Loading...
HomeMy WebLinkAboutWegmans - Code Compliance Work - 10-18-191. THE AREA OF WORK FOR THIS PROJECT HAS BEEN DESIGNED TO MEET THE FOLLOWING REQUIREMENTS OF THE: NYS UNIFORM FIRE PREVENTION AND BUILDING CODE WITH 2017 UNIFORM CODE SUPPLEMENTS, AS APPLICABLE INTERNATIONAL EXISTING BUILDING CODE, 2015 (IEBC) INTERNATIONAL BUILDING CODE, 2015 (IBC) ICC A117.1 - 2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES INTERNATIONAL FIRE CODE, 2015 (IFC) NYS ENERGY CONSERVATION CONSTRUCTION CODE - INTERNATIONAL ENERGY CONSERVATION CODE - 2015 (IECC) WITH 2016 ENERGY CODE SUPPLEMENTS, AS APPLICABLE REFER TO ENGINEERING DRAWINGS FOR THE AREA OF WORK DESIGNED IN COMPLIANCE WITH OTHER APPLICABLE CODE SECTIONS 2. THE ORIGINAL BUILDING CONSTRUCTION WAS COMPLETED IN 1997. 3. CONSTRUCTION CLASSIFICATION TYPE: IIB 4. OCCUPANCY CLASSIFICATION: USE GROUP (M) MERCANTILE, SUPERMARKET 5. ALLOWABLE BUILDING AREA: UNLIMITED (EXISTING FIRE WALL AT RECEIVING) 6. THE BUILDING IS PROVIDED WITH AN AUTOMATIC FIRE PROTECTION SPRINKLER SYSTEM PER NFPA-13, AND SHALL BE MAINTAINED IN THE AREA OF WORK. THE NFPA SPRINKLER SYSTEM IS MONITORED AS REQUIRED BY IBC SECTION 903.4. 7. CLASSIFICATION OF WORK: ALTERATION - LEVEL 2 8. AREA/OCCUPANCY LOADS EXISTING BUILDING 1ST FLOOR AREA: 115,110 S.F. OCCUPANCY: 2,808 PEOPLE MEZZANINE AREA: 7,848 S.F. OCCUPANCY: 208 PEOPLE ALTERATION 1ST FLOOR AREA: 1000 S.F. OCCUPANCY: 5 PEOPLE MEZZANINE AREA: N/A S.F. OCCUPANCY: N/A PEOPLE 9. MAXIMUM TRAVEL DISTANCE ALLOWED: 250' AREA OF WORK- NO CHANGE IN TRAVEL DISTANCE 10. MAXIMUM DEAD END CORRIDOR ALLOWED: 35' AREA OF WORK- NO DEAD END CORRIDORS 11. MINIMUM EXIT CORRIDOR WIDTH REQUIRED: 44" AREA OF WORK- NO CHANGE IN CORRIDOR WIDTH 12. TOTAL BUILDING EGRESS WIDTH REQUIRED: 452" TOTAL BUILDING EGRESS WIDTH ACTUAL: 634" AREA OF WORK- NO CHANGE IN EGRESS WIDTH (UPDATE 8/10/2017) N ProjectNo:DRWNBY:MICHAEL JOHN SORENSEN NY STATE REG.# 033368 Date:CHECKEDBY:FOODMARKETS,INC.SCALE:ASNOTEDStore No: PRICING SET: PERMIT SET: CONST SET:280EastBroadStreetRochester,NewYork14604UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209.7/3/20198:41:57AMC:\RevitProjects\071_5266_Ithaca_ANNO_CENTRAL_v2017_bthompson.rvtITHACA,NY#71A000OLDEWORLDCHEESEREMODEL 071-526607/03/19PERMIT SET 07/03/19 MJSBJT500SMEADOWST.ITHACA,NY14850#071 COVERSHEETA000 COVER SHEET A801 DEMOLITION AND NEW EQUIPMENT PLANS Project #: Status: Issue Date: Store #: OLDE WORLD CHEESE REMODEL PERMIT SET 500 S MEADOW ST. ITHACA, NY 14850 071-5266 07/03/19 #071 DRAWING INDEX AREA OF WORK Revision Schedule #Date Revision 1 07/03/19 PR# 071-5266 2 07/03/19 RB 71-INT-405 PERMIT SET ANDREW M. CUOMO GOVERNOR CLARISSA M. RODRIGUEZ CHAIR Office of the Secretary I, Kim McCarroll, Secretary for the Workers' Compensation Board, DO HEREBY Certify that: has secured compensation to its employees as a self-insurer in the following manner: The status of the self-insurer was effective as noted above and remains in full force. Compliance With Workers' Compensation Law Name:Wegmans Food Markets, Inc. WCB #:W665509 Tax ID #:16-1309424 Qual Date:4/30/1996 Pursuant to Section 50, subdivision 3 of the Workers' Compensation Law. Status Confirmed By Office of Self Insurance (518) 402-0247 SelfInsurance@wcb.ny.gov 8/12/2019 KIM MCCARROLL SECRETARY IN WITNESS WHEREOF, I have hereunto set my hand and affixed the seal of the Workers' Compensation Board this 12th day of August 2019. SI-12 8/1/2012 328 State Street, Schenectady, NY 12305 (518) 402-0247 www.WCB.NY.gov ANDREW M. CUOMO GOVERNOR CLARISSA M. RODRIGUEZ CHAIR NOTICE OF COMPLIANCE The above named employer is in compliance with the New York State Disability and Paid Family Leave Benefits Law with respect to all of his or her employees by approved self-insurance or a combination of self-insurance and insurance with an authorized carrier(s). Self-Insurance coverage for the program(s) checked above was effective as noted and remains in full force. AS SELF-INSURER UNDER THE NEW YORK STATE DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW Employer:Wegmans Food Markets, Inc. Carrier ID #.:B902005 FEIN:16-1309424 Qualification Date (DB):7/1/1964 Qualification Date (PFL):1/1/2018 Status Confirmed By Office of Self Insurance (518) 402-0247 SelfInsurance@wcb.ny.gov 8/12/2019 Disability Benefits Paid Family Leave DB-155 9/1/2016 328 State Street, Schenectady, NY 12305 (518) 402-0247 www.WCB.NY.gov AC Rt1 CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) 04/24/2019 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER MARSH USA INC. 70 LINDEN OAKS, SUITE 310 ROCHESTER, NY 14625 CN101851007-ALL-GAEW-19-20 CONTACTCO PHONE FAX (A/C. No. Ext): (A/C, No): EMAIL ADDRESS: INSURER(S) AFFORDING COVERAGE NAIC # INSURER A : Travelers Property Casualty Co. of America 25674 INSURED WEGMANS FOOD MARKETS, INC. 1500 BROOKS AVENUE PO BOX 30844 ROCHESTER, NY 14603-0844 INSURER B : ACE Property and Casualty Insurance Company 20699 INSURER C : INSURER D $ INSURER E : INSURER F : CERTIFICATE N • THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL _IVSD SUER WVD POLICY NUMBER POLICY EFF (MM/DD/YYYY) POLICY EXP (MM/DD/YYYY) LIMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ CLAIMS -MADE OCCUR DAMAGE TO RENTED PREMISES (Ea occurrence) $ MED EXP (Any one person) $ PERSONAL & ADV INJURY $ GEN'L AGGREGATE POLICY OTHER: LIMIT APPLIES PELT PER: LOC GENERAL AGGREGATE $ PRODUCTS - COMP/OP AGG $ $ A AUTOMOBILE X X LIABILITY ANY AUTO OWNED AUTOS ONLY HIRED AUTOS ONLY X SCHEDULED AUTOS NON -OWNED AUTOS ONLY TC2J-CAP-101 D6063-19 04/30/2019 04/30/2020 COMBINED SINGLE LIMIT (Ea accident) $ 2,000,000 BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident) $ LIABILITY DEDUCTIBLE $ B X UMBRELLA LIAB EXCESS LIAB X OCCUR CLAIMS -MADE XO0G27977741 004 EXCESS OF GENERAL LIABILITY RETAINED LIMIT LISTED BELOW 04/30/2019 04/30/2020 EACH OCCURRENCE $ 5,000,000 AGGREGATE $ 5,000,000 DED RETENTION $ $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANYPROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBEREXCLUDED? (Mandatory In NH) If yes, describe under DESCRIPTION OF OPERATIONS below Y / N N N/A PER STATUTE OTH- ER E.L. EACH ACCIDENT $ E.L. DISEASE - EA EMPLOYEE $ E.L. DISEASE - POLICY LIMIT $ RETAINED LIMITS APPLICABLE TO GENERAL LIABILITY $4,000,000 PROD/CO GENERAL AGG. $11,000,000 $2,000,000 0cc. DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) RE: EVIDENCE OF COVERAGE ATE HOLDER CANCELLATION CITY OF ITHACA 108 EAST GREEN STREET ITHACA, NY 14850 ACORD 25 (2016/03) SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh USA Inc. Annette M. Smith © 1988-2016 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Subject: Self-insured General Liability Certificate of Insurance Excess Policy Period 4/30/19 — 4/30/20 To Whom It May Concern: April 30, 2019 Please be advised that Wegmans Food MarketsInc. self -insures General Liability and has continuously since April 30, 1996. The 'per occurrence' self-insured limit has been and is currently $2,000,000.00. The aggregate limit of liability is currently $11,000,000.00 per policy period. Above these limits, Wegmans Food Markets, Inc. is insured. Where required by written agreement, Wegmans Food Markets Inc. will provide additional insured status vvithinthese|#nsuredretention,adheringtoandfoUoxvingpoUcypnovisiVnsassetforthintheumnbreUapo|icy shown on the attached certificate of insurance. Further, ACORD 25 provided by the insurance agent/broker, must be completed such that it is representative of the insurance for which that agent/broker is responsible. The agent/broker is not responsible for self- insurance. The enclosed certificate of insurance meets these requirements. Sincerely, Molly . Zup Insurance Manager Wegmans Food MarketsInc. Wegmans Food Markets, Inc. Corporate Office: 1500 Brooks Ave. • PO Box 30844 • Phone 585-328-2550 • Wegmans.com 10-CAS0317 1 0 -C A S 0 2 9 8 00-GRD000400-GRD0004 00-GRD000400-GRD0004 10-CAS0298 10-SCL006710-SCL006710-WPR000210-CAB002710-CAB002710-TBL0464 10-CAS023910-TBL046410-TBL046410-TBL04641 0 -T B L 0 4 6 4 10-CAS0239 10-CAS023910-CAS0299TBL0631 VIF WIDTH VIF DEPTH E E.4 F G 6.9 H 10 9 8 7 6.8 6.7 6 H.1G.5.3G.5.2 5 4.6 Y.4 Y.3 Y.2 Y.1 8.6 Z.1 D D 1 2"ø DCWS 1 1/2"ø DWHS 3/4"ø DHWRC 2"ø DWHS 2"ø DCWS 3/4"ø DCWS 3/4"ø DWHS 3/4"ø DCWS 3/4"ø DWHS 20' - 0 1/4"145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.1/8"=1'-0"7/2/2019 2:42:14 PMC:\Users\monom\Documents\071_Ithaca_PLUMB_CENTRAL_2017_monomCVV2R.rvtITHACAM508D_2OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 ASTEY500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/2019 TBD QUADRANT 2 DOMESTIC WATER SERVICE DEMO PLANN KEY PLAN N.T.S 5 3 1 B D F 10 H M508D_3 M508D_2 M508D_4 M508D_1 Revision Schedule # Date Revision 1 07/03/19 PERMIT SET PLM042 OLD WORLD CHEESE REMODEL DEMO NOTES: REMOVE 3/4" HOT & COLD WATER DROPS TO SINK (SNK0050) FROM INDICATED DISCONNECT POINTS SALVAGE SINK & AND ALL ACCESSORIES FOR RELOCATION.1 C O F F E E B E A N C A BIN E T17-DPR003617-DPR003617-DPR00361 7-D P R 0 0 3 6 17-COFFEE ROASTER 17-CAB0805 17-CAB0978 17-CAB0984 17-CAB0805 17-CAB0852 17-CAB0806 1 7 -B I N 0 1 5 1 17-REF016717-REF0167 17-REF0167 17-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-CAB092817-DPR010717-DPR010717-DPR0107 17-REF016717-REF0112 17-OVN0107 17-OVN0103 17-DPR0130 17-RGS0004 17-DPR0128 17-DPR012017-REF0244 17-REF0219 17-CPA0035 17-GDR0008 17-GDR000817-SCL005817-GDR0008 17-COFFEE BEAN CABINET 17-COFFEEBEANCABINET 17-CAB0747 1 7-C O F F E E B E A N C A BIN E T 17-MXR002917-MXR002917-MXR0029 17-OVN010717-DPR003617-DPR003617-DPR0036 17-DPR003617-DPR003617-DPR0036 1 7-D P R 0 0 3 6 1 7-D P R 0 0 3 6 1 7- D P R 0 0 3 6 1 7-D P R 0 0 3 6 17-REF0285 17-GDR0026 17-WRM0065 17-TELEPHONE 17-BIN0024 17-GDR0027 17-SNK0253 17-SNK0508 17-CPA0039 10-CAS0317 1 0-CA S 02 9 8 00-GRD000400-GRD0004 00-GRD000400-GRD0004 10-CAS0298 03-CAS010403-CAS010407-CAS010507-CAS010507-CAS010507-CAS010507-CAS0206 00-GRD000600-GRD0006 07-STG023307-SCN0001 07-MNR0015 07-RGS0004 07-WKS019607-PNT001407-WKS019507-CAB037707-WKS023507-MED000107-FRZ006407-SHF0122 07-SHF012207-SHF0122 07-SHF0122 07-SHF012207-SHF0123 07-SHF0122 07-SHF0122 07-SHF0123 07-SHF012507-SHF012507-SHF012207-SHF012307-CAB057107-CAB057107-CAB036707-CAB036707-DPR010807-PNT001107-CAB036707-CAB036707-DPR010807-MNR00 1507-MNR001507-PNT001007-CAB036707-CAB036707-DPR010807-CAB036707-CAB036707-DPR01080 7 -MNR0 01 507-MNR001507-SNK015207-CAB034107-CAB010507-CAB017407-CAB010607-REF009607-CAB010607-CAB017407-CAB046007-CAB046107-CAB046107-MNR001507-CAB026607-CAB026607-CAB038407-CAB026607-CAB038407-CAB026607-MNR001507-PNT001407-MNR001507-SHF012207-SHF0123 07-WKS019607-WKS019607-WKS0196 07-CAB0378 07-SCN0001 07-MNR0015 07-RGS000407-CAB0378 07-SCN0001 07-MNR0015 07-RGS000407-CAB0378 07-SCN0001 07-MNR0015 07-RGS000407-MNR001507-PNT001407-WKS019507-MNR001507-CAB037707-PNT001407-CAB038407-WKS023507-MNR001507-PNT001407-MNR001507-CAB046307-CAB038407-STG0233 07-STG0233 10-SCL006710-SCL006710-WPR000210-CAB002710-CAB002707-DRG0009VIF WIDTH07-SHF020307-SHF0203 07-MNR001500-REF0242 10-TBL0464 10-CAS023910-TBL046410-TBL046410-TBL04641 0 -T B L 0 4 6 4 10-CAS0239 10-CAS023910-CAS029907-SCN0001 07-SCN0001 07-SCN0001 07-SCN0001 07-CPA003507-CPA003507-CPA003507-CPA003507-CPA003507-PNT002407-PNT002407-PNT002407-PNT002407-PNT002407-RGS000407-STG023407-STG0234 07-STG023407-STG023407-STG023407-STG023407-STG023407-SCN001507-SCN001507-PNT001007-CPA003307-CPA003307-CPA003307-CPA003307-FAX 07-TELEPHONE07-TELEPHONE 07-TELEPHONE 07-WKS020924-STG010924-STG0109 24-STG010924-STG01092 4-S TG 0 1092 4-S TG 0 10924 -S T G 01 0 9 24-TBL0722 ADA 24-TBL0722 ADA 27-DIV0079 27-DIV0079 27-DIV0079 27-DIV0079 27-DIV0079 27-CPA0039 27-CPA0039 27-CPA0039 27-CPA003927-CPA0035 27-CPA0035 27-CPA0035 27-CPA003527-RGS000427-RGS000427-RGS000427-RGS000427-SCN0008 27-SCN0008 27-SCN0008 27-SCN000827-WKS039927-WKS0398 27-WKS0398 27-WKS040000-GRD000400-GRD0004 04-CAS0104 04-CAS0104 86-VND000486-TBL060086-SLC000986-TBL060086-SNK004886-REF016786-WRM005686-OVN011686-TBL069386-REF020186-TBL069386-REF020186-CAB085886-TBL032086-DPR009386-ICM004486-CAB002786-DSK0004 86-TBL006286-RKM015238-KTL001338-KTL001338-SCL0067 38-SCL006738-SHF0258 38-SHF0258 38-SHF0258 38-SHF0258 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 38-REF0124 38-REF0124 38-SHF0258 38-SHF025838-TBL035938-FDP0004 38-FDP0022 38-WPR0002 38-SHF022938-SHF0229 38-TBL048138-SNK0062CAB029938-SNK025538-TBL032038-OVN014638-RKM003238-RKM003238-RKM003238-CRT0007 38-CRT000438-CRT000438-CRT000438-CRT0004 38-RKM003238-RKM003238-CRT0007 38-RKM0032 38-RKM0032 38-SHF0258 38-SHF0258RKF0073 RKF007338-SNK025338-CNV002938-TBL0631VIF WIDTHVIF DEPTHTBL0631 VIF WIDTH VIF DEPTH 18-CRT000418-CRT000488-WRM0025 23-CAS0083 23-CAS0336 28-GRD00042 8- G R D 0 0 0 4 2 8- G R D 0 0 0 4 28-G R D 00042 8 - C A S 0 3 2 8 2 8 -G R D 0 0 0 4 28-GRD000428-GRD00042 8 -G R D 0 0 0 4 28-CAS03292 3-T B L 0 5 8 128-DPR007428-DPR00742 8 -T B L033 0 2 8-T B L 0 5 8 128-TB L054390-SCL007300-PCL000190-TBL035428-OVN0154 28-OVN015428-OVN01132 8-T B L 0 5 7 6 BOUNDARY BOUNDARYBOUNDARYBOUNDARYBOUNDARY BOUNDARYBOUNDARYBOUNDARY BOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARY BOUNDARYA A A.2 A.2 A.3 A.3 A.6 A.6 B B B.2 B.2 B.3 B.3 B.5 B.5 B.7 B.7 C C C.7 D D E E E.4 F F G G 6.9 H H 10 10 9 9 8 8 7 7 6.8 6.7 6 6 H.1 H.1G.5.3G.5.2 5 5 4.6 4.3 4.2 4 44.1 3.6 3.4 3.3 3 33.1 2.9 2.5 2.3 2 2 1.61.5 1.31.2 1 10.9 0.9 Y.4 Y.3 Y.2 Y.1 8.6 X.3 X.2 X Z.1W.1 7.8 6.5 B.9 C.3 C.5 C.6 D.1 D.5 D.8 E.3 E.6 E.7 F.1 F.2 F.3 F.5 F.6 F.7 F.8 G.1 G.4 G.5.1 G.5.4G.6 0 0 0.3 0.3 D D 1 2"ø DCWS 1 1/2"ø DWHS 3/4"ø DHWRC 2"ø DWHS 2"ø DCWS 3/4"ø DCWS 3/4"ø DWHS 3/4"ø DCWS 3/4"ø DWHS 20' - 0 1/4"145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road, Suite 200Rochester NY, 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.1/16"=1'-0"7/2/2019 2:55:01PMC:\Users\monom\Documents\071_Ithaca_PLUMB_CENTRAL_2017_monomCVV2R.rvtITHACAM508DOLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 ASTEY500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/2019 TBD DOMESTIC WATER SERVICE DEMO PLANNKEY PLAN N.T.S 10 5 3 1 B D F H M508D_3 M508D_2 M508D_4 M508D_1 OLD WORLD CHEESE REMODEL DEMO NOTES: REMOVE 3/4" HOT & COLD WATER DROPS TO SINK (SNK0050) FROM INDICATED DISCONNECT POINTS SAVE SINK & FIXTURES FOR RELOCATION.1 Revision Schedule # Date Revision 1 07/03/19 PERMIT SET PLM042 10-CAS039110-CAS039110-CAS039110-CAS039110-TBL060310-TBL060300-GRD0004 00-GRD0004 10-CAS0317 1 0 -C A S 0 2 9 8 00-GRD000400-GRD0004 00-GRD000400-GRD0004 10-CAS0298 10-SCL006710-SCL006710-TBL070400-GRD000400-GRD000400-GRD000400-GRD0004 00-GRD000400-GRD0004 00-GRD0004 00-GRD000400-GRD000400-GRD0004 00-GRD0004 00-GRD0004 00-GRD0004 00-GRD000410-TBL070410-TBL060310-TBL060310-TBL0464 10-TBL046410-TBL046410-TBL046410-TBL010010-TBL010010-TBL010010-WPR000210-CAB002710-CAB0027TBL0631 VIF WIDTH VIF DEPTH E E.4 F G 6.9 H 10 9 8 7 6.8 6.7 6 H.1G.5.3G.5.2 5 4.6 Y.4 Y.3 Y.2 Y.1 8.6 Z.1 3' - 0"3' - 0"5' - 0"8' - 0" 4' - 3" P P 1 3/4"ø DWHS3/4"ø DCWS 3/4"ø DWHS3/4"ø DCWS 2"ø DCWS 1 1/2"ø DWHS 3/4"ø DHWRC 2"ø DWHS 2"ø DCWS 20' - 0 1/4"145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.1/8"=1'-0"7/2/2019 3:11:14 PMC:\Users\monom\Documents\071_Ithaca_PLUMB_CENTRAL_2017_monomCVV2R.rvtITHACAM508_2OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 ASTEY500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/2019 TBD QUADRANT 2 DOMESTIC WATER SERVICE PLANN KEY PLAN N.T.S 5 3 1 B D F 10 H M508_3 M508_2 M508_4 M508_1 OLD WORLD CHEESE REMODEL INSTALLATION NOTES: PROVIDE NEW 3/4" HOT & COLD WATER DROPS TO RELOCATED SINK (SNK0050) FROM INDICATED CONNECTION POINTS REUSING PREVIOUSLY SAVED FIXTURES.1 Revision Schedule # Date Revision 1 07/03/19 PERMIT SET PLM042 C O F F E E B E A N C A BI N E T17-DPR003617-DPR003617-DPR00361 7- D P R 0 0 3 6 17-COFFEE ROASTER 17-CAB0805 17-CAB0978 17-CAB0984 17-CAB0805 17-CAB0852 17-CAB0806 1 7 -B I N 0 1 5 1 17-REF016717-REF0167 17-REF0167 17-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-CAB092817-DPR010717-DPR010717-DPR0107 17-REF016717-REF0112 17-OVN0107 17-OVN0103 17-DPR0130 17-RGS0004 17-DPR0128 17-DPR012017-REF0244 17-REF0219 17-CPA0035 17-GDR0008 17-GDR000817-SCL005817-GDR0008 17-COFFEE BEAN CABINET 17-COFFEEBEANCABINET 17-CAB0747 1 7- C O F F E E B E A N C A BI N E T 17-MXR002917-MXR002917-MXR0029 17-OVN010717-DPR003617-DPR003617-DPR0036 17-DPR003617-DPR003617-DPR0036 1 7- D P R 0 0 3 6 1 7- D P R 0 0 3 6 1 7-D P R 0 0 3 6 1 7- D P R 0 0 3 6 17-REF0285 17-GDR0026 17-WRM0065 17-TELEPHONE 17-BIN0024 17-GDR0027 17-SNK0253 17-SNK0508 17-CPA003910-CAS039110-CAS039110-CAS039110-CAS039110-TBL060310-TBL060300-GRD0004 00-GRD0004 10-CAS0317 1 0-CA S 02 9 8 00-GRD000400-GRD0004 00-GRD000400-GRD0004 10-CAS0298 03-CAS010403-CAS010407-CAS010507-CAS010507-CAS010507-CAS010507-CAS0206 00-GRD000600-GRD0006 07-STG023307-SCN0001 07-MNR0015 07-RGS0004 07-WKS019607-PNT001407-WKS019507-CAB037707-WKS023507-MED000107-FRZ006407-SHF0122 07-SHF012207-SHF0122 07-SHF0122 07-SHF012207-SHF0123 07-SHF0122 07-SHF0122 07-SHF0123 07-SHF012507-SHF012507-SHF012207-SHF012307-CAB057107-CAB057107-CAB036707-CAB036707-DPR010807-PNT001107-CAB036707-CAB036707-DPR01080 7 -MNR0 01 5 07-MNR001507-PNT001007-CAB036707-CAB036707-DPR010807-CAB036707-CAB036707-DPR010807-MNR00 1507-MNR001507-SNK015207-CAB034107-CAB010507-CAB017407-CAB010607-REF009607-CAB010607-CAB017407-CAB046007-CAB046107-CAB046107-MNR001507-CAB026607-CAB026607-CAB038407-CAB026607-CAB038407-CAB026607-MNR001507-PNT001407-MNR001507-SHF012207-SHF0123 07-WKS019607-WKS019607-WKS0196 07-CAB0378 07-SCN0001 07-MNR0015 07-RGS000407-CAB0378 07-SCN0001 07-MNR0015 07-RGS000407-CAB0378 07-SCN0001 07-MNR0015 07-RGS000407-MNR001507-PNT001407-WKS019507-MNR001507-CAB037707-PNT001407-CAB038407-WKS023507-MNR001507-PNT001407-MNR001507-CAB046307-CAB038407-STG0233 07-STG0233 10-SCL006710-SCL006710-TBL070407-DRG0009VIF WIDTH07-SHF020307-SHF0203 07-MNR001500-REF0242 00-GRD000400-GRD000400-GRD000400-GRD0004 00-GRD000400-GRD0004 00-GRD0004 00-GRD000400-GRD000400-GRD0004 00-GRD0004 00-GRD0004 00-GRD0004 00-GRD000410-TBL070410-TBL060310-TBL060310-TBL0464 10-TBL046410-TBL046410-TBL046410-TBL010010-TBL010010-TBL010010-WPR000210-CAB002710-CAB002707-SCN0001 07-SCN0001 07-SCN0001 07-SCN0001 07-CPA003507-CPA003507-CPA003507-CPA003507-CPA003507-PNT002407-PNT002407-PNT002407-PNT002407-PNT002407-RGS000407-STG023407-STG0234 07-STG023407-STG023407-STG023407-STG023407-STG023407-SCN001507-SCN001507-PNT001007-CPA003307-CPA003307-CPA003307-CPA003307-FAX 07-TELEPHONE07-TELEPHONE 07-TELEPHONE 07-WKS020924-STG010924-STG0109 24-STG010924-STG01092 4-S TG 0 10924 -S T G 01 0 9 2 4-S TG 0 10924-TBL0722 ADA 24-TBL0722 ADA 27-DIV007927-DIV007927-DIV007927-DIV007927-DIV0079 27-CPA0039 27-CPA0039 27-CPA0039 27-CPA003927-CPA0035 27-CPA0035 27-CPA0035 27-CPA003527-RGS000427-RGS000427-RGS000427-RGS000427-SCN0008 27-SCN0008 27-SCN0008 27-SCN000827-WKS039927-WKS0398 27-WKS039827-WKS040000-GRD000400-GRD0004 04-CAS0104 04-CAS0104 86-VND000486-TBL060086-SLC000986-TBL060086-SNK004886-REF016786-WRM005686-OVN011686-TBL069386-REF020186-TBL069386-REF020186-CAB085886-TBL032086-DPR009386-ICM004486-CAB002786-DSK0004 86-TBL006286-RKM015238-KTL001338-KTL001338-SCL0067 38-SCL006738-SHF0258 38-SHF0258 38-SHF0258 38-SHF0258 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 38-REF0124 38-REF0124 38-SHF025838-SHF025838-TBL035938-FDP0004 38-FDP0022 38-WPR0002 38-SHF022938-SHF0229 38-TBL048138-SNK0062CAB029938-SNK025538-TBL032038-OVN014638-RKM003238-RKM003238-RKM003238-CRT0007 38-CRT000438-CRT000438-CRT000438-CRT0004 38-RKM003238-RKM003238-CRT0007 38-RKM0032 38-RKM0032 38-SHF025838-SHF0258RKF0073RKF007338-SNK025338-CNV002938-TBL0631VIF WIDTHVIF DEPTHTBL0631 VIF WIDTH VIF DEPTH 18-CRT000418-CRT000488-WRM0025 23-CAS0083 23-CAS0336 28-GRD00042 8- G R D 0 0 0 4 2 8- G R D 0 0 0 4 28-G R D 00042 8 - C A S 0 3 2 8 2 8 -G R D 0 0 0 4 28-GRD000428-GRD00042 8 -G R D 0 0 0 4 28-CAS03292 3- T B L 0 5 8 128-DPR007428-DPR007428-TB L 0 3 302 8- T B L 0 5 8 128-T B L054390-SCL007300-PCL000190-TBL035428-OVN0154 28-OVN015428-OVN01132 8- T B L 0 5 7 6 BOUNDARY BOUNDARYBOUNDARYBOUNDARYBOUNDARY BOUNDARYBOUNDARYBOUNDARY BOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARY BOUNDARYA A A.2 A.2 A.3 A.3 A.6 A.6 B B B.2 B.2 B.3 B.3 B.5 B.5 B.7 B.7 C C C.7 D D E E E.4 F F G G 6.9 H H 10 10 9 9 8 8 7 7 6.8 6.7 6 6 H.1 H.1G.5.3G.5.2 5 5 4.6 4.3 4.2 4 44.1 3.6 3.4 3.3 3 33.1 2.9 2.5 2.3 2 2 1.61.5 1.31.2 1 10.9 0.9 Y.4 Y.3 Y.2 Y.1 8.6 X.3 X.2 X Z.1W.1 7.8 6.5 B.9 C.3 C.5 C.6 D.1 D.5 D.8 E.3 E.6 E.7 F.1 F.2 F.3 F.5 F.6 F.7 F.8 G.1 G.4 G.5.1 G.5.4G.6 0 0 0.3 0.33' - 0"3' - 0"5' - 0"8' - 0" 4' - 3" P P 1 3/4"ø DWHS3/4"ø DCWS 3/4"ø DWHS3/4"ø DCWS 2"ø DCWS 1 1/2"ø DWHS 3/4"ø DHWRC 2"ø DWHS 2"ø DCWS 20' - 0 1/4"145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road, Suite 200Rochester NY, 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.1/16"=1'-0"7/2/2019 2:53:22PMC:\Users\monom\Documents\071_Ithaca_PLUMB_CENTRAL_2017_monomCVV2R.rvtITHACAM508OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 ASTEY500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/2019 TBD DOMESTIC WATER SERVICE PLANNKEY PLAN N.T.S 10 5 3 1 B D F H M508_3 M508_2 M508_4 M508_1 OLD WORLD CHEESE REMODEL INSTALLATION NOTES: PROVIDE NEW 3/4" HOT & COLD WATER DROPS TO RELOCATED SINK (SNK0050) FROM INDICATED CONNECTION POINTS REUSING PREVIOUSLY SAVED FIXTURES.1 Revision Schedule # Date Revision 1 07/03/19 PERMIT SET PLM042 10-CAS0317 1 0 -C A S 0 2 9 8 00-GRD000400-GRD0004 00-GRD000400-GRD0004 10-CAS0298 10-SCL006710-SCL006710-WPR000210-CAB002710-CAB002710-TBL0464 10-CAS023910-TBL046410-TBL046410-TBL04641 0 -T B L 0 4 6 4 10-CAS0239 10-CAS023910-CAS0299TBL0631 VIF WIDTH VIF DEPTH 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO EXISTING 3" FD-1 11/2" COND. TO NEW 3" FD-1 PUMP P-1REFER TO PUMP SCHEDULE DWG. M500C 34 CO CO 3/4"COND. PIPE DN. TO FUNNEL 3/4" CO CO 3/4" 3/4" 1" 1" COND. PIPE DN. TO FS CO CO 1" COND. PIPE DN. TO FD-1 1-1/2" CONDENSATE 1-1/2" CONDENSATE 1-1/2" CONDENSATE CO 3/4"COND. PIPE DN. TO EXISTING FD CO CO 10" @ 2%8" RD 8" RD8" @ 1% 8" RD 8" RD 8" @ 1%8" RD10" @ 1% 8" @ 1%10" LEADER12" @ 2%10" @ 2%10" @ 1%SEE SITE DWG.FOR CONTINUATION21'-2" 14'-2"2'-0"4'-0"1'-6"CO CO 2" VENT UP 2"VENT UP 2" VENT UP 11/2" COND. DNTO FD. 11/2" COND. DR DNTO FD.(TYP. 3) 11/2" COND. DR DNTO FD. 11/2" COND. DNTO EXISTING FD. 2" VENT 11/2" PUMPDISCHARGE 2" VENT UP 11/2" COND. DNTO 3" FD-1. 3/4"3/4" 3/4" 11/2" COND. DN TO 3"FD. 11/2" COND. DN TO NEW 3"FD-1. 11/2" COND. DN TO 3"FD.LWA210DRAIN(-15-1/8")REFRLWA210DRAIN(-15-1/8")REFRE E.4 F G 6.9 H 10 9 8 7 6.8 6.7 6 H.1G.5.3G.5.2 5 4.6 Y.4 Y.3 Y.2 Y.1 8.6 Z.1 145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.1/8"=1'-0"7/2/2019 2:42:12 PMC:\Users\monom\Documents\071_Ithaca_PLUMB_CENTRAL_2017_monomCVV2R.rvtITHACAM506D_2OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 ASTEY500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/2019 TBD QUADRANT 2 ABOVE GRADE STORM, SANITARY AND VENT DEMO PLANN KEY PLAN N.T.S 5 3 1 B D F 10 H M506D_3 M506D_2 M506D_4 M506D_1 OLD WORLD CHEESE REMODEL DEMO NOTES: DISCONNECT DRAIN LINE FROM SINK (SNK0050) SAVE FOR SINK RELOCATION.1 1 Revision Schedule # Date Revision 1 07/03/19 PERMIT SET PLM042 C O F F E E B E A N C A BI N E T17-DPR003617-DPR003617-DPR00361 7- D P R 0 0 3 6 17-COFFEE ROASTER 17-CAB0805 17-CAB0978 17-CAB0984 17-CAB0805 17-CAB0852 17-CAB0806 1 7 -B I N 0 1 5 1 17-REF016717-REF0167 17-REF0167 17-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-CAB092817-DPR010717-DPR010717-DPR0107 17-REF016717-REF0112 17-OVN0107 17-OVN0103 17-DPR0130 17-RGS0004 17-DPR0128 17-DPR012017-REF0244 17-REF0219 17-CPA0035 17-GDR0008 17-GDR000817-SCL005817-GDR0008 17-COFFEE BEAN CABINET 17-COFFEEBEANCABINET 17-CAB0747 1 7- C O F F E E B E A N C A BI N E T 17-MXR002917-MXR002917-MXR0029 17-OVN010717-DPR003617-DPR003617-DPR0036 17-DPR003617-DPR003617-DPR0036 1 7- D P R 0 0 3 6 1 7- D P R 0 0 3 6 1 7-D P R 0 0 3 6 1 7- D P R 0 0 3 6 17-REF0285 17-GDR0026 17-WRM0065 17-TELEPHONE 17-BIN0024 17-GDR0027 17-SNK0253 17-SNK0508 17-CPA0039 10-CAS0317 1 0 -C A S 0 2 98 00-GRD000400-GRD0004 00-GRD000400-GRD0004 10-CAS0298 03-CAS010403-CAS010407-CAS010507-CAS010507-CAS010507-CAS010507-CAS0206 00-GRD000600-GRD0006 07-STG023307-SCN0001 07-MNR0015 07-RGS0004 07-WKS019607-PNT001407-WKS019507-CAB037707-WKS023507-MED000107-FRZ006407-SHF0122 07-SHF012207-SHF0122 07-SHF0122 07-SHF012207-SHF0123 07-SHF0122 07-SHF0122 07-SHF0123 07-SHF012507-SHF012507-SHF012207-SHF012307-CAB057107-CAB057107-CAB036707-CAB036707-DPR010807-PNT001107-CAB036707-CAB036707-DPR01080 7 -MNR0 01 5 07-MNR001507-PNT001007-CAB036707-CAB036707-DPR010807-CAB036707-CAB036707-DPR010807-MNR00 1507-MNR001507-SNK015207-CAB034107-CAB010507-CAB017407-CAB010607-REF009607-CAB010607-CAB017407-CAB046007-CAB046107-CAB046107-MNR001507-CAB026607-CAB026607-CAB038407-CAB026607-CAB038407-CAB026607-MNR001507-PNT001407-MNR001507-SHF012207-SHF0123 07-WKS019607-WKS019607-WKS0196 07-CAB0378 07-SCN0001 07-MNR0015 07-RGS000407-CAB0378 07-SCN0001 07-MNR0015 07-RGS000407-CAB0378 07-SCN0001 07-MNR0015 07-RGS000407-MNR001507-PNT001407-WKS019507-MNR001507-CAB037707-PNT001407-CAB038407-WKS023507-MNR001507-PNT001407-MNR001507-CAB046307-CAB038407-STG0233 07-STG0233 10-SCL006710-SCL006710-WPR000210-CAB002710-CAB002707-DRG0009VIF WIDTH07-SHF020307-SHF0203 07-MNR001500-REF0242 10-TBL0464 10-CAS023910-TBL046410-TBL046410-TBL04641 0 -T B L 0 4 6 4 10-CAS0239 10-CAS023910-CAS029907-SCN0001 07-SCN0001 07-SCN0001 07-SCN0001 07-CPA003507-CPA003507-CPA003507-CPA003507-CPA003507-PNT002407-PNT002407-PNT002407-PNT002407-PNT002407-RGS000407-STG023407-STG0234 07-STG023407-STG023407-STG023407-STG023407-STG023407-SCN001507-SCN001507-PNT001007-CPA003307-CPA003307-CPA003307-CPA003307-FAX 07-TELEPHONE07-TELEPHONE 07-TELEPHONE 07-WKS020924-STG010924-STG0109 24-STG010924-STG01092 4-S TG 0 10924 -S T G 01 0 9 2 4-S TG 0 10924-TBL0722 ADA 24-TBL0722 ADA 27-DIV0079 27-DIV0079 27-DIV0079 27-DIV0079 27-DIV0079 27-CPA0039 27-CPA0039 27-CPA0039 27-CPA003927-CPA0035 27-CPA0035 27-CPA0035 27-CPA003527-RGS000427-RGS000427-RGS000427-RGS000427-SCN0008 27-SCN000827-SCN000827-SCN000827-WKS039927-WKS0398 27-WKS0398 27-WKS040000-GRD000400-GRD0004 04-CAS0104 04-CAS0104 86-VND000486-TBL060086-SLC000986-TBL060086-SNK004886-REF016786-WRM005686-OVN011686-TBL069386-REF020186-TBL069386-REF020186-CAB085886-TBL032086-DPR009386-ICM004486-CAB002786-DSK0004 86-TBL006286-RKM015238-KTL001338-KTL001338-SCL0067 38-SCL006738-SHF0258 38-SHF0258 38-SHF0258 38-SHF0258 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 38-REF0124 38-REF0124 38-SHF0258 38-SHF025838-TBL035938-FDP0004 38-FDP0022 38-WPR0002 38-SHF022938-SHF0229 38-TBL048138-SNK0062CAB029938-SNK025538-TBL032038-OVN014638-RKM003238-RKM003238-RKM003238-CRT0007 38-CRT000438-CRT000438-CRT000438-CRT0004 38-RKM003238-RKM003238-CRT0007 38-RKM0032 38-RKM0032 38-SHF0258 38-SHF0258RKF0073 RKF007338-SNK025338-CNV002938-TBL0631VIF WIDTHVIF DEPTHTBL0631 VIF WIDTH VIF DEPTH 18-CRT000418-CRT000488-WRM0025 23-CAS0083 23-CAS0336 28-GRD00042 8- G R D 0 0 0 4 2 8- G R D 0 0 0 4 28-G R D 00042 8 - C A S 0 3 2 8 2 8 -G R D 0 0 0 4 28-GRD000428-GRD00042 8 -G R D 0 0 0 4 28-CAS03292 3- T B L 0 5 8 128-DPR007428-DPR007428-TB L 0 3 302 8- T B L 0 5 8 128-T B L054390-SCL007300-PCL000190-TBL035428-OVN0154 28-OVN015428-OVN01132 8- T B L 0 5 7 6 P 42 42 42 42 43 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO EXISTING 3" FD-1 11/2" COND. TO NEW 3" FD-1 9 PUMP P-1REFER TO PUMP SCHEDULE DWG. M500C 2" WPCO 11/4" WASTE EXIST 3" HUB DN 2" VENT UP EXIST 3" HUB DN 2" VENT RISE 2" WPCO WPCO WPCOEXIST 3" HUB DN 2" VENT UP 3/4" 3/4" 30 30 32 29 31 34 24 25 26 27 CO 3/4" COND. PIPE DN. TO FD-5 CO 3/4"COND. PIPE DN. TO FUNNEL 3/4" 3/4" CO 3/4" COND. PIPE DN. TO FD 3/4" CO CO 3/4" 3/4" 1" 1" COND. PIPE DN. TO FS CO CO 1" COND. PIPE DN. TO FD-1 1-1/2" CONDENSATE 1-1/2" CONDENSATE 1-1/2" CONDENSATE CO 3/4"COND. PIPE DN. TO EXISTING FD CO CO CO CO 2'-0" 3'-6"2'-0"8" @ 1% 10" @ 1%10" @ 2%8" RD 10" LEADER12" @ 1%SEE SITE DWG.FOR CONTINUATION8" RD 8" RD 8" RD 10" @ 1%8" RD 10" @ 1% 10" @ 2%12" @ 2%10" LEADER 8" RD8" @ 1% 8" RD 8" RD 8" @ 1%8" RD10" @ 1% 8" @ 1%10" LEADER12" @ 2%10" @ 2%10" @ 2%10" @ 1%SEE SITE DWG.FOR CONTINUATIONSEE SITE DWG.FOR CONTINUATION21'-2" 14'-2"2'-0"4'-0"1'-6"3'-0" CO CO CO CO CO CO CO CO CO CO CO CO 3/4" COND.FROM DPROO93 TO PUMP VENT UP TO EXISTING VENT PIPING 3/4" PUMP DISCHARGE INSIDE WALL TO NEW FLOOR DRAIN 3" FD-5 TERMINATE WITH AIR GAP.3/4" PUMP DISCHARGE UP INSIDE WALL. PUMP P-2 3/4" PUMP DISCHARGE ABOVE CEILING. CO CO CO CO CO CO CO CO CO 3/4" 3/4" 3/4" 3/4" 1" 1" COND. DN TO EXISTING FD 3/4" 3/4" CO CO CO CO CO 3/4" COND. DN TO EXISTING FD CO CO CO CO CO 3/4"COND. PIPE DN. TO EXISTING DISCHARGE IN WALL 3/4" 3/4" 3/4"3/4"3/4"2" VENT UP 2" VENT UP 2" VENT UP 2"VENT UP 2" VENT UP 2" VENT UP 1-1/2" COND. DR DNTO FD. CO 1" 1" 11/2" COND. DR DN TO FD. 11/2" COND. DNTO FD. 11/2" COND. DR DNTO FD. 11/2" COND. DR DNTO FD.(TYP. 3) 11/2" COND. DR DNTO FD. 11/2" COND. DN TO 3"FD. 11/2" COND. DNTO FD. 11/2" COND. DNTO 3"FD-1. 11/2" COND. DNTO 3"FD-1. 11/2" COND. DNTO EXISTING FD. 11/2"COND. DNTO EXISTING FD. 11/2" COND. DNTO EXISTING FD. 11/2" COND. DNTO FD. 11/2" COND. DNTO 3" FD-1. 11/2" COND. DNTO 3" FD-1. 11/2" COND. DNTO EXISTING FD. 11/2" COND. DNTO 3"FD-1. CO 3/4" 3/4" WASTE DNTO EXISTING 3"FD 2" VENT 11/2" PUMPDISCHARGE 2" VENT UP 11/2" COND. DNTO 3" FD-1. 1-1/2" 1-1/2" COND. DR DNTO 3"FD-1 11/2" COND. DNTO 3"FD-1.CO 3/4" 3/4" WASTE DNTO EXISTING 3"FD 3/4"3/4" 3/4" 11/2" COND. DN TO 3"FD. CO 3/4" WASTE DNTO EXISTING 3" FD 11/2" COND. DN TO NEW 3"FD-1. 11/2" COND. DN TO 3"FD. 11/2" COND. DN TO NEW 3"FD-1. 11/2" COND. DN TO 3"FD. 11/2" COND. DN TO NEW 3"FD-1. 11/2" COND. DN TO 3"FD. 11/2" COND. DN TO NEW 3"FD-1. 2" VENT UP, CONNECT TO EXISTING VENT SYSTEM 1-1/4" WASTE DN TO EXISTING 3"FD PROVIDE 1 1/2" WASTE PIPE FROM SINK (SNK0487) TO HUB IN WALL. 11/2" COND. DN TO 3"FD-1.LWA210DRAIN(-15-1/8")REFRLWA210DRAIN(-15-1/8")REFRMLG4-330DRAIN(-25")REFRMLG4-330DRAIN(-25")REFRLWA155DR A I N (-15- 1 /8" ) REF R BOUNDARY BOUNDARYBOUNDARYBOUNDARYBOUNDARY BOUNDARYBOUNDARYBOUNDARY BOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARY BOUNDARYA A A.2 A.2 A.3 A.3 A.6 A.6 B B B.2 B.2 B.3 B.3 B.5 B.5 B.7 B.7 C C C.7 D D E E E.4 F F G G 6.9 H H 10 10 9 9 8 8 7 7 6.8 6.7 6 6 H.1 H.1G.5.3G.5.2 5 5 4.6 4.3 4.2 4 44.1 3.6 3.4 3.3 3 33.1 2.9 2.5 2.3 2 2 1.61.5 1.31.2 1 10.9 0.9 Y.4 Y.3 Y.2 Y.1 8.6 X.3 X.2 X Z.1W.1 7.8 6.5 B.9 C.3 C.5 C.6 D.1 D.5 D.8 E.3 E.6 E.7 F.1 F.2 F.3 F.5 F.6 F.7 F.8 G.1 G.4 G.5.1 G.5.4G.6 0 0 0.3 0.3 145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road, Suite 200Rochester NY, 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.1/16"=1'-0"7/2/2019 2:53:16PMC:\Users\monom\Documents\071_Ithaca_PLUMB_CENTRAL_2017_monomCVV2R.rvtITHACAM506DOLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 ASTEY500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/2019 TBD ABOVE GRADE STORM, SANITARY AND VENT DEMO PLANNKEY PLAN N.T.S 10 5 3 1 B D F H M506D_3 M506D_2 M506D_4 M506D_1 1 OLD WORLD CHEESE REMODEL DEMO NOTES: DISCONNECT DRAIN LINE FROM SINK (SNK0050) SAVE FOR SINK RELOCATION.1 Revision Schedule # Date Revision 1 07/03/19 PERMIT SET PLM042 10-CAS039110-CAS039110-CAS039110-CAS039110-TBL060310-TBL060300-GRD0004 00-GRD0004 10-CAS0317 1 0 -C A S 0 2 9 8 00-GRD000400-GRD0004 00-GRD000400-GRD0004 10-CAS0298 10-SCL006710-SCL006710-TBL070400-GRD000400-GRD000400-GRD000400-GRD0004 00-GRD000400-GRD0004 00-GRD0004 00-GRD000400-GRD000400-GRD0004 00-GRD0004 00-GRD0004 00-GRD0004 00-GRD000410-TBL070410-TBL060310-TBL060310-TBL0464 10-TBL046410-TBL046410-TBL046410-TBL010010-TBL010010-TBL010010-WPR000210-CAB002710-CAB0027TBL0631 VIF WIDTH VIF DEPTH 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO EXISTING 3" FD-1 11/2" COND. TO NEW 3" FD-1 PUMP P-1REFER TO PUMP SCHEDULE DWG. M500C 34 CO CO 3/4"COND. PIPE DN. TO FUNNEL 3/4" CO CO 3/4" 3/4" 1" 1" COND. PIPE DN. TO FS CO CO 1" COND. PIPE DN. TO FD-1 1-1/2" CONDENSATE 1-1/2" CONDENSATE 1-1/2" CONDENSATE CO 3/4"COND. PIPE DN. TO EXISTING FD CO CO 10" @ 2%8" RD 8" RD8" @ 1% 8" RD 8" RD 8" @ 1%8" RD10" @ 1% 8" @ 1%10" LEADER12" @ 2%10" @ 2%10" @ 1%SEE SITE DWG.FOR CONTINUATION21'-2" 14'-2"2'-0"4'-0"1'-6"CO CO 2" VENT UP 2"VENT UP 2" VENT UP 11/2" COND. DNTO FD. 11/2" COND. DR DNTO FD.(TYP. 3) 11/2" COND. DR DNTO FD. 11/2" COND. DNTO EXISTING FD. 2" VENT 11/2" PUMPDISCHARGE 2" VENT UP 11/2" COND. DNTO 3" FD-1. 3/4"3/4" 3/4" 11/2" COND. DN TO 3"FD. 11/2" COND. DN TO NEW 3"FD-1. 11/2" COND. DN TO 3"FD.LWA210DRAIN(-15-1/8")REFRLWA210DRAIN(-15-1/8")REFRE E.4 F G 6.9 H 10 9 8 7 6.8 6.7 6 H.1G.5.3G.5.2 5 4.6 Y.4 Y.3 Y.2 Y.1 8.6 Z.1 3' - 0"3' - 0"5' - 0"8' - 0" 4' - 3" 1 1/2" CD TO 3"FD-1 1 1/2" CD TO 3"FD-1 1 1/2" CD TO 3"FD-1 1 1/2" CD TO 3"FD-14"DPCO 4"DPCO 4"DPCO 145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.1/8"=1'-0"7/2/2019 2:42:11 PMC:\Users\monom\Documents\071_Ithaca_PLUMB_CENTRAL_2017_monomCVV2R.rvtITHACAM506_2OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 ASTEY500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/2019 TBD QUADRANT 2 ABOVE GRADE STORM, SANITARY AND VENT PLANN KEY PLAN N.T.S 5 3 1 B D F 10 H M506_3 M506_2 M506_4 M506_1 OLD WORLD CHEESE REMODEL INSTALLATION NOTES: PROVIDE 1 1/2" CONDENSATE DRAIN PIPING FROM CASES TO NEW FLOOR DRAINS.1 1 1 1 1 Revision Schedule # Date Revision 1 07/03/19 PERMIT SET PLM042 C O F F E E B E A N C A BI N E T17-DPR003617-DPR003617-DPR00361 7-D P R 0 0 3 6 17-COFFEE ROASTER 17-CAB0805 17-CAB0978 17-CAB0984 17-CAB0805 17-CAB0852 17-CAB0806 1 7 -B IN 0 1 5 1 17-REF016717-REF0167 17-REF0167 17-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-CAB092817-DPR010717-DPR010717-DPR0107 17-REF016717-REF0112 17-OVN0107 17-OVN0103 17-DPR0130 17-RGS0004 17-DPR0128 17-DPR012017-REF0244 17-REF0219 17-CPA0035 17-GDR0008 17-GDR000817-SCL005817-GDR0008 17-COFFEE BEAN CABINET 17-COFFEEBEANCABINET 17-CAB0747 1 7-C O F F E E B E A N C A BI N E T 17-MXR002917-MXR002917-MXR0029 17-OVN010717-DPR003617-DPR003617-DPR0036 17-DPR003617-DPR003617-DPR0036 1 7- D P R 0 0 3 6 1 7- D P R 0 0 3 6 1 7-D P R 0 0 3 6 1 7-D P R 0 0 3 6 17-REF0285 17-GDR0026 17-WRM0065 17-TELEPHONE 17-BIN0024 17-GDR0027 17-SNK0253 17-SNK0508 17-CPA003910-CAS039110-CAS039110-CAS039110-CAS039110-TBL060310-TBL060300-GRD0004 00-GRD0004 10-CAS0317 1 0 -C A S 0 2 98 00-GRD000400-GRD0004 00-GRD000400-GRD0004 10-CAS0298 03-CAS010403-CAS010407-CAS010507-CAS010507-CAS010507-CAS010507-CAS0206 00-GRD000600-GRD0006 07-STG023307-SCN0001 07-MNR0015 07-RGS0004 07-WKS019607-PNT001407-WKS019507-CAB037707-WKS023507-MED000107-FRZ006407-SHF0122 07-SHF012207-SHF0122 07-SHF0122 07-SHF012207-SHF0123 07-SHF0122 07-SHF0122 07-SHF0123 07-SHF012507-SHF012507-SHF012207-SHF012307-CAB057107-CAB057107-CAB036707-CAB036707-DPR010807-PNT001107-CAB036707-CAB036707-DPR01080 7 -MNR0 01 5 07-MNR001507-PNT001007-CAB036707-CAB036707-DPR010807-CAB036707-CAB036707-DPR010807-MNR00 1507-MNR001507-SNK015207-CAB034107-CAB010507-CAB017407-CAB010607-REF009607-CAB010607-CAB017407-CAB046007-CAB046107-CAB046107-MNR001507-CAB026607-CAB026607-CAB038407-CAB026607-CAB038407-CAB026607-MNR001507-PNT001407-MNR001507-SHF012207-SHF0123 07-WKS019607-WKS019607-WKS0196 07-CAB0378 07-SCN0001 07-MNR0015 07-RGS000407-CAB0378 07-SCN0001 07-MNR0015 07-RGS000407-CAB0378 07-SCN0001 07-MNR0015 07-RGS000407-MNR001507-PNT001407-WKS019507-MNR001507-CAB037707-PNT001407-CAB038407-WKS023507-MNR001507-PNT001407-MNR001507-CAB046307-CAB038407-STG0233 07-STG0233 10-SCL006710-SCL006710-TBL070407-DRG0009VIF WIDTH07-SHF020307-SHF0203 07-MNR001500-REF0242 00-GRD000400-GRD000400-GRD000400-GRD0004 00-GRD000400-GRD0004 00-GRD0004 00-GRD000400-GRD000400-GRD0004 00-GRD0004 00-GRD0004 00-GRD0004 00-GRD000410-TBL070410-TBL060310-TBL060310-TBL0464 10-TBL046410-TBL046410-TBL046410-TBL010010-TBL010010-TBL010010-WPR000210-CAB002710-CAB002707-SCN0001 07-SCN0001 07-SCN0001 07-SCN0001 07-CPA003507-CPA003507-CPA003507-CPA003507-CPA003507-PNT002407-PNT002407-PNT002407-PNT002407-PNT002407-RGS000407-STG023407-STG0234 07-STG023407-STG023407-STG023407-STG023407-STG023407-SCN001507-SCN001507-PNT001007-CPA003307-CPA003307-CPA003307-CPA003307-FAX 07-TELEPHONE07-TELEPHONE 07-TELEPHONE 07-WKS020924-STG010924-STG0109 24-STG010924-STG010924 -S T G 01 0 9 24 -S T G 01 0 9 2 4-S TG 0 10924-TBL0722 ADA 24-TBL0722 ADA 27-DIV007927-DIV007927-DIV007927-DIV007927-DIV0079 27-CPA0039 27-CPA0039 27-CPA0039 27-CPA003927-CPA0035 27-CPA0035 27-CPA0035 27-CPA003527-RGS000427-RGS000427-RGS000427-RGS000427-SCN0008 27-SCN0008 27-SCN0008 27-SCN000827-WKS039927-WKS0398 27-WKS0398 27-WKS040000-GRD000400-GRD0004 04-CAS0104 04-CAS0104 86-VND000486-TBL060086-SLC000986-TBL060086-SNK004886-REF016786-WRM005686-OVN011686-TBL069386-REF020186-TBL069386-REF020186-CAB085886-TBL032086-DPR009386-ICM004486-CAB002786-DSK0004 86-TBL006286-RKM015238-KTL001338-KTL001338-SCL0067 38-SCL006738-SHF0258 38-SHF0258 38-SHF0258 38-SHF0258 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 38-REF0124 38-REF0124 38-SHF025838-SHF025838-TBL035938-FDP0004 38-FDP0022 38-WPR0002 38-SHF022938-SHF0229 38-TBL048138-SNK0062CAB029938-SNK025538-TBL032038-OVN014638-RKM003238-RKM003238-RKM003238-CRT0007 38-CRT000438-CRT000438-CRT000438-CRT0004 38-RKM003238-RKM003238-CRT0007 38-RKM0032 38-RKM0032 38-SHF025838-SHF0258RKF0073RKF007338-SNK025338-CNV002938-TBL0631VIF WIDTHVIF DEPTHTBL0631 VIF WIDTH VIF DEPTH 18-CRT000418-CRT000488-WRM0025 23-CAS0083 23-CAS0336 28-GRD00042 8- G R D 0 0 0 4 2 8- G R D 0 0 0 4 28-G R D 00042 8 - C A S 0 3 2 8 2 8 -G R D 0 0 0 4 28-GRD000428-GRD00042 8 -G R D 0 0 0 4 28-CAS03292 3-T B L 0 5 8 128-DPR007428-DPR00742 8 -T B L033 0 2 8- T B L 0 5 8 128-TB L054390-SCL007300-PCL000190-TBL035428-OVN0154 28-OVN015428-OVN01132 8- T B L 0 5 7 6 P 42 42 42 42 43 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO EXISTING 3" FD 11/2" COND. TO NEW 3" FD-1 11/2" COND. TO EXISTING 3" FD-1 11/2" COND. TO NEW 3" FD-1 9 PUMP P-1REFER TO PUMP SCHEDULE DWG. M500C 2" WPCO 11/4" WASTE EXIST 3" HUB DN 2" VENT UP EXIST 3" HUB DN 2" VENT RISE 2" WPCO WPCO WPCOEXIST 3" HUB DN 2" VENT UP 3/4" 3/4" 30 30 32 29 31 34 24 25 26 27 CO 3/4" COND. PIPE DN. TO FD-5 CO 3/4"COND. PIPE DN. TO FUNNEL 3/4" 3/4" CO 3/4" COND. PIPE DN. TO FD 3/4" CO CO 3/4" 3/4" 1" 1" COND. PIPE DN. TO FS CO CO 1" COND. PIPE DN. TO FD-1 1-1/2" CONDENSATE 1-1/2" CONDENSATE 1-1/2" CONDENSATE CO 3/4"COND. PIPE DN. TO EXISTING FD CO CO CO CO 2'-0" 3'-6"2'-0"8" @ 1% 10" @ 1%10" @ 2%8" RD 10" LEADER12" @ 1%SEE SITE DWG.FOR CONTINUATION8" RD 8" RD 8" RD 10" @ 1%8" RD 10" @ 1% 10" @ 2%12" @ 2%10" LEADER 8" RD8" @ 1% 8" RD 8" RD 8" @ 1%8" RD10" @ 1% 8" @ 1%10" LEADER12" @ 2%10" @ 2%10" @ 2%10" @ 1%SEE SITE DWG.FOR CONTINUATIONSEE SITE DWG.FOR CONTINUATION21'-2" 14'-2"2'-0"4'-0"1'-6"3'-0" CO CO CO CO CO CO CO CO CO CO CO CO 3/4" COND.FROM DPROO93 TO PUMP VENT UP TO EXISTING VENT PIPING 3/4" PUMP DISCHARGE INSIDE WALLTO NEW FLOOR DRAIN 3" FD-5 TERMINATE WITH AIR GAP.3/4" PUMP DISCHARGE UP INSIDE WALL. PUMP P-2 3/4" PUMP DISCHARGE ABOVE CEILING. CO CO CO CO CO CO CO CO CO 3/4" 3/4" 3/4" 3/4" 1" 1" COND. DN TO EXISTING FD 3/4" 3/4" CO CO CO CO CO 3/4" COND. DN TO EXISTING FD CO CO CO CO CO 3/4"COND. PIPE DN. TO EXISTING DISCHARGE IN WALL 3/4" 3/4" 3/4"3/4"3/4"2" VENT UP 2" VENT UP 2" VENT UP 2"VENT UP 2" VENT UP 2" VENT UP 1-1/2" COND. DR DNTO FD. CO 1" 1" 11/2" COND. DR DN TO FD. 11/2" COND. DNTO FD. 11/2" COND. DR DNTO FD. 11/2" COND. DR DNTO FD.(TYP. 3) 11/2" COND. DR DNTO FD. 11/2" COND. DN TO 3"FD. 11/2" COND. DNTO FD. 11/2" COND. DNTO 3"FD-1. 11/2" COND. DNTO 3"FD-1. 11/2" COND. DNTO EXISTING FD. 11/2"COND. DNTO EXISTING FD. 11/2" COND. DNTO EXISTING FD. 11/2" COND. DNTO FD. 11/2" COND. DNTO 3" FD-1. 11/2" COND. DNTO 3" FD-1. 11/2" COND. DNTO EXISTING FD. 11/2" COND. DNTO 3"FD-1. CO 3/4" 3/4" WASTE DNTO EXISTING 3"FD 2" VENT 11/2" PUMPDISCHARGE 2" VENT UP 11/2" COND. DNTO 3" FD-1. 1-1/2" 1-1/2" COND. DR DNTO 3"FD-1 11/2" COND. DNTO 3"FD-1.CO 3/4" 3/4" WASTE DNTO EXISTING 3"FD 3/4"3/4" 3/4" 11/2" COND. DN TO 3"FD. CO 3/4" WASTE DNTO EXISTING 3" FD 11/2" COND. DN TO NEW 3"FD-1. 11/2" COND. DN TO 3"FD. 11/2" COND. DN TO NEW 3"FD-1. 11/2" COND. DN TO 3"FD. 11/2" COND. DN TO NEW 3"FD-1. 11/2" COND. DN TO 3"FD. 11/2" COND. DN TO NEW 3"FD-1. 2" VENT UP, CONNECT TO EXISTING VENT SYSTEM 1-1/4" WASTE DN TO EXISTING 3"FD PROVIDE 1 1/2" WASTE PIPE FROM SINK (SNK0487) TO HUB IN WALL. 11/2" COND. DN TO 3"FD-1.LWA210DRAIN(-15-1/8")REFRLWA210DRAIN(-15-1/8")REFRMLG4-330DRAIN(-25")REFRMLG4-330DRAIN(-25")REFRLWA155DRAIN(-15-1/ 8 ")REFR BOUNDARY BOUNDARYBOUNDARYBOUNDARYBOUNDARY BOUNDARYBOUNDARYBOUNDARY BOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARY BOUNDARYA A A.2 A.2 A.3 A.3 A.6 A.6 B B B.2 B.2 B.3 B.3 B.5 B.5 B.7 B.7 C C C.7 D D E E E.4 F F G G 6.9 H H 10 10 9 9 8 8 7 7 6.8 6.7 6 6 H.1 H.1G.5.3G.5.2 5 5 4.6 4.3 4.2 4 44.1 3.6 3.4 3.3 3 33.1 2.9 2.5 2.3 2 2 1.61.5 1.31.2 1 10.9 0.9 Y.4 Y.3 Y.2 Y.1 8.6 X.3 X.2 X Z.1W.1 7.8 6.5 B.9 C.3 C.5 C.6 D.1 D.5 D.8 E.3 E.6 E.7 F.1 F.2 F.3 F.5 F.6 F.7 F.8 G.1 G.4 G.5.1 G.5.4G.6 0 0 0.3 0.33' - 0"3' - 0"5' - 0"8' - 0" 4' - 3" 1 1/2" CD TO 3"FD-1 1 1/2" CD TO 3"FD-1 1 1/2" CD TO 3"FD-1 1 1/2" CD TO 3"FD-14"DPCO 4"DPCO 4"DPCO 145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road, Suite 200Rochester NY, 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.1/16"=1'-0"7/2/2019 2:53:10PMC:\Users\monom\Documents\071_Ithaca_PLUMB_CENTRAL_2017_monomCVV2R.rvtITHACAM506OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 ASTEY500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/2019 TBD ABOVE GRADE STORM, SANITARY AND VENT PLANNKEY PLAN N.T.S 10 5 3 1 B D F H M506_3 M506_2 M506_4 M506_1 Revision Schedule # Date Revision 1 07/03/19 PERMIT SET PLM042 10-CAS039110-CAS039110-CAS039110-CAS039110-TBL060310-TBL060300-GRD0004 00-GRD0004 10-CAS0317 1 0 -C A S 0 2 9 8 00-GRD000400-GRD0004 00-GRD000400-GRD0004 10-CAS0298 10-TBL070400-GRD000400-GRD000400-GRD000400-GRD0004 00-GRD000400-GRD0004 00-GRD0004 00-GRD000400-GRD000400-GRD0004 00-GRD0004 00-GRD0004 00-GRD0004 00-GRD000410-TBL070410-TBL060310-TBL060310-TBL0464 10-TBL046410-TBL046410-TBL046410-TBL010010-TBL010010-TBL010010-WPR000210-CAB002710-CAB0027E E.4 F 6 53' - 0"3' - 0"5' - 0"8' - 0"0' - 6"0' - 1"5' - 5"4' - 5"0' - 7"5' - 2"5' - 1"2' - 5"5' - 5"2' - 7"5' - 4"7' - 3" P 3" FD-1 3" FD-1 3" FD-1 3" FD-1 1' - 5"4" DPCO 4" DPCO 4" DPCO -2' - 8 3/4" -2' - 2 1/4" -2' - 1 1/4" -2' - 2 3/4" 3" FUNNEL DRAIN 3"ø 3"ø 3"ø 3"ø 3"ø4"ø GR4"ø GR4"ø GR 4"ø GR145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.1/8"=1'-0"7/2/2019 2:42:09 PMC:\Users\monom\Documents\071_Ithaca_PLUMB_CENTRAL_2017_monomCVV2R.rvtITHACAM501_6OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 ASTEY500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/2019 TBD QUADRANT 6 BELOW GRADE STORM, SANITARY AND VENT PLAN10 5 3 1 B D F H KEY PLAN N.T.S N M501_4 M501_1 M501_2 M501_3 M501_5 M501_8 M501_7 M501_6 M501_12 M501_9 M501_10 M501_11 M501_13 M501_16 M501_15 M501_14 OLD WORLD CHEESE REMODEL INSTALLATION NOTES: PROVIDE UNDERGROUND PIPING AND CONNECT TO EXISTING AS SHOWN. FIELD VERIFY EXACT ROUTING OF PIPING AND INVERTS. PROVIDE 3" FD-1 FLOOR DRAINS, J.R.SMITH MODEL 2005-Y, NO HUB, DUCO COATED CAST IRON BODY, BOTTOM OUTLET, POLISHED BRONZE TOP, STRAINER DIAMETER-6", ADJUSTABLE. 1 2 Revision Schedule # Date Revision 1 07/03/19 PERMIT SET PLM042 C O F FEE B E A N C A BIN E T 17-COFFEEROASTER 17-CAB0805 17-CAB0978 17-CAB0984 17-CAB0805 17-CAB0852 17-CAB0806 1 7-B IN01 51 17-REF016717-REF0167 17-REF0167 17-CAB092817-REF0167 17-REF0112 17-REF0244 17-REF0219 17-COFFEE BEANCABINET 17-COFFEEBEANCABINET 17-CAB0747 17-C O F F E E B E A N C A BIN E T 17-REF0285 17-BIN002417-SNK0253 17-SNK050810-CAS039110-CAS039110-CAS039110-CAS039110-TBL060310-TBL060300-GRD0004 00-GRD0004 10-CAS0317 10-CAS0298 00-GRD000400-GRD0004 00-GRD000400-GRD0004 10-CAS0298 03-CAS010403-CAS010407-CAS010507-CAS010507-CAS010507-CAS010507-CAS0206 00-GRD000600-GRD0006 07-STG023307-WKS019607-WKS019507-WKS023507-MED000107-FRZ006407-SHF0122 07-SHF012207-SHF0122 07-SHF0122 07-SHF012207-SHF0123 07-SHF0122 07-SHF0122 07-SHF0123 07-SHF012507-SHF012507-SHF012207-SHF012307-CAB057107-CAB057107-CAB036707-CAB036707-CAB036707-CAB036707-PNT001007-CAB0367 07-CAB036707-CAB036707-CAB036707-SNK015207-CAB017407-CAB010607-REF009607-CAB010607-CAB017407-CAB046007-CAB046107-CAB046107-CAB026607-CAB026607-CAB038407-CAB026607-CAB038407-CAB026607-PNT001407-SHF012207-SHF0123 07-WKS019607-WKS019607-WKS0196 07-CAB0378 07-CAB0378 07-CAB037807-WKS019507-WKS023507-STG0233 07-STG0233 10-TBL070407-DRG0009VIF WIDTH07-SHF020307-SHF0203 00-REF0242 00-GRD000400-GRD000400-GRD000400-GRD0004 00-GRD000400-GRD0004 00-GRD0004 00-GRD000400-GRD000400-GRD0004 00-GRD0004 00-GRD0004 00-GRD0004 00-GRD000410-TBL070410-TBL060310-TBL060310-TBL0464 10-TBL046410-TBL046410-TBL046410-TBL010010-TBL010010-TBL010010-WPR000210-CAB002710-CAB002707-STG023407-STG0234 07-STG023407-STG023407-STG023407-STG023407-STG023407-WKS020924-STG010924-STG0109 24-STG010924-STG01092 4-S T G 0 10 9 2 4 -ST G0 10 9 2 4-S T G 0 10 9 24-TBL0722 ADA 24-TBL0722 ADA 27-DIV007927-DIV007927-DIV007927-DIV007927-DIV0079 27-CPA0039 27-CPA0039 27-CPA0039 27-CPA003927-CPA003527-CPA003527-CPA003527-CPA003527-RGS000427-RGS000427-RGS000427-RGS000427-SCN000827-SCN000827-SCN000827-SCN000827-WKS039927-WKS0398 27-WKS0398 27-WKS040000-GRD000400-GRD0004 04-CAS0104 04-CAS0104 86-VND000486-TBL060086-SLC000986-TBL060086-SNK004886-REF016786-WRM005686-OVN011686-TBL0693 86-REF020186-TBL0693 86-REF020186-CAB085886-TBL032086-DPR009386-ICM004486-CAB002786-DSK000486-TBL006286-RKM015238-KTL001338-KTL001338-SCL0067 38-SCL0067 38-SHF0258 38-SHF0258 38-SHF0258 38-SHF0258 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 38-REF0124 38-REF0124 38-SHF025838-SHF025838-TBL035938-FDP0004 38-FDP0022 38-WPR0002 38-SHF022938-SHF0229 38-TBL048138-SNK0062CAB029938-SNK025538-TBL032038-OVN014638-RKM003238-RKM003238-RKM003238-CRT0007 38-CRT000438-CRT000438-CRT000438-CRT0004 38-RKM003238-RKM003238-CRT0007 38-RKM0032 38-RKM0032 38-SHF025838-SHF0258RKF0073RKF007338-SNK025338-CNV002938-TBL0631VIF WIDTHVIF DEPTHTBL0631 VIF WIDTH VIF DEPTH 18-CRT000418-CRT000488-WRM0025 23-CAS0083 23-CAS0336 28-GRD000428-GRD000428-GRD00042 8-G R D 0 0 0 4 2 8- C A S 0 3 2 8 2 8-G RD0 00 4 2 8-GRD00 04 2 8-GRD00 04 2 8-GR D00 04 28 -CAS032923-TBL058128-DPR007428-DPR0074 2 8-T B L 03 3028-TBL05812 8 -T B L0 54 3 90-SCL007300-PCL000190-TBL035428-OVN0154 28-OVN015428-OVN011328-TBL0576 BOUNDARY BOUNDARYBOUNDARYBOUNDARYBOUNDARY BOUNDARYBOUNDARYBOUNDARY BOUNDARYBOUNDARYBOUNDARYBOUNDARY BOUNDARYBOUNDARYA A A.2 A.2 A.3 A.3 A.6 A.6 B B B.2 B.2 B.3 B.3 B.5 B.5 B.7 B.7 C C C.7 D D E E E.4 F F G G 6.9 H H 10 10 9 9 8 8 7 7 6.8 6.7 6 6 H.1 H.1G.5.3G.5.2 5 5 4.6 4.3 4.2 4 4 4.1 3.6 3.4 3.3 3 33.1 2.9 2.5 2.3 2 2 1.6 1.5 1.31.2 1 1 0.9 0.9 Y.4 Y.3 Y.2 Y.1 8.6 X.3 X.2 X Z.1W.1 7.8 6.5 B.9 C.3 C.5 C.6 D.1 D.5 D.8 E.3 E.6 E.7 F.1 F.2 F.3 F.5 F.6 F.7 F.8 G.1 G.4 G.5.1 G.5.4 G.6 0 0 0.3 0.33' - 0"3' - 0"5' - 0"8' - 0"0' - 6"0' - 1"5' - 5"4' - 5"0' - 7"5' - 2"5' - 1"2' - 5"5' - 5"2' - 7"5' - 4"7' - 3" P 3" FD-1 3" FD-1 3" FD-1 3" FD-1 1' - 5"4" DPCO 4" DPCO 4" DPCO -2' - 8 3/4" -2' - 2 1/4" -2' - 1 1/4" -2' - 2 3/4" 3" FUNNEL DRAIN 3"ø 3"ø 3"ø 3"ø 3"ø4"ø GR4"ø GR4"ø GR 4"ø GR145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.1/16"=1'-0"7/2/2019 2:46:16PMC:\Users\monom\Documents\071_Ithaca_PLUMB_CENTRAL_2017_monomCVV2R.rvtITHACAM501OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 ASTEY500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/2019 TBD BELOW GRADE STORM, SANITARY AND VENT PLAN10 5 3 1 B D F H KEY PLAN N.T.S N M501_4 M501_1 M501_2 M501_3 M501_5 M501_8 M501_7 M501_6 M501_12 M501_9 M501_10 M501_11 M501_13 M501_16 M501_15 M501_14 Revision Schedule # Date Revision 1 07/03/19 PERMIT SET PLM042 10-CAS039110-CAS039110-CAS039110-CAS039110-TBL060310-TBL060300-GRD000400-GRD000410-CAS031710-CAS029800-GRD000400-GRD000400-GRD000400-GRD000410-CAS029810-SCL006710-SCL006710-TBL070400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000410-TBL070410-TBL060310-TBL060310-TBL046410-TBL046410-TBL046410-TBL046410-TBL010010-TBL010010-TBL010010-WPR000210-CAB002710-CAB0027TBL0631VIF WIDTHVIF DEPTH2C01-3T2C08-1T2C01-2T2C04-022C04-042C04-032C04-052C04-012C04-062B29-012B29-022B29-032B29-042B29-052B30-031C01-011C01-021C01-031B05-0114CL-CD1B05-0222CL-CD1B01-011B01-021B01-031B01-041B01-051B01-061B02-011B04-0111CL-CD1B04-0212CL-CD1B04-0313CL-CD2A09-011CL-CD2B13-011B16-022A12-011B06-011B08-0129CL-CD1B15-0117CL-CD1B26-0128CL-CD2B08-011B26-012B10-013' - 0"3' - 0"5' - 0"8' - 0"4' - 3"EFGH109876H.15E.46.96.86.7G.5.3G.5.24.6Y.4Y.3Y.2Y.18.6Z.12B07-012B04-012B05-012B06-012B072B062B042B05LSVLSVLSVX - X2B OX - X2B IX - X2B IX - X2B OX - X2B IX - X2B OLSVX - X2B OX - X2B ILSV2C09CDS04 - 072C O2B23LSV05 - 032B OLSV1B2309 - 011B O2B09LSVXX - XX2B OLSVLSV1B1505 - 021B O04 - 081B OX - X1B O1B23-0230CL-CD1B23-0129CL-CD1B10-0119CL-CD1B10-0220CL-CD1B15-0224CL-CD1B15-0123CL-CD1B04-0313CL-CD1B04-0212CL-CD1B04-0111CL-CD1B05-0141CL-CD1B05-0242CL-CD1B26-0136CL-CD1B09-0118CL-CD2B13-0135CL-CD2B09-0212CL-CD2C09-0126CL-CD145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional SealSCALE:Store No:PRICING SET:PERMIT SET:CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.1/8"=1'-0"7/2/2019 12:59:23 PMC:\Users\cooneys\Documents\071_Ithaca_MECH_CENTRAL_2017_CooneyS.rvtITHACAM401_2OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET07/03/19MWSC500 SOUTH MEADOW STITHACA, NY 14850#071NA07/03/2019TBDQUADRANT 2 REFRIGERATION CONTROLS PLANNKEY PLANN.T.S531BDF10HM401_3M401_2M401_4M401_1Revision Schedule#Date Revision1 07/03/19 Permit SetCON039/071-5266ITHACA OLD WORLD CHEESE REMODEL INSTALLATION NOTESFOR ANALOG WIRING, USE CONTINOUS BELDEN 8761 22/2 OR EQUAL. DO NOT SPLICE WIRING. FOR DIGITAL WIRING, USE BELDEN 8761 22/2 OR EQUAL. IF WIRING DOES NOT REACH DESTINATION, INSTALL TERMINATION STRIP IN ACCESSIBLE LOCATION AND SPLICE WIRING AS NEEDED.SYSTEM BFOR CIRCUITS 2B04, 2B05, 2B06, AND 2B07, FURNISH AND INSTALL A TEMPERATURE SENSORS FOR EACH CASE. FURNISH AND INSTALL INPUT CONTROL WIRING AND WIRE CIRCUITS BACK TO CONTROLLER RX-5 (2B) IN POWERHOUSE B. PROGRAM TEMPERATURE SENSORS AS NEXT (4) FOUR AVALIABLE INPUT POINTS. IF NONE ARE AVAILABLE, EXTEND THE I/O NETWORK.FURNISH AND INSTALL OUTPUT CONTROL WIRING AND WIRE SOLENOID VALVES FOR CIRCUITS 2B04, 2B05, 2B06, AND 2B07 BACK TO CONTROLLER RX-5 (2B) IN POWERHOUSE B. PROGRAM AS NEXT (4) FOUR AVALIABLE OUTPUT POINTS. IF NONE ARE AVAILABLE, EXTEND THE I/O NETWORK.PROGRAMMING:PROGRAM CIRCUITS 2B04, 2B05, 2B06, AND 2B07 FOR TEMPERATURE CONTROL, OFF-TIME DEFROST, AND A LIGHT SWITCH.PROVIDE AS-BUILT DOCUMENTATION FOR ANY ASSOCIATED WORK. COFFEEBEANCABINET17-DPR003617-DPR003617-DPR003617-DPR003617-COFFEEROASTER17-CAB080517-CAB097817-CAB098417-CAB080517-CAB085217-CAB080617-BIN015117-REF016717-REF016717-REF016717-CAB092817-REF016717-REF011217-OVN010717-OVN010317-DPR013017-DPR012817-DPR012017-REF024417-REF021917-GDR000817-GDR000817-SCL005817-GDR000817-COFFEEBEANCABINET17-COFFEEBEANCABINET17-CAB074717-COFFEEBEANCABINET17-OVN010717-DPR003617-DPR003617-DPR003617-DPR003617-DPR003617-DPR003617-DPR003617-DPR003617-DPR003617-DPR003617-REF028517-GDR002617-WRM006517-BIN002417-SNK025317-SNK050810-CAS039110-CAS039110-CAS039110-CAS039110-TBL060310-TBL060300-GRD000400-GRD000410-CAS031710-CAS029800-GRD000400-GRD000400-GRD000400-GRD000410-CAS029803-CAS010403-CAS010407-CAS010507-CAS010507-CAS010507-CAS010507-CAS020600-GRD000600-GRD000607-STG023307-RGS000407-WKS019607-WKS019507-CAB037707-WKS023507-MED000107-FRZ006407-SHF0122 07-SHF012207-SHF0122 07-SHF012207-SHF012207-SHF012307-SHF012207-SHF012207-SHF012307-SHF012507-SHF012507-SHF012207-SHF012307-CAB057107-CAB057107-CAB036707-CAB036707-DPR010807-PNT001107-CAB036707-CAB036707-DPR01080 7 -M N R 0 0 1 5 07-MNR001507-PNT001007-CAB036707-CAB036707-DPR010807-CAB036707-CAB036707-DPR01080 7 -M N R 0 0 1 5 07-MNR001507-SNK015207-CAB017407-CAB010607-REF009607-CAB010607-CAB017407-CAB046007-CAB046107-CAB046107-CAB026607-CAB026607-CAB038407-CAB026607-CAB038407-CAB026607-PNT001407-SHF012207-SHF012307-WKS019607-WKS019607-WKS019607-CAB037807-RGS000407-CAB037807-RGS000407-CAB037807-RGS000407-WKS019507-CAB037707-CAB038407-WKS023507-MNR001507-PNT001407-MNR001507-CAB046307-CAB038407-STG023307-STG023310-SCL006710-SCL006710-TBL070407-DRG0009VIF WIDTH07-SHF020307-SHF020300-REF024200-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000410-TBL070410-TBL060310-TBL060310-TBL046410-TBL046410-TBL046410-TBL046410-TBL010010-TBL010010-TBL010010-WPR000210-CAB002710-CAB002707-STG023407-STG023407-STG023407-STG023407-STG023407-STG023407-STG023407-PNT001007-FAX07-WKS020924-STG010924-STG010924-STG010924-STG010924-STG010924-STG010924-STG010924-TBL0722ADA24-TBL0722ADA27-DIV007927-DIV007927-DIV007927-DIV007927-DIV007927-CPA003927-CPA003927-CPA003927-CPA003927-CPA0035 27-CPA0035 27-CPA0035 27-CPA003527-RGS000427-RGS000427-RGS000427-RGS000427-SCN0008 27-SCN0008 27-SCN0008 27-SCN000827-WKS039927-WKS0398 27-WKS039827-WKS040000-GRD000400-GRD000404-CAS0104 04-CAS010486-VND000486-TBL060086-SLC000986-TBL060086-SNK004886-REF016786-WRM005686-OVN011686-TBL069386-REF020186-TBL069386-REF020186-CAB085886-TBL03208 6 -D P R 0 0 9 3 86-ICM004486-CAB002786-DSK000486-TBL006286-RKM015238-KTL001338-KTL001338-SCL006738-SCL006738-SHF0258 38-SHF0258 38-SHF0258 38-SHF025838-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF007338-REF0124 38-REF012438-SHF025838-SHF025838-TBL035938-FDP000438-FDP002238-WPR000238-SHF022938-SHF022938-TBL048138-SNK0062CAB029938-SNK025538-TBL032038-OVN014638-RKM003238-RKM003238-RKM003238-CRT000738-CRT000438-CRT000438-CRT000438-CRT000438-RKM003238-RKM003238-CRT000738-RKM003238-RKM003238-SHF025838-SHF0258RKF0073 RKF007338-SNK025338-CNV002938-TBL0631VIF WIDTHVIF DEPTHTBL0631VIF WIDTHVIF DEPTH18-CRT000418-CRT000488-WRM002523-CAS008323-CAS033628-GRD000428-GRD000428-GRD000428-GRD000428-CAS032828-GRD00042 8 -G R D 0 0 0 428-G R D 0 0 0 428-GRD00042 8 -C A S 0 3 2 9 23-TBL058128-DPR007428-DPR007428-TBL033028-TBL058128-TBL054390-SCL007300-PCL000190-TBL035428-OVN015428-OVN015428-OVN011328-TBL0576BOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARY2A23-012A22-011A07-0127CL-CD1A07-0228CL-CD1A07-0329CL-CD2A08-0131CL-CD2A08-0232CL-CD2A08-0332CL-CD1A06-0426CL-CD2A04-0122CL-CD2A04-0223CL-CD2A04-0324CL-CD1A06-0325CL-CD1A06-0224CL-CD1A06-0123CL-CD1A04-0320CL-CD1A04-0219CL-CD1A04-0118CL-CD1A05-0121CL-CD1A05-0222CL-CD2B01-012A06-0227CL-CD2A06-0126CL-CD2A07-0330CL-CD2A07-0229CL-CD2A07-0128CL-CD2A05-0125CL-CD2A15-014CL-CD2A15-025CL-CD2A50-0313CL-CD2A50-0210CL-CD2A50-0109CL-CD2C11-012A49-0208CL-CD2A49-0107CL-CD1A01-0111CL-CD1A03-0217CL-CD1A01-0212CL-CD1A03-0116CL-CD1A01-0313CL-CD1A02-0215CL-CD2A03-0119CL-CD2A03-0220CL-CD2A03-0321CL-CD1A02-0114CL-CD2B12-01T2A02-0218CL-CD2A02-0117CL-CD2A01-0316CL-CD2A01-0215CL-CD2A01-0114CL-CD2B02-01T2A18-1T2A17-1T2A21-1T2A16-1T2C02-1T2C01-1T2C01-3T2C08-1T2C01-2T2B03-012C04-022C04-042C04-032C04-052C04-012C04-062B29-012B29-022B29-032B29-042B29-052B30-031C01-011C01-021C01-031B05-0114CL-CD1B05-0222CL-CD1B01-011B01-021B01-031B01-041B01-051B01-061B02-011B04-0111CL-CD1B04-0212CL-CD1B04-0313CL-CD2A09-011CL-CD2B13-011B16-022B20-012B19-012A12-012A10-01SREFRIG.TEMPFREEZERTEMPSFRZ1FRG21B20-011B20-021B20-032B11-011B06-011B08-0129CL-CD1B15-0117CL-CD1B15-0218CL-CD1B17-011B13-011B12-012B16-012A13-012B24-011B26-0128CL-CD2B08-011B26-012A11-0102CL-CD2A48-0103CL-CD2B14-012A14-012B23-012B17-01SFRG12B21-01CI05 - 03CI05 - 06CI05 - 062B28-012B10-01PHARMACY ALARM POINTS:06.05.03AI (PHARM. FRIDGE #2)06.05.05AI (PHARM. FRIDGE #1)06.05.06AI (PHARM. FREEZER #1)IF IN THE EVENT THE CPC PROGRAMMER DID NOT LABEL THE INPUT POINT, IT MAY APPEAR IN THIS FORMAT SHOWN BELOW.06.06.03AIINPUT POINTTYPE OF SIGNALINPUT BOARDCONTROLLER3' - 0"3' - 0"5' - 0"8' - 0"4' - 3"AAA.2A.2A.3A.3A.6A.6BBB.2B.2B.3B.3B.5B.5B.7B.7CCDDEEFFGGHH101099887766H.1H.155443322110.90.9000.30.3C.7E.46.96.86.7G.5.3G.5.24.64.34.24.13.63.43.33.12.92.52.31.61.51.31.2Y.4Y.3Y.2Y.18.6X.3X.2XZ.1W.17.86.5B.9C.3C.5C.6D.1D.5D.8E.3E.6E.7F.1F.2F.3F.5F.6F.7F.8G.1G.4G.5.1G.5.4G.62B07-012B04-012B05-012B06-012B072B062B042B05LSVLSVLSVX - X2B OX - X2B IX - X2B IX - X2B OX - X2B IX - X2B OLSVX - X2B OX - X2B ILSV2C09CDS04 - 072C O2B23LSV05 - 032B OLSVLSV1B241B2309 - 031B O09 - 011B O2B092B252B26LSVLSVLSVLSV2C102C05XX - XX2B O09 - 052B OXX - XX2B OXX - XX2C OXX - XX2C OLSVLSVLSVLSVLSVLSVLSV1B151B141B251B191B0705 - 021B O04 - 081B OX - X1B OX - X1B O08 - 011B O05 - 061B O2B221B24-0334CL-CD1B24-0235CL-CD1B24-0132CL-CD1B23-0331CL-CD1B23-0230CL-CD1B23-0129CL-CD1B10-0119CL-CD1B10-0220CL-CD1B15-0224CL-CD1B15-0123CL-CD1B04-0313CL-CD1B04-0212CL-CD1B04-0111CL-CD1B05-0141CL-CD1B05-0242CL-CD1B26-0136CL-CD1B09-0118CL-CD1B14-0121CL-CD1B14-0222CL-CD1B25-0135CL-CD1 B 2 7 -0 339CL-C D1B2 7 -0 238CL-C D1B2 7 -0 137CL-C D 1B19-0428CL-CD1B19-0327CL-CD1B19-0226CL-CD1B07-0114CL-CD1B07-0215CL-CD1B07-0316CL-CD1B11-0140CL-CD2B13-0135CL-CD2B09-0212CL-CD2B09-0113CL-CD2B25-0217CL-CD2B25-0116CL-CD2B13-0135CL-CD2B26-0321CL-CD2B26-0220CL-CD2B26-0119CL-CD2B22-0215CL-CD2B22-0114CL-CD2B28-0124CL-CD2C05-0118CL-CD2C05-0219CL-CD2C09-0126CL-CD2C10-0127CL-CD2C10-0228CL-CD2C06-0120CL-CD2C06-0221CL-CD145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road, Suite 200Rochester NY, 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional SealSCALE:Store No:PRICING SET:PERMIT SET:CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.1/16"=1'-0"7/2/2019 1:00:39PMC:\Users\cooneys\Documents\071_Ithaca_MECH_CENTRAL_2017_CooneyS.rvtITHACAM401OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET07/03/19MWSC500 SOUTH MEADOW STITHACA, NY 14850#071NA07/03/2019TBDREFRIGERATION CONTROLS PLANNKEY PLANN.T.S10531BDFHM401_3M401_2M401_4M401_1ITHACA OLD WORLD CHEESE REMODEL INSTALLATION NOTESFOR ANALOG WIRING, USE CONTINOUS BELDEN 8761 22/2 OR EQUAL. DO NOT SPLICE WIRING. FOR DIGITAL WIRING, USE BELDEN 8761 22/2 OR EQUAL. IF WIRING DOES NOT REACH DESTINATION, INSTALL TERMINATION STRIP IN ACCESSIBLE LOCATION AND SPLICE WIRING AS NEEDED.SYSTEM BFOR CIRCUITS 2B04, 2B05, 2B06, AND 2B07, FURNISH AND INSTALL A TEMPERATURE SENSOR FOR EACH CASE. FURNISH AND INSTALL INPUT CONTROL WIRING AND WIRE CIRCUITS BACK TO CONTROLLER RX-5 (2B) IN POWERHOUSE B. PROGRAM TEMPERATURE SENSORS AS NEXT (4) FOUR AVALIABLE INPUT POINTS. IF NONE ARE AVAILABLE, EXTEND THE I/O NETWORK.FURNISH AND INSTALL OUTPUT CONTROL WIRING AND WIRE SOLENOID VALVES FOR CIRCUITS 2B04, 2B05, 2B06, AND 2B07 BACK TO CONTROLLER RX-5 (2B) IN POWERHOUSE B. PROGRAM AS NEXT (4) FOUR AVALIABLE OUTPUT POINTS. IF NONE ARE AVAILABLE, EXTEND THE I/O NETWORK.PROGRAMMING:PROGRAM CIRCUITS 2B04, 2B05, 2B06, AND 2B07 FOR TEMPERATURE CONTROL, OFF-TIME DEFROST, AND A LIGHT SWITCH.PROVIDE AS-BUILT DOCUMENTATION FOR ANY ASSOCIATED WORK.Revision Schedule# Date Revision1 07/03/19 Permit SetCON039/071-5266 NETWORK TERMINATION ON THE TWO END DEVICES SET SWITCH 7 IN THE UP (ON) POSITION TO SET THE BAUD RATE TO 9600 BAUD SET SWITCH 8 IN THE DOWN (OFF) POSITION TO SELECT NO PARITY CONTROL LINK MODULE (LEFT SIDE VIEW) UNTERMINATED TERMINATED UNBIASED SET JUMPERS TO TERMINATE ON THE TWO END DEVICES BIASED ON ONE END DEVICE, UNBIASED ON THE OTHER END DEVICE TERMINATED BIASED E2 CL-CD #1 CL-CD #2 CL-CD #3 NETWORK ADDRESSING SWITCH #1 2 3 4 5 6 ADDRESS 1 2 4 8 16 32 EXAMPLE ADDRESS #1 1 ADDRESS #2 2 ADDRESS #11 1 2 8 SWITCHES 1-6 NETWORK ADDRESSING SWITCH IN "ON" POSITION ADDS ADDRESS # TO NETWORK ID BAUD RATE & PARITY TERMINATION JUMPER SETTINGS COMMUNICATION WIRING DETAILS NOTE: IF EMI RELATED PROBLEMS OCCUR, EARTH GROUNDING OF THE COMMUNICATION NETWORK SHIELD IS ADVISED BY CPC. CONNECT THE 0V TERMINAL OF THE E2'S I/O NETWORK PORT TO A SOLID EARTH GROUND. THE WIRE FROM THE 0V TERMINAL TO GROUND SHOULD BE 14 AWG WIRELESS THAN SIX (6) INCHES LONG. +485 SHIELDED TWISTED PAIR BELDEN 8641 24/2 TO OTHER RS485 DEVICES WIRE RS485+ TO RS485+ WIRE RS485- TO RS485- CONNECT SHIELDS TO OV -485 NET0V (SHIELD) RS 485 BOARD CONNECTION I/O NETWORK TO OTHER RS485 DEVICES THERMOSTAT FOR ACR TEMPERATURE CONTROL PROVIDED W/ ACR. CABLING FURNISHED AND INSTALLED BY CONTROLS CONTRACTOR. GLYCOL OR CO2 SOLENOID VALVE -PROVIDED BY REF. CONTRACTOR AND WIRED BY CONTROLS CONTRACTOR. SEE REFRIGERATION SCHEDULES FOR VALVE SELECTION. REFRIGERATION CONTROLS LEGEND INPUT BOARD TERMINATION POINTS -USE CONTINUOUS BELDEN 8641 22/2 NON-SHIELDED OR EQUAL OR OTHERWISE NOTED (ALL CPC CONTROLS USING BELDEN CABLE, NEED TO BE IN ITS OWN CONDUIT OR TRAY) SOLENOID VALVE TYPE REFRIG. CIRCUIT DESIGNATION CIRCUIT TEMPERATURE SENSOR W/20' LEADS, CPC PART # 501-1122, USE CONTINUOUS BELDEN 8761 22/2. SHIELD GROUNDED AT CASE CONTROLLER END ONLY. CONTROLS CONTRACTOR TO FURNISH AND INSTALL SENSORS INSIDE WALK-IN COOLERS AND FREEZERS AT 15" OFF CEILING TO CENTER OF BOX AND WIRE TO CASE CONTROLLERS OUTSIDE OF COOLERS AND FREEZERS. CONTROL LINK CASE CONTROLLER W/RED DISPLAY, CPC PART # 846-2064. CASE CONTROLLERS ARE PROVIDED BY CASE MANUFACTURER IN CASES SHOWN. CONTROLS CONTRACTOR TO FURNISH AND INSTALL AT COOLERS AND FREEZERS AND WIRE TO TEMPERATURE SENSORS INSIDE COOLERS AND FREEZERS. RELAY EXPANSION BOARD, CPC PART # 846-1120, ARE TO BE PROVIDED BY CASE MANUFACTURER AND CONTROLS CONTRACTOR WITH THE CASE CONTROLLER AS REQUIRED. EVAPORATOR DEFROST TEMPERATURE SENSOR W/20' LEADS, CPC PART # 501-1127, USE CONTINUOUS BELDEN 8761 22/2. SHIELD GROUNDED AT CASE CONTROLLER END ONLY. CONTROLS CONTRACTOR TO FURNISH AND INSTALL ON EVAPORATOR PIPING IN COOLERS AND FREEZERS. QTY DRY CONTACT CLOSURE, INPUT. USE CONTINUOUS RUN 22/2 AWG BELDEN 9418 OR EQUAL RACK TEMPERATURE SENSOR, "CPC PART #201-2007". FURNISHED AND INSTALLED ON WALL OR COLUMNS BY CONTROLS CONTRACTOR. USE CONTINUOUS RUN 22/2 BELDEN 8761. REFRIGERATION CIRCUIT NUMBER AND SOLENOID VALVES CONNECTED WITH THIS SYMBOL ARE TO BE WIRED BACK TO THE CONTROL LINK W/ #14 THHN, PER EACH OUTPUT SHOWN. THE SOLENOID VALVE(S) ARE TO BE WIRED TO THE #1 CONTROL LINK IN THE LINE-UP. TEMPERATURE SENSOR (ON PIPE). FURNISHED AND WIRED BY CONTROLS CONTRACTOR. INSTALLED ON PIPE BY PLUMBING CONTRACTOR. USE CONTINUOUS RUN 22/2 BELDEN 8761. 120V ROTATING RED WARNING LIGHT, FEDERAL SIGNAL MODEL 141ST-120R OR EQUAL, FURNISHED AND INSTALLED TO UNDERSIDE OF CEILING BY CONTROLS CONTRACTOR. NOTE: ALL WIRING AND COMPONENTS TO BE SUPPLIED BY CONTROLS CONTRACTOR ARE J-BOXES, DISCONNECTS, CONDUIT, AND WIRING ACCESSORIES, AS NOTED ABOVE. CONTROLS CONTRACTOR CAN USE MULTI-CONDUCTOR CABLES FOR MULTIPLE SENSORS IN COMMON GROUPINGS. MULTIFLEX 168 -16 ANALOG/DIGITAL INPUTS, 8 RELAY OUTPUTS. FURNISHED WITH POWERHOUSE UNLESS OTHERWISE SPECIFIED MULTIFLEX 168AO -16 ANALOG/DIGITAL INPUTS, 8 RELAY OUTPUTS, 4 ANALOG OUTPUTS. FURNISHED WITH POWERHOUSE UNLESS OTHERWISE SPECIFIED. 8ROSMT -OUTPUT BOARD W/ 8 FORM C RELAY OUTPUTS. FURNISHED WITH POWERHOUSE UNLESS OTHERWISE SPECIFIED DIFFERENTIAL PRESSURE TRANSMITTER. 4-20 mA, WIRED TO GLYCOL PUMP SKID PLC INPUT. FURNISHED BY POWERHOUSE MANUFACTURER AND INSTALLED BY CONTRACTOR. PHARMACY REFRIGERATOR/FREEZER TEMPERATURE SENSOR W/20' LEAD, CPC PART #501-1122. INSTALL ONE IN REFRIGERATOR AND ONE IN FREEZER. USE CONTINUOUS RUN 22/2 BELDEN 8761. DOOR SWITCH, GE SENTROL 2507A. PMAC II CHANNEL FOR LOW TEMP CASE DOOR ANTI-SWEAT HEATERS. THE FIRST NUMBER INDICATES THE OUTPUT POINT ON THE ASSOCIATED 8DO OUTPUT BOARD, THE SECOND NUMBER INDICATES THE ANTI-SWEAT CHANNEL CIRCUIT CPC DEWPOINT SENSOR, CPC PART# 203-1902, FURNISHED AND INSTALLED ON WALL OR COLUMNS BY CONTROLS CONTRACTOR. USE CONTINUOUS RUN 22/4 BELDEN 8729 FOR 700 FEET OR LESS AND #9418 FOR 700 FEET TO 1800 FEET XXXX-XX XX CL-CD XXXX-XXD X XX X - XX DP CC SV T TS S TP DT XX X CASE RELATIVE HUMIDITY PROVIDED AND INSTALLED BY CASE MANUFACTURER. WIRED BY CONTROLS CONTRACTOR. USE CONTINUOUS RUN 22/3 BELDEN 8771. CH DS HOMERUN TO DEVICE FROM DESIGNATED PANEL I -INPUT INPUT BOARD # CONTROLLER O -OUTPUT OUTPUT BOARD # CONTROLLER AO -ANALOG OUTPUT ANALOG OUTPUT BOARD # CONTROLLER CIRCUIT QTYRACK XXXX-XXT CIRCUIT CASE RACK ADDRESS 145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.NONE7/2/2019 3:19:33 PMC:\Users\monom\Documents\071_Ithaca_MECH_CENTRAL_2017_monomCVV2R.rvtITHACAM400BOLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 MWSC500 SOUTH MEADOW STITHACA, NY 14850#071 NA 07/03/2019 TBD REFRIGERATION CONTROLS NETWORK ARCHITECTURE AND LEGENDSSCALE:NOT TO SCALEBI/O BOARD AND CONTROL LINK COMMUNICATION WIRING DETAILS SCALE:NOT TO SCALE REFRIGERATION CONTROLS LEGENDA Revision Schedule # Date Revision 1 07/03/19 Permit Set CON039/071-5266 MATCHLINEMATCHLINEMATCHLINEMATCHLINEMATCHLINE MATCHLINE MATCHLINE MATCHLINE 38M B QB 38M B QB 38M B QB 1'-0" 23'-0" 2'-2" 3'-2" 24'-2" 1'-10" 4'-10" 29'-4" 2'-9" 1C-4 SPARELOOP 1C LOOP 2C 2C-9 SPARE REFRIGERANT CHARGE +15+20RAIL & TROLLEYRECEIVER RELIEF LINE FROMPOWERHOUSE. CLEAR POWERHOUSE ROOF AND POSITION UP. SEEDETAIL B, ON M-309. CONTRACTOR TO PROVIDEUNISTRUT SUPPORT AS REQUIRED. CONDENSERC1 LIQUID LINE TO RECEIVER IN HOUSE.PIPE TO BE RUN UNDER PLATFORM TO PREVENT TRIPPING HAZARD. DISCHARGE LINES FROMPOWERHOUSE. RUN PIPE UP HIGH AS POSSIBLE. C POWERHOUSE20000 LBS. 5"∅ B-VENT FLUE UP FROM UH-6 BELOW.CONTROLPANELPIPEMANIFOLD2730lbs.C1 CU-01 EXHAUST FAN (E-57) FOR CONVECTION OVENS MOUNTED ON ROOF CURB. EXHAUST FAN (E-59) FOR SCULLERY GEN. EXHAUST MOUNTED ON ROOF CURB. EXHAUST FAN (E-58) FOR SCULLERY DISHWASHER MOUNTED ON ROOF CURB. EXHAUST FAN (E-6) BAKERY GENERAL EXHAUST MOUNTED ON ROOF CURB. EXHAUST FAN (E-5) BAKERY MIWE OVEN MOUNTED ON ROOF CURB. 11,100 LBS AD-1 9,850 LBS AC-3EDS B32" OPENING TOPOWERHOUSE B44" OPENING TO32" OPENING TOEDS BPOWERHOUSE B44" OPENING TO ELEC. BOX 15,442 LBS AC-2 ELEC. BOX ELEC. BOXBRX-118APIPING ENDEDS "A"DOORELEC. BOX8 F.P.I.LBS.1,580BRX-O52APIPING END10 F.P.I.LBS.3,190DOORAC-1 15,442 LBS.PIPING ENDA HOUSE ELEC. BOXBRX-118A10 F.P.I.LBS.3,190DOOR1,222 LBS 10 TON AC-4 1,222 LBS 10 TON AC-5 5 TON AC-7 10 TON A/C-6 1300 LBS. HR-1 752 LBS. 5 TON A/C-8 34,000 LBS. EDS "B" DOOR 3,990 LBS. 8 F.P.I B HOUSE PIPING END BRX-154A BRX-154A PIPING END 8 F.P.I LBS. 3,990 DOOR SEE DETAIL "A" A/C-9 752 LBS. 40,000 LBS. 752 LBS. 1,222 LBS 1'-0" 6'-3" 1'-0" 8" 6'-1" CU-22 CU-24 CU-23 GV-1 (TYP.) CONDENSING UNIT MOUNTED ON EQUIPMENT RAILS. REFER TO DETAIL 'A' ON DRAWING M312. (TYP. OF 3) "THE VAULT" REFRIGERATION PIPING ENCLOSURE. REFER TO DETAIL 'B' ON DRAWING M312. (TYP. OF 2)MATCHLINEMATCHLINEMATCHLINEMATCHLINEMATCHLINE MATCHLINE MATCHLINE MATCHLINE 38M B QB 38M B QB 38M B QB 1'-0" 23'-0" 2'-2" 3'-2" 24'-2" 1'-10" 4'-10" 29'-4" 2'-9" 1C-4 SPARELOOP 1C LOOP 2C 2C-9 SPARE REFRIGERANT CHARGE +15+20RAIL & TROLLEYRECEIVER RELIEF LINE FROMPOWERHOUSE. CLEAR POWERHOUSE ROOF AND POSITION UP. SEEDETAIL B, ON M-309. CONTRACTOR TO PROVIDEUNISTRUT SUPPORT AS REQUIRED. CONDENSERC1 LIQUID LINE TO RECEIVER IN HOUSE.PIPE TO BE RUN UNDER PLATFORM TO PREVENT TRIPPING HAZARD. DISCHARGE LINES FROMPOWERHOUSE. RUN PIPE UP HIGH AS POSSIBLE. C POWERHOUSE20000 LBS. 5"∅ B-VENT FLUE UP FROM UH-6 BELOW.CONTROLPANELPIPEMANIFOLD2730lbs.C1 CU-01 EXHAUST FAN (E-57) FOR CONVECTION OVENS MOUNTED ON ROOF CURB. EXHAUST FAN (E-59) FOR SCULLERY GEN. EXHAUST MOUNTED ON ROOF CURB. EXHAUST FAN (E-58) FOR SCULLERY DISHWASHER MOUNTED ON ROOF CURB. EXHAUST FAN (E-6) BAKERY GENERAL EXHAUST MOUNTED ON ROOF CURB. EXHAUST FAN (E-5) BAKERY MIWE OVEN MOUNTED ON ROOF CURB. 11,100 LBS AD-1 9,850 LBS AC-3EDS B32" OPENING TOPOWERHOUSE B44" OPENING TO32" OPENING TOEDS BPOWERHOUSE B44" OPENING TO ELEC. BOX 15,442 LBS AC-2 ELEC. BOX ELEC. BOXBRX-118APIPING ENDEDS "A"DOORELEC. BOX8 F.P.I.LBS.1,580BRX-O52APIPING END10 F.P.I.LBS.3,190DOORAC-1 15,442 LBS.PIPING ENDA HOUSE ELEC. BOXBRX-118A10 F.P.I.LBS.3,190DOOR1,222 LBS 10 TON AC-4 1,222 LBS 10 TON AC-5 5 TON AC-7 10 TON A/C-6 1300 LBS. HR-1 752 LBS. 5 TON A/C-8 34,000 LBS. EDS "B" DOOR 3,990 LBS. 8 F.P.I B HOUSE PIPING END BRX-154A BRX-154A PIPING END 8 F.P.I LBS. 3,990 DOOR SEE DETAIL "A" A/C-9 752 LBS. 40,000 LBS. 752 LBS. 1,222 LBS 1'-0" 6'-3" 1'-0" 8" 6'-1" CU-22 CU-24 CU-23 GV-1 (TYP.) CONDENSING UNIT MOUNTED ON EQUIPMENT RAILS. REFER TO DETAIL 'A' ON DRAWING M312. (TYP. OF 3) "THE VAULT" REFRIGERATION PIPING ENCLOSURE. REFER TO DETAIL 'B' ON DRAWING M312. (TYP. OF 2)STORMSTORMSTORMHOSE REELBULK OIL C.B.C.B.C.B. C.B.C.B.C.B. CORD REEL CORD REEL BIN BINBIN BIN PALLET PALLET PALLET HOSE REEL PALLET PALLET PALLET PALLET PALLET PALLET PALLETPALLET PALLET PALLET PALLET PALLETPALLET PALLET PALLETPALLET PALLET PALLETPALLETPALLETPALLET PALLETPALLETPALLET PALLET PALLET PALLET HOSE REEL CORD REEL CORD REEL CORD REEL CORD REEL MINI CORD REEL BATTERYRACK CORD REEL PICK UP POINT WKS056 HOSE REEL HOSE REEL 028 LOTTOLOTTOICELOTTOMONEYORDER PUBLICASSIST. RELOC'D METRO RACK METRO RACK REF REF FUTUREFUTURE CARTSTORAGE TBL057900-GRD0006 00-GRD0006 00-GRD0006 00-GRD0006 00-GRD0004 00-GRD000400-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD0006 00-GRD0006 00-GRD000600-GRD000600-GRD0006 00-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD000600-GRD0006 00-GRD000600-GRD000600-GRD000600-GRD0006 00-GRD0006 00-GRD000600-GRD000600-GRD0006 00-GRD000600-GRD0006 00-GRD0004 00-GRD0004 00-GRD000600-GRD0006 00-GRD0006 00-GRD0006 00-GRD0004 00-GRD0004 00-GRD0006 00-GRD0006 00-GRD0006 00-GRD0006 01-REF003101-SHF0054 01-SHF0054 01-SHF0054 01-SHF0054 01-RKM001601-SHF0054 01-SHF005401-SHF005501-RKM0004 01-RKM0004 01-RKM0004 01-RKM0004 01-RKM0004 01-RKF000701-SNK0004 01-SNK003301-RKF000701-RKF000701-KTL0004 01-SHF005401-SHF005501-SHF0055 01-RKM001601-R KM001601-SHF005401-SHF005401-SHF005501-TBL008601-DPR001101-DPR0006 01-DPR0006 01-DPR0006 01-DPR0006 01-CAB0018 01-CAB001801-KTL000501-CAB001801-TBL008201-SLC0014 01-SNK000401-SNK001601-DPR000101-DWS000701-RKM000401-RKF000901-RKF0009 01-RKF0010 01-RKM0004 01-RKM0004 01-CRT0003 01-RKF000901-RKF001001-RKM003401-SNK003201-SNK000401-RKM0161 01-RKM0161 01-RKM0161 01-RKM0161 01-RKM0161 01-RKM0161 01-RKM0161 01-RKM0161 01-RKM0161 01-RKM0161 01-RKM0161 01-RKM0161 01-PFR003701-PFR003701-RKM018801-RKM018801-RKM018801-RKM018801-RKM018801-RKM018801-RKM018801-RKM018801-RKM018801-RKM018801-RKM018801-RKM018801-RKM018801-RKM0188 01-RKM0188 01-RKM0188 01-RKM0188 01-RKM0188 01-RKM0188 01-TBL009701 -D PR0001 01-RKM017001-RKM017001-TBL0097 01-TBL0350 01-TBL0350 01-RKM0170 01-TBL0158 01-RKM017001-RKM015201-RKM0152 01-OVN0011 01-BIN0001 01-TBL065101-CAB002701-BIN000101-TBL0017 01-MXR0002 MXR0023 01-TBL0464 01-SLC0007 01-TBL0433 01-SLC0001 01-TBL0603 01-SHF0329 01-SHF0329 01-SHF0329 01-TBL0464 01-TBL0464 01-SHF0329 01-TBL0471 01-R KM 002101-SHF0329 01-CAS015001-SCL002101-CAS015401-SCL002101-CAS015101-TBL043301-TBL065901-CMP000101-TBL009801-SHF005201-CAS0152 01-CAS014901-REF003101-SNK0052 01-TBL065101-OVN012001-BIN0001 01-BIN0001 01-BIN0001 01-BIN0001 01-TBL047101-TBL060001-OVN018201-OVN018101-OVN018101-RKM0188 01-RKM0188 01-RKM0188 01-RKM0188 01-RKM0188 01-RKM0188 01-RKM0188 01-RKM0188 01-RKM0188 01-TBL047201-TBL008301-CAS014901-TBL067801-TBL067801-TBL067801-SHF032901-SHF032901-GRD000401-OVN001601-DSK000401-DSK0004 01-RKM0152 01-BIN0031 CAS0370CAS0370CAS037002-0103 02-CAS0216 02-CAS021502-CAS021402-CAS0216 02-CAS0215 02-CAS021402-GRD000402-GRD000402-RKM0118 02-RKM0118 02-RKM0118 02-RKM011802-CAB002702-DSK0004 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF005402-SHF0054 02-SHF005902-SHF005902-SHF005902-SHF005902-SHF005902-SHF0059 02-RKM0101 02-RKM0101 02-CRT0018 02-CRT0018 02-CRT0018 02-CRT0019 02-CRT0019 02-CRT0019 02-CRT0019 02-CRT0019 02-CRT0019 02-CRT0019 02-CRT0019 02-CRT0019 02-CRT0019 02-CRT0019 02-CRT0019 02-CRT0019 02-CRT0019 02-CRT0019 02-CRT0019 02-GRD0004 0 2-CAS0056 02-C AS0 0 5 6 02-R KM0 1 01 0 2-RKM0101 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF0054 02-SHF005902-SHF005902-SHF005902-SHF005902-SHF005902-SHF005902-SHF005902-SHF005902-SHF005902-SHF005902-SHF005902-SHF005902-SHF005902-SHF005902-SHF005902-SHF005902-SHF0059 02-RKM0101 02-RKM0101 02-RKM0101 02-RKM0101 02-RKM0101 02-RKM0101 02-RKM0101 02-RKM0101 02-RKM0101 02-RKM0101 02-RKM0101 02-RKM0101 02-RKM0101 02-CAS0055 02-CAS0055 02-CAS0055 02-GRD0004 CAS247CAS247CAS248CAS248CAS248 02-CAS021602-CAS0215 02-CAS021402-CAS021602-CAS0215 02-CAS021402-GRD000402-RKM0118 02-RKM0118 02-RKM0118 02-RKM0118 02-CAS0216 02-CAS0216 02-CAS0104 02-CAS0104 03-ICM001303-ICM001303-TBL059603-DIV006003-SCL006703-JCR000603-WPR000103-TBL059603-SNK016303-SNK025303-CAS0274 03-CAS0274 03-CAS0298 02-CAS0298 03-CAS0298 03-CAS0298 03-CAS029803-TBL028503-STD002503-SCL006103-TBL028503-STD002503-SCL006103-TBL0690 03-CAS0296 03-CAS0327 RKM0123 03-RKM0152 03-SCL0067 03-DSK002403-TBL054303-TBL064103-BIN0151 03-REF021103-JCR0008 03-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010403-CAS010403-CAS010503-CAS010503-DPR011403-DPR011403-DPR011403-DPR0115 03-DPR011503-DPR011403-DPR011403-CAS034403-CAS034503-FRZ006903-TBL057703-SCL007103-MXR002503-CAS037003-CAS037003-FRZ005803-CRT003803-DPR011403-CAS0206 03-WPR002403-TBL016203-TBL016203-TBL0162 03-TBL0162 03-TBL0162 03-TBL016203-CAS0182 03-TBL0162 03-STD002503-SCL0061 CAS0356CAS0356CAS0356CAS0356 03-CAS0298 03-CAS0298 03-SCL006103-TBL0162 03-TBL028503-STD0025 03-SCL0061 03-STD002503-TBL028503-TBL028503-STD002503-SCL006103-TBL028503-STD002503-SCL006103-TBL0162 03-CAS0182 03-TBL0162 03-TBL0162 03-TBL0162 03-TBL0162 03-TBL0162 03-TBL0162 03-TBL0162 03-TBL0162 03-TBL0162 03-STD002503-SCL0061 10-CAS0298 03-TBL0162 03-TBL0162 03-STD002503-TBL028503-STD0025 03-TBL028503-STD002503-SCL006103-STD002503-TBL028504-RKF0030 04-RKF0030 04-REF005204-CAS005504-CAS005600-GRD000400-GRD000404-REF0052 04-CAS010404-CAS0104 05-RKM0031 05-RKM008605-RKM008605-RKM0086 05-CAB002805-CAB002805-CAB0028 05-GRD0004 05-CAS0096 05-CAS009605-CAS009505-CAS009505-CAS009505-CAS009605-CAS0096 05-TBL000605-TBL004405-SHF000805-TBL004405-GDR000205-BIN001805-BIN0020 05-BIN0020 05-BIN002005-TBL000705-SLC000405-TBL000505-SHF000805-GDR000405-GDR000305-RKM010105-RKM0086 05-RKM0086 05-RKM0086 05-RKM008605-RKM010105-RKM010105-RKM010105-TBL0158 05-TBL015805-SCL003105-CRT000405-SHF0054 05-SHF0054 05-SHF0054 05-SHF0054 05-SHF0054 05-SHF005405-SHF005505-RKM010105-RKM0101 05-RKM010105-SNK000405-DPR0001 05-CMP000205-CAB002805-RKM0032 05-RKM0032 05-SLC001705-TBL009905-SLC000418-BIN015218-ICM004205-SAW000205-DPR0084 05-TBL0319 05-WPR0011 05-SCL0052 05-SCL005105-SHF0211 05-RKF007305-RKF0073 18-SNK006218-SNK0255 05-TBL0044 05-GDR000105-GDR000205-SCL003805-SHF009705-SHF009705-CAS021905-CAS009005-SHF010605-GRD000705-GRD0007 05-GRD000405-GRD0004 25-CAS0102 00-GRD0006 05-CAS009605-CAS0096 05-CAS029905-CAS029805-CAS0274 FRZ0062 FRZ0062REF0226REF0226REF0226 REF0226 06-CAS0314 06-CAS031506-SNK029877-WPR000406-SLC0003 06-SLC0003 06-RKM015306-RKM0153 06-RKM015306-RKM015306-RKM015306-RKM015306-RKM002906-SHF005406-SHF005406-SHF005406-SHF0054 06-SHF005506-SHF005506-SHF005506-SHF005506-SHF0055 06-RKM0032 06-RKM0032 06-CRT000406-SHF0054 06-SHF0054 06-SHF0054 06-SHF0055 06-SHF0055 06-SHF0055 06-SHF0055 06-SHF0055 06-SHF0054 06-RKM0029 06-CAS037406-CAS0312 06-CAS0312 06-CAS0312 06-CAS031206-SHF010806-SLC000206-SCL002306-SLC000206-TBL001806-SCL002306-SLC000206-TBL001806-SCL002306-SLC000206-TBL001806-SCL002306-TBL015906-TBL001806-CAS009606-CAS022007-SHF012207-SHF012207-SHF0122 07-SHF012307-SHF0123 07-SHF012207-SHF012207-SHF012207-SHF012207-SHF0122 07-SHF012207-SHF012507-SHF012507-SHF020307-SHF0203 07-CAB036707-CAB036707-CAB036707-CAB036707-WKS019507-WKS019507-DRG000907-WKS019607-WKS019607-WKS019607-WKS020907-WKS0196 07-CAB038707-CAB038707-CAB038707-CAB0387 07-REF009607-CAB010607-CAB010607-CAB046007-CAB046107-CAB046107-SHF0122 07-CAB034107-CAB010507-TBL0370 07-TBL037007-CAB017407-CAB038407-CAB038407-CAB037707-CAB037707-CAB026607-CAB026607-CAB038407-MNR001507-MNR001507-CAB037807-CAB037807-CAB0378 07-TBL040707-CAB017407-CAB036707-CAB046307-OVN007707-MNR001507-FXM000507-MNR001507-MED000107-CPA0022 07-CPA0022 07-DPR0025 07-REF003707-CPA0022 07-RGS0004 07-RGS0004 07-RGS000407-FRZ006407-STG023307-STG023307-STG0233 07-STG023407-STG023407-STG0234 07-SHF0123 07-CAB057107-CAB057107-SHF012307-MNR001507-MNR0015 07-RGS0004 07-CPA0022 07-SCN0001 07-SCN000107-SCN000107-SCN000107-WKS020907-WKS0235 07-WKS023507-STG011607-STG011607-CAB026607-CAB038407-MNR001507-CAB026607-MNR001507-CAB038407-SNK015207-DPR010807-DPR010807-DPR010807-DPR010807-MNR001507-MNR001507-MNR001 50 7-MNR00 15 07-SCN001007-MNR0 01 507-SCN001007-SCN001007-SCN001007-PNT001407-PNT001407-PNT001407-PNT001407-PNT001407-SCN001007-MNR0 01 507-PNT001107-CAB046307-CAB017310-SNK026310-SNK025310-REF004210-CAS0239 06-SLC001910-TBL005110-CAS029910-TBL046410-TBL07041 0-TB L 06 0 3 10 -T BL 0 60 3 10-TBL0464 10-TBL0464 00-GRD0006 00-GRD0006 10-CAS004810-CAS0048 10-CAS0274 00-GRD0004 00-GRD0004 00-GRD0004 00-GRD0004 10-CAS0317 10-CAS023910-CAS023910-CAS029910-CAS029910-TBL005110-CAB0027 10-TBL005110-GDR000610-TBL005110-CAS030010-CAS030010-CAS023910-TBL0521 10-TBL0464 10-CAS0169 10-TBL046410-SNK005010-WPR000210-CAS0298 10-CAS0298 10-TBL0603 10-TBL060310-TBL005110-CAS0325 10-CAS0325 10-CAS0325 10-CAS032533-CAB002733-DSK0004 12-SHF0310 12-SHF0310 12-SHF0310 12-SHF0310 12-SHF0205 12-SHF0205 12-SHF0205 12-SHF0205 12-CAB002733-CAB0032 12-SHF024012-SHF024012-SHF024012-SHF024012-SHF024012-SHF024012-SHF023912-DSK000412-TBL0260 12-TBL0260 12-TBL0260 12-TBL0260 13-CAB070813-CAB070813-SNK033213-MXR002413-CAB070713-CAB070713-CAB070713-TBL056413-TBL057213-TBL057213-TBL057213-TBL057213-TBL054113-TBL054113-TBL054113-TBL054113-RKM018013-TBL060413-TBL060513-TBL060613-TBL0605 13-TBL0606 1 3- T B L 06 05 1 3-CA B0 7 0 9 13-TB L 06 05 13-TB L 06 06 1 3-TBL 06 0513-TBL 06 06 1 3- T B L 06 06 13-TB L 06 05 1 3-CA B0 7 0 9 1 3- T B L 06 05 1 3-TBL 0 6 0 6 1 3- T B L 06 05 1 3-TBL 0 6 0 6 1 3-TBL 06 06 13-TBL060413-TBL060513-TBL060513-TBL0605 13-TBL0605 13-TBL060613-TBL060613-TBL0606 13-TBL0606 13-TBL0604 13-TBL0605 13-TBL060613-PNT001414-CAB002714-DSK0004 14-RKM010114-RKM010114-RKM010114-CAS027714-CAS027714-CAS023314-CAS010014-CAS0102 14-CAS023314-CAS023314-CAS023214-CAS023214-CAS027714-CAS027714-CAS010014-CAS0102 14-CAS010014-CAS023214-CAS023214-CAS023214-CAS0100 14-CAS010214-CAS010814-CAS010814-CAS010214-CAS010814-CAS010814-CAS010214-CAS023214-CAS010814-CAS010814-CAS010814-CAS010814-RKM010114-RKM010114-RKM010114-RKM010114-RKM010114-RKM010114-RKM010114-RKM010114-RKM010114-RKM0101 14-RKM0101 14-RKM010115-0114 15-012115-010315-0104 15-0109 15-012515-0113 15-0103 15-012915-012915-012915-MNR0012 15-CPA0024 15-RGS0003 15-CPA0020 15-PNT0006 15-PNT000615-PNT0006 15-MNR0012 15-CPA0024 15-0103 17-REF0112 17-02 12 17-0177 17-021117-REF000717-OVN010717-OVN0107 17-020717-020717-CAS0240 17-SHF0160 17-BIN0024 17-OVN005917-CAB012517-GDR001417-SCL002217-GDR001417-BIN0024 17-SNK005417-RGS000317-DPR0039 17-CAB0225 1 7-REF003517-DPR00 0817-DPR0032 17-DPR0032 17-DPR0032 17-DPR0032 17-DPR0032 17-CAB0124 17-CAB0124 18-SHF0054 18-SHF0054 18-SHF0055 18-SHF0055 18-SHF0055 18-SHF005418-SHF005418-SHF005518-BIN002718-SHF005418-SHF0054 18-SHF005518-SHF005518-SHF0055 18-BIN0027 18-CRT0004 18-WPR000718-SNK008318-TBL033618-TBL034718-CAB0299 18-CAB0299 18-CAB029918-SNK025518-SNK006218-SNK025518-CAB029918-TBL034718-CRT000418-GRD000718-GRD0007 18-RKM0094 18-RKM0094 18-RKM0094 18-RKM0094 18-RKM0094 18-RKM009418-SHF009718-SCL004918-SCL004918-SCL004918-CAS0202 18-CAS020218-CAS020218-SHF009718-SHF010918-REF017918-CAS0052 18-CAS005218-CAS027718-BIN0143 18-CAS0300 18-CAS0045 18-CAS004518-WPR000419-0149 19-0149 19-0149 19-BIN005919-SHF009319-SHF0093 19-SHF009319-SHF009319-BIN005919-SCL001619-BIN0049 19-BIN0049 19-BIN0049 19-BIN0049 19-BIN0049 19-BIN0049 19-BIN0049 19-BIN0049 19-BIN0049 19-BIN0049 19-BIN0049 19-BIN004919-BIN004919-BIN004919-BIN004919-BIN0059 19-SHF009319-SHF009319-SHF009319-SHF009319-BIN0059 19-BIN0044 19-SHF0197 19-SHF0197 19-BIN0044 19-DSK0004 20-RKM013420-RKM013420-RKM013420-RKM013420-RKM013420-RKM013420-RKM013420-RKM013420-RKM013420-RKM013420-RKM013420-RKM013420-RKM013420-RKM0134 20-RKM013420-RKM013420-RKM013420-RKM013420-RKM013420-RKM013420-RKM013420-RKM0134 20-RKM0134 20-RKM0134 20-RKM013420-RKM013420-RKM013420-RKM013420-RKM013420-RKM0134 2 1-REF016322-RKM007822-SHF001922-RKM002622-RKM002622-SHF001922-RKM007822-SHF0116 22-RKM007822-SHF011622-RKM007822-SHF011622-RKM0026 22-RKM0026 22-RKM007822-SHF001922-SHF001922-RKM007822-RKM0078 22-RKM0026 22-VND0004 22-ICM0002 22-SHF011622-SNK008122-SHF011622-SHF011622-SNK001022-SHF011622-SNK001022-REF0008 22-SHF011622-OVN0011 22-FYR0010 22-TBL0048 22-TBL0048 22-TBL0173 22-CAB048822-CAB058022-CAB0489 22-CRT005322-TBL0320 22-RKM0163 