Loading...
HomeMy WebLinkAboutOlin Chemical LabPAVED PARKING PAVED PARKING UNPAVED PARKING UNPAVED PARKING SS S FP SIGN CB CB CB CB CB CB CB CB CBCB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB 191920202021212121202020201919 191920202021212121202020201919 191920202021212121202020201919 191920202021212121202020201919 191920202021212121202020201919 19 19 21 20202020 21 21212121212121 212121 21212121 UP UP DNUP UP DN UPDN OLIN HALL 2024 CAMPUS ROAD COLLEGE AVE.HOY ROADCORNE LL U N I V E R SI TYFOUN D E D 5681 AD CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 Cornell University OLIN HALL OLIN HALL ROOM 204 LAB RENOVATION T-001 11982592 TITLE SHEET FE DESIGN JD 2024 DECEMBER 16, 2019 OLIN HALL ROOM 204 LAB RENOVATION GENERAL T-001 TITLE SHEET ARCHITECTURAL A-000 CODE COMPLIANCE PLAN, GENERAL NOTES A-101 DEMOLITION AND RENOVATION PLAN A-601 EQUIPMENT MATRIX MECHANICAL M-001 GENERAL NOTES AND SYMBOL LEGENDS M-101 ROOM 204 DEMOLITION AND NEW WORK ELECTRICAL E-001 GENERAL NOTES AND SYMBOL LEGENDS E-101 RENOVATION PLANS SITE LOCATION -OLIN HALL KEY PLAN -SECOND FLOOR AREA OF WORK BUILDING CODE SUMMARY APPLICABLE CODES 2015 INTERNATIONAL BUILDING CODE* 2015 INTERNATIONAL EXISTING BUILDING CODE* 2015 INTERNATIONAL FIRE CODE* 2015 INTERNATIONAL PLUMBING CODE* 2015 INTERNATIONAL MECHANICAL CODE* 2015 INTERNATIONAL ENERGY CONSERVATION CODE* * INCLUDING 2016 AND 2017 NYS UNIFORM CODE SUPPLEMENTS 2009 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2010 AMERICANS WITH DISABILITY ACT (ADA) PROJECT SUMMARY THIS PROJECT INCLUDES THE RENOVATION OF 384 SF OF LAB SPACE. THE WORK IS ALTERATION LEVEL 2. ALTERATION LEVEL 2: LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENTION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. AN EXISTING BUILDING OR PORTION THEREOF SHALL NOT BE ALTERED SUCH THAT THE BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITIONS. BUILDING LIMITATIONS CONSTRUCTION CLASSIFICATION:1A CLASSIFICATION OF HAZARDS:NONE HIGH-RISE BUILDING: NO EXTINGUISHING REQUIREMENT:THE EXISTING BUILDING IS SPRINKLERED OCCUPANCY OCCUPANCY CLASSIFICATION:BUSINESS (B) AREA OF WORK DRAWING INDEX PROJECT SCOPE THE PURPOSE OF THIS PROJECT IS TO PROVIDE FOR THE FIT-OUT OF ROOM 204 WITH RESEARCHER-FURNISHED LAB EQUIPMENT. PERSPECTIVE VIEW GENERAL SYMBOLS LEGEND EXTERIOR ELEVATION 1 1 1 1X-100 X-100 1 1 1 1 INTERIOR ELEVATION 1 X-100 SECTION MARKER 1 X-100 ENLARGED DETAIL #CONSTRUCTION KEYED NOTE DEMOLITION KEYED NOTE# DRAWING REVISION NOTE# LINETYPE: TO BE PROVIDED / NEW LINETYPE: DEMOLITION / TO BE RELOCATED LINETYPE: EXISTING TO REMAIN 1 9/30/2019 ISSUE FOR PROGRESS SET REVIEW 2 10/25/2019 ISSUE FOR 50% CD REVIEW 3 11/26/2019 ISSUE FOR 95% CD REVIEW 4 12/03/2019 ISSUE FOR COORDINATED REVIEW 5 12/16/2019 ISSUE FOR CONSTRUCTION 200UR 111 31 178 361 373 49538554 378 555559 397382 535 300 522 153 245 840 507 251 516 505 291 249 319 320 318 318 317 320 320 155 252340 524 830 523 370 129 211 300 125 241 555 713 20 14 14 19 16 16 27 5498 7294 1120 26 26 107107 75 28 28 2932 1910 1342 367 165 263 200CC 200SC 200EA 201A 201B 201 202 203205 206 208 207209 210212 211 215 214 216218 222 230 228 224 232 244 246 248 250 252 254 256 258 260260A 274 270 276 278 278A 275A275 275B 265C 265B 265 267 255 255B 200SB 200EB 200TA 200UC 200JC 200JB 200TB 226 245 200JA 200UA 200UB 200SA 265A 200CA 200CB 255A 200SD 200SE 230A 230B UP UP DNUP UP DN UPDN 206A 95 101 A101 1 1 1 1 0 Name Elevation 101 X-X X 1t DN WALL -EXISTING WALL -METAL STUD/ GWB WALL -CONCRETE WALL -CMU WALL -BRICK ITEMS FOR DEMOLITION DOOR/ WALL -EXISTING DOOR/ WALL -NEW DOOR/ WALL -DEMOLITION TAG -DOOR TAG -WINDOW TAG -WALL TAG -ROOM # CENTER LINE PHOTO REFERENCE LEVEL MARKER COLUMN GRID MARKER ELEVATION MARKER UP ELEVATION CHANGE ARROWS BREAK LINE SYMBOLS 0' -0" 1-HOUR FIRE SEPARATION 2-HOUR FIRE SEPARATION ABBREVIATIONS A &AND @ AT ACT ACOUSTICAL CEILING TILE ALT ALTERNATE ALUM ALUMINUM AVG AVERAGE AFF ABOVE FINISH FLOOR B BD BOARD BLDG BUILDING BOD BOTTOM OF DECK BSMT BASEMENT C CG CORNER GUARDS CJ CONTROL JOINT CLG CEILING CL CENTER LINE CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONF CONFERENCE CONT CONTINUOUS CORR CORRIDOR CPT CARPET CRS COURSE(S) CT CERAMIC TILE D DEMO DEMOLITION DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DO DOOR OPENING DWG DRAWING E EA EACH EJ EXPANSION JOINT ELEC ELECTRIC ELEV ELEVATION/ ELEVATOR EPDM RUBBER ROOF MEMBRANE EQ EQUAL EX'G EXISTING EXT EXTERIOR F FD FLOOR DRAIN FDN FOUNDATION FEC FIRE EXTINGUISHER CABINET FFE FINISH FLOOR ELEVATION FRP FIBER REINFORCED POLYESTER FT FOOT/FEET FTG FOOTING G GA GAGE GALV GALVANIZED GC GENERAL CONTRACTOR GEN GENERAL GL GLASS GWB GYPSUM WALL BOARD H HC HANDICAPPED HT HEIGHT HM HOLLOW METAL HR HOUR HVAC HEATING, VENTILATING & AC J JAN JANITOR L LAV LAVATORY LB/#POUND LGMF LIGHT GAGE METAL FRAMING M MFR MANUFACTURER MAT MATERIAL MAX MAXIMUM MEZZ MEZZANINE MIN MINIMUM MO MASONRY OPENING MTL METAL N NA NOT APPLICABLE NIC NOT IN CONTRACT NR NOT RATED NTS NOT TO SCALE O OC ON CENTER OD OUTSIDE DIAMETER OPNG OPENING OSB ORIENTER STRAND BOARD P +/-PLUS OR MINUS PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED PI PRINCIPAL INVESTIGATOR Q QTY QUANTITY R R RISER RD ROOF DRAIN REF REFRIGERATOR REQ REQUIRED REV REVISION RO ROUGH OPENING RTU ROOF TOP UNIT S SHTG SHEATHING SIM SIMILAR SF SQUARE FOOT/ FEET SS STAINLESS STEEL STL STEEL STD STANDARD T T TREAD T&G TONGUE & GROOVE TEL TELEPHONE TEMP TEMPERATURE TOS TOP OF STEEL TV TELEVISION TYP TYPICAL U UEV UNEVEN DOORS W/ VISION PANEL UEF UNEVEN FLUSH DOOR V VCT VINYL COMPOSITION TILE VIF VERIFY IN FIELD W W/O WITHOUT WD WOOD AREA OF WORK 66' TRAVEL DISTANCE TO EXIT (IBC 1017.2: MAX 300' WITH SPRINKLER SYSTEM)CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 OLIN HALL OLIN HALL ROOM 204 LAB RENOVATION A-000 11982592 CODE COMPLIANCE PLAN, GENERAL NOTES N.HACHMANN NH 2024 DECEMBER 16, 2019 SCOPE OF WORK 1.0 REMOVE AND/OR MODIFY EXISTING CASEWORK TO CREATE SPACE FOR NEW EQUIPMENT. PATCH SURFACES AS NEEDED TO MATCH ADJACENT SURFACES. GENERAL NOTES 1.0 DESIGN, CONSTRUCTION AND SAFETY SHALL CONFORM TO ALL LOCAL, STATE AND OWNER SPECIFIC CODES, INCLUDING (BUT NOT LIMITED TO) THE NEW YORK STATE UNIFORM FIRE PROTECTION AND BUILDING CODE, LATEST REVISION, THE NFPA 101 LIFE SAFETY CODE, LATEST REVISION, ANSI A117.1 - LATEST REVISION, OSHA, AND ANY OTHER CODES GOVERNED BY THE JURISDICTION IN WHICH THIS PROJECT IS BEING CONSTRUCTED. 2.0 THIS CONTRACT REQUIRES COMPLETE, FINISHED WORKABLE PROJECT OF THE AREAS INDICATED BY THE CONTRACT DOCUMENTS, AND SHALL INCLUDE ALL MATERIALS AND LABOR NECESSARY TO COMPLETE, REGARDLESS OF WHETHER OR NOT ALL WORK OR EACH ITEM IS SPECIFICALLY INDICATED ON ANY OTHER PORTION OF THE DRAWINGS AND / OR NOTES. 3.0 WHERE MATERIALS REFERENCED ON DRAWINGS, OR NECESSARY TO COMPLETE THE WORK OF THIS CONTRACT ARE NOT SPECIFIED HEREIN, PROVIDE BEST QUALITY MATERIALS. WHERE MATERIALS ARE INTENDED TO MATCH EXISTING, PROVIDE CLOSEST POSSIBLE MATCH, SUBJECT TO OWNER'S APPROVAL. ALL ITEMS AND WORK ON DRAWINGS ARE NEW, UNLESS INDICATED EXISTING. ALL WORK WHICH HAS BEEN DAMAGED SHALL BE REPAIRED OR REPLACED AT NO COST TO THE OWNER. WHERE ITEMS CAN NOT BE REPAIRED TO A ""NEW CONDITION"", OR WHERE THE STRUCTURAL INTEGRITY HAS BEEN AFFECTED, ITEMS SHALL BE REPLACED AT NO COST TO THE OWNER. 4.0 CONTRACTOR IS RESPONSIBLE TO VERIFY ALL SITE, FIELD AND BUILDING CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. IF THERE ARE ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS, NOTIFY THE PROJECT MANAGER, WHO WILL REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER AND PROVIDE CLARIFICATION IN WRITING. 5.0 WHERE EXISTING CONSTRUCTION OR ITEMS HAVE BEEN INFILLED, REMOVED AND / OR DISTURBED FOR INSTALLATION OF NEW WORK, CAUSING THE EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES RESULTING SURFACES AND INFILLED SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. ALL ABANDONED OPENINGS (i.e. DUCT/PIPE REMOVALS, ETC.) AT WALLS, ROOF OR FLOOR TO BE INFILLED SOLID. 6.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE WORK OF OTHER TRADES (i.e. ELECTRICAL, MECHANICAL). ALTHOUGH NOT NECESSARILY SHOWN ON DRAWINGS, WORK IS REQUIRED IN THESE AREAS CONSISTING OF REMOVAL / REPLACEMENT OF CEILINGS, WALLS, FINISHES, PAVEMENT AND OTHER CONSTRUCTION AS NECESSARY TO PERFORM WORK AND RESTORE THESE SPACES OR AREAS TO ORIGINAL CONDITION. 7.0 GENERAL CONTRACTOR IS TO COORDINATE WORK OF ALL TRADES. SCHEDULE WORK PROGRESS THROUGHOUT THE ENTIRE PROJECT TO PREVENT CONFLICTS AND INTERFERENCES. OBTAIN ALL NECESSARY INFORMATION SUCH AS SIZES, LOCATIONS, TEMPLATES, LAYOUT, DIMENSIONS AND ALL OTHER INFORMATION NECESSARY FOR A PROPER AND WELL COORDINATED INSTALLATION. PRIOR TO INSTALLATION OF ITEMS, VERIFY AND CONFIRM WITH EACH CONTRACTOR EXACT LOCATION OF ALL ITEMS. 8.0 ALL PENETRATIONS (EXISTING OR NEW) THROUGH FLOORS AND FULL HEIGHT WALLS - IN AREA OF WORK TO BE FIRE STOPPED. ALL GAPS AND JOINTS AT RATED FLOORS, ROOFS AND WALLS TO BE FIRE & SMOKE STOPPED. GAPS AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND CONTROL OR EXPANSION JOINTS. FIRE STOPPING INCLUDES BOTH FORM OR PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. PROVIDE AND INSTALL LABELING REQUIRED BY CODE. LABELS SHALL INCLUDE PENETRATION TYPE WITH UL LISTING USED, MATERIAL USED, DATE INSTALL AND NAME OF INSTALLER. 9.0 JOBSITE WILL BE CLEANED DAILY AND DEBRIS REMOVED TO CONTAINERS OR TO VEHICLE WHICH WILL REMOVE DEBRIS FROM CAMPUS. CONTAINERS WILL BE REMOVED AS SOON AS FULL OR WHEN THE PROJECT HAS PROGRESSED TO A POINT THAT A CONTAINER IS NO LONGER REQUIRED. 10.0 CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL AREAS USED TO BRING SUPPLIES AND EQUIPMENT INTO THE PROJECT AREA. ANY DAMAGE TO AREAS OUTSIDE THE PROJECT AREA INCLUDING BUT NOT LIMITED TO THE LOBBY AND CORRIDOR SHALL BE REPAIRED AT NO COST TO THE OWNER. SCALE: 1/16" = 1'-0" 1 CODE COMPLIANCE PLAN - SECOND FLOOR BUILDING CODE SUMMARY APPLICABLE CODES 2015 INTERNATIONAL BUILDING CODE* 2015 INTERNATIONAL EXISTING BUILDING CODE* 2015 INTERNATIONAL FIRE CODE* 2015 INTERNATIONAL PLUMBING CODE* 2015 INTERNATIONAL MECHANICAL CODE* 2015 INTERNATIONAL ENERGY CONSERVATION CODE* * INCLUDING 2016 AND 2017 NYS UNIFORM CODE SUPPLEMENTS 2009 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2010 AMERICANS WITH DISABILITY ACT (ADA) PROJECT SUMMARY THIS PROJECT INCLUDES THE RENOVATION OF 384 SF OF LAB SPACE. THE WORK IS ALTERATION LEVEL 2. ALTERATION LEVEL 2: LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENTION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. AN EXISTING BUILDING OR PORTION THEREOF SHALL NOT BE ALTERED SUCH THAT THE BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITIONS. BUILDING LIMITATIONS CONSTRUCTION CLASSIFICATION:1A CLASSIFICATION OF HAZARDS:SEE MAQ HIGH-RISE BUILDING:NO EXTINGUISHING REQUIREMENT:THE EXISTING BUILDING IS SPRINKLERED OCCUPANCY OCCUPANCY CLASSIFICATION:BUSINESS (B) 1 10/25/2019 ISSUED FOR 50% CD REVIEW 2 11/26/2019 ISSUED FOR 95% CD REVIEW 3 12/03/2019 ISSUED FOR COORDINATED REVIEW 4 12/16/2019 ISSUED FOR CONSTRUCTION 1 2 3 4 65 22 3 3 65 204 32 4 5 6 7 3' - 5"E8aE8aE7aE7a E9aE9a E4aE4a E5aE5a E3aE3a E6aE6a E11aE11a E10aE10a E1aE1a E2aE2a 8 5' - 0"4' - 6"3' - 6".9 E1c 1 1 CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 OLIN HALL OLIN HALL ROOM 204 LAB RENOVATION A-101 11982592 DEMOLITION AND RENOVATION PLAN N.HACHMANN NH 2024 DECEMBER 16, 2019 A-101 RENOVATION KEY NOTES 1 REINSTALL SUSPENDED CEILING SYSTEM AFTER THE COMPLETION OF MECHANICAL, ELECTRICAL, AND PLUMBING WORK. REPLACE ANY DAMAGED PIECES WITH NEW ACOUSTICAL CEILING PANELS AND GRID TO MATCH EXISTING. 2 AFTER REMOVAL OF WALL MOUNTED ITEMS, PATCH WALL AND TOUCH UP PAINT TO MATCH ADJACENT. 3 PAINT MISCELLANEOUS PIPING AND CONDUIT TO MATCH WALL COLOR. 4 COORDINATE WITH MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION DRAWINGS. 5 EXISTING CASEWORK AND FUME HOOD TO REMAIN UNLESS NOTED OTHERWISE. 6 SEE MECHANICAL PLAN FOR EQUIPMENT INFORMATION. 7 FIRESTOP ANY WALL PENETRATIONS TO ADJACENT ROOMS AND CORRIDOR TO MAINTAIN ONE-HOUR FIRE RATING. 8 TABLE PROVIDED BY LAB OWNER. 9 PROVIDE METAL END PANEL TO MATCH EXISTING CABINETRY FINISH. # A-101 DEMOLITION KEY NOTES 1 HAZARDOUS MATERIALS ARE NOT EXPECTED. ALERT OWNER IF ENCOUNTERING SUSPICIOUS MATERIAL. OWNER WILL PERFORM REMOVAL OF ASBESTOS AND PCB CONTAINING MATERIAL. 2 MODIFY EXISTING CABINETRY TO REMOVE COMPONENTS WHERE NOTED. AT EXISTING SINK LOCATION, CUT COUNTERTOP AND FINISH EDGE TO MATCH EXISTING. COORDINATE WITH MEPFP DRAWINGS. 3 REMOVE EXISTING LOOSE EQUIPMENT AND FURNITURE AND TURN OVER TO OWNER. 4 CAREFULLY REMOVE WALL MOUNTED ITEMS AND SALVAGE FOR REINSTALLATION AS DIRECTED BY OWNER. 5 CAREFULLY REMOVE THE PORTION OF THE EXISTING SUSPENDED CEILING SYSTEM AS REQUIRED TO PERFORM MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION WORK. SALVAGE FOR REINSTALLATION AFTER COMPLETION OF MEPFP WORK. 6 SEE MEPFP DRAWINGS FOR REMOVAL OF MEPFP EQUIPMENT AND COORDINATE ACCORDINGLY. # 0' 2' 4' 8' SCALE: 1/4"=1'-0" SCALE: 1/4" = 1'-0" 1 DEMOLITION PLAN - ROOM 204 SCALE: 1/4" = 1'-0" 2 RENOVATION PLAN - ROOM 204 SCALE: 1/4" = 1'-0" 3 REFLECTED CEILING PLAN - ROOM 204 SCALE:5 3D - ROOM 204 FROM NORTHWEST SCALE:4 3D - ROOM 204 FROM SOUTHEAST LABORATORY EQUIPMENT LIST TAG ROOM FURNISHED BY RIGGED AND MOUNTED BY DESCRIPTION BASIS OF DESIGN LOCATION DIMENSIONS WEIGHT (LBS) CONTRACTOR PROVIDED SERVICES MANUFACTURER MODEL WIDTH (IN) DEPTH (IN) HEIGHT (IN) E1a 204 OWNER OWNER LIQUID CHROMATOGRAPH MASS SPECTROMETER AGILENT G6545 UHD ACCURATE-MASS BENCH 48.0 30.0 76.0 400 EXHAUST DUCTWORK, POWER (SERVED BY E11 UPS) E1b 204 OWNER OWNER COMPUTER - - BENCH - - - - SERVED BY E11 UPS E1c 204 OWNER OWNER BENCH - - FLOOR 84.0 36.0 25.0 - - E2a 204 OWNER OWNER NITROGEN GENERATOR PARKER NITROFLOW FLOOR 12.2 35.4 27.6 204 SERVED BY E11 UPS E3a 204 OWNER OWNER -86°C FREEZER EPPENDORF PREMIUM U410 FLOOR 31.5 33.5 76.0 617 SERVED BY E11 UPS E4a 204 OWNER OWNER EXISTING TO BE RELOCATED - UNDER COUNTER -20°C FREEZER - - FLOOR - - - - - E5a 204 OWNER OWNER EXISTING TO BE RELOCATED - UNDER COUNTER 4°C REFRIGERATOR - - FLOOR - - - - - E6a 204 OWNER OWNER POWERPAC POWER SUPPLY BIO-RAD POWERPAC BASIC BENCH 8.3 9.6 2.6 2.4 - E7a 204 OWNER OWNER INCUBATOR SHAKER EPPENDORF INNOVA 42R BENCH 22 29.7 32.8 267 - E8a 204 OWNER OWNER INCUBATOR THERMOFISHER 3110 BENCH 21.3 25.0 39.5 400 - E9a 204 OWNER OWNER CENTRIFUGE EPPENDORF 5910 R BENCH 28.4 26.0 14.6 240 - E10a 204 OWNER OWNER MILLI Q WATER PURIFICATION SYSTEM EMD MILLIPORE BENCH 13.0 19.0 19.7 62 PLUGS INTO EXISTING RECEPTACLE E11a 204 OWNER OWNER UNINTERRUPTIBLE POWER SUPPLY AMETEK POWERVAR 42060-113R FLOOR 9.8 28.3 32.5 266 - SUBMITTAL REGISTRY SPECIFICATION SECTION TITLE CATEGORY 099123 INTERIOR PAINTING PRODUCT DATA 1 10/25/2019 ISSUED FOR 50% CD REVIEW 2 11/26/2019 ISSUED FOR 95% CD REVIEW 3 12/03/2019 ISSUED FOR COORDINATED REVIEW 4 12/16/2019 ISSUED FOR CONSTRUCTION CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 OLIN HALL OLIN HALL ROOM 204 LAB RENOVATION A-601 11982592 EQUIPMENT MATRIX N.HACHMANN NH 2024 DECEMBER 16, 2019 LABORATORY EQUIPMENT MATRIX TAG ROOM STATUS FURNISHED BY RIGGED AND MOUNTED BY INSTALLATION INSTRUCTIONS/ CHECKLIST DESCRIPTION BASIS OF DESIGN LOCATION DIMENSIONS WEIGHT (LBS) ELECTRICAL HOUSE LABORATORY PLUMBING SYSTEMS CYLINDER GASES OPERATING ENVIRONMENT REQUIREMENTS HEAT GENERATION (BTUH) EXHAUST CFM CONTRACTOR PROVIDED SERVICES MANUFACTURER MODEL WIDTH (IN) DEPTH (IN) HEIGHT (IN)VOLT PH H Z RATING (KW, W, VA, A, HP) RECEPTACLE NEMA RATING GROUND EMERGENCY POWER DCW DHW LAB DRAIN LAB VENT RODI GAS PROP ANE VAC CA (85 PSI)CA LP TEMP °F HUMIDITY % VIBRATION SENSITIVE E1a 204 - OWNER OWNER YES LIQUID CHROMATOGRAPH MASS SPECTROMETER AGILENT G6545 UHD ACCURATE-MASS BENCH 48.0 30.0 76.0 400 208 1 60 2850 W 6-15R - YES - - - - - - - - - YES (NOTE 1)YES 9,640 25 EXHAUST DUCTWORK, POWER (SERVED BY E11 UPS) E1b 204 - OWNER OWNER N/A COMPUTER - - BENCH - - - - 120 1 60 - - - YES - - - - - - - - - - - - NO 325 0 SERVED BY E11 UPS E1c 204 - OWNER OWNER N/A BENCH - - FLOOR 84.0 36.0 25.0 - - - - - - -N/A - - - - - - - - - - - - NO - 0 - E2a 204 - OWNER OWNER YES NITROGEN GENERATOR PARKER NITROFLOW FLOOR 12.2 35.4 27.6 204 110 1 60 1265 W 5-20R - YES - - - - - - - -- - 41- 104°F 80% @ 87.8°F NO 5,756 0 SERVED BY E11 UPS E3a 204 - OWNER OWNER YES -86°C FREEZER EPPENDORF PREMIUM U410 FLOOR 31.5 33.5 76.0 617 208 1 60 8 A 6-15R - YES - - - - - - - - - -NO 2220 0 SERVED BY E11 UPS E3b 204 - CONTRACTOR CONTRACTOR N/A ELECTRICAL CABLE/CORD REFER TO ELEC DWGS REFER TO ELEC DWGS WALL - - - - 208 1 60 - 6-15R - YES - - - - - - - - - - - - NO - 0 POWER, SERVED BY E11 UPS REFER TO ELECTRICAL DRAWINGS E4a 204 EXISTING OWNER OWNER NO EXISTING TO BE RELOCATED - UNDER COUNTER -20°C FREEZER - - FLOOR - - - - 120 1 60 2.2 A 5-20R - NO - - - - - - - - - - NO 871 0 - E4b 204 - CONTRACTOR CONTRACTOR N/A RECEPTACLE REFER TO ELEC DWGS REFER TO ELEC DWGS WALL - - - - 120 1 60 - 5-20R - NO - - - - - - - - - - - - NO - 0 POWER, REFER TO ELECTRICAL DRAWINGS E5a 204 EXISTING OWNER OWNER NO EXISTING TO BE RELOCATED - UNDER COUNTER 4°C REFRIGERATOR - - FLOOR - - - - 120 1 60 2.2 A 5-20R - NO - - - - - - - - - - NO 871 0 - E5b 204 - CONTRACTOR CONTRACTOR N/A RECEPTACLE REFER TO ELEC DWGS REFER TO ELEC DWGS WALL - - - - 120 1 60 - 5-20R - NO - - - - - - - - - - - - NO - 0 POWER, REFER TO ELECTRICAL DRAWINGS E6a 204 - OWNER OWNER YES POWERPAC POWER SUPPLY BIO-RAD POW ERPAC BASIC BENCH 8.3 9.6 2.6 2.4 120 1 60 75 W 5-20R - YES - - - -- - - - - - NO - 0 - E6b 204 - CONTRACTOR CONTRACTOR N/A RECEPTACLE REFER TO ELEC DWGS REFER TO ELEC DWGS WALL - - - - 120 1 60 - 5-20R - YES - - - - - - - - - - - - NO - 0 POWER, REFER TO ELECTRICAL DRAWINGS E7a 204 - OWNER OWNER YES INCUBATOR SHAKER EPPENDORF INNOVA 42R BENCH 22 29.7 32.8 267 120 1 60 1800 W 5-20R - NO - - - - - - - - -- NO 344 0 - E7b 204 - CONTRACTOR CONTRACTOR N/A RECEPTACLE REFER TO ELEC DWGS REFER TO ELEC DWGS WALL - - - - 120 1 60 - 5-20R - NO - - - - - - - - - - - - NO - 0 POWER, REFER TO ELECTRICAL DRAWINGS E8a 204 - OWNER OWNER YES INCUBATOR THERMOFISHER 3110 BENCH 21.3 25.0 39.5 400 115 1 60 432 W 5-20R - NO - - - - - - - - - - NO 344 0 - E8b 204 - CONTRACTOR CONTRACTOR N/A RECEPTACLE REFER TO ELEC DWGS REFER TO ELEC DWGS WALL - - - - 120 1 60 - 5-20R - NO - - - - - - - - - - - - NO - 0 POWER, REFER TO ELECTRICAL DRAWINGS E9a 204 - OWNER OWNER YES CENTRIFUGE EPPENDORF 5910 R BENCH 28.4 26.0 14.6 240 120 1 60 1650 W 5-20R - NO - - - - - - - - - - NO - 0 - E9b 204 - CONTRACTOR CONTRACTOR N/A RECEPTACLE REFER TO ELEC DWGS REFER TO ELEC DWGS WALL - - - - 120 1 60 - 5-20R - NO - - - - - - - - - - - - NO - 0 POWER, REFER TO ELECTRICAL DRAWINGS E10a 204 - OWNER OWNER NO MILLI Q WATER PURIFICATION SYSTEM EMD MILLIPORE BENCH 13.0 19.0 19.7 62 115 1 60 - 5-20R GFCI - NO - - - - - - - - - - NO - 0 PLUGS INTO EXISTING RECEPTACLE E10b 204 EXISTING - - N/A EXISTING RECEPTACLE REFER TO ELEC DWGS REFER TO ELEC DWGS WALL - - - - 120 1 60 - 5-20R GFCI - NO - - - - - - - - - - - - NO - 0 - E11a 204 - OWNER OWNER NO UNINTERRUPTIBLE POWER SUPPLY AMETEK POWERVAR 42060-113R FLOOR 9.8 28.3 32.5 266 208 1 60 6000 VA 6-50R - YES - - - - - - - - - - NO 2,530 0 - E11b 204 - CONTRACTOR CONTRACTOR N/A ELECTRICAL CABLE/CORD REFER TO ELEC DWGS REFER TO ELEC DWGS CABLE - - - - 208 1 60 - 6-50R - YES - - - - - - - - - - - - NO - 0 POWER, REFER TO ELECTRICAL DRAWINGS 1 12/16/2019 ISSUED FOR CONSTRUCTION NOTES: 1) CYLINDER GAS, IN SMALL QUANTITY, PROVIDED BY LAB OWNER 2) ITEMS 3b, 4b, 5b, 6b, 7b, 8b, 9b, 10b, & 11b HAVE BEEN INCLUDED ON THIS MATRIX BUT ARE NOT TAGGED ON THE ELECTRICAL DRAWINGS. CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 OLIN HALL OLIN HALL ROOM 204 LAB RENOVATION M-001 11982592 GENERAL NOTES AND SYMBOL LEGENDS P. OCKENFELS PCO 2024 DECEMBER 16, 2019 MECHANICAL ABBREVIATIONS BCU BLOWER COIL UNIT CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY CC CLEAN CONDENSATE CO CLEAN OUT CS CLEAN STEAM CD CONDENSATE DRAIN EA EXHAUST AIR EAG EXHAUST AIR GRILLE FD FIRE DAMPER GWR GLYCOL HEATING RETURN GWS GLYCOL HEATING SUPPLY HPR HIGH PRESSURE STEAM RETURN HPS HIGH PRESSURE STEAM SUPPLY HWR HOT WATER HEATING RETURN HWS HOT WATER HEATING SUPPLY LPC LOW PRESSURE CONDENSATE LPS LOW PRESSURE STEAM MU MAKE UP WATER MPC MEDIUM PRESSURE CONDENSATE MPS MEDIUM PRESSURE STEAM NG NATURAL GAS PCWR PROCESS CHILLED WATER RETURN PCWS PROCESS CHILLED WATER SUPPLY HG REFRIGERANT HOT GAS RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION RAG RETURN AIR GRILLE SA SUPPLY AIR SAD SUPPLY AIR DIFFUSER VD VOLUME DAMPER MECHANICAL SYMBOLOGY AIRFLOW BACKFLOW PREVENTER BALANCE VALVE BALL VALVE BOTTOM PIPE CONNECTION BUTTERFLY VALVE CAP OR PLUG CHECK VALVE CIRCULATING PUMP DIRECTION OF FLOW DUCT AIRFLOW DUCT DOWN (EXHAUST OR RETURN) DUCT DOWN (SUPPLY) FIRE AND SMOKE DAMPER IN DUCT FIRE DAMPER IN DUCT FLANGE CONNECTION FLEX CONNECTOR FLEXIBLE CONNECTION FLEXIBLE DUCT FLOW METER FLOW SWITCH FUSIBLE LINK VALVE GLOBE VALVE MANUAL AIRVENT ORIFICE METER PIPE DOWN PIPE UP PIPING REDUCER (CONCENTRIC) PIPING REDUCER (ECCENTRIC) PRESSURE GAUGE PRESSURE OR TEMPERATURE PETES PLUG PRESSURE REDUCING VALVE PRESSURE SWITCH RECTANGULAR ELBOW RECTANGULAR ELBOW WITH TURNING VANES RELIEF VALVE SMOKE DAMPER IN DUCT SOLENOID VALVE STANDARD BRANCH DUCT STEAM TRAP STRAINER (DUPLEX) STRAINER WITH BLOWDOWN VALVE AND CAP SUPPLY THROUGH NEXT FLOOR OR ROOF TEMPERATURE WELL THERMOMETER THERMOMETER (DIAL) TOP PIPE CONNECTION TRIPLE DUTY VALVE UNION CONNECTION VACUUM BREAKER VOLUME DAMPER IN DUCT GENERAL DRAWING SYMBOLOGY DEMOLISHED WORK EXISTING PIPING TO REMAIN EXISTING TO REMAIN EXISTING WORK TO REMAIN NEW WORK POINT OF CONNECTION POINT OF DISCONNECTION CONTROL ABBREVIATIONS AI ANALOG INPUT AO ANALOG OUTPUT AV ANALOG VALUE BI BINARY INPUT BO BINARY OUTPUT BV BINARY VALUE F.L. FAIL LAST N.C. NORMALLY CLOSED N.O. NORMALLY OPEN VFD VARIABLE FREQUENCY DRIVE MECHANICAL SCOPE OF WORK 1.0 REMOVE DOMESTIC HOT WATER, COLD WATER, RO, AND LAB WASTE PIPING SERVING THE SINK. 2.0 PROVIDE EXHAUST DUCT WITH BLAST GATE DAMPER TO SERVE TO MASS SPECTROMETER. 3.0 PERFORM PRE-CONSTRUCTION AND POST-CONSTRUCTION AIR BALANCING ON THE EXHAUST DUCTWORK SERVING LAB 204. DOCUMENT EXHAUST AIRFLOWS AT THE 24”X24” GENERAL EXHAUST AIR GRILLE WHILE THE FUME HOOD IS AT MAXIMUM SASH HEIGHT AND MINIMUM SASH HEIGHT. DOCUMENT EXHAUST AIRFLOWS AT THE 4” DUCT, SERVING THE MASS SPECTROMETER, WHILE THE FUME HOOD IS AT MAXIMUM SASH HEIGHT AND MINIMUM SASH HEIGHT. BALANCE THE 4” MASS SPECTROMETER EXHAUST DUCT TO A MINIMUM OF 25 CFM WHEN THE FUME HOOD SASH IS IN THE MAXIMUM POSITION. DUCT SCHEDULE AND SPECIFICATIONS DUCT SERVICE LOCATION PRESSURE CLASS SEAL CLASS DUCT MATERIAL LINING INSULATION MIN R-VALUE MATERIAL FIELD JACKET FINISH EXHAUST: LAB 3" NEG A STAINLESS STEEL NONE NONE - - NONE NOTES: 1. ALL DUCTWORK AND ACCESSORIES SHALL BE FABRICATED AND INSTALLED IN COMPLIANCE WITH THE LATEST ISSUE OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE. 2. CONSTRUCT TEES, BENDS, AND ELBOWS WITH RADIUS OF NOT LESS THAN 1.0 TIMES THE WIDTH OF DUCT ON CENTER LINES. 3. WHERE RECTANGULAR ELBOWS ARE USED, PROVIDE AIR FOIL TYPE TURNING VANES. 4. INCREASE DUCT SIZES GRADUALLY, AND IN COMPLIANCE WITH FIGURE 4-7 OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE. BRANCH CONNECTIONS SHALL BE MADE WITH A 45 DEGREE ENTRY. STRAIGHT TEES ARE NOT ACCEPTABLE. 5. SEALANTS AND GASKETS: SURFACE BURNING CHARACTERISTICS SHALL BE A MAXIMUM FLAME-SPREAD INDEX OF 25, AND MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED TO UL 723. 6. REMOVE SURFACE CONTAMINANTS AND DEPOSITS FROM DUCTWORK AND EQUIPMENT PRIOR TO TESTING AND BALANCING. 7. PROVIDE ESCUSION PLATE WHERE DUCT PENETRATES THROUGH THE CEILING, PROVIDE MANUAL BLAST DAMPER BELOW THE CEILING FOR VOLUME CONTROL. DUCT ACCESSORIES SCHEDULE TAG DESCRIPTION BASIS OF DESIGN SIZE MATERIALMANUFACTURER MODEL BG-1 STAINLESS STEEL, HEAVY DUTY 12 GA BODY AND BLADE BLASTGATE BGG04C 4"ø-4"ø 304 STAINLESS STEEL VD FRAMES: 16 GA GALVANIZED STEEL, HAT-SHAPED, MITERED AND WELDED CORNERS BLADES: 16 GA GALVANIZED STEEL, MULTIPLE BLADE, OPPOSED-BLADE DESIGN BLADE AXLE: GALVANIZED STEEL BEARINGS: MOLDED SYNTHETIC OPTIONS: LOCKING HAND QUADRANT FRAMES: 20 GA GALVANIZED STEEL BLADES: 20 GA GALVANIZED STEEL BLADE AXLE: GALVANIZED STEEL BEARINGS: MOLDED SYNTHETIC OPTIONS: LOCKING HAND QUADRANT RUSKIN MD35 16"x10"-16"x10" GALVANIZED STEEL MECHANICAL SUBMITTAL SCHEDULE SECTION TITLE REQUIRED 230529 HANGERS & SUPPORTS FOR HVAC PRODUCT DATA 230593 TESTING, ADJUSTING & BALANCING FOR HVAC QUALIFICATIONS, INSPECTION AND TEST REPORTS 233100 DUCTWORK PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 233300 AIR DUCT ACCESSORIES PRODUCT DATA FIELD VERIFY MECHANICAL GENERAL NOTES 1.0 DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED IN THE CONTRACT. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. IF DIMENSIONS OR CONDITIONS ARE FOUND TO BE IN CONFLICT WITH THE DRAWINGS, THE CONTRACTOR SHALL IMMEDIATELY REFER THE CONFLICT TO THE ENGINEER. 2.0 UTILITY SHUTDOWNS: SHUTDOWN OF ANY BUILDING UTILITY SYSTEM SHALL BE COORDINATED WITH CUSTOMER SERVICE AT PH: 607-255-5322. THE CONTRACTOR SHALL BEAR THE COST OF THE UTILITY SHUTDOWN. SCHEDULE WORK TEN DAYS IN ADVANCE AND NOTIFY THE OWNER'S REPRESENTATIVE TO COORDINATE BUILDING FUNCTIONS WITH THE BUILDING COORDINATOR. 3.0 ALL PENETRATIONS THROUGH FULL HEIGHT WALLS ARE TO BE FIRESTOPPED IN ACCORDANCE WITH UL STANDARDS. ALL GAPS AND JOINTS AT RATED FLOORS, ROOFS AND WALLS ARE TO BE FIRE AND SMOKE STOPPED. CAPS AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND CONTROL OR EXPANSION JOINTS. FIRESTOPPING INCLUDES BOTH FORM OR PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. 4.0 INSTALL EQUIPMENT TO ENSURE PROPER ACCESS AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. EQUIPMENT THAT IS NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. 5.0 ALL SYSTEM TESTING SHALL BE CONDUCTED PRIOR TO INSULATION, FIREPROOFING, AND ENCLOSURE IN SHAFTS. ANY RESTORATION WORK REQUIRED AS A RESULT OF DISTURBING FINISHES OR STRUCTURE IN ORDER TO ACCESS SYSTEMS REQUIRING REPAIR SHALL BE AT NO COST TO THE UNIVERSITY. 6.0 VERIFY FINAL EQUIPMENT/FIXTURE LOCATIONS FOR ROUGHING-IN. 7.0 ANY FIRESTOPPING DISTURBED DURING THE COURSE OF WORK SHALL BE REPAIRED TO MAINTAIN A 2-HOUR FIRE RATING. 8.0 CUTTING AND PATCHING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING, AND PATCHING TO COMPLETE THE WORK. WHERE EXISTING CONSTRUCTION IS REMOVED, CAUSING AN EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES, RESULTING SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. 1 9/30/2019 ISSUE FOR PROGRESS SET REVIEW 2 10/25/2019 ISSUE FOR 50% CD REVIEW 3 11/26/2019 ISSUE FOR 95% CD REVIEW 4 12/03/2019 ISSUE FOR COORDINATED REVIEW 5 12/16/2019 ISSUE FOR CONSTRUCTION 204 1 EXHAUST AIR VAV TB-55 (E) 25 CFM MINIMUM E1a 4" DIA 12" DIA. VD 204 REMOVE SINK AND ASSOCIATED PIPING AND FIXTURES. 1 CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 OLIN HALL OLIN HALL ROOM 204 LAB RENOVATION M-101 11982592 ROOM 204 DEMOLITION AND NEW WORK P. OCKENFELS PCO 2024 DECEMBER 16, 2019 0 2 4 8 SCALE: 1/4"=1'-0" SCALE:1/4" = 1'-0"2 2ND FLOOR NEW SCALE:1/4" = 1'-0"1 2ND FLOOR DEMOLITION M-101 KEYED CONSTRUCTION NOTES 1 4" ROUND EXHAUST AIR DROP ADJACENT TO THE MASS SPECTROMETER. TERMINATE 12" BELOW CEILING WITH BLAST GATE. COORDINATE EXACT LOCATION WITH LAB OWNER. PROVIDE ESCUTCHEON AT CEILING PENETRATION. # M-101 KEYED DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING SINK, TRIM AND ALL ASSOCIATED PIPING. REMOVE EXISTING SANITARY, VENT, DOMESTIC AND RO WATER PIPING BACK TO MAINS AND CAP. # 1 9/30/2019 ISSUE FOR PROGRESS SET REVIEW 2 10/25/2019 ISSUE FOR 50% CD REVIEW 3 11/26/2019 ISSUE FOR 95% CD REVIEW 4 12/03/2019 ISSUE FOR COORDINATED REVIEW 5 12/16/2019 ISSUE FOR CONSTRUCTION CORNELLUNIVER S IT Y F O U NDED5681ADFACILITIESENGINEERINGARCHIVE BAR CODEITHACA, NEW YORKARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:DATE:FACILITY:DESIGN:DRAWN:WWW.FCS.CORNELL.EDUIT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION.WARNINGREVISIONSARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING201 HUMPHREYS SERVICE BLDGITHACA, NEW YORK 14853-3701OLIN HALLOLIN HALL ROOM204 LABRENOVATIONE-00111982592GENERALNOTES ANDSYMBOLLEGENDSM. SCHOLENOMPS2024DECEMBER 16, 2019GENERAL ELECTRICAL NOTES1.0 ELECTRICAL SCHEMATICS INDICATED ON CONTRACT DOCUMENTS AREDIAGRAMMATIC. IT IS NOT THE INTENT TO SHOW EXACT OR MOST EFFICIENTROUTING. VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ON SITE. ANYCONFLICTS BETWEEN CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALLBE BROUGHT TO CORNELL'S PROJECT MANAGER FOR RESOLUTION BEFORE WORKPROCEEDS.2.0 ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOINING AREASFROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE AND DISPOSE OFWASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISES FREE OF DEBRIS FROMTHE EXECUTION OF WORK. DELIVER A FINAL PRODUCT THAT IS CLEAN ANDOPERABLE.3.0 FIRE STOP ELECTRICAL PENETRATIONS THROUGH FIRE RATED WALLS AND/ORFLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTION OF THEMATERIAL PENETRATED.4.0 WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACTDOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHOD OFINSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FOR APPROVALPRIOR TO ORDERING ANY MATERIALS OR COMMENCING EXECUTION OF WORK.5.0 GROUNDING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 250. PROVIDEEQUIPMENT GROUND CONDUCTOR WITH EACH BRANCH CIRCUIT INDICATED ONCONTRACT DOCUMENTS. EQUIPMENT GROUND CONDUCTOR SHALL BE ROUTEDWITH ASSOCIATED PHASE CONDUCTORS.6.0 PROVIDE A NEW TYPED PANELBOARD DIRECTORY FOR EACH PANELBOARD. LABELALL NEW DEVICE FACEPLATES WITH SOURCE AND CIRCUIT NUMBER. PROVIDEPERMANENT LABEL ON SWITCHING DEVICES INDICATING EQUIPMENT SERVICE ANDINVENTORY NUMBERS. COORDINATE EQUIPMENT INVENTORY NUMBERS WITHCORNELL UNIVERSITY'S MECHANICAL SHOP, 255-8667.7.0 CIRCUITS RATED 20-AMP, 120 VOLT SHALL CONTAIN SEPARATE NEUTRALCONDUCTORS.8.0 CONDUCTORS SHALL BE A MINIMUM OF 12AWG, STRANDED COPPER, 600VAC, 90DEGREE C, TYPE THHN/THWN-2 FOR DRY AREAS AND XHHW/THWN-2 FOR WETAREAS.9.0 CONDUITS SHALL BE A MINIMUM OF 3/4 INCHES DIAMETER. CONDUITS SHALL BEELECTRICAL METALLIC TUBING (EMT) AND SURFACE MOUNTED UNLESS NOTEDOTHERWISE.10.0 AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OF RESPECTIVEPANELBOARD. SIZE AS INDICATED.11.0 PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDE SUPPORTHANGERS FOR CONDUIT AS NEEDED.12.0 INSTALL RACEWAY SYSTEMS ENSURING PROPER ACCESS TO EQUIPMENT ANDDEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE ANDREPAIR. RACEWAYS THAT ARE NOT INSTALLED WITH THIS REQUIREMENT IN MINDSHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIESARE CORRECTED.ELECTRICAL SCOPE OF WORK1.0 DEMO EXISTING ELECTRICAL OUTLETS AND CIRCUITRY THAT ARE NO LONGERNEEDED.2.0 PROVIDE DEDICATED ELECTRICAL CIRCUITS FOR THE PROPOSED NEW OWNERPROVIDED EQUIPMENT.3.0 PROVIDE EMERGENCY CIRCUIT TO OWNER PROVIDED UPS FOR NEW OWNERPROVIDED EQUIPMENT AS REQUIRED.ELECTRICAL LEGENDLIGHTING LEGENDMOTOR1'x4' LUMINAIREHARDWIRED EQUIPMENT CONNECTIONP-1A12HOMERUN TO PANEL P-1A, CIRCUIT #12. FED FROM 20A -1P BREAKER IS INTENDED UNLESS NOTED OTHERWISE. RUN GREEN WIRE GROUND FOR ALL CIRCUITS. PROVIDE ONE GROUND PER CIRCUIT.EMERGENCY POWER OFF (EPO)GROUND ROD ELECTRODEDUPLEX RECEPTACLE WITH GFCI PROTECTIONDUPLEX RECEPTACLE WITH AFCI PROTECTIONQUAD RECEPTACLELINETYPES LEGENDSIMPLEX RECEPTACLE: NEMA 5-20RPANELBOARDJUNCTION BOXB = INSTALLED IN BASEBOARDTR = INSTALLED IN WOOD TRIM/CASEWORK/WAINSCOTTSR = SURFACE RACEWAYWP = WEATHERPROOFAC = AIR CONDITIONERPP = POWER PENDANT OUTLET BOXDUPLEX RECEPTACLE: DOUBLE DUPLEX RECEPTACLEMOTOR STARTERJ2'x4' LUMINAIRECEILING MOUNTED LUMINAIREEM LIGHTING BATTERY UNITCOMBO EXIT SIGN/EM LIGHTING BATTERY UNITSINGLE FACE, WALL MOUNT EXIT SIGNDOUBLE FACE, WALL MOUNT EXIT SIGNSINGLE FACE, CEILING MOUNT EXIT SIGNDOUBLE FACE, CEILING MOUNT EXIT SIGNLIGHT SWITCH:SAFETY SWITCH (NON-FUSED)SAFETY SWITCH (FUSED)X3 = 3-WAY SWITCH4 = 4-WAY SWITCHD = DIMMER SWITCHO = WALL SWITCH OCCUPANCY SENSORV = WALL SWITCH VACANCY SENSORW = WIRELESS SWITCHS = WIRELESS SCENE SWITCHWIRELESS OCCUPANCY SENSORWIRELESS DAYLIGHT SENSOROSWDS1'x2' LUMINAIREFIRE ALARM LEGENDFIRE ALARM CONTROL PANELBATTERY CABINETWATER FLOW SWITCHMUXPADREMOTE ANNUNCIATORD = DUCT SMOKE DETECTORR = RELAY BASEBR = BEAM RECEIVERBT = BEAM TRANSMITTERSB = SOUNDER BASESMOKE DETECTOR: TAMPER SWITCHAUDIBLE NOTIFICATION APPLIANCEFACPBATTMUXFAANAC PANELNACMANUAL PULL STATIONFSXF = FIXED TEMPERATURER = RATE OF RISER/F = COMBINATION RISE/FIXED TEMPERATUREHEAT DETECTOR: HXCARBON MONOXIDE DETECTORCOAMFXXcdCFSFSXXcdCTSADDRESSABLE MODULEXXcd = CANDELAC = CEILINGCOMBO A/V NOTIFICATION APPLIANCE: XXcd = CANDELAC = CEILINGVISUAL NOTIFICATION APPLIANCE:SUPPRESSION SYSTEMELECTRICAL ABBREVIATIONSAC AIR CONDITIONERAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAFI ARC FAULT INTERRUPTERAMM ADDRESSABLE MONITOR MODULEAOM ADDRESSABLE OUTPUT MODULEARB AUXILIARY RELAY BOARDATS AUTOMATIC TRANSFER SWITCHB BASEBOARDBKR BREAKERC CONDUITCD CANDELACKT CIRCUITCR CONTROL RELAYEC ELECTRICAL CONTRACTOREMT ELECTRICAL METALLIC TUBINGEPO EMERGENCY POWER OFF STATIONFAA FIRE ALARM ANNUNCIATOR PANELFACP FIRE ALARM CONTROL PANELFSD FIRE SMOKE DAMPERGAA GENERATOR ALARM ANNUNCIATORGFI GROUND FAULT INTERRUPTERGND GROUNDHP HORSEPOWERKW KILOWATTLC LIGHTING CONTACTORLFMC LIQUID TIGHT FLEXIBLE METALLIC CONDUITLTG LIGHTINGMCB MAIN CIRCUIT BREAKERMLO MAIN LUG ONLYMTS MANUAL TRANSFER SWITCHNAC NOTIFICATION APPLIANCE CIRCUITNIC NOT IN CONTRACTOE OVERHEAD ELECTRICPC PHOTOCELLPM PLUGMOLDPP POWER PANELPPO PENDANT POWER OUTLETPVC POLYVINYL CHLORIDE CONDUITRGS RIGID GALVANIZED STEEL CONDUITSR SURFACE RACEWAYST SHUNT TRIPTM THERMAL MAGNETICTR TRIM/CASEWORK/WAINSCOTTTSP TWISTED SHIELDED PAIRTYP TYPICALUE UNDERGROUND ELECTRICUON UNLESS OTHERWISE NOTEDUPS UNINTERRUPTIBLE POWER SUPPLYV VOLTSVA VOLT AMPSWP WATERPROOFUNDERGROUND ELECTRICUEUNDERGROUND LIGHTINGULOVERHEAD ELECTRICOETO BE PROVIDEDDEMOLITION / TO BE RELOCATEDEXISTING TO REMAINUNDERGROUND TELCOUCMOUNTING HEIGHTSCARD READER 48" TOP OF BOXLIGHT SWITCH 48" TOP OF BOXRECEPTACLE 18" TOP OF BOXDATA OUTLET 18" TOP OF BOXTV OUTLET 84" TOP OF BOXPHONE OUTLET 48" TOP OF BOXSAFETY SWITCH 60" CENTERLINE OF HANDLEMOTOR STARTER 60" CENTERLINE OF HANDLEPANELBOARD 72" TOP OF PANELBOARDMANUAL PULL STATION 48" OPERABLE HANDLENOTIFICATION APPLIANCE 80" BOTTOM OF LENSDOOR HOLD OPEN COORDINATE IN FIELDEM BATTERY UNIT 96" BOTTOM OF UNITEM REMOTE UNIT 102" BOTTOM OF UNITEXIT SIGN 96" BOTTOM OF UNITLIGHT POLE WITH LED LUMINAIRES, REFER TO PLANS FOR NUMBER AND CONFIGURATION OFHEADSGENERAL ELECTRICAL DEMOLITION NOTES1.0 ELECTRICAL EQUIPMENT SHOWN DASHED ON DEMOLITION DRAWINGS, INCLUDINGASSOCIATED ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS, AND OTHERAPPURTENANCES NOT SHOWN, SHALL BE DISCONNECTED AND REMOVED.REMOVE ASSOCIATED BRANCH CIRCUITRY TO SOURCE, UNLESS NOTEDOTHERWISE.2.0 EXISTING RACEWAYS AND DEVICE BACKBOXES NOT INTERFERRING WITH NEWWORK SHALL BE REUSED WHERE POSSIBLE.3.0 PROVIDE JUNCTION BOXES, RACEWAYS, AND WIRING TO MODIFY/EXTEND EXISTINGSYSTEMS AND CIRCUITS FED DOWNSTREAM OF ELECTRICAL EQUIPMENT SHOWNTO BE DEMOLISHED.4.0 CUT DEMOLISHED CONDUITS INSTALLED THRU WALLS AND FLOORS FLUSH WITHTHE SURFACE AND PATCH PENETRATIONS (FIRESTOP IF LOCATED ON A FIRERATED SURFACE). PATCH AND PAINT SURFACES IN EXPOSED AREAS TO MATCHSURROUNDING MATERIALS, FINISHES, AND COLORS.5.0 PROVIDE BLANK COVERPLATES ON UNUSED BACKBOXES REMAINING FROMDEMOLITION NOT SPECIFIED TO BE INFILLED.6.0 EXISTING EQUIPMENT SHOWN TO REMAIN SHALL BE PROTECTED DURINGCONSTRUCTION.SPECIAL RECEPTACLE: NEMA CONFIGURATION NEXT TO SYMBOL OR IN EQUIPMENT SCHEDULE5-30R1 9/30/2019 ISSUE FOR PROGRESS SET REVIEW2 10/25/2019 ISSUE FOR 50% CD REVIEW3 11/26/2019 ISSUE FOR 95% CD REVIEW4 12/03/2019 ISSUE FOR COORDINATED REVIEW5 12/16/2019 ISSUE FOR CONSTRUCTION DNUP202204206206ALP2A11ELP2ASD2E-1012E-1013200CB208210212211209207205203201A2016FLEPP-2HELP-2HLP-2LPP-28204PPOPPOLP2A11111222231UNDER ELECTRIC PANEL1204-86° FREEZERWATER PURIFICATION SYSTEMPPOPPOELECTROPHORESIS SYSTEM4° FRIDGELP2A113PPO14E5a2E2aE9aE7aE4aE6aE1aE3a5INCUBATOR SHAKER CENTRIFUGE-20° FREEZER1E8aINCUBATOR 711E11aE10aOWNER PROVIDED MASS SPECOWNER PROVIDED NITROGEN GENERATOREMTEMTTO LEPP-2NEMA 6-15R FOR -86° FREEZERPOWER PENDANT OUTLET BOX WITH STRAIN RELIEF MOUNTED FROM EXISTING RACEWAY. CIRCUIT FROM 40A/2P CIRCUIT BREAKER IN PANEL LEPP-2. EXISTING CEILING MOUNTED RACEWAY CABLE/CORD GRIP STRAIN RELIEF CABLE/CORD GRIP STRAIN RELIEF NEMA 6-50R RECEPTACLE OWNER PROVIDED UPSOWNER PROVIDED FREEZERSURFACE RACEWAYEXISTING CEILINGNEMA 6-15P PLUG FOR FREEZERJUNCTION BOXCORNELLUNIVER S IT Y F O U NDED5681ADFACILITIESENGINEERINGNARCHIVE BAR CODEITHACA, NEW YORKARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:DATE:FACILITY:DESIGN:DRAWN:WWW.FCS.CORNELL.EDUIT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION.WARNINGREVISIONSARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING201 HUMPHREYS SERVICE BLDGITHACA, NEW YORK 14853-3701OLIN HALLOLIN HALL ROOM204 LABRENOVATIONE-10111982592RENOVATIONPLANSM. SCHOLENOMPS2024DECEMBER 16, 2019#E-101 KEYED DEMOLITION NOTES1 DISCONNECT AND REMOVE EXISTING OUTLET. REMOVE EXISTING CIRCUIT BACK TOSOURCE.2 EXISTING WALL MOUNTED STEEL RACEWAY SIMILAR TO WIREMOLD 3000 TOREMAIN. VERIFY IN FIELD.3 EXISTING CEILING MOUNTED STEEL RACEWAY SIMILAR TO WIREMOLD 4000 TOREMAIN. VERIFY IN FIELD.0 4 816SCALE: 1/8"=1'-0"SCALE:1/8" = 1'-0"12ND FLOOR PARTIAL FLOOR PLANSCALE:1/4" = 1'-0"2LAB 204 DEMOLITION PLANSCALE:1/4" = 1'-0"3LAB 204 RENOVATION PLANE-101 KEYED CONSTRUCTION NOTES1 PROVIDE DEDICATED NEMA RECEPTACLE IN EXISTING RACEWAY AND BRANCHCIRCUIT FROM EXISTING SPARE 20A/1P CIRCUIT BREAKER IN PANEL LP2A11. REFERTO EQUIPMENT SCHEDULE FOR NEMA RATING AND CIRCUIT INFORMATION.PROVIDE ¾” EMT CONDUIT FROM SURFACE RACEWAY TO ELECTRIC PANEL.2 PROVIDE 8/3 SOOW BLACK 90C, 40 AMP, 600V HEAVY DUTY RUBBER CABLE ANDPOWER PENDANT OUTLET BOX WITH NEMA 6-50R RECEPTACLE AND STRAIN RELIEFFOR NEW UPS. PROPERLY SIZE STRAIN RELIEF FOR CEILING RACEWAY ANDOUTLET BOX CONNECTION. CONNECT TO EMERGENCY BRANCH CIRCUIT FROMNEW 40A/2P CIRCUIT BREAKER IN EMERGENCY PANEL LEPP-2 IN EXISTING CEILINGMOUNTED RACEWAY. CIRCUIT WITH 2#8 AWG & 1#8 AWG GROUND CONDUCTORS IN¾” EMT CONDUIT. COORDINATE CORD LENGTH IN FIELD WITH EQUIPMENT ANDOWNER. RECEPTACLE COLOR SHALL BE RED.3 PROVIDE DEDICATED NEMA 6-15R RECEPTACLE FOR FREEZER IN SURFACEMOUNTED RACEWAY SIMILAR TO WIREMOLD 3000 SERIES STEEL RACEWAY.EXTEND TO ABOVE CEILING TO JUNCTION BOX FOR CONNECTION TO CIRCUIT FROMUPS. CIRCUIT WITH 2#12 AWG & 1#12 AWG GROUND CONDUCTORS. RUN CIRCUIT IN¾” EMT CONDUIT FROM RACEWAY JUNCTION BOX ABOVE CEILING OVER TOEXISTING CEILING MOUNTED SURFACE RACEWAY. RECEPTACLE COLOR SHALL BERED.4 PROVIDE 12/3 SOOW BLACK 90C, 20 AMP, 600V HEAVY DUTY RUBBER CABLE WITHNEMA 6-15P PLUG AND STRAIN RELIEF FOR FREEZER CIRCUIT. PROPERLY SIZESTRAIN RELIEF FOR CEILING RACEWAY CONNECTION. SPLICE SOOW CABLE TOFREEZER OUTLET CIRCUIT IN CEILING RACEWAY AND PLUG SOOW CABLE INTO NEWUPS NEMA 6-15R RECEPTACLE. COORDINATE CORD LENGTH IN FIELD WITHEQUIPMENT AND OWNER. PLUG COLOR SHALL BE RED.5 PROVIDE TWO (2) NEMA 5-20R DUPLEX RECEPTACLES IN EXISTING RACEWAYCIRCUITED FROM ONE EMERGENCY BRANCH CIRCUIT. CIRCUIT WITH 2#10 & 1#10AWG GND CU CONDUCTORS FROM EXISTING SPARE 20A/1P CIRCUIT BREAKER INPANEL LEPP-2. PROVIDE ¾” EMT CONDUIT FROM SURFACE RACEWAY TO ELECTRICPANEL. RECEPTACLE COLOR SHALL BE RED.6 PROVIDE 1-40A/2P CIRCUIT BREAKER FOR OWNER PROVIDED UPS. REMOVE 2EXISTING 1P SPARE CIRCUIT BREAKERS IN EXISTING PANEL TO MAKE ROOM FORNEW 2P CIRCUIT BREAKER. MATCH EXISTING PANEL TYPE AND AIC RATINGS.7 PROVIDE TWO (2) NEMA 5-20R DUPLEX RECEPTACLES IN EXISTING RACEWAYCIRCUITED FROM ONE BRANCH CIRCUIT. CIRCUIT WITH 2#12 & 1#12 AWG GND CUCONDUCTORS FROM EXISTING SPARE 20A/1P CIRCUIT BREAKER IN PANEL LP2A11.PROVIDE ¾” EMT CONDUIT FROM SURFACE RACEWAY TO ELECTRIC PANEL.8 PROVIDE 1 SPARE 1” EMT CONDUIT FROM PANEL LEPP-2 TO ABOVE CEILING IN LAB204 FOR FUTURE USE. PROVIDE PULL STRING IN EMPTY RACEWAY.0 2 4 8SCALE: 1/4"=1'-0"#EQUIPMENT ELECTRIC CONNECTION SCHEDULELABEL DESCRIPTION EQUIPMENT MANUFACTURERROOMNO.PANEL OCPRATING(kW, W,VA, A, HP)VOLTAGE PHASE WIRE & CONDUITRECEPTACLEQUANTITYNOTESNEMA RATINGE1a LC/MS LIQUID CHROMATOGRAPH MASS SPECTROMETER AGILENT 6500 SERIES 204 LEPP-2 - 2850 W 208 1 -6-15R 2 CONNECT TO UPSE2a NITROGEN GENERATORPEAK SCIENTIFIC NM32LA 204 LEPP-2 - 1265 W 110 1 -5-20R 1 CONNECT TO UPSE3a FREEZER (-86° C)EPPENDORF U410 204 LEPP-2 - 8 A 208 1 -6-15R 1 CONNECT TO UPSE4a UNDERCOUNTER -20°C FREEZER EXISTING 204 LP2A11 20A/1P 2.2 A 120 1 2#12&1#12GND IN 3/4" EMT 5-20R 1 DEDICATED CIRCUITE5a UNDERCOUNTER 4°C REFRIGERATOR EXISTING 204 LP2A11 20A/1P 2.2 A 120 1 2#12&1#12GND IN 3/4" EMT 5-20R 1 DEDICATED CIRCUITE6a ELECTROPHORESIS POWER SUPPLY BIO RAD POWERPAC BASIC 204 LP2A11 20A/1P 75 W 120 1 2#12&1#12GND IN 3/4" EMT 5-20R 1E7a INCUBATOR SHAKERINNOVA 42R 204 LP2A11 20A/1P 1800 W 120 1 2#12&1#12GND IN 3/4" EMT 5-20R 1 DEDICATED CIRCUITE8a INCUBATORTHERMOFISHER 3110 204 LP2A11 20A/1P 432 W 115 1 2#12&1#12GND IN 3/4" EMT 5-20R 2 PROVIDE ONE (1) DEDICATED CIRCUIT FOR 2 OUTLETSE9a CENTRIFUGEEPPENDORF 5910R 204 LP2A11 20A/1P 1650 W 120 1 2#12&1#12GND IN 3/4" EMT 5-20R 1 DEDICATED CIRCUITE10a MILLI Q WATER PURIFICATION SYSTEM EMD MILLIPORE 204 LP2A11 20A/1P - 115 1 2#12&1#12GND IN 3/4" EMT 5-20R GFCI 1 THIS CAN PLUG INTO EXISTING RECEPTACLEE11a UNINTERRUPTIBLE POWER SUPPLY POWERVAR 204 LEPP-2 40A/2P 6000VA 208 1 2#8 & 1#8 GND IN 3/4" EMT 6-50R 1 DEDICATED CIRCUITSCALE:NO SCALE4UPS - EMERGENCY CIRCUIT ELEVATION DETAIL1 9/30/2019 ISSUE FOR PROGRESS SET REVIEW2 10/25/2019 ISSUE FOR 50% CD REVIEW3 11/26/2019 ISSUE FOR 95% CD REVIEW4 12/03/2019 ISSUE FOR COORDINATED REVIEW5 12/16/2019 ISSUE FOR CONSTRUCTION