HomeMy WebLinkAbout3207_Low Rise 7 Floor Remediation_100% CD_S&SCB CB CB CB CBCBCB CB CB Village of Cayuga Heights WALL LINE R W 3205 PROGRAM HOUSE DRIVEAREA OF WORK 3206 3208 3207 3209 3209 3212 3201 GEORGE JESSUP ROAD EXTERIOR ELEVATION 1 X-100 X-100 1 1 INTERIOR ELEVATION 1 X-100 SECTION MARKER 1 X-100 ENLARGED DETAIL CONSTRUCTION KEYED NOTE DEMOLITION KEYED NOTE DRAWING REVISION NOTE LINETYPE: TO BE PROVIDED / NEW LINETYPE: DEMOLITION / TO BE RELOCATED LINETYPE: EXISTING TO REMAIN # # # 1 1 1 11 T-001 TITLE SHEET ARCHITECTURAL A-001 GENERAL NOTES, SYMBOLOGY, AND ABBREVIATIONS A-101 FIRST FLOOR RENOVATION PLAN A-102 THIRD FLOOR RENOVATION PLAN A-103 FIRST FLOOR REFLECTED CEILING PLAN ELECTRICAL E-101 ELECTRICAL DEMOLITION & REMOVAL PLANS E-102 ELECTRICAL RENOVATION PLANCORNE LL U N I V E R SI TYFOUN D E D 5681 AD CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 Cornell University 116 PROGRAM HOUSE DR ITHACA, NEW YORK 14850 LOW RISE 7 FLOOD REMEDIATION T-001 12673546 TITLE SHEET FE DESIGN JGC 3207 JUNE 25, 2020 LOW RISE 7 FLOOD REMEDIATION PROJECT CODE SUMMARY GENERAL SYMBOLS LEGEND DRAWING INDEX PROJECT SCOPE THE PURPOSE OF THIS PROJECT IS TO REPAIR THE FLOOD DAMAGE THAT OCCURRED DURING THE SPRING SEMESTER. WORK INCLUDES ELECTRICAL REMOVAL/ REINSTALLATION AND GYPSUM WALL BOARD REINSTALLATION. SITE LOCATION -LOW RISE 7 1 06/15/2020 ISSUE FOR 95% REVIEW 2 06/17/2020 ISSUE FOR COORDINATED REVIEW 3 06/25/2020 ISSUE FOR CONSTRUCTION PROJECT NAME:LOW RISE 7 FLOOD REMEDIATION PROJECT LOCATION: BUILDING NAME:NORTH CAMPUS LOW RISE 7 BUILDING ADDRESS:116 PROGRAM HOUSE DRIVE LOCATION OF PROJECT IN THE BUILDING:1ST AND 3RD FLOORS GENERAL BUILDING INFORMATION: YEAR BUILT: 1975 APPLICABLE CODE TO ORIGINAL BUILDING:STATE BUILDING CONSTRUCTION CODE STORIES:4 HEIGHT IN FEET:40' -2" HIGHRISE: NO AREA OF LARGEST FLOOR:8210 SQFT CONSTRUCTION CLASSIFICATION OF THE BUILDING ACTUAL:2B REQUIRED:2B OCCUPANCY CLASSIFICATION BUILDING:R-2 FIRE PROTECTION SYSTEMS MANUAL FIRE ALARM SYSTEM:YES AUTOMATIC FIRE/SMOKE DETECTION SYSTEM:YES FULL NFPA 13 SPRINKLER SYSTEM:YES REQUIRED:YES STANDPIPES:YES IN EACH EXIT STAIRWAY:YES MANUAL WET:YES CO DETECTION SYSTEM:YES PROJECT DESCRIPTION:THE REPAIR TO WET DRYWALL CAUSED BY A SPRINKLER ACTIVATION ON THE 3RD FLOOR LEVEL. THAT ALSO CAUSED DAMAGE ON THE 1ST FLOOR LEVEL. PROJECT CODE INFORMATION: CONSTRUCTION TYPE REQUIRED:2B PROVIDED:NO STRUCTURAL WORK OCCUPANCY CLASSIFICATION PROJECT SPACE:R-2 APPLICABLE CODES:2020 NYS CODES EXISTING BUILDING CODE PROJECT TYPE:REPAIR WORK AREA DEFINED ON DRAWING:YES, A-001 7100TB7100TAA A B AA A A B A A A B A A A B 7100JC 7100CH7103 7105 7101A 7101 7107 7100JB 7104 7100EA 7100CE 7106 7100JA 7100 7102 7100SB 7132 7133 7134 7100TF7100CG 7131 7141 7100CF 7100TE 7144 71437142 71117121 7100CB7100CA 7123 7122 7124 7114 7113 7112 7100SD 7100SE 7100CJ PATIO 7100EB 7100SA DN UP UPDN UP UPDN B A AA AA B A A B A A B A AA 7300EB 7303 7304 7300CK 