70 percent. These motors have the means to adjust motor speed. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.8.5 [ME143]2 Each DX cooling system > 65 kBtu and chiller water/evaporative cooling system with fans > 1/4 hp are designed to vary the indoor fan airflow as a function of load and comply with detailed requirements of this section. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.8.5 [ME143]2 Each DX cooling system > 65 kBtu and chiller water/evaporative cooling system with fans > 1/4 hp are designed to vary the indoor fan airflow as a function of load and comply with detailed requirements of this section. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.12.1 [ME71]2 Systems that heat outside the building envelope are radiant heat systems controlled by an occupancy sensing device or timer switch. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.2.3 [ME55]2 HVAC equipment efficiency verified.Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. C403.5.5 [ME113]2 Fault detection and diagnostics installed with air-cooled unitary DX units having economizers. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.5.5 [ME113]2 Fault detection and diagnostics installed with air-cooled unitary DX units having economizers. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.2 [ME59]1 Natural or mechanical ventilation is provided in accordance with International Mechanical Code Chapter 4. Mechanical ventilation has capability to reduce outdoor air supply to minimum per IMC Chapter 4. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 2212 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C403.7.1 [ME59]1 Demand control ventilation provided for spaces >500 ft2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.7.2 [ME115]3 Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50% or less of design capacity. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.7.6 [ME141]3 HVAC systems serving guestrooms in Group R-1 buildings with > 50 guestrooms: Each guestroom is provided with controls that automatically manage temperature setpoint and ventilation (see sections C403.7.6.1 and C403.7.6.2). Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.7.4 [ME57]1 Exhaust air energy recovery on systems meeting Table C403.7.4(1) and C403.7.4(2). Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.7.5 [ME116]3 Kitchen exhaust systems comply with replacement air and conditioned supply air limitations, and satisfy hood rating requirements and maximum exhaust rate criteria. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.11.1 , C403.11.2 [ME60]2 HVAC ducts and plenums insulated in accordance with C403.11.1 and constructed in accordance with C403.11.2, verification may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.5, C403.5.1, C403.5.2 [ME62]1 Air economizers provided where required, meet the requirements for design capacity, control signal, ventilation controls, high-limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.5, C403.5.1, C403.5.2 [ME62]1 Air economizers provided where required, meet the requirements for design capacity, control signal, ventilation controls, high-limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.5.3. 3 [ME124]1 Air economizers automatically reduce outdoor air intake to the design minimum outdoor air quantity when outdoor air intake will not reduce cooling energy usage. See Table C403.5.3.3 for applicable device types and climate zones. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.5.3. 3 [ME124]1 Air economizers automatically reduce outdoor air intake to the design minimum outdoor air quantity when outdoor air intake will not reduce cooling energy usage. See Table C403.5.3.3 for applicable device types and climate zones. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 2213 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C403.5.3. 4 [ME125]1 System capable of relieving excess outdoor air during air economizer operation to prevent overpressurizing the building. The relief air outlet located to avoid recirculation into the building. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.5.3. 4 [ME125]1 System capable of relieving excess outdoor air during air economizer operation to prevent overpressurizing the building. The relief air outlet located to avoid recirculation into the building. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.5.3. 5 [ME126]1 Return, exhaust/relief and outdoor air dampers used in economizers have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Reference section C403.7.7 for details. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.5.3. 5 [ME126]1 Return, exhaust/relief and outdoor air dampers used in economizers have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Reference section C403.7.7 for details. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.4.3. 3.2 [ME121]3 Closed-circuit cooling tower within heat pump loop have either automatic bypass valve or lower leakage positive closure dampers. Open-circuit tower within heat pump loop have automatic valve to bypass all heat pump water flow around the tower. Open- or closed-circuit cooling towers used in conjunction with a separate heat exchanger have heat loss by shutting down the circulation pump on the cooling tower loop. Open- or closed circuit cooling towers have a separate heat exchanger to isolate the cooling tower from the heat pump loop, and heat loss is controlled by shutting down the circulation pump on the cooling tower loop. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.4.3. 