HomeMy WebLinkAbout007.0_F-102 BASEMENT FIRE PROTECTION PLANUP UP RAMP UP B0069 B10 B20 B0064 B0066 B50 B0067 B0068 B60 B0073 B0071 B0072 B0020 B0021 B0070 B0004 B0003 B0074 B0065 B40 B30 B0075 B18B31 B33 B35 B37 B0063 B0062 B0061 F A C P ANNANNEX EX EXFACP ARCHIVE BAR CODEITHACA, NEW YORK Rhodes Hall UPS Replacement ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: P11874770 DATE: FACILITY: DESIGN: DRAWN: TMT TMT 2051 April 8, 2020 WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONSCORNELLUNIV E RSI TYFOUN DE D 5681AD FACILITIES ENGINEERING ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 GHD Project #11205715 GHD Consulting Services Inc. 5788 Widewaters Pkwy Syracuse NY 13214 USA T 1 315 802 0260 F 1 315 802 0450 RHODES HALL ISSUE FOR 95% REVIEW103/20/20 100% FOR CONSTRUCTION204/08/20 BASEMENT FIRE PROTECTION PLAN SCALE: 3/32" = 1'-0" 0 SCALE 3/32"=1'-0" AT ORIGINAL SIZE 16'-0"12'-0"8'-0"4'-0" GENERAL NOTES: A. B. C. INSTALL ALL CONDUIT EXPOSED IN AREAS WITH NO FINISHED CEILINGS UNLESS OTHERWISE NOTED. INSTALL ALL WIRING AND CONDUIT WITH THE REQUIRED SUPPORT/HANGERS. INSTALL ALL SUPPORTS FROM THE BUILDING STRUCTURE. FIRE STOP ALL PENETRATIONS THROUGH RATED WALLS, FLOORS AND CEILINGS. F-102 BASEMENT FIRE PROTECTION PLAN EXISTING FIRE PUMP LOCATION FOR HYDRAULIC CALCULATION PURPOSES EXISTING 6-INCH STANDPIPE FIRE ALARM CONDUIT UP TO PENTHOUSE FIRE ALARM SUBPANEL KEYED NOTES: 2-HOUR CIRCUIT INTEGRITY FIRE ALARM CABLING SHALL BE INSTALLED WITHIN EMT CONDUIT. LOCATION OF VERTICAL CONDUIT RUNS SHALL BE COORDINATED WITH BUILDING PERSONNEL. IF A COMMON VERTICAL CONDUIT LOCATION IS FOUND, IT SHALL BE UTILIZED. PROVIDE NEW FCI E3 FACP ADJACENT TO THE EXISTING FCI 72C FACP TO RECEIVE ALARM, SUPERVISORY AND TROUBLE SIGNALS FROM THE PENTHOUSE RELEASING PANEL AND REPORTING ALARM SIGNALS THROUGH THE EXISTING MAIN FACP TO THE CAMPUS CENTRAL STATION AT BARTON HALL. PROVIDE AN ADDRESSABLE MODULE AND RECIRCUIT ONE EXISTING BASEMENT FLOOR FIRE ALARM ZONE THROUGH IT TO THE NEW FACP. CONNECT THE NEW FACP TO THE NEW SPARE ZONE IN THE EXISTING FACP. 1 2 2 1 2 3 3