Loading...
HomeMy WebLinkAboutBinder1191920202021212121202020201919 191920202021212121202020201919 191920202021212121202020201919 191920202021212121202020201919 1919202020212121212020202019191919 212020202021 2121212121212121212121212121 CB CB CB CB CB CB CB CBCB CBCB CB CBSTANDS SCOREBOARD ATHLETIC FIELD FP POSTS PARKING POSTS PARKING PARKING PLATFORM PARKING PARKING AREA PAVED PAVED PAVED PAVED UNPAVED UNPAVED PARKING TENNIS COURT TENNIS COURT TENNIS COURTS SS S RHODES HALL 2051 HOY ROAD CAMPUS ROAD COLLEGE AVENUEOAK AVENUE DRYDEN ROADAREA OF WORK AREA OF WORK CORNE LL U N I V E R SI TYFOUN D E D 5681 AD CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 Cornell University 136 HOY ROAD RHODES HALL UPS REPLACEMENT T-001 11874770 TITLE SHEET FE DESIGN EWK 2051 APRIL 8, 2020 RHODES HALL UPS REPLACEMENT SITE LOCATION -RHODES HALL KEY PLAN -PENTHOUSE LEVEL BUILDING CODE SUMMARY APPLICABLE CODES 2015 EXISTING IBC ADOPTED BY NEW YORK STATE PROJECT SUMMARY THIS PROJECT INCLUDES THE REPLACEMENT OF TWO UPS SYSTEMS. THE WORK IS ALTERATION LEVEL 2. BUILDING LIMITATIONS CONSTRUCTION CLASSIFICATION:1A CLASSIFICATION OF HAZARDS:NONE HIGH-RISE BUILDING:NO EXTINGUISHING REQUIREMENT:THE EXISTING BUILDING IS SPRINKLERED OCCUPANCY OCCUPANCY CLASSIFICATION:BUSINESS (B) DRAWING INDEX PROJECT SCOPE THIS PROJECT INCLUDES THE REPLACEMENT OF THE EXISTING 300KVA UPS SYSTEM WITH A NEW 275KVA UPS SYSTEM, REPLACING AN AUTOMATIC TRANSFER SWITCH AND ADDING PANELBOARDS FOR DISTRIBTUTION AND FOR TOTAL BYPASS OF UPS, BATTERIES AND SBM. ALSO INCLUDED IN THE SCOPE IS THE REMOVAL OF EXISTING CONCRETE PADS. GENERAL SYMBOLS LEGEND EXTERIOR ELEVATION 1 1 1 1X-100 X-100 1 1 1 1 INTERIOR ELEVATION 1 X-100 SECTION MARKER 1 X-100 ENLARGED DETAIL CONSTRUCTION KEYED NOTE DEMOLITION KEYED NOTE DRAWING REVISION NOTE# LINETYPE: TO BE PROVIDED / NEW LINETYPE: DEMOLITION / TO BE RELOCATED LINETYPE: EXISTING TO REMAIN # # T-001 TITLE SHEET S-001 GENERAL NOTES, ABBREVIATIONS, AND LEGEND S-101 PENTHOUSE FLOOR PLAN S-401 DETAILS F-001 SYMBOL LIST, GENERAL NOTES AND ABBREVIATION LIST F-101 PARTIAL PENTHOUSE FIRE PROTECTION REMOVAL PLAN F-102 BASEMENT FIRE PROTECTION PLAN F-103 PARTIAL PENTHOUSE FIRE PROTECTION PLAN F-501 FIRE PROTECTION DETAILS F-601 FIRE PROTECTION RISER DIAGRAM E-001 GENERAL NOTES AND SYMBOL LEGENDS E-101 EXISTING AND PHASE 1 PLANS E-102 PHASE 2 PLAN E-103 PHASE 3 PLAN AND PERSPECTIVE E-104 PENTHOUSE PATH OF TRAVEL E-301 PHASE 1 ONE-LINE DIAGRAM E-302 PHASE 2 ONE-LINE DIAGRAM E-303 PHASE 3 ONE-LINE DIAGRAM E-304 FINAL ONE-LINE DIAGRAM E-305 CONTROL RISER DIAGRAM 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION MATERIAL N.S. GROUT STEEL PIECES AND ERECTION PLANS POST-INSTALLED ANCHORS REQUIRED SUBMITTALS SCHEDULE / SHOP DWGS PRODUCT DATA INSPECTIONS & TESTS X X X X X WIDE FLANGE MEMBERS A992, Fy = 50 KSI STRUCTURAL STEEL GRADES HSS RECTANGULAR MEMBERS CHANNELS AND ANGLES A500 GRADE B, Fy = 46 KSI A36, Fy = 36 KSI HSS ROUND MEMBERS A500 GRADE B, Fy = 42 KSI PLATES A572, Fy = 50 KSI PIPES A53, Fy = 35 KSI THREADED RODS F1554 GRADE 36, Fy = 36 KSI W_X__ STEEL BEAM OF SIZE W_X__ STEEL BEAM WITH BEARING PLATE TYPE # BP# COLUMN UP/DOWN NEW STEEL COLUMN W_X__ EXIST. STEEL BEAM OF SIZE W_X__ EXIST. STEEL COLUMN 150 PSF INCLUDING EQUIPMENT 75 PSF PLUS LOADS FROM SPECIFIC EQUIPMENT LAYOUT 200 PSF INCLUDING EQUIPMENT GROUND SNOW LOAD, Pg 40 PSF FLAT-ROOF SNOW LOAD, Pf 31 PSF SNOW LOAD IMPORTANCE FACTOR, Is 1.10 THERMAL FACTOR, Ct 1.0 DRIFT SURCHARGE LOAD, Pd N/A SNOW DRIFT WIDTH, w N/A BASIC DESIGN WIND SPEED, V 119 MPH WIND EXPOSURE CATEGORY B RISK CATEGORY III INTERNAL PRESSURE COEFFICIENT, GCpi +/-0.18 MWRFS DESIGN PRESSURE COEFFICIENT, qz N/A C&C DESIGN PRESSURE COEFFICIENT, qcc N/A SEISMIC IMPORTANCE FACTOR, Ie 1.25 Ss 0.15g S1 0.05g ASSUMED SOIL SITE CLASS D SDS 0.160g SD1 0.08g SEISMIC DESIGN CATEGORY B SEISMIC FORCE-RESISTING SYSTEM(S)N/A BASE SHEAR, V N/A SEISMIC RESPONSE COEFFICIENT, CS N/A RESPONSE MODIFICATION COEFFICIENT, R N/A RAIN INTENSITY, i DESIGN PARAMETERS 2.35 INCHES/HOUR ALLOWABLE STRESS DESIGN WIND SPEED 92 MPH SOIL DESIGN PRESSURE N/A ANALYSIS PROCEDURE N/A EXPOSURE FACTOR, Ce 1.0 SLOPE FACTOR, Cs N/ASNOW WINDSEISMICCORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT S-001 11874770 GENERAL NOTES, ABBREVIATIONS, AND LEGEND Q. OLSEN QO 2051 APRIL 8, 2020 CODES 1. PERFORM ALL CONSTRUCTION IN ACCORDANCE WITH THE 2020 NEW YORK STATE BUILDING CODE AND CITY OF ITHACA AMENDMENTS REFERENCING THE FOLLOWING CODES AND STANDARDS: A. ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE B. ASCE7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES WITH SUPPLEMENT NO. 1 C. 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) D. 2018 INTERNATIONAL BUILDING CODE (IBC) DEFLECTION CRITERIA 1. GRAVITY LOAD DEFLECTION CRITERIA: A. TOTAL LOAD: L/240 B. LIVE LOAD: L/360 DESIGN LOADS 1.DEAD LOADS PER THE EXISTING DRAWINGS A. EXISTING CONCRETE ON METAL DECK: 77 PSF B. CEILING: 5 PSF C. MEP: 5 PSF D. 3”NORMAL WEIGHT CONCRETE TOPPING 38 PSF 2.ADDITIONAL DEAD LOADS: A. EXISTING STRUCTURAL STEEL FRAMING: 7 PSF 3.LIVE LOADS: A. THE ELECTRICAL ROOM HAS A LIVE LOAD RATING OF 150 PSF PER THE EXISTING DRAWINGS. SEE LIVE LOAD MAP FOR CHANGES. B. BATTERY CABINET: 4678 LBS (PER CABINET) C. UPS: 2150 LBS (PER UPS) D. SBM: 700 LBS STRUCTURAL STEEL 1. ALL STRUCTURAL STEEL SHALL BE ASTM FABRICATED AND ERECTED IN ACCORDANCE WITH AISC "STEEL CONSTRUCTION MANUAL" AND ALL WORK SHALL COMPLY WITH AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES." 2. GRADES OF STRUCTURAL STEEL TO BE PER TABLE THIS SHEET U.O.N. 3. ALL BOLTED CONNECTIONS TO BE MADE WITH A325 OR A490 TYPE N HIGH STRENGTH BOLTS UNLESS GALVANIZED BOLTS ARE SPECIFIED. WHERE GALVANIZED BOLTS ARE SPECIFIED ON THE DRAWINGS, GALVANIZED BOLTS SHALL CONFORM TO ASTM A153, CLASS C AND SHALL BE HOT-DIP GALVANIZED . 4. ALL NUTS SHALL MEET REQUIREMENTS OF ASTM A-563 DH OR ASTM A-194 2H. 5. ALL WASHERS SHALL MEET REQUIREMENTS OF ASTM F-436. 6. ALL BOLT HOLES IN STEEL MEMBERS SHALL BE 1/16" LARGER IN DIAMETER THAN THE NOMINAL SIZE OF THE BOLT USED, U.N.O. ON DRAWINGS. 7. WELDING SHALL MEET THE REQUIREMENTS OF OF THE "STRUCTURAL WELDING CODE" AWS D1.1-2006. ELECTRODES SHALL HAVE A MINIMUM TENSILE STRENGTH OF 70 KSI AND BE LOW-HYDROGEN TYPE. THE LENGTH OF WELD SPECIFIED ON THE DRAWINGS IS THE MINIMUM EFFECTIVE LENGTH OF THE WELD. ALL WELDS TO BE A MINIMUM 1/4" FILLET WELD U.N.O. ON DRAWINGS. 8. ALL INTERIOR STEEL SHALL BE PAINTED IN THE SHOP WITH DEVGUARD 4360 OR APPROVED EQUAL U.N.O. ON THE DRAWINGS. 9. ALL STEEL SHALL BE INSTALLED WITH CAMBER UP EXCEPT WHERE NOTED OTHERWISE ON DRAWINGS AND AT CANTILEVERS WHERE STEEL SHALL BE INSTALLED WITH CAMBER DOWN. 10. NO FABRICATION SHALL PROCEED PRIOR TO SHOP DRAWING APPROVAL. SHOP DRAWINGS MARKED "REJECTED" OR "REVISE AND RESUBMIT" MAY NOT BE FABRICATED WITHOUT ADDITIONAL CHANGES BEING MADE. 11. DEVELOPMENT OF STRUCTURAL STEEL SHOP DRAWINGS SHALL BE SUPERVISED BY A NEW YORK STATE-REGISTERED PROFESSIONAL ENGINEER AND SHALL INCLUDE DETAILS FOR APPLICATIONS AND ASSEMBLY OF ALL STRUCTURAL MEMBERS; INCLUDE DETAILS OF CUTS, CONNECTIONS, HOLES, AND OTHER PERTINENENT DATA; AND INDICATE WELDS BY STANDARD AWS 2.1 SYMBOLS SHOWING SIZE, LENGTH, AND TYPE OF EACH WELD. SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATION. 12. SPLICING OF STRUCTURAL MEMBERS WHERE NOT DETAILED ON THE CONTRACT DOCUMENTS IS PROHIBITED WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER AS TO LOCATION, TYPE OF SPLICE, AND CONNECTION TO BE MADE. POST-INSTALLED ANCHORS 1. UNLESS NOTED OTHERWISE ON DRAWINGS, THE FOLLOWING EPOXIES ARE TO BE USED WITH THE FOLLOWING BASE MATERIALS FOR ADHESIVE ANCHORS: A. CAST IN PLACE AND PRECAST CONCRETE –HILTI HIT HY 200 R, POWERS AC200+, OR POWERS AC100+ GOLD B. CONCRETE MASONRY UNITS –HILTI HIT HY 270 OR POWERS AC100+ GOLD 2. EXPANSION ANCHORS TO BE STAINLESS STEEL. MANUFACTURER OF EXPANSION ANCHORS TO BE HILTI OR POWERS (DEWALT) OR APPROVED EQUAL. SUBMIT EXPANSION ANCHOR PRODUCT DATA FOR APPROVAL BY STRUCTURAL ENGINEER OF RECORD PRIOR TO INSTALLATION. TESTING & INSPECTIONS 1. OWNER SHALL RETAIN THE SERVICES OF AN INSPECTION AGENCY TO PERFORM THE FOLLOWING SERVICES. ADDITIONAL INSPECTIONS SHALL BE PROVIDED IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. 2. ALL NEW BOLTED CONNECTIONS SHALL BE VISUAL INSPECTED FOR CONFORMANCE WITH INDUSTRY STANDARDS FOR INSTALLTION AND FOR CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS. 3. ALL NEW STRUCTURAL WELDS MUST BE VISUALLY INSPECTED FOR CONFORMATIONS WITH INDUSTRY STANDARDS FOR INSTALLATION AND FOR CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS. IF THE WELDERS DO NOT HAVE AWS CERTIFICATION, ALL OF THE STRUCTURAL WELDS MUST BE TESTED WITH 100% MAGNETIC PARTICLE TESTING TO CONFIRM THE WELDS MEET THE MINIMUM STRENGTH REQUIREMENTS FOR THE CONNECTIONS. STRUCTURAL GENERAL NOTESLIVE LOAD MAP STRUCTURAL LEGEND 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION 1 2 3 E D C 1 2 3 E D C7' - 6 5/8"7' - 6 5/8"7' - 6 5/8"1 5' - 2 1/4" 5' - 10 3/4" 6' - 7 1/4" 7' - 3 3/4" (E) W12X16 BELOW (E) W12X16 BELOW BEAMS EXTEND 3" PAST GRIDLINE BEAMS EXTEND 3" PAST GRIDLINE 1/2" GAP BETWEEN ENDS OF BEAMS, TYP. ABOVE EXISTING BEAMS (E) W36X150 BELOW (E) W36X150 BELOW (E) W21X50 BELOW(E) W24X55 BELOWCORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT S-101 11874770 PENTHOUSE FLOOR PLAN Q. OLSEN JD 2051 APRIL 8, 2020 SCALE:1/4" = 1'-0"1 NEW FRAMING ABOVE SLAB 0 2 4 8 SCALE: 1/4"=1'-0" GENERAL NOTES 1. EXISTING BATTERY CABINETS CAN REMAIN IN PLACE WHEN STEEL IS INSTALLED. 2. REMOVE TWO EXISTING BATTERY CABINETS PRIOR TO INSTALLATION OF TWO NEW CABINETS. REMOVE REMAINING TWO EXISTING BATTERY CABINETS PRIOR TO INSTALLATION OF FINAL TWO NEW CABINETS. THIS IS CRITICAL FOR THE LOAD OF THE CABINETS TO NOT EXCEED THE CAPACITY OF THE STRUCTURAL FRAMING. WHEN BATTERIES ARE BROUGHT INTO THE ROOM, THEY MUST BE BROUGHT IN WITH ONLY A SINGLE LAYER OF BATTERIES ON THE PALLET. IF THE CONTRACTOR WISHES TO TRANSPORT THE BATTERIES IN A DIFFERENT WAY, THE ENGINEER OF RECORD MUST APPROVE FIRST. 3. SEE ELECTRICAL DRAWINGS FOR THE EXACT LAYOUT OF THE BATTERY CABINETS. THE CABINETS MUST BE CENTERED BETWEEN GRIDS D AND E. THE CABINETS MUST BE CENTERED ON THE NEW STEEL BEAMS IN THE EAST-WEST DIRECTION. 4. SEE ELECTRICAL DRAWINGS FOR CONCRETE EQUIPMENT PADS TO BE REMOVED IN THE 1-2/D-E BAY MUST BE REMOVED PRIOR TO THE INSTALLATION OF THE BATTERY CABINETS. THE CONCRETE PADS IN THE 1-2/C-D BAY MUST BE REMOVED PRIOR THE UPS & SBM INSTALLATIONS. CONTRACTOR TO PROTECT EXISTING STRUCTURAL SLAB DURING DEMO OF CONCRETE EQUIPMENT PADS. 5. CONTRACTOR TO REVIEW SEQUENCE OF DEMO AND INSTALLATION WITH STRUCTURAL ENGINEER PRIOR TO BEGINNING DEMO AND INSTALLATION. THERE ARE LIMITED OPTIONS FOR TEMPORARY SHORING BECAUSE OF THE SERVER ROOM LOCATED DIRECTLY BELOW. SEE THE LIVE LOAD MAP ON S-001 FOR THE MAXIMUM LOADS THAT CAN BE PLACED ON THE FLOOR IN EACH AREA WITHOUT ANY SHORING BEING REQUIRED. THESE LOADS ASSUME THE CONCRETE EQUIPMENT PADS HAVE ALREADY BEEN REMOVED. S-100 KEYED CONSTRUCTION NOTES 1 12 NEW W8 X 31 BEAMS TO BE INSTALLED SO THAT THE BOTTOM OF THE STEEL IS 1 ½” ABOVE THE TOP OF THE SLAB. # 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION NEW BATTERY CABINET MAXIMUM 1/2" GAP BETWEEN ENDS OF BEAMS FLOOR 1/2" Ø EXPANSION ANCHORS EMBEDDED A MINIMUM OF 2" INTO EXISTING CONCRETE 1' - 1" 3"3" 3'-2" X 1'-1" X 1/2" STEEL PLATE WITH FOUR (4) EXPANSION ANCHORS 1/2" Ø EXPANSION ANCHORS EMBEDDED A MINIMUM OF 2" INTO EXISTING CONCRETE ANCHORS TO ONLY BE LOCATED AT BEARING PLATES (12 ANCHORS IN TOTAL) 3 3/4"3" 3'-2" X 6-3/4" X 1/2" STEEL PLATE WITH TWO (2) EXPANSION ANCHORS 3/4" 3/16" NEW BATTERY CABINET 1/2" Ø EXPANSION ANCHORS EMBEDDED A MINIMUM OF 2" INTO EXISTING CONCRETE 1/2" Ø EXPANSION ANCHORS EMBEDDED A MINIMUM OF 2" INTO EXISTING CONCRETE HOLES IN PLATE FOR ANCHORS TO BE 3/4" Ø 3' - 2" 1"1" 1/2" THICK X 3'-2" LONG STEEL PLATE. WIDTH VARIES, SEE OTHER DETAILS THIS SHEET PROVIDE 3/4"X1" SLOT IN BOTTOM FLANGE OF BEAM WHERE IT BEARS ON PLATE. WELD BEAM TO PLATE. 3/16"3/16" WELD BEAM TO PLATEWELD BEAM TO PLATE CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT S-401 11874770 DETAILS Q. OLSEN JD 2051 APRIL 8, 2020 SCALE:1 1/2" = 1'-0"3 TYPICAL BEARING CONNECTION MIDDLE SCALE:1 1/2" = 1'-0"1 TYPICAL BEARING CONNECTION AT END SCALE:1 1/2" = 1'-0"2 TYPICAL BEARING CONNECTION SECTION SCALE: 1-1/2"=1'-0" 6 1 20 3 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION ARCHIVE BAR CODEITHACA, NEW YORK Rhodes Hall UPS Replacement ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: P11874770 DATE: FACILITY: DESIGN: DRAWN: TMT TMT 2051 April 8, 2020 WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONSCORNELLUNIV E RSI TYFOUN DE D 5681AD FACILITIES ENGINEERING ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 GHD Project #11205715 GHD Consulting Services Inc. 5788 Widewaters Pkwy Syracuse NY 13214 USA T 1 315 802 0260 F 1 315 802 0450 RHODES HALL ISSUE FOR 95% REVIEW103/20/20 100% FOR CONSTRUCTION204/08/20 F-001 SYMBOL LIST, GENERAL NOTES AND ABBREVIATION LIST FIRE PROTECTION SYMBOL LIST MANUAL PULL STATION. MOUNTING HEIGHT: +48" AFF (TO CENTER) SMOKE SENSOR, PHOTOELECTRIC, CEILING MOUNTED FIRE ALARM CONTROL PANEL FIRE ALARM GENERAL NOTES: 1.THE SYSTEM SHALL INCLUDE ALL WIRING, RACEWAYS, PULL BOXES, TERMINAL CABINETS, OUTLET AND MOUNTING BOXES, CONTROL EQUIPMENT, ALARM, AND SUPERVISORY SIGNAL INITIATING DEVICES, ALARM NOTIFICATION APPLIANCES, INTERFACE EQUIPMENT, AND OTHER ACCESSORIES AND MISCELLANEOUS ITEMS INCLUDING SOFTWARE, SYSTEM PROGRAMMING, TESTING AND CONSTRUCTION PERMITS REQUIRED FOR A COMPLETE OPERATING SYSTEM EVEN THOUGH EACH ITEM IS NOT SPECIFICALLY MENTIONED OR DESCRIBED. PROVIDE SYSTEM COMPLETE AND READY FOR OPERATION. THE SYSTEM MUST COMPLY WITH THE 2015 INTERNATIONAL BUILDING CODE (IBC) WITH THE 2017 NYS UNIFORM CODE SUPPLEMENT. 2.PROVIDE ALL WIRING FROM APPLIANCE TERMINAL TO APPLIANCE TERMINAL. PROVIDE CONDUCTORS THAT ARE TERMINATED, SPLICED, OR OTHERWISE INTERRUPTED IN ANY ENCLOSURE, CABINET, MOUNTING, OR JUNCTION BOX CONNECTED TO SCREW-TYPE TERMINAL BLOCKS. WIRE NUTS AND SIMILAR DEVICES ARE PROHIBITED. 3.PROVIDE ALL FIRE ALARM CIRCUITS SUPERVISED UNLESS NOTED OTHERWISE, AS FOLLOWS IN ACCORDANCE WITH NFPA 72 (2013): ·INITIATING DEVICE CIRCUITS (IDC)- CLASS B ·NOTIFICATION APPLIANCE CIRCUITS (NAC)- CLASS B, SYNCHRONIZED ·SIGNALING LINE CIRCUITS (SLC)- CLASS B 4.PROVIDE SMOKE DETECTORS A MINIMUM OF 3 FEET FROM EXISTING AIR DIFFUSERS. 5.PROVIDE VISUAL WARNING STROBE/AUDIBLE NOTIFICATION APPLIANCES TO ACHIEVE MAXIMUM AUDIBILITY AND VISIBILITY IN ACCORDANCE WITH NFPA 72 GUIDELINES. PROVIDE CARE IN LOCATING VISUAL WARNING STROBE APPLIANCES TO ENSURE VISIBILITY AND AVOID OBSTRUCTIONS. 6.LABEL ALL ADDRESSABLE INPUT/OUTPUT FIRE ALARM COVER PLATES AND APPLIANCES (INCLUDING HORNS, STROBES, SMOKE SENSORS, HEAT SENSORS, MANUAL PULL STATIONS, ADDRESSABLE MODULES, ETC.) WITH THEIR ADDRESS UTILIZING A LABELING MACHINE. HAND WRITTEN LABELS MUST NOT BE USED. ADDRESS MUST INCLUDE NAC OR SLC NUMBER FOLLOWED BY APPLIANCE NUMBER. EACH SLC FIELD APPLIANCE ADDRESS MUST MATCH THE FIRE ALARM DISPLAY ADDRESS. 7.UNLESS OTHERWISE NOTED THE PROJECT ELECTRICAL CONDUIT STANDARD IS ELECTRICAL METALLIC TUBING (EMT) AND PROVIDED THROUGHOUT THE PROJECT. PROVIDE ALL WIRING IN CONDUIT WHERE WIRES WOULD OTHERWISE BE EXPOSED. WIRING MAY BE CONCEALED WITHIN WALLS AND CEILINGS WHERE APPLICABLE. 8.FLEXIBLE METAL CONDUIT (FMC) IS LIMITED TO 5 FEET AND SECURED PER THE NATIONAL ELECTRIC CODE (2014). FMC IS PERMITTED FOR DEVICES LOCATED ON FIRE SUPPRESSION EQUIPMENT ONLY SUCH AS FLOW/PRESSURE SWITCHES, SOLENOIDS AND TAMPER SWITCHES. 9.PROVIDE CONDUIT AS UNOBTRUSIVELY AS POSSIBLE, AS CLOSE AS POSSIBLE TO FLOOR/ CEILING SLAB AND PARALLEL AND AT RIGHT ANGLES TO STRUCTURAL ELEMENTS. 10.PROVIDE ELECTRICAL BOXES AS FOLLOWS: UNLESS OTHERWISE NOTED PROVIDE CAST METAL BELL TYPE BOXES WITH THREADED HUBS ON EXPOSED WORK, EXCEPT WHERE FACTORY BOXES ARE PROVIDED. CONCEALED BOXES MAY BE STAMPED STEEL BOXES. PROVIDE TERMINAL CABINETS OF SOLID WALL CONSTRUCTION WITH NO FACTORY CONDUIT KNOCK OUTS. 11.PAINT ALL CONDUIT, FIRE ALARM JUNCTION BOXES AND COVERS RED IN UNFINISHED AREAS. 12.CORE DRILL PENETRATIONS IN MASONRY WALLS AND FLOOR/CEILING SLABS. 