3.2 [ME121]3 Closed-circuit cooling tower within heat pump loop have either automatic bypass valve or lower leakage positive closure dampers. Open-circuit tower within heat pump loop have automatic valve to bypass all heat pump water flow around the tower. Open- or closed-circuit cooling towers used in conjunction with a separate heat exchanger have heat loss by shutting down the circulation pump on the cooling tower loop. Open- or closed circuit cooling towers have a separate heat exchanger to isolate the cooling tower from the heat pump loop, and heat loss is controlled by shutting down the circulation pump on the cooling tower loop. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 2214 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C403.4.1. 4 [ME63]2 Heating for vestibules and air curtains with integral heating include automatic controls that shut off the heating system when outdoor air temperatures > 45F. Vestibule heating and cooling systems controlled by a thermostat in the vestibule with heating setpoint <= 60F and cooling setpoint >= 80F. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C408.2.2. 1 [ME53]3 Air outlets and zone terminal devices have means for air balancing. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.5, C403.5.1, C403.5.2 [ME123]3 Refrigerated display cases, walk-in coolers or walk-in freezers served by remote compressors and remote condensers not located in a condensing unit, have fan-powered condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 2215 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.2. 2 [EL22]1 Spaces required to have light- reduction controls have a manual control that allows the occupant to reduce the connected lighting load in a reasonably uniform illumination pattern >= 50 percent. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1, C405.2.1. 1 [EL18]1 Occupancy sensors installed in classrooms/lecture/training rooms, conference/meeting/multipurpose rooms, copy/print rooms, lounges/breakrooms, enclosed offices, open plan office areas, restrooms, storage rooms, locker rooms, warehouse storage areas, and other spaces <= 300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1. 2 [EL19]1 Occupancy sensors control function in warehouses: In warehouses, the lighting in aisleways and open areas is controlled with occupant sensors that automatically reduce lighting power by 50% or more when the areas are unoccupied. The occupant sensors control lighting in each aisleway independently and do not control lighting beyond the aisleway being controlled by the sensor. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1. 3 [EL20]1 Occupant sensor control function in open plan office areas: Occupant sensor controls in open office spaces >= 300 sq.ft. have controls 1) configured so that general lighting can be controlled separately in control zones with floor areas <= 600 sq.ft. within the space, 2) automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space, 3) are configured so that general lighting power in each control zone is reduced by >= 80% of the full zone general lighting power within 20 minutes of all occupants leaving that control zone, and 4) are configured such that any daylight responsive control will activate space general lighting or control zone general lighting only when occupancy for the same area is detected. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.2, C405.2.2. 1, C405.2.2. 2 [EL21]2 Each area not served by occupancy sensors (per C405.2.1) have time- switch controls and functions detailed in sections C405.2.2.1 and C405.2.2.2. Complies Does Not Not Observable Not Applicable Exception: Lighting controlled by occupancy sensors. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 2216 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.3, C405.2.3. 1, C405.2.3. 2 [EL23]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. See code section C405.2.3 Daylight-responsive controls for applicable spaces, C405.2.3.1 Daylight responsive control function and section C405.2.3.2 Sidelit zone. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.4 [EL26]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.4 [EL27]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.6 [EL26]2 Low-voltage dry-type distribution electric transformers meet the minimum efficiency requirements of Table C405.6. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.7 [EL27]2 Electric motors meet the minimum efficiency requirements of Tables C405.7(1) through C405.7(4). Efficiency verified through certification under an approved certification program or the equipment efficiency ratings shall be provided by motor manufacturer (where certification programs do not exist). Complies Does Not Not Observable Not Applicable Requirement will be met. C405.8.2, C405.8.2. 1 [EL28]2 Escalators and moving walks comply with ASME A17.1/CSA B44 and have automatic controls configured to reduce speed to the minimum permitted speed in accordance with ASME A17.1/CSA B44 or applicable local code when not conveying passengers. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.9 [EL29]2 Total voltage drop across the combination of feeders and branch circuits <= 5%. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 2217 ofPage Section # & Req.ID Insulation Inspection Complies?Comments/Assumptions C303.1 [IN3]1 Roof insulation installed per manufacturer’s instructions. Blown or poured loose-fill insulation is installed only where the roof slope is <=3 in 12. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.2.1 [IN20]1 Insulation installed on a suspended ceiling having ceiling tiles is not being specified for roor/ceiling assemblies. Continuous insulation board installed in 2 or more layers with edge joints offset between layers. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C303.1 [IN10]2 Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.2 [IN7]1 Above-grade wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.2.1 [IN14]2 Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.2.3 [IN6]1 Above-grade wall insulation R-value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [IN18]3 Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.2.2 [IN2]1 Roof R-value. For some ceiling systems, verification may need to occur during Framing Inspection. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 1 [IN1]1 All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor- permeable wrapping material to minimize air leakage. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 2218 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.3, C408.2.5. 3 [FI8]3 Furnished O&M manuals for HVAC systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo door openings and provide direct contact along the top and sides of vehicles parked in the doorway. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo door openings and provide direct contact along the top and sides of vehicles parked in the doorway. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo door openings and provide direct contact along the top and sides of vehicles parked in the doorway. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo door openings and provide direct contact along the top and sides of vehicles parked in the doorway. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.8 [FI26]3 Recessed luminaires in thermal envelope to limit infiltration and be IC rated and labeled. Seal between interior finish and luminaire housing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.2.2 [FI27]3 HVAC systems and equipment capacity does not exceed calculated loads. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 1 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 1 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 1.1 [FI42]3 Heat pump controls prevent supplemental electric resistance heat from coming on when not needed. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 1.1 [FI42]3 Heat pump controls prevent supplemental electric resistance heat from coming on when not needed. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 2219 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C403.4.1. 2 [FI38]3 Thermostatic controls have a 5 °F deadband. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 1.3 [FI20]3 Temperature controls have setpoint overlap restrictions. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 2 [FI39]3 Each zone equipped with setback controls using automatic time clock or programmable control system. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 2.1, C403.2.4. 2.2 [FI40]3 Automatic Controls: Setback to 55°F (heat) and 85°F (cool); 7-day clock, 2- hour occupant override, 10-hour backup Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 2.3 [FI41]3 Systems include optimum start controls. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 2.3 [FI41]3 Systems include optimum start controls. Complies Does Not Not Observable Not Applicable Requirement will be met. C404.3 [FI11]3 Heat traps installed on supply and discharge piping of non-circulating systems. Complies Does Not Not Observable Not Applicable Requirement will be met. C404.4 [FI25]2 All piping insulated in accordance with section details and Table C403.11.3. Complies Does Not Not Observable Not Applicable Requirement will be met. C404.6.1 [FI12]3 Controls are installed that limit the operation of a recirculation pump installed to maintain temperature of a storage tank. System return pipe is a dedicated return pipe or a cold water supply pipe. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.4.1 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C408.1.1 [FI57]1 Building operations and maintenance documents will be provided to the owner. Documents will cover manufacturers' information, specifications, programming procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and operated. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 2220 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C408.2.1 [FI28]1 Commissioning plan developed by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.3. 1 [FI31]1 HVAC equipment has been tested to ensure proper operation. Complies Does Not Not Observable Not Applicable Exception: Unitary or packaged HVAC eqiupment without supply air economizers. C408.2.3. 2 [FI10]1 HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.3. 3 [FI32]1 Economizers have been tested to ensure proper operation. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.4 [FI29]1 Preliminary commissioning report completed and certified by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.5. 1 [FI7]3 Furnished HVAC as-built drawings submitted within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.5. 1 [FI16]3 Furnished as-built drawings for electric power systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.5. 3 [FI43]1 An air and/or hydronic system balancing report is provided for HVAC systems. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.5. 4 [FI30]1 Final commissioning report due to building owner within 90 days of receipt of certificate of occupancy. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.3 [FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 2221 ofPage Project Title: Data filename: Energy Compliance Report C:\Sharefile\Shared Folders\2020\Byrne Dairy_Ithaca 20010\2.0 Codes & Approvals\2.2 Building Permit\20010_2020 06 18_Comchek.cck 06/19/20Report date: 2222 ofPage