E001 ELC049
PANEL: MDPB VOLTAGE: 480Y/277 LOCATION: POWERHOUSE 'B' PHASE: 3 FED FROM:MDP2 WIRE: 4 UL LISTED EQUIPMENT SHORT CIRCUIT RATING:35 KAIC MAIN BUS AMPS: 1200A MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT:24,715 MAIN CIRCUIT BREAKER: MAIN LUGS ONLY PHASE CONDUCTOR:(3) #350MCM MOUNTING: SURFACE NEUTRAL CONDUCTOR:(1) #350MCM FEED:BOTTOM ELECTRICAL GROUND CONDUCTOR:(1) #1/0 FEED-THRU LUGS: NONE PHASE AMPS BREAKER BREAKER PHASE AMPS LOAD DESCRIPTION AND LOCATION PH. A PH. B PH. C POLES AMPS CKT. PHASE CKT. AMPS POLES PH. A PH. B PH. C LOAD DESCRIPTION AND LOCATION TRANSFORMER T-4 3 200 1 A 2 200 3 TRANSFORMER T-5B C TRANSFORMER T-7 3 200 3 A 4 250 3 A/C-2B C SPACE 5 A 6 125 3 A/C-3B C TRANSFORMER T-9 3 70 7 A 8 40 3 COMPACTORB C BALER 3 30 9 A 10 30 3 SPAREB C TRANSFORMER T-6 3 300 11 A 12 400 3 PANEL PP3B C SPARE 3 20 13 A 14 20 3 SPAREB C TOTAL AMPS 0 0 0 0 0 0 TOTAL AMPS PH. A PH. B PH. C NOTES: TOTAL PHASE AMPS 0 0 0 * - GFCI TYPE CIRCUIT BREAKER TOTAL PHASE KVA 0.00 0.00 0.00 ** - PROVIDE ADDITIONAL SPARE CIRCUIT BREAKER, SHIP LOOSE TOTAL 3-PHASE KVA 0.00 *** - PROVIDE BREAKER HANDLE LOCK WITH PADLOCKING PROVISION #071 ITHACA Revised:1/8/2020 PANEL: MDPA VOLTAGE: 480Y/277 LOCATION: POWERHOUSE 'A' PHASE: 3 FED FROM:MDP2 WIRE: 4 UL LISTED EQUIPMENT SHORT CIRCUIT RATING:35 KAIC MAIN BUS AMPS: 1200A MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT:24,715 MAIN CIRCUIT BREAKER: MAIN LUGS ONLY PHASE CONDUCTOR:(3) #350MCM MOUNTING: SURFACE NEUTRAL CONDUCTOR:(1) #350MCM FEED:BOTTOM ELECTRICAL GROUND CONDUCTOR:(1) #1/0 FEED-THRU LUGS: NONE PHASE AMPS BREAKER BREAKER PHASE AMPS LOAD DESCRIPTION AND LOCATION PH. A PH. B PH. C POLES AMPS CKT. PHASE CKT. AMPS POLES PH. A PH. B PH. C LOAD DESCRIPTION AND LOCATION TRANSFORMER T-3 3 200 1 A 2 200 3 TRANSFORMER T-1B C AUTOMATIC TRANSFER SWITCH 3 100 3 A 4 SPACEB C AIR DOOR (AD-1)3 40 5 A 6 30 3 BALERB C TRANSFORMER ABOVE CEILING 3 30 7 A 8 30 3 SPAREB C PANEL PP1 3 400 9 A 10 225 3 A/C-1B C PANEL PPPHC1 3 250 11 A 12 300 3 TRANSFOMER T-2B C SPACE 13 A 14 SPACEB C TOTAL AMPS 0 0 0 0 0 0 TOTAL AMPS PH. A PH. B PH. C NOTES: TOTAL PHASE AMPS 0 0 0 * - GFCI TYPE CIRCUIT BREAKER TOTAL PHASE KVA 0.00 0.00 0.00 ** - PROVIDE ADDITIONAL SPARE CIRCUIT BREAKER, SHIP LOOSE TOTAL 3-PHASE KVA 0.00 *** - PROVIDE BREAKER HANDLE LOCK WITH PADLOCKING PROVISION #071 ITHACA Revised:1/8/2020 PUSHBUTTON STATION DOUBLE DUPLEX RECEPTACLE LOW VOLTAGE TRANSFORMER LOCKABLE MANUAL MOTOR SWITCH. FUSIBLE DISCONNECT SWITCH. REFER TO GENERAL NOTE 'C'. SINGLE RECEPTACLE CORD REEL: 120V, 12/3C, 50' W/ BALL STOP (WOODHEAD, MCGILL #92433 W/ BALL STOP, OR APPROVED EQUAL) POWER/TELECOMM POLE: EZ-POLE, KNOCKOUTS AT BOTTOM OF POLE (SEE DETAILS THIS SHEET) GANGED COMBINATION CCTV OUTLET/DUPLEX RECEPTACLE W/ BARRIER. "WP" INDICATES WEATHERPROOF. REFER TO SPECIAL SYSTEMS PLANS. CORD DROP WITH DEVICE & CABLE. TYPE AS NOTED. DUPLEX RECEPTACLE, 120V, STANDARD 18" AFF TO CENTER UNLESS NOTED OTHERWISE. SUBSCRIPTS INDICATE (TYPICAL FOR ALL RECEPTACLE TYPES): 46" - HEIGHT OF RECEPTACLE TO CENTER ABOVE FINISHED FLOOR GFI - INDICATES GROUND FAULT INTERRUPT C - INDICATES CEILING FLUSH MTD TP - TAMPER PROOF WP - INDICATES WEATHERPROOF COVER UPS - INDICATES UPS FEED GEN - INDICATES GENERATOR FEED (RECEPTACLE TO BE LABELED) CAB - INDICATES INSTALLED WITHIN CABINETRY USE - INDICATES WET LOCATION IN-USE COVER SRG - INDICATES SURGE SUPPRESION WITH LIGHT AND ALARM 20A SIMPLEX RECEPTACLE CAB - INSTALLED WITHIN CABINET 15A SIMPLEX RECEPTACLE CAB - INSTALLED WITHIN CABINETRY EQUIPMENT DESIGNATION PLUGMOLD - PRE-WIRED MULTIOUTLET SYSTEM WITH OUTLETS 18" ON CENTER UNLESS OTHERWISE NOTED. HUBBELL SUPER BASE TRAK MULTI - CHANNEL RACEWAY SYSTEM. SPECIAL PURPOSE RECEPTACLE - SEE EQUIPMENT SCHEDULE OR DRAWING NOTE FOR DEVICE CALLOUT CONDUIT HOMERUN TO PANELBOARD (3/4" MINIMUM UNLESS OTHERWISE NOTED) NON-FUSED DISCONECT SWITCH, AUX-INDICATE AUXILARY CONTACT. COMBINATION MOTOR STARTER. EQUIPMENT CONNECTION CORD DROP BUNDLE, COORDINATE EXACT LOCATION WITH OWNER. ALL EQUIPMENT/DEVICES SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. T A. CR A 1 CAB 46" GFI CD ELECTRICAL SYMBOL LIST SYMBOL DESCRIPTION EQUIPMENT IDENTIFIER: 92-CAS0277 DEPARTMENT NUMBERGENERAL NOTES: CAB TV EMERGENCY STOP BUTTONE JUNCTION BOXJ 15A DUPLEX TWIST-LOCK RECEPTACLE. CAB - INSTALLED WITHIN CABINETCAB NETWORK SYMBOL LIST SYMBOL DESCRIPTION DENOTES NETWORK JACK: 8-PIN CAT6, 568B. INSTALLED AT 18" AFF UNLESS NOTED OTHERWISE. QUANTITY AS INDICATED ON DRAWINGS. ELEVATIONS AS INDICATED ON DRAWINGS. REFER TO DRAWING NOTES FOR SPECIAL APPLICATIONS. INSTALL JACKS IN MULTI-PORT FACE PLATE OR SURFACE MOUNT HOUSING WITHIN CABINETRY, FIXTURE, OR ENCLOSURE (REFER TO DETAIL SHEETS PROVIDED BY OWNER FOR LOCATIONS WITHIN CABINETRY). PROVIDE CHASE TO ACCOMMODATE WIRING, AS REQUIRED. UTILIZE THE FOLLOWING AS REQUIRED: • 4-PORT FACEPLATE • SURFACE MOUNT HOUSING • SURFACE MOUNTED DEVICE BOX, AS REQUIRED. CAB JACK FOR HANGING TYPE PHONE ON WALL. MOUNT AT 54" AFF TO CENTERLINE UNLESS OTHERWISE NOTED. FOR HOLLOW WALL AND MASONRY WALL INSTALLATIONS, PROVIDE 1/2" PVC CHASE WITHIN WALLS AS REQUIRED. INSTALL TELEPHONE WALL MOUNT KIT FURNISHED BY OWNER. UTILIZE THE FOLLOWING AS REQUIRED: • SINGLE GANG, SLOPED VERTICAL WALL PLATE. INSTALL PLATE ON 1-1/4"D SURFACE MOUNTED BOX ON MASONRY WALL. W JACK FOR HANGING TYPE PHONE ON STEEL COLUMN. MOUNT AT 54" AFF TO CENTERLINE UNLESS OTHERWISE NOTED. INSTALL IN WEB OF COLUMN WITH SELF TAPPING SCREWS. PROVIDE 1/2" PVC CHASE TO BAR JOIST. UTILIZE THE FOLLOWING AS REQUIRED: • SINGLE GANG, SLOPED VERTICAL WALL PLATE. INSTALL PLATE ON 1-1/4"D SURFACE MOUNTED BOX. COL JACK FOR HANGING TYPE CUSTOMER SERVICE RED PHONE. MOUNT AT 48" AFF TO CENTERLINE UNLESS OTHERWISE NOTED. INSTALL IN WEB OF COLUMN (SEE ABOVE) OR IN HOLLOW WALL, AS SHOWN ON DRAWINGS. PROVIDE 1/2" PVC CHASE TO BAR JOIST OR TO ABOVE ACCESSIBLE CEILING. UTILIZE THE FOLLOWING AS REQUIRED: • 1-PORT WALL MOUNTED JACK AND FACEPLATE. INSTALL ON 1-1/4"D SURFACE MOUNTED BOX (ON COLUMN). CS JACK FOR SCALES IN WASHDOWN OR COOLER AREAS. INSTALL JACKS IN WATER RESISTANT FACEPLATE MOUNTED ON SURFACE MOUNTED PVC BOX. PROVIDE 1/2" PVC CHASE TO ABOVE COOLER CEILING. SEAL BOTH SIDES OF CONDUIT PENETRATIONS. UTILIZE THE FOLLOWING AS REQUIRED: • WATER RESISTANT FACEPLATE. PROVIDE1-GANG PVC SURFACE MOUNTED BOX SNAP IN BLANKS AS REQUIRED. S "WIRELESS ACCESS POINT" (AP) JACK FOR AP ANTENNA LOCATED AT BAR JOIST OR CABLE TRAY. SITE SURVEY REQUIRED PRIOR TO INSTALLATION TO DETERMINE EXACT LOCATIONS AND QUANTITY. PROVIDE 20' OF EXCESS CABLE, NEATLY COILED. UTILIZE THE FOLLOWING AS REQUIRED: • SURFACE MOUNTED HOUSEING AP "ASCOM WIRELESS SYSTEM" (AWS) PROVIDE CAT6 WITH RJ45 JACK AT ANTENNA AND HOMERUN CABLE TO 24-PORT PATCH PANEL LOCATED IN NETWORK RACK 1 IN ROOM 314. PROVIDE 20' OF ADDITIONAL CABLE COILED NEATLY AT THE ANTENNA LOCATION. INSTALL ANTENNAS (FURNISHED BY OWNER) AS DESCRIBED BY EACH ANTENNA'S INDIVIDUAL NOTE. COORDINATE WITH WEGMANS IT PERSONNEL FOR FINAL LOCATION, TERMINATIONS, AND TESTING PROCEDURES. UTILIZE THE FOLLOWING AS REQUIRED: • SURFACE MOUNTED HOUSEING AWS1 NETWORK CONNECTION FOR IP CCTV CAMERA. PROVIDE 15' OF EXCESS CABLE, NEATLY COILED AT JACK. COORDINATE EXACT LOCATION AND ELEVATION OF CAMERA WITH SPECIAL SYSTEMS DRAWINGS PRIOR TO ROUGH-IN. CCTV CELL BOOSTER SYSTEM ANTENNA (BY OTHERS). # - INDICATES CELL BOOSTER SIGNAL ANTENNA NUMBER CT - INDICATES ANTENNA MOUNTED TO UNDERSIDE OF CABLE TRAYCT CELL BOOSTER SYSTEM HEAD END (BY OTHERS). ANT. # NETWORK JACK IDENTIFIER: PORT NUMBER PATCH PANEL # PATCH LOCATION I.D. (ROOM DOOR #) XXX-XX-XX Bengineering, p.c.EC Phone: (585) 641-7121 Fax: (585) 362-4175 www.ec4b.com 15 Schoen Place Suite 300 Pittsford, NY 14534 DESIGN / BUILD CONTRACTOR 760 BROOKS AVE ROCHESTER NY 14619 PHONE 585-224-1111 FAX 585-434-3850billitierelectric.com BILLITIER ELECTRIC N 3 2 4 1 KEY PLAN Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job and this office must be notified of any variation from the dimensions and conditions shown by these drawings. WEGMANS PROJECT #: DRAWN BY:CHECKED BY: FOOD MARKETS, INC. PRICING SET: PERMIT SET: CONST SET: COPYRIGHT © 2019 BY WEGMANS FOOD MARKETS, INC. ALL RIGHTS RESERVED. THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS, INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS, INC. PROJECT #: DS1567 SCALE:Printed from:Drawing File Location:1/16/2020 3:43:18 PMC:\Users\ceverdyke\Documents\Wegmans_071_Ithaca_ELEC_CENTRAL_CD_v2019_ceverdyke@billitierelectric.com.rvt12" = 1'-0" E001 5187 PRICING SET 01/20/2020 MJDCMEITHACA #07101/20/2020 N/A N/A ELECTRICAL SYMBOL LIST AND PANEL SCHEDULES500 SOUTH MEADOW STREET, ITHACA, NY 14850INFRASTRUCTURE - HVAC - AC-1 ANDAC-2 REPLACEMENTY:\ ITHACA (S-071)\AsBuilts-Current Drawings E001 1 POWER EQUIPMENT SYMBOLS LISTPOWER EQUIPMENT SYMBOLS LIST E001 2 NETWORK SYMBOLS LISTNETWORK SYMBOLS LIST E001 3 PANEL SCHEDULESPANEL SCHEDULES # DATE REVISION 1 01/20/20 PRICING SET 071-5187/ELC049