13.BOTH EXPOSED AND CONCEALED CONDUIT INCLUDING RISERS UP TO 2 INCHES IN DIAMETER MUST UTILIZE COMPRESSION TYPE STEEL FITTINGS AND CONNECTORS. UNLESS OTHERWISE NOTED PROVIDE ALL CONDUIT 3/4 INCH MINIMUM TRADE SIZE. PROVIDE VERTICAL RISERS ONE INCH DIAMETER MINIMUM. PROVIDE PLENUM RATED WIRING CONDUCTORS (TYPE FPLP) WHEN FLEX CONDUIT IS UTILIZED. PROVIDE SOLID COPPER WIRING CONDUCTORS INSTALLED IN CONDUIT FOR THE FOLLOWING CIRCUITS (AT MINIMUM): ·FIRE ALARM INITIATING DEVICE CIRCUITS (IDC) - 14/2 AWG ·FIRE ALARM SIGNALING LINE CIRCUITS (SLC) - 16/2 AWG TWISTED PAIR ·FIRE ALARM VISUAL NOTIFICATION APPLIANCES - 12/2 AWG. ·120 VAC - PRIMARY POWER - NO. 12 AWG, THHN/THWN 600VAC INSULATED PROVIDE ALL WIRING UL LISTED FOR ITS INTENDED USE. 14.SECURE ALL NECESSARY CONSTRUCTION PERMITS, INSPECTIONS AND FINAL SYSTEM ACCEPTANCE. 15.CONTRACT DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND USED IN CONJUNCTION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION. CONTRACTOR MUST COORDINATE ALL DRAWINGS AND SPECIFICATIONS PRIOR TO COMMENCING WORK. 16.VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE CONCERNING THE WORK BEFORE PROCEEDING WITH EITHER FABRICATION OR INSTALLATION OF WORK. LOCATION OF EQUIPMENT IS APPROXIMATE. VERIFY THE LOCATION OF ALL SYSTEM COMPONENTS. 17.AVOID ALL CONFLICTS WITH EXISTING LIGHT FIXTURES, HVAC DIFFUSERS, GRILLES, DUCTS, CONDUIT AND OTHER PIPING OR OTHER OBSTRUCTIONS ENCOUNTERED. COORDINATE ALL WORK WITH FIELD CONDITIONS. 18.DO NOT CUT OR PATCH STRUCTURAL WORK IN A MANNER THAT WOULD RESULT IN A REDUCTION OF LOAD-CARRYING OR LOAD-DEFLECTION RATIO. 19.PROVIDE ACCEPTANCE TESTING OF THE FIRE ALARM SYSTEM IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 20."PROVIDE" MEANS CONTRACTOR MUST FURNISH NEW AND INSTALL COMPLETE AND READY FOR INTENDED USE. F FACP S P F H FIRE ALARM HORN/STROBE FIRE ALARM REMOTE ANNUNCIATOR PANELANN FIRE FIGHTER PHONEP SUPERVISED CONTROL VALVE CHECK VALVE PREACTION VALVE UPRIGHT SPRINKLER SPRINKLER PIPE AIR COMPRESSORAC FIRE ALARM 2-HOUR CI CABLE IN CONDUIT EXISTING UPRIGHT SPRINKLER EXISTING SPRINKLER PIPE EXISTING TO REMAINEX HYDROGEN GAS DETECTORH EXISTING ELECTRICAL POWER PANELELECEX G H GAS DETECTION HORN/STROBE, RED STROBE, HIGH/LOW TONE ADDRESSABLE RELEASING CONTROL PANELRCP SOLENOID VALVESV WATERFLOW SWITCHWF TAMPER SWITCHTS LOW AIR SUPERVISORY SWITCHLA ADDRESSABLE OUTPUT MODULE ADDRESSABLE INPUT MODULEAIM AOM ADDRESSABLE RELAYAR END OF LINE RESISTOREOL CONNECT TO EXISTING REMOVE DEVICE AND ASSOCIATED EQUIPMENT TRANSIENT VOLTAGE SURGE SUPPRESSIONTVSS FULL-PORT BALL VALVE VELOMETERV DN LOUVERS LOUVERS LOUVERS LOUVERSLOUVE R S 80003 80046 80047 80061 80064 80060 801 802 801A 804 807 809 811 80062 S P S P S P S P FH EXPEX PEX ELECELECEX EX ARCHIVE BAR CODEITHACA, NEW YORK Rhodes Hall UPS Replacement ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: P11874770 DATE: FACILITY: DESIGN: DRAWN: TMT TMT 2051 April 8, 2020 WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONSCORNELLUNIV E RSI TYFOUN DE D 5681AD FACILITIES ENGINEERING ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 GHD Project #11205715 GHD Consulting Services Inc. 5788 Widewaters Pkwy Syracuse NY 13214 USA T 1 315 802 0260 F 1 315 802 0450 RHODES HALL ISSUE FOR 95% REVIEW103/20/20 100% FOR CONSTRUCTION204/08/20 PARTIAL PENTHOUSE FIRE PROTECTION REMOVAL PLAN SCALE: 3/16" = 1'-0"0 SCALE 3/16"=1'-0" AT ORIGINAL SIZE 8'-0"6'-0"4'-0"2'-0" GENERAL NOTES: A. 1 KEYED NOTES: EXISTING BUILDING FIRE ALARM HORN/STROBE AND FIRE PHONE SHALL REMAIN. EXISTING SMOKE DETECTORS LOCATED WITHIN THE ENERGY STORAGE SYSTEM ROOM AND ASSOCIATED CONDUIT AND WIRING SHALL BE REMOVED. F-101 PARTIAL PENTHOUSE FIRE PROTECTION REMOVAL PLAN DN DN DN KEY PLAN NO SCALE AREA OF WORK 1 1 UP UP RAMP UP B0069 B10 B20 B0064 B0066 B50 B0067 B0068 B60 B0073 B0071 B0072 B0020 B0021 B0070 B0004 B0003 B0074 B0065 B40 B30 B0075 B18B31 B33 B35 B37 B0063 B0062 B0061 F A C P ANNANNEX EX EXFACP ARCHIVE BAR CODEITHACA, NEW YORK Rhodes Hall UPS Replacement ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: P11874770 DATE: FACILITY: DESIGN: DRAWN: TMT TMT 2051 April 8, 2020 WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONSCORNELLUNIV E RSI TYFOUN DE D 5681AD FACILITIES ENGINEERING ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 GHD Project #11205715 GHD Consulting Services Inc. 5788 Widewaters Pkwy Syracuse NY 13214 USA T 1 315 802 0260 F 1 315 802 0450 RHODES HALL ISSUE FOR 95% REVIEW103/20/20 100% FOR CONSTRUCTION204/08/20 BASEMENT FIRE PROTECTION PLAN SCALE: 3/32" = 1'-0" 0 SCALE 3/32"=1'-0" AT ORIGINAL SIZE 16'-0"12'-0"8'-0"4'-0" GENERAL NOTES: A. B. C. INSTALL ALL CONDUIT EXPOSED IN AREAS WITH NO FINISHED CEILINGS UNLESS OTHERWISE NOTED. INSTALL ALL WIRING AND CONDUIT WITH THE REQUIRED SUPPORT/HANGERS. INSTALL ALL SUPPORTS FROM THE BUILDING STRUCTURE. FIRE STOP ALL PENETRATIONS THROUGH RATED WALLS, FLOORS AND CEILINGS. F-102 BASEMENT FIRE PROTECTION PLAN EXISTING FIRE PUMP LOCATION FOR HYDRAULIC CALCULATION PURPOSES EXISTING 6-INCH STANDPIPE FIRE ALARM CONDUIT UP TO PENTHOUSE FIRE ALARM SUBPANEL KEYED NOTES: 2-HOUR CIRCUIT INTEGRITY FIRE ALARM CABLING SHALL BE INSTALLED WITHIN EMT CONDUIT. LOCATION OF VERTICAL CONDUIT RUNS SHALL BE COORDINATED WITH BUILDING PERSONNEL. IF A COMMON VERTICAL CONDUIT LOCATION IS FOUND, IT SHALL BE UTILIZED. PROVIDE NEW FCI E3 FACP ADJACENT TO THE EXISTING FCI 72C FACP TO RECEIVE ALARM, SUPERVISORY AND TROUBLE SIGNALS FROM THE PENTHOUSE RELEASING PANEL AND REPORTING ALARM SIGNALS THROUGH THE EXISTING MAIN FACP TO THE CAMPUS CENTRAL STATION AT BARTON HALL. PROVIDE AN ADDRESSABLE MODULE AND RECIRCUIT ONE EXISTING BASEMENT FLOOR FIRE ALARM ZONE THROUGH IT TO THE NEW FACP. CONNECT THE NEW FACP TO THE NEW SPARE ZONE IN THE EXISTING FACP. 1 2 2 1 2 3 3 DN FH EXPEX FH F H F H ACRCPFH HH H ELECELECEX EX PEX HH S P GH GH G H GH GH G H F F F WF AIM LA AIM TS AIM S P S P S P S P S P F H AIM FH FH F H ARCHIVE BAR CODEITHACA, NEW YORK Rhodes Hall UPS Replacement ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: P11874770 DATE: FACILITY: DESIGN: DRAWN: TMT TMT 2051 April 8, 2020 WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONSCORNELLUNIV E RSI TYFOUN DE D 5681AD FACILITIES ENGINEERING ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 GHD Project #11205715 GHD Consulting Services Inc. 5788 Widewaters Pkwy Syracuse NY 13214 USA T 1 315 802 0260 F 1 315 802 0450 RHODES HALL ISSUE FOR 95% REVIEW103/20/20 100% FOR CONSTRUCTION204/08/20 PARTIAL PENTHOUSE FIRE PROTECTION PLAN SCALE: 1/8" = 1'-0" GENERAL NOTES: A. B. C. D. E. F. G. H. I. J. K. L. M. N. KEYED NOTES: PROVIDE ADDRESSABLE FIRE ALARM RELEASING CONTROL PANEL. SEE RISER DIAGRAM ON DRAWING F-600. 2-HOUR CIRCUIT INTEGRITY CABLING FIRE ALARM WIRING SHALL BE INSTALLED WITHIN EMT CONDUIT. POWER PANEL ELP-P SHALL BE UTILIZED FOR POWER FOR FIRE PROTECTION DEVICES, I.E. FIRE ALARM CONTROL PANEL, AIR COMPRESSOR, MONITORING EQUIPMENT (WATERFLOW SWITCH, SUPERVISORY SWITCH, TAMPER SWITCH), SOLENOID VALVE. LOCATION OF VERTICAL CONDUIT RUNS SHALL BE COORDINATED WITH BUILDING PERSONNEL. IF A COMMON VERTICAL CONDUIT LOCATION IS FOUND, IT SHALL BE UTILIZED. HYDROGEN GAS DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND SHALL BE PROGRAMMED TO A SENSITIVITY OF 12.5% OF THE LOWER FLAMMABILITY LIMIT OF HYDROGEN GAS. MANUFACTURER REPRESENTATIVE SHALL FIELD VERIFY THAT HYDROGEN DETECTOR SPACING WILL BE EFFECTIVE. MAIN DRAIN AND INSPECTOR'S TEST DISCHARGE SHALL BE COORDINATED WITH EXISTING DRAIN RISER. CAPACITY OF EXISTING DRAIN TO BE UTILIZED SHALL BE CONFIRMED. PROVIDE ADDRESSABLE INPUT MODULE ABOVE OR ADJACENT TO CELLWATCH CONTROL UNIT. INPUT MODULE SHALL SUPERVISE CU RELAY OUTPUT #5 (WARNING). PROVIDE FLUSHING FULL-PORT BALL VALVE ON EACH BRANCH LINE MATCHING THE SIZE OF THE BRANCH LINE PIPING. PROVIDE THREE 2-1/2" FLUSHING FULL PORT BALL VALVES ON THE END OF THE 6-INCH SUPPLY MAIN. PREACTION VALVE DRAIN PIPING SHALL BE ROUTED DOWN TO THE FLOOR BELOW THEN TO THE EXISTING DRAIN RISER. PROVIDE A COMPLETE AUTOMATIC FIRE ALARM SYSTEM IN ACCORDANCE WITH THE 2020 BUILDING CODE OF NEW YORK STATE AND NFPA 72 (2016) FOR THE ENERGY STORAGE SYSTEM ROOM. PROVIDE A COMPLETE AUTOMATIC PREACTION SPRINKLER SYSTEM IN ACCORDANCE WITH THE 2020 BUILDING CODE OF NEW YORK STATE AND NFPA 13 (2016) FOR THE ENERGY STORAGE SYSTEM ROOM. PIPING AS SHOWN IS DIAGRAMMATIC, NOT ALL PIPING/FITTINGS ARE INDICATED. CONTRACTOR IS RESPONSIBLE FOR FINAL SPRINKLER SYSTEM PIPE SIZING/LAYOUT, SPRINKLER HYDRAULIC CALCULATIONS, AND COORDINATION WITH LIGHT FIXTURES/FIRE ALARM DEVICES, DUCTWORK AND DIFFUSERS. FINAL PIPE