Loading...
HomeMy WebLinkAboutGuthrie - Landscape DD SET 2020-02-28NOTE: IMPROVEMENTS INCLUDED AS PART OF GMG PROJECT & RELATED PLANS. AGREED UPON IMPROVEMENTS BOUNDARY BETWEEN CITY HARBOR AND GUTHRIE MEDICAL GROUP, - SEE CIVIL PLANS. BP S01 S01 S01 L01 L02-2 L02-2 L02-2 L02-2 L02-2 L02-2 L02 L02 L02 L02 S01 L02 L02-3 L01 L01 L02-2 L01 L01 BP PAV01 F04 F04 PAV01 L02-2 L01 L01 L01 PAV04 PAV02 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 PAV04 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 PAV03-2 S01 S01 S01 S01 S01 S01 F04 F04 F04 PAV04 S01 L02-3 S02 S02 S02 S02 L01 F09 F09 L02-3 L02-3 L02-2 L02 L02-2 L02-2 L02-2 L02 S01 PAV02 PAV02 PAV02 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 S01 BP PAV01 PAV01 PAV01 PAV01 PAV01 PAV01 PAV01 PAV01 PAV01 PAV01 PAV01 S01 PAV01 PAV01 L02 L02-3 BP S01 S01 S01 S01 S01 L03 L03 L03 L03 F11 F11 F11 F11 F11 F11 F11 F11 F11 F11 F12 F12 F12PAV01 L03 S01 S01 PAV03-2 F04 F04 GUTHRIE MEDICAL GROUP AT CITY HARBOR SITE MATERIALS PLAN & SCHEDULE -GMG DATE:2/28/2020 DWG NO: L100 SCALE: 1"=20'-0" REVISION - DATE 02/14/20 100% CD SET N NOTE: IMPROVEMENTS INCLUDED AS PART OF GMG PROJECT & RELATED PLANS. AGREED UPON IMPROVEMENTS BOUNDARY BETWEEN CITY HARBOR AND GUTHRIE MEDICAL GROUP, - SEE CIVIL PLANS. GUTHRIE MEDICAL GROUP AT CITY HARBOR (1) MP (1) MS (1) MS (3) CO (1) AC (2) VS (2) CF (1) AC (3) VP (2) SP (4) IV (1) MS (2) JS (2) VP (3) HQ (3) SP (5) CL (1) MS (3) JV (3) FG (3) CXO (3) HQ (2) SP (3) FG (3) MS (1) QB (3) IV (2) MS (1) JV (5) CL (2) SP (3) QR (3) PO (2) SB (3) MS (2) QR (3) AR (2) VP (3) HQ (3) MP (300)CP (300) CP (400)CP (150) AG (120) AG (150) AG (300)PD (200)PD (150) PD (500)EP (300)EP SOD (1) QR (2) MP (1) MP (2) VS (3) FG(1) AF (1) AF (2) AF (2) TXT (2) TXT (2) MP (2) IV (3) IV (3) FG (3) FG (2) CXP (6) CXP (1) QR (1) QR (3) CXP (3) JS (2) JS (2) JS(2) JS (2) MP (1) CL (3) MP (2) MP (1) CL (2) CL (3) MP (2) MP (1) SB (3) PV (3) PV (3) CL (2) HQ (3) CL (2) VP (3) PV (3) PV (1) MS (3) IV (2) VP (2) JS (3) QB (3) FG (3) FG (3) PV (1) QB (3) MP (1) JV (2) MP EXISTING TREE (2) IV (2) JS (1) MS (3) VP (3) HQ (3) CXP (2) HQ (2) JS (3) CV (4) HQ (3) JV (5) CL (2) CL (2) JV (4) HQ (2) JV (4) VS (3) CL (2) JV (2) CL (2) JV (3) VP (800) CP (500) EP (125) CP (100) EP (60) PD (150)EP (40)CP (25) PD (70) EP (100) PD (700) PD (200)EP (50)PD (100) PD (250) PD (600) EP (350) CP (150) CP (450) CP (250)AG (450)EP (400) PD (40)PD (650) CP (250) PD (600) CP (100) AG (30) AG (850) EP (250) CP (220) PD (1000) EP (150) PD (200) PD (400)EP (30) PD (50) PD (140) AG (700) EP (150) AG (350) CP (450) CP (4) VS (1) QB (1) QB (3) VP (8) VS (3) CXP (3) CXP (3) QB (3) HQ (90) CP (1) MS (3) CXP(2) JS (3) VP (25) PD (3) IV (3) MP (1000) PD (150) PD (6) IV (5) TXT (300) CP (180) PD (300) EP (5) QB (5) AC (3) GT (1) QR (2) CV (1) CV (5) CS (3) MP (3) CV (1) CV (5) CL (1) MP (3) MP (3) MP(2) CL (2) MP (3) CV (1) CL (2) CL (5) BP (5) BN (3) QR (1) QR (1) QR (1) PO (1) PO (2) PO (5) AR (7) AR (5) CV (3) VS (7) AR (1) SB (2) AC (1) BP (5) IV (1) SP (5) SP (4) SP (5) CS (2) CO (1) CO (1) BN (1) BN (5) IV (1) BN (3) SP (2) SP (4) CS (3) MP (5) CS (2) MP (1) BP (1) BP (3) CS (2) CS (1) BP (1) BN (2) CXP (3) CL (2) MS (1) CL (2) SP (400) CP (120) CP (150) PD (400)PD (300) EP (550)CP (250) PD (150)CP (350) EP EXISTING TREE EXISTING TREE (1) PO (4) PO (1) VS (1) QB (1) QB (1) QB (1) QB (1) PO (1) QB (1) QB (5) QP (3) PO (3) SB (2) BN (2) BN (2) BN (1) BP (1) BP (1) BP (1) BP (1) BP (3) BP (1) BP (1) BP (1) BP (7) CS (1) CS (2) CS (15) LS (10) PE (15) EP (15) LS (15)LS (10) PE (10) PE (15) EP (15) EP (15) EP (15) EP (15) LS (15) LS (10)PE (10) PE (15) LS (10)PE (10)PE (15) EP (15)EP (15) LS (15) LS (500) PD EXISTING TREE EXISTING TREE (1) PO (1) BN SITE PLANTING PLAN & SCHEDULE -GMG DATE:2/28/2020 DWG NO: L200 SCALE: 1"=20'-0" REVISION - DATE 02/14/20 100% CD SET N 3"-4" DOUBLEGROUND HARDWOODMULCH COVERED AND WEED-FREEUNTIL INSTALLATION (NATURAL. UNDYED)SEE PLANTING PLAN FOR PLANT TYPETOPSOIL COMPOST 50/50 BOUNDDEPTH AS SPECIFIED IN MATERIALSSCHEDULECOMPACTED SUBGRADE,95% STANDARD PROCTORGEO-TEXTILECONCRETE PAVINGSEE CIVIL DRAWINGSNOTES:1. LOOSEN ROOTS IF ROOT BOUND2. FINISHED SURFACE OF THE MULCH SHOULDBE 1" BELOW GRADE OF PAVINGCOMPACTED SUBGRADE,95% STANDARD PROCTORCONCRETE PAVINGSEE CIVIL DRAWINGS3"-4" DOUBLEGROUND HARDWOODMULCH COVERED AND WEED-FREEUNTIL INSTALLATION (NATURAL UNDYED),DO NOT PLACE MULCH IN CONTACT WITHTRUNK.SEE PLANTING PLAN FOR PLANT TYPETOPSOIL COMPOST 50/50BOUND DEPTH AS SPECIFIEDIN MATERIALS SCHEDULEGEO-TEXTILEBOTTOM OF ROOT BALL RESTSON UNDISTURBED SOIL2 TIMES THEROOTBALLDIAMETERNOTES:1. REMOVE ALL TWINE AND ROPE, WIRE ORBURLAP FOR TOP HALF OF ROOT BALL2. LOOSEN ROOTS IF ROOT BOUND3. ROOT CROWN AT FINISHED GRADE TO 1"ABOVE GRADE- SEE CIVIL DRAWINGSCOMPACTED SUBGRADE,95% STANDARD PROCTORCURB FOUNDATION TO EXTEND NO MORETHAN 3" TOWARD ROOT BALL. MIN. 8" SOILBETWEEN CURB FOUNDATION AND ROOTBALLSTREET TREES AS IDENTIFIED ONPLANTING PLAN TO BE PLANTEDON CENTER IN TREE PITPLANTINGS AS SHOWN INLANDSCAPE PLAN2 TIMES THEROOTBALLDIAMETERNOTES:1. ENSURE THAT SOIL FILLS WIDTH OF TRENCH, SHORE UPSIDES AS NECESSARY TO PREVENT GRAVEL INTRUSION.2. EACH TREE TO HAVE MINIMUM PLANTING SOIL VOLUME760 CU FT PER CITY SITE ORDINANCE 276-7 PROJECTREVIEW CRITERIA B.3.C. LARGE TO MEDIUM CANOPYTREES3. SEE DETAIL #3 FOR TREE STAKING REQUIREMENTS4. SEE DETAIL #1 FOR TREE PLANTING REQUIREMENTS5. STRUCTURAL SOIL IN AREA AS NEEDED, SEE MATERIALSPLANS.CU STRUCTURAL SOIL ™OR APPROVED EQUAL ASNEEDED- SEE MATERIALS PLANSDRAINAGE PIPE TO STORMSEWERAS NEEDED - SEE CIVILDRAWINGSTYP. CURB- SEE CIVIL DRAWINGSSIDEWALK / ROADWAY- SEE CIVIL DRAWINGSTAMP SOIL AROUND ROOT BALLBASE FIRMLY WITH FOOT PRESSURE TO PREVENT SHIFT1:1 SLOPE ON SIDESOF PLANTING HOLENOTES:1. DO NOT HEAVILY PRUNE THE TREE AT PLANTING. PRUNEONLY CROSSOVER LIMBS, CO-DOMINANT LEADERS, ANDBROKEN OR DEAD BRANCHES. SOME INTERIOR TWIGS ANDLATERAL BRANCHES MAY BE PRUNED; HOWEVER, DO NOTREMOVE THE TERMINAL BUDS OF BRANCHES THAT EXTENDTO THE EDGE OF THE CROWN.2. EACH TREE TO HAVE MINIMUM PLANTING SOIL VOLUME 760CU FT PER CITY SITE ORDINANCE 276-7 PROJECT REVIEWCRITERIA B.3.C. LARGE TO MEDIUM CANOPY TREES3. STAKE TREES ONLY UPON THE APPROVAL OF THELANDSCAPE ARCHITECT4. REMOVE ALL TWINE, ROPE, WIRE AND BURLAP FROM TOPHALF OF ROOT BALL5. IF PLANT IS SHIPPED WITH A WIRE BASKET AROUND THEROOT BALL, CUT THE WIRE BASKET IN FOUR PLACES ANDFOLD DOWN 8" INTO PLANTING HOLE6. ROOT CROWN ABOVE FINISHED GRADE BY 1"-2"BOTTOM OF ROOT BALL RESTSON UNDISTURBED SOIL2 TIMES THEROOTBALLDIAMETER3"-4" DOUBLEGROUND HARDWOODMULCH COVERED AND WEED-FREEUNTIL INSTALLATION (NATURAL. UNDYED)DO NOT PLACE MULCH IN CONTACT WITHTRUNKTOPSOIL COMPOST 50/50 BOUNDDEPTH AS SPECIFIED