Loading...
HomeMy WebLinkAboutLF ADD 1_5-6-2020ABBREVIATIONS:&AND@ATAASSOCIATEACALTERNATING CURRENT/ACOUSTICALA/CAIR CONDITIONINGACMASBESTOS CONTAINING MATERIALACTACOUSTICAL CEILING TILEADAREA DRAINADJADJUSTABLE/ADJACENTAFACCESS FLOORAFFABOVE FINISH FLOORALTALTERNATEALUMALUMINUMAMPAMPEREANODANODIZEDAPACCESS PANELAPPDAPPROVEDARCHARCHITECT/ARCHITECTURALASPHASPHALTASYMASYMMETRICALAVBAIR & VAPOR BARRIERAVGAVERAGEBBBUILDING BOARDBDBOARDBLDGBUILDINGBLKGBLOCKINGBMBEAM/BENCH MARKB.O.BY OTHERSBRKBRICKBSMTBASEMENTBTMBOTTOMBTWBETWEENBURBUILT UP ROOFINGBVLBEVELCABCABINETC.C.CENTER TO CENTERCERCERAMICCFMCUBIC FEET PER MINUTECJCONTROL JOINTCLCLOSERCLGCEILINGCLRCLEARCMUCONCRETE MASONRY UNITC.O.CASED OPENINGCOL(S)COLUMN(S)COMMCOMMUNICATIONCONCCONCRETECONDCONDUITCONFCONFERENCECONNCONNECTION(S)CONSTRCONSTRUCTIONCONTCONTINUOUSCOORDCOORDINATECORRCORRIDORCPCIRCUIT PANELCPTCARPETCRCOLD ROLLEDCRSCOURSE(S)CSOCASED OPENINGCTCERAMIC TILECTAICOOLING TOWER AIR INTAKECTRCENTERCUCUBICCWCOLD WATERCYCOPYDDEEP/DEPTHDBLDOUBLEDCDIRECT CURRENTDEMODEMOLITIONDETDETAILDFDRINKING FOUNTAINDIADIAMETER/DIAGONALDIMDIMENSIONDISPDISPENSERDLDEAD LOADDNDOWNDODOOR OPENINGDRDOORDWGDRAWINGEEAST(E)EXISTING TO REMAINEAEACHECEMPTY CONDUITEECEXISTING EXPOSED CONSTRUCTIONEFEXHAUST FANEIFSEXTERIOR INSULATION FINISH SYSTEMELELEVATION(S)ELECELECTRICALELEVELEVATOREMEMERGENCYEMTELECTRICAL METALLIC TUBINGENCLENCLOSUREEQEQUAL(ER)EXIST. TO BE REMOVED(ERR)EXIST. TO BE REMOVED & RELOCATEDEWCELECTRICAL WATER COOLEREXHEXHAUSTEXIST,EXEXISTINGEXP BTEXPANSION BOLTEXP JTEXPANSION JOINTEXTEXTERIORFFILEFAFIRE ALARMFDFLOOR DRAINFEFIRE EXTINGUISHERFECFIRE EXTINGUISHER CABINETFHCFIRE HOSE CABINETFINFINISHFIXTFIXTUREFLRFLOORFLUORFLUORESCENTF.O.FACE OFFPFIRE PROOFFPSCFIRE PROOF SELF CLOSINGFPBFIRE PULL BOXFRFRAMEFSPFIRE STANDPIPEFTFOOTFTGFOOTINGFWCFABRIC WALL COVERINGGAGAUGEGALVGALVANIZEDGBLKGYPSUM BLOCKGCGENERAL CONTRACTORGFIGROUND FAULT INTERRUPTERGLGLASSGR,GDGRADEGWBGYPSUM WALLBOARDGYPGYPSUMHBHOSE BIBBHCHANDICAPPEDHMHOLLOW METALHDWHARDWAREHDWDHARDWOODHORIZHORIZONTALHPHIGH POINTHPLHIGH PRESSURE LAMINATEHRHOURHTHEIGHTHTGHEATINGHVACHEATING, VENTILATION, AIR CONDITIONINGHVPHIGH VOLTAGE PANELHWHOT WATERIBCINSTALL BY CONTRACTORIBOINSTALL BY OWNERIDINSIDE DIAMETERINCLINCLUDE/INCLUDINGINSULINSULATIONINTINTERIORJBOXJUNCTION BOXJSJAMB SWITCHJTJOINTKWKILOWATTLACLACQUERLAMLAMINATELAVLAVATORYLBSPOUNDSLFLINEAR FEETLHLEFT HANDLHRBLEFT HAND RETURN BEVELLLLIVE LOADLSCLOCKSET CYLINDRICALLSMLOCKSET MORTISEDLDLINEAR DIFFUSERLTLIGHTLVLOUVERLVPLOW VOLTAGE PANELMAGMAGNETICMARBMARBLEMASMASONRYMAXMAXIMUMMCMAIL CHUTEMEZZMEZZANINEMFRMANUFACTURERMINMINIMUMMISCMISCELLANEOUSMLDGMOLDINGM.O.MASONRY OPENINGMOD-BITMODIFIED BITUMINOUS ROOFINGMPMEASURE POINT / MASONRY PAINTMTDMOUNTEDMTLMETALMULMULLIONNNORTH/NEWNATNATURALNECNEW EXPOSED CONSTRUCTIONNICNOT IN CONTRACTNONUMBERNOMNOMINALNRNOISE REDUCTIONNRCNOISE REDUCTION COEFFICIENTNTSNOT TO SCALEOCON CENTERODOUTSIDE DIAMETEROHOPPOSITE HANDOPPOPPOSITEPARTPARTITIONPCPLPORTLAND CEMENT PLASTERPGLPLATE GLASSPBOPROVIDED BY OWNERPLFPOUNDS PER LINEAR FOOTPLAMPLASTIC LAMINATEPLASPLASTERPSIPOUNDS PER SQUARE INCHPTPAINTPTDPAINTEDPTGPAINTINGPTDRPAPER TOWEL DISPENSERPTRPAPER TOWEL RECEPTACLEPVCPOLYVINYL CHLORIDEPWDPLYWOODR/ARETURN AIRRADRADIUSRBRUBBER BASERDROOF DRAIN(RE)RELOCATED EXISTINGRCPREFLECTED CEILING PLANREFREFRIGERATORREINREINFORCING/REINFORCEDREQDREQUIREDRHRIGHT HANDRHRBRIGHT HAND REVERSE BEVELRMROOMROROUGH OPENINGRUBRUBBERSSOUTH/SUPPLYSAFBSOUND ATTENUATION FIRE BATTSBSTRAIGHT BASESCSEPARATE CIRCUIT/SELF CLOSINGSCHSCHEDULESEALSEALANTSIMSIMILARSLCSOLID CORESNDSANITARY NAPKIN DISPOSALSNVSANITARY NAPKIN VENDORSPECSPECIFICATIONSQSQUARESSSTAINLESS STEELSTDSTANDARDSTLSTEELSTNSTAINSTRUCTSTRUCTURESUBSUBSTITUTESUSPSUSPENDEDSVCSERVICESYMSYMMETRICALSYSSYSTEMTBTOWEL BARTBDTO BE DETERMINEDTDTRENCH DRAINTELTELEPHONETGLTEMPERED GLASST&GTONGUE & GROOVETHTHRESHOLDTHRUTHROUGHTHKTHICK/THICKNESSTLTILET.O.TOP OFT.O.S.TOP OF SLABTPDTOILET PAPER DISPENSERTSTILE STARTTYPTYPICALU.O.N.UNLESS OTHERWISE NOTEDVVOLTVBVINYL BASEVCTVINYL COMPOSITE TILEVERTVERTICALVIFVERIFY IN FIELDVNRVENEERV. PLASVENEER PLASTERVTVINYL TILEWWEST/WATTW/WITHWCWATER CLOSETWDWOODWFWIDE FLANGEWPWATER PROOFWRWASTE RECEPTACLEWSWET STACKWWFWELDED WIRE FABRICWWMWELDED WIRE MESHYDYARDPROPERTY LINEEXISTING EXTERIOR WALL TO REMAINEXISTING INTERIOR PARTITION TO REMAINEXISTING CONSTRUCTION TO BE DEMOLISHEDNEW WALL WITH NO REQUIRED FIRE RATINGNEW WALL WITH REQUIRED 2-HOUR FIRE RATINGWALL LEGEND:SYMBOLS:KEYNOTEDETAILSECTIONELEVATIONSVERTICAL ELEVATIONPARTITION TYPEROOM NAME & NUMBERDOOR NUMBERWINDOW NUMBERREVISION NUMBERCENTERLINEALIGN SURFACESEQUAL DIMENSIONSGYPSUM BOARDWOODRIGID INSULATIONBATT INSULATION101A-00101X'-X"FINISH FL.A-00101A-0012413(TYPE) 000 CLALIGNEQ.EQ.ROOM NAMEROOM #DOOR #WINDOW #(FIRE RATING IN HOURS)00ROOM #REFLECTED CEILING PLAN LEGEND:HVAC SUPPLY DIFFUSERHVAC RETURN GRILLESUSPENDED DOWNLIGHT FIXTURELINEAR DOWNLIGHT FIXTURESUSPENDED LINEAR LIGHT FIXTUREUNDER CABINET LIGHT FIXTURERECESSED LINEAR LIGHT FIXTURECEILING-MOUNTED OCCUPANCY SENSORCEILING-MOUNTED PHOTO SENSORMOTOR LOCATIONEXHAUST INLETSINGLE POLE SWITCH - 48" AFF U.O.N.DIMMER (SWITCH) OR CONTROL - 48" AFF U.O.N.CEILING MOUNTED CORD REELCARBON MONOXIDE DETECTORABCDEOCPSSSDGENERAL NOTES:1.CONSTRUCTION SHALL BE ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, & LOCAL LAWS AND ORDINANCES.2.CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE RULES, REGULATIONS, AND INSTRUCTIONS OF THE OWNER.3.DIMENSIONS AND LOCATIONS OF WORK SHALL BE DETERMINED BY WRITTEN DIMENSIONS ONLY. DIMENSIONS ARE TAKEN TO FINISH SURFACES OF GWB, INSIDE SURFACE OF GLASS, CENTERLINES OF STEEL, AND THE INSIDE EDGE OF NOMINAL DOOR OPENINGS, UNLESS OTHERWISE INDICATED. NOTIFY ARCHITECT OF ANY DISCREPANCIES. CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD PRIOR TO THE START OF WORK.4.THE SITE SHALL BE KEPT CLEAR OF DEBRIS AND IN ORDER AT ALL TIMES. REFUSE TO BE REMOVED DAILY.5.ANY FIREPROOFING OR PROTECTION SYSTEMS IN EXISTING BUILDING DISTURBED BY WORK SHALL BE REPAIRED AND/OR MAINTAINED TO PROVIDE THE EXISTING RATING OR DEGREE OF PROTECTION (UNLESS OTHERWISE NOTED).6.ALL SERVICES AND UTILITIES WHICH SERVE ACTIVE FACILITIES SHALL NOT BE INTERRUPTED. INCLUDING BUT NOT LIMITED TO: FIRE PROTECTION, WATER, AND ELECTRICAL. COORDINATE SWITCHOVERS WITH OWNER. CONFIRM IN WRITING SCHEDULING AT LEAST 72 HOURS IN ADVANCE OF EVERY ACTIVE SHUT DOWN OR SWITCHOVER.7.FOR REQUIRED PROJECT SCHEDULE. SEE THE PROJECT MANUAL.LOCATION OF WORKLOADING DOCKDUMPSTER LOCATION 1PARKING SPOT LIMITED TO 10 YARDS OR LESSDUMPSTER LOCATION 2COORDINATE WITH EXISTING IN-GROUND TANKRevisions:347 West 36 Street Suite 1501New York, NY 10018212-245-5195 T212-239-7130 FKey Plan:Notes:Grumman HallCornell UniversityIthaca, NY 14850Richard McElhiney Architects LLCMay 6, 2020Issue for Bid April 2, 2020Scale:31 Knight StreetNorwalk, CT 06851203-866-5538 T203-866-5243 FAltieri Sebor Wieber LLC303 South Broadway, Suite G20Tarrytown, NY 10591914-333-1110 T914-333-1109 FJacobs Consultancy4588 South Park AvenueBlasdell, NY 14219716-823-0006 TTrophy PointAREA OF WORK4592 Jordan RoadSkaneateles Falls, NY 13153315-685-4732 TRyan Biggs Clark Davis Engineering & SurveyingFirst and Second Floor Renovation Phase 1As indicatedSymbols, Abbreviations & NotesT-102CAMPUS LOCATOR PLANN.T.S.Addendum 1 May 6, 202011 00112233445566778899AABBDDCCEEFF16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"12' - 0"9' - 0"27' - 0"1' - 9"100TD87100TC93OPEN TO BELOW1' - 9"1' - 7"1' - 6"SHAFT1004855118710118999191151193257188A439188495111111122222345OPEN TO BELOWOPEN TO BELOW172900OPEN TO BELOW78888162111111111341661821162182A3381842281861001818319191919100717410066DEMOLITION KEYNOTES:DEMOLISH CONCRETE BLOCK WALL, INCLUDING BRICK WALL BASE, UP TO STRUCTURE. PATCH AND REPAIR ADJACENT BLOCK WALL, FLOOR AND CEILING SURFACES TO REMAIN.DEMOLISH DOOR AND FRAME.DEMOLISH FINISH TILE FLOORING.EXISTING DRAIN PIPE TO REMAIN.EXISTING PIPES TO REMAIN.DEMOLISH WATER TANK. (SEE MECHANICAL DRAWINGS)DEMOLISH ABANDONED ELECTRICAL BOX & CONDUIT.DEMOLISH WINDOW TREATMENT.DEMOLISH EXISTING A.C.T. CEILING, GRID AND SUPPORTS.DEMOLISH EXISTING LIGHT FIXTURES. (SEE ELECTRICAL DRAWINGS)REMOVE EXISTING CONSTRUCTION IN WINDOW AND RESTORE OPERABLE WINDOW FUNCTION.NOT USED.DEMOLISH EXISTING SAFETY SHOWER AND ASSOCIATED PIPING.NOT USED.NOT USED.DEMOLISH DOOR FRAME AND WALL ABOVE UP TO STRUCTURE. PATCH AND REPAIR ADJACENT BLOCK WALL, FLOOR AND CEILING SURFACES TO REMAIN.DEMOLISH CEILING AND WALL MOUNTED ACOUSTICAL PANELS.EXISTING FLOOR DRAIN TO REMAIN.REMOVE RADIATOR COVERS. CLEAN RADIATOR AND STRAIGHTEN FINS. SALVAGE COVERS FOR REPAINTING & REUSE.12345678910111213141516171819EXISTING DOOR AND FRAME TO REMAINEXISTING DOOR AND FRAME TO BE DEMOLISHEDEXISTING WALL CONSTRUCTION TO BE DEMOLISHEDEXISTING WALL CONSTRUCTION TO REMAINGENERAL SYMBOL KEYOUTSIDE SCOPE OF WORK, UNLESS OTHERWISE NOTEDGENERAL FLOOR PREPARATION NOTES:1. THE EXISTING FINISH FLOOR HAS BEEN REMOVED BY THE OWNER.2. THE CONTRACTOR SHALL REMOVE ALL EXISTING MASTICS AND ADHESIVE FROM THE EXISTING SURFACE AS REQUIRED FOR PROPER INSTALLATION OF THE NEW FLOORING AND FLOOR PREPARATION.3. REMOVE EXISTING LOOSE AND DAMAGED FLOOR LEVELING COMPOUND FROM THE FLOOR SLAB, REQUIRED FOR THE INSTALLATION OF NEW FLOOR LEVELING COMPOUND.4. THE CONTRACTOR SHALL REMOVE ALL EXISTING METAL INSERTS, CUT OFF PIPES, AND OTHER IMPEDIMENTS TO A SMOOTH FLOOR SURFACE, AND PATCH ALL HOLES.5. REFER TO THE SPECIFICATIONS FOR FLOOR LEVELING REQUIREMENTS.6. THE CONTRACTOR SHALL INCLUDE THE FOLLOWING ALLOWANCES FOR ADDITIONAL FLOOR PREPARATIONS TO ADDRESS EXISTING CONDITIONS:A. LUMP SUM ALLOWANCE: INCLUDE THE SUM OF 10 LOCATIONS TO REMOVE PIPING AND PATCH FLOOR PENETRATIONS WHERE PIPING IS REMOVED TO PROVIDE FIRE-RATED CONSTRUCTION.B. LUMP SUM ALLOWANCE: INCLUDE SUM OF 30 LOCATIONS TO REMOVE PIPING FASTENERS AND/OR APPURTENANCES.C. LUMP SUM ALLOWANCE: INCLUDE SUM OF 200 SQUARE FEET OF 1/2" LEVELING COMPOUND TO ADDRESS EXISTING FLOORING CONDITIONS AND PROVIDE ADDITIONAL FLOOR PREPARATION AS REQUIRED TO MEET THE SPECIFICATION FOR NEW FINISH FLOOR INSTALLATION.Revisions:347 West 36 Street Suite 1501New York, NY 10018212-245-5195 T212-239-7130 FKey Plan:Notes:Grumman HallCornell UniversityIthaca, NY 14850Richard McElhiney Architects LLCMay 6, 2020Issue for Bid April 2, 2020Scale:31 Knight StreetNorwalk, CT 06851203-866-5538 T203-866-5243 FAltieri Sebor Wieber LLC303 South Broadway, Suite G20Tarrytown, NY 10591914-333-1110 T914-333-1109 FJacobs Consultancy4588 South Park AvenueBlasdell, NY 14219716-823-0006 TTrophy PointAREA OF WORK4592 Jordan RoadSkaneateles Falls, NY 13153315-685-4732 TRyan Biggs Clark Davis Engineering & SurveyingFirst and Second Floor Renovation Phase 11/4" = 1'-0"First Floor Demolition PlanDA-1021/4" = 1'-0"1DEMOLITION FIRST FLOOR PLANPHOTO DETAIL A -EXISTING CONDITIONS (N.T.S.)PHOTO DETAIL B -EXISTING CONDITIONS (N.T.S.)PHOTO DETAIL C -EXISTING CONDITIONS (N.T.S.)Addendum 1 May 6, 2020111 REF.GLASS MARKERBOARD.NEW INTERIOR WINDOW.NEW STAINLESS STEEL CORNER GUARD.EXISTING FLOOR DRAIN TO REMAIN.(SEE PLUMBING PLANS)EXISTING DRAIN PIPE TO REMAIN.NEW 2'x3' FIRE RATED ACCESS PANEL.REINSTALL REPAINTED RADIATOR COVERS.WALL-MOUNTED COAT HOOK RACK, STAINLESS STEEL TYPE 304, MIN. 6 HOOKS PER RACK (BASIS OF DESIGN WEBI)NEW UNDERCABINET REFRIGERATOR. (BY OWNER)NEW MICROWAVE. (BY OWNER)NEW ROOM SIGNAGE.NEW FLAMMABLE STORAGE CABINET.NEW CORROSIVE STORAGE CABINET.NEW CAULK AT WINDOW SILL TO MATCH ADJACENT.NEW FIRE EXTINGUISHER AND SURFACE-MOUNTED CABINET. VERIFY FINAL LOCATION IN FIELD.11121314151617181920CONSTRUCTION KEYNOTES:NEW BASE CABINETS AND COUNTERTOP. NEW WALL SHELVES.NEW SINK.NEW FUME HOOD.INFILL EXISTING OPENING IN CONCRETE SLAB WITH NEW CONCRETE. (SEE STRUCTURAL DRAWINGS)NEW SAFETY SHOWER WITH EYEWASH.NEW GLASS PARTITION SYSTEM.NEW FINISH FLOOR (SEE FINISH SCHEDULE).NEW MANUAL DUAL ROLLER WINDOW SHADES WITH FASCIA (TYP.)NEW DEIONIZED WATER POLYETHYLENE STORAGE TANK (SEE MECHANICAL PLANS)12345678910212223242500112233445566778899AABBDDCCEEFF16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"12' - 0"9' - 0"27' - 0"1' - 9"100TD87100TC93OPEN TO BELOW1' - 9"1' - 7"1' - 6"SHAFT10048551181 LAB I597182 SADAF'SLAB754184 STUDENTSPACE56318710118999191151193257188A439188495A-3011243A-3021243A-3031243A-30412432' - 0"9' - 6"8' - 0"182A PRINTROOM761234A0B2A0B2B2A01821182A1184118811811A0A0A0A0A0A0A01234566A0132A0OPEN TO BELOW88888172900100CA199996100UA1B2A0A0A011111112100CACOMMONAREA44211111313131313182A11841184218436' - 4"6' - 4"141415151' - 0"100UA6131313133' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"2' - 9"1310A-5019A-50111A-50110A-5019A-50111A-50110A-5016' - 0"3' - 0"3' - 0"ALIGNALIGN4"ALIGN4"ALIGN5' - 9 1/2"1616NOTE:SEE A-142 FOR FURNITURE AND EQUIPMENT LAYOUT.17171717131313EXISTING FUME HOOD1819208A-5012121212121212121212112"18"60" MIN.48" MIN.ADA CLEARANCE (SHOWN DASHED)ADA CLEARANCE (SHOWN DASHED)1007174100662223222324135' - 6"252525EXISTING DOOR AND FRAME TO REMAINNEW DOOR AND FRAMENEW WALL WITH REQUIRED 2-HOUR FIRE RATINGEXISTING WALL CONSTRUCTION TO REMAINGENERAL SYMBOL KEYOUTSIDE SCOPE OF WORK, UNLESS OTHERWISE NOTEDINDICATES CASEWORK OR MILLWORKXXNEW WALL WITH NO REQUIRED FIRE RATINGRevisions:347 West 36 Street Suite 1501New York, NY 10018212-245-5195 T212-239-7130 FKey Plan:Notes:Grumman HallCornell UniversityIthaca, NY 14850Richard McElhiney Architects LLCMay 6, 2020Issue for Bid April 2, 2020Scale:31 Knight StreetNorwalk, CT 06851203-866-5538 T203-866-5243 FAltieri Sebor Wieber LLC303 South Broadway, Suite G20Tarrytown, NY 10591914-333-1110 T914-333-1109 FJacobs Consultancy4588 South Park AvenueBlasdell, NY 14219716-823-0006 TTrophy PointAREA OF WORK4592 Jordan RoadSkaneateles Falls, NY 13153315-685-4732 TRyan Biggs Clark Davis Engineering & SurveyingFirst and Second Floor Renovation Phase 11/4" = 1'-0"First Floor Construction