22-DCR004022-DIV005622-DIV005622-DCR004222-BIN010022-SCL0035 22-REF0057 22-SCL0044 22-DPR0071 22-TBL0323 22-TBL0173 22-CAB0732 22-DPR0093 23-CAS031223-CAS031223-GRD0004 23-GRD0004 23-CAS0326 23-CAS0326 23-WRM0009 23-CAB013023-CAS0318 23-CAS0319 23-CAS032523-CAS0325 23-WRM0009 23-CAS030623-CAS0325 88-WRM0025 23-WRM0009 23-CAS0306 2 3-TBL 058123-CAS037023-CAS037023-CAS037090-WRM0016 23-CAS033623-CAS028190-CAS0407 90-SNK0487 90-SCL0067 90-CAB0953 90-CAB0953 90-SHF0393 90-CAB0955 90-SCL006790-TBL054390-TBL075790-REF020190-REF0201 90-MNR002790-MNR002790-MNR002790-MNR0027 90-RKF0124 24-0162 24-STG0109 24-STG010924-STG010924-STG010900-BIN014700-BIN014700-BIN014724-STG0181 24-STG0182 24-STG0181 24-TBL014824-TBL014824-STG0181 24-STG0182 24-TBL014824-STG0181 24-STG0181 24-TBL014824-STG0181 24-STG018224-TBL014824-STG018124-STG0182 24-STG0181 24-STG0182 24-TBL014824-TBL014824-STG0181 24-STG018224-TBL014824-STG0182 24-STG018124-TBL014824-STG0181 24-TBL014824-STG018224-TBL014824-STG0182 24-STG0182 24-TBL0137 24-TBL0137 24-STG010924-STG010924-STG010924-TBL0722 24-STG018124-STG018224-TBL0148 24-STG018124-STG0181 24-STG0181 24-STG0181 24-STG0182 24-STG018124-STG018224-TBL014824-TBL014824-STG018224-STG018124-TBL0148 24-TBL0722 24-STG0181 24-STG0181 24-STG0181 24-STG018125-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS011325-CAS011325-CAS011325-CAS010925-CAS010925-REF0242 26-0139 26-0120 26-0156 26-0136 26-0137 26-0138 26-0159 26-REF0011 26-WKS0058 26-WKS005726-WKS0057 26-CPA0022 26-RGS0003 26-CPA0020 26-SCN000126-SCN0001 26-CPA0020 26-RGS0003 26-BIN0041 26-DRG0011 26-CPU0001 26-DPR0100 26-SHF026326-DPR0087 26-DPR009026-DPR0087 26-DPR0090 26-DPR0090 26-DPR0090 26-DPR0090 26-BIN0144 26-BIN0144 26-DPR008726-BIN0144 26-DPR0087 26-BIN0144 26-DPR008726-BIN0144 26-DPR008726-DPR009026-DPR0087 26-DPR0090 26-DPR0090 26-DPR0087 26-STD008826-STD008826-DYR0004 26-DYR00042 6-SHF026326-SNK033726-SNK033726-DPR008526-DPR008526-DPR008926-DPR0089 26-DPR0085 26-DPR0085 26-SNK0266 27-011427-013127-CAB002927-CPA001027-CAB002927-STG004727-STG004727-CPA002727-CPA0010 27-CPA002527-CPA0026 27-MNR001327-CPU001427-CPA001527-WKS0063 27-STG0047 27-STG0047 27-PNT0008 27-SCN000627-TRM0001 27-TRM0001 27-ESS000127-PNT0007 27-PNT0004 27-SCN0004 27-CPA0016 27-CPA0014 27-0103 27-011927-012827-0103 27-011927-012827-0103 27-011927-012827-0103 27-011927-012827-0103 27-011927-0103 27-011927-012827-0103 27-011927-012827-0103 27-011927-012827-0103 27-011927-012827-0103 27-011927-012827-0103 27-011927-012827-010327-012827-0103 27-012827-0103 27-011927-012827-0103 27-011927-012827-0103 27-011927-012827-011927-0103 27-011927-012827-STD0004 27-RGS000327-CNV000627-CPA000927-CPA002027-SHF016527-STD0004 27-RGS000327-CPA000927-CPA002027-SHF016527-CNV000627-STD0004 27-CPA000927-RGS0003 27-SHF016527-CPA002027-CNV000627-STD0004 27-RGS000327-CPA0009 27-SHF016527-CPA002027-CNV000627-STD0004 27-RGS000327-CPA000927-CPA002027-SHF016527-CNV000627-STD0004 27-RGS000327-CPA000927-CPA002127-SHF016727-CNV000727-STD0004 27-RGS000327-CPA0009 27-SHF016527-CPA002027-CNV000627-STD0004 27-RGS000327-CPA0009 27-SHF016527-CPA002027-CNV000627-STD0004 27-RGS000327-CPA000927-CPA002027-SHF016527-CNV000627-STD0004 27-RGS000327-CPA000927-CPA002027-SHF016527-CNV000627-STD0004 27-RGS000327-CPA0009 27-SHF016527-CPA002027-CNV000627-STD0004 27-RGS000327-CPA000927-CPA002027-SHF016527-CNV000627-STD0004 27-RGS000327-CPA0009 27-SHF016727-CPA002127-CNV000727-STD0004 27-RGS000327-CPA000927-CPA002027-SHF016527-CNV000627-STD0004 27-RGS000327-CPA000927-CPA002027-SHF016527-CNV000627-STD0004 27-RGS000327-CPA0009 27-SHF016727-CPA002127-CNV000727-STD0004 27-RGS000327-CPA0009 27-SHF016527-CPA002027-CNV000627-0103 27-011927-012827-RGS000327-CPA0009 27-SHF016727-CPA002127-STD0004 27-0103 27-011927-012827-STD0004 27-RGS000327-CPA000927-CPA002027-SHF016527-DCR0017 27-DCR0017 27-0103 27-011927-012827-STD0004 27-RGS0003 27-CPA000927-CPA002027-SHF016527-CNV000627-CPA0034 27-SHF016527-CPA003527-RGS0004 27-STG010027-DCR0017 27-DIV007927-DIV007927-DIV007927-DIV007927-0103 27-011927-012827-STD0004 27-RGS0003 27-CPA000927-CPA002027-SHF016527-CNV000627-0103 27-011927-012827-STD0004 27-RGS0003 27-CPA000927-CPA002027-SHF016527-CNV000627-SCN000827-SCN000827-SCN000827-012827-CAB069727-RGS000427-CPA003927-CPA003527-SCN0008 27-WKS041827-WKS041927-WKS041927-DIV007927-DIV007927-DIV007927-DIV0079 27-DIV0079 27-DIV007927-DIV007927-WKS044127-WKS044127-WKS044127-WKS044127-WKS041827-DCR0017 27-DCR005627-DCR005627-DCR005627-DCR005627-WKS040027-WKS0399 27-WKS039827-WKS039827-RGS0004 27-RGS0004 27-RGS0004 27-RGS000427-CPA003527-SCN000827-DIV0079 27-DIV007927-DIV007927-DIV007927-DIV007927-SCN000827-CPA003527-SCN0008 27-SCN000827-CPA0035 27-CPA003527-CPA003927-CPA003927-CPA003927-CPA003927-FRZ009027-REF0289 27-CAB0831 27-SCN0001 00-PCL000128-CAB029928-CAB029928-SNK025528-SNK006228-TBL033028-SCL006928-MXR003028-OVN0113 28-OVN0154 28-OVN015428-TBL05762 8-TBL 033028-DPR007428-DPR007428-SCL006728-TBL0543CAS0328GRD0004GRD0004GRD0004GRD000428-CAS0 329GRD0004GRD000 4 GRD0004 GRD00 04GRD0004GRD0004 GRD0004GRD0004 31-VND0024 31-VND0025 31-VND0024 31-VND0025 31-VND0024 31-VND0025 31-VND002031-VND002033-RKF002133-RKF002133-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-DSK000433-DSK000433-RKF0009 33-RKF0009 33-RKF0009 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF002133-RKF00213 3-RKF000933-RKF0021 33-RKF002433-CAB002833-RKM0030 33-RKM0030 33-RKM0030 33-RKM0030 33-STD001533-RKM0030 33-RKM0097 33-RKM009733-BIN007033-STD001633-SCN0005 33-PNT0007 33-STG000133-STG000133-BIN0090 33-CPR000233-BIN009033-CPA002333-MNR001233-SCN0002 33-CAB002733-SHF016933-SHF0169 33-RKF0009 33-RKF0009 33-RKF0009 33-RKF0009 33-RKF0009 33-RKF0009 33-RKF0009 33-RKF0009 33-RKF0009 33-RKF0009 33-RKF0009 33-RKF0009 33-RKF0009 33-RKF0009 33-RKF0009 33-RKF0021 33-RKF0021 33-RKF0021 3 3-RKF00093 3-RKF0009 3 3-RKF000933-RKF000933-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF002133-RKF002133-RKF0021 33-RKF0021 33-RKF002133-RKF000933-RKF0021 33-RKF0021 33-RKF0021 33-RKF002133-RKF002133-RKF002133-RKF002133-RKF002133-RKF0021 33-RKF000933-RKF000933-RKF0009 33-RKF0021 33-RKF0021 33-RKF0021 33-WPR0013 33-WPR001333-RKF002133-RKF002133-RKF002133-RKF002133-RKF0021 33-RKF0021 33-RKF0024 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0021 33-RKF0009 33-RKF0009 33-STG024333-STG024333-STG024333-STG024333-STG024333-STG024333-STG024333-STG024333-STG024333-STG0243 33-RKF002133-DSK000433-DSK000433-RKF002133-RKM0108 33-RKM0108 33-RKF0021 34-0186 34-018634-0186 34-0101 34-0193 34-0126 34-0197 34-019834-0194 34-CAB007834-CAB0078 34-PNU0016 34-CAB0033 34-PNT001034-CAB0077 34-SAF0002 34-PNT0009 34-PNT0015 34-MNR001134-RKF004534-SAF0003 34-CAB0034 34-BIN0073 34-RKF0046 34-SCN0007 34-CAB0033 34-CAB0034 34-RKF004734-CAB0034 34-CPA0010 34-MNR0012 34-CPA0024 34-STG000934-STG0009 34-RGS0003 34-STG00063 4-STG004334-RGS0003 34-RGS0003 34-STG0012 34-CAB0138 34-RKF004734-BIN0072 34-BIN0072 34-CAB0034 34-DSK0014 34-CAB009034-MNR001134-STG004734-DSK002734-STG004434-STG004434-STG004434-CAB0089 34-TBL0178 34-RGS000434-CPA0035 34-CPA003434-MNR0023 34-CAB0744 34-CAB0738 34-CAB073834-CAB073834-REF021234-REF021634-REF021234-TBL059834-STG020834-STG020834-WKS0363 34-STG024434-MNR001534-STG0208 34-STG0208 34-WKS0363 34-STG024434-MNR001534-STG0208 34-STG0208 34-STG020834-STG020834-STG0208 34-STG0208 34-REF0216 34-CAB073935-CAB004138-SHF0258 38-SHF0258 38-SHF0258 38-SHF025838-CAB029938-OVN0106 38-OVN010638-RNG009538-RNG009738-FYR0013 38-DPL0006 38-REF0124 38-REF0124 38-TBL035938-FDP000438-FDP0022 38-TBL0481 38-SHF022938-SHF022938-CNV002938-SCL0067 38-SCL0067 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 18-TBL0076 38-OVN012838-OVN014638-RKM0032 38-RKM0032 38-TBL0320 38-FRZ0047 38-SHF025838-RKF007338-SHF025838-SHF025838-SHF025838-DWS002638-DWS0027 38-RKF007338-WPR000238-SNK025338-TBL063138-SNK0357 38-OVN001938-SNK006238-SNK000438-WKS000938-TBL007538-KTL0013 38-KTL0013 38-SHF0054 38-SHF0054 38-SHF005538-SHF005538-SHF0055 38-RKM002838-CRT000438-RKM003238-RKM003238-RKM003238-SHF0054 38-SHF005438-SHF005538-CRT0007 38-CRT0007 38-RKM003238-RKM0032 38-SHF0054 38-SHF005438-SHF005538-KTL001238-RKM0028 38-SHF005438-SHF0054 38-SHF005538-SHF005538-SHF005538-WKS000638-SCL000938-REF004038-RKF0003 38-TBL007638-TBL007638-TBL0076 3 8-FYR00093 8 -RNG005838-REF016138-WPR000438-OVN00353 8-TBL 00763 8 -RKM00323 8-TBL 003138-OVN01323 8-REF006777-SNK025377-SNK033077-CAS009686-RKM0055 86-RKM0055 86-RKM0055 86-RKM0055 86-012686-SNK0004 86-OVN011686-WRM005686-REF016786-CAB085886-REF020186-TBL069386-REF020186-TBL069386-TBL032086-SNK000486-VND000486-SLC000986-TBL060086-TBL0600 86-SNK004886-SHF002686-SHF002686-SLC000586-DSK000486-CAB002786-ICM004486-DPR009386-012986-RKM0152 86-TBL006290-SCL002390-SCL002300-PCL000190-TBL035490-SCL007323-CAS0083 23-CAS0083 05-SHF010605-GRD000705-GRD0007 22-TBL0320 38-TBL0320 86-TBL032005-TBL0319 23-CAS0319 17-REF0112 25-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 06-CAS0374CAS0370CAS0370CAS037003-CAS037003-CAS037023-CAS037023-CAS037023-CAS037018-BIN0143 26-SNK033726-SNK033786-ICM004423-CAS028122-SNK008138-OVN012803-CAS034403-CAS0345CAS032838-SNK0357 10-CAS0317 06-CAS0312 06-CAS0312 06-CAS0312 06-CAS031223-CAS031223-CAS031206-CAS0314 06-CAS031528-CAS0 32903-CAS0327 38-CNV002902-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 14-CAS023214-CAS023214-CAS023214-CAS023214-CAS023214-CAS023214-CAS023314-CAS023314-CAS023377-SNK033026-SNK0266 06-SNK029801-OVN012010-SNK0263CAS247CAS247CAS248CAS248CAS248 02-CAS021402-CAS021402-CAS021402-CAS021402-CAS0215 02-CAS0215 02-CAS0215 02-CAS0215 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 03-SNK025310-SNK025338-SNK025377-SNK025307-SNK015218-SNK0255 18-SNK025518-SNK0255 28-SNK025505-CAS009001-OVN001601-KTL0004 22-ICM000201-DWS000701-SNK000401-SNK000401-SNK000405-SNK000438-SNK000486-SNK0004 86-SNK000422-SNK001022-SNK001001-SNK001601-SNK003201-SNK003386-SNK004810-SNK005017-SNK0054 01-KTL000518-SNK0062 18-SNK0062 28-SNK006238-SNK006238-OVN003538-KTL001238-KTL0013 38-KTL001318-SNK008303-SNK016322-REF0008 18-CAS0052 18-CAS0052 02-CAS0055 02-CAS0055 02-CAS0055 04-CAS00550 2-CAS0056 02-CAS0 0 5 6 04-CAS00563 8 -RNG005815-0109 18-SHF010924-STG0109 24-STG010924-STG010924-STG010924-STG010924-STG010924-STG010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010907-SHF012207-SHF012207-SHF0122 07-SHF012207-SHF012207-SHF012207-SHF012207-SHF0122 07-SHF0122 07-SHF0122 22-DPR0093 86-DPR009318-BIN0152 38-OVN014613-SNK033226-SNK033726-SNK033726-SNK033726-SNK033786-ICM004486-ICM004422-SNK008122-SNK008138-OVN012838-OVN012805-DPR0084 38-SNK035738-SNK035713-SNK033213-SNK033218-ICM0042 01-OVN012001-OVN012010-SNK026310-SNK026303-SNK025310-SNK025338-SNK025377-SNK025303-SNK025310-SNK025338-SNK025377-SNK025307-SNK015207-SNK015218-SNK0255 18-SNK025518-SNK0255 28-SNK025518-SNK0255 18-SNK025518-SNK0255 28-SNK025515-0109 18-SHF010924-STG0109 24-STG010924-STG010924-STG010924-STG010924-STG010924-STG010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010915-0109 18-SHF010924-STG0109 24-STG010924-STG010924-STG010924-STG010924-STG010924-STG010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010905-CAS009505-CAS009505-CAS0095 05-CAS0096 05-CAS0096 05-CAS009605-CAS0096 05-CAS009605-CAS0096 06-CAS0096 77-CAS0096 10-CAS0239 10-CAS023910-CAS023910-CAS023912-SHF0239CAS247CAS247CAS247CAS247 CAS0328CAS032828-TBL03302 8-TBL 033077-SNK033077-SNK033001-DPR0001 01 -D PR0001 05-DPR0001 01-OVN001601-OVN001601-KTL000401-KTL0004 22-ICM000222-ICM000201-DWS000701-DWS000701-SNK000401-SNK000401-SNK000405-SNK000438-SNK000486-SNK0004 86-SNK000401-SNK000401-SNK000401-SNK000405-SNK000438-SNK000486-SNK0004 86-SNK000422-SNK001022-SNK001022-SNK001022-SNK001001-SNK001601-SNK001601-SNK003201-SNK003201-SNK003301-SNK003386-SNK004886-SNK004810-SNK005010-SNK005006-SNK029806-SNK029817-SNK005417-SNK0054 18-SNK0062 18-SNK0062 28-SNK006238-SNK006218-SNK0062 18-SNK0062 28-SNK006238-SNK006207-DPR0025 38-OVN003538-OVN003501-REF003101-REF003101-KTL000501-KTL000538-KTL001238-KTL001238-KTL0013 38-KTL001338-KTL0013 38-KTL0013 17-DPR0039 18-SNK008318-SNK008303-SNK016303-SNK01633 8 -RNG00583 8 -RNG005838-OVN014638-OVN014686-OVN011602-CAS0104 02-CAS0104 03-CAS010403-CAS010404-CAS010404-CAS0104 10-CAS004810-CAS0048 02-CAS0055 02-CAS0055 02-CAS0055 04-CAS005502-CAS0055 02-CAS0055 02-CAS0055 04-CAS005505-CAS009005-CAS009005-CAS009505-CAS009505-CAS0095 05-CAS009505-CAS009505-CAS0095 05-CAS0096 05-CAS0096 05-CAS009605-CAS0096 05-CAS009605-CAS0096 06-CAS0096 77-CAS009605-CAS0096 05-CAS0096 05-CAS009605-CAS0096 05-CAS009605-CAS0096 06-CAS0096 77-CAS0096 14-CAS0100 14-CAS0100 14-CAS0100 14-CAS0100 03-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010514-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS027714-CAS027714-CAS027714-CAS027718-CAS027725-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS011325-CAS011325-CAS011301-CAS014901-CAS014901-CAS015225-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 25-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 18-CAS0202 18-CAS020218-CAS020205-CAS021906-CAS037406-CAS0374CAS0370CAS0370CAS037003-CAS037003-CAS037023-CAS037023-CAS037023-CAS0370CAS0370CAS0370CAS037003-CAS037003-CAS037023-CAS037023-CAS037023-CAS037023-CAS028123-CAS0281CAS0328CAS0328CAS0328CAS032828-CAS0 32928-CAS0 32903-CAS0327 03-CAS0327 10-CAS031710-CAS0317 06-CAS0312 06-CAS0312 06-CAS0312 06-CAS031223-CAS031223-CAS031206-CAS0312 06-CAS0312 06-CAS0312 06-CAS031223-CAS031223-CAS031206-CAS031406-CAS0314 06-CAS031506-CAS0315 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 14-CAS023214-CAS023214-CAS023214-CAS023214-CAS023214-CAS023214-CAS023214-CAS023214-CAS023214-CAS023214-CAS023214-CAS023214-CAS023314-CAS023314-CAS023314-CAS023314-CAS023314-CAS0233CAS247CAS247CAS247CAS247CAS247CAS247CAS247CAS247CAS248CAS248CAS248CAS248CAS248CAS248 02-CAS021402-CAS021402-CAS021402-CAS021402-CAS021402-CAS021402-CAS021402-CAS021402-CAS0215 02-CAS0215 02-CAS0215 02-CAS0215 02-CAS0215 02-CAS0215 02-CAS0215 02-CAS0215 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 02-CAS0216 22-REF000822-REF000822-REF000822-REF000822-REF000822-REF0008 22-ICM000222-ICM000222-ICM000222-ICM0002 10-CAS004810-CAS0048 10-CAS004810-CAS0048 18-CAS0052 18-CAS005218-CAS0052 18-CAS0052 02-CAS0055 02-CAS0055 02-CAS0055 04-CAS005502-CAS0055 02-CAS0055 02-CAS0055 04-CAS005502-CAS0055 02-CAS0055 02-CAS0055 04-CAS005502-CAS0055 02-CAS0055 02-CAS0055 04-CAS00550 2-CAS0056 02-CAS0 0 5 6 04-CAS00560 2-CAS0056 02-CAS0 0 5 6 04-CAS005610-REF004210-REF004210-REF004205-CAS009005-CAS009005-CAS009005-CAS009005-CAS009505-CAS009505-CAS0095 05-CAS009505-CAS009505-CAS0095 05-CAS009505-CAS009505-CAS0095 05-CAS009505-CAS009505-CAS0095 05-CAS0096 05-CAS0096 05-CAS009605-CAS0096 05-CAS009605-CAS0096 06-CAS0096 77-CAS009605-CAS0096 05-CAS0096 05-CAS009605-CAS0096 05-CAS009605-CAS0096 06-CAS0096 77-CAS009605-CAS0096 05-CAS0096 05-CAS009605-CAS0096 05-CAS009605-CAS0096 06-CAS0096 77-CAS009605-CAS0096 05-CAS0096 05-CAS009605-CAS0096 05-CAS009605-CAS0096 06-CAS0096 77-CAS0096 14-CAS0100 14-CAS0100 14-CAS0100 14-CAS0100 14-CAS0100 14-CAS0100 14-CAS0100 14-CAS0100 25-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 25-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 25-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 25-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 14-CAS0102 02-CAS0104 02-CAS0104 03-CAS010403-CAS010404-CAS010404-CAS0104 02-CAS0104 02-CAS0104 03-CAS010403-CAS010404-CAS010404-CAS010403-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010503-CAS010514-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS010814-CAS027714-CAS027714-CAS027714-CAS027718-CAS027714-CAS027714-CAS027714-CAS027714-CAS027718-CAS027725-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS010925-CAS011325-CAS011325-CAS011325-CAS011325-CAS011325-CAS011301-CAS014901-CAS014901-CAS014901-CAS014901-CAS014901-CAS014901-CAS014901-CAS014901-CAS014901-CAS014901-CAS014901-CAS014901-CAS015201-CAS015210-CAS0239 10-CAS023910-CAS023910-CAS023910-CAS0239 10-CAS023910-CAS023910-CAS023905-CAS029910-CAS029910-CAS029910-CAS029903-CAS0182 03-CAS0182 23-CAS0083 23-CAS0083 03-CAS0298 02-CAS0298 03-CAS0298 03-CAS0298 03-CAS0298 03-CAS0298 03-CAS0298 10-CAS0298 05-CAS029810-CAS0298 10-CAS0298 18-CAS0202 18-CAS020218-CAS020218-CAS0202 18-CAS020218-CAS020205-CAS021905-CAS021903-FRZ0058CAS0356CAS0356CAS0356CAS0356 03-CAS0274 03-CAS0274 05-CAS0274 10-CAS0274 03-CAS0296 38-RNG009538-OVN013238-OVN0106 38-OVN010601-OVN001601-OVN001601-OVN001601-OVN001638-OVN001938-KTL0013 38-KTL001338-KTL0013 38-KTL001338-KTL0013 38-KTL001338-KTL0013 38-KTL0013 22-FYR001022-FYR001022-FYR001001-DWS000701-DWS000701-DWS000701-DWS000701-KTL000401-KTL000401-KTL000401-KTL0004 3 8 -RNG00583 8 -RNG00583 8 -RNG00583 8 -RNG005838-FYR0013 38-RNG009538-RNG009538-RNG009738-OVN0106 38-OVN010638-OVN0106 38-OVN010638-KTL0013 38-KTL001338-KTL0013 38-KTL001338-KTL0013 38-KTL001338-KTL0013 38-KTL001338-KTL0013 38-KTL001338-KTL0013 38-KTL001338-KTL0013 38-KTL001338-KTL0013 38-KTL001322-FYR001022-FYR001022-FYR001022-FYR0010 3 8 -RNG00583 8 -RNG00583 8 -RNG00583 8 -RNG00583 8 -RNG00583 8 -RNG00583 8 -RNG00583 8 -RNG005838-OVN001938-OVN001922-FYR001022-FYR001022-FYR001022-FYR001022-FYR001022-FYR001022-FYR001022-FYR0010 01-KTL000401-KTL000401-KTL000401-KTL000401-KTL000401-KTL000401-KTL000401-KTL0004 01-OVN001601-OVN001601-OVN001601-OVN001601-OVN001601-OVN001601-OVN001601-OVN001638-KTL001238-KTL001238-KTL001238-KTL001238-FYR001338-FYR0013 00-GRD000400-GRD000423-CAS037023-CAS037023-CAS037023-CAS0370 12 L.F. GROC. 18" BASE 56 LF OF PLUGMOLD39 L.F. GROC. 16" BASE SCALE STATIONDUNNAGE/TRAY STORAGETRAY STORAGE/LOCKERS GRIND/SLICE4 l.f.CREAMCHEESECASE10 DOORS 20 DOORS 52 L.F. RDR CASE 36 L.F. DAIRY 20 L.F. DAIRY (ON3.5UM) 20 L.F. DAIRY (ON3.5UM)6 L.F. DAIRY(ON3.5UM)6 L.F. DAIRY(ON3.5UM)56 L.F. GM 18" BASE20 L.F. NATURES 14" BASE24 L.F. GROC. 24" BASE24 L.F. GROC. 24" BASE24 L.F. GROC. 24" BASE24 L.F. GROC. 24" BASE64 L.F. GROC. 24" BASE64 L.F. GROC. 20" BASE68 L.F. GROC. 20" BASE68 L.F. GROC. 20" BASE68 L.F. GROC. 20" BASE72 L.F. GROC. 20" BASE72 L.F. GROC. 24" BASE72 L.F. GROC. 26" BASE48 L.F. GROC. 32" BASE120 L.F. GROC. 26" BASE20 L.F. GROC. 24" BASE24 L.F. GROC./BEER 20" BASE24 L.F. GROC./BEER 20" BASE24 L.F. GROC./BEER 20" BASE24 L.F. GROC./BEER 20" BASE20 L.F. GROC. 26" BASE20 L.F. GROC. 24" BASE20 L.F. GROC. 20" BASE52 L.F. GROC. 20" BASE52 L.F. GROC. 24" BASE44 L.F. GROC. 14" BASE44 L.F. GROC. 14" BASE52 L.F. GROC. 20" BASE68 L.F. GROC. 20" BASE12 L.F. SHELVING 6 DOORS FROZENSEAFOOD (ONRZ) BA216 L.F. READY TO EATSEAFOOD (03.5UM)8 LF KOSHER(OHMH8) BA216 LF DELI SHORTCUTS(OHMH8) BA212 L.F. G.M. 24" BASE 12 L.F. GROC. 24" BASE 36 L.F. GROC. 24" BASE24 L.F. G.M. 20" BASE24 L.F. GROC. 20" BASE24 L.F. GROC. 20" BASE12 L.F. GROC.20" BASE12 L.F. G.M.20" BASE8 L.F. GROC.20" BASE64 L.F. G.M. 20" BASE68 L.F. GROC. 24" BASE68 L.F. GROC. 20" BASE52 L.F. GROC. 20" BASE52 L.F. GROC. 20" BASE52 L.F. GROC. 14" BASE44 L.F. GROC. 14" BASE44 L.F. GROC. 14" BASE52 L.F. GROC. 14" BASE52 L.F. G.M. 18" BASE52 L.F MAGAZINES28 L.F. GROC. 18" BASE12 L.F. G.M.18" BASE16 L.F. HBC 18" BASE56 L.F. GROC. 20" BASE20 L.F. HBC 18" BASE20 L.F. HBC 16" BASE20 L.F. BEER CASE (05DM) BA220 L.F. GROC. 30" BASE32 L.F. DAIRY (ON3.5UM) 32 L.F. DAIRY (ON3.5UM)6 L.F. DAIRY(ON3.5UM)6 L.F. DAIRY(ON3.5UM)12 L.F. SERVICESCASES PSGF-SSC8 L.F. FISHCASE (PTDSF)BA224 L.F. SERVICES CASES PSGF-SSC8 L.F. MEAT CASE(02UM)8 L.F. PREPARED FOODS (03.5UM)16 L.F. SERVICE CASES(DLP) BA264 L.F. BULK CASESW/MISTERS & MIRRORS (ON5DM)(FIRST 16 L.F. CUT FRUIT)72 L.F. CONVENIENCE CASE(ON5DM)24 L.F. PREPARED FOODS(03.5UM)24 L.F. BAKERY(03.5UM)20 L.F. PRODUCE CASE(OUM) BASE HT 5", FINISHED BACK16 L.F. BERRY CASES(O3.5UM) 7" BASEFINISHED BACK12 L.F. PRODUCE CASE (PTJC) SMART SNACKING 4 L.F. JUICE MULTI-DECK CASE (ONNSA) BASE HT 17", FINISH BACK 24 L.F. BULK CASESW/MISTERS & MIRRORS (ON5DM)22 DOOR FROZEN CASE (ONRZ)22 DOOR FROZEN CASE (ONRIZ)22 DOOR FROZEN CASE (ONRIZ)22 DOOR FROZEN CASE (ONRZ)2 DOOR FROZEN CASE (ONRZ) 3 DOOR FROZEN CASE (ONRZ) 8 L.F. DAIRY (ON5DM) 2 DOOR FROZEN CASE (ONRZ) 3 DOOR FROZEN CASE (ONRZ)2 DOOR FROZEN CASE (ONRZ) 2 DOOR FROZEN CASE (ONRZ) 3 DOOR FROZEN CASE (ONRZ) 2 DOOR FROZEN CASE (ONRZ)20 DOOR FROZEN CASE (ONRZ)20 DOOR FROZEN CASE (ONRIZ)20 DOOR FROZEN CASE (ONRIZ)12 DOOR FROZEN CASE (ONRZ)8 L.F. DAIRY (ON5DM)3 DOOR FROZEN (ONRZ) CASE 2 DOOR NATURES (ONRZ)(HSO4)4 L.F. MEAT(O2.5UM6) 6 L.F. MEAT (OMCA)4 L.F. DELI16 L.F. MEAT (OHMH) CHEESE 4 L.F. ENTERTAINING CHEESE CASE ENTERAINING CHEESE CASE 6 L.F. CHEESE (02.5UMA)12 L.F. CHEESE (HSO)4 L.F. CHEESE (02.5UM)8 L.F. CHEESE (UMA)8 L.F. CHEESE (HSO)12 LF SERVICE CASE (DLPT) 6 L.F. PRODUCE (UMA) 6 L.F. PRODUCE (UMM) 6 L.F. PRODUCE (UMM) 6 L.F. PRODUCE (UMM)20 L.F. COMMERCIAL BAKERY20 L.F. COMMERCIAL BAKERY20 L.F. COMMERCIAL BAKERY20 L.F. COMMERCIAL BAKERY20 L.F. COMMERCIAL BAKERY20 L.F. NATURES 18" BASE24 L.F. NATURES 18" BASE24 L.F. NATURES 18" BASE24 L.F. NATURES 18" BASE24 L.F. NATURES 18" BASE24 L.F. NATURES 18" BASE24 L.F. NATURES 18" BASE20 L.F. NATURES 18" BASE20 L.F. NATURES 18" BASE20 L.F. NATURES 18" BASE20 L.F. NATURES 18" BASE20 L.F. NATURES 18" BASE20 L.F. NATURES 18" BASE20 L.F. NATURES 20" BASE8 DOOR FROZEN CASE (ONRZ)12 DOORS MED. TEMP NATURES(ONRB) BA236 L.F. G.M. 18" BASE36 L.F. G.M. 18" BASE60 L.F. ELIPTIPAR LIGHTING60 L.F. G.M. 18" BASE56 L.F. G.M. 18" BASE4 L.F. G.M. 18" BASE60 L.F. GROC. 24" BASE60 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE60 L.F. GROC. 24" BASE60 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE16 L.F. G.M. 18" BASE18" BASE 4 L.F. G.M. 24 L.F. CHEESE (OHM) 28 L.F. MEAT (OHMH) OAK 40 L.F. MEAT (OHMH) OAK56 L.F. H&W (COSMETICS) 16" BASE24 L.F. H&W 16" BASE24 L.F. H&W 18" BASE24 L.F. H&W 16" BASE24 L.F. H&W 16" BASE24 L.F. H&W 16" BASE24 L.F. H&W 16" BASE24 L.F. H&W 16" BASE24 L.F. H&W 16" BASE20 L.F. H&W 16" BASE20 L.F. H&W 16" BASE20 L.F. H&W 16" BASE20 L.F. H&W 16" BASE20 L.F. H&W 16" BASE20 L.F. H&W 16" BASE20 L.F. H&W 18" BASE20 L.F. H&W 16" BASE8 L.F. H&W16" BASE8 L.F. H&W16" BASE20 L.F. NATURES 18" BASE20 L.F. NATURES 18" BASE24 L.F. H&W 18" BASE24 L.F. H&W 18" BASE24 L.F. H&W 18" BASE24 L.F. H&W 18" BASESINFULZOYASUPPLIESSUPPLIES STORE STORE TABLE KETTLE REF. PREP TABLEA/C UNITPHONEGRINDERSCULLIGAN WATER CANS 48X40 PALLET 48X40 PALLET MECH.MECH.MECH.PRODUCT HANDWASHFILTERSHANDWASHCABWASH RINSE SANITIZEICE BINFREESTYLETABLE 86-RKM0020 86-RKM002038-SNK025538-SNK006238-CRT000438-CRT000438-CRT000438-SHF005538-SHF005538-SHF005538-SHF0055TABLE34-0192 34-0124 34-0185 34-CPA002034-CAB002934-WKS0324 FRONT COUNTER180" X 40" VENDOR GMBULKVENDOR VENDOR VENDOR VENDOR VENDOR GMDEMONATURE STORE SUPPLIES STORE SUPPLIES BAKERY VENDOR BULK STORE SUPPLIES PRODUCEREFRIG. TANK STORAGE PRODUCEPRODUCEPRODUCE BAKERY RACK STORAGE NIGHT GROCERY DAY GROCERY GROC.GROC.GROC.CHARGING STATIONS (2)CHARGING STATIONS (2)CHARGING STATIONS (2)BAKERY PRODUCEPRODUCEPRODUCEPRODUCEPRODUCEPRODUCEPRODUCE PRODUCEPRODUCEPRODUCEGMGMGMGROC. GROC.GROC.GROC.GROC.GROC.GROC.GROC.GROC.GROC.GROC. GROC. STORE SUPPLIES STORE SUPPLIESBULKNATURE STORE STORE PREPARED PREPARED PREPARED CARDBOARD STORAGE HANDI-MAN AREAGROC.RECYCLING STORAGE CARDBOARD STORAGE GROC.GROC.GROC.GROC.GROC. SUPPLIESSUPPLIES GM PRODUCEPRODUCESTORE SUPPLIES STORE SUPPLIES STORE SUPPLIES STORE SUPPLIES STORE SUPPLIES STORE SUPPLIESSTORE SUPPLIES STORE SUPPLIES STORE SUPPLIES DAIRY BULK FROZEN GMGMGM SHRINK SCALE PRODUCESUPPLIES STORE GM REC CABINET BENCHTRASHRECREC CARDBOARD STORAGE 33-CAB002728-TBL0581 6 7 8 9 10 11 12 13 14 15 16 17 191 3 4 5 182 24 21 22 23 25 26 27 28 29 30 31 322027-CNV000727-CNV000627-011927-CNV001827-SCN0008PNU-DROP27-CNV0032ADA ADA ADA MERCHOPP MERCH OPPPFSSSTANCHION/BARRIERBELOW STAIR LANDING,BY STORE 30x48WC SPACE 30x48WC SPACE CAB COLD HOT COLD COLD COLD VEGGIE COLD SALADS WING BAR HOT WINGS OF LIFE SALAD STATION HOT CAB CAB CAB CAB CAB CAB 23-GRD0004 23-GRD0004 23-CAS0169 FREESTYLE 22-OVN013922-TBL032022-DCR004022-OVN0140 22-RKM0161 22-CAS0274 20-RKM0134 19-0157 18-SHF005518-SHF005518-CRT0004 18-GRD000718-CAS0169 TABLE17-DPR002617-DPR002617-DPR003317-DPR003317-DPR003317-DPR003317-DPR0033ROLL RACK 13-TBL0604 GM WOWBINVENDORCASEDVDRACKVENDORCASE VENDORCASE MERCHANDISEDISPLAYGIFT CARDSWOWBINWOWBINWOWBINWOWBIN36 L.F. G.M. 18" BASEHBC BRIGGS FEATHERBELLEBATH SALTS WOW WOW WOW WOW WOW WOW WOW WOW TEACHINGTABLE TEACHINGTABLE TEACHINGTABLE TEACHINGTABLE TEACHINGTABLE TEACHINGTABLE CHEESE 3'- 0 " BUTCH BLKTABLE 36"x48" 07-MNR0015 07-CAB0378 07-CAB017407-PNT0010\8 L.F. SERVICEKOSHER (DPL) BA224 L.F. SERVICEDELI (DPL) BA212 L.F. GRAB N GODELI (03UM)7" BASE(FINISH BACK)06-CRT000406-CRT000406-CAS0096SERIAL #: 1073168 SERIAL#: 1073169 SOLID VIEWCLEAR VIEW05-CRT0004 05-CRT0004 05-CRT0004 05-CRT0004 05-CRT0004 05-CRT0004 05-CRT0004 05-CRT0004 05-CRT000405-SHF005505-SHF0055 05-SHF0055 05-SHF0055 05-SHF005505-SHF0055FAMILY PACK/PALLET FAMILY PACK/PALLET FAMILY PACK/PALLET FAMILY PACK/PALLET FAMILY PACK/PALLET FAMILY PACK/PALLET FAMILY PACK/PALLET FAMILY PACK/PALLET FAMILY PACK/PALLET FAMILY PACK/PALLET FAMILY PACK/PALLET FAMILY PACK/PALLET LOCKERSCRATESCRATES CRATESCRATESCRATESCRATES CRATES CRATES CRATES CRATES MERCHANDISING OPPORTUNITY 03-SCL0061 03-TBL0162 03-SCL006103-CAS0182 03-TBL0285 03-TBL016203-TBL0162 03-DISPENSER 03-TBL0162 03-TBL0162 03-SCL006103-SCL0061 03-SCL006102-GRD0004CRATESPACKAGED BREAD PACKAGED BREADPROOF BOXESIN-STORE BAGELS01-SHF005501-RKM0004 01-RKF00070 1-R KM0016 0 1-R KM0016 0 1-R KM0016 0 1-R KM0016 0 1-R KM0016 0 1-R KM0016 01-RKM0 016 0 1-R KM0016 0 1-R KM0016 01-RKM0 016 0 1-R KM0016 01-SHF005501-SHF005501-CRT0003 01-BIN0001 0 1-RKM00210 1-RKM002101-TBL0083CART WASH DAIRY FLORAL DELI COOLER BAKERY FREEZER MEAT MEATPREP MEATFISHDELI COLD CUTSCHEFS CASEBAKERY PREP SUSHI MEAT PREP SCULLERY MEAT COOLER FIRE EXIT FIRE EXIT STAIRS FISH FREEZERFISH COOLER COOLER FREEZER SCULLERY36%%176-38%%176 PIZZA COOLER STAIRS SUB SHOP36%%176-38%%176 FIN. PRODUCT 36%%176-38%%176 RAW PRODUCT MEETING ROOM MECH. FIRE EXIT FIRE EXIT PRODUCE COOLER FIRE EXIT FIRE EXIT FIRE EXIT FIRE EXIT FIRE EXIT FIRE EXIT BEVERAGE COOLER GROCERY MERCHANDISING FROZEN FREEZER COUNTRY GROCER ELEC. ROOM G.M. / GROCERY RECEIVING COFFEE PIZZA BEANS RESTROOMS WOMENMEN ATM MECH. CANOPY ENTRANCE ELEV.MECH. PHARMACY DRY CLEANING STRG.ENCLOSED WINDSCREEN PLANTER BOTTLE RETURN STORAGE AMSA ENTRANCE F.E. MGR. ACCOUNTING COMPUTER RM. PHONE CANOPYSECURITY CHECKOUTS HOME & ENTERTAINMENT SEASONAL FROZEN FOOD NATURE'S HEALTH & WELLNESS DAIRY REST. DAIRY COOLER MAINT. STR. RECV. STR. RECV. VENDOR DOCK CATERING CENTRAL CUTTING STATION STAGING COOLER SOUP ASIAN BAKERY COMMERCIAL SUB SEATING (45 SEATS) OFFICE OFFICE STORAGE OFFICE OFFICE INSTACART HOMETOWN MERCH. ELECTRIC SWITCH GEAR TRANSFORMER MDP 1-1/2" SITE LIGHTINGELECTRICAL SERVICETELEPHONE ENTRANCEEQUIP RACKS ICOT ICOT COMPUTER PHONE BOARDSOUND SEWER MAIN3" IRRAGATION LINESTROM OUTLETSTORM OUTLETSTORMCOMPACTOR HYDRAULICS EYE WASHSTATIONEYE WASHSTATIONEYE WASHSTATIONWASTE OIL TANK GAS SERVICE WATER MAIN CO2 TANK TANKWATER BRINESOFTENERSTORAGE300 GAL.BOILER TANK BOILER COOLERPITMECH. UP UP UPSLOPESLOPESLOPE8"8"8" 8" SLOPESLOPE SLOPEDOWNSPRINKLERPLATFORMDOWNDOWNDOWNDOWN DOWNDOWNDOWNDOWNCIRCUIT LEGEND CIRCUIT 1BCIRCUIT 2B CIRCUIT 2A CIRCUIT 1A CIRCUIT 1CCIRCUIT 2CRX I/O NETWORK FIELD VERIFY LOCATION MULTIPLE 22/2 BELDEN FROM HOOD SYSTEMS SEE DWG. C-06 AIR COMP. BX-9 BX-9 8R0-9 8R0-10 8IO-4 8IO-5 4AO-1 16AI-3 BX-10 8IO-1 16IO-2 8RO-2 8RO-5 BX-916AI-7 8RO-7 8IO-1 8IO-2 8RO-3 SEWAGE EJECTOR PUMP SYSTEM BX-9 RH-1 RH-5RH-2 RH-3 RH-4 (4) 120/1/60 (6) 120/1/60 (6) 22/2 BELDEN 8761 (6) 22/2 BELDEN 8761 (2) #14/2 FUSED (4) #14/2 FUSED 120V (2) #14/2 FUSED 120V #14/2 FUSED120V #14/2 FUSED 120V 120V (2) #14 FUSED #14/2 FUSED 120V(4) #14/2 FUSED120V(2) #14 FUSED PMAC CAFE' PANEL #10 208VAC DISC. DISC.DISC. DISC. DISC.G010OC-6 (2) #14 TO OUTPUT 5-5 120V/1/60 RX-5 CONTROLLER RX-4 CONTROLLER RX-7 CONTROLLER RX-6 CONTROLLER RX-3 CONTROLLER RX-2 CONTROLLER BX-1 CONTROLLER RX-8 CONTROLLER #14 TO 1A DEFROST PANEL BX-9 CONTROLLER (8) #18 CONDUCTORS TO CAFE' PANEL (8) #18 CONDUCTORS TO CAFE' PANEL CM NET RS485 18/3 WEST PEN D303 # 14/2 FUSED 120V T O R E M O T E C A F E ' P A N E L (8) #18 CONDUCTORS MOUNT UNDERPOWER HOUSELOCATED IN STOREPANELLIGHTING (2)#14/2FUSED120VMULTIPLE 22/2 BELDEN FROM HOOD SYSTEMS G010O G4106E LIGHTING PANEL MOUNT UNDERPOWER HOUSE#14/2 FUSED 120V 120V14/3 TOBOI LERSBX-10 8IO-3 16AI-4 8RO-4 8RO-6 (8) #18 CONDUCTORS TO CAFE' PANEL #14/2 FUSED 120V BX-10 CONTROLLER VESTIBULE HEAT & AIRDOOR PANEL LOCATED IN MECH. RM. (6) #18 24V TO AIR DOOR PANEL 120/1/60 FEED REMOTE PANEL BX-9 BX-9 8R0-8 8D0-1 BX-9 40,000 LBSEDS-A 15,442 LBS AC-2 34,000 LBS BX-9 16AI-6 8RO-6 AC-3 AC-7 AC-6 11,100# AC-5 1222# 752 LBS AC-8 HR-1 1C/2C CONTROLLER15,442 LBS P/H-CP/H-B BRX-154A 3990# BRX-154A 3990# AC-9 10 TON AC-4 1222# 10 TON AD-1 10 TON 5 TON 1222#752# 1300# 5 TON 752# P/H-A AC-1 BRX-118A 3190# BRX-118A 3190# BRX-052A 1580# 19 CONTROL LINK CASE CONTROLLERS 1A LOOP 1 (FROZEN) SET JUMPERS TO TERMINATE ON CL-CD 1A06-04 32 CONTROL LINK CASE CONTROLLERS 1B LOOP 2 (PREPARED/PRODUCE) SET JUMPERS TO TERMINATE ON CL-CD 1B24-03 1B RS485 CASE CONTROL NETWORKS (FIELD WIRED)4 CONTROL LINK CASE CONTROLLERS 2B LOOP 2 (DAIRY/BEER) SET JUMPERS TO TERMINATE ON CL-CD 2B27-02 2B RS485 CASE CONTROL NETWORKS (FIELD WIRED) CONTROL WIRING I/O NETWORK RX-1A RS485 NETWORK RX-1B RS485 NETWORK RX-2B RS485 NETWORK RX-2 (1A) RS485 CASE CONTROL NETWORKS (FIELD WIRED) WIRING BY OTHERS 12 CONTROL LINK CASE CONTROLLERS 2B LOOP 1 (DELI/SUSHI) SET JUMPERS TO TERMINATE ON CL-CD 2B28-01 FACTORY PROVIDED TYPICAL STORE TCP / I/P ETHERNET CONNECTION TCP/IP EXPANSION CARDS POWER INTERFACE BOARD COM2B COM2A COM4B COM4A COM6 RX-2 (1A) CONTROLLER (RX-300) 24V POWERHOUSE A TCP/IP EXPANSION CARDS POWER INTERFACE BOARD COM2B COM2A COM4B COM4A COM6 RX-4 (1B) CONTROLLER (RX-300) POWERHOUSE B TCP/IP EXPANSION CARDS POWER INTERFACE BOARD COM2B COM2A COM4B COM4A COM6 RX-5 (2B) CONTROLLER (RX-300) FACTORY PROVIDED RX-4 (1B) I/O NETWORK FACTORY PROVIDED RX-2 CONTROLS RACK 1A RX-2 CONTROLS BOARDS 16AI - 1-5 8RO - 1-6 4AO - 1 RX-2 (1A) RACK A RX-2 (1A) BOARD ESR8 - 1 IN OUT IN RX-4 (1B) CONTROLS RACK 1B RX-4 (1B) BOARDS 16AI - 1-8 8RO - 1-11 MRLDS PANEL 16 CHANNEL RX-4 (1B) BOARD IN OUT FIELD PROVIDED RX-2 (1A) I/O NETWORK RX-2 (1A) I/O NETWORK RX-3 (1B) I/O NETWORK 24V 24V 24V 24V 24V 24V TYPICAL STORE TCP / I/P ETHERNET CONNECTION TYPICAL STORE TCP / I/P ETHERNET CONNECTION 4* CONTROL LINK CASE CONTROLLERS 2A LOOP 1 (CENTRAL PREP) SET JUMPERS TO TERMINATE ON CL-CD 2A48-01 (SEE M401 NOTE) 2A RS485 CASE CONTROL NETWORKS (FIELD WIRED) FACTORY PROVIDED TYPICAL STORE TCP / I/P ETHERNET CONNECTION TCP/IP EXPANSION CARDS POWER INTERFACE BOARD COM2B COM2A COM4B COM4A COM6 RX-3 (2A) CONTROLLER (RX-300) 24V RX-3 CONTROLS RACK 2A RX-3 CONTROLS BOARDS 16AI - 1-8 8RO - 1-12 RX-3 CONTROLS BOARDS RACK A RX-3 CONTROLS BOARDS BOARD ESR8 - 2&3 IN OUT IN RX-3 (2A) I/O NETWORK RX-2 (1A) I/O NETWORK 24V 24V 30 CONTROL LINK CASE CONTROLLERS 2A LOOP 2 (FROZEN/NATURES) SET JUMPERS TO TERMINATE ON CL-CD 2A03-03 2A RS485 CASE CONTROL NETWORKS (FIELD WIRED) 2B RS485 CASE CONTROL NETWORKS (FIELD WIRED) RX-5 (2B) I/O NETWORK RX-5 (2B) CONTROLS RACK 2B RX-5 (2B) BOARDS 16AI - 1-6 8RO - 1-8 IN OUT 24V 16 CONTROL LINK CASE CONTROLLERS 2C LOOP 2 (PRODUCE/DAIRY/NATURES) SET JUMPERS TO TERMINATE ON CL-CD 2C03-04 RX-1C/2C RS485 CASE CONTROL NETWORKS (FIELD WIRED) 5 CORE SENSE COMPRESSORS RX-1C/2C LOOP 1 (RACK C) TCP/IP EXPANSION CARDS POWER INTERFACE BOARD COM2B COM2A COM4B COM4A COM6 RX-6 (1C/2C) CONTROLLER (RX-300) FACTORY PROVIDED 208V FROM PH PANEL TYPICAL STORE TCP / I/P ETHERNET CONNECTION RX-5 (2B) I/O NETWORK RX-6 C CONTROL PANEL RACK C RX-6 C BOARD MultiFlex 168 - 1-5 IN OUT 24V RRLDS PANEL 8 CHANNEL RX-6 (C) BOARD120V 120V RX-C RS485 NETWORK SYSTEM NETWORK ARCHITECTURE NAME SERVICE TYPE I/P ADDRESS BX-1 ALARM BX-300 10.71.3.25 RX-2 RACK 1A RX-300 10.71.3.26 RX-3 RACK 2A RX-300 10.71.3.27 RX-4 RACK 1B RX-300 10.71.3.28 RX-5 RACK 2B RX-300 10.71.3.29 RX-6 AC-1 RX-300 10.71.3.30 RX-7 AC-2 RX-300 10.71.3.31 RX-8 AC-3 RX-300 10.71.3.32 BX-9 AC1-3/BLR BX-300 10.71.3.33 BX-10 AC4-8/AD BX-300 10.71.3.34 RX-11 RACK 1C/2C RX-300 10.71.3.35 145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.AS NOTED7/3/2019 9:16:07 AMC:\Users\monom\Documents\Revit 2017\071_Ithaca_MECH_CENTRAL_2017_monomCVV2R.rvtITHACAM400AOLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 MWSC500 SOUTH MEADOW STITHACA, NY 14850#071 NA 07/03/2019 TBD REFRIGERATION CONTROLS NETWORK ARCHITECTURE AND LEGENDSSCALE:NOT TO SCALEBREFRIGERATION NETWORK ARCHITECTURE SCALE: 1/32" = 1'-0"A OVERALL SYSTEM NETWORK ARCHITECTURE Revision Schedule # Date Revision 1 07/03/19 Permit Set CON039/071-5266 REFRIGERATI ON BALL VALVE GLUE SEAM SINGLE LAYER OF INSULATION (SPLIT INSULATION SHOWN) GLUE INSULATION TO PIPING EXTENSIONS OF BALL VALVE CUT AND REMOVE SECTION OF INSULATION TO MATCH OUTSIDE CIRCUMFERENCE OF BALL VALVE STEM CUT AND REMOVE (GOUGE) INSULATION TO ALLOW INSULATION TO TIGHTLY WRAP AROUND BALL VALVE BODY NOTES: 1. INSULATION MOCK UPS SHALL BE SUBMITTED TO ENGINEER AND WEGMANS FOOD MARKET FOR APPROVAL. INSTALLATION OF INSULATION SHALL NOT PROCEED UNTIL APPROVAL OF MOCK UP HAS BEEN RECEIVED. 2. CONTRACTOR SHALL FOLLOW MANUFACTURER'S INSTALLATION GUIDELINES AS INDICATED IN SPECIFICATIONS. GLUE AND TAPE BUTT JOINT (TYPICAL) ADJACENT SECTION OF PIPE INSULATION DOUBLE OR SINGLE LAYER INSULATION AS SPECIFIED (DOUBLE LAYER SHOWN). TAPE (TYPICAL) GLUE SEAM GLUE OVERLAP GLUE OVERLAP INSTALL TAPE ON OUTSIDE CIRCUMFERENCE TO FACILITATE SLIDING OF EXTERIOR INSULATION WRAP EXTERIOR INSULATION WRAP. TAPE EXTERIOR OF INSULATION, DO NOT GLUE. EXTERIOR INSULATION SHOULD BE ABLE TO SLIDE OFF TO ACCESS BALL VALVE STEM. GLUE SEAM GLUE SEAM GLUE SEAM GLUE ALONG LENGTH OF PIPING EXTENSIONS AND ENTIRE VALVE BODY TO ENSURE TIGHT FIT BETWEEN VALVE/PIPING AND INSULATION SECOND LAYER OF INSULATION (SPLIT INSULATION SHOWN) SECOND LAYER OF INSULATION (SPLIT INSULATION SHOWN) 12" LONG 12" LONG 8" LONG 8" LONG 12" LONG INSULATION SHALL BE OF A THICKNESS WHICH WILL ENSURE THAT THE TOP OF THE BALL VALVE STEM IS FLUSH WITH TOP OF INSULATION HYDRA-ZORB KLO- SHURE PIPE SUPPORT REFRIGERANT PIPE EXPANDED VIEW. INSULATION REMOVED FOR CLARITY. "KINDORF" SLOTTED BACK 1-5/8" UNISTRUT. HYDRA-ZORB KLO-SHURE PIPE SUPPORT ELASTOMERIC INSULATION. THICKNESS PER SPECIFICATION ELASTOMERIC INSULATION. THICKNESS PER SPECIFICATION 1" MIN. TYPICAL REFRIG. SUCTION LINE DOUBLE LAYER OF 1/2" INSULATION (SINGLE LAYER OF 1" INSULATION ALSO ACCEPTABLE) (INSTALL WITH SEAM UP) ANCHOR LIQUID AND SUCTION LINE TO CHANNEL USING KLO- SHURE w/HYDRA-ZORB INSULATION COUPLING. (DX & CO2 PIPING ONLY) TYPICAL REFRIG. LIQUID LINE w/SINGLE LAYER OF 1-1/2" INSULATION (INSTALL WITH SEAM UP) NOTES: 1. 2-1/2" AND LARGER - AT ALL HANGERS, INSTALL HIGH DENSITY INSULATION INSERTS WITH PIPE SHIELDS. SEAMS SHALL BE GLUED PER MANUFACTURERS RECOMMENDATIONS. (GLYCOL PIPING ONLY) 2. 2" AND UNDER - AT ALL HANGERS INSTALL INSULATION. GLUE SEAMS PER MANUFACTURERS RECOMMENDATIONS. (GLYCOL PIPING ONLY) 3. ALL SEAMS AND JOINTS TO BE SEALED WITH INSULATION ADHESIVE. IN ADDITION BUTT JOINTS SHALL BE SEAMED WITH BLACK INSULATION TAPE. REFER TO SPECIFICATIONS FOR APPROVED MANUFACTURERS. D X S U C T IO N D X L IQ U ID ELEVATION EVAP.EVAP. PROVIDE PVC COVER ON INSULATION FROM TOP OF CASE UP TO 10' ABOVE CASE SUCTION TRAP, SEE DETAIL 'E' THIS DRAWINGPPPP REFRIGERANT OIL STREET ELBOWS (TYPICAL OF 3) SUCTION PIPE SLOPE 1/4" PER 10 FT. TOWARDS COMPRESSOR SUCTION RISER NO OFFSETS ALLOWED IN VERTICAL PIPING REDUCE HERE 145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.NONE7/2/2019 3:19:32 PMC:\Users\monom\Documents\071_Ithaca_MECH_CENTRAL_2017_monomCVV2R.rvtITHACAM308OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 MWSC500 SOUTH MEADOW STITHACA, NY 14850#071 NA 07/03/2019 TBD REFRIGERATION DETAILSSCALE:NOT TO SCALECREFRIGERATION VALVE INSULATION INSTALLATION DETAIL SCALE:NOT TO SCALEBVERTICAL REFRIGERATION PIPING SUPPORT DETAIL SCALE:NOT TO SCALEDREFRIGERATIONT PIPE TRAPEZE DETAIL SCALE:NOT TO SCALEADX TO TYP. CASE W/ OFF-TIME OR ELEC. DEFROST SCALE:NOT TO SCALEESUCTION TRAP RISER DETAIL Revision Schedule # Date Revision 1 07/03/19 Permit Set REF037/071-5266NOT USED 10-CAS039110-CAS039110-CAS039110-CAS039110-TBL060310-TBL060300-GRD000400-GRD000410-CAS031710-CAS029800-GRD000400-GRD000400-GRD000400-GRD000410-CAS029810-SCL006710-SCL006710-TBL070400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000410-TBL070410-TBL060310-TBL060310-TBL046410-TBL046410-TBL046410-TBL046410-TBL010010-TBL010010-TBL010010-WPR000210-CAB002710-CAB0027TBL0631VIF WIDTHVIF DEPTH3' - 0"3' - 0"5' - 0"8' - 0"4' - 3"EFGH109876H.15E.46.96.86.7G.5.3G.5.24.6Y.4Y.3Y.2Y.18.6Z.12B41/2"5/8"5/8"404AM308A2B51/2"5/8"5/8"404AM308A2B71/2"5/8"5/8"404AM308AP 1B232C91 1/8"2 5/8"2 5/8"1 1/8"3 1/8"3 1/8"1 3/8"3 1/8"1 3/8"1 1/8"1/2"7/8"1/2"2B61/2"5/8"5/8"404AM308A1/2"1 3/8"5/8"2 5/8"1 1/8"1 3/8"5/8"2 5/8"1 1/8"1/2"5/8"1 5/8"1 1/8"1/2"3/8"7/8"1 5/8"5/8"7/8"1/2"1 1/8"1/2"1/2"7/8"1/2"5/8"5/8"3/8"5/8"1/2"7/8"1/2"1B161B102B135/8"1 3/8"1/2"1 3/8"1C21 5/8"5/8"5/8"1 3/8"1 1/8"1/2"1/2"1 3/8"7/8"1/2"1 1/8"1/2"1/2"1 1/8"1/2"1 1/8"1B151/2"7/8"2 5/8"1 5/8"4 1/8"2 1/8"1 5/8"1/2"7/8"1/2"1/2"1 1/8"7/8"1/2"1B47/8"1 5/8"5/8"1 5/8"5/8"1 3/8"5/8"1 1/8"1/2"5/8"5/8"1 3/8"1/2"7/8"3/8"5/8"1B81B61B92B141B261B52 1/8"1 3/8"145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional SealSCALE:Store No:PRICING SET:PERMIT SET:CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.NONE7/2/2019 12:59:10 PMC:\Users\cooneys\Documents\071_Ithaca_MECH_CENTRAL_2017_CooneyS.rvtITHACAM302_2OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET07/03/19MWSC500 SOUTH MEADOW STITHACA, NY 14850#071NA07/03/2019TBDQUADRANT 2 REFRIGERATION PIPING PLANNKEY PLANN.T.S531BDF10HM302_3M302_2M302_4M302_1GENERAL NOTES:1. KEEP ALL PIPING TO THE BACKSIDE OF CASES. COORDINATE WITH ELECTRICAL BOXES. COORDINATE PIPING INSTALLATION WITH WEGMANS CONTRUCTION PRIOR TO CONSTRUCTION.2. CONTRACTOR TO PROVIDE ESCUTCHEONS FOR ALL CEILING PENETRATIONS.3. ALL PIPE DROPS SHALL BE SUPPORTED BY 1-5/8" UNI-STRUT CHANNEL WITH KLO-SHURE STRUT MOUNTED CLAMP.4. ALL SUCTION RISERS SHALL BE STRAIGHT WITH NO OFFSETS.DRAWING NOTES:1. ENCLOSE ALL REFRIGERATION PIPING DROPS IN 6" PVC, PRIME CONDUIT, SPLIT DUCT. THE DUCT TO BE FASTENED USING STAINLESS STEEL PIPE CLAMPS. COORDINATE ENCLOSURE PLUMBING, ELECTRICAL, AND CONTROLS CONTRACTORS FOR OTHER TRADES BEING ENCLOSED IN SPLIT DUCT. INSULATE ALL REFRIGERATION PIPING IN SPLIT DUCT PER INSULATION SCHEDULE.2. REFRIGERATION PIPING TO RISE UP TO CONDESNING UNIT ON ROOF. REFER TO DWG. M-107 FOR CONTINUATION OF PIPING. ALL PIPING SHALL BE SIZED AS PER MANUFACTURER'S RECOMMENDATIONS.3. PROVIDE P-TRAPS IN SUCTION RISER AT BASE, AT 15'-0" INTERVALS AND AT TOP OF RUN. PITCH HORIZONTAL RUNS IN THE DIRECTION OF REFRIGERANT FLOW, MINIMUM 1/2"/10 FT.Revision Schedule#Date Revision1 07/03/19 Permit SetREF037/071-5266 COFFEEBEANCABINET17-DPR003617-DPR003617-DPR003617-DPR003617-COFFEEROASTER17-CAB080517-CAB097817-CAB098417-CAB080517-CAB085217-CAB080617-BIN015117-REF016717-REF016717-REF016717-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-STD009317-CAB092817-DPR010717-DPR010717-DPR010717-REF016717-REF011217-OVN010717-OVN010317-DPR013017-RGS000417-DPR012817-DPR012017-REF024417-REF021917-CPA003517-GDR000817-GDR000817-SCL005817-GDR000817-COFFEEBEANCABINET17-COFFEEBEANCABINET17-CAB074717-COFFEEBEANCABINET17-MXR002917-MXR002917-MXR002917-OVN010717-DPR003617-DPR003617-DPR003617-DPR003617-DPR003617-DPR003617-DPR003617-DPR003617-DPR003617-DPR003617-REF028517-GDR002617-WRM006517-TELEPHONE17-BIN002417-GDR002717-SNK025317-SNK050817-CPA003910-CAS039110-CAS039110-CAS039110-CAS039110-TBL060310-TBL060300-GRD000400-GRD000410-CAS031710-CAS029800-GRD000400-GRD000400-GRD000400-GRD000410-CAS029803-CAS010403-CAS010407-CAS010507-CAS010507-CAS010507-CAS010507-CAS020600-GRD000600-GRD000607-STG023307-SCN000107-MNR001507-RGS000407-WKS019607-PNT001407-WKS019507-CAB037707-WKS023507-MED000107-FRZ006407-SHF0122 07-SHF012207-SHF0122 07-SHF012207-SHF012207-SHF012307-SHF012207-SHF012207-SHF012307-SHF012507-SHF012507-SHF012207-SHF012307-CAB057107-CAB057107-CAB036707-CAB036707-DPR010807-PNT001107-CAB036707-CAB036707-DPR01080 7 -M N R 0 0 1 5 07-MNR001507-PNT001007-CAB036707-CAB036707-DPR010807-CAB036707-CAB036707-DPR01080 7 -M N R 0 0 1 5 07-MNR001507-SNK015207-CAB034107-CAB010507-CAB017407-CAB010607-REF009607-CAB010607-CAB017407-CAB046007-CAB046107-CAB046107-MNR001507-CAB026607-CAB026607-CAB038407-CAB026607-CAB038407-CAB026607-MNR001507-PNT001407-MNR001507-SHF012207-SHF012307-WKS019607-WKS019607-WKS019607-CAB037807-SCN000107-MNR001507-RGS000407-CAB037807-SCN000107-MNR001507-RGS000407-CAB037807-SCN000107-MNR001507-RGS000407-MNR001507-PNT001407-WKS019507-MNR001507-CAB037707-PNT001407-CAB038407-WKS023507-MNR001507-PNT001407-MNR001507-CAB046307-CAB038407-STG023307-STG023310-SCL006710-SCL006710-TBL070407-DRG0009VIF WIDTH07-SHF020307-SHF020307-MNR001500-REF024200-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000400-GRD000410-TBL070410-TBL060310-TBL060310-TBL046410-TBL046410-TBL046410-TBL046410-TBL010010-TBL010010-TBL010010-WPR000210-CAB002710-CAB002707-SCN000107-SCN000107-SCN000107-SCN000107-CPA003507-CPA003507-CPA003507-CPA003507-CPA003507-PNT002407-PNT002407-PNT002407-PNT002407-PNT002407-RGS000407-STG023407-STG023407-STG023407-STG023407-STG023407-STG023407-STG023407-SCN001507-SCN001507-PNT001007-CPA003307-CPA003307-CPA003307-CPA003307-FAX07-TELEPHONE07-TELEPHONE07-TELEPHONE07-WKS020924-STG010924-STG010924-STG010924-STG010924-STG010924-STG010924-STG010924-TBL0722ADA24-TBL0722ADA27-DIV007927-DIV007927-DIV007927-DIV007927-DIV007927-CPA003927-CPA003927-CPA003927-CPA003927-CPA0035 27-CPA0035 27-CPA0035 27-CPA003527-RGS000427-RGS000427-RGS000427-RGS000427-SCN0008 27-SCN000827-SCN000827-SCN000827-WKS039927-WKS0398 27-WKS039827-WKS040000-GRD000400-GRD000404-CAS0104 04-CAS010486-VND000486-TBL060086-SLC000986-TBL060086-SNK004886-REF016786-WRM005686-OVN011686-TBL069386-REF020186-TBL069386-REF020186-CAB085886-TBL03208 6 -D P R 0 0 9 3 86-ICM004486-CAB002786-DSK000486-TBL006286-RKM015238-KTL001338-KTL001338-SCL006738-SCL006738-SHF0258 38-SHF0258 38-SHF0258 38-SHF025838-RKF0073 38-RKF0073 38-RKF0073 38-RKF0073 38-RKF007338-REF0124 38-REF012438-SHF025838-SHF025838-TBL035938-FDP000438-FDP002238-WPR000238-SHF022938-SHF022938-TBL048138-SNK0062CAB029938-SNK025538-TBL032038-OVN014638-RKM003238-RKM003238-RKM003238-CRT000738-CRT000438-CRT000438-CRT000438-CRT000438-RKM003238-RKM003238-CRT000738-RKM003238-RKM003238-SHF025838-SHF0258RKF0073RKF007338-SNK025338-CNV002938-TBL0631VIF WIDTHVIF DEPTHTBL0631VIF WIDTHVIF DEPTH18-CRT000418-CRT0004CAB002788-WRM002523-CAS008323-CAS033628-GRD000428-GRD000428-GRD000428-GRD000428-CAS032828-GRD00042 8 -G R D 0 0 0 4 2 8 -G R D 0 0 0 428-GRD00042 8 -C A S 0 3 2 9 23-TBL058128-DPR007428-DPR007428-TBL033028-TBL058128-TBL054390-SCL007300-PCL000190-TBL035428-OVN015428-OVN015428-OVN011328-TBL0576BOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARY3' - 0"3' - 0"5' - 0"8' - 0"4' - 3"AAA.2A.2A.3A.3A.6A.6BBB.2B.2B.3B.3B.5B.5B.7B.7CCDDEEFFGGHH101099887766H.1H.155443322110.90.9000.30.3C.7E.46.96.86.7G.5.3G.5.24.64.34.24.13.63.43.33.12.92.52.31.61.51.31.2Y.4Y.3Y.2Y.18.6X.3X.2XZ.1W.17.86.5B.9C.3C.5C.6D.1D.5D.8E.3E.6E.7F.1F.2F.3F.5F.6F.7F.8G.1G.4G.5.1G.5.4G.62B41/2"5/8"5/8"404AM308A2B51/2"5/8"5/8"404AM308A2B71/2"5/8"5/8"404AM308AP 2B252B262C62C101B241B232C91 1/8"2 5/8"2 5/8"1 1/8"7/8"2 5/8"2 5/8"2 1/8"1 5/8"7/8"5/8"1 1/8"1 5/8"1 5/8"1 1/8"5/8"1B SUCTION2B SUCTIONLIQUID3 1/8"3 1/8"1 3/8"3 1/8"1 3/8"1 1/8"1/2"7/8"1/2"2B61/2"5/8"5/8"404AM308A1/2"5/8"1 3/8"1/2"1 3/8"5/8"2 5/8"1 1/8"2 1/8"7/8"5/8"1 3/8"1 5/8"1/2"1 1/8"5/8"5/8"1 3/8"7/8"1/2"1/2"7/8"1 1/8"1/2"1/2"1 1/8"1/2"7/8"1 1/8"1/2"1 1/8"1/2"1 1/8"1/2"1 5/8"7/8"7/8"1/2"1 3/8"5/8"1 3/8"5/8"2 5/8"1 1/8"1/2"5/8"1 5/8"1 1/8"1/2"3/8"7/8"1 5/8"5/8"7/8"1/2"1 1/8"1/2"1/2"7/8"1/2"5/8"5/8"3/8"5/8"1/2"7/8"1/2"1B161B102B135/8"1 3/8"1 1/8"1/2"1/2"1 3/8"1C21 5/8"5/8"5/8"1 3/8"1 1/8"1/2"1/2"1 3/8"7/8"1/2"1 1/8"1/2"1/2"1 1/8"1/2"1 1/8"1B151 1/8"1/2"7/8"1/2"1 1/8"1/2"1/2"7/8"2 5/8"1 5/8"4 1/8"2 1/8"1 5/8"1/2"7/8"1/2"1/2"1 1/8"7/8"1/2"1B47/8"1 5/8"5/8"1 5/8"5/8"1 3/8"5/8"1 1/8"1/2"5/8"1/2"5/8"5/8"1/2"5/8"1 3/8"1/2"7/8"3/8"5/8"1B81B61B92B141B261B52 1/8"1 3/8"1 5/8"1/2"1 3/8"1 1/8"1/2"1/2"1 1/8"2B212B202B91/2"7/8"1/2"1 1/8"7/8"1/2"2C5145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road, Suite 200Rochester NY, 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional SealSCALE:Store No:PRICING SET:PERMIT SET:CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.1/16"=1'-0"7/2/2019 1:00:20PMC:\Users\cooneys\Documents\071_Ithaca_MECH_CENTRAL_2017_CooneyS.rvtITHACAM302OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET07/03/19MWSC500 SOUTH MEADOW STITHACA, NY 14850#071NA07/03/2019TBDREFRIGERATION PIPING PLANNKEY PLANN.T.S10531BDFHM302_3M302_2M302_4M302_1GENERAL NOTES:1. KEEP ALL PIPING TO THE BACKSIDE OF CASES. COORDINATE WITH ELECTRICAL BOXES. COORDINATE PIPING INSTALLATION WITH WEGMANS CONTRUCTION PRIOR TO CONSTRUCTION.2. CONTRACTOR TO PROVIDE ESCUTCHEONS FOR ALL CEILING PENETRATIONS.3. ALL PIPE DROPS SHALL BE SUPPORTED BY 1-5/8" UNI-STRUT CHANNEL WITH KLO-SHURE STRUT MOUNTED CLAMP.4. ALL SUCTION RISERS SHALL BE STRAIGHT WITH NO OFFSETS.DRAWING NOTES:1. ENCLOSE ALL REFRIGERATION PIPING DROPS IN 6" PVC, PRIME CONDUIT, SPLIT DUCT. THE DUCT TO BE FASTENED USING STAINLESS STEEL PIPE CLAMPS. COORDINATE ENCLOSURE PLUMBING, ELECTRICAL, AND CONTROLS CONTRACTORS FOR OTHER TRADES BEING ENCLOSED IN SPLIT DUCT. INSULATE ALL REFRIGERATION PIPING IN SPLIT DUCT PER INSULATION SCHEDULE.2. REFRIGERATION PIPING TO RISE UP TO CONDESNING UNIT ON ROOF. REFER TO DWG. M-107 FOR CONTINUATION OF PIPING. ALL PIPING SHALL BE SIZED AS PER MANUFACTURER'S RECOMMENDATIONS.3. PROVIDE P-TRAPS IN SUCTION RISER AT BASE, AT 15'-0" INTERVALS AND AT TOP OF RUN. PITCH HORIZONTAL RUNS IN THE DIRECTION OF REFRIGERANT FLOW, MINIMUM 1/2"/10 FT.Revision Schedule# Date Revision1 07/03/19 Permit SetREF037/071-5266 CONTROLTEMPAMPS460 V460 V 115 VA.S.HTR.AMPS115 VAMPSFIX.LIGHTAMPS115 VEVAP.FANAMPSH.R.FANAMPS208 VROOFCOND.FANPERDAYUNITRLAMISC.MINUTESRUN OFFTERM/TYPE(S) SENS.(O) 0.0.R.(C) C.O.R.(DD) DMD./DF.ANDELECTRICAL DATA(N) NONE TERMINALTEMPURATURELOCATIONDEFROST RECOMMENDATIONSSCHEDULE START / TIMESNO.INSTALLEDON MANIFOLDSREFRIG.PRESSURECONTROLSMISC.NOTESDEFROSTMEANSDURATIONINMINUTESINLSVEPRORSSVLIQ. LINESHUT-OFFVALVEVALVESHUT-OFFSUCT. LINEACCESSORIESACCESSORIESINSTALLEDON FIXTURESDEFROSTTERMCONTROLLSVEPRORSSVSETTINGLINE-UPANDREFRIG.AREASFORREFRIG.AREASEVAP.FIXTURE & REFRIGERATEDTXVCIRCUITAREA DATAMBHSUCTIONTEMP.REQ.'DFIXTUREDESTINATIONUNIT DATACONDENSINGUNITDESTINATIONDEPARTMENTCODECOMP.CLEANSWITCHALARM(MIN)ALARM DATAALARMHIGHTEMP(DEG)ALARMLOWTEMP(DEG)ALARMDELAY(MIN)ALARMPRIORITYLFA-150ME6S14012' HFES 1-1/2 RCCPCHFES 1-1/2 RCA8AS 208VOPTIMIZER22° OPT--- ---WESCHONOT REQ.'D(3) LFA-270 (3) HFES 3-1/2 RCLFA-120 HFES 1 RC AT UNIT---EMIWESCHOME6S140REMOTESPORLANME6S130ME6S130ON COILNOTE 6SBFR-BCCONTROL LINKLWA-155EMISPORLANTBC/24D0EMIEMIEMICLC/24D5ON UNITEMISBFR-BCWSP/12D3WSP/12D3TBC/24D5ME6S140ME6S130ME6S130SPORLANSBFR-BCTBC/24D0---8' HFESC 1 RC+(45)SET 88#(3) ME10S250HILLNOT REQ.'DHILL26° - 32° D.A.WESCHOWESCHOWESCHO45° B.T.1-3° D.A.ME 342:00FLOAT 2A-1, 2SUCTION LINE HEAT EXCHANGERSUCTION LINE HEAT EXCHANGERNOTE 5ON COIL(16) 1 HP17:00662:00 6:005:0010:009:00 13:00404A14:00111:004:005:0011S-DD1010 S-DDMACHINE SHUTDOWN3030TIME CLOCK AT CASEDOOR SWITCH OPEN LSV+FANSRMC DEFROST SCHEDULES5:00RX-300UNIT 3SETPIONT 13#MIN 12# - MAX 18#404A1 00:0024EVAP. COILS ON 2A-5404A1-1/8"RX-300UNIT 2DEFROST CONTACTORSS2 1101/2"404ANOTE 5FLOAT 2A-16, 17 & 18-13° BOX(I.C. SUCT.)7# - 1# (10)SETPOINT 8#-5° D.A.24BACK-UP LPCUT IN - CUT OUT9# - 3# (7.5)8# - 2# (10)DEAD BAND 2#2424BACK-UP LPCUT IN - CUT OUT2424404AHOT GAS404A404A2-5/8"SUCT73° DUMP LINE404A404A404A404A404A404A404ANOTE 5 5/8"NOTE 5NOTE 51-1/8"LIQ.LSV OR SSVREMOTENOTE 5DEAD BAND 2#NOTE 5NOTE 5NOTE 5NOTE 5-22° D.A.8# - 2# (22)FLOAT (4) 1A-1BACK-UP LPCUT IN - CUT OUT9# - 3# (7.5)7# - 1# (22)MIN 8# - MAX 13#404A404AON RACK404A404A2A-12 & 13 HAVE404A404A404A404A404A404A404AREMOTE LSVREMOTEMANIFOLDBACK-UP LPCUT IN - CUT OUT404A404A404A404A404ARANGE A/DSTAT 33° CO.A81S 208VRANGE A/DEPR 70#REMOTE LSVEPR/SSVEPR FLO-CON. A 8AS404A404A404A404ASORIT - 2072# - 64# (12)73# - 65# (5)MIN 76# - MAX 86#FLOAT 2A-19 & 2065° BOXSETPOINT 75#OFF CYCLERX-300UNIT 316.1 (7.5)33 (22)ELECTRIC16.1 (7.5)82.1 AMP4.20 13.60TOTAL RLARACK 1A460-3-60DFROST10.4016.1 (7.5)33 (22)33 (22)2.16 3.20404A404A404A404A404A10 F.P.I.(4) 1 HP14.0 FLA460-3-604.2@ 208-1-604.2@ 208-1-6018:00 22:0021:00 1:0022 (10)22 (10)(2) BRX-118A460-3-6019.2 FLA460-3-60P/H-A(20) 1 HP0.3208-1-600.3208-1-601.1208-1-600.3208-1-60208-1-6013.1208-1-60208-1-6013.1RACK 2A67.7 AMP33.6 (20)23.6 (12)TOTAL RLARACK TOTAL217.71.1208-1-601.11.0208-1-601.122.4208-1-603040459.0OFF CYCLE 30(3)HFES 3-1/2 RCOFF CYCLEELECTRIC53# - 45# (20)SUCTION LINE HEAT EXCHANGER55# - 47# (5)54# - 46# (10)RX-300MIN 52# - MAX 62#BACK-UP LPCUT IN - CUT OUTUNIT 551# - 43# (25)52# - 44# (20)FLOAT 2B-8 & 932° OPTME10S250NOT REQ.'DME10S250ME6S140LARKINHILL404AON COILS404ALARKIN404A404A404A404A404A404A404A404ACPC PROBE404AOR SSVNOT REQ.'D404A404AHFESC 1-1/2 RCHILLME6S140REMOTE LSVLWA-130(2) LWA-210LFA-120 HFES 1 RC404A404A404A404A404A404A404A404AEPR FLO-CON. A81S1-5/8" W /1-3/8" PORT 240-1-603)S-DDNN7/8" W/ 3/8" PORT 240-1-604040(3) LFAE-27032° D.A.53035--- ---460-3-60P/H-BRACK TOTAL325.6 AMP208-1-60 208-1-60208-1-60208-1-600.3 13.10.3 13.1208-1-60208-1-601.1 22.4RMCC USED FOR NIGHT OVERRIDE& ALARM OR LSV SHUTDOWNBACK-UP LPCUT IN - CUT OUTGROUP 2RMC #3SETPOINT 45#MIN 43# - MAX 50#FLOAT (3) 1B-5+21° D.A.40# - 32# (5)39# - 31# (10)38# - 30# (20)404A404A404A404A404A404A404A404A404A404A404A404A43:30 9:30 15:3014:304 21:308:30 20:302:304404AREMOTE LSVOR SSV404A208-1-602.420.0 (10)33.3 (20)33.3 (20)53.5 (35)150.6 AMP00:00 6:00 12:00 18:0015.321.56 14:003460-3-6024.0 FLA(2) BRX-154A5:00 13:00 21:002:001.418:00 22:0018:30 00:3046:00 10:006:30 12:30(3) 1.4AELECT DEF.(3) COILS @ 14.3A EACH4208-1-60208-1-60(3) 1.4A10.5 (5)10.5 (5)33.3 (20)41.1 (25)175.0 AMPTOTAL RLA460-3-60RACK 1B--:--2:00--:-- --:-- --:-----431:308:00 14:00 20:00 2.15KLIXON FROMFACTORYON RACKMLG4-330---ME6S140EMISBFR-AC---CLC/24D0SPORLANHILLHILLCONTROL LINKHILLWSP/12D3SPORLANWSP/12D3404A404A404A404A404A404A404ACLC/24D5SPORLANREMOTE LSVOR SSVREMOTEMANIFOLDEMION UNITNOT REQ.'DME6S130SBFR-BCME6S140EMISETPOINT 75#RX-300UNIT 3BACK-UP LPCUT IN - CUT OUTMIN 76# - MAX 86#65° BOX73# - 65# (7.5)EMIFLOAT 2B-32SBFR-ACME6S130-3° D.A.-3° D.A.-3° D.A.-3° D.A.-3° D.A.EPR 85#39° - 41°RANGE A/DA8AS 208V7/8" W/ 5/8" PORT 240-1-60EPR FLO-CON. A 8AS2.4208-1-60404A461 20:301.23 8.41SPORLANSBFR-CCHILL HILL NOT REQ.'D354 4:00 10:00 16:00EMIWSP/12D320.0 (10)ME6S140SORIT - PI - 2-2 +20° BOX1.29404A404A404A404A404A404A404AEMIWSP/12D3EMIWSP/12D3EMIWSP/12D3ME10S2506:00HILLME6S140ME6S140ME6S140EMITBC/24D0ME6S130ME6S14013.10.3208-1-60 208-1-60208-1-60208-1-600.3 13.113.10.3208-1-60 208-1-60208-1-60208-1-600.3 13.1--- ---------31° D.A.SPORLANSBFR-CC404A404A404A404AHILLREMOTE LSVOR SSVREMOTEMANIFOLD404A404AHILL HILL NOT REQ.'D30° D.A.WESCHOREMOTE LSVOR SSV2:30 20:308:30 14:302.0A208-1-604510:00 16:004:00 22:004208-1-602.4AIR FLUE52° RETURN9.34 20:3014:308:302:3024.287)C60AIR DEFROST9.529 AMP29.0 (15)1B SAT.N45322:00--- ---42---4--:----:----:--13:0007:001:00208-1-600.313.1208-1-601.1208-1-6013.1208-1-60208-1-600.3404A404AME6S130ME6S130ME6S130LWA-100 HFES 1 RCME6S130RX-300UNIT 4MIN 42# - MAX 48#BACK-UP LPCUT IN - CUT OUT37# - 29# (10)36# - 28# (25)37# - 29# (25)359030208-1-6023.3A208-1-603.6EACH19:0011:003:00314:302:30241.1 (25)---3.882.63.38.8--- ------10 F.P.I.EACH208-1-602.221:309:30 15:303:30437.986.586.51AMBH2A43.2MBH98.0206.061.0MBH2AHIGH SIDECOMMONSUCTIONSPLITMBH33.147.263.2SPLITSUCTIONCOMMONHIGH SIDESPLITSUCTIONCOMMONSAT.1BMBH75.5MBH84.541.9156.0121.1156.02BMBH209.047.2136.0136.0264.02BSPLITSUCTIONCOMMONHIGH SIDESUBCOOLING@ 55° LIQUIDCAPACITYLOW-TEMP. DEMANDCOOLING COMPRESSORS210.9 MBH4DT3F76KE*4DT3-220E3DBDF33KL*334.5 MBH-20°/105° C.T.SET 24#-25° RACKSORIT TOSUBCOOLING@ 55° LIQUID299.0-15°/105° C.T.4DT3-220E3DB3-075E239.2 MBH2A 1-14, 48CAPACITY@ 55° LIQUIDCAPACITYSORIT-202A 15-20, 49, 50143.5 MBHSUBCOOLING4DA3-101E3DB3-075E179.38 MBH-25°/105° C.T.4DL3-150E75.5 MBH+10°/110° C.T.3DB3-100ECOMPRESSORSSATELLITE1B 3-304DK3R22ME4DA3-200E2DD3-050E3DB3-100ECOMPRESSORSSATELLITE4DH3-250E2A 21-47442.0 MBH4DA3-200E2DC3-050E+40°/105° C.T.1B 1-2TO +20° RACKCHECK VALVE+15°/110° C.T.559.4 MBH2B 1-284DA3-200E6DH3-350E4DA3-200E4DR3-300E+20°/110° C.T.792.2 MBH2DD3-050E471079653623541E34363035A35B33323129282725242326222120EE131916181715E1211232221201916171814121315112987645310E112138321311109427a27262524122225382324261716151420191821434544424140396' x 22' BAKERY FREEZER (FRONT)HVAC & TOGGLESECURITY OFFICE (ACR-4)CASHIER OFFICE (ACR-5)HVAC & TOGGLEFRONT OFFICE (ACR-3)HVAC & TOGGLEHVAC & TOGGLEFREEZER VESTIBULETELEPHONE ROOM (ACR-1)HVAC & TOGGLECOMPUTER ROOM (ACR-2)SPARESPARE1/2 WALK-IN FREEZER1/2 WALK-IN FREEZERFISH FREEZER8 DOOR ONRZ NATURES MARKETPLACE32'-0" O3.5UM PREPARED FOODS CASES16'-0" O3.5UM SEAFOOD CASES12'-0" WESCHO BAKERY CASECHECK TO RACK +10 & +15SORIT TO RACK +15 & +1068'-0" OHMH MEAT24'-0" O3.5UM BAKERY CASES4'-0" WIEN CHEESE CASEHVAC & TOGGLEHVAC & TOGGLEATM-2 (ACR-10)4'-0" CF-S-R SALAD CASE8'-0" 02UM MEAT CASEMEAT/SEAFOOD PREP COOLERSPARE12'-0" WAKFDP SERVICE MEAT44'-0" WAKFDP DELI CASES 14'-0" DB DELI BACK BAR CASESSUBCOOLER LOW TEMP.SORIT TO -15 RACKPHARMACY (ACR-12)HVAC & TOGGLEHVAC & TOGGLESERVICE DESK (ACR-8)SUBCOOLER LOW TEMP.24'-0" OHMH MEAT CASESSPARERACKS 1ARACKS 2APHOTO (ACR-11)SPARESPAREMEAT/SEAFOOD PREP COOLERBAKERY COOLERSERVICE MEAT COOLERFISH COOLERPRODUCE COOLER36'-0" ON5DM PRODUCE CASESBAKERY RETARDERSUB COOLERCOOLERDELI/CHEESE COOLER24'-0" WAFKDP FISH CASESSPAREEMP. SCHED. OFFICE (ACR-15)HVAC & TOGGLEHVAC & TOGGLECONFERENCE ROOM (ACR-19)SPAREHVAC & TOGGLERECEIVER'S OFFICE (ACR-14)HVAC & TOGGLEHVAC & TOGGLEHVAC & TOGGLESIGN SHOP (ACR-13)HVAC & TOGGLEMANAGER'S OFFICE (ACR-18)ASST. MANAGER'S (ACR-16)PERSONNEL OFFICE (ACR-17)COOLER (BAKERY AREA)12'-0" PTVS SUSHI CASEPREP. FDS. COOLER1 DOOR HOBART PIZZA REFRIG14.910.48.711.78.78.718.012.06.06.015.518.09.38.433.033.019.422.08.016.16.0102.06.018.018.012.098.932.56.018.010.46.06.06.042.06.06.012.210.510.513.074.211.953.039.60.063.2-7°-15°-7°-7°-7°-7°-7°-7°+40°+40°+40°---+40°+40°+40°----15°-25°-25°-25°-15°+40°+40°+40°+40°+40°+40°+40°+20°+20°+15°+17°+22°+15°---+22°---+10°---+15°+22°---+15°+22°---+15°+15°+26°+22°+15°+20°+22°+22°+20°+20°+20°+20°+20°---+20°+20°---+20°+20°+20°+20°+20°+22°+20°+20°+20°+20°+22°+20°+40°+40°+40°+40°+40°+40°+40°+40°+40°+40°1-5/8"28112.813.4ON RACKMIN 20# - MAX 25#NOTE 5NOTE 5NOTE 4404A404A404AUNIT 3SETPOINT 20#RX-3002473° DUMP LINE24HOT GAS10:0011:0014SPARE-15°12.0BAKERY FREEZERRW 45HFES 1-1/2MLT4-165CPC ON COIL ME6S1400° BOX-2 +2PIZZA FREEZERNOTE 5404A-15°8.1 -15°SETTINGCPCMLT4-100 HFES 1 RC0° BOX-2 +2ME6S130CPC ON COIL98.04DT3-220E12# - 6# (27)---40.4 (27)1.8208-1-60 208-1-6011.9ATOL 60.5 AMPTOL 89.5 AMPELECTRICELECTRIC6 4:00 8:00 12:00 16:00 22:00 00:0070° TUBEON COIL SHEET30 10 S-DD 6 3:00 7:00 11:00 15:00 19:00 23:003711.6 LFA-87 HFES 1 RCME6S140304 21:303:30 15:309:302.4208-1-60+29°+20°RAW PRODUCT COOLER2827404A404A30 10 S-DDCPCSETTINGEE3DF3A12OEBNE-D04-A03110 F.P.I.10.5 (5)299.8 AMP71# - 63# (20)8 F.P.I.175.011.7HILL36'-0" 0N5DM PRODUCE CASES HILL20'-0" O5DM BEVERAGE CASESHILLHILL2413:00MISTER1.7 AMP 115V9:3016'-0" WESCHO BAKERY CASES16'-0" DLP CHEF'S CASE 7.6 HILL HILL NOT REQ.'D404A0.0MLG4-330NOTE 68' PTDSF SEAFOOD CASEME10S250ME6S140ME6S140404A404A404A404A404A404A6.30 2.79---4.9 2.336.3 2.793:004 9:00 15:00 21:003:004 9:00 15:00 21:0045------------ --:-- --:--21.02:304 8:30 14:30 20:30TOTAL RLARACK 2BHILLME6S140352:00310:00WESCHO WESCHO WESCHOME6S13027° - 33° D.A.---28° D.A.---27° D.A.26° - 32° D.A.32° D.A.33° - 35° D.A.28° D.A.4212.8 LFA-150 HFES 1-1/2 RCME6S140LWA-210LARKIN36° BOX TEMP35° - 37° D.A.31° - 33° D.A.34° - 36° BOX31° - 33° BOX36° BOX TEMP301:304 7:30 13:30 19:30208-1-602.4A208-1-602.0AEMIWSP/12D0CPCSETTING404A6 DOOR ONRZ FROZEN FOOD CASE 7.9 HILL HILLME6S130461513-15 19.343.0HILL NOT REQ.'DHILL29.85.311.4ME6S140HILL HILLWESCHO WESCHO WESCHO28° - 30° D.A.NOTE 1ME6S14028° - 34° D.A.ME10S250MISTER1.7 AMP 115V453 2:30 10:30 18.30603520:3012:304:3030.690.75.96.5035° - 37°EPR 85#208-1-601:0034.4HILLHILLSORIT - PI - 2ME19S270NOT REQ.'D ME10S250 29° D.A.45OFF CYCLEOFF CYCLEOFF CYCLE47° RETURNAIR FLUE40:006:0018:0017:3012:006.01.413.521.44N63.2SPARE2.2 .82.016:008:00300:003528° - 34° D.A.ME10S250ME6S140WESCHOWESCHOWESCHO2.48'-0 05DM BEVERAGE (FROZEN FOOD EREA)39.8 HILL HILL NOT REQ.'D ME10S250 30° D.A.OFF CYCLE 453:30311:3019:301.00.9216'-0" ON5DM BEVERAGE CASESSPARE DISTRICT PHARMACY OFFICE (ACR-20)HVAC & TOGGLE12.0TBC/24D5EMIME6S14022.41.1208-1-60 208-1-60PIZZA COOLER4530E10.1HILL2416:002.16 3.20 10.40-3° D.A.OFF CYCLEOFF CYCLEOFF CYCLE30° D.A.FRONT END MANAGER (ACR-21)HVAC & TOGGLE6.0WSP/12D0EMI SPORLANSBFR-ACME6S130208-1-600.3MLT4-100RW 45HFESC 1ME6S1300° BOX-2 +230 10 S 2 1:30 17:30208-1-601.8208-1-6011.9 DEF HRT10.5 LWA-100 HFESC 1 RCME6S140 35° - 37° BOX304 6:00 12:0000:00 18:002.2208-1-601.22 2:00 20:004035° - 37° D.A.ME6S130HOBART HOBART2.031.4 HILL HILLME10S250 33° - 35° D.A.424 3:00 9:00 15:00 21:00 10.3 4.30.0 --- ------ -----------:-------:----:-- --:-- --- ---16.8 BOHN LET - 160 BOHN CPC ON COIL ME6S14030 10 SON COIL SHEET55° TUBE4 02:00 08:00 14:00 20:00 11.5 4.452'-0" ON3.5UM DAIRY CASEHILL1.66ME6S140 32° D.A.424 5:00 11:00 17:004.20 1.86 ---28'-0" ON5DM PRODUCE CASES24'-0" ON5DM PRODUCE CASES 42.1 HILL HILL49.119:00NOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'D32° D.A.32° D.A.23:00------SETPOINT 56#MMT6-300 HFESC 3-1/2 RCME10S250304 18:3012:306:3000:308.0BEVERAGE COOLER 40.0+20°36° - 38° D.A.4545ME19S270ME19S270(3) LFA-270(3) LFA-270 (3)HFESC 3-1/2 RC(3)HFESC 3-1/2 RC4:30 10:30 16:3013:004422:301:00 7:00 19:00208-1-60208-1-60(3) 1.4A(3) 1.4ADAIRY COOLER - RDRDAIRY COOLER - DOORS 77.499.936° - 38° D.A.36° - 38° D.A.4212' HFES 1-1/2 RCME6S140HILL8' HFES 1 RC7:30 13:30 19:3041:305.6 3.1816'-0" O5D DAIRY 23.933° - 35° D.A.45(2)ME19S250HILL HILL4 3:00 9:00 15:00 21:00 18.43.04 ---52'-0" O5DR DAIRY CASES 72.832° D.A.ON RACK5/8"5/8"HOT GASHOT GAS73.321.9%% LOADEDTOTAL185.962.2% LOADEDTOTAL97.754.5% LOADEDTOTAL332.975.3% LOADEDTOTAL102.0135.1%% LOADEDTOTAL412.973.8% LOADEDTOTAL684.786.4% LOADEDTOTALBARKERBARKER0.042404A4 4:00 16:00ME6S1408'-0" 05DM BEVERAGE (FROZEN & ETHNIC FOOD AREA)+20°33° - 36° D.A.14.4 HFESC 1-1/2 RCHILL10:00 22:00 1.8 .9CONTROL LINKCONTROL LINKCPC PROBECONTROL LINKCONTROL LINKCONTROL LINKCPC PROBECONTROL LINKCONTROL LINKCPC PROBECPC PROBE---CONTROL LINKCPC PROBE---CONTROL LINKNOT REQ.'DOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLEOR SSVREMOTE LSVOR SSVREMOTE LSVOR SSVREMOTE LSVREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLD1.80REMOTE LSVOR SSV2.403.00.50.94CONTROL LINKON COILHILL-3° D.A.LSV OR SSVREMOTEELECTRIC 60° ON COIL3.416.28404A16'-0" OHMH MEAT CASE +22°23.0 HILL HILLME6S140NOT REQ.'D 29° D.A.OFF CYCLE454 1:30 7:30 13:30 0.94 4.0CONTROL LINKREMOTE LSVOR SSV47° RETURNAIR FLUE19:30OFF CYCLE18:00---------------------60SPARE11a0.0 ---404A--- ------------ ---BARKERBARKER0.8142 --- 90 20CPC PROBECPC PROBECONTROL LINKCONTROL LINKCONTROL LINKAT UNITCPC PROBECPC PROBECPC PROBECPC PROBECONTROL LINKCPC PROBECPC PROBECONTROL LINKCPC PROBECPC PROBECPC PROBECONTROL LINKCPC PROBECPC PROBECPC PROBECPC PROBENOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DREMOTE LSVEPR/SSVREMOTE LSVEPR/SSVREMOTE LSVEPR/SSVREMOTE LSVEPR/SSVREMOTE LSVEPR/SSVREMOTE LSVEPR/SSVREMOTE LSVEPR/SSVREMOTE LSVEPR/SSVREMOTE LSVEPR/SSVREMOTE LSVEPR/SSVREMOTE LSVEPR/SSVMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDREMOTEOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLENNNNNNNNNN7.5LWA-075LARKIN NOT REQ.'DCONTROL LINK ME6S140 43° BOX TEMPOR SSVREMOTE LSV REMOTEMANIFOLDOFF CYCLE3016:008:0000:003208-1-600.5A49 --- 90 2042 --- 90 2042 --- 90 20NOT REQ.'DCONTROL LINK ME6S140 43° BOX TEMPOR SSVREMOTE LSV REMOTEMANIFOLDOR SSVREMOTE LSV REMOTEMANIFOLDOFF CYCLE3016:008:0000:0031.0A49 --- 90 2048 HURRICHILL BLAST CHILLER35.0+5°HURRICHILL HURRICHILLNOTE 2NOTE 3NOT REQ.'DCONTROL LINK(FOR DUMP DOWN ONLY)404AOFF CYCLE(INTERNAL)LSV OR SSVREMOTEELECTRICELECTRICELECTRICHOWE ICE MACHINE9.5+3°HOWE HOWENOTE 2NOTE 1NOT REQ.'DCONTROL LINK(FOR DUMP DOWN ONLY)OFF CYCLE(INTERNAL)LSV OR SSVREMOTELSV OR SSVREMOTELSV OR SSVREMOTE5+22°BERRY CASEHILLHILL19.966a+20°CUT FRUIT CASEBARKERBARKER11.4+20°REAR STORAGE------2.4NOT REQ.'DCONTROL LINK ME6S140NOT REQ.'DCONTROL LINK NOTE 1---CONTROL LINK ---28° D.A.36° BOX TEMP --- --- ---404A404A404A---REMOTEMANIFOLDOFF CYCLEOFF CYCLEOFF CYCLE4530303 19:3011:303:30 --:--6 14:306:302:30 22:30618:3010:3014:306:302:30 22:3018:3010:301.08 1.242 --- 90 20--- --- --- ---30° D.A.REMOTEMANIFOLDNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DOR SSVREMOTE LSVOR SSVREMOTE LSVOR SSVREMOTE LSVOR SSVREMOTE LSVOR SSVREMOTE LSVOR SSVREMOTE LSVOR SSVREMOTE LSVOR SSVREMOTE LSVOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLEOFF CYCLENNNNN42 --- 90 201CMBH70.534.63DADR10ML2DC3R53KL+15°/110° C.T.105.1 MBH99.4 MBH91.7% LOADEDTOTALCPC PROBE ME10S250HILLHILLAIR DEFROST 42 3)COR SSV404AMANIFOLD12.766:00 12:00 18:00 00:0043.952° RETURNAIR FLUEHFESC 1 RC1 36'0" O5DM COLD CUTS 57.4 +15°29° - 31° D.A.---HILL HILL NOT REQ.'DME6S140404AOFF CYCLE 424 14:008:002:003.6 1.86---2 24'-0" OHM CHEESE 31.8 +22°28° D.A.47° D.A.CONTROL LINKREMOTE LSVOR SSVREMOTEMANIFOLD0.0-----:----- ------WESCHOWESCHOWESCHOME6S130404A3516:008:0000:003.96.283 12'-0" WAKFDP CHEESE CASE 7.2 +15°27° - 33° D.A.SORIT - PI - 2OFF CYCLE2.64CPC PROBEOR SSVREMOTE LSV REMOTEMANIFOLD--- ---------404A--- ------ --:----:----:----- ------4 SPARE 0.0 --------------:--ME6S1401:30 9:30 17:30 --:--2CMBH116.094.03DF4S11ML3DBDR12ML+20°/110° C.T.475.0 MBH400.8 MBH84.4% LOADEDTOTAL129.0 3DS4S12ML--- --- NOT REQ.'DNOTE 1404AOFF CYCLE 604 --:----:----:----- ------27b RRS COIL 1.6 +24°28° D.A.CONTROL LINK-----:----- --- NOT REQ.'DNOTE 1404AOFF CYCLE 604 --:----:----:----- ------27c DOME COIL 1.2 +24°---CONTROL LINK-----:--HILL NOTE 6 NOT REQ.'DME6S140404AOFF CYCLE 453 17:159:151:150.20 0.23---4 8' O2UM CHEESE 7.9 +22°27° D.A.CPC PROBE--:--404A---5--:--404A---6--:--404A---7--:--7+28°12 DOOR ONRB NATURESHILLHILL8.1NOT REQ.'DCONTROL LINK ME6S140 34° D.A.404AOFF CYCLE304 0:30 18:3042 --- 90 2089MANIFOLDREMOTEOR SSVREMOTE LSV12:306:301.92 1.835.914950HILL CONTROL LINK-10° D.A.60° ON COIL5---602024.434612:301.22 8.361.28HILLME6S140404A8 DOOR ONRZ NATURES MARKETPLACE 8.5 -15°15ON COILLSV OR SSVREMOTEELECTRICHILL CONTROL LINK-10° D.A.60° ON COIL5---602022.564613:303.03 16.742.48HILLME6S140404A12 DOOR ONRZ FROZEN FOODS 14.8 -15°15ON COILLSV OR SSVREMOTEELECTRICHILL CONTROL LINK-10° D.A.60° ON COIL5---602033.8410HILL HILL NOT REQ.'DME6S130404AOFF CYCLE 3040.32 0.310.9911 2 DOOR ONRZ 1.2 +28°34° D.A.CPC PROBE--- ---------404A--- ------ --:----:----:----- ------12 SPARE 0.0 --------------:----- --- --- ---(2)LWA-210 LARKIN NOT REQ.'DME10S250404AOFF CYCLE 26------STAGING COOLER (BACK DOCK AREA) 34.0 +20°35° BOX TEMPCONTROL LINK--:--HILL HILL NOT REQ.'DME6S140/CDS404AOFF CYCLE 450.50 0.540.6312' DLPT SERVICE CHEESE CASE 5.4 +22°27° D.A.CONTROL LINK--:--42 --- 90 20404A20' OUM PRODUCE CASE 15.3 +22°(8) 1 HP460-3-6028.0 FLA(1) BNE-D08-A06210 F.P.I.136.0 4DE3R18ML46'-0" ON3.5UM DAIRY CASE 46.0+20°HILL HILL404A29ME10S250 28° D.A.451.669.015.3221:0013:005:003CPC PROBECPC PROBEEPR/SSV MANIFOLDOFF CYCLE NREMOTE LSVREMOTEREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDHILLHILLME6S14030.0NOT REQ.'D 36° D.A.CONTROL LINKEPR/SSV MANIFOLDREMOTE LSVREMOTE1:004 7:00 13:00 19:0042OFF CYCLE5.85 3.542 --- 90 2030'-0" ON3.5UM DAIRY CASE 30.0+22°HILL HILL404A30ME10S250 28° D.A.450.965.08.8521:0013:005:003(1)CPC PROBE(1)CPC PROBEEPR/SSV MANIFOLDOFF CYCLE NREMOTE LSVREMOTE(2)CONTROL LINK(2)NOT REQ.'D42 --- 90 20REMOTEMANIFOLDOFF CYCLE---NREAR STORAGE22a11.42.4+20°BARKER BARKERBARKER BARKERCONTROL LINKCONTROL LINKNOT REQ.'DNOT REQ.'DNOTE 1NOTE 128° D.A.28° D.A.MANIFOLDREMOTEMANIFOLDREMOTE------20OFF CYCLE20OFF CYCLE6 14:306:302:30 22:3018:3010:306 14:306:302:30 22:3018:3010:303.24 4.842 --- 90 2042 --- 90 20MANIFOLDREMOTEOR SSVREMOTE LSV3 4:00 12:00 20:0042 --- 90 20---------40.60---0.2704:45 10:45 16:45 22:45--------------:-- --:-- --:-- --:--20:00HILLHILLHILLHILLHILLHILLON RACKON RACKON RACKON RACKON RACKON RACK7/8"1/2"7/8"1/2"1-1/8"1/2"1-1/8"1/2"7/8"1/2"1-1/8"1/2"HOT GASHOT GASHOT GASHOT GASHOT GASHOT GAS73° DUMP LINE73° DUMP LINE73° DUMP LINE73° DUMP LINE73° DUMP LINE73° DUMP LINE2.71 45.935.010.402.16 3.20 35.04.20 13.602.71 45.93.90 12.602.40 42.910.402.16 3.20 35.035.0CONTROL LINKCONTROL LINKCONTROL LINKCONTROL LINKCONTROL LINKCONTROL LINKOR SSVREMOTE LSV45° D.A.1.60 0.460.50 42 --- 90 2045° D.A.45° D.A.42 --- 90 2042 --- 90 20REMOTEMANIFOLDOR SSVREMOTE LSV REMOTEMANIFOLD45° D.A.REMOTE LSVOR SSVREMOTEMANIFOLDREMOTE LSVOR SSVREMOTEMANIFOLDREMOTE LSVOR SSVREMOTEMANIFOLDREMOTE LSVOR SSVREMOTEMANIFOLDREMOTE LSVOR SSVREMOTEMANIFOLD8.5 +15° WESCHO WESCHO CPC PROBE WESCHOREMOTE LSVOR SSVREMOTE LSVOR SSVREMOTEMANIFOLDREMOTEMANIFOLDREMOTEMANIFOLDOFF CYCLEOFF CYCLE47° D.A.42 --- 90 20HILL HILL NOT REQ.'D424 13:0007:001:0036'-0" ON5DM PRODUCE CASES63.2+22°ME10S2506.30 2.79---32° D.A.19:00CONTROL LINK47° D.A.42 --- 90 20OFF CYCLE47° D.A.42 --- 90 20REMOTE LSVREMOTE LSVOR SSVREMOTE LSVOR SSV47° D.A.47° D.A.42 --- 90 2042 --- 90 20* SEE INSTALLATIONNOTES 2 & 3HILLHILLHILLHILLHILLHILLON COILON COILON COILON COILON COILON COILCDS-45---60205---60205---60205---60205---60205---60205---60203 DOOR ONRZ / 10 DOOR ONRIZ FROZEN FOOD10 DOOR ONRIZ FROZEN FOOD10 DOOR ONRIZ FROZEN FOOD3 DOOR ONRZ / 10 DOOR ONRIZ FROZEN FOOD12 DOOR ONRIZ FROZEN FOOD10 DOOR ONRIZ FROZEN FOOD10 DOOR ONRZ FROZEN FOOD-3° D.A.-3° D.A.-3° D.A.-3° D.A.-3° D.A.ON RACKON RACKON RACKON RACKON COILON COILON COILON COILON COILCONTROL LINKCONTROL LINKCONTROL LINKCONTROL LINKCONTROL LINKHILLHILLHILLHILLHILLHILL HILLHILL-7°-7°-7°-7°-7°12.810.112 DOOR ONRZ FROZEN FOOD3 DOOR ONRZ / 12 DOOR ONRIZ FROZEN FOOD12 DOOR ONRZ FROZEN FOOD14 DOOR ONRZ FROZEN FOOD10 DOOR ONRZ FROZEN FOODHOT GASHOT GASHOT GAS2473° DUMP LINE73° DUMP LINE73° DUMP LINE2417:00HOT GAS 73° DUMP LINE12:003:002.44 3.80 12.50 42.55---60202.95 4.20 15.80 53.85---60202.44 3.80 12.50 42.55---60205---60202.98 4.40 14.50 48.15---60205---60202.16 3.20 10.40 35.05---6020ON UNITON UNITON UNITON UNITON UNITON UNITNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'DNOT REQ.'D---SPAREMANIFOLDREMOTEOR SSVREMOTE LSV45° D.A.3 0:00 8:00 16:00--- 0.9------ --- --- ---64:000:00 20:00OFF CYCLE 90HILL HILL NOT REQ.'DME6S13028° D.A.CONTROL LINK---ME6S140HILLNOT REQ.'DHILL4530.230.258'-0" 04UM PREPARED CASE 11.2 +22°30° D.A.OFF CYCLE0.80CONTROL LINK ME6S1403:30 11:30 19:30 --:--OR SSVREMOTE LSV REMOTEMANIFOLD45° D.A.42 --- 90 20------------------ME6S13045° D.A.45° D.A.28--- --- NOT REQ.'DNOTE 1SELF SERVICE COIL 6.8 +24°28° D.A.CONTROL LINK------ ---------SPARE 0.0 ------------OFF CYCLE 754 --:----:----:----- --------:----- ------ --:----:----:----- --------:----------------------------- ------ --:----:----:--0.8 2.5-----:-----42° D.A.42° D.A.40° D.A.---MANIFOLDREMOTEOR SSVREMOTE LSV46° D.A.8:00 12:00 16:001-1/8"1/2"124NOTE 5-3° D.A.-7° HILLON RACK1-1/8"1/2"HOT GAS73° DUMP LINECONTROL LINKHILL ON COIL124NOTE 514.9 HILL-3° D.A.ON RACKON COILCONTROL LINKHILL-7°14 DOOR ONRZ FROZEN FOODHOT GAS73° DUMP LINE2.98 4.40 14.50 48.17/8"1/2"1-1/8"1/2"7/8"1/2"1-1/8"1/2"1-1/8"1/2"11.73 DOOR ONRZ / 10 DOOR ONRIZ FROZEN FOOD4.20 13.602.71 45.9REMOTE LSVREMOTEMANIFOLDREMOTE LSVREMOTEMANIFOLDREMOTE LSVREMOTEMANIFOLDREMOTE LSVREMOTEMANIFOLDREMOTE LSVREMOTEMANIFOLDREMOTE LSVREMOTEMANIFOLDREMOTE LSVREMOTEMANIFOLD---REMOTEMANIFOLDREMOTE LSVREMOTEMANIFOLDREMOTE LSVREMOTEMANIFOLDREMOTE LSVREMOTEMANIFOLDREMOTE LSVREMOTEMANIFOLDREMOTE LSVREMOTEMANIFOLDREMOTE LSVREMOTEMANIFOLDREMOTE LSVREMOTEMANIFOLDREMOTEMANIFOLDREMOTE LSVOR SSVREMOTEMANIFOLDREMOTE LSVOR SSVREMOTEMANIFOLDREMOTE LSVOR SSVREMOTEMANIFOLDREMOTE LSVOR SSVREMOTEMANIFOLDREMOTE LSVOR SSVREMOTEMANIFOLDREMOTE LSVOR SSVREMOTEMANIFOLDREMOTE LSVOR SSVREMOTEMANIFOLDON UNITON UNITON UNITON UNITON UNITON UNITON UNITON UNITSPORLANNOT REQ.'DSBFR-ACSPORLANNOT REQ.'DSBFR-ACSPORLANNOT REQ.'DSBFR-ACSPORLANNOT REQ.'DSBFR-ACSPORLANNOT REQ.'DSBFR-ACSPORLANSBFR-BCNOT REQ.'DNOT REQ.'DREMOTEMANIFOLDNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOT---NOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTNOT REQUIRED NREQ'DNOTCPC ON COILSETTINGCPC2-5/8"SUCT1-1/8"LIQ.2-5/8"SUCT1-1/8"LIQ.2-5/8"SUCT1-1/8"LIQ.2-5/8"SUCT1-1/8"LIQ.1-5/8"1-5/8"SUCTION LINE HEAT EXCHANGERSUCTION LINE HEAT EXCHANGER70° TUBEON COIL SHEET70° TUBEON COIL SHEET70° TUBEON COIL SHEET70° TUBEON COIL SHEETREMOTESPORLANSBFR-BCSBFR-ACSPORLAN2.0A208-1-60--- ------------ ------ --:----:----:----- ------SPARE 0.0 --------------:----- --- --- ------ ---------SPARE 0.0 --------------- ------ --:----:----:----- --------:----- --- --- ---1/2" 7/8"42 --- 90 20--- 42 --- 90 20MANIFOLDREMOTEOR SSVREMOTE LSV47° D.A.0:30 18:3012:306:3042 --- 90 20--- ---------SPARE 0.0 --------------- ------ --:----:----:----- --------:----- --- --- ---ME6S13028° - 34° D.A.SORIT - PI - 2REMOTE LSVOR SSVREMOTEMANIFOLD35OFF CYCLE19:3011:303:3032.64.402.64REMOTEMANIFOLD47° D.A.42 --- 90 201.33.712.05.28-----------------:-- --:----- ------51 20 60 2010 --- 60 2010 --- 60 20--- --- --- ------ --:----:----:-- --:--ON COILCONTROL LINKON COILCONTROL LINK------------EPR FLO-CON A8A 7/8"W/ 5/8" PORTNOTE 6-10° B.T.-10° B.T.------CONTROL LINKSPARE ------ --------- --------- ------------ --- --- ---OR SSVREMOTE LSVREMOTEMANIFOLD45° D.A.42 --- 90 20HILL NOTE 6 NOT REQ.'DME6S140OFF CYCLE 453 17:159:151:150.20 0.23---8' O2UM CHEESE 7.9 +22°27° D.A.CPC PROBE--:--OR SSVREMOTE LSVREMOTEMANIFOLD45° D.A.42 --- 90 20HILL NOTE 6 NOT REQ.'DME6S140OFF CYCLE 453 17:159:151:150.20 0.23---8' O2UM CHEESE 7.9 +22°27° D.A.CPC PROBE--:--OR SSVREMOTE LSVREMOTEMANIFOLD45° D.A.42 --- 90 20HILL NOTE 6 NOT REQ.'DME6S140OFF CYCLE 453 17:159:151:150.20 0.23---8' O2UM CHEESE 7.9 +22°27° D.A.CPC PROBE--:--OR SSVREMOTE LSVREMOTEMANIFOLD45° D.A.42 --- 90 20145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional SealSCALE:Store No:PRICING SET:PERMIT SET:CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.NONE7/1/2019 11:47:38 AMC:\Users\cooneys\Documents\071_Ithaca_MECH_CENTRAL_2017_CooneyS.rvtITHACAM301OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET07/03/19MWSC500 SOUTH MEADOW STITHACA, NY 14850#071NA07/03/2019TBDREFRIGERATION SCHEDULE071-4106 MULTI DEPARTMENT REMODEL 2016INSTALLATION NOTES:1. CONTRACTOR TO FIELD SET NEW FLOAT SET POINTS AND RECORD SETTINGS.2. REPLACE COMPRESSOR MODEL #3DB3F33KE ON 1A RACK WTH COPELAND CORESENSE DIAGNOSTIC COMPRESSOR MODEL #3DBF33KL-TFD-A00 (DISCUS DIGITAL).A) PURCHASE AND INSTALL NEW CRANK CASE HEATER, EMERSON PART #918-0028-01.B) PURCHASE AND INSTALL NEW OIL FLOAT, AC&R PART #S-9130.C) PURCHASED AND INSTALL NEW 3D DIGITAL FAN BRACKET, EMERSON PART #074-0805-00.D) CONTRACTOR TO PURCHASE NEW CONTACTORS.E) CONTRACTOR TO PURCHASE 24 V TRANSFORMER, EMERSON PART #037-0023-00.F) CONTRACTOR TO COORDINATE WITH WEGMANS ABOUT REPLACING IN-LINE FILTERS.3. CONVERT COMPRESSPR MODEL #4DT3F76KE ON 1A RACK TO A BLOACK SUCTION UNLOADER WITH EMERSON KIT #998-2119-37.4. INCREASE RACK 1A SUCTION TEMPERATURE TO -20 DEG F.NOTES:1. SOLENOID VALVE PROVIDED BY MANUFACTURER.2. EPR VALVE PROVIDED BY MANUFACTURER. (SHIPPED LOOSE).3. INTERNAL SOLENOID VALVE PROVIDED BY MANUFACTURER. CONTRACTOR TO PROVIDE SPORLAN SOLENOID VALVE MODEL #ME6S140. SEE DETAIL F ON DRAWING M-308.4. PROVIDE SPORLAN KIT #901654 TO CONVERT SORIT-15 TO CDS VALVE.5. PROVIDE SPORLAN KIT #901655 TO CONVERT SORIT-20 TO CDS VALVE.6. TXV PROVIDED BY MANUFACTURER.Revision Schedule#Date Revision1 07/03/19 Permit SetREF037/071-5266 GENERAL NOTESDEFINITIONSABBREVIATIONSSYMBOLS - VALVES & SPECIALTIESSINGLE LINE SHOWN TO INDICATE 2 PIPES AND THE SIZE OF THE SUCTION RISER REQUIRED TO RETURN OIL TO THE COMPRESSOR UP LONG VERTICALS.1ST NO. - LIQUID SUPPLY2ND NO. - SUCTION RETURN3RD NO. - SUCTION RISERSINGLE LINE SHOWN TO INDICATE 2 PIPES, SUPPLY AND RETURN1/2", 1 1/8", 7/8"R1A1B1 1/21 1/21 1/410 GPM171/21 1/8 7/812MASTER LEGENDPOWERHOUSE-(A&B) LOCATION OF COMPRESSORS & HEAT EXCHANGERS, IN ROOFTOP PREFAB MODULE.1. THIS LEGEND SHEET IS FOR THE CONTRACTOR'S REFERENCE ONLY. NOT ALL SYMBOLS AND/OR ABBREVIATIONS MAY APPLY TO THIS PARTICULAR PROJECT. ANY ADDITIONS OR OMISSIONS FROM THIS LEGEND SHEET DOES NOT IMPLY INCLUSION AND/OR EXCLUSION OF ANY PARTICULAR ITEMS FROM THE PROJECT.2. THE PLANS ARE DIAGRAMMATIC AND INDICATE ONLY THE SIZE AND GENERAL ARRANGEMENT OF PIPING AND EQUIPMENT. EXACT LOCATION OF ALL ELEMENTS SHALL BE DETERMINED AS WORK PROGRESSES, IN COOPERATION AND COORDINATION WITH THE WORK OF ALL TRADES. THEY ARE NOT INTENDED TO SHOW EVERY ITEM OF WORK OR MINOR PIECE OF EQUIPMENT. CONTRACTOR SHALL FURNISH AND INSTALL WITHOUT ADDITIONAL REMUNERATION ANY COMPONENT NECESSARY TO COMPLETE THE SYSTEM IN ACCORDANCE WITH THE BEST PRACTICE OF THE TRADE.3. ITEMS OF WORK OR EQUIPMENT SHOWN ON THE DRAWINGS ONLY, OR CALLED FOR IN THE SPECIFICATIONS ONLY, SHALL BE FURNISHED AND INSTALLED IN THE SAME MANNER AS IF THEY APPEARED ON BOTH THE DRAWINGS AND THE SPECIFICATIONS.4. DRAWINGS DO NOT INDICATE ALL OFFSETS, CHANGES IN ELEVATION, ETC. WHICH MAY BE REQUIRED. THE CONTRACTOR SHALL MAKE SUCH CHANGES IN PIPING AND LOCATION OF EQUIPMENT, ETC. TO ACCOMMODATE WORK, OBSTACLES, AND WORK OF OTHER CONTRACTORS.5. INSTALL EQUIPMENT AND PIPING TO AVOID INTERFERENCE WITH THE OPERATION, SERVICE, AND MAINTENANCE OF EQUIPMENT.6. ALL COSTS FOR CUTTING, PATCHING, AND PAINTING OF EXISTING WALLS, CEILINGS AND FLOORS TO ACCOMMODATE THE INSTALLATION OF WORK SHALL BE THE RESPONSIBILITY OF THE REFRIGERATION CONTRACTOR UNLESS INDICATED OTHERWISE. MATERIALS FOR RESTORATION OF EXISTING SURFACES SHALL MATCH THE EXISTING SURFACES.7. PIPES AND/OR DUCTS PENETRATING FIRE WALLS AND FLOORS SHALL BE FIRESTOPPED AS SPECIFIED. REFER TO CONTRACT DOCUMENTS FOR FIRE WALL AND FLOOR LOCATIONS.8. ALL PHYSICAL ATTRIBUTES OF EQUIPMENT AND DEVICES ARE BASED ON THOSE MANUFACTURERS LISTED IN THE SPECIFICATIONS AND/OR THE EQUIPMENT SCHEDULES. THE RESPECTIVE CONTRACTORS ARE RESPONSIBLE FOR ALL CHANGES BROUGHT ABOUT BY USE OF ITEMS BY OTHER MANUFACTURERS. THE ARCHITECT/ENGINEER HAS RESERVED THE RIGHT TO REJECT ITEMS BY OTHER MANUFACTURERS IF THOSE ITEMS DO NOT MATCH THE PHYSICAL ATTRIBUTES, CAPACITIES, FEATURES, OR OVERALL VALUE TO THE PROJECT OF THE MANUFACTURERS LISTED.9. DESIGN AND INSTALLATION SHALL FOLLOW ALL APPROPRIATE CODES AND STANDARDS. INCLUDING, BUT NOT LIMITED TO, THE INTERNATIONAL MECHANICAL CODE, 2015.REDUCERDETAIL DESIGNATIONPOINT OF CONNECTIONSECTION DESIGNATIONVALVE MANIFOLD, REFER TO DETAIL INDICATED ON PLAN VIEWAM311REFERENCE DRAWINGDETAILP-1AREFERENCE DRAWINGSECTION NUMBERPIPE ANCHOR (PA)PIPE GUIDE (PG)PRESSURE GAUGECIRCULATING PUMPFLEXIBLE CONNECTORDIRECTION OF FLOWCLEANOUT (FLOOR/WALL)WATER HAMMER ARRESTOR (X INDICATES PDI SIZE)DIRECTION OF DOWNWARD PITCHPRESSURE/TEMPERATURE TAPTHERMOMETERMETERUNIONHOSE BIBBCIRCUIT NO. & NAME (B, C, E)CIRCUIT NO., SEE SCHEDULE, M301RETURN PIPE SIZE, INCHESSUPPLY PIPE SIZE, INCHESDEFROST PIPE SIZE, INCHESCIRCUIT NO. & NAMECIRCUIT NO., SEE SCHEDULE, M301GLYCOL FLOWSHUT-OFF VALVE IN RISERSHUT-OFF VALVE (BALL, BUTERFLY, ETC.)BALANCING VALVE (X INDICATES GPM)ELBOW - TURNED UPELBOW - TURNED DOWNRELIEF VALVE (X INDICATES P - PRESSURE T - TEMPERATURE PT - COMBINATION PRESS./TEMP.)BRANCH CONNECTION - TOPBRANCH CONNECTION - BOTTOMCAPGLOBE VALVECHECK VALVESTRAINERCIRCUIT NO., SEE SCHEDULE, M301LIQUID SUPPLY PIPE SIZE, INCHESSUCTION PIPE SIZE, INCHESSUCTION RISER SIZE, INCHESCIRCUIT NO. & NAME (A, D)REFRIGERANTABOVEABVABOVE FINISHED FLOORAFFAMERICAN GAS ASSOCIATIONAGAAQUASTATAQSTARCHITECT(URAL)ARCHARCHITECT/ENGINEERA/EAUTOMATICAUTOAUTOMATIC AIR VENTAAVBALANCING VALVE BAL VBALL VALVE BVBELOW BLWBELOW FINISHED FLOOR BFFBRAKE HORSEPOWER BHPBRITISH THERMAL UNIT BTUBRITISH THERMAL UNITS(1000)PER HOUR MBHBRITISH THERMAL UNITS PER HOUR BTUHBUILDING BLDGBUTTERFLY VALVE BFVBY OWNER BOCHECK VALVE CKVACHLORINATED POLYVINYL CHLORIDE CPVCCIRCULATING PUMP CPCONNECTION CONNCONTRACT LIMIT LINE CLLCONTRACT(OR) CONTRCOPPER CUDETAIL DTLDOWN DNDRAIN DRDOUBLE SUCTION RISER DSRDRAWING DWGELECTRIC(AL) ELECELECTRONIC STEPPER REGULATOR ESRENGINEER ENGRENTERING WATER TEMPERATURE EWTEQUIPMENT EQUIPEQUIPMENT BY OWNER EBOEXISTING EXSTEXTERIOR EXTFACTORY MUTUAL FMFEET (FOOT) FTFEET PER MINUTE FPMFEET PER SECOND FPSFIRE PROTECTION FPFLEXIBLE FLEXFLEXIBLE CONNECTION FLEX CONNFLOOR DRAIN FDGAGE (GAUGE) GAGALLON GALGALLON PER DAY GPDGALLON PER HOUR GPHGALLONS PER MINUTE GPMGATE VALVE GVGLYCOL HEAT RECLAIM LOOP SUPPLY PIPE GHRSGLYCOL HEAT RECLAIM LOOP RETURN PIPE GHRRHEATING, VENTILATION, AIR CONDITIONING HVACHORSEPOWER HPINCH(ES) ININCHES WATER GAUGE IN W.G.INDUSTRIAL RISK INSURERS IRIINSIDE DIAMETER IDINSTUMENT AIR IAIRON PIPE SIZE IPSKILOWATT KWKILOWATT HOUR KWHMANUFACTURER MFRMATCHLINE MLMECHANICAL MECHMECHANICAL JOINT MJMETER MMIXING VALVE MIX VMODEL MODNORMALLY CLOSED N.C.NORMALLY OPEN N.O.NOT TO SCALE NTSOUTSIDE DIAMETER ODPLUMBING PLMPOLYVINYL CHLORIDE PVCPOUNDS PER SQUARE FOOT PSFPOUNDS PER SQUARE INCH PSIPOUNDS PER SQUARE INCH ABSOLUTE PSIAPOUNDS PER SQUARE INCH GAGE PSIGPRESSURE DROP PDPRESSURE REDUCING VALVE PRVPRESSURE TEMPERATURE REKIEF VALVE PTRVPUMP PPOWERHOUSE PHREDUCED PRESSURE ZONE RPZREVOLUTIONS PER MINUTE RPMRISER RSCHEDULE SCHEDSECTION SECTSPECIFICATIONS SPECSQUARE FOOT SQ FTSQUARE INCH SQ INSATURATED SUCTION TEMPERATURE SSTTEMPERATURE TEMPTRAP TTYPICAL TYPUTILITY UTILVACUUM BREAKER VBWATER HAMMER ARRESTOR WHAWITH W/WITHOUT W/O1A CO2XX7/8", 7/8"XXPTPMHBPWHA-XPEXISTING PIPEPIPE TO BE DEMOLISHEDNEW PIPEPOINT OF DISCONNECTIONDINSULATION SCHEDULELIQUIDALLALL1,2,4,5,61/2"COOLANTTYPESYSTEMSYSTEMTEMP.(DEG. F)REMARKSINSULATIONSIZEREMARKS:SUCTION 1,3,4,5,6(2) 1/2"1. PIPE INSULATION SHALL BE AP ARMAFLEX SS (SELF SEAL) OR T (EASY SLIDER) TYPE.2. SEAMS IN SINGLE LAYER APPLICATIONS SHALL FACE UP.3. STAGGER SEAMS IN MULTIPLE LATER APPLICATIONS.4. SEAMS SHALL BE SEALED WITH COMPAC INSULATION TAPE, #135 BLACK COLOR.5. CORNERS SHALL BE MITERED.6. INSULATION THICKNEESS SHALL COMPLY WITH ALL STATE AND LOCAL CODES.R-404AR-404A145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional SealSCALE:Store No:PRICING SET:PERMIT SET:CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.NONE7/1/2019 11:45:46 AMC:\Users\cooneys\Documents\071_Ithaca_MECH_CENTRAL_2017_CooneyS.rvtITHACAM300OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET07/03/19MWSC500 SOUTH MEADOW STITHACA, NY 14850#071NA07/03/2019TBDSYMBOLS, LEGENDS, NOTES AND SCHEDULERevision Schedule#Date Revision1 07/03/19 Permit SetREF037/071-5266 1. CONTRACTORS SHALL INSPECT THE SITE BEFORE SUBMITTING A BID PROPOSAL TO ENSURE KNOWLEDGE OF PROJECT REQUIREMENTS AND SITE CONDITIONS. IF NO CLARIFICATION IS REQUESTED, IT WILL BE CONSIDERED THAT THE CONTRACTORS ARE IN FULL UNDERSTANDING OF PROJECT REQUIREMENTS. 2. PROVIDE LABOR, SUPERVISION, EQUIPMENT, MATERIALS, AND SERVICES REQUIRED FOR THE COMPLETE INSTALLATION OF THIS WORK IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE, AND LOCAL CODES, AUTHORITIES HAVING JURISDICTION, AND STANDARDS INCLUDING BUT NOT LIMITED TO, SMACNA, ASHRAE, IBC, NEC, AND NFPA. 3. NOTHING CONTAINED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS SHALL BE CONSTRUED TO BE IN CONFLICT WITH ANY STATE OR LOCAL CODES, ORDINANCES OR REGULATIONS. 4. EQUIPMENT AND MATERIALS SHALL BE INSTALLED BY SKILLED TRADESMEN, FAMILIAR WITH THE COMPONENTS TO BE INSTALLED, AND IN ACCORDANCE WITH BEST PRACTICES OF THE INDUSTRY AND WEGMANS STANDARD PRACTICE. 5. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS, AND ACCESSORIES THAT MAY BE REQUIRED. THIS CONTRACTOR SHALL CAREFULLY EXAMINE THE ARCHITECTURAL; STRUCTURAL; HEATING, VENTILATING AND AIR- CONDITIONING; ELECTRICAL; PLUMBING; AND OTHER PROJECT DOCUMENTS AS MAY BE NECESSARY FOR PROPER OPERATION OR INSTALLATION AND SHALL PROVIDE OFFSETS, FITTINGS, AND ACCESSORIES TO MEET PROJECT CONDITIONS. 6. DIMENSIONS, CLEARANCES, AND LOCATIONS OF EQUIPMENT AND MATERIALS SHALL BE FIELD VERIFIED PRIOR TO ORDERING, PROCURING AND FURNISHING SAME. 7. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR DAMAGE TO THE BUILDING, PIPING OR EQUIPMENT THAT IS THE RESULT OF WORK FOR INSTALLATION OF THIS CONTRACT. 8. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR PATCH AND REPAIR OF ALL SURFACES TO MATCH EXISTING MATERIALS AND ADJACENT FINISHES ASSOCIATED WITH INSTALLATION/REMOVAL OF THIS WORK UNLESS SPECIFICALLY NOTED OTHERWISE. 9. WORK SHALL BE COMPLETED TO MAINTAIN ALL NECESSARY AND REQUIRED CLEARANCES, ACCESSES, AND OPENINGS, SUCH THAT FULL FUNCTIONALITY, PROPER OPERATION, AND REPAIR AND MAINTENANCE ARE ENSURED. 10. WHERE DEVICE MOUNTING OCCURS IN BRICK, TILE, OR BLOCK WALLS, THEY SHALL BE MOUNTED AT A VERTICAL MASONRY JOINT & IN EITHER THE TOP OR BOTTOM HORIZONTAL JOINT, CLOSEST TO THE MOUNTING HEIGHT. 11. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE LABELED AND LISTED BY A CERTIFIED TESTING LABORATORY OR AGENCY. 12. ALL CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK WITH OTHER CONTRACTORS BEFORE PERFORMING ANY WORK. 13. EXCEPT AS SPECIFICALLY NOTED, ALL MATERIALS AND EQUIPMENT FOR THIS SCOPE OF WORK SHALL BE NEW AND IN CONFORMANCE WITH WEGMANS' SPECIFICATIONS. 14. PROVIDE ALL MATERIAL, LABOR AND EQUIPMENT TO PERFORM COMPLETE SCOPE OF WORK RESULTING IN OPERABLE MECHANICAL, PLUMBING AND FIRE PROTECTION SYSTEMS AS INDICATED IN THE DOCUMENTS, WEGMANS' SPECIFICATIONS AND APPLICABLE LOCAL CODES. 15. CONTRACTOR IS RESPONSIBLE FOR PERFORMING PRELIMINARY AND FINAL TESTING OF ALL SCOPE ITEMS TO INCLUDE, BUT NOT BE LIMITED TO, HYDRAULIC TESTING, LEAK TESTING, FUNCTIONAL TESTING AND SYSTEM COMMISSIONING. OWNER TO BE NOTIFIED IN ADVANCE OF FUNCTIONAL TESTING AND SYSTEM COMMISSIONING. COMMISSIONING SHALL BE IN ACCORDANCE WITH THE WEGMANS' COMMISSIONING MANUAL. 16. CONTRACTOR MUST FURNISH EQUIPMENT AND MATERIAL SUBMITTALS FOR APPROVAL PRIOR TO ANY INSTALLATION. 17. CONTRACTOR TO PROVIDE OWNER WITH HARDCOPY AND CD OF OPERATIONS AND MAINTENANCE (O & M) MANUALS FOR ALL EQUIPMENT INCLUDED IN THIS SCOPE OF WORK. 18. MAKE FINAL PIPE CONNECTIONS TO ANY EQUIPMENT IN SCOPE WITH ISOLATION VALVES AND UNIONS OR FLANGES TO ENABLE SERVICING OR REPLACEMENT. 19. WHEREVER POSSIBLE, PIPING AND DUCTWORK SHALL BE INSTALLED EITHER PARALLEL OR PERPENDICULAR TO BUILDING STRUCTURAL AND ARCHITECTURAL ELEMENTS. 20. PROVIDE CODE APPROVED SEISMIC RESTRAINTS FOR PIPING AND EQUIPMENT WHERE REQUIRED BY SEISMIC ZONE. 1. THE DEMOLITION PLANS AND NOTES HAVE BEEN PREPARED TO ASSIST THE CONTRACTORS IN IDENTIFYING THE AREAS AND ITEMS OF DEMOLITION AND RENOVATION ASSOCIATED WITH THIS PROJECT. THE INFORMATION PROVIDED IS NOT MEANT TO BE ALL-INCLUSIVE IN TERMS OF LISTING EACH AND EVERY SPECIFIC TASK TO BE PERFORMED. EACH CONTRACTOR WILL THOROUGHLY EXAMINE ALL CONTRACT DOCUMENTS PRIOR TO PERFORMING ANY WORK. 2. DEMOLITION WORK INCLUDES, BUT IS NOT LIMITED TO, THE ITEMS INDICATED ON THE DEMOLITION DRAWINGS AND DESCRIBED IN THE DEMOLITION NOTES. THE EXTENT OF THE DEMOLITION WORK SHALL INCLUDE ALL WORK REQUIRED TO COMPLETE THE PROJECT AS INDICATED ON THE DRAWINGS. 3. THE OWNER HAS THE OPTION TO RETAIN POSSESSION OF ANY REMOVED MATERIALS OR EQUIPMENT. ALL SUCH ITEMS SHALL BE CAREFULLY REMOVED AND STORED AT THE SITE BY THE CONTRACTOR WHERE DIRECTED BY THE OWNER. ANY MATERIALS OR EQUIPMENT NOT RETAINED BY THE OWNER WILL BECOME THE RESPONSIBILITY OF THE CONTRACTOR FOR DISPOSAL AND PROMPTLY REMOVED FROM SITE. 4. ANY CONTRACTOR REMOVING OR MODIFYING MATERIAL CONTAINING ASBESTOS OR SUSPECTED OF CONTAINING ASBESTOS WILL NOTIFY THE OWNER AT ONCE AND STOP REMOVAL. IDENTIFICATION AND/OR REMOVAL OF ASBESTOS CONTAINING MATERIAL WILL BE THE RESPONSIBILITY OF THE OWNER. 5. REFER TO ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR DEMOLITION WORK BY RESPECTIVE CONTRACTORS. EACH CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION ASSOCIATED WITH HIS CONTRACT AND SCOPE OF WORK. EACH CONTRACTOR IS RESPONSIBLE TO PATCH AND/OR REPAIR ANY AND ALL CONSTRUCTION AFFECTED BY HIS DEMOLITION. THE EXTENT OF PATCH AND REPAIR SHALL BE AS REQUIRED TO RECEIVE THE SCHEDULED NEW WORK 1. THIS CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS STEEL AND SUPPORTS TO SUSPEND DUCTWORK, PIPING AND EQUIPMENT. 2. ALL EQUIPMENT WITH ROTATING OR RECIPROCATING ELEMENTS SHALL BE INSTALLED WITH VIBRATION ISOLATORS. 3. THE MECHANICAL CONTRACTOR SHALL SEAL ALL HIS RESPECTIVE WALL AND ROOF PENETRATIONS. COORDINATE WITH WEGMANS' CONSTRUCTION WITH RESPECT TO ROOFING WARRANTEES. 4. THE MECHANICAL CONTRACTOR SHALL PAY FOR ALL FEES AND PERMITS AS NECESSARY TO COMPLETE THE INSTALLATION OF THE SYSTEMS WITHIN THEIR SCOPE OF WORK 5. THE MECHANICAL CONTRACTOR SHALL PROVIDE MANUAL AIR VALVES AT ALL HIGH POINTS IN HYDRONIC SYSTEMS AND AT EACH UNIT TO FACILITATE MANUAL VENTING. PROVIDE 3/4" VALVES WITH HOSE END DRAINS (WITH CAP & CHAIN), AT ALL LOW POINTS TO FACILITATE DRAINAGE. 6. ALL REFRIGERATION PIPING SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. ALL PIPE SIZES SHALL BE PER MANUFACTURER'S REQUIREMENTS BASED ON PROPOSED PIPE ROUTING AND EQUIPMENT LOCATIONS. 7. ALL REFRIGERANT SUCTION PIPING SHALL BE PITCHED A MINIMUM OF 1/4" IN 10'-0" IN THE DIRECTION OF THE REFRIGERANT FLOW. 8. ALL PENETRATIONS THROUGH CHASES, WALLS, OR FLOORS WHICH ARE FIRE-RATED SHALL BE PROPERLY SEALED TO MAINTAIN RATING. 9. ALL DUCTS THAT PENETRATE CHASES, WALLS, OR FLOORS WHICH ARE FIRE-RATED SHALL BE INSTALLED WITH FIRE DAMPERS IN ACCORDANCE WITH NFPA 90A. THIS APPLIES EVEN IF THEY ARE NOT SPECIFICALLY SHOWN ON THE DRAWINGS. 10. ALL DUCTWORK, EQUIPMENT, PIPING, ETC. SHALL BE INSTALLED ABOVE THE FINISHED CEILING UNLESS SPECIFICALLY NOTED OTHERWISE. 11. ALL DUCTWORK SIZES NOTED ARE FREE AREA SIZES. 12. TURNING VANES SHALL BE PROVIDED IN ALL RECTANGULAR ELBOWS, EXCEPT KITCHEN AND DISHWASHER EXHAUST. 13. SPLITTERS AND BALANCING DAMPERS SHALL BE PROVIDED AT ALL DUCT BRANCHES, EXCEPT KITCHEN EXHAUST. 14. LENGTH OF FLEXIBLE DUCT BRANCHES SHALL NOT EXCEED 5'-0" MAXIMUM AND SHALL BE SUPPORTED SO AS TO PREVENT SAGGING WHICH RESTRICTS AIR FLOW. ADDITIONAL LENGTH FOR INDIVIDUAL CONNECTIONS SHALL BE RIGID ROUND SHEET METAL DUCTWORK. 15. FLEXIBLE DUCT SHALL NOT BE ACCEPTABLE FOR EXHAUST SYSTEM INSTALLATIONS. 16. FABRICATE AND INSTALL ALL DUCTWORK IN ACCORDANCE WITH LATEST SMACNA STANDARDS: "HVAC DUCT CONSTRUCTION STANDARDS; METAL AND FLEXIBLE". 17. ALL CONTROL WIRING SHALL COMPLY WITH NEC AND WEGMANS' SPECIFICATIONS. 18. ALL AIR CONDITIONING CONDENSATE DRAINS SHALL BE FURNISHED WITH APPROPRIATELY SIZED P-TRAPS AND GRAVITY PIPED TO INDIRECT CONNECTION TO DRAINS. 19. PROVIDE BACKFLOW PROTECTION FOR ANY DOMESTIC WATER CONNECTIONS TO MECHANICAL EQUIPMENT. 20. PROVIDE SERVICES OF TESTING AND BALANCING AGENT WHO IS A MEMBER OF EITHER AABC OR NEBB TO PERFORM TAB WORK TO BRING SYSTEMS IN SCOPE IN COMPLIANCE WITH DESIGN. PROVIDE AIR BALANCE REPORT UPON COMPLETION OF WORK. 21. PROVIDE DUCT AND PIPE INSULATION IN COMPLIANCE WITH LOCAL ENERGY CODE. FURNISH AND INSTALL PER WEGMANS' REFRIGERATION SPECIFICATION AND ASHRAE STANDARDS. 22. PROVIDE SMACNA APPROVED ACCESS DOORS IN DUCTWORK FOR ACCESS TO ALL SMOKE DETECTORS, FIRE, SMOKE AND COMBINATION DAMPERS,COILS AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE. 23. PROVIDE FULL PORT FLANGED OR THREADED VALVES WHERE INDICATED OR REQUIRED. HYDRAULIC VALVES 2"∅AND SMALLER SHALL BE 3-PIECE BALL VALVES. HYDRAULIC VALVES 2-1/2"∅AND LARGER MAY BE BUTTERFLY, GATE OR BALL VALVES. 24. PIPING USED FOR REFRIGERATION SYSTEMS SHALL BE DRAWN-TEMPER COPPER TUBE, ASTM B280, TYPE ACR WITH WROUGHT COPPER FITTINGS, UNLESS OTHERWISE NOTED. 25. PIPING USED FOR HYDRONIC GLYCOL SYSTEMS SHALL BE DRAWN-TEMPER COPPER TUBE, ASTM B88, TYPE L WITH WROUGHT COPPER FITTINGS, UNLESS OTHERWISE NOTED. 26. PIPING USED FOR NATURAL GAS SYSTEMS SHALL BE STEEL, ASTM A53, TYPE E OR S, GRADE B, SCHEDULE 40 BLACK WITH THREADED, MALLEABLE-IRON OR STEEL WELDED FITTINGS. 27. INSTALL THE FOLLOWING PIPE ATTACHMENTS: a. UNISTRUT MOUNTED HANGERS FOR MULTIPLE HORIZONTAL PIPING SUPPORTED ON A TRAPEZE. b. SUPPORT VERTICAL RUNS WITH 1-5/8" UNISTRUT CHANNEL. c. INSTALL ARMAFIX IPS INSULATION WITH EITHER POLYPROPYLENE COPOLYMER OR GALVANIZED PIPE SHIELDS. d. INSTALL ARMAFLEX INSULATION WITH POLYPROPYLENE COPOLYMER PIPE SHIELDS. 28. INSULATE PIPING PER INSULATION SCHEDULE (THIS DRAWING). 1. PLUMBING CONTRACTOR SHALL SCHEDULE AND PERFORM ALL TESTS, OBTAIN ALL PERMITS, INSPECTIONS AND CONNECTION FEES FOR PLUMBING INSTALLATION. 2. PVC WASTE AND VENT PIPE SHALL BE SOLID WALL STANDARD ASTM D 1785, ASTM D 2665., SCHEDULE 40. 3. PVC FITTINGS SHALL BE ASTM D 2665 SOCKET TYPE MADE TO ASTM D 3311 WASTE AND VENT PATTERNS, SCHEDULE 40. FOR ALL CONCEALED PIPING LOCATED IN CABINETS OR UNDER COUNTERS SERVING LAVATORIES, HAND SINKS, PREP SINKS, 2, 3 AND 4 BAY SINKS USE THE FOLLOWING: a. 3/4 TO 1-½ INCH NPS (DN32 AND DN40): DWV COPPER, SOLDERED JOINTS AND FITTINGS. b. 2 TO 4 INCH NPS (DN50 TO DN100): DWV COPPER, SOLDERED JOINTS AND FITTINGS FOR ALL OTHER CONCEALED PIPING UNDER REFRIGERATED CASES, IN WALLS AND CHASES: a. 1/2 TO 1 ½ INCH NPS (DN20 AND DN40): PVC PLASTIC PIPE, PVC SOCKET FITTINGS, AND SOLVENT-CEMENTED JOINTS b. 2 TO 4 INCH NPS (DN50 TO DN100): PVC PLASTIC PIPE, PVC SOCKET FITTINGS, AND SOLVENT-CEMENTED JOINTS. UNDERGROUND, SOIL, WASTE, AND VENT PIPING: USE THE FOLLOWING PIPING MATERIALS FOR EACH SIZE RANGE: a. NPS 1-1/2 (DN 40): PVC PIPE, PVC SOCKET FITTINGS, AND SOLVENT-CEMENTED JOINTS. b. NPS 2 TO NPS 4 (DN 50 TO DN 100): PVC PIPE, PVC SOCKET FITTINGS, AND SOLVENT-CEMENTED JOINTS. c. NPS 6 (DN 150) PVC PIPE, PVC SOCKET FITTINGS AND SOLVENT CEMENTED JOINTS. d. NPS 8 (DN 200) PVC PIPE, PVC SOCKET FITTINGS AND SOLVENT CEMENTED JOINTS (WITHIN BUILDING AND SITE PRIOR TO MANHOLE). e. NPS 8 (DN 200) SDR 35 PIPE, WITH BELL-AND-SPIGOT ENDS FOR GASKETED JOINTS WITH ELASTOMERIC SEALS. 4. CLEANOUT PLUGS SHALL BE PVC WITH COUNTER-SUNK HEAD. 1. INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF ALL LOCAL, STATE AND FEDERAL BUILDING CODES AND FM GLOBAL. 2. FIRE PROTECTION CONTRACTOR SHALL PREPARE, SUBMIT AND OBTAIN APPROVAL OF DRAWINGS AND HYDRAULIC CALCULATIONS FOR NEW AND EXISTING SPRINKLER SYSTEMS PRIOR TO START OF WORK. 3. COMPONENTS SHALL HAVE A MINIMUM WORKING PRESSURE OF 175 PSI. 4. SUBMIT PRODUCT DATA FOR APPROVAL FOR MATERIAL AND EQUIPMENT: a. MALLEABLE IRON: ASME B16.3, CLASS 300 STANDARD PATTERN. b. CAST IRON: ASME B16.4, CLASS 250 STANDARD PATTERN. c. GROOVED END: UL LISTED AND FM APPROVED, ASTM A536, GRADE 65-45-12 5. ALL PIPING 2" AND SMALLER SHALL BE MANUFACTURED IN THE USA, ASTM-A53 GRADES A AND B. SCH-40 BLACK STEEL, UL LISTED AND FM APPROVED. ALL PIPING LARGER THAN 2" SHALL BE BLACK STEEL, ASTM A135 GRADE A, SCH-10 UL LISTED AND FM APPROVED. MANUFACTURED IN THE USA. 6. VALVES SHALL BE UL LISTED AND FM -APPROVED WITH 175 PSI NON-SHOCK MINIMUM WORKING PRESSURE. a. GATE VALVES, 2" AND SMALLER: UL 262, CAST BRONZE, THREADED ENDS, SOLID WEDGE, OUTSIDE SCREW AND YOKE, RISING STEM. b. INDICATING VALVES, 2-1/2" AND SMALLER: BALL TYPE, BRONZE BODY WITH THREADED ENDS AND INTEGRAL INDICATING DEVICE. c. GATE VALVES, 2-1/2" AND LARGER: UL 262, IRON BODY,BRONZE MOUNTED, TAPER WEDGE, OUTSIDE SCREW AND YOKE, RISING STEM, FLANGED ENDS. d. GATE VALVES, 2-1/2" AND LARGER FOR UL 262, IRON BODY, BRONZE MOUNTED, SOLID WEDGE DISC, FOR USE WITH INDICATOR POSTS: NON-RISING STEM WITH OPERATING NUT AND FLANGED ENDS. e. SWING CHECK VALVES, 2-1/2" AND LARGER: UL 312, CAST IRON BODY AND BOLTED CAP, BRONZE OR CAST IRON DISC, BRONZE RING AND FLANGED ENDS. f. BALL DRIP VALVES: UL 1726, AUTOMATIC DRAIN VALVE, SPRING LOADED, BALL CHECK DEVICE WITH THREADED ENDS. g. REDUCED PRESSURE ZONE BACK FLOW PREVENTER ASSEMBLY: UL 312/ASSE 1013, CONSISTING OF OS&Y GATE VALVES ON INLET AND OUTLET. TEST COCKS, PRESSURE-DIFFERENTIAL RELIEF VALVE AND ASME A1121.2 AIRGAP FITTING LOCATED BETWEEN 2 POSITIVE SEATING CHECK VALVES. PROVIDE 3/4" BYPASS WITH DISPLACEMENT TYPE WATER METER, VALVES, AND REDUCED PRESSURE ZONE BACKFLOW PREVENTER, FOR CONTINUOUS PRESSURE APPLICATION. 7. AUTOMATIC SPRINKLERS SHALL HAVE HEAT RESPONSIVE ELEMENT CONFORMING TO UL 199. ORIENTATIONS AND TYPES SHALL BE AS INDICATED ON THE DRAWINGS. ALL SPRINKLERS IN FINISHED AREAS SHALL BE CHROME. 8. WATER MOTOR OPERATED ALARMS SHALL CONFORM TO UL 753. 19. WATER FLOW INDICATORS SHALL CONFORM TO UL 346, ELECTRICAL SUPERVISION TYPE, VANE TYPE WATER FLOW DETECTOR. INCLUDE 2 SPDT CIRCUIT SWITCHES TO PROVIDE ISOLATED ALARM AND AUXILIARY CONTACTS, COMPLETE WITH FACTORY SET, FIELD ADJUSTABLE RETARD ELEMENT TO PREVENT FALSE SIGNALS, AND TAMPER PROOF COVER WHICH SENDS SIGNAL WHEN COVER IS REMOVED. 9. PRESSURE SWITCHES SHALL CONFORM TO UL 753, WATER FLOW SWITCH WITH RETARD, ELECTRICAL SUPERVISION TYPE, SPDT, NORMALLY CLOSED CONTACTS, DESIGNED TO OPERATE ON PRESSURE RISE AND SIGNAL WATER FLOW. 10. SUPERVISORY SWITCH, UL 753 FOR VALVES AND INDICATOR POSTS, ELECTRICAL SUPERVISION TYPE, SPDT NORMALLY CLOSED CONTACTS, DESIGNED TO SIGNAL VALVE IS IN OTHER THAN FALL OPEN POSITION. SHOCK MINIMUM WORKING PRESSURE. 11. CONTRACTOR SHALL PROVIDE SPRINKLER HEADS CENTERED IN CEILING TILES. 12. UTILIZE ROUGH BRONZE UPRIGHT HEADS IN ALL UNFINISHED LOCATIONS. 13. PROVIDE AUXILIARY DRAINS AT ALL LOW POINTS IN PIPING. 14. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL DRAINS AND INSPECTOR'S TESTS WITH THE ARCHITECT. THE CONTRACTOR SHALL PIPE ALL DRAINS AND INSPECTOR'S TO PLUMBING DRAINS LOCATED IN UNFINISHED AREAS. THE CONTRACTOR SHALL PROVIDE ALL ACCESS PANELS NECESSARY FOR DRAIN VALVE AND INSPECTOR'S TESTS. GENERAL NOTES: GENERAL DEMOLITION NOTES: HVAC & REFRIGERATION NOTES: PLUMBING NOTES: FIRE PROTECTION NOTES: 5. DWV COPPER PIPE SHALL BE ASTM B306 DRAINAGE TUBE, DRAWN TEMPER. 6. DWV COPPER FITTINGS SHALL BE ASME B16.23, CAST COPPER OR ASME B16.29, WROUGHT COPPER SOLDER JOINT. 7. PIPING APPLICATIONS: ABOVEGROUND SOIL, WASTE (INCLUDING HAND SINKS, WORK SINKS, 2 AND 3 BAY SINKS, PREP SINKS, ICE-MACHINES, BEVERAGE STATIONS, OVENS, PROFFERS, WATER HEATERS, ETC.) AND CONDENSATE DRAINAGE (EVAPORATOR COILS, REFRIGERATORS, FREEZERS, REFRIGERATED CASES, ACR UNITS AND OTHER AIR HANDLING EQUIPMENT) AND USE THE FOLLOWING: FOR ALL EXPOSED PIPING: a. 3/4 TO 1 ½ INCH NPS (DN32 AND DN40): DWV COPPER, SOLDERED JOINTS AND FITTINGS. b. 2 TO 4 INCH NPS (DN50 TO DN100): DWV COPPER, SOLDERED JOINTS AND FITTINGS. c. 5 AND 6 INCH NPS (DN125 AND DN150): DWV COPPER, SOLDERED JOINTS AND FITTINGS. EXPOSED PIPING SHALL HAVE ALL LABELING REMOVED. 8. WATER PIPE SHALL BE COPPER TUBE, ASTM B-88, TYPE L, DRAWN TEMPER, FOR ABOVE GRADE SERVICE, AND TYPE K, ANNEALED TEMPER, FOR BELOW GRADE SERVICE. 9. WATER PIPE FITTINGS SHALL BE WROUGHT COPPER SOLDER JOINT FITTINGS, ANSI B16.27 STREAM LINED PATTERN. 10. UTILIZE DIELECTRIC UNIONS TO ISOLATE DISSIMILAR METALS. UTILIZE ASTM B32, 95-5 TIN ANTIMONY SOLDER FOR BOTH WATER AND WASTE, WATER AND VENT SOLDERING. 11. UTILIZE BRASS BODY GATE AND BALL VALVES FOR GENERAL DUTY VALVES. GATE VALVES SHALL BE AS MANUFACTURED BY NIBCO 211 SERIES, OR EQUAL. BALL VALVES SHALL BE AS MANUFACTURED BY WATTS, B-6000 SERIES, OR EQUAL. ALL GAS FIRED APPLIANCES SHALL BE PROVIDED WITH UL/FM LISTED LOCKABLE GAS VALVES MILWAUKEE BA-475B OR EQUAL; IN ADDITION SUCH VALVES SHALL BE INSTALLED UPSTREAM OF GAS SOLENOID AND ANSUL VALVES CONTROLLING GAS SUPPLY TO APPLIANCES INSTALLED UNDER EXHAUST HOODS. 12. PROVIDE BELLOWS TYPE, STAINLESS STEEL CASING AND BELLOWS, 250 PSI RATED WATER HAMMER ARRESTORS, TESTED AND CERTIFIED IN ACCORDANCE WITH PDI STANDARD WH-201. 13. PROVIDE CHROMED ANGLE STOP LAVATORY AND SINK SUPPLIES, 1/2" COPPER INLET BY 3/8" INCH OUTLET. 14. PROVIDE LAVATORY AND SINK TRAPS AND WASTES OF POLISHED CHROME PLATED, TUBULAR BRASS, 17 GAGE, WITH BRASS NUTS ON SLIP INLETS. 15. NSULATE ALL DOMESTIC HOT AND COLD WATER LINES WITH 1" PREFORMED FIBERGLASS INSULATION WITH CLOTH JACKET. INSULATE ALL HOT AND COLD WATER VALVES AND FITTINGS WITH 1" PREFORMED FIBERGLASS INSULATION AND PREFORMED PVC COVERS. 16. PROVIDE TRAP PRIMER ON ALL EQUIPMENT & FLOOR DRAINS WHEN REQUIRED BY LOCAL JURISDICTION. 17. EQUIPMENT AND MATERIAL TO BE IN ACCORDANCE WITH WEGMANS PLUMBING SPECIFICATIONS. 18. ALL SANITARY PIPING IS SLOPED AT 1/8" PER FOOT UNLESS OTHERWISE NOTED. PROVIDE 4" MINIMUM SANITARY CLEANOUTS ON ALL 90 DEGREE CHANGES IN DIRECTION. PLUMBING NOTES (CONTINUED): INSULATION SCHEDULE GLYCOL DX DX SUPPLY & RETURN SUCTION LIQUID ALL ALL ALL 1,2,4,5,6 1,3,4,5,6 1,2,4,5,6 (2) 1/2" 3/4" 1/2" TYPE COOLANT GLYCOL SUPPLY & RETURN SYSTEM ALL TEMP. (DEG. F) SYSTEM NOTES 1,2,4,5,6 INSULATION SIZE 3/4" NOTES: 1. PIPE INSULATION SHALL BE AP ARMAFLEX SS (SELF SEAL) OR T (EASY SLIDER) TYPE. 2. SEAMS IN SINGLE LAYER APPLICATIONS SHALL FACE UP. 3. STAGGER SEAMS IN MULTIPLE LAYER APPLICATIONS. 4. ALL SEAMS TO BE SEALED WITH ARMAFLEX INSULATION ADHESIVE. IN ADDITION BUTT SEAMS SHALL BE SEALED WITH BLACK INSULATON TAPE. REFER TO SPECIFICATIONS FOR APPROVED MANUFACTURERS. 5. CORNERS SHALL BE MITERED. 6. INSULATION THICKNESS SHALL COMPLY ALL STATE AND LOCAL CODES. LEGEND -POINT OF DEMOLITION -EXISTING TO REMAIN -NEW WORK -POINT OF CONNECTION -REVISION CLOUD -EXISTING TO BE REMOVED P D 145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.NONE7/2/2019 2:45:17 PMC:\Users\monom\Documents\071_Ithaca_PLUMB_CENTRAL_2017_monomCVV2R.rvtITHACAM001OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 MJWMSM500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/2019 TBD DRAWING MOUNTED SPECSRevision Schedule # Date Revision 1 07/03/19 PERMIT SET 071-5233 145 Culver Road, Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.com145 Culver Road Suite 200Rochester, NY 14620Telephone 585 427 8888Facsimile 585 427 8914www.erdmananthony.comProject No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.Professional Seal SCALE:Store No: PRICING SET: PERMIT SET: CONST SET:CCOPYRIGHT 2019 BY WEGMANS FOOD MARKETS INC., ALL RIGHTS RESERVED THESE DOCUMENTS ARE THE PROPERTY OF WEGMANS FOOD MARKETS INC. NO DUPLICATION IS PERMITTED WITHOUT WRITTEN APPROVAL FROM WEGMANS FOOD MARKETS INC.NOTICE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. NO REVISIONS ARE PERMITTED UNLESS AUTHORIZED BY THE ENGINEER OF RECORD.NONE7/2/2019 2:45:16 PMC:\Users\monom\Documents\071_Ithaca_PLUMB_CENTRAL_2017_monomCVV2R.rvtITHACAM000OLDE WORLD CHEESE REMODEL071-5266/971-3807/03/19PERMIT SET 07/03/19 MJWMSM500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/2019 TBD TITLE SHEET071-5266 OLDE WORLD CHEESE REMODEL ITHACA #071 500 SOUTH MEADOW STREET ITHACA, NY 14850 M501 BELOW GRADE STORM, SANITARY AND VENT PLAN M501_6 QUADRANT 6 BELOW GRADE STORM, SANITARY AND VENT PLAN M506 ABOVE GRADE STORM, SANITARY AND VENT PLAN M506_2 QUADRANT 2 ABOVE GRADE STORM, SANITARY AND VENT PLAN M508 DOMESTIC WATER SERVICE PLAN M508_2 QUADRANT 2 DOMESTIC WATER SERVICE PLAN M506D ABOVE GRADE STORM, SANITARY AND VENT DEMO PLAN M506D_2 QUADRANT 2 ABOVE GRADE STORM, SANITARY AND VENT DEMO PLAN M508D DOMESTIC WATER SERVICE DEMO PLAN M508D_2 QUADRANT 2 DOMESTIC WATER SERVICE DEMO PLAN M400A REFRIGERATION CONTROLS NETWORK ARCHITECTURE AND LEGENDS M400B REFRIGERATION CONTROLS NETWORK ARCHITECTURE AND LEGENDS M401 REFRIGERATION CONTROLS PLAN M401_2 QUADRANT 2 REFRIGERATION CONTROLS PLAN M300 SYMBOLS, LEGENDS, NOTES AND SCHEDULE M301 REFRIGERATION SCHEDULE M302 REFRIGERATION PIPING PLAN M302_2 QUADRANT 2 REFRIGERATION PIPING PLAN M308 REFRIGERATION DETAILS M001 DRAWING MOUNTED SPECS REFRIGERATION CONTROLS DRAWINGS REFRIGERATION DRAWINGS PLUMBING DRAWINGS AREA OF WORK Revision Schedule # Date Revision 1 07/03/19 PERMIT SET 071-5233 MC1-3A 10-CAS0239 MC1-4C 10-CAS0239 MC1-20A 10-CAS0299 MC1-20B 10-CAS0299 MC1-7A 10-WPR0002 MC1-7B 10-CAS0239 MC1-3C (2)#10,#10EG 10-CAS0300 MC1-3B (2)#10,#10EG 10-CAS0300 10-SCL0067 10-SCL0067 MC1-20C 10-CTB CASE BUSDCUT MC1 10-CAS0298 BUSDCUT MC1 10-CAS0298 CDCD CD CD CD CD CD CD CD CD CD BUSDUCT P1 100ABUSDUCTMC1 100ATAPTAPMC1-3A 10-CAS0239 MC1-4C 10-CAS0239 MC1-20A 10-CAS0299 MC1-20B 10-CAS0299 MC1-7A 10-WPR0002 MC1-7B 10-CAS0239 MC1-3C (2)#10,#10EG 10-CAS0300 MC1-3B (2)#10,#10EG 10-CAS0300 10-SCL0067 10-SCL0067 MC1-20C 10-CTB CASE BUSDCUT MC1 10-CAS0298 BUSDCUT MC1 10-CAS0298 CDCD CD CD CD CD CD CD CD CD CD CD BUSDCUT MC1 10-CAS0298 BUSDCUT MC1 10-CAS0298 CDCD CD 5 5 E.4 1 1 1 1 2 1 3 1 1 2 5 5 E.4 MC1-7A MC1-20C BUSDUCT MC1 10-SCL0067 10-WPR0002 10-CTB CASE 10-SCL0067 2 2 1 1 KEY PLAN Bengineering, p.c.EC Phone: (585) 641-7121 Fax: (585) 362-4175 www.ec4b.com 15 Schoen Place Suite 300 Pittsford, NY 14534 DESIGN / BUILD CONTRACTOR760 BROOKS AVE ROCHESTER NY 14619PHONE 585-224-1111 FAX 585-434-3850billitierelectric.comBILLITIERELECTRICN Project No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.SCALE:AS NOTEDStore No: PRICING SET: PERMIT SET: CONST SET: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209.7/1/2019 11:52:29 AMC:\Users\adetorio\Documents\071 _Ithaca_ELECT_CENTRAL_2017_adetorioM3H83.rvtITHACA, NYER501OLDE WORLD CHEESE REMODEL071-52666/26/2019KAFAED500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/19 TBD POWER PLANS - DEMO AND NEWCONSTRUCTION WORK KEYED NOTES: 1. 2. PROVIDE CORD DROP ASSEMBLY FOR RELOCATED EQUIPMENT. PROVIDE COMPLETE CONNECTION TO EXISTING BRANCH CIRCUIT. EXTEND AS REQUIRED. PROVIDE NEW SCALE RECEPTACLE FOR RELOCATED SCALE. PROVIDE COMPLETE CONNECTION TO EXISTING BRANCH CIRCUIT. EXTEND AS REQUIRED. ELECTRICAL CONSTRUCTION GENERAL WORK NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. DESIGN IS BASED ON ASSUMPTION THAT THE EXISTING BRANCH CIRCUITING UTILIZES MULTIPLE CONDUCTOR CABLES THAT SERVE MORE THAN ONE (1) CIRCUIT WITH ONE NEUTRAL CONDUCTOR AND WHERE THE CIRCUIT BREAKERS ARE NOT TIED TOGETHER TO TRIP SIMULTANEOUSLY. THIS TYPE OF BRANCH CIRCUITING IS A NEC CODE VIOLATION. ALL EXISTING CIRCUITING THAT IS PART OF THIS REMODEL AND UTILIZES THIS TYPE OF CIRCUITING SHALL BE REMOVED AND REPLACED WITH CODE COMPLIANT BRANCH CIRCUITING. USING ADHESIVE BACKED PRINTED TAPE, LABEL ALL RECEPTACLES, SWITCHPLATES AND EQUIPMENT. LABELS SHALL LIST PANEL DESIGNATION AND CIRCUIT NUMBER. TAPE SHALL BE ATTACHED TO FACE OF RECEPTACLE AND/OR EQUIPMENT. ALL AFFECTED PANEL SCHEDULES SHALL BE UPDATED UPON COMPLETION OF PROJECT. PROVIDE AS BUILT DOCUMENTATION ACCURATELY SHOWING WHICH PANEL AND CIRCUIT EACH PIECE OF EQUIPMENT WAS FED FROM. IF REQUIRED, PROVIDE NEW CIRCUIT BREAKERS AND/OR BUSDUCT CIRCUIT BREAKER ENCLOSURES TO MATCH EXISTING MANUFACTURER CONSTRUCTION, KAIC RATING. NEW BREAKERS SHALL BE LISTED FOR USE WITH THE EXISTING PANELBOARD AND/OR BUSDUCT. MINIMUM CONDUCTOR SIZE SHALL BE (2)#12,(1)#12GND UNLESS NOTED OTHERWISE. ALL BRANCH CIRCUIT HOMERUNS (FROM EQUIPMENT/DEVICE TO PANELBOARD) SHALL BE UP-SIZED PER NEC IF DISTANCE EXCEEDS 100' FOR 120V CIRCUITS, 200' FOR 208V CIRCUITS. MAXIMUM ALLOWABLE VOLTAGE DROP FOR A BRANCH CIRCUIT IS 3 PERCENT. ALL 120V AND 277V, 1∅ NEW BRANCH CIRCUITS SHALL HAVE SEPARATE NEUTRAL CONDUCTORS. CONDUCTOR SIZE ON FLOOR PLAN MAY CONFLICT WITH CONDUCTOR SIZES IN SCHEDULE. CONDUCTOR SIZES LISTED ON FLOOR PLAN HAVE BEEN UPSIZED FOR VOLTAGE DROP AS REQUIRED. IN ALL CASES, THE LARGER SIZE CONDUCTOR SHALL BE UTILIZED. ALL DEVICES LOCATED WITHIN WASH-DOWN AREAS, INCLUDING BUT NOT LIMITED TO, WALK-IN COOLERS, FREEZERS, SCULLERY, ETC., SHALL UTILIZE PVC CONDUIT, PVC BOXES WITH WEATHERPROOF IN-USE COVERS. ELEVATION DIMENSIONS SHOWN FOR OUTLET BOXES, ENCLOSURES, TV BOXES ETC, ARE TO THE BOTTOM OF THE DEVICE UNLESS OTHERWISE NOTED. ALL CONVENIENCE OUTLETS SHALL BE INSTALLED AT 16” TO THE BOTTOM OF THE DEVICE UNLESS NOTED OTHERWISE. CORD DROPS (AT WORK AREAS) ARE TO BE GATHERED INTO ONE LOCATION (WHERE POSSIBLE), BUNDLED, DROPPED TO FLOOR, AND REDISTRIBUTED UNDER CABINETS TO EQUIPMENT. KELLEM GRIPS SHALL BE USED ON ALL CORD DROPS ORIGINATING AT FACE OF BUS PLUG, RECEPTACLE OR FROM JUNCTION BOX ABOVE EQUIPMENT. ALL CONVENIENCE RECEPTACLES WITHIN CABINETRY SHALL BE 120V, 20A, SPECIFICATION GRADE. BROWN IN COLOR, RAISED COVER DEVICE PLATE. ABOVE COUNTER CONVENIENCE RECEPTACLES SHALL BE IVORY WITH AN IVORY DEVICE PLATE. ALL DEVICE PLATES SHALL BE LABELED WITH CIRCUIT AND PANEL SOURCE. ALL CORDS ARE BLACK IN COLOR AND TYPE SJOOW. LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT SHALL NOT BE RUN IN DISTANCES IN EXCESS OF 6'. ALL CORD DROPS SHALL BE SUPPORTED NEAR SUPPLY RECEPTACLES OR BUS DUCT SWITCHES, PROPERLY SIZED AND OF SUFFICIENT LENGTH. EQUIPMENT CORD DROPS SHALL NOT HAVE A HORIZONTAL DISTANCE GREATER THAN 10'. WHERE DROPS ARE FURTHER THAN 10' FROM ORIGIN, CIRCUIT SHALL BE RUN IN EMT CONDUIT FROM SOURCE TO AREA ABOVE EQUIPMENT. ALL RECEPTACLES FED FROM UPS PANEL SHALL BE BLUE IN COLOR AND MARKED "COMPUTER ONLY". ALL RECEPTACLES FED FROM GENERATOR PANEL SHALL BE BROWN OR IVORY IN COLOR WITH RED PLATE MARKED "EMERGENCY POWER". PROVIDE GFCI PROTECTION FOR ALL 15A OR 20A 125V RECEPTACLES IN KITCHEN AREAS. ALL WIRING DEVICE ELEVATIONS SHOWN ARE TO THE BOTTOM OF THE DEVICE. ELECTRICAL DEMOLITION GENERAL WORK NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. DESIGN IS BASED ON ASSUMPTION THAT THE EXISTING BRANCH CIRCUITING UTILIZES MULTIPLE CONDUCTOR CABLES THAT SERVE MORE THAN ONE (1) CIRCUIT WITH ONE NEUTRAL CONDUCTOR AND WHERE THE CIRCUIT BREAKERS ARE NOT TIED TOGETHER TO TRIP SIMULTANEOUSLY. THIS TYPE OF BRANCH CIRCUITING IS A NEC CODE VIOLATION. ALL EXISTING CIRCUITING THAT IS PART OF THIS REMODEL AND UTILIZES THIS TYPE OF CIRCUITING SHALL BE REMOVED AND REPLACED WITH CODE COMPLIANT BRANCH CIRCUITING. PROVIDE ACCURATE AS-BUILT DOCUMENTATION AND UPDATE PANELBOARD SCHEDULES AS REQUIRED. ELECTRICAL DEMOLITION DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL INTENT AND SCOPE. EXISTING CIRCUITS MUST BE IDENTIFIED AND THE ENERGY SOURCE ISOLATED MAKING THE EQUIPMENT AND/OR SUPPLY RECEPTACLES INOPERABLE PRIOR TO PERFORMING ANY ELECTRICAL DEMOLITION AS PER BILLITIER ELECTRIC'S LOCK OUT TAG OUT PROGRAM. ONLY PROPERLY TRAINED AUTHORIZED INDIVIDUALS MAY ISOLATE THE POWER SOURCE. EXISTING SPARE CIRCUITS INCLUDING CONDUIT, CONDUCTORS, WIRING DEVICES OR CORD DROPS MAY BE RE-USED IF THEY ARE DEEMED TO BE IN GOOD CONDITION AND OF ADEQUATE SIZE AND QUANTITY FOR A CODE COMPLIANT INSTALLATION. ALL EQUIPMENT AND MATERIAL REMOVED SHALL BE HANDED OVER TO THE CUSTOMER. ALL MATERIAL THAT IS TO BE DISPOSED OF SHALL BE DONE SO AT THE CUSTOMER'S REQUEST. CONTINUITY OF "EXISTING TO REMAIN" ELECTRICAL CIRCUITS AND DEVICES SHALL BE MAINTAINED. IDENTIFY CIRCUITING FOR ALL EQUIPMENT THAT IS TO BE REMOVED OR RELOCATED: • IF REQUIRED BY KEYNOTE, DISCONNECT POWER AND REMOVE CONDUITS AND CONDUCTORS BACK TO SOURCE. COMPLETELY REMOVE ASSOCIATED BOXES, WIRING DEVICES, AND/OR CORD DROPS. BRANCH CIRCUITING SHALL NOT BE ABANDONED IN PLACE. • IF REQUIRED BY KEYNOTE, DISCONNECT CIRCUITING AND PULL BACK/RELOCATE TO A SAFE LOCATION DURING DEMOLITION AND LABEL WITH SOURCE. ALL REMOVED CORD DROPS SHALL BE RETURNED TO OWNER FOR FUTURE USE. DEMOLITION WORK KEYED NOTES: 1. 2. 3. DISCONENCT AND REMOVE ENTIRE CORD DROP ASSEMBLY AND BRANCH CIRCUITING BACK TO SOURCE. MAKE BREAKER SPARE. DISCONNECT AND REMOVE ENTIRE CORD DROP ASSEMBLY AND BRANCH CIRCUITING TO ALLOW FOR RELOCATION OF EQUIPMENT. RETAIN ONLY BRANCH CIRCUIT FOR REUSE. DISCONNECT AND REMOVE SCALE RECEPTACLE TO ALLOW FOR RELOCATION OF SCALE. RETAIN ONLY BRANCH CIRCUIT FOR REUSE. ## 1/4" = 1'-0"1 POWER PLAN-DEMO - CHEESE 1/4" = 1'-0"2 POWER PLAN-NEW - CHEESE Revision Schedule # Date Revision 0 7/3/19 071 ELC 044 TRACKING #071-5266 BUSDUCT P1 100ABUSDUCTMC1 100ATAPTAP5 5 6 6 E.4 CAS0391 2B-7 CAS0391 2B-4 CAS0391 2B-5 CAS0391 2B-6 LV6A-4 (2)#10,#10EG LV6A-6 (2)#10,#10EG 1 1 1 1 KEY PLAN Bengineering, p.c.EC Phone: (585) 641-7121 Fax: (585) 362-4175 www.ec4b.com 15 Schoen Place Suite 300 Pittsford, NY 14534 DESIGN / BUILD CONTRACTOR760 BROOKS AVE ROCHESTER NY 14619PHONE 585-224-1111 FAX 585-434-3850billitierelectric.comBILLITIERELECTRICN Project No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.SCALE:AS NOTEDStore No: PRICING SET: PERMIT SET: CONST SET: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209.7/1/2019 11:52:28 AMC:\Users\adetorio\Documents\071 _Ithaca_ELECT_CENTRAL_2017_adetorioM3H83.rvtITHACA, NYER302OLDE WORLD CHEESE REMODEL071-52666/26/2019KAFAED500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/19 TBD REFRIGERATION BRANCH WIRING PLAN - NEWCONSTRUCTION WORK KEYED NOTES: 1.PROVIDE COMPLETE CONNECTION TO NEW CASE LIGHTS, EVAPORATOR FAN, ANTI-SWEATS AND CASE CONTROLS. HOMERUN TO PANELBOARD AS INDICATED. UTILIZE EXISTING SPARE CIRCUIT BREAKER. REFRIGERATION CONSTRUCTION GENERAL WORK NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. DESIGN IS BASED ON ASSUMPTION THAT THE EXISTING BRANCH CIRCUITING UTILIZES MULTIPLE CONDUCTOR CABLES THAT SERVE MORE THAN ONE (1) CIRCUIT WITH ONE NEUTRAL CONDUCTOR AND WHERE THE CIRCUIT BREAKERS ARE NOT TIED TOGETHER TO TRIP SIMULTANEOUSLY. THIS TYPE OF BRANCH CIRCUITING IS A NEC CODE VIOLATION. ALL EXISTING CIRCUITING THAT IS PART OF THIS REMODEL AND UTILIZES THIS TYPE OF CIRCUITING SHALL BE REMOVED AND REPLACED WITH CODE COMPLIANT BRANCH CIRCUITING. USING ADHESIVE BACKED PRINTED TAPE, LABEL ALL RECEPTACLES, SWITCHPLATES AND EQUIPMENT. LABELS SHALL LIST PANEL DESIGNATION AND CIRCUIT NUMBER. TAPE SHALL BE ATTACHED TO FACE OF RECEPTACLE OR EQUIPMENT. ALL AFFECTED PANEL SCHEDULES SHALL BE UPDATED UPON COMPLETION OF PROJECT. PROVIDE AS BUILT DOCUMENTATION ACCURATELY SHOWING WHICH PANEL AND CIRCUIT EACH PIECE OF EQUIPMENT WAS FED FROM. IF REQUIRED, PROVIDE NEW CIRCUIT BREAKERS AND/OR BUSDUCT CIRCUIT BREAKER ENCLOSURES TO MATCH EXISTING MANUFACTURER CONSTRUCTION, KAIC RATING. NEW BREAKERS SHALL BE LISTED FOR USE WITH THE EXISTING PANELBOARD AND/OR BUSDUCT. MINIMUM CONDUCTOR SIZE SHALL BE (2)#12,(1)#12GND UNLESS NOTED OTHERWISE. ALL BRANCH CIRCUIT HOMERUNS (FROM EQUIPMENT/DEVICE TO PANELBOARD) SHALL BE UP-SIZED PER NEC IF DISTANCE EXCEEDS 100' FOR 120V CIRCUITS, 200' FOR 208V CIRCUITS. MAXIMUM ALLOWABLE VOLTAGE DROP FOR A BRANCH CIRCUIT IS 3 PERCENT. ALL NEW 120V AND/OR 277V, 1-PHASE BRANCH CIRCUITS SHALL HAVE SEPARATE NEUTRAL CONDUCTORS. ALL DEVICES LOCATED WITHIN WASH-DOWN AREAS, INCLUDING BUT NOT LIMITED TO, WALK-IN COOLERS, FREEZERS, SCULLERY, ETC., SHALL UTILIZE PVC CONDUIT, PVC BOXES WITH WEATHERPROOF IN-USE COVERS. REFER TO MECHANICAL ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. REFER CPC CONTROL WIRING DETAILS ON MECHANICAL DRAW INGS. FOR NETWORK CABLING USE CONTINUOUS BELDEN 8761 OR EQUAL. DO NOT SPLICE WIRING. SHEILDS TO BE GROUNDED AT THE CASE OR COOLER CONTROLLER END. USE SPADE LUGS FOR CONNECTION TO POINTS ON CONTROLLER EXPANSION BOARDS. PROVIDE NEW OR RE-USE SOLENOID VALVE OUTPUT CABLING AS SHOWN ON THE MECHANICAL DRAWINGS ALL CPC PRODUCTS AND ALL SYSTEM PROGRAMMING PROVIDED BY OTHERS. CASE CONTROL LINK NETWORK CABLING TO BE DAISY CHAIN WIRED TO EACH CONTROLLER. SET TERMINATION JUMPERS ON LAST DEVICE AS SHOWN ON MECHANICAL DRAWINGS. REFRIGERATION CONTROLS CABLING AND TERMINATIONS TO BE FURNISHED AND INSTALLED BY THE E.C. ALL ASSOCIATED WIRING DETAILS ARE PROVIDED BY THE MECHANICAL ENGINEER VIA CONSTRUCTION DRAWINGS. PROVIDE 120V, 1-PHASE CONNECTION TO ALL CASE CONTROL LINKS. UTILIZE CASE POWER CIRCUIT. WHERE APPLICABLE, UTILIZE SPLIT DUCT UTILITY CHASE FOR POWER AND CONTROL WIRING TO CASES. # 1/8" = 1'-0"1 REFRIGERATION PLAN-NEW - CHEESE Revision Schedule # Date Revision 0 7/3/19 071 ELC 044 TRACKING #071-5266 PANEL: LV6A VOLTAGE: 208Y/120 LOCATION: POWERHOUSE "B" PHASE: 3 FED FROM: LV6 WIRE: 4 UL LISTED EQUIPMENT SHORT CIRCUIT RATING: 10 KAIC MAIN BUS AMPS: 225A MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT: MAIN CIRCUIT BREAKER: MLO PHASE CONDUCTOR: 3#250 MCM MOUNTING: SURFACE NEUTRAL CONDUCTOR: 1#250 MCM FEED:BOTTOM ELECTRICAL GROUND CONDUCTOR: 1#2 FEED-THRU LUGS: TOP PHASE AMPS BREAKER BREAKER PHASE AMPS LOAD DESCRIPTION AND LOCATION PH. A PH. B PH. C POLES AMPS CKT. PHASE CKT. AMPS POLES PH. A PH. B PH. C LOAD DESCRIPTION AND LOCATION RECEPTACLE - PHARMACY AREA 1 20 1 A 2 20 1 RADIANT HEATER CNTRL PANEL - WINDSCREEN RECEPTACLE - PHARMACY AREA 1 20 3 B 4 20 1 3.2 LT/EF/AS-CHEESE (2B-4,5) RECEPTACLE - PHARMACY AREA 2 20 5 C 6 20 1 3.2 LT/EF/AS-CHEESE (2B-6,7) 7 A 8 20 1 FANS (1B-10) - DELI BACKBAR CASES SPARE 1 20 9 B 10 20 1 LIGHTS - NEWSPAPERS, DELI BACKBAR SPARE 1 20 11 C 12 20 1 PLUGMOLD - DELI BACKBAR CASES REFRIGERATOR - DELI STORGE 1 20 13 A 14 15* 1 SCALES - DELI REFRIGERATOR - DELI STORGE 1 20 15 B 16 20 1 FANS/AS (1B-8,16,17) DELI CASES RECEPTACLE - WRAPPER DELI STORAGE 1 20 17 C 18 20 1 LIGHTS (1B-8,16,17) DELI CASES CEILING RECEPTACLE - CHEESE 1 20 19 A 20 20 1 SLICERS - DELI FANS (2B-29)1 20 21 B 22 20 1 SLICERS - DELI LIGHTS (2B-29)1 20 23 C 24 20 1 WRAPPER, TAK-A-CHECK, BUG ZAPPER LIGHTS & FANS (2C-7)(2A-50)1 20 25 A 26 20 1 SLICER - DELI AS (2C-7)1 20 27 B 28 20 1 RECEPTACLE, WAPPER - DELI AS (2A-50)1 20 29 C 30 20 1 FANS/AS - BAKERY DEFROST (2A-50)3 20 31 A 32 20 1 LIGHTS - BAKERY 33 B 34 20 1 LIGTHS & FANS (2A-49) 35 C 36 20 1 AS (2A-49) DEFROST (2A-50)3 20 37 A 38 20 3 DEFROST (2A-50)39 B 40 41 C 42 TOTAL AMPS 0 0 0 0 3.2 3.2 TOTAL AMPS Ithaca #071 PH. A PH. B PH. C NOTES: TOTAL PHASE AMPS 0 3.2 3.2 * - GFCI TYPE CIRCUIT BREAKER TOTAL PHASE KVA 0.00 0.89 0.89 ** - PROVIDE ADDITIONAL SPARE CIRCUIT BREAKER, SHIP LOOSE TOTAL 3-PHASE KVA 1.77 *** - PROVIDE BREAKER HANDLE LOCK WITH PADLOCKING PROVISION Revised: 6/5/2019 BUS DUCT - MC1 BUSDUCT LOCATION: CHEESE BUSDUCT RATING: 100A STORE: ITHACA #071 BUS PLUG BREAKERS LOAD DESCRIPTION BUS PLUG BREAKERS LOAD DESCRIPTION POLES SIZE LOAD POLES SIZE LOAD 1 A 20 11 A 20 B 20 B 20 C 20 C 20 2 A 20 12 A 20 B 20 B 20 C 20 C 20 3 A 20 0 SPARE 13 A 20 B 30 0 SPARE B 20 C 30 0 SPARE C 20 4 A 20 2 CHEESE AFFINAGE CASE 14 A 20 B 20 2 CHEESE AFFINAGE CASE B 20 C 20 10.5 4' SELF CONTAINED CASE (10-CAS0239)C 20 5 A 20 15 A 20 B 20 B 20 C 20 C 20 6 A 20 16 A 20 B 20 B 20 C 20 C 20 7 A 20 5 STANDUP WRAPPER (10-WPR0002) 17 A 20 B 20 0 SPARE B 20 C 20 C 20 8 A 20 18 A 20 B 20 B 20 C 20 C 20 9 A 20 19 A 20 B 20 B 20 C 20 C 20 10 A 20 20 A 20 0 SPARE B 20 B 20 0 SPARE C 20 C 20 2.3 CTB SERIES COUNTER TOP COOLER NOTES:PH.A PH.B PH.C * GFCI TYPE CIRCUIT BREAKER TOTAL PHASE AMPS 7 2 12.8 **GFEP TYPE CIRCUIT BREAKER TOTAL PHASE KVA 0.84 0.24 1.54 TOTAL 3-PHASE KVA 2.62 REVISED:6/5/2019 EQUIP. NO. QTY DESCRIPTION/MANUFACTURER VOLT PH. LOAD NO. OF WIRES SIZE & MIN. BKR. SIZE WALL MTD RECEPT. CORD DROP CONNECTIONS PERMITTED REF. NOTES SUPPLY SIDE CORD DROP CONFIGURATION LOAD SIDE CONFIGURATION TWISTLOCK RECEPT PLUG @ TWISTLOCK RECEPT CORD CONNECTOR DROP CORD SIZE/TYPE DROP CORD LENGTH PLUG CORD SIZE/TYPE CORD LENGTH 10 - CHEESE 10-SCL0067 2 SCALE METTLER/TOLEDO #IMPACT M 120 1 11A 2#12 #12EG 15/1 L5-15R L5-15R L5-15P 5-15C 12/3C SJOOW 15'1 10-WPR0002 1 STANDUP WRAPPER HEAT SEALING #112A 120 1 5A 2#12 #12EG 20/1 L5-20R L5-20R L5-20P 5-20C 12/3C SJOOW 15'1 10-CTB CASE 3 COUNTER TOP COOLER AHT #CTB-100 120 1 2.3A 2#12 #12EG 20/1 L5-20R L5-20R L5-20P 5-20C 12/3C SJOOW 15'1 GENERAL NOTES A. ALL CORDS SHALL BE BLACK IN COLOR AND TYPE SJOOW UNLESS OTHERWISE SPECIFIED. B. ALL WIRING DEVICES ARE TO BE BY SAME MANUFACTURER. (MAKE: HUBBELL, PASS AND SEYMOUR) C. REFER TO 'TYPICAL OWNER EQUIPMENT CORD CONNECTION' DETAIL. THIS DETAIL IS INTENDED AS A STANDARD LAYOUT FOR ALL CORD CONNECTED EQUIPMENT. ELECTRICAL CONTRACTOR TO VERIFY MOST APPROPRIATE METHOD OF CONNECTION FOR EACH PIECE OF EQUIPMENT PRIOR TO INSTALLATION. D.FOR CORD DROPS, PROVIDE TWISTLOCK RECEPTACLE MOUNTED TO BAR JOIST, CABLE TRAY, STRUT OR MECHANICAL PIPING SUPPORT SYSTEM, WHICHEVER IS AT LOWEST ELEVATION UNLESS OTHERWISE NOTED. E.ALL CORD DROPS SHALL BE SUPPORTED NEAR SUPPLY RECEPTACLES OR BUS DUCT SWITCHES, PROPERLY SIZED AND OF SUFFICIENT LENGTH. EQUIPMENT CORD DROPS SHALL NOT HAVE A HORIZONTAL DISTANCE GREATER THAN 10'. WHERE DROPS ARE FURTHER THAN 10' FROM ORIGIN, CIRCUIT SHALL BE RUN IN EMT CONDUIT FROM SOURCE TO AREA ABOVE EQUIPMENT. F.KELLEM GRIPS SHALL BE USED ON ALL CORD DROPS ORIGINATING AT FACE OF BUS PLUG, RECEPTACLE OR FROM JUNCTION BOX ABOVE EQUIPMENT. REFERENCE NOTES 1. EQUIPMENT SUPPLIED WITH CORD AND PLUG. PUSHBUTTON STATION BRANCH CIRCUIT PANEL: 208Y/120V, 3 PHASE, 4 WIRE BRANCH CIRCUIT PANEL: 480Y/277V, 3 PHASE, 4 WIRE DOUBLE DUPLEX RECEPTACLE LOW VOLTAGE TRANSFORMER LOCKABLE MANUAL MOTOR SWITCH. REFER TO GENERAL NOTE 'C'. FUSIBLE DISCONNECT SWITCH. REFER TO GENERAL NOTE 'C'. SINGLE RECEPTACLE CORD REEL: 120V, 12/3C, 50' W/ BALL STOP (WOODHEAD, MCGILL #92433 W/ BALL STOP, OR APPROVED EQUAL) POWER/TELECOMM POLE: EZ-POLE, KNOCKOUTS AT BOTTOM OF POLE (SEE DETAILS THIS SHEET) GANGED COMBINATION CCTV OUTLET/DUPLEX RECEPTACLE W/ BARRIER. "WP" INDICATES WEATHERPROOF. REFER TO SPECIAL SYSTEMS PLANS. CORD DROP WITH DEVICE & CABLE. TYPE AS NOTED. DUPLEX RECEPTACLE, 120V, STANDARD 18" AFF TO CENTER UNLESS NOTED OTHERWISE. SUBSCRIPTS INDICATE (TYPICAL FOR ALL RECEPTACLE TYPES): 46" - HEIGHT OF RECEPTACLE TO CENTER ABOVE FINISHED FLOOR GFI - INDICATES GROUND FAULT INTERRUPT C - INDICATES CEILING FLUSH MTD TP - TAMPER PROOF WP - INDICATES WEATHERPROOF COVER UPS - INDICATES UPS FEED GEN - INDICATES GENERATOR FEED (RECEPTACLE TO BE LABELED) CAB - INDICATES INSTALLED WITHIN CABINETRY USE - INDICATES WET LOCATION IN-USE COVER SRG - INDICATES SURGE SUPPRESION WITH LIGHT AND ALARM 20A SIMPLEX RECEPTACLE CAB - INSTALLED WITHIN CABINET 15A SIMPLEX RECEPTACLE CAB - INSTALLED WITHIN CABINETRY EQUIPMENT DESIGNATION PLUGMOLD - PRE-WIRED MULTIOUTLET SYSTEM WITH OUTLETS 18" ON CENTER UNLESS OTHERWISE NOTED. HUBBELL SUPER BASE TRAK MULTI - CHANNEL RACEWAY SYSTEM. SPECIAL PURPOSE RECEPTACLE - SEE EQUIPMENT SCHEDULE OR DRAWING NOTE FOR DEVICE CALLOUT CONDUIT HOMERUN TO PANELBOARD (3/4" MINIMUM UNLESS OTHERWISE NOTED) NON-FUSED DISCONECT SWITCH, AUX-INDICATE AUXILARY CONTACT. REFER TO GENERAL NOTE 'C'. COMBINATION MOTOR STARTER. NEMA SIZE NOTED. REFER TO GENERAL NOTE 'C'. EQUIPMENT CONNECTION CORD DROP BUNDLE, COORDINATE EXACT LOCATION WITH OWNER. ALL EQUIPMENT/DEVICES SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. T A. CR AUX 1 LK CAB 46" GFI CD ELECTRICAL SYMBOL LIST SYMBOL DESCRIPTION EQUIPMENT IDENTIFIER: 92-CAS0277 DEPARTMENT NUMBERGENERAL NOTES: CAB TV EMERGENCY STOP BUTTONE JUNCTION BOXJ 15A DUPLEX TWIST-LOCK RECEPTACLE. CAB - INSTALLED WITHIN CABINETCAB DOCK LEVELER PUSH BUTTON CEILING BAR JOIST OR STRUT SYSTEM DROP CORD - SIZE, TYPE, AND LENGTH LISTED IN EQUIPMENT SCHEDULE KELLEM BUS DROP GRIP, UNIVERSAL EYE (SIZE FOR CABLE SIZE, SEE NOTE 2) OWNER FURNISHED EQUIPMENT CORD CONNECTOR LISTED IN EQUIPMENT SCHEDULE PLUG LISTED ON EQUIPMENT SCHEDULE OR SUPPLIED WITH EQUIPMENT KELLEM CABLE STRAIN RELIEF (SIZE FOR CABLE SIZE) KELLEM SAFETY SPRING (SIZE FOR CABLE SIZE, SEE NOTE 2) THREADED ROD, ATTACH TO BUILDING STRUCTURE, OR ATTACH SAFETY STRING TO BAR JOIST OR STRUT (SEE NOTE 1) KELLEM CABLE STRAIN RELIEF (SIZE FOR CABLE SIZE) SUPPLY SIDE TWIST-LOCK RECEPTACLE: (SUPPORT FROM BUILDING STRUCTURE), BAR JOIST, OR STRUT. INSTALL IN LOCATION AS INDICATED ON DRAWING (I.E. CEILING, STRUT, SOFFIT, ETC). USE APPROPRIATE CEILING ATTACHMENT, DEPENDING ON CEILING TYPE ENCOUNTERED (MAY BE GYPSUM BOARD OR T-BAR CEILING). WHERE CABLE LENGTH IS LONGER THAN DISTANCE FROM CEILING, BAR JOIST, OR STRUT MOUNTED TWIST- LOCK RECEPTACLE TO CORD CONNECTOR AT UTILIZATION EQUIPMENT, PROVIDE SAFETY SPRING AND BUS DROP GRIPS TO TAKE UP SLACK CABLE. ATTACH STRAIN RELIEF TO CEILING GRID, STRUCTURAL BEAM, OR STRUT SYSTEM DROP FROM TWIST-LOCK RECEPTACLE AT CEILING OR STRUT USING PLUG LISTED IN EQUIPMENT SCHEDULE NOTES: A. B. Bengineering, p.c.EC Phone: (585) 641-7121 Fax: (585) 362-4175 www.ec4b.com 15 Schoen Place Suite 300 Pittsford, NY 14534 DESIGN / BUILD CONTRACTOR760 BROOKS AVE ROCHESTER NY 14619PHONE 585-224-1111 FAX 585-434-3850billitierelectric.comBILLITIERELECTRICN Project No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.SCALE:AS NOTEDStore No: PRICING SET: PERMIT SET: CONST SET: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209.7/1/2019 11:52:27 AMC:\Users\adetorio\Documents\071 _Ithaca_ELECT_CENTRAL_2017_adetorioM3H83.rvtITHACA, NYER101OLDE WORLD CHEESE REMODEL071-52666/26/2019KAFAED500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/19 TBD SCHEDULES, LEGENDS AND DETAILSNO SCALE4PANELBOARD DIRECTORIES NO SCALE3EQUIPMENT LIST NO SCALE1POWER EQUIPMENT SYMBOLS NO SCALE2OWNER FURNISHED EQUIPMENT CORD DROP Revision Schedule # Date Revision 0 7/3/19 071 ELC 044 TRACKING #071-5266 C O F F E E B E A N C A B I N E T17-DPR003617-DPR003617-DPR00361 7 - D P R 0 0 3 6 0 0 A A B B C C D D E E F F G G H H 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 A.2 A.2 A.3 A.3 A.6 A.6 B.2 B.2 B.3 B.3 B.5 B.5 B.7 B.7 B.9 C.3 C.5C.6 D.1 D.5 D.8 E.3 E.6E.7 F.1 F.2F.3 F.5 F.6F.7F.8 G.1 G.4G.5.1G.5.4G.6 H.1 H.1 0.3 0.3 0.9 0.9 1.21.3 1.51.6 2.3 2.9 2.5 3.1 3.33.4 3.6 4.1 4.2 4.3 4.6 G.5.3G.5.2 6.86.7 6.9 6.5 7.8 W.1 X.3 X.2 X C.7 E.4 Y.1 Y.2 Y.3 Y.4 Z.1 8.6 Bengineering, p.c.EC Phone: (585) 641-7121 Fax: (585) 362-4175 www.ec4b.com 15 Schoen Place Suite 300 Pittsford, NY 14534 DESIGN / BUILD CONTRACTOR760 BROOKS AVE ROCHESTER NY 14619PHONE 585-224-1111 FAX 585-434-3850billitierelectric.comBILLITIERELECTRICN Project No:DRWN BY:Date:CHECKED BY:FOOD MARKETS, INC.SCALE:AS NOTEDStore No: PRICING SET: PERMIT SET: CONST SET: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209.7/1/2019 11:52:27 AMC:\Users\adetorio\Documents\071 _Ithaca_ELECT_CENTRAL_2017_adetorioM3H83.rvtITHACA, NYCR100OLDE WORLD CHEESE REMODEL071-52666/26/2019KAFAED500 S. MEADOW ST.ITHACA, NY 14850071 N/A 07/03/19 TBD COVER SHEET AND ELECTRICAL SPECIFICATIONSCR100 COVER SHEET AND ELECTRICAL SPECIFICATIONS ER101 SCHEDULES, LEGENDS AND DETAILS ER302 REFRIGERATION BRANCH WIRING PLAN - NEW ER501 POWER PLANS - DEMO AND NEW ELECTRICAL DRAWINGS ITHACA #071 500 SOUTH MEADOW DRIVE ITHACA, NEW YORK 14850 OLDE WORLD CHEESE REMODEL 1.THE WORK SHALL CONSIST OF FURNISHING ALL MATERIALS, LABOR, EQUIPMENT, AND APPARATUSES AND PERFORMING ALL OPERATIONS REQUIRED FOR COMPLETE INSTALLATION OF A COMPLETE AND PROPERLY OPERATING ELECTRICAL SYSTEM. 2.THE CONTRACTOR SHALL PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK IS TO BE DONE. FAILURE TO DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. 3.THE DRAWINGS DETERMINE THE GENERAL INTENT OF THE PROJECT. THE CONTRACTOR SHALL PERSONALLY VISIT THE SITE OF THE PROPOSED WORK AND FULLY DETERMINE THE EXACT LOCATIONS OF EXISTING EQUIPMENT TO BE RE-USED AND RELOCATED, AVAILABILITY OF EXISTING CIRCUIT BREAKERS IN EXISTING PANELBOARDS OR BUSDUCTS, QUANTITY AND LOCATION OF EXISTING CORD DROPS AND EQUIPMENT DROPS, ETC. 4.PANELBOARD AND BUSDUCT SCHEDULES USED IN DESIGN OF NEW LAYOUT MAY NOT BE ACCURATE; TERMINATE AT PANELBOARD OR BUSDUCT CIRCUIT BREAKERS AS REQUIRED BASED ON EXISTING CONDITIONS TO MEET INTENT OF PLANS. EXISTING PANELBOARDS AND BUSDUCTS ARE ASSUMED TO HAVE SUFFICIENT CAPACITY AND POLE SPACE TO ACCOMMODATE PROJECT SCOPE; CONTACT OWNER IMMEDIATELY WITH ANY PANELBOARD OR BUSDUCT CONCERNS. 5.ALL MATERIAL AND APPARATUS SHALL BE NEW AND IN FIRST CLASS CONDITION. ALL MATERIALS AND EQUIPMENT SHALL BE OF COMMERCIAL SPECIFICATION GRADE IN QUALITY. MATERIAL AND EQUIPMENT SHALL BE STORED AND MAINTAINED IN CLEAN CONDITION, AND PROTECTED FROM WEATHER, MOISTURE, AND PHYSICAL DAMAGE. ALL HOISTS, SCAFFOLDS, TOOLS, MACHINERY, EQUIPMENT, ETC. REQUIRED FOR THE PERFORMANCE OF THE ELECTRICAL WORK SHALL BE FURNISHED BY CONTRACTOR. 6.THE CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER CONTRACTORS SO THAT VARIOUS COMPONENTS OF THE ELECTRICAL SYSTEMS WILL BE INSTALLED AT THE PROPER TIME, WILL FIT THE AVAILABLE SPACE AND WILL ALLOW PROPER SERVICE ACCESS TO ALL EQUIPMENT. 7.CONTRACTOR'S PERFORMANCE, WORKMANSHIP AND MATERIALS SHALL COMPLY WITH THE NATIONAL FIRE PROTECTION ASSOCIATION CODES, NATIONAL ELECTRICAL CODE, STATE AND LOCAL BUILDING CODES, AND/OR ALL OTHER APPLICABLE CODES AND ORDINANCES. OBTAIN AND PAY FOR ALL PERMITS, LICENSES, AND/OR BONDS. OBTAIN LOCAL ELECTRICAL INSPECTION CERTIFICATE AND DELIVER TO OWNER. ALL NEW PANELBOARDS, BUSDUCTS AND DISCONNECTS SHALL HAVE PROPER LABELING WARNING OF ELECTRIC SHOCK AND ARC FLASH HAZARDS. 8.SUBMIT FOR APPROVAL THREE SETS OF MANUFACTURER'S SHOP DRAWINGS OF ALL MAJOR ITEMS OF EQUIPMENT. 9.THIS CONTRACTOR SHALL DO ALL CUTTING OF WALLS, CEILINGS, ETC., AS REQUIRED TO INSTALL WORK UNDER THIS SECTION. ALL HOLES SHALL BE CUT AS SMALL AS POSSIBLE. ALL PATCHING SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION. SEAL ALL PENETRATIONS TO RESTORE THE FIRE AND SMOKE RATING OF WALLS, CEILINGS, ETC. ALL ROOF PENETRATIONS TO BE PROVIDED BY OTHERS. 10.ALL CONDUIT RUN UNDERGROUND, EXPOSED TO WEATHER, OR OTHER HAZARDOUS CONDITIONS SHALL BE RIGID OR PVC. ALL OTHER CONDUIT MAY BE EMT WHERE APPROVED BY LOCAL CODE. FINAL CONNECTION TO EACH MOTOR AND TRANSFORMER, AND TO ANY DEVICE WHICH WOULD OTHERWISE TRANSMIT MOTION, VIBRATION OR NOISE, SHALL BE IN FLEXIBLE METAL CONDUIT. WHERE FLEXIBLE METAL CONDUIT IS EXPOSED TO LIQUIDS, VAPORS OR SUNLIGHT, LIQUID-TIGHT FLEXIBLE METAL CONDUIT SHALL BE USED. ALL FLEXIBLE METAL CONDUITS SHALL BE PROVIDED WITH AN INSULATED GROUND WIRE. 11.CONDUIT, MINIMUM OF 3/4", SHALL BE INSTALLED CONCEALED ABOVE CEILINGS OR CONCEALED IN WALLS OR FLOORS WHEREVER POSSIBLE. RUN PARALLEL TO BUILDING LINES. EXISTING CONDUIT MAY BE RE-USED WHERE IN GOOD CONDITION. CONDUITS SHALL BE SECURELY FASTENED IN PLACE WITH APPROVED STRAPS, HANGERS AND STEEL SUPPORTS AS REQUIRED. 12.ALL WIRE SHALL HAVE COPPER CONDUCTORS, WITH UL LABEL, AND 600 VOLT THHN/THWN INSULATION, MINIMUM #12 GAUGE UNLESS OTHERWISE NOTED, WITH EXCEPTION OF CONTROL WIRING. ALL WIRE SHALL BE RUN IN CONDUIT, APPROVED RACEWAYS, AND ENCLOSURES. WHERE PERMITTED BY CODE, METAL CLAD, TYPE MC, CABLE MAY BE USED; ALUMINUM CONDUCTORS ARE NOT PERMITTED. ALL BRANCH CIRCUITS SHALL HAVE AN EQUIPMENT GROUND CONDUCTOR INSTALLED IN THE BRANCH CIRCUIT RACEWAY, SIZED IN ACCORDANCE WITH NEC TABLE 250-122. PROVIDE CONDUCTORS CONTINUOUS BETWEEN OUTLETS OR JUNCTION BOX; DO NOT MAKE SPLICES EXCEPT IN OUTLET BOXES, PULLBOXES, OR PANELBOARD GUTTERS. CORD DROP CABLE TO BE COPPER CONDUCTORS, 60 DEGREE C POLYTHYLENE INSULATION, WITH OVERALL JACKET RATED 600 VOLT AND GREEN CONDUCTOR FOR GROUND. PROVIDE KELLUM GRIP TO LIMIT STRAIN CONNECTION TO JUNCTION BOX. DIVISION 16 - ELECTRICAL 13.VOLTAGE DROP IN BRANCH CIRCUITS SHALL NOT EXCEED 3%. INCREASE WIRE SIZE AS REQUIRED. 14.ALL OUTLETS BOXES FOR LIGHT SWITCH, RECEPTACLE, AND SIMILAR OUTLETS, SHALL BE SIZED ACCORDING TO THE NATIONAL ELECTRICAL CODE. GALVANIZED STEEL KNOCKOUT BOXES, SUITABLE IN DESIGN TO THE PURPOSE THEY SERVE. APPLETON, STEEL CITY, RACO OR APPROVED EQUAL MANUFACTURER. 15.ALL TRANSFORMERS, CONDUCTORS, CONDUITS, MOTOR FRAMES, ETC.. WHICH REQUIRE GROUNDING SHALL BE PERMANENTLY AND EFFECTIVELY GROUNDED BY THE CONTRACTOR IN A THOROUGH AND EFFICIENT MANNER IN CONFORMANCE TO THE NATIONAL ELECTRICAL CODE. 16.ALL PANELBOARDS AND BUSDUCTS ARE EXISTING. UNLESS OTHERWISE NOTED. PROVIDE CIRCUIT BREAKERS COMPATIBLE WITH EXISTING PANELBOARDS OR BUSDUCTS, AS REQUIRED, FOR COMPLETE INSTALLATION. ALL 2 AND 3 POLE CIRCUIT BREAKERS MUST HAVE A COMMON TRIP. EACH PANEL SHALL CONTAIN A TYPEWRITTEN CARD DIRECTORY INDICATING EXACTLY WHAT EACH CIRCUIT CONTROLS. PLUG-IN TYPE BREAKERS WILL NOT BE ACCEPTABLE. 17.CONTRACTOR SHALL FURNISH AND INSTALL SQUARE D, SIEMENS, CUTLER HAMMER, OR GENERAL ELECTRIC FUSED OR NON-FUSED (AS NOTED OR EQUIPPED) SAFETY SWITCHES WHERE NOT FURNISHED WITH THE STARTING EQUIPMENT, AND ALL OTHER POINTS REQUIRED BY CODE. PROVIDE VIBRATION CONTROLS AND SEISMIC RESTRAINTS FOR ALL ELECTRICAL COMPONENTS AND SYSTEMS AS REQUIRED BY LOCAL CODE. 18.ALL ELECTRICAL DEVICES NOT REQUIRED FOR RE-USE AND/OR RELOCATION ARE TO BE REMOVED AND HANDED OVER TO OWNER. ALL HOLES IN DRYWALL TO BE PATCHED. 19.MAINTAIN A SET OF RECORD DRAWINGS AT THE JOB SITE UPON WHICH ALL CHANGES AND DEVIATIONS FROM THE ORIGINAL LAYOUT SHALL BE RECORDED. SUBMIT TO OWNER PRIOR TO APPLICATION FOR FINAL PAYMENT. 20.PROVIDE ALL SINGLE, DUPLEX AND SPECIAL RECEPTACLES PER PLAN. 21.CLEARLY AND PERMANENTLY MARK EQUIPMENT, DISCONNECT SWITCHES, DEVICE PLATES, AND SIMILAR MATERIALS. TEST COMPLETE ELECTRIC SYSTEM FOR GROUNDS AND SHORT CIRCUITS BEFORE FINAL ACCEPTANCE IN ACCORDANCE WITH CODE. 22.WHEN ENCOUNTERED, PROTECT, BRACE, AND SUPPORT EXISTING ACTIVE GAS, ELECTRIC, WATER, AND OTHER SERVICES WHERE REQUIRED FOR PROPER EXECUTION OF WORK. IF EXISTING ACTIVE SERVICES REQUIRE RELOCATION, MAKE REQUEST IN WRITING FOR DETERMINATION. DO NOT PREVENT OR DISTURB OPERATION OF ACTIVE SERVICES THAT ARE TO REMAIN. REPAIR BROKEN SERVICE AT NO COST TO OWNER. WHERE WORK MAKES TEMPORARY SHUTDOWNS OF SERVICES UNAVOIDABLE, SHUTDOWN AT NIGHT OR AT SUCH TIMES AS APPROVED BY OWNER. ARRANGE TO WORK CONTINUOUSLY, INCLUDING OVERTIME IF REQUIRED, TO ASSURE THAT SERVICES WILL BE SHUTDOWN ONLY DURING TIME ACTUALLY REQUIRED TO MAKE NECESSARY CONNECTIONS TO EXISTING WORK. 23.EXISTING CIRCUITS MUST BE IDENTIFIED AND THE ENERGY SOURCE ISOLATED MAKING THE EQUIPMENT AND/OR SUPPLY RECEPTACLES INOPERABLE PRIOR TO PERFORMING ANY ELECTRICAL DEMOLITION AS PER BILLITIER ELECTRIC'S LOCK OUT TAG OUT PROGRAM. ONLY PROPERLY TRAINED AUTHORIZED INDIVIDUALS MAY ISOLATE THE POWER SOURCE. KEY PLAN AREA OF WORK Revision Schedule # Date Revision 0 7/3/19 071 ELC 044 TRACKING #071-5266 280 East Broad Street TEL: 585.232.5135 Suite 200 www.bergmannpc.com Rochester, NY 14604 Wegmans Remodel Group Code Compliance and Scope Narrative Date: July 03, 2019 Contact: Mike Sorensen / Bryan Thompson Email: msorensen@bergmannpc.com / bthompson@bergmannpc.com Store Address: Ithaca Food Market 500 S. Meadow St. Ithaca, NY 14850 Project Name: Olde World Cheese Remodel Wegmans Department(s) Impacted: Cheese (Dept. 10) Tracking Number: 071-5266 Job Number: 971-38 Reference RBs: 071 INT 405 / ELC 044 / REF 037 / CON 039 / PLM 042 Applicable Code: 2015 International Building Code 2015 International Existing Building Code 2015 International Fire Code 2009 ICC A117.1 Accessible and Usable Buildings and Facilities 2014 National Electrical Code (NFPA 70) 2015 International Mechanical Code 2015 International Plumbing Code Occupancy (Section 309): M – Mercantile Construction Classification: IIB Area of Work: 1000 sq. ft. Scope Narrative: This remodel is to relocate seven (7) self-contained refrigerated cases, two (2) scales, one (1) wrapper and one (1) two-bay sink. Four (4) refrigerated cases to be installed. Floor finishes to be patched/repaired as required. Impact on Circulation/Egress: Circulation changes, minimum egress is maintained or exceeded. Permit: Alteration to the building’s Architectural, Mechanical, Plumbing and Electrical systems trigger the requirement for a permit. 10-CAS0317 1 0 -C A S 0 2 9 8 00-GRD000400-GRD0004 00-GRD000400-GRD0004 10-CAS0298 10-SCL006710-SCL006710-WPR000210-CAB002710-CAB002710-TBL0464 10-CAS023910-TBL046410-TBL046410-TBL04641 0 -T B L 0 4 6 4 10-CAS023910-CAS023910-CAS0299BOUNDARY BOUNDARYBOUNDARYBOUNDARY BOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARY 10-CAS039110-CAS039110-CAS039110-CAS039110-TBL060310-TBL060300-GRD0004 00-GRD0004 10-CAS0317 1 0 -C A S 0 2 9 8 00-GRD000400-GRD0004 00-GRD000400-GRD0004 10-CAS0298 10-SCL006710-SCL006710-TBL070400-GRD000400-GRD000400-GRD0004 00-GRD000400-GRD0004 00-GRD0004 00-GRD000400-GRD0004 00-GRD0004 00-GRD0004 00-GRD0004 00-GRD000410-TBL070410-TBL060310-TBL060310-TBL0464 10-TBL046410-TBL046410-TBL046410-TBL010010-TBL010010-TBL010010-WPR000210-CAB002710-CAB002700-GRD0004 00-GRD0004 BOUNDARY BOUNDARYBOUNDARYBOUNDARY BOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARYBOUNDARY F F 5 5 6 6 E.4 10-TBL005110-CAS030010-CAS030010-SNK005010-TBL005110-TBL010010-TBL010010-TBL0100TRASH BUTCHBLKTABLE36"x48"RECYCLETRASH TRASH TABLEMERCHOPP CTB CASE TABLE12L.F.CHEESE(HSO-6S)(2.5UMA)4L.F.CHEESE(HSO-4S)8L.F.CHEESE4L.F.CHEESE(2.5UMA)AREAOFWORK5' - 7"3'-101/2"4'-01/2"2'-21/2"3' - 5" STORE TO RELOCATE THE FOLLOWING EQUIPMENT, NEW LOCATION SHALL NOT IMPEDED ON EGRESS. (3) CAS0239 (1) CAS0299 (2) CAS0300 SINK TO BE RELOCATED, SEE ENGINEERING DRAWINGS F F 5 5 6 6 E.4 RELOCATED ITEMS NEW ITEMS EXISTING ITEMS DEMOLISHED ITEMS EQUIPMENT LEGEND F F 5 5 6 6 E.4 TABLE MERCHANDISING OPPORTUNITY 10-SNK0050RECYCLETRASH 8L.F.CHEESE(02UM)42"H,7"BASESOLID VIEW SOLID VIEW SOLID VIEW SOLID VIEW SOLID VIEWSOLID VIEW SOLID VIEWSOLID VIEW FINISHEDBACKFINISHEDBACKFINISHEDBACKFINISHEDBACKCTB CASE8L.F.CHEESE(02UM)42"H,7"BASE8L.F.CHEESE(02UM)42"H,7"BASE8L.F.CHEESE(02UM)42"H,7"BASEAREAOFWORKMIN.FOREGRESS3'-0"3'-0" MIN. 4' - 3" PATCH FLOOR AS REQUIRED, FINISH: QT-15 MIN.AISLE5'-0"MIN.3'-0"EQ.EQ. RELOCATED SINK,SEE ENGINEERING DRAWINGS NEW MECH. DROP, FINISH: PT-119 AND P-28. TYP. OF (4) NEW CORNER GUARD, TYP. OF (16) F F 5 5 6 6 E.4 1'-3"SEE ENGINEERING DRAWINGS FOR CASE DRAINS AND POWER 6'-0" MIN. AISLE 14' - 4"6'-5"4'-11"HOLD 8' - 0" ALIGN TYP. NEW CASES 22' - 7" N ProjectNo:DRWNBY:MICHAEL JOHN SORENSEN NY STATE REG.# 033368 Date:CHECKEDBY:FOODMARKETS,INC.SCALE:ASNOTEDStore No: PRICING SET: PERMIT SET: CONST SET:280EastBroadStreetRochester,NewYork14604UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209.7/12/20191:09:00PMC:\RevitProjects\071_5266_Ithaca_ANNO_CENTRAL_v2017_bthompson.rvtITHACA,NY#71A801OLDEWORLDCHEESEREMODEL 071-526607/03/19PERMIT SET 07/03/19 MJSBJT500SMEADOWST.ITHACA,NY14850#071 DEMOLITIONANDNEWEQUIPMENTPLANSSCALE: 1/4" = 1'-0"A801 1 DEMOLITION EQUIPMENT PLAN SCALE: 1/4" = 1'-0"A801 2 NEW EQUIPMENT PLAN AREA OF WORK Revision Schedule #Date Revision 1 07/03/19 PR# 071-5266 2 07/03/19 RB 71-INT-405 PERMIT SET