SIZING SHALL BE DETERMINED BY CONTRACTOR HYDRAULIC CALCULATIONS SUBJECT TO APPROVAL BY ENGINEER. MAXIMUM SPRINKLER COVERAGE AREA SHALL BE 120 SQ.FT. SPRINKLER DESIGN CRITERIA IS AS FOLLOWS: 0.30GPM/SQ.FT. OVER THE ENTIRETY OF THE ESS ROOM, 100 GPM HOSE STREAM DEMAND AT TOP OF STANDPIPE & 400 GPM AT WATER SUPPLY SOURCE. INSTALL ALL CONDUIT EXPOSED IN AREAS WITH NO FINISHED CEILINGS UNLESS OTHERWISE NOTED. INSTALL ALL WIRING AND CONDUIT WITH THE REQUIRED SUPPORT/HANGERS. INSTALL ALL SUPPORTS FROM THE BUILDING STRUCTURE. INSTALL ALL INITIATING DEVICES IN A MANNER THAT PROVIDES ACCESSIBILITY FOR PERIODIC INSPECTION, TESTING AND MAINTENANCE. FIRE STOP ALL PENETRATIONS THROUGH RATED WALLS, FLOORS AND CEILINGS. ALL PIPE SIZES SHALL BE SCHEDULE 40 BLACK STEEL WITH THREADED FITTINGS. SPRINKLERS SHALL BE LOCATED A MINIMUM OF 24 INCHES FROM THE SIDE OF HVAC DIFFUSERS. ALL SPRINKLER PIPING SHALL BE PITCHED BACK TO THE PREACTION VALVE TO ALLOW FOR PROPER DRAINAGE AND TO ELIMINATE THE POSSIBILITY OF TRAPPED WATER. SPRINKLER SUPPLY MAIN AND BRANCH PIPING SHALL BE ROUTED DIRECTLY BELOW THE STRUCTURAL I-BEAMS WITH VERTICAL PIPING UP TO THE DECK FOR EACH UPRIGHT SPRINKLER. F-103 PARTIAL PENTHOUSE FIRE PROTECTION PLAN 0 SCALE 3/16"=1'-0" AT ORIGINAL SIZE 8'-0"6'-0"4'-0"2'-0" DN DN DN KEY PLAN NO SCALE AREA OF WORK EXISTING 6-INCH STANDPIPE 6" 6" 6" FIRE ALARM CONDUIT DOWN TO BASEMENT 6-INCH PREACTION VALVE ASSEMBLY (SEE DETAIL 1 "PREACTION FIRE SPRINKLER VALVE" ON DRAWING F-500) EXISTING 2-INCH MAIN DRAIN DISCHARGE ENERGY STORAGE SYSTEM LOCATIONS TYP. DOWN TO INSPECTOR TEST CONNECTION. SEE DETAIL 5 "INSPECTOR TEST DETAIL" ON DRAWING F-500. DRAIN TO EXISTING STAIRWELL DRAIN RISER. TYP. 3 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 ARCHIVE BAR CODEITHACA, NEW YORK Rhodes Hall UPS Replacement ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: P11874770 DATE: FACILITY: DESIGN: DRAWN: TMT TMT 2051 April 8, 2020 WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONSCORNELLUNIV E RSI TYFOUN DE D 5681AD FACILITIES ENGINEERING ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 GHD Project #11205715 GHD Consulting Services Inc. 5788 Widewaters Pkwy Syracuse NY 13214 USA T 1 315 802 0260 F 1 315 802 0450 RHODES HALL ISSUE FOR 95% REVIEW103/20/20 100% FOR CONSTRUCTION204/08/20 F-501 FIRE PROTECTION DETAILS 6-INCH FROM FIRE PROTECTION WATER SUPPLY SUPERVISED CONTROL VALVE WITH TAMPER SWITCH WIRED TO ESS ROOM SUBPANEL LOW AIR PRESSURE SUPERVISORY SWITCH WIRED TO ESS ROOM SUBPANEL AUTO AIR MAINTENANCE DEVICE PRESSURE GAUGE (TYPICAL) FINISHED FLOOR CHECK VALVE TO PREACTION SYSTEM 6-INCH PREACTION VALVE AIR COMPRESSOR MANUAL EMERGENCY RELEASE DEVICE PRESSURE OPERATED RELIEF VALVE CONCRETE BASE WITH BASE ELBOW MAIN DRAIN DISCHARGE WITH 45° ELBOW 24" ± ABOVE EXISTING CAPABLE PLUMBING DRAIN EXTERIOR WALL DRAIN CUP STRAINER ORIFICE CHECK VALVE WATERFLOW SWITCH ELECTRIC RELEASE SOLENOID VALVE STRAINER DRDR DRNO SCALE PREACTION FIRE SPRINKLER VALVE TO ESS ROOM SUBPANEL AI AR R SLC TO NEXT DEVICE 120v SHUNT TRIP POWER SLC TO NEXT DEVICE EMT (TYPICAL) ADDRESSABLE LOAD CONTROL FIELD RELAY WITH 24DC COIL AND 2 SETS OF NORMALLY OPEN AND NORMALLY CLOSED (DPDT) CONTACTS RATED AT 120 VAC, 4 AMPS, INDUCTIVE. ADDRESSABLE RELAY AI AR R SLC TO NEXT DEVICE 120v SHUNT TRIP POWER TO BATTERY CHARGING SHUNT TRIP CIRCUIT BREAKER SLC TO NEXT DEVICE EMT (TYPICAL) SEE NOTES 1 & 2 BATTERY CHARGING SHUNT TRIP CONTROL CIRCUIT INTERFACE POINT ADDRESSABLE LOAD CONTROL FIELD RELAY WITH 24DC COIL AND 2 SETS OF NORMALLY OPEN AND NORMALLY CLOSED (DPDT) CONTACTS RATED AT 120 VAC, 4 AMPS, INDUCTIVE. ADDRESSABLE INTERFACE MODULE ADDRESSABLE RELAY GENERAL NOTES: A.PROVIDE MINIMUM 305X305X100MM DEEP NEMA 1 TERMINAL BOX WITH SCREW COVER (CONTRACTOR SHALL VERIFY REQUIRED BOX SIZE). LABEL "FIRE ALARM BATTERY CHARGER SHUNT TRIP CONNECTION" WITH ASSOCIATED ELEVATOR NUMBERS. B.LOCATE TERMINAL BOX, WITHIN THREE FEET OF ASSOCIATED SHUNT TRIP CIRCUIT BREAKER/DISCONNECT DEVICE. NO SCALE BATTERY CHARGER POWER SHUNT TRIP DETAIL 1 2 3 4 5 6 10 11 WATERFLOW SWITCH AC POWER FAILURE LOW BATTERY OPEN CIRCUIT GROUND CIRCUIT NOTIFICATION APPLIANCE CIRCUIT OPEN OR SHORT A ACTUATE COMMON ALARM SIGNAL INDICATOR ATRELEASING CONTROL PANELACTUATE COMMON SUPERVISORY SIGNAL INDICATORAT RELEASING CONTROL PANELACTUATE COMMON TROUBLE SIGNAL INDICATORAT RELEASING CONTROL PANELSOUND INTERNAL BUZZER AT RELEASING CONTROLPANEL (RCP)TEXT MESSAGE DISPLAY DEVICE TYPE & LOCATIONOF THE ACTIVATING DEVICES ON LCD OFRELEASING CONTROL PANEL (RCP)TRANSMIT FIRE ALARM SIGNAL TO BUILDING FACPACTIVATE GAS DETECTION AUDIBLE/VISUALNOTIFICATION APPLIANCES (RED STROBES)OPEN PREACTION SOLENOID VALVEB C D E F G H I CONTROL UNIT ANNUNCIATION SYSTEM OUTPUT INDICATING/CONTROLLED DEVICES SYSTEM INPUTS INITIATING DEVICES NOTIFICATION FIRE PROTECTION SYSTEM INPUT/OUTPUT MATRIX 9 J KTRANSMIT SUPERVISORY SIGNAL TO BUILDINGFACPCONTROL FUNCTIONS NO SCALE FIRE PROTECTION SYSTEM INPUT/OUTPUT MATRIX 7 8 PREACTION SMOKE DETECTOR TAMPER SWITCH LOW AIR PRESSURE SWITCH HYDROGEN GAS DETECTOR MANUAL PULL STATION OPEN PREACTION SPRINKLER VALVESHUNT BATTERY CHARGING1 F-500 2 F-500 4 F-500 ROD SIZE (A) B C RODTAKE-OUT (D)MIN. THREADLENGTH (E)PIPE SIZE A B C 212 12 5916 4 3 634 478 4 71316 512 5 9116 618 6 10716 61516 12 ALL SIZES ARE IN INCHES 2 12 412 314 112 4 3 114 3716 2916 1 21316 218 34 2716 17 8 12 38 218 11116 8 1234 838 38 38 38 38 38 38 38 38 5810 1514 91316 5812 1758 11316 D 3116 31516 438 5 51116 212 214 11316 13 8 118 1516 718 838 91116 E 3 212 212 312 312 312 212 212 212 212 212 212 212 212 MINIMUM ONE FULL THREAD OF ROD MUST BE EXPOSED CLEVIS HANGER ALL-THREAD ROD CROSS BOLT CLEVIS BOLT SPACER NO SCALE PIPE SUPPORT DETAIL3 F-500 FINISHED FLOOR 1" BALL VALVE NOT OVER 7'-0" ABOVE FINISHED FLOOR BRANCH LINE RETURN BEND FOR PREACTION SYSTEM EXTERIOR BUILDING WALL NO SCALE INSPECTOR TEST DETAIL5 F-500 TEMPORARY CONNECTION PLUG VALVE END WHEN NOT IN USE 12 CELLWATCH BATTERY MONITORING SYSTEM FAILURE TO EXISTING STAIRWELL DRAIN RISER 13 SUPPLY AIR DUCT VELOMETER - VELOCITY DROP ARCHIVE BAR CODEITHACA, NEW YORK Rhodes Hall UPS Replacement ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: P11874770 DATE: FACILITY: DESIGN: DRAWN: TMT TMT 2051 April 8, 2020 WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONSCORNELLUNIV E RSI TYFOUN DE D 5681AD FACILITIES ENGINEERING ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 GHD Project #11205715 GHD Consulting Services Inc. 5788 Widewaters Pkwy Syracuse NY 13214 USA T 1 315 802 0260 F 1 315 802 0450 RHODES HALL ISSUE FOR 95% REVIEW103/20/20 100% FOR CONSTRUCTION204/08/20 FIRE PROTECTION RISER DIAGRAM SCALE: NO SCALE F-601 FIRE PROTECTION RISER DIAGRAM BASEMENT PENTHOUSE FACP ANN ANN RCP IDC - ESS ROOM ALARM IDC - ESS ROOM SUPRVISORY EX TVSS 1 RISER DIAGRAM KEYED NOTES: TO 120 VAC POWER SOURCE 24 VDC POWER FROM RCP POWER CIRCUIT TO EACH HYDROGEN GAS DETECTOR HYDROGEN GAS DETECTION ALARM IDC HYDROGEN GAS DETECTION TROUBLE/FAULT IDC ESS ROOM SIGNALING LINE CIRCUIT TO BATTERY CHARGING SHUNT TRIP HYDROGEN GAS DETECTION NOTIFICATION APPLIANCE CIRCUIT EXISTING BUILDING NOTIFICATION APPLIANCE CIRCUIT EXTEND EXISTING BUILDING NOTIFICATION APPLIANCE CIRCUIT FOR NEW DEVICES PROVIDE CONTROL PANEL ADJACENT TO EXISTING BUILDING FIRE ALARM CONTROL PANEL TO RECEIVE ALARM, SUPERVISORY AND TROUBLE SIGNALS FROM THE PENTHOUSE RELEASING PANEL AND REPORTING ALARM SIGNAL THROUGH THE BUILDING FIRE ALARM CONTROL PANEL TO THE CAMPUS CENTRAL STATION. 