HomeMy WebLinkAboutBaker RFD Kitchen Renovation 100% CD_S&SCB FP UPDNUPBAKER TOWER3004TBAKER SOUTH 3004SFOUNDERS HALL 3005BAKER NORTH 3004NBOLDT HALL 3006 WEST AVEUNIVERSITY AVE ALICE COOK HOUSE 3031 CARL BECKER HOUSE 3032 STEWART AVEAREA OF WORK FLORA ROSE HOUSE 3035 MENNEN HALL 3014LYON HALL 3011 AREA OF WORK T-001 TITLE SHEET ARCHITECTURAL A-001 GENERAL NOTES, SYMBOLOGY, AND ABBREVIATIONS A-101 DEMOLITION PLAN - GROUND FLOOR & RENOVATION PLAN - BASEMENT A-102 RENOVATION PLANS, ELEVATIONS AND SECTION MECHANICAL/PLUMBING MP-001 GENERAL NOTES AND SYMBOL LEGENDS MP-101 GROUND FLOOR MECHANICAL & PLUMBING DEMOLITION & INSTALLATION PLANS MP-501 SCHEDULES ELECTRICAL E-001 ELECTRICAL NOTES, SYMBOL, LEGEND, & ABBREVIATIONS E-101 PARTIAL GROUND FLOOR ELECTRICAL REMOVAL AND PLANCORNE LL U N I V E R SI TYFOUN D E D 5681 AD CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 Cornell University BAKER SOUTH BAKER SOUTH RFD KITCHEN RENOVATION T-001 12309492 TITLE SHEET FE DESIGN JGC 3004S APRIL 15, 2020 BAKER SOUTH RFD KITCHEN RENOVATION BUILDING CODE SUMMARYGENERAL SYMBOLS LEGEND EXTERIOR ELEVATION 1 1 1 1X-100 X-100 1 1 1 1 INTERIOR ELEVATION 1 X-100 SECTION MARKER 1 X-100 ENLARGED DETAIL CONSTRUCTION KEYED NOTE DEMOLITION KEYED NOTE DRAWING REVISION NOTE DRAWING INDEX LINETYPE: TO BE PROVIDED / NEW LINETYPE: DEMOLITION / TO BE RELOCATED LINETYPE: EXISTING TO REMAIN PROJECT SCOPE The purpose of this project is to renovate the kitchen in the RFD apartment in Baker South. Included in the scope of work is to reconfigure the space and provide new cabinets/ countertops, flooring, lighting, and heating unit. All of the existing doors will be painted and new hardware (hinges, closers. etc.) provided. PERSPECTIVE VIEWSITE LOCATION -BAKER SOUTH 3004S KEY PLAN -GROUND FLOOR # # # APPLICABLE CODES 2015 IEBC (ADOPTED BY NEW YORK STATE) 2015 IBC (ADOPTED BY NEW YORK STATE) 2015 IMC (ADOPTED BY NEW YORK STATE) 2015 IECC (ADOPTED BY NEW YORK STATE) 2016 SUPPLEMENT TO THE NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE 2017 UNIFORM CODE SUPPLEMENT (NEW YORK STATE) PROJECT SUMMARY THIS PROJECT INCLUDES THE RENOVATION OF A KITCHEN, NEW FLOORING IN HALLWAY AND PAINTING/ NEW HARDWARE ON THE EXISTING DOORS IN THE RFD APARTMENT IN BAKER SOUTH. THE WORK IS ALTERATION LEVEL 1 (DOORS/ FLOORING) AND LEVEL 2 FOR (KITCHEN). BUILDING LIMITATIONS CONSTRUCTION CLASSIFICATION:2A CLASSIFICATION OF HAZARDS:NONE HIGH-RISE BUILDING:NO EXTINGUISHING REQUIREMENT:THE EXISTING BUILDING IS SPRINKLERED OCCUPANCY OCCUPANCY CLASSIFICATION:RESIDENTIAL (R-2) BAKER SOUTH -GROUND FLOOR 1 02/14/2020 ISSUE FOR 100% SD REVIEW 2 03/24/2020 ISSUE FOR 95% REVIEW 3 04/10/2020 ISSUE FOR COORDINATED REVIEW 4 04/15/2020 ISSUE FOR CONSTRUCTION UPDNUPWALL -EXISTING WALL -METAL STUD/ GWB WALL -CONCRETE WALL -CMU WALL -BRICK ITEMS FOR DEMOLITION DOOR/ WALL -EXISTING DOOR/ WALL -NEW DOOR/ WALL -DEMOLITION TAG -DOOR TAG -WINDOW TAG -WALL TAG -ROOM # CENTER LINE PHOTO REFERENCE LEVEL MARKER COLUMN GRID MARKER ELEVATION MARKER ELEVATION CHANGE ARROWS BREAK LINE SYMBOLS 0' -0" 101 1t X-X X 2B00UA CL 1 Name Elevation A101 1 1 1 0 DN UP ABBREVIATIONS A &AND @ AT ACT ACOUSTICAL CEILING TILE ALT ALTERNATE ALUM ALUMINUM AVG AVERAGE AFF ABOVE FINISH FLOOR B BD BOARD BLDG BUILDING BOD BOTTOM OF DECK BSMT BASEMENT C CG CORNER GUARDS CJ CONTROL JOINT CLG CEILING CL CENTER LINE CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONF CONFERENCE CONT CONTINUOUS CORR CORRIDOR CPT CARPET CRS COURSE(S) CT CERAMIC TILE D DEMO DEMOLITION DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DO DOOR OPENING DWG DRAWING E EA EACH EJ EXPANSION JOINT ELEC ELECTRIC ELEV ELEVATION/ ELEVATOR EPDM RUBBER ROOF MEMBRANE EQ EQUAL EX'G EXISTING EXT EXTERIOR F FD FLOOR DRAIN FDN FOUNDATION FEC FIRE EXTINGUISHER CABINET FFE FINISH FLOOR ELEVATION FRP FIBER REINFORCED POLYESTER FT FOOT/FEET FTG FOOTING G GA GAGE GALV GALVANIZED GC GENERAL CONTRACTOR GEN GENERAL GL GLASS GWB GYPSUM WALL BOARD H HC HANDICAPPED HT HEIGHT HM HOLLOW METAL HR HOUR HVAC HEATING, VENTILATING & AC J JAN JANITOR L LAV LAVATORY LB/#POUND LGMF LIGHT GAGE METAL FRAMING M MFR MANUFACTURER MAT MATERIAL MAX MAXIMUM MEZZ MEZZANINE MIN MINIMUM MO MASONRY OPENING MTL METAL N NA NOT APPLICABLE NIC NOT IN CONTRACT NR NOT RATED NTS NOT TO SCALE O OC ON CENTER OD OUTSIDE DIAMETER OPNG OPENING OSB ORIENTER STRAND BOARD P +/-PLUS OR MINUS PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED Q QTY QUANTITY R R RISER RD ROOF DRAIN REF REFRIGERATOR REQ REQUIRED REV REVISION RO ROUGH OPENING RTU ROOF TOP UNIT S SHTG SHEATHING SIM SIMILAR SF SQUARE FOOT/ FEET SS STAINLESS STEEL STL STEEL STD STANDARD T T TREAD T&G TONGUE & GROOVE TEL TELEPHONE TEMP TEMPERATURE TOS TOP OF STEEL TV TELEVISION TYP TYPICAL U UEV UNEVEN DOORS W/ VISION PANEL UEF UNEVEN FLUSH DOOR V VCT VINYL COMPOSITION TILE VIF VERIFY IN FIELD W W/O WITHOUT WD WOOD AREA OF WORK - ALTERATION - LEVEL 2 - RECONFIGURE OF KITCHEN G17G AND DEMO OF ROOM G17H G17G G17 G17A G17C G17F G17B G17H AREA OF WORK - ALTERATION - LEVEL 1 -DOORS PAINTED AND NEW HARDWARE INSTALLED AREA OF WORK - ALTERATION - LEVEL 1 - REMOVAL OF EXISTING FLOORING AND NEW LVT INSTALLED AREA OF WORK - ALTERATION - LEVEL 1 -DOORS PAINTED AND NEW HARDWARE INSTALLED G17E G17DG00CF G00CG CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER SOUTH BAKER SOUTH RFD KITCHEN RENOVATION A-001 12309492 GENERAL NOTES, SYMBOLOGY, AND ABBREVIATIONS J. COOLBAUGH JGC 3004S APRIL 15, 2020 SCOPE OF WORK 1.0 REMOVE EXISTING CABINETS, COUNTERTOP, CEILING, AND APPLIANCES. 2.0 REMOVE EXISTING FLOOR AND INSTALL NEW LVT FLOORING. 3.0 PROVIDE NEW CABINETS, COUNTERTOP, AND APPLIANCES. INSTALL NEW CEILING. 4.0 CUT DOWN EXISTING PASS THRU OPENING. GENERAL NOTES 1.0 DESIGN, CONSTRUCTION AND SAFETY SHALL CONFORM TO ALL LOCAL, STATE AND OWNER SPECIFIC CODES, INCLUDING (BUT NOT LIMITED TO) THE NEW YORK STATE UNIFORM FIRE PROTECTION AND BUILDING CODE, LATEST REVISION, THE NFPA 101 LIFE SAFETY CODE, LATEST REVISION, ANSI A117.1 - LATEST REVISION, OSHA, AND ANY OTHER CODES GOVERNED BY THE JURISDICTION IN WHICH THIS PROJECT IS BEING CONSTRUCTED. 2.0 THIS CONTRACT REQUIRES COMPLETE, FINISHED WORKABLE PROJECT OF THE AREAS INDICATED BY THE CONTRACT DOCUMENTS, AND SHALL INCLUDE ALL MATERIALS AND LABOR NECESSARY TO COMPLETE, REGARDLESS OF WHETHER OR NOT ALL WORK OR EACH ITEM IS SPECIFICALLY INDICATED ON ANY OTHER PORTION OF THE DRAWINGS AND / OR NOTES. 3.0 WHERE MATERIALS REFERENCED ON DRAWINGS, OR NECESSARY TO COMPLETE THE WORK OF THIS CONTRACT ARE NOT SPECIFIED HEREIN, PROVIDE BEST QUALITY MATERIALS. WHERE MATERIALS ARE INTENDED TO MATCH EXISTING, PROVIDE CLOSEST POSSIBLE MATCH, SUBJECT TO OWNER'S APPROVAL. ALL ITEMS AND WORK ON DRAWINGS ARE NEW, UNLESS INDICATED EXISTING. ALL WORK WHICH HAS BEEN DAMAGED SHALL BE REPAIRED OR REPLACED AT NO COST TO THE OWNER. WHERE ITEMS CAN NOT BE REPAIRED TO A ""NEW CONDITION"", OR WHERE THE STRUCTURAL INTEGRITY HAS BEEN AFFECTED, ITEMS SHALL BE REPLACED AT NO COST TO THE OWNER. 4.0 CONTRACTOR IS RESPONSIBLE TO VERIFY ALL SITE, FIELD AND BUILDING CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. IF THERE ARE ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS, NOTIFY THE PROJECT MANAGER, WHO WILL REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER AND PROVIDE CLARIFICATION IN WRITING. 5.0 WHERE EXISTING CONSTRUCTION OR ITEMS HAVE BEEN INFILLED, REMOVED AND / OR DISTURBED FOR INSTALLATION OF NEW WORK, CAUSING THE EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES RESULTING SURFACES AND INFILLED SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. ALL ABANDONED OPENINGS (i.e. DUCT/PIPE REMOVALS, ETC.) AT WALLS, ROOF OR FLOOR TO BE INFILLED SOLID. 6.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE WORK OF OTHER TRADES (i.e. ELECTRICAL, MECHANICAL). ALTHOUGH NOT NECESSARILY SHOWN ON DRAWINGS, WORK IS REQUIRED IN THESE AREAS CONSISTING OF REMOVAL / REPLACEMENT OF CEILINGS, WALLS, FINISHES, PAVEMENT AND OTHER CONSTRUCTION AS NECESSARY TO PERFORM WORK AND RESTORE THESE SPACES OR AREAS TO ORIGINAL CONDITION. 7.0 GENERAL CONTRACTOR IS TO COORDINATE WORK OF ALL TRADES. SCHEDULE WORK PROGRESS THROUGHOUT THE ENTIRE PROJECT TO PREVENT CONFLICTS AND INTERFERENCES. OBTAIN ALL NECESSARY INFORMATION SUCH AS SIZES, LOCATIONS, TEMPLATES, LAYOUT, DIMENSIONS AND ALL OTHER INFORMATION NECESSARY FOR A PROPER AND WELL COORDINATED INSTALLATION. PRIOR TO INSTALLATION OF ITEMS, VERIFY AND CONFIRM WITH EACH CONTRACTOR EXACT LOCATION OF ALL ITEMS. 8.0 ALL PENETRATIONS (EXISTING OR NEW) THROUGH FLOORS AND FULL HEIGHT WALLS - IN AREA OF WORK TO BE FIRE STOPPED. ALL GAPS AND JOINTS AT RATED FLOORS, ROOFS AND WALLS TO BE FIRE & SMOKE STOPPED. GAPS AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND CONTROL OR EXPANSION JOINTS. FIRE STOPPING INCLUDES BOTH FORM OR PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. PROVIDE AND INSTALL LABELING REQUIRED BY CODE. LABELS SHALL INCLUDE PENETRATION TYPE WITH UL LISTING USED, MATERIAL USED, DATE INSTALL AND NAME OF INSTALLER. 9.0 JOBSITE WILL BE CLEANED DAILY AND DEBRIS REMOVED TO CONTAINERS OR TO VEHICLE WHICH WILL REMOVE DEBRIS FROM CAMPUS. CONTAINERS WILL BE REMOVED AS SOON AS FULL OR WHEN THE PROJECT HAS PROGRESSED TO A POINT THAT A CONTAINER IS NO LONGER REQUIRED. 10.0 CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL AREAS USED TO BRING SUPPLIES AND EQUIPMENT INTO THE PROJECT AREA. ANY DAMAGE TO AREAS OUTSIDE THE PROJECT AREA INCLUDING BUT NOT LIMITED TO THE LOBBY AND CORRIDOR SHALL BE REPAIRED AT NO COST TO THE OWNER. SCALE:1/8" = 1'-0"1 CODE PLAN 0' 4' 8'16' SCALE: 1/8"=1'-0" 1 02/14/2020 ISSUE FOR 100% SD REVIEW 2 03/24/2020 ISSUE FOR 95% REVIEW 3 04/10/2020 ISSUE FOR COORDINATED REVIEW 4 04/15/2020 ISSUE FOR CONSTRUCTION UPDNG17 G17B G17A GOOCG G17F G17E G17C G17D G00CF 4 6 7 7 7 7 9 1 2 4 22 3 5 3 G17G G17H 3 8 8' - 3" 5 B04 B03 B01 B00T B00U B02 B00C B00S REMOVE UP TO 6 PANES OF GLASS FROM TOP OF EXISTING WINDOW (POSSIBLE ABATEMENT NEEDED PRIOR TO ANY REMOVAL). REMOVE THE MUNTINS. PROVIDE INSULATED METAL PANEL SIMILAR TO MAPES PANEL AND ATTACH TO EXISTING WINDOW. SEAL ALL EDGES AROUND PANEL AND DUCT. COLOR TBD. COORDINATE LOCATION WITH MECHANICAL DRAWINGS.CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER SOUTH BAKER SOUTH RFD KITCHEN RENOVATION A-101 12309492 DEMOLITION PLAN - GROUND FLOOR & RENOVATION PLAN - BASEMENT J. COOLBAUGH JGC 3004S APRIL 15, 2020 A-101 KEYED DEMOLITION NOTES 1 REMOVE EXISTING CABINETS, COUNTERTOPS AND ALL BLOCKING. 2 REMOVE EXISTING APPLIANCES. 3 REMOVE EXISTING QUARRY TILE AND SETTING BED. 4 REMOVE EXISTING GYPSUM CEILING. 5 REMOVE A PORTION OF EXISTING WALL. 6 REMOVE EXISTING WALL AND DOOR. 7 REMOVE EXISTING DOOR LEAF FOR PAINTING. REMOVE AND REINSTALL EXISTING LOCKSET. 8 REMOVE EXISTING WOOD BASE. SALVAGE FOR REINSTALLATION AFTER NEW FLOORING IS INSTALLED. 9 REMOVE EXISTING DOOR LEAF FOR PAINTING. REMOVE EXISTING DOOR HARDWARE. # 0' 2' 4' 8' SCALE: 1/4"=1'-0" SCALE:1/4" = 1'-0"1 DEMOLITION PLAN - GROUND FLOOR SCALE:1/4" = 1'-0"2 RENOVATION PLAN - BASEMENT 1 02/14/2020 ISSUE FOR 100% SD REVIEW 2 03/24/2020 ISSUE FOR 95% REVIEW 3 04/10/2020 ISSUE FOR COORDINATED REVIEW 4 04/15/2020 ISSUE FOR CONSTRUCTION Ref DW 3 A-102 A-102 4 A-102 2 5 G17 G17A G17FGOOCG G17E G17B G17C G17D G00CF 2 3 4 27 1/4"12"5 5 5 5 6 EX.LVTLVT 1 1 7' - 3"3' - 2"3' - 0 5/8" V.I.F. 13' - 5 5/8" +/- 5 2 ALIGN NEW WALLS WITH EXISTING (TYP) PROVIDE WOOD BASE TO MATCH EXISTING PROFILE. PROVIDE QUARTER ROUND AROUND WALLS AFTER THE FINISH FLOOR IS INSTALLED. PROVIDE WOOD BASE TO MATCH EXISTING PROFILE. PROVIDE QUARTER ROUND AROUND WALLS AFTER THE FINISH FLOOR IS INSTALLED. 3 A-102 OPENING4' - 0"A.F.F.3' - 6"PT-2 6"36"18"30"1 1/2"30" 1 1/8" 27"3"12"84"1"27"36"24"11" 1 1/2" 30" 1 1/8" 27"3" V.I.F. 161 5/8" +/-36"OPENING48"4 1/4"8' - 3"5' - 2 5/8" +/- NEW SOFFIT (TYP AROUND TOP OF CABINETS)30"18"36"6"84"3"27"27"30"1"36"1"36"5/8" V.I.F. 161 5/8" +/- 3"27"27"30"38"12"PT-1 NEW SOFFIT (TYP AROUND TOP OF CABINETS)OPENING4' - 0"LIVING ROOM SIDE3' - 6"KITCHEN SIDE3' - 0"V.I.F. 3' - 1 1/2" 1" OVERHANG (TYP) G17G G174 1/4" +/-6"CEILING HEIGHT7' - 4 1/4" +/-PROVIDE 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD ON KITCHEN SIDE (TYP). PROVIDE BLOCKING IN WALL WHERE BASE/ WALL CABINETS ARE TO BE LOCATED. TAPE, SPACKLE, PRIME AND PAINT (PT-1). PROVIDE METAL STUD TOP TRACK. VERIFY STUD SIZE. PROVIDE PLYWOOD SUBCOUNTER TO SUPPORT NEW CORIAN COUNTERTOP (TYP). PATCH EXISTING GYPSUM WALL BOARD. TAPE, SPACKLE, PRIME AND PAINT (PT-2). PATCH EXISTING GYPSUM WALL BOARD. TAPE, SPACKLE, PRIME AND PAINT (PT-2). PROVIDE 2 1/2" 20GA METAL STUD AT 16" O.C. AND 1/2" GYPSUM WALL BOARD CEILING. TAPE, SPACKLE, PRIME AND PAINT (PT-3).CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER SOUTH BAKER SOUTH RFD KITCHEN RENOVATION A-102 12309492 RENOVATION PLANS, ELEVATIONS AND SECTION J. COOLBAUGH JGC 3004S APRIL 15, 2020 SCALE:1/4" = 1'-0"1 RENOVATION PLAN GENERAL NOTES: 1. FIELD VERIFY ALL DIMENSIONS PRIOR TO CABINET/APPLIANCE INSTALLATION NOTE MINIMUM CLEARANCE REQUIREMENTS. 2. PROVIDE FILLERS AS REQUIRED TO ALLOW PROPER CLEARANCE FOR DRAWERS, DOORS, & HARDWARE. 3. PATCH WALLS AND CEILING WITH LIKE MATERIALS AFTER THE REMOVAL OF EQUIPMENT, DOORS, WALLS, WINDOWS, ETC. PRIME AND PAINT. KITCHEN CABINETS AND COUNTERTOP: CABINETS -DURA SUPREME -CRESTWOOD HUDSON DOOR IN OAK • ALL PLYWOOD CONSTRUCTION, SOLID HARDWOOD DOVETAILED DRAWERS • SOFT CLOSE HINGES AND FULL EXTENSION, SOFT CLOSE DRAWER TRACKS BY BLUM • HARDWARE -LIBERTY 3" STEEL BAR PULL 1. SATIN NICKEL FINISH -P27507H-SN-X1 • 5-10 YEAR WARRANTY • FULLY SEALED FINISH • COLOR: COCOA BROWN COUNTERTOPS -CORIAN BY DUPONT, • 3/4" THICK WITH DOUBLE PENCIL EDGE • 4" BACKSPLASH & SIDESPLASH COLOR: RAIN CLOUD PAINT: • PT-1 -WALL PAINT KITCHEN 1. BENJAMIN MOORE, REGAL SELECT -AMERICAN WHITE –2112-70, PEARL FINISH • PT-2 -WALL PAINT LIVING ROOM 1. BENJAMIN MOORE, REGAL SELECT -STORMY MONDAY –211-50, PEARL FINISH • PT-3 -CEILING PAINT 1. BENJAMIN MOORE, REGAL SELECT –WHITE -FLAT • PT-4 - WALL BASE, DOOR AND TRIM 1. BENJAMIN MOORE, REGAL SELECT -WHITE OPULENCE –OC-69 -SEMI- GLOSS FINISH FLOORING: 1. PROVIDE ARDEX OR BOSTIK SELF LEVELING UNDERLAYMENT LUXURY VINYL PLANK: • KITCHEN FLOOR –MOHAWK VEPID STEP STONE -S999 STORMY NIGHTS • ENTRY –EXTENSION FROM EXISTING A-102 GENERAL RENOVATION NOTES 1.0 PATCH FLOORS WHERE WALLS HAVE BEEN DEMOLISHED TO MATCH EXISTING SLAB ELEVATION AND PREP FOR NEW FLOOR FINISH. REFER TO ROOM FINISH SCHEDULE FOR NEW FLOOR FINISHES. 2.0 ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. SCALE:NO SCALE4INTERIOR ELEVATION - LIVING ROOM SCALE: NO SCALE 2 INTERIOR ELEVATION #2 - KITCHEN G17G SCALE: NO SCALE 5 INTERIOR ELEVATION #1 - KITCHEN G17G SCALE:3/4" = 1'-0"3 WALL SECTION AT PASS-THRU 0' 2' 4' 8' SCALE: 1/4"=1'-0" A-102 KEYED RENOVATION NOTES 1 PROVIDE NEW LVT FLOORING. SEE FLOORING NOTES FOR SPEC INFORMATION. 2 PROVIDE 3 5/8" METAL STUD WITH 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD CHASE WALL. TAPE, SPACKLE, PRIME AND PAINT PT-1. 3 PROVIDE NEW TALL PANTRY CABINET. 4 PATCH WALL TO MATCH EXISTING ADJACENT CONDITIONS. TAPE, SPACKLE, PRIME AND PAINT PT-1. 5 PAINT EXISTING DOORS PT-4. REINSTALL LOCKSET AND PROVIDE NEW HINGES AS PER HARDWARE NOTES. 6 PAINT EXISTING DOOR PT-4. PROVIDE NEW LOCKSET, HINGES, AND CLOSER AS PER HARDWARE NOTES. DOOR HARDWARE: • HINGES –MCKINNEY –TA2714 –US15 (VERIFY SIZE OF EXISTING) • STRIKE PLATE –DON JO -ANSI STRIKE (VERIFY SIZE OF EXISTING AND COORDINATE WITH NEW LOCKSET) • CLOSER –SARGENT -351 X UO X 15 X 90 DEG • DOOR WRAP AROUND (ENTRY DOOR ONLY)-DON JO -WRAP AROUND (VERIFY SIZE WITH EXISTING MORTISE LOCKSET) DOOR WILL NEED TO BE MODIFIED FOR NEW CYLINDRICAL LOCK. PROVIDE ALL PLATES ETC. FOR CONVERSION. SCALE: 3/4"=1'-0" 0" 1' 2' 3'6" APPLIANCES:TO BE SUPPLIED BY SCL • REFRIGERATOR -WHIRLPOOL, MODEL# WRF535SWHZ • DISHWASHER -KITCHEN AID, MODEL# KDFE104HPS • RANGE -GE, MODEL# JS760SLSS • MICROWAVE (OVER-THE-RANGE)-GE, MODEL# PVM9005SJSS 1 02/14/2020 ISSUE FOR 100% SD REVIEW 2 03/24/2020 ISSUE FOR 95% REVIEW 3 04/10/2020 ISSUE FOR COORDINATED REVIEW 4 04/15/2020 ISSUE FOR CONSTRUCTION CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER SOUTH BAKER SOUTH RFD KITCHEN RENOVATION MP-001 12309492 GENERAL NOTES AND SYMBOL LEGENDS A. FOX ALF 3004S APRIL 15, 2020 MECHANICAL ABBREVIATIONS BCU BLOWER COIL UNIT CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY CC CLEAN CONDENSATE CO CLEAN OUT CS CLEAN STEAM CD CONDENSATE DRAIN EA EXHAUST AIR EAG EXHAUST AIR GRILLE FD FIRE DAMPER GWR GLYCOL HEATING RETURN GWS GLYCOL HEATING SUPPLY HPR HIGH PRESSURE STEAM RETURN HPS HIGH PRESSURE STEAM SUPPLY HWR HOT WATER HEATING RETURN HWS HOT WATER HEATING SUPPLY LPC LOW PRESSURE CONDENSATE LPS LOW PRESSURE STEAM MU MAKE UP WATER MPC MEDIUM PRESSURE CONDENSATE MPS MEDIUM PRESSURE STEAM NG NATURAL GAS PCWR PROCESS CHILLED WATER RETURN PCWS PROCESS CHILLED WATER SUPPLY HG REFRIGERANT HOT GAS RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION RAG RETURN AIR GRILLE SA SUPPLY AIR SAD SUPPLY AIR DIFFUSER VD VOLUME DAMPER MECHANICAL SYMBOLOGY AIRFLOW BACKFLOW PREVENTER BALANCE VALVE BALL VALVE BOTTOM PIPE CONNECTION BUTTERFLY VALVE CAP OR PLUG CHECK VALVE CIRCULATING PUMP DIRECTION OF FLOW DUCT AIRFLOW DUCT DOWN (EXHAUST OR RETURN) DUCT DOWN (SUPPLY) FIRE AND SMOKE DAMPER IN DUCT FIRE DAMPER IN DUCT FLANGE CONNECTION FLEX CONNECTOR FLEXIBLE CONNECTION FLEXIBLE DUCT FLOW METER FLOW SWITCH FUSIBLE LINK VALVE GLOBE VALVE MANUAL AIRVENT ORIFICE METER PIPE DOWN PIPE UP PIPING REDUCER (CONCENTRIC) PIPING REDUCER (ECCENTRIC) PRESSURE GAUGE PRESSURE OR TEMPERATURE PETES PLUG PRESSURE REDUCING VALVE PRESSURE SWITCH RECTANGULAR ELBOW RECTANGULAR ELBOW WITH TURNING VANES RELIEF VALVE SMOKE DAMPER IN DUCT SOLENOID VALVE STANDARD BRANCH DUCT STEAM TRAP STRAINER (DUPLEX) STRAINER WITH BLOWDOWN VALVE AND CAP SUPPLY THROUGH NEXT FLOOR OR ROOF TEMPERATURE WELL THERMOMETER THERMOMETER (DIAL) TOP PIPE CONNECTION TRIPLE DUTY VALVE UNION CONNECTION VACUUM BREAKER VOLUME DAMPER IN DUCT CONTROL SYMBOLOGY 2-WAY CONTROL VALVE, DIGITAL 2-WAY CONTROL VALVE, PNEUMATIC 3-WAY CONTROL VALVE, DIGITAL 3-WAY CONTROL VALVE, PNEUMATIC ADDRESSABLE OUTPUT MODULE (FIRE ALARM INTERFACE) AIRFLOW CONTROL VALVE (VENTURI OR VORTEX SHEDDING) AVERAGING SENSOR BINARY POINT BUTTERFLY CONTROL DAMPER CARBON DIOXIDE SENSOR CONDENSATE SENSOR CURRENT SENSOR DEW-POINT SENSOR DIFFERENTIAL PRESSURE SENSOR DIFFERENTIAL PRESSURE SENSOR ELECTRIC TO PNEUMATIC SWITCH ELECTRIC TO PNEUMATIC TRANSDUCER END SWITCH FLOW ELEMENT (METER) FLOW SENSOR HIGH LEVEL SWITCH HUMIDSTAT SENSOR LIQUID IMERSION TEMPERATURE SENSOR LOW LEVEL SWITCH MODULATING MOTOR MOTOR STARTER NETWORK COMMUNICATION POINT, BACnet MSTP OCCUPANCY SENSOR OPEN/CLOSE OPPOSED BLADE CONTROL DAMPER PARALLEL BLADE CONTROL DAMPER PNEUMATIC THERMOSTAT PRESSURE SENSOR PRESSURE SWITCH RELATIVE HUMIDITY SENSOR RELAY ROOM TEMPERATURE SENSOR WITH ADJUSTABLE THERMOSTAT ROOM TEMPERATURE SENSOR WITH OCCUPANCY OVERRIDE ROOM TEMPERATURE SENSOR WITH ON/OFF SWITCH ROOM TEMPERATURE SENSOR WITH VISUAL DISPLAY ROTATION DETECTOR SINGLE POINT SENSOR SMOKE DETECTOR SPEED COMMAND START/STOP STATIC PRESSURE SENSOR SWITCH TEMPERATURE SENSOR TEMPERATURE SENSOR TEMPERATURE SENSOR WITH ADJUSTABLE SETPOINT GENERAL DRAWING SYMBOLOGY DEMOLISHED WORK EXISTING PIPING TO REMAIN EXISTING TO REMAIN EXISTING WORK TO REMAIN NEW WORK POINT OF CONNECTION POINT OF DISCONNECTION CONTROL ABBREVIATIONS AI ANALOG INPUT AO ANALOG OUTPUT AV ANALOG VALUE BI BINARY INPUT BO BINARY OUTPUT BV BINARY VALUE F.L. FAIL LAST N.C. NORMALLY CLOSED N.O. NORMALLY OPEN VFD VARIABLE FREQUENCY DRIVE MECHANICAL SCOPE OF WORK 1.0 EXTEND DUCT TO NEW RANGE HOOD. 2.0 REPLACE EXISTING FINTUBE WITH NEW. MECHANICAL GENERAL NOTES 1.0 ALL DUCT DIMENSIONS INDICATED ARE IN INCHES, AND ARE INSIDE FREE AND CLEAR DIMENSIONS. 2.0 PNEUMATIC TERMINATIONS: IF COPPER: DEMO BACK TO MAIN AND PROVIDED SOLDERED END CAP IF POLY: DEMO BACK TO MAIN AND PROVIDE BRASS PLUG DO NOT USE SHEETMETAL SCREW OR BEND OVER END OF COPPER TUBE. 3.0 INSTALL EQUIPMENT TO ENSURE PROPER ACCESS TO CONTROL DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. EQUIPMENT THAT IS NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. 4.0 ALL SYSTEM TESTING SHALL BE CONDUCTED PRIOR TO INSULATION, FIREPROOFING, AND ENCLOSURE IN SHAFTS. ANY RESTORATION WORK REQUIRED AS A RESULT OF DISTURBING FINISHES OR STRUCTURE IN ORDER TO ACCESS SYSTEMS REQUIRING REPAIR SHALL BE AT NO COST TO THE UNIVERSITY. 5.0 CUTTING AND PATCHING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING, AND PATCHING TO COMPLETE THE WORK. WHERE EXISTING CONSTRUCTION IS REMOVED, CAUSING AN EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES, RESULTING SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. 6.0 ANY FIRESTOPPING DISTURBED DURING THE COURSE OF WORK SHALL BE REPAIRED TO MAINTAIN A 2-HOUR FIRE RATING. 7.0 TESTING AND BALANCING: THE CONTRACTOR SHALL BALANCE ALL AIR SYSTEMS AS INDICATED. SUBMIT RESULTS OF TESTING AND BALANCING ON STANDARD TAB CONTRACTOR'S FORMS TO THE ENGINEER FOR REVIEW. SYSTEMS SHALL BE BALANCED TO WITHIN +/- 10% OF DESIGN VALUES. FINAL BALANCING SHALL OCCUR AFTER ALL LEAKS IN THE BUILDING ENVELOPE HAVE BEEN IDENTIFIED AND SEALED. 8.0 SEAL ALL PIPE, GRILLE, DIFFUSER, DUCT, CONDUIT PENETRATIONS WITH APPROPRIATE MATERIALS (CAULK, FOAM, ETC,) THAT ARE IMPENETRABLE TO THE CONTAINED ORGANISMS AND WITHSTAND REPEATED DECONTAMINATIONS WITH CLEANING AGENTS. MECHANICAL SUBMITTAL SCHEDULE SECTION TITLE REQUIRED 230000 HEATING, VENTILATING & AIR-CONDITIONING - 230523 GENERAL DUTY VALVES FOR HVAC PIPING PRODUCT DATA 230529 HANGERS & SUPPORTS FOR HVAC PRODUCT DATA 230553 IDENTIFICATION FOR HVAC COMPONENTS PRODUCT DATA 230593 TESTING, ADJUSTING & BALANCING FOR HVAC QUALIFICATIONS, INSPECTION AND TEST REPORTS 230700 HVAC DUCT INSULATION PRODUCT DATA 230719 HVAC PIPING INSULATION PRODUCT DATA 230900 INSTRUMENTATION & CONTROL FOR HVAC PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 232113 HYDRONIC PIPING PRODUCT DATA 233113 METAL DUCTS PRODUCT DATA 1 02/14/2020 ISSUE FOR 100% SD REVIEW 2 03/24/2020 ISSUE FOR 95% REVIEW 3 04/10/2020 ISSUE FOR COORDINATED REVIEW 4 04/15/2020 ISSUE FOR CONSTRUCTION REF.Ref DW UPDN1 2 1 REMOVE EXISTING FIN TUBE AND PREPARE PIPE FOR NEW 34 VERIFY DUCT IN FIELD FT-1 4 MP-101 PROVIDE NEW 3"x10" DUCT FROM NEW GE EXHAUST HOOD/MICROWAVE DOWN THROUGH FLOOR 2 3 4 T 2TS-1 5 4 MP-101 B00U B03 B02 B01 B04 B00T 1 GROUND FLOOR -1' -0" 1ST FLOOR 9' -0" BASEMENT -11' -0" EXHAUST WALL CAP 6"Ø EXHAUST 3" x 10" EXHAUST DUCT CONNECTION TO NEW MICROWAVE/EXHAUST COMBO TRANSITION FROM RECTANGULAR DUCT 6"Ø EXHAUST DUCT COORDINATE NEW 6" EXHAUST DUCT PENETRATION WITH REMOVED 4" EXHAUST DUCT PENETRATION FROM OLD OVEN/STOVE COORDINATE NEW 6" EXHAUST DUCT PENETRATION WITH REMOVED 4" EXHAUST DUCT PENETRATION. REFERENCE ARCHITECTURAL DRAWINGS FOR HOW PENETRATION IS TO BE SEALED.CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER SOUTH BAKER SOUTH RFD KITCHEN RENOVATION MP-101 12309492 GROUND FLOOR MECHANICAL & PLUMBING DEMOLITION & INSTALLATION PLANS A. FOX ALF 3004S APRIL 15, 2020 # SCALE: 3/16"=1'-0" 0 2 4 6 12 MP-101 KEYED DEMOLITION NOTES 1 REMOVE EXISTING EXHAUST GRILLE AND CAP DUCT ABOVE CEILING. 2 REMOVE EXISTING SINK. REMOVE ASSOCIATED DRAIN/VENT AND WATER PIPE. CAP AT FLOOR AND WALL. 3 DISCONNECT EXISTING WATER LINE TO DISH WASHER AND PREPARE FOR RECONNECTION TO NEW DISHWASHER. 4 DISCONNECT EXISTING COLD WATER PIPING TO SINK AND UNDER COUNTER INSTANT HOT WATER HEATER. DISCONNECT DRAIN FROM SINK. PREPARE DRAIN AND WATER PIPING FOR RECONNECTION TO NEW SINK. SCALE:3/16" = 1'-0"1 GROUND FLOOR MECHANICAL DEMOLITION PLAN SCALE:3/16" = 1'-0"3 GROUND FLOOR MECHANICAL INSTALLATION PLAN SCALE:3/16" = 1'-0"2 BASEMENT MECHANICAL PLAN SCALE:NO SCALE4MICROWAVE/EXHAUST HOOD COMBO EXHAUST DUCT LAYOUT MP-101 KEYED CONSTRUCTION NOTES 1 REFERENCE DETAIL 4/MP-101 FOR COMBINATION MICROWAVE/EXHAUST HOOD EXHAUST DUCT LAYOUT. 2 PROVIDE NEW CONTROL VALVE (CV-1) FOR NEW RUNTAL. PROVIDE LOCAL CONTROL VIA THE TEMPERATURE SENSOR MOUNTED TO THE WALL. PROVIDE NEW BALANCE VALVE (BV-1) AND ISOLATE FINTUBE WITH ISOLATION VALVES (V-1). 3 RECONNECT DRAIN, DOMESTIC HOT AND COLD WATER PIPING TO THE SINK AND FAUCET. 4 CONNECT UNDER COUNTER INSTANT WATER HEATER TO COLD WATER PIPING. WATER HEATER SHALL BE PROVIDED BY THE OWNER AND INSTALLED BY THE CONTRACTOR. CONFIRM WATER HEATER MODEL AND MANUFACTURER WITH OWNER PRIOR TO PIPING INSTALLATION. 5 RECONNECT DRAIN AND WATER SUPPLY TO DISHWASHER. PROVIDE PROPER CHECK VALVES TO PROTECT CITY WATER PIPING. # SEQUENCE OF OPERATION SYSTEM DESCRIPTION FINTUBE RADIATION (FT-1) GENERAL SYSTEM SHALL BE CONTROLLED MANUALLY AND LOCALLY. ALL SETPOINTS SHALL BE ADJUSTABLE. DESIGN INTENT: THE NEW FINTUBE (FT-1), LOCATED IN THE KITCHEN, SHALL BE CONTROLLED LOCALLY BY THE NEW TEMPERATURE SENSOR (TS-1), LOCATED AS SHOWN IN THE DRAWINGS. THE OTHER FINTUBE WITHIN THE APARTMENT SHALL CONTINUE TO BE CONTROLLED AS IS. SETPOINTS SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED:72°F +/-2°F ZONE TEMPERATURE CONTROL OCCUPIED HEATING: THE FINTUBE CONTROL VALVE SHALL MODULATE AS NECESSARY TO MAINTAIN EXISTING HEATING SETPOINT. 1 02/14/2020 ISSUE FOR 100% SD REVIEW 2 03/24/2020 ISSUE FOR 95% REVIEW 3 04/10/2020 ISSUE FOR COORDINATED REVIEW 4 04/15/2020 ISSUE FOR CONSTRUCTION CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER SOUTH BAKER SOUTH RFD KITCHEN RENOVATION MP-501 12309492 SCHEDULES A. FOX ALF 3004S APRIL 15, 2020 DUCT SCHEDULE AND SPECIFICATIONS SERVICE PRESSURE CLASS SEAL CLASS LEAKAGE CLASS DUCT MATERIAL LINING DUCT INSULATION EXHAUST RECTANGULAR, CONCEALED 2" POS A 6 G90 GALVANIZED NONE NONE EXHAUST ROUND, CONCEALED 2" POS A 3 G90 GALVANIZED NONE NONE CONTROL VALVE SCHEDULE & SPEC TAG MANF VALVE MODEL OPERATOR MODEL SIZE (IN)CV CAPACITY (GPM) MAX PD (PSIG)TYPE NOTES CV-1 BELIMO CCV-B210 TF24-SR-T US 1/2 1.2 0.5 4 2-WAY, PROPORTIONAL, NON-SPRING RETURN FAIL LAST FINTUBE RADIATION SCHEDULE TAG LOCATION BOD MANF BOD MODEL TUBE DIA (IN) HEAT OUTPUT (BTUH/LF) RUNTAL LENGTH (LF) TOTAL OUTPUT (BTUH) FLOW RATE (GPM) ENT AIR TEMP (˚ F) AVG WATER TEMP (˚ F)NOTES FT-1 G17 RUNTAL RADIATORS UF-4 1/2" NTP 930 3 2,790 0.5 170 190 1 SPECS: 1 ACCEPTABLE MANUFACTURERS: BELIMO, VSI 2 ELECTRIC INPUT: 4-20mA OR 0-10VDC 3 2-WAY VALVES: EQUAL PERCENTAGE FLOW CHARACTERISTIC. 4 CONSTRUCTION: CHARACTERIZING DISK, FORGED BRASS, NICKEL PLATED BODY, STAINLESS STEEL BALL AND STEM, FIBERGLASS REINFORCED PTFE SEAT. 5 RATINGS: 400 PSI PRESSURE, 0-212 F MEDIA TEMPERATURE RANGE. 6 ALL CONTROL WIRING SHALL BE INSTALLED IN CONDUIT. CONTROL WIRING SHALL BE UNSPLICED FROM THE CONTROLLER TO THE SENSOR OR DEVICE. CONTROL WIRING SHALL NOT BE ROUTED IN THE SAME RACEWAY AS POWER WIRING. CONTROL WIRING SHALL BE COLOR CODED AND LABELED AT ALL POINTS OF TERMINATION. NOTES: 1 RUNTAL PROVIDED BY OWNER, INTALLED BY CONTRACTOR. SPECS: 1 HEAT OUTPUT INDICATED IS THE OUTPUT AT STANDARD RATING CONDITIONS CORRECTED FOR WATER VELOCITY, ENTERING AIR TEMPERATURES, AND MOUNTING HEIGHTS, AS REQUIRED. 2 ACCESSORIES: END TRIM, INSIDE CORNER, OUTSIDE CORNER, END ENCLOSURE, ACCESS PANEL. 3 INSTALL IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. PLUMBING & HVAC PIPE AND FITTING SCHEDULE AND SPECIFICATIONS PIPE SERVICE ABBREVIATION PIPE SIZE MATERIAL FITTINGS JOINT INSULATION DOMESTIC COLD WATER DCW 1/2" - 6" ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER 1", FIBERGLASS OR FLEXIBLE ELASTOMERIC DOMESTIC HOT WATER DHW 1/2" - 6" ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER 1", FIBERGLASS OR FLEXIBLE ELASTOMERIC SANITARY WASTE / VENT SAN / V ALL SIZES ASTM A74, ASTM A888 SERVICE WEIGHT CAST IRON ASTM D 1784, 1785 & 2665 PVC SCHEDULE 40 PIPE ASTM A74, ASTM A888 CAST IRON NO-HUB ASTM D 1784, 1785 & 2665 PVC SCHEDULE 40 SOLID WALL PIPE ASTM C1277 NEOPRENE GASKET SS BANDS ASTM D 2564 SOLVENT CEMENT, ASTM F 6, ASTM F 656 PRIMER NA HEATING HOT WATER HWS / R 1-1/4" & BELOW ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER 1-1/2",PRE-FORMED MINERAL FIBERGLASS, ASTM C547 TYPE I SPECS: 1 SOLDER FILLER METALS: ASTM B32, LEAD-FREE ALLOYS. INCLUDE WATER FLUSHABLE FLUX ACCORDING TO ASTM B813. 2 DIELECTRIC FITTINGS: USE FLANGES OR COUPLINGS. UNIONS ARE UNACCEPTABLE. 3 INSTALL ESCUTCHEONS FOR PENETRATIONS OF WALLS, CEILING, AND FLOORS 4 INSTALL PLUMBING SYSTEMS TO FACILITATE SERVICE, MAINTENANCE AND REPAIR OR REPLACEMENT OF COMPONENTS. 5 ALL WASTE PIPING SHALL BE PITCHED AT 1/8" PER FOOT. ALL SUPPLY PIPING SHALL BE PITCHED BACK TOWARDS CONNECTION TO THE ROOM ENTRANCE. 6 PROVIDE VAPOR RETARDER ON PIPING INSULATION SYSTEMS CARRYING FLUIDS WITH AN OPERATING TEMPERATURE LOWER THAN 60 ⁰F. 7 DO NOT ENCLOSE, COVER OR PUT PLUMBING PIPING SYSTEMS INTO OPERATION UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE AUTHORITIES HAVING JURISDICTION. 8 LEAVE NEW, ALTERED, EXTENDED, OR REPLACED DOMESTIC WATER PIPING UNCOVERED AND UNCONCEALED UNTIL IT HAS BEEN TESTED. EXPOSE WORK THAT WAS COVERED OR CONCEALED BEFORE IT WAS TESTED. 9 ALL INSULATION AND ADHESIVE SHALL HAVE A MAXIMUM FLAME-SPREAD INDEX OF 25 AND A MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84. 10 TESTING OF DOMESTIC WATER PIPING: CAP AND SUBJECT DOMESTIC WATER PIPING TO STATIC WATER PRESSURE OF 50 PSIG ABOVE OPERATING PRESSURE, WITHOUT EXCEEDING PRESSURE RATING OF PIPING SYSTEM MATERIALS. ISOLATE TEST SOURCE AND ALLOW TO STAND FOR FOUR HOURS. LEAKS AND LOSS IN TEST PRESSURE CONSTITUTE DEFECTS THAT MUST BE REPAIRED. REPAIR LEAKS AND DEFECTS WITH NEW MATERIALS AND RETEST PIPING UNTIL SATISFACTORY RESULTS ARE OBTAINED. 11 TESTING OF DOMESTIC WASTE AND VENT PIPING: CAP AND SUBJECT DOMESTIC WASTE AND VENT PIPING TO STATIC WATER PRESSURE OF 10 FEET HEAD PRESSURE ABOVE HIGHEST POINT OF SYSTEM UNDERGOING TEST. ISOLATE TEST SOURCE AND ALLOW TO STAND UNTIL SYSTEM CAN BE VISUALLY INSPECTED BY AUTHORITY HAVING JURISDICTION. LEAKS CONSTITUTE DEFECTS THAT MUST BE REPAIRED. REPAIR LEAKS AND DEFECTS WITH NEW MATERIALS AND RETEST PIPING UNTIL SATISFACTORY RESULTS ARE OBTAINED. 12 CLEANING AND DISINFECTION OF POTABLE WATER SYSTEMS: FLUSH PIPING SYSTEM WITH CLEAN, POTABLE WATER UNTIL DIRTY WATER DOES NOT APPEAR AT OUTLETS. FILL SYSTEM WITH WATER/CHLORINE SOLUTION WITH AT LEAST 50 PPM OF CHLORINE. ISOLATE WITH VALVES AND ALLOW TO STAND FOR 24 HOURS. DRAIN TO SANITARY. FLUSH SYSTEM WITH CLEAN, POTABLE WATER UNTIL NO TSP REMAINS IN WATER COMING FROM SYSTEM. SUBMIT WATER SAMPLES IN STERILE BOTTLES TO AUTHORITIES HAVING JURISDICTION. REPEAT PROCEDURE IF BIOLOGICAL EXAMINATION SHOWS EVIDENCE OF CONTAMINATION. 13 INSTALL UNIONS IN PIPING, NPS 2 AND SMALLER, ADJACENT TO VALVES, AT FINAL CONNECTIONS OF EQUIPMENT, AND ELSEWHERE AS INDICATED. SPECS: 1 ALL DUCTWORK AND ACCESSORIES SHALL BE FABRICATED AND INSTALLED IN COMPLIANCE WITH THE LATEST ISSUE OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE. 2 CONSTRUCT TEES, BENDS, AND ELBOWS WITH RADIUS OF NOT LESS THAN 1.0 TIMES THE WIDTH OF DUCT ON CENTER LINES. 3 INCREASE DUCT SIZES GRADUALLY, AND IN COMPLIANCE WITH FIGURE 4-7 OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE. 4 SEALANTS AND GASKETS: SURFACE BURNING CHARACTERISTICS SHALL BE A MAXIMUM FLAME-SPREAD INDEX OF 25, AND MAXIMUM SMOKE- DEVELOPED INDEX OF 50 WHEN TESTED TO UL 723. 5 REMOVE SURFACE CONTAMINANTS AND DEPOSITS FROM DUCTWORK AND EQUIPMENT PRIOR TO TESTING. 6 LEAK TESTING OF DUCTWORK SHALL BE IN ACCORDANCE WITH SMACNA'S HVAC AIR DUCT LEAKAGE TEST MANUAL. CONTROL DEVICE SCHEDULE TAG DESCRIPTION MANUFACTURER (BOD) MODEL (BOD)NOTES TS-1 TEMPERATURE SENSOR AUTOMATED LOGIC RS PRO 10 KΩ THERMISTER, 0.4 ˚F RESOLUTION, ±0.5 ˚F ACCURACY, WITH MANUFACTURERS STANDARD LOCKING COVER, EXPOSED WARMER/COOLER SETPOINT ADJUSTMENT, ALPHA-NUMERIC DISPLAY OF TEMPERATURE, OCCUPANCY OVERRIDE, AND CONNECTION HEAD FOR WIRING CONNECTION, TWISTED SHIELDED PAIR CABLE. RTD ACCEPTABLE IN LIEU OF THERMISTER. SPECS: 1 MOUNT WALL TEMPERATURE SENSOR PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. PIPING ACCESSORIES SCHEDULE AND SPECIFICATIONS TAG DEVICE MANUFACTURER (BOD) MODEL (BOD)PRESSURE RATING SPECIFICATIONS BV-1 BALANCE VALVE 1/2 INCH BELL & GOSSETT CB SERIES, CB1/2 200 PSIG @ 250 DEGF 0.5 GPM RANGE, BRONZE, BALL OR PLUG TYPE BODY WITH CALIBRATED ORIFICE OR VENTURI; GLASS AND CARBON FILLED TFE OR EPDM SEAT RINGS, EPDM STEM O-RING, WITH INTEGRAL SEALS FOR PORTABLE DIFFERENTIAL PRESSURE METER, WITH LEVEL HANDLE AND MEMORY STOP TO RETAIN SET POSITION. V-1 SHUT-OFF BALL VALVE WATTS B6000-SS 300 PSIG WOG MSS SP-110, 2-PIECE, STANDARD PORT, BRONZE BODY, 316 SS BALL & STEM, PTFE OR TFE SEAT 1 02/14/2020 ISSUE FOR 100% SD REVIEW 2 03/24/2020 ISSUE FOR 95% REVIEW 3 04/10/2020 ISSUE FOR COORDINATED REVIEW 4 04/15/2020 ISSUE FOR CONSTRUCTION ABBREVIATIONS A - AMPERE AFC - ABOVE FINISHED CEILING AFF - ABOVE FINISHED FLOOR AIC - AMPS INTERRUPTING CAPACITY BLDG - BUILDING C - CONDUIT CKT - CIRCUIT CL - CENTERLINE DWG - DRAWING E - EXISTING TO REMAIN EC - ELECTRICAL CONTRACTOR EM - EMERGENCY EMT - ELECTRICAL METALLIC TUBING FVNR - FULL VOLTAGE NON-REVERSING G - GROUND GC - GENERAL CONTRACTOR GFI - GROUND FAULT INTERRUPTER JB - JUNCTION BOX KVA - KILOVOLTAMPERES KW - KILOWATT MC - MECHANICAL CONTRACTOR MCB - MAIN CIRCUIT BREAKER MCW - MICROWAVE MDP - MAIN DISTRIBUTION PANEL MLO - MAIN LUG ONLY P - POLE PH - PHASE PVC - POLYVINYL CHLORIDE R - REMOVE RE - REPLACE EXISTING REL - RELOCATED RI - REMOVE AND REINSTALL RL - RELOCATE EXISTING RM - ROOM UTV - UNDERVOLTAGE TRIP V - VOLT W - WIRE WP - WEATHER PROOF XFMR - TRANSFORMER ELECTRICAL NOTES 1. ALL WORK SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE CORNELL UNIVERSITY ELECTRICAL STANDARDS. THE NATION ELECTRIC CODE(NFPA 70) AND ANY GOVERNING CODES AND STANDARDS HAVING JURISDICTION. 2. REFER TO CORNELL ELECTRICAL STANDARDS FOR ALL SPECIFICATION REQUIREMENTS. 3. ALL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE. 4. CONTRACTORS SHALL PAY FOR AND SECURE ALL PERMITS AND UNDERWRITERS CERTIFICATES. 5. PRIOR TO BID, THE CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH THE EXISTING FIELD CONDITIONS. HIS BID SHALL INCLUDE THE FURNISHING AND INSTALLATION OF ALL LABOR, TOOLS, MATERIAL, EQUIPMENT, SERVICES AND RELATED ACCESSORIES NECESSARY FOR THE COMPLETE INSTALLATION OF THE ELECTRICAL WORK SHOWN ON THE DRAWINGS AND REQUIRED BY CODE. 6. THE ELECTRICAL CONTRACTOR SHALL FURNISH ALL METERS, INSTRUMENTS, CABLE CONNECTION, EQUIPMENT, OR APPARATUS ESSAY FOR MAKING ALL TESTS. 7. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL EQUIPMENT AND SYSTEMS AGAINST HARMFUL EXPOSURE OR ACCUMULATION OF DUST/MOISTURE, CORROSION OR OTHER FORMS OF DAMAGE. CLEAN AND RESTORE DAMAGED FINISHES. 8. CONTRACTOR SHALL COORDINATE PROJECT WORK WITH ALL TRADES AND ASSIST IN SCHEDULING WITH ALL TRADES. 9. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CUTTING, PATCHING, AND REFINISHING OF WORK AREA RELATED TO ELECTRICAL PROJECT WORK. RESTORE AREA TO ORIGINAL CONDITION. 10. CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF ALL WASTE MATERIALS IN A LAWFUL MANNER AND LEAVE THE SITE FREE OF ALL DEBRIS. 11. THE TERM "PROVIDE" DENOTES TO FURNISH AND INSTALL. 12. THE TERM "WIRING" DENOTES WRING AND RACEWAY. 13. UNLESS OTHERWISE NOTED, WHERE A DEVICE OR WIRING IS REMOVED, THE CONTRACTOR SHALL DISCONNECT AND REMOVE THE ASSOCIATED WIRING AND CONTROLS. 14. WHERE A DEVICE IS RELOCATED, DISCONNECT, REMOVE AND STORE THE NOTED DEVICE. EXISTING WIRING SHALL REMAIN. PROVIDE RELOCATION OF DEVICE PER CONSTRUCTION SCHEDULE. RECONNECT TO EXISTING WIRING. EXTEND WIRING AS REQUIRED, MATCH EXISTING. 15. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SERVICE TO THE BALANCE OF ANY EXISTING CIRCUITS THAT ARE AFFECTED BY THIS PROJECT AND THAT EXTEND OUT OF THE PROJECT AREA. EXTEND WIRING AS REQUIRED, MATCH EXISTING. 16. COORDINATE ALL DEMOLITION WORK WITH CORNELL UNIVERSITY PRIOR TO ANY SHUTDOWNS OR REMOVAL OF DEVICES AND/OR WIRING. 17. COORDINATE ALL COMMUNICATIONS WORK WITH CORNELL UNIVERSITY I/T GROUP. 18. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLETING A PANEL WALK DOWN FOR EACH PANEL BEING AFFECTED FOR THIS PROJECT TO DETERMINE REQUIREMENTS AND COORDINATE SHUTDOWNS WITH CORNING. ELECTRICAL SYMBOLS LEGEND SYMBOL DESCRIPTION J JUNCTION BOX UNDER CABINET LIGHT FIXTURE RECESSED CAN LIGHT FIXTURE RECEPTACLE GFCI RECEPTACLE SMOKE DETECTOR DATA OUTLET THREE WAY SWITCH OCCUPANY SENSOR 3 HEAT DETECTOR 135 BUILDING WIRE AND CABLE A. PROVIDE PRODUCTS AS FOLLOWS: 1. SOLID CONDUCTOR FOR FEEDERS AND BRANCH CIRCUITS 10 AWG AND SMALLER. 2. STRANDED CONDUCTORS FOR CONTROL CIRCUITS. 3. CONDUCTOR NOT SMALLER THAN #12 AWG FOR POWER AND LIGHTING CIRCUITS. 4. CONDUCTOR NOT SMALLER THAN #16 AWG FOR CONTROL CIRCUITS. 5. 10 AWG CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS LONGER THAN 75 FEET. 6. 10 AWG CONDUCTORS FOR 20 AMPERE, 277 VOLT BRANCH CIRCUITS LONGER THAN 200 FEET. B. WIRING METHODS: PROVIDE THE FOLLOWING WIRING METHODS: 1. CONCEALED DRY INTERIOR LOCATIONS: USE ONLY BUILDING WIRE, TYPE THHN/THWN INSULATION, IN RACEWAY. 2. ABOVE ACCESSIBLE CEILINGS: USE ONLY BUILDING WIRE, TYPE THHN/THWN INSULATION, IN RACEWAY. 3. WET OR DAMP INTERIOR LOCATIONS: USE ONLY BUILDING WIRE, TYPE THHN/THWN INSULATION, IN RACEWAY. 4. UNDERGROUND LOCATIONS: USE ONLY BUILDING WIRE, TYPE THHN/THWN INSULATION, IN RACEWAY. C. WIRE AND CABLE ROUTING INDICATED IS APPROXIMATE UNLESS DIMENSIONED. INCLUDE WIRE AND CABLE LENGTHS WITHIN 10 FT OF LENGTH SHOWN. D. COMPLETELY AND THOROUGHLY SWAB RACEWAY BEFORE INSTALLING WIRE. E. NEATLY TRAIN AND LACE WIRING INSIDE BOXES, EQUIPMENT, AND PANELBOARDS. F. SPECIAL TECHNIQUES--BUILDING WIRE IN RACEWAY: 1. PULL CONDUCTORS INTO RACEWAY AT SAME TIME. 2. INSTALL BUILDING WIRE 4 AWG AND LARGER WITH PULLING EQUIPMENT. G. SPECIAL TECHNIQUES - CABLE: 1. PROTECT EXPOSED CABLE FROM DAMAGE. 2. SUPPORT CABLES ABOVE ACCESSIBLE CEILING, USING SPRING METAL CLIPS OR CABLE TIES TO SUPPORT CABLES FROM STRUCTURE OR CEILING SUSPENSION SYSTEM. DO NOT REST CABLE ON CEILING PANELS. 3. USE SUITABLE CABLE FITTINGS AND CONNECTORS. H. SPECIAL TECHNIQUES - DIRECT BURIAL CABLE: 1. TRENCH AND BACKFILL FOR DIRECT BURIAL CABLE INSTALLATION. INSTALL WARNING TAPE ALONG ENTIRE LENGTH OF DIRECT BURIAL CABLE, WITHIN 3 INCHES OF GRADE. 2. USE SUITABLE DIRECT BURIAL CABLE FITTINGS AND CONNECTORS. I. SPECIAL TECHNIQUES - WIRING CONNECTIONS: 1. CLEAN CONDUCTOR SURFACES BEFORE INSTALLING LUGS AND CONNECTORS. 2. MAKE SPLICES, TAPS, AND TERMINATIONS TO CARRY FULL AMPACITY OF CONDUCTORS WITH NO PERCEPTIBLE TEMPERATURE RISE. 3. TAPE UNINSULATED CONDUCTORS AND CONNECTORS WITH ELECTRICAL TAPE TO 150 PERCENT OF INSULATION RATING OF CONDUCTOR. 4. INSTALL SPLIT BOLT CONNECTORS OR MULTI-TAP BLOCKS FOR COPPER CONDUCTOR SPLICES AND TAPS, 6 AWG AND LARGER. 5. INSTALL SOLDERLESS PRESSURE CONNECTORS WITH INSULATING COVERS FOR COPPER CONDUCTOR SPLICES AND TAPS, 8 AWG AND SMALLER. 6. INSTALL INSULATED SPRING WIRE CONNECTORS WITH PLASTIC CAPS FOR COPPER CONDUCTOR SPLICES AND TAPS, 10 AWG AND SMALLER. 7. TERMINATE EXISTING ALUMINUM CONDUCTORS WITH TIN-PLATED, ALUMINUM-BODIED COMPRESSION CONNECTORS ONLY. FILL WITH ANTI-OXIDANT COMPOUND BEFORE INSTALLING CONDUCTOR. 8. INSTALL SUITABLE REDUCING CONNECTORS OR MECHANICAL CONNECTOR ADAPTORS FOR CONNECTING ALUMINUM CONDUCTORS TO COPPER CONDUCTORS. J. GROUND CONDUCTORS: 1. FOR 6 AWG AND SMALLER: GREEN. 2. FOR 4 AWG AND LARGER: IDENTIFY WITH GREEN TAPE AT BOTH ENDS AND VISIBLE POINTS INCLUDING JUNCTION BOXES. K. ALL WIRING SHALL BE #12 CU UNLESS SPECIFIED OTHERWISE. ELECTRICAL SPECIFICATIONS A. ALL ELECTRICAL WORK TO CONFORM TO: 1. NFPA 70 (NATIONAL ELECTRIC CODE) - CURRENT VERSION 2. NECA (NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION) - STANDARD OF INSTALLATION 3. NETA ATS (INTERNATIONAL ELECTRICAL TESTING ASSOCIATION) - ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER DISTRIBUTION EQUIPMENT AND SYSTEMS. 4. NFPA 72 (NATIONAL FIRE PROTECTION ASSOCIATION - NATIONAL FIRE ALARM CODE). 5. ALL APPLICABLE LOCAL CODES. B. ALL WORK SHOWN ON THIS DRAWING IS THE RESPONSIBILITY OF THE CONTRACTOR, UNLESS CLEARLY INDICATED AS PART OF ANOTHER PRIME CONTRACT. C. PROVIDE TEMPORARY POWER REQUIRED FOR ALL TRADES. D. MATCH OWNERS EXISTING STANDARD EQUIPMENT. E. COORDINATE WORK TO MINIMIZE OUTAGE DURATION. F. OBTAIN ALL REQUIRED PERMITS & INSPECTIONS. G. PROVIDE FOR ELECTRICAL INSPECTIONS AND SUBMIT REPORTS TO THE OWNER. H. SUBMIT O&M MANUALS TO OWNER UPON COMPLETION OF WORK. I. PROVIDE TRAINING SESSION FOR DESIGNATED MAINTENANCE PERSONNEL. J. PROVIDE SUBMITTALS FOR ALL ELECTRICAL EQUIPMENT, EXCLUDING WIRE, CONDUIT, AND FASTENERS. 1. HANDHOLES. 2. PANELBOARDS - SHOP DRAWINGS (INDICATE OUTLINE AND SUPPORT POINT DIMENSIONS, VOLTAGE, MAIN BUS AMPACITY, INTEGRATED SHORT CIRCUIT AMPERE RATING, CIRCUIT BREAKER AND FUSIBLE SWITCH ARRANGEMENT AND SIZES) AND CATALOG DATA SHOWING SPECIFIED FEATURES OF STANDARD PRODUCTS. 3. ENCLOSED SWITCHES - SWITCH RATINGS AND ENCLOSURE DIMENSIONS. 4. DEVICES - MANUFACTURER'S CATALOG INFORMATION SHOWING DIMENSIONS, COLORS, AND CONFIGURATIONS. 5. LUMINAIRES (INCLUDING EMERGENCY & EXIT FIXTURES) - CATALOG INFORMATION SHOWING DIMENSIONS, RATINGS, AND PERFORMANCE DATA. K. SELECT MATERIALS, SIZES, AND TYPES OF ANCHORS, FASTENERS, AND SUPPORTS TO CARRY LOADS OF EQUIPMENT AND RACEWAY, INCLUDING WEIGHT OF WIRE AND CABLE IN RACEWAY. GROUNDING SYSTEMS A. GROUNDING SYSTEM RESISTANCE: 25 OHMS. B. GROUNDING SYSTEMS: 1. MECHANICAL CONNECTORS: BRONZE CONNECTORS, SUITABLE FOR GROUNDING AND BONDING APPLICATIONS, IN CONFIGURATIONS REQUIRED FOR PARTICULAR INSTALLATION. C. EXOTHERMIC CONNECTIONS: EXOTHERMIC MATERIALS, ACCESSORIES, AND TOOLS FOR PREPARING AND MAKING PERMANENT FIELD CONNECTIONS BETWEEN GROUNDING SYSTEM COMPONENTS. D. WIRE: STRANDED COPPER. E. GROUNDING ELECTRODE CONDUCTOR: SIZE TO MEET NFPA 70 AND LOCAL MUNICIPALITY REQUIREMENTS. F. INSTALLATION: 1. EQUIPMENT GROUNDING CONDUCTOR: INSTALL SEPARATE, INSULATED CONDUCTOR WITHIN EACH FEEDER AND BRANCH CIRCUIT RACEWAY. TERMINATE EACH END ON SUITABLE LUG, BUS, OR BUSHING. 2. DO NOT FASTEN SUPPORTS TO PIPES, DUCTS, MECHANICAL EQUIPMENT, OR CONDUIT. 3. OBTAIN PERMISSION FROM ARCHITECT/ENGINEER BEFORE USING POWDER-ACTUATED ANCHORS OR DRILLING OR CUTTING STRUCTURAL MEMBERS. HANGERS AND SUPPORTS A. ANCHORS & FASTENERS TO BE CORROSION RESISTANT. B. ANCHOR AND FASTEN ELECTRICAL PRODUCTS TO BUILDING ELEMENTS AND FINISHES AS FOLLOWS: 1. CONCRETE STRUCTURAL ELEMENTS: PROVIDE EXPANSION ANCHORS. 2. STEEL STRUCTURAL ELEMENTS: PROVIDE BEAM CLAMPS AND SPRING STEEL CLIPS. 3. CONCRETE SURFACES: PROVIDE EXPANSION ANCHORS. 4. HOLLOW MASONRY, PLASTER, AND GYPSUM BOARD PARTITIONS: PROVIDE TOGGLE BOLTS AND HOLLOW WALL FASTENERS. 5. SOLID MASONRY WALLS: PROVIDE EXPANSION ANCHORS. 6. SHEET METAL: PROVIDE SHEET METAL SCREWS. 7. WOOD ELEMENTS: PROVIDE WOOD SCREWS. C. SUPPORTS: 1. FABRICATE SUPPORTS FROM STRUCTURAL STEEL OR FORMED STEEL MEMBERS. RIGIDLY WELD MEMBERS OR INSTALL HEXAGON HEAD BOLTS TO PRESENT NEAT APPEARANCE WITH ADEQUATE STRENGTH AND RIGIDITY. INSTALL SPRING LOCK WASHERS UNDER NUTS. 2. INSTALL SURFACE MOUNTED CABINETS AND PANELBOARDS WITH MINIMUM OF FOUR ANCHORS. 3. IN WET AND DAMP LOCATIONS INSTALL STEEL CHANNEL SUPPORTS TO STAND CABINETS AND PANELBOARDS 1 INCH OFF WALL. 4. INSTALL SHEET METAL CHANNEL TO BRIDGE STUDS ABOVE AND BELOW CABINETS AND PANELBOARDS RECESSED IN HOLLOW PARTITIONS. EXISTING WORK A. PRIOR TO CONSTRUCTION & INSTALLATION, CONTRACTOR TO VERIFY EXISTING CONDITIONS AND NOTIFY ARCHITECT/ENGINEER OF CONFLICTS OR CONDITIONS WHICH INTERFERE WITH INSTALLATION AS SET FORTH IN CONTRACT DOCUMENTS. B. CONTRACTOR RESPONSIBLE FOR ALL NEW FLOOR OPENINGS, EXCAVATIONS, AND PENETRATIONS,UNLESS SPECIFICALLY NOTED. UNLESS SPECIFICALLY NOTED, UPON COMPLETION, ALL PENETRATIONS TO BE SEALED TO MAINTAIN FIRE RATING AS SPECIFIED ON ARCHITECTURAL DRAWINGS. C. ALL CUTTING AND PATCHING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, UNLESS CLEARLY INDICATED AS PART OF ANOTHER PRIME CONTRACT. D. COORDINATE ANY NEW ROOF PENETRATIONS WITH THE OTHER TRADES. E. REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW CONSTRUCTION. F. REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING DEMOLITION AND EXTENSION WORK. G. MAINTAIN ACCESS TO EXISTING BOXES AND OTHER INSTALLATIONS REMAINING ACTIVE AND REQUIRING ACCESS. MODIFY INSTALLATION OR PROVIDE ACCESS PANEL. H. EXTEND EXISTING RACEWAY AND BOX INSTALLATIONS USING MATERIALS AND METHODS COMPATIBLE WITH EXISTING ELECTRICAL INSTALLATIONS, OR AS SPECIFIED. I. CLEAN AND REPAIR EXISTING COMPONENTS TO REMAIN OR TO BE REINSTALLED. J. PROVIDE ACCESS TO EXISTING WIRING CONNECTIONS REMAINING ACTIVE AND REQUIRING ACCESS. MODIFY INSTALLATION OR INSTALL ACCESS PANEL. K. EXTEND EXISTING CIRCUITS USING MATERIALS AND METHODS COMPATIBLE WITH EXISTING ELECTRICAL INSTALLATIONS, OR AS SPECIFIED. L. RING OUT CIRCUITS IN EXISTING PANEL AFFECTED BY THE WORK. WHERE ADDITIONAL CIRCUITS ARE NEEDED, REUSE CIRCUITS AVAILABLE FOR REUSE. INSTALL NEW BREAKERS. M. TAG UNUSED CIRCUITS AS SPARE AND SWITCH BREAKER TO THE "OFF" POSITION. N. WHERE EXISTING CIRCUITS ARE INDICATED TO BE REUSED, USE SENSING MEASURING DEVICES TO VERIFY CIRCUITS FEEDING PROJECT AREA OR ARE NOT IN USE. O. PROVIDE NEW UPDATED DIRECTORIES WHERE MORE THAN THREE CIRCUITS HAVE BEEN MODIFIED OR REWIRED. P. IDENTIFY SALVAGE ITEMS IN COOPERATION WITH OWNER. REMOVE AND PROTECT ITEMS TO BE SALVAGED AND TURN OVER TO OWNER. Q. CAREFULLY REMOVE EQUIPMENT, MATERIALS, OR FIXTURES WHICH ARE TO BE REUSED. MINOR ELECTRICAL DEMOLITION A. DEMOLITION DRAWINGS ARE BASED ON CASUAL FIELD OBSERVATION AND EXISTING RECORD DOCUMENTS. REPORT DISCREPANCIES TO ARCHITECT/ENGINEER BEFORE DISTURBING EXISTING INSTALLATION. B. CEASE OPERATIONS IMMEDIATELY WHEN STRUCTURE APPEARS TO BE IN DANGER AND NOTIFY ARCHITECT/ENGINEER. DO NOT RESUME OPERATIONS UNTIL DIRECTED. C. VERIFY WIRING AND EQUIPMENT INDICATED TO BE DEMOLISHED SERVE ONLY ABANDONED FACILITIES. D. PROVIDE TEMPORARY EGRESS SIGNAGE AND EMERGENCY LIGHTING. E. DISCONNECT ELECTRICAL SYSTEMS IN WALLS, FLOORS, AND CEILINGS SCHEDULED FOR REMOVAL. REMOVE CONDUIT, WIRE, BOXES, AND FASTENING DEVICES TO AVOID ANY INTERFERENCE WITH NEW INSTALLATION. F. INSTALL TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING CONSTRUCTION. G. REMOVE EXPOSED ABANDONED WIRE, CABLE, CONDUIT, GROUNDING AND BONDING COMPONENTS, FASTENERS AND SUPPORTS, AND ELECTRICAL IDENTIFICATION COMPONENTS, INCLUDING ABANDONED COMPONENTS ABOVE ACCESSIBLE C CEILING FINISHES. CUT EMBEDDED CONDUITS AND SUPPORT ELEMENTS FLUSH WITH WALLS AND FLOORS. PATCH SURFACES DAMAGED BY REMOVAL OF EXISTING COMPONENTS. H. DISCONNECT ABANDONED CIRCUITS AND OUTLETS AND REMOVE ABANDONED RACEWAY, OUTLETS, BOXES, WIRE, AND CABLE INCLUDING ABOVE ACCESSIBLE CEILING FINISHES. CUT RACEWAY FLUSH WITH WALLS AND FLOORS, AND PATCH SURFACES. REMOVE CONCEALED ABANDONED RACEWAY TO ITS SOURCE. I. RECONNECT EQUIPMENT BEING DISTURBED BY RENOVATION WORK AND REQUIRED FOR CONTINUED SERVICE TO NEAREST AVAILABLE PANEL. REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW CONSTRUCTION. J. REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING DEMOLITION AND EXTENSION WORK. K. CLEAN AND REPAIR EXISTING EQUIPMENT TO REMAIN (AFFECTED BY THE SCOPE OF THE PROJECT) OR TO BE REINSTALLED. L. PROTECT AND RETAIN POWER TO EXISTING ACTIVE EQUIPMENT REMAINING. M. CAP ABANDONED EMPTY CONDUIT AT BOTH ENDS AND MARK AS SPARE. FIRE ALARM SYSTEM A. SYSTEM DESCRIPTION: NONCODED ADDRESSABLE SYSTEM, WITH AUTOMATIC SENSITIVITY CONTROL OF CERTAIN SMOKE DETECTORS AND MULTIPLEXED SIGNAL TRANSMISSION, DEDICATED TO FIRE-ALARM SERVICE ONLY. B. SUBMITTALS 1. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. 2. SHOP DRAWINGS: FOR FIRE-ALARM SYSTEM. INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS, AND ATTACHMENTS TO OTHER WORK. C. FIELD QUALITY-CONTROL REPORTS 1. OPERATION AND MAINTENANCE DATA: FOR FIRE-ALARM SYSTEMS AND COMPONENTS TO INCLUDE IN EMERGENCY, OPERATION, AND MAINTENANCE MANUALS. D. INSTALLER QUALIFICATIONS: 1. PERSONNEL SHALL BE TRAINED AND CERTIFIED BY MANUFACTURER FOR INSTALLATION OF UNITS. 2. INSTALLATION SHALL BE BY PERSONNEL CERTIFIED BY NICET AS FIRE-ALARM LEVEL II TECHNICIAN. E. OBTAIN FIRE-ALARM SYSTEM FROM SINGLE SOURCE FROM SINGLE MANUFACTURER. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. F. FIRE-ALARM SIGNAL INITIATION SHALL BE BY ONE OR MORE OF THE FOLLOWING DEVICES: 1. MANUAL STATIONS. 2. HEAT DETECTORS. 3. SMOKE DETECTORS. 4. AUTOMATIC SPRINKLER SYSTEM WATER FLOW. G. CONTINUOUSLY OPERATE ALARM NOTIFICATION APPLIANCES. H. IDENTIFY ALARM AT FIRE-ALARM CONTROL UNIT AND REMOTE ANNUNCIATORS. I. TRANSMIT AN ALARM SIGNAL TO THE REMOTE ALARM RECEIVING STATION J. GENERAL REQUIREMENTS FOR FIRE-ALARM CONTROL UNIT: 1. FIELD-PROGRAMMABLE, MICROPROCESSOR-BASED, MODULAR, POWER-LIMITED DESIGN WITH ELECTRONIC MODULES, COMPLYING WITH UL 864 AND LISTED AND LABELED BY AN NRTL. 2. ADDRESSABLE CONTROL CIRCUITS FOR OPERATION OF MECHANICAL EQUIPMENT. 3. ALPHANUMERIC DISPLAY AND SYSTEM CONTROLS: ARRANGED FOR INTERFACE BETWEEN HUMAN OPERATOR AT FIRE-ALARM CONTROL UNIT AND A ADDRESSABLE SYSTEM COMPONENTS INCLUDING ANNUNCIATION AND SUPERVISION. DISPLAY ALARM, SUPERVISORY, AND COMPONENT STATUS MESSAGES AND THE PROGRAMMING AND CONTROL MENU. 4. KEYPAD: ARRANGED TO PERMIT ENTRY AND EXECUTION OF PROGRAMMING, DISPLAY, AND CONTROL COMMANDS AND TO INDICATE CONTROL COMMANDS TO BE ENTERED INTO THE SYSTEM FOR CONTROL OF SMOKE-DETECTOR SENSITIVITY AND OTHER PARAMETERS. K. ADDRESSABLE INITIATION DEVICES THAT COMMUNICATE DEVICE IDENTITY AND STATUS. L. SMOKE SENSORS SHALL ADDITIONALLY COMMUNICATE SENSITIVITY SETTING AND ALLOW FOR ADJUSTMENT OF SENSITIVITY AT FIRE-ALARM CONTROL UNIT. M. TEMPERATURE SENSORS SHALL ADDITIONALLY TEST FOR AND COMMUNICATE THE SENSITIVITY RANGE OF THE DEVICE. N. ANNUNCIATOR AND DISPLAY: LIQUID-CRYSTAL TYPE, 1 LINE(S) OF 40 CHARACTERS, MINIMUM. O. INITIATING DEVICE, NOTIFICATION APPLIANCE, AND SIGNALING LINE CIRCUITS: NFPA 72, CLASS B. P. AUTOMATICALLY TRANSMIT ALARM, SUPERVISORY, AND TROUBLE SIGNALS TO A REMOTE ALARM STATION. Q. GENERAL REQUIREMENTS FOR MANUAL FIRE-ALARM BOXES: COMPLY WITH UL 38. BOXES SHALL BE FINISHED IN RED WITH MOLDED, RAISED-LETTER OPERATING INSTRUCTIONS IN CONTRASTING COLOR; SHALL SHOW VISIBLE INDICATION OF OPERATION; AND SHALL BE MOUNTED ON RECESSED OUTLET BOX. IF INDICATED AS SURFACE MOUNTED, PROVIDE MANUFACTURER'S SURFACE BACK BOX. R. DOUBLE-ACTION MECHANISM REQUIRING TWO ACTIONS TO INITIATE AN ALARM, PULL-LEVER] TYPE; WITH INTEGRAL ADDRESSABLE MODULE ARRANGED TO COMMUNICATE MANUAL-STATION STATUS (NORMAL, ALARM, OR TROUBLE) TO FIRE-ALARM CONTROL UNIT. S. STATION RESET: KEY- OR WRENCH-OPERATED SWITCH. T. GENERAL REQUIREMENTS FOR SYSTEM SMOKE DETECTORS: 1. INTEGRAL ADDRESSABLE MODULE: ARRANGED TO COMMUNICATE DETECTOR STATUS (NORMAL, ALARM, OR TROUBLE) TO FIRE-ALARM CONTROL UNIT. 2. BASE MOUNTING: DETECTOR AND ASSOCIATED ELECTRONIC COMPONENTS SHALL BE MOUNTED IN A TWIST-LOCK MODULE THAT CONNECTS TO A FIXED BASE. PROVIDE TERMINALS IN THE FIXED BASE FOR CONNECTION TO BUILDING WIRING. 3. SELF-RESTORING: DETECTORS DO NOT REQUIRE RESETTING OR READJUSTMENT AFTER ACTUATION TO RESTORE THEM TO NORMAL OPERATION. 4. INTEGRAL VISUAL-INDICATING LIGHT: LED TYPE INDICATING DETECTOR HAS OPERATED AND POWER-ON STATUS. 5. PHOTOELECTRIC SMOKE DETECTORS: 6. DETECTOR ADDRESS SHALL BE ACCESSIBLE FROM FIRE-ALARM CONTROL UNIT AND SHALL BE ABLE TO IDENTIFY THE DETECTOR'S LOCATION WITHIN THE SYSTEM AND ITS SENSITIVITY SETTING. U. AN OPERATOR AT FIRE-ALARM CONTROL UNIT, HAVING THE DESIGNATED ACCESS LEVEL, SHALL BE ABLE TO MANUALLY ACCESS THE FOLLOWING FOR EACH DETECTOR: 1. PRIMARY STATUS. 2. DEVICE TYPE. 3. PRESENT AVERAGE VALUE. 4. PRESENT SENSITIVITY SELECTED. 5. SENSOR RANGE (NORMAL, DIRTY, ETC.). V. HEAT DETECTORS, GENERAL REQUIREMENTS FOR HEAT DETECTORS: COMPLY WITH UL 521. W. REMOTE ANNUNCIATOR 1. ANNUNCIATOR FUNCTIONS SHALL MATCH THOSE OF FIRE-ALARM CONTROL UNIT FOR ALARM, SUPERVISORY, AND TROUBLE INDICATIONS. MANUAL SWITCHING FUNCTIONS SHALL MATCH THOSE OF FIRE-ALARM CONTROL UNIT, INCLUDING ACKNOWLEDGING, SILENCING, RESETTING, AND TESTING. 2. MOUNTING: FLUSH CABINET, NEMA 250, TYPE 1. 3. DISPLAY TYPE AND FUNCTIONAL PERFORMANCE: ALPHANUMERIC DISPLAY AND LED INDICATING LIGHTS SHALL MATCH THOSE OF FIRE-ALARM CONTROL UNIT. PROVIDE CONTROLS TO ACKNOWLEDGE, SILENCE, RESET, AND TEST FUNCTIONS FOR ALARM, SUPERVISORY, AND TROUBLE SIGNALS. X. EQUIPMENT INSTALLATION 1. COMPLY WITH NFPA 72 FOR INSTALLATION OF FIRE-ALARM EQUIPMENT. 2. INSTALL WALL-MOUNTED EQUIPMENT, WITH TOPS OF CABINETS NOT MORE THAN 72 INCHES (1830 MM) ABOVE THE FINISHED FLOOR. Y. LOCATE DETECTORS NOT CLOSER THAN 3 FEET (1 M) FROM AIR-SUPPLY DIFFUSER OR RETURN-AIR OPENING. Z. LOCATE DETECTORS NOT CLOSER THAN 12 INCHES (300 MM) FROM ANY PART OF A LIGHTING FIXTURE. AA. FIRE-ALARM CONTROL UNIT: SURFACE MOUNTED, WITH TOPS OF CABINETS NOT MORE THAN 72 INCHES (1830 MM) ABOVE THE FINISHED FLOOR. AB. GROUND FIRE-ALARM CONTROL UNIT AND ASSOCIATED CIRCUITS; COMPLY WITH IEEE 1100. INSTALL A GROUND WIRE FROM MAIN SERVICE GROUND TO FIRE-ALARM CONTROL UNIT. AC. ENGAGE A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE TO TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN FIRE-ALARM SYSTEM. RACEWAY AND BOXES A. PROVIDE RACEWAY AND BOXES LOCATED AS INDICATED, AND AT OTHER LOCATIONS REQUIRED FOR SPLICES, TAPS, WIRE PULLING, EQUIPMENT CONNECTIONS, AND COMPLIANCE WITH REGULATORY REQUIREMENTS. RACEWAY AND BOXES ARE SHOWN IN APPROXIMATE LOCATIONS UNLESS DIMENSIONED. PROVIDE RACEWAY TO COMPLETE WIRING SYSTEM. B. UNDERGROUND MORE THAN 5 FEET OUTSIDE FOUNDATION WALL: PROVIDE SCHEDULE 80 PVC. PROVIDE CAST METAL BOXES OR NONMETALLIC HANDHOLES WHERE REQUIRED. C. UNDERGROUND WITHIN 5 FEET FROM FOUNDATION WALL: PROVIDE RIGID STEEL CONDUIT OR THICKWALL NONMETALLIC CONDUIT (SCHEDULE 80 PVC). PROVIDE CAST METAL OR NONMETALLIC BOXES. D. IN OR UNDER SLAB ON GRADE: PROVIDE THICK WALL NONMETALLIC CONDUIT. PROVIDE CAST OR NONMETALLIC METAL BOXES. E. OUTDOOR LOCATIONS, ABOVE GRADE: PROVIDE RIGID STEEL CONDUIT. PROVIDE CAST METAL OR NONMETALLIC OUTLET, PULL, AND JUNCTION BOXES. F. IN SLAB ABOVE GRADE: PROVIDE THICKWALL NONMETALLIC CONDUIT. PROVIDE CAST NONMETALLIC BOXES. G. WET AND DAMP LOCATIONS: PROVIDE THICKWALL NONMETALLIC CONDUIT. PROVIDE CAST METAL OR NONMETALLIC OUTLET, JUNCTION, AND PULL BOXES. PROVIDE FLUSH MOUNTING OUTLET BOX IN FINISHED AREAS. H. CONCEALED DRY LOCATIONS: PROVIDE ELECTRICAL METALLIC TUBING. PROVIDE SHEET-METAL BOXES. PROVIDE FLUSH MOUNTING OUTLET BOX IN FINISHED AREAS. PROVIDE HINGED ENCLOSURE FOR LARGE PULL BOXES. I. MINIMUM RACEWAY SIZE: 3/4 INCH UNLESS OTHERWISE SPECIFIED. J. ARRANGE RACEWAY AND BOXES TO MAINTAIN HEADROOM AND PRESENT NEAT APPEARANCE. GROUP RELATED RACEWAY; SUPPORT USING CONDUIT RACK; PROVIDE SPACE ON EACH FOR 25 PERCENT ADDITIONAL RACEWAYS. K. RACEWAY ROUTING IS SHOWN IN APPROXIMATE LOCATIONS UNLESS DIMENSIONED. ROUTE TO COMPLETE WIRING SYSTEM. L. DO NOT SUPPORT RACEWAY WITH WIRE, PERFORATED PIPE STRAPS, CEILING SUPPORT WIRES OR OTHER PIPING SYSTEMS. M. ROUTE EXPOSED & ABOVE ACCESSIBLE CEILINGS RACEWAY PARALLEL AND PERPENDICULAR TO WALLS. N. DO NOT CROSS CONDUITS IN SLAB. O. INSTALL NO MORE THAN EQUIVALENT OF THREE 90 DEGREE BENDS BETWEEN BOXES. INSTALL CONDUIT BODIES TO MAKE SHARP CHANGES IN DIRECTION, AS AROUND BEAMS. INSTALL FACTORY ELBOWS FOR BENDS IN METAL CONDUIT LARGER THAN 2 INCH SIZE. P. AVOID MOISTURE TRAPS; INSTALL JUNCTION BOX WITH DRAIN FITTING AT LOW POINTS IN CONDUIT SYSTEM. Q. INSTALL FITTINGS TO ACCOMMODATE EXPANSION AND DEFLECTION WHERE RACEWAY CROSSES SEISMIC, CONTROL AND EXPANSION JOINTS. R. INSTALL SUITABLE PULL STRING OR CORD IN EACH EMPTY RACEWAY EXCEPT SLEEVES AND NIPPLES. S. CLOSE ENDS AND UNUSED OPENINGS IN WIREWAY. T. INSTALL PULL BOXES AND JUNCTION BOXES ABOVE ACCESSIBLE CEILINGS AND IN UNFINISHED AREAS ONLY. U. IN ACCESSIBLE CEILING AREAS: INSTALL OUTLET AND JUNCTION BOXES NO MORE THAN 6 INCHES FROM CEILING ACCESS PANEL OR FROM REMOVABLE RECESSED LUMINAIRE. V. LOCATE FLUSH MOUNTING BOX IN MASONRY WALL TO REQUIRE CUTTING OF MASONRY UNIT CORNER ONLY. COORDINATE MASONRY CUTTING TO ACHIEVE NEAT OPENING. W. DO NOT INSTALL FLUSH MOUNTING BOX BACK-TO-BACK IN WALLS; INSTALL WITH MINIMUM 6 INCHES SEPARATION. INSTALL WITH MINIMUM 24 INCHES SEPARATION IN ACOUSTIC RATED WALLS. X. DO NOT FASTEN BOXES TO CEILING SUPPORT WIRES OR OTHER PIPING SYSTEMS. Y. SUPPORT BOXES INDEPENDENTLY OF CONDUIT. Z. USE FLUSH MOUNTING OUTLET BOX IN FINISHED AREAS. AA. SET FLOOR BOXES LEVEL AND FLUSH WITH FINISH FLOORING MATERIAL AB. INSTALL CONDUIT TO PRESERVE FIRE RESISTANCE RATING OF PARTITIONS AND OTHER ELEMENTS. AC. ROUTE CONDUIT THROUGH ROOF OPENINGS FOR PIPING AND DUCTWORK OR THROUGH SUITABLE ROOF JACK WITH PITCH POCKET. AD. ALIGN ADJACENT WALL MOUNTED OUTLET BOXES FOR SWITCHES, THERMOSTATS, AND SIMILAR DEVICES. WALL PLATES A. MANUFACTURERS: 1. PASS & SEYMOUR LEGRAND. 2. TAYMAC 20510 (WEATHERPROOF-IN-USE). 3. HUBELL (BELL/RACO). 4. LEVITON. 5. GENERAL ELECTRIC. B. INSTALL DECORATIVE PLATES ON SWITCH, RECEPTACLE, AND BLANK OUTLETS IN FINISHED AREAS. DECORATIVE COVER PLATE: NYLON. C. INSTALL JUMBO SIZE PLATES FOR OUTLETS INSTALLED IN MASONRY WALLS. JUMBO COVER PLATE: NYLON. D. WEATHERPROOF COVER PLATE (RECEPTACLE): IMPACT RESISTANT PLASTIC PLATE WITH HINGED AND GASKETED DEVICE COVER. COVER TO BE RATED FOR WET LOCATION WHILE IN USE, AND TO BE LOCKABLE. E. WEATHERPROOF COVER PLATE (SWITCH): GASKETED CAST METAL PLATE WITH HINGED AND GASKETED DEVICE COVER OR LEVER SWITCH MECHANISM. (P&S CA-31G/HUBBELL/BELL/RACO 5125 OR EQUAL) F. KITCHEN AREAS: 302/430 STAINLESS STEEL, WEATHERPROOF FOR STARTUPS. G. INSTALL GALVANIZED (STAMPED) STEEL PLATES ON OUTLET BOXES AND JUNCTION BOXES IN UNFINISHED AREAS, ABOVE ACCESSIBLE CEILINGS, AND ON SURFACE MOUNTED OUTLETS. H. INSTALL DEVICES PLUMB AND LEVEL. I. INSTALL SWITCHES WITH OFF POSITION DOWN. J. INSTALL RECEPTACLES WITH GROUNDING POLE ON TOP, OR TO THE LEFT (IF MOUNTED HORIZONTALLY. K. CONNECT WIRING DEVICE GROUNDING TERMINAL TO OUTLET BOX WITH BONDING JUMPER AND BRANCH CIRCUIT EQUIPMENT GROUNDING CONDUCTOR. L. CONNECT WIRING DEVICES BY WRAPPING SOLID CONDUCTOR AROUND SCREW TERMINAL. INSTALL STRANDED CONDUCTOR FOR BRANCH CIRCUITS 10 AWG AND SMALLER. WHEN STRANDED CONDUCTORS ARE USED IN LIEU OF SOLID, USE CRIMP ON FORK TERMINALS FOR DEVICE TERMINATIONS. DO NOT PLACE BARE STRANDED CONDUCTORS DIRECTLY UNDER DEVICE SCREWS. M. ADJUST DEVICES AND WALL PLATES TO BE FLUSH AND LEVEL.CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER SOUTH BAKER SOUTH RFD KITCHEN RENOVATION E001 12309492 ELECTRICAL NOTES, SYMBOL LEGEND, & ABBREVIATIONS R. HEARD MPS 3004S APRIL 15, 2020 1 02/14/2020 ISSUE FOR 100% SD REVIEW 2 03/24/2020 ISSUE FOR 95% REVIEW 3 04/10/2020 ISSUE FOR COORDINATED REVIEW 4 04/15/2020 ISSUE FOR CONSTRUCTION JJ J Ref DW J DD 3 3 F GENERAL DRAWING NOTES: CONTRACTOR TO TRACE OUT EXISTING CIRCUITS AND UPDATE PANEL SCHEDULES ACCORDINGLY. ELECTRICAL CONTRACTOR RESPONSIBLE FOR COMPLETING A PANEL WALK DOWN FOR EACH PANEL BEING AFFECTED FOR THIS PROJECT TO DETERMINE REQUIREMENTS AND COORDINATE SHUTDOWNS. UNLESS OTHERWISE NOTED, EXISTING CONDITIONS ARE SHOWN IN GRAYSCALED, DEMOLITION WORK IS SHOWN IN BOLD AND DASHED, PROJECT WORK SHOWN IN BOLD. PROVIDE NEW WORK AS SHOWN. PROVIDE ARC FAULT PROTECTION FOR ALL CIRCUITS IN ACCORDANCE WITH NEC ARTICLE 210.12 (A) & (B). EXPOSED CONDUIT IS NOT ACCEPTABLE. PROVIDE WIREMOLD WHERE EXPOSED/SURFACE WIRING IS REQUIRED. A. B. C. D. E. REMOVE EXISTING THREE-WAY SWITCH. WIRING TO BE RE-WORKED TO FUNCTION AS SINGLE POLE SWITCH TO CONTROL LIGHTS IN ENTRYWAY. REMOVE EXISTING THREE-WAY AND WIRING SAVE BOX LOCATION IF FEASEABLE TO RELOCATE DINING AREA SWITCHES. REMOVE FAN SWITCH AND WIRING TO CLEAR AREA. SAVE WIRING TO EXTEND TO NEW FAN HOOD. REMOVE EXISTING DEVICE/FIXTURE SAVE LOCATION AND WIRING TO PROVIDE NEW DEVICE/FIXTURE. REMOVE EXISTING DINING AREA DIMMER SWITCHES AND RE-WORK WIRING TO NEW LOCATION AS INDICATED, SWITCHES TO BE REPLACED WITH ON/OFF SWITCHES. REMOVE DEVICE/FIXTURE AND WIRING TO CLEAR AREA. REMOVE DEVICE/FIXTURE AND WIRING TO CLEAR AREA. 1 DEMOLITION KEYED NOTES: TYPICAL ALL SHEETS," KEYNOTES ARE COMMON FOR ALL SHEETS" EACH KEYNOTE MAY NOT APPEAR IN PLANS ON EVERY SHEET. 2 3 4 5 6 7 EXTEND WIRING AND CONNECT NEW LIGHT FIXTURES AND SWITCHING TO EXISTING CIRCUIT. EXTEND WIRING AND MODIFY SWITCHING AS REQUIRED. EXTEND WIRING AND CONNECT NEW RECEPTACLES TO EXISTING CIRCUITS. UNLESS OTHERWISE NOTED, MOUNT ABOVE COUNTER. EXTEND WIRING AND CONNECT NEW FIRE ALARM DEVICES TO EXISTING WIRING. EXTEND WIRING AND CONNECT NEW HOOD FAN TO EXISTING CIRCUIT. EXTEND WIRING AND CONNECT NEW DISHWASHER TO EXISTING CIRCUIT. EXTEND WIRING AND CONNECT NEW RANGE UNIT TO EXISTING CIRCUIT. EXTEND WIRING AND CONNECT NEW RECEPTACLES TO EXISTING CIRCUITS. UNLESS OTHERWISE NOTED, MOUNT ABOVE COUNTER. REFRIDGERATOR AND MICROWAVE TO BE ON DEDICATED CIRCUITS. 1 2 KEYED NOTES: TYPICAL ALL SHEETS," KEYNOTES ARE COMMON FOR ALL SHEETS" EACH KEYNOTE MAY NOT APPEAR IN PLANS ON EVERY SHEET. 3 4 5 6 7 +44 AFF GFI +66 AFF MCW HOOD FAN B B A A A A +44 AFF GFI +66 AFF MCW HOOD FAN B B UC GFI A A A A A AA D EXISTING CIRCUIT CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER SOUTH BAKER SOUTH RFD KITCHEN RENOVATION E101 12309492 ELECTRICAL REMOVAL AND POWER PLAN R. HEARD MPS 3004S APRIL 15, 2020 1/2" = 1'-0"E101 1 ELECTRICAL REMOVAL PLAN NN 0'2'4'8'0'2'4'8' 1 4 4 4 4 3 2 44 664 5 4 4 4 4 4 7 6 4 LIGHT FIXTURE SCHEDULE TYPE LAMP DESCRIPTION MANUFACTURER MODEL # MOUNTING COMMENTS A LED RECESSED CAN HALO #HLBSL4069FS351EMW RECESSED B LED UNDER CABINET LIGHT COLOR KINETICS CAT#523-000027-96 120-000065-00 108-000035-00 WALL/CABINET 1/2" = 1'-0"E101 2 POWER PLAN 1 1 1 1 1 1 1 1 2 22 2 2 2 4 7 6 2 5 2 1 33 1 7 1 1 02/14/2020 ISSUE FOR 100% SD REVIEW 2 03/24/2020 ISSUE FOR 95% REVIEW 3 04/10/2020 ISSUE FOR COORDINATED REVIEW 4 04/15/2020 ISSUE FOR CONSTRUCTION