Loading...
HomeMy WebLinkAbout019.0_E-304 FINAL ONE LINE DIAGRAME N L TO MV SWITCH 600AF 800AS 400AF 600AS 500AF 800AS 400AF 600AS 400AF 600AS 600AF 1200AS 400AF 600AS 500AF 800AS 800AF 1600AS 4000AF 4000AS 800AF 400AT 800AF 500AT 800AF 500AT 800AF 600AT 800AF 600AT E N L 800A/3P 800A/3P 800AF 1600AS 400AF 600AS 500AF 800AS 400AF 600AS 400AF 600AS 500AF 800AS ---AF 600AS 500AF 1200AS 4000AF 4000AS 3000AF 3000AS 2500-KVA PRI: 13.2-KV SEC: 480Y/277V 2500-KVA PRI: 13.2-KV SEC: 480Y/277V GUNIT 800-KW 800AF 400AT 800AF 400AT 800AF 400AT SPARE 800AF 400AT 800AF 400AT 800AF 400AT SPARE DP-MG1 SECT 1 800A, 480/277V, 3Ø, 4W DP-MG1 SECT 2 800A, 480/277V, 3Ø, 4W DP-MG2 SECT 2 800A, 480/277V, 3Ø, 4W DP-MG2 SECT 1 800A, 480/277V, 3Ø, 4W SPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACE DP-CC62 400A, 480/277V, 3Ø, 4W DP-CC72 400A, 480/277V, 3Ø, 4W DP-CC61 400A, 480/277V, 3Ø, 4W DP-CC71 400A, 480/277V, 3Ø, 4W SPARE SS-B2 4000A 480/277V, 3Ø, 4W SS-B1 4000A 480/277V, 3Ø, 4W SS-B1 1200A 480/277V, 3Ø, 4W ATS-3 NEW ATS-5 SPACE BATTERY BATTERY CB-1 BATTERY BATTERY CB-1 500A/3P 500A/3P UPS MODULE #1 275KVA UPS MODULE #2 275KVA#1 #2 NEW 500A SBM CABINET 500A/3P 500A/3P #3 #4 MBP MIS 800A/3P 800A/3P 800A/3P EXISTING 800A SBM CABINET CBS 600A/3P 600A/3P 600A/3P SPARESPARE RECTIFIER DISTRIBUTION PANEL 500A/3P 500A/3P 500A/3P GLOBAL BYPASS DISTRIBTION PANEL 500A/3P 1000AF 1200AT 500A/3P 500A/3P 500A/3P (3) SETS 4-250 KCMIL (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-250KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN EXISTING 3" EMT(2) SETS OF 3-#350 KCMIL & 1-#1 GND IN EXISTING 3" EMT (3) SETS 4-250 KCMIL CD DC BA AB SKRU A SKRU C MBP (NO) MIS (NC) MOB 2MOB 1LB1 SIS (NC) GBB (NO)CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT E-304 11874770 FINAL ONE-LINE DIAGRAM E. REICHARD ETR 2051 APRIL 8, 2020 SCALE:12" = 1'-0"1 ONE-LINE DIAGRAM FINAL 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION