HomeMy WebLinkAbout003.0_S-101 PENTHOUSE FLOOR PLAN1 2 3 E D C 1 2 3 E D C7' - 6 5/8"7' - 6 5/8"7' - 6 5/8"1 5' - 2 1/4" 5' - 10 3/4" 6' - 7 1/4" 7' - 3 3/4" (E) W12X16 BELOW (E) W12X16 BELOW BEAMS EXTEND 3" PAST GRIDLINE BEAMS EXTEND 3" PAST GRIDLINE 1/2" GAP BETWEEN ENDS OF BEAMS, TYP. ABOVE EXISTING BEAMS (E) W36X150 BELOW (E) W36X150 BELOW (E) W21X50 BELOW(E) W24X55 BELOWCORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 136 HOY ROAD RHODES HALL UPS REPLACEMENT S-101 11874770 PENTHOUSE FLOOR PLAN Q. OLSEN JD 2051 APRIL 8, 2020 SCALE:1/4" = 1'-0"1 NEW FRAMING ABOVE SLAB 0 2 4 8 SCALE: 1/4"=1'-0" GENERAL NOTES 1. EXISTING BATTERY CABINETS CAN REMAIN IN PLACE WHEN STEEL IS INSTALLED. 2. REMOVE TWO EXISTING BATTERY CABINETS PRIOR TO INSTALLATION OF TWO NEW CABINETS. REMOVE REMAINING TWO EXISTING BATTERY CABINETS PRIOR TO INSTALLATION OF FINAL TWO NEW CABINETS. THIS IS CRITICAL FOR THE LOAD OF THE CABINETS TO NOT EXCEED THE CAPACITY OF THE STRUCTURAL FRAMING. WHEN BATTERIES ARE BROUGHT INTO THE ROOM, THEY MUST BE BROUGHT IN WITH ONLY A SINGLE LAYER OF BATTERIES ON THE PALLET. IF THE CONTRACTOR WISHES TO TRANSPORT THE BATTERIES IN A DIFFERENT WAY, THE ENGINEER OF RECORD MUST APPROVE FIRST. 3. SEE ELECTRICAL DRAWINGS FOR THE EXACT LAYOUT OF THE BATTERY CABINETS. THE CABINETS MUST BE CENTERED BETWEEN GRIDS D AND E. THE CABINETS MUST BE CENTERED ON THE NEW STEEL BEAMS IN THE EAST-WEST DIRECTION. 4. SEE ELECTRICAL DRAWINGS FOR CONCRETE EQUIPMENT PADS TO BE REMOVED IN THE 1-2/D-E BAY MUST BE REMOVED PRIOR TO THE INSTALLATION OF THE BATTERY CABINETS. THE CONCRETE PADS IN THE 1-2/C-D BAY MUST BE REMOVED PRIOR THE UPS & SBM INSTALLATIONS. CONTRACTOR TO PROTECT EXISTING STRUCTURAL SLAB DURING DEMO OF CONCRETE EQUIPMENT PADS. 5. CONTRACTOR TO REVIEW SEQUENCE OF DEMO AND INSTALLATION WITH STRUCTURAL ENGINEER PRIOR TO BEGINNING DEMO AND INSTALLATION. THERE ARE LIMITED OPTIONS FOR TEMPORARY SHORING BECAUSE OF THE SERVER ROOM LOCATED DIRECTLY BELOW. SEE THE LIVE LOAD MAP ON S-001 FOR THE MAXIMUM LOADS THAT CAN BE PLACED ON THE FLOOR IN EACH AREA WITHOUT ANY SHORING BEING REQUIRED. THESE LOADS ASSUME THE CONCRETE EQUIPMENT PADS HAVE ALREADY BEEN REMOVED. S-100 KEYED CONSTRUCTION NOTES 1 12 NEW W8 X 31 BEAMS TO BE INSTALLED SO THAT THE BOTTOM OF THE STEEL IS 1 ½” ABOVE THE TOP OF THE SLAB. # 1 08/16/19 ISSUE FOR DD REVIEW 2 03/20/20 ISSUE FOR 95% REVIEW 3 05/05/20 ISSUE FOR COORDINATED REVIEW 4 04/08/20 ISSUE FOR CONSTRUCTION