PlanA-1021/4" = 1'-0"1CONSTRUCTION FIRST FLOOR PLANAddendum 1May 6, 2020111111 FSSVSSSSLOCLOCLOCPCFSFSFSFSFSPAPAPASLOCCOCOFSLCRLCRLCRLCRPAMMTHTTTTTT00112233445566778899AABBDDCCEEFF182 SADAF'SLAB754181 LAB I597184 STUDENTSPACE563188495188A43919325719115118999187101100TD87100TC93SHAFT182A PRINTROOM7616' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"12' - 0"9' - 0"27' - 0"17290010048551AA2232DDDDDDDDDD445555555566TYP. TYP.6TYP.6TYP.6TYP.6TYP.888878100CACOMMONAREA442CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCBBBEEEEEEEEEEEEE8787874100UA6+ 8' - 0"+ 8' - 0"8' - 0"4' - 0"4' - 0"8' - 0"8' - 0"4' - 0"4' - 0"8' - 0"8' - 0"4' - 0"4' - 0"8' - 0"+ 10' - 6"+ 11' - 10"+ 10' - 6"+ 11' - 10"+ 10' - 6"+ 11' - 10"+ 11' - 10"+ 11' - 10"+ 10' - 6"+ 11' - 10"EQEQEQEQ100717410066REFLECTED CEILING PLAN KEYNOTES:INFILL EXISTING OPENING IN CONCRETE SLAB WITH NEW CONCRETE. (SEE STRUCTURAL DRAWINGS)UNDER CABINET LIGHTING.PROVIDE NON-UV LIGHT FIXTURES.NEW 2'x2' A.C.T. CEILING.PAINT EXISTING CEILING SLAB AND ALL CEILING MOUNTED PIPES AND DUCTWORK. (TYPICAL)ACOUSTICAL FOAM PANELS ADHERED TO CEILING.SEE A-603 MATERIAL SCHEDULE.METHANE GAS, COMPRESSED AIR, AND GAS TANK DROPS TO TABLE. (SEE PLUMBING DRAWINGS)CONNECTION FOR FUME HOOD EXTRACTOR ARM OR HOOD EXHAUST.GENERAL NOTE:1. EXISTING AND/OR NEW MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION ELEMENTS ARE SHOWN FOR COORDINATION ONLY. REFER TO MEP & FP DRAWINGS FOR SCOPE OF WORK.12345678REFLECTED CEILING PLAN LEGEND:HVAC SUPPLY DIFFUSERHVAC RETURN GRILLESUSPENDED DOWNLIGHT FIXTURELINEAR DOWNLIGHT FIXTURESUSPENDED LINEAR LIGHT FIXTUREUNDER CABINET LIGHT FIXTURERECESSED LINEAR LIGHT FIXTURECEILING-MOUNTED OCCUPANCY SENSORCEILING-MOUNTED PHOTO SENSORMOTOR LOCATIONEXHAUST INLETSINGLE POLE SWITCH - 48" AFF U.O.N.DIMMER (SWITCH) OR CONTROL - 48" AFF U.O.N.CEILING MOUNTED CORD REELCARBON MONOXIDE DETECTORABCDEOCPSSSDEXISTING DOOR AND FRAME TO REMAINNEW DOOR AND FRAMENEW WALL WITH REQUIRED 2-HOUR FIRE RATINGEXISTING WALL CONSTRUCTION TO REMAINGENERAL SYMBOL KEYOUTSIDE SCOPE OF WORK, UNLESS OTHERWISE NOTEDINDICATES CASEWORK OR MILLWORKXXNEW WALL WITH NO REQUIRED FIRE RATINGREFLECTED CEILING PLAN LINEWORK LEGEND:GENERAL EXHAUST DUCTWORKLAB EXHAUST DUCTWORKSUPPLY AIR DUCTWORKRETURN AIR DUCTWORKFIRE PROTECTION PIPINGMETHANE GAS PIPINGKRYPTON GAS PIPINGHOT WATER PIPINGCOLD WATER PIPINGSANITARY WASTE PIPINGSANITARY VENT PIPINGCOMPRESSED AIR PIPINGACID WASTE PIPINGGENERAL NOTE:1. EXISTING AND/OR NEW MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION ELEMENTS ARE SHOWN FOR COORDINATION ONLY. REFER TO MEP & FP DRAWINGS FOR SCOPE OF WORK.Revisions:347 West 36 Street Suite 1501New York, NY 10018212-245-5195 T212-239-7130 FKey Plan:Notes:Grumman HallCornell UniversityIthaca, NY 14850Richard McElhiney Architects LLCMay 6, 2020Issue for Bid April 2, 2020Scale:31 Knight StreetNorwalk, CT 06851203-866-5538 T203-866-5243 FAltieri Sebor Wieber LLC303 South Broadway, Suite G20Tarrytown, NY 10591914-333-1110 T914-333-1109 FJacobs Consultancy4588 South Park AvenueBlasdell, NY 14219716-823-0006 TTrophy PointAREA OF WORK4592 Jordan RoadSkaneateles Falls, NY 13153315-685-4732 TRyan Biggs Clark Davis Engineering & SurveyingFirst and Second Floor Renovation Phase 11/4" = 1'-0"First Floor Reflected Ceiling PlanA-1121/4" = 1'-0"1FIRST FLOOR REFLECTED CEILING PLANAddendum 1 May 6, 202011 LOCSKDLOCFPCPALCRT00112233445566778899AABBDDCCEEFFROOF289 STUDENTWORKSTATIONS48028289628151120023177OTBROOF16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"12' - 0"9' - 0"27' - 0"5655283113200T158282A136286A51286387288729290437294452200C829TYP.6TYP.CCCCCCCCCC+ 10' - 5"+ 9' - 2"+ 10' - 5"+ 9' - 2"+ 10' - 5"20064200452007174REFLECTED CEILING PLAN KEYNOTES:INFILL EXISTING OPENING IN CONCRETE SLAB WITH NEW CONCRETE. (SEE STRUCTURAL DRAWINGS)UNDER CABINET LIGHTING.PROVIDE NON-UV LIGHT FIXTURES.NEW 2'x2' A.C.T. CEILING.PAINT EXISTING CEILING SLAB AND ALL CEILING MOUNTED PIPES AND DUCTWORK. (TYPICAL)ACOUSTICAL FOAM PANELS ADHERED TO CEILING.SEE A-603 MATERIAL SCHEDULE.METHANE GAS, COMPRESSED AIR, AND GAS TANK DROPS TO TABLE. (SEE PLUMBING DRAWINGS)CONNECTION FOR FUME HOOD EXTRACTOR ARM OR HOOD EXHAUST.GENERAL NOTE:1. EXISTING AND/OR NEW MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION ELEMENTS ARE SHOWN FOR COORDINATION ONLY. REFER TO MEP & FP DRAWINGS FOR SCOPE OF WORK.12345678REFLECTED CEILING PLAN LEGEND:HVAC SUPPLY DIFFUSERHVAC RETURN GRILLESUSPENDED DOWNLIGHT FIXTURELINEAR DOWNLIGHT FIXTURESUSPENDED LINEAR LIGHT FIXTUREUNDER CABINET LIGHT FIXTURERECESSED LINEAR LIGHT FIXTURECEILING-MOUNTED OCCUPANCY SENSORCEILING-MOUNTED PHOTO SENSORMOTOR LOCATIONEXHAUST INLETSINGLE POLE SWITCH - 48" AFF U.O.N.DIMMER (SWITCH) OR CONTROL - 48" AFF U.O.N.CEILING MOUNTED CORD REELCARBON MONOXIDE DETECTORABCDEOCPSSSDEXISTING DOOR AND FRAME TO REMAINNEW DOOR AND FRAMENEW WALL WITH REQUIRED 2-HOUR FIRE RATINGEXISTING WALL CONSTRUCTION TO REMAINGENERAL SYMBOL KEYOUTSIDE SCOPE OF WORK, UNLESS OTHERWISE NOTEDINDICATES CASEWORK OR MILLWORKXXNEW WALL WITH NO REQUIRED FIRE RATINGREFLECTED CEILING PLAN LINEWORK LEGEND:GENERAL EXHAUST DUCTWORKLAB EXHAUST DUCTWORKSUPPLY AIR DUCTWORKRETURN AIR DUCTWORKFIRE PROTECTION PIPINGMETHANE GAS PIPINGKRYPTON GAS PIPINGHOT WATER PIPINGCOLD WATER PIPINGSANITARY WASTE PIPINGSANITARY VENT PIPINGCOMPRESSED AIR PIPINGACID WASTE PIPINGGENERAL NOTE:1. EXISTING AND/OR NEW MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION ELEMENTS ARE SHOWN FOR COORDINATION ONLY. REFER TO MEP & FP DRAWINGS FOR SCOPE OF WORK.Revisions:347 West 36 Street Suite 1501New York, NY 10018212-245-5195 T212-239-7130 FKey Plan:Notes:Grumman HallCornell UniversityIthaca, NY 14850Richard McElhiney Architects LLCMay 6, 2020Issue for Bid April 2, 2020Scale:31 Knight StreetNorwalk, CT 06851203-866-5538 T203-866-5243 FAltieri Sebor Wieber LLC303 South Broadway, Suite G20Tarrytown, NY 10591914-333-1110 T914-333-1109 FJacobs Consultancy4588 South Park AvenueBlasdell, NY 14219716-823-0006 TTrophy PointAREA OF WORK4592 Jordan RoadSkaneateles Falls, NY 13153315-685-4732 TRyan Biggs Clark Davis Engineering & SurveyingFirst and Second Floor Renovation Phase 11/4" = 1'-0"Second Floor Reflected CeilingPlanA-1131/4" = 1'-0"1SECOND FLOOR REFLECTED CEILING PLANAddendum 1 May 6, 202011 PFPF PFREF.REF.0123456789ABDCEF16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"12' - 0"9' - 0"27' - 0"1' - 9"100TD87100TC93OPEN TO BELOW1' - 9"1' - 7"1' - 6"SHAFT100717410048181 LAB I597182 SADAF'SLAB754184 STUDENTSPACE56318710118999191151193257188A439188495RES-1RES-1RES-1OPEN TO BELOWCPT-1RES-1100CACOMMONAREA442182A PRINTROOM76RES-2RES-2100660123456789ABDCEF16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"12' - 0"9' - 0"27' - 0"294452290437288729286387286A51282A136282896281511200C8291' - 9"1' - 9"1' - 7"1' - 6"283113200T15820023OTB20071ROOF289 STUDENTWORKSTATIONS480CPT-1JOHNSONITE HARMONIUM XF SHEET LINOLEUM FLOORING AND 4" RUBBER BASE. (COLOR T.B.D.)JOHNSONITE HARMONIUM XF SHEET LINOLEUM FLOORING AND 4" RUBBER BASE. (COLOR T.B.D.)CARPET FLOORING WITH 4" RUBBER BASE. (COLOR T.B.D.)NOTE:PROVIDE ALL REQUIRED FLOOR FINISH ACCESSORIES, INCLUDING TRANSITIONS TO EXISTING OR NEW FLOOR FINISHES OR DIFFERENT MATERIAL.FLOORING LEGEND:RES-1RES-2CPT-10123456789ABDCEF182 SADAF'SLAB754181 LAB I597184 STUDENTSPACE563188495188A43919325719115118999187101100TD87100TC93SHAFT182A PRINTROOM7617290010048551AADDDDDDDDDD100CACOMMONAREA442CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCBBBEEEEEEEEEEEEE100UA66' - 0"5' - 0"5' - 0"6' - 0"6' - 0"5' - 0"5' - 0"6' - 0"6' - 0"5' - 0"5' - 0"6' - 0"EQEQEQEQ100717410066EQ16' - 0"EQEQ16' - 0"EQEQ16' - 0"EQACOUSTICAL FOAM PANELS, 2'x4', 2" THICKNESS.MATERIAL:OPEN-CELL MELAMINE FOAM CORE.FIRE RESISTANCE:CLASS 1 PER ASTME 84, MEETS UL 1715.NRC:80INSTALLATION:ADHERE TO CEILING WITH WATER-BASED ADHESIVE RECOMMENDED BY THE MANUFACTURER.PRODUCT:SONEX CLASSIC ACOUSTICAL FOAM PANEL BY ACOUSTICAL SOLUTIONS (OR APPROVED EQUAL)LEGEND:Revisions:347 West 36 Street Suite 1501New York, NY 10018212-245-5195 T212-239-7130 FKey Plan:Notes:Grumman HallCornell UniversityIthaca, NY 14850Richard McElhiney Architects LLCMay 6, 2020Issue for Bid April 2, 2020Scale:31 Knight StreetNorwalk, CT 06851203-866-5538 T203-866-5243 FAltieri Sebor Wieber LLC303 South Broadway, Suite G20Tarrytown, NY 10591914-333-1110 T914-333-1109 FJacobs Consultancy4588 South Park AvenueBlasdell, NY 14219716-823-0006 TTrophy PointAREA OF WORK4592 Jordan RoadSkaneateles Falls, NY 13153315-685-4732 TRyan Biggs Clark Davis Engineering & SurveyingFirst and Second Floor Renovation Phase 1As indicatedFirst and Second Floor FinishPlansA-1211/8" = 1'-0"2FIRST FLOOR FINISH PLAN1/8" = 1'-0"1SECOND FLOOR FINISH PLANAddendum 1 May 6, 2020111/8" = 1'-0"3FIRST FLOOR REFLECTED CEILING PLAN SHOWING ACOUSITCAL CEILING PANELS1 REF.4S44SVSKDSSSS4JJJSJSLOCK44444TCPJVAVJ-HCHC-LCRLCRLCRMMMMMLCRLCRMMJJ00112233445566778899AABBDDCCEEFF16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"12' - 0"9' - 0"27' - 0"1' - 9"EX. PIPES100TD87100TC93OPEN TO BELOW1' - 9"1' - 7"1' - 6"SHAFT100717410048FHFHFHFHFH181 LAB I597182 SADAF'SLAB754184 STUDENTSPACE56318710118999191151193257188A439188495OPEN TO BELOW121971718112293620201012142326N.I.C.N.I.C.NOTE:DESKS & CHAIRS SHALL BE PROVIDED AND INSTALLED BY OWNER. WIRING OF WORKSTATIONS SHALL BE DONE BY CONTRACTOR.100CACOMMONAREA442182A PRINTROOM7615156A-502113211625EXISTING FUME HOODACACACACACAC12"18"60" MIN.48" MIN.ADA CLEARANCE (SHOWN DASHED)ADA CLEARANCE (SHOWN DASHED)10066N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.RM. ITEM # EQUIPMENT NAME QUANTITY PRODUCT MANUFACTURER / MODEL NEW - FURNISHED NEW - FURNISHED EXISTING INSTALLED BYBY OWNER BY CONTRACTOR REUSED CONTRACTOR1 DEBIND & SINTERING COMBINED FURNACE 1 ADMATEC Y N2 CERAMIC PRINTER 1 ADMATEC - ADMAFLEX 130 Y N3 THERMAL PROPERTY ANALYZER 1 C-THERM - TRIDENT Y N4 PORTABLE DENSITY/SPECIFIC GRAVITY METER 1 ANTON PAAR - DMA 35 Y N5NOT USED -- ----6 FUME EXTRACTOR ARM & CEILING BRACKET 2/4 MOVEX - ME100 Y N7 3D PRINTER 1 FORMLABS - FORM 2 PRINTER Y N8 POROUS FOAMS 1 ULTRAMET, LITHOZ Y N9 GC / MS 1 THERMO ELECTRON CORPORATIONDSQ II MASS SPECTROMETER &YNK27300000000080 GAS CHROMATOGRAPH10 VACUUM PUMP 1 T.B.D. (FUTURE)YN11 FUME HOOD 1 LABCONCO - 5' Y N12 FIXED LAB BENCH W/ CABINETS, SHELVES & SINK 1 MOTT Y N13 GAS CYLINDER CABINET 1 AIRGAS LAB 1000 SERIES (SEE PLUMB. DRAWINGS) Y Y14 SAFETY SHOWER AND EYEWASH 1 BRADLEYYY15 SUSPENDED UTILITY SHELF 2 MOTT Y N16 CANOPY HOOD 1 SEE MECHANICAL DRAWINGS Y Y17 OPTICAL TABLE 1 NEWPORT RS 2000YN18 OPTICAL TABLE 1 T.B.D. (EXISTING)YN19 LAB BENCH (2' x 6') 1 MOTT Y N20 LAB BENCH (3' x 5') 2 MOTT Y N21 CYLINDER RACK AND VALVE 1 UNISTRUT CORP Y N22 FUME HOOD 1 LABCONCO - 5' Y N23 FIXED LAB BENCH W/ CABINETS, SHELVES & SINK 1 MOTT Y N24 LAB BENCH 4 MOTT Y N25 SAFETY SHOWER & EYEWASH 1 BRADLEYYY26 SAFETY SHOWER & EYEWASH 1 BRADLEYYY27 NOT USEDNOTE: ALSO REFER TO SPECIFICATIONS SECTION 011100 SUMMARY OF WORK: PART 1.4.A, SCHEDULE OF OWNER FURNISHED ITEMS.SADAF'S LABLAB IEQUIPMENT SCHEDULE188POWER & COMMUNICATIONS SYMBOLS LEGEND:AUTOMATIC DOOR CONTROLSINGLE CONVENIENCE RECEPTACLE - 16" AFF U.O.N.DUPLEX CONVENIENCE RECEPTACLE - 16" AFF U.O.N.DOUBLE DUPLEX CONVENIENCE RECEPTACLE - 16" AFF U.O.N.GROUND FAULT INTERRUPTING RECEPTACLE - 16" AFF U.O.N.SPECIAL OUTLET CONFIGURATION - SEE NEMA #CEILING MOUNTED CORD REELCOMMUNICATIONS OUTLET (# = # OF CABLE DROPS) - 16" AFF U.O.N.FLOOR BOX WITH DUPLEX RECEPTACLE.NOTE: SEE ELECTRICAL DRAWINGS FOR COORDINATION.#ACRevisions:347 West 36 Street Suite 1501New York, NY 10018212-245-5195 T212-239-7130 FKey Plan:Notes:Grumman HallCornell UniversityIthaca, NY 14850Richard McElhiney Architects LLCMay 6, 2020Issue for Bid April 2, 2020Scale:31 Knight StreetNorwalk, CT 06851203-866-5538 T203-866-5243 FAltieri Sebor Wieber LLC303 South Broadway, Suite G20Tarrytown, NY 10591914-333-1110 T914-333-1109 FJacobs Consultancy4588 South Park AvenueBlasdell, NY 14219716-823-0006 TTrophy PointAREA OF WORK4592 Jordan RoadSkaneateles Falls, NY 13153315-685-4732 TRyan Biggs Clark Davis Engineering & SurveyingFirst and Second Floor Renovation Phase 11/4" = 1'-0"First Floor Furniture & EquipmentPlanA-1421/4" = 1'-0"1FIRST FLOOR FURNITURE & EQUIPMENT PLANAddendum 1 May 6, 20201111111111 -W1--W2-FIXED - HOLLOW METAL FRAMEFIXED - HOLLOW METAL FRAMEH1S1J2M1H1J1S2M2SEE SCHEDULESEE SCHEDULEM2-W3-FIXED - HOLLOW METAL FRAMESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE DOOR SCHEDULEEQEQEQEQEQEQEQEQEQEQEQS2H1J1GL-2GL-1GL-1NOTE: THIS FRAME WILL NOT FIT INTO THE SPACE AS ONE UNIT AND WILL BE CONSTRUCTED IN MULTIPLE PIECES. A KNOCK-DOWN FRAME IS PERMITTED FOR THIS FRAME. OTHER FRAMES TO BE FULLY WELDED.H12"1/2"1/2"5/8" GYPSUM BOARD EACH SIDE#20 GA. STEEL STUDS @16" O.C. W/ FIBER BLANKETEXTEND GYPSUM BOARD INTO FRAME 5/8" MIN.SEE PLANFILL H.M. FRAME VOIDS WITH FIBERGLASS INSULATION PRIOR TO WALL CONSTRUCTIONMETAL STUD BOX BEAM HEADERSECURE G.W.B. SHEATHING TO JAMB FRAMING AS REQUIREDHOLLOW METAL FRAMEGLAZING STOPDOUBLE GLAZED GLASS PANELJ12"SEE PLAN5/8" GYPSUM BOARD EACH SIDE(2) #16 GA. STEEL STUDS AT JAMBGLAZING STOPSECURE G.W.B. SHEATHING TO JAMB FRAMING AS REQUIREDWELDED H.M. #12 GA. STEEL FRAME. SET FRAME AND BRACE AS REQUIRED PRIOR TO WALL CONSTRUCTION#20 GA. STEEL STUDS @16" O.C. W/ FIBER BLANKETDOUBLE GLAZED GLASS PANELFILL H.M. FRAME VOIDS WITH FIBERGLASS INSULATION PRIOR TO WALL CONSTRUCTIONS12"FILL H.M. FRAME VOIDS WITH FIBERGLASS INSULATION PRIOR TO WALL CONSTRUCTIONHOLLOW METAL FRAMESECURE FRAMING TO SLAB AS REQUIREDFINISH FLOORDOUBLE GLAZED GLASS PANELGLAZING STOPS22"1/2"1/2"5/8" GYPSUM BOARD EACH SIDE#20 GA. STEEL STUDS @16" O.C. W/ FIBER BLANKETEXTEND GYPSUM BOARD INTO FRAME 5/8" MIN.SEE PLANFILL H.M. FRAME VOIDS WITH FIBERGLASS INSULATION PRIOR TO WALL CONSTRUCTION(2) #16 GA. STEEL STUDS AT SILLSECURE G.W.B. SHEATHING TO JAMB FRAMING AS REQUIREDHOLLOW METAL