7300 7300CE 7300EA 7300SA 7306 7301 7331 7300CA 7300CB 7300TA7300TB7332 7333 73347344 7343 7342 7324 73237322 7321 7311 7312 7313 7314 7300TF 7300TE7300CJ 7300CH 7300SB7307 7300J 7307C 7307E 7307A 7307F 7300CD7307S 7307B7307D 7300SD7300SE UP DN UPDN DN UP DN UP WALL -EXISTING WALL -METAL STUD/ GWB WALL -CONCRETE WALL -CMU WALL -BRICK ITEMS FOR DEMOLITION DOOR/ WALL -EXISTING DOOR/ WALL -NEW DOOR/ WALL -DEMOLITION TAG -DOOR TAG -WINDOW TAG -WALL TAG -ROOM # CENTER LINE PHOTO REFERENCE LEVEL MARKER COLUMN GRID MARKER ELEVATION MARKER ELEVATION CHANGE ARROWS BREAK LINE SYMBOLS 0' -0" 101 1t X-X X 2B00UA CL 1 Name Elevation A101 1 1 1 0 DN UP ABBREVIATIONS A &AND @ AT ACT ACOUSTICAL CEILING TILE ALT ALTERNATE ALUM ALUMINUM AVG AVERAGE AFF ABOVE FINISH FLOOR B BD BOARD BLDG BUILDING BOD BOTTOM OF DECK BSMT BASEMENT C CG CORNER GUARDS CJ CONTROL JOINT CLG CEILING CL CENTER LINE CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONF CONFERENCE CONT CONTINUOUS CORR CORRIDOR CPT CARPET CRS COURSE(S) CT CERAMIC TILE D DEMO DEMOLITION DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DO DOOR OPENING DWG DRAWING E EA EACH EJ EXPANSION JOINT ELEC ELECTRIC ELEV ELEVATION/ ELEVATOR EPDM RUBBER ROOF MEMBRANE EQ EQUAL EX'G EXISTING EXT EXTERIOR F FD FLOOR DRAIN FDN FOUNDATION FEC FIRE EXTINGUISHER CABINET FFE FINISH FLOOR ELEVATION FRP FIBER REINFORCED POLYESTER FT FOOT/FEET FTG FOOTING G GA GAGE GALV GALVANIZED GC GENERAL CONTRACTOR GEN GENERAL GL GLASS GWB GYPSUM WALL BOARD H HC HANDICAPPED HT HEIGHT HM HOLLOW METAL HR HOUR HVAC HEATING, VENTILATING & AC J JAN JANITOR L LAV LAVATORY LB/#POUND LGMF LIGHT GAGE METAL FRAMING M MFR MANUFACTURER MAT MATERIAL MAX MAXIMUM MEZZ MEZZANINE MIN MINIMUM MO MASONRY OPENING MTL METAL N NA NOT APPLICABLE NIC NOT IN CONTRACT NR NOT RATED NTS NOT TO SCALE O OC ON CENTER OD OUTSIDE DIAMETER OPNG OPENING OSB ORIENTER STRAND BOARD P +/-PLUS OR MINUS PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED Q QTY QUANTITY R R RISER RD ROOF DRAIN REF REFRIGERATOR REQ REQUIRED REV REVISION RO ROUGH OPENING RTU ROOF TOP UNIT S SHTG SHEATHING SIM SIMILAR SF SQUARE FOOT/ FEET SS STAINLESS STEEL STL STEEL STD STANDARD T T TREAD T&G TONGUE & GROOVE TEL TELEPHONE TEMP TEMPERATURE TOS TOP OF STEEL TV TELEVISION TYP TYPICAL U UEV UNEVEN DOORS W/ VISION PANEL UEF UNEVEN FLUSH DOOR V VCT VINYL COMPOSITION TILE VIF VERIFY IN FIELD W W/O WITHOUT WD WOOD AREA OF WORK AREA OF WORK CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 116 PROGRAM HOUSE DR ITHACA, NEW YORK 14850 LOW RISE 7 FLOOD REMEDIATION A-001 12673546 GENERAL NOTES, SYMBOLOGY, AND ABBREVIATIONS J. COOLBAUGH JGC 3207 JUNE 25, 2020 SCOPE OF WORK 1.0 PROVIDE NEW GYPSUM WALLBOARD ON WALLS WHERE WET GYP WALL WAS ABATED. 2.0 PROVIDE NEW HOLLOW METAL DOOR LEAVES AND HARDWARE. 3.0 PROVIDE NEW GYPSUM WALLBOARD ON CEILINGS WHERE WET GYP CEILING WAS ABATED. 4.0 PROVIDE NEW TRIM TO MATCH EXISTING. GENERAL NOTES 1.0 DESIGN, CONSTRUCTION AND SAFETY SHALL CONFORM TO ALL LOCAL, STATE AND OWNER SPECIFIC CODES, INCLUDING (BUT NOT LIMITED TO) THE NEW YORK STATE UNIFORM FIRE PROTECTION AND BUILDING CODE, LATEST REVISION, THE NFPA 101 LIFE SAFETY CODE, LATEST REVISION, ANSI A117.1 - LATEST REVISION, OSHA, AND ANY OTHER CODES GOVERNED BY THE JURISDICTION IN WHICH THIS PROJECT IS BEING CONSTRUCTED. 2.0 THIS CONTRACT REQUIRES COMPLETE, FINISHED WORKABLE PROJECT OF THE AREAS INDICATED BY THE CONTRACT DOCUMENTS, AND SHALL INCLUDE ALL MATERIALS AND LABOR NECESSARY TO COMPLETE, REGARDLESS OF WHETHER OR NOT ALL WORK OR EACH ITEM IS SPECIFICALLY INDICATED ON ANY OTHER PORTION OF THE DRAWINGS AND / OR NOTES. 3.0 WHERE MATERIALS REFERENCED ON DRAWINGS, OR NECESSARY TO COMPLETE THE WORK OF THIS CONTRACT ARE NOT SPECIFIED HEREIN, PROVIDE BEST QUALITY MATERIALS. WHERE MATERIALS ARE INTENDED TO MATCH EXISTING, PROVIDE CLOSEST POSSIBLE MATCH, SUBJECT TO OWNER'S APPROVAL. ALL ITEMS AND WORK ON DRAWINGS ARE NEW, UNLESS INDICATED EXISTING. ALL WORK WHICH HAS BEEN DAMAGED SHALL BE REPAIRED OR REPLACED AT NO COST TO THE OWNER. WHERE ITEMS CAN NOT BE REPAIRED TO A ""NEW CONDITION"", OR WHERE THE STRUCTURAL INTEGRITY HAS BEEN AFFECTED, ITEMS SHALL BE REPLACED AT NO COST TO THE OWNER. 4.0 CONTRACTOR IS RESPONSIBLE TO VERIFY ALL SITE, FIELD AND BUILDING CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. IF THERE ARE ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS, NOTIFY THE PROJECT MANAGER, WHO WILL REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER AND PROVIDE CLARIFICATION IN WRITING. 5.0 WHERE EXISTING CONSTRUCTION OR ITEMS HAVE BEEN INFILLED, REMOVED AND / OR DISTURBED FOR INSTALLATION OF NEW WORK, CAUSING THE EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES RESULTING SURFACES AND INFILLED SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. ALL ABANDONED OPENINGS (i.e. DUCT/PIPE REMOVALS, ETC.) AT WALLS, ROOF OR FLOOR TO BE INFILLED SOLID. 6.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE WORK OF OTHER TRADES (i.e. ELECTRICAL, MECHANICAL). ALTHOUGH NOT NECESSARILY SHOWN ON DRAWINGS, WORK IS REQUIRED IN THESE AREAS CONSISTING OF REMOVAL / REPLACEMENT OF CEILINGS, WALLS, FINISHES, PAVEMENT AND OTHER CONSTRUCTION AS NECESSARY TO PERFORM WORK AND RESTORE THESE SPACES OR AREAS TO ORIGINAL CONDITION. 7.0 GENERAL CONTRACTOR IS TO COORDINATE WORK OF ALL TRADES. SCHEDULE WORK PROGRESS THROUGHOUT THE ENTIRE PROJECT TO PREVENT CONFLICTS AND INTERFERENCES. OBTAIN ALL NECESSARY INFORMATION SUCH AS SIZES, LOCATIONS, TEMPLATES, LAYOUT, DIMENSIONS AND ALL OTHER INFORMATION NECESSARY FOR A PROPER AND WELL COORDINATED INSTALLATION. PRIOR TO INSTALLATION OF ITEMS, VERIFY AND CONFIRM WITH EACH CONTRACTOR EXACT LOCATION OF ALL ITEMS. 8.0 ALL PENETRATIONS (EXISTING OR NEW) THROUGH FLOORS AND FULL HEIGHT WALLS - IN AREA OF WORK TO BE FIRE STOPPED. ALL GAPS AND JOINTS AT RATED FLOORS, ROOFS AND WALLS TO BE FIRE & SMOKE STOPPED. GAPS AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND CONTROL OR EXPANSION JOINTS. FIRE STOPPING INCLUDES BOTH FORM OR PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. PROVIDE AND INSTALL LABELING REQUIRED BY CODE. LABELS SHALL INCLUDE PENETRATION TYPE WITH UL LISTING USED, MATERIAL USED, DATE INSTALL AND NAME OF INSTALLER. 9.0 JOBSITE WILL BE CLEANED DAILY AND DEBRIS REMOVED TO CONTAINERS OR TO VEHICLE WHICH WILL REMOVE DEBRIS FROM CAMPUS. CONTAINERS WILL BE REMOVED AS SOON AS FULL OR WHEN THE PROJECT HAS PROGRESSED TO A POINT THAT A CONTAINER IS NO LONGER REQUIRED. 10.0 CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL AREAS USED TO BRING SUPPLIES AND EQUIPMENT INTO THE PROJECT AREA. ANY DAMAGE TO AREAS OUTSIDE THE PROJECT AREA INCLUDING BUT NOT LIMITED TO THE LOBBY AND CORRIDOR SHALL BE REPAIRED AT NO COST TO THE OWNER. SCALE: NO SCALE 1 KEY PLAN - FIRST FLOOR SCALE: NO SCALE 2 KEY PLAN - THIRD FLOOR 1 06/15/2020 ISSUE FOR 95% REVIEW 2 06/17/2020 ISSUE FOR COORDINATED REVIEW 3 06/25/2020 ISSUE FOR CONSTRUCTION SUBMITTAL REGISTRY SPECIFICATION SECTION TITLE CATEGORY 08 11 13 HOLLOW METAL DOORS AND FRAMES PRODUCT DATA 08 70 00 HARDWARE PRODUCT DATA 09 21 16 GYPSUM BOARD ASSEMBLIES PRODUCT DATA 09 91 00 PAINTING PRODUCT DATA UPDN UP UPDN 7144 71437142 7141 7100TE 7100TF 7100CF 7100CG 7132 7133 7134 7131 7100CE 7100SD 7106 7100JA 7100 7111 7100EA 7100SA 7143 7144 x 1' - 0" H 4' - 0" W x 1' - 0" H 8' - 0" W x 1' - 0" H 6' - 8" W x 1' - 0" H2' - 10" Wx 4' - 0" H 1' - 9" W x 1' - 0" H 6' - 3" W x 1' - 0" H 4' - 9" W 9" W x 1' -0" H 11" W x 1' -0" H 10" W x 1' -0" H x 2' - 0" H 11' - 5" W x 2' - 0" H3' - 0" Wx 2' - 0" H12' - 7" Wx 2' - 0" H 7' - 2" W x 8' - 7" H3' - 2" Wx 2' - 0" H11" Wx 4' - 0" H10' - 3" W9" W x 2' -0" H 11" W x 2' -0" H 11" W x 2' -0" H 9" W x 2' -0" H 6" W x 2' -0" H4" W x 1' -0" H x 1' - 0" H 6' - 3" W 1 2 3 3 1 2 1 2 1 2 1 2 1 2 1 2 4 4 2 x 1' - 0" H3' - 2" Wx 1' - 0" H11' - 10" W1 2 NOTE: ALL HEIGHT DIMENSIONS ARE FROM FINISH FLOOR UP THE WALL TO THE CEILING. VERIFY ALL DIMENSIONS IN FEILD. D1 HOLLOW METAL DOORS: • DOORS BY CURRIES OR APPROVED EQUAL 1. 18 GAGE MIN. 2. VERIFY EXISTING FIRE RATING • NEW DOOR HARDWARE (HINGES, LOCKSET, ECT.) TO BE PURCHASED FROM CU LOCK SHOP. COORDINATE HARDWARE REQUIREMENTS WITH SCL LOCK SHOP FOR NEW DOORS. 32"80"CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 116 PROGRAM HOUSE DR ITHACA, NEW YORK 14850 LOW RISE 7 FLOOD REMEDIATION A-101 12673546 FIRST FLOOR RENOVATION PLAN J. COOLBAUGH JGC 3207 JUNE 25, 2020 A-101 KEYED RENOVATION NOTES 1 PROVIDE NEW (TYPE X) GYPSUM WALLBOARD. MATCH EXISTING THICKNESS. ASSUME ALL EXISTING GYPSUM WALLBOARD SYSTEMS ARE RATED ASSEMBLIES (W/ 2 OR 3 MULTIPLE SHEETS), STAGER JOINTS AT EACH LAYER OF GYPSUM BOARD. TAPE AND SPACKLE ALL JOINTS. ON FINAL LAYER OF GYPSUM WALLBOARD, FEATHER JOINTS TO SMOOTH FOR A LEVEL 4 FINISH. SAND, PRIME, AND PAINT (2 COATS) ENTIRE ROOM TO MATCH EXISTING COLOR. PATCH ANY OTHER IMPERFECTIONS IN WALL SURFACES NOT BEING REPLACED. 