2 3 4 5 6 1 AOM AIM AIM AIM SV TS LA WF S P S P S P S P AIM AIM H H H 2 3 4 5 S P S P S P S P 6 AOM AIM AR2 7 7 G H 8 8 IDC - GAS DETECTION ALARM IDC - ESS ROOM TROUBLE F H F H G H G H G H EOL EX EX F H F H EOL 9 10 EOL EOL EOL EOL EOLEOL EOL 10 9 F EX EX FACP 11 11 CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT E-001 11874770 GENERAL NOTES AND SYMBOL LEGENDS E. REICHARD ETR 2051 APRIL 8, 2020 ELECTRICAL SCOPE OF WORK 1.0 THIS PROJECT INCLUDES THE REPLACEMENT OF THE EXISTING 300KVA UPS SYSTEM WITH A NEW EATON 275KVA UPS SYSTEM, ADDING A MANUAL TRANSFER SWITCH FOR TOTAL BYPASS OF UPS, BATTERIES AND SBM. THE UPS, SBM, RECTIFIER PANEL AND GLOBAL BYPASS PANEL ARE TO BE PURCHASED FROM EATON AS A COMPLETE SYSTEM. THE CONTACT JIM CAVANAUGH AT SYRATEC EATON FOR QUOTE INFORMATION AND ORDERING OF EQUIPMENT - 315-263-0077. ALSO INCLUDED IN THE SCOPE IS THE REMOVAL OF EXISTING CONCRETE PADS. ELECTRICAL LEGEND LIGHTING LEGEND MOTOR 1'x4' LUMINAIRE HARDWIRED EQUIPMENT CONNECTION P-1A12 HOMERUN TO PANEL P-1A, CIRCUIT #12. FED FROM 20A -1P BREAKER IS INTENDED UNLESS NOTED OTHERWISE. RUN GREEN WIRE GROUND FOR ALL CIRCUITS. PROVIDE ONE GROUND PER CIRCUIT. EMERGENCY POWER OFF (EPO) GROUND ROD ELECTRODE DUPLEX RECEPTACLE WITH GFCI PROTECTION DUPLEX RECEPTACLE WITH AFCI PROTECTION QUAD RECEPTACLE LINETYPES LEGEND SPECIAL RECEPTACLE5-30R PANELBOARD JUNCTION BOX B = INSTALLED IN BASEBOARD TR = INSTALLED IN WOOD TRIM/CASEWORK/WAINSCOTT SR = SURFACE RACEWAY WP = WEATHERPROOF AC = AIR CONDITIONER X DUPLEX RECEPTACLE: DOUBLE DUPLEX RECEPTACLE MOTOR STARTER J 2'x4' LUMINAIRE CEILING MOUNTED LUMINAIRE EM LIGHTING BATTERY UNIT COMBO EXIT SIGN/EM LIGHTING BATTERY UNIT SINGLE FACE, WALL MOUNT EXIT SIGN DOUBLE FACE, WALL MOUNT EXIT SIGN SINGLE FACE, CEILING MOUNT EXIT SIGN DOUBLE FACE, CEILING MOUNT EXIT SIGN LIGHT SWITCH: SAFETY SWITCH (NON-FUSED) SAFETY SWITCH (FUSED) X 3 = 3-WAY SWITCH 4 = 4-WAY SWITCH D = DIMMER SWITCH O = WALL SWITCH OCCUPANCY SENSOR V = WALL SWITCH VACANCY SENSOR W = WIRELESS SWITCH S = WIRELESS SCENE SWITCH WIRELESS OCCUPANCY SENSOR WIRELESS DAYLIGHT SENSOR OS W DS 1'x2' LUMINAIRE FIRE ALARM LEGEND FIRE ALARM CONTROL PANEL BATTERY CABINET WATER FLOW SWITCH MUXPAD REMOTE ANNUNCIATOR D = DUCT SMOKE DETECTOR R = RELAY BASE BR = BEAM RECEIVER BT = BEAM TRANSMITTER SB = SOUNDER BASE SMOKE DETECTOR: TAMPER SWITCH AUDIBLE NOTIFICATION APPLIANCE FACP BATT MUX FAA NAC PANELNAC MANUAL PULL STATIONF S X F = FIXED TEMPERATURE R = RATE OF RISE R/F = COMBINATION RISE/FIXED TEMPERATURE HEAT DETECTOR: H X CARBON MONOXIDE DETECTORCO AM F XXcd C FS F S XXcd C TS ADDRESSABLE MODULE XXcd = CANDELA C = CEILING COMBO A/V NOTIFICATION APPLIANCE: XXcd = CANDELA C = CEILING VISUAL NOTIFICATION APPLIANCE: SUPPRESSION SYSTEM ELECTRICAL ABBREVIATIONS AC AIR CONDITIONER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AFI ARC FAULT INTERRUPTER AMM ADDRESSABLE MONITOR MODULE AOM ADDRESSABLE OUTPUT MODULE ARB AUXILIARY RELAY BOARD ATS AUTOMATIC TRANSFER SWITCH B BASEBOARD BKR BREAKER C CONDUIT CD CANDELA CKT CIRCUIT CR CONTROL RELAY EC ELECTRICAL CONTRACTOR EMT ELECTRICAL METALLIC TUBING EPO EMERGENCY POWER OFF STATION FAA FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FSD FIRE SMOKE DAMPER GAA GENERATOR ALARM ANNUNCIATOR GFI GROUND FAULT INTERRUPTER GND GROUND HP HORSEPOWER KW KILOWATT LC LIGHTING CONTACTOR LFMC LIQUID TIGHT FLEXIBLE METALLIC CONDUIT LTG LIGHTING MCB MAIN CIRCUIT BREAKER MLO MAIN LUG ONLY MTS MANUAL TRANSFER SWITCH NAC NOTIFICATION APPLIANCE CIRCUIT NIC NOT IN CONTRACT OE OVERHEAD ELECTRIC PC PHOTOCELL PM PLUGMOLD PP POWER PANEL PVC POLYVINYL CHLORIDE CONDUIT RGS RIGID GALVANIZED STEEL CONDUIT SR SURFACE RACEWAY ST SHUNT TRIP TM THERMAL MAGNETIC TR TRIM/CASEWORK/WAINSCOTT TSP TWISTED SHIELDED PAIR TYP TYPICAL UE UNDERGROUND ELECTRIC UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY V VOLTS VA VOLT AMPS WP WATERPROOF UNDERGROUND ELECTRICUE UNDERGROUND LIGHTINGUL OVERHEAD ELECTRICOE TO BE PROVIDED DEMOLITION / TO BE RELOCATED EXISTING TO REMAIN UNDERGROUND TELCOUC MOUNTING HEIGHTS CARD READER 48" TOP OF BOX LIGHT SWITCH 48" TOP OF BOX RECEPTACLE 18" TOP OF BOX DATA OUTLET 18" TOP OF BOX TV OUTLET 84" TOP OF BOX PHONE OUTLET 48" TOP OF BOX SAFETY SWITCH 60" CENTERLINE OF HANDLE MOTOR STARTER 60" CENTERLINE OF HANDLE PANELBOARD 72" TOP OF PANELBOARD MANUAL PULL STATION 48" OPERABLE HANDLE NOTIFICATION APPLIANCE 80" BOTTOM OF LENS DOOR HOLD OPEN COORDINATE IN FIELD EM BATTERY UNIT 96" BOTTOM OF UNIT EM REMOTE UNIT 102" BOTTOM OF UNIT EXIT SIGN 96" BOTTOM OF UNIT LIGHT POLE WITH LED LUMINAIRES, REFER TO PLANS FOR NUMBER AND CONFIGURATION OF HEADS GENERAL ELECTRICAL NOTES 1.0 ELECTRICAL SCHEMATICS INDICATED ON CONTRACT DOCUMENTS ARE DIAGRAMMATIC. IT IS NOT THE INTENT TO SHOW EXACT OR MOST EFFICIENT ROUTING. VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ON SITE. ANY CONFLICTS BETWEEN CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALL BE BROUGHT TO CORNELL'S PROJECT MANAGER FOR RESOLUTION BEFORE WORK PROCEEDS. 2.0 ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOINING AREAS FROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE AND DISPOSE OF WASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISES FREE OF DEBRIS FROM THE EXECUTION OF WORK. DELIVER A FINAL PRODUCT THAT IS CLEAN AND OPERABLE. 3.0 FIRE STOP ELECTRICAL PENETRATIONS THROUGH FIRE RATED WALLS AND/OR FLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTION OF THE MATERIAL PENETRATED. 4.0 WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACT DOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHOD OF INSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FOR APPROVAL PRIOR TO ORDERING ANY MATERIALS OR COMMENCING EXECUTION OF WORK. 5.0 GROUNDING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 250. PROVIDE EQUIPMENT GROUND CONDUCTOR WITH EACH BRANCH CIRCUIT INDICATED ON CONTRACT DOCUMENTS. EQUIPMENT GROUND CONDUCTOR SHALL BE ROUTED WITH ASSOCIATED PHASE CONDUCTORS. 6.0 PROVIDE A NEW TYPED PANELBOARD DIRECTORY FOR EACH PANELBOARD. LABEL ALL NEW DEVICE FACEPLATES WITH SOURCE AND CIRCUIT NUMBER. PROVIDE PERMANENT LABEL ON SWITCHING DEVICES INDICATING EQUIPMENT SERVICE AND INVENTORY NUMBERS. COORDINATE EQUIPMENT INVENTORY NUMBERS WITH CORNELL UNIVERSITY'S MECHANICAL SHOP, 255-8667. 7.0 CIRCUITS RATED 20-AMP, 120 VOLT SHALL CONTAIN SEPARATE NEUTRAL CONDUCTORS. 8.0 CONDUCTORS SHALL BE A MINIMUM OF 12AWG, STRANDED COPPER, 600VAC, 90 DEGREE C, TYPE THHN/THWN-2 FOR DRY AREAS AND XHHW/THWN-2 FOR WET AREAS. 9.0 CONDUITS SHALL BE A MINIMUM OF 3/4 INCHES DIAMETER. CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT) AND SURFACE MOUNTED UNLESS NOTED OTHERWISE. 10.0 AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OF RESPECTIVE PANELBOARD. SIZE AS INDICATED. 11.0 PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDE SUPPORT HANGERS FOR CONDUIT AS NEEDED. 12.0 INSTALL RACEWAY SYSTEMS ENSURING PROPER ACCESS TO EQUIPMENT AND DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. RACEWAYS THAT ARE NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. GENERAL ELECTRICAL DEMOLITION NOTES 1.0 ELECTRICAL EQUIPMENT SHOWN DASHED ON DEMOLITION DRAWINGS, INCLUDING ASSOCIATED ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS, AND OTHER APPURTENANCES NOT SHOWN, SHALL BE DISCONNECTED AND REMOVED. REMOVE ASSOCIATED BRANCH CIRCUITRY TO SOURCE, UNLESS NOTED OTHERWISE. 2.0 EXISTING RACEWAYS AND DEVICE BACKBOXES NOT INTERFERRING WITH NEW WORK SHALL BE REUSED WHERE POSSIBLE. 3.0 PROVIDE JUNCTION BOXES, RACEWAYS, AND WIRING TO MODIFY/EXTEND EXISTING SYSTEMS AND CIRCUITS FED DOWNSTREAM OF ELECTRICAL EQUIPMENT SHOWN TO BE DEMOLISHED. 4.0 CUT DEMOLISHED CONDUITS INSTALLED THRU WALLS AND FLOORS FLUSH WITH THE SURFACE AND PATCH PENETRATIONS (FIRESTOP IF LOCATED ON A FIRE RATED SURFACE). PATCH AND PAINT SURFACES IN EXPOSED AREAS TO MATCH SURROUNDING MATERIALS, FINISHES, AND COLORS. 5.0 PROVIDE BLANK COVERPLATES ON UNUSED BACKBOXES REMAINING FROM DEMOLITION NOT SPECIFIED TO BE INFILLED. 6.0 EXISTING EQUIPMENT SHOWN TO REMAIN SHALL BE PROTECTED DURING CONSTRUCTION. 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION UPS SYSTEM DESCRIPTION THE UPS SYSTEM IS A REDUNDANT SYSTEM WITH TWO MODULES THAT BACK EACH OTHER UP IN CASE OF FAILURE. THE ENTIRE SYSTEM FROM EATON CONSISTS OF THE FOLLOWING COMPONENTS: 1. TWO (2) EATON UPS 9395HP 275 UPM’S WITH WEB/SNMP, CAN BRIDGE & INDUSTRIAL RELAY CARD 2. FOUR (4) EATON VRLA BATTERY CABINETS –TWO (2) FOR EACH UPS (12.1 MINUTES FULL LOAD RUNTIME) 3. PARALLEL TIE CABINET WITH 2 BREAKER MAINTENANCE BYPASS (AKA SBM) 4. CELLWATCH BATTERY MONITORING WITH THERMAL RUNAWAY AND THERMAL CABINET SENSOR 5. GLOBAL BYPASS PANEL 6. RECTIFIER DISTRIBUTION PANEL WITH SURGE PROTECTION IT IS THE CONTRACTOR ’S RESPONSIBILITY TO PROVIDE THIS SYSTEM AND EQUIPMENT ALONG WITH THE POWER AND CONTROL WIRING AND TERMINATIONS BETWEEN ALL THE COMPONENTS EXCEPT THE CELL WATCH WIRING TO THE BATTERY CABINETS WHICH IS BY EATON. THE CONTRACTOR PROVIDES ALL CONDUIT INSTALLATIONS. IN ADDITION TO THE UPS’S PROVIDING REDUNDANCY TO ONE ANOTHER, THERE ARE TWO BYPASS OPTIONS FOR THE SYSTEM. THE BYPASS IN THE SBM ALLOWS THE BYPASS OF THE UPS AND THE GLOBAL BYPASS ALLOWS THE UPS’S, SBM AND ATS’S TO BE BYPASSED ALL AT ONE TIME. THE SBM BYPASS CONFIGURATION IS AN INTERLOCK SCHEME FOR CLOSED TRANSITION (MAKE BEFORE BREAK) BETWEEN THE MIS AND MBP BREAKERS WHICH CONSISTS OF A TWO-KEY INTERLOCK WITH A SOLENOID RELEASE AND INDICATOR LAMP. REFER TO THE ONE-LINE DIAGRAMS FOR INTERLOCK DESIGNATIONS. THE GLOBAL BYPASS CONFIGURATION IS ALSO A TWO KEY INTERLOCK SCHEME FOR CLOSED TRANSITION (MAKE BEFORE BREAK) BETWEEN THE GBB AND SIS BREAKERS WITH SOLENOID KEY RELEASE AND INDICATOR LAMP. IN ORDER FOR A TRANSFER TO OCCUR BETWEEN GBB AND SIS, THE ATS-3 NORMALLY OPEN CONTACT MUST CLOSE WHEN THE ATS-3 IS IN EMERGENCY FEED POSITION, AND THE MBP BREAKER IN THE SBM TIE CABINET IS CLOSED (VIA THE N.O. AUXILIARY CONTACT). REFER TO THE ONE-LINE DIAGRAMS FOR INTERLOCK DESIGNATIONS. EXISTING UPS EXISTING UPS EXISTING SBM EXISTING BATTERIES SUB SS-B1 ATS-3 ATS-2 ATS-5 DP-MG1 DP-MG2 EXISTING OVERHEAD J-BOX #1 EXISTING OVERHEAD J-BOX #2 SUB SS-B2 LINE OF BEAM OVERHEAD TO GENERATOR ROOM 3" EMT 4" EMT 1 2 D E F C F.8 G 4321 SUB SS-B1 SUB SS-B2 NEW UPS #1 NEW UPS BATTERIES (STORE OUTSIDE ELECTRICAL ROOM)NEW UPS #2NEW SBM NEW GLOBAL BYPASS PANEL LINE OF BEAM OVERHEAD ATS-3 ATS-2 ATS-5 EXISTING OVERHEAD J-BOX #1 1 2 3 4 5 6 7 NEW RECTIFIER PANEL D E F C F.8 G 4321 DP-MG1 DP-MG2 8 8 2 NEW CELL WATCH COTROL/IBMU ENCLOSURES ELP-P 9 CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT E-101 11874770 EXISTING AND PHASE 1 PLANS E. REICHARD ETR 2051 April 8, 2020 0 4 8 16 SCALE: 1/8"=1'-0" SCALE:1/8" = 1'-0"1 PENTHOUSE EXISTING FLOOR PLAN SCALE:1/8" = 1'-0"2 PENTHOUSE PHASE 1 FLOOR PLAN # #E-101 KEYED DEMOLITION NOTES 1 REMOVE EXISTING CONCRETE PADS. WET CONCRETE AND TENT AREA TO MINIMIZE DUST AND KEEP EXISTING EQUIPMENT CLEAN. SMOOTH FLOOR DOWN TO MATCH EXISTING FLOOR. WIPE DOWN AND CLEAN EQUIPMENT FROM ANY DUST CREATED FROM THE CONCRETE REMOVAL. 2 REMOVE EXISTING CONCRETE PAD FROM NORTH EDGE TO EDGE OF EXISTING SBM TO ALLOW FOR PLACEMENT OF STRUCTURAL BEAMS ACROSS THE FLOOR. E-101 KEYED CONSTRUCTION NOTES 1 INSTALL BEAMS ON FLOOR IN LOCATION INDICATED. REFER TO STRUCTURAL DRAWING FOR BEAM AND INSTALLATION DETAILS. 2 PROVIDE EATON 600 AMP RECTIFIER DISTRIBUTION PANEL. PANEL TO BE INSTALLED IN FRONT OF HORIZONTAL BEAM TO ALLOW FOR CONDUIT INSTALLATION IN/OUT OF TOP OF ENCLOSURE. INSTALL ON FLOOR MOUNTED STEEL STRUT. PROVIDE CONDUIT FROM PANEL TO ATS-5 LOCATION. CONDUIT AND CONDUCTORS TO BE TERMINATED IN NEXT PHASE. REFER TO ONE-LINE DIAGRAM FOR CONDUIT AND CONDUCTOR SIZES. 3 PROVIDE TWO (2) EATON 9395HP 275KVA/275KW UPS MODULES FOR PARALLEL REDUNDANT SYSTEM. INSTALL MODULES DIRECTLY ON FINISHED FLOOR. PROVIDE CONDUIT AND CONDUCTORS FOR UPS RECTIFIER AND BYPASS FEEDS FROM RECTIFIER DISTRIBUTION PANEL TO BOTH UPS MODULES. REFER TO ONE-LINE DIAGRAM FOR CONDUIT AND CONDUCTOR SIZES. 4 PROVIDE EATON SBM PARALLEL TIE CABINET WITH TWO BREAKER MAINTENANCE BYPASS IN LOCATION INDICATED. CABINET TO BE INSTALLED IN FRONT OF HORIZONTAL BEAM TO ALLOW FOR CONDUIT INSTALLATION IN/OUT OF TOP OF CABINET. PROVIDE CONDUIT AND CONDUCTORS FROM UPS MODULES TO THE SBM CABINET. REFER TO ONE-LINE DIAGRAM FOR CONDUIT AND CONDUCTOR SIZES. 5 PROVIDE NEW EATON 1200A GLOBAL BYPASS PANELBOARD. PANEL TO BE INSTALLED IN FRONT OF HORIZONTAL BEAM TO ALLOW FOR CONDUIT INSTALLATION IN/OUT OF TOP OF ENCLOSURE. PROVIDE CONDUIT AND CONDUCTORS FROM THE SBM CABINET TO THE GLOBAL BYPASS PANEL. REFER TO ONE-LINE DIAGRAM FOR CONDUIT AND CONDUCTOR SIZES. 6 PROVIDE CONDUIT FROM GLOBAL BYPASS PANELBOARD TO ABOVE EXISTING SBM BYPASS CABINET. CONDUIT AND CONDUCTORS TO BE TERMINATED AT PHASE 3. REFER TO ONE-LINE DIAGRAM FOR CONDUIT AND CONDUCTOR SIZES. 7 PROVIDE UPS VRLA BATTERIES FOR UPS MODULES. STORE OUTSIDE OF ELECTRICAL ROOM DURING CONSTRUCTION AND INSTALL BATTERIES IN PHASES IDENTIFIED. 8 PROVIDE TWO 3” EMT CONDUITS WITH PULL STRING FROM GLOBAL BYPASS PANELBOARD TO EACH PANEL DP-MG1 AND PANEL DP-MG2 FOR FUTURE FEEDS. PROVIDE TWO NEW SPECTRA RMS SKHA36AT0800 BREAKER WITH 500A PLUG, PADLOCK AND HARDWARE MOUNTING KITS. TURN BREAKERS OVER TO THE FACILITY FOR FUTURE INSTALLATION. 9 PROVIDE CELLWATCH CONTROL PANEL AND IBMU IN LOCATION INDICATED. MOUNT ON STRUT AT 5’ AFF. PROVIDE NEMA 5-20R RECEPTACLE ON WALL FOR CELLWATCH/IBMU POWER. PROVIDE 2-#12 & 1#12 THHN GND IN ¾” EMT FROM PANEL ELP-P 20A SPARE BREAKER IN CIRCUIT SPACE #4 TO RECEPTACLE. PROVIDE 500VA UPS WITH MINIMUM 15 MINUTE RUNTIME ON WALL NEXT TO RECEPTACLE AND PLUG INTO RECEPTACLE. PROVIDE POWER TO CONTROL PANEL/IBMU FROM 500VA UPS WITH 12-2 SO TYPE CORD AND PROVIDE NEMA 5-15P PLUG. 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION SUB SS-B1 SUB SS-B2 EXISTING OVERHEAD J-BOX #2 NEW UPS #1 NEW UPS #2 UPS #1 3" EMT LINE OF BEAM OVERHEAD NEW 12"X12"X6" OVERHEAD J-BOX #3 NEW SBM NEW GLOBAL WRAP PANEL ATS-3 ATS-2 ATS-5 EXISTING OVERHEAD J-BOX #1 1 2 3 4 5 6 7 8 9 10 11 5 7 5 4 D E F C F.8 G 4321 5 6 NEW 24"x24" PULL BOX PANEL DS-EG SECTION 2 GENERATOR ROOM PANEL DS-EG SECTION 1 12"x12" WIREWAY 12 13 14 15 16 3 6 7 11 12 12 12 14 NEW CELL WATCH & IBMU # 0 4 8 16 SCALE: 1/8"=1'-0"CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT E-102 11874770 PHASE 2 PLAN E. REICHARD ETR 2051 APRIL 8, 2020 SCALE:1/8" = 1'-0"1 PENTHOUSE PHASE 2 FLOOR PLAN E-102 KEYED CONSTRUCTION NOTES 1 OPEN UPS #2 CIRCUIT BREAKER IN UPS MODULE. 2 OPEN UPS #2 BATTERY CIRCUIT BREAKER TO DISCONNECT BATTERY POWER. 3 OPEN 500A BREAKER IN PANEL DS-EG IN GENERATOR ROOM FOR EMERGENCY FEED TO ATS #5. LOCK BREAKER IN OPEN POSITION. 4 OPEN 500A FUSED SWITCH IN SWITCHBOARD SS-B2 FOR NORMAL FEED TO ATS #5. LOCK SWITCH IN OPEN POSITION. 5 DISCONNECT CONDUCTORS FROM LINE SIDE OF UPS #2. REMOVE CONDUIT AND CONDUCTORS BACK ATS-5. 6 START GENERATOR AND SWITCH ATS-3 TO EMERGENCY POWER. OPEN 500A SWITCH IN SWITCHBOARD SS-B2 FOR NORMAL FEED TO ATS-3. 7 OPEN 4000A MAIN SWITCH IN SS-B2. TIE SWITCH TO REMAIN OPEN. WHILE BUSS IS DE-ENERGIZED, REMOVE AND DISPOSE OF EXISTING 2 SETS OF 250 KCMIL CONDUCTORS FROM ATS-5 BACK TO SS-B2. DISCONNECT REMAINING POWER AND CONTROL CONDUCTORS AND SAVE FOR REUSE. REMOVE AND DISPOSE OF ATS-5 AND REPLACE WITH A 600 AMP CLOSED TRANSITION ATS (NEW ATS-5). RECONNECT POWER AND CONTROL CONDUCTORS SAVED FROM REMOVAL. 8 PROVIDE NEW CONDUCTORS FROM SWITCH IN SS-B2 TO ATS-5. REFER TO ONE-LINE DIAGRAM FOR CONDUCTOR SIZES. REUSE EXISTING 3” CONDUIT. REPLACE THE 500 AMP FUSES WITH 600 AMP FUSES (TYPE KRP-C). SWITCH TO REMAIN LOCKED OPEN. 9 MAKE FINAL CONDUIT AND CONDUCTOR CONNECTIONS FROM RECTIFIER POWER PANEL TO NEW ATS-5. 10 CLOSE MAIN SWITCH AND RE-ENERGIZE SS-B2. 11 CLOSE 500 AMP SWITCH FOR ATS-3. TRANSFER ATS-3 BACK TO NORMAL POWER. 12 PROVIDE CONDUIT AND CONDUCTORS FROM GLOBAL BYPASS PANEL TO PANEL DS-EG FOR NEW BYPASS FEED. INSTALL CONDUIT AND CONDUCTOR INTO GENERATOR ROOM PRIOR TO SHUTDOWN. REFER TO ONE-LINE DIAGRAM FOR CONDUIT AND CONDUCTOR SIZES. FINAL CONNECTIONS AND TERMINATIONS TO BE MADE DURING EMERGENCY POWER SHUTDOWN. 13 OPEN GENERATOR BREAKER. DISCONNECT AND REMOVE THE 2 SETS OF EXISTING EMERGENCY FEEDERS BETWEEN ATS-5 AND THE 500 AMP BREAKER IN PANEL DS-EG. REMOVE 500 AMP BREAKER AND SAVE FOR BYPASS FEEDER CONNECTION. SHUNT WIRING CIRCUIT TO REMAIN FOR USE WITH NEW BREAKER. PROVIDE 600 AMP SPECTRA RMS BREAKER WITH SHUNT TRIP IN PLACE OF 500 AMP BREAKER. CONNECT SHUNT WIRING TO NEW BREAKER SHUNT LEADS. PROVIDE NEW FEEDER FROM 600 AMP BREAKER TO ATS-5. PROVIDE 12”X12”X6’ WIREWAY BETWEEN PANEL SECTIONS OF DS-EG. REINSTALL 500 AMP BREAKER WITH LUGS FACING WIREWAY. EXTEND SHUNT CIRCUITRY TO THE 500A BREAKER SHUNT LEADS AS NECESSARY. FINALIZE FEED FROM GLOBAL BYPASS PANEL AND TERMINATE TO THE 500 AMP BREAKER. DURING THIS TIME THE BUILDING WILL BE WITHOUT GENERATOR POWER AND CANNOT HAVE OCCUPANTS. COORDINATE THIS EMERGENCY POWER SHUTDOWN WITH THE FACILITY. 14 CLOSE GENERATOR BREAKER AND 600 AMP BREAKER IN PANEL DS-EG. CLOSE 600 AMP FUSED SWITCH FOR NORMAL POWER TO ATS-5. 15 REMOVE AND DISPOSE OF BATTERIES #3 AND #4 FOR EXISTING UPS #2. 16 INSTALL NEW BATTERIES #3 AND #4 FOR NEW UPS MODULE #2. PROVIDE CONDUIT AND CONDUCTORS FROM BATTERY CABINET TO UPS MODULE. CLOSE RECTIFIER PANEL MAIN BREAKER AND 600A BREAKER FEEDING UPS #2 AND PERFORM LOAD TEST PRIOR TO TRANSFERRING BUILDING LOAD TO UPS. BREAKERS FOR UPS #1 TO REMAIN OPEN UNTIL LOAD TEST IS TO BE PERFORMED. 