HomeMy WebLinkAbout018.0_E-303 PHASE 3 ONE LINE DIAGRAME N L BATTERY BATTERY TO MV SWITCH 600AF800AS 400AF600AS 500AF800AS 400AF600AS 400AF600AS 500AF1200AS 400AF600AS 500AF800AS 800AF1600AS 4000AF4000AS E N L 800AF1600AS 400AF600AS 500AF800AS 400AF600AS 400AF600AS 500AF800AS ---AF600AS 500AF1200AS 4000AF4000AS 3000AF3000AS 2500-KVA PRI: 13.2-KV SEC: 480Y/277V 2500-KVA PRI: 13.2-KV SEC: 480Y/277V 800AF 400AT 800AF 400AT 800AF 400AT SPARE 800AF 400AT 800AF 400AT 800AF 400AT SPARE DP-MG1 SECT 1 800A, 480/277V, 3Ø, 4W DP-MG1 SECT 2 800A, 480/277V, 3Ø, 4W DP-MG2 SECT 2 800A, 480/277V, 3Ø, 4W DP-MG2 SECT 1 800A, 480/277V, 3Ø, 4W SPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACE DP-CC62 400A, 480/277V, 3Ø, 4W DP-CC72 400A, 480/277V, 3Ø, 4W DP-CC61 400A, 480/277V, 3Ø, 4W DP-CC71 400A, 480/277V, 3Ø, 4W SPARE SS-B2 4000A 480/277V, 3Ø, 4W SS-B1 4000A 480/277V, 3Ø, 4W ATS-3 UPS MODULE #1 300KVA #1 #2 SPACE EXISTING J-BOX #1 ATS-5 (2) SETS OF 3-250KCMIL & 1-#2 GND IN 3" EMT (3) SETS 4-250 KCMIL (2) SETS OF 3-350KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-350KCMIL & 1-#1 GND IN 3" EMT (3) SETS 4-250 KCMIL 1 2 2 3 4 5 6 7 7 7 7 8 9 10 11 12 BATTERY BATTERY CB-1 BATTERY BATTERY CB-1 500A/3P UPS MODULE #1 300KVA UPS MODULE #2 300KVA NEW 500A SBM CABINET 500A/3P 500A/3P 600A/3P 600A/3P 500A/3P 500A/3P 500A/3P600A/3P 800A/3P800A/3P 800A/3P 800A/3P800A/3P MBP CBSMIS FBP CBP 8 12 500A/3P 500A/3P GLOBAL BYPASS DISTRIBTION PANEL 500A/3P500A/3P 800AF 400AT 800AF 500AT 800AF 500AT 800AF 600AT 800AF 600AT GUNIT 800-KW DS-EG 1200A 480/277V, 3Ø, 4W 1000AF 1200AT #1 #2 #3 #4 (2) SETS OF 3-250KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-250KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-500KCMIL & 1-#1/0 GND IN 4" EMT (3) SETS 4-250 KCMIL (2) SETS OF 3-250KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#250 KCMIL & 1-#2 GND IN 3" EMT (2) SETS OF 3-#350 KCMIL & 1-#1 GND IN EXISTING 3" EMT (3) SETS 4-250 KCMIL RECITIFIER DISTRIBUTION PANEL (2) SETS OF 2-#500 KCMIL & 1-#2 GND IN 3" EMT 11 2 CD DC BA AB SKRU ASKRU C 500A/3P MBP (NO) MIS (NC) MOB 2MOB 1LB1 SIS (NC) GBB (NO)CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT E-303 11874770 PHASE 3 ONE-LINE DIAGRAM E. REICHARD ETR 2051 APRIL 8, 2020 SCALE: NO SCALE 1 ONE-LINE DIAGRAM PHASE 3 E-303 KEYED PHASE 3 NOTES 1 EXERCISE BREAKER MBP MULTIPLE TIMES PRIOR TO MAKING THE CUT OVER TO NEW FEED. OPEN MBP CIRCUIT BREAKER IN EXISITING SBM CABINET. 2 OPEN THE MAIN SWITCH FOR SS-B1. OPEN THE 800 AMP SWITCH AT SS-B1 TO THE ALTERNATE BYPASS FEED TO MBP. PULL CONDUCTORS BACK TO SWITCH AND DISPOSE OF. CLOSE MAIN SWITCH TO RE-ENERGIZE SS-B1. 3 FINALIZE THE INSTALLATION OF THE CONDUIT AND CONDUCTORS FROM THE GLOBAL BYPASS PANEL TO THE EXISTING SBM. CONNECT FEED TO THE MBP CIRCUIT BREAKER IN THE EXISTING SBM CABINET. 4 CLOSE MOB2 CIRCUIT BREAKER IN NEW SBM CABINET. CLOSE RECTIFIER PANEL MAIN BREAKER AND BREAKERS FEEDING UPS #2. 5 CLOSE MBP CIRCUIT BREAKER IN EXISITING SBM CABINET, OPEN MIS BREAKER TO TRANSFER LOAD TO NEW UPS #2. 6 OPEN CBS BREAKER IN THE EXISTING SBM CABINET. OPEN FBP AND CBP BREAKERS. START GENERATOR AND TRANSFER ATS-3 AND ATS-5 TO EMERGENCY POWER. OPEN MAIN SWITCH TO SS-B2. OPEN 800 AMP SWITCH, REMOVE AND DISPOSE OF STATIC BYPASS FEED BACK TO SS-B1. CLOSE MAIN SWITCH TO SS-B2 AND LABEL SWITCH “SPARE”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