U
PAVED PARKING
PAVED PARKING
PAVED
PARKING
PAVED
PARKING
ARKING
NPAVED
PAVED
PARKING
UNPAVED PARKING
UNPAVED PARKING
CB
C A M P U S R O A D
SOUTH AVESTEWART AVECORNE
LL U N I V
E
R
SI
TYFOUN
D E D 5681
AD CORNE LL U N IV
E
R
SI
TYFOUN
DE D 5681AD
FACILITIES
ENGINEERING
N
ARCHIVE BAR CODEITHACA, NEW YORK
ARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
Cornell University
14 SOUTH AVENUE
BALCONY AND
STAIR REPAIR
T-000
11660982A
TITLE SHEET
Q. OLSEN
JD
4724
OCTOBER 11, 2019
BALCONY AND STAIR REPAIR
T-000 TITLE SHEET
STRUCTURAL
S-001 GENERAL NOTES AND SYMBOL LEGENDS
S-101 DEMO PLAN AND EGRESS PLAN
S-102 BALCONY AND STAIRS PLAN
S-401 GUARDRAIL AND CONCRETE DETAILS
S-402 STEEL DETAILS
S-403 MOMENT CONNECTION
SITE LOCATION -14 SOUTH AVE.
KEY PLAN -SECOND FLOOR LEVEL
AREA OF WORK
BUILDING CODE SUMMARY
APPLICABLE CODES
PERFORM ALL CONSTRUCTION IN ACCORDANCE WITH THE 2017 NEW YORK
STATE UNIFORM CODE SUPPLEMENT AND CITY OF ITHACA AMENDMENTS
REFERENCING THE 2015 INTERNATIONAL BUILDING CODE (IBC) AND THE
2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC).
PROJECT SUMMARY
THIS PROJECT INCLUDES THE RENOVATION OF 455 SF OF RESIDENCES.
THE WORK IS ALTERATION LEVEL 2 DUE TO THE INSTALLATION OF NEW
STRUCTURAL ELEMENTS AND THE REPAIR OF EXISTING STRUCTURAL AND
ARCHITECTURAL ELEMENTS.
BUILDING LIMITATIONS
CONSTRUCTION CLASSIFICATION:2B
CLASSIFICATION OF HAZARDS:NONE
HIGH-RISE BUILDING:NO
EXTINGUISHING REQUIREMENT:THE EXISTING BUILDING
IS SPRINKLERED
OCCUPANCY
OCCUPANCY CLASSIFICATION:RESIDENTIAL (R2)
AREA OF WORK
DRAWING INDEX
PROJECT SCOPE
THE PURPOSE OF THIS PROJECT IS TO RE-ESTABLISH THE EXTERIOR STEEL STAIR SERVICING THE BALCONY AS MEANS OF EGRESS. STRUCTURAL
SCOPE INCLUDES DEMO STAIR TREADS AND STRINGERS, CONCRETE SLAB ON METAL DECK LANDING, AND DETERIORATED CONCRETE. INSTALL
NEW TREADS, NEW STRINGERS, SUPPORT STEEL, GRATING AT LANDING, SELECT CONCRETE REPAIR, AND SELECT RAILING REPAIR.
GENERAL SYMBOLS LEGEND
EXTERIOR ELEVATION
1
1
1 1X-100
X-100
1
1
1 1 INTERIOR ELEVATION
1
X-100
SECTION MARKER
1
X-100 ENLARGED DETAIL
#CONSTRUCTION KEYED NOTE
DEMOLITION KEYED NOTE#
DRAWING REVISION NOTE#
LINETYPE: TO BE PROVIDED / NEW
LINETYPE: DEMOLITION / TO BE RELOCATED
LINETYPE: EXISTING TO REMAIN
4724
1 10/11/19 ISSUE FOR CONSTRUCTION
GROUND SNOW LOAD, Pg 40 PSF
FLAT-ROOF SNOW LOAD, Pf 28 PSF
SNOW LOAD IMPORTANCE FACTOR, Is 1.00
THERMAL FACTOR, Ct 1.0
DRIFT SURCHARGE LOAD, Pd N/A
SNOW DRIFT WIDTH, w
ULTIMATE WIND DESIGN SPEED, Vult 115 MPH
WIND EXPOSURE CATEGORY B
RISK CATEGORY II
INTERNAL PRESSURE COEFFICIENT, GCpi +/-0.18
MWRFS DESIGN PRESSURE COEFFICIENT, qz
C&C DESIGN PRESSURE COEFFICIENT, qcc
SEISMIC IMPORTANCE FACTOR, Ie 1.00
Ss 0.15g
S1 0.06g
ASSUMED SOIL SITE CLASS D
SDS 0.160g
SD1 0.096g
SEISMIC DESIGN CATEGORY B
SEISMIC FORCE-RESISTING SYSTEM(S)
BASE SHEAR, V
SEISMIC RESPONSE COEFFICIENT, CS
RESPONSE MODIFICATION COEFFICIENT, R
ANALYSIS PROCEDURE
DESIGN PARAMETERS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
DEAD LOADS
BALCONY
LIVE LOADS
TOTAL LOADS
STAIRS LANDING
LOADS (PSF)
LOCATIONS
TOTAL DEAD LOADS
TOTAL LIVE LOADS
DESIGN LOADS TABLE
9" (AVG.) NORMAL WEIGHT CONCRETE SLAB 113
METAL GRATING 18
PUBLIC ASSEMBLY / LOBBIES 100
113
18 18
100 100 100
100 100 100
221 126 126
STEEL FRAMING 8 8 88
26 26121
MATERIAL
MIX DESIGNS
ADMIXTURES
REINFORCEMENT
CURING PRODUCTS & METHODS
STRUCTURAL STEEL:
STEEL PIECES AND ERECTION PLANS
WELDS
CAST IN PLACE CONCRETE:
POST-INSTALLED ANCHORS
REQUIRED SUBMITTALS
SCHEDULE /
SHOP DWGS
X
PRODUCT
DATA
INSPECTIONS
& TESTS
X
X
X
X
X X
X
X
X
X X
CONCRETE LOCATION F
CONCRETE DURABILITY
S W C
RAISED SLAB F3 W1 C2S0
WIDE FLANGE MEMBERS A992, Fy = 50 KSI
STRUCTURAL STEEL GRADES
HSS RECTANGULAR MEMBERS
CHANNELS AND ANGLES
A500 GRADE B, Fy = 46 KSI
A36, Fy = 36 KSI
PLATES A572, Fy = 50 KSI
THREADED RODS F1554 GRADE 36, Fy = 36 KSI S#
ONE-WAY SLAB # INCHES THICK
W#X#STEEL BEAM OF SIZE W#X#
STEEL BEAM WITH MOMENT CONNECTION
EXISTING STEEL COLUMN
EXISTING BEAM OVER STEEL COLUMN
_# (E)EXISTING STEEL BEAM
STRUCTURAL LEGEND CORNE LL U N IV
E
R
SI
TYFOUN
DE D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEITHACA, NEW YORK
ARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
14 SOUTH AVENUE
BALCONY AND
STAIR REPAIR
S-001
11660982A
GENERAL
NOTES AND
SYMBOL
LEGENDS
Q. OLSEN
JD
4724
OCTOBER 11, 2019
1. PERFORM ALL CONSTRUCTION IN ACCORDANCE WITH THE 2017 NEW YORK
STATE UNIFORM CODE SUPPLEMENT AND CITY OF ITHACA AMENDMENTS
REFERENCING THE 2015 INTERNATIONAL BUILDING CODE. THE FOLLOWING
CODES AND STANDARDS ARE REFERENCED IN THE PROJECT DOCUMENTS:
A. ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL
CONCRETE
B. AISC 360-10 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
C. ASCE7-10 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES WITH SUPPLEMENT NO. 1
D. 2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC)
2. GRAVITY LOAD DEFLECTION CRITERIA:
A. TOTAL LOAD: L/240
B. LIVE LOAD: L/360
3.CONTRACTOR SHALL REPORT TO THE STRUCTURAL ENGINEER ANY
DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS.
4. THE CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH THE
OWNER AND MEET OWNER’S REQUIREMENTS INCLUDING SCHEDULING AND
TIMING OF WORK.
5.CONTRACTOR SHALL PROVIDE ADEQUATE MEASURES TO PROTECT WORKERS
AND THE GENERAL PUBLIC OVER PROJECT DURATION.
6.BEFORE COMMENCING CONSTRUCTION, CONTRACTOR TO COORDINATE ALL
WORK, SCHEDULE, AND REQUIRED NOTIFICATIONS WITH CORNELL
DEPARTMENTS OF STUDENT AND CAMPUS LIFE (SCL) AND ENVIRONMENTAL
HEALTH AND SAFETY (EHS).
CAST IN PLACE CONCRETE
1. CLEAR COVER FOR REINFORCING STEEL SHALL BE PER THE TABLE ON THIS
SHEET WHICH CONFORMS TO ACI 318-14 TABLE 20.6.1.3.1.
2. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH REINFORCEMENT
LAYOUT FOR APPROVAL BY ENGINEER OF RECORD
3. CONTRACTOR SHALL SUBMIT ALL PRODUCT DATA FOR APPROVAL BY
ENGINEER OF RECORD.
4. STEEL REINFORCING BARS SHALL MEET THE REQUIREMENTS OF ASTM A-615
AND SHALL BE GRADE 60. STAINLESS STEEL REINFORCING BARS SHALL MEET
THE REQUIREMENTS OF ASTM A-955 AND SHALL BE ENDURAMET 32 OR
APPROVED EQUAL. WELDED WIRE FABRIC SHALL MEET THE REQUIREMENTS
OF ASTM A-1064. STAINLESS STEEL WELDED WIRE FABRIC SHALL MEET THE
REQUIREMENTS OF ASTM A-1022. ALL STAINLESS STEEL REBAR SHALL BE TIED
WITH STAINLESS STEEL WIRE OR PLASTIC ZIP TIES.
5. FOR CONCRETE EXPOSED TO MOISTURE, REPLACE 15% TO 20% OF THE
PORTLAND CEMENT WITH SUPPLEMENTARY CEMENTITIOUS MATERIALS.
6. THE DENSITY OF THE CONCRETE MIX SHALL BE 145 PCF +/-5 PCF FOR NORMAL
WEIGHT CONCRETE. NO LIGHT WEIGHT CONCRETE IS TO BE USED FOR
REPAIRS.
7. SEE TABLE THIS SHEET FOR CONCRETE DURABILITY DESIGN CLASSIFICATIONS
PER ACI 318-14 TABLE 19.3.1.1. CONCRETE MIX DESIGNS SHALL MEET THE
REQUIREMENTS OF ACI FOR THOSE CATEGORIES.
8. CONCRETE PRODUCER SHALL VERIFY THAT SUBMITTED CONCRETE MIXES DO
NOT EXCEED THE MAXIMUM WATER-SOLUBLE CHLORIDE ION LIMITS PER THE
EXPOSURE CLASS AS STATED IN ACI 318-14 TABLE 19.3.2.1.
9. CAST IN PLACE CONCRETE SHALL BE WET CURED FOR A MINIMUM OF SEVEN
DAYS. .
10. CONTRACTOR SHALL SUBMIT ALL CURING METHODS AND PRODUCT DATA FOR
APPROVAL BY ENGINEER OF RECORD.
11. THE WATER CEMENT RATIO SHALL BE MAXIMUM 0.43. THE CONTRACTOR IS
NOT PERMITTED TO ADD MORE WATER THAN IS SPECIFIED ON THE SUBMITTED
MIX DESIGNS WITHOUT APPROVAL FROM THE STRUCTURAL ENGINEER.
CONTRACTOR IS REQUIRED TO CLEARLY NOTE ON THE DELIVERY TICKET THE
QUANTITY OF WATER WITHHELD AT THE BATCHING PLANT THAT CAN BE
ADDED ONSITE.
12. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 5000
PSI.
13. NONSHRINK GROUT SHALL BE PREPACKAGED NATURAL AGGREGATE GROUT,
HIGH PRECISION, 8000 PSI MINIMUM, AND CONFORMING TO ASTM C 1107,
GRADE B.
STRUCTURAL STEEL
1. ALL STRUCTURAL STEEL SHALL BE ASTM FABRICATED AND ERECTED IN
ACCORDANCE WITH AISC "STEEL CONSTRUCTION MANUAL" AND ALL WORK
SHALL COMPLY WITH AISC "CODE OF STANDARD PRACTICE FOR STEEL
BUILDINGS AND BRIDGES."
2. GRADES OF STRUCTURAL STEEL TO BE PER TABLE THIS SHEET U.O.N.
3. ALL BOLTED CONNECTIONS TO BE MADE WITH A325 OR A490 TYPE N HIGH
STRENGTH BOLTS UNLESS GALVANIZED BOLTS ARE SPECIFIED. WHERE
GALVANIZED BOLTS ARE SPECIFIED ON THE DRAWINGS, GALVANIZED BOLTS
SHALL CONFORM TO ASTM A153, CLASS C AND SHALL BE HOT-DIP GALVANIZED.
UNLESS OTHERWISE NOTED, ALL CONNECTIONS SHALL BE DESIGNED AS
BEARING-TYPE BOLTED CONNECTIONS TIGHTENED TO THE "SNUG-TIGHT"
CONDITION.
.
4. ALL NUTS SHALL MEET REQUIREMENTS OF ASTM A-563 DH OR ASTM A-194 2H.
5. ALL WASHERS SHALL MEET REQUIREMENTS OF ASTM F-436.
6. ALL BOLT HOLES IN STEEL MEMBERS SHALL BE 1/16" LARGER IN DIAMETER
THAN THE NOMINAL SIZE OF THE BOLT USED, U.N.O. ON DRAWINGS.
7. WELDING SHALL MEET THE REQUIREMENTS OF THE "STRUCTURAL WELDING
CODE" AWS D1.1-2006. ELECTRODES SHALL HAVE A MINIMUM TENSILE
STRENGTH OF 70 KSI AND BE LOW-HYDROGEN TYPE. THE LENGTH OF WELD
SPECIFIED ON THE DRAWINGS IS THE MINIMUM EFFECTIVE LENGTH OF THE
WELD. ALL WELDS TO BE A MINIMUM 1/4" FILLET WELD U.N.O. ON DRAWINGS.
8. ALL STEEL SHALL BE HOT-DIP GALVANIZED TO ASTM A-123 GRADE 65. TOUCH-
UP ALL DAMAGED AREAS WITH ZRC GALVILITE GALVANIZING REPAIR (95%
ZINC).
9. ALL STEEL SHALL BE INSTALLED WITH CAMBER UP EXCEPT WHERE NOTED
OTHERWISE ON DRAWINGS AND AT CANTILEVERS WHERE STEEL SHALL BE
INSTALLED WITH CAMBER DOWN.
10. NO FABRICATION SHALL PROCEED PRIOR TO SHOP DRAWING APPROVAL. SHOP
DRAWINGS MARKED "REJECTED" OR "REVISE AND RESUBMIT" MAY NOT BE
FABRICATED WITHOUT ADDITIONAL CHANGES BEING MADE.
11. STRUCTURAL STEEL SHOP DRAWINGS SHALL INCLUDE DETAILS FOR
APPLICATIONS AND ASSEMBLY OF ALL STRUCTURAL MEMBERS; INCLUDE
DETAILS OF CUTS, CONNECTIONS, HOLES, AND OTHER PERTINENT DATA; AND
INDICATE WELDS BY STANDARD AWS 2.1 SYMBOLS SHOWING SIZE, LENGTH,
AND TYPE OF EACH WELD. SHOP DRAWINGS SHALL BE SUBMITTED TO
ARCHITECT FOR APPROVAL PRIOR TO FABRICATION.
12. SPLICING OF STRUCTURAL MEMBERS WHERE NOT DETAILED ON THE
CONTRACT DOCUMENTS IS PROHIBITED WITHOUT PRIOR APPROVAL OF THE
STRUCTURAL ENGINEER AS TO LOCATION, TYPE OF SPLICE, AND CONNECTION
TO BE MADE.
13. OVERSIZED OR SLOTTED HOLES SHALL NOT BE USED UNLESS SPECIFICALLY
INDICATED ON THE DRAWINGS.
POST-INSTALLED ANCHORS
1. UNLESS NOTED OTHERWISE ON DRAWINGS, ADHESIVE ANCHOR SYSTEMS
SHALL USE HILTI HIT HY200R EPOXY.
2. UNLESS NOTED OTHERWISE ON THE DRAWINGS, MECHANICAL ANCHORS SHALL
BE POWERS POWER-STUD+ SD6 1/2" DIAMETER STAINLESS STEEL ANCHORS.
TESTING & INSPECTIONS
1. OWNER SHALL RETAIN THE SERVICES OF AN INSPECTION AGENCY TO PERFORM
INSPECTIONS ON THE FOLLOWING ITEMS:
A. FIELD WELDS
B. STRUCTURAL STEEL INSTALLED, INCLUDING CONNECTIONS AND
PLACEMENT
C. POST-INSTALLED ANCHORS
D. CONCRETE REINFORCEMENT, INCLUDING PLACEMENT
2. ADDITIONAL INSPECTIONS SHALL BE PROVIDED IN ACCORDANCE WITH LOCAL
CODE REQUIREMENTS.
STRUCTURAL GENERAL NOTESSTRUCTURAL GENERAL NOTES (CONT.)
1 10/11/19 ISSUE FOR CONSTRUCTION
1
2 3
4' - 1 1/2" V.I.F.4' - 6 1/2" V.I.F.1' - 0"±7' - 0" ±EXISTING BUILDING
36' - 0" V.I.F.
EXISTING CONCRETE
SLAB ON METAL DECK
WITH DECK EDGE ANGLE
EXISTING STEEL PAN STAIRS
WITH CONCRETE FILL 3' - 8" V.I.F.EXISTING FRAMED CONCRETE SLAB -
12" AT BUILDING FACE TAPERED
DOWN TO 6" AT EDGE OF BALCONY 10' - 0" V.I.F.STAIR DOWN
EXISTING 42" GUARDRAIL
EXISTING 42" GUARDRAIL
EXISTING 42" GUARDRAIL
EXISTING 42" GUARDRAIL
45
EXISTING CONCRETE BALCONY
W/ EXISTING COATING
DEMO EXISTING STAIR
STRINGERS. DO NOT
DISCARD EXISTING
RAILING. CONFIRM
EXTENTS OF STEEL DEMO
WITH ENGINEER PRIOR TO
CONSTRUCTION
PRIOR TO DEMO OF STAIRS AND LANDING
SLAB, SHORE THE STRUCTURAL FRAMING AT
THIS CORNER OF THE LANDING.
EXISTING CONCRETE BALCONY
W/ EXISTING COATING
EXISTING BUILDING
EXISTING FRAMED CONCRETE SLAB -
12" AT BUILDING FACE TAPERED
DOWN TO 6" AT EDGE OF BALCONYSTAIR DOWN
P A T H O F E G R E S S -B A L C O N Y
EXISTING 42" GUARDRAIL
EXISTING 42"
GUARDRAIL
EXISTING 42" GUARDRAIL
EXISTING 42" GUARDRAIL
5 7 '-0 "PATH OF EGRESS -BALCONY34'-0"P A T H O F E G R E S S -R O O M 3 1 3
3 5 '-0 "P A T H O F E G R E S S -B A L C O N Y47'-0 "
P
A
T
H O
F E
G
R
E
S
S -
R
O
O
M 313
35'-0"
EXISTING DOORS EXISTING DOORS CORNE LL U N IV
E
R
SI
TYFOUN
DE D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEITHACA, NEW YORK
ARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
14 SOUTH AVENUE
BALCONY AND
STAIR REPAIR
S-101
11660982A
DEMO PLAN
AND EGRESS
PLAN
Q. OLSEN
JD
4724
OCTOBER 11, 2019
SCALE:1/2" = 1'-0"1 DEMO PLAN
S-101 KEYED DEMOLITION NOTES
1 REMOVE ALL UNSOUND CONCRETE IN SPECIFIED AREA AND OTHER AREAS
TO BE DETERMINED IN COORDINATION WITH ENGINEER.
2 REMOVE AND DISPOSE OF THE CONCRETE SLAB ON METAL DECK LANDING.
STEEL FRAMING TO REMAIN.
3 REMOVE AND DISPOSE OF EXISTING STAIR TREADS, INCLUDING CONCRETE,
COATING AND METAL PAN. REMOVE AND DISPOSE OF EXISTING STEEL STRINGERS.
GUARDS AND HANDRAILS TO BE REMOVED AND REINSTALLED AFTER
CONSTRUCTION OF NEW STAIR. DO NOT DISPOSE OF EXISTING GUARDRAIL AND
HANDRAIL.
4 REMOVE EXISTING GUARDRAIL BEFORE BEGINNING CONCRETE DEMO. DO NOT
DISPOSE OF EXISTING GUARDRAIL. SEE S-102 FOR GUARDRAIL REPAIRS.
5 REMOVE EXISTING GUARDRAIL. DO NOT DISPOSE OF EXISTING GUARDRAIL. SEE
S-102 FOR GUARDRAIL REPAIRS. SEE S-401 FOR NEW CONNECTION DETAIL.
#
SCALE:1/2" = 1'-0"2 EGRESS PLAN
N
1 10/11/19 ISSUE FOR CONSTRUCTION
W12(E)
W12(E)
W12(E)
W12(E)W12(E)W12(E)W12(E)W12(E)C12X20.7
EXISTING CONCRETE SLAB
12" THICK AT BUILDING FACE
TAPERED TO 6" THICK AT EDGE
OF BALCONY
1' - 0"±7' - 0"±W12(E)STAIR DOWN
43219' - 5"14' - 11 1/2"10' - 5 1/2"1' - 0"8' - 4"8"EXISTING BUILDING
W12(E)
C12(E)
TOP OF CONCRETE
(0'-0")C12(E)W12X26 W12X26 W12X26
C12X20.7
SEE NOTE 2,
3'-10"
SEE NOTE 2, 3'-2"
SEE NOTE 2,
2'-0"MC12X10.6NEW GRATING,
EL. 0'-0"
0" 0" 0"C10X15.3C4X4.5C4X4.5
C4X4.5
AREA OF CONCRETE
REPAIRS
A
B
SEE NOTE 8
SEE S-403
4' - 1 3/8" V.I.F.4' - 6 5/8" V.I.F.BETWEEN CHANNELS3' - 8" CLEARV = 7 K
M = 25 K-FT, V = 8 K
NEW GRATING TREADS. SEE DETAIL 7/S402
(E) HSS6X6 COLUMN
BELOW, TYP.
8
S-402
6
S-402
6
S-402
2
S-402
SEE 3/S-402 FOR CONNECTION, TYP. 6 LOCATIONS
SIM.
2
S-402
OPP.
V = 7 K V = 7 K V = 7 K V = 7 K V = 7 K
4' - 2"4' - 2"OPP.
EXISTING CONCRETE SLAB
STAIR DOWN
43219' - 5"14' - 11 1/2"10' - 5 1/2"1' - 0"8' - 4"8"EXISTING BUILDING
TOP OF CONCRETE
(0'-0")
SEE 2/S-401 FOR NEW DETAIL
AT GUARDRAIL CORNER
SEE 2/S-401 FOR NEW DETAIL
AT GUARDRAIL CORNER
REMOVE GUARDRAIL ON EAST SIDE OF
BALCONY BEFORE CONCRETE REPAIRS.
AFTER CONCRETE REPAIRS ARE
COMPLETE, REATTACH SO THAT TOP OF
GUARDRAIL IS A MINIMUM OF 42" ABOVE
THE TOP OF CONCRETE. REINSTALL PER
DETAILS ON S-401.
TOP OF GUARDRAIL IS 41-1/2"
ABOVE CONCRETE. DETACH
AND REINSTALL PER DETAILS
ON S-401 SO THAT TOP OF
GUARDRAIL IS A MINIMUM OF
42" ABOVE TOP OF SLAB.
A
B
DETACH GUARDRAIL / HANDRAIL FROM
EXISTING STAIR STRINGERS AND
REINSTALL ON NEW STAIR
STRINGERS. PROVIDE NEW
GALVANIZED BOLTS WITH SAME
DIAMETER AS EXISTING BOLTS (V.I.F.)
FOR NEW CONNECTIONS. MINIMUM 3
BOLTS PER CONNECTION AND
MAXIMUM 4.CORNE LL U N IV
E
R
SI
TYFOUN
DE D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEITHACA, NEW YORK
ARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
14 SOUTH AVENUE
BALCONY AND
STAIR REPAIR
S-102
11660982A
BALCONY AND
STAIRS PLAN
Q. OLSEN
JD
4724
OCTOBER 11, 2019
SCALE:1/2" = 1'-0"1 BALCONY FRAMING PLAN
SCALE:1/2" = 1'-0"2 HANDRAIL AND GUARDRAIL PLAN
GENERAL NOTES
1. PROVIDE ONE 1" DIAMETER WEEP HOLE 2" ABOVE BASE OF EACH OF THE
EXISTING STEEL COLUMNS (TYP. 8 LOCATIONS).
2. SEE 1/S-402 FOR REINFORCEMENT AT BASE OF COLUMN.
3. ELEVATIONS NOTED ON PLAN AS (X'-X"). TOP OF CONCRETE SLAB IS ELEVATION
(0'-0"). FOR PLACEMENT OF NEW CHANNELS AT LANDING, SEE SECTIONS. NEW
W12 BEAMS TO BE PLACED PER 4/S-402. FOR PLACEMENT OF NEW MC12X10.6
BACKSPAN, SEE S-403.
4. CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD.
5. ALL REACTIONS NOTED ON PLAN ARE LRFD.
6. NEW GRATING TO MEET THE FOLLOWING REQUIREMENTS:
A. OHIO GRATING GRATER ACCESS SERRATED STEEL GRATING WITH 11
SPACING OR 7 SPACING
B. GRATING TO HAVE CORROSION PROTECTION FOLLOWING THE
MANUFACTURER'S RECOMMENDATIONS
C. MAXIMUM TREAD WEIGHT WITH HARDWARE AND CARRIER PLATES IS 18
PSF
D. TREAD WIDTH TO BE 44 INCHES
E. TREAD DEPTH MINIMUM OF 11 INCHES
F. MANUFACTURER TO FABRICATE TREADS WITH CARRIER PLATES AND
CHECKER PLATE NOSING PER MANUFACTURER'S RECOMMENDATIONS
G. TREADS MUST SUPPORT LIVE LOAD OF 100 PSF
H. IF MANUFACTURER DOES NOT PROVIDE HARDWARE FOR
ATTACHMENTS, CONTRACTOR TO PROVIDE HARDWARE PER
MANUFACTURER'S RECOMMENDATIONS AND/OR SPECIFICATIONS.
HARDWARE IS PREFERABLY STAINLESS STEEL. STEEL WITH CORROSION
PROTECTION IS ALSO AN OPTION
I. PROVIDE KICK PLATE TO LIMIT OPENING BETWEEN TREADS PER CODE
REQUIREMENTS.
7. NEW CHANNELS AT LANDING HAVE 1 KIP (LRFD) REACTIONS.
8. PROVIDE DOUBLE CLIP ANGLE SHEAR CONNECTION PER S-403.
9. CONTRACTOR RESPONSIBLE FOR LAYING OUT STAIR TREADS TO BE EQUALLY
SPACED AND MEET CODE REQUIREMENTS. RISE IS A MINIMUM OF 4" AND A
MAXIMUM OF 7".
10. REINSTALL NEW STRINGERS AT SAME LOCATION AS EXISTING STRINGERS. SEE
5/S402 FOR BASE PLATE DETAIL. AFTER DEMO OF EXISTING STAIRS, VERIFY
LOCATION OF EXISTING CONNECTION BETWEEN STRINGERS AND LANDING.
ENGINEER TO THEN DESIGN CONNECTION TO REUSE EXISTING BOLT HOLES AT
LANDING. CONNECTION WILL BE SIMILAR TO SHEAR CONNECTION AT NEW W12
BEAMS ADJACENT TO EXISTING BUILDING.
N
1 10/11/19 ISSUE FOR CONSTRUCTION
1. OUTLINE WITH MARKING PAINT THE EXACT EXTENT OF CONCRETE AREAS TO BE
REPAIRED IN COORDINATION WITH A REPRESENTATIVE OF THE ENGINEER. SOUND THE
CONCRETE WITH A HAMMER TO DETERMINE THE EXTENT OF LOOSE OR DELAMINATED
CONCRETE.
2. USING A MINIMUM NUMBER OF STRAIGHT LINES, LAYOUT AND MARK THE SAW-CUT
LOCATIONS AROUND THE REPAIR AREA. SAW-CUT 1" DEEP AROUND REPAIR AREA AT
SLIGHT BEVEL IN ORDER TO KEY THE REPAIR AREA INTO THE EXISTING CONCRETE.
3. REMOVE ALL UNSOUND CONCRETE, AGGREGATES, CEMENT PASTE, DIRT, OIL,
GREASE, FUNGUS, MILDEW, PAINT, PREVIOUS COATINGS, FORM RELEASE, CURING
AGENTS AND OTHER FOREIGN MATERIALS.
4.AT ALL REINFORCING BARS EXPOSED FOR MORE THAN HALF OF THEIR
CIRCUMFERENCE, CHIP OUT THE CONCRETE TO CREATE A 3/4" MINIMUM SPACE
BEHIND THE BAR.
5. REVIEW EACH REPAIR AREA WITH OWNERS REPRESENTATIVE. TALLY QUANTITIES
TO THE NEAREST 0.1 SQUARE FOOT.
6. SAND BLAST EXPOSED REINFORCING BARS TO COMPLY WITH SSPC-SP 6/NACE No. 3,
"COMMERCIAL BLAST CLEANING." IF THE REINFORCING BAR HAS LOST MORE THAN
25% OF ITS CROSS SECTIONAL AREA (REFER TO THE FOLLOWING TABLE), THE
REINFORCEMENT SHALL BE CUT AT THE EXTENTS OF THE SECTION LOSS, REMOVED
FROM THE STRUCTURE AND A MATCHING BAR SHALL BE INSTALLED USING LENTON
LOCK B-SERIES MECHANICAL REBAR SPLICES AT EACH END. THE ERICO LENTON LOCK
COUPLERS SHALL BE INSTALLED ACCORDING TO MANUFACTURER INSTRUCTIONS.
A. STEEL REINFORCEMENT SECTION LOSS TABLE
7.USE MECHANICAL MEANS TO REMOVE LOOSE AND DELAMINATED CONCRETE
AND ACHIEVE SURFACE PROFILE AS REQUIRED BY REPAIR MORTAR. AFTER
CONCRETE REMOVAL UTILIZE LOW PRESSURE WATER CLEANING USING
PRESSURES LESS THAN 5000 PSI.
8. WET THE CONCRETE SUBSTRATE WITH CLEAN WATER FOR 24 HOURS TO
ACHIEVE A SATURATED SURFACE DRIED CONDITION WITH NO STANDING WATER.
9.APPLY SIKACRETE 211 REPAIR MORTAR EXTENDED WITH 3/8" LIMESTONE
AGGREGATE (42 LB/UNIT). THE AGGREGATE MUST BE NON-REACTIVE
(REFERENCE ASTMC1260, C227 AND C289), CLEAN, WELL-GRADED,
SATURATED SURFACE DRY, HAVE LOW ABSORPTION, HIGH DENSITY AND
COMPLY WITH ASTM C33 SIZE NUMBER 8 PER TABLE 2. THE REPAIR MORTAR
MUST BE MIXED, INSTALLED, FINISHED AND CURED ACCORDING TO THE
MANUFACTURERS RECOMMENDATIONS.
A. NOTE: IF THE PATCH AREA IS LESS THAN 1" IN DEPTH, THE REPAIR
MORTAR DOES NOT REQUIRE 3/8" AGGREGATE. PREP AND INSTALL PER
MANUFACTURER SPECS.
B. SCOPE OF CONCRETE REPAIRS TO BE ESTIMATED AS NOTED BELOW. PROVIDE
ADD/DEDUCT UNIT PRICE IN BID FOR ITEMS 9.2.a THRU 9.2.f.
a. FULL DEPTH SLAB REPAIRS: 14 SQ FT
b. PARTIAL DEPTH SLAB REPAIRS: 6 SQ FT
c. INSTALLED #8 GR 60 DEFORMED BARS: 20 LIN FT
d. INSTALLED #5 GR 60 DEFORMED BARS: 20 LIN FT
e. LENTON REBAR COUPLERS FOR # 8 BARS: 4
f. LENTON REBAR COUPLERS FOR # 5 BARS: 4
10. PERFORM 7 DAY WET CURE OF PATCHED AREAS.
COORDINATE WITH ENGINEER
CONCRETE REPAIR CONSTRUCTION NOTES:
14 GA. 2"x2" S.S. REINF.
MESH ANCHORED TO
EXISTING CONCRETE W/
S.S. ANCHORS AT 12" O.C.
AT FULL DEPTH EDGE
REPAIRS ONLY
FORM AND PATCH
CONCRETE NOSING
END OF EXISTING SLAB
REPAIR MORTAR
TYPICAL REPAIR WHERE NOT MORE
THAN HALF THE PERIMETER OF THE
REINFORCING BAR IS EXPOSED
SAWCUT (UNDERCUT) PATCH
PERIMETER 1/2" DEEP (TYP.)
APPROXIMATE EXTENT OF REMOVAL
AND PATCHING INDICATED BY HATCH
COAT EXISTING REINFORCING AND
CONCRETE WITH BONDING AGENT
EXISTING SPALL OR DELAMINATION
PROFILE
ORIGINAL CONCRETE SURFACE
EXISTING CONCRETE SLAB
APPROXIMATE
REMOVAL LIMITS
3/4" CLEAN AROUND
EXISTING REINFORCING
(TYP.)
SAWCUT (TYP.)
BAR
SIZE
NOMINAL BAR
DIAMETER (INCHES)
LIMIT OF REDUCED BAR
DIAMETER (INCHES)
9
8
7
6
5
4
3 0.375
0.5
0.625
0.75
0.875
1
1.125
0.32
0.43
0.54
0.65
0.75
0.87
0.97
EXISTING CONNECTION DEMO
NEW CONNECTION
CUT PLATE OFF EACH
SIDE OF CONNECTION
AND DISPOSE OF BOLTS
NEW CONNECTION
NOTES:
1. CUT PLATE OFF CONNECTION SLEEVE AFTER GUARDRAIL IS REMOVED FROM BALCONY. DISPOSE OF
PLATE AND BOLTS.
2. WELD A NEW 1/2" STEEL PLATE TO THE BACK OF THE CONNECTION SLEEVE. WELD WITH MINIMUM 3" LONG
1/4" FILLET WELDS EACH SIDE OF SLEEVE. NEW PLATE TO BE 6" X 6". TOP OF PLATE TO BE INSTALLED TO
MATCH TOP OF CONCRETE. GUARDRAIL HEIGHT ABOVE TOP OF PLATE TO BE MINIMUM 42 INCHES. PLATE
TO BE HOT-DIP GALVANIZED. AFTER WELDING, TOUCH UP GALVANIZING PER THE REQUIREMENTS IN THE
STRUCTURAL GENERAL NOTES ON S-001.
3. PROVIDE (2) NEW 1/2" DIAMETER POWERS EXPANSION ANCHORS EMBEDDED 3-3/4" MINIMUM INTO THE
EXISTING CONCRETE. THE ANCHORS ARE TO BE INSTALLED 3" MINIMUM FROM THE EDGE OF THE
CONCRETE. THE ANCHORS ARE TO BE INSTALLED WITH A MINIMUM HORIZONTAL SPACING OF 4".
4. REPAIR CONCRETE FLUSH AS REQUIRED AFTER RAILING IS REMOVED.
1"4"1"
3 3/4" MIN.3"PLAN ELEVATION
NEW 1-1/2" ELBOW PIPE WELDED TO
GUARDRAIL POSTS AT EACH END OF PIPE
WITH 3/16" FILLET WELD, ALL AROUND,
TYP. 3 LOCATIONS. ELBOW DIAMETER TO
MATCH SIZE AND LOCATION OF EXISTING
HORIZONTAL PIPES
V.I.F.
EXISTING CONCRETE SLAB
CONTINUATION OF
RAIL BEYOND NOT
SHOWN FOR CLARITY
NEW 3/4" PIPE OR BAR WELDED AT
CENTER OF ELBOWS WITH 3/16"
FILLET WELD ALL AROUND AT EACH
END.
NEW 2" X 1/4" PLATE SET
TIGHT TO THE UNDERSIDE
OF THE LOWEST
HORIZONTAL PIPE AND
WELDED TO EACH POST
WITH 3/16" FILLET WELDS
ON ONE SIDE OF PLATE.
PLATE TO BE AN ELBOW
TO MATCH PIPES 2"SECTIONELEVATION
EXISTING CONCRETE SLAB
STITCH WELD 2"X1/4" PLATE
TO UNDERSIDE OF LOWEST
HORIZONTAL PIPE WITH
3/16" FILLET WELDS 2" LONG
@ 12" O.C. ON ONE SIDE OF
THE PLATE
SET TOP OF RAILING AT 43" +/-1/2"
ABOVE THE TOP OF THE CONCRETE.
TOP OF RAILING MUST BE A MINIMUM
OF 42" ABOVE TOP OF CONCRETE AT
ALL POINTS ALONG RAILING CORNE LL U N IV
E
R
SI
TYFOUN
DE D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEITHACA, NEW YORK
ARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
14 SOUTH AVENUE
BALCONY AND
STAIR REPAIR
S-401
11660982A
GUARDRAIL
AND
CONCRETE
DETAILS
Q. OLSEN
JD
4724
OCTOBER 11, 2019
SCALE:1" = 1'-0"1 CONCRETE SLAB REPAIR
SCALE:1 1/2" = 1'-0"3 GUARDRAIL CONNECTION
1 10/11/19 ISSUE FOR CONSTRUCTION
SCALE:1" = 1'-0"2 NEW GUARDRAIL CORNER
SCALE:1" = 1'-0"4 NEW PLATE AT RAILING BASE
(E) 6X6 TUBE COLUMN
NOTE 1
NOTES:
1. PROVIDE NEW HOT-DIP GALVANIZED L4X4X1/2 ANGLE AT SPLIT
CORNER (SEE PLAN FOR LOCATIONS AND LENGTHS). WELD
ALONG FULL LENGTH OF ANGLE WITH 5/16" FILLET WELD, BOTH
LEGS.
PROVIDE WEEP
HOLE ON THIS FACE
OF COLUMN
PROVIDE 5/16" FILLET
WELD ALONG FULL
LENGTH OF ANGLE,
BOTH SIDES
NOTES:
1. PROVIDE (2) 6" LONG L4X4X5/16 ANGLES FOR CONNECTION. DRILL NEW BOLT HOLES IN
EXISTING BEAM WHERE NEEDED. TOUCH UP GALVANIZATION PER STRUCTURAL STEEL
GENERAL NOTES. REUSE EXISTING HOLES IN EXISTING BEAMS IF POSSIBLE. VERIFY
PLACEMENT OF BOLT HOLES IN FIELD AND HAVE FACILITIES ENGINEERING REVIEW
ALTERATIONS TO CONNECTIONS.
2. PROVIDE A TOTAL OF (4) BOLTS AT EXISTING BEAM AND (2) BOLTS AT NEW BEAM. BOLTS TO BE
3/4" DIAMETER A325N.
3. THIS CONNECTION IS APPLICABLE TO ALL NEW CONNECTIONS ON GRIDLINE "A".
4. SETBACK BETWEEN NEW AND EXISTING BEAMS IS TO BE 1/2".3"3 1/2"1"1 1/4"NEW BEAM DETAILING
3"
1 1/2"
NEW CONNECTION
MINIMUM 1" DRYPACK
BETWEEN TOP OF
STEEL AND UNDERSIDE
OF SLAB
NEW STEEL BEAM, TOP OF
STEEL MINIMUM 1" BELOW
UNDERSIDE OF EXISTING
CONCRETE SLAB
1 1/2"
NOTES:
1. PROVIDE 3/4" DIAMETER HOLE IN TOP FLANGE OF NEW STEEL BEAM. HOLE TO BE
DRILLED IN SHOP AND CORROSION PROTECTION OF BEAM TO BE TOUCHED UP
AFTER. PROVIDE 1/2" DIAMETER THREADED ROD EMBEDDED 3" WITH HILTI HIT HY
200R EPOXY. THREADED RODS LOCATED ALONG TOP FLANGE OF BEAM AT 3'-0"
O.C.
NOTE 1
EXISTING
CONCRETE
SLAB
C4X5.4
(E) 12" CHANNEL
AT LANDING
GRATING, SEE PLAN FOR
BALANCE OF INFORMATION
NOTES:
1. DO NOT SHIM BETWEEN NEW AND EXISTING CHANNELS.
ALIGN, TYP.7" MAX.NOTES:
1. SEE PLAN FOR GRATING, NOSING, AND CARRIER PLATE
INFORMATION.
2. IF MANUFACTURER DOES NOT PROVIDE BOLTS, PROVIDE BOLTS
MEETING THEIR SPECIFICATIONS. BOLTS PREFERABLY TO BE
STAINLESS STEEL OR HAVING ANOTHER TYPE OF CORROSION
PROTECTION. PROVIDE WASHERS IF NOT PROVIDED BY
MANUFACTURER. WASHERS TO BE STAINLESS STEEL.
3. SET TREAD PLACEMENT SUCH THAT TREADS ARE EQUALLY
SPACED AND THE RISE BETWEEN TREADS IS 7" MAXIMUM AND 4"
MINIMUM. LOWER TREAD TO EXTEND PAST UPPER NOSING BY 1"
(TYP.).
MIN. 11"
1"
8 1/2"
MIN. 1/4" FILLET
WELD, BOTH SIDES
OF CHANNEL
NOTE 1
NOTES:
1. PROVIDE (1) 4" X 1'-0" X 1/2" PLATE WELDED TO THE BOTTOM OF THE CHANNEL SO THAT
THE 4" DIMENSION IS PARALLEL TO THE CHANNEL. PROVIDE (4) 1/2" DIAMETER A325N
BOLTS. PLATE TO HAVE (4) OVERSIZED HOLES 1" FROM EDGE OF PLATE IN BOTH
DIRECTIONS. DRILL NEW HOLES IN EXISTING WIDE FLANGE BEAM THAT ARE 1" FROM
EDGE OF FLANGE AND ARE OVERSIZED HOLES FOR THE 1/2" DIAMETER BOLTS. TOUCH
UP GALVANIZATION OF EXISTING BEAM. PROVIDE SHIMS AS NEEDED WITH SAME
DIMENSIONS AND BOLT HOLES AS PLATE WELDED TO CHANNEL. SHIMS SHOWN HERE
SCHEMATICALLY.
2. AT CONNECTION BETWEEN NEW CHANNELS, PROVIDE 1/4" THICK PLATE WELDED TO
C10 CHANNEL WITH 3/16" FILLET WELD ON THREE SIDES. PLATE DIMENSIONS SHOWN
ABOVE. NEW BOLTS TO BE (2) 5/8" DIAMETER A325N BOLTS. HOLES TO BE STANDARD
SIZE BOLT HOLES. TOP COPE TO BE 2-1/2" LONG X 1" DEEP. BOTTOM FLANGE TO BE CUT
AT END OF BEAM. CUT IS 2" LONG.
3. ALL NEW BOLTS TO BE EITHER STAINLESS OR HOT-DIP GALVANIZED. ALL NEW PLATES
TO BE HOT-DIP GALVANIZED.
NOTE 2
1 1/2"1 3/4"1"1 1/4"1"GRATING, SEE PLAN FOR
BALANCE OF INFORMATION
1 3/4"2"
1/2"2"2 1/2"2 1/4"
NEW C4X4.5
(E) 12" CHANNEL
AT LANDING
GRATING, SEE PLAN FOR
BALANCE OF INFORMATION
CONTINUOUS SHIMS, SEE NOTE 1
NOTES:
1. GRATING TO BE PLACED SUCH THAT TOP OF GRATING ELEVATION
MATCHES TOP OF CONCRETE ELEVATION. PROVIDE HOT-DIP
GALVANIZED CONTINUOUS STEEL PLATE SHIMS BETWEEN
BOTTOM OF NEW C4X4.5 AND TOP OF EXISTING 12" CHANNEL.
WELD SHIM TO UNDERSIDE OF NEW CHANNEL AND TO TOP OF
EXISTING CHANNEL.
2. TYPICAL CONNECTION BETWEEN NEW C4 CHANNELS SHOWN
HERE. PROVIDE 5" X 2" X 1/4" PLATE WELDED TO CHANNEL WITH
MINIMUM 1" LONG 3/16" FILLET WELD ON BOTH SIDES. NEW BOLTS
TO BE (2) 5/8" DIAMETER A325N BOLTS. HOLES TO BE STANDARD
SIZE BOLT HOLES. SETBACK BETWEEN CHANNELS IS 1/2". TOP
AND BOTTOM COPES SHOWN ARE TO BE 1-1/2" LONG X 3/4" DEEP.
BOLTS TO BE EITHER STAINLESS OR HOT-DIP GALVANIZED. PLATE
TO BE HOT-DIP GALVANIZED.
3/16" FILLET WELD,
BOTH SIDES
1 1/4"
1 3/4"
1 1/2"
1/2"1"1"WELD SHIMS
WELD SHIMS
NEW CONNECTION,
SEE NOTE 2
NOTES:
1. TREADS NOT SHOWN FOR CLARITY
2. CONCRETE PAD DIMENSIONS TO BE VERIFIED IN THE FIELD.
3. LOCATION OF STRINGER BASE ON PAD TO BE VERIFIED IN FIELD.
4. PROVIDE TWO (2) MECHANICAL ANCHORS EMBEDDED INTO THE
CONCRETE AT EACH BASE PLATE.
5. INSTALL ANCHORS ON THE INSIDE FACE OF THE STRINGER AND
CLOSE TO ONE END OF THE BASE PLATE. THE FIRST TREAD TO BE
PLACED SUCH THAT ANCHORS TO NOT POSE A TRIPPING HAZARD.1"1"8"11"1"3 1/2"2"1"
BASE PLATE PLANELEVATION CORNE LL U N IV
E
R
SI
TYFOUN
DE D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEITHACA, NEW YORK
ARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
14 SOUTH AVENUE
BALCONY AND
STAIR REPAIR
S-402
11660982A
STEEL DETAILS
Q. OLSEN
QCO
4724
OCTOBER 11, 2019
SCALE:1 1/2" = 1'-0"1 COLUMN REINFORCEMENT
SCALE:1" = 1'-0"3 NEW TO EXISTING STEEL BEAM CONNECTION
SCALE:1 1/2" = 1'-0"4 DRYPACKED BEAM DETAIL
SCALE:1 1/2" = 1'-0"6 SECTION
SCALE:1" = 1'-0"7 NEW STAIR TREADS
SCALE:3" = 1'-0"2 SECTION
1 10/11/19 ISSUE FOR CONSTRUCTION
SCALE:3" = 1'-0"8 SECTION
SCALE:1" = 1'-0"5 NEW STRINGER BASE PLATES
A
A
SECTION A-A
NOTES:
1. AT SHEAR CONNECTION, PROVIDE A TOTAL OF (4) 6" LONG L4X4X1/4 ANGLES AND (8) 3/4" DIAMETER A325N BOLTS. AT
EXISTING CHANNEL AND EXISTING WIDE FLANGE, DRILL HOLES FOR NEW CONNECTION IF NEEDED. WHERE ANY NEW
HOLES ARE DRILLED, TOUCH UP GALVANIZING PER THE STRUCTURAL STEEL SECTION OF THE GENERAL NOTES ON
S-001.
2. PROVIDE TWO NEW STEEL PLATES FOR THE MOMENT CONNECTION. PLATES TO BE 1/2" X 4" X 12". REMOVE DRYPACK
ABOVE EXISTING BEAMS AT THE LOCATION OF THE MOMENT CONNECTION SO THAT NEW PLATE CAN BE INSTALLED
ABOVE THE BEAM. TOP PLATE TO BE WELDED TO CHANNEL FROM UNDERSIDE OF PLATE. WELD TO BE MINIMUM 1/4"
FILLET WELD THAT IS 3" LONG ON EACH SIDE OF EACH CHANNEL. BOTTOM PLATE TO HAVE SAME WELD SIZE AND
LENGTH REQUIREMENTS.
3. NEW STEEL BEAM IS COPED AT THE TOP AND BOTTOM. THE TOP COPE IS 3/4" DEEP AND 1-3/4" LONG. THE SETBACK
BETWEEN THE NEW STEEL BEAM AND THE EXISTING STEEL BEAM IS 1/2".
4. NEW BOLTS, ANGLES, AND PLATES TO BE EITHER HOT-DIP GALVANIZED OR STAINLESS STEEL.
1 1/2"
1 1/2"
GRATING AND STEEL
BEAM, SEE PLAN FOR
BALANCE OF
INFORMATION NOT
SHOWN HERE
EXISTING CONCRETE SLAB
DRYPACK
EXISTING STEEL BEAM
EXISTING STEEL BEAM4 1/2"1 1/2"3"1 1/2"PROVIDE
MINIMUM 3"
LONG 1/4" FILLET
WELD BETWEEN
PLATE AND
CHANNEL, 2
LOCATIONS
NEW MC12
NEW MC12PROVIDE
MINIMUM 3"
LONG 1/4" FILLET
WELD BETWEEN
PLATE AND
CHANNEL, 2
LOCATIONS
(2) 6" LONG L4X4X1/4 ANGLES ON THIS SIDE OF
CONNECTION AND (2) ON THE OTHER SIDE OF
THE EXISTING WIDE FLANGE BEAM SO THAT
EACH CHANNEL IS CONNECTED TO TWO
ANGLES WHICH ARE THEN ATTACHED TO THE
WIDE FLANGE BEAM
(4) 3/4" DIAMETER A325 BOLTS GO THROUGH THE
WIDE FLANGE, (2) BOLTS GO THROUGH THE EXISTING
CHANNEL, AND (2) GO THROUGH THE NEW CHANNEL
FOR A TOTAL OF (8) BOLTS. ONLY THE BOLTS
THROUGH THE WIDE FLANGE ARE SHOWN IN THIS
SECTION. THE OTHER PART OF THIS DETAIL SHOWS
THE BOLTS GOING THROUGH THE CHANNELS. THE
ANGLES HAVE TWO BOLTS THROUGH EACH LEG BUT
THE LEGS OF THE ANGLES CONNECTED TO THE
WIDE FLANGE ARE ATTACHED WITH THE SAME
BOLTS PASSING THROUGH AN ANGLE LEG, THE WIDE
FLANGE, AND ANOTHER ANGLE LEG.
PROVIDE (2) NEW STEEL PLATES 1/2" X 4" X 12", ONE AT
THE TOP OF THE CHANNELS AND ONE AT THE BOTTOM
REMOVE DRYPACK WHERE ONE PLATE WILL BE LOCATED AND
INSTALL PLATE OVER THE TOP OF THE WIDE FLANGE BEAM
1/2"3/4"1 3/4"3/4"1 3/4"CORNE LL U N IV
E
R
SI
TYFOUN
DE D 5681AD
FACILITIES
ENGINEERING
ARCHIVE BAR CODEITHACA, NEW YORK
ARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
DATE:
FACILITY:
DESIGN:
DRAWN:
WWW.FCS.CORNELL.EDU
IT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT THEIR SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR
SIGNATURE, THE DATE OF SUCH ALTERATION, AND
A SPECIFIC DESCRIPTION OF THE ALTERATION.
WARNING
REVISIONS
ARCHITECTURAL, STRUCTURAL,
CIVIL, ENVIRONMENTAL,
MECHANICAL, AND ELECTRICAL
ENGINEERING
201 HUMPHREYS SERVICE BLDG
ITHACA, NEW YORK 14853-3701
14 SOUTH AVENUE
BALCONY AND
STAIR REPAIR
S-403
11660982A
MOMENT
CONNECTION
Q. OLSEN
QCO
4724
OCTOBER 11, 2019
0 1 3 6
SCALE: 3"=1'-0"
1 10/11/19 ISSUE FOR CONSTRUCTION