IN MATERIALSSCHEDULECONCRETE PAVINGSEE CIVIL DRAWINGSGEO-TEXTILECOMPACTED SUBGRADE,95% STANDARD PROCTORDEPTH OFROOTBALLTREE PLANTING HOLEDEPTH OF ROOTBALLEACH TREE MUST BE PLANTED SUCHTHAT THE TRUNK FLARE IS VISIBLE ATTHE TOP OF THE ROOT BALL. TREESWHERE THE TRUNK FLARE IS NOTVISIBLE SHALL BE REJECTED. DO NOTCOVER THE TOP OF THE ROOT BALLWITH SOIL.6'-0"1'-0"PLANVIEW18" - 30"NOTES:1. REMOVE ANY DAMAGED OR BROKEN BRANCHES2. REMOVE NURSERY STAKE. IF CENTRAL LEADERNEEDS TO BE STRAIGHTENED OR HELD ERECT,IT IS ACCEPTABLE TO ATTACH A 12" X 8' BAMBOOPOLE TO THE CENTRAL LEADER AND TRUNK FORA MAXIMUM OF 12 MONTHS.3. SEE DETAIL#6 FOR TREE PLANTING DEATILCOMPACTED SUBGRADE,95% STANDARD PROCTOR2 TIMES THEROOTBALLDIAMETERNONABRASIVE NYLON WEBBING +GROMMETTHREE (2") TWO-INCH LODGE POLE STAKESDRIVE STAKE INTO SUBGRADE 6"-12". INSTALLAPPX. 2" AWAY FROM EDGE OF ROOT BALL.STAKE LOCATION SHALL NOT INTERFERE WITHPERMANENT BRANCHES. REMOVE 6 MONTHSAFTER PLANTING UNLESS OTHERWISEDIRECTED BY LANDSCAPE ARCHITECT.NONABRASIVE NYLON WEBBING +GROMMETLODGE POLE STAKESPREVAILING WINDNOTES:1. BEAVER PROTECTION BARRIER TO BEAPPLIED TO TREES WITHIN THEPROMENADE, RESTAURANT DROP-OFFZONE, AND PADDLE PARK.2. REPLACE WIRE IF IT BECOMES CORRODEDOR IF MORE ROOM IS NEEDED FORADDITIONAL TREE TRUNK GROWTH.3. SEE DETAIL #6 FOR TREE PLANTINGREQUIREMENTS4. MESH DOES NOT NEED TO BE BURIEDUNDERGROUNDBLACK, VINYL COATED WELDEDWIRE MESHNO LARGER THAN 1.5"-2"MESH TO BE AT LEAST 3' TALLATTACH MESH TO ITSELF WITHBLACK 12 1/2 GAUGE PVCCOATED HOG RINGS. SECURE INPLACE WITH HOG RING PLIERS.3'-0"CONDITION VARIES,SEE MATERIALS PLAN.ALL BIORETENTIONDRAINAGE DETAILS- SEE CIVIL DRAWINGS 1'5" 6" 2'1'BIORETENTION SOIL,- SEE CIVIL SPECS.MULCH- SEE TYP. TREE PLANTING DETAILCOMPACTED SUBGRADE,95% STANDARD PROCTORTREES AND PLANTINGS AS IDENTIFIEDON PLANTING PLANCURB- SEE CIVIL DRAWINGS AND LOT LAYOUTNOTES:1. SEE DETAIL #5 FOR TREE STAKINGREQUIREMENTS2. SEE DETAIL #6 FOR TREE PLANTINGREQUIREMENTSSEE MATERIAL PLANS& CIVIL DRAWINGSSEE MATERIAL PLANS& CIVIL DRAWINGSGEO-TEXTILEEDGES BUTTED TIGHTLYCOMPACTED SUBGRADE,95% STANDARD PROCTOR1" OR 2"TOPSOIL COMPOST50/50 BOUNDTOP VIEWFILL LARGE GAP WITHTOPSOIL & SEED IF NECESSARYNOTES:1. SOD TO BE SATURATED DAILY FORMINIMUM 10 DAYS AFTER INSTALLATION2. AFTER FIRST 10 DAYS, WATER ONCE AWEEK FOR MINIMUM 1 MONTH.PERENNIAL PLANTING DETAIL1SCALE: 1/2" = 1'-0"SHRUB PLANTING DETAIL2SCALE:1/2" = 1'-0"STREET TREE PLANTING DETAIL3SCALE: 1/2" = 1'-0"STAKING DETAIL5SCALE: 1/2" = 1'-0"TREE PLANTING DETAIL6SCALE: 1/2" = 1'-0"DWG NO:PLANTINGDETAILSDATE:2/27/2020L300SCALE: AS SHOWNREVISION - DATENBEAVER PROTECTION DETAIL4SCALE: 1/2" = 1'-0"BIORETENTION PLANTING8SCALE: 1/2" = 1'-0"SOD DETAILSCALE: 3/4" = 1'-0"7 NOTES:1. THE FIXTURES ARE TO BE MOUNTED ON THEFOUNDATIONS SHOWN IN THIS DRAWING.2. SEE MANUFACTURE INSTALLATION INSTRUCTION FORFINAL CONCRETE FOOTING DEPTH.FINISHED GRADESOIL PER PLANTING PLAN(4) 3/4" x 10" GALVANIZED STEEL ANCHOR BOLTSWITH NUTS AND WASHER- SEE MANUFACTURE SPECIFICATIONS.PRECAST CONCRETE FOOTINGDEPTH TO BE CONFIRMED WITH ENGINEER.1" DIA. PVC CONDUITPROVIDE 6" SAND ABOVE AND BELOW CABLE1/2"X8' COPPERWELD GROUND ROD, CONNECTTO GROUND LUG IN POLE WITH #6 COPPER WIRECOMPACTED SUBGRADE, 95% STANDARD PROCTOR2'-0"4' MIN 1 1/2" MIN1 3/4" MAX 1'-6" SETBACKFROM SIDEWALK3/4" - 10 X 17" X 3"THREADED J HOOK- SEE MANUFACTURESPECIFICATIONS.TOP VIEW6" AGGREGATE BACKFILL IF REQUIRED6" MIN FRONT ELEVATIONSIDE ELEVATIONF04 - ANOVA 'MADISON'THERMORY CONTOUR BENCH- SEE MATERIALS PLANS.PAV01 - SEE MATERIALS PLANSAND CIVIL ENGINEERING DETAILS.3/8"-16 X 1-1/8"SS BUTTONHEAD CAP SCREW WITH3/8" SS OR RUBBER WASHER- SEE MANUFACTURERSPECIFICATIONS3/8" DROP-IN ANCHOR- SEE MANUFACTURERSPECIFICATIONS11 GAUGE STEEL TUBINGBOLT WITH WASHERAND DROP IN ANCHOR-SEE MANUFACTURER SPECIFICATIONSTOP VIEWTOP VIEWSIDE VIEWMOUNTINGFRONT VIEWF09 - ANOVA 'MADISON'35 GAL THERMORY RECEPTACLE- SEE MATERIALS PLANS.PAV01 - SEE MATERIALS PLANSAND CIVIL ENGINEERING DETAILS.3/8" X 5" 18-8 STAINLESSSTEEL STUD ANCHORSWITH (2) 3/8" RUBBER WASHERS- SEE MANUFACTURERSPECIFICATIONSDETAILSDATE:2/27/2020DWG NO: L400SCALE: AS SHOWNREVISION - DATENTRASH RECEPTACLE3SCALE: 3/4" = 1'-0"LIGHT POST4SCALE: 3/4" = 1'-0"PICNIC TABLE5SCALE: 1/2" = 1'-0"BIKE RACK1BENCH SWING6SCALE: 1/2" = 1'-0"SCALE: 1" = 1'-0"NOTES:1. THESE DETAILS WERE PREPARED USING MANUFACTURE DETAILS SPECIFIED; IN CASE OF ANYDISCREPANCY, DEFER TO MANUFACTURE SEPCIFICATIONS & NOTIFY LANDSCAPE ARCHITECTS.BENCH2SCALE: 3/4" = 1'-0"