HomeMy WebLinkAbout005.0_F-001 SYMB, GENERAL NOTES, ABBREVARCHIVE BAR CODEITHACA, NEW YORK Rhodes Hall UPS Replacement ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: P11874770 DATE: FACILITY: DESIGN: DRAWN: TMT TMT 2051 April 8, 2020 WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONSCORNELLUNIV E RSI TYFOUN DE D 5681AD FACILITIES ENGINEERING ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 GHD Project #11205715 GHD Consulting Services Inc. 5788 Widewaters Pkwy Syracuse NY 13214 USA T 1 315 802 0260 F 1 315 802 0450 RHODES HALL ISSUE FOR 95% REVIEW103/20/20 100% FOR CONSTRUCTION204/08/20 F-001 SYMBOL LIST, GENERAL NOTES AND ABBREVIATION LIST FIRE PROTECTION SYMBOL LIST MANUAL PULL STATION. MOUNTING HEIGHT: +48" AFF (TO CENTER) SMOKE SENSOR, PHOTOELECTRIC, CEILING MOUNTED FIRE ALARM CONTROL PANEL FIRE ALARM GENERAL NOTES: 1.THE SYSTEM SHALL INCLUDE ALL WIRING, RACEWAYS, PULL BOXES, TERMINAL CABINETS, OUTLET AND MOUNTING BOXES, CONTROL EQUIPMENT, ALARM, AND SUPERVISORY SIGNAL INITIATING DEVICES, ALARM NOTIFICATION APPLIANCES, INTERFACE EQUIPMENT, AND OTHER ACCESSORIES AND MISCELLANEOUS ITEMS INCLUDING SOFTWARE, SYSTEM PROGRAMMING, TESTING AND CONSTRUCTION PERMITS REQUIRED FOR A COMPLETE OPERATING SYSTEM EVEN THOUGH EACH ITEM IS NOT SPECIFICALLY MENTIONED OR DESCRIBED. PROVIDE SYSTEM COMPLETE AND READY FOR OPERATION. THE SYSTEM MUST COMPLY WITH THE 2015 INTERNATIONAL BUILDING CODE (IBC) WITH THE 2017 NYS UNIFORM CODE SUPPLEMENT. 2.PROVIDE ALL WIRING FROM APPLIANCE TERMINAL TO APPLIANCE TERMINAL. PROVIDE CONDUCTORS THAT ARE TERMINATED, SPLICED, OR OTHERWISE INTERRUPTED IN ANY ENCLOSURE, CABINET, MOUNTING, OR JUNCTION BOX CONNECTED TO SCREW-TYPE TERMINAL BLOCKS. WIRE NUTS AND SIMILAR DEVICES ARE PROHIBITED. 3.PROVIDE ALL FIRE ALARM CIRCUITS SUPERVISED UNLESS NOTED OTHERWISE, AS FOLLOWS IN ACCORDANCE WITH NFPA 72 (2013): ·INITIATING DEVICE CIRCUITS (IDC)- CLASS B ·NOTIFICATION APPLIANCE CIRCUITS (NAC)- CLASS B, SYNCHRONIZED ·SIGNALING LINE CIRCUITS (SLC)- CLASS B 4.PROVIDE SMOKE DETECTORS A MINIMUM OF 3 FEET FROM EXISTING AIR DIFFUSERS. 5.PROVIDE VISUAL WARNING STROBE/AUDIBLE NOTIFICATION APPLIANCES TO ACHIEVE MAXIMUM AUDIBILITY AND VISIBILITY IN ACCORDANCE WITH NFPA 72 GUIDELINES. PROVIDE CARE IN LOCATING VISUAL WARNING STROBE APPLIANCES TO ENSURE VISIBILITY AND AVOID OBSTRUCTIONS. 6.LABEL ALL ADDRESSABLE INPUT/OUTPUT FIRE ALARM COVER PLATES AND APPLIANCES (INCLUDING HORNS, STROBES, SMOKE SENSORS, HEAT SENSORS, MANUAL PULL STATIONS, ADDRESSABLE MODULES, ETC.) WITH THEIR ADDRESS UTILIZING A LABELING MACHINE. HAND WRITTEN LABELS MUST NOT BE USED. ADDRESS MUST INCLUDE NAC OR SLC NUMBER FOLLOWED BY APPLIANCE NUMBER. EACH SLC FIELD APPLIANCE ADDRESS MUST MATCH THE FIRE ALARM DISPLAY ADDRESS. 7.UNLESS OTHERWISE NOTED THE PROJECT ELECTRICAL CONDUIT STANDARD IS ELECTRICAL METALLIC TUBING (EMT) AND PROVIDED THROUGHOUT THE PROJECT. PROVIDE ALL WIRING IN CONDUIT WHERE WIRES WOULD OTHERWISE BE EXPOSED. WIRING MAY BE CONCEALED WITHIN WALLS AND CEILINGS WHERE APPLICABLE. 8.FLEXIBLE METAL CONDUIT (FMC) IS LIMITED TO 5 FEET AND SECURED PER THE NATIONAL ELECTRIC CODE (2014). FMC IS PERMITTED FOR DEVICES LOCATED ON FIRE SUPPRESSION EQUIPMENT ONLY SUCH AS FLOW/PRESSURE SWITCHES, SOLENOIDS AND TAMPER SWITCHES. 9.PROVIDE CONDUIT AS UNOBTRUSIVELY AS POSSIBLE, AS CLOSE AS POSSIBLE TO FLOOR/ CEILING SLAB AND PARALLEL AND AT RIGHT ANGLES TO STRUCTURAL ELEMENTS. 10.PROVIDE ELECTRICAL BOXES AS FOLLOWS: UNLESS OTHERWISE NOTED PROVIDE CAST METAL BELL TYPE BOXES WITH THREADED HUBS ON EXPOSED WORK, EXCEPT WHERE FACTORY BOXES ARE PROVIDED. CONCEALED BOXES MAY BE STAMPED STEEL BOXES. PROVIDE TERMINAL CABINETS OF SOLID WALL CONSTRUCTION WITH NO FACTORY CONDUIT KNOCK OUTS. 11.PAINT ALL CONDUIT, FIRE ALARM JUNCTION BOXES AND COVERS RED IN UNFINISHED AREAS. 12.CORE DRILL PENETRATIONS IN MASONRY WALLS AND FLOOR/CEILING SLABS. 13.BOTH EXPOSED AND CONCEALED CONDUIT INCLUDING RISERS UP TO 2 INCHES IN DIAMETER MUST UTILIZE COMPRESSION TYPE STEEL FITTINGS AND CONNECTORS. UNLESS OTHERWISE NOTED PROVIDE ALL CONDUIT 3/4 INCH MINIMUM TRADE SIZE. PROVIDE VERTICAL RISERS ONE INCH DIAMETER MINIMUM. PROVIDE PLENUM RATED WIRING CONDUCTORS (TYPE FPLP) WHEN FLEX CONDUIT IS UTILIZED. PROVIDE SOLID COPPER WIRING CONDUCTORS INSTALLED IN CONDUIT FOR THE FOLLOWING CIRCUITS (AT MINIMUM): ·FIRE ALARM INITIATING DEVICE CIRCUITS (IDC) - 14/2 AWG ·FIRE ALARM SIGNALING LINE CIRCUITS (SLC) - 16/2 AWG TWISTED PAIR ·FIRE ALARM VISUAL NOTIFICATION APPLIANCES - 12/2 AWG. ·120 VAC - PRIMARY POWER - NO. 12 AWG, THHN/THWN 600VAC INSULATED PROVIDE ALL WIRING UL LISTED FOR ITS INTENDED USE. 14.SECURE ALL NECESSARY CONSTRUCTION PERMITS, INSPECTIONS AND FINAL SYSTEM ACCEPTANCE. 15.CONTRACT DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND USED IN CONJUNCTION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION. CONTRACTOR MUST COORDINATE ALL DRAWINGS AND SPECIFICATIONS PRIOR TO COMMENCING WORK. 16.VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE CONCERNING THE WORK BEFORE PROCEEDING WITH EITHER FABRICATION OR INSTALLATION OF WORK. LOCATION OF EQUIPMENT IS APPROXIMATE. VERIFY THE LOCATION OF ALL SYSTEM COMPONENTS. 17.AVOID ALL CONFLICTS WITH EXISTING LIGHT FIXTURES, HVAC DIFFUSERS, GRILLES, DUCTS, CONDUIT AND OTHER PIPING OR OTHER OBSTRUCTIONS ENCOUNTERED. COORDINATE ALL WORK WITH FIELD CONDITIONS. 18.DO NOT CUT OR PATCH STRUCTURAL WORK IN A MANNER THAT WOULD RESULT IN A REDUCTION OF LOAD-CARRYING OR LOAD-DEFLECTION RATIO. 19.PROVIDE ACCEPTANCE TESTING OF THE FIRE ALARM SYSTEM IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 20."PROVIDE" MEANS CONTRACTOR MUST FURNISH NEW AND INSTALL COMPLETE AND READY FOR INTENDED USE. F FACP S P F H FIRE ALARM HORN/STROBE FIRE ALARM REMOTE ANNUNCIATOR PANELANN FIRE FIGHTER PHONEP SUPERVISED CONTROL VALVE CHECK VALVE PREACTION VALVE UPRIGHT SPRINKLER SPRINKLER PIPE AIR COMPRESSORAC FIRE ALARM 2-HOUR CI CABLE IN CONDUIT EXISTING UPRIGHT SPRINKLER EXISTING SPRINKLER PIPE EXISTING TO REMAINEX HYDROGEN GAS DETECTORH EXISTING ELECTRICAL POWER PANELELECEX G H GAS DETECTION HORN/STROBE, RED STROBE, HIGH/LOW TONE ADDRESSABLE RELEASING CONTROL PANELRCP SOLENOID VALVESV WATERFLOW SWITCHWF TAMPER SWITCHTS LOW AIR SUPERVISORY SWITCHLA ADDRESSABLE OUTPUT MODULE ADDRESSABLE INPUT MODULEAIM AOM ADDRESSABLE RELAYAR END OF LINE RESISTOREOL CONNECT TO EXISTING REMOVE DEVICE AND ASSOCIATED EQUIPMENT TRANSIENT VOLTAGE SURGE SUPPRESSIONTVSS FULL-PORT BALL VALVE VELOMETERV