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION SUB SS-B1 SUB SS-B2 LINE OF BEAM OVERHEAD NEW UPS #1 NEW UPS #2 3" EMT ATS-3 ATS-5 EXISTING OVERHEAD J-BOX #1 2 3 4 5 6 7 8 9 10 11 1 D E F C F.8 G 4321 5 6 12 6 8 11 11 NEW GLOBAL BYPASS PANEL NEW SBM NEW UPS NEW BATTERY CABINETS NEW ATS-5 ATS-3 NEW RECTIFIER DISTRIBUTION PANEL NEW BEAMS ON FLOOR CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT E-103 11874770 PHASE 3 PLAN AND PERSPECTIVE E. REICHARD EWK 2051 APRIL 8, 2020 0 4 8 16 SCALE: 1/8"=1'-0" SCALE:1/8" = 1'-0"1 PENTHOUSE PHASE 3 FLOOR PLAN SCALE:2 PERSPECTIVE VIEW FINAL E-103 KEYED CONSTRUCTION NOTES 1 EXERCISE BREAKERS MBP/MIS MULTIPLE TIMES PRIOR TO MAKING THE CUT OVER TO NEW FEED. OPEN MBP CIRCUIT BREAKER IN EXISITING SBM CABINET. 2 OPEN THE MAIN SWITCH FOR SS-B1. OPEN THE 800 AMP SWITCH AT SS-B1 TO THE ALTERNATE BYPASS FEED TO MBP. REMOVE CONDUIT AND CONDUCTORS BACK TO SWITCH AND DISPOSE OF. CLOSE MAIN SWITCH TO RE-ENERGIZE SS-B1. 3 FINALIZE THE INSTALLATION OF THE CONDUIT AND CONDUCTORS FROM THE GLOBAL BYPASS PANEL TO THE EXISTING SBM. CONNECT FEED TO THE MBP CIRCUIT BREAKER IN THE EXISTING SBM CABINET. 4 CLOSE MOB2 CIRCUIT BREAKER IN NEW SBM CABINET. CLOSE RECTIFIER PANEL MAIN BREAKER AND BREAKERS FEEDING UPS #2. 5 CLOSE MBP CIRCUIT BREAKER IN EXISITING SBM CABINET, OPEN MIS BREAKER TO TRANSFER LOAD TO NEW UPS #2. 6 OPEN CBS BREAKER IN THE EXISTING SBM CABINET. OPEN FBP AND CBP BREAKERS. START GENERATOR AND TRANSFER ATS-3 AND ATS-5 TO EMERGENCY POWER. OPEN MAIN SWITCH TO SS-B2. OPEN 800 AMP SWITCH, REMOVE AND DISPOSE OF STATIC BYPASS FEED BACK TO SS-B1. CLOSE MAIN SWITCH TO SS-B2 AND LABEL SWITCH “SPARE”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’S AND SBM. 12 INSTALL NEW BATTERIES FOR UPS #1. PROVIDE CONDUIT AND CONDUCTORS FROM BATTERIES TO UPS MODULE. CLOSE RECTIFIER PANEL BREAKERS FEEDING UPS #1. TRANSFER ATS-3 AND ATS-5 TO EMERGENCY POWER, SWITCH SBM INTO BYPASS. OPEN BREAKERS IN RECTIFIER PANEL FEEDING UPS #2. PERFORM LOAD TESTING ON UPS #1. ONCE COMPLETE, CLOSE BREAKERS IN RECTIFIER PANEL FEEDING UPS #2, CLOSE MOB1 BREAKER. SWITCH BACK TO UPS POWER AND TRANSFER ATS-3 AND ATS-5 TO NORMAL POWER. # 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION EQUIPMENT PATH OF TRAVEL GENERATOR ROOM D E F C F.8 G 4321 5 6 B 7 REMOVE AND REINSTALL CMU BELOW DOUBLE DOOR TO BRING EQUIPMENT IN AND OUT OF ELECTRICAL ROOM.CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT E-104 11874770 PENTHOUSE PATH OF TRAVEL E. REICHARD ETR 2051 APRIL 8, 2020 SCALE:1/8" = 1'-0"1 PENTHOUSE FLOOR PLAN PATH OF TRAVEL 0 4 8 16 SCALE: 1/8"=1'-0" 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION E N L BATTERY BATTERY TO MV SWITCH 600AF800AS 400AF600AS 500AF800AS 400AF600AS 400AF600AS 500AF1200AS 400AF600AS 500AF800AS 800AF1600AS 4000AF4000AS 800AF 500AT 800AF 500AT 800AF 600AT E N L 800A/3P800A/3P 800A/3P 800A/3P800A/3P 800AF1600AS 400AF600AS 500AF800AS 400AF600AS 400AF600AS 500AF800AS ---AF600AS 500AF1200AS 4000AF4000AS 3000AF3000AS 2500-KVA PRI: 13.2-KV SEC: 480Y/277V 2500-KVA PRI: 13.2-KV SEC: 480Y/277V GUNIT 800-KW 800AF 400AT 800AF 400AT 800AF 400AT SPARE 800AF 400AT 800AF 400AT 800AF 400AT SPARE DP-MG1 SECT 1 800A, 480/277V, 3Ø, 4W DP-MG1 SECT 2 800A, 480/277V, 3Ø, 4W DP-MG2 SECT 2 800A, 480/277V, 3Ø, 4W DP-MG2 SECT 1 800A, 480/277V, 3Ø, 4W SPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACE DP-CC62 400A, 480/277V, 3Ø, 4W DP-CC72 400A, 480/277V, 3Ø, 4W DP-CC61 400A, 480/277V, 3Ø, 4W DP-CC71 400A, 480/277V, 3Ø, 4W SPARE SS-B2 4000A 480/277V, 3Ø, 4W SS-B1 4000A 480/277V, 3Ø, 4W DS-EG 1200A 480/277V, 3Ø, 4W ATS-3 ATS-5 UPS MODULE #1 300KVA #1 #2 EXISTING 800A SBM CABINET SPACE BATTERY BATTERY UPS MODULE #2 300KVA #3 #4 MBP CBS (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT J. BOX #1 J. BOX #2 J. BOX #1 J. BOX #1 UPS #2 BREAKER UPS #1 BREAKER 1 2 1 3 4 5 (3) SETS 4-250 KCMIL (3) SETS 4-250 KCMIL (3) SETS 4-250 KCMIL(2) SETS 4-250 KCMIL (2) SETS 4-250 KCMIL 4 CB-1 CB-1 500A/3P UPS MODULE #1 275KVA UPS MODULE #2 275KVA NEW 500A SBM CABINET 500A/3P 500A/3P (2) SETS OF 3-250KCMIL & 1-#2 GND IN 3" EMT 600A/3P 600A/3P 500A/3P 500A/3P 500A/3P GLOBAL BYPASS DISTRIBTION PANEL 500A/3P500A/3P 800AF 400AT 1000AF 1200AT 500A/3P 500A/3P600A/3P (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT RECTIFIER DISTRIBUTION PANEL 480V, 3Ø, 3W 65KAIC 480V, 3Ø, 3W, 65KAIC 2 CD DC BA AB SKRU A SKRU C 500A/3P 480V, 3Ø, 3W 65KAIC MBP (NO) MIS (NC) MOB 1 MOB 2MOB 1LB1 SIS (NC) GBB (NO) 60A/3P SPD 120KA CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT E-301 11874770 PHASE 1 ONE-LINE DIAGRAM E. REICHARD ETR 2051 April 8, 2020 SCALE: NO SCALE 1 ONE-LINE DIAGRAM PHASE 1 E-301 KEYED PHASE 1 NOTES 1 PROVIDE EATON 600 AMP RECTIFIER DISTRIBUTION PANEL. PROVIDE CONDUIT FROM PANEL TO ATS-5 LOCATION. CONDUIT AND CONDUCTORS TO BE TERMINATED IN NEXT PHASE. 2 PROVIDE TWO (2) EATON 9395HP 275KVA/275KW UPS MODULES FOR PARALLEL REDUNDANT SYSTEM. PROVIDE CONDUIT AND CONDUCTORS FOR UPS RECTIFIER AND BYPASS FEEDS FROM RECTIFIER DISTRIBUTION PANEL TO BOTH UPS MODULES. 3 PROVIDE EATON SBM PARALLEL TIE CABINET WITH TWO BREAKER MAINTENANCE BYPASS. PROVIDE CONDUIT AND CONDUCTORS FROM UPS MODULES TO THE SBM CABINET. 4 PROVIDE NEW EATON 1200A GLOBAL BYPASS PANELBOARD. PROVIDE CONDUIT AND CONDUCTORS FROM THE SBM CABINET TO THE GLOBAL BYPASS PANEL. 5 PROVIDE CONDUIT FROM GLOBAL BYPASS PANELBOARD TO ABOVE EXISTING SBM BYPASS CABINET. CONDUIT AND CONDUCTORS TO BE TERMINATED AT PHASE 3. # 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION E N L BATTERY BATTERY TO MV SWITCH 600AF800AS 400AF600AS 500AF800AS 400AF600AS 400AF600AS 400AF600AS 500AF800AS 800AF1600AS 4000AF4000AS E N L 800A/3P800A/3P 800A/3P 800A/3P800A/3P 800AF1600AS 400AF600AS 500AF800AS 400AF600AS 400AF600AS 500AF800AS ---AF600AS 500AF1200AS 4000AF4000AS 3000AF3000AS 2500-KVA PRI: 13.2-KV SEC: 480Y/277V 2500-KVA PRI: 13.2-KV SEC: 480Y/277V 800AF 400AT 800AF 400AT 800AF 400AT SPARE 800AF 400AT 800AF 400AT 800AF 400AT SPARE DP-MG1 SECT 1 800A, 480/277V, 3Ø, 4W DP-MG1 SECT 2 800A, 480/277V, 3Ø, 4W DP-MG2 SECT 2 800A, 480/277V, 3Ø, 4W DP-MG2 SECT 1 800A, 480/277V, 3Ø, 4W SPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACE DP-CC62 400A, 480/277V, 3Ø, 4W DP-CC72 400A, 480/277V, 3Ø, 4W DP-CC61 400A, 480/277V, 3Ø, 4W DP-CC71 400A, 480/277V, 3Ø, 4W SPARE SS-B2 4000A 480/277V, 3Ø, 4W SS-B1 4000A 480/277V, 3Ø, 4W ATS-3 NEW ATS-5 UPS MODULE #1 300KVA #1 #2 EXISTING 800A SBM CABINET SPACE UPS MODULE #2 300KVA #3 #4 MBP CBSMIS FBP CBP EXISTING J-BOX #1 BATTERY BATTERY 1 2 3 4 5 6 7 8 9 10 11 (3) SETS 4-250 KCMIL (3) SETS 4-250 KCMIL 12 CB-1 BATTERY BATTERY CB-1 500A/3P 500A/3P UPS MODULE #1 275KVA UPS MODULE #2 275KVA NEW 500A SBM CABINET 500A/3P 500A/3P 600A/3P 600A/3P 500A/3P 500A/3P 500A/3P600A/3P 500A/3P 500A/3P GLOBAL BYPASS DISTRIBTION PANEL 500A/3P500A/3P 800AF 400AT 800AF 500AT 800AF 500AT 800AF 600AT 800AF 600AT GUNIT 800-KW DS-EG 1200A 480/277V, 3Ø, 4W 1000AF 1200AT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-250KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN EXISTING 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN EXISTING 3" EMT (3) SETS 4-250 KCMIL EXISTING J-BOX #1 #3 #4 13 14 15 16 (2) SETS OF 2-#500 KCMIL & 1-#2 GND IN 3" EMT 14 14 13 6 6 12 RECITIFIER DISTRIBUTION PANEL 600AF1200AS 8 CD DC BA AB SKRU ASKRU C MBP (NO) MIS (NC) MOB 2MOB 1LB1SIS (NC) GBB (NO)CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT E-302 11874770 PHASE 2 ONE-LINE DIAGRAM E. REICHARD ETR 2051 APRIL 8, 2020 SCALE: NO SCALE 1 ONE-LINE DIAGRAM PHASE 2 #E-302 KEYED PHASE 2 NOTES 1 OPEN UPS #2 CIRCUIT BREAKER IN UPS MODULE. 2 OPEN UPS #2 BATTERY CIRCUIT BREAKER TO DISCONNECT BATTERY POWER. 3 OPEN 500A BREAKER IN PANEL DS-EG IN GENERATOR ROOM FOR EMERGENCY FEED TO ATS #5. LOCK BREAKER IN OPEN POSITION. 4 OPEN 500A FUSED SWITCH IN SWITCHBOARD SS-B2 FOR NORMAL FEED TO ATS #5. LOCK SWITCH IN OPEN POSITION. 5 DISCONNECT CONDUCTORS FROM LINE AND LOAD SIDE OF UPS #2. REMOVE CONDUIT AND CONDUCTORS BACK ATS-5. 6 START GENERATOR AND SWITCH ATS-3 TO EMERGENCY POWER. OPEN 500A SWITCH IN SWITCHBOARD SS-B2 FOR NORMAL FEED TO ATS-3. 7 OPEN 4000A MAIN SWITCH IN SS-B2. TIE SWITCH TO REMAIN OPEN. WHILE BUSS IS DE-ENERGIZED, REMOVE AND DISPOSE OF EXISTING 2 SETS OF 250 KCMIL CONDUCTORS FROM ATS-5 BACK TO SS-B2. REMOVE AND DISPOSE OF ATS-5 AND REPLACE WITH A 600 AMP CLOSED TRANSITION ATS (NEW ATS-5). 8 PROVIDE NEW CONDUCTORS FROM SWITCH IN SS-B2 TO ATS-5. REUSE EXISTING 3” CONDUIT. REPLACE THE 500 AMP FUSES WITH 600 AMP FUSES (TYPE KRP-C). RETURN OLD FUSES TO CORNELL. SWITCH TO REMAIN LOCKED OPEN. 9 MAKE FINAL CONDUIT AND CONDUCTOR CONNECTIONS FROM RECITFIER POWER PANEL TO NEW ATS-5. 10 CLOSE MAIN SWITCH AND RE-ENERGIZE SS-B2. 11 CLOSE 500 AMP SWITCH FOR ATS-3. TRANSFER ATS-3 BACK TO NORMAL POWER. 12 PROVIDE CONDUIT AND CONDUCTORS FROM GLOBAL BYPASS PANEL TO PANEL DS-EG FOR NEW BYPASS FEED. INSTALL CONDUIT AND CONDUCTOR INTO GENERATOR ROOM PRIOR TO SHUTDOWN. FINAL CONNECTIONS AND TERMINATIONS TO BE MADE DURING EMERGENCY POWER SHUTDOWN. 13 OPEN GENERATOR BREAKER. DISCONNECT AND REMOVE THE 2 SETS OF EXISTING EMERGENCY FEEDERS BETWEEN ATS-5 AND THE 500 AMP BREAKER IN PANEL DS-EG. REMOVE 500 AMP BREAKER AND SAVE FOR BYPASS FEEDER CONNECTION. SHUNT WIRING CIRCUIT TO REMAIN FOR USE WITH NEW BREAKER. PROVIDE 600 AMP SPECTRA RMS BREAKER WITH SHUNT TRIP IN PLACE OF 500 AMP BREAKER. CONNECT SHUNT WIRING TO NEW BREAKER SHUNT LEADS. PROVIDE NEW FEEDER FROM 600 AMP BREAKER TO ATS-5. PROVIDE 12”X12”X6’ WIREWAY BETWEEN PANEL SECTIONS OF DS-EG. REINSTALL 500 AMP BREAKER WITH LUGS FACING WIREWAY. EXTEND SHUNT CIRCUITRY TO THE 500A BREAKER SHUNT LEADS AS NECESSARY. FINALIZE FEED FROM GLOBAL BYPASS PANEL AND TERMINATE TO THE 500 AMP BREAKER. DURING THIS TIME THE BUILDING WILL BE WITHOUT GENERATOR POWER AND CANNOT HAVE OCCUPANTS. COORDINATE THIS EMERGENCY POWER SHUTDOWN WITH THE FACILITY. 14 CLOSE GENERATOR BREAKER AND 600 AMP BREAKER IN PANEL DS-EG. CLOSE 600 AMP FUSED SWITCH FOR NORMAL POWER TO ATS-5. 15 REMOVE AND DISPOSE OF BATTERIES #3 AND #4 FOR EXISTING UPS #2. 16 INSTALL NEW BATTERIES #3 AND #4 FOR NEW UPS MODULE #2. PROVIDE CONDUIT AND CONDUCTORS FROM BATTERY CABINET TO UPS MODULE. CLOSE RECTIFIER PANEL MAIN BREAKER AND 600A BREAKER FEEDING UPS #2 AND PERFORM LOAD TEST PRIOR TO TRANSFERRING BUILDING LOAD TO UPS. BREAKERS FOR UPS #1 TO REMAIN OPEN UNTIL LOAD TEST IS TO BE PERFORMED. 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION E N L BATTERY BATTERY TO MV SWITCH 600AF800AS 400AF600AS 500AF800AS 400AF600AS 400AF600AS 500AF1200AS 400AF600AS 500AF800AS 800AF1600AS 4000AF4000AS E N L 800AF1600AS 400AF600AS 500AF800AS 400AF600AS 400AF600AS 500AF800AS ---AF600AS 500AF1200AS 4000AF4000AS 3000AF3000AS 2500-KVA PRI: 13.2-KV SEC: 480Y/277V 2500-KVA PRI: 13.2-KV SEC: 480Y/277V 800AF 400AT 800AF 400AT 800AF 400AT SPARE 800AF 400AT 800AF 400AT 800AF 400AT SPARE DP-MG1 SECT 1 800A, 480/277V, 3Ø, 4W DP-MG1 SECT 2 800A, 480/277V, 3Ø, 4W DP-MG2 SECT 2 800A, 480/277V, 3Ø, 4W DP-MG2 SECT 1 800A, 480/277V, 3Ø, 4W SPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACE DP-CC62 400A, 480/277V, 3Ø, 4W DP-CC72 400A, 480/277V, 3Ø, 4W DP-CC61 400A, 480/277V, 3Ø, 4W DP-CC71 400A, 480/277V, 3Ø, 4W SPARE SS-B2 4000A 480/277V, 3Ø, 4W SS-B1 4000A 480/277V, 3Ø, 4W ATS-3 UPS MODULE #1 300KVA #1 #2 SPACE EXISTING J-BOX #1 ATS-5 (2) SETS OF 3-250KCMIL & 1-#2 GND IN 3" EMT (3) SETS 4-250 KCMIL (2) SETS OF 3-350KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-350KCMIL & 1-#1 GND IN 3" EMT (3) SETS 4-250 KCMIL 1 2 2 3 4 5 6 7 7 7 7 8 9 10 11 12 BATTERY BATTERY CB-1 BATTERY BATTERY CB-1 500A/3P UPS MODULE #1 300KVA UPS MODULE #2 300KVA NEW 500A SBM CABINET 500A/3P 500A/3P 600A/3P 600A/3P 500A/3P 500A/3P 500A/3P600A/3P 800A/3P800A/3P 800A/3P 800A/3P800A/3P MBP CBSMIS FBP CBP 8 12 500A/3P 500A/3P GLOBAL BYPASS DISTRIBTION PANEL 500A/3P500A/3P 800AF 400AT 800AF 500AT 800AF 500AT 800AF 600AT 800AF 600AT GUNIT 800-KW DS-EG 1200A 480/277V, 3Ø, 4W 1000AF 1200AT #1 #2 #3 #4 (2) SETS OF 3-250KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-250KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-500KCMIL & 1-#1/0 GND IN 4" EMT (3) SETS 4-250 KCMIL (2) SETS OF 3-250KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN EXISTING 3" EMT (3) SETS 4-250 KCMIL RECITIFIER DISTRIBUTION PANEL (2) SETS OF 2-#500 KCMIL & 1-#2 GND IN 3" EMT 11 2 CD DC BA AB SKRU ASKRU C 500A/3P MBP (NO) MIS (NC) MOB 2MOB 1LB1 SIS (NC) GBB (NO)CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT E-303 11874770 PHASE 3 ONE-LINE DIAGRAM E. REICHARD ETR 2051 APRIL 8, 2020 SCALE: NO SCALE 1 ONE-LINE DIAGRAM PHASE 3 E-303 KEYED PHASE 3 NOTES 1 EXERCISE BREAKER MBP MULTIPLE TIMES PRIOR TO MAKING THE CUT OVER TO NEW FEED. OPEN MBP CIRCUIT BREAKER IN EXISITING SBM CABINET. 2 OPEN THE MAIN SWITCH FOR SS-B1. OPEN THE 800 AMP SWITCH AT SS-B1 TO THE ALTERNATE BYPASS FEED TO MBP. PULL CONDUCTORS BACK TO SWITCH AND DISPOSE OF. CLOSE MAIN SWITCH TO RE-ENERGIZE SS-B1. 3 FINALIZE THE INSTALLATION OF THE CONDUIT AND CONDUCTORS FROM THE GLOBAL BYPASS PANEL TO THE EXISTING SBM. CONNECT FEED TO THE MBP CIRCUIT BREAKER IN THE EXISTING SBM CABINET. 4 CLOSE MOB2 CIRCUIT BREAKER IN NEW SBM CABINET. CLOSE RECTIFIER PANEL MAIN BREAKER AND BREAKERS FEEDING UPS #2. 5 CLOSE MBP CIRCUIT BREAKER IN EXISITING SBM CABINET, OPEN MIS BREAKER TO TRANSFER LOAD TO NEW UPS #2. 6 OPEN CBS BREAKER IN THE EXISTING SBM CABINET. OPEN FBP AND CBP BREAKERS. START GENERATOR AND TRANSFER ATS-3 AND ATS-5 TO EMERGENCY POWER. OPEN MAIN SWITCH TO SS-B2. OPEN 800 AMP SWITCH, REMOVE AND DISPOSE OF STATIC BYPASS FEED BACK TO SS-B1. CLOSE MAIN SWITCH TO SS-B2 AND LABEL SWITCH “SPARE”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Ø, 4W DP-MG1 SECT 2 800A, 480/277V, 3Ø, 4W DP-MG2 SECT 2 800A, 480/277V, 3Ø, 4W DP-MG2 SECT 1 800A, 480/277V, 3Ø, 4W SPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACE DP-CC62 400A, 480/277V, 3Ø, 4W DP-CC72 400A, 480/277V, 3Ø, 4W DP-CC61 400A, 480/277V, 3Ø, 4W DP-CC71 400A, 480/277V, 3Ø, 4W SPARE SS-B2 4000A 480/277V, 3Ø, 4W SS-B1 4000A 480/277V, 3Ø, 4W SS-B1 1200A 480/277V, 3Ø, 4W ATS-3 NEW ATS-5 SPACE BATTERY BATTERY CB-1 BATTERY BATTERY CB-1 500A/3P 500A/3P UPS MODULE #1 275KVA UPS MODULE #2 275KVA#1 #2 NEW 500A SBM CABINET 500A/3P 500A/3P #3 #4 MBP MIS 800A/3P 800A/3P 800A/3P EXISTING 800A SBM CABINET CBS 600A/3P 600A/3P 600A/3P SPARESPARE RECTIFIER DISTRIBUTION PANEL 500A/3P 500A/3P 500A/3P GLOBAL BYPASS DISTRIBTION PANEL 500A/3P 1000AF 1200AT 500A/3P 500A/3P 500A/3P (3) SETS 4-250 KCMIL (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-250KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN EXISTING 3" EMT(2) SETS OF 3-#350 KCMIL & 1-#1 GND IN EXISTING 3" EMT (3) SETS 4-250 KCMIL CD DC BA AB SKRU A SKRU C MBP (NO) MIS (NC) MOB 2MOB 1LB1 SIS (NC) GBB (NO)CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT E-304 11874770 FINAL ONE-LINE DIAGRAM E. REICHARD ETR 2051 APRIL 8, 2020 SCALE:12" = 1'-0"1 ONE-LINE DIAGRAM FINAL 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION E N L E N L ATS-3 NEW ATS-5 BATTERY BATTERY CB-1 BATTERY BATTERY CB-1 500A/3P 500A/3P UPS MODULE #1 300KVA UPS MODULE #2 300KVA#1 #2 500A SBM CABINET 500A/3P 500A/3P #3 #4 500A/3P500A/3P 500A/3P GLOBAL BYPASS DISTRIBTION PANEL 500A/3P500A/3P CD DC BA AB SKRU A SKRU C J CA CD4CD2 CB1 CD1 CE1 CE2 CB CD3 CF CB2 CC CA1 CG CG TO COL. D1 TO COL. D1 CW CW IBMU CELL WATCH PANEL CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT E-305 11874770 CONTROL RISER DIAGRAM E. REICHARD ETR 2051 April 8, 2020 SCALE:12" = 1'-0"1 CONTROL RISER DIAGRAM CONTROL WIRING LEGEND CA 1 - #14 TWISTED PAIR IN ½” EMT CA1 1 - #14 TWISTED PAIR IN ½” EMT CB 2 - #14 TWISTED PAIR IN ½” EMT (CB1 & CB2) CB1 1 - #14 TWISTED PAIR IN ½” EMT CB2 1 - #14 TWISTED PAIR IN ½” EMT CC 1 - #20 TWISTED SHIELDED PAIR INSIDE UPS CABINETS CD1 2 - #14 TWISTED PAIR IN ½” EMT CD2 2 - #14 TWISTED PAIR IN ½” EMT WITH CD1 CD3 2 - #14 TWISTED PAIR IN ½” EMT CD4 2 - #14 TWISTED PAIR IN ½” EMT WITH CD3 CE1 6 - #14 TWISTED PAIR IN ¾” EMT CE2 6 - #14 TWISTED PAIR IN ¾” EMT CF 1 - #14 TWISTED PAIR IN ½” EMT CG CAT6 IN 3/4" EMT W/BUSHING AT END - CAT6 BY CORNELL (COORDINATE WITH RICK POLARO) CW 1" EMT WITH PULLSTRING FROM EACH BATTERY SET TO CELLWATCH PANEL. PROVIDE 1" EMT WITH PULL STRING BETWEEN IBMU AND CELLWATCH CONTROL PANEL. EATON TO PULL CONTROL WIRING AND TERMINATE. NOTE: REFER TO WIRE CHARTS IN SPECIFICATIONS FOR ADDITIONAL INFORMATION 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION