Loading...
HomeMy WebLinkAboutED161R.2 ELC049MDPB MDPB-4 AC-2 VFD TO EXISTING BUILDING GROUNDING SYSTEM POWER HOUSE 'C' POWER HOUSE 'B' 10 9 8.6 8 7 6 5 E F G H 4.2 4.6 6.7 6.8 G.5 Z.1Y.4 Y.3 Y.2 F.05 Y.1 E.4 5 4 2 3 1 Bengineering, p.c.EC Phone: (585) 641-7121 Fax: (585) 362-4175 www.ec4b.com 15 Schoen Place Suite 300 Pittsford, NY 14534 DESIGN / BUILD CONTRACTOR 760 BROOKS AVE ROCHESTER NY 14619 PHONE 585-224-1111 FAX 585-434-3850billitierelectric.com BILLITIER ELECTRIC N 3 2 4 1 KEY PLAN Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job and this office must be notified of any variation from the dimensions and conditions shown by these drawings. WEGMANS PROJECT #: DRAWN BY:CHECKED BY: FOOD MARKETS, INC. PRICING SET: PERMIT SET: CONST SET: COPYRIGHT © 2019 BY WEGMANS FOOD MARKETS, INC. ALL RIGHTS RESERVED. THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS, INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS, INC. PROJECT #: DS1567 SCALE:Printed from:Drawing File Location:1/16/2020 3:41:44 PMC:\Users\ceverdyke\Documents\Wegmans_071_Ithaca_ELEC_CENTRAL_CD_v2019_ceverdyke@billitierelectric.com.rvt1/8" = 1'-0" ED161R.2 5187 PRICING SET 01/20/2020 MJDCMEITHACA #07101/20/2020 N/A N/A MECHANICAL EQUIPMENT ROOF PLAN - QUADRANT 2 DEMO 500 SOUTH MEADOW STREET, ITHACA, NY 14850INFRASTRUCTURE - HVAC - AC-1 ANDAC-2 REPLACEMENTY:\ ITHACA (S-071)\AsBuilts-Current Drawings SCALE:1/8" = 1'-0"ED161R.2 1 MECHANICAL ROOF EQUIPMENT QUADRANT 2 - DEMO DEMOLITION WORK KEYED NOTES: 1. 2. 3. 4. 5. DISCONNECT AND REMOVE EXISTING ELECTRICAL CONNECTIONS, NETWORK CONNECTIONS, ASSOCIATED MOTOR CONTROLS AND DISCONNECT SWITCHES TO ACCOMMODATE REMOVAL OF AC-1 (BY OTHERS). EXISTING PHASE AND GROUNDING CONDUCTORS AND 2-1/2" CONDUIT TO REMAIN AND BE RE-USED. PROVIDE MODIFICATIONS AS REQUIRED. DISCONNECT AND REMOVE ALL ASSOCIATED ELECTRICAL AND CONTROLS WIRING TO FACILITATE REMOVAL OF UNIT FROM THE ROOF TOP. DISCONNECT AND REMOVE ALL WIRING AND RACEWAYS ASSOCIATED WITH THE VARIABLE FREQUENCY DRIVE (VFD) LOCATED IN AC-2 VESTIBULE. DISCONNECT BUILDING GROUNDING CONDUCTORS FROM UNIT AND RETAIN FOR REUSE. # MECHANICAL CONSTRUCTION GENERAL WORK NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. PROVIDE ACCURATE AS-BUILT DOCUMENTATION AND UPDATE PANELBOARD SCHEDULES AS REQUIRED. ELECTRICAL DEMOLITION DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL INTENT AND SCOPE. EXISTING CIRCUITS MUST BE IDENTIFIED AND THE ENERGY SOURCE ISOLATED MAKING THE EQUIPMENT AND/OR SUPPLY RECEPTACLES INOPERABLE PRIOR TO PERFORMING ANY ELECTRICAL DEMOLITION AS PER BILLITIER ELECTRIC'S LOCK OUT TAG OUT PROGRAM. ONLY PROPERLY TRAINED AUTHORIZED INDIVIDUALS MAY ISOLATE THE POWER SOURCE. EXISTING SPARE CIRCUITS INCLUDING CONDUIT, CONDUCTORS, WIRING DEVICES OR CORD DROPS MAY BE RE-USED IF THEY ARE DEEMED TO BE IN GOOD CONDITION AND OF ADEQUATE SIZE AND QUANTITY FOR A CODE COMPLIANT INSTALLATION. ALL EQUIPMENT AND MATERIAL REMOVED SHALL BE HANDED OVER TO THE CUSTOMER. ALL MATERIAL THAT IS TO BE DISPOSED OF WILL BE DONE SO AT THE CUSTOMER'S REQUEST. CONTINUITY OF "EXISTING TO REMAIN" ELECTRICAL CIRCUITS AND DEVICES SHALL BE MAINTAINED. IDENTIFY CIRCUITING FOR ALL EQUIPMENT THAT IS TO BE REMOVED OR RELOCATED: ·IF REQUIRED BY KEYNOTE, DISCONNECT POWER AND REMOVE CONDUITS AND CONDUCTORS BACK TO SOURCE. COMPLETELY REMOVE ASSOCIATED BOXES, WIRING DEVICES, AND/OR CORD DROPS. BRANCH CIRCUITING SHALL NOT BE ABANDONED IN PLACE. ·IF REQUIRED BY KEYNOTE, DISCONNECT CIRCUITING AND PULL BACK/RELOCATE TO A SAFE LOCATION DURING DEMOLITION AND LABEL WITH SOURCE. REFER TO MECHANICAL ENGINEERING DEMOLITION DRAWINGS REGARDING EXISTING INPUT AND OUTPUT CABLING. DISCONNECT POWER, ASSOCIATED BOXES AND RACEWAY FOR ITEMS TO BE REMOVED. # DATE REVISION 1 01/20/20 PRICING SET 071-5187/ELC049