071 A G000 ARC 133
D RA IN ELCC H ASE 2. 5"G AS D RA IN 2. 5"G AS D RA IN ELCC H ASE 1. THE AREA OF WORK FOR THIS PROJECT HAS BEEN DESIGNED TO MEET THE FOLLOWING REQUIREMENTS OF THE: NYS UNIFORM FIRE PREVENTION AND BUILDING CODE WITH 2017 UNIFORM CODE SUPPLEMENTS, AS APPLICABLE INTERNATIONAL EXISTING BUILDING CODE, 2015 (IEBC) INTERNATIONAL BUILDING CODE, 2015 (IBC) ICC A117.1 -2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES INTERNATIONAL FIRE CODE, 2015 (IFC) NYS ENERGY CONSERVATION CONSTRUCTION CODE - INTERNATIONAL ENERGY CONSERVATION CODE -2015 (IECC) WITH 2016 ENERGY CODE SUPPLEMENTS, AS APPLICABLE REFER TO ENGINEERING DRAWINGS FOR THE AREA OF WORK DESIGNED IN COMPLIANCE WITH OTHER APPLICABLE CODE SECTIONS 2. THE ORIGINAL BUILDING CONSTRUCTION WAS COMPLETED IN 1997. 3. CONSTRUCTION CLASSIFICATION TYPE: IIB 4. OCCUPANCY CLASSIFICATION: USE GROUP (M) MERCANTILE, SUPERMARKET 5. ALLOWABLE BUILDING AREA: UNLIMITED (EXISTING FIRE WALL AT RECEIVING) 6. THE BUILDING IS PROVIDED WITH AN AUTOMATIC FIRE PROTECTION SPRINKLER SYSTEM PER NFPA-13, AND SHALL BE MAINTAINED IN THE AREA OF WORK. THE NFPA SPRINKLER SYSTEM IS MONITORED AS REQUIRED BY IBC SECTION 903.4. 7. CLASSIFICATION OF WORK: ALTERATION -LEVEL 2 8. AREA/OCCUPANCY LOADS EXISTING BUILDING 1ST FLOOR AREA: 115,110 S.F. OCCUPANCY: 2,808 PEOPLE MEZZANINE AREA: 7,848 S.F. OCCUPANCY: 208 PEOPLE ALTERATION: ROOF WORK ONLY 9. MAXIMUM TRAVEL DISTANCE ALLOWED: 250' AREA OF WORK-NO CHANGE IN TRAVEL DISTANCE 10. MAXIMUM DEAD END CORRIDOR ALLOWED: 35' AREA OF WORK-NO DEAD END CORRIDORS 11. MINIMUM EXIT CORRIDOR WIDTH REQUIRED: 44" AREA OF WORK-NO CHANGE IN CORRIDOR WIDTH 12. TOTAL BUILDING EGRESS WIDTH REQUIRED: 452" TOTAL BUILDING EGRESS WIDTH ACTUAL: 634" AREA OF WORK-NO CHANGE IN EGRESS WIDTH (UPDATE 8/10/2017) Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job and this office must be notified of any variation from the dimensions and conditions shown by these drawings. WEGMANS PROJECT #: DRAWN BY:CHECKED BY: FOOD MARKETS, INC. PRICING SET: PERMIT SET: CONST SET: COPYRIGHT © 2019 BY WEGMANS FOOD MARKETS, INC. ALL RIGHTS RESERVED. THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS, INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS, INC. PROJECT # 014339.12 SCALE:Printedfrom:DrawingFileLocation:AS NOTED UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING ISA VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209 1/24/20209:18:16AMC:\RevitProjects\Wegmans_0715187_Ithaca_ARCH_CD_Central_v2019_bthompson.rvtG000 071-5187 PRICING SET 01/20/2020 MJSBJTITHACA#07101/20/20 COVER PAGE500S.MEADOWSTREET,ITHACA,NY14850INFRASTRUCTURE-HVAC-AC-1ANDAC-2REPLACEMENTMICHAEL J. SORENSEN LICENSE #: 033368 Y:\ITHACA(S-071)\AsBuilts-CurrentDrawingsProject #: Status: Issue Date: Store #: INFRASTRUCTURE -HVAC -AC-1 AND AC-2 REPLACEMENT PRICING SET 500 S. MEADOW STREET, ITHACA, NY 14850 071-5187 01/20/2020 071 DRAWING LIST G000 COVER PAGE AD151 DEMOLITION ROOF PLAN OVERALL A151 ROOF PLAN OVERALL KEY PLAN AREAS OF WORK #DATE REVISION 1 01/20/20 PR# 071-5187 2 01/20/20 RB# 071-ARC-133 PRICING SET