FRAMEDOUBLE GLAZED GLASS PANELM12"HOLLOW METAL FRAMEDOOR (SEE DOOR SCHEDULE)DOUBLE GLAZED GLASS PANELGLAZING STOPINTERIOR FRAME SCHEDULELEVEL WINDOW # ROOM # ROOM NAME TYPE WIDTH HEIGHT SILL HEIGHT FRAME TYPE FRAME MATERIAL FRAME FINISH HEAD DETAIL JAMB DETAIL SILL DETAIL MULLION DETAIL REMARKSFIRST FLOOR 1 182A PRINT ROOM W3 6'-0" 4'-0" 3'-0" A.F.F. F1 HM PT H1 J1 S2 ---- PROVIDE UV LIGHT BLOCKING GLASS FILMFIRST FLOOR 1 184 STUDENT SPACE W2 16'-8" (V.I.F.) 2'-6" 6'-0" A.F.F. F1 HM PT H1 J1 S2 M3FIRST FLOOR 2 184 STUDENT SPACE W1 21'-8" (V.I.F.) 8'-6" --- F1 HM PT H1 J2 S1 M1 PROVIDE GLASS MARKING AS PER NYS DoL PART 47FIRST FLOOR 3 184 STUDENT SPACE W2 16'-8" (V.I.F.) 2'-6" 6'-0" A.F.F. F1 HM PT H1 J1 S2 M3 PROVIDE OPAQUE GLASS FILMM2HOLLOW METAL FRAMEDOUBLE GLAZED GLASS PANELDOUBLE GLAZED GLASS PANELBUTT JOINT BETWEEN GLAZING2"3/4"SEE PLAN5/8" GYPSUM BOARD EACH SIDE(2) #16 GA. STEEL STUDS AT JAMB3/4" Z-CHANNEL REVEAL AROUND DOOR FRAME AT OUTSIDE FACE (TYP.)FILL H.M. FRAME VOIDS WITH FIBERGLASS INSULATION PRIOR TO WALL CONSTRUCTIONSECURE G.W.B. SHEATHING TO JAMB FRAMING AS REQUIREDWELDED H.M. #12 GA. STEEL FRAME. SET FRAME AND BRACE AS REQUIRED PRIOR TO WALL CONSTRUCTIONDOUBLE GLAZED GLASS PANEL#20 GA. STEEL STUDS @16" O.C. W/ FIBER BLANKETJ2Revisions:347 West 36 Street Suite 1501New York, NY 10018212-245-5195 T212-239-7130 FKey Plan:Notes:Grumman HallCornell UniversityIthaca, NY 14850Richard McElhiney Architects LLCMay 6, 2020Issue for Bid April 2, 2020Scale:31 Knight StreetNorwalk, CT 06851203-866-5538 T203-866-5243 FAltieri Sebor Wieber LLC303 South Broadway, Suite G20Tarrytown, NY 10591914-333-1110 T914-333-1109 FJacobs Consultancy4588 South Park AvenueBlasdell, NY 14219716-823-0006 TTrophy PointAREA OF WORK4592 Jordan RoadSkaneateles Falls, NY 13153315-685-4732 TRyan Biggs Clark Davis Engineering & SurveyingFirst and Second Floor Renovation Phase 1As indicatedWindow Schedule and DetailsA-6021/2" = 1'-0"Legend - Window Types1 1/2" = 1'-0"Window Head Detail - H11 1/2" = 1'-0"Window Jamb Detail - J11 1/2" = 1'-0"Window Sill Detail - S11 1/2" = 1'-0"Window Sill Detail - S21 1/2" = 1'-0"Window Mullion Detail - M11 1/2" = 1'-0"Window Mullion Detail - M21 1/2" = 1'-0"Window Jamb Detail - J2Addendum 1 May 6, 202011 FINISH TAG DESCRIPTION MANUFACTURER, MODEL NO., COLOR, SIZE, ETC.REMARKSACT-1 ACOUSTICAL CEILING TILE (2' x 2') ARMSTRONG ULTIMA TEGULAR FINE TEXTURE WITH 15/16 PRELUDE GRIDCPT-1 CARPET INTERFACE CARPET TILE, HONOR ROLL COLLECTION (COLOR T.B.D.)GWB-1 GYPSUM WALL BOARD SEE SPECIFICATIONSGWB-2 IMPACT RESISTANT GYPSUM WALL BOARD SEE SPECIFICATIONSPT-1 PAINT PAINT COLOR TO BE SELECTED BY THE ARCHITECTPT-2 PAINT PAINT COLOR TO BE SELECTED BY THE ARCHITECTRES-1 LINOLEUM HARMONIUM XF SHEET LINOLEUM BY JOHNSONITE (COLOR T.B.D.)RES-2 LINOLEUM HARMONIUM XF SHEET LINOLEUM BY JOHNSONITE (COLOR T.B.D.)RES-3 RESILIENT WALL BASE 4" HIGH x 1/8" THICK TRADITIONAL WALL BASE BY JOHNSONITEMATERIAL SCHEDULEBOTTOM OF EXISTING SLABCONTINUOUS SEALANT & FLAT TAPE BOTH SIDESFIRESTOPPING @ BOTH SIDESCEILING RUNNER WITH STUD BOLTS @ 24" O.C.(1) LAYER HIGH IMPACT GYPSUM WALL BOARD @ EACH SIDE20 GA. 3-5/8" METAL STUDS @ 16" O.C.3-1/2" ACOUSTICAL INSULATION (2-1/2" PCF MINERAL WOOL, TYP.)SEE FINISH SCHEDULE FOR FINISH MATERIAL20 GA. METAL RUNNER WITH STUD BOLTS @ 24" O.C.BASE, SEE FINISH SCHEDULECONTINUOUS SEALANT & FLAT TAPE BOTH SIDESFINISH FLOOR, SEE FINISH SCHEDULE+/-5"INTERIOR PARTITIONA0(2) LAYERS 5/8" FIRE RATED GYPSUM WALL BOARD20 GA. 2-1/2" J-SHAPE METAL RUNNER AT FLOOR, WALLS & CEILING1-1/2" FIBER BATT INSULATION IN CAVITYBASE, SEE FINISH SCHEDULECONTINUOUS SEALANT & FLAT TAPEFINISH FLOOR, SEE FINISH SCHEDULE2 HOUR FIRE RATED - UL #U415BINTERIOR PARTITIONB2NON FIRE RATED3 3/4"2' - 0"1" GYPSUM PANELS20 GA. 2-1/2" C-H METAL STUDS @24"O.C.PLANSECTIONBOTTOM OF EXISTING SLABCONTINUOUS SEALANT & FLAT TAPE BOTH SIDESCOMPRESSIBLE FLUTE FILLER(MINERAL WOOL PACKING)CEILING RUNNER WITH 1/2" STUD BOLTS @ 24" O.C.20 GA. METAL STUDS @ 16" O.C.GYPSUM WALL BOARDACOUSTICAL INSULATIONBOTTOM OF EXISTING SLABCOMPRESSIBLE FLUTE FILLER(MINERAL WOOL PACKING)CEILING RUNNER WITH 1/2" STUD BOLTS @ 24" O.C.20 GA. METAL STUDS @ 16" O.C.GYPSUM WALL BOARD, FIRE RATED ASSEMBLYACOUSTICAL INSULATIONFIRESTOPPING AT BOTH SIDES WITH FIRE RATING AS PER RATED WALL. SEE SPEC. FOR APPROVED MANUFACTURERS.1" MAX.FIRESTOPPING NOTES:1. FIRESTOPPING SHALL BE INSTALLED AS PER MANUFACTURER'S RECOMMENDED METHODS FOR THE REQUIRED FIRE RATING OF A WALL ASSEMBLY.2. ALTERNATE METHODS OF FIRESTOPPING MUST CONFORM TO U.L. REQUIREMENTS AND TO THE BUILDING CODE OF THE STATE OF NEW YORK.3. PROVIDE SLIP OR CUSHION TYPE JOINT BETWEEN METAL FRAMING AND STRUCTURE AS RECOMMENDED BY MANUFACTURER TO PREVENT TRANSFER OF LOADS OR MOVEMENT TO PARTITIONS.213AASECTION A-A13321. WALL ASSEMBLY -THE 1 HOUR FIRE-RATED GYPSUM BOARD/STUD ASSEMBLY.2. THROUGH PENETRANTS -ONE OR MORE PIPES OR CONDUITS INSTALLED IN SINGLE LAYER ARRAY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN THE PIPES AND CONDUITS AND THE EDGES OF THE OPENING SHALL BE MIN. 0 IN. (0 MM, POINT CONTACT) TO MAX 1-3/8 IN. (35 MM). THE SEPARATION BETWEEN THE PIPES AND CONDUITS TO BE A MIN. 0 IN. (0 MM, POINT CONTACT) TO A MAX. 1-1/4 IN. (32 MM). PIPES AND CONDUITS TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR CONDUITS MAY BE USED:A. STEEL PIPE -NOM. 2 IN. (51 MM) DIAM. (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE.B. CONDUIT -NOM. 2 IN. (51 MM) DIAM. (OR SMALLER) RIGID STEEL CONDUIT OR STEEL ELECTRICAL METALLIC TUBING (EMT).3. FILL VOID OR CAVITY MATERIALS BEARING THE U.L. CLASSIFICATION MARK -SEALANT -MIN. 5/8 IN. THICKNESS OF FILL MATERIAL INSTALLED TO COMPLETELY FILL ANNULAR SPACE BETWEEN PIPES, CONDUITS AND GYPSUM FLUSH WITH EACH SURFACE OF WALL. MIN. 1/2 IN. DIAM. BEAD OF FILL MATERIAL APPLIED TO THE THROUGH PENETRANT/WALL INTERFACE AT THE POINT CONTACT LOCATIONS ON BOTH SIDES OF THE WALL WITH THE 1 HOUR SEALANT.1' - 0"9 1/2"7/8" THUMBSLOT8 3/8"10 7/8"11"1/8" ACRYLIC BACKERINSERT SLOTVINYL TAPEFILLER1/16" NON-GLARE ACRYLICFILLERINTERIOR ROOM IDENTIFICATION SIGNAGE:1. A ROOM SIGN, AS DETAILED HERE, SHALL BE PROVIDED AND INSTALLED FOR EACH NEW DOOR IN THE PROJECT AREA.2. WHEN MOUNTING ON GLASS, PROVIDE BACKING (SAME SIZE AS SIGN) ON OPPOSITE SIDE OF THE GLASS.3. SUBMIT SHOP DRAWINGS SHOWING SCHEDULE LAYOUT, PROFILES AND PRODUCT COMPONENTS, INCLUDING MATERIAL DETAILS, DIMENSIONS, ANCHORAGE, AND ACCESSORIES FOR ARCHITECT'S REVIEW AND APPROVAL BEFORE STARTING FABRICATION.4. ALL SIGNAGE SYSTEMS SHALL MEET REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG) AND LOCAL AMENDMENTS AND MODIFICATIONS.5. RAISED LETTERING AND/OR NUMERALS: COMPUTER-CUT CHARACTERS WITH MATTE FINISH, COLOR AS SPECIFIED FROM MANUFACTURER'S STANDARD COLOR CHART. SHALL EXTEND A MINIMUM OF 1/32" FROM THE SIGN SURFACE. PHOTOPOLYMER TAGS SHALL NOT BE ACCEPTABLE.6. GRADE 2 BRAILLE: CLEAR RASTER BALLS COMPUTER DRILLED AND PRESSURE INSERTED INTO SIGN FACE, SHALL BE HALF-HEMISPHERE IN SHAPE AND SHALL EXTEND A MINIMUM OF 0.025" FROM THE SIGN SURFACE. OTHER METHODS OF MANUFACTURE, INCLUDING SURFACE APPLIED PHOTOPOLYMER BRAILLE TAGS SHALL NOT BE ACCEPTABLE.7. FASTENER: VERY HIGH BOND (VHB) .030 INCH THICK DOUBLE-FACE TAPE.FINISHES:1. COLORS AS SELECTED FROM THE MANUFACTURER'S STANDARD CHART.2. PATTERNS: AS SELECTED FROM THE MANUFACTURER'S STANDARD CHART.000RAISED CHARACTERS AND BRAILLE1/16" NON-GLARE ACRYLICPLASTIC SIGN FIELD1/8" SLIDING ACRYLIC LENS INSERTED INTO C-CHANNEL SHAPE FOR PAPER INSERT INSTALLATIONSPACE FOR PAPER INSERT0.06" CLEAR ACRYLIC UNDERSIZED BACKERPROVIDE BACK PLATE (SAME SIZE AND COLOR AS SIGN) WHEN MOUNTING ON GLASSRAISED CHARACTERS AND BRAILLEPLASTIC SIGN FIELD1/8" SLIDING ACRYLIC LENS INSERTED INTO C-CHANNEL SHAPE FOR PAPER INSERT INSTALLATIONSPACE FOR PAPER INSERTPROVIDE BACK PLATE (SAME SIZE AND COLOR AS SIGN) WHEN MOUNTING ON GLASSRevisions:347 West 36 Street Suite 1501New York, NY 10018212-245-5195 T212-239-7130 FKey Plan:Notes:Grumman HallCornell UniversityIthaca, NY 14850Richard McElhiney Architects LLCMay 6, 2020Issue for Bid April 2, 2020Scale:31 Knight StreetNorwalk, CT 06851203-866-5538 T203-866-5243 FAltieri Sebor Wieber LLC303 South Broadway, Suite G20Tarrytown, NY 10591914-333-1110 T914-333-1109 FJacobs Consultancy4588 South Park AvenueBlasdell, NY 14219716-823-0006 TTrophy PointAREA OF WORK4592 Jordan RoadSkaneateles Falls, NY 13153315-685-4732 TRyan Biggs Clark Davis Engineering & SurveyingFirst and Second Floor Renovation Phase 1As indicatedFinish Schedule and PartitionTypesA-603ROOM FINISH SCHEDULELevel Name Floor Finish Base Finish North Wall Finish East Wall Finish South Wall Finish West Wall Finish Ceiling Finish CommentsFIRST FLOOR 181 LAB I RES-1 RES-3 PT-1 PT-1 PT-1 PT-1 PT-2FIRST FLOOR 182 SADAF'S LAB RES-1 RES-3 PT-1 PT-1 PT-1 PT-1 PT-2FIRST FLOOR 100CA COMMON AREA RES-2 RES-3 PT-1 PT-1 PT-1 PT-1 PT-2FIRST FLOOR 184 STUDENT SPACE CPT-1 RES-3 PT-1 PT-1 PT-1 PT-1 ACT-1FIRST FLOOR 182A PRINT ROOM RES-1 RES-3 PT-1 PT-1 PT-1 PT-1 PT-2SECOND FLOOR 289 STUDENT WORKSTATIONS CPT-1 RES-3 PT-1 PT-1 PT-1 PT-1 PT-21 1/2" = 1'-0"1PARTITION TYPES3" = 1'-0"2ANCHOR DETAIL3" = 1'-0"3FIRESTOPPING DETAIL1 1/2" = 1'-0"4FIRESTOP DETAIL AT WALL PENETRATIONS (UL SYSTEM NO. W-L-1389)6" = 1'-0"5ROOM SIGNAGE DETAILAddendum 1 May 6, 20201111 3/S100 Issue for BidApril 2First and Second Floor Renovation Phase 1 BUTTERFLY VALVES GATE VALVES GLOBE VALVES CHECK VALVES STRAINERS BALL VALVES BALANCING VALVES CONTROL VALVES (2-WAY) CONTROL VALVES (3-WAY) FLEXIBLE CONNECTORS UNIONS HOT WATER SUPPLY, RETURNHWRHWS CHILLED WATER SUPPLY, RETURNCHRCHS CONDENSER WATER SUPPLY, RETURNCRCS LOW PRESSURE STEAM SUPPLY, RETURNLPRLPS MEDIUM PRESSURE STEAM SUPPLY, RETURNMPRMPS HIGH PRESSURE STEAM SUPPLY, RETURNHPRHPS SECONDARY CHILLED WATER SUPPLY, RETURNSCHRSCHS SECONDARY HOT WATER SUPPLY, RETURNSHWRSHWS HEAT RECOVERY SUPPLY, RETURNHRRHRS GLYCOL SUPPLY, RETURNGRGS CHILLED/ HOT WATER SUPPLY, RETURNC/HWRC/HWS CONDENSATECD PUMP DISCHARGEPD DUCT (WIDTH X HEIGHT)W x H ACOUSTICAL LINED DUCT (CLEAR INSIDE DIM.)W x H F FIRE DAMPER C C COMBINATION FIRE & SMOKE DAMPER S S SMOKE DAMPER MOTORIZED CONTROL DAMPERM VOLUME DAMPER (VD) FLEXIBLE CONNECTOR (FC) ELBOW DOWN - ELBOW UP LIGUID, HOT GAS, SUCTION (REFRIGERANT)HGL S ANCHOR POINT PIPE GUIDE END OF MAIN DRIPEOM CABLE OPERATED DAMPERCOD LINEAR DIFFUSER, CEILING DIFFUSERLD, CD LINEAR , CEILING, TOP, BOTTOM GRILLELG, CG, TG, BG LINEAR , CEILING, TOP, BOTTOM REGISTERLR, CR, TR, BR RETURN AIRRA OUTSIDE AIR INTAKEOAI NECKN, NK INSIDE DIMENSIONID ACCESS DOORAD ABOVE FINISHED FLOORAFF FLAT OVALFO VANE EXTRACTORVE F RETURN OR EXHAUST AIR SYMBOL SYMBOL LIST DESCRIPTION TEMPERATURE SENSORT HUMIDITY SENSORH SYSTEM WATER SUPPLY, RETURNSWRSWS ECCENTRIC REDUCER / INCREASERECC FIRE RATED ENCLOSUREFRE BY OTHER DIVISIONBOD FLAT ON TOPFT FLAT ON BOTTOMFB WIRE MESH SCREENWMS OPEN END DUCTOED ACOUSTICAL LININGAL ACOUSTICALLY LINED PLENUMALP CARBON DIOXIDE SENSORCO2 CARBON MONOXIDE SENSORCO REFRIGERANT SENSORRS BREAK GLASS SWITCHBG EXISTING DUCT TO REMAIN EXISTING PIPE TO REMAIN EXISTING DUCT TO BE REMOVED EXISTING PIPE TO BE REMOVED SUPPLY AIR VARIABLE REFRIGERANT FLOWVRF AIRFLOW MEASURING STATIONAFMS POINT OF CONNECTION EXISTING DUCT TO BE REMOVED EXISTING DUCT TO REMAIN EXISTING PIPE TO REMAIN EXISTING PIPE TO BE REMOVED A -SYMBOL - REFER TO SCHEDULE X - FACE SIZE, WIDTH, NUMBER OF SLOTS Y - NECK SIZE, LENGTH Z - CUBIC FEET PER MINUTE COMM. - COMMENT (OPTIONAL) X/Y/Z COMM . X/Y Z COMM .X Y Z COMM. REGISTERS, GRILLES, & DIFFUSERS TAGAA A W - INTERIOR WIDTH, H - INTERIOR HEIGHT L - INTERIOR LENGTH TW - TAP INTERIOR WIDTH DIMENSION TH - TAP INTERIOR HEIGHT DIMENSION COMM. - COMMENT (OPTIONAL) WxHxL ALP/TWxTH TAP COMM. WxHxL ALP TWxTH TAP COMM. ACOUSTICAL LINED PLENUM (ALP) TAG SYMBOL SYMBOL LIST DESCRIPTION LAST POINT OF REMOVAL APPLICABLE CODES BUILDING: MECHANICAL: ENERGY: PLUMBING: ELECTRICAL: GENERAL NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. ALL WORK SHALL BE IN CONFORMANCE WITH CODES AND REGULATIONS FOR THE STATE OF NEW YORK AS WELL AS ALL LOCAL CODES PERTAINING TO CITY OF ITHACA INCLUDING BUT NOT LIMITED TO: 2017 NYS UNIFORM CODE SUPPLEMENT 2015 INTERNATIONAL CODES (ICC) THE EXISTING CONDITIONS ARE BASED ON DESIGN DRAWINGS, LIMITED FIELD OBSERVATIONS, AND 3D DOCUMENTATION FOR SELECT AREAS. ANY DISCREPANCIES IN THE EXISTING CONDITIONS SHALL BY BROUGHT TO THE ATTENTION OF THE ENGINEER. HAZARDOUS MATERIAL REMEDIATION: IT IS KNOWN THAT IN A BUILDING OF THIS AGE, ISSUES WITH RESPECT TO "HAZARDOUS MATERIALS" AS DEFINED BY THE ENVIRONMENTAL PROTECTION AGENCY INCLUDING BUT NOT LIMITED TO LEAD PAINT AND ASBESTOS-CONTAINING BUILDING MATERIALS ARE PRESENT. ALL INQUIRIES WITH RESPECT TO DEALING WITH THE REMOVAL OF, SEALING OF, ABATEMENT OF, PENETRATIONS THROUGH, AND/OR ATTACHMENTS TO ANY HAZARDOUS MATERIALS SHALL BE DIRECTED TO THE HAZARDOUS MATERIALS CONSULTANT AND THE OWNER. THE MECHANICAL DRAWINGS DO NOT PROVIDE ANY REPRESENTATION OF HAZARDOUS MATERIALS. PRIOR TO CONSTRUCTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR RETRO- COMMISSIONING ALL EXISTING TO REMAIN EQUIPMENT & TERMINAL DEVICES. THE CONTRACTOR SHALL PROVIDE A REPORT TO THE OWNER OF THEIR FINDINGS INCLUDING AIRFLOW AND WATER BALANCE RATES AS WELL AS ANY DEFICIENCIES IN EXISTING: MOTORS, FANS, SENSORS, ACTUATORS, CONTROL VALVES, OR OTHER CONTROL DEVICES. FAN COIL UNITS SHALL BE PROVIDED WITH AUXILIARY DRAIN PANS WITH LEAK DETECTION SET TO DISABLE THE COOLING COIL UPON DETECTION. ALL CONDENSATE SHALL BE GRAVITY DRAINING TO EXISTING CONDENSATE RISER WITH AIR GAP CONDENSATE RETURNS TO THE STORM DRAINAGE SYSTEM. IN THE EVENT GRAVITY DRAINING IS NOT POSSIBLE CONDENSATE PUMPS SHALL BE PROVIDED WITH APPROVAL FROM THE ENGINEER AND THE BUILDING FACILITIES MANAGER. ALL LABORATORY SPACES SHALL BE BALANCED SUCH THAT A NEGATIVE PRESSURE IS MAINTAINED RELATIVE TO OFFICES, CORRIDORS, STUDENT WORK AREAS, OR OTHER NON LABORATORY SPACES. AREAS WITH ACCESS TO THE LABORATORY AREAS SHALL BE POSITIVELY PRESSURIZED TO MAINTAIN OVERALL AIR BALANCE IN THE BUILDING. ALL MECHANICAL EQUIPMENT & TERMINAL DEVICES INDICATED TO BE REMOVED ON THE DEMOLITION DRAWINGS SHALL BE TURNED OVER TO THE FACILITIES MANAGER FOR DETERMINATION OF STORAGE LOCATION OF REMOVED EQUIPMENT OR TO PROVIDE DIRECTION ON DISPOSAL OF EQUIPMENT. ALL NEW EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS GUIDELINES WITH PROPER SPACE MAINTAINED FOR ALL SERVICE AREA CLEARANCES. A SET OF COORDINATION DRAWINGS SHALL BE PRODUCED BY THE CONTRACTOR IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 230000 (1.16). IN ADDITION THE SUB CONTRACTORS SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO THE REMOVAL OR INSTALLATION OF ANY WORK AS REQUIRED TO INSTALL NEW WORK IN AN ORGANIZED FASHION. REBALANCE EXISITING SYSTEMS IMPACTED BY SCOPE. 1 Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 6, 2020 12" = 1'-0" Cover Sheet M-001 DRAWING LIST Sheet Number Sheet Name M-001 Cover Sheet DM-102 FIRST FLOOR- Demolition DM-103 SECOND FLOOR- Demolition DM-104 ROOF- Existing M-102 FIRST FLOOR- Ductwork M-103 SECOND FLOOR- Ductwork M-112 FIRST FLOOR - Piping M-113 SECOND FLOOR- Piping M-301 Details M-400 Flow & Control - Mechanical M-401 Flow & Control - Mechanical M-402 Flow & Control - Mechanical M-403 Flow & Control - Mechanical M-501 Schedules - Mechanical 12" = 1'-0"2 Applicable Codes HUMIDIFIER HEATING (OR COOLING) COIL OPPOSED BLADE DAMPER FAN (OR PUMP) AUTOMATIC 2-WAY VALVE MANUAL 2-WAY VALVE MANUAL BUTTERFLY VALVE AUTOMATIC BUTTERFLY VALVE CHECK VALVE STRAINER SPACE TEMPERATURE SENSOR SPACE HUMIDITY SENSOR TEMPERATURE TRANSMITTER HUMIDITY TRANSMITTER ELECTRIC MOTOR ROTARY SWITCH RELAY END SWITCH ELECTRIC-PNEUMATIC TRANSMITTER PNEUMATIC-ELECTRIC TRANSMITTER CONTROL RELAY ALARM BUZZER NORMALLY CLOSED CONTACT NORMALLY OPEN CONTACT MOMENTARY ON SWITCH MOMENTARY OFF SWITCH MOTOR THERMAL OVERLOADS CONTROL POINT ADJUSTMENT REVERSE ACTING DIRECT ACTING NORMALLY OPEN NORMALLY CLOSED HAND OFF AUTOMATIC MOTOR STARTER HEATER (ELECTRIC SUMP) VARIABLE SPEED DRIVE UNIT SMOKE DETECTOR DDC DIGITAL INPUT POINT DDC DIGITAL OUTPUT POINT DDC ANALOG OUTPUT POINT DDC ANALOG INPUT POINT DDC ALARM POINT DO DI AI AO A SD VS MS HOA NC NO DA RA CPA PE EP ES R M P H T H T SYMBOL LIST SYMBOL DESCRIPTION HTR M M DIFFERENTIAL PRESSURE AUTOMATIC 3-WAY VALVEM ALARM (OR INDICATION LAMP BACNET INTERFACEBN CARBON DIOXIDE TRANSMITTERCO2 AIR QUALITY TRANSMITTERAQ RS485 RS485 INTERFACE SWITCHS WATER DETECTORW FLOW SENSORF CURRENT SENSORCS ELECTRONICALLY COMMUTATED MOTORECM 1 1 1 012345678 9 A B D C E F CC 012345678 9 A B D C E F BB CC EAV-03 14Ø EXH. UP 315 CFM TO BE REMOVED 12"ø CAP 12"ø EXISTING CAPPED BRANCHES 12"ø 12"ø 12"ø 12Ø EXH. UP 12Ø EXH. UP → BALANCE TO 315 CFM 24x24 SA UP TO AHU-01 SOUND ATTENUATION 24"x18"VAV-02 12"ø 18"x15" 18"Ø PERF. BALANCE TO 1315 CFM EAV-02 12"ø12"ø12"ø FUME HOOD 785 CFM OCCUPIED 510 CFM UNOCCUPIED SAV-06 SAV-07 EAV-01 14"x10"12"ø 14"ø12"ø 24"x18"24"x18"FUME HOOD TO BE TURNED OVER TO CORNELL SAD-01 10"Ø PERF. 385 CFM TO BE REMOVED ← ← ← ← ← 10"ø 8"ø 8"Ø SA DUCT BALANCE 150 CFM 8"ø SUPPLY AIR VALVE TO BE REMOVED 12"ø 12Ø UP TO ROOM 294 12Ø UP TO ROOM 290 EXISTING CAPPED BRANCH 18"ø 16"ø12"ø 12"ø FCU 3/4" 3/4" 12"ø EXHAUST DUCT TO BE REMOVED 4"ø EXISTING RETURN INLET AND DUCTWORK TO BE REMOVED 4"ø 1-1/2"HWS/R DN 1"HWS/R UP TO 2ND FLOOR 4"HWS/R AT CEILING OF BASEMENT 1 1/4"HWR 1 1/4"HWS 1 1/4"HWR 1 1/4"HWS 1"HWS 1"HWR 1"HWR1"HWS 3/4"HWR 3/4"HWS 2 1/2"GWS 2 1/2"GWR 2"GWS 2"GWR 1 1/2"GWR 1 1/2"GWS EXISTING VALVED AND CAPPED 1-1/2"GWS/R 2"GWS/R TO AHU-1 ON ROOF ABOVE RM. 173 2-1/2"CHWS/R FROM BASEMENT TO AHU-1 ON ROOF ABOVE RM. 1732"GWR 2"GWS 2 1/2"CHS 2 1/2"CHR DN 3/4" 2"CD FROM AHU-1 3"SAN 3/4"HWR 3/4"HWS 1/2"HWS/R TO REHEAT COIL 4"Ø DN TO BE REMOVED ↑ EXHAUST VAV BOX TO BE REMOVED 17" UP TO LABORATORY EXHAUST FANS LEF-01 AND LEF-02 ON ROOF EXISTING EXHAUST AIR VALVE TO BE REMOVED EXISTING 8" DIAMETER TO BE REUSED SUPPLY AIR VALVE TO BE REMOVED EXHAUST VAV BOX TO BE REMOVED EXISTING AHU-2 SEE NOTE 1 EXISTING FAN COIL UNIT AND ASSOCIATED BRANCH PIPING TO BE REMOVED PIPING TO CONTINUE TO EXISTING10"Ø PERF 400 CFM SA TO BE REMOVED EXISTING SHUT-OFF VALVE 1"HWR1"HWS 3/4"CHS 3/4"CHR EXISTING VFD SERVING AHU-2 2 2 2 2 2 2 2 EXISTING FIRE WRAPPED DUCT TO REMAIN PIPING CONTINUES TO EXISTING 1 182 SADAF'S LAB 181 LAB I 184 STUDENT SPACE CAP EXISTING VACUUM DUCT 1 CAP EXISTING BRANCH 1 EXISTING REHEAT COILS TO REMAIN 3/4"HWS 3/4"HWR 1 1 1 1/2"CHS 1 1/2"CHR 1 1/2"HWR 1 1/2"HWS 1 1 1 Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 6, 2020 1/4" = 1'-0" FIRST FLOOR -Demolition DM-102 1/4" = 1'-0"1 FIRST FLOOR- Demolition NOTES: PROVIDE PRECONSTRUCTION AIR FLOW AND STATIC PRESSURE MEASUREMENT FOR SUPPLY RETURN, EXHAUST AND OUTSIDE AIR DUCTS AT SPECIFIED LOCATIONS AND FOR AHU-2. FOR ALL EXISTING FINTUBES TO REMAIN: a. REPLACE PNEUMATIC CONTROL VALVES WITH ELECTRIC CONTROLVALVES b. REPLACE BALANCING AND ISOLATION VALVES c. STRAIGHTEN AND CLEAN FINS 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 012345678 9 A B D C E F CC 012345678 9 A B D C E F BB CC CONTINUES TO EXISTING DUCTWORK 20"x10"20"x10"14"Ø UP 12"Ø UP 16"Ø UP 16"Ø UP 24x24 SA DN 24"x24" SOUND ATTENUATION 2 1/2"CHS 2 1/2"CHR 2 1/2"CHS 2 1/2"CHR FCU FCU FCU AHU-1 EXISTING FINTUBE RADIATION TO BE REUSED EXISTING HOT WATER RETURN TO REMAIN LOUVERED PENTHOUSE WITH OUTSIDE AIR CONNECTION TO AHU-2 24X24 DWN CONTINUES TO EXISTING CONTINUES TO EXISTING 1"CHS 1"CHR 1"HWR 1"HWS CONTINUES TO EXISTING 1"HWR CUH 3/4"HWS 3/4"HWS 3/4"HWS 3/4"HWR 3/4"HWR 3/4"HWR DOWNDOWNDOWN EXISTING FCU AND CORRESPONDING CHILLED WATER PIPING TO BE REMOVED BACK TO MAIN CONDENSATE LINE TO REMAIN AND BE CONNECTED TO NEW FCUS EXISTING AHU TO REMAIN 289 STUDENT WORKSTATIONS 1 1 Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 6, 2020 1/4" = 1'-0" SECOND FLOOR -Demolition DM-103 1/4" = 1'-0"1 SECOND FLOOR- Demolition NOTES: PROVIDE PRECONSTRUCTION AIR BALANCING MEASUREMENTS FOR SUPPLY, RETURN, EXHAUST, OUTSIDE AIR DUCTS AND FOR AHU-1. FOR ALL EXISTING FINTUBES TO REMAIN: a. REPLACE PNEUMATIC CONTROL VALVES WITH ELECTRIC CONTROLVALVES b. REPLACE BALANCING AND ISOLATION VALVES c. STRAIGHTEN AND CLEAN FINS 1 2 1 2 2 2 1 1 1 1 1 1 012345678 9 A B D C E F CC 012345678 9 A B D C E F BB CC 30"ø14"ø 12"ø 16"ø 16"ø DUCTWORK SUPPORTS TYPICAL FOR 2 EXISTING EXHAUST FAN AND STACK ROOF PENETRATION CURB BYPASS DAMPER AND WETHER HOOD EXISITING LABORATORY EXHAUST FANS LEF-01, LEF-02 → UP 24"Ø EXH. 20"x20" 18x18 EXH. BY-PASS 28" MIN. FILTER ACCESS CLEARANCE EXISITING AIR CLEANER WITH DUCTED BYPASS 16"ø Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 6, 2020 1/4" = 1'-0" ROOF-Existing DM-104 1/4" = 1'-0"1 ROOF- Existing EXHAUST DUCT DOWN TO 17" ROUND EXHAUST RISER NOTES: PROVIDE PRECONSTRUCTION AIR BALANCING MEASUREMENT FOR EXHAUST AIR DUCTS AND FOR LEF-1 & LEF-2.1 1 PRECONSTRUCTION AIRFLOW AND STATIC PRESSURE MEASURMENT REQUIRED FOR LEF 1&2 AIR CLEANER TO BE CONTINUOUSLY OFF AND AIR CLEANER DAMPERS TO BE LOCKED IN BYPASS MODE 1 MMTHT T TTT T 012345678 9 A B D C E F CC 012345678 9 A B D C E F BB CC 25"x12" 12"ø 20"x12" 8"ø 12"x12" 25"/8" EAV-6 181 LAB I 186 STUDENT SPACE 100CA COMMON AREA EXISTING AHU-2 24 X24 UP TO EXISTING AHU-1 ON ROOF 17" Ø ROUND UP TO LABORATORY EXHAUST FANS LEF-01 AND LEF-02 PN ROOF 14" Ø ROUND UP TO LEF-01 AND LEF-02 12" Ø ROUND UP TO LEF-01 AND LEF-02 24 X24 OA UP TO LOUVERED PENTHOUSE ON ROOF CAP EXISTING DUCT BALANCE TO 800 CFM BALANCE TO 800 CFM LAB 188 182 SADAF'S LAB DH-1 NEW MD IN OA DUCTWORK. BALANCE TO 300 CFM NEW MD IN RA DUCTWORK 20"ø 6"ø 12"ø 30"/12" 30"/12" 20"x12" 30"x12" 30"x12" 20"/12" 17"ø 17"ø 12"ø 10"ø 14"ø 10"ø 17"ø 20"/12" 14"ø 8"ø 8"ø 20"x12" 20"x12" 8"ø 8"ø 6"ø 6"ø 8"ø 12"x12" 12"ø SAV-3 SAV-1 SAV-2 RH-1 RH-3 RH-2 EAV-1 EAV-2 EAV-3 EAV-4 EAV-5 EAV-7 EAV-8 20"Ø FABRIC SUPPLY DUCT 1800 CFM 18"Ø FABRIC SUPPLY DUCT 735 CFM 10"Ø PERFERATED SUPPLY DUCT 300 CFM B/ 12"X12", 8" Ø 250 CFM SA (TYP-2) 4" Ø DOWN TO FUME EXTRACTOR ARM (TYP-4) D/ 22"X6" 333 CFM (TYP-3) A/ 18"X6" 315 CFM SA (TYP-4) D/ 22"X6" 417 CFM RA (TYP-3) C/ 30"x8" 500 CFM RA B/ 12"X12", 8" Ø 150 CFM SA B/ 12"X12", EXISTING 8" Ø BALANCED TO 150 CFM SA SERVING CORRIDOR D/ 22 x 6" 233 CFM (TYP-3) 182A PRINT ROOM EAV-9 FLEX DUCT TO BE USED FOR CONNECTION TO FUME HOOD FLEX DUCT TO BE USED FOR CONNECTION TO FUME HOOD EXISTING FIRE WRAPPED DUCT TO REMAIN FIRE WRAPPED DUCT EXISTING DUCT TO BE FIRE WRAPPED 12"ø VAV-1 VAV-2 CONDENSATE TO CLOSEST DRAIN EAV-EX2 EAV-EX1 SAV-EX2SAV-EX3 SAV-EX1 CAP EXISTING VACUUM DUCT 1 EXISTING REHEAT COILS TO REMAIN 1 D/ 18x6" 300 CFM 10"ø 10"ø 12"ø 12"ø 10"ø 1 25"x12" 1 EXISTING VFD SERVING AHU-2 14" x 20" OA CONNECTION TO AHU-2 NEW 14" x 10" EXHAUST DUCT CONNECTING EXISTING DUCTS Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 6, 2020 1/4" = 1'-0" FIRST FLOOR -Ductwork M-102 1/4" = 1'-0"1 FIRST FLOOR- Ductwork NOTES: PROVIDE PRECONSTRUCTION AIR FLOW AND STATIC PRESSURE MEASUREMENT FOR SUPPLY RETURN, EXHAUST AND OUTSIDE AIR DUCTS AT SPECIFIED LOCATIONS AND FOR AHU-2. REFER TO M-501 FOR AIR VALVE AIRFLOW SCHEDULE TRANSFER EXISTING CONTROL POINTS FROM EXISTING JCI PANEL TO NEW ALC PANEL 1 2 3 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 T 012345678 9 A B D C E F CC 012345678 9 A B D C E F BB CC FCU-2 FCU-1 289 STUDENT WORKSTATIONS 480 AHU-1 HORIZONTAL CABINET STYLE FCU 320 CFM (TYP-2) 14"ø EXISTING AHU-1 TO REMAIN EXISITING OA INTAKE SERVING AHU-2 24X24 DWN AIRFLOW DIRECTION 20"x10" 20"x10" 1 Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 6, 2020 1/4" = 1'-0" SECOND FLOOR -Ductwork M-103 1/4" = 1'-0"1 SECOND FLOOR- Ductwork NOTES: PROVIDE PRECONSTRUCTION AIR BALANCING MEASUREMENTS FOR SUPPLY, RETURN, EXHAUST, OUTSIDE AIR DUCTS AND FOR AHU-1. FOR ALL EXISTING FINTUBES TO REMAIN: a. REPLACE PNEUMATIC CONTROL VALVES WITH ELECTRIC CONTROLVALVES b. REPLACE BALANCING AND ISOLATION VALVES c. STRAIGHTEN AND CLEAN FINS TRANSFER EXISTING CONTROL POINTS FROM EXISTING JCI PANEL TO NEW ALC PANEL 1 2 1 1 1 3 1 1 REF. THT T TTT T 012345678 9 A B D C E F CC 012345678 9 A B D C E F BB CC 2"HWS 2"HWR AHU-2 184 STUDENT SPACE 563 182 SADAF'S LAB 754 188 495 RH-3 RH-1 RH-2 2" HWS/R DOWN TO 4" HWS/R AT BASEMENT CEILING 3/4"HWS 3/4"HWR 3/4"HWS 3/4"HWR 3/4"HWR 3/4"HWS 3/4"HWR 3/4"HWS 3/4"HWS 1"HWR 3/4"HWR 3/4"HWS 1"HWS 1"HWR 3/4"HWR 3/4"HWS 1"HWS 3/4"HWR 1"HWR 3/4"HWS 1"HWS 3/4"HWR 1"HWR 3/4"HWS 1"HWS 3/4"HWR 1"HWR 3/4"HWS 1"HWS 1"HWR3/4"HWR 3/4"HWS 1"HWS 3/4"HWR 1"HWR 3/4"HWS 1"HWS 2"GWS 2"GWR1 1/2"GWS 1 1/2"GWR CV-1 CV-2 CV-3 CV-4 CV-5 VAV-1 VAV-2 3/4"HWR 3/4"HWS 1"HWR1"HWS 1"HWR 1"HWS 1"HWS 1"HWR 1"HWR1"HWS 2"CHS 2"CHR 1"CD 3/4"CHS3/4"CHR 3/4"CHS 3/4"CHR 3/4"CD 2"CHS 2"CHR 1"CD 2"CHS 2"CHR 1"CD 1 1/4"HWR 1 1/4"HWS 1"HWR 1"HWS 3/4"HWS 3/4"HWS CONTINUE TO EXISTING PIPING CONTINUE TO EXISTING PIPING CONTINUE TO EXISTING PIPING CONTINUE TO EXISTING PIPING CONTINUE TO EXISTING PIPING 181 LAB I CONTINUE TO EXISTING PIPING CONTINUE TO EXISTING PIPING CONTINUE TO EXISTING PIPING CONTINUE TO EXISTING PIPING 3/4"HWR CONTINUE TO EXISTING PIPING DOWN TO CHW COIL CONNECTION 1 EXISTING REHEAT COILS TO REMAIN EXISTING REHEAT COILS TO REMAIN 1 DOWN TO GLYCOL PREHEAT COIL CONNECTION Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 6, 2020 1/4" = 1'-0" FIRST FLOOR -Piping M-112 1/4" = 1'-0"1 FIRST FLOOR- Piping NOTES: FOR ALL EXISTING FINTUBES TO REMAIN: a. REPLACE PNEUMATIC CONTROL VALVES WITH ELECTRIC CONTROL VALVES b. REPLACE BALANCING AND ISOLATION VALVES c. STRAIGHTEN AND CLEAN FINS 1 1 1 1 1 1 1 1 TERMINAL BOX INSTALLATION DETAIL STRAINER ISOLATION VALVE (TYPICAL) BALANCING VALVE CONTROL VALVE DUCT TRANSITION PRESSURE & TEMPERATURE PORT (TYPICAL) MANUAL AIR VENT M HWSHWRUNION (TYPICAL) 3/4" DRAIN VALVE WITH CAP HEATING COIL DUCT TRANSITION RECTANGULAR TO ROUND TERMINAL BOX & HEATING COIL ACCESS DOOR TRANSITION AS REQUIRED 2'-0" MINIMUM 1 M301M301 N.T.S. PIPE PENETRATIONS CORE DRILLED UL LISTED FIRESTOP SYSTEM. REFER TO SPECIFICATIONS. WITH T-RATING WITHOUT T-RATING 2" WELDED WATER STOP (NEW CONSTRUCTION) 2 M301M301 N.T.S. PIPE RISER W/ INSULATION 1/4" THICK STEEL X 2" WIDE SUPPORT RING SECURE AND SEAL TO FLOOR (TYP) SCHEDULE 40 PIPE SLEEVE SEAL SLEEVE WITH EXPANDING CONCRETE GROUT AS REQ'D (EXIST'G CONSTRUCTION) NOTES: 1. ALL PENETRATIONS THROUGH RATED CONSTRUCTION SHALL BE FIRE STOPPED WITH AN APPROVED UL LISTED/FM APPROVED FIRESTOP SYSTEM MEETING ASTM E-814 & UL 1479. 2. FIRESTOP SYSTEM SHALL BE FIRE RATED (F-RATING) AND THERMAL RATED (T-RATING) EQUAL TO CONSTRUCTION RATING WITH A MINIMUM OF 1 HOUR. 3. THERMAL RATING (T-RATING) IS NOT REQUIRED WHEN THE APPLICABLE CODE(S) HAVE AN EXCEPTION FOR THE SPECIFIC INSTALLATION CONDITION. 4. PENETRATIONS THROUGH NON-RATED CONSTRUCTION SHALL BE SEALED WITH AN APPROVED NON-COMBUSTIBLE MATERIAL TO RESIST THE PASSAGE OF FLAMES AND THE PRODUCTS OF COMBUSTION. WELDED WATER STOP (EXISTING CONSTRUCTION) SECURE AND SEAL TO FLOOR 2" and Smaller 2 1/2" and Larger Fluids 150°F -250°F (15psi Steam) - 50' from Anchor Fluids greater than 250°F - 30' from Anchor Fluids greater than 100°F 2" and Smaller 2 1/2" and Larger Fluids less than 100°F 2" and Smaller 2 1/2" and Larger 12" RIGID INSULATION 12" SHIELD HANGER PIPE INSULATION 18" RIGID INSULATION 18" SHIELD ROD DOUBLE NUTS AND WASHERS 12" RIGID INSULATION 12" SHIELD INSULATION INSERT SADDLE HANGER SCHEDULE PIPE SIZE ROD SIZE MAX. SPACING up to 1 1/4" up to 1 1/2" 1 1/2" & 2" 2 1/2" & 3" 4" & 5" 6" 8", 10", 12" 14" & 16" 18" 3/8" DIA. 3/8" DIA. 3/8" DIA. 1/2" DIA. 5/8" DIA. 3/4" DIA. 7/8" DIA. 1" DIA. 1 1/8" DIA. 8' Steel 6' Copper & Steel 10' 10' 10' 10' 10' 10' 10' PIPE HANGER DETAIL3 M301M301 N.T.S. TYPICAL VOLUME DAMPER LOCATIONS6 M301M301 N.T.S. NOTES: 1.PROVIDE VOLUME DAMPERS IN EVERY BRANCH AND DIFFUSER BRANCH AS SHOWN ABOVE. 2.PROVIDE ADDITIONAL VOLUME DAMPERS AS SHOWN ON CONTRACT DOCUMENTS. 3.VOLUME DAMPERS SHALL BE CABLE OPERATED (COD) WHERE LOCATED ABOVE OR BEHIND INACCESSIBLE SURFACES. 4.TYPICAL FOR SUPPLY, RETURN, EXHAUST AND VENTILATION AIR. MAIN DUCT BRANCH DUCT VOLUME DAMPER (VD) OR COD (TYPICAL) RADIUS TAP(TYPICAL) DIFFUSER BRANCH DUCT (TYPICAL) VD VD VDVD SQUARE ELBOW DOUBLE THICKNESS VANES BRANCH DUCT SUPPLY TAP X X 12" MAX AIRFLOW 12" MAX X AIRFLOW BRANCH DUCT RETURN TAP AIRFLOW R R=W W SUPPLY SPLITRADIUS ELBOWCOIL OR REGISTER R R=W W WAIRFLOW DUCT TAP TO REHEAT COIL OR REGISTER VOLUME EXTRACTOR WITH MANUAL ADJUSTING LEVER 20DEG MAX TRANSITION DUCT CONSTRUCTION DETAILS NOTE: SPECIFICATIONS EXCEED SMACNA STANDARDS IN SOME INSTANCES. SMACNA SHALL BE CONSIDERED THE MINIMUM STANDARD UNLESS OTHERWISE NOTED 7 M301M301 N.T.S. X DUCT HANGER (TYP) END CAP SUPPLY DIFFUSER OR RETURN/EXHAUST GRILLE DUCT VOLUME DAMPER CEILING FRAMING SUSPENSION SYSTEM BY OTHER DIVISION 3'-0" MAX. DUCT SIZE TO MATCH DIFFUSER NECK SIZE REFER TO SCHEDULE VD CEILING-REFER TO REFLECTED CEILING PLANS FOR CEILING TYPE AND DIFFUSER LOCATION NOTE: PROVIDE DIFFUSER W/ OPPOSED BLADE CABLE OPERATED DAMPER AND IN-AIRSTREAM OPERATORS WHERE INSTALLED IN HARD INACCESSIBLE CEILING. TYPICAL SUPPLY, RETURN AND EXHAUST OUTLET DETAIL10 M301M301 N.T.S. TYPE "C" FOAMGLAS INSULATION WATERPROOFING (BY OTHER DIVISION) SILICONE CAULKING AROUND FULL PERIMETER OF ANGLES - INSIDE AND OUTSIDE DUCT OUTSIDE INSIDE 12" MIN CONTINUOUS 18 GA ALUMINUM ANGLE AROUND FULL PERIMETER OF DUCT INSIDE AND OUTSIDE INSULATE PER SPECIFICATIONS MAINTAIN VAPOR BARRIER DUCT PENETRATION THROUGH WALL8 M301M301 N.T.S. METAL DECK HANGER BOLTS CONCRETE DECK INSERTS BEAM CLAMPS SUPPLEMENTAL STEEL WELDING PROCEDURE TO BE SUBMITTED FOR REVIEW INTERMEDIATE ATTACHMENT ONE SIZE LARGER THAN LARGEST HANGER ROD END ATTACHMENT TO BE SAME AS LARGEST HANGER ROD SQUARE STEEL WASHER TYP BACK TO BACK STRUCTURAL SHAPES WITH SPACERS WELDED AT 24" INTERVALS TWO HANGER RODS MAXIMUM BETWEEN STRUCTURE ATTACHMENTS PIPE HANGER ATTACHMENT DETAIL5 M301M301 N.T.S. HWR HWS A STRAINER BALANCING VALVE AIR VENT TYPICAL PRESSURE & TEMPERATURE PORT (TYPICAL) ISOLATION VALVE BLOWDOWN VALVE CONTROL VALVE REDUCER COIL NO.A HOSE END GATE VALVE UNION (TYPICAL) HOT WATER REHEAT COIL9 M301M301 N.T.S. RH-1 THRU 3 3/4" CONTROL VALVE (TYP) UNION (TYP) COOLING COIL BALANCE & FLOW VALVE (TYP) ISOLATION VALVE (TYP) HORITZONTAL FAN COIL UNIT HEATING COIL CONDENSATE DRAIN PAN WATER SENSOR AUXILIARY DRAIN NOTE: PROVIDE AUXILIARY DRAIN TO APPROVED LOCATION AND WATER SENSOR TO SHUT DOWN UNIT. HORIZONTAL CABINET FAN COIL UNIT CD HWS HWR CHS CHR 4 M-301M-301 N.T.S. 1 ISOLATION VALVE 1 ISOLATION VALVE 1 REGEN. EXHAUST TO EAV-2 SUPPLY AIR FROM SAV-3 REGEN. INTAKE PROCESS SUPPLY DEHUMIDIFIER DETAIL11 M301M301 N.T.S. DX COOLING COIL REGEN AIR CONDENSING HEATING COIL DESICCANT WHEEL FILTER SUPPLY AND EXHAUST FANS SHALL BE REMOVED FROM THE UNIT AND STORED AT A LOCATION DETERMINED BY THE FACILITIES MANAGER. 1 HWS DRAIN VALVE (@LOW POINT) UNION (TYP) BALANCE & FLOW VALVE MANUAL AIR VENT (@ HIGH POINT) P IT C H U P FINTUBE INCREASER / REDUCER AS REQUIRED (TYP) CONTROL VALVE WHERE INDICATED ISOLATION VALVE FINTUBE RADIATION DETAIL TO SPACE THERMOSTAT 12 M-301M-301 N.T.S. HWR ISOLATION VALVE PROVIDE NEW VAVLE ASSEMBLY TO EXISTING FINTUBE PERIMETER RADIATION. TIE INTO EXISTING HWS/R RISERS. Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 6, 2020 12" = 1'-0" Details M-301 OVERALL AIRFLOW DIAGRAM SCALE: NONE 1 M-400M-400EAV-6EAV-3EAV-1AO AI COM BACnet/MSTPAV AO AI COM BACnet/MSTPAV 17"Ø EXHAUSTDUCT UP TO EXISTING LEF-01 & LEF-02 ON ROOF 12"Ø EXHAUSTDUCT UP TO EXISTING LEF-01 & LEF-02 ON ROOF FUME HOOD GAS CABINET FURNACE CANOPY HOODEAV-4AO AI COM BACnet/MSTPAV FUME EXTRACTION ARMEAV-5AO AI COM BACnet/MSTPAV EAV-8AO AI COM BACnet/MSTPAV GENERAL EXHAUST FUME HOOD GENERALEXHAUST FUME EXTRACTION ARM 24"x24" SUPPLY DUCT DN FROM EXISTING AHU ON ROOF 12"Ø EXHAUSTDUCT TO OUT OFSCOPE LAB AREA SAV-3 AHU-1SUPPLY AIR ETR SUPPLYDUCT TO OUTOF SCOPEAREA SAV-1 AO AI COM BACnet/MSTPAV SAV-2AHU-1 SUPPLY AIR AHU-1 SUPPLY AIR 182A PRINT ROOM182 SADAF'S LAB 180 LAB I GENERALEXHAUST 14"Ø EXHAUSTDUCT UP TO EXISTING LEF-01 & LEF-02 ON ROOF AO AI COM BACnet/MSTPAV EXIST. FUME HOOD EAV-EX1AO AI COM BACnet/MSTPAV EAV-EX2EXIST.GENERALEXHAUST 188 LAB AO AI COM BACnet/MSTPAV AO AI COM BACnet/MSTPAV HC ~HWS HWR~AO HC ~HWS HWR~HC ~HWS HWR~AO AO NOTES: REFER TO M-401 FOR SEQUENCES AND POINTS LIST. TRANSFER EXISTING CONTROL POINTS FROM EXISTING JCI PANEL TO NEW ALC PANEL EAV-2DH-1 SAV-EX1HCEX~HWSHWR ~AO AO AICOM BACnet/MSTP AV SAV-EX2HCEX~HWSHWR ~AO AO AICOM BACnet/MSTP AV EXIST. SUPPLY AI T OCC DI AO PERIMETER RADIATION AO PERIMETER RADIATION NEW CONTROLVALVE ON HWR AI & HUMIDITY SENSORS SPACE TEMPERATURE H DO NEW CONTROLVALVE ON HWR AI T AI & OCCUPANCY SENSORS SPACE TEMPERATURE, HUMDITY T OCC DI AI & OCCUPANCY SENSORS SPACE TEMPERATURE T OCC DI AO AI COM BACnet/MSTP AV AO AICOM BACnet/MSTP AV FUME HOOD FUME HOOD CONTROLLER VERTICAL SASHSENSOR HORIZONTAL SASH SENSOR FUME HOODDISPLAY FUME HOOD EXHAUST VALVE TYPICAL FUME HOOD CONTROLLER DETAIL SCALE: NONE 2 M-400M-400 A A A A A AA A A A A A A A AI T AI T AI T AI T AI T AI T AI H AI T AI H LINE TYPE LEGEND NEW WORK EXISTING TO REMAIN AI H AI H AO AICOM BACnet/MSTP AV A FUME EXTRACTION ARM FUME EXTRACTION ARMEAV-7AO AICOM BACnet/MSTP AV A AI H DI EAV-9AO AI COM BACnet/MSTPAV A & OCCUPANCY SENSORS SPACE TEMPERATURE, HUMDITY 1 2 ETR SUPPLY DUCT TO OUT OF SCOPE AREASAV-EX3HCEX~HWSHWR ~AO AO AICOM BACnet/MSTP AV A AI T RH-3 RH-1 RH-2 CV-3 CV-1 CV-2 EXISITING CONTROL VALVE (TYP-3) 1 1 Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 6, 2020 12" = 1'-0" Flow & Control -Mechanical M-400 1 1 1 11 1 DI DO AI AO AV BV SCH TREND BACS SOFTWARE POINTSHARDWARE POINTS ALARM DESCRIPTION SHOWN ON GRAPHIC NOTESLAB PREP ROOM 200C SUPPLY AIR VALVE (SAV-1 , 2, 3, & EX) MAX AIRFLOW SETPOINT (CFM) SUPPLY AIR VALVE (SAV-1 , 2, 3, & EX) POSITION COMMAND (CFM) SPACE TEMPERATURE SETPOINT (DEG F) REHEAT COIL (RH-1, 2, 3, EX) VALVE POSITION COMMAND (%) X X X XX REHEAT COIL (RH-1, 2, 3, EX) LEAVING AIR TEMPERATURE (DEG F) SUPPLY AIR VALVE (SAV-1 , 2, 3, & EX) FLOW FEEDBACK (CFM) SUPPLY AIR VALVE (SAV-1 , 2, 3, & EX) MIN AIRFLOW SETPOINT (CFM) X XX X X X X X X X X XX SPACE TEMPERATURE (DEG F) SPACE OCCUPANCY X X X X X X SUPPLY AIR VALVE (SAV-1 , 2, 3, & EX) STATUS X X X X 10% FLOW DEVIATION FROM SETPOINT JAM ALARM LOW DIFFERENTIAL PRESSURE X TRI-STATE ALARM X EXHAUST AIR VALVE (EAV-1 THRU 9 & EX1 & EX2) MAX AIRFLOW SETPOINT (CFM) EXHAUST AIR VALVE (EAV-1 THRU 9 & EX1 & EX2) POSITION COMMAND (CFM) X EXHAUST AIR VALVE (EAV-3, 6, 7, 8, 9, EX1, & EX2) FLOW FEEDBACK (CFM) EXHAUST AIR VALVE (EAV-1 THRU 9 & EX1 & EX2)MIN AIRFLOW SETPOINT (CFM) XX X X X X X X XX X EXHAUST AIR VALVE (EAV-1 THRU 9 & EX1 & EX2) STATUS X X X X 10% FLOW DEVIATION FROM SETPOINT JAM ALARM LOW DIFFERENTIAL PRESSURE X TRI-STATE ALARM EXHAUST AIR VALVE (EAV-1, 2, 4, & 5)FLOW FEEDBACK (CFM)X X X EXHAUST AIR VALVE (EAV-1, 2, 4, & 5) STATUS X X X JAM ALARM LOW DIFFERENTIAL PRESSURE X TWO-STATE ALARM FUME HOOD SASH POSITION FEEDBACK X X XXSASH OPEN FOR 24 CONTINUOUS HOURS OR MORE FUME HOOD OCC/UNOCC/HIBERNATION COMMAND XX TRI-STATE OUTPUT POINT PERIMETER RADIATION CONTROL VALVE COMMAND (%)XXX EXHAUST AIR VALVE (EAV-1, 2, 4, & 5) POSITION COMMAND (CFM)XXX INTERLOCKED TO FUME HOOD SEQUENCE OF OPERATION ZONE CONTROL: 182 SADAF'S LAB CONTROL A.SYSTEM DESCRIPTION 1. 2. 3. 4. 5. 6. 7. SUPPLY AIR VALVE (SAV-2) CANOPY HOOD EXHAUST AIR VALVE (EAV-1) GAS CABINET EXHAUST AIR VALVE (EAV-3) FUME EXTRACTION ARM EXHAUST AIR VALVE (EAV-4) FUME EXTRACTION ARM EXHAUST AIR VALVE (EAV-5) VARIABLE FUME HOOD EXHAUST AIR VALVE (EAV-6) GENERAL EXHAUST AIR VALVE (EAV-7) B.LABORATORY AIRFLOW CONTROL OCCUPIED MODE 1. 2. 3. 4. 5. WHEN THE ROOM IS OCCUPIED, THE ROOM EXHAUST & SUPPLY MIN/MAX RATES SHALL CORRESPOND TO THE LAB AIRFLOW MATRIX VALUES FOR OCCUPIED MODE. THE BACS SHALL SEND AN OCCUPIED COMMAND TO THE FUME HOOD CONTROLLER. THE FUME HOOD CONTROLLER SHALL INDEX THE FUME HOOD SASH POSITION. THE FUME HOOD EXHAUST VALVE (EAV-6) CONTROLLER SHALL MODULATE THE EXHAUST VALVE TO MAINTAIN THE REQUIRED 100 FPM FACE VELOCITY SETPOINT BASED ON SASH POSITION. THE CANOPY HOOD, GAS CABINET, AND FUME EXTRACTION ARM EXHAUST AIR VALVES (EAV-1,EAV-3,EAV-4,EAV-5 RESPECTIVELY) SHALL ADJUST TO THEIR OCCUPIED EXHAUST RATE POSITIONS. THE GENERAL EXHAUST VALVE (EAV-7) SHALL MODULATE TO MAINTAIN THE OVERALL ROOM AIRFLOW OFFSET BASED ON THE TOTAL ROOM EXHAUST AND SUPPLY AIRFLOW RATES. THE SUPPLY AIR VALVE (SAV-2) SHALL MODULATE BETWEEN ITS MAX & MIN POSITIONS BASED ON THE ROOM TEMPERATURE SETPOINT & REQUIRED AIR FOR EXHAUST OFFSET (REFER TO LAB AIRFLOW MATRIX). THE SUPPLY VALVE SHALL NOT BE ALLOWED TO MODULATE BELOW ITS REQUIRED MINIMUM AIR POSITION FOR THE CURRENT OVERALL ROOM EXHAUST RATE. C.LABORATORY AIRFLOW CONTROL UNOCCUPIED MODE 1. 2. 3. 4. 5. WHEN THE ROOM IS UNOCCUPIED, THE ROOM EXHAUST & SUPPLY MIN/MAX RATES SHALL CORRESPOND TO THE LAB AIRFLOW MATRIX VALUES FOR UNOCCUPIED MODE UNLESS STATED OTHERWISE BELOW. THE FUME HOOD CONTROLLER SHALL INDEX THE FUME HOOD SASH POSITION. IF THE SASH POSITION IS BELOW 18" THE BACS SHALL SEND AN UNOCCUPIED COMMAND TO THE FUME HOOD CONTROLLER. THE FUME HOOD EXHAUST VALVE (EAV-6) CONTROLLER SHALL MODULATE THE EXHAUST VALVE TO MAINTAIN THE REQUIRED 80 FPM (ADJUSTABLE) FACE VELOCITY SETPOINT BASED ON SASH POSITION. IF THE SASH POSITION IS ABOVE 18" THE BACS SHALL NOT SEND AN UNOCCUPIED COMMAND TO THE FUME HOOD CONTROLLER. THE FUME HOOD EXHAUST VALVE (EAV-6) CONTROLLER SHALL MODULATE THE EXHAUST VALVE TO MAINTAIN THE REQUIRED 100 FPM FACE VELOCITY SETPOINT BASED ON SASH POSITION. THE CANOPY HOOD, GAS CABINET, AND FUME EXTRACTION ARM EXHAUST AIR VALVES (EAV-1,EAV-3,EAV-4,EAV-5 RESPECTIVELY) SHALL ADJUST TO THEIR UNOCCUPIED EXHAUST RATE POSITIONS. THE GENERAL EXHAUST VALVE (EAV-7) SHALL MODULATE TO MAINTAIN THE OVERALL ROOM AIRFLOW OFFSET BASED ON THE TOTAL ROOM EXHAUST AND SUPPLY AIRFLOW RATES. THE SUPPLY AIR VALVE (SAV-2) SHALL MODULATE BETWEEN ITS MAX & MIN POSITIONS BASED ON THE ROOM TEMPERATURE SETPOINT & REQUIRED AIR FOR EXHAUST OFFSET (REFER TO LAB AIRFLOW MATRIX). THE SUPPLY VALVE SHALL NOT BE ALLOWED TO MODULATE BELOW ITS REQUIRED MINIMUM AIR POSITION FOR THE CURRENT OVERALL ROOM EXHAUST RATE. D.LABORATORY AIRFLOW CONTROL HIBERNATION MODE 1.THE ROOM SHALL BE CAPABLE OF BEING MANUALLY SET INTO "HIBERNATION MODE". A LIST OF EQUIPMENT THAT CAN BE TURNED OFF VIA CLOSING BLAST GATES AS WELL AS ANY ADDITIONAL REDUCED AIRFLOW RATES FROM THE UNOCCUPIED MODE SHALL BE PREDETERMINED BY THE FACILITIES ENGINEER AND HEALTH AND SAFETY OFFICER (HSO). THE EXHAUST AIR VALVES SERVING CLOSED OFF EQUIPMENT SHALL BE CLOSED. THE OVERALL ROOM ACH SHALL NOT FALL BELOW 3 ACH AS DETERMINED BY THE HSO. ANY EQUIPMENT DETERMINED NOT TO BE CLOSED DOWN SHALL ENTER INTO UNOCCUPIED MODE. THE SUPPLY AIR VALVE SHALL BE ALLOWED TO RESET DOWN TO ITS HIBERNATION MODE MINIMUM. THE GENERAL EXHAUST VALVE SHALL CONTINUE TO TRACK THE OVERALL ROOM EXHAUST TO MAINTAIN REQUIRED ROOM OFFSET. E.LABORATORY GAS DETECTION 1.UPON A GAS DETECTION INPUT FROM THE GAS DETECTION PANEL, THE BACS SHALL OVERRIDE THE ROOM OCCUPANCY AS OCCUPIED. THE FUMEHOOD, CANOPY HOOD, FUME EXTRACTION ARMS AND GENERAL EXHAUST AIR VALVES SHALL MAINTAIN THEIR OCCUPIED MODE OPERATION. THE GAS CABINET EXHAUST AIR VALVE (EAV-3) SHALL OPEN TO ITS EMERGENCY AIRFLOW RATE AS DETERMINED BY THE HSO. THE SUPPLY AIR EXHAUST VALVE SHALL BE ALLOWED TO MODULATE UP TO ITS EMERGENCY SUPPLY RATE AS REQUIRED TO MAINTAIN THE ROOM EXHAUST AIRFLOW OFFSET. F.ZONE TEMPERATURE CONTROL 1. 2. 3. WHEN THE SPACE TEMPERATURE SETPOINT IS MET THE SUPPLY AIR VALVE (SAV-2) SHALL MODULATE TOWARDS ITS MINIMUM POSITION BASED ON THE CURRENT ROOM EXHAUST AIRFLOW RATE, THE HOT WATER CONTROL VALVE ASSOCIATED WITH SAV-2 SHALL MODULATE TO MAINTAIN A SUPPLY AIR TEMPERATURE OF 70.0°F TO THE SPACE. THIS SHALL BE CONSIDERED NEUTRAL OPERATION FOR THE SUPPLY VALVE. UPON A CALL FOR COOLING THE HOT WATER CONTROL VALVE ASSOCIATED WITH SAV-2 SHALL CLOSE. IF AFTER A PERIOD OF 15 MINUTES (ADJUSTABLE) THE SPACE IS CALLING FOR ADDITIONAL COOLING THEN THE SUPPLY VALVE SHALL MODULATE TOWARDS ITS MAXIMUM AIRFLOW POSITION. UPON A CALL FOR HEATING THE SUPPLY AIR VALVE SHALL CONTINUE TO MAINTAIN A SUPPLY AIR TEMPERATURE OF 70.0°F AT ITS MINIMUM POSITION. THE PERIMETER RADIATION HOT WATER CONTROL VALVE SHALL MODULATE OPEN. IF AFTER A PERIOD OF 15 MINUTES (ADJUSTABLE) THE ROOM IS CALLING FOR ADDITIONAL HEATING, THE HOT WATER CONTROL VALVE ASSOCIATED WITH SAV-2 SHALL MODULATE OPEN TO PROVIDE 80.0°F SUPPLY AIR TO THE SPACE. UPON SATISFYING THE HEATING SET POINT SAV-2 AND ITS ASSOCIATED HOT WATER CONTROL VALVE SHALL RETURN TO NEUTRAL OPERATION AND THE PERIMETER RADIATION CONTROL VALVE SHALL CLOSE. SEQUENCE OF OPERATION ZONE CONTROL: 180 LAB I CONTROL A.SYSTEM DESCRIPTION 1. 2. 3. SUPPLY AIR VALVE (SAV-1) VARIABLE FUME HOOD EXHAUST AIR VALVE (EAV-EX1) GENERAL EXHAUST AIR VALVE (EAV-8) B.LABORATORY AIRFLOW CONTROL OCCUPIED MODE 1. 2. 3. 4. WHEN THE ROOM IS OCCUPIED, THE ROOM EXHAUST & SUPPLY MIN/MAX RATES SHALL CORRESPOND TO THE LAB AIRFLOW MATRIX VALUES FOR OCCUPIED MODE. THE BACS SHALL SEND AN OCCUPIED COMMAND TO THE FUME HOOD CONTROLLER. THE FUME HOOD CONTROLLER SHALL INDEX THE FUME HOOD SASH POSITION. THE FUME HOOD EXHAUST VALVE (EAV-EX1) CONTROLLER SHALL MODULATE THE EXHAUST VALVE TO MAINTAIN THE REQUIRED 100 FPM FACE VELOCITY SETPOINT BASED ON SASH POSITION. THE GENERAL EXHAUST VALVE (EAV-8) SHALL MODULATE TO MAINTAIN THE OVERALL ROOM AIRFLOW OFFSET BASED ON THE TOTAL ROOM EXHAUST AND SUPPLY AIRFLOW RATES. THE SUPPLY AIR VALVE (SAV-1) SHALL MODULATE BETWEEN ITS MAX & MIN POSITIONS BASED ON THE ROOM TEMPERATURE SETPOINT & REQUIRED AIR FOR EXHAUST OFFSET (REFER TO LAB AIRFLOW MATRIX). THE SUPPLY VALVE SHALL NOT BE ALLOWED TO MODULATE BELOW ITS REQUIRED MINIMUM AIR POSITION FOR THE CURRENT OVERALL ROOM EXHAUST RATE. C.LABORATORY AIRFLOW CONTROL UNOCCUPIED MODE 1. 2. 3. 4. WHEN THE ROOM IS UNOCCUPIED, THE ROOM EXHAUST & SUPPLY MIN/MAX RATES SHALL CORRESPOND TO THE LAB AIRFLOW MATRIX VALUES FOR UNOCCUPIED MODE UNLESS STATED OTHERWISE BELOW. THE FUME HOOD CONTROLLER SHALL INDEX THE FUME HOOD SASH POSITION. IF THE SASH POSITION IS BELOW 18" THE BACS SHALL SEND AN UNOCCUPIED COMMAND TO THE FUME HOOD CONTROLLER. THE FUME HOOD EXHAUST VALVE (EAV-EX1) CONTROLLER SHALL MODULATE THE EXHAUST VALVE TO MAINTAIN THE REQUIRED 80 FPM (ADJUSTABLE) FACE VELOCITY SETPOINT BASED ON SASH POSITION. IF THE SASH POSITION IS ABOVE 18" THE BACS SHALL NOT SEND AN UNOCCUPIED COMMAND TO THE FUME HOOD CONTROLLER. THE FUME HOOD EXHAUST VALVE (EAV-EX1) CONTROLLER SHALL MODULATE THE EXHAUST VALVE TO MAINTAIN THE REQUIRED 100 FPM FACE VELOCITY SETPOINT BASED ON SASH POSITION. THE GENERAL EXHAUST VALVE (EAV-8) SHALL MODULATE TO MAINTAIN THE OVERALL ROOM AIRFLOW OFFSET BASED ON THE TOTAL ROOM EXHAUST AND SUPPLY AIRFLOW RATES. THE SUPPLY AIR VALVE (SAV-1) SHALL MODULATE BETWEEN ITS MAX & MIN POSITIONS BASED ON THE ROOM TEMPERATURE SETPOINT & REQUIRED AIR FOR EXHAUST OFFSET (REFER TO LAB AIRFLOW MATRIX). THE SUPPLY VALVE SHALL NOT BE ALLOWED TO MODULATE BELOW ITS REQUIRED MINIMUM AIR POSITION FOR THE CURRENT OVERALL ROOM EXHAUST RATE. D.LABORATORY AIRFLOW CONTROL HIBERNATION MODE 1.THE ROOM SHALL BE CAPABLE OF BEING MANUALLY SET INTO "HIBERNATION MODE". A LIST OF EQUIPMENT THAT CAN BE TURNED OFF VIA CLOSING BLAST GATES AS WELL AS ANY ADDITIONAL REDUCED AIRFLOW RATES FROM THE UNOCCUPIED MODE SHALL BE PREDETERMINED BY THE FACILITIES ENGINEER AND HEALTH AND SAFETY OFFICER (HSO). THE EXHAUST AIR VALVES SERVING CLOSED OFF EQUIPMENT SHALL BE CLOSED. THE OVERALL ROOM ACH SHALL NOT FALL BELOW 3 ACH AS DETERMINED BY THE HSO. ANY EQUIPMENT DETERMINED NOT TO BE CLOSED DOWN SHALL ENTER INTO UNOCCUPIED MODE. THE SUPPLY AIR VALVE SHALL BE ALLOWED TO RESET DOWN TO ITS HIBERNATION MODE MINIMUM. THE GENERAL EXHAUST VALVE SHALL CONTINUE TO TRACK THE OVERALL ROOM EXHAUST TO MAINTAIN REQUIRED ROOM OFFSET. F.ZONE TEMPERATURE CONTROL 1. 2. 3. WHEN THE SPACE TEMPERATURE SETPOINT IS MET THE SUPPLY AIR VALVE (SAV-1) SHALL MODULATE TOWARDS ITS MINIMUM POSITION BASED ON THE CURRENT ROOM EXHAUST AIRFLOW RATE, THE HOT WATER CONTROL VALVE ASSOCIATED WITH SAV-1 SHALL MODULATE TO MAINTAIN A SUPPLY AIR TEMPERATURE OF 70.0°F TO THE SPACE. THIS SHALL BE CONSIDERED NEUTRAL OPERATION FOR THE SUPPLY VALVE. UPON A CALL FOR COOLING THE HOT WATER CONTROL VALVE ASSOCIATED WITH SAV-1 SHALL CLOSE. IF AFTER A PERIOD OF 15 MINUTES (ADJUSTABLE) THE SPACE IS CALLING FOR ADDITIONAL COOLING THEN THE SUPPLY VALVE SHALL MODULATE TOWARDS ITS MAXIMUM AIRFLOW POSITION. UPON A CALL FOR HEATING THE HOT WATER CONTROL VALVE ASSOCIATED WITH SAV-1 SHALL MODULATE OPEN TO PROVIDE 85.0°F SUPPLY AIR TO THE SPACE. UPON SATISFYING THE HEATING SET POINT SAV-1 AND ITS ASSOCIATED HOT WATER CONTROL VALVE SHALL RETURN TO NEUTRAL OPERATION. SEQUENCE OF OPERATION ZONE CONTROL: 182A PRINT ROOM CONTROL A.SYSTEM DESCRIPTION 1. 2. 3. SUPPLY AIR VALVE (SAV-3) GENERAL EXHAUST AIR VALVE (EAV-2) DEHUMIDIFIER (DH-1) B.LABORATORY AIRFLOW CONTROL 1.THE PRINT ROOM SHALL BE A NEUTRAL PRESSURE AREA AND SHALL BE PROVIDED WITH CONSTANT VOLUME SUPPLY (SAV-3) AND EXHAUST (EAV-2) WITH MULTIPLE OPERATING MODES. DURING DEHUMIDIFICATION MODE THE UNIT SHALL SUPPLY AND EXHAUST 300 CFM. WHEN NOT IN DEHUMIDIFICATION MODE SAV-3 AND EAV-2 SHALL BE ALLOWED TO SETBACK TO THE OCCUPIED AND UNOCCUPIED MINIMUM SUPPLY AIR RATES. REFER TO THE LAB AIRFLOW MATRIX ON SHEET M-501. C.LABORATORY AIRFLOW CONTROL HIBERNATION MODE 1.THE ROOM SHALL BE CAPABLE OF BEING MANUALLY SET INTO "HIBERNATION MODE". A LIST OF EQUIPMENT THAT CAN BE TURNED OFF VIA CLOSING BLAST GATES AS WELL AS ANY ADDITIONAL REDUCED AIRFLOW RATES FROM THE UNOCCUPIED MODE SHALL BE PREDETERMINED BY THE FACILITIES ENGINEER AND HEALTH AND SAFETY OFFICER (HSO). THE EXHAUST AIR VALVES SERVING CLOSED OFF EQUIPMENT SHALL BE CLOSED. THE OVERALL ROOM ACH SHALL NOT FALL BELOW 3 ACH AS DETERMINED BY THE HSO. ANY EQUIPMENT DETERMINED NOT TO BE CLOSED DOWN SHALL ENTER INTO UNOCCUPIED MODE. THE SUPPLY AIR VALVE SHALL BE ALLOWED TO RESET DOWN TO ITS HIBERNATION MODE MINIMUM. THE GENERAL EXHAUST VALVE SHALL CONTINUE TO TRACK THE OVERALL ROOM EXHAUST TO MAINTAIN REQUIRED ROOM OFFSET. F.ZONE TEMPERATURE CONTROL 1. 2. 3. 4. WHEN THE SPACE TEMPERATURE SETPOINT IS MET THE HOT WATER CONTROL VALVE ASSOCIATED WITH SAV-1 SHALL MODULATE TO MAINTAIN A SUPPLY AIR TEMPERATURE OF 70.0°F TO THE SPACE. THIS SHALL BE CONSIDERED NEUTRAL OPERATION FOR THE SUPPLY VALVE. UPON A CALL FOR COOLING THE HOT WATER CONTROL VALVE ASSOCIATED WITH SAV-3 SHALL CLOSE. UPON A CALL FOR HEATING THE HOT WATER CONTROL VALVE ASSOCIATED WITH SAV-3 SHALL MODULATE OPEN TO PROVIDE A 85.0°F LEAVING SUPPLY AIR TO THE SPACE. UPON SATISFYING THE HEATING SET POINT THE HOT WATER CONTROL VALVE SHALL RETURN TO NEUTRAL OPERATION. THE DEHUMIDIFIER (DH-1) SHALL OPERATE INDEPENDENT OF THE TEMPERATURE CONTROLS. UPON THE SPACE HUMIDISTAT RETURNING A RELATIVE HUMIDITY (RH) OF GREATER THAN 40% RH THE DEHUMIDIFIER SHALL BE ENABLED BY THE ROOM HUMIDISTAT AND REMAIN ENABLED UNTIL THE SPACE HAS REACHED A RELATIVE HUMIDITY LEVEL OF 35% RH (ADJUSTABLE) SEQUENCE OF OPERATION ZONE CONTROL: 188 LAB CONTROL A.SYSTEM DESCRIPTION 1. 2. 3. SUPPLY AIR VALVE (SAV-EX1) VARIABLE FUME HOOD EXHAUST AIR VALVE (EAV-EX1) GENERAL EXHAUST AIR VALVE (EAV-EX2) B.LABORATORY AIRFLOW CONTROL OCCUPIED MODE 1. 2. 3. 4. WHEN THE ROOM IS OCCUPIED, THE ROOM EXHAUST & SUPPLY MIN/MAX RATES SHALL CORRESPOND TO THE LAB AIRFLOW MATRIX VALUES FOR OCCUPIED MODE. THE BACS SHALL SEND AN OCCUPIED COMMAND TO THE FUME HOOD CONTROLLER. THE FUME HOOD CONTROLLER SHALL INDEX THE FUME HOOD SASH POSITION. THE FUME HOOD EXHAUST VALVE (EAV-EX1) CONTROLLER SHALL MODULATE THE EXHAUST VALVE TO MAINTAIN THE REQUIRED 100 FPM FACE VELOCITY SETPOINT BASED ON SASH POSITION. THE GENERAL EXHAUST VALVE (EAV-EX2) SHALL MODULATE TO MAINTAIN THE OVERALL ROOM AIRFLOW OFFSET BASED ON THE TOTAL ROOM EXHAUST AND SUPPLY AIRFLOW RATES. THE SUPPLY AIR VALVE (SAV-EX1) SHALL MODULATE BETWEEN ITS MAX & MIN POSITIONS BASED ON THE ROOM TEMPERATURE SETPOINT & REQUIRED AIR FOR EXHAUST OFFSET (REFER TO LAB AIRFLOW MATRIX). THE SUPPLY VALVE SHALL NOT BE ALLOWED TO MODULATE BELOW ITS REQUIRED MINIMUM AIR POSITION FOR THE CURRENT OVERALL ROOM EXHAUST RATE. C.LABORATORY AIRFLOW CONTROL UNOCCUPIED MODE 1. 2. 3. 4. WHEN THE ROOM IS UNOCCUPIED, THE ROOM EXHAUST & SUPPLY MIN/MAX RATES SHALL CORRESPOND TO THE LAB AIRFLOW MATRIX VALUES FOR UNOCCUPIED MODE UNLESS STATED OTHERWISE BELOW. THE FUME HOOD CONTROLLER SHALL INDEX THE FUME HOOD SASH POSITION. IF THE SASH POSITION IS BELOW 18" THE BACS SHALL SEND AN UNOCCUPIED COMMAND TO THE FUME HOOD CONTROLLER. THE FUME HOOD EXHAUST VALVE (EAV-EX1) CONTROLLER SHALL MODULATE THE EXHAUST VALVE TO MAINTAIN THE REQUIRED 80 FPM (ADJUSTABLE) FACE VELOCITY SETPOINT BASED ON SASH POSITION. IF THE SASH POSITION IS ABOVE 18" THE BACS SHALL NOT SEND AN UNOCCUPIED COMMAND TO THE FUME HOOD CONTROLLER. THE FUME HOOD EXHAUST VALVE (EAV-EX1) CONTROLLER SHALL MODULATE THE EXHAUST VALVE TO MAINTAIN THE REQUIRED 100 FPM FACE VELOCITY SETPOINT BASED ON SASH POSITION. THE GENERAL EXHAUST VALVE (EAV-EX2) SHALL MODULATE TO MAINTAIN THE OVERALL ROOM AIRFLOW OFFSET BASED ON THE TOTAL ROOM EXHAUST AND SUPPLY AIRFLOW RATES. THE SUPPLY AIR VALVE (SAV-EX1) SHALL MODULATE BETWEEN ITS MAX & MIN POSITIONS BASED ON THE ROOM TEMPERATURE SETPOINT & REQUIRED AIR FOR EXHAUST OFFSET (REFER TO LAB AIRFLOW MATRIX). THE SUPPLY VALVE SHALL NOT BE ALLOWED TO MODULATE BELOW ITS REQUIRED MINIMUM AIR POSITION FOR THE CURRENT OVERALL ROOM EXHAUST RATE. D.LABORATORY AIRFLOW CONTROL HIBERNATION MODE 1.THE ROOM SHALL BE CAPABLE OF BEING MANUALLY SET INTO "HIBERNATION MODE". A LIST OF EQUIPMENT THAT CAN BE TURNED OFF VIA CLOSING BLAST GATES AS WELL AS ANY ADDITIONAL REDUCED AIRFLOW RATES FROM THE UNOCCUPIED MODE SHALL BE PREDETERMINED BY THE FACILITIES ENGINEER AND HEALTH AND SAFETY OFFICER (HSO). THE EXHAUST AIR VALVES SERVING CLOSED OFF EQUIPMENT SHALL BE CLOSED. THE OVERALL ROOM ACH SHALL NOT FALL BELOW 3 ACH AS DETERMINED BY THE HSO. ANY EQUIPMENT DETERMINED NOT TO BE CLOSED DOWN SHALL ENTER INTO UNOCCUPIED MODE. THE SUPPLY AIR VALVE SHALL BE ALLOWED TO RESET DOWN TO ITS HIBERNATION MODE MINIMUM. THE GENERAL EXHAUST VALVE SHALL CONTINUE TO TRACK THE OVERALL ROOM EXHAUST TO MAINTAIN REQUIRED ROOM OFFSET. F.ZONE TEMPERATURE CONTROL 1. 2. 3. WHEN THE SPACE TEMPERATURE SETPOINT IS MET THE SUPPLY AIR VALVE (SAV-EX1) SHALL MODULATE TOWARDS ITS MINIMUM POSITION BASED ON THE CURRENT ROOM EXHAUST AIRFLOW RATE, THE HOT WATER CONTROL VALVE ASSOCIATED WITH SAV-EX1 SHALL MODULATE TO MAINTAIN A SUPPLY AIR TEMPERATURE OF 70.0°F TO THE SPACE. THIS SHALL BE CONSIDERED NEUTRAL OPERATION FOR THE SUPPLY VALVE. UPON A CALL FOR COOLING THE HOT WATER CONTROL VALVE ASSOCIATED WITH SAV-EX1 SHALL CLOSE. IF AFTER A PERIOD OF 15 MINUTES (ADJUSTABLE) THE SPACE IS CALLING FOR ADDITIONAL COOLING THEN THE SUPPLY VALVE SHALL MODULATE TOWARDS ITS MAXIMUM AIRFLOW POSITION. UPON A CALL FOR HEATING THE SUPPLY AIR VALVE SHALL CONTINUE TO MAINTAIN A SUPPLY AIR TEMPERATURE OF 70.0°F AT ITS MINIMUM POSITION. THE PERIMETER RADIATION HOT WATER CONTROL VALVE SHALL MODULATE OPEN. IF AFTER A PERIOD OF 15 MINUTES (ADJUSTABLE) THE ROOM IS CALLING FOR ADDITIONAL HEATING, THE HOT WATER CONTROL VALVE ASSOCIATED WITH SAV-EX1 SHALL MODULATE OPEN TO PROVIDE 80.0°F SUPPLY AIR TO THE SPACE. UPON SATISFYING THE HEATING SET POINT SAV-EX1 AND ITS ASSOCIATED HOT WATER CONTROL VALVE SHALL RETURN TO NEUTRAL OPERATION AND THE PERIMETER RADIATION CONTROL VALVE SHALL CLOSE. ROOM AREA (SQUARE FEET)X XX XX X X X X X X X TOTAL OCCUPIED EXHAUST AIRFLOW SETPOINT (CFM), MAXIMUM X LABORATORY AIR CHANGE RATE (ACH), ACTUAL XX LABORATORY FLOW OFFSET (CFM), ACTUAL XX XX TOTAL EXHAUST AIRFLOW (CFM), ACTUAL XX TOTAL SUPPLY AIRFLOW (CFM), ACTUAL TOTAL OCCUPIED EXHAUST AIRFLOW SETPOINT (CFM), MINIMUM TOTAL UNOCCUPIED EXHAUST AIRFLOW SETPOINT (CFM), MAXIMUM TOTAL UNOCCUPIED EXHAUST AIRFLOW SETPOINT (CFM), MINIMUM TOTAL OCCUPIED SUPPLY AIRFLOW SETPOINT (CFM), MAXIMUM TOTAL OCCUPIED SUPPLY AIRFLOW SETPOINT (CFM), MINIMUM TOTAL UNOCCUPIED SUPPLY AIRFLOW SETPOINT (CFM), MAXIMUM TOTAL UNOCCUPIED SUPPLY AIRFLOW SETPOINT (CFM), MINIMUM LABORATORY AIR CHANGE RATE SETPOINT (ACH), MAXIMUM LABORATORY AIR CHANGE RATE SETPOINT (ACH), MINIMUM ROOM CEILING HEIGHT (FEET)X THE EXISTING LAB CONTROLS SHALL REMAIN. THE BELOW SEQUENCES ARE PROVIDED AS REFERENCE. INTERLOCK WITH FUME HOOD EXHAUST VALVE FUME HOOD FACE VELOCITY (FPM)XX FUME HOOD FACE VELOCITY SETPOINT (FPM)XX X BELOW SETPOINT FOR > 10 SEC. (ADJUSTABLE) DEHUMIDIFIER (D-1) ENABLE/DISABLE XXX DEHUMIDIFIER (D-1) STATUS XXX GAS DETECTION HIGH LIMIT (EAV-3)XXX X X X X X X X X X X X X X X X HIGH LIMIT SPACE HUMIDITY SETPOINT (DEG F)XX SPACE HUMIDITY (DEG F)X X X 182 PRINT ROOM ONLY MONITORING IN ALL SPACESX X X X X CO & CH4 CABINETS D.VENTILATION SYSTEM EMERGENCY SHUTOFF 1.A MANUAL SHUTOFF CONTROL BUTTON SHALL BE PROVIDED OUTSIDE THE ROOM ADJACENT TO THE ACCESS DOOR. THE SWITCH SHALL BE A BREAK GLASS TYPE. WHEN THIS MANUAL EMERGENCY CONTROL SWITCH IS ACTIVATED, ALL AIR VALVES ASSOCIATED WITH THE LABORATORY SHALL BE COMMANDED INTO THEIR CLOSED POSITION. 1 Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 6, 2020 12" = 1'-0" Flow & Control -Mechanical M-401 ALL EXISTING CONTROL POINTS INDICATED ABOVE SHALL BE TRANSFERRED OVER TO THE NEW ALC PANEL. 1 1 AO LINE TYPE LEGEND NEW WORK EXISTING TO REMAIN VFD CSR 95%finalfilter30%pre-filterP DP SP ~ LT ~M ~RETURN AIR SD SP AI TO VAVS TO VAVS T GLYCOL PREHEAT COIL CHILLED WATER COOLING COIL AO T AI AO A DI T AI AO T AIDI DI DOAO AI A DI AI RETURN AIR DAMPER COMMAND DI DO AI AO AV BV SCH TREND BAS SOFTWARE POINTSHARDWARE POINTS ALARM DESCRIPTION SHOWN ON GRAPHIC NOTESVARIABLE AIR VOLUME AIR HANDLING UNIT (AHU-2) OUTSIDE AIR DAMPER COMMAND RETURN AIRFLOW MEASURING STATION THE POINTS LISTED BELOW ARE EXISTING TO AHU-2. THE SENSORS AND DEVICES SHALL REMAIN. THE CONTROL POINTS SHALL BE MOVED TO THE NEW ALC PANEL. X X X X X X X OUTSIDE AIRFLOW MEASURING STATION X X X CHILLED WATER COIL VALVES AHU-2 VARIABLE SPEED DRIVE X X X X X XX X XX 1 SCALE: NONE OUTSIDE AIR M AFMSAI M-402M-402 GENERAL NOTES: 1. 2. 3. 4. AIR HANDLING UNIT (AHU-2) IS EXISTING UNIT TO REMAIN. CONTROL DEVICES AND SENSORS SHOWN IN GRAYSCALE ARE EXISTING TO REMAIN. CONTROL DEVICES AND SENSORS SHOWN IN DARKER LINE TYPE ARE TO BE REPLACED OR PROVIDED NEW. ALL CONTROL POINTS SHALL BE MOVED OVER TO THE NEW AUTOMATED LOGIC CONTROL PANEL. NEW AIR FLOW MEASURING STATION EXISTING AHU-2 SHALL BE MODIFIED TO INCLUDE A OUTSIDE AIR DAMPER, RETURN AIR DAMPER, AND AIRFLOW MEASURING STATIONS ON OA & RA. EXISTING VARIABLE VOLUME AIR HANDLING UNIT (AHU-2) AO CONNECT NEW RA DUCT TO EXISTING AHU-2 FLANGE CUT IN NEW OA MOTORIZED DAMPER TO EXISTING OA DUCTWORK. PROVIDEWITH AIR FLOWMEASURING STATION GLYCOL PREHEAT COIL VALVES X X X GLYCOL TEMPERATURE X X X CHILLED WATER TEMPERATURE X X X FILTER DIFFERENTIAL PRESSURE X X X DISCHARGE AIR TEMPERATURE X X X SUPPLY FAN START/STOP X X X AHU-2 SYSTEM SHUTDOWN X X X SUPPLY FAN VARIABLE SPEED DRIVE ALARM X X X CHILLED WATER COIL FREEZE STAT X X X SUPPLY FAN CURRENT SENSOR RELAY X X X X X LOW TEMPERATURE FAILURE GLYCOL PREHEAT COIL AIR TEMPERATURE X X X CHILLED WATER COIL AIR TEMPERATURE X X X DISCHARGE STATIC PRESSURE X X X DUCT STATIC PRESSURE SENSOR XXX SEQUENCE OF OPERATION EXISTING AIR HANDLING UNIT AHU-2 A.GENERAL 1. 2. 3. 4. 5. 6. SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION SYSTEM (BAS). ALL SET POINTS SHALL BE ADJUSTABLE. THE BAS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM FOR SEVEN DIFFERENT DAILY SCHEDULES PER WEEK. THE BAS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. ALL SAFETIES SHALL BE HARD WIRED INTO THE FAN MOTOR POWER CIRCUIT, AND SHALL REQUIRE MANUAL RESET. DESIGN INTENT: THE AIR HANDLING UNIT IS PROVIDING HEATING, COOLING, AND POSITIVE PRESSURIZATION FOR THE SPACES SERVED. AIRFLOW CONTROL DEVICES WITH REHEAT COILS SHALL BE PROVIDED ON THE ZONE SUPPLY CONNECTIONS. B.DISABLED MODE 1.WHEN THE UNIT IS DISABLED, THE SUPPLY FANS SHALL BE OFF, THE OUTSIDE AIR DAMPER SHALL BE CLOSED, THE RETURN DAMPER SHALL BE OPEN, AND THE COOLING COIL CONTROL VALVES SHALL BE CLOSED. THE GLYCOL PREHEAT COIL SHALL REMAIN AVAILABLE FOR SIGNAL FROM THE CHILLED WATER COIL FREEZE STAT. C.NORMAL OPERATING MODE 1. 2. 3. 4. SUPPLY AIR FAN SHALL MODULATE VIA A VARIABLE FREQUENCY DRIVE AS REQUIRED TO MAINTAIN THE SUPPLY DUCT STATIC PRESSURE SET POINT. THE SUPPLY DUCT STATIC PRESSURE SET POINT SHALL BE RESET AS NEEDED TO MAINTAIN THE CRITICAL ZONE DAMPER POSITION AT 95% OPEN. COOLING MODE: WHEN DISCHARGE AIR TEMPERATURE RISES ABOVE SETPOINT, COOLING MODE SHALL BE INITIATED. THE CHILLED WATER CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SET POINT. DISCHARGE AIR TEMPERATURE (DAT) RESET: THE DISCHARGE AIR TEMPERATURE SHALL BE ALLOWED TO RESET BASED ON AN AVERAGE SPACE TEMPERATURE OF THE ASSOCIATED VAV ZONES. WHEN THE AVERAGE ZONE TEMPERATURE IS BELOW THE SETPOINT FOR A PERIOD OF 15 MINUTES (ADJUSTABLE) THE DAT SHALL BE ALLOWED TO RESET UP TO 65°F. UPON A CALL FOR COOLING IN ANY ZONE FOR A PERIOD GREATER THAN 15 MINUTES (ADJUSTABLE) THE DAT SHALL RETURN TO A 55°F SETPOINT. DEHUMIDIFICATION MODE: THE ZONE HUMIDITY LEVELS SHALL BE MONITORED BY THE BMS. IF AT ANY TIME A ZONE HUMIDITY LEVEL RISES ABOVE 60% RH (ADJUSTABLE) THE DAT RESET SHALL BE OVERRIDDEN AND THE DAT SETPOINT SHALL RETURN TO 55°F. D.MORNING WARM UP 1.THE OUTSIDE AIR DAMPER SHALL REMAIN OPEN TO SATISFY ROOM PRESSURIZATION REQUIREMENTS. THE SPACE TEMPERATURE SENSOR SET POINT SHALL BE THE SAME AS DURING NORMAL OPERATING MODE. THE DAT SHALL RESET TO 65°F. THE ZONE VAVs SHALL OPEN TO THEIR MAXIMUM AIRFLOWS AND REMAIN OPEN UNTIL THE SPACE TEMPERATURE SETPOINT IS SATISFIED. THE HOT WATER CONTROL VALVE SHALL MODULATE TO ITS FULL OPEN POSITION. UPON REACHING THE SPACE TEMPERATURE SETPOINT, NORMAL MODE SHALL RESUME. E.VENTILATION CONTROL 1. 2. THE OUTSIDE AIR DAMPER AND THE RETURN AIR DAMPER SHALL MODULATE BASED ON THE OUTSIDE AIR DAMPER AFMS TO MAINTAIN PRESSURIZATION. THE AIR FLOW SET POINT OF 300 CFM SHALL BE ESTABLISHED DURING SYSTEM AIR BALANCING AND SHALL BE MONITORED BY THE OUTSIDE AIR DAMPER AFMS. THE GLYCOL PREHEAT COIL SHALL MODULATE TO MAINTAIN MINIMUM DISCHARGE AIR TEMPERATURE TO THE COOLING COIL 48 °F (ADJUSTABLE). F.SAFETIES AND ALARMS 1. 2. 3. 4. 5. 6. A FREEZESTAT LOCATED UPSTREAM OF THE CHILLED WATER COIL SHALL SIGNAL THE GLYCOL COIL CONTROL VALVE TO MODULATE TO ITS FULL OPEN POSITION WHEN THE AIR TEMPERATURE SENSED ON ANY SEGMENT OF THE SERPENTINE SENSING ELEMENT HAS DROPPED BELOW 40°F (ADJUSTABLE). IF AFTER A PERIOD OF 5 MINUTES (ADJUSTABLE) THE FREEZE STAT IS STILL SENSING ANY POINTS BELOW 40°F AN ADDITIONAL ALARM SHALL BE SIGNALED AND THE BACS SHALL CLOSE THE OUTSIDE AIR DAMPER . AT THE SAME TIME THE RETURN AIR DAMPER SHALL FULLY OPEN. THE FREEZESTAT SHALL BE RESET WITH ITS OWN MANUAL RESET BUTTON. UPON ACTIVATION OF THE SUPPLY OR RETURN AIR SMOKE DETECTORS, THE SUPPLY FAN SHALL SHUT DOWN WITH THE HOA SWITCH IN BOTH THE HAND AND AUTO POSITIONS, AND THE OUTSIDE AIR DAMPER SHALL CLOSE. THE FIRE ALARM SYSTEM SHALL BE WIRED DIRECTLY TO THE FAN START CIRCUIT. SMOKE DETECTORS SHALL BE FURNISHED BY DIVISION 26, INSTALLED IN THE DUCTWORK WHERE INDICATED BY DIVISION 23, AND WIRED TO THE FIRE ALARM SYSTEM BY DIVISION 26. THE SUPPLY AIR STATIC PRESSURE SENSOR SHALL SHUT DOWN THE SUPPLY FANS WHEN THE DUCT STATIC PRESSURE EXCEEDS 3" W.C. (ADJUSTABLE). WHEN THE FAN IS SHUT DOWN, AN ALARM SHALL BE INITIATED. THE DDC CONTROL SYSTEM SHALL MONITOR THE STATUS OF THE SUPPLY FAN VIA THE CURRENT SENSOR. IF ANYTIME THE SUPPLY FAN IS ENABLED AND AFTER A 20 SECOND DELAY THE CONTROL SYSTEM SENSES NO CURRENT, THE SUPPLY FAN SHALL BE TURNED OFF AND AN ALARM SHALL BE INITIATED ON THE BAS. THE CONTROL SYSTEM SHALL MONITOR THE DISCHARGE AIR TEMPERATURE VIA A TEMPERATURE SENSOR LOCATED IN THE SUPPLY DUCT. IF THE DISCHARGE AIR TEMPERATURE DEVIATES MORE THAN 5 F ABOVE OR BELOW THE SETPOINT FOR A PERIOD OF 5 MINUTES WHILE THE UNIT IS ENABLED, AN ALARM SHALL BE INITIATED ON THE BAS. FOLLOWING A SAFETY SHUT-DOWN, A MANUALLY INITIATED RESTART COMMAND SHALL RESTART THE SYSTEM AS PREVIOUSLY DESCRIBED UNDER NORMAL OPERATING MODE. 1 Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 6, 2020 12" = 1'-0" Flow & Control -Mechanical M-402 REF. 012345678 9 A B D C E F 012345678 9 A B D C E F BB ETR: 3/4"CA UP&DN 3/4"HWR UP&DN 1 1/2"CW UP&DN 1"HW UP&DN 1 1/4"G UP&DN ETR 4"AW UP&DN (VIF) 182 SADAF'S LAB 754 181 LAB I 597 184 STUDENT SPACE 563 CTE 1 1/2"W FROM PVC DRAIN ABOVE NEW 2" W DN SK 2"W DN 1 1/2"V RISE 1/2"H&CW DROP SK 2"W DN 1 1/2"V RISE 1/2"H&CW DROP NEW SINK 2"W DN 1 1/2"V RISE 3/4"H&CW DROP CONN. NEW VENT & WATER TO EXIST. CONN. NEW VENT & WATER TO EXIST. OPTICAL TABLE OPTICAL TABLE CH4 CYLINDERS INSIDE GAS CABINET (BY OTHER DIV.) SHAFT 905 Room 10 NEW ES/EW, TMV IN RECESSED BOX W/ 1"C&HW SUPPLIES. 1 1/4"TEMPERED WATER @ 65-90 °F SUPPLY TO ES/EW. TYP. FOR ALL EW/SH. CTE: 3/4"CA 1 1/2"HW 1 1/2"CW EX.FD WITH NEW DRAIN GRATE 3/4"CA DROP TO FUMEHOOD ES/EW ES/EW ES/EW 2"V CTE VENT STACK 3/4"CA DROP TO FUMEHOOD 3/4"CA 1"CW 1/2"HWC EX. PLUMBING SERVICES TO REMAIN. RUN @ CEILING EX.FD NEW DRAIN GRATE 3/4"CA DROP TO EQUIP. 1/2"CH4 DROP TO EQUIP. 1"HW 1/2"CH4,CA,Kr DROP INTO UTILITY CHANNEL TO NOZZLES. TYP. ETR 4"ST UP&DN PROVIDE NEW INSULATION AND SOUND LAGGING EX.4"ST UP&DN PROVIDE NEW INSULATION AND SOUND LAGGING 3/4"HW3/4"CW 1 1/2"W 1"CW 1"HW 3/4"CW 1"CA1"HW11/2"CW1"CW 3/4"CA 1"CW 3/4"CA 1"HW 1"CA 1"HW2 1/2"AW 1 1/2"CW 1/2"CA3/4"CW2"WEX. 1 1/4"G CAPPED ETR 4"S DROP&OFFSET UP ETR 4"S UP ETR 4"S DN 3"S ETR 3"W UP ETR 1"W UP 1"CW 1"C&HW CTE ETR CW&CA DN ETR HW CAPPED ETR CW&CA UP ETR CW INTO WALL ETR C&HW DROP ETR: CW,HW, CA ETR 2"W DN ETR: 2"W UP 3/4"CW UP 3/4"CA UP ETR 1 1/2"W UP 1 1/2"W 3/4"CA 1/2"Kr 1/2"CH43/4"CACO ETR 2 1/2"AW UP ETR 1 1/2"AW UP 2 1/2"AW 3/4"CW 3/4"HW 1"HW 1 1/4"CW 1 1/2"CW 1"HW 188 495 188A 439 100CB CORRIDOR 207 100TC 93 10048 551 187 101 189 99 191 151 193 257 100CA COMMON AREA 442 182A PRINT ROOM 76 3/4"C&HW UP 1"TW UP 3"FD MV2MV2 1 1/2"V CTE 1/2"CH4 RISE FROM MANIFOLD 1/2"Kr RISE FROM WALL-MOUNT TANK1"HW1/2"HWR CTE 1/2"CH4 VALVE & CAP OUTLET FOR FUTURE USE 1/2"CH4 1/2"CH4 1 GENERAL PLAN NOTES CONTRACTOR TO COORDINATE GAS DETECTOR LOCATIONS WITH OWNER. 2 CA CONNNECTIONS TO ADJUSTIBLE TABLES REQUIRE FLEX CONNECTIONSALLOWING UP TO 6" OF VERTICAL TRAVEL. MV2 3/4"HW 1/2"HWC 3/4"CW 3/4"CA 1"C&HW DROP 1"TW RISE 1/2"CA DROP TO GAS CABINET1/2"CA 1 1 Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 1/4" = 1'-0" FIRST FLOOR-Plumbing P-102 1/4" = 1'-0"1 FIRST FLOOR EXIST. PLUMBING SERVICES TO REMAIN Addendum 1 May 6, 2020 CH4 FLAMMABLE GAS CABINET PIPING SCHEMATIC SCALE: NONE 1 P-300P-300 CH4 0-125PSIG 0-2000PSIG 0-125PSIG0-125PSIG MANUAL VALVE EXCESS FLOW VALVE FLASHBACK ARRESTOR DUCT AIRFLOW SWITCH WITHVISUAL INDICATOR EXHAUST AIR TOCABINET AIRVALVE SHUTDOWN CONTROLLER EGO 1/4" CH4 1/2" CH4 KEYED CONSTRUCTION NOTES 3-CYLINDER GAS CABINET (GC-1) WITH AUTOMATIC PNEUMATIC EMERGENCY SHUTOFF VALVE PROVIDE RELAY BASED SHUTDOWN CONTROLLER AND TWO 0-100% LEL DETECTORS FOR METHANE. SHUTDOWN CONTROLLER TO INCLUDE MANUAL EMERGENCY STOP BUTTON AND MONITORING GAS DETECTORS THAT SHALL COMMAND SHUT THE PNEUMATIC VALVES IN THE EVENT OF A LEAK. 30-INCH OF STAINLESS STEEL FLEX HOSE OR PIG-TAIL TO BE INSTALLED ON REGULATOR INLET WITH CGA 350 CONNECTION ON THE CYLINDERS, WITH INTEGRAL CHECK VALVE NIPPLE. PNEUMATIC EMERGENCY SHUTOFF VALVE (ESO) CONNECTED TO 90 PSIG HOUSE COMPRESSED AIR SERVICE. PROVIDE AIRFLOW PRESSURE SWITCH/GAGE WITH TWO DPDT CONTACT RELAYS AND FACE MOUNTED ADJUSTABLE SETPOINT KNOBS. WIRE TO GAS CABINET SHUTDOWN CONTROLLER . SEE DETAIL 1/M-406 FOR ADDITIONAL INFORMATION. BASIS OF DESIGN, DWYER A3002. 1/2" NPT CONNECTION WITH SPRINKLER PROVIDED WITH GAS CABINET. REMOVE SPRINKLER AND CAP OPENING. TURN OVER SPRINKLER TO OWNER FOR FUTURE USE. GAS PIPING SHALL RUN EXPOSED WITHIN THE SPACE. PROVIDE UNI-STRUT WITH CUSHION CLAMPS FOR ALL GAS PIPING SUPPORTS. INSTALL SERVICE DROP DIRECTLY TO WALL. PROVIDE UNI-STRUT WITH CUSHION CLAMPS FOR ALL GAS PIPING SUPPORTS. GAS SERVICE TO EQUIPMENT. PROVIDE SWAGE TUBE FITTING. FINAL CONNECTION TO EQUIPMENT BY RESEARCHER. 1 2 3 4 5 6 7 8 9 1 GENERAL CONSTRUCTION NOTES THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO FORM A COMPLETE FUNCTIONING SYSTEM. ITEMS NOT SPECIFICALLY MENTIONED, BUT WHICH ARE INHERENTLY NECESSARY TO MAKE A COMPLETE WORKING INSTALLATION SHALL BE PROVIDED. THE FOLLOWING COMPONENTS ARE TO BE PROVIDED BY OTHERS. THEY ARE SHOWN FOR INFORMATION AND COORDINATION PURPOSES ONLY. - GAS CYLINDERS. - GAS CYLINDERS VALVES. - REDUCED FLOW ORIFICES. THE GAS CABINET SHALL BE PROVIDED AS: AIRGAS - MODEL: LAB 1000 CUSTOM 48" WIDE x 18" DEEP x 72" TALL CABINET CONSTRUCTED TO NFPA 55 STANDARDS, AND SHALL BE PROVIDED WITH THE FOLLOWING: SEMI AUTIMATIC CHANGEOVER MANIFOLD w/ 0-125 PSIG MAX DELIVERY PRESSURE RANGE. - (2) 36" FLEXIBLE STAINLESS STEEL PIGTAILS WITH CGA CONNECTIONS WITH CHECK NIPPLE AND SHUTOFF VALVE. - PNEUMATIC SHUTOFF VALVES ON INLET SIDES OF MANIFOLD. - EXCESS FLOW VALVE AND FLASHBACK ARRESTOR MOUNTED ON OUTLET SIDE OF MANIFOLD. INDIVIDUAL REGULATOR FOR ADDITIONAL FLAMMABLE GAS CYLINDER. - 36" FLEXIBLE STAINLESS STEEL PIGTAILS WITH CGA CONNECTIONS WITH CHECK NIPPLE AND SHUTOFF VALVE. - PNEUMATIC SHUTOFF VALVE. - EXCESS FLOW VALVE AND FLASHBACK ARRESTOR MOUNTED ON OUTLET SIDE OF MANIFOLD. - TWO 0-100% LEL GAS DETECTORS (1) FOR LEAK DETECTION AT EXHAUST & (1) FOR AMBIENT LEAK DETECTION AT POINT OF USE. - DIFFERENTIAL PRESSURE SWITCH: 0-0.5" WG RANGE, TAMPER PROOF KNOBS, 120 VAC. - CABINET SHUTDOWN CONTROLLER TO PNEUMATIC VALVE SHUTOFF. - ONBOARD EMERGENCY STOP BUTTON. 1.0 2.0 3.0 FLAMMABLE GAS PIPING SCHEDULE TAG CH4 DESCRIPTION MATERIAL METHANE ASTM A269 316L STAINLESS STEEL FITTINGS ASTM A162 316L STAINLESS STEEL JOINTS ORBITAL WELD NOTES: 1.ALL PIPING SHALL BE MANUFACTURER CLEANED, PURGED, AND SEALED ACCORDING TO CGA G-4.1 OR SWAGELOCK SC-11 FOR OXYGEN SERVICE. SEE SECTION 220000 FOR FURTHER DETAILS. 2 3 3 44 5 6 77 1/4" CH48 1/4" CH48 9 9 MANUAL VALVE MANUAL VALVE 1 CH4 FINAL CH4 GAS CONNECTION TO OPTICAL TABLEEQUIPMENT BYRESEARCHER 0-125PSIG 1/2" CH47 1/4" CH48 9 MANUAL VALVE 0-125PSIG 1/2" CH47 1/4" CH48 9 MANUAL VALVE FINAL CH4 GAS CONNECTION TO OPTICAL TABLEEQUIPMENT BYRESEARCHER FINAL CH4 GAS CONNECTION TO OPTICAL TABLEEQUIPMENT BYRESEARCHER FINAL CH4 GAS CONNECTION TO OPTICAL TABLEEQUIPMENT BYRESEARCHER OTHERFLAMMABLE GAS 3 4 AUTOMATIC CHANGEOVERMANIFOLD 1/4" CH48 MANUAL VALVE CH4 GAS WITH ISOLATION VALVE AND CAP TO LAB 188 FORFUTURECONNECTION. 1/2" CH47 MANUAL VALVE 0-125 PSIG 0-2000 PSIG MANUAL VALVE EXCESSFLOW VALVEFLASHBACKARRESTOR MANUAL VALVE 2 CH4 AMBIENT GAS DETECTOR. INTALL IN SPACE PER MANFUCATURER'SGUIDELINES. 3-CYLINDER GAS CABINETDETECTOR SHIPPED LOOSEINSTALLED IN GAS CABINET. 1 1 KRYPTON GAS PIPING SCHEMATIC SCALE: NONE 2 P-300P-300 Kr KEYED CONSTRUCTION NOTES PROVIDE CYLINDER RACK BARRICADE TYPE WITH 2-INCH SQUARE STEEL TUBE CONTINUOUSLY WELDED SEAM WITH POWDER COATED FINISH; TWO LEVELS OF WELDED STEEL SHAINS, CYLINDER SNAP, PRE-DRILLED HOLES FOR MOUNTING TO FLOOR, AND STRAPS TO PROPERLY SECURE CYLINDERS. BASIS OF DESIGN USA SAFTEY MODEL BR4X1FS. PROVIDE 30-INCH STAINLESS STEEL FLEX HOSE OR PIG-TAIL CONNECTION TO CYLINDERS. INSTALL ALL REGULATORS AND MANUAL SHUTOFF VALVES ON PANEL MOUNTED TO WALL. GAS PIPING SHALL RUN EXPOSED WITHIN THE SPACE. PROVIDE UNI-STRUT WITH CUSHION CLAMPS FOR ALL GAS PIPING SUPPORTS. INSTALL SERVICE DROP DIRECTLY TO WALL. PROVIDE UNI-STRUT WITH CUSHION CLAMPS FOR ALL GAS PIPING SUPPORTS. GAS SERVICE TO EXPERIMENT. PROVIDE SWAGE TUBE FITTING. FINAL CONNECTION TO EQUIPMENT BY RESEARCHER. MOUNT AT 4-FEET ABOVE FINISHED FLOOR. 1 2 3 4 5 6 1 GENERAL CONSTRUCTION NOTES THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO FORM A COMPLETE FUNCTIONING SYSTEM. ITEMS NOT SPECIFICALLY MENTIONED, BUT WHICH ARE INHERENTLY NECESSARY TO MAKE A COMPLETE WORKING INSTALLATION SHALL BE PROVIDED. THE FOLLOWING COMPONENTS ARE TO BE PROVIDED BY OTHERS. THEY ARE SHOWN FOR INFORMATION AND COORDINATION PURPOSES ONLY. - GAS CYLINDERS. - GAS CYLINDERS VALVES. - REDUCED FLOW ORIFICES. THE KRYPTON GAS CYLINDER SHALL BE SECURELY FASHIONED TO THE STRUCTURE. REFER TO CORNELL STANDARDS FOR GAS CYLINDER INSTALLATION. THE CYLINDER PIPING SHALL BE PROVIDED WITH THE FOLLOWING. - 36" FLEXIBLE STAINLESS STEEL PIGTAILS WITH CGA CONNECTIONS WITH CHECK NIPPLE AND SHUTOFF VALVE. - AIRGAS SINGLE STAGE STAINLESS STEEL REGULATOR MODEL EMD-400. PRESSURE RANGE AND MOUNTING TYPE TO BE COORDINATED WITH FINALIZED OPTICAL TABLE REQUIREMENTS. 1.0 2.0 PROCESS GAS PIPING SCHEDULE TAG Kr DESCRIPTION MATERIAL KRYPTON ASTM A269 316L STAINLESS STEEL FITTINGS ALT JOINTS ORBITAL WELD, BENDS NOTES: 1.ALL PIPING SHALL BE MANUFACTURER CLEANED, PURGED, AND SEALED ACCORDING TO CGA G-4.1 OR SWAGELOCK SC-11 FOR OXYGEN SERVICE. SEE SECTION 220000 FOR FURTHER DETAILS. 2 0-100PSIG 0-1400PSIG 0-100 PSIG 0-XX PSIG 6 MANUALVALVE 200 SCFCGA 580 3 1/2" Kr4 1/4" Kr4 1/4" Kr5 Kr OUTLET1/4" SWAGE ASTM A162 316L STAINLESS STEEL 1/2" Kr4 GAS SERVICES TO OPTICAL TABLE 0-100 PSIG 0-XX PSIG 6 1/4" Kr5 Kr OUTLET1/4" SWAGE GAS SERVICES TO OPTICAL TABLE 0-100 PSIG 0-XX PSIG 6 1/4" Kr5 Kr OUTLET1/4" SWAGE GAS SERVICES TO OPTICAL TABLE 0-100 PSIG 0-XX PSIG 6 1/4" Kr5 Kr OUTLET1/4" SWAGE GAS SERVICES TO OPTICAL TABLE 1/2" Kr4 Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 6, 2020 12" = 1'-0" Gas Piping Schematic Details 1 Plumbing P-300 GAS DETECTION & SHUTDOWN CONTROLLER SCHEMATIC SCALE: NONE 1 P-301P-301 2 CH4 1 CH4 SHUTDOWN CONTROLLERSPARE SHUTDOWN CONTROLLERSPARE SHUTDOWN CONTROLLERSPARE SHUTDOWN CONTROLLERSPARE SHUTDOWN CONTROLLERSPARE SHUTDOWN CONTROLLERSPARE SHUTDOWN CONTROLLERSPARE SHUTDOWN CONTROLLERSPARE SHUTDOWN CONTROLLERSPARE SHUTDOWN CONTROLLERSPARE SHUTDOWN CONTROLLERSPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE COMMON RELAY TO SHUTDOWN CONTROLLERS FIRE ALARM MONITORING TO BACS 120 VAC 16 CHANNEL GAS DETECTION CONTROLLER 120 VAC 1 CH4 INPUTS OUTPUTS VENT SHUTDOWN CONTROLLER FLAMMABLE GAS CABINET P S CH4CH4 AMM COORDINATE WITH THE ELECTRICAL CONTRACTOR A TIE-IN TO THE NEAREST FIRE ALARM CONTROLLER AND PROVIDE PROVISION OF ADDRESSIBLE MONITOR MODULE . 80-100 PSIG HOUSE COMPRESSED AIR TAG 2/CH4 DEVICE LOCATION MONITOR ZONE NOTES NOTES: 1. 2. ALL PIPING SHALL BE MANUFACTURER CLEANED, PURGED, AND SEALED ACCORDING TO CGA G-4.1 OR SWAGELOCK SC-11 FOR OXYGEN SERVICE. GAS DETECTORS SHALL BE SHIPPED LOOSE AND INSTALLED BY THE CONTRACTOR IN THE 3-CYLINDER GAS CABINET AND IN THE SPACE 182 SADAF'S LAB. THE DETECTORS SHALL BE INSTALLED PER THE MANUFACTURER'S GUIDELINES. LEL % TRIGGER SET POINT 10% LEL 0.51/CH4 GAS DETECTOR 182 SADAF'S LAB FLAMABLE GAS CABINET 0-100% LEL METHANE DETECTOR5 0.5GAS DETECTOR AMBIENT 0-100% LEL METHANE DETECTOR5182 SADAF'S LAB EXHAUST PRESSURESWITCH SHUTDOWN CONTROLLERSPARE SHUTDOWN CONTROLLERSPARE SHUTDOWN CONTROLLERSPARE CH4 GAS DETECTOR SHIPPED LOOSE ANDINSTALLED IN 3-CYLINDER GAS CABINET. 1 1 Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 6, 2020 12" = 1'-0" Gas Detection Shutdown Controller Schematic -Plumbing P-301 N.T.S. PIPE PENETRATION WITH SLEEVE RISER CLAMP FIRE PROOF CAULK (TYP.)FLOOR ANCHOR COLLAR SCH. 40 GALV. STEEL PIPE SLEEVE (1" O.D.) LARGER THAN PIPE INSULATION CONC. FLOOR SLAB OR FLOOR CONSTRUCTION 1 -- FIRE STOPPING SHALL HAVE F-RATING & T-RATED EQUAL TO OR GREATER THAN THE FLOOR BEING PENETRATED -SEE 260500. REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR RATINGS AND LOCATIONS. NOTE: DRYWALL PARTITION FIRESTOP SEALANT SCHEDULE 40 GALVANIZED PIPE SLEEVE GROUT SLEEVE IN MASONRY WALL FIRE SEALANT PER 260000 CONCRETE/MASONRY WALL NOTE:FIRE STOPPING SHALL HAVE A RATING EQUAL TO OR GREATER THAN THE WALL BEING PENETRATED -SEE 260000. REFER TO ARCHITECTURAL DRAWINGS FOR WALL RATINGS AND LOCATIONS. SCALE: NONE FIRE-RATED WALL PENETRATION2 -- ELECTRICAL SYMBOLS EXIT LIGHT CEILING MOUNTED, ( ARROWS AS INDICATED ) SINGLE CONVENIENCE RECEPTACLE-16"AFF U.O.N. DUPLEX CONVENIENCE RECEPTACLE-16"AFF U.O.N. DOUBLE DUPLEX CONVENIENCE RECEPTACLE-16"AFF U.O.N. EMS RECEPTACLE (ENERGY MGMT SYSTEM-CONTROLLED)-16"AFF U.O.N. GROUND FAULT INTERRUPTING RECEPTACLE-16"AFF U.O.N. SPECIAL OUTLET CONFIGURATION-SEE NEMA # J WALL MOUNTED JUNCTION BOX J CEILING MOUNTED JUNCTION BOX CEILING MOUNTED DUPLEX RECEPTACLE SINGLE POLE SWITCH -48"AFF U.O.N.S LOCKABLE SINGLE POLE SWITCH. B.O.D: BRADY PART # 65392LOCKS DIMMER ( SWITCH ) OR CONTROL-48"AFF U.O.N.DS OCOCCUPANCY SENSOR SWITCH-1 WAY -CEILING MOUNTED OCCUPANCY SENSOR SWITCH-WALL MOUNTED -48"AFF U.O.N.OS POWER OR LIGHTING PANEL DISCONNECT SWITCH (SWITCH SIZE/FUSE SIZE; NF = NON-FUSED)30/20 MOTOR LOCATION COMBINATION MOTOR STARTER / MOTOR CIRCUIT PROTECTOR LOCATION VARIABLE FREQUENCY DRIVE / VARIABLE SPEED CONTROLLER MISCELLANEOUS CONTROL PANEL WP WEATHERPROOF CONDUITC CH DEVICE MOUNTED ABOVE/AT COUNTER HEIGHT EXISTING EQUIPMENT TO REMAIN (EX) EXISTING EQUIPMENT TO BE REMOVED EXISTING DEVICE TO REMAINE NEW DEVICE IN EXISTING LOCATIONN REPLACE EXISTING DEVICE WITH NEWR REMOVE EXISTING DEVICE AND PATCHP REMOVE EXISTING DEVICEX RELOCATED POSITION OF EXISTING DEVICEL FLOOR BOX WITH COMMUNICATIONS OUTLET EQUIPMENT / OUTLET CONTROL GROUP WIRING UNSWITCHED BRANCH CIRCUIT WIRING LP/#HOMERUN TO PANEL (LP = PANEL NAME; # = CIRCUIT #) CEILING-MOUNTED WIRELESS ACCESS POINTWAP R RELAY OR CONTACTOR FOR CONTROL LINEAR LIGHTING FIXTURE WITH EMERGENCY BATTERY DRIVER LINEAR LIGHTING FIXTURE (LETTER INDICATES TYPE)A FLOOR BOX WITH POWER & DATA = TYPE-SEE 2605001 2 COMMUNICATIONS OUTLET (# = # OF CABLE DROPS)-16"AFF U.O.N. CEILING-MOUNTED PHOTO SENSORPS CEILING-MOUNTED OCCUPANCY SENSOROC EMERGENCY EQUIPMENT / OUTLET CONTROL GROUP WIRING UNSWITCHED EMERGENCY BRANCH CIRCUIT WIRING M MOTOR DISCONNECT SWITCH -SNAP TYPE (SEE SPECS.)S FLOOR BOX WITH DUPLEX RECEPTACLE = TYPE-SEE 2605001 FLOOR BOX WITH DOUBLE DUPLEX RECEPTACLE = TYPE-SEE 2605001 EXISTING DEVICE TO REMAINE REPLACE EXISTING DEVICE WITH NEWR REMOVE EXISTING DEVICE AND PATCHP REMOVE EXISTING DEVICEX RELOCATED POSITION OF EXISTING DEVICEL FIRE ALARM BELL -80"AFF U.O.N.F FIRE ALARM HORN -80"AFF U.O.N.F FIRE ALARM STROBE LIGHT -80"AFF U.O.N.F FIRE ALARM HORN AND STROBE LIGHT -80"AFF U.O.N.F F FIRE ALARM MANUAL PULL STATION-48"AFF U.O.N. SMOKE DETECTOR (PHOTOELECTRIC U.O.N.) 135F HEAT DETECTOR UNLESS OTHERWISE NOTED DUCT MOUNTED SMOKE DETECTOR (S=SUPPLY; R=RETURN) CARBON MONOXIDE DETECTOR -60"AFF U.O.N.CO FSR FAN SHUTDOWN RELAY FIRE ALARM INTERFACE -ADDRESSABLE RELAY MODULEFAI FS FLOW SWITCH TS TAMPER SWITCH NEW EQUIPMENT / WIRING EXISTING EQUIPMENT / WIRING EXISTING EQUIPMENT / WIRING TO BE REMOVED FIRE ALARM SYMBOL LIST FIRE SMOKE DAMPER -ADDRESSABLE MONITOR MODULEFSD FAN CONTROL RELAY -ADDRESSABLE RELAY MODULEFCR FSI MAGNETIC DOOR HOLDER FIRE/SECURITY INTERFACE -ADDRESSABLE RELAY MODULE RECESSED CLG-MTD FIRE ALARM HORN/STROBEFS xxxx GENERAL NOTES 1.REFER TO SPECIFICATIONS FOR GENERAL REQUIREMENTS OF ALL ELECTRICAL EQUIPMENT, RACEWAYS, AND GROUNDING SYSTEMS. 2.REFER TO ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATION DETAILS FOR EXACT LOCATIONS, MOUNTING, AND ORIENTATION OF ALL LIGHTING FIXTURES, EQUIPMENT, DEVICES, AND OUTLETS. 3.REFER TO ARCHITECTURAL DRAWINGS AND ELEVATION DETAILS FOR EXACT LOCATION AND MOUNTING OF ALL RECEPTACLES, SWITCHES, TELEPHONE AND DATA OUTLETS. CONFIRM WITH ARCHITECT EXACT LOCATION AND MOUNTING HEIGHTS OF ALL DEVICES PRIOR TO INSTALLATION OF ANY WORK. 4.ALL CONDUITS SHALL BE RUN CONCEALED IN WALLS AND ABOVE HUNG CEILINGS. STUB-OUT OF WALLS AND FLOORS AS REQUIRED FOR CONNECTIONS TO EQUIPMENT AND/OR DEVICES. 5.ALL FEEDERS AND BRANCH CIRCUITS SHALL INCLUDE A SEPARATE, INSULATED GREEN GROUND CONDUCTOR, SIZED AS INDICATED AND PER NEC REQUIREMENTS. 6.COORDINATE WITH MECHANICAL, PLUMBING, FIRE PROTECTION, ARCHITECTURAL, IRRIGATION, AND LANDSCAPE DRAWINGS FOR EXACT LOCATIONS, MOUNTING HEIGHTS, AND MOUNTING DETAILS FOR ALL EQUIPMENT INSTALLED ON THIS PROJECT. WORK UNDER THIS DIVISION (26) SHALL INCLUDE ALL ELECTRICAL WORK DETAILED, SPECIFIED, OR OTHERWISE REQUIRED FOR THE SUPPORT OF OTHER TRADES, UNLESS OTHERWISE SPECIFICALLY INDICATED. 7.COORDINATE WITH MECHANICAL CONTRACTOR AND THE REQUIREMENTS OF DIVISION 23 FOR LOCATIONS OF ALL TEMPERATURE CONTROL PANELS, DUCT-MOUNTED SMOKE DETECTORS, MOTOR STARTERS, AND OTHER EQUIPMENT. POWER FOR THE SAME SHALL BE PROVIDED AND INSTALLED BY DIVISION 26. 8.PROVIDE POWER TO ALL FIRE/SMOKE DAMPERS (FSD'S) AND SMOKE DAMPERS. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS. POWER SHALL BE FROM SOURCES AS SCHEDULED ON THE ELECTRICAL DRAWINGS. 9.PROVIDE POWER TO ALL VAV BOXES AND TERMINAL CONTROL UNITS. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS. POWER SHALL BE FROM SOURCES AS SCHEDULED ON THE ELECTRICAL DRAWINGS. 10.ELECTRICAL CONTRACTOR SHALL PROVIDE POWER WIRING TO, BETWEEN, AND FROM ALL DISCONNECT SWITCHES AND MOTOR STARTERS, WHETHER IN THE SAME ENCLOSURE OR MOUNTED AS SEPARATE UNITS. ALL VARIABLE FREQUENCY DRIVES (VFD'S), COMBINATION STARTERS, AND MANUAL MOTOR STARTERS SHALL BE FURNISHED BY DIVISION 23 AND SHALL BE INSTALLED BY DIVISION 26. REFER TO SECTION 230513. 11.ALL SAFETY DISCONNECT SWITCHES SHALL BE SUPPLIED AND INSTALLED BY DIVISION 26. REFER TO SECTION 260500. REFER TO MECHANICAL AND ELECTRICAL PLANS FOR UNIT AND DEVICE LOCATIONS. SAFETY DISCONNECTS ON THE LOAD SIDE OF VFD'S SHALL BE EQUIPPED WITH AUXILIARY CONTACTS AND WIRING BACK TO RUN-ALLOW TERMINALS ON THE VFD TO PREVENT DISCONNECT FROM BEING CLOSED WITH THE VFD UNIT ACTIVATED. 12.WIRING BETWEEN MOTOR CONTROLLERS AND 2-SPEED MOTORS AND WYE/DELTA TYPE MOTORS SHALL INCLUDE 6 WIRES. WIRE SIZES SHALL MATCH FEEDER TO CONTROLLER UNLESS OTHERWISE NOTED. 13.ELECTRICAL CONTRACTOR SHALL PROVIDE 120 VOLT POWER WIRING TO ALL TEMPERATURE CONTROL PANELS, IRRIGATION CONTROL PANELS, AND OTHER CONTROLLERS SUPPLIED BY OTHER DIVISIONS. 14.DO NOT SCALE THE DRAWINGS FOR DIMENSIONS NOT INDICATED. CONSULT WITH ARCHITECT FOR RESOLUTION OF ANY DIMENSIONS NOT INDICATED. 15.PROVIDE A 1.25" EMPTY EMT CONDUIT FROM EACH TELE/DATA OUTLET BACK TO THE CLOSEST TELE/DATA CLOSET. J-HOOKS MAY BE USED FOR SUPPORT AND WIRE MANAGEMENT IN LIEU OF CONDUIT IN AREAS WITH ACCESSIBLE CEILINGS. CEILING MOUNTED CORD REELCR THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL POWER REQUIREMENTS FOR THE ABOVE SYSTEM AS OUTLINED IN DIVISION 26 & 27 SPECIFICATION SECTIONS AND/OR AS SHOWN ON THE ELECTRICAL DRAWINGS. THE ELECTRICAL CONTRACTOR SHALL PROVIDE A COMPLETE EMPTY RACEWAY AND BACKBOX SYSTEM FOR THE ABOVE SYSTEM IN ACCORDANCE WITH TELECOMMUNICATION "T" SERIES DRAWINGS, DIVISION 26 & 27 SPECIFICATION SECTIONS AND THE "E" DRAWINGS, WHERE THE MORE STRINGENT REQUIREMENT APPLIES. TELECOM SYSTEM NOTES THE TELECOM CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TELECOMMUNICATIONS EQUIPMENT, DEVICES, WIRING, AND CONNECTIONS AS SPECIFIED IN THE TELECOMMUNICATIONS SPECIFICATIONS SECTION AND RELATED DRAWINGS. 3. 2. 1. EM PUSH BUTTONHC PUSH BUTTONHC 0-10V DIMMING LIGHTING CONTROL POWER PACKPA Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 4, 2020 12" = 1'-0" Cover Sheet E-001 THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL POWER CONNECTIONS FOR THE ABOVE SYSTEM AS OUTLINED AS SHOWN ON THE ELECTRICAL DRAWINGS. THE ELECTRICAL CONTRACTOR SHALL PROVIDE A COMPLETE EMPTY RACEWAY AND BACKBOX SYSTEM FOR THE ABOVE SYSTEM IN ACCORDANCE WITH SPECIFICATIONS SECTIONS 260500. SECURITY SYSTEM NOTES THE SECURITY CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SECURITY EQUIPMENT, DEVICES, WIRING, AND CONNECTIONS AS SPECIFIED. 3. 2. 1. LIGHTING FIXTURES SCHEDULES Lighting Type DESCRIPTION MFR/MODEL WATT A SUSPENDED LINEAR I-BEAM LIGHT SVI 4 55 G1 40 (0-10V DIMMABLE)50 B LINEAR STRIP LED LIGHT ZIPTWO 707-Z2 SL-C-0-SO-35 28 C SUSPENDED LINEAR I-BEAM LIGHT SVI 4 55 G1 40 (0-10V DIMMABLE)50 D UNDERCABINET LIGHTING COMES PART OF THE FURNITURE E RECESSED 1X4 LIGHT METALUX 14SR LED SERIES 3,000K RECESSED LED 1’x4’ TROFFER WITH CURVED REFLECTOR 24.5 EXIT LED RECESSED WALL/CLG EDGE-LIT EXIT SIGN WITH LED LIGHT SOURCE, 6” RED SIGNS LETTERS ON WHITE PLEXIGLASS BACKGROUND WITH WHITE TRIM PLATE, *. CEILING / WALL / PENDANT / END RECESSED MOUNTED. DIRECTIONAL ARROWS AND MOUNTING AS REQUIRED BY PLANS. FINISH PER ARCHITECT. COOPER LIGHTING "SURE-LITES" MODEL:"ES6-FACE-WH-RW-CHEVRON-120-MOUNTING". OR EQUAL BY: EMERGI-LITE "PRESTIGE" SERIES, OR ATLITE "MARATHON" SERIES, OR McPHILBEN 45V LINE SERIES. * EXIT SIGNS INSIDE OF LECTURE HALLS SHALL SAME AS ABOVE, EXCEPT SHALL INCLUDE TRIM FINISH BRUSHED ALUMINUM, RED LETTERS, & CLEAR BACKGROUND. COORDINATE WITH ARCHITECT. COOPER LIGHTING "SURE-LITES" MODEL:"ES6-1-R-120-C/W". 5 1 WATTSTOPPER 0-10V DIMMING ROOM CONTROL LMRC-212 KEYPAD LMDM-101-W CAT 6 CAT 6 WATTSTOPPER OCCUPANCY/VAC SENSOR CAT 6 WATTSTOPPER DAYLIGHT SENSORWATTSTOPPER OCCUPANCY/VAC SENSOR CAT 6 WATTSTOPPER 0-10V DIMMING ROOM CONTROL LMRC-212 CAT 6 WATTSTOPPER OCCUPANCY/VAC SENSOR - 2 - STUDENT SPACE 186 LIGHTING CONTROL - 1 - COMMON AREA LIGHTING CONTROL WIRED NETWORK BRIDGE LMBC-300 FROM BMS BMS TO SIGNAL WHEN THE LIGHT TO TURN ON/OFF WIRED NETWORK BRIDGE LMBC-300 FROM BMS MSTP Cable FROM WATTSTOPPER WATTSTOPPER 0-10V DIMMING ROOM CONTROL LMRC-212 KEYPAD LMDM-101-W CAT 6 CAT 6 WATTSTOPPER OCCUPANCY/VAC SENSOR CAT 6 WATTSTOPPER DAYLIGHT SENSOR WATTSTOPPER OCCUPANCY/VAC SENSOR CAT 6 - 3 - STUDENT WORKSTATIONS 296 LIGHTING CONTROL WIRED NETWORK BRIDGE LMBC-300 FROM BMS STUDENT SPACE AND STUDENT WORK STATION ELECTRICAL ROOM OCCUPANCY TYPE DAYLIGHTINGCOMMON AREA SCHEDULE BUSINESS HOURS NON-BUS. HOURS ON MANUAL ONVACANCY OFF MANUAL ONMANUAL OFF MANUAL ONVACANCY OFFN/A N/A LIGHTING CONTROL SEQUENCE OF OPERATIONS MANUAL ONMANUAL OFF (BUSINESS HOURS) LABS MANUAL ONMANUAL OFFN/A MANUAL ONMANUAL OFF ONPER BUILDING SCHEDULE HOURS CORRIDOR/PUBLIC CIRCULATION OCCUPANCY ON VACANCY OFF X X XX X X X X X XLTG.CONTROLSYSTEMEND-USERINTERFACE(KEYPAD)TIMESCHEDULEWITHPHOTOCELLOVERRIDEAVINTERFACELOCALOCCUPANCYSENSOR(WITHOUTSWITCH)LOCALVACANCYSENSORWITHWALLMANUALCONTROLOCCUPANCY/VACANCYSENSORPARTOFLTG.CONTROLSYSTEMTHEATRICALCONSOLEINTERFACENOTE: 1.REFER TO FLOOR PLANS FOR EXACT LIGHTING DEVICES QUALITIES. OCCUPANCY ON VACANCY OFF PER BUILDING SCHEDULE HOURS - 4 - LIGHTING CONTROL SEQ. OF OPS. CAT 6 CAT 6 CAT 6 LMCT-100-2 PROVIDE 1. MSTP Cable FROM WATTSTOPPER MSTP Cable FROM WATTSTOPPER PA PA PA WATTSTOPPER 0-10V DIMMING ROOM CONTROL LMRC-212 WATTSTOPPER 0-10V DIMMING ROOM CONTROL LMRC-212 PA PA 1 1 Revisions: 347 West 36 Street Suite 1501 New York, NY 10018 212-245-5195 T 212-239-7130 F Key Plan: Notes: Grumman Hall Cornell University Ithaca, NY 14850 Richard McElhiney Architects LLC April 2, 2020 Issue for Bid April 2, 2020 Scale: 31 Knight Street Norwalk, CT 06851 203-866-5538 T 203-866-5243 F Altieri Sebor Wieber LLC 303 South Broadway, Suite G20 Tarrytown, NY 10591 914-333-1110 T 914-333-1109 F Jacobs Consultancy 4588 South Park Avenue Blasdell, NY 14219 716-823-0006 T Trophy Point AREA OF WORK 4592 Jordan Road Skaneateles Falls, NY 13153 315-685-4732 T Ryan Biggs Clark Davis Engineering & Surveying First and Second Floor Renovation Phase 1 Addendum 1 May 4, 2020 12" = 1'-0" Lighting Control E-003 1