2 REINSTALL 2" x 3/4" WOOD BASE TRIM. IF TRIM IS MISSING, PROVIDE NEW TRIM TO MATCH EXISTING. 3 SAND, PRIME AND PAINT (2 COATS) EXISTING DOOR FRAME. COLOR TO MATCH EXISTING. 4 PROVIDE NEW HOLLOW METAL DOORS. PRIME AND PAINT (2 COATS) - COLOR AS SELECTED BY OWNER. # 0' 2' 4' 8' SCALE: 1/4"=1'-0" SCALE:1/4" = 1'-0"1 RENOVATION PLAN - FIRST FLOOR A-101 GENERAL CONSTRUCTION NOTES 1.0 CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO THE START OF CONSTRUCTION. 2.0 CONTRACTOR SHALL COORDINATE INSTALLATION WITH ALL ASSOCIATED SUBCONTRACTORS PRIOR TO THE START OF CONSTRUCTION. 3.0 CONTRACTOR IS RESPONSIBLE TO REPAIR ANY DAMAGED SUSTAINED TO ADJACENT EXISTING CONDITIONS DURING THE REMOVAL/ INSTALLATION OF BUILDING ELEMENTS. SCALE:1/4" = 1'-0"2 DOOR ELEVATION 1 06/15/2020 ISSUE FOR 95% REVIEW 2 06/17/2020 ISSUE FOR COORDINATED REVIEW 3 06/25/2020 ISSUE FOR CONSTRUCTION UP DN UPDN DN UP 732473237322 7321 7300TF 7300TE 7300CH 7300CJ 7312 7313 7314 7311 7300SB 7300SE 7306 7301 7300CE 7300SA 7300CD7307E 7307F 7307B7300J 7323 9" W x 1' -0" H 3 2 x 1' - 0" H 15' - 10" W x 1' - 0" H11' - 7" Wx 1' - 0" H2' - 10" Wx 1' - 0" H5' - 1"x 1' - 0" H6' - 4" Wx 1' - 0" H5' - 7" Wx 1' - 0" H8' - 4"x 1' - 0" H 1' - 10" W x 1' - 0" H6' - 9" Wx 1' - 0" H 1' - 9" W2 x 1' - 0" H 6' - 6" W x 1' - 0" H 7' - 11" W x 1' - 0" H2' - 8" Wx 1' - 0" H3' - 8" Wx 1' - 0" H12' - 6" Wx 1' - 0" H 4' - 10" Wx 1' - 0" H12' - 4" Wx 1' - 0" H 4' - 10" Wx 1' - 0" H12' - 6" Wx 1' - 0" H 6' - 3" W x 1' - 0" H12' - 4" W2 2 11" W x 1' -0" H 10" W x 1' -0" H x 8' - 6" H 5' - 4" W x 1' - 0" H 4' - 0" W x 8' - 6" H 5' - 0" x 1' - 0" H 4' - 4" W x 1' - 0" H12' - 8" Wx 1' - 0" H 7' - 0" W x 1' - 0" H14' - 7" Wx 1' - 0" H 11' - 3" W x 1' - 0" H3' - 2" W9" W x 1' -0" H 11" W x 1' -0" H 9" W x 1' -0" H 10" W x 1' -0" H 10" W x 1' -0" H 2 x 2' - 0" H 17' - 6" W x 2' - 0" H6' - 11" Wx 2' - 0" H7" Wx 2' - 0" H 17' - 7" W 2 4 NOTE: ALL HEIGHT DIMENSIONS ARE FROM FINISH FLOOR UP THE WALL TO THE CEILING. VERIFY ALL DIMENSIONS IN FEILD. 1 1 1 1 1 1 9" W x 1' -0" H CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 116 PROGRAM HOUSE DR ITHACA, NEW YORK 14850 LOW RISE 7 FLOOD REMEDIATION A-102 12673546 THIRD FLOOR RENOVATION PLAN J. COOLBAUGH JGC 3207 JUNE 25, 2020 0' 2' 4' 8' SCALE: 1/4"=1'-0" SCALE:1/4" = 1'-0"1 RENOVATION PLAN - THIRD FLOOR 1 06/15/2020 ISSUE FOR 95% REVIEW 2 06/17/2020 ISSUE FOR COORDINATED REVIEW 3 06/25/2020 ISSUE FOR CONSTRUCTION A-102 KEYED RENOVATION NOTES 1 PROVIDE NEW (TYPE X) GYPSUM WALLBOARD. MATCH EXISTING THICKNESS. ASSUME ALL EXISTING GYPSUM WALLBOARD SYSTEMS ARE RATED ASSEMBLIES (W/ 2 OR 3 MULTIPLE SHEETS), STAGER JOINTS AT EACH LAYER OF GYPSUM BOARD. TAPE AND SPACKLE ALL JOINTS. ON FINAL LAYER OF GYPSUM WALLBOARD, FEATHER JOINTS TO SMOOTH FOR A LEVEL 4 FINISH. SAND, PRIME, AND PAINT (2 COATS) ENTIRE ROOM TO MATCH EXISTING COLOR. PATCH ANY OTHER IMPERFECTIONS IN WALL SURFACES NOT BEING REPLACED. 2 REINSTALL 2" x 3/4" WOOD BASE TRIM. IF TRIM IS MISSING, PROVIDE NEW TRIM TO MATCH EXISTING. 3 SAND, PRIME AND PAINT (2 COATS) EXISTING DOOR FRAME. COLOR TO MATCH EXISTING. 4 PROVIDE NEW HOLLOW METAL DOORS. PRIME AND PAINT (2 COATS) - COLOR AS SELECTED BY OWNER. # UPDN UP UPDN S SS J S FF M MJ F S F F FJJ J CBCB J J S J F 714471437142 7141 7100TE 7100TF 7100CF 7100CG 7132 7133 7134 7131 7100CE 7100SD 7106 7100JA 7100 7111 7100EA 7100SA 8' - 0 1/2" 8' - 2 3/4" 8' - 2 3/4"8' - 2 3/4" 8' - 6 1/2" V.I.F. 4' - 0" +/- V.I.F. 10' - 0" +/- 1 1 1 1 1 2 CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 116 PROGRAM HOUSE DR ITHACA, NEW YORK 14850 LOW RISE 7 FLOOD REMEDIATION A-103 12673546 FIRST FLOOR REFLECTED CEILING PLAN J. COOLBAUGH JGC 3207 JUNE 25, 2020 0' 2' 4' 8' SCALE: 1/4"=1'-0" SCALE:1/4" = 1'-0"1 REFLECTED CEILING PLAN - FIRST FLOOR 1 06/15/2020 ISSUE FOR 95% REVIEW 2 06/17/2020 ISSUE FOR COORDINATED REVIEW 3 06/25/2020 ISSUE FOR CONSTRUCTION A-103 KEYED RENOVATION NOTES 1 PROVIDE NEW GYPSUM BOARD CEILING SYSTEM. MATCH EXISTING THICKNESS AND NUMBER OF LAYERS (IF APPLICABLE). STAGER ALL JOINTS. TAPE AND SPACKLE ALL JOINTS. ON FINAL LAYER OF GYPSUM WALLBOARD, FEATHER JOINTS SMOOTH FOR A LEVEL 4 FINISH. SAND, PRIME, AND PAINT (2 COATS) CEILING TO MATCH EXISTING COLOR. 2 REFER TO ELECTRICAL DRAWING E-101 FOR MORE INFORMATION ON THE LIGHT FIXTURE. UP S SS J S FF M MJ F S F F FJJ J J CB CBCBCB J J S J F UP DN DN UP F M M S S S SS F J F FF J JJ J CB CBCBCB PM 1 2 12 PMPM 12 PM PM PM PM PM 7144 71437142 7141 7100TE 7100TF 7100CF 7100CG7131 7100CE 7100SD 7106 7111 5 4 1 2 3 1 2 3 4 5 4 6 48" AFF 48" AFF 7 ETRETR 8 2 ETR 48" AFF ETR ETR ETR ETR 56" AFF 56" AFF ETRETR ETR ETRETR 56" AFF ETR ETR ETR ETR ETR ETRETR ETR ETR ETR ETR ETR SR SR ETR ETR 48" AFF ETR ETR 4 SR SR SR ETR 56" AFF ETR ETRETR ETR ETR 48" AFF ETR ETR ETR ETR ETR SR ETR SR SR SRSR ETR SR SR 2 1 ETR 6 ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR PM PM PM PM PM PM PM 1 2 1221 4 7324 73237322 7321 7300TF 7300TE 7300CH 7300CJ7311 7300SB 7300SE 7306 7300CD7300J 4 5 4 6 48" AFF SR SRETRETR ETR ETR 48" AFF ETR ETR ETR ETR 44 ETR ETR ETR ETR ETR 5 56" AFF 4 SR 5 ETR ETR ETR ETR ETR ETR 6 4 ETR 48" AFF 6 ETR ETR ETR ETR SR ETR ETR ETR ETR ETR ETR ETRETRETR ETR ETRSR6 ETR 7 8 PM 9 10 10 11 12 13 56" AFF 48" AFF CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 116 PROGRAM HOUSE DR ITHACA, NEW YORK 14850 LOW RISE 7 FLOOD REMEDIATION E-101 12673546 ELECTRICAL DEMOLITION & REMOVAL PLANS M. SCHOLENO MPS 3207 JUNE 25, 2020 SCALE:1/4" = 1'-0"1 ELECTRICAL DEMOLITION & REMOVAL PLAN - 1ST FLOOR SCALE:1/4" = 1'-0"2 ELECTRICAL DEMOLITION & REMOVAL PLAN - 3RD FLOOR E-101 KEYED DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING CEILING MOUNTED LIGHT FIXTURE. PROPERLY TAG AND STORE FOR REUSE. TAG EXISTING CIRCUITRY FOR REUSE. 2 DISCONNECT AND REMOVE EXISTING CEILING MOUNTED SMOKE DETECTOR. PROPERLY TAG AND STORE FOR REUSE. TAG EXISTING CIRCUITRY FOR REUSE. 3 DISCONNECT AND REMOVE EXISTING CEILING JUNCTION BOX AND ASSOCIATED SURFACE RACEWAY. PROPERLY TAG AND STORE FOR REUSE. TAG EXISTING CIRCUITRY FOR REUSE. 4 DISCONNECT AND REMOVE EXISTING PLUGMOLD. PROPERLY TAG AND STORE FOR REUSE. TAG EXISTING CIRCUITRY FOR REUSE. 5 DISCONNECT AND REMOVE EXISTING VOICE/DATA OUTLET. PROPERLY TAG AND STORE FOR REUSE. TAG EXISTING CABLING FOR REUSE. 6 DISCONNECT AND REMOVE EXISTING RECEPTACLE. PROPERLY TAG AND STORE FOR REUSE. TAG EXISTING CIRCUITRY FOR REUSE. 7 DISCONNECT AND REMOVE EXISTING CEILING MOUNTED LIGHT FIXTURE. TAG EXISTING CIRCUIT FOR REUSE WITH NEW LIGHT FIXTURE. 8 DISCONNECT AND REMOVE EXISTING CEILING MOUNTED JUNCTION BOX AND SURFACE RACEWAY BACK TO EXISTING DEVICE ON WALL. TAG EXISTING CIRCUIT FOR REUSE. 9 DISCONNECT AND REMOVE EXISTING CEILING MOUNTED SMOKE DETECTOR. TAG EXISTING CIRCUITRY FOR REUSE WITH NEW SMOKE DETECTOR. 10 DISCONNECT AND REMOVE EXISTING PLUGMOLD. TAG EXISTING CIRCUITRY FOR REUSE WITH NEW PLUGMOLD. 11 DISCONNECT AND REMOVE EXISTING VOICE/DATA OUTLET. TAG EXISTING CABLING FOR REUSE WITH NEW OUTLET.. 12 DISCONNECT AND REMOVE EXISTING RECEPTACLE. TAG EXISTING CIRCUITRY FOR REUSE WITH NEW RECEPTACLE. 13 DISCONNECT AND REMOVE EXISTING LIGHT SWITCH. TAG EXISTING CIRCUITRY FOR REUSE WITH NEW LIGHT SWITCH. # ELECTRICAL ABBREVIATIONS AFF ABOVE FINISHED FLOOR AFI ARC FAULT INTERRUPTER AMM ADDRESSABLE MONITOR MODULE AOM ADDRESSABLE OUTPUT MODULE BKR BREAKER C CONDUIT CD CANDELA CKT CIRCUIT EC ELECTRICAL CONTRACTOR EMT ELECTRICAL METALLIC TUBING EPO EMERGENCY POWER OFF STATION ETR EXISTING TO REMAIN FAA FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL GFI GROUND FAULT INTERRUPTER GND GROUND LC LIGHTING CONTACTOR LFMC LIQUID TIGHT FLEXIBLE METALLIC CONDUIT LTG LIGHTING MCB MAIN CIRCUIT BREAKER MLO MAIN LUG ONLY NAC NOTIFICATION APPLIANCE CIRCUIT NIC NOT IN CONTRACT PC PHOTOCELL PM PLUGMOLD PP POWER PANEL PVC POLYVINYL CHLORIDE CONDUIT RGS RIGID GALVANIZED STEEL CONDUIT SR SURFACE RACEWAY TSP TWISTED SHIELDED PAIR TYP TYPICAL UON UNLESS OTHERWISE NOTED V VOLTS VA VOLT AMPS ELECTRICAL LEGEND MOTOR JUNCTION BOX B = INSTALLED IN BASEBOARD TR = INSTALLED IN WOOD TRIM/CASEWORK/WAINSCOTT SR = SURFACE RACEWAY WP = WEATHERPROOF AC = AIR CONDITIONER DUPLEX RECEPTACLE: DOUBLE DUPLEX RECEPTACLE F FIRE ALARM MANUAL PULL STATION F XXcd C XXcd = CANDELA C = CEILING COMBO A/V NOTIFICATION APPLIANCE: LUMINAIRE -WALL MOUNTED IN CORRIDORS -CEILING MOUNTED IN DORM ROOM CEILING MOUNTED LUMINAIRE D = DUCT SMOKE DETECTOR R = RELAY BASE BR = BEAM RECEIVER BT = BEAM TRANSMITTER SB = SOUNDER BASE SMOKE DETECTOR: S X JJ # # = QUANTITY OF DATA JACKS COMMUNICATIONS OUTLET: 1 06/15/2020 ISSUE FOR 95% REVIEW 2 06/17/2020 ISSUE FOR COORDINATED REVIEW 3 06/25/2020 ISSUE FOR CONSTRUCTION UP S SS J S FF M MJ F S F F FJJ J CB CBCBCB J J S J F UP DN DN UP F M M S S S S F J F FF J J J CB CBCBCB J PM 1 2 12 PMPM 12 PM PM PM PM PM 7144 71437142 7141 7100TE 7100TF 7100CF 7100CG7131 7100CE 7100SD 7106 7111 48" AFF 48" AFF ETRETR ETR 48" AFF ETR ETR 48" AFF ETR ETR 56" AFF 56" AFF ETRETR ETR ETRETR 56" AFF ETR ETR ETR ETR ETR ETRETR ETR ETR ETR ETR ETR SR SR ETR ETR 48" AFF ETR ETR 4 SR SR SR ETR 56" AFF ETR ETRETR ETR ETR 48" AFF ETR ETR ETR ETR ETR SR ETR SR SR 1 2 3 4 5 6 7 8 4 4 5 2 1 2 3 SR SR 6 PM PM PM PM PM PM 1 2 21 4 7324 73237322 7321 7300TF 7300TE 7300CH 7300CJ7311 7300SB 7300SE 7306 7300CD7300J 48" AFF SR SRETRETR ETR ETR 48" AFF ETR ETR ETR ETRETR ETR ETR ETR ETR 56" AFF PM SR ETR ETR ETR ETR ETR ETR ETR 48" AFF ETR ETR ETR ETR SR ETR ETR ETR ETR ETR ETR ETRETRETR ETR ETRSR ETR 56" AFF 9 PM 9 12 10 11 12 SR 8 48" AFF 6 6 4 4 5 4 4 5 6 6 4 5 4 7 CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 116 PROGRAM HOUSE DR ITHACA, NEW YORK 14850 LOW RISE 7 FLOOD REMEDIATION E-102 12673546 ELECTRICAL RENOVATION PLAN M. SCHOLENO MPS 3207 JUNE 25, 2020 #E-102 KEYED RENOVATION NOTES 1 REUSE EXISTING LIGHT FIXTURE SAVED DURING DEMOLITION AND RECONNECT TO EXISTING CIRCUIT. 2 REUSE EXISTING SMOKE DETECTOR SAVED DURING DEMOLITION AND RECONNECT TO EXISTING FIRE ALARM CIRCUIT. 3 REUSE EXISTING SURFACE RACEWAY/JUNCTION BOX AND ROUTE EXISTING CIRCUIT SAVED DURING DEMOLITION THROUGH IT. 4 REUSE EXISTING PLUGMOLD SAVED DURING DEMOLITION AND CONNECT TO EXISTING CIRCUIT. 5 REUSE EXISTING VOICE/DATA OUTLETS SAVED DURING DEMOLITION AND CONNECT TO EXISTING CABLING. 6 REUSE EXISTING RECEPTACLE SAVED DURING DEMOLITION AND CONNECT TO EXISTING CIRCUIT. 7 PROVIDE NEW CEILING MOUNTED LIGHT FIXTURE AND CONNECT TO EXISTING CIRCUIT SAVED DURING DEMOLITION. MATCH EXISTING LIGHT FIXTURE. DESIGN BASIS SIMILAR TO QUORUM 3000-12165. 8 PROVIDE NEW JUNCTION BOX AND SURFACE RACEWAY BACK TO WALL MOUNTED DEVICE. ROUTE EXISTING CIRCUIT SAVED DURING DEMOLITION THROUGH NEW RACEWAY AND RECONNECT. 9 PROVIDE NEW PLUGMOLD AND CONNECT TO EXISTING CIRCUIT SAVED DURING DEMOLITION. DESIGN BASIS SIMILAR TO WIREMOLD PLUGMOLD MULTIOUTLET 2000 SERIES. MATCH EXISTING COLOR, LENGTH AND OUTLET SPACING. 10 PROVIDE NEW VOICE/DATA JACK AND CONNECT TO EXISTING COMMUNICATIONS CABLING SAVED DURING DEMOLITION. DESIGN BASIS PANDUIT MINI COM EXECUTIVE SERIES SINGLE GANG ELECTRIC IVORY BEZEL CBEEI WITH CJ688TG JACK MODULES. 11 PROVIDE NEW 20A 125V NEMA 5-20R RECEPTACLE AND CONNECT TO EXISTING CIRCUIT SAVED DURING DEMOLITION. DESIGN BASIS SIMILAR TO HUBBELL CR201. MATCH EXISTING COLOR. 12 PROVIDE NEW 20A SINGLE POLE COMMERCIAL GRADE TOGGLE LIGHT SWITCH AND CONNECT TO EXISTING CIRCUIT SAVED DURING DEMOLITION. DESIGN BASIS SIMILAR TO HUBBELL CS120. MATCH EXISTING COLOR. SCALE:1/4" = 1'-0"1 ELECTRICAL RENOVATION PLAN - 1ST FLOOR SCALE:1/4" = 1'-0"2 ELECTRICAL RENOVATION PLAN - 3RD FLOOR 1 06/15/2020 ISSUE FOR 95% REVIEW 2 06/17/2020 ISSUE FOR COORDINATED REVIEW 3 06/25/2020 ISSUE FOR CONSTRUCTION