HomeMy WebLinkAbout012.0_E-101 EXISTING AND PHASE 1 PLANSEXISTING UPS EXISTING UPS EXISTING SBM EXISTING BATTERIES SUB SS-B1 ATS-3 ATS-2 ATS-5 DP-MG1 DP-MG2 EXISTING OVERHEAD J-BOX #1 EXISTING OVERHEAD J-BOX #2 SUB SS-B2 LINE OF BEAM OVERHEAD TO GENERATOR ROOM 3" EMT 4" EMT 1 2 D E F C F.8 G 4321 SUB SS-B1 SUB SS-B2 NEW UPS #1 NEW UPS BATTERIES (STORE OUTSIDE ELECTRICAL ROOM)NEW UPS #2NEW SBM NEW GLOBAL BYPASS PANEL LINE OF BEAM OVERHEAD ATS-3 ATS-2 ATS-5 EXISTING OVERHEAD J-BOX #1 1 2 3 4 5 6 7 NEW RECTIFIER PANEL D E F C F.8 G 4321 DP-MG1 DP-MG2 8 8 2 NEW CELL WATCH COTROL/IBMU ENCLOSURES ELP-P 9 CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT E-101 11874770 EXISTING AND PHASE 1 PLANS E. REICHARD ETR 2051 April 8, 2020 0 4 8 16 SCALE: 1/8"=1'-0" SCALE:1/8" = 1'-0"1 PENTHOUSE EXISTING FLOOR PLAN SCALE:1/8" = 1'-0"2 PENTHOUSE PHASE 1 FLOOR PLAN # #E-101 KEYED DEMOLITION NOTES 1 REMOVE EXISTING CONCRETE PADS. WET CONCRETE AND TENT AREA TO MINIMIZE DUST AND KEEP EXISTING EQUIPMENT CLEAN. SMOOTH FLOOR DOWN TO MATCH EXISTING FLOOR. WIPE DOWN AND CLEAN EQUIPMENT FROM ANY DUST CREATED FROM THE CONCRETE REMOVAL. 2 REMOVE EXISTING CONCRETE PAD FROM NORTH EDGE TO EDGE OF EXISTING SBM TO ALLOW FOR PLACEMENT OF STRUCTURAL BEAMS ACROSS THE FLOOR. E-101 KEYED CONSTRUCTION NOTES 1 INSTALL BEAMS ON FLOOR IN LOCATION INDICATED. REFER TO STRUCTURAL DRAWING FOR BEAM AND INSTALLATION DETAILS. 2 PROVIDE EATON 600 AMP RECTIFIER DISTRIBUTION PANEL. PANEL TO BE INSTALLED IN FRONT OF HORIZONTAL BEAM TO ALLOW FOR CONDUIT INSTALLATION IN/OUT OF TOP OF ENCLOSURE. INSTALL ON FLOOR MOUNTED STEEL STRUT. PROVIDE CONDUIT FROM PANEL TO ATS-5 LOCATION. CONDUIT AND CONDUCTORS TO BE TERMINATED IN NEXT PHASE. REFER TO ONE-LINE DIAGRAM FOR CONDUIT AND CONDUCTOR SIZES. 3 PROVIDE TWO (2) EATON 9395HP 275KVA/275KW UPS MODULES FOR PARALLEL REDUNDANT SYSTEM. INSTALL MODULES DIRECTLY ON FINISHED FLOOR. PROVIDE CONDUIT AND CONDUCTORS FOR UPS RECTIFIER AND BYPASS FEEDS FROM RECTIFIER DISTRIBUTION PANEL TO BOTH UPS MODULES. REFER TO ONE-LINE DIAGRAM FOR CONDUIT AND CONDUCTOR SIZES. 4 PROVIDE EATON SBM PARALLEL TIE CABINET WITH TWO BREAKER MAINTENANCE BYPASS IN LOCATION INDICATED. CABINET TO BE INSTALLED IN FRONT OF HORIZONTAL BEAM TO ALLOW FOR CONDUIT INSTALLATION IN/OUT OF TOP OF CABINET. PROVIDE CONDUIT AND CONDUCTORS FROM UPS MODULES TO THE SBM CABINET. REFER TO ONE-LINE DIAGRAM FOR CONDUIT AND CONDUCTOR SIZES. 5 PROVIDE NEW EATON 1200A GLOBAL BYPASS PANELBOARD. PANEL TO BE INSTALLED IN FRONT OF HORIZONTAL BEAM TO ALLOW FOR CONDUIT INSTALLATION IN/OUT OF TOP OF ENCLOSURE. PROVIDE CONDUIT AND CONDUCTORS FROM THE SBM CABINET TO THE GLOBAL BYPASS PANEL. REFER TO ONE-LINE DIAGRAM FOR CONDUIT AND CONDUCTOR SIZES. 6 PROVIDE CONDUIT FROM GLOBAL BYPASS PANELBOARD TO ABOVE EXISTING SBM BYPASS CABINET. CONDUIT AND CONDUCTORS TO BE TERMINATED AT PHASE 3. REFER TO ONE-LINE DIAGRAM FOR CONDUIT AND CONDUCTOR SIZES. 7 PROVIDE UPS VRLA BATTERIES FOR UPS MODULES. STORE OUTSIDE OF ELECTRICAL ROOM DURING CONSTRUCTION AND INSTALL BATTERIES IN PHASES IDENTIFIED. 8 PROVIDE TWO 3” EMT CONDUITS WITH PULL STRING FROM GLOBAL BYPASS PANELBOARD TO EACH PANEL DP-MG1 AND PANEL DP-MG2 FOR FUTURE FEEDS. PROVIDE TWO NEW SPECTRA RMS SKHA36AT0800 BREAKER WITH 500A PLUG, PADLOCK AND HARDWARE MOUNTING KITS. TURN BREAKERS OVER TO THE FACILITY FOR FUTURE INSTALLATION. 9 PROVIDE CELLWATCH CONTROL PANEL AND IBMU IN LOCATION INDICATED. MOUNT ON STRUT AT 5’ AFF. PROVIDE NEMA 5-20R RECEPTACLE ON WALL FOR CELLWATCH/IBMU POWER. PROVIDE 2-#12 & 1#12 THHN GND IN ¾” EMT FROM PANEL ELP-P 20A SPARE BREAKER IN CIRCUIT SPACE #4 TO RECEPTACLE. PROVIDE 500VA UPS WITH MINIMUM 15 MINUTE RUNTIME ON WALL NEXT TO RECEPTACLE AND PLUG INTO RECEPTACLE. PROVIDE POWER TO CONTROL PANEL/IBMU FROM 500VA UPS WITH 12-2 SO TYPE CORD AND PROVIDE NEMA 5-15P PLUG. 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION